Ruud Achiever Series Highboy & Lowboy Oil Furnaces with ECM/Variable Speed Motors

Size: px
Start display at page:

Download "Ruud Achiever Series Highboy & Lowboy Oil Furnaces with ECM/Variable Speed Motors"

Transcription

1 THIS MODEL 80.0% 78% 82% 88% 97% Oil Furnaces Ruud Achiever Series Highboy & Lowboy Oil Furnaces with ECM/Variable Speed Motors ROCA-***E: Highboy Series ROLA-***E: Lowboy Series Input Ratio from 84,000 to 175,000 BTU/HR [24.61 to kw] ENER UIDE Annual Fuel Utilization Efficiency - AFUE MID HIGH The Ruud Achiever Series premium upflow oil furnace is for installation in proper ventilated utility rooms, closets or alcoves. ECM blower assemblies for heating and air conditioning applications ECM Control board located in furnace vestibule ECM controls set for 2-stage air conditioning, 2-stage heat pump back up 10-gauge primary and 14-gauge secondary heat exchanger Front cleanout ports extend through front wall for accessibility Efficiencies up to 85.9% Front or rear flue Lowboys available All furnaces have standard Honeywell controls Available with Beckett, Riello Carlin burners Extended vestibule on all units Rely on Ruud. FORM NO. O22-616

2 Table of Contents TABLE OF CONTENTS Standard Equipment...3 Specifications & Dimensions...4 Model Number Identification...5 Blower Performance Data...6 Limited Warranty Rely on Ruud.

3 Standard Equipment STANDARD EQUIPMENT The Ruud Achiever Series Oil Furnace is fully assembled and offers the option of 3 separate burner in a box combinations. Highboy and Lowboy configurations available. Standard Honeywell Controls and barometric draft control. The unit has an extended vestibule to conceal burner and operating controls. A 10-gauge primary and 14-gauge secondary heat exchanger include accessible cleanout ports that extend through the front wall of the furnace enclosure for ease of serviceability. Variable speed ECM motor and control board is engineered to accept 2-stage air conditioning and 2-stage heat pump backup. An external filter and filter rack is included ROCA series furnaces. WARNING THIS FURNACE IS NOT APPROVED OR RECOMMENDED FOR USE IN MOBILE HOMES Rely on Ruud. 3

4 Specifications and Dimensions Specifications and Dimensions ECM Motor FURNACE Furnace Type Lowboy* Highboy Model ROLA-070E ROLA-115E ROCA-070E ROCA-115E DIMENSIONS Cabinet Height (A) 40" 46" 53-5/8" 56-1/2" Cabinet Width (B) 20-1/4" 25-1/8" 22-1/4" 25-1/2" Cabinet Depth (C) 47-1/2" 53-5/8" 33-1/8" 38" Centerline - Flue to Floor (D) 31-1/4" 38-1/2" 49-1/8" 52-5/8" Centerline - Flue to Side (E) 10-1/8" 12-1/2" 11-1/8" 12-3/4" Warm Air Supply Depth (G) 17-1/2" 21-1/2" 19-3/4" 23-3/8" Warm Air Supply Width (Ho) 18-1/4" 22-7/8" 20-1/2" 23-3/4" Return Air Supply Width (Hr) 18-1/4" 22-7/8" 15" 15" Return Air Supply Depth (J) 14" 13-5/8" 23-5/8" 23-5/8" SPECIFICATIONS Flue Size 6" 6" 6" 6" Filter Size 16" x 20" (2) 16" x 20" (2) 16" x 25" 16" x 25" Blower Size T T T T Shipping Weight 323 lbs. 362 lbs. 298 lbs. 347 lbs. B.T.U.H. Input 84, , , , ,000 84, , , , ,000 B.T.U.H. Output 71,000 88,000 99, , ,000 71,000 88,000 99, , ,000 Beckett AFG 100psi A B B B B A B B B B Riello psi A A A B B A A A B B Carlin EZ-1 100psi A A A SS SS A A A SS SS AFUE Seasonal Efficiency 85.9% 85.4% 85.0% 85.0% 84.2% 85.9% 85.4% 85.0% 85.0% 82.3% Blower Motor Drive Direct/ECM Direct/ECM Direct/ECM Direct/ECM Direct/ECM Direct/ECM Direct/ECM Direct/ECM Direct/ECM Direct/ECM Heating Ext. Static Pressure In. [kpa].2 [.05].2 [.05].2 [.05].2 [.05].2 [.05].2 [.05].2 [.05].2 [.05].2 [.05].2 [.05] Max. Ext. Static Pressure In. [kpa].5 [.12].5 [.12].5 [.12].5 [.12].5 [.12].5 [.12].5 [.12].5 [.12].5 [.12].5 [.12] Temperature Rise Range F [ C] [28-42] [28-42] [28-42] [28-42] [28-42] [28-42] [28-42] [28-42] [28-42] [28-42] Blower Motor Full Load Amps Total Current Minimum Circuit Ampacity * Specify front or rear flue on Lowboy models [ ] Designates Metric Conversions Lowboy Highboy 4 Rely on Ruud.

5 Model Number Identification Model Number Identification Highboy and Lowboy Models R O L A 070 E 04 B F Ruud Oil Furnace Type C = Highboy L = Lowboy Design Series [ ] Designates Metric Conversions Heating Input Designation (Output BTU/HR) 070 = 70,000 [20.5 kw] 115 = 115,000 [33.8 kw] Motor Type E = ECM Motor Heating and Cooling Designation 03 = Up to 3 tons cooling CFM for 070 models 04 = Up to 4 tons cooling CFM for 070 models 05 = Up to 5 tons cooling CFM for 115 models Burner Type B = Beckett Burners C = Carlin Burners R = Riello Burners Variations (Applies only to ROLA Models) F = Front Flue R = Rear Flue Rely on Ruud. 5

6 Blower Performance Data Blower Performance Data Highboy and Lowboy Models MODEL LOWBOY HIGHBOY ROLA-070E03 ROLA-070E04 ROLA-115E05 ROCA-070E03 ROCA-070E04 ROCA-115E05 Horsepower/Speed 3/4 HP, Variable Speed Heating CFM Cooling CFM 1-1/2 Tons N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Cooling CFM 2 Tons N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Cooling CFM 2-1/2 Tons N/A N/A N/A N/A Cooling CFM 3 Tons Cooling CFM 3-1/2 Tons N/A N/A N/A N/A N/A N/A Cooling CFM 4 Tons N/A N/A N/A N/A N/A N/A Cooling CFM 5 Tons N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Shipping Weight Rely on Ruud.

7 Limited Warranty GENERAL TERMS OF LIMITED WARRANTY* The Manufacturer will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated here, in accordance with the terms of the limited warranty. *For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate. Oil Heat Exchanger...Limited Lifetime Any Other Part...Five (5) Years Rely on Ruud. 7

8 In keeping with its policy of continuous progress and product improvement, Ruud reserves the right to make changes without notice. Ruud Heating, Cooling & Water Heating P.O. Box Fort Smith, Arkansas Ruud Canada 125 Edgeware Road, Unit 1 Brampton, Ontario L6Y 0P5 PRINTED IN U.S.A 04/12 DC FORM NO. O22-616

Gas Furnaces 95AF2V. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited

Gas Furnaces 95AF2V. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited PRODUCT SPECIFICATIONS INSTALLATION OPTIONS Available in Upflow/Horizontal and Counterflow models HEAT EXCHANGER Aluminized steel primary heat exchanger with crimped non-welded construction Stainless steel

More information

Gas Furnaces 95AF. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited. 95% AFUE 44,000 to 110,000 Btuh Input 2 to 5 Tons Add-On Cooling

Gas Furnaces 95AF. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited. 95% AFUE 44,000 to 110,000 Btuh Input 2 to 5 Tons Add-On Cooling PRODUCT SPECIFICATIONS INSTALLATION OPTIONS Available in Upflow/Horizontal and Counterflow models HEAT EXCHANGER Aluminized steel tapered design primary heat exchanger with crimped construction for long

More information

Field Installed Options: * Louvered or non-louvered ceiling access panels. * Time delay relay.

Field Installed Options: * Louvered or non-louvered ceiling access panels. * Time delay relay. Description: The High Efficiency Series air handlers are engineered to achieve or exceed today s demanding energy rating requirements. Specifically designed for horizontal mounting into a furred down ceiling.

More information

AIR CONDITIONERS WA14**W SERIES

AIR CONDITIONERS WA14**W SERIES FORM NO. A66-225 REV. 3 AIR CONDITIONERS Features Outdoor air conditioner designed for ground level or rooftop installations. These units offer comfort and dependability for single, multi-family and light

More information

AIR CONDITIONERS WA14 SERIES

AIR CONDITIONERS WA14 SERIES FORM NO. A66-220 REV. 3 AIR CONDITIONERS Features Outdoor air conditioner designed for ground level or rooftop installations. These units offer comfort and dependability for single, multi-family and light

More information

COMMERCIAL LOW PROFILE 8 Electric Heated Air Curtain Data Sheet

COMMERCIAL LOW PROFILE 8 Electric Heated Air Curtain Data Sheet For Door Heights To 8 (environmental separation) COMMERCIAL LOW PROFILE 8 Data Sheet STANDARD CONSTRUCTION 8 1/2 high x 13 1/2 deep 1/5 hp two speed motor(s) Factory installed fan speed/heat switch White

More information

MAINLINE MLA14 AIR CONDITIONERS

MAINLINE MLA14 AIR CONDITIONERS FORM NO. AML-220 Supersedes Form No. PTZ-789 MAINLINE AIR CONDITIONERS Efficiencies up to 16 /13 Nominal Sizes 1.5-5 Ton [5.28 TO 17.6 KW] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Manufactured

More information

FMU4X, FMC4X FMU4P, FMC4P

FMU4X, FMC4X FMU4P, FMC4P ENVIRONMENTALLY SOUND REFRIGERANT FMU4X, FMC4X FMU4P, FMC4P Product Specifications HORIZONTAL FAN COILS FMU4P and FMC4P 1 1/2, 2, 2 1/2, and 3 Tons FMU4X and FMC4X 1 1/2, 2 and 2 1/2 Tons ALL MODELS Horizontal

More information

If you want to offer a more professional look to your

If you want to offer a more professional look to your Infrared griddle (optional) Porcelain-coated cast iron top grates Model RT366 Low-profile island trim Dual brass burners Model RT364C Location of rating plate Model RT364G Stainless steel exterior finish

More information

Required Indoor Draft Hood. Optional Outdoor Vent Cap

Required Indoor Draft Hood. Optional Outdoor Vent Cap Pump-Mounted Water Heaters B4 - Copper Brute Water Heater Convertible Sizes 175,000-399,000 BTU/hr Indoor/Outdoor Sizes 500,000-1,825,000 BTU/hr Up to 82% Thermal Efficiency The unit will be designed and

More information

Product Data CAPVP, CARVP, CAPVU, CARVU EVAPORATOR COIL A COIL - CASED AND UNCASED UPFLOW, DOWNFLOW DESIGN FEATURES

Product Data CAPVP, CARVP, CAPVU, CARVU EVAPORATOR COIL A COIL - CASED AND UNCASED UPFLOW, DOWNFLOW DESIGN FEATURES CAPVP, CARVP, CAPVU, CARVU EVAPORATOR COIL A COIL - CASED AND UNCASED UPFLOW, DOWNFLOW Product Data CAPVP / CARVP A06001 A06002 CAPVU / CARVU The CAPVP, CARVP, CAPVU, and CARVU evaporator coils incorporate

More information

XDF BURNERS DUAL FUEL EXCESS AIR BURNER FEATURES DESCRIPTION EXCESS AIR OPERATION

XDF BURNERS DUAL FUEL EXCESS AIR BURNER FEATURES DESCRIPTION EXCESS AIR OPERATION DUAL FUEL EXCESS AIR BURNER MODEL: 3610, 3651 Revision: 0 FEATURES Burns all fuel gases or light oils Nozzle mix design for on ratio control or excess air 350% excess air all sizes on gas or oil Turndown

More information

Instructions for SMV 3000 Multivariable Configuration (MC) Data Sheets

Instructions for SMV 3000 Multivariable Configuration (MC) Data Sheets Instructions for SMV 3000 Multivariable Configuration (MC) Data Sheets Similar to the TC option for ST 3000 transmitters, the MC option for the SMV 3000 provides a service to our customers which results

More information

VARIABLE SPEED AIR CONDITIONERS

VARIABLE SPEED AIR CONDITIONERS FORM NO. AFJ-224 Supersedes Form No. AFJ-222 VARIABLE SPEED AIR CONDITIONERS FO*20C SERIES Efficiencies up to 20 SEER/13 EER Nominal Sizes 2, 3, 4 & 5 Ton [7.03, 10.6, 14.06 & 17.6 kw] Cooling Capacities

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL USER S INFORMATION MANUAL UPFLOW, DOWNFLOW, UPFLOW/HORIZONTAL & HORIZONTAL ONLY INDUCED DRAFT GAS FURNACES Recognize this symbol as an indication of Important Safety Information If the information in this

More information

Models EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations

Models EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations Models EXN and OLG Certified. Not Modified. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations General Description Industrial Climate Engineering s (ICE) EXN and OLG pressurization

More information

ARCHITECTURAL LOW PROFILE 8 Electric Heated Air Curtain Data Sheet

ARCHITECTURAL LOW PROFILE 8 Electric Heated Air Curtain Data Sheet For Mounting Heights To (environmental separation) ARCHITECTURAL LOW PROFILE Electric Heated Air Curtain Data Sheet STANDARD CONSTRUCTION 7 1/2 high x 13 ¾ deep 1/5 hp motor(s) - ten speeds Factory installed

More information

Design Guide /01. ThermAir Burners TA Series version 1.10

Design Guide /01. ThermAir Burners TA Series version 1.10 Design Guide 114 10/01 ThermAir Burners TA Series version 1.10 COPYRIGHT DISCLAIMER NOTICE LIABILITY AND WARRANTY Copyright I998 by Eclipse Combustion, Inc. All rights reserved worldwide. This publication

More information

Product Data CAPMP, CARMP EVAPORATOR COIL A COIL - CASED MULTIPOISE CAPMP / CARMP CAPMP / CARMP (3619, 4823, 6025)

Product Data CAPMP, CARMP EVAPORATOR COIL A COIL - CASED MULTIPOISE CAPMP / CARMP CAPMP / CARMP (3619, 4823, 6025) CAPMP, CARMP EVAPORATOR COIL A COIL - CASED MULTIPOISE Product Data (3619, 4823, 6025) A06009 A07904 The CAPMP and CARMP evaporator coils incorporate proven standards for reliable system operation and

More information

ENGINEERING DATA. Engineering Data

ENGINEERING DATA. Engineering Data ENGINEERING DATA Engeerg Data 599 Average Depth 3.5 ft. ESTIMATING TOTAL GALLONS IN A POOL OR SPA Length 24 ft. Dia. Width Depth (deep) Depth (shallow) Radius 2 x 3.14 x A.D. x 7.5 = Gallons 12 x 12 x

More information

If you want to offer a more professional look to your

If you want to offer a more professional look to your Model RT366 Model RT364C Low profile island trim 11" (279) griddle (optional) Porcelain coated cast iron top grates Dual brass burners 36" GAS RANGETOPS Model RT364G Stainless steel exterior finish Large

More information

MRO Oil-Air Ratio Regulator

MRO Oil-Air Ratio Regulator MRO Oil-Air Ratio Regulator MRO-1 Edition 07-08 Wide capacity range Requires constant oil supply at 45-65 psig (310-450 kpa) Provides automatic and simple method of maintaining air/oil ratio Wide turndown

More information

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to: LOW PRESSURE FILTERS Max Flow: gpm ( lpm) In-Tank Filters Working Pressures to: Rated Static Burst to: psi kpa bar psi kpa bar Flow Range to: gpm lpm Features STYLE C STYLE D STYLE E in-tank filters are

More information

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-220 Supersedes Form No.

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-220 Supersedes Form No. FORM NO. AFJ-220 Supersedes Form No. PTZ-789 AIR CONDITIONERS FO*14C SERIES Efficiencies up to 16 S/13 Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7

More information

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS ACCESSORY KIT INSTALLATION INSTRUCTIONS 1NP0680 - PROPANE CONVERSION FOR USE WITH MODELS: PM8, PC8, PM9, PC9, FL9M, FL9C, FC9M, FC9C This conversion kit is to be installed by a qualified service agency

More information

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-221 Supersedes Form No.

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-221 Supersedes Form No. FORM NO. AFJ-221 Supersedes Form No. PTZ-789 AIR CONDITIONERS FO*13C SERIES Efficiencies 13-15.5 SEER/11.5-13 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7

More information

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS ACCESSORY KIT INSTALLATION INSTRUCTIONS PROPANE CONVERSION - INDUCED COMBUSTION FURNACES 1NP0501 FOR USE WITH 95% MODELS: TG9S, GG9S (130,000 BTU ONLY) FOR USE WITH 80% MODELS: TG(8,L)S, GG(8,L)S (130,000

More information

Product Data. CAPVP, CARVP, CAPVU, CARVU Evaporator Coil A Coil --- Cased and Uncased Upflow, Downflow CAPVP / CARVP

Product Data. CAPVP, CARVP, CAPVU, CARVU Evaporator Coil A Coil --- Cased and Uncased Upflow, Downflow CAPVP / CARVP CAPVP, CARVP, CAPVU, CARVU Evaporator Coil A Coil Cased and Uncased Upflow, Downflow Product Data CAPVP / CARVP A06001 A06002 CAPVU / CARVU The CAPVP, CARVP, CAPVU, and CARVU evaporator coils incorporate

More information

Models EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations

Models EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations Models EXN and OLG Certified. Not Modified. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations General Description Industrial Climate Engineering s (ICE) EXN and OLG pressurization

More information

Additel 780 Series Pressure Controller

Additel 780 Series Pressure Controller Additel 780 Series Pressure Controller Pressure ranges from vacuum to 3,000 psi (200 bar) Removable interchangeable intelligent sensors Precision accuracy of 0.005% of reading plus 0.005% of full scale

More information

Model 26.5 WEAU242AA WEAU244BA 29.0 WEAU242BA 29.0 WEAU304AA 33.0 WEAU302AA WEAU304BA 33.0 WEAU302BA 33.

Model 26.5 WEAU242AA WEAU244BA 29.0 WEAU242BA 29.0 WEAU304AA 33.0 WEAU302AA WEAU304BA 33.0 WEAU302BA 33. EVAPORATOR COILS A COIL UNCASED R 22 or R 410A SYSTEMS 1 5 Tons WEAU Certification applies only when the complete system is listed with ARI ISO 9001:2000 REGISTERED R 410A R 22 Size Shipping Weight Size

More information

Additel 780 Series Pressure Controller

Additel 780 Series Pressure Controller Additel 780 Series Pressure Controller Pressure ranges from vacuum to 3,000 psi (200 bar) Removable interchangeable intelligent sensors Precision accuracy of 0.005% of reading plus 0.005% of full scale

More information

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-222 Supersedes Form No.

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-222 Supersedes Form No. FORM NO. AFJ-222 Supersedes Form No. PTZ-789 AIR CONDITIONERS FO*16C SERIES Efficiencies up to 16 SEER/13 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to

More information

Product Data. CK5A, CK5B, CK5P Furnace N-Coils. Sizes A018 thru A060

Product Data. CK5A, CK5B, CK5P Furnace N-Coils. Sizes A018 thru A060 Product Data CK5A, CK5B, CK5P Furnace N-Coils Sizes A018 thru A060 This vertical design N-coil is a furnace coil designed to provide the highest standards of reliability and durability. The coils are offered

More information

2 are both ways of saying a ratio of 2 to 5

2 are both ways of saying a ratio of 2 to 5 Unit 4 Ratios A Ratio is a comparison of two related quantities. Ratios are expressed in two forms. 2 : 5 or 5 2 are both ways of saying a ratio of 2 to 5 1. Conversion factors are ratios. Express 100

More information

Ruud Achiever Series Heat Pump

Ruud Achiever Series Heat Pump Heat Pumps Ruud Achiever Series Heat Pump RP14**F Series Efficiencies: 14-15 SEER/11.5-12.5 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Proper

More information

MODEL: SA13. Air Conditioners. Sure Comfort SA13. Air Conditioners

MODEL: SA13. Air Conditioners. Sure Comfort SA13. Air Conditioners 15.5 MODEL: SA13 Air Conditioners FORM NO. ASC-221 REV. 1 Sure Comfort SA13 Air Conditioners Efficiencies 13-15.5 S/11.5-13 Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5

More information

Eclipse Extern-A-Therm Recuperators

Eclipse Extern-A-Therm Recuperators Design Guide 540 3/9/2009 Eclipse Extern-A-Therm Recuperators Models 300 MA - 2500 MA Copyright Copyright 2007 by Eclipse, Inc. All rights reserved worldwide. This publication is protected by federal regulation

More information

CASED HORIZONTAL FURNACE COIL. Model CK3B. Form No. SS-CK3B-01 FEATURES

CASED HORIZONTAL FURNACE COIL. Model CK3B. Form No. SS-CK3B-01 FEATURES SIZES AVAILABLE: The horizontal N-Coil is available in six coil sizes (024 through 060). It is designed to provide the highest standard of reliability and durability. CASING: The CK3B coil casing is unpainted

More information

MAINLINE MLP14**A HEAT PUMPS

MAINLINE MLP14**A HEAT PUMPS FORM NO. PML-806 REV. 2 Supersedes Form No. PTZ-789 MAINLINE HEAT PUMPS Efficiencies: 15 SEER/12.5 EER 9 HSPF Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to

More information

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS ACCESSORY KIT INSTALLATION INSTRUCTIONS HIGH ALTITUDE APPLICATION CONVERSION INSTRUCTION HIGH EFFICIENCY GAS FURNACES 1PS0306 / 1PS0307 / 1PS0308 / 1PS0309 / 1PS0901 / 1PS0902 / 1PS0903 FOR USE WITH MODELS:

More information

Base engine for use in U.S., the U.S. Territories, and Canada

Base engine for use in U.S., the U.S. Territories, and Canada 210G / 210G LC 12 13 Engine 210G / 210G LC Base engine for use in U.S., the U.S. Territories, and Canada Optional engine for use outside the U.S. and U.S. Territories Optional engine for use outside the

More information

Propane Conversion Kit Instruction

Propane Conversion Kit Instruction Propane Conversion Kit Instruction Condensing gas boiler Required Input Rates GB142-24 84,800 btu/hr GB142-30 106,000 btu/hr GB142-45 160,900 btu/hr GB142-60 214,800 btu/hr This kit and instructions are

More information

ACCESSORY KIT INSTALLATION MANUAL

ACCESSORY KIT INSTALLATION MANUAL ACCESSORY KIT INSTALLATION MANUAL LP (PROPANE) CONVERSION KIT 1NP0366 FOR USE WITH MODELS: G8C & GF8 This conversion kit shall be installed by a qualified service agency in accordance with these instructions

More information

Eclipse ThermJet Burners for Preheated Combustion Air Models TJ0015 TJ2000

Eclipse ThermJet Burners for Preheated Combustion Air Models TJ0015 TJ2000 Design Guide 206 3/5/07 Eclipse ThermJet Burners for Preheated Combustion Air Models TJ0015 TJ2000 Version 2 Copyright Copyright 2007 by Eclipse, Inc. All rights reserved worldwide. This publication is

More information

D U A L F U E L R A N G E S

D U A L F U E L R A N G E S D U A L F U E L R A N G E S INSTALLATION INSTRUCTIONS C O N TA C T I N F O R M AT I O N Wolf Customer Service: 800-332-9513 Website: wolfappliance.com As you follow these instructions, you will notice

More information

Quiz #1 Thermodynamics Spring, 2018 Closed Book, Open Appendices, Closed Notes, CLOSED CALCULATORS

Quiz #1 Thermodynamics Spring, 2018 Closed Book, Open Appendices, Closed Notes, CLOSED CALCULATORS Quiz #1 Closed Book, Open Appendices, Closed Notes, CLOSED CALCULATORS An astronaut has a mass of 161 lbm on the surface of the earth. Calculate his weight (in lbf) on planet Rigel 4 where g = 20.0 ft/s

More information

Fundamentals of Compressed Air Systems. Pre-Workshop Assignment

Fundamentals of Compressed Air Systems. Pre-Workshop Assignment Page 1 In order to ensure that the Compressed Air Challenge Fundamentals of Compressed Air Systems Training is most useful to you, it will be important for you to bring information about your plant s compressed

More information

Additel 780 Series Pressure Controller

Additel 780 Series Pressure Controller Additel 780 Series Pressure Controller Pressure / Process Calibration Equipment Pressure ranges from vacuum to 3,000 psi (200 bar) Removable interchangeable intelligent sensors Precision accuracy of 0.005%

More information

LENNOX SLP98UHV DIAGNOSTIC CODES

LENNOX SLP98UHV DIAGNOSTIC CODES Code Status of Equipment Action required to clear and recover - Idle mode (Decimal blinks at 1 Hertz -- 0.5 second ON, 0.5 second OFF) A Cubic feet per minute (cfm) setting for indoor blower (1 second

More information

4HP15 PRODUCT SPECIFICATIONS 15 SEER SPLIT SYSTEM HEAT PUMP

4HP15 PRODUCT SPECIFICATIONS 15 SEER SPLIT SYSTEM HEAT PUMP 4HP15 PRODUCT SPECIFICATIONS 15 SPLIT SYSTEM HEAT PUMP FORM NO. 4HP15-100 (12/2017) FEATURES AND BENEFITS R410A Refrigerant High-quality condenser coil with copper tubing and enhanced louvered fin for

More information

IPG IGNITION GAS PILOTS BACK-LOADED GAS

IPG IGNITION GAS PILOTS BACK-LOADED GAS INSTRUCTIONS IPG IGNITION GAS PILOTS BACK-LOADED GAS WARNING These instructions are intended for use only by experienced, qualified combustion start-up personnel. Adjustment of this equipment and its components

More information

FLOMIXERS SELECTION DATA ALL GASES

FLOMIXERS SELECTION DATA ALL GASES MODEL: 2301 Revision: 0 BULLETIN 2301-2311 FLOMIXERS are proportional mixing devices that utilize the energy of a stream of air at pressures up to several pounds to (1) entrain a combustible gas, and (2)

More information

Your safety and the safety of others are very important.

Your safety and the safety of others are very important. NATURAL GAS TO PROPANE CONVERSION KIT ALPKT57- INSTALLATION INSTRUCTIONS PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements... Table of Contents INSTALLATION

More information

Hydraulic lift crane. Complies with ANSI/ASME B 30.5 LR enus LR

Hydraulic lift crane. Complies with ANSI/ASME B 30.5 LR enus LR Hydraulic lift crane LR 1110 Complies with ANSI/ASME B 30.5 enus LR 1001.02 Concept and characteristics LR 1110 Standard Excellent lifting capacities thanks to optimized distribution of forces New cabin

More information

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS ACCESSORY KIT INSTALLATION INSTRUCTIONS PROPANE CONVERSION - INDUCED COMBUSTION FURNACES 1NP0347 FOR USE WITH 90% MODELS: GF9S, GY9S, GM9S, PS9, FL9S, FC9S, PT9, FL9T, FC9T, GM9T, PV9, FL9V, FC9V, GM9V,

More information

Typical Piping Layouts for PREMIX Blower Mixer Systems

Typical Piping Layouts for PREMIX Blower Mixer Systems PREMIX Blower s Page 3103 Block & Bleed system is frequently required by insurance authorities. Typical Piping Layouts for PREMIX Blower Systems Maxon assumes no responsibility for the use or misuse of

More information

CHAPTER 3 : AIR COMPRESSOR

CHAPTER 3 : AIR COMPRESSOR CHAPTER 3 : AIR COMPRESSOR Robotic & Automation Department FACULTY OF MANUFACTURING ENGINEERING, UTeM Learning Objectives Identify types of compressors available Calculate air capacity rating of compressor

More information

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply 4.1.1 General The primary function of a system for handling fuel oil is to transfer oil from the storage tank to the oil burner at specified conditions

More information

Propane Conversion Kit Instruction

Propane Conversion Kit Instruction Propane Conversion Kit Instruction Condensing gas boiler Required Input Rates GB42-24 84,800 btu/hr Tab. GB42-30 06,000 btu/hr GB42-45 49,000 btu/hr GB42-60 24,800 btu/hr This kit and instructions are

More information

TM420SDL - Air Compressor 100 Litre Tank / 3hp 14.6cfm / 416lpm Displacement

TM420SDL - Air Compressor 100 Litre Tank / 3hp 14.6cfm / 416lpm Displacement TM420SDL - Air Compressor 100 Litre Tank / 3hp 14.6cfm / 416lpm Displacement On Sale Ex GST Inc GST $1,260.00 $1,200.00 $1,386.00 $1,320.00 ORDER CODE: MODEL: Drive Type: C505 TM420SDL V-Belt Piston Displacement

More information

ACCESSORY KIT INSTALLATION INSTRUCTIONS PROPANE CONVERSION - INDUCED COMBUSTION FURNACES 1NP0347

ACCESSORY KIT INSTALLATION INSTRUCTIONS PROPANE CONVERSION - INDUCED COMBUSTION FURNACES 1NP0347 ACCESSORY KIT INSTALLATION INSTRUCTIONS PROPANE CONVERSION - INDUCED COMBUSTION FURNACES 1NP0347 FOR USE WITH 90% MODELS: GF9S, GY9S, GM9S, PS9, FL9S, FC9S, PT9, FL9T, FC9T, GM9T, PV9, FL9V, FC9V, GM9V,

More information

GAS SUPPLY APPLICATION GUIDE

GAS SUPPLY APPLICATION GUIDE GAS SUPPLY APPLICATION GUIDE Natural Gas or Propane Modulating & Condensing Boilers and Water Heaters This document applies to the following models: Boilers AM 399B AM 500B AM 750B AM 1000B Gas-Fired Boilers

More information

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners BULLETIN MT2035-07/05 Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners M/MR Series M411, M511, M611 M420, M520, M620, MR410, MR510, MR610 MR212D, MR212E, MR212G and MR212J (Flanged),

More information

WhisperValue DC. The ideal Multi-Family Solution High Performance Built for the Long Run

WhisperValue DC. The ideal Multi-Family Solution High Performance Built for the Long Run WhisperValue DC The ideal Multi-Family Solution High Performance Built for the Long Run The ideal Multi-Family Solution - Cost Efficient Code Compliance Made Easy Though small in size, Panasonic s WhisperValue

More information

TWC Services, Inc. Structured On-The-Job Training for JT- 1, 2, 3

TWC Services, Inc. Structured On-The-Job Training for JT- 1, 2, 3 TWC Services, Inc. Structured On-The-Job Training for JT- 1, 2, 3 The following tasks parallel the Jr. Tech (JT-1, 2, 3) description and development plan and use the Refrigeration and Air conditioning

More information

EXPLOSION PROOF PRESSURE SWITCH MODEL : P953 SERIES

EXPLOSION PROOF PRESSURE SWITCH MODEL : P953 SERIES EXPLOSION PROOF PRESSURE SWITCH MODEL : P953 SERIES SERVICE INTENDED P953 Diaphragm type pressure switch is applied with a variety of process lines. Internal micro switch is operated by pressure of various

More information

ACCESSORY KIT INSTALLATION INSTRUCTIONS PROPANE CONVERSION - INDUCED COMBUSTION FURNACES 1NP0347

ACCESSORY KIT INSTALLATION INSTRUCTIONS PROPANE CONVERSION - INDUCED COMBUSTION FURNACES 1NP0347 ACCESSORY KIT INSTALLATION INSTRUCTIONS PROPANE CONVERSION - INDUCED COMBUSTION FURNACES 1NP0347 FOR USE WITH 90% + MODELS: GF9S, GY9S, GM9S, PS9, FL9S, FC9S, PT9, FL9T, FC9T, GM9T, PV9, FL9V, FC9V, GM9V,

More information

Rheem Classic Series Heat Pump

Rheem Classic Series Heat Pump Heat Pumps Rheem Classic Series Heat Pump Efficiencies: 14 SEER/11.5 EER 8.2 HSPF Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Proper sizing and

More information

4SCU16LS PRODUCT SPECIFICATIONS 16 SEER SPLIT SYSTEM ENHANCED AIR CONDITIONING DESIGN COMPONENTS WARRANTY COMPRESSOR CABINET COILS

4SCU16LS PRODUCT SPECIFICATIONS 16 SEER SPLIT SYSTEM ENHANCED AIR CONDITIONING DESIGN COMPONENTS WARRANTY COMPRESSOR CABINET COILS PRODUCT SPECIFICATIONS 16 S SPLIT SYSTEM ENHANCED AIR CONDITIONING FORM NO. -100 (06/2014) DESIGN Designed for ambients up to 125 F COMPONENTS Service valves positioned for quick installation and easy

More information

Customer Responsibilities

Customer Responsibilities Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation

More information

208 Design Guide 2/4/2013

208 Design Guide 2/4/2013 208 Design Guide 2/4/2013 Eclipse ThermJet Self-Recuperative Burners Models TJSR0020 - TJSR0100 Version 5 Copyright Copyright 2010 by Eclipse, Inc. All rights reserved worldwide. This publication is protected

More information

Tube Puller CP/CPS series. Pullers designed with cutting edge technology

Tube Puller CP/CPS series. Pullers designed with cutting edge technology Q U A L I T Y T U B E T O O L S www.krais.com CP/CPS series Pullers designed with cutting edge technology Q U A L I T Y T U B E T O O L S w w w. k r a i s. c o m MAIN FEATURES All new CP collet type and

More information

Customer Responsibilities

Customer Responsibilities Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation

More information

6000SLX HYDRAULIC CRAWLER CRANE

6000SLX HYDRAULIC CRAWLER CRANE HYDRAULIC CRAWLER CRANE HYDRAULIC CRAWLER CRANE Contents Specifications 3-4 Symbols 4 Outline Winch Assingment 5 Dimensions & Main Specifications : Liftcrane 6 Dimensions & Main Specifications : Luffing

More information

Rheem Classic Series Two Stage Heat Pump

Rheem Classic Series Two Stage Heat Pump Heat Pumps Rheem Classic Series Two Stage Heat Pump Efficiencies: 15-16 SEER/11.5-13 EER Nominal Sizes 2, 3, 4 and 5 Ton [7.03, 10.6, 14.06 and 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7

More information

Work Horses of the Breathing Air Industry

Work Horses of the Breathing Air Industry High Pressure Breathing Air Equipment Work Horses of the Breathing Air Industry Pegasus Compressor The Pegasus vertically enclosed compressor is a full-featured system that incorporates the latest technology

More information

Type 1 - Nitrogen Generation System. Designed for: Dry or Pre-Action Fire Protection Systems (FPS) with a total capacity up to 750 gallons

Type 1 - Nitrogen Generation System. Designed for: Dry or Pre-Action Fire Protection Systems (FPS) with a total capacity up to 750 gallons Type 1 - Nitrogen Generation System Designed for: Dry or Pre-Action Fire Protection Systems (FPS) with a total capacity up to 750 gallons 1.0 Nitrogen Generation Corrosion Inhibiting System 1.1 The Fire

More information

Rheem Classic Series Heat Pump

Rheem Classic Series Heat Pump Heat Pumps Rheem Classic Series Heat Pump Efficiencies: up to 14 SEER/11.5 EER/8.2 HSPF Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Proper sizing

More information

/ /

/ / GN 4- kw/5.5-0 hp Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward GN: the dual output solution From cargo blanketing in LNG vessels to the inflation of Formula tires, nitrogen is used in

More information

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES PROCESS ANALYSERS DF-550E The DF-550E Nano Trace oxygen analyser is a Coulometric sensor based analyser designed to measure oxygen as a contaminant at ultra trace levels in ultra high purity electronic

More information

OPERATION AND MAINTENANCE INSTRUCTION MANUAL

OPERATION AND MAINTENANCE INSTRUCTION MANUAL OPERATION AND MAINTENANCE INSTRUCTION MANUAL AA-74 AIRPAC COMPRESSOR - 120 VOLT - TABLE OF CONTENTS: Introduction.........................1 Package Contents....................1 Operation...........................2

More information

installation instructions

installation instructions installation instructions GAS CONVERSION KIT PROPANE-TO-NATURAL P/N 315572-71201 4GAD 6GAD Cancels: IIK 4G-50-4 IIK 4G-50-5 7/15/91 NOTE: Read the entire instructions before starting the installation.

More information

PGM PREPIPED GAS MANIFOLD

PGM PREPIPED GAS MANIFOLD INSTRUCTIONS PGM PREPIPED GAS MANIFOLD WARNING These instructions are intended for use only by experienced, qualified combustion start-up personnel. Adjustment of this equipment and its components by unqualified

More information

Job Number Plant Location 123 Roadrunner Avenue, Tombstone, AR Fuel Devices

Job Number Plant Location 123 Roadrunner Avenue, Tombstone, AR Fuel Devices Combustion Services Safety Survey ETRO SERVICES Incorporated Customer Acme Incorporated Contact Name W. E. Coyote Job Number 5380 Plant Location 23 Roadrunner Avenue, Tombstone, AR 56884 Plant Name Test

More information

INSTALLATION GUIDE Gas Rangetops

INSTALLATION GUIDE Gas Rangetops INSTALLATION GUIDE Gas Rangetops Contents Wolf Gas Rangetops........................... 3 Safety Instructions............................ 4 Gas Rangetop Specifications.................... 5 Gas Rangetop

More information

GAS KITS & ACCESSORIES 504,986M 11/2004 HIGH ALTITUDE KIT

GAS KITS & ACCESSORIES 504,986M 11/2004 HIGH ALTITUDE KIT LENND 2004 Lennox Industries Inc. DaItas, Texas, USA GAS KITS & ACCESSORIES Litho U.S.A. 504,986M 11/2004 HIGH ALTITUDE KIT INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KIT (83M75) USED WITH G43UF & G51MP

More information

WARNING: Installation Instructions. Natural Gas High Altitude Conversion Kit United States Installations Only

WARNING: Installation Instructions. Natural Gas High Altitude Conversion Kit United States Installations Only Natural Gas High Altitude Conversion Kit United States Installations Only Installation Instructions Light Commercial Packaged Gas Electric Units R7TQ Series 6, - 7 1/2, & 10 Ton (2,001 FT - 10,000 FT)

More information

628 Differential Pressure Decay Leak Tester

628 Differential Pressure Decay Leak Tester 628 Differential Pressure Decay Leak Tester The 628 puts Uson s industry leading differential pressure decay sensitivity in your hands and in your budget with no compromise in quality, reliability, and

More information

UNDERSTANDING, ACCELERATED

UNDERSTANDING, ACCELERATED UNDERSTANDING, ACCELERATED MEASURE FLOW, PRESSURE, AND TEMPERATURE ALL IN ONE INSTRUMENT! Designed for Performance TSI thermal mass flowmeters incorporate a proprietary platinum film sensor design for

More information

Product Data. FA4A FB4A FC4B Direct Expansion Fan Coil. Sizes 018 thru 070. Air Handling Technology At Its Finest

Product Data. FA4A FB4A FC4B Direct Expansion Fan Coil. Sizes 018 thru 070. Air Handling Technology At Its Finest Product Data FA4A FB4A Direct Expansion Fan Coil Sizes 018 thru 070 Air Handling Technology At Its Finest Carrier s FA4A, FB4A, and direct expansion multipoise fan coils are designed to cover a wide range

More information

Liquid Level Controllers

Liquid Level Controllers Liquid Level Controllers ALL PUMPS LLC-2Y For both pump up and down control. Variable On/Off set points. NDP-15/20/25/32, DP-10/15 & *NDP-40/50/80 LLC-1 Pump up and down versions available. 6 to 12 differential

More information

2005 CERTIFICATE OF ACCEPTANCE (Part 1 of 3) MECH-1-A

2005 CERTIFICATE OF ACCEPTANCE (Part 1 of 3) MECH-1-A 2005 CERTIFICATE OF ACCEPTANCE (Part 1 of 3) MECH-1-A PROJECT ADDRESS TESTING AUTHORITY TELEPHONE Checked by/date Enforcement Agency Use GENERAL INFORMATION OF BLDG. PERMIT PERMIT # BLDG. CONDITIONED FLOOR

More information

Customer Responsibilities. Important Customer Information Series Q-TOF LC/MS Systems Site Preparation Checklist

Customer Responsibilities. Important Customer Information Series Q-TOF LC/MS Systems Site Preparation Checklist Thank you for purchasing an Agilent system. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation is

More information

Glycol Systems. Engineering Manual. 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers

Glycol Systems. Engineering Manual. 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers Glycol Systems Engineering Manual 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers Stulz Air Technology Systems, Inc. Table of Contents Section - 1 Table

More information

Customer Responsibilities. Important Customer Information. Agilent Infinity II Preparative HPLC System Site Preparation Checklist

Customer Responsibilities. Important Customer Information. Agilent Infinity II Preparative HPLC System Site Preparation Checklist Agilent Site Preparation Infinity II Checklist Preparative HPLC System Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer

More information

Air Operated Hydraulic Pumping Systems to 50,000 psi

Air Operated Hydraulic Pumping Systems to 50,000 psi High Pressure Equipment Air Operated Hydraulic Pumping Systems to 50,000 psi PS-10: 10,000 psi PS-20: 20,000 psi PS-30: 30,000 psi PS-40: 40,000 psi PS-50: 50,000 psi PS-90: 90,000 psi High Pressure air

More information

40' SPARKMAN & STEVENS - NORTHSTAR -.CENTER COCKPIT - MOTIVATED SELLER

40' SPARKMAN & STEVENS - NORTHSTAR -.CENTER COCKPIT - MOTIVATED SELLER www.bestboatusa.com +17866235554 Fort Lauderdale Florida USA EMAIL : sales@bestboatusa.com 40' SPARKMAN & STEVENS - NORTHSTAR -.CENTER COCKPIT - MOTIVATED SELLER Boat Name: Sparkman & Stevens Year: 1976

More information

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners M/MR Modulating Valves design certified For Atmospheric, Infrared, and Direct Fired urners TALE OF CONTENTS Description/Specifications... 1 Introduction... 2 Direct Fired Applications (Negative Pressure)...

More information

hydro-pac, inc. Low-Pressure Gas Compressors 1500 to 6000 PSI

hydro-pac, inc. Low-Pressure Gas Compressors 1500 to 6000 PSI hydro-pac, inc. LX-SERIES Low-Pressure Gas Compressors 1500 to 6000 PSI hydro-pac, inc. LX-SERIES Features Hydro-Pac LX-SERIES Gas Compressors feature: Oil-free non lubricated gas pistons and cylinders

More information