2-Phase Filters(Direct IEC Connector) RoHS. 250V AC 50/60Hz 1,2,3,6,10A KC, UL, CSA, VDE+ENEC, TÜV, CQC, 25 / 85 / 21
|
|
- Meagan Maxwell
- 5 years ago
- Views:
Transcription
1 2-Phase Filters(Direct IEC Connector) IG IM IL IX ID Rated Voltage/ Frequency 1,2,3,6,10A KC, UL, CSA, VDE+ENEC, TÜV, CQC, Climatic Category IG, IX, ID : IM, IL : Plastic Case IG, IX, ID : Screw and PCB Mounting IM : PCB Mounting IM, IL : PCB Pin IG, IX, ID : Faston Tab #250, PCB Pin, Soldering Lug Input Terminal IEC Connector (Compatible with IEC ) Effective Frequency Range IG, IM, IL, ID : IX : 100kHz~50MHz IG, IM, IL, ID IX Circuit Diagram 50g 30g 30g 50g 45g LED/PDP/LCD/Projection TVs. Monitors, Measuring equipments, Computers and Peripherals, Telecommunication equipments.
2 DIT Product Families 2-Phase Filters(Direct IEC Connector) IH IJ1 IF IK IF2 IE1/IE3 1,2,3,6,10A 3,5,6,8,10A 1,2,3,6,10A 3,6,8,10A 3,6,10A IH, IF, IK : KC, UL, CSA, VDE+ENEC, TÜV, CQC, IJ1, IF2 : KC, UL, CSA, VDE+ENEC, CQC, IE1 : KC(IE3), UL, CSA, VDE+ENEC (IJ1, IF2 : 25 / 100 / 21) IJ1, IF, IE1, IE3 : IH, IK : Snap-in with Lock Spring IJ1, IH : Faston Tab #250, Soldering Lug IF, IK : PVC Insulated Wire UL 1617 AWG #22 IE1, IE3 : Faston Tab #250 IEC Connector (Compatible with IEC ) IH, IF, IK IJ1 IF2 IE1 IE3 45g 75g 50g 50g 75g 210g LED/PDP/LCD/Projection TVs. Monitors, Measuring equipments, Computers and Peripherals, Telecommunication equipments.
3 Power Entry Module with EMI Filters IP IQ IS Rated Voltage/ Frequency 2,4,6A IP, IQ : KC, UL, CSA, TÜV IS : KC, UL, CSA, SEMKO+ENEC Climatic Category IP, IS : IQ : Snap-in with Lock Spring Faston Tab #250 Input Terminal Effective Frequency Range IEC Connerctor (Compatible with IEC ) Circuit Diagram 130g 130g 130g LED/PDP/LCD/Projection TVs. Monitors, Measuring equipments, Computers and Peripherals, Telecommunication equipments.
4 DIT Product Families Power Entry Module with EMI Filters IR IR2 IR3 2,4,6A 3,6,10A IR : KC, UL, CSA, TÜV IR2, IR3 : KC, UL, CSA, VDE+ENEC Faston Tab #250 IEC Connerctor (Compatible with IEC ) 78g 78g 78g LED/PDP/LCD/Projection TVs. Monitors, Measuring equipments, Computers and Peripherals, Telecommunication equipments.
5 2-Phase Filters(Potted with Epoxy Resin) HP1 CL1/CL2 CN1,2,3 CA5 DS1 Rated Voltage/ Frequency 1A~3.6A 1A~6A 1,2,3,6A 3,5,8,10A KC, UL, CSA, VDE+ENEC TÜV KC, UL, CSA, TÜV Climatic Category Plastic Case PCB Mounting CA5, DS1, ES1, ES3, CL1, CL2 : CN1, CN2, CN3 : Plastic Case Input Terminals PCB Mounting CL1, CL2, CN1, CN2, CN3 : Faston Tab #110 DS1, ES1, ES3, : Faston Tab #250, M4 stud, M5 stud Effective Frequency Range CN1 CL1 CA5-V CN2 Circuit Diagram CL2 CN3 CA5-W 17.5g 27g 60g 90g 150g Measuring equipments, Computers and Peripherals, Industrial equipments such as UPS, Inverter, Converter Telecommunication equipments, FA equipments, Computerized washing machines.
6 DIT Product Families 2-Phase Filters(Potted with Epoxy Resin) ES1/ES3 TB1 TBA TBB PC2,3,4/SW3 3~30A 6A/10A/16A 20A/30A 6A/10A/16A 20A/30A 6A/10A/16A/20A 12A~20A KC, UL, CSA, TÜV SEMKO, KC, culus, CQC CE, SEMKO, KC, culus, CQC(Pending) PC2,3,4 : KC, UL, CSA, TÜV SW3 : KC Plastic Case Aluminum Cylinder &Din Rail Mounting Panel Mounting with M8-Hex Nut ES1, ES3 : Faston Tab #250, M4 Stud, M5 Stud TB1 : M5 Terminal Block TBA : M4 Terminal Block TBB : M3.5 Terminal Block PC1,2,3, SW3 : Faston Tab #250 ES1 PC2 SW3 PC3 ES3 PC4 1A~20A:250g 30A:720g 340g 300g 180g 180g Measuring equipments, Computers and Peripherals, Industrial equipments such as UPS, Inverter, Converter Telecommunication equipments, FA equipments, Computerize washing machines.medical equipments, X-Ray Machines
7 3-Phase Filters(Potted with Epoxy Resin) SQ3 TY1/SQ5 TB6 ~440V AC 50/60Hz 3Line 4Line 15A~30A 3A~16A SQ5 : UL ~440V AC, 50/60Hz 3Line 10A/20A/30A/ 40A/60A/80A SEMKO, ENEC,CE 100A/150A/200A/ 250A/400A 480V AC 600A/800A/1000A/1600A SEMKO, ENEC, CE (600A~1600A Pending) 25 / 100 / 21 - Faston Tab #250 - M4 Stud 10A/20A/30A : M4 Terminal Block 40A : M5 Terminal Block 60A/80A : M6 Terminal Block 100A/150A : M8 Terminal Block 200A/250A : M10 Terminal Block 400A : Bus Bar Bus Bar TY1 10A/20A/30A 60A/80A/100A/ 150A 600A/800A /1000A 1600A SQ5 40A 200A/250A /400A 1,400g TY1 : 250g SQ5 : 1,450g 10A/20A/30A : 1,300g 40A : 1,600g 60A/80A : 3,600g 100A : 3,600g 150g : 5,300g 200A/250A : 7,500g 400A : 11,000g 600A : 16,000g 800A/1000A : 20,000g 1600A : 24,000 Industrial equipments such as CNC Machine, Inverter, Converter, Telecommunication equipments, FA equipments Elevator,Servo Motor Driver.
8 DIT Product Families HA1/HA2 PLC Decoupling Filters HA4 HA1 Standard Rating Operating Frequency In/ 3 ~100A ~100A ~16A HA1 : KC, UL, CQC HA2 : KC, UL 95kHz~130kHz, 110kHz~140kHz KC, UL Plastic Case KC, UL Plug-in M6(50A Max), M8(100A Max) Terminal Block PLC Home Network(Apartment, Office Building, Hotel, etc...) Common Mode Choke Coils LS4 LC4 LSA LHA Inductance Operating Temp. 1A~5A ~20mH -25 ~105 1A~20A ~30mH -25 ~105 LS6 LH6 LS3 LH3 Inductance Operating Temp. 1A~15A ~35mH -25 ~120 PCB Mounting Plastic stand 1A~20A ~16mH -25 ~120 Circuit Diagram
9 DAC-11 Appliance Inlet Appliance Outlet DAC-12 DAC-12PH DAC-14 DAC-15 DAC-17 Standard Rating Input Terminal DAC-11,12, 12PH : KC, UL, CSA, VDE, SEMKO, CCC DAC-14 : KC, UL, CSA, TÜV, CCC Screw Snap-in PCB Mounting Mounting Faston Tab #187, #250 Soldering Lug 10A 16A KC, TÜV, SEMKO IEC Connector (Compatible with IEC ) 20A UL, CSA Screw Mounting 10A KC, UL, CSA Snap-in PCB Pin Faston Tab #250 10g 7.5g 7g 17g 14.8g 14.5g Appliance Inlet Power Entry Modules DAC-18 DAC-18A DAC-18C DAC-13 DAC-29 DAC-30 Standard Rating Input Terminal 2.5A/5A 2.5A : KC, TÜV, SEMKO, CCC 5A : UL, CSA PCB Pin 2.5A : KC 5A : UL, CSA KC, UL, CSA SEMKO KC, UL+cUL, VDE, CCC PCB Mounting IEC Connector (Compatible with IEC ) 3.2g 10A Faston Tab #187 or #250 Soldering Lug 3.6g 19g 21g 24g Applicable to all types of electric equipments such as measuring instruments, SMPS, ITE and OA equipments. Fuseholder (IEC ) 5*20 1-pole 5*20 2-pole Line Switch (IEC ) 2-pole
Miniature controls. Contactors. Overload relays. Starters. Control relays
Contactors Overload relays Starters Control relays Description General features Wiring terminations available include plugon connectors, wire pins for PC board mounting and solder connections Low power
More informationTolerance code. Lead space
FEATURES Non-inductive construction. Self-healing. Flame-retardant plastic case and epoxy resin (compliance with UL 94V-0). High moisture-resistance. Good solderability (plated with 100% Matte Sn). APPLICATIONS
More informationMeta-MEC Manual Motor Starters
www.lsis.biz Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 45 mm 70 mm 63AF 100AF 3 LS Meta-MEC Manual Motor Starters deliver more
More informationRELAY PRODUCT GUIDE CONTENTS
RELAY PRODUCT GUIDE CONTENTS 1.0 ABOUT FUJITSU COMPONENTS 1.1 Who we are Page 2 2.0 PRODUCT LINE-UP 2.1 Automotive relays Page 3 2.2 Power relays Page 8 2.3 Signal relays Page 16 2.4 High frequency relays
More informationZelio Relays RSL Slim Interface Plug-In Relays
Zelio Relays RSL Slim Interface Plug-In Relays Catalog 8501CT0901 2009 Class 8501 CONTENTS Description............................................. Page Introduction.................................................3
More informationTeSys protection components
Presentation, description -pole thermal overload relays TeSys D Presentation TeSys D thermal overload relays are designed to protect a.c. circuits and motors against: b overloads, b phase failure, b excessively
More informationPRODUCT SPECIFICATION
MINI-FIT SR. SERIES 1.0 SCOPE This specification covers the 10.00 mm / (.394 in.) centerline tin and gold plated connector series, single and dual row versions in wire to wire and wire to printed circuit
More informationX2 Metallized Polypropylene Film Capacitor JFV
FEATURES: Non-inductive, (UL940V-0) plastic case sealed with epoxy resin. Provides interference suppression with VDE, ENEC and UL approvals. SPECIFICATIONS: Operating Temperature -40 ~ +110 Maximum Continuous
More informationRoHS. WS Series Snap Action Switch. Specifications. Part Number Configurator
Applications / Markets HVAC Electrical Housewares Floor Care Appliances Specifications White Goods Vending Machines Features & Benefits Medical Equipment RoHS Contact Rating: 0.5A @ 42VDC 1A @ 24VDC 2A
More informationPrewired position switches FA series
2 Prewired position switches FA series Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 51 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable lever 41 45
More informationPosition switches FP series
A Position switches FP series Selection diagram 0 08 8 9 0 0 0 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fiber glass rod gasket sphere sphere adjustable lever safety adjustable lever
More informationVLT 2000 Series. How to size your VLT
Selection of frequency converter Usually the size of frequency converter is chosen on the basis of the shaft output, as this may be the only value known. However, if the data are known for both the application,
More informationThe Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure
General-purpose Limit Switch CSM_DA-_N_DS_E The Limit Switch with Better Seal, Shock Resistance, and Strength A double seal on the head, a complete gasket cover, and other features ensure a better seal
More informationFMAC Sine FMAC Sine DCL
emc Sine Output Filter www.schurter.com/pg8 FMAC Sine FMAC Sine DCL -Phase Filters Sine wave output filter Description - Design corresponding to UL 128, CSA 22.2 No. 8, IEC/EN699 - Standard versions include
More informationInnovative Solutions for Building Safety & Security
Innovative Solutions for Building Safety & Security TE Connectivity (TE) is your building safety and security solution provider for electromechanical and electronic components. Whether you are designing
More informationX2 Metallized Polypropylene Film Capacitor JFV
FEATURES: Non-inductive, (UL940V-0) plastic case sealed with epoxy resin. Provides interference suppression with VDE, ENEC and UL approvals. SPECIFICATIONS: Operating Temperature -40 ~ +110 Voltage Rating
More informationPrewired position switches FA series
Prewired position switches Technical data Housing Made of metal, coated with baked epoxy powder 2 m wired cable with 5x0,5 mm 2 wires marked SEV and IMQ Protection degree: IP6 General data Ambient temperature:
More informationScrew Terminal Block Cables
9 Screw Terminal Block s Pre-terminated s Simplify of Terminal Blocks to PLC Modules 1 Reduce setup time with cables pre-terminated for the exact PLC module in use 1 No need to make custom connectors 1
More informationSPECIFICATION FOR APPROVAL
RoHS Compliant SPECIFICATION FOR APPROVAL File No.: Q/FRK 0.GS.E.-F03 Product Name Product Type Safety class S3(P2) Metallized polypropylene film AC motor capacitor(box-type) [CBB61-S3(P2)] Product Code
More informationConductor Bushings Series 8174
> Current lead-in for Ex d enclosures > 1 to 72 conductors combined in one current lead-in > Series screw-in plug-in > For voltages up to max. 1 V > For size conductor up to 7 mm 2 www.stahl.de 3163E The
More informationOperating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073
Operating instructions Safety Rope Emergency Stop Switches UK ZB0052 / ZB0053 ZB0072 / ZB0073 7390878 / 02 03 / 2011 Contents 1 Safety instructions...3 2 Installation / set-up...4 2.1 Applications...4
More informationTANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR
SIT Group 836-837 TANDEM MULTIFUNCTIONAL GAS CONTROL MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR ALL ADJUSTMENTS ACCESSIBLE FROM ABOVE
More informationTechnical Data. Dimensions
00 Model Number Features Comfort series 30 mm non-flush Accessories MHW 0 Modular mounting bracket V-G Female connector, M, 4-pin, field attachable V-W-N-M-PUR Female cordset, M, -pin, NAMUR, PUR cable
More informationAutomatic Valve Proving Control
ISO 9001 Automatic Valve Proving Control 7 696 LDU11 UL recognized FM approved Features Performs leak test of the gas shut-off valves before start-up and/or immediately after burner shut-down No inlet
More informationReferences 6 k thermal overload relays, adjustable from 0.11 to 16 A
s 6 k thermal overload relays, adjustable from 0.11 to 16 A 3-pole relays with screw clamp terminals These overload relays are designed for the protection of motors. They are compensated and phase failure
More informationMeta-MEC Manual Motor Starters
Leader in Electrics & Automation Meta-MEC Manual Motor Starters Electric Equipment LG Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 45 mm 70 mm 63AF 100AF 3 LG Meta-MEC
More informationDSB, DSF: Pressure monitors and pressure switches
roduct data sheet 23.760 DSB, DSF: ressure monitors and pressure switches How energy efficiency is improved Control and monitoring according to needs and with no auxiliary energy Features For regulating
More informationMV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:
MV-01 2/2-way Solenoid Valve for Fluids Description: Features / Nominal diameters 1/4-2 / Pressure up to 10 bar / 24 V DC and all common AC variants / Forced-lifting The pilot-controlled full-way valve
More informationTechnical Data. Dimensions
0102 Model Number Features 2 mm flush Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 2 mm Installation flush Output
More informationPROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road
PROPORTIONING VALVE Model 150 INSTRUCTION MANUAL March 2017 IMS Company 10373 Stafford Road Telephone: (440) 543-1615 Fax: (440) 543-1069 Email: sales@imscompany.com 1 Introduction IMS Company reserves
More informationSolenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners
7 634 VGS1... with AGA67 connector VGS2... with AGA67 connector Solenoid gas valve VGS The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners The VGS and
More informationElectric regulating valves Type CCMT 2 - CCMT 8 / CCMT 16 - CCMT 42
Data sheet Electric regulating valves Type CCMT 2 - CCMT 8 / CCMT 16 - CCMT 42 The CCMT is an electrically operated valve designed specifically for operation in CO 2 systems. The CCMT valve concept is
More informationInfrared Linescanners
Thermal Imaging and Temperature Profiles for Continuous Process Monitoring and Quality Control HD Infrared Linescanners PROCESS & ANALYTICAL INSTRUMENTS Mountings and Accessories LSPHD Mountings and Accessories
More informationMULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE
SIT Group SIT -3- SIGMA MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE 9.955. Subject to change without notice Application Domestic gas appliances: central heating boilers, combi boilers, instantaneous
More informationDimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm
Dimensions 65 GW2 40 35 9 5 GW1 14 11 9 5.4 M20 x 1.5 0102 Model Number S M12 x 1.5 Features 77.5 LED V Direct mounting on standard actuators Compact and stable housing with terminal compartment connection
More informationTechnical Data. Dimensions
00 Model Number Features mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,
More informatione2c 20 - easy to connect
closer contacts Fieldbus Communications e2c 20 - easy to connect e2c 20 / IP 20 Distributed I/O System for Switch Cabinets Switch cabinets and distribution boxes continue to rely on wiring systems that
More information1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition
Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.
More informationEPIC Rectangular Connector Inserts. HBE Series. Technical Data Number of Contacts:
HBE Series HBE series inserts provide reliable termination and performance in the vast majority of medium power and control applications. Methods of termination include screw, crimp, and spring cage clamp.
More informationElectric expansion valves Types AKV 10, AKV 15 and AKV 20
Data sheet Electric expansion valves Types AKV 10, AKV 15 and AKV 20 AKV are electrically operated expansion valves designed for refrigerating plants. The AKV valves are normally controlled by a controller
More informationTechnical Data. Dimensions
0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable
More informationTECHNICAL INFORMATION
TECHNICAL INFORMATION Model No. Description RP2300FC, RP2301FC Router CONCEPT AND MAIN APPLICATIONS Models RP2300FC and RP2301FC are upgraded sister tools of our current plunge-type electronic router Model
More informationHEATING, VENTILATION & AIR CONDITIONING SYSTEMS INNOVATIVE SOLUTIONS. Stay ahead of the trends for increased building comfort and control
HEATING, VENTILATION & AIR CONDITIONING SYSTEMS INNOVATIVE SOLUTIONS Stay ahead of the trends for increased building comfort and control SUBSYSTEMS DESIGN NAVIGATOR CONTROL SYSTEMS AUXILIARY PCB S ENVIRONMENTAL
More informationData sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119
Pressure switch type CS December 2001 DKACT.PD.P10.A2.02 520B1119 Introduction Pressure switch type CS is part of the Danfoss pressure control range. All CS pressure switches have a built-in pressure-operated,
More informationCircuit breakers PR 60
Circuit breakers PR series are mechanical switching devices able to switch, conduct and switch-off the current under normal conditions and able to switch, conduct and automatically switch-off the current
More informationQPL... Pressure Switches. Siemens Building Technologies HVAC Products
7 221 Pressure Switches QPL... The pressure switches are used for monitoring gas or air pressures. When the pressure falls below the switching point, the associated electrical circuit will open or switch
More informationPneumatic spool valve islands
Pneumatic spool valve islands P7.GB.R MEGA SPOOL VALVE ISLANDS MEGA pneumatic spool valve islands offer maximum performance along with flexibility, easy installation and simple operation. Due to their
More informationElectromechanical pressure switches
References : pages / and / page /5 Presentation Functions Pressure switches type XMX and XMA are switches for control circuits, with an adjustable differential. They are used to control the pressure of
More informationD. ACCESSORIES ADAPTER KITS IMPELLER & SEAL INSTALLATION TOOLS CARRYING HANDLES & LIFT CORDS GALVANIC PROTECTION KITS MUSHROOM STRAINER
. ACCESSORIES AAPTER KITS IMPELLER & SEAL INSTALLATION TOOLS CARRYING HANLES & LIFT CORS GALVANIC PROTECTION KITS MUSHROOM STRAINER SLUGE STRAINERS NEMA 4 WATERTIGHT CONTROL & UAL LEVEL CONTROL (Replaces
More informationTypes and approvals. Page 1/6. Data Sheet
Page 1/6 Panel-mounting Thermostats EM Series as: Protection temperature monitor STW (STB) Protection temperature limiter STB tested to DIN 3440 and Pressure Equipment Directive 97/23/EC Brief description
More informationASM. Asynchronous Spindle Motors. SEM Limited Faraday Way Orpington, Kent BR5 3QT United Kingdom
NE ASM Asynchronous Spindle Motors SEM Limited Faraday Way Orpington, Kent BR 3QT United Kingdom Tel: +44 ()189 8847 Fax: +44 ()189 884884 Email: sales@sem.co.uk Web: www.sem.co.uk Version 4 August 2 Asynchronous
More informationPressure switch Type BCP
Data sheet Pressure switch Type BCP The BCP type is a series of dedicated switches for safety and monitoring of steam and hot water boilers. The BCP incorporates a single-pole changeover microswitch where
More informationINSTRUCTION MANUAL FOR. Chlorinator M 3600 C Controlmatik ABW
INSTRUCTION MANUAL FOR Chlorinator M 3600 C 2014 Controlmatik ABW 1 CONTENTS 1. General... 3 2. Operation... 4 2.1 Automatic control... 6 2.2 Manual control - 1... 6 2.3 Manual control - 2... 6 3. Motor
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 5 mm
00 Model Number Features 5 mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,
More informationSPECIFICATIONS ATTENTION
VPS 504 S06 Installation Manual - P/N 80122 - Ed. 01/09 VPS 504 S06 and S05 Valve Proving System Installation Instructions VPS 1 6 Gases Natural gas, air and other inert gases. NOT suitable for butane
More informationLevel transmitter LT 100
KROHNE 09/2001 7.02363.21.00 GR/PRINTO Level transmitter LT 100 Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters
More informationEmergency Stop Devices/Rope Pull Switches
Rope pull switch with pulltoreset button for emergency stop device Metal housing Emergency stop device with detent mechanism according to EN ISO 13850 and EN 602041 Clamping head for pull rope Indication
More informationLimit switches OsiSense XC Special For material handling applications, type XC1 AC
Presentation For material handling applications, type XC C b XC C with slow break contacts v With head for linear movement () 00_ 00_ 000_ Page / 00_ 00_ XCC XCC Page / XCC XCC / General characteristics
More informationTechnical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection
0102 Model Number Features Direct mounting on standard actuators Compact and stable housing Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up to SIL2 acc. to IEC 61508 Accessories
More informationService Installation: 48 V Power Supply September 27, 2018 SI Written by BTA
Service Installation: 48 V Power Supply September 27, 2018 SI-92718 Written by BTA 48 Volt Power Supply Installation Guide PROCEDURE: Parts Needed: 48V Power Supply Kit Tools Needed: Standard screwdriver,
More informationMWR - MWF Metallized polyester film capacitor MKT - High performance
Main applications Blocking, filtering, bypassing, timing, coupling, decoupling, general applications in electronics. Low AC voltage motor running. Low power switching applications. Low pulse operation
More informationSonoMeter 30 Energy Meters
Data Sheet SonoMeter 30 Energy Meters Description The Danfoss SonoMeter 30 is a range of ultrasonic, compact energy meters intended for measuring energy consumption in heating and cooling applications
More informationHand lever valves VHER
Hand lever valves VHER Hand lever valves VHER Key features Powerful Flexible Practical -M- Flow 170 3800 l/min 4/3-way valve mid-position closed mid-position exhausted mid-position pressurised Connections:
More informationDifferential pressure controls, Type MP 54, 55 and 55A
MAKING MODERN LIVING POSSIBLE Technical brochure Differential pressure controls, Type MP 54, 55 and 55A MP 54 and oil pressure controls are used as safety switches to protect refrigeration compressors
More informationF series Foot Switches
F series Foot Switches ITC presents a complete line of foot switches from Bernstein, designed to respond to the most stringent requirements for machine control and safety applications. The F series includes
More informationSOLENOID VALVES AND PNEUMATIC VALVES
9 S E R I E S Electropneumatically and pneumatically operated valves Series 9 Assembly with sub-base (ISO 5599/1 Standards) Sizes 1, 2 and 3 The Series 9 electropneumatically or pneumatically operated
More information1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure
Siemens AG 204 Overview The pressure transmitter SITRANS P220 measures the gauge pressure of liquids, gases and vapors. Stainless steel measuring cell, fully welded Measuring ranges 2.5 to 600 bar (36.3
More informationXMPA12B2142 pressure sensor XMP - 12 bar - G 1/4 female - 2 NC - without control type
Characteristics pressure sensor XMP - 12 bar - G 1/4 female - 2 NC - without control type Main Range of product Pressure sensor type Pressure sensor name Pressure sensor size OsiSense XM Electromechanical
More informationPressure switches for air and water CS
Data sheet Pressure switches for air and water CS CS pressure switches have a built-in pressure operated, three-pole switch. The contact position of which depends on the pressure in the connector and the
More informationGEN20AD-GEN20AL-GEN18AN
AD-- Parts List 02-August-16 This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-ad--.pdf for the current revision. Standby Generators Table of Contents
More information1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI
Siemens AG 06 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure
More informationDSB, DSF: Pressure monitors and pressure switches
roduct data sheet 12.1 23.760 DSB, DSF: ressure monitors and pressure switches How energy efficiency is improved Control and monitoring according to needs and with no auxiliary energy. Features For regulating
More informationTURQUOISE SWITCHES ABJ (BJ) SWITCHES
Ultra-miniature Size Sealed Switches TURQUOISE SWITCHES ABJ (BJ) SWITCHES Terminal type Mounting hole 2.3 mm type FEATURES Ultra-miniature size, High sealing performance sealed switches Elastomer double
More informationPOWR-BLOKS Distribution/Splicer Blocks and Covers
SPECIFICATIONS Voltage : 600V erage: Based on NEC Table 310-16, using 75 C copper wire Material: Phenolic rated at 150 C and Thermoplastic rated at 125 C (LD1400 and LS1300 series only) : Standard: Highly
More information24 AWG Nano M8 Single Ended and Double Ended Assemblies
24 AWG M8 Single Ended and Double Ended Abrasion Chemicals Flexing UL Listed CSA IP68 Rated RoHS Compliant 300 V Operating Temperature Range -30 C to 90 C Current Rating: 4 Amps Cord sets made with Trex-Onics
More informationNAUTILUS Small pump. Powerful performance. Certified according to DIN 14425, submersible pumps for fire departments
NAUTILUS Small pump. Powerful performance. Certified according to DIN 14425, submersible pumps for fire departments The first choice for high water and flooding. Rosenbauer NAUTILUS submersible pump NAUTILUS.
More informationstepper motor 2-phase hybrid stepper motor (bipolar) high protection class with plug or stranded wires optional with encoder / brake
stepper motor 2-phase hybrid stepper motor (bipolar) high protection class with plug or stranded wires optional with / brake / 9 www.igus.de MOT-AN-S_EN_2070# part number (not configurable, only for illustration)
More informationDSL, DSH: Specially designed pressure limiter
Product data sheet 11.1 23.770 DSL, DSH: Specially designed pressure limiter How energy efficiency is improved Control and monitoring according to needs and with no auxiliary energy. Features Switching
More informationGas density monitor With integrated transmitter Model GDM-100-TI
SF 6 gas solutions Gas density monitor With integrated transmitter Model GDM-100-TI grid Products WIKA data sheet SP 60.05 for further approvals see page 5 Applications Gas density monitoring of closed
More informationItem No.: /
mounting types; for parallel or perpendicular mounting; pin spacing mm / 0197 in; 4-pole - Item No: 769- Male connector; with CAGE CLAMP connection and fixing flanges; for screw or similar mounting types;
More informationValve Proving System VDK 200 A S06*
Valve Proving System VDK 200 A S06* Valve proving system with the following approvals. UL Recognized File # MH17004 CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter
More informationValve Proving System VDK 200 A S02
Valve Proving System VDK 200 A S02 Valve proving system with the following approvals. UL Recognized File # MH17004 CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter
More informationFor Models: 55A00-2 (HAI UPB 1500W Wall Switch Dimmer) 55A00-3 (HAI UPB 2400W Wall Switch Dimmer) 37A00-1 (HAI Auxiliary Switch)
HAI UPB High Power Wall Switch Dimmer and HAI Auxiliary Switch Installation and Operating Instructions For Models: 55A00-2 (HAI UPB 1500W Wall Switch Dimmer) 55A00-3 (HAI UPB 2400W Wall Switch Dimmer)
More informationPressure Measurement Single-range transmitters for general applications
Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.
More informationInstallation & Maintenance Instructions TEC-11N TIMER. Analogue electronic timer 02/09
Installation & Maintenance Instructions TEC-11N TIMER Analogue electronic timer 02/09 GENERAL OPERATION The TEC-11N timer is produced using SMT (Surface Mounting Technology), ensuring improved performance
More informationCONTENTS TABLE OF MAIDA S HISTORY TERMINOLOGY & GENERAL SPECIFICATIONS. iii. LEAD CODES and TAPE & REEL STANDARD SERIES 1 HC SERIES 17
TABLE OF CONTENTS MAIDA S HISTORY TERMINOLOGY & GENERAL LEAD CODES and TAPE & REEL i ii iii STANDARD SERIES 1 HC SERIES 17 LOW PROFILE SERIES 33 THERMALLY PROTECTED SERIES 39 HIGH ENERGY SERIES LEAD CODES
More informationD I G I T A L C L A M
The MAXX Press D I G I T A L C L A M OPERATOR S MANUAL 6 x0 x5 5 x5 Safety Instructions When using your heat press, basic precautions should always be followed, including the following:.. 3.. 5. 6. 7.
More informationIntrinsically safe solenoid valves on/off controls - ATEX certification
www.atos.com Table E130-17/E Intrinsically safe solenoid valves on/off controls - ATEX certification valve body valve spool intrinsically safe solenoid electrical connector manual override DHW-0611/WP/6
More informationStand-Alone Bubble Detection System
Instruction Sheet P/N Stand-Alone Bubble Detection System 1. Introduction The Bubble Detection system is designed to detect air-bubble induced gaps in a bead of material as it is being dispensed. When
More informationDifferential Pressure Control Types MP 54, MP 55 and MP 55A
MAKING MODERN LIVING POSSIBLE Data sheet Differential Pressure Control Types MP 54, MP 55 and MP 55A MP 54 and MP 55 oil differential pressure controls are used as safety switches to protect refrigeration
More informationElectrical operating instructions
en Electrical operating instructions Door control panel TS 980 (Design and functions subject to change) 51171150 - b 07.2007 OPERATING AND INSTALLATION INSTRUCTIONS PAGE SAFETY DIRECTIONS...4 ENCLOSURE
More informationESE SERIES. Series Overview. Specifications
Series Overview + Compact Capsule Design + Fully Compliant With IEEE 802.3 Formats + 100Base-T / 1000Base-T Ethernet Cable + T568B Wiring Terminated With RJ45 Connectors + High Quality Gold on Gold Contacts
More informationInstallation, operating and maintenance Instructions for Seemag bypass level indicator
Issue: S Date: 05-09-14 Type G35 General information The Seetru bypass magnetic level indicator, abbreviate SEEMAG, serves to show the filling level of fluids in tanks, basins, tubes etc. The Seemag operates
More informationTightness controls TC 1 3 and TC 4
Tightness controls TC 1 3 and TC 4 Test of both safety valves Short test period thanks to logical decision-making in the program sequence Adjustable test period which can be adapted to different systems
More informationDifferential pressure switch MP 54, MP 55 and MP 55A
Data sheet Differential pressure switch MP 54, MP 55 and MP 55A MP 54 and MP 55 oil differential pressure switches are used as safety switches to protect refrigeration compressors against low lubricating
More informationSITRANS P measuring instruments for pressure
SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and
More informationEPP4 Pressure Regulator Basic G 1/4"
EPP4 Pressure Regulator Basic G 1/4" Flow Curve 1/4" Dimensions Outlet pressure - bar 9 8 7 6 5 4 3 2 1 0 0 20 40 60 70 80 100 120 Flow rate - Nm 3 /h The male connector adopted on the EPP4 is a standard
More informationHAI UPB 15A Relay Switch and Auxiliary Switch Installation and Operating Instructions
HAI UPB 15A Relay Switch and Auxiliary Switch Installation and Operating Instructions For the following Models: 40A00-1 HAI 15A Relay Switch (referred to as HAI UPB Wall Switch, in this document), and
More informationPressure Measurement Single-range transmitters for general applications
Siemens A 207 Overview Application The SITRANS P Compact pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials
More information