VSD03M DIRECTIONAL CONTROL VALVES
|
|
- Conrad Copeland
- 5 years ago
- Views:
Transcription
1 NFPA SIZE D03 TYPICAL PERFORMANCE SPECIFICATIONS Performance is measured on a four-way circuit (full circuit). Performance may e reduced from that shown if a three-way circuit (half circuit) is used, i.e. A or B port plugged. MAXIMUM FLOW RATE - (up to) 20 gpm 76 lpm MAXIMUM OPERATING PRESSURE P, A, B Ports* 5000 psi 345 ar T Port 3000 psi 207 ar DESCRIPTION As a valve spool shifts, the spool lands cross over the valve ody ports. This can produce instantaneous high flow rates. MAXIMUM AC Solenoids up to 400 cpm CYCLE RATE DC Solenoids up to 300 cpm MOUNTING SURFACE WEIGHT ANSI/B93.7M D03 ISO 440 Size 03 Single Actuator 3.2 ls..45 kg Doule Actuator 3.9 ls..77 kg SPOOL S AVAILABLE SEE CHART * 2000 psi (38 ar) maximum on valves with solenoid codes 37 and 68. All pressure drops shown on this page are ased on 00 SUS fluid viscosity, and 0.87 specific gravity. See the chart elow for other viscosities. Fluid CS Viscosities SUS Multiplier For any other specific gravity (G ) the pressure drop (?P) will e approximately?p =?P (G /G). 4
2 TYPICAL PRESSURE DROP PRESSURE DROP (psid) 80 S FLOW (gpm) FLOW PATH?P CURVES FLOW CURVE NUMBER SPOOL SPOOL SHIFTED SPOOL CENTERED TYPE P to to T P to B A to T P to A or B A or B to T P to T A A Code & 2 B B Code & 2 E N/A 9 N/A F 5 5 N/A 8 N/A F Code N/A 8 N/A F N/A N/A G N/A N/A H N/A N/A 5 J N/A N/A K N/A 9 N/A L N/A N/A 9 N N/A N/A Q N/A N/A 5 Suplate S (Full Circuit) 5
3 SPOOL DESCRIPTION SYMBOL SPOOL FUNCTION CENTER POSITION CROSSOVER A All ports locked All ports locked B All ports open All ports open E F P & A locked B to T P locked A & B to T All ports locked, or P & A locked B to T P locked A or B to T P locked P locked F A & B restricted A or B restricted to T to T G P to A or B P to A & B T & A or B T locked locked H J K L N Q P to A & T B locked P to B A & T locked P & B locked A to T P to T A & B locked P to A B & T locked P to B & T A locked All ports open All ports locked, or P to B, A & T locked All ports locked, or P & B locked, A to T All ports open, restricted All ports locked, or P to A, B & T locked All ports open 6
4 MAXIMUM FLOW ALL SOLENOIDS EXCEPT 39 AND 68 FUNCTION (lpm) (70 ar) gpm 000 psi (lpm) (38 ar) gpm 2000 psi (lpm) (207 ar) gpm 3000 psi (lpm) (276 ar) gpm 4000 psi (lpm) (345 ar) gpm 5000 psi N/A Not availale in this configuration. * 00% rated voltage required psi maximum and 00% voltage required. MAXIMUM FLOW SOLENOID S 39 AND 68 ONLY F F G L E - K J & N H & Q AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC (53) (45) (60) (45) (60) (49) (64) (46) (76) (68) (49) (38) (49) (57) (49) (57) (72) (72) (38) (45) (49) (49) (57) (53) (9) (23) (53) (42) (53) (34) (60) (45) (64) (49) (76) (68) (49) (38) (49) (57) (49) (57) (72) (72) (38) (45) (49) (49) (57) (45) (5) (23) (53) (38) (53) (9) (60) (45) (64) (34) (76) (64) (45) (30) (45) (45) (45) (38) (72) (72) (38) (45) (45) (42) (53) (45) () (5) * 2 * (53) (38) (53) () (60) (42) (60) (23) (76) (64) (42) (26) (5) N/A (5) (72) (72) (9) (38) (30) (30) (53) (45) () () N/A (53) (38) (49) () (60) (38) (60) (5) (76) (57) (42) (26) (72) (72) (5) (9) (5) (5) (53) (45) (7.6) () N/A FUNCTION (lpm) (34 ar) gpm 500 psi (lpm) (69 ar) gpm 000 psi (lpm) (03 ar) gpm 500 psi (lpm) (38 ar) gpm 2000 psi NOTE: Test voltage was 90% of rated voltage unless specified otherwise. Performance is measured on a four-way curcuit (full circuit). Performance may e reduced from that shown if a three-way circuit (half circuit) is used, i.e. A or B port plugged. F G L (30) (30) 8 8 (38) (45) 0 2 (38) (38) (38) (34) (9) (26) (26) 7 7 (38) (45) 0 2 (38) (38) (38) (34) (9) (26) (26) 7 7 (38) (38) 0 0 (38) (26) (38) (26) (9) (26) (26) 7 7 (5) (26) (5) (9) (9) (38) (38) 0 0 7
5 TYPICAL ELECTRICAL CHARACTERISTICS INRUSH HOLDING VOLTAGE & VOLTAGE CURRENT HOLDING CURRENT HOLDING FREQUENCY LIMITS (AMPS) CURRENT MIN. VOLT. POWER SOLENOID VOLTS - Hz. MIN. - MAX. MAX. (AMP) (AMP) (WATTS) 33L, 60L L, 6L L, 68L L, 70L 24 DC L, 75L 2 DC DIMENSIONS NFPA D03 SIZE (Formerly D0) WRENCH ACCESS TO MOUNTING BOLTS THRU TOP OF VALVE ASSY. TYP ALL ASSY'S P,A,B T WATTS A SOL ASSY B SOL ASSY 4.4(F) AC 2.3 DC FOR COIL REMOVAL CLEARANCE 2.5 AC SOLENOIDS 3. DC SOLENOIDS #0-24 UNC X.00" SOCKET HEAD CAP SCREW 4-5 LBS-FT TORQUE 3.00 (F) REF 8.0 AC SOLENOIDS 9.22 DC SOLENOIDS 2.5 AC SOLENOIDS 3. DC SOLENOIDS MANUAL ACTUATOR PIN BOTH ENDS.03 T.25 B A.6.22 P.594 8
6 DIN CONNECTIONS #0-24 UNC X.00" SOC. HD. CAP SCREW 4-5 LBS-FT TORQUE.60 AC SOLENOID.82 DC SOLENOID (F) TYP. 2.5 AC SOLENOID 3. DC SOLENOID.38 (F) TYP REF. 8.0 AC SOLENOID 9.22 DC SOLENOID 2.5 AC SOLENOID 3. DC SOLENOID LBS-FT TORQUE CORE 5 LBS-FT MAX.TORQUE.65 (F) TYP..38 (F) TYP..26 REF REF. 5.5 AC SOLENOID 6. DC SOLENOID 5.77 AC SOLENOID 6.37 DC SOLENOID 9
7 ORDERING INFORMATION ONE ONE IF REQ D IF REQ D ONE ONE VSD03M G A DESIGN LETTER ADD IF REQ D PILOT TYPICAL ORDERING : VSD03M-3A-G-33L-A 0 2 3* 5* 6 FUNCTION OPTION Single operator 2 position Spring offset Doule operator 2 position Detented (No spring) Doule operator 3 position Spring centered Single operator 2 position Spring centered Single operator 2 position Spring offset * Operator identification reversed on L spool: VSD03M-3L: A solenoid on A port end, B solenoid on B port end. VSD03M-5L: A solenoid on A port end. VSD03M-5L-R: B solenoid on B port end. a SPOOLS REFER TO PAGE 6 FOR SPOOL AVAILABILITY SEALS VITON SEALS STANDARD MECHANICAL OPTIONS OMIT R M V Z* WD DESCRIPTION SINGLE SOLENOID A PORT END SINGLE SOLENOID B PORT END RIVET MOUNTING STEEL OVERRIDE PIN MANUAL OVERRIDE FOR SINGLE SOLENOID VALVE WASHDOWN * Availale with single solenoid valves only. ELECTRICAL OPTIONS OMIT B B3A* B3H* B4A** B4** B5A* B5H* HD DESCRIPTION DIN STYLE SOLENOIDS BOX W/TERMINAL POSTS, LIGHTS AND SURGE SUPPRESSOR BOX W/3 PIN MALE MINI RECEPTACLE, A PORT END BOX W/3 PIN MALE MINI RECEPTACLE, B PORT END BOXW/4 PIN MALE MICRO RECEPTACLE, A PORT END BOXW/4 PIN MALE MICRO RECEPTACLE, B PORT END BOX W/5 PIN MALE MINI RECEPTACLE, A PORT END BOX W/5 PIN MALE MINI RECEPTACLE, B PORT END HAZARDOUS DUTY BOX CLASS II GROUPS E, F, & G L * Connector conforms to ANSI/B93.55M ** Availale with DC solenoid valves only. Availale with single solenoid valves only. SOLENOID MFG. DESCRIPTION LISK SOLENOID VOLTAGE WITH DIN ELECTRICAL CONNECTIONS 20/0V /220 V /240 V 35 20/0V 39 (LOW FORCE) VDC 44 2 VDC WITH 2 PIN CONNECTIONS 240/220V 52 HAZARDOUS LOCATION 60 20/0 V 240/220 V 6 20/0 V 68 (LOW AMP, LOW FORCE) VDC 75 2 VDC NOTE: Solenoids not CSA approved.
8 COMPETITIVE CROSSOVER GUIDE This Crossover Guide compares performance and specifications of solenoid operated NFPA D03 mounting directional control valves. The information in this guide is the most recent availale, either from printed catalogs, or the internet. Items with the N/A notation have no availale information from either source. Specifications Continental Atos Bosch Denison Nachi Parker Rexroth Vickers Model Series VSD03M DH* 08WV A4D0 SS DVW 4WE6 DG4V Maximum Pressure Maximum Tank Pressure Maximum Tank Pressure - Option N/A 3000 N/A 3000 Temperature Range (Degrees F.) 0 to to 58 0 to 20 0 to 20 4 to 40 N/A 0 to 22 0 to 49 Spools Availale Maximum Flow Rate (gpm) Pressure 0 gpm Solenoids Availale Electrical Connections Antishock / Softshift Option Option N/A Option Option Option Option Option Hazardous Duty Location Option Option N/A Option N/A Option N/A Option Explosion Proof Location Option Option N/A Option N/A Option N/A N/A Drip Proof Environment Option N/A Option N/A N/A Option N/A Option Weight - Single Solenoid 3.25 N/A Weight - Doule Solenoid 4.0 N/A VAC / 60Hz Inrush Amperage Holding Amperage Holding Wattage 2 N/A Solenoid Shift Time (ms) 2 20 to to to 20 8 Spring Return Time (ms) 5 20 to to to Theoretical Cycling (Hz) to to to 2 0 Actual Cycling (Hz) N/A 2 N/A 24 VDC Solenoid Shift Time (ms) to to to to Spring Return Time (ms) to 80 0 to to to Theoretical Cycling (Hz) to to to to 5 Actual Cycling (Hz) Other Criteria N/A 4.2 N/A Buna-N Option Option N/A Option Option Option Option Option Viton Standard Option Standard Option Option Option Standard Option Neoprene Option Option N/A Option N/A Option N/A N/A EPR Option Option N/A Option N/A Option N/A N/A CSA Approved Yes N/A Yes N/A Option Yes N/A N/A ETL or UL Listed Yes N/A Yes N/A N/A CE Approved Yes N/A Yes N/A N/A Indicator Lights Standard Option Option Option Standard Option Option Option 00% Testing Yes N/A N/A Yes N/A Low Watt Option Yes Option Yes N/A Option Surge Suppression Standard Option Option N/A N/A
MOUNTING SURFACE MOUNTING POSITION MAXIUMUM OPERATING PRESSURE FLUID OPERATING VISCOSITY FLUID CLEANLINESS HYSTERESIS REPEATABILITY THRESHOLD VOLTAGE
TYPICAL PERFORMANCE SPECIFICATIONS DESCRIPTION These proportional valves are direct operated pressure reducing valves. They can be used to control pressure in parts of a circuit. This valve incorporates
More informationBW0500AO. ByWire Elements BW0500AO Element 4/3 with side ports IBW0500 Interface
ywire Elements Element 4/3 with side ports IW5 Interface efore use, carefully read the GENERL INSTRUCTIONS FOR USE OF DIRECTIONL CONTROL VLVES 398SW5EN - 5--8 Technical data Nominal flow 5 l/min 3. US
More informationElectrically Operated Pressure-Relief Cartridge, Size 10
Electrically Operated Pressure-Relief Cartridge, Size 1 Q max = 14 l/min (37 gpm), p max = bar (5 psi) seated pilot stage, spool-type design, with remote contral port Z Series WUVPOC-2, WUVPLC-2 1 Description
More informationFlow Controls. DG**-06 Series Stacking Valves. Vickers. ISO (D06) Interface Flows to 340 l/min (90 USgpm) Pressure to 210 bar (3000 psi)
Vickers Flow Controls DG**-6 Series Stacking Valves ISO-441-8 (D6) Interface Flows to 34 l/min (9 USgpm) Pressure to 21 bar (3 psi) 5125./EN/598/A Introduction These stackable modules are designed for
More informationSandwich Valves. 1 Change in flow, temperature or fluid (SSU) rating will affect valve
Technical Information Series PRM General Description Series PRM reducing valves are used to regulate pressure, in one area of a circuit, below normal system pressure. This style valve is well suited to
More informationDirectional Valves. Hydraulic Operated Directional Valves
Service Data Vickers Directional Valves Hydraulic Operated Directional Valves (F*) DG3V 8 (B) ** (L) (X) (*) (*) 10 (EN**) Released 04/96 5007.03/EN/0496/S DG3V-8-*(C) - (X) - 10 Spring Centered 473726
More informationProportional Pressure-Relief Cartridge Valve, Size 2...4
Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description proportional pressure-relief valves are direct acting
More informationInverse Prop. Pressure-Relief Cart., Size 2 4
Inverse Prop. Pressure-Relief Cart., Size Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description inverse proportional pressure-relief valves are direct acting screw-in
More informationDirectional Controls
Vickers Directional Controls Directional Control Valves DG3V-3-*-60 Hydraulic Operated DG17V-3-*-60 Lever Operated DG18V-3-*-60 Air Operated DG20V-3-*-60 Cam Operated DG21V-3-*-60 Plunger Operated CETOP
More informationPILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R
PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R Veljan Pressure Reducer Valve Series VR4R are pilot operated controls used to control pressure in a secondary part of a hydraulic circuit. Pressure is
More informationPILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R
PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R Veljan Pressure Reducer Valve Series VR4R are pilot operated controls used to control pressure in a secondary part of a hydraulic circuit. Pressure is
More informationProp. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08
Prop. -Way Pressure-Reducing Cart., Size / SAE 8 Q max = 1 l/min (4 gpm), p max = bar (6 psi) Direct acting, electrically operated 1 Description proportional -way pressure-reducing cartridges are size
More informationPressure reducing valve, pilot operated, Model 3DR
RA 26 928/06.98 Pressure reducing valve, pilot operated, Model 3DR Nominal size 16 Series 5X Maximum operating pressure 3600 PSI (250 bar) Maximum flow 58.1 GPM (220 L/min) Contents Description Page Features
More informationIntrinsically safe solenoid valves on/off controls - ATEX certification
www.atos.com Table E130-17/E Intrinsically safe solenoid valves on/off controls - ATEX certification valve body valve spool intrinsically safe solenoid electrical connector manual override DHW-0611/WP/6
More informationProportional Pressure-Relief Cartridge Valve, Size 2...4
Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min, p max = 3 bar Direct acting, electrically operated 1 Description proportional pressure-relief valves are direct acting screw-in cartridges
More informationInverse Proportional Pressure-Relief Cart., Size 2 4
Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 35 bar Direct acting, electrically operated Description Compact construction for cavity type AL 3/-6 UNF Operated by a proportional
More informationInverse Proportional Pressure-Relief Cart., Size 2 4
Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 5 bar Direct acting, electrically operated 1 Description inverse proportional pressure-relief valves are direct acting screw-in cartridges
More informationDirectional Controls
Vickers Directional Controls Lever Operator Directional Control Valves DG17S-8-**-10 DG17S4-10 **-50 NF D08/D10, ISO-4401-08/10 Released 5/94 681 able of Contents General Information..................................................................................
More informationPVQ 13 A2 R SE 1 S 20 C-11 D
PVQ - Variable Displacement Piston Pump PVQ 13 A2 R SE 1 S 2 C-11 D 1 2 3 4 6 7 8 9 1 1 Model Series PVQ Inline Piston Pump Variable Volume Quiet Series 4 Rotation Viewed from shaft end R Right hand, standard
More informationFEPA PNEUMATICALLY AND SOLENOID ACTUATED VALVES, ONE UNIT MOUNTED TYPE VPG
PNEUMATICALLY AND SOLENOID ACTUATED VALVES, ONE UNIT MOUNTED TYPE VPG TECHNICAL CHARACTERISTICS Number of ways / positions : 3/2, 3/3, 5/2, 5/3, 5/4 Nominal sizes (ND) : 4, 6, 9, 12 Medium : compressed
More informationSDM to 8 sections monoblock valve D1WWDA02A
SDM 1 SDM1 1 to 8 sections monoblock valve D1WWDA2A SDM1 Additional information This folder shows the product in the most standard configurations. Please contact Sales Dpt. for more detailed information
More information005 Series Modular Valves
5 Series Modular Valves ype of Modular Valve Class Graphic Symbols age Solenoid Operated Directional Valve DSG-5- *** - * - ressure Control Valves Flow Control Valves Directional Control Valves Modular
More informationDual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11
Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11 Two normally closed safety shutoff valves in one housing; each with the following approvals. CSA Certified ANSI Z21.21 CSA 6.5 Marked C/I
More informationPILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R
PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R Veljan Pressure Reducer Valve Series VR4R are pilot operated controls used to control pressure a secondary part of a hydraulic circuit. Pressure is mataed
More informationInverse Proportional Pressure-Relief Cartridge, Size 10
Inverse Proportional Pressure-Relief Cartridge, Size 1 Q max = 12 l/min, p max = 3 bar Seated pilot, spool-type main stage, damped design 1 Description inverse-proportional pressure-relief valves are size
More informationDual Modular Safety Shutoff Valves. DMV-D/11 Series DMV-DLE/11 Series
Dual Modular Safety Shutoff Valves DMV-D/11 Series DMV-DLE/11 Series Two normally closed safety shutoff valves in one housing; each with the following approvals. CSA Certified ANSI Z21.21 CSA 6.5 Marked
More informationLoad Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm)
Vickers Cartridge Valves Load Controls Screw In Cartridge Valves Pressures to 50 bar (5000 psi) Flows to 90 l/min (50 USgpm) Rev. 2/99 722 Contents MODEL DESCRIPTION TYP. APPLICATION PRESSURE bar (psi)
More informationPressure reducing valve, pilot operated
Pressure reducing valve, pilot operated RE 26928/09.07 Replaces: 10.97 1/8 Type 3DR Size 16 Component series 5X Maximum operating pressure 250 bar Maximum flow 220 l/min H5844 Table of contents Content
More information3-Way Safety Block DSV
3-Way Safety Block DSV DSV 10 - M DSV 10 - M - T-ball DSV 10 - EY 1. Description 1.1. GENERAL The 3-way safety block is used to shut off and discharge hydraulic accumulators or consumers. It complies with
More informationVickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94
Vickers Flow Controls Flow Controls FN, F(C)G, FRG Released 6/94 685 Table of Contents FN03/06/10 Model Series Application Data...............................................................................
More informationMonoblock directional control valves ML - Directional control valve
Monoblock directional control valves ML - Directional control valve ML Before use, carefully read the GENERAL INSRUCIONS FOR USE OF DIRECIONAL CONROL VALVES 398SMD4I - 6--8 ML echnical data Nominal flow
More informationDNS. Monoblock directional control valves DNS - Directional control valve
Monoblock directional control valves DNS - Directional control valve DNS efore use, carefully read the GENERL INSRUCIONS FOR USE OF DIRECIONL CONROL VLVES 398SMD6I - 6--8 DNS echnical data Nominal flow
More informationMECHANICALLY OPERATED DIRECTIONAL VALVES Rotary Type : DRT/DRG-02 Cam Operated : DCT/DCG-01, 03 Threaded Connection/Sub-plate Mounting
MCHNICLLY ORD VLVS Rotary ype : DR/DRG- Cam Operated : DC/DCG-, hreaded Connection/ Mounting General Information Up to 5 Ma (6 SI), L/min (6. U.S.GM) ub. C-6 hese valves are chiefly used to shift the pilot
More informationDual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series
Dual Modular Safety Shutoff Valves DMV-D/602 Series DMV-DLE/602 Series Two normally closed safety shutoff valves in one housing; each with the following approvals. UL Recognized UL 429 File # MH16727 CSA
More informationSPCH/ Blowing block
> > for linear stretch blow moulding machines > > Compact and safe design > > Best suited for PET bottles up to litres, depending on cycle time Technical features Medium: Compressed air (purity class 3..3
More informationF05MSV-N* CONTINENTAL HYDRAULICS FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK F05MSV-N* - FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK
CONTINENTAL HYDRAULICS F05MSV-N* FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK F05MSV-N* - FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK 5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: 952.895.6400
More informationPRESSURE SEQUENCE VALVE TYPE UZK
PRESSURE SEQUENCE VALVE TYPE UZK Size 10, 20, 30 31,5 MPa up to 450 dm 3 /min WK 450 414 04. 2000r. Pressure sequence valves type UZK are used for switching a system or part of a system off when a set
More informationPRESSURE COMPENSATORS TECNORD
PRESSURE COMPENSATORS 2-way, Compensating / Reducing Valves GPM PSI LPM BAR MODEL CAVITY PAGE 8 3500 30 245 DF-CP2 7/8 14 UNF 60 16 3500 60 245 QC-CP2 Special 62 Typical Schematic Typical application for
More informationFull Range Pressure Compensating Variable Flow Control
Engineering & Manufacturing Solutions Specifications: See flow chart for capacity. Rated for 3000 psi (207 bar). Weighs 7- ¾ lbs. (3.52 kg). 30-Micron Filtration Recommended. Torque to turn side lever
More informationFunction. Valve Size. Pilot Oil. p min. Bold: Designates Tier I products and options.
Catalog HY14-255/US echnical Information ilot Operated ressure Reducing Valves Series VMY*6 General Series VMY*6 valves consist of the main stage with valve spools and the pilot stage with the proportional
More informationDual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11
Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11 Two normally closed safety shutoff valves in one housing; each with the following approvals. CSA Certified ANSI Z21.21 CSA 6.5 Marked C/I
More informationMV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:
MV-01 2/2-way Solenoid Valve for Fluids Description: Features / Nominal diameters 1/4-2 / Pressure up to 10 bar / 24 V DC and all common AC variants / Forced-lifting The pilot-controlled full-way valve
More informationFIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:
LOW PRESSURE FILTERS Max Flow: gpm ( lpm) In-Tank Filters Working Pressures to: Rated Static Burst to: psi kpa bar psi kpa bar Flow Range to: gpm lpm Features STYLE C STYLE D STYLE E in-tank filters are
More informationCover headline. Cover subheadline. Check Valves
Check Valves Cover headline Direct and pilot operated check valve functions for applications up to 5 bar (5 psi) and 7 L/min (6 USgpm) Cover subheadline EATON Screw-In Cartridge Valves E-VLSC-MC-E December
More informationSPC*01 (2-way) SPC03/06 (2-way) Size NG6 NG10 NG16 NG25 DIN A10 ISO 4401 NFPA D05 CETOP 5 P, A, B:
Catalog HY14-255/US Technical Information General Description sandwich type pressure s are typically used in combination with proportional directional control valves. The keeps the pressure drop over the
More informationProportional Throttle Cartridges, Size 16
Proportional Throttle Cartridges, Size 16 Q max = 5 l/min, p max = 5 bar, Q N max = 14 l/min at p 1 bar Two-Stage, with Seat-Valve Shut-Off 1 Description Normally closed Seat-valve shut-off from 1 Compact
More informationIndustrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US
Industrial Hydraulic Valves Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories Catalog HY14-2500/US Industrial Hydraulic Valves WARNING USR RSPONSIBILITY FAILUR OR IMPROPR
More informationDual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series
Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure DMV-D/624L Series DMV-DLE/624L Series Two normally closed automatic shutoff valves in one housing. Valve 2 (V2) incorporates proof
More informationSolenoid valves VZWF, force pilot operated
Key features and overview Function Normally closed solenoid valve with diaphragm and forced lifting. When the solenoid is energised, the differential pressure from the secondary side of the diaphragm is
More informationDual Modular Safety Shutoff Valve with NEMA 4x Enclosure. DMV-D/604L Series DMV-DLE/604L Series
Dual Modular Safety Shutoff Valve with NEMA 4x Enclosure DMV-D/604L Series DMV-DLE/604L Series Two normally closed automatic shutoff valves in one housing; each with the following approvals. UL Listed
More informationVALVES ISO 5599/1, SERIES IPV-ISV
VALVES ISO 99/1, SERIES IPV-ISV The assembly surface dimensions of ISO1 and ISO2 valves are to ISO99-1. They are available in the -way versions with 2 and 3 positions and with pneumatic or solenoid actuation.
More informationSOLENOID VALVES AND PNEUMATIC VALVES
9 S E R I E S Electropneumatically and pneumatically operated valves Series 9 Assembly with sub-base (ISO 5599/1 Standards) Sizes 1, 2 and 3 The Series 9 electropneumatically or pneumatically operated
More informationDual Modular Safety Shutoff Valves with Proof of Closure. DMV-D/622 Series DMV-DLE/622 Series
Dual Modular Safety Shutoff Valves with Proof of Closure DMV-D/622 Series DMV-DLE/622 Series Two normally closed automatic shutoff valves in one housing. Valve 2 (V2) incorporates proof of closure. Each
More informationDual Modular Safety shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634
Dual Modular Safety shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634 Two normally closed automatic shutoff valves in one housing.
More information4/2 way Pneumatic Solenoid Valve
4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11
More informationD62 - D63 Directional Control Valve l/min
D62 - D63 Table of Contents 1 1.1 1.2 Product Description... 2 Function... 2 Properties... 2 2 Technical Data... 3 3 3.1 3.2 Ordering Information... 4 Type code... 4 Versions currently available... 4 4
More informationPVK OPEN LOOP PUMPS. Bulletin E
PVK OPEN LOOP PUMPS Bulletin 47025-E Table of Contents Performance Assurance page 3 Features and Benefits page 4-5 Specifications page 6 Pump Controls page 7 Table of Contents Curves Performance page 8
More information1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type
Flow Control Valve Series LVM.. high flow rates (8 l/min) flow rates are unaffected by temperature change or when the higher load pressure alternates between the outlet ports proportional flow-sharing
More informationDual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series
Dual Modular Safety Shutoff Valves DMV-D/602 Series DMV-DLE/602 Series Two normally closed safety shutoff valves in one housing; each with the following approvals. UL Recognized UL 429 File # MH16727 CSA
More informationCheck Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.
Vickers heck Valves Operated heck Valves 4G-10, 20 Series, 20 Series 4T-06/10, 20 Series Typical Section 4T1-06-D*-20-U, illustrating external drain and decompression features asic haracteristics Maximum
More informationManapak Sandwich Valves Series CM, CPOM, FM, PRDM, PRM, RM
Catalog HY14-252/US Introduction Series C, CPO, F, PRD, PR, R anapak valves provide a variety of check, flow control, pressure relief and pressure reducing functions in a compact NFPA D3, D5 and D8 sandwich
More informationPressure reducing valve, direct operated
Electric Drives and Controls Table of contents Hydraulics Pressure reducing valve, direct operated Model ZDR 6 D Nominal size 6 Series 4X Maximum operating pressure 20 bar (3050 PSI) Maximum flow 50 L/min
More informationPressure reducing valve, direct operated
Electric Drives and Controls Table of contents Hydraulics Pressure reducing valve, direct operated Model DR 10 DP Nominal size 10 Series 4X Maximum reduced pressure 210 bar (3050 PSI) Maximum flow 80 L/min
More informationDual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series
Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure DMV-D/624L Series DMV-DLE/624L Series Two normally closed automatic shutoff valves in one housing. Valve 2 (V2) incorporates proof
More informationSafety Shutoff Valves MVD/6 Series MVDLE/6 Series
Safety Shutoff Valves /6 Series /6 Series Normally closed safety shutoff valve with the following approvals. UL Listed UL 49 File # MH16 CSA Certified ANSI Z1.1 CSA 6. Marked C/I File # LR 111 FM Approved
More informationDigital directional & flow control valves D-DF(R)G
Digital directional & flow control valves D-DF(R)G Functional Symbols Model Code D-DFG- D-DFG-~ D-DFRG-/ D-DFG--C--- Digital directional & flow control valve Size Spool type (neutral position) : ll ports
More informationDual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series
Dual Modular Safety Shutoff Valves with Two-stage operation DMV-ZRD/602 Series DMV-ZRDLE/602 Series Two normally closed automatic shutoff valves in one housing; each with the following approvals. UL Recognized
More informationCV08-20 Check Valve DIRECTIONAL VALVES. DESCRIPTION A screw-in, cartridge-style, hydraulic check valve for use as a blocking or load-holding device.
DIRECTIONAL VALVES CV08-20 Check Valve DESCRIPTION A screw-in, cartridge-style, hydraulic check valve for use as a blocking or load-holding device. OPERATION The CV08-20 allows flow passage from 1 to 2,
More information4/3 Directional valve elements L85L1...(EDC-LV) with manual lever operated control with flow sharing control (LUDV concept) L85L1...
4/3 Directional valve elements L8L1...(EDC-LV) with manual lever operated control with flow sharing control (LUDV concept) L8L1...(EDC-LV) RE 1831-17 Edition: 2.216 Replaces: 7.12 Size 6 Series Maximum
More informationMin. Metered Flow Capacity L/min. Max. Oper. Pressure Kgf/cm (0.04)* F- FC G N -11 H01. Max. Metered Flow Capacity L/min.
Flow Control These are pressure and temperature compensating type valves and maintain a constant flow rate independent of change in system pressure (load) and temperature (Viscosity of the fluid). They
More informationTANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR
SIT Group 836-837 TANDEM MULTIFUNCTIONAL GAS CONTROL MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR ALL ADJUSTMENTS ACCESSIBLE FROM ABOVE
More informationRE / Meter out pressure compensator Sandwich plate design Type SCA... /Series 2X. Description of function, Section 1/6. Replaces: 09.
Meter out pressure compensator Sandwich plate design Type SCA... /Series X Sizes 6, 5 up to 35 bar up to 35 L/min RE 9 47/.96 RE 9 47/.96 Replaces: 9.87 Sandwich plate design Load compensation in lines
More informationWK /2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32. Size 32 up to 42 MPa 700 dm 3 /min DESCRIPTION OF OPERATION
2/2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32 Size 32 up to 42 MPa 700 dm 3 /min WK 490 907 04.1999r. 2/2 way cartridge valve type URZS 32 can be used to build hydraulic systems
More informationPilot Operated Check Valves Catalog Quick Reference
Quick Reference Pilot to Open Model No. Description Flow* Pressure Page RPC NCS/3 Pilot Operated Check Valve, Pilot to Open.5 l/min [5. US gal/min] RPC NCS/3 35 l/min [9.3 US gal/min] CP5- SDC-3 3 l/min
More informationMODULES. Maximum Flow U.S.GPM. Max. Operating Pressure MPa (PSI) L/min. 005 Series 25 (3630) Modular Valves. 01 Series 31.
F MODULES YUKEN's Modular Valves are stack type valves, and require no piping. hey not only rationalise system build, but they also meet the technical requirements for a variety of hydraulic systems. Stacking
More informationSafety and Shut-off Block SAF/DSV
Safety and Shut-off Block SAF/DSV 1. DESCRIPTION 1.1. GENERAL The HYDAC safety and shut-off block is used to shut off and discharge hydraulic accumulators or consumers. It complies with the relevant safety
More informationEx-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification ATEX, IECEx, EAC
www.atos.com Table -2/E Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification TEX, IEEx, E valve body spool ex-proof solenoid ex-proof inductive
More information4/3 Directional valve elements L8_P5 with proportional (ED-IP) control and with or without LS connections L8_P5 (ED-IP)
4/3 Directional valve elements L8_5 with proportional (ED-I) control and with or without LS connections L8_5 (ED-I) RE 1831-7 Edition: 2.21 Replaces: 7.12 7.212 Size Series Maximum operating pressure 31
More informationDirectional spool valves type WE6 electrically. operated type WE6 series 32
Directional spool valve electrically operated type WE6 series NS 6 up to 1,5 Ma up to 80 dm /min WK 40 970 06.011 LICION Directional spool valves type WE6 electrically operated are intended for change
More information180 Series Rotary Shear Directional Control Valve
180 Series Rotary Shear Directional Control Valve Up to l 38 lpm, 10 US gpm l 700 bar, 10,000 psi Milwaukee, WI 53235, US el: +1 (414) 769-6400 sales-us@webtec.com St. Ives, Cambs. E27 3LZ, UK el: +44
More informationW60 Spool & Sleeve Valves for ISO Bases (5599/I)
W60 Spool & Sleeve Valves for ases (59/I) 5/ Valves Single Solenoid Pilot Spring Return,7,,6 W60760 W6076 W60760 W6076 W60760 W6076 W6070 W607 * ase and electrical connector not included. 5/ Valves Double
More informationHIGH PRESSURE FILTERS DFDK Series Inline Duplex Filters 4568 psi up to 90 gpm
DFDK Series Inline Duplex Filters 4568 psi up to 9 gpm Hydraulic Symbol DFDK QL L Ball Valve A DFDK QT T Ball Valve (sizes 33 or larger) A B B Features The DFDK Filters have a filter head of ductile iron
More information4 qwer 2/2 3/2 4/2. Intrinsically Safe. Air and Inert Gas Intrinsically Safe Valves Brass, or Stainless Steel Bodies 1/4" to 1" NPT SERIES.
qwer Air and Inert Gas Valves Brass, or Stainless Steel Bodies 1/" to 1" NPT Features Designed solely for installation in intrinsically safe areas, with properly approved and sized current and voltage-limiting
More informationSeries 4 Cv= Air-Pilot operated valves. 3-way/2-position, 5-way/2-position, 5-way/3-position
3 Cv =.73-2.00 Series 4 Cv=.73-2.00 Air-Pilot operated valves Series 4: 1/8,, 3-way/2-position; 5-way/2-position; 5-way/3-position 1/2 5-way/2-position The pneumatically operated,3-way/2-position, 5-way/2-position
More informationSPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection
SPOOL VALVES pilot operated single/dual solenoid (mono/bistable function) ISO 07-8 mm - pad mounting body M connection x/ - / - / Series 0 ISO 07- (8 mm) FEATURES M connection on top of valve: reduces
More informationSV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT. SV/614 Series SV-DLE/614 Series
SV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT SV/614 Series SV-DLE/614 Series Normally closed automatic shutoff valve with proof of closure and the following approvals. CSA Certified
More informationDual Modular Safety Shutoff Valves with NEMA 4x Enclosure DMV-D 704/604 DMV-DLE 704/604
Dual Modular Safety Shutoff Valves with NEMA 4x Enclosure DMV-D 704/604 DMV-DLE 704/604 Two normally closed safety shutoff valves in one housing; each with the following approval. CSA Certified ANSI Z21.21
More informationVICKERS. SystemStak Valves. ISO ; NFPA-D03; 315 bar (4500 psi); 60 L/min (15.7 USgpm) GB 2027B
VICKERS SystemStak Valves ISO 441-3; NF-D3; 315 bar (45 psi); 6 L/min (15.7 USgpm) 1 G 227 uild a Compact, Cost-Effective, Reliable Hydraulic System with Vickers SystemStak Valves Reduces System Space
More informationZ, Y, and X PURGE INDICATORS / CONTROLLERS
PurgEx XXXXXX Z, Y, and X PURGE INDICATORS / CONTROLLERS PURGE / PRESSURIZATION PURGE / PRESSURIZATION XXXXX XXXXXXXXX 8626 SERIES Globally Certified Z,Y,X Purge Indicators / Controllers and Accessories
More informationModel DE-1, VDE-1 and DE-2 Air Release Heads
SPECIFICATIONS Model DE-1, VDE-1 and DE-2 Air Release Heads Bulletin SS03030 Issue/Rev. 0.7 (8/17) Smith Meter Air Eliminator The Smith Meter Model DE Air Release Heads are dual-electric float switch devices
More informationDual Modular Safety Shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634
Dual Modular Safety Shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634 Two normally closed automatic shutoff valves in one housing.
More informationSafety and Shut-off Block SAF/DSV
1. DESCRIPTION 1.1. GENERAL The HYDAC safety and shut-off block is used to shut off and discharge hydraulic accumulators or user units. It complies with the relevant safety standards in accordance with
More informationCartridge Valves Technical Information. Pilot operated check valves. Quick reference
Quick reference Pilot to Open Model No. Description Flow* Pressure Page P RPC 4 NCS4/ Pilot Operated Check Valve, Pilot to Open l/min [ US gal/min] RPC 6 NCS6/ 5 l/min [7 US gal/min] CP45- SDC- l/min RPC
More informationINVERS. Solenoid coil 24VDC 12 VDC Exm Exd Explosion protection marking:
direct operated INVERSE function available Q max = 2 l/min p max = bar INVERS Description EPDB The direct operated proportional pressure relief valve is built as a slip-in cartridge fitted in a connecting
More informationMiniature controls. Contactors. Overload relays. Starters. Control relays
Contactors Overload relays Starters Control relays Description General features Wiring terminations available include plugon connectors, wire pins for PC board mounting and solder connections Low power
More informationSPECIFICATIONS ATTENTION
VPS 504 S06 Installation Manual - P/N 80122 - Ed. 01/09 VPS 504 S06 and S05 Valve Proving System Installation Instructions VPS 1 6 Gases Natural gas, air and other inert gases. NOT suitable for butane
More informationL125 SERIES POST-COMPENSATED SECTIONAL LOAD SENSE VALVE
L15 SERIES POST-COMPENSATED SECTIONAL LOAD SENSE VALVE TAKE CONTROL Take control with Muncie Power Products L15 directional control valve. The L15 is constructed with high-grade, iron castings and nickel-plated
More informationBERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features
Level Control Valve with Altitude Pilot High level reservoirs & water towers Energy cost critical systems Systems with poor water quality Inherent refreshing Level sustaining at reservoir outlet The Level
More informationSafety and Shut-off Block SAF/DSV
Safety and Shut-off Block SAF/DSV 1.1.1 Key to the circuit diagram Circuit diagram The HYDAC safety and shut-off block is used to shut off and discharge hydraulic accumulators or consumers. It complies
More informationThe Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure
General-purpose Limit Switch CSM_DA-_N_DS_E The Limit Switch with Better Seal, Shock Resistance, and Strength A double seal on the head, a complete gasket cover, and other features ensure a better seal
More information