Hilti, Inc South 122 nd East Avenue Tulsa, OK

Size: px
Start display at page:

Download "Hilti, Inc South 122 nd East Avenue Tulsa, OK"

Transcription

1 Attached are page(s) from the 2014 Hilti North American Product Tech Guide. For complete details on this product, including data development, product specifications, general suitability, installation, corrosion, and spacing and edge distance guidelines, please refer to the Technical Guide, or contact Hilti. Hilti, Inc South 122 nd East Avenue Tulsa, OK

2 3.2.4 HIT-RE 500-SD Epoxy Adhesive Anchoring System Product Description Material Specifications Technical Data Installation Instructions Ordering Information Listings/Approvals ICC-ES (International Code Council) ESR-2322 NSF/ANSI Std 61 certification for use in potable water European Technical Approval ETA-07/0260, ETA-09/0295 COLA (City of Los Angeles) RR25700 Independent Code Evaluation IBC /IRC 2009 IBC /IRC 2006 IBC /IRC 2003 IBC /IRC 2000 FBC 2007 LEED Credit 4.1-Low Emitting Materials The Leadership in Energy and Environmental Design (LEED ) Green Building Rating system TM is the nationally accepted benchmark for the design, construction and operation of high performance green buildings Product description HIT-RE 500-SD Adhesive Anchoring System is an injectable two-component epoxy adhesive. The two components are kept separate by means of a dualcylinder foil pack attached to a manifold. The two components combine and react when dispensed through a static mixing nozzle attached to the manifold. HIT-RE 500-SD Adhesive Anchoring System may be used with continuously threaded rod, Hilti HIS-N and HIS-RN internally-threaded inserts or deformed reinforcing bar installed in cracked or uncracked concrete. The primary components of the Hilti Adhesive Anchoring System are: HIT-RE 500-SD adhesive packaged in foil packs Adhesive mixing and dispensing equipment Equipment for hole cleaning and adhesive injection Product features Superior bond performance Seismic qualified per IBC /IRC 2009, IBC /IRC 2006, IBC /IRC 2003 and IBC /IRC Please refer to ESR-2322 for Seismic Design Category A through F Use in diamond cored or pneumatic drilled holes Use underwater up to 165 ft (50 m) Meets requirements of ASTM C881-90, Type IV, Grade 2 and 3, Class A, B, C except gel times Meets requirements of AASHTO specification M235, Type IV, Grade 3, Class A, B, C except gel times Mixing tube provides proper mixing, eliminates measuring errors and minimizes waste Contains no styrene and virtually odorless Extended temperature range from 41 F to 104 F (5 C to 40 C) Excellent weathering resistance and resistant to elevated temperature. 102 Hilti, Inc. (US) I en español I Hilti (Canada) Corp I I Anchor Fastening Technical Guide 2014

3 HIT-RE 500-SD Epoxy Adhesive Anchoring System Guide Specifications Master Format Section: Previous 2004 Format Concrete anchors Related Sections: Concrete reinforcing Metal fabrications Structural metal framing Injectable adhesive shall be used for installation of all reinforcing steel dowels or threaded anchor rods and inserts into existing concrete. Adhesive shall be furnished in side-by-side refill packs which keep component A and component B separate. Side-by-side packs shall be designed to compress during use to minimize waste volume. Side-by-side packs shall also be designed to accept static mixing nozzle which thoroughly blends component A and component B and allows injection directly into drilled hole. Only injection tools and static mixing nozzles as recommended by manufacturer shall be used. Manufacturer s instructions shall be followed. Injection adhesive shall be formulated to include resin and hardener to provide optimal curing speed as well as high strength and stiffness. Typical curing time at 68 F (20 C) shall be approximately 12 hours. Injection adhesive shall be HIT RE 500 SD, as furnished by Hilti. Anchor rods shall be end stamped to show the grade of steel and overall rod length. Anchor rods shall be manufactured to meet the following requirements: 1. HAS-E carbon steel 2. ASTM A193, Grade B7 (high strength carbon steel anchor) 3. AISI Type 304 or AISI Type 316 stainless steel meeting the requirements of ASTM F593 (condition CW) Special order length HAS Rods may vary from standard product. Nuts and washers of other grades and styles having specified proof load strength greater than the specified grade and style are also suitable. Nuts must have specified proof load strength equal to or greater than the minimum tensile strength of the specified threaded rod Material specifications Table 1 - Material properties of fully cured HIT-RE 500-SD Bond Strength ASTM C day cure 7 day cure 12.4 MPa 12.4 MPa 1800 psi 1800 psi Compressive Strength ASTM D MPa 12,000 psi Compressive Modulus ASTM D MPa 0.22 x 10 6 psi Tensile Strength 7 day ASTM D MPa 6310 psi Elongation at break ASTM D % 2.0% Heat Deflection Temperature ASTM D C 146 F Absorption ASTM D % 0.06% Linear Coefficient of Shrinkage on Cure ASTM D Electrical resistance DIN IEC 93 (12.93) 6.6 x Ω/m 1.7 x Ω/in Material Specifications for HAS threaded rods are listed in Section Material Specifications for HIS-N Internally Threaded Inserts are listed in Section Technical data The load values contained in this section are Hilti Simplified Design Tables. The load tables in this section were developed using the strength design parameters and variables of ESR-1917 and the equations within ACI Appendix D. For a detailed explanation of the Hilti Simplified Design Tables, refer to Section Data tables from ESR-1917 are not contained in this section, but can be found at or at Hilti, Inc. (US) I en español I Hilti (Canada) Corp I I Anchor Fastening Technical Guide

4 3.2.4 HIT-RE 500-SD Epoxy Adhesive Anchoring System HIT-RE 500-SD with reinforcing steel (rebar) Figure 1 - Rebar installed with HIT-RE 500-SD adhesive Table 2 - Rebar installed HIT-RE 500-SD adhesive Setting information Symbol Units Rebar size Nominal bit diameter d o in. 1/2 5/8 3/4 7/ /8 1-3/8 1-1/2 Standard effective embedment h ef,std in. 3-3/8 4-1/2 5-5/8 6-3/4 7-7/ /8 11-1/4 (mm) (86) (114) (143) (171) (200) (229) (257) (286) Effective embedment minimum h ef,min in. 2-3/8 2-3/4 3-1/8 3-1/2 3-1/ /2 5 (mm) (60) (70) (79) (89) (89) (102) (114) (127) maximum h ef,max in. 7-1/ / / /2 25 (mm) (191) (254) (318) (381) (445) (508) (572) (635) Minimum concrete member thickness h min in. h ef + 1-1/4 (mm) hef + 30 h ef + 2d o 104 Hilti, Inc. (US) I en español I Hilti (Canada) Corp I I Anchor Fastening Technical Guide 2014

5 HIT-RE 500-SD Epoxy Adhesive Anchoring System Table 3 - Hilti HIT-RE 500-SD adhesive design strength (factored resistance) with concrete / bond failure for rebar in uncracked concrete 1,2,3,4,5,6,7,8,9 Tension ϕn n or N r Shear ϕv n or V r Rebar size Effective embedment in. (mm) ƒ c = 2500 psi (17.2 Mpa) ƒ c = 3000 psi (20.7 Mpa) ƒ c = 4000 psi (27.6 Mpa) ƒ c = 6000 psi (41.4 Mpa) ƒ c = 2500 psi (17.2 Mpa) ƒ c = 3000 psi (20.7 Mpa) ƒ c = 4000 psi (27.6 Mpa) ƒ c = 6000 psi (41.4 Mpa) 3-3/8 4,835 5,300 5,855 6,205 10,415 11,410 12,610 13,365 (86) (21.5) (23.6) (26.0) (27.6) (46.3) (50.8) (56.1) (59.5) #3 4-1/2 7,445 7,805 7,805 8,275 16,035 16,810 16,810 17,820 (114) (33.1) (34.7) (34.7) (36.8) (71.3) (74.8) (74.8) (79.3) 7-1/2 13,010 13,010 13,010 13,790 28,020 28,020 28,020 29,700 (191) (57.9) (57.9) (57.9) (61.3) (124.6) (124.6) (124.6) (132.1) 4-1/2 7,445 8,155 9,420 10,885 16,035 17,570 20,285 23,445 (114) (33.1) (36.3) (41.9) (48.4) (71.3) (78.2) (90.2) (104.3) #4 6 11,465 12,560 13,690 14,515 24,690 27,045 29,490 31,260 (152) (51.0) (55.9) (60.9) (64.6) (109.8) (120.3) (131.2) (139.1) 10 22,820 22,820 22,820 24,190 49,150 49,150 49,150 52,100 (254) (101.5) (101.5) (101.5) (107.6) (218.6) (218.6) (218.6) (231.8) 5-5/8 10,405 11,400 13,165 16,120 22,415 24,550 28,350 34,720 (143) (46.3) (50.7) (58.6) (71.7) (99.7) (109.2) (126.1) (154.4) #5 7-1/2 16,020 17,550 20,265 21,765 34,505 37,800 43,650 46,875 (191) (71.3) (78.1) (90.1) (96.8) (153.5) (168.1) (194.2) (208.5) 12-1/2 34,220 34,220 34,220 36,275 73,705 73,705 73,705 78,125 (318) (152.2) (152.2) (152.2) (161.4) (327.9) (327.9) (327.9) (347.5) 6-3/4 13,680 14,985 17,305 21,190 29,460 32,275 37,265 45,645 (171) (60.9) (66.7) (77.0) (94.3) (131.0) (143.6) (165.8) (203.0) #6 9 21,060 23,070 26,640 30,170 45,360 49,690 57,375 64,985 (229) (93.7) (102.6) (118.5) (134.2) (201.8) (221.0) (255.2) (289.1) 15 45,315 47,440 47,440 50,285 97, , , ,305 (381) (201.6) (211.0) (211.0) (223.7) (434.1) (454.5) (454.5) (481.8) 7-7/8 17,235 18,885 21,805 25,240 37,125 40,670 46,960 57,515 (200) (76.7) (84.0) (97.0) (112.3) (165.1) (180.9) (208.9) (255.8) #7 10-1/2 26,540 29,070 31,750 33,655 57,160 62,615 72,300 85,665 (267) (118.1) (129.3) (141.2) (149.7) (254.3) (278.5) (321.6) (381.1) 17-1/2 52,915 52,915 52,915 56, , , , ,780 (445) (235.4) (235.4) (235.4) (249.5) (547.1) (599.2) (599.2) (635.1) 9 21,060 23,070 26,640 32,060 45,360 49,690 57,375 70,270 (229) (93.7) (102.6) (118.5) (142.6) (201.8) (221.0) (255.2) (312.6) # ,425 35,520 40,330 42,750 69,835 76,500 88, ,190 (305) (144.2) (158.0) (179.4) (190.2) (310.6) (340.3) (392.9) (481.3) 20 67,215 67,215 67,215 71, , , , ,355 (508) (299.0) (299.0) (299.0) (316.9) (668.4) (732.2) (761.0) (806.7) 10-1/8 25,130 27,530 31,785 38,930 54,125 59,290 68,465 83,850 (257) (111.8) (122.5) (141.4) (173.2) (240.8) (263.7) (304.5) (373.0) #9 13-1/2 38,690 42,380 48,940 52,850 83,330 91, , ,095 (343) (172.1) (188.5) (217.7) (235.1) (370.7) (406.1) (468.9) (574.2) 22-1/2 83,100 83,100 83,100 88, , , , ,220 (572) (369.6) (369.6) (369.6) (391.8) (797.6) (873.7) (940.9) (997.4) 11-1/4 29,430 32,240 37,230 45,595 63,395 69,445 80,185 98,205 (286) (130.9) (143.4) (165.6) (202.8) (282.0) (308.9) (356.7) (436.8) # ,315 49,640 57,320 63,875 97, , , ,200 (381) (201.6) (220.8) (255.0) (284.1) (434.1) (475.6) (549.2) (672.6) 25 97, , , , , , , ,985 (635) (433.7) (446.8) (446.8) (473.6) (934.1) (1023.3) (1137.2) (1205.4) 1 See Section for explanation on development of load values. 2 See Section to convert design strength (factored resistance) value to ASD value. 3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 4 Apply spacing, edge distance, and concrete thickness factors in Tables 6-21 as necessary. Compare to the steel values in Table 5. The lesser of the values is to be used for the design. 5 Data is for temperature range A: Max. short term temperature = 110 F (43 C), max. long term temperature = 80 F (26 C). For temperature range B: Max. short term temperature = 162 F (72 C), max. long term temperature = 110 F (43 C) multiply above value by Short term elevated concrete temperatures are those that occur over brief intervals, e.g., as a result of diurnal cycling. Long term concrete temperatures are roughly constant over significant periods of time. 6 Tabular values are for dry concrete conditions. For water saturated concrete multiply design strength (factored resistance) by For water-filled drilled holes multiply design strength (factored resistance) by For submerged (under water) applications multiply design strength (factored resistance) by Tabular values are for short term loads only. For sustained loads including overhead use, see Section Tabular values are for normal weight concrete only. For lightweight concrete multiply design strength (factored resistance) by λ a as follows: For sand-lightweight, λ a = For all-lightweight, λ a = Tabular values are for holes drilled in concrete with carbide tipped hammer drill bit. For diamond core drilling multiply above value by Diamond core drilling is not permitted for the water-filled or underwater (submerged) applications Hilti, Inc. (US) I en español I Hilti (Canada) Corp I I Anchor Fastening Technical Guide

6 3.2.4 HIT-RE 500-SD Epoxy Adhesive Anchoring System Table 4 - Hilti HIT-RE 500-SD adhesive design strength (factored resistance) with concrete / bond failure for rebar in cracked concrete 1,2,3,4,5,6,7,8,9,10 Tension ϕn n or N r Shear ϕv n or V r Rebar size Effective embedment in. (mm) ƒ c = 2500 psi (17.2 Mpa) ƒ c = 3000 psi (20.7 Mpa) ƒ c = 4000 psi (27.6 Mpa) ƒ c = 6000 psi (41.4 Mpa) ƒ c = 2500 psi (17.2 Mpa) ƒ c = 3000 psi (20.7 Mpa) ƒ c = 4000 psi (27.6 Mpa) ƒ c = 6000 psi (41.4 Mpa) 3-3/8 2,815 2,815 2,815 2,985 6,065 6,065 6,065 6,430 (86) (12.5) (12.5) (12.5) (13.3) (27.0) (27.0) (27.0) (28.6) #3 4-1/2 3,755 3,755 3,755 3,980 8,090 8,090 8,090 8,575 (114) (16.7) (16.7) (16.7) (17.7) (36.0) (36.0) (36.0) (38.1) 7-1/2 6,260 6,260 6,260 6,635 13,485 13,485 13,485 14,290 (191) (27.8) (27.8) (27.8) (29.5) (60.0) (60.0) (60.0) (63.6) 4-1/2 4,940 4,940 4,940 5,235 10,640 10,640 10,640 11,275 (114) (22.0) (22.0) (22.0) (23.3) (47.3) (47.3) (47.3) (50.2) #4 6 6,585 6,585 6,585 6,980 14,185 14,185 14,185 15,035 (152) (29.3) (29.3) (29.3) (31.0) (63.1) (63.1) (63.1) (66.9) 10 10,975 10,975 10,975 11,635 23,640 23,640 23,640 25,060 (254) (48.8) (48.8) (48.8) (51.8) (105.2) (105.2) (105.2) (111.5) 5-5/8 7,370 7,500 7,500 7,950 15,875 16,160 16,160 17,130 (143) (32.8) (33.4) (33.4) (35.4) (70.6) (71.9) (71.9) (76.2) #5 7-1/2 10,005 10,005 10,005 10,605 21,545 21,545 21,545 22,835 (191) (44.5) (44.5) (44.5) (47.2) (95.8) (95.8) (95.8) (101.6) 12-1/2 16,670 16,670 16,670 17,670 35,905 35,905 35,905 38,060 (318) (74.2) (74.2) (74.2) (78.6) (159.7) (159.7) (159.7) (169.3) 6-3/4 9,690 10,340 10,340 10,960 20,870 22,265 22,265 23,600 (171) (43.1) (46.0) (46.0) (48.8) (92.8) (99.0) (99.0) (105.0) #6 9 13,785 13,785 13,785 14,610 29,690 29,690 29,690 31,470 (229) (61.3) (61.3) (61.3) (65.0) (132.1) (132.1) (132.1) (140.0) 15 22,975 22,975 22,975 24,350 49,480 49,480 49,480 52,450 (381) (102.2) (102.2) (102.2) (108.3) (220.1) (220.1) (220.1) (233.3) 7-7/8 10,895 10,895 10,895 11,550 26,300 27,730 27,730 29,395 (200) (48.5) (48.5) (48.5) (51.4) (117.0) (123.3) (123.3) (130.8) #7 10-1/2 14,525 14,525 14,525 15,395 36,975 36,975 36,975 39,190 (267) (64.6) (64.6) (64.6) (68.5) (164.5) (164.5) (164.5) (174.3) 17-1/2 24,210 24,210 24,210 25,660 61,625 61,625 61,625 65,320 (445) (107.7) (107.7) (107.7) (114.1) (274.1) (274.1) (274.1) (290.6) 9 13,295 13,295 13,295 14,095 32,130 33,845 33,845 35,875 (229) (59.1) (59.1) (59.1) (62.7) (142.9) (150.5) (150.5) (159.6) # ,730 17,730 17,730 18,790 45,125 45,125 45,125 47,835 (305) (78.9) (78.9) (78.9) (83.6) (200.7) (200.7) (200.7) (212.8) 20 29,545 29,545 29,545 31,320 75,210 75,210 75,210 79,720 (508) (131.4) (131.4) (131.4) (139.3) (334.5) (334.5) (334.5) (354.6) 10-1/8 15,745 15,745 15,745 16,690 38,340 40,080 40,080 42,485 (257) (70.0) (70.0) (70.0) (74.2) (170.5) (178.3) (178.3) (189.0) #9 13-1/2 20,995 20,995 20,995 22,255 53,440 53,440 53,440 56,645 (343) (93.4) (93.4) (93.4) (99.0) (237.7) (237.7) (237.7) (252.0) 22-1/2 34,990 34,990 34,990 37,090 89,065 89,065 89,065 94,410 (572) (155.6) (155.6) (155.6) (165.0) (396.2) (396.2) (396.2) (420.0) 11-1/4 17,740 17,740 17,740 18,800 44,905 45,150 45,150 47,860 (286) (78.9) (78.9) (78.9) (83.6) (199.7) (200.8) (200.8) (212.9) # ,650 23,650 23,650 25,070 60,200 60,200 60,200 63,815 (381) (105.2) (105.2) (105.2) (111.5) (267.8) (267.8) (267.8) (283.9) 25 39,415 39,415 39,415 41, , , , ,355 (635) (175.3) (175.3) (175.3) (185.8) (446.3) (446.3) (446.3) (473.1) 1 See Section for explanation on development of load values. 2 See Section to convert design strength (factored resistance) value to ASD value. 3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 4 Apply spacing, edge distance, and concrete thickness factors in Tables 6-21 as necessary. Compare to the steel values in Table 5. The lesser of the values is to be used for the design. 5 Data is for temperature range A: Max. short term temperature = 110 F (43 C), max. long term temperature = 80 F (26 C). For temperature range B: Max. short term temperature = 162 F (72 C), max. long term temperature = 110 F (43 C) multiply above value by Short term elevated concrete temperatures are those that occur over brief intervals, e.g., as a result of diurnal cycling. Long term concrete temperatures are roughly constant over significant periods of time. 6 Tabular values are for dry concrete conditions. For water saturated concrete multiply design strength (factored resistance) by For water-filled drilled holes multiply design strength (factored resistance) by For submerged (under water) applications multiply design strength (factored resistance) by Tabular values are for short term loads only. For sustained loads including overhead use, see Section Tabular values are for normal weight concrete only. For lightweight concrete multiply design strength (factored resistance) by λ a as follows: For sand-lightweight, λ a = For all-lightweight, λ a = Tabular values are for static loads only. For seismic loads, multiply above value by α seis = See section for additional information on seismic applications. 10 Tabular values are for holes drilled in concrete with carbide tipped hammer drill bit. Diamond core drilling is not permitted in cracked concrete conditions. 106 Hilti, Inc. (US) I en español I Hilti (Canada) Corp I I Anchor Fastening Technical Guide 2014

7 HIT-RE 500-SD Epoxy Adhesive Anchoring System Table 5 - Steel design strength (ACI 318 Appendix D Based Design) for rebar 1 ASTM A615 Grade 40 2 ASTM A615 Grade 60 2 ASTM A706 Grade 60 2 Rebar size #3 #4 #5 #6 #7 #8 #9 #10 Tensile 3 ϕn sa Shear 4 ϕv sa Seismic Shear 5 ϕv sa Tensile 3 ϕn sa Shear 4 ϕv sa Seismic Shear 5 ϕv sa Tensile 3 ϕn sa Shear 4 ϕv sa Seismic Shear 5 ϕv sa 4,290 2,375 1,663 6,435 3,565 2,496 6,600 3,430 2,401 (19.1) (10.6) (7.4) (28.6) (15.9) (11.1) (29.4) (15.3) (10.7) 7,800 4,320 3,024 11,700 6,480 4,536 12,000 6,240 4,368 (34.7) (19.2) (13.5) (52.0) (28.8) (20.2) (53.4) (27.8) (19.4) 12,090 6,695 4,687 18,135 10,045 7,032 18,600 9,670 6,769 (53.8) (29.8) (20.8) (80.7) (44.7) (31.3) (82.7) (43.0) (30.1) 17,160 9,505 6,654 25,740 14,255 9,979 26,400 13,730 9,611 (76.3) (42.3) (29.6) (114.5) (63.4) (44.4) (117.4) (61.1) (42.8) 23,400 12,960 9,072 35,100 19,440 13,608 36,000 18,720 13,104 (104.1) (57.6) (40.4) (156.1) (86.5) (60.5) (160.1) (83.3) (58.3) 30,810 17,065 11,946 46,215 25,595 17,917 47,400 24,650 17,255 (137.0) (75.9) (53.1) (205.6) (113.9) (79.7) (210.8) (109.6) (76.8) 39,000 21,600 15,120 58,500 32,400 22,680 60,000 31,200 21,840 (173.5) (96.1) (67.3) (260.2) (144.1) (100.9) (266.9) (138.8) (97.1) 49,530 27,430 19,201 74,295 41,150 28,805 76,200 39,625 27,738 (220.3) (122.0) (85.4) (330.5) (183.0) (128.1) (339.0) (176.3) (123.4) 1 See Section to convert design strength (factored resistance) value to ASD value. 2 ASTM A706 Grade 60 rebar are considered ductile steel elements. ASTM A615 Grade 40 and 60 rebar are considered brittle steel elements. 3 Tensile = A se,n f uta as noted in ACI 318 Appendix D. 4 Shear = 0.60 A se,n f uta as noted in ACI 318 Appendix D 5 Seismic shear values determined by multiplying V sa x α V,seis where α V,seis = 0.7. See Section for additional information on seismic applications Hilti, Inc. (US) I en español I Hilti (Canada) Corp I I Anchor Fastening Technical Guide

8 3.2.4 HIT-RE 500-SD Epoxy Adhesive Anchoring System Table 6 - Load adjustment factors for #3 rebar in uncracked concrete 1,2,3 #3 uncracked concrete Embedment in. 3-3/8 4-1/2 7-1/2 3-3/8 4-1/2 7-1/2 3-3/8 4-1/2 7-1/2 3-3/8 4-1/2 7-1/2 3-3/8 4-1/2 7-1/2 3-3/8 4-1/2 7-1/2 h ef (mm) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) 1-3/4 (44) n/a n/a n/a n/a n/a n/a n/a n/a n/a 1-7/8 (48) n/a n/a n/a 2 (51) n/a n/a n/a 3 (76) n/a n/a n/a 3-5/8 (92) n/a n/a n/a 4 (102) n/a n/a n/a 4-5/8 (117) n/a n/a 5 (127) n/a n/a 5-3/4 (146) n/a 6 (152) n/a 7 (178) n/a 8 (203) n/a 8-3/4 (222) (229) (254) (279) (305) (356) (406) (457) (610) (762) (914) >48 (1219) Table 7 - Load adjustment factors for #3 rebar in cracked concrete 1,2,3 #3 cracked concrete Embedment in. 3-3/8 4-1/2 7-1/2 3-3/8 4-1/2 7-1/2 3-3/8 4-1/2 7-1/2 3-3/8 4-1/2 7-1/2 3-3/8 4-1/2 7-1/2 3-3/8 4-1/2 7-1/2 h ef (mm) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) 1-3/4 (44) n/a n/a n/a n/a n/a n/a n/a n/a n/a 1-7/8 (48) n/a n/a n/a 2 (51) n/a n/a n/a 3 (76) n/a n/a n/a 3-5/8 (92) n/a n/a n/a 4 (102) n/a n/a n/a 4-5/8 (117) n/a n/a 5 (127) n/a n/a 5-3/4 (146) n/a 6 (152) n/a 7 (178) n/a 8 (203) n/a 8-3/4 (222) (229) (254) (279) (305) (356) (406) (457) (610) (762) (914) >48 (1219) Linear interpolation not permitted. 2 Shaded area with reduced edge distance is permitted provided the installation torque is reduced to 0.30 T max for 5d < s < 16-in. and to 0.5 T max for s > 16-in. 3 When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with a thin concrete member) the design can become very conservative. To optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using the design equations from ACI 318 Appendix D. 4 reduction in shear,, assumes an influence of a nearby edge. If no edge exists, then =. 5 reduction factor in shear,, assumes an influence of a nearby edge. If no edge exists, then = Hilti, Inc. (US) I en español I Hilti (Canada) Corp I I Anchor Fastening Technical Guide 2014

9 HIT-RE 500-SD Epoxy Adhesive Anchoring System Table 8 - Load adjustment factors for #4 rebar in uncracked concrete 1,2,3 #4 uncracked concrete Embedment in. 3-3/8 4-1/2 7-1/2 3-3/8 4-1/2 7-1/2 3-3/8 4-1/2 7-1/2 3-3/8 4-1/2 7-1/2 3-3/8 4-1/2 7-1/2 3-3/8 4-1/2 7-1/2 h ef (mm) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) 1-3/4 (44) n/a n/a n/a n/a n/a n/a n/a n/a n/a 2-1/2 (64) n/a n/a n/a 3 (76) n/a n/a n/a 4 (102) n/a n/a n/a 5 (127) n/a n/a n/a 5-3/4 (146) n/a n/a 6 (152) n/a n/a 7 (178) n/a n/a 7-1/4 (184) n/a 8 (203) n/a 9 (229) n/a 10 (254) n/a 11-1/4 (286) (305) (356) (406) (457) (508) (559) (610) (762) (914) > 48 (1219) Table 9 - Load adjustment factors for #4 rebar in cracked concrete 1,2,3 #4 cracked concrete Embedment in. 3-3/8 4-1/2 7-1/2 3-3/8 4-1/2 7-1/2 3-3/8 4-1/2 7-1/2 3-3/8 4-1/2 7-1/2 3-3/8 4-1/2 7-1/2 3-3/8 4-1/2 7-1/2 h ef (mm) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) 1-3/4 (44) n/a n/a n/a n/a n/a n/a n/a n/a n/a 2-1/2 (64) n/a n/a n/a 3 (76) n/a n/a n/a 4 (102) n/a n/a n/a 5 (127) n/a n/a n/a 5-3/4 (146) n/a n/a 6 (152) n/a n/a 7 (178) n/a n/a 7-1/4 (184) n/a 8 (203) n/a 9 (229) n/a 10 (254) n/a 11-1/4 (286) (305) (356) (406) (457) (508) (559) (610) (762) (914) > 48 (1219) Linear interpolation not permitted. 2 Shaded area with reduced edge distance is permitted provided the installation torque is reduced to 0.30 T max for 5d < s < 16-in. and to 0.5 T max for s > 16-in. 3 When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with a thin concrete member) the design can become very conservative. To optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using the design equations from ACI 318 Appendix D. 4 reduction in shear,, assumes an influence of a nearby edge. If no edge exists, then =. 5 reduction factor in shear,, assumes an influence of a nearby edge. If no edge exists, then = Hilti, Inc. (US) I en español I Hilti (Canada) Corp I I Anchor Fastening Technical Guide

10 3.2.4 HIT-RE 500-SD Epoxy Adhesive Anchoring System Table 10 - Load adjustment factors for #5 rebar in uncracked concrete 1,2,3 #5 uncracked concrete Embedment in. 5-5/8 7-1/2 12-1/2 5-5/8 7-1/2 12-1/2 5-5/8 7-1/2 12-1/2 5-5/8 7-1/2 12-1/2 5-5/8 7-1/2 12-1/2 5-5/8 7-1/2 12-1/2 h ef (mm) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) 1-3/4 (44) n/a n/a n/a n/a n/a n/a n/a n/a n/a 3-1/8 (79) n/a n/a n/a 4 (102) n/a n/a n/a 4-5/8 (117) n/a n/a n/a 5 (127) n/a n/a n/a 6 (152) n/a n/a n/a 7 (178) n/a n/a n/a 7-1/8 (181) n/a n/a 8 (203) n/a n/a 9 (229) n/a 10 (254) n/a 11 (279) n/a 12 (305) n/a 14 (356) (406) (457) (508) (559) (610) (660) (711) (762) (914) > 48 (1219) Table 11 - Load adjustment factors for #5 rebar in cracked concrete 1,2,3 #5 cracked concrete Embedment in. 5-5/8 7-1/2 12-1/2 5-5/8 7-1/2 12-1/2 5-5/8 7-1/2 12-1/2 5-5/8 7-1/2 12-1/2 5-5/8 7-1/2 12-1/2 5-5/8 7-1/2 12-1/2 h ef (mm) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) 1-3/4 (44) n/a n/a n/a n/a n/a n/a n/a n/a n/a 3-1/8 (79) n/a n/a n/a 4 (102) n/a n/a n/a 4-5/8 (117) n/a n/a n/a 5 (127) n/a n/a n/a 6 (152) n/a n/a n/a 7 (178) n/a n/a n/a 7-1/8 (181) n/a n/a 8 (203) n/a n/a 9 (229) n/a 10 (254) n/a 11 (279) n/a 12 (305) n/a 14 (356) (406) (457) (508) (559) (610) (660) (711) (762) (914) > 48 (1219) Linear interpolation not permitted. 2 Shaded area with reduced edge distance is permitted provided the installation torque is reduced to 0.30 T max for 5d < s < 16-in. and to 0.5 T max for s > 16-in. 3 When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with a thin concrete member) the design can become very conservative. To optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using the design equations from ACI 318 Appendix D. 4 reduction in shear,, assumes an influence of a nearby edge. If no edge exists, then =. 5 reduction factor in shear,, assumes an influence of a nearby edge. If no edge exists, then = Hilti, Inc. (US) I en español I Hilti (Canada) Corp I I Anchor Fastening Technical Guide 2014

11 HIT-RE 500-SD Epoxy Adhesive Anchoring System Table 12 - Load adjustment factors for #6 rebar in uncracked concrete 1,2,3 #6 uncracked concrete Embedment in. 6-3/ / / / / / h ef (mm) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) 1-3/4 (44) n/a n/a n/a n/a n/a n/a n/a n/a n/a 3-3/4 (95) n/a n/a n/a 4 (102) n/a n/a n/a 5 (127) n/a n/a n/a 5-1/4 (133) n/a n/a n/a 6 (152) n/a n/a n/a 7 (178) n/a n/a n/a 8 (203) n/a n/a n/a 8-1/2 (216) n/a n/a 9 (229) n/a n/a 10 (254) n/a n/a 10-3/4 (273) n/a 12 (305) n/a 14 (356) n/a 16 (406) n/a 16-3/4 (425) (457) (508) (559) (610) (660) (711) (762) (914) > 48 (1219) Table 13 - Load adjustment factors for #6 rebar in cracked concrete 1,2,3 #6 cracked concrete Embedment in. 6-3/ / / / / / h ef (mm) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) 1-3/4 (44) n/a n/a n/a n/a n/a n/a n/a n/a n/a 3-3/4 (95) n/a n/a n/a 4 (102) n/a n/a n/a 5 (127) n/a n/a n/a 5-1/4 (133) n/a n/a n/a 6 (152) n/a n/a n/a 7 (178) n/a n/a n/a 8 (203) n/a n/a n/a 8-1/2 (216) n/a n/a 9 (229) n/a n/a 10 (254) n/a n/a 10-3/4 (273) n/a 12 (305) n/a 14 (356) n/a 16 (406) n/a 16-3/4 (425) (457) (508) (559) (610) (660) (711) (762) (914) > 48 (1219) Linear interpolation not permitted. 2 Shaded area with reduced edge distance is permitted provided the installation torque is reduced to 0.30 T max for 5d < s < 16-in. and to 0.5 T max for s > 16-in. 3 When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with a thin concrete member) the design can become very conservative. To optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using the design equations from ACI 318 Appendix D. 4 reduction in shear,, assumes an influence of a nearby edge. If no edge exists, then =. 5 reduction factor in shear,, assumes an influence of a nearby edge. If no edge exists, then = Hilti, Inc. (US) I en español I Hilti (Canada) Corp I I Anchor Fastening Technical Guide

12 3.2.4 HIT-RE 500-SD Epoxy Adhesive Anchoring System Table 14 - Load adjustment factors for #7 Rebar in uncracked concrete 1,2,3 #7 uncracked concrete Embedment in. 7-7/8 10-1/2 17-1/2 7-7/8 10-1/2 17-1/2 7-7/8 10-1/2 17-1/2 7-7/8 10-1/2 17-1/2 7-7/8 10-1/2 17-1/2 7-7/8 10-1/2 17-1/2 h ef (mm) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) 1-3/4 (44) n/a n/a n/a n/a n/a n/a n/a n/a n/a 4-3/8 (111) n/a n/a n/a 5 (127) n/a n/a n/a 5-1/2 (140) n/a n/a n/a 6 (152) n/a n/a n/a 7 (178) n/a n/a n/a 8 (203) n/a n/a n/a 9 (229) n/a n/a n/a 9-7/8 (251) n/a n/a 10 (254) n/a n/a 11 (279) n/a n/a 12 (305) n/a n/a 12-1/2 (318) n/a 14 (356) n/a 16 (406) n/a 18 (457) n/a 19-1/2 (495) (508) (559) (610) (660) (711) (762) (914) > 48 (1219) Table 15 - Load adjustment factors for #7 rebar in cracked concrete 1,2,3 #7 cracked concrete Embedment in. 7-7/8 10-1/2 17-1/2 7-7/8 10-1/2 17-1/2 7-7/8 10-1/2 17-1/2 7-7/8 10-1/2 17-1/2 7-7/8 10-1/2 17-1/2 7-7/8 10-1/2 17-1/2 h ef (mm) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) 1-3/4 (44) n/a n/a n/a n/a n/a n/a n/a n/a n/a 4-3/8 (111) n/a n/a n/a 5 (127) n/a n/a n/a 5-1/2 (140) n/a n/a n/a 6 (152) n/a n/a n/a 7 (178) n/a n/a n/a 8 (203) n/a n/a n/a 9 (229) n/a n/a n/a 9-7/8 (251) n/a n/a 10 (254) n/a n/a 11 (279) n/a n/a 12 (305) n/a n/a 12-1/2 (318) n/a 14 (356) n/a 16 (406) n/a 18 (457) n/a 19-1/2 (495) (508) (559) (610) (660) (711) (762) (914) > 48 (1219) Linear interpolation not permitted. 2 Shaded area with reduced edge distance is permitted provided the installation torque is reduced to 0.30 T max for 5d < s < 16-in. and to 0.5 T max for s > 16-in. 3 When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with a thin concrete member) the design can become very conservative. To optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using the design equations from ACI 318 Appendix D. 4 reduction in shear,, assumes an influence of a nearby edge. If no edge exists, then =. 5 reduction factor in shear,, assumes an influence of a nearby edge. If no edge exists, then = Hilti, Inc. (US) I en español I Hilti (Canada) Corp I I Anchor Fastening Technical Guide 2014

13 HIT-RE 500-SD Epoxy Adhesive Anchoring System Table 16 - Load adjustment factors for #8 rebar in uncracked concrete 1,2,3 #8 uncracked concrete Embedment in h ef (mm) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) 1-3/4 (44) n/a n/a n/a n/a n/a n/a n/a n/a n/a 5 (127) n/a n/a n/a 6 (152) n/a n/a n/a 6-1/4 (159) n/a n/a n/a 7 (178) n/a n/a n/a 8 (203) n/a n/a n/a 9 (229) n/a n/a n/a 10 (254) n/a n/a n/a 11 (279) n/a n/a n/a 11-1/4 (286) n/a n/a 12 (305) n/a n/a 13 (330) n/a n/a 14 (356) n/a n/a 14-1/4 (362) n/a 16 (406) n/a 18 (457) n/a 20 (508) n/a 22 (559) n/a 22-1/4 (565) (610) (660) (711) (762) (914) > 48 (1219) Table 17 - Load adjustment factors for #8 rebar in cracked concrete 1,2,3 #8 cracked concrete Embedment in h ef (mm) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) 1-3/4 (44) n/a n/a n/a n/a n/a n/a n/a n/a n/a 5 (127) n/a n/a n/a 6 (152) n/a n/a n/a 6-1/4 (159) n/a n/a n/a 7 (178) n/a n/a n/a 8 (203) n/a n/a n/a 9 (229) n/a n/a n/a 10 (254) n/a n/a n/a 11 (279) n/a n/a n/a 11-1/4 (286) n/a n/a 12 (305) n/a n/a 13 (330) n/a n/a 14 (356) n/a n/a 14-1/4 (362) n/a 16 (406) n/a 18 (457) n/a 20 (508) n/a 22 (559) n/a 22-1/4 (565) (610) (660) (711) (762) (914) > 48 (1219) Linear interpolation not permitted. 2 Shaded area with reduced edge distance is permitted provided the installation torque is reduced to 0.30 T max for 5d < s < 16-in. and to 0.5 T max for s > 16-in. 3 When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with a thin concrete member) the design can become very conservative. To optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using the design equations from ACI 318 Appendix D. 4 reduction in shear,, assumes an influence of a nearby edge. If no edge exists, then =. 5 reduction factor in shear,, assumes an influence of a nearby edge. If no edge exists, then = Hilti, Inc. (US) I en español I Hilti (Canada) Corp I I Anchor Fastening Technical Guide

14 3.2.4 HIT-RE 500-SD Epoxy Adhesive Anchoring System Table 18 - Load adjustment factors for #9 rebar in uncracked concrete 1,2,3 #9 uncracked concrete Embedment in. 10-1/8 13-1/2 22-1/2 10-1/8 13-1/2 22-1/2 10-1/8 13-1/2 22-1/2 10-1/8 13-1/2 22-1/2 10-1/8 13-1/2 22-1/2 10-1/8 13-1/2 22-1/2 h ef (mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) 1-3/4 (44) n/a n/a n/a n/a n/a n/a n/a n/a n/a 5-5/8 (143) n/a n/a n/a 6 (152) n/a n/a n/a 7 (178) n/a n/a n/a 7-1/4 (184) n/a n/a n/a 8 (203) n/a n/a n/a 9 (229) n/a n/a n/a 10 (254) n/a n/a n/a 11 (279) n/a n/a n/a 12 (305) n/a n/a n/a 12-7/8 (327) n/a n/a 13 (330) n/a n/a 14 (356) n/a n/a 16 (406) n/a n/a 16-1/4 (413) n/a 18 (457) n/a 20 (508) n/a 22 (559) n/a 24 (610) n/a 25-1/4 (641) (660) (711) (762) (914) > 48 (1219) Table 19 - Load adjustment factors for #9 rebar in cracked concrete 1,2,3 #9 cracked concrete Embedment in. 10-1/8 13-1/2 22-1/2 10-1/8 13-1/2 22-1/2 10-1/8 13-1/2 22-1/2 10-1/8 13-1/2 22-1/2 10-1/8 13-1/2 22-1/2 10-1/8 13-1/2 22-1/2 h ef (mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) 1-3/4 (44) n/a n/a n/a n/a n/a n/a n/a n/a n/a 5-5/8 (143) n/a n/a n/a 6 (152) n/a n/a n/a 7 (178) n/a n/a n/a 7-1/4 (184) n/a n/a n/a 8 (203) n/a n/a n/a 9 (229) n/a n/a n/a 10 (254) n/a n/a n/a 11 (279) n/a n/a n/a 12 (305) n/a n/a n/a 12-7/8 (327) n/a n/a 13 (330) n/a n/a 14 (356) n/a n/a 16 (406) n/a n/a 16-1/4 (413) n/a 18 (457) n/a 20 (508) n/a 22 (559) n/a 24 (610) n/a 25-1/4 (641) (660) (711) (762) (914) > 48 (1219) Linear interpolation not permitted. 2 Shaded area with reduced edge distance is permitted provided the installation torque is reduced to 0.30 T max for 5d < s < 16-in. and to 0.5 T max for s > 16-in. 3 When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with a thin concrete member) the design can become very conservative. To optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using the design equations from ACI 318 Appendix D. 4 reduction in shear,, assumes an influence of a nearby edge. If no edge exists, then =. 5 reduction factor in shear,, assumes an influence of a nearby edge. If no edge exists, then = Hilti, Inc. (US) I en español I Hilti (Canada) Corp I I Anchor Fastening Technical Guide 2014

15 HIT-RE 500-SD Epoxy Adhesive Anchoring System Table 20 - Load adjustment factors for #10 rebar in uncracked concrete 1,2,3 #10 uncracked concrete Embedment in. 11-1/ / / / / / h ef (mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) 1-3/4 (44) n/a n/a n/a n/a n/a n/a n/a n/a n/a 6-1/4 (159) n/a n/a n/a 7 (178) n/a n/a n/a 8 (203) n/a n/a n/a 9 (229) n/a n/a n/a 10 (254) n/a n/a n/a 11 (279) n/a n/a n/a 12 (305) n/a n/a n/a 13 (330) n/a n/a n/a 14 (356) n/a n/a n/a 14-1/4 (362) n/a n/a 15 (381) n/a n/a 16 (406) n/a n/a 17 (432) n/a n/a 18 (457) n/a 20 (508) n/a 22 (559) n/a 24 (610) n/a 26 (660) n/a 28 (711) (762) (914) > 48 (1219) Table 21 - Load adjustment factors for #10 rebar in cracked concrete 1,2,3 #10 cracked concrete Embedment in. 11-1/ / / / / / h ef (mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) 1-3/4 (44) n/a n/a n/a n/a n/a n/a n/a n/a n/a 6-1/4 (159) n/a n/a n/a 7 (178) n/a n/a n/a 8 (203) n/a n/a n/a 9 (229) n/a n/a n/a 10 (254) n/a n/a n/a 11 (279) n/a n/a n/a 12 (305) n/a n/a n/a 13 (330) n/a n/a n/a 14 (356) n/a n/a n/a 14-1/4 (362) n/a n/a 15 (381) n/a n/a 16 (406) n/a n/a 17 (432) n/a n/a 18 (457) n/a 20 (508) n/a 22 (559) n/a 24 (610) n/a 26 (660) n/a 28 (711) (762) (914) > 48 (1219) Linear interpolation not permitted. 2 Shaded area with reduced edge distance is permitted provided the installation torque is reduced to 0.30 T max for 5d < s < 16-in. and to 0.5 T max for s > 16-in. 3 When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with a thin concrete member) the design can become very conservative. To optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using the design equations from ACI 318 Appendix D. 4 reduction in shear,, assumes an influence of a nearby edge. If no edge exists, then =. 5 reduction factor in shear,, assumes an influence of a nearby edge. If no edge exists, then = Hilti, Inc. (US) I en español I Hilti (Canada) Corp I I Anchor Fastening Technical Guide

16 3.2.4 HIT-RE 500-SD Epoxy Adhesive Anchoring System HIT-RE 500-SD Adhesive with Hilti HAS threaded rods Table 22 - HAS carbon steel threaded rod specifications Setting information Symbol Units Nominal rod diameter 3/8 1/2 5/8 3/4 7/ /4 Nominal bit diameter d o in. 7/16 9/16 3/4 7/ /8 1-3/8 Figure 10 - HAS threaded rods Standard effective embedment h ef,std in. 3-3/8 4-1/2 5-5/8 6-3/4 7-7/ /4 (mm) (86) (114) (143) (171) (200) (229) (286) Effective embedment Fixture hole diameter Fixture hole diameter minimum h ef,min in. 2-3/8 2-3/4 3-1/8 3-1/2 3-1/2 4 5 (mm) (60) (70) (79) (89) (89) (102) (127) maximum h ef,max in. 7-1/ / / (mm) (191) (254) (318) (381) (445) (508) (635) through-set in. 1/2 5/8 13/ / / / /2 1 preset in. 7/16 9/16 11/16 13/16 15/16 1-1/8 1-3/8 ft-lb Installation torque T inst (Nm) (20) (40) (80) (136) (169) (203) (271) 1 Install using (2) washers. See Figure 11. Figure 11 - Installation with (2) washers HAS carbon steel threaded rod specifications Carbon steel rods conform to ISO 898 class 5.8 with a minimum tensile strength of 72.5 ksi (500 MPa) and a minimum yield strength of 58 ksi (400 MPa). HAS-E nuts conform to SAE J995 Grade 5 HAS-E washers conform to ASTM F884, HV, and ANSI B Type A Plain. HAS-E rod, nut and washer has an electroplated zinc coating conforming to ASTM B633, SC 1 HAS Super high strength threaded rod specifications Carbon steel rods manufactured from ASTM A193, Grade B7, with a minimum tensile strength of 125 ksi (862 MPa) and a minimum yield strength of 105 ksi (724 MPa). HAS Super nuts conform to SAE J995 Grade 5 HAS Super washers conform to ASTM F884, HV, and ANSI B Type A Plain. HAS Super rods, nuts and washers, except the 7/8-in. diameter, have an electroplated zinc coating conforming to ASTM B633, SC1 7/8-in. HAS Super rods, nuts and washers are hot-dip galvanized in accordance with ASTM A153 HAS-R 304 stainless steel 3/8-, 1/2- and 5/8-in. rods manufactured from AISI Type 304 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa). 3/4-, 1- and 1 1/4-in. rods are manufactured from AISI Type 304 stainless steel conforming to ASTM F593 Condition CW or cold worked. AISI Type 304 stainless steel nuts conform to ASTM F594 AISI Type 304 stainless steel washers conform to ASTM A240 and ANSI B Type A Plain. HAS-R 316 stainless steel 3/8-, 1/2- and 5/8-in. rods manufactured from AISI Type 316 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa). 3/4-, 1- and 1 1/4-in. rods are manufactured from AISI Type 316 stainless steel conforming to ASTM F593 Condition CW. AISI Type 316 stainless steel nuts conform to ASTM F594 AISI Type 316 stainless steel washers conform to ASTM A240 and ANSI B Type A Plain. 116 Hilti, Inc. (US) I en español I Hilti (Canada) Corp I I Anchor Fastening Technical Guide 2014

17 HIT-RE 500-SD Epoxy Adhesive Anchoring System Table 23 - Hilti HIT-RE 500-SD adhesive design strength (factored resistance) with concrete / bond failure for Hilti HAS threaded rod in uncracked concrete 1,2,3,4,5,6,7,8,9 Nominal anchor diameter in. Effective embedment in. (mm) ƒ c = 2500 psi (17.2 Mpa) Tension ФN n or N r ƒ c = 3000 psi (20.7 Mpa) ƒ c = 4000 psi (27.6 Mpa) ƒ c = 6000 psi (41.4 Mpa) ƒ c = 2500 psi (17.2 Mpa) Shear ФV n or V r ƒ c = 3000 psi (20.7 Mpa) ƒ c = 4000 psi (27.6 Mpa) ƒ c = 6000 psi (41.4 Mpa) 2-3/8 2,855 3,125 3,610 4,405 3,075 3,370 3,890 4,745 (60) (12.7) (13.9) (16.1) (19.6) (13.7) (15.0) (17.3) (21.1) 3-3/8 4,835 5,300 5,905 6,260 10,415 11,410 12,720 13,485 3/8 (86) (21.5) (23.6) (26.3) (27.8) (46.3) (50.8) (56.6) (60.0) 4-1/2 7,445 7,875 7,875 8,345 16,035 16,960 16,960 17,975 (114) (33.1) (35.0) (35.0) (37.1) (71.3) (75.4) (75.4) (80.0) 7-1/2 13,125 13,125 13,125 13,910 28,265 28,265 28,265 29,960 (191) (58.4) (58.4) (58.4) (61.9) (125.7) (125.7) (125.7) (133.3) 2-3/4 3,555 3,895 4,500 5,510 7,660 8,395 9,690 11,870 (70) (15.8) (17.3) (20.0) (24.5) (34.1) (37.3) (43.1) (52.8) 4-1/2 7,445 8,155 9,420 10,885 16,035 17,570 20,285 23,445 1/2 (114) (33.1) (36.3) (41.9) (48.4) (71.3) (78.2) (90.2) (104.3) 6 11,465 12,560 13,690 14,515 24,690 27,045 29,490 31,260 (152) (51.0) (55.9) (60.9) (64.6) (109.8) (120.3) (131.2) (139.1) 10 22,820 22,820 22,820 24,190 49,150 49,150 49,150 52,100 (254) (101.5) (101.5) (101.5) (107.6) (218.6) (218.6) (218.6) (231.8) 3-1/8 4,310 4,720 5,450 6,675 9,280 10,165 11,740 14,380 (79) (19.2) (21.0) (24.2) (29.7) (41.3) (45.2) (52.2) (64.0) 5-5/8 10,405 11,400 13,165 16,120 22,415 24,550 28,350 34,720 5/8 (143) (46.3) (50.7) (58.6) (71.7) (99.7) (109.2) (126.1) (154.4) 7-1/2 16,020 17,550 20,265 21,715 34,505 37,800 43,650 46,765 (191) (71.3) (78.1) (90.1) (96.6) (153.5) (168.1) (194.2) (208.0) 12-1/2 34,140 34,140 34,140 36,190 73,535 73,535 73,535 77,945 (318) (151.9) (151.9) (151.9) (161.0) (327.1) (327.1) (327.1) (346.7) 3-1/2 5,105 5,595 6,460 7,910 11,000 12,050 13,915 17,040 (89) (22.7) (24.9) (28.7) (35.2) (48.9) (53.6) (61.9) (75.8) 6-3/4 13,680 14,985 17,305 21,190 29,460 32,275 37,265 45,645 3/4 (171) (60.9) (66.7) (77.0) (94.3) (131.0) (143.6) (165.8) (203.0) 9 21,060 23,070 26,640 30,170 45,360 49,690 57,375 64,985 (229) (93.7) (102.6) (118.5) (134.2) (201.8) (221.0) (255.2) (289.1) 15 45,315 47,440 47,440 50,285 97, , , ,305 (381) (201.6) (211.0) (211.0) (223.7) (434.1) (454.5) (454.5) (481.8) 3-1/2 5,105 5,595 6,460 7,910 11,000 12,050 13,915 17,040 (89) (22.7) (24.9) (28.7) (35.2) (48.9) (53.6) (61.9) (75.8) 7-7/8 17,235 18,885 21,805 25,240 37,125 40,670 46,960 57,515 7/8 (200) (76.7) (84.0) (97.0) (112.3) (165.1) (180.9) (208.9) (255.8) 10-1/2 26,540 29,070 31,750 33,655 57,160 62,615 72,300 85,665 (267) (118.1) (129.3) (141.2) (149.7) (254.3) (278.5) (321.6) (381.1) 17-1/2 52,915 52,915 52,915 56, , , , ,780 (445) (235.4) (235.4) (235.4) (249.5) (547.1) (599.2) (599.2) (635.1) 4 6,240 6,835 7,895 9,665 13,440 14,725 17,000 20,820 (102) (27.8) (30.4) (35.1) (43.0) (59.8) (65.5) (75.6) (92.6) 9 21,060 23,070 26,640 32,060 45,360 49,690 57,375 70,270 1 (229) (93.7) (102.6) (118.5) (142.6) (201.8) (221.0) (255.2) (312.6) 12 32,425 35,520 40,330 42,750 69,835 76,500 88, ,190 (305) (144.2) (158.0) (179.4) (190.2) (310.6) (340.3) (392.9) (481.3) 20 67,215 67,215 67,215 71, , , , ,355 (508) (299.0) (299.0) (299.0) (316.9) (668.4) (732.2) (761.0) (806.7) 5 8,720 9,555 11,030 13,510 18,785 20,575 23,760 29,100 (127) (38.8) (42.5) (49.1) (60.1) (83.6) (91.5) (105.7) (129.4) 11-1/4 29,430 32,240 37,230 45,595 63,395 69,445 80,185 98, /4 (286) (130.9) (143.4) (165.6) (202.8) (282.0) (308.9) (356.7) (436.8) 15 45,315 49,640 57,320 63,875 97, , , ,200 (381) (201.6) (220.8) (255.0) (284.1) (434.1) (475.6) (549.2) (672.6) 25 97, , , , , , , ,985 (635) (433.7) (446.8) (446.8) (473.6) (934.1) (1023.3) (1137.2) (1205.4) 1 See Section for explanation on development of load values. 2 See Section to convert design strength (factored resistance) value to ASD value. 3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 4 Apply spacing, edge distance, and concrete thickness factors in Tables as necessary. Compare to the steel values in Table 25. The lesser of the values is to be used for the design. 5 Data is for temperature range A: Max. short term temperature = 110 F (43 C), max. long term temperature = 80 F (26 C). For temperature range B: Max. short term temperature = 162 F (72 C), max. long term temperature = 110 F (43 C) multiply above value by Short term elevated concrete temperatures are those that occur over brief intervals, e.g., as a result of diurnal cycling. Long term concrete temperatures are roughly constant over significant periods of time. 6 Tabular values are for dry concrete conditions. For water saturated concrete multiply design strength (factored resistance) by For water-filled drilled holes multiply design strength (factored resistance) by For submerged (under water) applications multiply design strength (factored resistance) by Tabular values are for short term loads only. For sustained loads including overhead use, see Section Tabular values are for normal weight concrete only. For lightweight concrete multiply design strength (factored resistance) by λ a as follows: For sand-lightweight, λ a = For all-lightweight, λ a = Tabular values are for holes drilled in concrete with carbide tipped hammer drill bit. For diamond core drilling multiply above value by Diamond core drilling is not permitted for water-filled or underwater (submerged) applications Hilti, Inc. (US) I en español I Hilti (Canada) Corp I I Anchor Fastening Technical Guide

18 3.2.4 HIT-RE 500-SD Epoxy Adhesive Anchoring System Table 24 - Hilti HIT-RE 500-SD adhesive design strength (factored resistance) with concrete / bond failure for Hilti HAS threaded rod in cracked concrete 1,2,3,4,5,6,7,8,9,10 Nominal anchor diameter in. Effective embedment depth in. (mm) ƒ c = 2500 psi (17.2 Mpa) Tension ФN n or N r ƒ c = 3000 psi (20.7 Mpa) ƒ c = 4000 psi (27.6 Mpa) ƒ c = 6000 psi (41.4 Mpa) ƒ c = 2500 psi (17.2 Mpa) Shear ФV n or V r ƒ c = 3000 psi (20.7 Mpa) ƒ c = 4000 psi (27.6 Mpa) ƒ c = 6000 psi (41.4 Mpa) 2-3/8 1,980 1,980 1,980 2,100 2,135 2,135 2,135 2,265 (60) (8.8) (8.8) (8.8) (9.3) (9.5) (9.5) (9.5) (10.1) 3-3/8 2,815 2,815 2,815 2,985 6,065 6,065 6,065 6,430 3/8 (86) (12.5) (12.5) (12.5) (13.3) (27.0) (27.0) (27.0) (28.6) 4-1/2 3,755 3,755 3,755 3,980 8,090 8,090 8,090 8,575 (114) (16.7) (16.7) (16.7) (17.7) (36.0) (36.0) (36.0) (38.1) 7-1/2 6,260 6,260 6,260 6,635 13,485 13,485 13,485 14,290 (191) (27.8) (27.8) (27.8) (29.5) (60.0) (60.0) (60.0) (63.6) 2-3/4 2,520 2,760 3,020 3,200 5,425 5,945 6,500 6,890 (70) (11.2) (12.3) (13.4) (14.2) (24.1) (26.4) (28.9) (30.6) 4-1/2 4,940 4,940 4,940 5,235 10,640 10,640 10,640 11,275 1/2 (114) (22.0) (22.0) (22.0) (23.3) (47.3) (47.3) (47.3) (50.2) 6 6,585 6,585 6,585 6,980 14,185 14,185 14,185 15,035 (152) (29.3) (29.3) (29.3) (31.0) (63.1) (63.1) (63.1) (66.9) 10 10,975 10,975 10,975 11,635 23,640 23,640 23,640 25,060 (254) (48.8) (48.8) (48.8) (51.8) (105.2) (105.2) (105.2) (111.5) 3-1/8 3,050 3,345 3,860 4,420 6,575 7,200 8,315 9,515 (79) (13.6) (14.9) (17.2) (19.7) (29.2) (32.0) (37.0) (42.3) 5-5/8 7,370 7,500 7,500 7,950 15,875 16,160 16,160 17,130 5/8 (143) (32.8) (33.4) (33.4) (35.4) (70.6) (71.9) (71.9) (76.2) 7-1/2 10,005 10,005 10,005 10,605 21,545 21,545 21,545 22,835 (191) (44.5) (44.5) (44.5) (47.2) (95.8) (95.8) (95.8) (101.6) 12-1/2 16,670 16,670 16,670 17,670 35,905 35,905 35,905 38,060 (318) (74.2) (74.2) (74.2) (78.6) (159.7) (159.7) (159.7) (169.3) 3-1/2 3,620 3,965 4,575 5,605 7,790 8,535 9,855 12,070 (89) (16.1) (17.6) (20.4) (24.9) (34.7) (38.0) (43.8) (53.7) 6-3/4 9,690 10,340 10,340 10,960 20,870 22,265 22,265 23,600 3/4 (171) (43.1) (46.0) (46.0) (48.8) (92.8) (99.0) (99.0) (105.0) 9 13,785 13,785 13,785 14,610 29,690 29,690 29,690 31,470 (229) (61.3) (61.3) (61.3) (65.0) (132.1) (132.1) (132.1) (140.0) 15 22,975 22,975 22,975 24,350 49,480 49,480 49,480 52,450 (381) (102.2) (102.2) (102.2) (108.3) (220.1) (220.1) (220.1) (233.3) 3-1/2 3,620 3,965 4,575 5,160 7,790 8,535 9,855 12,070 (89) (16.1) (17.6) (20.4) (23.0) (34.7) (38.0) (43.8) (53.7) 7-7/8 10,955 10,955 10,955 11,610 26,300 27,880 27,880 29,555 7/8 (200) (48.7) (48.7) (48.7) (51.6) (117.0) (124.0) (124.0) (131.5) 10-1/2 14,605 14,605 14,605 15,480 37,175 37,175 37,175 39,405 (267) (65.0) (65.0) (65.0) (68.9) (165.4) (165.4) (165.4) (175.3) 17-1/2 24,340 24,340 24,340 25,800 61,960 61,960 61,960 65,680 (445) (108.3) (108.3) (108.3) (114.8) (275.6) (275.6) (275.6) (292.2) 4 4,420 4,840 5,590 6,225 9,520 10,430 12,040 14,750 (102) (19.7) (21.5) (24.9) (27.7) (42.3) (46.4) (53.6) (65.6) 9 13,220 13,220 13,220 14,010 32,130 33,645 33,645 35,665 1 (229) (58.8) (58.8) (58.8) (62.3) (142.9) (149.7) (149.7) (158.6) 12 17,625 17,625 17,625 18,680 44,860 44,860 44,860 47,555 (305) (78.4) (78.4) (78.4) (83.1) (199.5) (199.5) (199.5) (211.5) 20 29,375 29,375 29,375 31,135 74,770 74,770 74,770 79,255 (508) (130.7) (130.7) (130.7) (138.5) (332.6) (332.6) (332.6) (352.5) 5 6,175 6,765 7,815 8,355 13,305 14,575 16,830 20,610 (127) (27.5) (30.1) (34.8) (37.2) (59.2) (64.8) (74.9) (91.7) 11-1/4 17,740 17,740 17,740 18,800 44,905 45,150 45,150 47, /4 (286) (78.9) (78.9) (78.9) (83.6) (199.7) (200.8) (200.8) (212.9) 15 23,650 23,650 23,650 25,070 60,200 60,200 60,200 63,815 (381) (105.2) (105.2) (105.2) (111.5) (267.8) (267.8) (267.8) (283.9) 25 39,415 39,415 39,415 41, , , , ,355 (635) (175.3) (175.3) (175.3) (185.8) (446.3) (446.3) (446.3) (473.1) 1 See Section for explanation on development of load values. 2 See Section to convert design strength (factored resistance) value to ASD value. 3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 4 Apply spacing, edge distance, and concrete thickness factors in Tables as necessary. Compare to the steel values in Table 25. The lesser of the values is to be used for the design. 5 Data is for temperature range A: Max. short term temperature = 110 F (43 C), max. long term temperature = 80 F (26 C). For temperature range B: Max. short term temperature = 162 F (72 C), max. long term temperature = 110 F (43 C) multiply above value by Short term elevated concrete temperatures are those that occur over brief intervals, e.g., as a result of diurnal cycling. Long term concrete temperatures are roughly constant over significant periods of time. 6 Tabular values are for dry concrete conditions. For water saturated concrete multiply design strength (factored resistance) by For water-filled drilled holes multiply design strength (factored resistance) by For submerged (under water) applications multiply design strength (factored resistance) by Tabular values are for short term loads only. For sustained loads including overhead use, see Section Tabular values are for normal weight concrete only. For lightweight concrete multiply design strength (factored resistance) by λ a as follows: For sand-lightweight, λ a = For all-lightweight, λ a = Tabular values are for static loads only. For seismic loads, multiply above value by α seis = See section for additional information on seismic applications. 10 Tabular values are for holes drilled in concrete with carbide tipped hammer drill bit. Diamond core drilling is not permitted in cracked concrete conditions. 118 Hilti, Inc. (US) I en español I Hilti (Canada) Corp I I Anchor Fastening Technical Guide 2014

19 HIT-RE 500-SD Epoxy Adhesive Anchoring System Table 25 - Steel design strength (ACI 318 Appendix D Based Design) for Hilti HAS threaded rods 1 Nominal anchor diameter in. 3/8 1/2 5/8 3/4 7/ /4 Tensile 3 ϕn sa HAS-E 2 HAS-Super ASTM A193 B7 2 HAS SS AISI 304/316 SS 2 Shear 4 ϕv sa Seismic Shear 5 ϕv sa Tensile 3 ϕn sa Shear 4 ϕv sa Seismic Shear 5 ϕv sa Tensile 3 ϕn sa Shear 4 ϕv sa Seismic Shear 5 ϕv sa 3,655 1,685 1,180 7,265 3,150 2,205 5,040 2,325 1,628 (16.3) (7.5) (5.2) (32.3) (14.0) (9.8) (22.4) (10.3) (7.2) 6,690 3,705 2,594 13,300 6,915 4,841 9,225 5,110 3,577 (29.8) (16.5) (11.5) (59.2) (30.8) (21.5) (41.0) (22.7) (15.9) 10,650 5,900 4,130 21,190 11,020 7,714 14,690 8,135 5,695 (47.4) (26.2) (18.4) (94.3) (49.0) (34.3) (65.3) (36.2) (25.3) 15,765 8,730 6,111 31,360 16,305 11,414 18,480 10,235 7,165 (70.1) (38.8) (27.2) (139.5) (72.5) (50.8) (82.2) (45.5) (31.9) 21,755 12,050 8,435 43,285 22,505 15,754 25,510 14,125 9,888 (96.8) (53.6) (37.5) (192.5) (100.1) (70.1) (113.5) (62.8) (44.0) 28,540 15,805 11,064 56,785 29,525 20,668 33,465 18,535 12,975 (127.0) (70.3) (49.2) (252.6) (131.3) (91.9) (148.9) (82.4) (57.7) 45,670 25,295 17,707 90,850 47,240 33,068 53,540 29,655 20,759 (203.1) (112.5) (78.8) (404.1) (210.1) (147.1) (238.2) (131.9) (92.3) See Section to convert design strength (factored resistance) value to ASD value. 2 HAS Super rods are considered ductile steel elements. HAS-E and HAS SS rods are considered brittle steel elements. 3 Tensile = ф A se,n f uta as noted in ACI 318 Appendix D 4 Shear = ф 0.60 A se,n f uta as noted in ACI 318 Appendix D 5 Seismic shear values determined by multiplying фv sa x α V,seis where α V,seis = 0.7 for threaded rod. See Section for additional information on seismic applications Hilti, Inc. (US) I en español I Hilti (Canada) Corp I I Anchor Fastening Technical Guide

20 3.2.4 HIT-RE 500-SD Epoxy Adhesive Anchoring System Table 26 - Load adjustment factors for 3/8-in. diameter threaded rods in uncracked concrete 1,2,3 3/8-in. uncracked concrete Embedment in. 2-3/8 3-3/8 4-1/2 7-1/2 2-3/8 3-3/8 4-1/2 7-1/2 2-3/8 3-3/8 4-1/2 7-1/2 2-3/8 3-3/8 4-1/2 7-1/2 2-3/8 3-3/8 4-1/2 7-1/2 2-3/8 3-3/8 4-1/2 7-1/2 h ef (mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) 1-3/4 (44) n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 1-7/8 (48) n/a n/a n/a n/a 2 (51) n/a n/a n/a n/a 3 (76) n/a n/a n/a n/a 3-5/8 (92) n/a n/a n/a 4 (102) n/a n/a n/a 4-5/8 (117) n/a n/a 5 (127) n/a n/a 5-3/4 (146) n/a 6 (152) n/a 7 (178) n/a 8 (203) n/a 8-3/4 (222) (229) (254) (279) (305) (356) (406) (457) (610) (762) (914) > 48 (1219) Table 27 - Load adjustment factors for 3/8-in. diameter threaded rods in cracked concrete 1,2,3 3/8-in. cracked concrete Embedment in. 2-3/8 3-3/8 4-1/2 7-1/2 2-3/8 3-3/8 4-1/2 7-1/2 2-3/8 3-3/8 4-1/2 7-1/2 2-3/8 3-3/8 4-1/2 7-1/2 2-3/8 3-3/8 4-1/2 7-1/2 2-3/8 3-3/8 4-1/2 7-1/2 h ef (mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) 1-3/4 (44) n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 1-7/8 (48) n/a n/a n/a n/a 2 (51) n/a n/a n/a n/a 3 (76) n/a n/a n/a n/a 3-5/8 (92) n/a n/a n/a 4 (102) n/a n/a n/a 4-5/8 (117) n/a n/a 5 (127) n/a n/a 5-3/4 (146) n/a 6 (152) n/a 7 (178) n/a 8 (203) n/a 8-3/4 (222) (229) (254) (279) (305) (356) (406) (457) (610) (762) (914) > 48 (1219) Linear interpolation not permitted 2 Shaded area with reduced edge distance is permitted provided the installation torque is reduced to 0.30 T max for 5d < s < 16-in. and to 0.5 T max for s > 16-in. 3 When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with a thin concrete member) the design can become very conservative. To optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using the design equations from ACI 318 Appendix D. 4 reduction in shear, f AV, assumes an influence of a nearby edge. If no edge exists, then =. 5 reduction factor in shear,, assumes an influence of a nearby edge. If no edge exists, then = Hilti, Inc. (US) I en español I Hilti (Canada) Corp I I Anchor Fastening Technical Guide 2014

21 HIT-RE 500-SD Epoxy Adhesive Anchoring System Table 28 - Load adjustment factors for 1/2-in. diameter threaded rods in uncracked concrete 1,2,3 1/2-in. uncracked concrete Embedment in. 2-3/4 4-1/ /4 4-1/ /4 4-1/ /4 4-1/ /4 4-1/ /4 4-1/ h ef (mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) 1-3/4 (44) n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 2-1/2 (64) n/a n/a n/a n/a 3 (76) n/a n/a n/a n/a 4 (102) n/a n/a n/a 5 (127) n/a n/a n/a 5-3/4 (146) n/a n/a 6 (152) n/a n/a 7 (178) n/a n/a 7-1/4 (184) n/a 8 (203) n/a 9 (229) n/a 10 (254) n/a 11-1/4 (286) (305) (356) (406) (457) (508) (559) (610) (762) (914) > 48 (1219) Table 29 - Load adjustment factors for 1/2-in. diameter threaded rods in cracked concrete 1,2,3 1/2-in. cracked concrete Embedment in. 2-3/4 4-1/ /4 4-1/ /4 4-1/ /4 4-1/ /4 4-1/ /4 4-1/ h ef (mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) 1-3/4 (44) n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 2-1/2 (64) n/a n/a n/a n/a 3 (76) n/a n/a n/a n/a 4 (102) n/a n/a n/a 5 (127) n/a n/a n/a 5-3/4 (146) n/a n/a 6 (152) n/a n/a 7 (178) n/a n/a 7-1/4 (184) n/a 8 (203) n/a 9 (229) n/a 10 (254) n/a 11-1/4 (286) (305) (356) (406) (457) (508) (559) (610) (762) (914) > 48 (1219) Linear interpolation not permitted 2 Shaded area with reduced edge distance is permitted provided the installation torque is reduced to 0.30 T max for 5d < s < 16-in. and to 0.5 T max for s > 16-in. 3 When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with a thin concrete member) the design can become very conservative. To optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using the design equations from ACI 318 Appendix D. 4 reduction in shear,, assumes an influence of a nearby edge. If no edge exists, then =. 5 reduction ƒactor in shear,, assumes an influence of a nearby edge. If no edge exists, then = Hilti, Inc. (US) I en español I Hilti (Canada) Corp I I Anchor Fastening Technical Guide

22 3.2.4 HIT-RE 500-SD Epoxy Adhesive Anchoring System Table 30 - Load adjustment factors for 5/8-in. diameter threaded rods in uncracked concrete 1,2,3 5/8-in. uncracked concrete Embedment in. 3-1/8 5-5/8 7-1/2 12-1/2 3-1/8 5-5/8 7-1/2 12-1/2 3-1/8 5-5/8 7-1/2 12-1/2 3-1/8 5-5/8 7-1/2 12-1/2 3-1/8 5-5/8 7-1/2 12-1/2 3-1/8 5-5/8 7-1/2 12-1/2 h ef (mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) 1-3/4 (44) n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 3-1/8 (79) n/a n/a n/a n/a 4 (102) n/a n/a n/a n/a 4-5/8 (117) n/a n/a n/a 5 (127) n/a n/a n/a 6 (152) n/a n/a n/a 7 (178) n/a n/a n/a 7-1/8 (181) n/a n/a 8 (203) n/a n/a 9 (229) n/a 10 (254) n/a 11 (279) n/a 12 (305) n/a 14 (356) (406) (457) (508) (559) (610) (660) (711) (762) (914) >48 (1219) Table 31 - Load adjustment factors for 5/8-in. diameter threaded rods in cracked concrete 1,2,3 5/8-in. cracked concrete Embedment in. 3-1/8 5-5/8 7-1/2 12-1/2 3-1/8 5-5/8 7-1/2 12-1/2 3-1/8 5-5/8 7-1/2 12-1/2 3-1/8 5-5/8 7-1/2 12-1/2 3-1/8 5-5/8 7-1/2 12-1/2 3-1/8 5-5/8 7-1/2 12-1/2 h ef (mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) 1-3/4 (44) n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 3-1/8 (79) n/a n/a n/a n/a 4 (102) n/a n/a n/a n/a 4-5/8 (117) n/a n/a n/a 5 (127) n/a n/a n/a 6 (152) n/a n/a n/a 7 (178) n/a n/a n/a 7-1/8 (181) n/a n/a 8 (203) n/a n/a 9 (229) n/a 10 (254) n/a 11 (279) n/a 12 (305) n/a 14 (356) (406) (457) (508) (559) (610) (660) (711) (762) (914) >48 (1219) Linear interpolation not permitted 2 Shaded area with reduced edge distance is permitted provided the installation torque is reduced to 0.30 T max for 5d < s < 16-in. and to 0.5 T max for s > 16-in. 3 When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with a thin concrete member) the design can become very conservative. To optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using the design equations from ACI 318 Appendix D. 4 reduction in shear,, assumes an influence of a nearby edge. If no edge exists, then =. 5 reduction factor in shear,, assumes an influence of a nearby edge. If no edge exists, then = Hilti, Inc. (US) I en español I Hilti (Canada) Corp I I Anchor Fastening Technical Guide 2014

23 HIT-RE 500-SD Epoxy Adhesive Anchoring System Table 32 - Load adjustment factors for 3/4-in. diameter threaded rods in uncracked concrete 1,2,3 3/4-in. uncracked concrete Embedment in. 3-1/2 6-3/ /2 6-3/ /2 6-3/ /2 6-3/ /2 6-3/ /2 6-3/ h ef (mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) 1-3/4 (44) n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 3-3/4 (95) n/a n/a n/a n/a 4 (102) n/a n/a n/a n/a 5 (127) n/a n/a n/a n/a 5-1/4 (133) n/a n/a n/a 6 (152) n/a n/a n/a 7 (178) n/a n/a n/a 8 (203) n/a n/a n/a 8-1/2 (216) n/a n/a 9 (229) n/a n/a 10 (254) n/a n/a 10-3/4 (273) n/a 12 (305) n/a 14 (356) n/a 16 (406) n/a 16-3/4 (425) (457) (508) (559) (610) (660) (711) (762) (914) > 48 (1219) Table 33 - Load adjustment factors for 3/4-in. diameter threaded rods in cracked concrete 1,2,3 3/4-in. cracked concrete Embedment in. 3-1/2 6-3/ /2 6-3/ /2 6-3/ /2 6-3/ /2 6-3/ /2 6-3/ h ef (mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) 1-3/4 (44) n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 3-3/4 (95) n/a n/a n/a n/a 4 (102) n/a n/a n/a n/a 5 (127) n/a n/a n/a n/a 5-1/4 (133) n/a n/a n/a 6 (152) n/a n/a n/a 7 (178) n/a n/a n/a 8 (203) n/a n/a n/a 8-1/2 (216) n/a n/a 9 (229) n/a n/a 10 (254) n/a n/a 10-3/4 (273) n/a 12 (305) n/a 14 (356) n/a 16 (406) n/a 16-3/4 (425) (457) (508) (559) (610) (660) (711) (762) (914) > 48 (1219) Linear interpolation not permitted 2 Shaded area with reduced edge distance is permitted provided the installation torque is reduced to 0.30 T max for 5d < s < 16-in. and to 0.5 T max for s > 16-in. 3 When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with a thin concrete member) the design can become very conservative. To optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using the design equations from ACI 318 Appendix D. 4 reduction in shear,, assumes an influence of a nearby edge. If no edge exists, then =. 5 reduction factor in shear,, assumes an influence of a nearby edge. If no edge exists, then = Hilti, Inc. (US) I en español I Hilti (Canada) Corp I I Anchor Fastening Technical Guide

24 3.2.4 HIT-RE 500-SD Epoxy Adhesive Anchoring System Table 34 - Load adjustment factors for 7/8-in. diameter threaded rods in uncracked concrete 1,2,3 7/8-in. uncracked concrete Embedment in. 3-1/2 7-7/8 10-1/2 17-1/2 3-1/2 7-7/8 10-1/2 17-1/2 3-1/2 7-7/8 10-1/2 17-1/2 3-1/2 7-7/8 10-1/2 17-1/2 3-1/2 7-7/8 10-1/2 17-1/2 3-1/2 7-7/8 10-1/2 17-1/2 h ef (mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) 1-3/4 (44) n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 4-3/8 (111) n/a n/a n/a n/a 5 (127) n/a n/a n/a n/a 5-1/2 (140) n/a n/a n/a 6 (152) n/a n/a n/a 7 (178) n/a n/a n/a 8 (203) n/a n/a n/a 9 (229) n/a n/a n/a 9-7/8 (251) n/a n/a 10 (254) n/a n/a 11 (279) n/a n/a 12 (305) n/a n/a 12-1/2 (318) n/a 14 (356) n/a 16 (406) n/a 18 (457) n/a 19-1/2 (495) (508) (559) (610) (660) (711) (762) (914) > 48 (1219) Table 35 - Load adjustment factors for 7/8-in. diameter threaded rods in cracked concrete 1,2,3 7/8-in. cracked concrete Embedment in. 3-1/2 7-7/8 10-1/2 17-1/2 3-1/2 7-7/8 10-1/2 17-1/2 3-1/2 7-7/8 10-1/2 17-1/2 3-1/2 7-7/8 10-1/2 17-1/2 3-1/2 7-7/8 10-1/2 17-1/2 3-1/2 7-7/8 10-1/2 17-1/2 h ef (mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) 1-3/4 (44) n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 4-3/8 (111) n/a n/a n/a n/a 5 (127) n/a n/a n/a n/a 5-1/2 (140) n/a n/a n/a 6 (152) n/a n/a n/a 7 (178) n/a n/a n/a 8 (203) n/a n/a n/a 9 (229) n/a n/a n/a 9-7/8 (251) n/a n/a 10 (254) n/a n/a 11 (279) n/a n/a 12 (305) n/a n/a 12-1/2 (318) n/a 14 (356) n/a 16 (406) n/a 18 (457) n/a 19-1/2 (495) (508) (559) (610) (660) (711) (762) (914) > 48 (1219) Linear interpolation not permitted 2 Shaded area with reduced edge distance is permitted provided the installation torque is reduced to 0.30 T max for 5d < s < 16-in. and to 0.5 T max for s > 16-in. 3 When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with a thin concrete member) the design can become very conservative. To optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using the design equations from ACI 318 Appendix D. 4 reduction in shear,, assumes an influence of a nearby edge. If no edge exists, then =. 5 reduction factor in shear,, assumes an influence of a nearby edge. If no edge exists, then = Hilti, Inc. (US) I en español I Hilti (Canada) Corp I I Anchor Fastening Technical Guide 2014

25 HIT-RE 500-SD Epoxy Adhesive Anchoring System Table 36 - Load adjustment factors for 1-in. diameter threaded rods in uncracked concrete 1,2,3 1-in. uncracked concrete in Embedment h ef (mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) 1-3/4 (44) n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 5 (127) n/a n/a n/a n/a 6 (152) n/a n/a n/a n/a 6-1/4 (159) n/a n/a n/a 7 (178) n/a n/a n/a 8 (203) n/a n/a n/a 9 (229) n/a n/a n/a 10 (254) n/a n/a n/a 11 (279) n/a n/a n/a 11-1/4 (286) n/a n/a 12 (305) n/a n/a 13 (330) n/a n/a 14 (356) n/a n/a 14-1/4 (362) n/a 16 (406) n/a 18 (457) n/a 20 (508) n/a 22 (559) n/a 22-1/4 (565) (610) (660) (711) (762) (914) > 48 (1219) Table 37 - Load adjustment factors for 1-in. diameter threaded rods in cracked concrete 1,2,3 1-in. cracked concrete in Embedment h ef (mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) 1-3/4 (44) n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 5 (127) n/a n/a n/a n/a 6 (152) n/a n/a n/a n/a 6-1/4 (159) n/a n/a n/a 7 (178) n/a n/a n/a 8 (203) n/a n/a n/a 9 (229) n/a n/a n/a 10 (254) n/a n/a n/a 11 (279) n/a n/a n/a 11-1/4 (286) n/a n/a 12 (305) n/a n/a 13 (330) n/a n/a 14 (356) n/a n/a 14-1/4 (362) n/a 16 (406) n/a 18 (457) n/a 20 (508) n/a 22 (559) n/a 22-1/4 (565) (610) (660) (711) (762) (914) > 48 (1219) Linear interpolation not permitted 2 Shaded area with reduced edge distance is permitted provided the installation torque is reduced to 0.30 T max for 5d < s < 16-in. and to 0.5 T max for s > 16-in. 3 When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with a thin concrete member) the design can become very conservative. To optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using the design equations from ACI 318 Appendix D. 4 reduction in shear,, assumes an influence of a nearby edge. If no edge exists, then =. 5 reduction factor in shear,, assumes an influence of a nearby edge. If no edge exists, then = Hilti, Inc. (US) I en español I Hilti (Canada) Corp I I Anchor Fastening Technical Guide

26 3.2.4 HIT-RE 500-SD Epoxy Adhesive Anchoring System Table 38 - Load adjustment factors for 1-1/4-in. diameter threaded rods in uncracked concrete 1,2,3 1-1/4-in. uncracked concrete in / / / / / / Embedment h ef (mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) 1-3/4 (44) n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 6-1/4 (159) n/a n/a n/a n/a 7 (178) n/a n/a n/a n/a 8 (203) n/a n/a n/a 9 (229) n/a n/a n/a 10 (254) n/a n/a n/a 11 (279) n/a n/a n/a 12 (305) n/a n/a n/a 13 (330) n/a n/a n/a 14 (356) n/a n/a 14-1/4 (362) n/a n/a 15 (381) n/a n/a 16 (406) n/a n/a 17 (432) n/a n/a 18 (457) n/a 20 (508) n/a 22 (559) n/a 24 (610) n/a 26 (660) n/a 28 (711) (762) (914) > 48 (1219) Table 39 - Load adjustment factors for 1-1/4-in. diameter threaded rods in cracked concrete 1,2,3 1-1/4-in. cracked concrete in / / / / / / Embedment h ef (mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) 1-3/4 (44) n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 6-1/4 (159) n/a n/a n/a n/a 7 (178) n/a n/a n/a n/a 8 (203) n/a n/a n/a 9 (229) n/a n/a n/a 10 (254) n/a n/a n/a 11 (279) n/a n/a n/a 12 (305) n/a n/a n/a 13 (330) n/a n/a n/a 14 (356) n/a n/a 14-1/4 (362) n/a n/a 15 (381) n/a n/a 16 (406) n/a n/a 17 (432) n/a n/a 18 (457) n/a 20 (508) n/a 22 (559) n/a 24 (610) n/a 26 (660) n/a 28 (711) (762) (914) > 48 (1219) Linear interpolation not permitted 2 Shaded area with reduced edge distance is permitted provided the installation torque is reduced to 0.30 T max for 5d < s < 16-in. and to 0.5 T max for s > 16-in. 3 When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with a thin concrete member) the design can become very conservative. To optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using the design equations from ACI 318 Appendix D. 4 reduction in shear,, assumes an influence of a nearby edge. If no edge exists, then =. 5 reduction factor in shear,, assumes an influence of a nearby edge. If no edge exists, then = Hilti, Inc. (US) I en español I Hilti (Canada) Corp I I Anchor Fastening Technical Guide 2014

27 HIT-RE 500-SD Epoxy Adhesive Anchoring System HIT-RE 500-SD with HIS-N Inserts Table 40 - HIS-N and HIS-RN specifications Setting information Symbol Units Thread size 3/8-16 UNC 1/2-13 UNC 5/8-11 UNC 3/4-10 UNC Outside diameter of insert in Nominal bit diameter d o in. 11/16 7/8 1-1/8 1-1/4 Effective embedment h ef in. 4-3/ /4 8-1/8 (mm) (110) (125) (170) (205) Thread engagement minimum in. 3/8 1/2 5/8 3/4 h maximum s in. 15/16 1-3/16 1-1/2 1-7/8 Installation torque T inst ft-lb (Nm) (20) (40) (81) (136) h min in (mm) (150) (170) (230) (270) Figure 3 - HIS-N and HIS-RN specifications HIS-N internally threaded insert specifications 3/8-in. HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN with a minimum tensile strength of 71.1 ksi (490 MPa) and a minimum yield strength of 59.5 ksi (410 MPa). 1/2-, 5/8- and 3/4-in. HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN with a minimum tensile strength of 66.7 ksi (460 MPa) and a minimum yield strength of 54.4 ksi (375 MPa). HIS-RN is manufactured from X5CrNiMo K700 stainless steel conforming to DIN EN with a minimum tensile strength of ksi (700 MPa) and a minimum yield strength of 50.8 ksi (350 MPa) Hilti, Inc. (US) I en español I Hilti (Canada) Corp I I Anchor Fastening Technical Guide

28 3.2.4 HIT-RE 500-SD Epoxy Adhesive Anchoring System Table 41 - Hilti HIT-RE 500-SD adhesive design strength (factored resistance) with concrete / bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete 1,2,3,4,5,6,7,8,10 Tension ФN n or N r Shear ФV n or V r Thread size 3/8-16 UNC 1/2-13 UNC 5/8-11 UNC 3/4-10 UNC Effective embedment in. (mm) ƒ c = 2500 psi (17.2 Mpa) ƒ c = 3000 psi (20.7 Mpa) ƒ c = 4000 psi (27.6 Mpa) ƒ c = 6000 psi (41.4 Mpa) ƒ c = 2500 psi (17.2 Mpa) ƒ c = 3000 psi (20.7 Mpa) ƒ c = 4000 psi (27.6 Mpa) ƒ c = 6000 psi (41.4 Mpa) 4-3/8 7,140 7,820 9,030 11,060 15,375 16,840 19,445 23,815 (111) (31.8) (34.8) (40.2) (49.2) (68.4) (74.9) (86.5) (105.9) 5 8,720 9,555 11,030 13,510 18,785 20,575 23,760 29,100 (127) (38.8) (42.5) (49.1) (60.1) (83.6) (91.5) (105.7) (129.4) 6-3/4 13,680 14,985 17,305 21,190 29,460 32,275 37,265 45,645 (171) (60.9) (66.7) (77.0) (94.3) (131.0) (143.6) (165.8) (203.0) 8-1/8 18,065 19,790 22,850 27,985 38,910 42,620 49,215 60,275 (206) (80.4) (88.0) (101.6) (124.5) (173.1) (189.6) (218.9) (268.1) Table 42 - Hilti HIT-RE 500-SD adhesive design strength (factored resistance) with concrete / bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete 1,2,3,4,5,6,7,8,9,10 Tension ФN n or N r Shear ФV n or V r Thread size 3/8-16 UNC 1/2-13 UNC 5/8-11 UNC 3/4-10 UNC Effective embedment in. (mm) ƒ c = 2500 psi (17.2 Mpa) ƒ c = 3000 psi (20.7 Mpa) ƒ c = 4000 psi (27.6 Mpa) ƒ c = 6000 psi (41.4 Mpa) ƒ c = 2500 psi (17.2 Mpa) ƒ c = 3000 psi (20.7 Mpa) ƒ c = 4000 psi (27.6 Mpa) ƒ c = 6000 psi (41.4 Mpa) 4-3/8 5,055 5,540 6,040 6,400 10,890 11,930 13,010 13,790 (111) (22.5) (24.6) (26.9) (28.5) (48.4) (53.1) (57.9) (61.3) 5 6,175 6,765 7,815 8,370 13,305 14,575 16,830 18,030 (127) (27.5) (30.1) (34.8) (37.2) (59.2) (64.8) (74.9) (80.2) 6-3/4 9,690 9,855 9,855 10,445 20,870 22,860 25,085 26,590 (171) (43.1) (43.8) (43.8) (46.5) (92.8) (101.7) (111.6) (118.3) 8-1/8 12,320 12,320 12,320 13,060 27,560 30,190 31,355 33,240 (206) (54.8) (54.8) (54.8) (58.1) (122.6) (134.3) (139.5) (147.9) 1 See Section for explanation on development of load values. 2 See Section to convert design strength (factored resistance) value to ASD value. 3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 4 Apply spacing, edge distance, and concrete thickness factors in Tables as necessary. Compare to the steel values in Table 43. The lesser of the values is to be used for the design. 5 Data is for temperature range A: Max. short term temperature = 110 F (43 C), max. long term temperature = 80 F (26 C). For temperature range B: Max. short term temperature = 162 F (72 C), max. long term temperature = 110 F (43 C) multiply above value by Short term elevated concrete temperatures are those that occur over brief intervals, e.g., as a result of diurnal cycling. Long term concrete temperatures are roughly constant over significant periods of time. 6 Tabular values are for dry concrete conditions. For water saturated concrete multiply design strength (factored resistance) by For water-filled drilled holes multiply design strength (factored resistance) by For submerged (under water) applications multiply design strength (factored resistance) by Tabular values are for short term loads only. For sustained loads including overhead use, see Section Tabular values are for normal weight concrete only. For lightweight concrete multiply design strength (factored resistance) by λ a as follows: For sand-lightweight, λ a = For all-lightweight, λ a = Tabular values are for static loads only. For seismic loads, multiply above value by α seis = See section for additional information on seismic applications. 10 Tabular values are for holes drilled in concrete with carbide tipped hammer drill bit. For diamond core drilling multiply above value by Diamond core drilling is not permitted cracked concrete and is not permitted for the water-filled or underwater (submerged) applications. 128 Hilti, Inc. (US) I en español I Hilti (Canada) Corp I I Anchor Fastening Technical Guide 2014

29 HIT-RE 500-SD Epoxy Adhesive Anchoring System Table 43 - Steel design strength (factored resistance) for steel bolt / cap screw for Hilti HIS-N and HIS-RN internally threaded inserts 1 Thread size 3/8-16 UNC 1/2-13 UNC 5/8-11 UNC 3/4-10 UNC Tensile 3 ϕn sa ACI 318 Appendix D Based Design ASTM A193 Grade B8M ASTM A193 B7 2 stainless steel 2 Shear 4 ϕv sa Seismic Shear 5 ϕv sa Tensile 3 ϕn sa Shear 4 ϕv sa Seismic Shear 5 ϕv sa 6,300 3,490 2,443 5,540 3,070 2,149 (28.0) (15.5) (10.9) (24.6) (13.7) (9.6) 11,530 6,385 4,470 10,145 5,620 3,934 (51.3) (28.4) (19.9) (45.1) (25.0) (17.5) 18,365 10,170 7,119 16,160 8,950 6,265 (81.7) (45.2) (31.7) (71.9) (39.8) (27.9) 27,180 15,055 10,539 23,915 13,245 9,272 (120.9) (67.0) (46.9) (106.4) (58.9) (41.2) 1 See Section to convert design strength (factored resistance) value to ASD value. 2 Steel bolt / cap screw for Hilti HIS-N and HIS-RN inserts are considered brittle steel elements. 3 Tensile = ф A se,n f uta as noted in ACI 318 Appendix D 4 Shear = ф 0.60 A se,n f uta as noted in ACI 318 Appendix D. 5 Seismic shear values determined by multiplying ф V sa x α V,seis where α V,seis = 0.7 for steel bolt. See Section for additional information on seismic applications Hilti, Inc. (US) I en español I Hilti (Canada) Corp I I Anchor Fastening Technical Guide

30 3.2.4 HIT-RE 500-SD Epoxy Adhesive Anchoring System Table 44 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete 1,2.3 HIS-N and HIS-RN all diameters uncracked concrete Thread size Edge Distance in Shear in. 3/8 1/2 5/8 3/4 3/8 1/2 5/8 3/4 3/8 1/2 5/8 3/4 3/8 1/2 5/8 3/4 3/8 1/2 5/8 3/4 3/8 1/2 5/8 3/4 Embedment in. 4-3/ /4 8-1/8 4-3/ /4 8-1/8 4-3/ /4 8-1/8 4-3/ /4 8-1/8 4-3/ /4 8-1/8 4-3/ /4 8-1/8 h ef (mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) 3-1/4 (83) 0.59 n/a n/a n/a 0.34 n/a n/a n/a 0.55 n/a n/a n/a 0.15 n/a n/a n/a 0.31 n/a n/a n/a n/a n/a n/a n/a 4 (102) n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 5 (127) n/a n/a n/a n/a n/a n/a n/a n/a n/a 5-1/2 (140) n/a n/a n/a n/a 6 (152) n/a n/a n/a 7 (178) n/a n/a 8 (203) n/a n/a 9 (229) n/a n/a 10 (254) n/a 11 (279) (305) (356) (406) (457) (610) (762) (914) > 48 (1219) Table 45 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete 1,2.3 HIS-N and HIS-RN all diameters cracked concrete Thread size Edge Distance in Shear in. 3/8 1/2 5/8 3/4 3/8 1/2 5/8 3/4 3/8 1/2 5/8 3/4 3/8 1/2 5/8 3/4 3/8 1/2 5/8 3/4 3/8 1/2 5/8 3/4 Embedment in. 4-3/ /4 8-1/8 4-3/ /4 8-1/8 4-3/ /4 8-1/8 4-3/ /4 8-1/8 4-3/ /4 8-1/8 4-3/ /4 8-1/8 h ef (mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) 3-1/4 (83) 0.59 n/a n/a n/a 0.54 n/a n/a n/a 0.55 n/a n/a n/a 0.16 n/a n/a n/a 0.31 n/a n/a n/a n/a n/a n/a n/a 4 (102) n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 5 (127) n/a n/a n/a n/a n/a n/a n/a n/a n/a 5-1/2 (140) n/a n/a n/a n/a 6 (152) n/a n/a n/a 7 (178) n/a n/a 8 (203) n/a n/a 9 (229) n/a n/a 10 (254) n/a 11 (279) (305) (356) (406) (457) (610) (762) (914) > 48 (1219) Linear interpolation not permitted 2 Shaded area with reduced edge distance is permitted provided the installation torque is reduced to 0.30 T max for 5d < s < 16-in. and to 0.5 T max for s > 16-in. 3 When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with a thin concrete member) the design can become very conservative. To optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using the design equations from ACI 318 Appendix D. 4 reduction in shear,, assumes an influence of a nearby edge. If no edge exists, then =. 5 reduction factor in shear,, assumes an influence of a nearby edge. If no edge exists, then = Hilti, Inc. (US) I en español I Hilti (Canada) Corp I I Anchor Fastening Technical Guide 2014

31 HIT-RE 500-SD Epoxy Adhesive Anchoring System Installation instructions Installation Instructions For Use (IFU) are included with each product package. They can also be viewed or downloaded online at (US) and (Canada). Because of the possibility of changes, always verify that downloaded IFU are current when used. Proper installation is critical to achieve full performance. Training is available on request. Contact Hilti Technical Services for applications and conditions not addressed in the IFU. HIT-RE 500-SD volume charts Table 46 - Threaded rod installation Nominal anchor diameter in. Nominal bit diameter in. Adhesive volume required per inch of embedment in 3 1/4 5/ /8 7/ /2 9/ /8 3/ /4 7/ / / /4 1-3/ The useable volume of HIT-RE 500-SD refill cartridge is 16.5 in 3 (270 ml) The useable volume of HIT-RE 500-SD medium refill is 26.9 in 3 (440 ml) The useable volume of HIT-RE 500-SD medium refill is 81.8 in 3 (1340 ml) Example: 5/8-in. diameter rod with an embedment of 10 inches: 10 in. x 0.26 in 3 /in. = 2.6 in 3 /fastening 16.5 in 3 /cartridge 2.6 in 3 /fastening 6 fastenings/cartridge 81.8 in 3 /cartridge 2.6 in 3 /fastening 31 fastenings/cartridge Table 48 - HIT-RE 500-SD cure time Base material temperature F C Gel Time Full Cure h 72 h h 48 h h 24 h min 12 h min 8 h min 4 h Table 47 - Rebar installation 1 Adhesive volume required Rebar size Nominal bit 1 diameter in. per Inch of embedment in 3 #3 1/ #4 5/ #5 3/ #6 7/ # #8 1-1/ #9 1-3/ #10 1-1/ #11 1-3/ Rebar diameter may vary. Use smallest drill bit which will accommodate rebar. Table 49 - Resistance of HIT-RE 500-SD to chemicals Chemical Chemicals Tested Resistant Alkaline Concrete drilling mud (10%) ph= Concrete drilling mud (10%) ph= Concrete potash solution (10%) + ph=14.0 Acids Acetic acid (10%) 1 Nitric acid (10%) 1 Hydrochloric acid (10%) 3 month - Sulfuric acid (10%) Solvents Benzyl alcohol Ethanol Ethyl acetate Methyl ethyl ketone (MEK) Trichlorethylene Xylene (mixture) + Chemicals used on job sites Environmental chemicals Concrete plasticizer Diesel oil Oil Petrol Oil for form work (forming oil) Salt water de-mineralized water salt spraying test SO 2 Environment/weather 1 Concrete was dissolved by acid Not Resistant Hilti, Inc. (US) I en español I Hilti (Canada) Corp I I Anchor Fastening Technical Guide

32 3.2.4 HIT-RE 500-SD Epoxy Adhesive Anchoring System Ordering information 1 HIT-RE 500-SD Epoxy Adhesive Order information Description Package contents Qty of foil packs HIT-RE 500-SD (11.1 fl oz/330 ml) Includes (1) foil pack with (1) mixer and 3/8 filler tube per pack 1 HIT-RE 500-SD Master Carton (11.1 fl oz/330 ml) Includes (1) master carton containing (25) foil packs with (1) mixer and 3/8 25 filler tube per pack HIT-RE 500-SD Combo (11.1 fl oz/330 ml) Includes (1) master carton containing (25) foil packs with (1) mixer and 3/8 25 filler tube per pack and (1) HDM 500 manual dispenser HIT-RE 500-SD Master Carton (16.9 fl oz/500 ml) Includes (1) master carton containing (20) foil packs with (1) mixer and 3/8 20 filler tube per pack HIT-RE 500-SD Combo (16.9 fl oz/500 ml) Includes (2) master cartons containing (20) foil packs each with (1) mixer 40 and 3/8 filler tube per pack and (1) HDM 500 manual dispenser HIT-RE 500-SD Jumbo (47.3 fl oz/1400 ml) Includes (4) jumbo foil packs with (1) mixer and 3/8 filler tube per pack 4 HIT-RE 500-SD Jumbo (47.3 fl oz/1400 ml) Includes (64) jumbo foil packs with (1) mixer and 3/8 filler tube per pack 64 Pallet Combo and (1) P8000 pneumatic dispenser HIT-RE-M Static Mixer For use with HIT-RE 500-SD cartridges 1 1 For complete information about Hilti anchors, adhesive anchoring dispensers, drilled hole preparation and other adhesive anchoring accessories, see HIT-HY 200 Anchoring System, Section Ordering Information. Fastener Components HDE 500 Battery Dispenser HAS Threaded Rods HIS-N Internally Threaded Inserts HIT RE Mixer HIT-RE 500-SD Refill Pack Refill Pack Holder P3500 Dispenser Rebar (supplied by contractor) HIT-RE 500-SD Medium Cartridge HDM 500 Manual Dispenser HIT-RE 500-SD Jumbo Cartridge Refill Pack Holder P8000D Dispenser 132 Hilti, Inc. (US) I en español I Hilti (Canada) Corp I I Anchor Fastening Technical Guide 2014

Mechanical Anchoring Systems HDA Undercut Anchor Product description. HDA-P Undercut Anchor Pre-Set Type

Mechanical Anchoring Systems HDA Undercut Anchor Product description. HDA-P Undercut Anchor Pre-Set Type Mechanical Anchoring Systems 3.3 3.3.1 HDA Undercut Anchor 3.3.1.1 Product description The Hilti HDA undercut anchor is a heavy-duty mechanical anchor with carbide-tipped undercut segments used to perform

More information

HIT-HY 200 Adhesive Anchor Technical Supplement. One giant leap. Hilti. Outperform. Outlast.

HIT-HY 200 Adhesive Anchor Technical Supplement. One giant leap. Hilti. Outperform. Outlast. HIT-HY 200 Adhesive Anchor Technical Supplement One giant leap. Hilti. Outperform. Outlast. HIT-HY 200 Safe Set Technology One giant leap. The new Hilti HIT-HY 200 Adhesive Anchoring System is out of this

More information

TZ WEDGE ANCHOR FOR CRACKED AND UNCRACKED CONCRETE

TZ WEDGE ANCHOR FOR CRACKED AND UNCRACKED CONCRETE www.ucanfast.com TECHNICAL MANUAL SECTION 2.2 PAGE 1 / 10 ä DESCRIPTION UCAN TZ torque controlled mechanical expansion wedge anchors have a Category 1 classification. They are used to resist static, wind

More information

CIA-EA Technical Data Sheet

CIA-EA Technical Data Sheet Description Our CIA-EA Epoxy Acrylate adhesive anchor system has been specially formulated as a high-performance, two component adhesive anchor system for threaded bars in uncracked concrete. Base Material

More information

Hilti, Inc South 122 nd East Avenue Tulsa, OK

Hilti, Inc South 122 nd East Avenue Tulsa, OK Attached are page(s) from the 2011 Hilti North American Product Tech Guide. For complete details on this product, including data development, product specifications, general suitability, installation,

More information

The following excerpt are pages from the North American Product Technical Guide, Volume 2: Anchor Fastening, Edition 16.1.

The following excerpt are pages from the North American Product Technical Guide, Volume 2: Anchor Fastening, Edition 16.1. The following exerpt are pages from the North Amerian Produt Tehnial Guide, Volume 2: Anhor Fastening, Edition 16.1. Please refer to the publiation in its entirety for omplete details on this produt inluding

More information

The following excerpt are pages from the North American Product Technical Guide, Volume 2: Anchor Fastening, Edition 16.

The following excerpt are pages from the North American Product Technical Guide, Volume 2: Anchor Fastening, Edition 16. The following exerpt are pages from the North Amerian Produt Tehnial Guide, Volume 2: Anhor Fastening, Edition 16. Please refer to the publiation in its entirety for omplete details on this produt inluding

More information

CHEMICAL. Straight cut rod is provided in the materials listed below and includes nuts / washers.

CHEMICAL. Straight cut rod is provided in the materials listed below and includes nuts / washers. 161 STRAIGHT CUT ROD Straight cut rod is provided in the materials listed below and includes nuts / washers. Straight Rod 22-1/2 Bent Rod A 307 THREADED ANCHOR ROD, ZINC PLATED (ASTM B633, CLEAR CHROMATE)

More information

WEDGE-ALL Wedge Anchors

WEDGE-ALL Wedge Anchors WEDGE-ALL Wedge Anchors The Wedge-All wedge anchors are a non-bottom bearing, wedge-style expansion anchor for use in solid concrete or grout-fi lled masonry. A one-piece clip ensures uniform holding capacity

More information

fischer Epoxy Mortar FIS EB The basic epoxy mortar for applications in concrete

fischer Epoxy Mortar FIS EB The basic epoxy mortar for applications in concrete fischer Epoxy Mortar FIS EB The basic epoxy mortar for applications in concrete For standard applications in concrete and rebar connections. Advantages at a glance Epoxy mortar for applications in concrete

More information

Submittal / Substitution Request

Submittal / Substitution Request Submittal / Substitution Request SUBMITTED TO: To: Firm: Project: Submitted Product: SIMPSON STRONG-TIE WEDGE-ALL WEDGE ANCHOR Specified Product: Section: Page: Detail/Sheet No.: Description of Application:

More information

fischer Epoxy Mortar FIS EB

fischer Epoxy Mortar FIS EB fischer Epoxy Mortar FIS EB The basic epoxy mortar for applications in concrete ETA-15/0771 ETAG 001-5 Post-installed rebar connection (TR2 fischer Epoxy Mortar FIS EB: For standard applications in concrete

More information

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS 0 Most Widely Accepted and Trusted ICC ES Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2691 Reissued 04/2017 This report is subject to renewal 04/2019. DIVISION: 03 00 00 CONCRETE

More information

l DESCRIPTION l FEATURES l LIMITATIONS l TYPICAL APPLICATIONS l MATERIAL SPECIFICATIONS TECHNICAL MANUAL SECTION 2.3 PAGE 1 / 6

l DESCRIPTION l FEATURES l LIMITATIONS l TYPICAL APPLICATIONS l MATERIAL SPECIFICATIONS TECHNICAL MANUAL SECTION 2.3 PAGE 1 / 6 www.ucanfast.com TECHNICAL MANUAL SECTION 2.3 PAGE 1 / 6 l DESCRIPTION The UCAN WAG anchor is a fully threaded torque controlled expansion anchor assembled with a three segment expansion clip. All parts

More information

Drop-In Internally Threaded Anchor (DIAB) Mechanical Anchors. Key features. Material: Carbon steel. Coating: Zinc plated

Drop-In Internally Threaded Anchor (DIAB) Mechanical Anchors. Key features. Material: Carbon steel. Coating: Zinc plated Drop-In Internally Threaded Anchor (DIAB) Expansion shell anchors for use in solid base materials Simpson Strong-Tie introduces a new, redesigned Drop-In Anchor (DIAB) that provides easier installation

More information

Anchor Component Material Standard Mechanical Properties

Anchor Component Material Standard Mechanical Properties SECTION 4.1 PAGE 1 / 5 l description The UCAN sleeve anchor is a light-medium duty anchor ideal for applications in concrete, hollow block and brick. It is a mechanical expansion anchor assembled with

More information

Injection mortar FIS VL

Injection mortar FIS VL Injection mortar FIS VL The solid injection mortar for standard applications in cracked concrete and masonry High-bay warehouses BUILDING MATERIALS Approved for anchorings in: Concrete C20/25 to C50/60,

More information

TorqBolt Wedge Anchors Torque Controlled Expansion Anchor

TorqBolt Wedge Anchors Torque Controlled Expansion Anchor TorqBolt Wedge Anchors Torque Controlled Expansion Anchor Product Description The Torqbolt wedge anchor is a torque-controlled, wedge expansion anchor for heavy duty fastening applications where high pull

More information

Brick & Concrete. Expandet ESI Xtreme Pro Injection Mortar ADVANTAGES. ACCESSORIES Wide range of accessories. INSTALLATION:

Brick & Concrete. Expandet ESI Xtreme Pro Injection Mortar ADVANTAGES. ACCESSORIES Wide range of accessories. INSTALLATION: Expandet ESI Xtreme Pro Injection Mortar Expandet ESI Xtreme Pro is the professional all round bonded anchor solution that provides expansion free, safe and fast anchorage of threaded rod, socket anchors

More information

DURAL HS GEL High Strength Epoxy Gel for Anchoring and Doweling

DURAL HS GEL High Strength Epoxy Gel for Anchoring and Doweling The Euclid Chemical Company DURAL HS GEL High Strength Epoxy Gel for Anchorg and Dowelg Description DURAL HS GEL is a two component, 1:1 mix ratio, structural epoxy system that offers exceptional strength

More information

Highbond anchor FHB II-A S

Highbond anchor FHB II-A S Highbond anchor FHB II-A S The best performance in cracked concrete with the least installation effort VERSIONS APPROVALS zinc-plated steel stainless steel high corrosion-resistant steel ADVANTAGES BUILDING

More information

Ancholt Bolt Design With Tension and Shear Using Anchor Reinforcement

Ancholt Bolt Design With Tension and Shear Using Anchor Reinforcement Page 1 of 8 ANCHOR BOLT DESIGN Combined Tension and Shear Result Summary Anchor Rod Embedment, Spacing and Edge Distance OK Min Rquired Anchor Reinft. Development Length ratio = 0.87 OK Overall ratio =

More information

Also suitable for: Concrete C12/15. For fixing of: Steel constructions Railings Consoles Ladders Wooden constructions Cable trays Machines Staircases

Also suitable for: Concrete C12/15. For fixing of: Steel constructions Railings Consoles Ladders Wooden constructions Cable trays Machines Staircases 28 Highbond anchor FHB II Flexible installation and highest loads in the cracked tensile zone. OVERVIEW FHB II-A S (standard), zinc plated steel FHB II-A L (performance optimised), zinc-plated steel Resin

More information

MULTI-MONTI Technical manual

MULTI-MONTI Technical manual MUTI-MONTI Technical manual Version 01/2017 Technical manual MUTI-MONTI Content Instructions for fixing P. 3 Chapter 1: Admissible loads in as well as P. 4 anchor characteristics for MMS-6 to MMS-16 1.1

More information

The cost-efficient fixing for flexible use in non-cracked concrete VERSIONS. zinc-plated steel stainless steel hot-dip galvanised steel

The cost-efficient fixing for flexible use in non-cracked concrete VERSIONS. zinc-plated steel stainless steel hot-dip galvanised steel The cost-efficient fixing for flexible use in non-cracked concrete VERSIONS APPROVALS zinc-plated steel stainless steel hot-dip galvanised steel BUILDING MATERIALS Approved for: Concrete C20/25 to C50/60,

More information

KINETICS Seismic Design Manual

KINETICS Seismic Design Manual KCAB Wedge Type Anchor Selection Guide For wedge type concrete anchors, the factor of safety is computed using the following equation. F.S. 1 = 1/[(T/T A ) (5/3) + (P/P A ) (5/3) ] (Eq. P1.3.1-1) Where:

More information

DIVISION: CONCRETE SECTION: CAST-IN CONCRETE ANCHORS SECTION: CONCRETE ANCHORS REPORT HOLDER: HALFEN GMBH

DIVISION: CONCRETE SECTION: CAST-IN CONCRETE ANCHORS SECTION: CONCRETE ANCHORS REPORT HOLDER: HALFEN GMBH 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-008 Reissued 04/207 This report is subject to renewal 04/208. DIVISION: 03 00 00

More information

1) INTRODUCTION 2) THE UNFAIR ADVANTAGE

1) INTRODUCTION 2) THE UNFAIR ADVANTAGE 1 1) INTRODUCTION 2) THE UNFAIR ADVANTAGE and Stingray earth anchors are driven tipping plate soil anchors for reaction of tensile loads. anchors have ultimate capacities up to 20 tons, and Stingray anchors

More information

Code Compliance Research Report CCRR-0145

Code Compliance Research Report CCRR-0145 Code Compliance Research Report CCRR-0145 Issue Date: 11-16-2009 Revision Date: 11-29-2018 Renewal Date: 11-18-2019 DIVISION: 05 - Metals Section: 05 50 00 Metal Fabrications Marshall Stamping Company

More information

VSL MINING & TUNNELING SYSTEMS VSL. mining and tunneling

VSL MINING & TUNNELING SYSTEMS VSL. mining and tunneling VSL MINING & TUNNELING SYSTEMS VSL mining and tunneling VSL Mining & Tunneling Bolt systems VSL offers three type of bolting system for the mining & Tunnelling industry VSL-S Solid Threaded bolts. Continuous

More information

Technical Manual. Stand 05/2011

Technical Manual. Stand 05/2011 MULTI-MONTI Technical Manual Stan5/2011 Technical Manual HECO-MULTI-MONTI Contents Instructions for fixing P. 3 Chapter 1 : Admissible loads in as well as P. 4 anchor-characteristics for MMS-6 to MMS-16

More information

Code Compliance Research Report CCRR-0145

Code Compliance Research Report CCRR-0145 Code Compliance Research Report CCRR-0145 Issued: 11-16-2009 Renewal Due: 11-18-2018 Revised: 11-28-2017 DIVISION: 05 - Metals Section: 05 50 00 Metal Fabrications MARSHALL STAMPING COMPANY 355 Glade Mills

More information

Significant Changes in the 2005 ACI Code, Including Changes Affecting Precast/Prestressed Concrete Part 2

Significant Changes in the 2005 ACI Code, Including Changes Affecting Precast/Prestressed Concrete Part 2 Significant Changes in the 2005 ACI Code, Including Changes Affecting Precast/Prestressed Concrete Part 2 S. K. Ghosh, Ph.D., FPCI President S. K. Ghosh Associates Inc. Palatine, Illinois Significant changes

More information

The following excerpt are pages from the North American Product Technical Guide, Volume 2: Anchor Fastening, Edition 17.

The following excerpt are pages from the North American Product Technical Guide, Volume 2: Anchor Fastening, Edition 17. The following exerpt are pages from the North Amerian Produt Tehnial Guide, Volume 2: Anhor Fastening, Edition 17. Please refer to the publiation in its entirety for omplete details on this produt inluding

More information

Introduction Introduction

Introduction Introduction Introduction Maritime International is a leading manufacturer of marine bollards and cleats worldwide. Our range of bollards and cleats is unsurpassed by any other manufacturer or supplier. Maritime can

More information

REPORT HOLDER: FRAMECAD LICENSING LTD. POST OFFICE BOX 1292 AUCKLAND 1140 NEW ZEALAND EVALUATION SUBJECT: COLD FORMED STEEL C SHAPES AND TRACKS

REPORT HOLDER: FRAMECAD LICENSING LTD. POST OFFICE BOX 1292 AUCKLAND 1140 NEW ZEALAND EVALUATION SUBJECT: COLD FORMED STEEL C SHAPES AND TRACKS 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2361 Reissued 05/2017 This report is subject to renewal 05/2019. DIVISION: 05 00

More information

SCOUT DECK ANCHOR 3 1/4" BONDING SCREW

SCOUT DECK ANCHOR 3 1/4 BONDING SCREW SCOUT DECK ANCHOR 16" 16" 1" X 4" ANCHOR BOLT (4) 10" 3 1/8" 5" 6" MIN COPPER WIRE TO ATTACH TO BONDING GRID 3 1/4" BONDING SCREW CONCRETE DECK SPECIFICATIONS: THE AQUA CREEK PRODUCTS' SCOUT DECK ANCHOR

More information

Operations and Instruction Manual Might Swivel Model # Concrete and Steel Anchorage Connector ANSI Z ,000 lbs / 44kn

Operations and Instruction Manual Might Swivel Model # Concrete and Steel Anchorage Connector ANSI Z ,000 lbs / 44kn Operations and Instruction Manual Might Swivel Model # 00238 Concrete and Steel Anchorage Connector ANSI Z359.1 10,000 lbs / 44kn Description: Zinc plated forged heat treated steel, Special design gives

More information

6.0 ENGINEERING. Build Anything Better. REPRINTED 2017

6.0 ENGINEERING. Build Anything Better.  REPRINTED 2017 6.0 ENGINEERING TABLE OF CONTENTS 6.1 U.S. ENGINEERING ANALYSIS REPORT... P. 6-3 BELOW-GRADE WALL REINFORCEMENT TABLES... P. 6-5 ABOVE-GRADE WALL REINFORCEMENT TABLES.. P. 6-21 LINTEL REINFORCEMENT TABLES...P.

More information

1.3 LIMITATIONS: The following application limitations must be recognized and considered before using this product:

1.3 LIMITATIONS: The following application limitations must be recognized and considered before using this product: 3965 Pepin Avenue Red Wing, MN 55066-1837 Toll Free: (800) 328-6146 Phone: (651) 388-8282 Fax: (651) 388-5065 www.protecta.com User Instruction Manual AJ720A Concrete Anchor This manual is intended to

More information

The first and only continuous tension holdown system.

The first and only continuous tension holdown system. The first and only continuous tension holdown system. CANADA LIMIT STATES EDITION FEBRUARY 2017 Earthbound Seismic and Wind Holdown Systems. The industry leader in hardware and design technology. FEATURES

More information

SECTION BUTTERFLY VALVES

SECTION BUTTERFLY VALVES SECTION 15112 BUTTERFLY VALVES PART 1 GENERAL 1.01 SUMMARY A. All butterfly valves shall be of the tight closing, rubber seated type and fully comply with the latest revision of AWWA Standard C504, Class

More information

TECHNICAL MANUAL. COPRA Anchoring Coupler. For Smart Bolted Connections

TECHNICAL MANUAL. COPRA Anchoring Coupler. For Smart Bolted Connections TECHNICAL MANUAL Anchoring Coupler For Smart Bolted Connections Version: PEIKKO GROUP 03/2017 Anchoring Coupler For bolted connections Multi-purpose anchoring system for all bolted connections Simplifi

More information

Benefits. caused by overloading Quick. tester. ons. Applicati HAP 1.15 HAP safety. shackle. After activation safety shackle.

Benefits. caused by overloading Quick. tester. ons. Applicati HAP 1.15 HAP safety. shackle. After activation safety shackle. HAP 1.15 Hoist Anchor Plate Benefits No limitation in load direction, hookk (shackle) can rotate and swivel, symmetric design of base plate withh 4 anchors Design fits application requirements of dynamic

More information

KERSPLASH POOL CLIMBING WALL INSTALLATION INSTRUCTIONS

KERSPLASH POOL CLIMBING WALL INSTALLATION INSTRUCTIONS TOLL FREE: 1-800-476-7366 VOICE 651-665-9131 FAX 651-665-9130 EMAIL: INFO@POOLCLIMBINGWALLS.COM EVERLAST CLIMBING 1335 MENDOTA HEIGHTS ROAD MENDOTA HEIGHTS, MN 55120 2012 EVERACTIVE BRANDS Congratulations!

More information

Research on Shear Test methods of bonded steel bolts

Research on Shear Test methods of bonded steel bolts Research on Shear Test methods of bonded steel bolts *Quan Xueyou 1), Li Xiongsong 2) and Luo Chujie 2) 1), 2) School of Civil Engineering, Chongqing University 1), 2) Key Laboratory of New Technology

More information

PRODUCT CARD WALL MOUNTED FIXED BASKETBALL CONSTRUCTION PROJECTION: FROM 1,00 TO 2,25 M

PRODUCT CARD WALL MOUNTED FIXED BASKETBALL CONSTRUCTION PROJECTION: FROM 1,00 TO 2,25 M PRODUCT CARD WALL MOUNTED FIXED BASKETBALL CONSTRUCTION PROJECTION: FROM 1,00 TO 2,25 M I. List of components... 2 II. Complimentary products... 2 III. Product description... 3 IV. Product Purpose... 3

More information

TYPE: LSF - LIFTING STUD FOOT ANCHOR DESCRIPTION: The design of the anchor means no additional reinforcement is required as the forces are transferred into the concrete from the design of the foot of the

More information

INTRODUCTION TABLE OF CONTENTS

INTRODUCTION TABLE OF CONTENTS 2 INTRODUCTION Thank you for choosing Servometer to design and manufacture your unique, new electrodeposited bellows for your particular application. The definitions, formulas and design parameters inside

More information

Moai Bike Rack Heavy Duty Submittal Sheet. Materials: 2.0 Schedule 40 Pipe (2.375 OD) Finishes: Capacity: Mount Options: Setbacks: 2 Bikes

Moai Bike Rack Heavy Duty Submittal Sheet. Materials: 2.0 Schedule 40 Pipe (2.375 OD) Finishes: Capacity: Mount Options: Setbacks: 2 Bikes Submittal Sheet Materials: 2.0 Schedule 40 Pipe (2.375 OD) Finishes: Galvanized An after fabrication hot dipped galvanized finish is available. Powder Coat Our powder coat finish assures a high level of

More information

OPERATION AND INSTRUCTION MANUAL Swivel Anchor Model: SWY100N

OPERATION AND INSTRUCTION MANUAL Swivel Anchor Model: SWY100N OPERATION AND INSTRUCTION MANUAL Swivel Anchor Model: SWY100N IMPORTANT!!! ALL PERSONS USING THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS. FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY OR DEATH.

More information

Made in the USA. For Fall Protection Only. SafeLok Part Description

Made in the USA. For Fall Protection Only. SafeLok Part Description Operations and Instruction Manual SafeLok Anchorage - Model # 4011 IM-0051 REV A Portable Concrete and Steel Anchorage Connector ANSI Z359.1-07 5,000 lbs / 22kn Made in the USA The 3/4 Fall Protection

More information

Originally Issued: 10/08/2010 Revised: 10/27/2017 Valid Through: 10/31/2018

Originally Issued: 10/08/2010 Revised: 10/27/2017 Valid Through: 10/31/2018 ITW BUILDING COMPONENTS GROUP INC. ITW ALPINE HANGERS AND ANCHORS CSI Section: 06 05 23 Wood, Plastic and Composite Fastenings 1.0 RECOGNITION ITW Alpine Hangers and Anchors recognized in this report has

More information

PRODUCT CARD WALL MOUNTED SIDE FOLDED BASKETBALL CONSTRUCTION PROJECTION: FROM 1,2 TO 2,45 M

PRODUCT CARD WALL MOUNTED SIDE FOLDED BASKETBALL CONSTRUCTION PROJECTION: FROM 1,2 TO 2,45 M PRODUCT CARD WALL MOUNTED SIDE FOLDED BASKETBALL CONSTRUCTION PROJECTION: FROM 1,2 TO 2,45 M I. List of components... 2 II. Complimentary products... 2 III. Product description... 3 IV. Product Purpose...

More information

FITNESS, SAFETY & MEDICAL SUPPLIES

FITNESS, SAFETY & MEDICAL SUPPLIES COMMERCIAL SERIES LIFTS TABLE OF CONTENTS 1. TRI-Point Anchor System 2. TRI-Point Paver Instruction Anchor Method 3. TRI-Point Retro-Fit Anchor System 4. TRI-Point Drop In Anchor System 5. Commercial Series

More information

Made in U.S.A. Narrow-U Bike Rack Heavy Duty Submittal Sheet. Materials: Finishes: Mount Options: Setbacks:

Made in U.S.A. Narrow-U Bike Rack Heavy Duty Submittal Sheet. Materials: Finishes: Mount Options: Setbacks: Submittal Sheet Materials: 2 Schedule 40 Steel Pipe (2.375 OD) Finishes: Galvanized An after fabrication hot dipped galvanized finish is available Powder Coat Our powder coat finish assures a high level

More information

BARRIER OFFSET 0" A 6" 6" A 12" 12" A 26" A 26" 3A OR 4A L OR S * ** L OR S L OR S

BARRIER OFFSET 0 A 6 6 A 12 12 A 26 A 26 3A OR 4A L OR S * ** L OR S L OR S ACCEPTABLE (TCB) TYPES AND ANCHORING DETAILS BASED ON UNDERLYING SURFACE TYPE AND BARRIER OFFSET FROM DROP-OFF BARRIER OFFSET UNDERLYING SURFACE 0" A 6" 6" A 12" 12" A 26" A 26" TCB TYPE DETAIL TCB TYPE

More information

Originally Issued: 10/08/2010 Revised: 10/30/2015 Valid Through: 10/31/2016

Originally Issued: 10/08/2010 Revised: 10/30/2015 Valid Through: 10/31/2016 EVALUATION SUBJECT: ITW ALPINE HANGERS AND ANCHORS REPORT HOLDER: ITW Building Components Group Inc. 13825 W. Business Center Dr. Unit A Lake Forest, IL 60045 (800) 521-9790 www.alpineitw.com CSI Division:

More information

Mechanical Stabilisation for Permanent Roads

Mechanical Stabilisation for Permanent Roads Mechanical Stabilisation for Permanent Roads Tim Oliver VP Global Applications Technology Tensar International toliver@tensar.co.uk Effect of geogrid on particle movement SmartRock Effect of geogrid on

More information

Reinforced Soil Retaining Walls-Design and Construction

Reinforced Soil Retaining Walls-Design and Construction Lecture 32 Reinforced Soil Retaining Walls-Design and Construction Prof. G L Sivakumar Babu Department of Civil Engineering Indian Institute of Science Bangalore 560012 Example calculation An 8 m high

More information

threaded rod Keystock Diamond Case Linear Shafting strapping seals tools

threaded rod Keystock Diamond Case Linear Shafting strapping seals tools threaded rod Keystock Diamond Case Linear Shafting strapping seals tools THREADED STEEL ROD... 19-2 KEY STOCK... 19-2 STEEL STRAPPING... 19-3 DIAMOND CASE SHAFTING Carbon (1060) Standard Sizes... 19-4

More information

SAFETY JOURNAL FOR GIPFEL WEDGE ROCK ANCHOR BOLTS

SAFETY JOURNAL FOR GIPFEL WEDGE ROCK ANCHOR BOLTS SAFETY JOURNAL FOR GIPFEL WEDGE ROCK ANCHOR BOLTS NOTE: Here we are only talking about the wedge type expansion bolts. How do rock anchors fail? A rock anchor assembly mainly comprises of a Hanger and

More information

THREADED ROD & ACCESSORIES. Superior strength, maximum versatility.

THREADED ROD & ACCESSORIES. Superior strength, maximum versatility. Superior strength, maximum versatility. GRTRBRO 12/2013 Threaded rod is used for general purpose fastening and installation. Used in any place that a long bolt is required, threaded rod can be cut to the

More information

Series 8500 Expansion Compensators. Catalog 674H

Series 8500 Expansion Compensators. Catalog 674H Series 8500 Expansion Compensators Catalog 674H 500 Laminated Bellows Expansion J Series 8500 on Joints Expansion Compensators Sizes 3/4" through 4" Threaded, welded, flanged and grooved steel pipe joints

More information

3/4 SafeClaw Anchorage Connectors

3/4 SafeClaw Anchorage Connectors Operations and Instruction Manual Model #4075 Portable Concrete Anchorage Connector ANSI Z359.1-07 5,000 lbs / 22kn OHSA 1910.66 & 1926.502 Effective: 01/2012 Expires: 01/2022 IM-0049 REVA 3/4 SafeClaw

More information

Installation and Operation Instruction Manual

Installation and Operation Instruction Manual Installation and Operation Instruction Manual Toggle Lok Anchor - Model #7442 Portable Concrete Anchorage Connector ANSI Z359.1 5,000 lbs / 22.24 kn FallTech, Inc 1306 Alameda Street Compton, CA 90221

More information

PRO-ROD TM COILED ROD. Reduce Maintenance Increase Production Enhance Profit

PRO-ROD TM COILED ROD. Reduce Maintenance Increase Production Enhance Profit PRO-ROD TM COILED ROD Reduce Maintenance Increase Production Enhance Profit DOVER ARTIFICIAL LIFT Elevating the Potential of Artificial Lift Production. Dover Artificial Lift, part of Dover Energy, offers

More information

Mini Channel & Fittings

Mini Channel & Fittings Our mini channels and fittings provide for an economical method of supporting light load requirements on a strut system. Channel Channels are cold formed on our modern rolling mills from 18 Ga. (1.2 mm)

More information

Continental Industries TRANSITION FITTINGS or FAX Visit

Continental Industries TRANSITION FITTINGS or FAX Visit Continental Industries TRANSITION FITTINGS 1-800-558-1373 or FAX 1-800-788-1668 Visit www.conind.com ABOUT US Our Company Continental Industries, headquartered in Tulsa, Oklahoma, was formed in 1958 and

More information

POP UP ANCHOR. Part Number Spectrum Lane ~ Missoula MT ~

POP UP ANCHOR. Part Number Spectrum Lane ~ Missoula MT ~ POP UP ANCHOR Part Number 153169 7100 Spectrum Lane ~ Missoula MT 59808 800.791.8056 ~ www.spectrumproducts.com You have purchased a Spectrum Products Pop Up Lane Rope Anchor. Providing the unit is installed

More information

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108 AWWA C504 COMPLIANT VALVES FROM 3 THRU 108 PO Box 411 Berwick PA 18603 800-247-VALV www.crispinvalve.com 500 SERIES: Sizes 3-20 Available The K-Flo 500 Series is a heavy-duty resilient seated butterfly

More information

New MacLean-Dixie 3-1/2 Strength Squared Pipe Piles/Anchors (Patent Pending) for Compression and Tension Applications

New MacLean-Dixie 3-1/2 Strength Squared Pipe Piles/Anchors (Patent Pending) for Compression and Tension Applications Page: 1 of 6 New MacLean-Dixie 3-1/2 Strength Squared Pipe Piles/Anchors (Patent Pending) for Compression and Tension Applications ICC AC358 Acceptance Criteria for Foundation Systems and Devices APPLICATION

More information

Hoses and Lances 20,000 PSI

Hoses and Lances 20,000 PSI Jetstream provides a full arrangement of hoses and flex lances for ultra high pressure waterblasting. The hoses and lances are designed to be durable and reliable for any 20,000 psi application. A large

More information

Declaration of Performance Number 1109-CPD-0079 According to Regulation EU No 305/2011

Declaration of Performance Number 1109-CPD-0079 According to Regulation EU No 305/2011 Item code: HXE01, HXE85, HXE02, HXE12, HXE03 Manufacturer: Tecfi S.p.A. - S.S. Appia, km 193-81050 Pastorano (CE), Italy Table 1 - Intended use Generic type: Metal anchor for use in concrete, concrete

More information

DIVISION: 06--WOOD AND PLASTICS SECTION: Wood, Plastic and Composite Fastenings

DIVISION: 06--WOOD AND PLASTICS SECTION: Wood, Plastic and Composite Fastenings DIVISION: 06--WOOD AND PLASTICS SECTION: 060523 -- Wood, Plastic and Composite Fastenings REPORT HOLDER: ITW BUILDING COMPONENTS GROUP, INC. 2400 LAKE ORANGE DRIVE, SUITE 150 ORLANDO, FLORIDA 32837 (800)

More information

OPERATION AND INSTRUCTION MANUAL

OPERATION AND INSTRUCTION MANUAL OPERATION AND INSTRUCTION MANUAL Swivel Anchor Model: SWS100N-316-CTS Patent US # 8,424,638 WARNING: ALL PERSONS USING THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS. FAILURE TO DO SO MAY RESULT

More information

Item 404 Driving Piling

Item 404 Driving Piling Item Driving Piling 1. DESCRIPTION Drive piling. 2. EQUIPMENT 2.1. Driving Equipment. Use power hammers for driving piling with specified bearing resistance. Use power hammers that comply with Table 1.

More information

Glass Steel, Inc. Fiberglass Composite Troughs

Glass Steel, Inc. Fiberglass Composite Troughs Glass Steel, Inc. Fiberglass Composite Troughs El Mira, CA Flat Bottom Curved Troughs Glass Steel, Inc. FIBERGLASS COMPOSITE TROUGHS Glass-Steel, Inc. manufactures a proprietary system of composite effluent

More information

OPERATION AND INSTRUCTION MANUAL Swivel Anchor Model: SWY100N

OPERATION AND INSTRUCTION MANUAL Swivel Anchor Model: SWY100N OPERATION AND INSTRUCTION MANUAL Swivel Anchor Model: SWY100N Patent # US 8,424,638 WARNING: ALL PERSONS USING THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS. FAILURE TO DO SO MAY RESULT IN SERIOUS

More information

Casing Spacer Technology Leaders

Casing Spacer Technology Leaders Casing Spacer Technology Leaders Benefit today. Save down the line. www.racispacers.com NORTH AMERICA Why Raci Raci has been the global leader in casing spacer technology since 1952. Our uniquely designed,

More information

pvc well casing & drop pipe

pvc well casing & drop pipe C e r t a i nte e d pvc well casing & drop pipe P V C We l l P r o d u c t s Sure Fit PVC well casing and drop pipe have gained broad acceptance since their introduction almost 40 years ago. Today, due

More information

STRESS ANALYSIS OF BICYCLE PADDLE AND OPTIMIZED BY FINITE ELEMENT METHOD. S. Abeygunasekara 1, T. M. M. Amarasekara 2

STRESS ANALYSIS OF BICYCLE PADDLE AND OPTIMIZED BY FINITE ELEMENT METHOD. S. Abeygunasekara 1, T. M. M. Amarasekara 2 - 96 - STRESS ANALYSIS OF BICYCLE PADDLE AND OPTIMIZED BY FINITE ELEMENT METHOD S. Abeygunasekara 1, T. M. M. Amarasekara 2 1 Faculty of Engineering & Technology, Colombo International Nautical Engineering

More information

New MacLean-Dixie 4-1/2 Strength Squared Pipe Piles/Anchors (Patent Pending) for Compression and Tension Applications

New MacLean-Dixie 4-1/2 Strength Squared Pipe Piles/Anchors (Patent Pending) for Compression and Tension Applications Page: 1 of 6 New MacLean-Dixie 4-1/2 Strength Squared Pipe Piles/Anchors (Patent Pending) for Compression and Tension Applications P45 Series 4-1/2 (O.D.) Schedule 40 Pipe Pile Torque Capacity (ft-lbs)

More information

A New Test Setup for Testing Polyethylene Tubes under Constant and Cyclic Internal Pressures

A New Test Setup for Testing Polyethylene Tubes under Constant and Cyclic Internal Pressures A New Test Setup for Testing Polyethylene Tubes under Constant and Cyclic Internal Pressures S. Vahidi, E. Schruba, Y. Sun, M. McCarthy, and Y. G. Hsuan Drexel University, Philadelphia, PA, USA Abstract

More information

OPERATION AND INSTRUCTION MANUAL

OPERATION AND INSTRUCTION MANUAL OPERATION AND INSTRUCTION MANUAL Dual Extension Swivel Anchor Model: SWD100N-036 WARNING: ALL PERSONS USING THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS. FAILURE TO DO SO MAY RESULT IN SERIOUS

More information

1 SafeClaw Anchorage Connectors

1 SafeClaw Anchorage Connectors Operations and Instruction Manual Model #4077 Portable Concrete Anchorage Connector ANSI Z359.1 10,000 lbs / 44kn OHSA 1910.66 & 1926.502 Effective: 01/2012 Expires: 01/2022 IM-0050 REVA 1 SafeClaw Anchorage

More information

OPERATION AND INSTRUCTION MANUAL Swivel Anchor Model: HD26248

OPERATION AND INSTRUCTION MANUAL Swivel Anchor Model: HD26248 OPERATION AND INSTRUCTION MANUAL Swivel Anchor Model: HD26248 IMPORTANT!!! ALL PERSONS USING THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS. FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY OR DEATH.

More information

SECTION SHOWER AND BATH ENCLOSURES. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

SECTION SHOWER AND BATH ENCLOSURES. Display hidden notes to specifier by using Tools / Options / View / Hidden Text. SECTION 10185 SHOWER AND BATH ENCLOSURES Display hidden notes to specifier by using Tools / Options / View / Hidden Text. PART 1 GENERAL 1.1 SECTION INCLUDES A. Bathtub wall enclosures. B. Shower wall

More information

1 Exam Prep. Questions and Answers

1 Exam Prep. Questions and Answers Part 1 1 Exam Prep Standard for Polyvinyl Chloride Pressure Pipe ANSI/AWWA C900-07 Questions and Answers 1. Which of the following statement is not a correct statement? A. A DR is the average O.D. divided

More information

Haynes 214 (UNS N07214)

Haynes 214 (UNS N07214) Haynes 214 (UNS N07214) Haynes 214 is a Nickel-Iron-Chromium-Aluminum alloy that offers elevated temperature oxidation resistance up to 1750oF. It is a wrought heat resistant alloy that is used in electronic

More information

Hardened Steel Washers

Hardened Steel Washers USS (Type A Wide) Flat Washers Hardened Steel Washers Grade 8 S.A.E. Dimensions American Standard Lbs. Per No./Pcs. Gauge M Pcs. Per Lb. 3/16 9/16 1/4 18 (3/64) 2.8 361 1/4 3/4 5/16 16 (1/16) 6.7 149 5/16

More information

Composite Pilings. For A Lasting Foundation

Composite Pilings. For A Lasting Foundation Composite Pilings For A Lasting Foundation Product Overview Fortress Pilings are fully composite piles comprised of structural fiberglass protected by a premium gel coat finish. Fortress Pilings outperform

More information

Utility Anchor System

Utility Anchor System Utility Anchor System The Dayton Superior Utility Anchor System is designed to economically simplify the lifting and handling of precast concrete elements. Its economics, ease of use and versatility will

More information

Bike-Shell Model 301P

Bike-Shell Model 301P Bike-Shell Model 301P NEW design, one piece FRP Composite bike locker NO ASSEMBLY required Specify the 300 Series lockers for the highest customer satisfaction from the no-assembly ready-touse delivery

More information

ISO 6804 INTERNATIONAL STANDARD. Rubber and plastics inlet hoses and hose assemblies for washing-machines and dishwashers Specification

ISO 6804 INTERNATIONAL STANDARD. Rubber and plastics inlet hoses and hose assemblies for washing-machines and dishwashers Specification INTERNATIONAL STANDARD ISO 6804 Third edition 2009-09-15 Rubber and plastics inlet hoses and hose assemblies for washing-machines and dishwashers Specification Tuyaux et flexibles en caoutchouc et en plastique

More information

Precision Liquid Settlement Array Manual

Precision Liquid Settlement Array Manual Precision Liquid Settlement Array Manual All efforts have been made to ensure the accuracy and completeness of the information contained in this document. RST Instruments Ltd reserves the right to change

More information

Surf Clear EVO Epoxy system for surfboards

Surf Clear EVO Epoxy system for surfboards Page 1 / 6 Surf Clear EVO Epoxy system for surfboards Sicomin Surf Clear EVO epoxy system is specially formulated for the manufacturing of surf boards. Surf Clear EVO is suitable for hand lay up of glass,

More information

INDUSTRIAS IBAIONDO, HYDROPNEUMATIC TANKS

INDUSTRIAS IBAIONDO, HYDROPNEUMATIC TANKS IBAIONDO, HYDROPNEUMATIC TANKS IBAIONDO, INTRODUCTION Hydropneumatic tanks are designed to be used in potable water supply installations as a part of the pressure booster set in order to ensure the adequate

More information

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company CIF A Tyco International Company 1 Foam Concentrate CIF 3% AFFF -UL Listed -UL Canada Listed 6% AFFF 6 parts AFFF concentrate to 94 parts water -UL Listed- Foam Liquid -UL Canada Listed 3% FLUOROPROTEIN

More information

PHOENIX, ARIZONA USA

PHOENIX, ARIZONA USA NEW PRODUCTS MODEL: US-AASS-80 DESCRIPTION: Cantilever Arm 80 MEETS OSHA & ANSI Z359.14 CLASS B 1-800-850-5914 PHOENIX, ARIZONA USA WWW.ULTRASAFEUSA.COM CANTILEVER ARM The Ultra-Safe cantilever arm has

More information