ANSI/TIA-568-C-2009: Balanced Twisted-Pair Telecommunications Cabling and Components Standard, dated August 2009

Size: px
Start display at page:

Download "ANSI/TIA-568-C-2009: Balanced Twisted-Pair Telecommunications Cabling and Components Standard, dated August 2009"

Transcription

1 3933 US Route 11 Cortland, NY 1345 Telephone: (67) Facsimile: (67) November 1, 217 Test Report Number: CRT-27 Project Number: TEST: Legrand North America Superior Essex 125 Eugene O Neill Drive 612 Powers Ferry Road New London, CT 632 Suite 15 Ph (86) Atlanta, GA 3339 Fax (86) Electrical transmission performance testing of a cabling configuration to the requirements of ANSI/-568-C.2 for Category 5e and the /IEC 1181 Edition 2.2 for Class D Channels. SAMPLE DESCRIPTION: The client supplied and tested a 4-Connector channel as illustrated below and referenced to as ncompass CAT 5e+ U/UTP Channel, 4-Connector, 1 meters (328 ft) Component Manufacturer Part Number Length/Qty Description 1 Superior PW52-H46-x8 7m (229.6 PowerWise Cable, 1G 4PPoE CMP 2 Superior PW52-H46-x8 2m (65.6 ft) PowerWise Cable, 1G 4PPoE CMP 3 Ortronics, Inc. OR-PHD5E6U24 2 C5e 24 Port Patch Panel 4 Ortronics, Inc. OR-HDJ5E 1 C5e High Density Jack 5 Ortronics, Inc OR- 1 Clarity C5e U/UTP 11 Block 6, 7, 8 Ortronics, Inc OR-MC5E9 3m (9.8 ft) / 1 C5e U/UTP Patch Cords STANDARDS USED: ANSI/-568-C-29: Balanced Twisted-Pair Telecommunications Cabling and Components Standard, dated August 29 /IEC 1181 Information Technology - Generic cabling for customer premises, Second edition dated September 22 including amendments up to Amendment 2, dated April 21 Page 1 of 2 This report is for the exclusive use of Intertek s Client and is provided pursuant to the agreement between Intertek and its Client. Intertek s responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only the sample tested. This report by itself does not imply that the material, product or service is or has ever been under an Intertek certification program. 8 Intertek Testing Services NA, Inc.

2 Legrand Test report number CRT-27 November 1, 217 SECTIONS USED: Section 6.2 of ANSI/-568-C: Channel transmission performance (6.2.1 to ) Section 6.4 of /IEC 1181: Channel transmission performance (Sections 6.4) AUTHORIZATION: The project was authorized by Mr. Rob Aekins RCDD, representing Legrand Data Communications Incorporated. EQUIPMENT LIST: The following equipment was employed in conducting the tests. Equipment used Model number Serial number Calibration date Calibration due date Agilent Technologies Network Analyzer E571B MY /26/217 7/26/218 Hewlett Packard Multimeter 3441A US /26/217 7/26/218 DATE OF TEST: August 18, 217 TEST REPORT REVISION HISTORY: First Issue: November 1, 217 Original Document RESULTS: See appendices A and B for the test results. CONCLUSION: The channel cabling configuration, as previously described and supplied by the client, was tested in accordance with the standards referred to herein, and did comply with the indicated applicable transmission requirements. The procedures and requirements from the standard were followed, and the testing was performed at the client s facility as part of their qualifications under Intertek s SAT program. Reviewed and Approved By: Antoine Pelletier Project Engineer Global Cabling Products Testing David Ayers Technician Global Cabling Products Testing Page 2 of 2 Intertek Testing Services NA, Inc.

3 Legrand Test report number CRT-27 November 1, 217 Appendix A Test results Internal (core) transmission characteristics This appendix contains 7 pages. Intertek Testing Services NA, Inc.

4 Report Number: CRT-27.xlsx Test Standards: ANSI/-568-C.2 and /IEC 1181 NEXT as measured from the TELECOMMUNICATIONS ROOM (TR) -2-1 _CH LIMIT _CH LIMIT PrC 13 PrC 12 PrC 14 PrC 23 PrC 24 PrC Case Freq Measured Calculated CH LIMIT Freq Calculated CH LIMIT Freq s n/a 2. n/a n/a 25. n/a n/a 3. n/a n/a 4. n/a n/a 5. n/a n/a 65. n/a NEXT as measured from the WORK AREA (WA) -2-1 _CH LIMIT _CH LIMIT PrC 13 PrC 12 PrC 14 PrC 23 PrC 24 PrC Case Freq Measured Calculated CH LIMIT Freq Calculated CH LIMIT Freq s n/a 2. n/a n/a 25. n/a n/a 3. n/a n/a 4. n/a n/a 5. n/a n/a 65. n/a Appendix A Page 1 of 7 Legrand

5 Report Number: CRT-27.xlsx Test Standards: ANSI/-568-C.2 and /IEC 1181 PSNEXT as measured from the TELECOMMUNICATIONS ROOM (TR) -2 _CH LIMIT CH LIMIT Case Freq s n/a 2. n/a n/a 25. n/a n/a 3. n/a n/a 4. n/a n/a 5. n/a n/a 65. n/a PSNEXT as measured from the WORK AREA (WA) -2 _CH LIMIT _CH LIMIT Case Freq s n/a 2. n/a n/a 25. n/a n/a 3. n/a n/a 4. n/a n/a 5. n/a n/a 65. n/a Appendix A Page 2 of 7 Legrand

6 Report Number: CRT-27.xlsx Test Standards: ANSI/-568-C.2 and /IEC 1181 RL as measured from the TELECOMMUNICATIONS ROOM (TR) _CH LIMIT _CH LIMIT -75 Case Freq Measured Calculated CH LIMIT Freq Calculated CH LIMIT Freq s n/a 2. n/a n/a 25. n/a n/a 3. n/a n/a 4. n/a n/a 5. n/a n/a 65. n/a RL as measured from the WORK AREA (WA) _CH LIMIT _CH LIMIT -75 Case Freq Measured Calculated CH LIMIT Freq Calculated CH LIMIT Freq s n/a 2. n/a n/a 25. n/a n/a 3. n/a n/a 4. n/a n/a 5. n/a n/a 65. n/a Appendix A Page 3 of 7 Legrand

7 Report Number: CRT-27.xlsx Test Standards: ANSI/-568-C.2 and /IEC 1181 ACRF -2 _CH LIMIT _CH LIMIT PrC12 PrC13-1 PrC14 PrC21 PrC23 PrC24 PrC31 PrC32-12 PrC34 PrC41 PrC42 PrC43-14 Case Freq Measured Calculated CH LIMIT Freq Calculated CH LIMIT Freq s n/a 2. n/a n/a 25. n/a n/a 3. n/a n/a 4. n/a n/a 5. n/a n/a 65. n/a PSACRF -2 _CH LIMIT _CH LIMIT -1 Case Freq s n/a 2. n/a n/a 25. n/a n/a 3. n/a n/a 4. n/a n/a 5. n/a n/a 65. n/a Appendix A Page 4 of 7 Legrand

8 Report Number: CRT-27.xlsx Test Standards: ANSI/-568-C.2 and /IEC 1181 TCL as measured from the TELECOMMUNICATIONS ROOM (TR) -2 _CH LIMIT -1 Case Freq n/a 37.4 n/a n/a s n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 2. n/a n/a n/a 25. n/a n/a n/a 3. n/a n/a n/a 4. n/a n/a n/a 5. n/a 65. n/a n/a 65. n/a TCL as measured from the WORK AREA (WA) -2 _CH LIMIT -1 Case Freq n/a 49.8 n/a n/a s n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 2. n/a n/a n/a 25. n/a n/a n/a 3. n/a n/a n/a 4. n/a n/a n/a 5. n/a 65. n/a n/a 65. n/a Appendix A Page 5 of 7 Legrand

9 Report Number: CRT-27.xlsx Test Standards: ANSI/-568-C.2 and /IEC 1181 ELTCTL as measured from the TELECOMMUNICATIONS ROOM (TR) -2 _CH LIMIT -1 Case Freq n/a 34.2 n/a n/a s n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 62.5 n/a n/a n/a 1. n/a n/a n/a 2. n/a n/a n/a 25. n/a n/a n/a 3. n/a n/a n/a 4. n/a n/a n/a 5. n/a 65. n/a n/a 65. n/a ELTCTL as measured from the WORK AREA (WA) -2 _CH LIMIT -1 Case Freq n/a 43.4 n/a n/a s n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 62.5 n/a n/a n/a 1. n/a n/a n/a 2. n/a n/a n/a 25. n/a n/a n/a 3. n/a n/a n/a 4. n/a n/a n/a 5. n/a 65. n/a n/a 65. n/a Appendix A Page 6 of 7 Legrand

10 Report Number: CRT-27.xlsx Test Standards: ANSI/-568-C.2 and /IEC 1181 INSERTION LOSS (ATTN) Case _CH LIMIT _CH LIMIT -5 Freq Measured Calculated CH LIMIT Freq Calculated CH LIMIT Freq s n/a 2. n/a n/a 25. n/a n/a 3. n/a n/a 4. n/a n/a 5. n/a n/a 65. n/a DC Loop Resistance (Ohms) ChnlLimit Max Min DC Resistance Unbalance (%) ChnlLimit Max Min GLOSSARY of TERMS Calculated : s: Frequency : LIMIT : Measured : Freq: Freq (): Case: ACR / PSACR: The minimum difference in db between the measured value and the LIMIT value at the specifed frequency point for all tested pairs (Calculate@1MHz = Measured@1MHz - LIMIT@1MHz ). Specific reference points of interest in MHz within the swept frequencies. A specific frequency point in megahertz (MHz) for which the data indicated is applicable. The calculated response LIMIT in db at the indicated frequency point as calculated using applicable equations defined by the appropriate standard. The worst case measured response in db at the frequency indicated for all tested pairs. The band of measured values from 1 MHz to the upper frequency LIMIT as defined by the category of test. The minimum margin in db detected across the Frequency band. A composite value calculated from the maximum response of each pair or pair combination at a given frequency. (Case 1MHz = Max( 1MHz, 1MHz, 1MHz, 1MHz ) etc. If Provided are for reference only. Limit line(s) are provided for reference and are calculated as the difference between the applicable NEXT Loss and Insertion loss limits (ACR limit = NEXT limit - IL limit ). Appendix A Page 7 of 7 Legrand

11 Legrand Test report number CRT-27 November 1, 217 Appendix B Test results ACR transmission performance provided for reference ONLY This appendix contains 2 pages. Intertek Testing Services NA, Inc.

12 Report Number: CRT-27.xlsx Test Standards: ANSI/-568-C.2 and /IEC _CH LIMIT Pair-to-Pair ACR as measured from the TELECOMMUNICATIONS ROOM (TR) Case _CH LIMIT PrC 12 PrC 13 PrC 14 Freq PrC 23 PrC 24 s PrC n/a 2. n/a n/a 25. n/a n/a 3. n/a n/a 4. n/a n/a 5. n/a NOTE: Limit line/values provided for reference ONLY and are extrapolated n/a 65. n/a from NEXT Loss and IL limit requirements. ACR limit = NEXT limit - IL limit Pair-to-Pair ACR as measured from the WORK AREA (WA) 4 _CH LIMIT _CH LIMIT PrC 12 PrC 13 PrC 14 PrC 23 PrC 24 PrC Case Freq s n/a 2. n/a n/a 25. n/a n/a 3. n/a n/a 4. n/a n/a 5. n/a n/a 65. n/a Appendix B Page 1 of 2 Legrand

13 Report Number: CRT-27.xlsx Test Standards: ANSI/-568-C.2 and /IEC 1181 Power Sum (PS) ACR as measured from the TELECOMMUNICATIONS ROOM (TR) 4 _CH LIMIT Case _CH LIMIT Freq s n/a 2. n/a n/a 25. n/a n/a 3. n/a n/a 4. n/a n/a 5. n/a NOTE: Limit line/values provided for reference ONLY and are extrapolated n/a 65. n/a from PSNEXT Loss and IL limit requirements. psacr limit = psnext limit - IL limit Power Sum (PS) ACR as measured from the WORK AREA (WA) 4 _CH LIMIT _CH LIMIT -12 Case Freq s n/a 2. n/a n/a 25. n/a n/a 3. n/a n/a 4. n/a n/a 5. n/a n/a 65. n/a Appendix B Page 2 of 2 Legrand

Test Report Number: CRT-026 Project Number:

Test Report Number: CRT-026 Project Number: 3933 US Route 11 Cortland, NY 1345 Telephone: (67) 753-6711 Facsimile: (67) 758-3659 www.intertek.com November 1, 217 Test Report Number: 1246639CRT-26 Project Number: 1246639 Legrand North America Superior

More information

ANSI/TIA-568-C : Balanced Twisted-Pair Telecommunications Cabling and Components Standard, dated August 2009

ANSI/TIA-568-C : Balanced Twisted-Pair Telecommunications Cabling and Components Standard, dated August 2009 3933 US Route 11 Cortland, NY 1345 Telephone: (67) 753-6711 Facsimile: (67) 758-3659 www.intertek.com April 4, 213 Test Report Number: 33592CRT-99 Project Number: 33592 Legrand North America 125 Eugene

More information

Test Report Number: CRT-095 Project Number:

Test Report Number: CRT-095 Project Number: 3933 US Route 11 Cortland, NY 1345 Telephone: (67) 753-6711 Facsimile: (67) 758-3659 www.intertek.com April 17, 213 Test Report Number: 33592CRT-95 Project Number: 33592 Legrand North America 125 Eugene

More information

SAR COMPLIANCE REPORT

SAR COMPLIANCE REPORT Stanley Black & Decker, Inc. SAR COMPLIANCE REPORT Report Type: FCC SAR assessment report Model: MHL600 REPORT NUMBER: 180501586SHA-002 ISSUE DATE: Aug 30, 2018 DOCUMENT CONTROL NUMBER: TTRFFCCSAR-01_V1

More information

Tests Completed: Test Date(s): Section Results General Requirements (All Protectors) Impact Protector Requirements (Z87+)

Tests Completed: Test Date(s): Section Results General Requirements (All Protectors) Impact Protector Requirements (Z87+) 3/7/2014 Sabastian Barriga Vicsa Safety Casa Matriz Pintor Cicarelli 683-San Joaquin, Chile Intertek Test Report Number: G101529224CRT-004 Dear Sabastian: Intertek has completed the evaluation of your

More information

TEST REPORT 545 EAST ALGONQUIN RD., SUITE F ARLINGTON HEIGHTS, IL USA. Project No. G August 12, 2013 Page 1 of 9

TEST REPORT 545 EAST ALGONQUIN RD., SUITE F ARLINGTON HEIGHTS, IL USA. Project No. G August 12, 2013 Page 1 of 9 TEST REPORT 545 EAST ALGONQUIN RD., SUITE F ARLINGTON HEIGHTS, IL 60005 USA Project No. G101297091 August 12, 2013 Page 1 of 9 REPORT NO. 101297091CHI-001 INGRESS PROTECTION (IP66) AND HOSEDOWN TESTING

More information

Intertek Testing Services Taiwan Ltd.

Intertek Testing Services Taiwan Ltd. 1) The testing results relate only to the items tested. Page 2 of 21 2) The test report shall not be reproduced except in full, without written approval of the laboratory. 3) This test report only allows

More information

QUANEX BUILDING PRODUCTS TEST REPORT

QUANEX BUILDING PRODUCTS TEST REPORT QUANEX BUILDING PRODUCTS TEST REPORT SCOPE OF WORK DUAL PANE INSULATING GLASS UNIT PERFORMANCE & GAS EVALUATION REPORT NUMBER H1690.01-119-28 R0 TEST DATE(S) 05/24/17-09/28/17 ISSUE DATE 10/18/17 RECORD

More information

Test Report #: Date: June 21, 2005

Test Report #: Date: June 21, 2005 CERTIFICATE #2316.01 Test Report #: 1979-2 Date: June 21, 2005 Issued To: Bill Burks American Power Conversion 85 Rangeway Road North Billerica, MA 01862 USA 978-670-2440 Product Name/Description Uninterruptable

More information

Model SM/PL Series. Calibration Guide. Precision Loads. Anritsu Company 490 Jarvis Drive Morgan Hill, CA USA

Model SM/PL Series. Calibration Guide. Precision Loads. Anritsu Company 490 Jarvis Drive Morgan Hill, CA USA Calibration Guide Model SM/PL Series Precision Loads Anritsu Company 490 Jarvis Drive Morgan Hill, CA 95037-2809 USA Part Number: 10100-00056 Revision: B Published: January 2010 Copyright 2009-2010 Anritsu

More information

Code Compliance Research Report CCRR-0145

Code Compliance Research Report CCRR-0145 Code Compliance Research Report CCRR-0145 Issue Date: 11-16-2009 Revision Date: 11-29-2018 Renewal Date: 11-18-2019 DIVISION: 05 - Metals Section: 05 50 00 Metal Fabrications Marshall Stamping Company

More information

The above item, as tested, is considered to comply with the above specifications. PAGE 1 OF 6

The above item, as tested, is considered to comply with the above specifications. PAGE 1 OF 6 APPLICANT: Suck UK Limited 31 Regent Studios 8 Andrews Road London E8 4QN DATE: 17 th January 2014 For the attention of Emma SAMPLE DESCRIPTION: Bottlelight REFERENCE / STYLE NO.: SK LIGHTBOTTLE 1 RETAILER:

More information

CADWELL INDUSTRIES, INC. TEST REPORT FOR THE ELECTRONEURODIAGNOSTIC MONITORING SYSTEM, EASY WIRELESS EEG

CADWELL INDUSTRIES, INC. TEST REPORT FOR THE ELECTRONEURODIAGNOSTIC MONITORING SYSTEM, EASY WIRELESS EEG TESTING CERT #803.01, 803.02, 803.05, 803.06 CADWELL INDUSTRIES, INC. TEST REPORT FOR THE ELECTRONEURODIAGNOSTIC MONITORING SYSTEM, EASY WIRELESS EEG FCC PART 15 SUBPART B SECTIONS 15.107 AND 15.109 CLASS

More information

Code Compliance Research Report CCRR-0145

Code Compliance Research Report CCRR-0145 Code Compliance Research Report CCRR-0145 Issued: 11-16-2009 Renewal Due: 11-18-2018 Revised: 11-28-2017 DIVISION: 05 - Metals Section: 05 50 00 Metal Fabrications MARSHALL STAMPING COMPANY 355 Glade Mills

More information

IBDN BIX Cross-Connect System

IBDN BIX Cross-Connect System IBDN BIX Cross-Connect System BIX Connectors BIX Modular Jack Connectors BIX Mounts BIX Patch Cords Labels and Management Accessories Installation and Testing Tools For what s coming next. Cross-connect

More information

GigaBIX Multi System 케이블콘 ( 주 ) 기술지원팀 :: 콘넥터문의 케이블문의 Termination Kits and Basic Components

GigaBIX Multi System 케이블콘 ( 주 ) 기술지원팀 :: 콘넥터문의 케이블문의 Termination Kits and Basic Components C O M M E R C I A L N E T W O R K I N G C O P P E R 15.9 Termination Kits and Basic Components AX101985 GigaBIX Rack Mount Termination Kit, 48-port GigaBIX Termination Kits The GigaBIX Termination Kits

More information

Qualification of Fastrak & First Gen Product to Railway applications Shock and Vibration Standard EN 61373

Qualification of Fastrak & First Gen Product to Railway applications Shock and Vibration Standard EN 61373 Qualification of Fastrak & First Gen Product to Railway applications Shock and Vibration Standard EN 61373 (Governing Standard BS EN 5155 Railway Applications Electronic equipment used on rolling stock)

More information

@h..p. lntertek. IECEx Certificate of Conformity

@h..p. lntertek. IECEx Certificate of Conformity ECEx Certificate of Conformity NTERNATONAL ELECTROTECHNCAL COMMSSON EC Certification Scheme for Explosive Atmospheres for rules and details of the ECElC Scheme visit www.iecex.com Certificate No.: { ECclC

More information

EUROPEAN pr I-ETS TELECOMMUNICATION September 1995 STANDARD

EUROPEAN pr I-ETS TELECOMMUNICATION September 1995 STANDARD INTERIM DRAFT EUROPEAN pr I-ETS 300 671 TELECOMMUNICATION September 1995 STANDARD Source: ETSI TC-TM Reference: DI/TM-01029 ICS: 33.180.20 Key words: Optical transmission, optical connectors Transmission

More information

SMARTen STP Patch Cords Features

SMARTen STP Patch Cords Features Features Patch Cords are used in the work area and cross-connect generic cabling applications Comprise a length of eight-wire flexible patch cable, terminated with two eight-position RJ-45 plugs at each

More information

IEC Test Report for mini-box.com Report No. NF September 29, Test Report

IEC Test Report for mini-box.com Report No. NF September 29, Test Report Test Report Report No NF0693-1 Client mini-box.com 4031 Clipper Ct Fremont, CA 94538 Items tested WRAP-BOX-2A-1E Specifications IEC 60529 IP65 Rating Results As detailed within this report Prepared by

More information

A Closer Look at Fiber Optic Cable Assemblies

A Closer Look at Fiber Optic Cable Assemblies A Closer Look at Fiber Optic Cable Assemblies Many network performance problems occurring at the physical layer are directly related to cable assembly quality. In fact, the overall performance and reliability

More information

210 Series Transmitter with External Electrochemical Sensor

210 Series Transmitter with External Electrochemical Sensor 210 Series Transmitter with External Electrochemical Sensor INSTRUCTIONS Installation and Operation of the AMC-210 Series Transmitter with External Electrochemical Sensor IMPORTANT: Please read these installation

More information

FTC130 Transmitter. Operating Manual

FTC130 Transmitter. Operating Manual Seite 1 von 11 FTC130 Transmitter Fast Thermal Conductivity Analyzer Operating Manual 1.09KD180724CWI1V05 Messkonzept GmbH Seite 2 von 11 1. Intended Use... 3 2. Description... 4 3. Measuring gases and

More information

ST Connectors & Adapters

ST Connectors & Adapters Features & Benefits High performance singlemode and multimode pre-polished ferrules ST* compatible bayonet coupling Field installable Standard crimp and crimpless screw type KEVLAR retention Variety of

More information

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6 P9000 High accuracy through digital compensation High thermal stability Rugged stainless steel construction Ideal for test stands High burst pressure limit DESCRIPTION The P9000 Series is a range of advanced,

More information

ASP (QMS) + ASP (QFS) PCIe GEN 2 AND GEN 3 CHANNEL CHARACTERIZATION USING RTD S DIVER 2 TEST PLATFORM REVISION DATE: 02/21/2012 1

ASP (QMS) + ASP (QFS) PCIe GEN 2 AND GEN 3 CHANNEL CHARACTERIZATION USING RTD S DIVER 2 TEST PLATFORM REVISION DATE: 02/21/2012 1 ASP 129637 03 (QMS) + ASP 129646 03 (QFS) PCIe GEN 2 AND GEN 3 CHANNEL CHARACTERIZATION USING RTD S DIVER 2 TEST PLATFORM REVISION DATE: 02/21/2012 1 PROJECT SCOPE Several years back, QMS/QFS 0.6 mated

More information

CTAG:b9927e36a4b3f34a9138ce0bb2426b22 Certificate of Calibration

CTAG:b9927e36a4b3f34a9138ce0bb2426b22 Certificate of Calibration CTAG:b997e6abfa98cebb6b Certificate of Calibration Data Type: FOUND-LEFT Certificate No: 79 Instrument Description Manufacturer Model Serial Number Inventory Number CABLE ANALYZER FLUKE NETWORKS DTX-8

More information

GEMS SENSORS & CONTROLS

GEMS SENSORS & CONTROLS GEMS SENSORS & CONTROLS OPERATING & INSTALLATION INSTRUCTIONS 31XX / 32XX SERIES PLEASE READ CAREFULLY BEFORE INSTALLING Part Number: 560550-0076 Issue: E INTRODUCTION Series 3100/3200 high output pressure

More information

Successful completion of the course leads to the award of the Technical Training Solutions Certificate of Competence 510: Instrumentation.

Successful completion of the course leads to the award of the Technical Training Solutions Certificate of Competence 510: Instrumentation. INSTRUMENTATION COURSE 510: 3 DAYS: Max 8 Candidates This course covers the key aspects of industrial instrumentation and is designed to enable maintenance personnel to carry out commissioning, calibration

More information

8. Tracking, Marking and Locating. 8. Tracking, Marking & Locating your FTTx Network

8. Tracking, Marking and Locating. 8. Tracking, Marking & Locating your FTTx Network 8. Tracking, Marking & Locating your FTTx Network Single Family Units Outside Plant: Aerial Fibre Pedestal Outside Plant: Buried Fibre 3M Telecommunications provides you with solutions to distribute your

More information

GAS TRANSPORTER S REQUIREMENTS FOR GAS MEASUREMENT SYSTEMS CONNECTED TO THE NATIONAL GRID GAS NETWORK

GAS TRANSPORTER S REQUIREMENTS FOR GAS MEASUREMENT SYSTEMS CONNECTED TO THE NATIONAL GRID GAS NETWORK SPECIFICATION FOR GAS TRANSPORTER S REQUIREMENTS FOR GAS MEASUREMENT SYSTEMS CONNECTED TO THE NATIONAL GRID GAS NETWORK J510 ( Rev 04/06 ) OCTOBER 2005 . CONTENTS Page FOREWORD BRIEF HISTORY iii iii INTRODUCTION

More information

MOTOROLA PTP 800 LICENSED ETHERNET MICROWAVE

MOTOROLA PTP 800 LICENSED ETHERNET MICROWAVE HIGH-THROUGHPUT COMMUNICATIONS FOR MULTI-SERVICE NETWORKS MOTOROLA PTP 800 LICENSED ETHERNET MICROWAVE PTP 800 solutions can efficiently and affordably transport the data, voice and video that your bandwidth-intensive

More information

Intertek Test Report No CRT-003 Project No. G

Intertek Test Report No CRT-003 Project No. G 3933 US Route 11 Cortland, NY 13045 Telephone: (607) 753-6711 Facsimile: (607) 753-1045 www.intertek.com Intertek Project No. G100413407 Mr. Steve Turek Phone: 952-447-6064 Wind Turbine Industries, Corporation

More information

SMB/SMC Coaxial Connectors

SMB/SMC Coaxial Connectors The Amphenol SMB/SMC subminiature coaxial connectors with 50 ohm impedance are for applications to 4 GHz (SMB) or 10 GHz (SMC). Generally less expensive then SMA, these connectors are used primarily in

More information

BASnet LightiView Install Guide

BASnet LightiView Install Guide BASnet LightiView 1025 Cobb Place Blvd Suite 100 Kennesaw, GA 30144 800-241-9173 www.triateklighting.com ATTENTION This section serves as a notice of the immediate or potential dangers involved when working

More information

CMA4000 Specifications

CMA4000 Specifications CMA4000 Specifications Display Mass Storage VGA LCD Display (8.4 color or 8.2 monochrome) Up to 125 traces internal storage. Over 65,000 traces with optional hard drive. Up to 180 traces for a standard

More information

CTAG:e43bda4f8e48714fbb aefb192 Certificate of Calibration

CTAG:e43bda4f8e48714fbb aefb192 Certificate of Calibration CTAG:ebdaf8e87fbb5996aefb9 Certificate of Calibration Data Type: FOUND-LEFT Certificate No: 6858 Instrument Description Manufacturer Model Serial Number Inventory Number CABLE ANALYZER FLUKE NETWORKS DTX-8

More information

Optical Time Domain Reflectometer. Operating System 2 Windows XPe Windows XP Pro with desktop option 256 MB

Optical Time Domain Reflectometer. Operating System 2 Windows XPe Windows XP Pro with desktop option 256 MB CMA 4500 Series Optical Time Domain Reflectometer The CMA 4500 continues NetTest s tradition as the industry s premier OTDR solution designed with the high performance and scalability necessary to meet

More information

Cabling Services (price per pull) Zone 1 Zone 2 Zone 3 Zone 4 Zone 5

Cabling Services (price per pull) Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Cabling Labor Only C. Link, LLC Appendix C Pricing Index Cat 5e cable - installed, terminated, tested and labeled including wall plate, jack and certification report. 0-150 Feet $100.00 $100.00 151-300

More information

SIL Safety Manual. ULTRAMAT 6 Gas Analyzer for the Determination of IR-Absorbing Gases. Supplement to instruction manual ULTRAMAT 6 and OXYMAT 6

SIL Safety Manual. ULTRAMAT 6 Gas Analyzer for the Determination of IR-Absorbing Gases. Supplement to instruction manual ULTRAMAT 6 and OXYMAT 6 ULTRAMAT 6 Gas Analyzer for the Determination of IR-Absorbing Gases SIL Safety Manual Supplement to instruction manual ULTRAMAT 6 and OXYMAT 6 ULTRAMAT 6F 7MB2111, 7MB2117, 7MB2112, 7MB2118 ULTRAMAT 6E

More information

SAILING INSTRUCTIONS FOR THE BAKEWELL-WHITE 8 CLASS STATE CHAMPIONSHIP SERIES

SAILING INSTRUCTIONS FOR THE BAKEWELL-WHITE 8 CLASS STATE CHAMPIONSHIP SERIES SAILING INSTRUCTIONS FOR THE BAKEWELL-WHITE 8 CLASS STATE CHAMPIONSHIP SERIES 2018-2019 Saturday 3 rd November 2018 Races 1 & 2 Saturday 1 st December 2018 Races 3 & 4 Saturday 15 th December 2018 Race

More information

Track and Field Interface

Track and Field Interface Track and Field Interface Quick Guide ED-14511 Rev 4 5 June 2007 ED-14511 P-1173 Rev 4 5 June 2007 Please fill in the information below for your display; use it for reference when calling Daktronics for

More information

YT-3300 / 3301 / 3302 / 3303 / 3350 / 3400 /

YT-3300 / 3301 / 3302 / 3303 / 3350 / 3400 / Smart positioner YT-3300 / 3301 / 3302 / 3303 / 3350 / 3400 / 3410 / 3450 Series SIL Safety Instruction. Supplement to product manual July. 2015 YTC Ver 1.06 1 Table of contents 1 Introduction... 3 1.1

More information

COPPER PRODUCT LINE CARD. For product specifications and instructions please visit

COPPER PRODUCT LINE CARD. For product specifications and instructions please visit COPPER PRODUCT LINE CARD For product specifications and instructions please visit www.wirewerks.com U/UTP -PAIR HORIZONT DISTRIBUTION CABLES CATA U/UTP Series Cables CATA - 0- X YY - L0 000 ft (0 meters)

More information

ISO INTERNATIONAL STANDARD. Natural gas Measurement of properties Volumetric properties: density, pressure, temperature and compression factor

ISO INTERNATIONAL STANDARD. Natural gas Measurement of properties Volumetric properties: density, pressure, temperature and compression factor INTERNATIONAL STANDARD ISO 15970 First edition 2008-06-15 Natural gas Measurement of properties Volumetric properties: density, pressure, temperature and compression factor Gaz naturel Mesurage des caractéristiques

More information

Test Summary Report Giraffe 2.0 Hybrid Wind-Solar Power Station - for wind: according to IEC Annex M - for solar: measurement report

Test Summary Report Giraffe 2.0 Hybrid Wind-Solar Power Station - for wind: according to IEC Annex M - for solar: measurement report Contact person Tanja Tränkle 2016-06-29 4P05805-R01 rev. 1 1 (7) Safety +46 10 516 57 19 Tanja.Trankle@sp.se Innoventum AB Morgan Widung / Marcus Ulmefors Turning Torso office 275 Lilla Varvsgatan 14 211

More information

Evaluating the Design Safety of Highway Structural Supports

Evaluating the Design Safety of Highway Structural Supports Evaluating the Design Safety of Highway Structural Supports by Fouad H. Fouad and Elizabeth A. Calvert Department of Civil and Environmental Engineering The University of Alabama at Birmingham Birmingham,

More information

Advertising Opportunities

Advertising Opportunities 2011 Advertising Opportunities Souvenir Programs The Calgary Stampede s two souvenir programs are premiere publications that include everything consumers need to know about the rodeo and the evening show.

More information

Model GFC 7000T CO 2 Analyzer (Addendum to GFC 7000TA Manual, PN 07272)

Model GFC 7000T CO 2 Analyzer (Addendum to GFC 7000TA Manual, PN 07272) Manual Addendum Model GFC 7000T CO 2 Analyzer (Addendum to GFC 7000TA Manual, PN 07272) P/N M07273 DATE 06/11/13 TELEDYNE ELECTRONIC TECHNOLOGIES Analytical Instruments 16830 Chestnut Street City of Industry,

More information

Table of Contents. Version 5.1. Mounting Hardware 9-10 Aluminum 9 Plastic 9 Plastic & Aluminum 10

Table of Contents. Version 5.1. Mounting Hardware 9-10 Aluminum 9 Plastic 9 Plastic & Aluminum 10 Version 5.1 Table of Contents Specifications 2-4 Technical Specs 2 Colors 3 Physical Specifications 4 Mounting Hardware 9-10 Aluminum 9 Plastic 9 Plastic & Aluminum 10 Part Number Naming Convention 5 Packaging

More information

PTP 800 SPLIT-MOUNT SOLUTION

PTP 800 SPLIT-MOUNT SOLUTION TM PTP 800 SPLIT-MOUNT SOLUTION LICENSED ETHERNET MICROWAVE FOR MULTI-SERVICE NETWORKS Cambium Point-to-Point (PTP) 800 Licensed Ethernet Microwave Solutions can efficiently and affordably transport the

More information

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features Design Features Rigid metallic construction. Maximum pressure of 1000 psig (70 bars). Leak integrity 1 x 10-7 of helium. NIST traceable certification. Built-in tiltable LCD readout. 0-5 Vdc and 4-20 ma

More information

T EK-SUB 4800C 19 mm Submersible Level Transmitter

T EK-SUB 4800C 19 mm Submersible Level Transmitter Technology Solutions T EK-SUB 4800C 19 mm Submersible Level Transmitter Instruction Manual Document Number: IM-4800C www.tek-trol.com Table of Contents 1 Safety Instructions... 2 1.1 Intended Use... 2

More information

New Thinking in Control Reliability

New Thinking in Control Reliability Doug Nix, A.Sc.T. Compliance InSight Consulting Inc. New Thinking in Control Reliability Or Your Next Big Headache www.machinerysafety101.com (519) 729-5704 Control Reliability Burning Questions from the

More information

Building Official's Guide to Duct Testing based on 2009 IECC

Building Official's Guide to Duct Testing based on 2009 IECC Why test ducts? Leaky ducts pose health, safety and comfort problems and account for about 25% of the total energy lost in a typical house. Because it s by far the most cost effective way to save energy

More information

WIREMOLD Eclipse Series Raceways

WIREMOLD Eclipse Series Raceways Small Nonmetallic Raceway Systems For Communications and Power pplications WIREMOLD Eclipse Series Raceways Eclipse PN03, PN05, and PN10 Series Raceways are single compartment raceways designed for communication

More information

HLM-2000-TX Gas Transmitter User Manual

HLM-2000-TX Gas Transmitter User Manual HLM-2000-TX Gas Transmitter User Manual Technical Support Continental North America Toll Free 1-(800) 387-9487 Ph: +1 (905) 829-2418 Fx: +1 (905) 829-4701 A Product of Arjay Engineering Ltd. Oakville,

More information

ESB TONAL NOISE ASSESSMENT. 30 May West Offaly Power Station. Report Author: Stephen Kearney

ESB TONAL NOISE ASSESSMENT. 30 May West Offaly Power Station. Report Author: Stephen Kearney Allegro Acoustics Limited, Unit 2A Riverside, Tallaght Business Park, Tallaght, Dublin 24 Tel/Fax: +353 (0) 1 4140485 ESB West Offaly Power Station TONAL NOISE ASSESSMENT 30 May 2016 Report Author: Stephen

More information

Inspection and Testing Pocket Notes

Inspection and Testing Pocket Notes Inspection and Testing Pocket Notes of Initial Verification Periodic Inspection Purpose of Information required by inspector 1. All equipment is correct type and complies with relevant British Standard

More information

HLM-2000-TX Gas Transmitter User Manual

HLM-2000-TX Gas Transmitter User Manual HLM-2000-TX Gas Transmitter User Manual Technical Support Continental North America Toll Free 1-(800) 387-9487 Ph: +1 (905) 829-2418 Fx: +1 (905) 829-4701 A Product of Arjay Engineering Ltd. Oakville,

More information

Cooling NI Single-Board RIO Systems Appendix: Reference Examples NI sbrio-9605/6

Cooling NI Single-Board RIO Systems Appendix: Reference Examples NI sbrio-9605/6 Cooling NI Single-Board RIO Systems Appendix: Reference Examples NI sbrio-9605/6 6/28/2012 Copyright 2012 National Instruments www.ni.com 1. NI sbrio-9606 General Setup... 3 2. Example A NI sbrio-9606,

More information

OPERATING INSTRUCTIONS FOR MODEL VSBX

OPERATING INSTRUCTIONS FOR MODEL VSBX OPERATING INSTRUCTIONS FOR MODEL VSBX-314 www.varsityscoreboards.com 1 Table of Contents CONTROLLER DEFINITIONS... 3 COMMUNICATION CABLES... 4 Connecting a Hard Wired Cable... 4 GETTING STARTED... 5 CHANGING

More information

Calibration Summary of Test Report No.: Sample

Calibration Summary of Test Report No.: Sample Calibration Summary of Test Report No.:30043 Rion Type: NL52/EX Serial no: 00732122 Customer: Scantek, Inc. Address: 6430 Dobbin Rd., Suite C, Columbia MD, 21045 Contact Person: Mariana Buzduga Phone No.:

More information

tr-- CALIBRATION CERTIFICATE Calibration Laboratory of Schmid & Partner Engineering AG Zeughausstrasse 43, 8004 Zurich, Switzerland DSGHzV2 - SN:1006

tr-- CALIBRATION CERTIFICATE Calibration Laboratory of Schmid & Partner Engineering AG Zeughausstrasse 43, 8004 Zurich, Switzerland DSGHzV2 - SN:1006 Calibration Laboratory of Schmid & Partner Engineering AG Zeughausstrasse 43, 8004 Zurich, Switzerland s Schweizerischer Kalibrierdienst C Service suisse d'etalonnage Servizio svizzero di taratura S Swiss

More information

Power Backoff. George Zimmerman, Solarflare Albert Vareljian, Keyeye Jose Tellado, Teranetics

Power Backoff. George Zimmerman, Solarflare Albert Vareljian, Keyeye Jose Tellado, Teranetics Power Backoff George Zimmerman, Solarflare Albert Vareljian, Keyeye Jose Tellado, Teranetics Agenda Filling in the TBDs Effect of the PSD mask Model refinements Worst-case margins 2 Filling in the TBDs

More information

ISO INTERNATIONAL STANDARD. Natural gas Calculation of compression factor Part 2: Calculation using molar-composition analysis

ISO INTERNATIONAL STANDARD. Natural gas Calculation of compression factor Part 2: Calculation using molar-composition analysis INTERNATIONAL STANDARD ISO 12213-2 Second edition 2006-11-15 Natural gas Calculation of compression factor Part 2: Calculation using molar-composition analysis Gaz naturel Calcul du facteur de compression

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION TECHNICAL SPECIFICATION IEC TS 61245 Edition 2.0 2015-03 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on d.c. systems INTERNATIONAL ELECTROTECHNICAL COMMISSION ICS

More information

Instruction and Maintenance Manual

Instruction and Maintenance Manual Instruction and Maintenance Manual GRYF OXY Z 02/100/2 E Contact GRYF HB, spol. s r.o. Cechova 314 Havlickuv Brod 580 01 tel.: +420 569 426 627 fax: +420 569 426 627 Czech Republic www.gryf.eu Technical

More information

50 WATT OPERATION MANUAL

50 WATT OPERATION MANUAL 50 WATT OPERATION MANUAL Congratulations on the purchase of your new RANDALL THRASHER SERIES Amplifier! We at Randall Amplification appreciate that you chose the Thrasher 50w head Amplifier and wish you

More information

Deep Submersible Level Transducer Series 300DS

Deep Submersible Level Transducer Series 300DS KPSI Transducers Deep Submersible Level Transducer Series 300DS FEATURES! Custom Level Ranges up to 4614 ft (1408 m) H 2 O! Accuracy of ±0.5% FS! Analog Outputs of 4-20 ma or 0-5 VDC! Welded 316 SS Construction!

More information

Rigel 601 CHECKBOX. Instruction Manual. 348A551 Issue 2.0. April Seaward Electronic Ltd. Issue 2.0

Rigel 601 CHECKBOX. Instruction Manual. 348A551 Issue 2.0. April Seaward Electronic Ltd. Issue 2.0 Rigel 601 CHECKBOX Instruction Manual 348A551 Issue 2.0 April 2006 2006 Seaward Electronic Ltd. Issue 2.0 Limited Warranty & Limitation of Liability Rigel Medical guarantees this product for a period of

More information

DeltaSpan Pressure Transmitters LD10 Series Owner s Manual

DeltaSpan Pressure Transmitters LD10 Series Owner s Manual Warranty, Service & Repair To register your product with the manufacturer, fill out the enclosed warranty card and return it immediately to: Flowline Inc. 10500 Humbolt Street Los Alamitos, CA 90720. If

More information

MCQ Gas Blender 100 Series 3 Channels Gas Mixer

MCQ Gas Blender 100 Series 3 Channels Gas Mixer Channels Gas Mixer Revision 1.8 October 2016 High Performance Digital Gas flow Gas Dilutor Blender & Gas for Mixing flow Mixing Gases System and Calibration Routines Technical Data Sheet Lab in a box From

More information

Instruction and Maintenance Manual

Instruction and Maintenance Manual Instruction and Maintenance Manual GRYF OXY ZM 02/100/2 E Contact GRYF HB, spol. s r.o. Cechova 314 Havlickuv Brod 580 01 tel.: +420 569 426 627 fax: +420 569 426 627 www.gryf.eu ver.: 11.2.2015 OEM module

More information

SAPCON. User Manual. Capacitance Continuous Level Indicator. . Introduction. . General Description. . Principle of Operation. .

SAPCON. User Manual. Capacitance Continuous Level Indicator. . Introduction. . General Description. . Principle of Operation. . User Manual Capacitance Continuous Level Indicator Comprehensive User s Manual. Introduction. General Description. Principle of Operation. Specifications. Connection Diagrams. Quick Calibration Chart.

More information

Design Features. General Description

Design Features. General Description Model thermal Mass Flow Controllers are designed to indicate and control set flow rates of gases. The combines the characteristics and accuracy of conventional mass flow devices into a unique compact design

More information

Traffic Impact Analysis Walton Acres at Riverwood Athletic Club Clayton, NC

Traffic Impact Analysis Walton Acres at Riverwood Athletic Club Clayton, NC Traffic Impact Analysis Walton Acres at Riverwood Athletic Club Clayton, NC 1. TABLE OF CONTENTS INTRODUCTION...1 1.1. Site Location and Study Area...1 1.2. Proposed Land Use and Site Access...2 1.3.

More information

P900. P900, Datenblatt Seite 1 DESCRIPTION

P900. P900, Datenblatt Seite 1 DESCRIPTION , Datenblatt Seite 1 Field proven rugged construction High overpressure capability High reliability for demanding environments Application specific customization Excellent media compatibility Shock and

More information

ITF BEACH TENNIS TOUR 2017 TOURNAMENT APPLICATION FORM

ITF BEACH TENNIS TOUR 2017 TOURNAMENT APPLICATION FORM ITF BEACH TENNIS TOUR 2017 TOURNAMENT APPLICATION FORM APPLICATION DEADLINES: (days will be counted from the Monday of the tournament week) Tournaments offering $15,000 prize money or more - 26 weeks (182

More information

Medium pressure two-stage meter regulators for gas flow rates not exceeding 6 m 3 h -1

Medium pressure two-stage meter regulators for gas flow rates not exceeding 6 m 3 h -1 Communication 1790 Medium pressure two-stage meter regulators for gas flow rates not exceeding 6 m 3 h -1 Founded 1863 Royal Charter 1929 Patron: Her Majesty the Queen Communication 1790 Medium pressure

More information

Agilent Dimension Software for ELSD User Manual

Agilent Dimension Software for ELSD User Manual Agilent Dimension Software for ELSD User Manual Agilent Dimension Software for ELSD User Manual Agilent Technologies Notices Agilent Technologies, Inc. 2011 No part of this manual may be reproduced in

More information

SMB Series. SMB Series. Specifications. Interface Dimensions. Available in 50 Ohm and 75 Ohm versions. Snap-on interface reduces installation time.

SMB Series. SMB Series. Specifications. Interface Dimensions. Available in 50 Ohm and 75 Ohm versions. Snap-on interface reduces installation time. Available in 50 Ohm and 75 Ohm versions. Snap-on interface reduces installation time. Self-cleaning outer spring withstands moderate vibration. Small & lightweight. Frequency Range: Up to 4 GHz Specifications

More information

TEL/jlRE" Introduction. Display Features and Modes. Startup Procedure. Power-Up Procedure. Adjustment Modes

TEL/jlRE Introduction. Display Features and Modes. Startup Procedure. Power-Up Procedure. Adjustment Modes TEL/jlRE" Introduction The Telaire 7001 CO 2 /T emperature monitor (shown in Fi gt u e 1 below) is an easy to use hand-held instnunent, which provides stable and highly accurate readings due to Telaire

More information

863 MHz 870 MHz Dipole 2 dbi Antenna for RP SMA

863 MHz 870 MHz Dipole 2 dbi Antenna for RP SMA 863 MHz 870 MHz Dipole 2 dbi Antenna for RP SMA ORDERING INFORMATION Order Number Description 001-0028 868 MHz Dipole Antenna for Reverse Polarity SMA Connector 080-0001 U.FL to SMA Bulkhead Cable, 1.13mm

More information

2014 ADVERTISING OPPORTUNITIES

2014 ADVERTISING OPPORTUNITIES 2014 ADVERTISING OPPORTUNITIES 2014 ADVERTISING OPPORTUNITIES The Calgary Stampede is a volunteer-supported, not-for-profit community organization that preserves and promotes western heritage and values.

More information

SPECIFICATIONS PARTICLE SENSOR KS-18F Higashimotomachi, Kokubunji, Tokyo , Japan

SPECIFICATIONS PARTICLE SENSOR KS-18F Higashimotomachi, Kokubunji, Tokyo , Japan SPECIFICATIONS PARTICLE SENSOR KS-18F 3-20-41 Higashimotomachi, Kokubunji, Tokyo 185-8533, Japan No. 05083-5E 18-01 Printed in Japan Outline The KS-18F is a sensor which uses the light scattering method

More information

Requirements for the certification of movements and mechanical watches resistant to magnetic fields of 1.5 T ( G)

Requirements for the certification of movements and mechanical watches resistant to magnetic fields of 1.5 T ( G) Institut fédéral de métrologie METAS METAS-N001/EN Requirements for the certification of movements and mechanical watches resistant to magnetic fields of 1.5 T (15 000 G) This document is a translation

More information

Coda cx1 Thermal Cycle Test Procedure

Coda cx1 Thermal Cycle Test Procedure Coda cx1 Thermal Cycle Test Procedure CDL 1-TP07-0200:0209 MIT Ref. 85-01050.04 Revision 2.0 8 th June 2004 CDL 1-TP07-0200:0209 Contents 1 Introduction... 1 1.1 Activity Description... 1 2 Requirements...

More information

Product Overview. Product Description CHAPTER

Product Overview. Product Description CHAPTER CHAPTER 1 This chapter provides a functional overview of the Cisco Redundant Power System 2300 and covers these topics: Product Description, page 1-1 Features, page 1-3 Supported Devices, page 1-4 Deployment

More information

DigiTRON Electrical Flying Leads, Jumpers and Harness Assemblies Site Received Test Manual

DigiTRON Electrical Flying Leads, Jumpers and Harness Assemblies Site Received Test Manual 1 Document No: SRT-001 DigiTRON Electrical Flying Leads, Jumpers and Harness Assemblies Site Received Test Manual www.siemens.com/energy/connector-operations-manual 2 This page records the revision status

More information

HOBIE 16 / HOBIE 20 NORTH AMERICAN CHAMPIONSHIPS

HOBIE 16 / HOBIE 20 NORTH AMERICAN CHAMPIONSHIPS HOBIE 16 / HOBIE 20 NORTH AMERICAN CHAMPIONSHIPS Ramada Plaza Beach Resort, Ft. Walton Beach, FL November 6th 11th 2011 Organizing Authority: Hobie Class Association of North America (HCA-NA) SAILING INSTRUCTIONS

More information

CONTROL and INSTRUMENTATION

CONTROL and INSTRUMENTATION CONTROL and INSTRUMENTATION COURSE 500: 5 DAYS: Max 8 Candidates This course covers the key aspects of current instrumentation and process control technology and is designed to enable maintenance personnel

More information

Explosive gas migration monitoring for a sanitary landfill facility.

Explosive gas migration monitoring for a sanitary landfill facility. 3745-27-12 Explosive gas migration monitoring for a sanitary landfill facility. (A) Applicability and implementation. This rule applies to the following: (1) The owner or operator of a sanitary landfill

More information

Features. Description

Features. Description Features Fast response flow meter ideal for inert gas and liquid mass flow measurement applications Smart electronics permit field adjustment of critical flow meter settings Field validation of flow meter

More information

T EK-COR 1100A Coriolis Mass Flowmeter

T EK-COR 1100A Coriolis Mass Flowmeter T EK-COR 1100A Coriolis Mass Flowmeter Instruction Manual Document Number: IM-1100A NOTICE Read this manual before working with the product. For personal and system safety, and for optimum product performance,

More information

! Warning, refer to accompanying documents.

! Warning, refer to accompanying documents. About this Manual To the best of our knowledge and at the time written, the information contained in this document is technically correct and the procedures accurate and adequate to operate this instrument

More information

User s Guide. CO2 & O2 Controller for miniature incubators

User s Guide. CO2 & O2 Controller for miniature incubators CO2 O2 Control User s Guide CO2 & O2 Controller for miniature incubators Precise CO2 & O2 Control throughout the experiment Media ph control Compatible with any perfusion system Miniature incubators for

More information

UNDERSTANDING, ACCELERATED

UNDERSTANDING, ACCELERATED UNDERSTANDING, ACCELERATED MEASURE FLOW, PRESSURE, AND TEMPERATURE ALL IN ONE INSTRUMENT! Designed for Performance TSI thermal mass flowmeters incorporate a proprietary platinum film sensor design for

More information

ANNUAL DYNAMIC POSITIONING TRIALS FOR DYNAMICALLY POSITIONED VESSELS

ANNUAL DYNAMIC POSITIONING TRIALS FOR DYNAMICALLY POSITIONED VESSELS Author s Name Name of the Paper Session DYNAMIC POSITIONING CONFERENCE October 11-12, 2011 OPERATIONS SESSION ANNUAL DYNAMIC POSITIONING TRIALS FOR DYNAMICALLY POSITIONED VESSELS By Ian Giddings The International

More information