S(U)200 series SU200M, SU200MR, and S200UDC UL 489 series

Size: px
Start display at page:

Download "S(U)200 series SU200M, SU200MR, and S200UDC UL 489 series"

Transcription

1 S(U)00 series SU00M, SU00MR, and S00UDC UL 489 series Description The SU00M, SU00MR, and S00UDC miniature circuit breakers offer a compact solution for protection requirements. The SU00 series devices are current-limiting according to UL 489 and DIN rail mounted. SU00M, SU00MR, and S00UDC MCBs come in up to 3 trip curves to provide maximum circuit protection. For the worldwide market, the breakers carry UL, CS, IEC, CE and many other agency approvals and certifications. Features UL current limiting Fast breaking time (.3.5 ms) Bus connection system Wide range of accessories vailable with variable depth handle mechanism CE certified and marked DIN rail mounting Finger safe terminals Multi-function terminals Suitable for reverse feed (except for S00UDC) UL 489 Listed - branch circuit protective device UL File #E33 SU00M SU00MR S00UDC mperage Voltage up to 77/Y480 VC 48/96 VDC up to 77/480 VC Trip curves Z, C, K K Z, K Interrupt rating 0 k- 0 k 4 k uxiliary contacts Yes Yes Yes Bell alarm Yes Yes Yes Shunt trip Yes Yes Yes Busbar Yes Yes Yes 60/5 VDC Miniature Circuit Breakers US Catalog

2 SU00M-C 0.5 SU0M-C SU03M-C0.5 SU0M-C SU03M-C.6 SU0M-C.6.6 SU03M-C.6 SU0M-C SU03M-C 3 SU0M-C3 3 SU03M-C3 4 SU0M-C4 4 SU03M-C4 5 SU0M-C5 5 SU03M-C5 6 SU0M-C6 6 SU03M-C6 8 SU0M-C8 8 SU03M-C8 0 SU0M-C0 0 SU03M-C0 3 SU0M-C3 3 SU03M-C3 3 5 SU0M-C5 5 SU03M-C5 6 SU0M-C6 6 SU03M-C6 0 SU0M-C0 0 SU03M-C0 5 SU0M-C5 5 SU03M-C5 30 SU0M-C30 30 SU03M-C30 3 SU0M-C3 3 SU03M-C3 35 SU0M-C35 35 SU03M-C35 40 SU0M-C40 40 SU03M-C40 50 SU0M-C50 50 SU03M-C50 60 SU0M-C60 60 SU03M-C60 63 SU0M-C63 63 SU03M-C SU0M-C SU04M-C0.5 SU0M-C SU04M-C.6 SU0M-C.6.6 SU04M-C.6 SU0M-C SU04M-C 3 SU0M-C3 3 SU04M-C3 4 SU0M-C4 4 SU04M-C4 5 SU0M-C5 5 SU04M-C5 6 SU0M-C6 6 SU04M-C6 8 SU0M-C8 8 SU04M-C8 0 SU0M-C0 0 SU04M-C0 3 SU0M-C3 3 SU04M-C3 4 5 SU0M-C5 5 SU04M-C5 6 SU0M-C6 6 SU04M-C6 0 SU0M-C0 0 SU04M-C0 5 SU0M-C5 5 SU04M-C5 30 SU0M-C30 30 SU04M-C30 3 SU0M-C3 3 SU04M-C3 35 SU0M-C35 35 SU04M-C35 40 SU0M-C40 40 SU04M-C40 50 SU0M-C50 50 SU04M-C50 60 SU0M-C60 60 SU04M-C60 63 SU0M-C63 63 SU04M-C63 US Catalog Miniature Circuit Breakers 3

3 SU00M-K 0. SU0M-K0. 0. SU03M-K SU0M-K SU03M-K SU0M-K SU03M-K SU0M-K SU03M-K0.75 SU0M-K SU03M-K.6 SU0M-K.6.6 SU03M-K.6 SU0M-K SU03M-K 3 SU0M-K3 3 SU03M-K3 4 SU0M-K4 4 SU03M-K4 5 SU0M-K5 5 SU03M-K5 6 SU0M-K6 6 SU03M-K6 8 SU0M-K8 8 SU03M-K8 0 SU0M-K0 3 0 SU03M-K0 3 SU0M-K3 3 SU03M-K3 5 SU0M-K5 5 SU03M-K5 6 SU0M-K6 6 SU03M-K6 0 SU0M-K0 0 SU03M-K0 5 SU0M-K5 5 SU03M-K5 30 SU0M-K30 30 SU03M-K30 3 SU0M-K3 3 SU03M-K3 35 SU0M-K35 35 SU03M-K35 40 SU0M-K40 40 SU03M-K40 50 SU0M-K50 50 SU03M-K50 60 SU0M-K60 60 SU03M-K60 63 SU0M-K63 63 SU03M-K63 0. SU0M-K0. 0. SU04M-K SU0M-K SU04M-K SU0M-K SU04M-K SU0M-K SU04M-K0.75 SU0M-K SU04M-K.6 SU0M-K.6.6 SU04M-K.6 SU0M-K SU04M-K 3 SU0M-K3 3 SU04M-K3 4 SU0M-K4 4 SU04M-K4 5 SU0M-K5 5 SU04M-K5 6 SU0M-K6 6 SU04M-K6 8 SU0M-K8 8 SU04M-K8 0 SU0M-K0 4 0 SU04M-K0 3 SU0M-K3 3 SU04M-K3 5 SU0M-K5 5 SU04M-K5 6 SU0M-K6 6 SU04M-K6 0 SU0M-K0 0 SU04M-K0 5 SU0M-K5 5 SU04M-K5 30 SU0M-K30 30 SU04M-K30 3 SU0M-K3 3 SU04M-K3 35 SU0M-K35 35 SU04M-K35 40 SU0M-K40 40 SU04M-K40 50 SU0M-K50 50 SU04M-K50 60 SU0M-K60 60 SU04M-K60 63 SU0M-K63 63 SU04M-K63 4 Miniature Circuit Breakers US Catalog

4 SU00M-Z 0.5 SU0M-Z SU03M-Z0.5 SU0M-Z SU03M-Z.6 SU0M-Z.6.6 SU03M-Z.6 SU0M-Z SU03M-Z 3 SU0M-Z3 3 SU03M-Z3 4 SU0M-Z4 4 SU03M-Z4 5 SU0M-Z5 5 SU03M-Z5 6 SU0M-Z6 6 SU03M-Z6 8 SU0M-Z8 8 SU03M-Z8 0 SU0M-Z0 0 SU03M-Z0 3 SU0M-Z3 3 SU03M-Z3 3 5 SU0M-Z5 5 SU03M-Z5 6 SU0M-Z6 6 SU03M-Z6 0 SU0M-Z0 0 SU03M-Z0 5 SU0M-Z5 5 SU03M-Z5 30 SU0M-Z30 30 SU03M-Z30 3 SU0M-Z3 3 SU03M-Z3 35 SU0M-Z35 35 SU03M-Z35 40 SU0M-Z40 40 SU03M-Z40 50 SU0M-Z50 50 SU03M-Z50 60 SU0M-Z60 60 SU03M-Z60 63 SU0M-Z63 63 SU03M-Z SU0M-Z SU04M-Z0.5 SU0M-Z SU04M-Z.6 SU0M-Z.6.6 SU04M-Z.6 SU0M-Z SU04M-Z 3 SU0M-Z3 3 SU04M-Z3 4 SU0M-Z4 4 SU04M-Z4 5 SU0M-Z5 5 SU04M-Z5 6 SU0M-Z6 6 SU04M-Z6 8 SU0M-Z8 8 SU04M-Z8 0 SU0M-Z0 0 SU04M-Z0 3 SU0M-Z3 3 SU04M-Z3 4 5 SU0M-Z5 5 SU04M-Z5 6 SU0M-Z6 6 SU04M-Z6 0 SU0M-Z0 0 SU04M-Z0 5 SU0M-Z5 5 SU04M-Z5 30 SU0M-Z30 30 SU04M-Z30 3 SU0M-Z3 3 SU04M-Z3 35 SU0M-Z35 35 SU04M-Z35 40 SU0M-Z40 40 SU04M-Z40 50 SU0M-Z50 50 SU04M-Z50 60 SU0M-Z60 60 SU04M-Z60 63 SU0M-Z63 63 SU04M-Z63 US Catalog Miniature Circuit Breakers 5

5 S00UDC-K S0UDC-K.6 S0UDC-K.6 S0UDC-K 3 S0UDC-K3 4 S0UDC-K4 5 S0UDC-K5 6 S0UDC-K6 8 S0UDC-K8 0 S0UDC-K0 3 S0UDC-K3 5 S0UDC-K5 6 S0UDC-K6 0 S0UDC-K0 5 S0UDC-K5 30 S0UDC-K30 3 S0UDC-K3 40 S0UDC-K40 50 S0UDC-K50 60 S0UDC-K60 63 S0UDC-K63 S0UDC-K.6 S0UDC-K.6 S0UDC-K 3 S0UDC-K3 4 S0UDC-K4 5 S0UDC-K5 6 S0UDC-K6 8 S0UDC-K8 0 S0UDC-K0 3 S0UDC-K3 5 S0UDC-K5 6 S0UDC-K6 0 S0UDC-K0 5 S0UDC-K5 30 S0UDC-K30 3 S0UDC-K3 40 S0UDC-K40 50 S0UDC-K50 60 S0UDC-K60 63 S0UDC-K63 Note: Standard UL 489 (only DC; please note polarity of device). US Catalog Miniature Circuit Breakers 7

6 S00UDC-Z S0UDC-Z.6 S0UDC-Z.6 S0UDC-Z 3 S0UDC-Z3 4 S0UDC-Z4 5 S0UDC-Z5 6 S0UDC-Z6 8 S0UDC-Z8 0 S0UDC-Z0 3 S0UDC-Z3 5 S0UDC-Z5 6 S0UDC-Z6 0 S0UDC-Z0 5 S0UDC-Z5 30 S0UDC-Z30 3 S0UDC-Z3 40 S0UDC-Z40 50 S0UDC-Z50 60 S0UDC-Z60 63 S0UDC-Z63 S0UDC-Z.6 S0UDC-Z.6 S0UDC-Z 3 S0UDC-Z3 4 S0UDC-Z4 5 S0UDC-Z5 6 S0UDC-Z6 8 S0UDC-Z8 0 S0UDC-Z0 3 S0UDC-Z3 5 S0UDC-Z5 6 S0UDC-Z6 0 S0UDC-Z0 5 S0UDC-Z5 30 S0UDC-Z30 3 S0UDC-Z3 40 S0UDC-Z40 50 S0UDC-Z50 60 S0UDC-Z60 63 S0UDC-Z63 Note: Standard UL 489 (only DC; please note polarity of device). 8 Miniature Circuit Breakers US Catalog

CMC Series Moulded Case Circuit Breaker Cielo Electric

CMC Series Moulded Case Circuit Breaker Cielo Electric Model name CMC: Series 225: mpere frame size Line side terminal In: Rated current Ue: Rated operational voltage Icu: Rated ultimate short-circuit breaking capacity Ta: mbient temperature In: 225 Icu: 55k@415V

More information

Miniature controls. Contactors. Overload relays. Starters. Control relays

Miniature controls. Contactors. Overload relays. Starters. Control relays Contactors Overload relays Starters Control relays Description General features Wiring terminations available include plugon connectors, wire pins for PC board mounting and solder connections Low power

More information

Circuit breakers PR 60

Circuit breakers PR 60 Circuit breakers PR series are mechanical switching devices able to switch, conduct and switch-off the current under normal conditions and able to switch, conduct and automatically switch-off the current

More information

Zelio Relays RSL Slim Interface Plug-In Relays

Zelio Relays RSL Slim Interface Plug-In Relays Zelio Relays RSL Slim Interface Plug-In Relays Catalog 8501CT0901 2009 Class 8501 CONTENTS Description............................................. Page Introduction.................................................3

More information

Meta-MEC Manual Motor Starters

Meta-MEC Manual Motor Starters www.lsis.biz Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 45 mm 70 mm 63AF 100AF 3 LS Meta-MEC Manual Motor Starters deliver more

More information

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm Dimensions 65 GW2 40 35 9 5 GW1 14 11 9 5.4 M20 x 1.5 0102 Model Number S M12 x 1.5 Features 77.5 LED V Direct mounting on standard actuators Compact and stable housing with terminal compartment connection

More information

References 6 k thermal overload relays, adjustable from 0.11 to 16 A

References 6 k thermal overload relays, adjustable from 0.11 to 16 A s 6 k thermal overload relays, adjustable from 0.11 to 16 A 3-pole relays with screw clamp terminals These overload relays are designed for the protection of motors. They are compensated and phase failure

More information

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up to SIL2 acc. to IEC 61508 Accessories

More information

VSD03M DIRECTIONAL CONTROL VALVES

VSD03M DIRECTIONAL CONTROL VALVES NFPA SIZE D03 TYPICAL PERFORMANCE SPECIFICATIONS Performance is measured on a four-way circuit (full circuit). Performance may e reduced from that shown if a three-way circuit (half circuit) is used, i.e.

More information

e2c 20 - easy to connect

e2c 20 - easy to connect closer contacts Fieldbus Communications e2c 20 - easy to connect e2c 20 / IP 20 Distributed I/O System for Switch Cabinets Switch cabinets and distribution boxes continue to rely on wiring systems that

More information

Technical Data. Dimensions

Technical Data. Dimensions 00 Model Number Features mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,

More information

OTL Universal terminals

OTL Universal terminals OTL Universal terminals 2019 Universal terminals OTL Universal terminals OTL 1000 V AC/DC Bimetal (AL/CU) Class A Certified according to standards EN 612381 and EN 6094771 2 Universal terminals OTL Universal

More information

CONTENTS TABLE OF MAIDA S HISTORY TERMINOLOGY & GENERAL SPECIFICATIONS. iii. LEAD CODES and TAPE & REEL STANDARD SERIES 1 HC SERIES 17

CONTENTS TABLE OF MAIDA S HISTORY TERMINOLOGY & GENERAL SPECIFICATIONS. iii. LEAD CODES and TAPE & REEL STANDARD SERIES 1 HC SERIES 17 TABLE OF CONTENTS MAIDA S HISTORY TERMINOLOGY & GENERAL LEAD CODES and TAPE & REEL i ii iii STANDARD SERIES 1 HC SERIES 17 LOW PROFILE SERIES 33 THERMALLY PROTECTED SERIES 39 HIGH ENERGY SERIES LEAD CODES

More information

CATALOGUE EXTRACT SIRCO PV. Disconnect switches for photovoltaic applications From 100 to 2000 A, up to 1500 VDC UL 98B & IEC

CATALOGUE EXTRACT SIRCO PV. Disconnect switches for photovoltaic applications From 100 to 2000 A, up to 1500 VDC UL 98B & IEC 2013 2014 CATALOGUE EXTRACT SIRCO PV Disconnect switches for photovoltaic applications From 100 to 2000 A, up to 1500 VDC UL 98B & IEC 60947-3 Load break switches sirco-pv_058_a_1_cat SIRCO PV UL98B sirco-pv_059_a_1_cat

More information

Dimensions [All numbers in brackets are in millimeters.] K4-2 US (supplied) 1/2" Centered (Default)

Dimensions [All numbers in brackets are in millimeters.] K4-2 US (supplied) 1/2 Centered (Default) Proportional damper actuator, non-spring return, Multi-Function Technology Torque min. Control to 0 VDC (DEFULT) Feedback to 0 VDC (DEFULT) For proportional modulation of dampers in HVC systems. The is

More information

Class CC/CD CCMR Series FUSES

Class CC/CD CCMR Series FUSES 0 VAC Dual Element Time-Delay / - A Description The CCMR series is ideal for space saving protection of motors up to hp*. It was designed specifically to withstand sustained starting currents of small

More information

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.

More information

CLASS CC/CD CCMR SERIES FUSES

CLASS CC/CD CCMR SERIES FUSES 0 Vac Dual Element Time-Delay / - A Description The CCMR series is ideal for space saving protection of motors up to hp*. It was designed specifically to withstand sustained starting currents of small

More information

Relative pressure transmitter type 520

Relative pressure transmitter type 520 Relative pressure transmitter type 520 Pressure range -1... 9 bar / 0... 2.5 1000 bar The compact type 520 pressure transmitter is based upon the Huba Control developed thick film technology where the

More information

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm 0102 Model Number Features 1.5 mm flush Accessories BF 8 Mounting flange, 8 mm Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 1.5 mm Installation flush

More information

ATH 500 M. Pumping speed ATH 500 M. 3.1 Vacuum generation / Turbopumps / Magnetically levitated / ATH 500 M. Page 398 / Part 3.1

ATH 500 M. Pumping speed ATH 500 M. 3.1 Vacuum generation / Turbopumps / Magnetically levitated / ATH 500 M. Page 398 / Part 3.1 ATH 500 M Compact integrated drive Installation in any orientation Water or air cooled CE marked and ROHS compliant Heated version (MT) available for corrosive applicaitons. Pumping speed N 2 He H 2 Ar

More information

KAL36150 Molded Case Circuit Breaker, 600VAC, 150A

KAL36150 Molded Case Circuit Breaker, 600VAC, 150A Product ata Sheet KL3 Molded ase ircuit reaker, 00V, List $1,733.00 US vailability Stock Item: This item is normally stocked in our distribution facility. Technical haracteristics pprovals UL Listed -

More information

Installation and Operation Manual

Installation and Operation Manual Manual Static pressure transducer with controller Differential static pressure transducer with analog output and optional PI control mode Large diaphragm element with differential transformer Transducer

More information

GENERAL APPLICATION NOTES

GENERAL APPLICATION NOTES GENERAL APPLICATION NOTES There are common considerations when using our connectors. Additional considerations may apply based on the particular connector being used, the application, and conditions in

More information

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure Siemens AG 204 Overview The pressure transmitter SITRANS P220 measures the gauge pressure of liquids, gases and vapors. Stainless steel measuring cell, fully welded Measuring ranges 2.5 to 600 bar (36.3

More information

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm Dimensions 7 36 5 33.5 9 5.4 30 65 0102 Model Number Features Direct mounting on standard actuators Fixed setting Satisfies machinery directive Compact and stable housing EC-Type Examination Certificate

More information

ACCESSORIES. Standard packing

ACCESSORIES. Standard packing ACCESSORIES HC RELAYS (Sockets and Terminal ) FEATURES. HC Relay Sockets In the table below, the suitable for each type of HC relay is indicated by a black dot. ) Plug-in type, type, and wrapping type

More information

Limit switches OsiSense XC Special For material handling applications, type XC1 AC

Limit switches OsiSense XC Special For material handling applications, type XC1 AC Presentation For material handling applications, type XC C b XC C with slow break contacts v With head for linear movement () 00_ 00_ 000_ Page / 00_ 00_ XCC XCC Page / XCC XCC / General characteristics

More information

Position switches FP series

Position switches FP series A Position switches FP series Selection diagram 0 08 8 9 0 0 0 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fiber glass rod gasket sphere sphere adjustable lever safety adjustable lever

More information

Socket P2RF-05-S P2RF-08-S Clip & Release Lever Nameplate R99-11

Socket P2RF-05-S P2RF-08-S Clip & Release Lever Nameplate R99-11 Screwless Clamp Terminal Socket P2RF@@S Screwless clamping greatly contributes to reducing wiring time. No over or under tightening of cable connection so better contact reliability is achieved. Double

More information

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm Dimensions M30x1,5 5 40 37 0102 Model Number 36 LED Features Comfort series 10 mm embeddable Connection BN BU Accessories BF 30 Mounting flange, 30 mm L+ L- Technical Data specifications Switching element

More information

Technical Data. Dimensions

Technical Data. Dimensions 00 Model Number Features Comfort series 30 mm non-flush Accessories MHW 0 Modular mounting bracket V-G Female connector, M, 4-pin, field attachable V-W-N-M-PUR Female cordset, M, -pin, NAMUR, PUR cable

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable

More information

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm Dimensions 65 9 5 14 40 35 11 9 5.4 M20 x 1.5 0102 S Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting Satisfies

More information

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition Siemens AG 07 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure

More information

C&G Level 3 Award in the Periodic Inspection, Testing and Certification of Electrical Installations

C&G Level 3 Award in the Periodic Inspection, Testing and Certification of Electrical Installations C&G 2395-01 Level 3 Award in the Periodic Inspection, Testing and Certification of Electrical Installations Test instruments and recommended testing sequence 1 Outcomes of this Session describe the different

More information

Compact pressure switches for gas and air

Compact pressure switches for gas and air Compact pressure es for gas and air / 5.0 Printed in Germany Edition 0.8 Nr. 9 544 6 Technical description The pressure is an adjustable compact pressure according to EN 854 for combustion plants. The

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 15 mm non-flush Stainless steel housing Accessories BF 30 Mounting flange, 30 mm Technical Data specifications Switching element function NAMUR, NC Rated operating

More information

EU Declaration of Conformity

EU Declaration of Conformity Product: Name and address of the manufacturer: Rockwell Automation Inc. 1201 South 2nd Street Milwaukee, WI 53204 U.S.A. EU Declaration of Conformity Global Moulded Case Circuit Breaker Accessories Name

More information

High-performance submersible pressure transmitter For level measurement Model LH-10

High-performance submersible pressure transmitter For level measurement Model LH-10 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well

More information

Meta-MEC Manual Motor Starters

Meta-MEC Manual Motor Starters Leader in Electrics & Automation Meta-MEC Manual Motor Starters Electric Equipment LG Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 45 mm 70 mm 63AF 100AF 3 LG Meta-MEC

More information

Digital Flow Switch. Series PFM7

Digital Flow Switch. Series PFM7 Compatible with rgon (r), Carbon Dioxide (CO) and the Mixed Gas (r+co) Digital Flow witch eries PFM7 Flow adjustment valve Fluid r, CO r + CO RoH -color display ee abnormal values at a glance. llows flow

More information

Pushbuttons and Indicating Lights

Pushbuttons and Indicating Lights Pushbuttons and Indicating Lights Pushbuttons Indicating Lights Emergency Stops Selector Switches.5 Product Overview.............................................. 2 Product Selection Guide.........................................

More information

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm Dimensions 65 9 5 40 35 14 11 9 5.4 M20 x 1.5 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting Satisfies machinery

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 10 mm flush Shielded PUR cable for oil and gas sector Accessories BF 30 Mounting flange, 30 mm Technical Data specifications Switching function Normally closed (NC) Output type

More information

High-performance submersible pressure transmitter For level measurement Model LH-10

High-performance submersible pressure transmitter For level measurement Model LH-10 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well

More information

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up

More information

EU Declaration of Conformity

EU Declaration of Conformity Product: Name and address of the manufacturer: Rockwell Automation Inc. 1201 South 2nd Street Milwaukee, WI 53204 U.S.A. EU Declaration of Conformity Global Moulded Case Circuit Breaker Accessories Name

More information

Oxymax H COS21. Technical Information. Sensor with long-term stability for frequent sterilization and autoclaving

Oxymax H COS21. Technical Information. Sensor with long-term stability for frequent sterilization and autoclaving Technical Information Oxymax H COS21 Sensor with long-term stability for frequent sterilization and autoclaving Application Process control in enzyme production Control of culture growth Biotechnological

More information

Gas Pressure Switch for DMV safety shutoff valves

Gas Pressure Switch for DMV safety shutoff valves Gas Switch for DMV safety shutoff valves GAO-A GMH-A GML-A UL Listed UL 353 File # MH 1668 CSA Certified CSA C. No. LR 53 File # 0157 FM Approved Class 3510, 3530 File # J.I. 1Y9A9.AF Commonwealth of Massachusetts

More information

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI Siemens AG 06 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure

More information

X2 Metallized Polypropylene Film Capacitor JFV

X2 Metallized Polypropylene Film Capacitor JFV FEATURES: Non-inductive, (UL940V-0) plastic case sealed with epoxy resin. Provides interference suppression with VDE, ENEC and UL approvals. SPECIFICATIONS: Operating Temperature -40 ~ +110 Maximum Continuous

More information

Pressure switch for gas and air

Pressure switch for gas and air Pressure switch for gas and air GAO-A4 GMH-A4 GML-A4 UL Listed UL 353 File # MH 16628 CSA Certified CSA C22.2 No. LR 53222 Certification # 201527 FM Approved Class 3510, 3530 File # J.I. 1Y919.AF GXX_A4

More information

15KPA-HRA Series. TVS Diodes Axial Leaded 15 kw > 15KPA-HRA series. Descritions

15KPA-HRA Series. TVS Diodes Axial Leaded 15 kw > 15KPA-HRA series. Descritions 5KPA-HRA Series RoHS Pb e3 Descritions Uni-directional The 5KPA-HRA High Reliability Series is designed specifically to protect sensitive electronic equipment from voltage transients induced by lightning

More information

Time Current Curves Series NRX NF and RF Circuit Breakers PXR 20/25 Trip Units

Time Current Curves Series NRX NF and RF Circuit Breakers PXR 20/25 Trip Units Series NRX NF and RF Circuit Breakers PXR 20/25 Trip Units Contents Description Page Revision notes....2 PXR catalog number convention....3 PXR 20 trip units....4 PXR 25 trip units....5 Curves Long Delay

More information

Gas Pressure Switch for DMV safety shutoff valves

Gas Pressure Switch for DMV safety shutoff valves Gas Switch for DMV safety shutoff valves GAO-A GMH-A GML-A UL Listed UL 353 File # MH 1668 CSA Certified CSA C. No. LR 53 File # 0157 FM Approved Class 3510, 3530 File # J.I. 1Y9A9.AF Commonwealth of Massachusetts

More information

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

Type N-10, N-11 Hazardous Area Non-incendive Transmitters Electronic Pressure Catalog > Hazardous Area > N-10, N-11 Type N-10, N-11 Hazardous Area Non-incendive Transmitters Applications Natural gas compressors Wellhead monitoring Pipeline pressure General industrial

More information

EPIC Rectangular Connector Inserts. HBE Series. Technical Data Number of Contacts:

EPIC Rectangular Connector Inserts. HBE Series. Technical Data Number of Contacts: HBE Series HBE series inserts provide reliable termination and performance in the vast majority of medium power and control applications. Methods of termination include screw, crimp, and spring cage clamp.

More information

EU Declaration of Conformity

EU Declaration of Conformity Product: Name and address of the manufacturer: Rockwell Automation Inc. 101 South nd Street Milwaukee, WI 0 U.S.A. EU Declaration of onformity IE ircuit Breakers and Accessories Name and address of the

More information

TERMINAL BLOCK SUMMARY

TERMINAL BLOCK SUMMARY TERMINAL BLOCK SUMMARY TERMINAL BLOCK SUMMARY TERMINAL BLOCK SUMMARY FEEDTHROUGH TERMINALS FUSE TERMINALS DISCONNECT TERMINALS MICRO TERMINALS CIRCUIT BREAKERS PRODUCT INFORMATION Feedthrough Terminals

More information

Pressure Switch for gas and air GGAO-A4

Pressure Switch for gas and air GGAO-A4 Pressure Switch for gas and air GGAO-A4 CSA Certified CSA C22.2 No. LR 53222 Certification file # 201527 Commonwealth of Massachusetts Approved Product Approval code G3-0106-191 Gas pressure switch Codes

More information

Prewired position switches FA series

Prewired position switches FA series 2 Prewired position switches FA series Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 51 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable lever 41 45

More information

The accuracy and safety of the connected measuring devices are directly regulated. of the introduced current transformers.

The accuracy and safety of the connected measuring devices are directly regulated. of the introduced current transformers. Product family Current transformers Current transformers (CTs) are introduced where it is difficult to access a direct measuring ot network current. Current transformer transforms the high network current

More information

Mass Flow Meter (MFM) for gases

Mass Flow Meter (MFM) for gases Mass Flow Meter (MFM) for gases Type can be combined with Inline MFM for nominal flow rates from 25 l N /min to 1,500 l N /min; 1/4 to 3/4 High accuracy Fast settling time Fieldbus option Special version

More information

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm 0102 Model Number Features 2 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-12 Quick mounting bracket with dead stop BF 12 Mounting flange, 12 mm Technical Data specifications Switching

More information

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications. Rated operating distance s n 5 mm 0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching

More information

Pressure Switch for gas and air

Pressure Switch for gas and air Switch for gas and air GAO-A4 GMH-A4 GML-A4 UL Listed UL 353 File # MH 16628 CSA Certified CSA C22.2 No. LR 53222 Certification file # 201527 FM Approved Class 3510, 3530 File # J.I. 1Y919.AF Commonwealth

More information

Pressure Switch for gas and air

Pressure Switch for gas and air Switch for gas and air GAO-A4 GMH-A4 GML-A4 UL Listed UL 353 File # MH 16628 CSA Certified CSA C22.2 No. 13 and No. 0 Certification file # 201527 FM Approved Class 3510, 3530 File # J.I. 1Y919.AF Commonwealth

More information

Fast Switching Valves

Fast Switching Valves Fast Switching Valves Ultra Fast and Highly Repeatable MH, MH3 and MH4 MH: Flow rate of 100 l/min and ms response MH3: Flow rate of 00 l/min and 3 ms response MH4: Flow rate of 400 l/min and 3.5 ms response

More information

2/2-Way Solenoid Control Valve

2/2-Way Solenoid Control Valve 2/2-Way Solenoid Control Valve Excellent range (1:200) Very good response Compact valve design Orifice sizes 0.05... 2.0 mm ort connection 1/8 or sub-base Type 2871 can be combined with Type 8605 Digital

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and

More information

BGA158 Series CE Approved Class A Shutoff Gas Valve

BGA158 Series CE Approved Class A Shutoff Gas Valve Installation Instructions BGA158 Issue Date August 24, 2011 BGA158 Series CE Approved Class A Shutoff Gas Valve Applications The BGA158 Series shutoff gas valve is an electrically operated gas valve that

More information

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm Dimensions M18x1 37 40 4 0102 24 LED Model Number Features 5 mm embeddable Usable up to SIL2 acc. to IEC 61508 Connection BN BU Accessories L+ L- EXG-18 Quick mounting bracket with dead stop BF 18 Mounting

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.

More information

BAPI Pressure Line of Products - FAQs

BAPI Pressure Line of Products - FAQs Table of Contents 1. Several manufacturers produce pressure transmitters, why should I purchase from BAPI?... p. 2 2. BAPI makes several styles of pressure transmitters. What are the features of each?...

More information

Gas Pressure Switch for DMV safety shutoff valves

Gas Pressure Switch for DMV safety shutoff valves Gas Pressure Switch for DMV safety shutoff valves GAO-A GMH-A GML-A UL Listed UL File # MH 668 CSA Certified CSA C. No. LR File # 07 FM Approved Class 0, 0 File # J.I. Y9A9.AF Commonwealth of Massachusetts

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 00 Model Number Features 5 mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,

More information

DX 3 RCDs. Technical data Nature and consequences of electrical risks Direct and indirect contact. Direct contacts

DX 3 RCDs. Technical data Nature and consequences of electrical risks Direct and indirect contact. Direct contacts RCDs Nature and consequences of electrical risks Direct and indirect contact All electrical risks for people are the result of direct or indirect contact. What are these contacts? And how can we protect

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 6 mm flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,

More information

Inductive slot sensor

Inductive slot sensor 0102 Model Number Features 3.5 mm slot width Usable up to SIL 3 acc. to IEC 61508 Nonferrous targets Application Danger! In safety-related applications the sensor must be operated with a qualified fail

More information

BGA158 Series CE Approved Class B Shutoff Gas Valve

BGA158 Series CE Approved Class B Shutoff Gas Valve Installation Instructions BGA158 Issue Date March 22, 2016 BGA158 Series CE Approved Class B Shutoff Gas Valve Applications The BGA158 Series shutoff gas valve is an electrically operated shutoff valve

More information

DPS-400 SERIES DPH-100 SERIES

DPS-400 SERIES DPH-100 SERIES 745 Dual Display Digital Pressure Sensor For Gas DPS-400 SERIES SERIES General terms and conditions... F- guide... P.699~ Related Information Glossary of terms... P.156~ General precautions... P.1566 PHOTO

More information

Dual Solenoid Gas Valve Installation

Dual Solenoid Gas Valve Installation Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing or servicing FLYNN Gas Products. Carefully follow all instructions in this bulletin and all instructions

More information

Relative pressure switch type 521

Relative pressure switch type 521 Relative pressure switch type 521 Pressure range 0... 2.5 600 bar The compact type 521 pressure switch is based upon the Huba Control developed thick film technology where the pressure measuring cell is

More information

TVS Diodes Axial Leaded 30 kw > 30KPA-HRA series. Features. 30 kw 8.0 W 400 A. -55 to 175 C. Notes: 8.0 C/W

TVS Diodes Axial Leaded 30 kw > 30KPA-HRA series. Features. 30 kw 8.0 W 400 A. -55 to 175 C. Notes: 8.0 C/W 3KPA-HRA Series RoHS Pb e3 Descriptions AGENCY Uni-directional Agency Approvals Maximum Ratings and Thermal Characteristics (T A =25 O C unless otherwise noted) Parameter Symbol Value Unit Peak Pulse Power

More information

Level sensing relative and absolute pressure transmitter type 712

Level sensing relative and absolute pressure transmitter type 712 Level sensing relative and absolute pressure transmitter type 712 Pressure range 0... 0.3-3 bar The level sensing pressure transmitter Type 712 is manufactured using an relative or absolute pressure measuring

More information

2/2-Way Solenoid Control Valve

2/2-Way Solenoid Control Valve 2/2-Way Solenoid Control Valve Excellent range (1:200) Very good response Compact valve design Orifice sizes 0.05... 2.0 mm Port connection 1/8 or sub-base Type 2871 can be combined with Type 8605 Digital

More information

LEVEL Transmitters. ) of the liquid column above it and the atmospheric pressure (P atm

LEVEL Transmitters. ) of the liquid column above it and the atmospheric pressure (P atm Hydrostatic level transmitters nivopress N GENERAL DESCRITION The NIVORESS N hydrostatic level transmitters are designed to measure the level of clean or contaminated liquids. The pressure sensor at the

More information

5KP-HR Series. TVS Diodes Axial Leaded 5 kw > 5KP-HR series. Description. Uni-directional

5KP-HR Series. TVS Diodes Axial Leaded 5 kw > 5KP-HR series. Description. Uni-directional 5KP-HR Series RoHS Pb e3 AGENCY Uni-directional Agency Approvals AGENCY FILE NUMBER E2353 Bi-directional Maximum Ratings and Thermal Characteristics (T A =25 O C unless otherwise noted) Parameter Symbol

More information

Current transformers Measurement devices from 5 to 5000 A

Current transformers Measurement devices from 5 to 5000 A Metering, monitoring & power quality trafo_108_a_1_cat Current transformers Three-phase CT trafo_012_a_1_cat The solution for > ndustry. > Service sector. Strong points trafo_077_b_1_cat trafo_010_a_1_cat

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 2 mm flush Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 2 mm Installation flush Output

More information

OPTIBAR P 1010 C Technical Datasheet

OPTIBAR P 1010 C Technical Datasheet Technical Datasheet Pressure transmitter with recessed diaphragm for general applications Wide variety thanks to modular design Measuring ranges up to 250 bar / 3750 psi High overload and temperature stability

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens AG 07 Overview Function U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/ Equipotential bonding Diaphragm The pressure

More information

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure General-purpose Limit Switch CSM_DA-_N_DS_E The Limit Switch with Better Seal, Shock Resistance, and Strength A double seal on the head, a complete gasket cover, and other features ensure a better seal

More information

Prewired position switches FA series

Prewired position switches FA series Prewired position switches Technical data Housing Made of metal, coated with baked epoxy powder 2 m wired cable with 5x0,5 mm 2 wires marked SEV and IMQ Protection degree: IP6 General data Ambient temperature:

More information

TABLE OF CONTENTS 2 TALAS DRYER 4 TALAS MEASURER 7 TALAS PORTABLE DRYER 9 TALAS LEAKER 11 TALAS STARTER 14 TALAS AUXILIARY 17 APPENDICES

TABLE OF CONTENTS 2 TALAS DRYER 4 TALAS MEASURER 7 TALAS PORTABLE DRYER 9 TALAS LEAKER 11 TALAS STARTER 14 TALAS AUXILIARY 17 APPENDICES TABLE OF CONTENTS 2 TALAS DRYER 4 TALAS MEASURER 7 TALAS PORTABLE DRYER 9 TALAS LEAKER 11 TALAS STARTER 14 TALAS AUXILIARY 17 APPENDICES ALL PICTURES SHOWN ARE FOR REFERENCE ONLY ACTUAL PRODUCT MAY VARY

More information

Current transformers. Measurement devices. 2 General Catalogue SOCOMEC. Measurement devices NEW. ÂÂEnergy efficiency

Current transformers. Measurement devices. 2 General Catalogue SOCOMEC. Measurement devices NEW. ÂÂEnergy efficiency NEW trafo_108_a_1_cat Three-phase CT trafo_010_a_1_cat trafo_077_b_1_cat trafo_012_a_1_cat ÂÂEnergy efficiency 0.2s We offer class 0.2s for your energy efficiency or MD applications. appli_294_a ÂÂFunction

More information

Short Form Brochure. Terminal Blocks &Accessories

Short Form Brochure. Terminal Blocks &Accessories Short Form Brochure Terminal Blocks &Accessories 1/2013 AVK - Screw Type Terminal Blocks Connection Systems SCREW CONNECTION : This is the most popular of all known methods of connection. Screw connection

More information

Monitoring device NTS 30

Monitoring device NTS 30 P R O D U C T I N F O R M A T I O N Electronic level- and temperature monitoring device Monitoring device NTS 30 Contents Description Description... 2 Operating... 3 Design and electrical data... 4 Circuit

More information