From: Commander, Carderock Division, Naval Surface Warfare Center, Philadelphia, PA To: Program Executive Officer, Ships (PMS 400D)

Size: px
Start display at page:

Download "From: Commander, Carderock Division, Naval Surface Warfare Center, Philadelphia, PA To: Program Executive Officer, Ships (PMS 400D)"

Transcription

1 9551 Ser 926/ May 2006 From: Commander, Carderock Division, Naval Surface Warfare Center, Philadelphia, PA To: Program Executive Officer, Ships (PMS 400D) Subj: SELECTIVE APPROVAL OF MONEL ¼ TO 1 SWAGELOK MECHANICALLY ATTACHED FITTINGS (MAF) IN COMPRESSED AIR SYSTEMS ON SURFACE SHIPS Ref: (a) Swagelok Company ltr of 25 January 2005, Re: Alloy 400/405 ¼ through 1 Swagelok Tube Fittings and ASTM F (b) Swagelok Company, Test Report, Alloy 400/405 Swagelok Tube Fitting Testing per ASTM F with 70/30 Copper-Nickel Tubing per MIL-T-16420K, 21 Jan 2005 (c) ASTM F , Standard Specification for Performance of Piping and Tubing Mechanically Attached Fittings (d) MIL-T-16420K, Military Specification, Tube, Copper-Nickel Alloy, Seamless and Welded, 14 April 1978 (e) MIL-STD-777E, Military Standard, Schedule of Piping, Valves, Fittings, and Associated Components for Naval Surface Ships, 7 Feb 1986 (f) Naval Ship s Technical Manual (NSTM), S9086-RK-STM-010/CH-505, Piping Systems, Revision 2 dated 1 Dec 2001 Encl: (1) Rationale for Selective Approval of Swagelok Tube Fittings for Shipboard Use, NSWCCD-SSES Code 926, May 2006 (2) Cross Reference of Categories and Groups for Compressed Air Systems 1. As requested by Program Executive Office Ships, PMS 400D, Naval Surface Warfare Center, Carderock Division, Ship Systems Engineering Station (NSWCCD-SSES) Code 926 has reviewed reference (a), a request for approval of Swagelok Company s Alloy 400/405 (Monel) ¼ through 1 OD Mechanically Attached Fittings. 2. Reference (a) forwarded reference (b), a report of testing conducted by Swagelok in accordance with reference (c). All testing was conducted on 70/30 Copper-Nickel (CuNi) tubing in accordance with reference (d), and rationale for extension of test results to apply to 90/10 CuNi tubing in accordance with reference (d) was provided by Swagelok. 3. Reference (e) specifies the Service Categories and Groups of non-nuclear piping systems on surface ships. The categories applicable to compressed air systems are J-1 through J-9. References (e) and (f) address fire hardened fittings and their applications.

2 Subj: SELECTIVE APPROVAL OF MONEL ¼ TO 1 SWAGELOK MECHANICALLY ATTACHED FITTINGS (MAF) IN COMPRESSED AIR SYSTEMS ON SURFACE SHIPS 4. The Alloy 400/405 (Monel) Swagelok Tube Fittings were determined to be in compliance with reference (c), Type IV (Grip-Type), Grade C, Class 8 (Class 10 for ¼ OD) and are approved for limited use on CuNi tubing in compressed air systems applications as outlined below. The use of 70/30 versus 90/10 CuNi tubing shall be as specified in reference (e) for each Compressed Air System category. Note that this approval is not applicable to Submarines, Nuclear Systems, or Nuclear Surface Ship Machinery Spaces. a. The Monel ¼ OD Swagelok Tube Fittings are approved for use in Compressed Air Systems categories J-4, J-7, and J-8 throughout the ship, including Fire Hazardous Spaces. b. The Monel ¼ OD Swagelok Tube Fittings are approved for use in Compressed Air Systems categories J-2 and J-3 in Non-Fire Hazardous Spaces only. These fittings are not approved for use in Fire Hazardous Spaces, or in any Category J-1 High Pressure Air application. c. The Monel 3/8 through 1 OD Swagelok Tube Fittings are approved for use in Compressed Air Systems categories J-2, J-3, J-4, J-7, and J-8 in Non-Fire Hazardous Spaces only. These fittings are not approved for use in Fire Hazardous Spaces, or in any Category J-1 High Pressure Air application. 7. Technical rationale for approval of the Swagelok Tube Fittings and details of the applications within the various compressed air system categories is provided in enclosure (1). 8. Care must be taken during construction and maintenance of piping systems to ensure that the different material fittings, including their components (i.e. nuts and ferrules), are only used on the proper tubing. Also, care must be taken not to mix components from different manufacturers of tubing fittings. 9. Note that there may be differences between the categories and groups delineated in reference (e) and a Project Peculiar Document (PPD) being used for new construction. Enclosure (2) is a cross reference table between reference (e) and PPD AT. 10. NSWCCD-SSES point of contact is Keith Grimes, Code 926, Commercial (215) , DSN or keith.grimes@navy.mil. Copy to: NAVSEA Washington, DC (Codes 05Z9, 05P4) 2 T. A. PEROTTI By direction

3 Subj: SELECTIVE APPROVAL OF MONEL ¼ TO 1 SWAGELOK MECHANICALLY ATTACHED FITTINGS (MAF) IN COMPRESSED AIR SYSTEMS ON SURFACE SHIPS (cont d) Swagelok Company Solon Road Solon, OH Attn: John Karkosiak 3

4 Rationale for Selective Approval of Swagelok Tube Fittings for Shipboard Use NSWCCD-SSES Code 926 May 2006 References: (a) ASTM F , Standard Specification for Performance of Piping and Tubing Mechanically Attached Fittings (b) Swagelok Company ltr of 25 January 2005, Re: Alloy 400/405 ¼ through 1 Swagelok Tube Fittings and ASTM F (c) Swagelok Company, Test Report, Alloy 400/405 Swagelok Tube Fitting Testing per ASTM F with 70/30 Copper-Nickel Tubing per MIL-T-16420K, 21 Jan 2005 (d) MIL-T-16420K, Military Specification, Tube, Copper-Nickel Alloy, Seamless and Welded, 14 April 1978 (e) Swagelok Company ltr of 7 April 2006, Re: Approval of Swagelok, ¼ to 1 OD, 3750 PSIG and 6000 PSIG, Monel, Mechanically Attached Fittings (MAF), Non-Fire Hardened Applications, Surface Ships Only (f) Swagelok Company of 7 April 2006, Re: Supplemental Information on Monel Tube Fittings (g) MIL-STD-777E, Military Standard, Schedule of Piping, Valves, Fittings, and Associated Components for Naval Surface Ships, 7 Feb 1986 (h) NSWCCD-SSES ltr 9165 Ser 9234/056 dated 29 Nov 2005 (i) Naval Ship s Technical Manual (NSTM), S9086-RK-STM-010/CH-505, Piping Systems, Revision 2 dated 1 Dec 2001 Background: Reference (a) provides specifications for material selection and testing of piping and tubing Mechanically Attached Fittings (MAFs). Type IV MAFs are described in reference (a) as Grip-Type (Separable). Material Grade C refers to Nickel-Copper (Monel) fittings. The Class of a MAF refers to its maximum operating pressure. Class 8 is 3,750 psi maximum; Class 10 is 6,000 psi maximum. Swagelok Company has interest in obtaining approval for shipboard use of their Alloy 400/405 (Monel) Tube Fittings, which were designed to be in compliance with reference (a), Type IV, Grade C, Class 8 (Class 10 for ¼ OD). To that end, Swagelok Company performed testing meeting the requirements of reference (a). Reference (b) forwarded a test report, reference (c), for review and approval. Testing was accomplished using Monel fittings on 70/30 Copper-Nickel (CuNi) tubing in accordance with reference (d). Extension of test results for approval for using Monel fittings on 90/10 CuNi tubing, in accordance reference (d), was also requested. References (e) and (f) provided engineering rationale to support extension of the test results. Discussion: Paragraph 5 of reference (g) specifies the Service Categories and Groups of non-nuclear piping systems on surface ships. The categories applicable to compressed air systems are provided in Table 1. Enclosure (1)

5 Table 1 Service Categories and Groups for Compressed Air Systems Category/ Group Medium/Service Max. Pressure Max. Temperature J-1 Air, Nitrogen and Helium 6000 psig 150 F J-2 Air, Nitrogen and Helium 3300 psig 150 F J-3 Air and Nitrogen 600 psig 150 F J-4 Air and Nitrogen 200 psig 150 F J-5 Air, Aircraft, Starting and Cooling, Bleed-off and 20.2 psi Absolute 150 psig 550 F System J-6 Air, Aircraft, Starting and Cooling, Main System 150 psig 450 F J-7 Air, Prairie-Masker, Gas Turbine Starting, Sewage Aerating 100 psig 600 F J-8 Air, Deballast 50 psig 400 F J-9 Gas Turbine Bleed Air System 250 psig 950 F Reference (b) requested General Approval for the use of the Monel fittings in numerous fluid systems utilizing 70/30 and 90/10 CuNi tubing. Via reference (h), Naval Surface Warfare Center, Carderock Division, Ship Systems Engineering Station (NSWCCD- SSES) Code 9234 approved the fittings for use in seawater systems (Categories D-1, D-2, and D-3). Reference (b) further requests Selective Approval for the use of the Monel fittings in numerous other fluid systems, including Compressed Air Systems (Categories J-1, J-2, J- 3, J-4, J-7 and J-8). Fire hardened fitting requirements and applications are addressed in reference (g) paragraph and reference (i) paragraph Fire hardened fittings are required in Fire Hazardous Spaces for Category J-2, J-3, J-4, J-7, and J-8 Air Systems with Copper and CuNi Piping. Fire hardened fittings are required throughout the ship in all J-1 Air Systems, and J-2 through J-7 and J-9 Air Systems with Steel and CRES piping. Findings: NSWCCD-SSES Code 9214 has reviewed the information provided in references (b) and (c) and found the testing methods to be satisfactory and in compliance with reference (a). For the 3/8 to 1 OD tube fittings, testing was accomplished to qualify for operating pressures up to 3750 psig (Class 8). For the ¼ OD tube fitting, testing was accomplished to qualify for operating pressures up to 6000 psig (Class 10). The Alloy 400/405 (Monel) ¼ OD Swagelok Tube Fittings were determined to be in compliance with reference (a) Type IV, Grade C, up to Class 10 when used on 70/30 CuNi and 90/10 CuNi tubing. The ¼ OD fitting also passed the supplemental Fire Test 2

6 in accordance with reference (a) up to 500 psig, qualifying the use of the Monel ¼ OD Swagelok Tube Fittings for use in systems that have operating pressures below 500 psig, use CuNi tubing, and require fire hardened fittings as defined by references (g) and (i). The ¼ OD fittings are not qualified for use in applications that have operating pressures above 500 psig and require fire hardened fittings as defined by references (g) and (i). The Alloy 400/405 (Monel) 3/8 through 1 OD Swagelok Tube Fittings were determined to be in compliance with reference (a) Type IV, Grade C, up to Class 8 when used on 70/30 and 90/10 CuNi tubing. These sizes of fittings did not pass the supplemental Fire Test in accordance with reference (a). Therefore the Monel 3/8 through 1 OD Swagelok Tube Fittings are not qualified for use in systems with CuNi tubing that require fire hardened fittings as defined by references (g) and (i). Table 2 provides a summary of piping materials allowed in the various categories of Compressed Air Systems per reference (g). It also summarizes the applicability of Swagelok Type IV MAFs to these piping systems. According to reference (i) Table , similar stainless steel Swagelok Type IV, Class 8, Grade B MAFs have previously been granted selective approval for use on stainless steel piping. Their applicability to Compressed Air Systems is shown in the top section of Table 2. All other sections of Table 2 are referring to the Monel Swagelok Tube Fittings under review. Conclusions/Recommendations: The Alloy 400/405 (Monel) ¼ OD Swagelok Tube Fittings are approved for use in Compressed Air Systems categories J-4, J-7, and J-8 throughout the ship, including Fire Hazardous Spaces. The Alloy 400/405 (Monel) ¼ OD Swagelok Tube Fittings are approved for use in Compressed Air Systems categories J-2 and J-3 in Non-Fire Hazardous Spaces only. These fittings are not approved for use in Fire Hazardous Spaces, or in any Category J-1 High Pressure Air application. The Alloy 400/405 (Monel) 3/8 through 1 OD Swagelok Tube Fittings are approved for use in Compressed Air Systems categories J-2, J-3, J-4, J-7, and J-8 in Non-Fire Hazardous Spaces only. These fittings are not approved for use in Fire Hazardous Spaces, or in any Category J-1 High Pressure Air application. It is important to note that these approvals, and the approvals previously granted for stainless steel Swagelok Tube Fittings, are specific to the tubing material they are to be used on. The stainless steel Swagelok Tube Fittings are only approved for use on stainless steel tubing as delineated in reference (i). Furthermore, the Monel Swagelok Tube Fittings are only approved for use on reference (d) 70/30 and 90/10 CuNi tubing. Care must be taken during construction and maintenance of piping systems to ensure that the different material fittings, including their components (i.e. nuts and ferrules), are only used on the proper tubing. Also, care must be taken not to mix components from different manufacturers of tubing fittings. NSWCCD-SSES Code 926 POC is Keith Grimes,

7 Table 2 - Type IV MAFs in Compressed Air Systems CRES COMPRESSED AIR SYSTEM CATEGORY AND GROUP J-1 J-2 J-3 J-4 J-5 J-6 J-7 J-8 J-9 1/4" OD Not Approved 1 Not Approved 1 Not Approved 1 Not Approved 1 N/A 3 Not Approved 1 Not Approved 1 N/A 3 Not Approved 1 3/8" OD Not Approved 1 Not Approved 1 Not Approved 1 Not Approved 1 N/A 3 Not Approved 1 Not Approved 1 N/A 3 Not Approved 1 1/2" OD Not Approved 1 Not Approved 1 Not Approved 1 Not Approved 1 N/A 3 Not Approved 1 Not Approved 1 N/A 3 Not Approved 1 5/8" OD Approved 2 Approved 2 Approved 2 Approved 2 N/A 3 Approved 2 Approved 2 N/A 3 Approved 2 3/4" OD Approved 2 Approved 2 Approved 2 Approved 2 N/A 3 Approved 2 Approved 2 N/A 3 Approved 2 1" OD Approved 2 Approved 2 Approved 2 Approved 2 N/A 3 Approved 2 Approved 2 N/A 3 Approved 2 Cres Fittings 70/30 CuNi 1/4" OD Not Approved 4 Partial Approval 6 Partial Approval 6 Approved 7 N/A 3 N/A 3 Approved 7 N/A 3 N/A 3 3/8" OD Not Approved 5 Partial Approval 8 Partial Approval 8 Partial Approval 8 N/A 3 N/A 3 Partial Approval 8 N/A 3 N/A 3 1/2" OD Not Approved 5 Partial Approval 8 Partial Approval 8 Partial Approval 8 N/A 3 N/A 3 Partial Approval 8 N/A 3 N/A 3 5/8" OD Not Approved 5 Partial Approval 8 Partial Approval 8 Partial Approval 8 N/A 3 N/A 3 Partial Approval 8 N/A 3 N/A 3 3/4" OD Not Approved 5 Partial Approval 8 Partial Approval 8 Partial Approval 8 N/A 3 N/A 3 Partial Approval 8 N/A 3 N/A 3 1" OD Not Approved 5 Partial Approval 8 Partial Approval 8 Partial Approval 8 N/A 3 N/A 3 Partial Approval 8 N/A 3 N/A 3 PIPING MATERIAL 90/10 CuNi Copper 1/4" OD N/A 3 N/A 3 N/A 3 Approved 7,9 N/A 3 N/A 3 Approved 7,9 Approved 7,9 N/A 3 3/8" OD N/A 3 N/A 3 N/A 3 Partial Approval 8,9 N/A 3 N/A 3 Partial Approval 8,9 Partial Approval 8,9 N/A 3 1/2" OD N/A 3 N/A 3 N/A 3 Partial Approval 8,9 N/A 3 N/A 3 Partial Approval 8,9 Partial Approval 8,9 N/A 3 5/8" OD N/A 3 N/A 3 N/A 3 Partial Approval 8,9 N/A 3 N/A 3 Partial Approval 8,9 Partial Approval 8,9 N/A 3 3/4" OD N/A 3 N/A 3 N/A 3 Partial Approval 8,9 N/A 3 N/A 3 Partial Approval 8,9 Partial Approval 8,9 N/A 3 1" OD N/A 3 N/A 3 N/A 3 Partial Approval 8,9 N/A 3 N/A 3 Partial Approval 8,9 Partial Approval 8,9 N/A 3 1/4" OD N/A 3 Not Tested 10 Not Tested 10 Not Tested 10 N/A 3 N/A 3 Not Tested 10 N/A 3 N/A 3 3/8" OD N/A 3 Not Tested 10 Not Tested 10 Not Tested 10 N/A 3 N/A 3 Not Tested 10 N/A 3 N/A 3 1/2" OD N/A 3 Not Tested 10 Not Tested 10 Not Tested 10 N/A 3 N/A 3 Not Tested 10 N/A 3 N/A 3 5/8" OD N/A 3 Not Tested 10 Not Tested 10 Not Tested 10 N/A 3 N/A 3 Not Tested 10 N/A 3 N/A 3 3/4" OD N/A 3 Not Tested 10 Not Tested 10 Not Tested 10 N/A 3 N/A 3 Not Tested 10 N/A 3 N/A 3 1" OD N/A 3 Not Tested 10 Not Tested 10 Not Tested 10 N/A 3 N/A 3 Not Tested 10 N/A 3 N/A 3 Monel Fittings Glass Reinforced Plastic (GRP) 1/4" OD N/A 3 N/A 3 N/A 3 Not Tested 10 N/A 3 N/A 3 N/A 3 N/A 3 N/A 3 3/8" OD N/A 3 N/A 3 N/A 3 Not Tested 10 N/A 3 N/A 3 N/A 3 N/A 3 N/A 3 1/2" OD N/A 3 N/A 3 N/A 3 Not Tested 10 N/A 3 N/A 3 N/A 3 N/A 3 N/A 3 5/8" OD N/A 3 N/A 3 N/A 3 Not Tested 10 N/A 3 N/A 3 N/A 3 N/A 3 N/A 3 3/4" OD N/A 3 N/A 3 N/A 3 Not Tested 10 N/A 3 N/A 3 N/A 3 N/A 3 N/A 3 1" OD N/A 3 N/A 3 N/A 3 Not Tested 10 N/A 3 N/A 3 N/A 3 N/A 3 N/A 3 Carbon Steel 1/4" OD N/A 3 N/A 3 N/A 3 N/A 3 Not Tested 10 N/A 3 N/A 3 N/A 3 N/A 3 3/8" OD N/A 3 N/A 3 N/A 3 N/A 3 Not Tested 10 N/A 3 N/A 3 N/A 3 N/A 3 1/2" OD N/A 3 N/A 3 N/A 3 N/A 3 Not Tested 10 N/A 3 N/A 3 N/A 3 N/A 3 5/8" OD N/A 3 N/A 3 N/A 3 N/A 3 Not Tested 10 N/A 3 N/A 3 N/A 3 N/A 3 3/4" OD N/A 3 N/A 3 N/A 3 N/A 3 Not Tested 10 N/A 3 N/A 3 N/A 3 N/A 3 1" OD N/A 3 N/A 3 N/A 3 N/A 3 Not Tested 10 N/A 3 N/A 3 N/A 3 N/A 3 Note 1: MIL-STD-777E Requires Fire Hardened Fittings in this System throughout the entire ship when using CRES Piping. CRES fittings of this size were previously reviewed and are not approved for fire hardened fitting applications per NSTM Chap 505. Note 2: MIL-STD-777E Requires Fire Hardened Fittings in this System throughout the entire ship when using CRES Piping. CRES fittings of this size were previously approved for fire hardened fitting applications per NSTM Chap 505. Note 3: MIL-STD-777E does not allow this material of piping to be used in this category of System. Note 4: MIL-STD-777E Requires Fire Hardened Fittings in this System throughout the entire ship. This size Monel fitting did not pass the Fire Test per ASTM F1387 for pressures over 500 psig. This size Monel fitting is not approved for use in Category J-1 Systems. Note 5: MIL-STD-777E Requires Fire Hardened Fittings in this System throughout the entire ship. This size Monel fitting did not pass the Fire Test per ASTM F1387. This size Monel fitting is not approved for use in Category J- 1 Systems. Note 6: MIL-STD-777E Requires Fire Hardened Fittings in this System in Fire Hazardous Spaces only. This size Monel fitting did not pass the Fire Test per ASTM F1387 for pressures over 500 psig. This size Monel fitting is approved for use in this category System on this material of tubing in Non-Fire Hazardous Spaces only. Note 7: Swagelok conducted testing per ASTM F1387 for qualification of their Alloy 400/R-405 (Monel) Fittings for use on CuNi Tubing. Testing conducted meets the all requirements of NSTM Chap 505 and MIL-STD-777E for this category System. The 1/4" OD Monel fittings are approved for use in this category System on this material of tubing throughout the entire ship. Note 8: MIL-STD-777E Requires Fire Hardened Fittings in this System in Fire Hazardous Spaces only. This size Monel fitting did not pass the Fire Test per ASTM F1387. This size Monel fitting is approved for use in this category System on this material of tubing in Non-Fire Hazardous Spaces only. Note 9: All testing was accomplished using Monel fittings on 70/30 CuNi tubing. Approval was requested for use of the Monel fittings on 90/10 CuNi tubing as well, and technical rationale was provided to support the extension of the test results. Note 10: All testing was accomplished using Monel fittings on 70/30 CuNi tubing. Approval was not requested for use of Monel fittings on this material of piping, therefore no approval is granted. 4

8 Cross Reference of Categories and Groups for Compressed Air Systems Category/ Group MIL-STD-777 Medium/Service Max. Pressure Max. Temperature PPD AT Medium/Service Category/ Group J-1 Air, Nitrogen and Helium 6000 psig 150 F Air (for DDG 82 & Follow) J-1 J-2 Air, Nitrogen and Helium 3300 psig 150 F Air and Nitrogen J-2 J-3 Air and Nitrogen 600 psig 150 F Air and Nitrogen J-4 N/A N/A 150 psig 150 F J-4 Air and Nitrogen 200 psig 150 F J-5 J-6 J-7 Air, Aircraft, Starting and Cooling, Bleed-off and 20.2 psi Absolute System Air, Aircraft, Starting and Cooling, Main System Air, Prairie-Masker, Gas Turbine Starting, Sewage Aerating Air and Nitrogen (for DDG 51 Only) Air and Nitrogen (for DDG 52 & Follow) 150 psig 550 F N/A N/A 150 psig 450 F N/A N/A 100 psig 600 F Air: Prairie, Gas Turbine Starting J-8 J-8 Air, Deballast 50 psig 400 F N/A N/A Air: Gas Turbine Bleed, Anti-icing (for DDG 51 & 52 & Follow, follow yard hulls only) J-10 J-9 Gas Turbine Bleed Air System 250 psig 950 F Air: Prairie, Gas Turbine Starting (for DDG 53 & Follow, lead yard hulls only) N/A N/A ATM 150 F Air: Air Compressor Intake J-11 J-5 J-5 J-10 Enclosure (2)

NAVSEA STANDARD ITEM. 2.2 T9074-AS-GIB-010/271, Requirements for Nondestructive Testing Methods

NAVSEA STANDARD ITEM. 2.2 T9074-AS-GIB-010/271, Requirements for Nondestructive Testing Methods NAVSEA STANDARD ITEM ITEM NO: 009-53 DATE: 29 JUL 2011 CATEGORY: II 1. SCOPE: 1.1 Title: Bolted Bonnet Steam Valve; repair (shop) 2. REFERENCES: 2.1 S9086-CJ-STM-010/CH-075, Fasteners 2.2 T9074-AS-GIB-010/271,

More information

MSC Guidelines for Refrigeration Machinery

MSC Guidelines for Refrigeration Machinery Procedure Number E1-32 Revision Date: 07/27/10 S. J. Kelly, CDR, Chief of Engineering Division References: a. 46 CFR Part 56.50-105 Low Temperature Piping b. 46 CFR Part 58.20 Refrigeration Machinery c.

More information

PERFORMANCE SPECIFICATION PROPELLANT, HYDROGEN

PERFORMANCE SPECIFICATION PROPELLANT, HYDROGEN METRIC 17 May 2013 SUPERSEDING MIL-PRF-27201D 07 February 2007 PERFORMANCE SPECIFICATION PROPELLANT, HYDROGEN This specification is approved for use by all Departments and Agencies of the Department of

More information

NAVSEA STANDARD ITEM. 1.1 Title: Authorization, Control, Isolation, Blanking, Tagging, and Cleanliness; accomplish

NAVSEA STANDARD ITEM. 1.1 Title: Authorization, Control, Isolation, Blanking, Tagging, and Cleanliness; accomplish NAVSEA STANDARD ITEM ITEM NO: 009-24 DATE: 18 NOV 2016 CATEGORY: I 1. SCOPE: 1.1 Title: Authorization, Control, Isolation, Blanking, Tagging, and Cleanliness; accomplish 2. REFERENCES: 2.1 Standard Items

More information

MILITARY STANDARD INTERFACE STANDARD FOR SHIPBOARD SYSTEMS SECTION 106 COMPRESSED AIR SERVICE FOR SURFACE SHIPS

MILITARY STANDARD INTERFACE STANDARD FOR SHIPBOARD SYSTEMS SECTION 106 COMPRESSED AIR SERVICE FOR SURFACE SHIPS SUPERSEDING SECTION 106A 19 April 1973 (See 9.2) MILITARY STANDARD INTERFACE STANDARD FOR SHIPBOARD SYSTEMS SECTION 106 COMPRESSED AIR SERVICE FOR SURFACE SHIPS AMSC N/A FSC 1990 DISTRIBUTION STATEMENT

More information

ENGINEERING TECHNICAL REPORT

ENGINEERING TECHNICAL REPORT SSP DUOLOK FITTINGS ON 1.000 x 0.139 WALL 316SS TUBING ENGINEERING TECHNICAL REPORT SSP 8250 Boyle Parkway Twinsburg, Ohio 44087 U.S.A. mysspusa.com 1.330.425.4250 1 TABLE OF CONTENTS 1.0 Introduction

More information

PERFORMANCE SPECIFICATION PROPELLANT PRESSURIZING AGENT, ARGON

PERFORMANCE SPECIFICATION PROPELLANT PRESSURIZING AGENT, ARGON METRIC 07 August 2013 SUPERSEDING MIL-PRF-27415B 08 February 2007 PERFORMANCE SPECIFICATION PROPELLANT PRESSURIZING AGENT, ARGON Comments, suggestions, or questions on this document should be addressed

More information

SG TF. Q = 963 Cv (P1 - P2)(P1 + P2) TECHNICAL INFORMATION. Flow Q (GPM)

SG TF. Q = 963 Cv (P1 - P2)(P1 + P2) TECHNICAL INFORMATION. Flow Q (GPM) TECHNICAL INFORMATION BuTech designs all pressure-containing equipment to meet or exceed the applicable requirements of Section VIII, Division1 or Division 2 of the ASME Boiler and Pressure Vessel Code

More information

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM ASSE STANDARD #1003 - REVISED: 2009 Water Pressure Reducing Valves for Domestic Water Distribution Systems MANUFACTURER: CONTACT

More information

ASYBCO 90 O ELBOW LONG RADIUS O.D. I.D.

ASYBCO 90 O ELBOW LONG RADIUS O.D. I.D. 90 O ELBOW LONG RADIUS Standard weight Extra strong Schedule 160 Double extra strong ASTM A-234 ASME / ANSI B16.9 Carbon and ferritic alloy steel Produced from X-rayed, stress-relieve welded pipe. Welds

More information

East Building, PHH-30 U.S. Department New Jersey Avenue S.E. of Transportation Washington, D.C DOT-SP (TENTH REVISION)

East Building, PHH-30 U.S. Department New Jersey Avenue S.E. of Transportation Washington, D.C DOT-SP (TENTH REVISION) East Building, PHH-30 U.S. Department 1200 New Jersey Avenue S.E. of Transportation Washington, D.C. 20590 Pipeline and Hazardous Materials Safety Administration DOT-SP 11025 (TENTH REVISION) EXPIRATION

More information

COMPRESSION TUBE FITTINGS

COMPRESSION TUBE FITTINGS COMPRESSION TUBE FITTINGS 1/16 THROUGH 2 2 MM THROUGH 50 MM LET-LOK TUBE FITTINGS DESCRIPTION The HAM-LET GROUP has produced high quality tube and pipe fittings in various materials for high pressure applications

More information

MLS Series Liquid Level Switches. Installation and Operations Manual Section 15

MLS Series Liquid Level Switches. Installation and Operations Manual Section 15 MLS Series Liquid Level Switches Installation and Operations Manual 00-02-0730 2012-11-11 Section 15 In order to consistently bring you the highest quality full featured products, we reserve the right

More information

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000 Hoffman Specialty Regulators Regulators Pressure and/or Temperature Operated Regulators Series 2000 The Hoffman Specialty Series 2000 consists of main valves, pilot valves, wells and hardware kits. They

More information

NAVSEA STANDARD ITEM. 2.2 S0600-AA-PRO-160/CH-16, Underwater Ship Husbandry Manual, Cofferdams

NAVSEA STANDARD ITEM. 2.2 S0600-AA-PRO-160/CH-16, Underwater Ship Husbandry Manual, Cofferdams NAVSEA STANDARD ITEM ITEM NO: 009-77 DATE: 18 NOV 016 CATEGORY: II 1. SCOPE: 1.1 Title: Cofferdam Installation; accomplish. REFERENCES:.1 Standard Items. S0600-AA-PRO-160/CH-16, Underwater Ship Husbandry

More information

DETAIL SPECIFICATION VALVES, ANGLE, PRESSURE RELIEF, NAVAL SHIPBOARD, FOR STEAM SERVICE

DETAIL SPECIFICATION VALVES, ANGLE, PRESSURE RELIEF, NAVAL SHIPBOARD, FOR STEAM SERVICE INCH-POUND 7 December 2016 SUPERSEDING MIL-V-20065D(SHIPS) 8 June 1967 DETAIL SPECIFICATION VALVES, ANGLE, PRESSURE RELIEF, NAVAL SHIPBOARD, FOR STEAM SERVICE This specification is approved for use by

More information

2.2 S0600-AA-PRO-160/CH-16, Underwater Ship Husbandry Manual, Cofferdams

2.2 S0600-AA-PRO-160/CH-16, Underwater Ship Husbandry Manual, Cofferdams NAVSEA STANDARD ITEM FY-0 ITEM NO: 009-77 DATE: 0 AUG 2008 CATEGORY: I. SCOPE:. Title: Cofferdam Requirements; accomplish 2. REFERENCES: 2. Standard Items 2.2 S0600-AA-PRO-60/CH-6, Underwater Ship Husbandry

More information

Continental Industries STEEL SERVICE TEES or FAX Visit

Continental Industries STEEL SERVICE TEES or FAX Visit Continental Industries STEEL SERVICE TEES 1-800-558-1373 or FAX 1-800-788-1668 Visit www.conind.com ABOUT US Our Company Continental Industries, headquartered in Tulsa, Oklahoma, was formed in 1958 and

More information

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108 AWWA C504 COMPLIANT VALVES FROM 3 THRU 108 PO Box 411 Berwick PA 18603 800-247-VALV www.crispinvalve.com 500 SERIES: Sizes 3-20 Available The K-Flo 500 Series is a heavy-duty resilient seated butterfly

More information

COMPRESSION TUBE FITTINGS

COMPRESSION TUBE FITTINGS COMPRESSION TUBE FITTINGS 1/16 THROUGH 2 2 MM THROUGH 50 MM LET-LOK TUBE FITTINGS DESCRIPTION The HAM-LET GROUP has produced high quality tube and pipe LET-LOK HOW DOES IT WORK? A HAM-LET has gained an

More information

COMPONENTS MANUFACTURING

COMPONENTS MANUFACTURING COMPONENTS MANUFACTURING ASSEMBLY TESTING Manifolds Valex Manifolds PCW, CFOS, UHP Configurations with ball valve, diaphragm valve & bellows valve options Main run lengths up to 24 feet & 12 inch in diameter

More information

DOT-SP 8391 (FIFTHTEENTH REVISION) EXPIRATION DATE: (FOR RENEWAL, SEE 49 CFR )

DOT-SP 8391 (FIFTHTEENTH REVISION) EXPIRATION DATE: (FOR RENEWAL, SEE 49 CFR ) U.S. Department East Building, PHH 30 of Transportation 1200 New Jersey Avenue, Southeast Washington, Pipeline and Hazardous Materials Safety Administration D.C. 20590 DOT-SP 8391 (FIFTHTEENTH REVISION)

More information

SECTION BUTTERFLY VALVES

SECTION BUTTERFLY VALVES SECTION 15112 BUTTERFLY VALVES PART 1 GENERAL 1.01 SUMMARY A. All butterfly valves shall be of the tight closing, rubber seated type and fully comply with the latest revision of AWWA Standard C504, Class

More information

Product Test Report F.A. Lennon Drive December 2015 Solon, Ohio U.S.A. Page 1 of 7. Valve Series Description Test Pressure Test Qty.

Product Test Report F.A. Lennon Drive December 2015 Solon, Ohio U.S.A. Page 1 of 7. Valve Series Description Test Pressure Test Qty. Product Report Solon, Ohio 44139 U.S.A. Page 1 of 7 TITLE Fugitive and Seat Leakage Performance Type of Swagelok VB05 Block and Bleed Process Interface Valves Witnessed by a Third Party PRODUCT TESTED

More information

DESIGN DATA. Dry 105a. September 5, 2008

DESIGN DATA. Dry 105a. September 5, 2008 September 5, 2008 Dry 105a 1. Description Dry and Preaction Systems require a dependable source of clean dry air under the proper pressure. The air supply must be adequate to restore normal air pressure

More information

HYDROGEN STANDARDIZATION INTERIM REPORT For

HYDROGEN STANDARDIZATION INTERIM REPORT For STP/PT-003 Designator: Meta Bold 24/26 Revision Note: Meta Black 14/16 HYDROGEN STANDARDIZATION INTERIM REPORT For Tanks, Piping, and Pipelines Date of Issuance: June 6, 2005 This report was prepared as

More information

High-Purity. Ball Valves

High-Purity. Ball Valves High-Purity s Components MANUFACTURING ASSEMBLY TESTING HP High-Purity s CFOS Applications Cost-effective systems where cleaning for oxygen-grade services are required, such as: Clean-Dry Air (CDA), Oil-Free

More information

MSC Guidelines for Compressed Air Systems

MSC Guidelines for Compressed Air Systems Procedure Number: E1-04 Revision Date: 12/16/2013 References: a. 46 CFR 54 Pressure Vessels (Subchapter F) P. W. Gooding, CDR, Chief, Engineering Division b. 46 CFR 56 Piping Systems & Appurtenances (Subchapter

More information

1 Exam Prep NFPA 99 Health Care Facilities Questions and Answers (Plumbing Contractor)

1 Exam Prep NFPA 99 Health Care Facilities Questions and Answers (Plumbing Contractor) 1 Exam Prep NFPA 99 Health Care Facilities Questions and Answers (Plumbing Contractor) 1. According to NFPA 99, SCFM is an acronym for. a) Surface Conditions at Fahrenheit Mercury b) Standard Conditions

More information

EXPIRATION DATE: January 31, 2015

EXPIRATION DATE: January 31, 2015 U.S. Department East Building, PHH 30 of Transportation 1200 New Jersey Avenue, Southeast Pipeline and Hazardous Materials Safety Administration DOT-SP 7235 (TWENTY-THIRD REVISION) Washington, D.C. 20590

More information

6200E Installation Requirements

6200E Installation Requirements Requirements When purchasing a standalone 6200E unit with the calibrator, the analyzer will be supplied as three 19 rack mount units. Analyzer Converter Calibrator Included with the unit are two lengths

More information

Model Series 62 Constant Differential Relay

Model Series 62 Constant Differential Relay Siemens Industry, Inc. INSTALLATION AND SERVICE INSTRUCTION INTRODUCTION Model Series 62 Constant Differential Relay Rev 11 March 2011 Supersedes Rev 10 The Constant Differential Relay maintains a constant

More information

ACCU-PULSE Installation and Operation Instructions

ACCU-PULSE Installation and Operation Instructions ACCU-PULSE Installation and Operation Instructions Pump Discharge Installation: Chargeable Models Step 1: Mounting Position Mount ACCU-PULSE as close to the pump discharge as possible to absorb the pulse

More information

COMMERCIAL ITEM DESCRIPTION NITROGEN, TECHNICAL

COMMERCIAL ITEM DESCRIPTION NITROGEN, TECHNICAL METRIC 3 March 2011 SUPERSEDING A-A-59503B 20 October 2008 COMMERCIAL ITEM DESCRIPTION NITROGEN, TECHNICAL The General Services Administration has authorized the use of this commercial item description

More information

East Building, PHH-30 U.S. Department New Jersey Avenue S.E. of Transportation Washington, D.C EXPIRATION DATE: June 30, 2015

East Building, PHH-30 U.S. Department New Jersey Avenue S.E. of Transportation Washington, D.C EXPIRATION DATE: June 30, 2015 November 14, 2014 East Building, PHH-30 U.S. Department 1200 New Jersey Avenue S.E. of Transportation Washington, D.C. 20590 Pipeline and Hazardous Materials Safety Administration DOT-SP 16219 EXPIRATION

More information

SEMASPEC Test Method for Determination of Cycle Life of Automatic Valves for Gas Distribution System Components

SEMASPEC Test Method for Determination of Cycle Life of Automatic Valves for Gas Distribution System Components SEMASPEC Test Method for Determination of Cycle Life of Automatic Valves for Gas Distribution System Components Technology Transfer 90120395B-STD and the logo are registered service marks of, Inc. 1996,

More information

VISI-FLO Sight Flow Indicators

VISI-FLO Sight Flow Indicators Leading The Way in Fluid Handling Solutions Worldwide VISI-FLO Sight Flow Indicators Document No. H32199PA Revised: February, 2016 OPW Engineered Systems has been manufacturing sight flow indicators for

More information

Compatible with a Wide Range of Gases or Liquids for Laboratory or Plant Applications

Compatible with a Wide Range of Gases or Liquids for Laboratory or Plant Applications Riteflow Flowmeters Compatible with a Wide Range of Gases or Liquids for Laboratory or Plant Applications Used for flow measurements in the lab, process flows in pilot plants, metering carrier gases in

More information

IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC PURPOSE

IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC PURPOSE INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC 157-20067 1 PURPOSE 1.1 The purpose of this standard is to establish an acceptable standard

More information

Sample C ylinde rs, Acce ssorie s, and O utage Tube s

Sample C ylinde rs, Acce ssorie s, and O utage Tube s www.swagelok.com Sample C ylinde rs, cce ssorie s, and O utage s Features Sizes from 10 to 3785 cm 3 (1 gal) Working pressures up to 5000 psig (344 bar) 304L and 316L stainless steel and alloy 400 2 Sample

More information

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM ASSE STANDARD #1048 - REVISED: 2009 Double Check Detector Fire Protection Backflow Prevention Assemblies Separate, complete laboratory

More information

East Building, PHH-30 U.S. Department New Jersey Avenue S.E. of Transportation Washington, D.C DOT-SP (TWENTY-THIRD REVISION)

East Building, PHH-30 U.S. Department New Jersey Avenue S.E. of Transportation Washington, D.C DOT-SP (TWENTY-THIRD REVISION) East Building, PHH-30 U.S. Department 1200 New Jersey Avenue S.E. of Transportation Washington, D.C. 20590 Pipeline and Hazardous Materials Safety Administration DOT-SP 11054 (TWENTY-THIRD REVISION) EXPIRATION

More information

Sample Cylinders and Accessories

Sample Cylinders and Accessories Sample Cylinders and Accessories SC and MC Series FITOK Group FITOK GmbH (Headquarter) Sprendlinger Landstr. 115, 6069 Offenbach am Main, Germany Tel.: +49 69 8900 4498 Fax: +49 69 8900 4495 FITOK, Inc.

More information

GAS DISTRIBUTION PRODUCTS TRANSITION FITTINGS

GAS DISTRIBUTION PRODUCTS TRANSITION FITTINGS GAS DISTRIBUTION PRODUCTS TRANSITION FITTINGS CONTINENTAL INDUSTRIES, INC. The Ultimate Connection CONTINENTAL INDUSTRIES, INC. ABOUT US THE ULTIMATE CONNECTION Our Company Continental Industries, Inc.,

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 333a 1. Description Viking supervised Surefire Preaction Systems Utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated Viking G-3000P Valve comes complete

More information

NEW Edge Series Products: OUTFITS and REGULATORS

NEW Edge Series Products: OUTFITS and REGULATORS NEW Edge Series Products: OUTFITS and REGULATORS NOW Including ESS3 Models and More Edge Series Outfits User Friendly Advanced Design Outstanding Flow Performance Unsurpassed Safety www.victoredge.com

More information

Shut-off valve Type QDV

Shut-off valve Type QDV Data sheet Shut-off valve Type QDV QDV is a shut-off valve, designed particularly for draining oil from systems containing refrigerant (ammonia) under pressure. The valve will close immediately on release

More information

CLASS D - SENSITIVE LEAK TEST GAS AND BUBBLE METHOD. 1.1 To provide definitive requirements for PNEUMATIC pressure testing of piping systems.

CLASS D - SENSITIVE LEAK TEST GAS AND BUBBLE METHOD. 1.1 To provide definitive requirements for PNEUMATIC pressure testing of piping systems. Page 1 of 7 CLASS D - SENSITIVE LEAK TEST GAS AND BUBBLE METHOD 1. SCOPE 1.1 To provide definitive requirements for PNEUMATIC pressure testing of piping systems. 1.2 The piping system as used herein is

More information

Liquid Level Controllers

Liquid Level Controllers Liquid Level Controllers ALL PUMPS LLC-2Y For both pump up and down control. Variable On/Off set points. NDP-15/20/25/32, DP-10/15 & *NDP-40/50/80 LLC-1 Pump up and down versions available. 6 to 12 differential

More information

East Building, PHH-30 U.S. Department New Jersey Avenue S.E. of Transportation Washington, D.C DOT-SP 7218 (NINETEENTH REVISION)

East Building, PHH-30 U.S. Department New Jersey Avenue S.E. of Transportation Washington, D.C DOT-SP 7218 (NINETEENTH REVISION) East Building, PHH-30 U.S. Department 1200 New Jersey Avenue S.E. of Transportation Washington, D.C. 20590 Pipeline and Hazardous Materials Safety Administration DOT-SP 7218 (NINETEENTH REVISION) EXPIRATION

More information

VCO O-Ring Face Seal Fittings

VCO O-Ring Face Seal Fittings O-Ring Face Seal Fittings www.swagelok.com O-Ring Face Seal Fittings /8 to sizes 36 or 36L stainless steel, NPT, S thread, and weld connections 2 Weld, VR,, Pipe, and Vacuum Fittings ontents Technical

More information

STANDARD FOR CONTROL VALVE SEAT LEAKAGE

STANDARD FOR CONTROL VALVE SEAT LEAKAGE 11-3 STANDARD FOR CONTROL VALVE SEAT LEAKAGE 1. PURPOSE 1.1 This standard establishes a series of seat leakage classes for control valves and defines the test procedures. 2. SCOPE & LIMITATIONS 2.1 Selection

More information

PERFORMANCE SPECIFICATION VALVE; AIRCRAFT, PNEUMATIC, HIGH-PRESSURE CHARGING

PERFORMANCE SPECIFICATION VALVE; AIRCRAFT, PNEUMATIC, HIGH-PRESSURE CHARGING INCH-POUND 10 October 1998 SUPERSEDING MIL-V-6164E 15 June 1990 1. SCOPE PERFORMANCE SPECIFICATION VALVE; AIRCRAFT, PNEUMATIC, HIGH-PRESSURE CHARGING This specification is approved for use by all Departments

More information

Pressure regulating valves Types OFV, OFV-SS

Pressure regulating valves Types OFV, OFV-SS Data sheet Pressure regulating valves Types OFV, OFV-SS OFV are angle-way pressure regulating valves, which have ajustable opening pressure and cover the differential pressure range ( P): 2-8 bar (29 116

More information

Gas Boosters & Systems

Gas Boosters & Systems DRIVEN Gas Boosters & Systems SINGLE ACTING - SINGLE STAGE PRESSURES UP TO 10,875 psi DOUBLE ACTING- SINGLE STAGE PRESSURES UP TO 21,750 psi TWO STAGE PRESSURES UP TO 21,750 psi DOUBLE HEAD - SINGLE AND

More information

600 Series. Brass Ball Valves

600 Series. Brass Ball Valves Series Brass Ball Valves full range of economical brass ball valves intended for your common fluid control applications. vailable in standard and full port threaded, full port solder end, and full port

More information

Standard Pneumatic Test Procedure Requirements for Piping Systems

Standard Pneumatic Test Procedure Requirements for Piping Systems the pressure equipment safety authority Standard Pneumatic Test Procedure Requirements for Piping Systems AB-522 Edition 2, Rev. 1 Issued 2016-10-24 Table of Contents FOREWORD... 1 1.0 INTRODUCTION...

More information

PIP PNE00012 Piping Examination and Leak Test Guide

PIP PNE00012 Piping Examination and Leak Test Guide October 2017 Piping PIP PNE00012 Piping Examination and Leak Test Guide PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort to minimize the cost of process industry facilities, this Practice has

More information

Quick closing oil drain valve, type QDV 15 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Quick closing oil drain valve, type QDV 15 REFRIGERATION AND AIR CONDITIONING. Technical leaflet Quick closing oil drain valve, type QDV 15 REFRIGERATION AND AIR CONDITIONING Technical leaflet Introduction QDV is a quick closing oil drain valve, designed particularly for draining oil from systems

More information

NEW EDGE SERIES REGULATORS & OUTFITS

NEW EDGE SERIES REGULATORS & OUTFITS WE LISTENED. WE DELIVERED. NEW EDGE SERIES REGULATORS & OUTFITS Victor Introduces the Newest Addition to the EDGE Series: The EHP3 High Pressure Regulator. EDGE Regulators Now Include These Models EHP3

More information

Limited quantities of compressed gases.

Limited quantities of compressed gases. 173.306 Limited quantities of compressed gases. (a) Limited quantities of compressed gases for which exceptions are permitted as noted by reference to this section in 172.101 of this subchapter are excepted

More information

Solenoid valves, two-step on/off Type PMLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Solenoid valves, two-step on/off Type PMLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet Solenoid valves, two-step on/off PMLX REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction........................................................................................3

More information

Continental Industries TRANSITION FITTINGS or FAX Visit

Continental Industries TRANSITION FITTINGS or FAX Visit Continental Industries TRANSITION FITTINGS 1-800-558-1373 or FAX 1-800-788-1668 Visit www.conind.com ABOUT US Our Company Continental Industries, headquartered in Tulsa, Oklahoma, was formed in 1958 and

More information

Pressure Equalising Valves Model , for Differential Pressure Gauges

Pressure Equalising Valves Model , for Differential Pressure Gauges Accessories Pressure Equalising Valves Model 910.25, for Differential Pressure Gauges WIKA Data Sheet AC 09.11 Applications T Isolating, pressure equalising as well as purging and air bleeding valves to

More information

Mass Flow Controllers

Mass Flow Controllers Mass Flow Meters & Controllers HFM-D-3A & 305A Mass Flow Meters HFC-D-3A & 307A Mass Flow Controllers FEATURES Range 0-25 slm to 0-2500 slm (N 2 Equivalent) Excellent Accuracy ±(0.5% of Reading + 0.2%

More information

Mark 630 Series. High Pressure Regulators Mark 630 High Pressure Regulators. High Pressure Regulators. Features

Mark 630 Series. High Pressure Regulators Mark 630 High Pressure Regulators. High Pressure Regulators. Features Mark 630 Series High Pressure Regulators The Jordan Mark 630 self-operated pressure reducing regulator is designed to provide tight shutoff and accurate regulation on high pressure gas systems. It can

More information

490 Micro GC Site Preparation Checklist

490 Micro GC Site Preparation Checklist Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation

More information

CPVC Transition Fittings - Female Adapter. CPVC X LEAD FREE BRASS Lead Free Max working pressure F ASTM D 2846

CPVC Transition Fittings - Female Adapter. CPVC X LEAD FREE BRASS Lead Free Max working pressure F ASTM D 2846 CPVC Transition Fittings - Female Adapter STD4703BTLF12 1/2 CPVC X 1/2 FIP 25 250 CPVC Transition Fittings - Female Adapter STD4703BTLF34 3/4 CPVC X 3/4 FIP 25 250 CPVC Transition Fittings - Female Adapter

More information

DataSheet. Series AA Electronic Metering Pumps. Configuration Data. Dimensions. Specifications. Model AA HI. ISO 9001 Certified

DataSheet. Series AA Electronic Metering Pumps. Configuration Data. Dimensions. Specifications. Model AA HI. ISO 9001 Certified DataSheet Series AA Electronic Metering Pumps Configuration Data Model AA 9 4 1-358HI Control Code 1 --- Manual Control: Speed (stroking frequency) and stroke length manually adjustable. 7 --- Instrument

More information

Team Insert Valve Sample Specification The Insert Valve shall conform to the following:

Team Insert Valve Sample Specification The Insert Valve shall conform to the following: Team Insert Valve Sample Specification The Insert Valve shall conform to the following: The Ductile Iron 250 p.s.i.g. Insert Valve shall be a Resilient Wedge Gate Valve designed for use in potable water,

More information

Type 4708 Supply Pressure Regulator

Type 4708 Supply Pressure Regulator Type 708 Pressure Regulator Application pressure regulator used to provide pneumatic measuring and control equipment with a constant air supply Set point range 0.5 to bar (8 to 90 psi) The pressure regulator

More information

TBV Series 5100 Diverter/Three-Way Ball Valve

TBV Series 5100 Diverter/Three-Way Ball Valve TBV Series 5100 Diverter/Three-Way Ball Valve TBV Series 5100 Ball Valve Manifolding Diverting Blending Replaces the use of two or more two-way valves Cameron s TBV brand offers the Series 5100 diverter/three-way

More information

Storage Systems and Accessories

Storage Systems and Accessories Storage Systems and Accessories High Pressure Air and Inert Gases 4500-6000 PSIG DOT and ASME Cylinders High Pressure Storage Systems If an application requires storage, either in the form of a single

More information

UNDERWATER VEHICLES, SYSTEMS AND HYPERBARIC FACILITIES 2002

UNDERWATER VEHICLES, SYSTEMS AND HYPERBARIC FACILITIES 2002 RULES FOR BUILDING AND CLASSING UNDERWATER VEHICLES, SYSTEMS AND HYPERBARIC FACILITIES 2002 NOTICE NO. 5 January 2008 The following Rule Changes were approved by the ABS Rules Committee on 7 June 2007

More information

PERFORMANCE SPECIFICATION PROPELLANT PRESSURIZING AGENT, NITROGEN

PERFORMANCE SPECIFICATION PROPELLANT PRESSURIZING AGENT, NITROGEN METRIC 07 August 2013 SUPERSEDING MIL-PRF-27401F 10 January 2008 PERFORMANCE SPECIFICATION PROPELLANT PRESSURIZING AGENT, NITROGEN Comments, suggestions, or questions on this document should be addressed

More information

Air Operated Hydraulic Pumping Systems to 50,000 psi

Air Operated Hydraulic Pumping Systems to 50,000 psi High Pressure Equipment Air Operated Hydraulic Pumping Systems to 50,000 psi PS-10: 10,000 psi PS-20: 20,000 psi PS-30: 30,000 psi PS-40: 40,000 psi PS-50: 50,000 psi PS-90: 90,000 psi High Pressure air

More information

CHECK VALVES APPLICATIONS

CHECK VALVES APPLICATIONS 45 APPLICATIONS The check valves, shown in this chapter, are classified Pressure accessories in the sense of the Pressure Equipment Directive 97//EC, Article 1, Section 2.1.4 and are subject of Article

More information

CLASS DH - PNEUMATIC TESTING - GREATER THAN 1 BAR (15 PSIG)

CLASS DH - PNEUMATIC TESTING - GREATER THAN 1 BAR (15 PSIG) Page 1 of 10 CLASS DH - PNEUMATIC TESTING - GREATER THAN 1 BAR (15 PSIG) 1. SCOPE 1.1 To provide definitive requirements for HIGH PRESSURE PNEUMATIC testing of piping systems according to ASME B31.3. This

More information

High Pressure Equipment Taper Seal Valves, Fittings and Tubing

High Pressure Equipment Taper Seal Valves, Fittings and Tubing igh quipment Taper Seal Valves, ittings and Tubing 0,000 and,000 psi service igh quipment Company has developed the Taper Seal line of products to assure safe and easy plumbing through,000 psi. These needle

More information

Section GATE VALVES

Section GATE VALVES Section 02521 PART 1 GENERAL 1.01 SUMMARY This Section includes the furnishing and installation of gate valves for isolation and dead-end service as shown on Plans and as specified herein. 1.02 MEASUREMENT

More information

TYPE ECS SEAL METAL BELLOWS DRY-RUNNING SECONDARY CONTAINMENT Technical Specification

TYPE ECS SEAL METAL BELLOWS DRY-RUNNING SECONDARY CONTAINMENT Technical Specification Low Temperature Design A Spacer Ring B Compression Ring C Retaining Ring D Wave Spring E O-ring F ent/drain Connection G Seat/Mating Ring H Insert I Bellows Assembly J Housing A K Spacer B F G H I C D

More information

Model PDT Dewpoint Transmitter

Model PDT Dewpoint Transmitter Model PDT Dewpoint Transmitter Instruction Manual Alpha Moisture Systems Alpha House 96 City Road Bradford BD8 8ES England Tel: +44 1274 733100 Fax: +44 1274 733200 email: mail@amsytems.co.uk web: www.amsystems.co.uk

More information

Flange Adapters. Threadless, weldless transition from flanged piping systems to tubing systems

Flange Adapters.   Threadless, weldless transition from flanged piping systems to tubing systems www.swagelok.com Flange dapters Threadless, weldless transition from flanged piping systems to tubing systems Flange types meet SM, IN, N, and IS standards One-piece integrally machined forged body vailable

More information

COMPRESSION TUBE FITTINGS 1/16 THROUGH 2 -INCH, 2 MM THROUGH 50 MM-METRIC

COMPRESSION TUBE FITTINGS 1/16 THROUGH 2 -INCH, 2 MM THROUGH 50 MM-METRIC 1/16 THROUGH 2 -INCH, 2 MM THROUGH 50 MM-METRIC LET-LOK TUBE FITTINGS DESCRIPTION HAM-LET LET-LOK HOW DOES IT WORK? HAM-LET LET-LOK LET-LOK LET-LOK HAM-LET LET-LOK 1 4 3 2 4 Tube 1 2 3 1 2 3 4 6 LET-LOK

More information

PERFORMANCE SPECIFICATION VALVE; AIRCRAFT, PNEUMATIC, HIGH-PRESSURE CHARGING

PERFORMANCE SPECIFICATION VALVE; AIRCRAFT, PNEUMATIC, HIGH-PRESSURE CHARGING INCH-POUND 16 October 2012 SUPERSEDING MIL-PRF-6164F 10 October 1998 PERFORMANCE SPECIFICATION VALVE; AIRCRAFT, PNEUMATIC, HIGH-PRESSURE CHARGING This specification is approved for use by all Departments

More information

PANACEA P200 STAINLESS STEEL USER MANUAL

PANACEA P200 STAINLESS STEEL USER MANUAL Basic Features Stainless Steel body with 1.75 outside diameter. Will fit into wells down to 2 (schedule 80). Has an internal chamber volume of 200mL. Maximum depth below ground surface of 3000ft. Other

More information

WaterSource Heat Pump Hose Kit Performance Specification-Summary

WaterSource Heat Pump Hose Kit Performance Specification-Summary WaterSource Heat Pump Hose Kit Performance Specification-Summary AUTOMATIC & MANUAL BALANCING HOSE KITS Contractor shall provide and install Hays Hose Kits. Each kit, shall include a Hays 2500 Series Mesurflo

More information

Part 4 Machinery and systems Chapter 6 Piping systems, pumps and compressors

Part 4 Machinery and systems Chapter 6 Piping systems, pumps and compressors RULES FOR CLASSIFICATION Underwater technology Edition December 2015 Part 4 Machinery and systems Chapter 6 Piping systems, pumps and compressors The content of this service document is the subject of

More information

R Z JUN 04 PSN M29 FM COMNAVSEASYSCOM WASHINGTON DC TO RUCOSSA/COMNAVAIRLANT NORFOLK VA RUCBTFA/COMNAVSURFLANT NORFOLK VA

R Z JUN 04 PSN M29 FM COMNAVSEASYSCOM WASHINGTON DC TO RUCOSSA/COMNAVAIRLANT NORFOLK VA RUCBTFA/COMNAVSURFLANT NORFOLK VA R 030510Z JUN 04 PSN 841826M29 FM COMNAVSEASYSCOM WASHINGTON DC TO RUCOSSA/COMNAVAIRLANT NORFOLK VA RUCBTFA/COMNAVSURFLANT NORFOLK VA RUCBCLF/COMFLTFORCOM NORFOLK VA ZEN/COMNAVAIRPAC SAN DIEGO CA ZEN/COMNAVSURFPAC

More information

Type 4708 Supply Pressure Regulator

Type 4708 Supply Pressure Regulator Type 478 Pressure Regulator Application pressure regulator used to provide pneumatic measuring and control equipment with a constant air supply Set point ranges. to.6 bar ( to 4 psi) or. to 6 bar (8 to

More information

Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES. ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified

Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES. ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified TYPE G-4 DESCRIPTION FIG 2042 - Bronze FIG 2043 - Bronze

More information

v. Size shall be specified on drawings.

v. Size shall be specified on drawings. SPECIFICATION FOR VACUUM INSULATED PIPING Part 1 General 1. Submittals a. After award of contract and before executing any manufacturing, shop drawings and specifications shall be submitted to the customer

More information

North American Simplex Basket Strainers for Gas and Oil

North American Simplex Basket Strainers for Gas and Oil Combustion North American Simplex Basket Strainers for Gas and Oil A mesh lining (304 stainless standard or 316 stainless or monel special), either 20, 40 or 100 mesh, can be provided, depending on the

More information

M A B MAB INFLATABLE GASKET SLIDE VALVES SERIES TSV FOR POWDERED AND GRANULAR SOLID MATERIALS

M A B MAB INFLATABLE GASKET SLIDE VALVES SERIES TSV FOR POWDERED AND GRANULAR SOLID MATERIALS Automatic slide valves type TSV-150 with inflatable sealing system. The range of TSV slide valves supplied by MAB can always close against a head of flowing solids. The TSV series of inflatable gasket

More information

Bladder-Type Accumulators

Bladder-Type Accumulators 18 ladder-type ccumulators n Overview The typical bladder accumulator makes use of the considerable differences in the relative compressibility between a gas and a fluid. typical design consists of a gas

More information

hydro-pac, inc. Low-Pressure Gas Compressors 1500 to 6000 PSI

hydro-pac, inc. Low-Pressure Gas Compressors 1500 to 6000 PSI hydro-pac, inc. LX-SERIES Low-Pressure Gas Compressors 1500 to 6000 PSI hydro-pac, inc. LX-SERIES Features Hydro-Pac LX-SERIES Gas Compressors feature: Oil-free non lubricated gas pistons and cylinders

More information

VCO O-ring Face Se al Fit tings

VCO O-ring Face Se al Fit tings www.swagelok.com O-ring Face Se al Fit tings /8 to sizes 36 or 36L stainless steel, NPT, S thread, and weld connections 2 O-ring Face Seal Fittings ontents Features........................................

More information

precision pipe fittings

precision pipe fittings Precision Pipe Fittings 1 8 to 1 sizes 316 stainless steel, brass, and exotic materials NPT threads HOKE PO Box 4866 Spartanburg, SC 29305-4866 Phone (864) 574-7966 Fax (864) 587-5608 www.hoke.com Sales-hoke@circor.com

More information

Multiple Tube Flowmeters

Multiple Tube Flowmeters Multiple Tube Flowmeters xp The model xp multiple tube flowmeter line offers, the convenience and simplicity of 2, 3, 4, 5 and 6 tube meters, retaining most of the unique design features associated with

More information