Certificate of Compliance
|
|
- Kory Glenn
- 5 years ago
- Views:
Transcription
1 Certificate of Compliance Certificate: Master Contract: Issued to: Brodie Meter Company, LLC Highway 301 North Statesboro, GA USA Attention: Jonathan Whitten The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US or with adjacent indicator 'US' for US only or without either indicator for Canada only. Issued by: Dorel Stefan Dorel Stefan PRODUCTS CLASS PROCESS CONTROL EQUIPMENT - For Hazardous Locations CLASS PROCESS CONTROL EQUIPMENT - For Hazardous Locations - Certified to US Standards Class I, Division 1, Groups C & D BiRotor Plus Models B271, B274, B281, B284 and B291 Volumetric Flow Meters; Rated 9-28Vdc, 5W Class 2; Ambient Temperature range -40 C to +60 C; Maximum Process Pressure for B271, B281 and B291 of 1964kPa (285psi) or for B274 and B284 of 5099kPa (740psi). Enclosure Type 4X/IP65, Temperature codes of T6 or T4 (high temperature process fluid model) Model code: Bxyz9abcdefghjk B=BiRotor Plus xy - Flow Rate 27=Std 425 US gpm/1609 lpm, intermittent 550 US gpm/2081 lpm, pipe size 3 28=Std 700 US gpm/2650 lpm, intermittent 1000 US gpm/3785, pipe size 4 DQD 507 Rev Page: 1
2 29=Std 1000 US gpm/3785 lpm, intermittent 1200 US gpm/4542 lpm, pipe size 6 z - Maximum Process Pressure - MWP 1=285psi 4=740psi (only options 27 and 28) 9 - Revision C=BiRotor Plus a - Meter Output Temperature of Process: -20 C to 75 C std A=One Pickoff w/dual Channel Preamp B= Two Pickoffs w/dual Channel Preamp C= One Pickoff only D=Two Pickoffs only Temperature of Process: -10 C to 110 C (High Temp.) E= One HT Pickoff w/dual Channel Preamp F= Two HT Pickoffs w/dual Channel Preamp G= One HT Pickoff only H= Two HT Pickoffs only b - Elastomers: Process Wetted Materials (any alpha character A-Z, not relevant to certification) c - Connection Type, Flange A=ANSI 150# B=ANSI 300# C=DIN PN 16 D=DIN PN 40 d - Accuracy/Flow Range (any alpha character A-Z, not relevant to certification) e - Rotors/Bearings (any alpha character A-Z, not relevant to certification) f - Additional Measurement A=none g - Weights and Measure Approvals (any alpha character A-Z, not relevant to certification) h - Hazardous Area Approvals B=USA and Canada (Class I Groups C and D) j - Additional Accessories - Register Mounting 1=none k - Material Certification and Pressure Documentation (any alpha character A-Z, not relevant to certification) DQD 507 Rev Page: 2
3 Low Temperature BiRotor Plus Models LB271, LB274, LB281, LB284 and LB291 Volumetric Flow Meters; Rated 9-28Vdc, 5W Class 2; Ambient Temperature range -40 C to +60 C; Maximum Process Pressure for LB271 LB281 and LB291 of 1964kPa (285psi) or for LB274 and LB284 of 5099kPa (740psi). Enclosure Type 4X/IP65, Temperature codes of T6. Model code: LBxyz9abcdefghjk LB=Low Temp BiRotor Plus xy - Flow Rate 27=Std 425 US gpm/1609 lpm, intermittent 550 US gpm/2081 lpm, pipe size 3 28=Std 700 US gpm/2650 lpm, intermittent 1000 US gpm/3785, pipe size 4 29=Std 1000 US gpm/3785 lpm, intermittent 1200 US gpm/4542 lpm, pipe size 6 z - Maximum Process Pressure - MWP 1=285psi 4=740psi (only options 27 and 28) 9 - Revision A=Low Temp BiRotor Plus a - Meter Output Temperature of process: -40 to 75 C A=One Pickoff w/dual Channel Preamp B= Two Pickoffs w/dual Channel Preamp C= One Pickoff only D=Two Pickoffs only b - Elastomers: Process Wetted Materials (any alpha character A-Z, not relevant to certification) c - Connection Type, Flange A=ANSI 150# B=ANSI 300# C=DIN PN 16 D=DIN PN 40 d - Accuracy/Flow Range (any alpha character A-Z, not relevant to certification) e - Rotors/Bearings (any alpha character A-Z, not relevant to certification) f - Additional Measurement A=none g - Weights and Measure Approvals (any alpha character A-Z, not relevant to certification) DQD 507 Rev Page: 3
4 h - Hazardous Area Approvals B=USA and Canada (Class I Groups C and D) j - Additional Accessories - Register Mounting 1=none k - Material Certification and Pressure Documentation (any alpha character A-Z, not relevant to certification) APPLICABLE REQUIREMENTS Canadian Requirements CSA Std C22.2 No 0-M91 CSA Std. C22.2 No CSA Std C22.2 No 30-M1986 CSA Std C22.2 No 142M1987 CSA Std C22.2 No CSA Std C22.2 No US Requirements ANSI/UL Std th Ed. ANSI/UL Std th Ed. ANSI/UL Std 50 12th Ed. ANSI/UL Std 50E 1st Ed. The following standard(s) were used in whole or in part as a guideline. IEC Ed. 2.1 NEMA MARKINGS General Requirements - Canadian Electrical Code, Part II Threaded Conduit Entries Explosion-Proof Enclosures for Use in Class Hazardous Locations Process Control Equipment Enclosures for Electrical Equipment, Non- Environmental Considerations Enclosures for Electrical Equipment, Environmental Considerations Industrial Control Equipment Explosion-Proof and Dust-Ignition-Proof Electrical Equipment For Use in Hazardous (Classified) Locations Enclosures for Electrical Equipment, Non- Environmental Considerations Enclosures for Electrical Equipment, Environmental Considerations Degree of Protection Provided by Enclosures (IP Code) Enclosures for Electrical Equipment (1000 Volts Maximum) The following markings are provided on multiple 300 series stainless steel painted, stamped and etched nameplates. The stainless steel plate is attached to the flow meter by means of two or four stainless steel drive screws. See drawings ENG , ENG , ENG , ENG and ENG submittor's name: Brodie Meter Co LLC or DBA Brodie International or CSA Master Contract Number xxxxxx, adjacent to the CSA Mark in lieu of manufacturers name. model designation: As specified in the PRODUCTS section above. electrical rating: As specified in the PRODUCTS section above. DQD 507 Rev Page: 4
5 maximum process pressure; As specified in the PRODUCTS section above. ambient temperature range: As specified in the PRODUCTS section above. Enclosure: As specified in the PRODUCTS section above. hazardous locations designations: As specified in the PRODUCTS section above. date code or equivalent; The CSA Mark with or without C and US indicators, as shown on the Certificate of Conformity. WARNING - TO PREVENT IGNITION OF HAZARDOUS ATMOSPHERE, DISCONNECT ALL SUPPLY CURCUITS, AND INSURE THE AREA IS NON-HAZARDOUS BEFORE OPENING, KEEP COVER TIGHTLY CLOSED WHEN IN OPERATION, CONDUIT SEALS MUST BE INSTALLED WITHIN 18 INCHES OF THE ENCLOSURE ADVERTISSEMENT: POUR EVITER D ENFLAMMER DES VAPEURS DANGEREUSES, COUPRI TOUTES LES ALIMENTATIONS ET S ASSURER QEU L EMPLACEMENT N EST PAS DANGEREREUX ANAVT D OUVRIR. PENDANT L UTILISATION, S ASSURER QUE LE COUVERCLE EST BIEN FERM. POSE DES RACCARDS DE SCELLEMENT AU PLUS 475 MM BOITER. Note - Jurisdictions in Canada may require these markings to also be provided in French language. It is the responsibility of the manufacturer to provide bilingual marking, where applicable, in accordance with the requirements of the Provincial Regulatory Authorities. It is the responsibility of the manufacturer to determine this requirement and have bilingual wording added to the "Markings". DQD 507 Rev Page: 5
Certificate of Compliance
Certificate of Compliance Certificate: 2419437 Master Contract: 203012 Issued to: ABB Automation Products GmbH 72 Schillerstrasse Minden, 32425 Germany Attention: Ralf Schaffer The products listed below
More informationCertificate of Compliance
FF0002 Certificate of Compliance Certificate: 70024080 Date Issued: 2017-07-04 Issued to: ecom instruments GmbH Industriestrasse 2 Assamstadt, Baden Wurttemburg 97959 GERMANY Attention: Kevin Spence The
More informationType N-10, N-11 Hazardous Area Non-incendive Transmitters
Electronic Pressure Catalog > Hazardous Area > N-10, N-11 Type N-10, N-11 Hazardous Area Non-incendive Transmitters Applications Natural gas compressors Wellhead monitoring Pipeline pressure General industrial
More informationI/P Transducer Positioner Module
I/P Transducer Positioner Module VRC P/N: 7958032 Installation, Operation and Maintenance Instructions 2.09 [53.1] 1.30 [32.9] 2.97 [75.5] 0.78 [19.8] 0.18 [4.4] 1.42 [36.1] n.18 MOUNTING HOLES (2) PLACES
More informationG196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve
Installation Instructions Issue Date March 13, 2013 G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Application The G196 valves are suitable for use with natural gas, Liquefied
More informationReg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS
Government Approved Test Laboratory (Previously AIA) Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS ZEST
More informationDual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure DMV-ZRD/612 Series DMV-ZRDLE/612 Series
Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure DMV-ZRD/612 Series DMV-ZRDLE/612 Series Two normally closed automatic shutoff valves in one housing. Valve 1 (V1) incorporates
More informationTorque Tube TB300 Digital Transmitters
Page 1 of 7 7E.300-E Issue 4-2009 Description Series TB300 torque tube liquid level instruments utilize the buoyancy exerted on a displacer when immersed in a liquid. The buoyancy on the displacer is proportional
More informationInstallation, Operation, & Maintenance Manual. MODEL: Watlow Controller P53 Direct, P53 Remote
Installation, Operation, & Maintenance Manual Mustang Sample Conditioning System MODEL: Watlow Controller P53 Direct, P53 Remote Conforms to UL STDS 61010-1 & 1203 Certified to CSA STD C22.2 Nos. 61010-1
More informationDual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure. DMV-ZRD/612 Series DMV-ZRDLE/612 Series
Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure DMV-ZRD/612 Series DMV-ZRDLE/612 Series Two normally closed automatic shutoff valves in one housing. Valve 1 (V1) incorporates
More informationPro-V Multivariable Flowmeter
Pro-V Multivariable Flowmeter Model M23 Insertion Meter M23-V flowmeter provides cost-effective volumetric flow monitoring solution for most liquids M23-VT incorporates temperature sensing to provide a
More informationNorth American Pressure Switches
Combustion North American Pressure Switches Bulletin 8757 Pressure switches are used with Automatic Shutoff Valves or Solenoid Valves to interrupt fuel flow in the event of fuel or air failure. They are
More informationDual Modular Safety Shutoff Valves with Proof of Closure. DMV-D/622 Series DMV-DLE/622 Series
Dual Modular Safety Shutoff Valves with Proof of Closure DMV-D/622 Series DMV-DLE/622 Series Two normally closed automatic shutoff valves in one housing. Valve 2 (V2) incorporates proof of closure. Each
More informationDual Modular Safety Shutoff Valve with NEMA 4x Enclosure. DMV-D/604L Series DMV-DLE/604L Series
Dual Modular Safety Shutoff Valve with NEMA 4x Enclosure DMV-D/604L Series DMV-DLE/604L Series Two normally closed automatic shutoff valves in one housing; each with the following approvals. UL Listed
More informationDual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11
Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11 Two normally closed safety shutoff valves in one housing; each with the following approvals. CSA Certified ANSI Z21.21 CSA 6.5 Marked C/I
More informationDual Modular Safety Shutoff Valves. DMV-D/11 Series DMV-DLE/11 Series
Dual Modular Safety Shutoff Valves DMV-D/11 Series DMV-DLE/11 Series Two normally closed safety shutoff valves in one housing; each with the following approvals. CSA Certified ANSI Z21.21 CSA 6.5 Marked
More informationSV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT. SV/614 Series SV-DLE/614 Series
SV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT SV/614 Series SV-DLE/614 Series Normally closed automatic shutoff valve with proof of closure and the following approvals. CSA Certified
More informationG196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve
Installation Instructions Issue Date August 19, 2008 G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Application The G196 valves are suitable for use with natural gas, Liquefied
More informationG96 Series BASOTROL Dual Operator Valve
Installation Instructions 9. Issue Date February 22, 2013 G96 Series BASOTROL Dual Operator Valve Applications The G96 valves are combination, dual operator, automatic valves available with or without
More informationDual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series
Dual Modular Safety Shutoff Valves DMV-D/602 Series DMV-DLE/602 Series Two normally closed safety shutoff valves in one housing; each with the following approvals. UL Recognized UL 429 File # MH16727 CSA
More informationField Certification Certificate of Compliance
1 Field Certification Certificate of Compliance Certificate: 2460594 Master Contract: 244849 Project: 2460594 Date Issued: 2011-12-23 Issued to: Sirio Sistemi Elettronici SpA Via Fleming 16 59100 Prato
More informationDual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series
Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure DMV-D/624L Series DMV-DLE/624L Series Two normally closed automatic shutoff valves in one housing. Valve 2 (V2) incorporates proof
More informationTurbine Flowmeters for Gas Applications (Metric)
Turbine Flowmeters for Gas pplications (Metric) Description Flow Technology s FT Series turbine flowmeters utilize a proven flow measurement technology to provide exceptionally reliable digital outputs.
More informationDual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11
Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11 Two normally closed safety shutoff valves in one housing; each with the following approvals. CSA Certified ANSI Z21.21 CSA 6.5 Marked C/I
More informationTechnical Data. Dimensions
0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications
More informationDimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm
Dimensions M30x1,5 5 40 37 0102 Model Number 36 LED Features Comfort series 10 mm embeddable Connection BN BU Accessories BF 30 Mounting flange, 30 mm L+ L- Technical Data specifications Switching element
More informationMLS Series Liquid Level Switches. Installation and Operations Manual Section 15
MLS Series Liquid Level Switches Installation and Operations Manual 00-02-0730 2012-11-11 Section 15 In order to consistently bring you the highest quality full featured products, we reserve the right
More informationDual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series
Dual Modular Safety Shutoff Valves DMV-D/602 Series DMV-DLE/602 Series Two normally closed safety shutoff valves in one housing; each with the following approvals. UL Recognized UL 429 File # MH16727 CSA
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 5 mm
00 Model Number Features 5 mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,
More informationDual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series
Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure DMV-D/624L Series DMV-DLE/624L Series Two normally closed automatic shutoff valves in one housing. Valve 2 (V2) incorporates proof
More informationDual Modular Safety Shutoff Valves with NEMA 4x Enclosure DMV-D 704/604 DMV-DLE 704/604
Dual Modular Safety Shutoff Valves with NEMA 4x Enclosure DMV-D 704/604 DMV-DLE 704/604 Two normally closed safety shutoff valves in one housing; each with the following approval. CSA Certified ANSI Z21.21
More informationMonitoring device NTS 30
P R O D U C T I N F O R M A T I O N Electronic level- and temperature monitoring device Monitoring device NTS 30 Contents Description Description... 2 Operating... 3 Design and electrical data... 4 Circuit
More informationKDV HIGH ACCURACY GLASS TUBE ROTAMETER
KDV HIGH ACCURACY GLASS TUBE ROTAMETER Flow Pressure Level Temperature measurement monitoring control S2 Industrial and Sanitary Designs Body Sizes 1/2 Through 2 Reliable, Time Proven Glass Tube Design
More informationBrooks TMF-Zone 1 Models 5816-Ex/5864-Ex
Data Sheet DS-TMF-586Ex-MFC-eng TMF-Zone Brooks TMF-Zone Models 586-Ex/5864-Ex Customer Benefits Assured process accuracy and repeatability Long-term reliability Reduced maintenance CE certified Improved
More informationCertificate of Compliance
Certificate of Compliance Certificate: 1127056 Master Contract: 154490 Issued to: Fisher Controls International LLC 205 S Center St Marshalltown, IA 50158 USA Attention: Daniel G. Moyer The products listed
More informationPRESSURE SWITCHES Bulletin 8757
PRESSURE SWITCHES Bulletin 8757 September 2013 Pressure switches are used with Automatic Shutoff Valves or solenoid valves to interrupt fuel fl ow in the event of fuel or air failure. They are also used
More informationCertificate of Compliance
FF0 002 Certificate of Compliance Certificate: 1714037 (LR) Issued to: Emerson Process Management GmbH & Co. OHG Industriestrasse 1 Hasselroth, 63594 GERMANY Attention: Gabriele Blendin The products listed
More informationDual Modular Safety Shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634
Dual Modular Safety Shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634 Two normally closed automatic shutoff valves in one housing.
More informationPressure Measurement Single-range transmitters for general applications
Siemens A 207 Overview Application The SITRANS P Compact pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 1.5 mm
0102 Model Number Features 1.5 mm flush Accessories BF 8 Mounting flange, 8 mm Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 1.5 mm Installation flush
More informationOperating Instructions
LPL Series LED Pendant Lighting Operating Instructions IM0102 COOPER Electronic Technologies (Shanghai) Co., Ltd. No. 955 Shengli Road, East Area of Zhangjiang High-Tech Park, Shanghai 201201 China 1.
More informationTechnical Data. Dimensions
0102 Model Number Features 10 mm flush Shielded PUR cable for oil and gas sector Accessories BF 30 Mounting flange, 30 mm Technical Data specifications Switching function Normally closed (NC) Output type
More informationDual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series
Dual Modular Safety Shutoff Valves with Two-stage operation DMV-ZRD/602 Series DMV-ZRDLE/602 Series Two normally closed automatic shutoff valves in one housing; each with the following approvals. UL Recognized
More informationPT-400 User Manual APG
PT-400 User Manual APG R Doc #9002825 Rev D1, 11/17 Table of Contents Introduction... iii Warranty Statement... iv Chapter 1: Specifications and Options... 1 Dimensions...1 Specifications... 2 Model Number
More informationModel 10. Low-Medium Pressure Reducing Regulator
Model 10 Low-Medium Pressure Reducing Regulator General Specifications & Performance Characteristics The Model 10 is a pressure reducing regulator useful in a wide variety of applications. The Model 10
More informationZ, Y, and X PURGE INDICATORS / CONTROLLERS
PurgEx XXXXXX Z, Y, and X PURGE INDICATORS / CONTROLLERS PURGE / PRESSURIZATION PURGE / PRESSURIZATION XXXXX XXXXXXXXX 8626 SERIES Globally Certified Z,Y,X Purge Indicators / Controllers and Accessories
More informationDual Modular Safety shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634
Dual Modular Safety shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634 Two normally closed automatic shutoff valves in one housing.
More informationSPECIFICATIONS ATTENTION
VPS 504 S06 Installation Manual - P/N 80122 - Ed. 01/09 VPS 504 S06 and S05 Valve Proving System Installation Instructions VPS 1 6 Gases Natural gas, air and other inert gases. NOT suitable for butane
More informationMooney * Noise Controller Installation, Operation, and Maintenance Manual
GE Oil & Gas Mooney * Noise Controller Installation, Operation, and Maintenance Manual imagination at work Scope This manual provides instructions for installation, operation and maintenance of the Mooney
More informationValve Proving System VDK 200 A S02
Valve Proving System VDK 200 A S02 Valve proving system with the following approvals. UL Recognized File # MH17004 CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter
More informationCERTIFICATE OF COMPLIANCE
FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 02062 USA T: 781 762 4300 F: 781-762-9375 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL
More informationG92 Series BASOTROL Automatic Pilot Gas Valve
Installation Instructions Issue Date September 17, 2008 G92 Series BASOTROL Automatic Pilot Gas Valve Installation IMPORTANT: Only qualified personnel should install or service BASO Gas Products. These
More informationTechnical Data. Dimensions
00 Model Number Features mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,
More informationValve Proving System VDK 200 A S06*
Valve Proving System VDK 200 A S06* Valve proving system with the following approvals. UL Recognized File # MH17004 CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter
More informationWallace & Tiernan Flow Measurement Equipment
Water Technologies Wallace & Tiernan Flow Measurement Equipment Glass Tube Varea-Meter Units Features Rugged, One-Piece Enclosure The welded, deep-formed frame is heavy gauge 302 stainless steel. It protects
More informationPanaFlow MV82. Insertion Style Multivariable Flowmeter. GE Measurement & Control. Key Benefits. Applications
GE Measurement & Control PanaFlow MV82 Insertion Style Multivariable Flowmeter Key Benefits Multivariable vortex flowmeter for measuring volumetric flow, temperature, pressure, density, and mass flow using
More information9700 Transmitter Submersible hydrostatic level transmitter
Specification sheet IP0078 October 2007 Level 9700 Transmitter Submersible hydrostatic level transmitter Description The 9700 series hydrostatic level transmitter is designed to perform in the most arduous
More informationTurbine Flowmeters for Gas Applications
Turbine Flowmeters for Gas Applications Description Flow Technology s FT Series turbine flowmeters utilize a proven flow measurement technology to provide exceptionally reliable digital outputs. Because
More informationDual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series
Dual Modular Safety Shutoff Valves with Two-stage operation DMV-ZRD/602 Series DMV-ZRDLE/602 Series Two normally closed automatic shutoff valves in one housing; each with the following approvals. UL Recognized
More informationPressure Automated Calibration Equipment
GE Measurement & control Pressure Automated Calibration Equipment Safety Instructions and User Guide - K0447 PACE5000 PACE6000 K0447 Issue No. 9 1 10 1 PACE5000 1 2 3 4 5 PACE6000 2 6 7 8 3 4 5 6 7 8 9
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx CML 14.0034X Issue No:
More informationSafety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85
XA01537F-A/00/EN/01.16 71333275 Products Solutions Services Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85 0Ex ia IIC T6 Ga X Ga/Gb Ex ia IIC T6 X Document: XA01537F-A Safety instructions
More informationFILTER, REGULATOR AND FILTER/REGULATOR Stainless Steel 316L Compact 1/4, High Flow 1/4-1/2
FILTER, REGULATOR AND FILTER/REGULATOR Stainless Steel L Compact /, High Flow / - / Air service equipment Series FEATURES Stainless Steel filter, regulator and filter regulator intended for corrosive environment
More informationTurbine Flowmeters for Gas Applications
Turbine Flowmeters for Gas Applications Description Flow Technology s FT Series turbine flowmeters utilize a proven flow measurement technology to provide exceptionally reliable digital outputs. Because
More informationTechnical Data. Dimensions
0102 Model Number Features Comfort series 15 mm non-flush Stainless steel housing Accessories BF 30 Mounting flange, 30 mm Technical Data specifications Switching element function NAMUR, NC Rated operating
More informationRE: PROPANE SYSTEM & REGULATOR TESTING/INSPECTION PROCEDURE
March 22, 2013 RE: PROPANE SYSTEM & REGULATOR TESTING/INSPECTION PROCEDURE Regulators: Symptom: Pressure Drop Cause: External leaks detected at pigtail hose MPT fitting connection(s) to regulator body
More informationNorth American Simplex Basket Strainers for Gas and Oil
Combustion North American Simplex Basket Strainers for Gas and Oil A mesh lining (304 stainless standard or 316 stainless or monel special), either 20, 40 or 100 mesh, can be provided, depending on the
More informationANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS
Procedure-assembly-functional test and performance requirements 1 SCOPE 1.1 This document establishes the general procedure for assembly, functional testing and normal performance requirements of low Series
More informationFlow Measurement Equipment Armored Purge Meters
Flow Measurement Equipment Armored Purge Meters Features & Key Benefits Accurate Gas Metering A snubber on the float causes readings to steady out quickly, gives true readings down to atmospheric pressures.
More informationHomestead Series 820 AWWA Butterfly Valves
Homestead Series 820 AWWA Butterfly Valves Dependable Valves for Water & Wastewater Service BODY: The ductile iron body meets or exceeds the design strength requirements of the AWWA C504 standards. Flange
More informationASSE International Product (Seal) Listing Program
ASSE International Product (Seal) Listing Program ASSE 1070-2015 / ASME A112.1070-2015 / CSA B125.70-15 Performance Requirements for Water Temperature Limiting Devices Manufacturer: Contact Person: E-mail:
More informationGOST R CERTIFICATION SYSTEM FEDERAL AGENCY OF TECHNICAL REGULATION AND METROLOGY CERTIFICATE OF CONFORMITY
CERTIFICATE OF CONFORMITY No. ROSS US.GB05.V03061 Valid from 8/12/2010 through 8/12/2013 No. 0422555 CERTIFICATION AGENCY ROSS RU.0001.11GB05 NONPROFIT INDEPENDENT RESEARCH ORGANIZATION (), CERTIFICATION
More informationPro-V Multivariable Flowmeter Model M22 In-line Vortex
Pro-V Multivariable Flowmeter Model M22 In-line Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,
More informationRCD - Ultra-Rugged Differential Pressure Flowmeter
0.15-1 to 85-600 GPM Liquids 2.5-25 to 300-1700 SCFM Gases 1/2 to 3 Line Sizes Bronze or 316-Ti Stainless Steel Mechanical Indicator, Digital Indicator, Transmitters and Switches Available Custom Calibrations
More informationGas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series
Gas Appliance Pressure Regulators with integrated gas filter FRI/6 Series CSA Certified ANSI Z21.18 / CSA 6.3 Gas Appliance Pressure Regulator File # 1135455 EU Gas Appliance Directive EN 88 CE-0087 AU
More informationTwo-Wire In Situ Oxygen Analyzer (550 to 1400 C)
Product Data Sheet PDS 106-581.A01 March, 2004 Model 5081FG Two-Wire In Situ Oxygen Analyzer (550 to 1400 C) Intrinsically safe: - CENELEC EEx ia IIC - Class I Div. I Gr. B, C, D (pending) Operates at
More informationSingle-Phase Pad-Mounted Distribution. Single-Phase Pad-Mounted Distribution Transformers KVA
62-10 Single-Phase Pad-Mounted Distribution Catolog Transformers Section Howard Industries, Inc. Certifi ed to ISO 9001:2015 62-10 Single-Phase Pad-Mounted Distribution Transformers 5-500 KVA 10002179
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-10
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well
More informationKDV HIGH ACCURACY GLASS TUBE ROTAMETER
KDV HIGH ACCURACY GLASS TUBE ROTAMETER Flow Pressure Level Temperature measurement monitoring control S2 Industrial and Sanitary Designs Body Sizes 1/2 Through 2 Reliable, Time Proven Glass Tube Design
More informationAmerican Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM
American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM ASSE STANDARD #1048 - REVISED: 2009 Double Check Detector Fire Protection Backflow Prevention Assemblies Separate, complete laboratory
More informationAmerican Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM
American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM ASSE STANDARD #1003 - REVISED: 2009 Water Pressure Reducing Valves for Domestic Water Distribution Systems MANUFACTURER: CONTACT
More informationAir Eliminators and Combination Air Eliminators Strainers
Description Air Eliminators and Combination Air Eliminator Strainers are designed to provide separation, elimination and prevention of air in piping systems for a variety of installations and conditions.
More informationPipe Thread Connection 1/2 inch NPT. Friction Loss Refer to Figure 3
Worldwide Contacts www.tyco-fire.com Model B-1 Pipe Line Strainer General Description The Model B-1 Pipe Line Strainers (Ref. Figures 1 and 2) are designed for installation in the water supply connection
More informationDimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm
Dimensions M18x1 37 40 4 0102 24 LED Model Number Features 5 mm embeddable Usable up to SIL2 acc. to IEC 61508 Connection BN BU Accessories L+ L- EXG-18 Quick mounting bracket with dead stop BF 18 Mounting
More informationLevel transmitter LT 100
KROHNE 09/2001 7.02363.21.00 GR/PRINTO Level transmitter LT 100 Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters
More informationSimple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18
The Bray Simple Set Max is a flanged pressure independent control (PIC) valve designed for a wide variety of hot water and chilled water control applications. The SSM Series combines high rangeability
More informationSafety Shutoff Valves MVD/6 Series MVDLE/6 Series
Safety Shutoff Valves /6 Series /6 Series Normally closed safety shutoff valve with the following approvals. UL Listed UL 49 File # MH16 CSA Certified ANSI Z1.1 CSA 6. Marked C/I File # LR 111 FM Approved
More information1213B2 Service Regulators Maximum Inlet Pressure 125 PSIG
SB-8506. B Service Regulators Maximum Inlet Pressure 5 PSIG Measurement Engineers Since 86 www.americanmeter.com B Service Regulators General Information The American Meter Series B pressure regulator
More informationPressure Switch for gas and air GGAO-A4
Pressure Switch for gas and air GGAO-A4 CSA Certified CSA C22.2 No. LR 53222 Certification file # 201527 Commonwealth of Massachusetts Approved Product Approval code G3-0106-191 Gas pressure switch Codes
More informationOPTIBAR P 1010 C Technical Datasheet
Technical Datasheet Pressure transmitter with recessed diaphragm for general applications Wide variety thanks to modular design Measuring ranges up to 250 bar / 3750 psi High overload and temperature stability
More informationP/N: IND-DP Industrial Drum Pumps
P/N: IND-DP-0613 Industrial Drum Pumps Multi-Certified Industrial SAFETY Solutions SAFETY: As a leading pump manufacturer, Standard is known for our commitment to product quality and SAFETY serving the
More informationThe evolution of the Ex-proof flame path
April 2017 The evolution of the Ex-proof flame path As written in previous dissertation, the most critical part of a flameproof enclosure 'Ex d' is the flame path. Although the Standards are divided into
More informationPT-400 User Manual APG
PT-400 User Manual APG R Doc #9002825 Rev C, 09/14 Table of Contents Introduction... iii Warranty and Warranty Restrictions... iv Chapter 1: Specifications and Options... 1 Dimensions...1 Specifications...
More informationGas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series
Gas Appliance Pressure Regulators with integrated gas filter FRI/6 Series CSA Certified ANSI Z21.18 / CSA 6.3 Gas Appliance Pressure Regulator File # 1135455 EU Gas Appliance Directive EN 88 CE-0087 AU
More informationFor Multi-Parameter Meters see mvx
Design Features VORTEX IN-LINE FLOW METERS For Multi-Parameter Meters see m Principles of Operation n No moving parts to wear or fail. n Electronics can be remotely mounted up to 30.5 m (0 ft). n No fluid
More informationTechnical Data. Dimensions
0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable
More informationTechnical Data. General specifications. Rated operating distance s n 5 mm
0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS For Burner Kit replacement of 553010021 Burners in GUI, GDI & GNI Gas Furnaces Using Natural Gas Please read these instructions completely before attempting installation. SAFETY
More informationTechnical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection
0102 Model Number Features Direct mounting on standard actuators Compact and stable housing Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up to SIL2 acc. to IEC 61508 Accessories
More informationModels EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations
Models EXN and OLG Certified. Not Modified. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations General Description Industrial Climate Engineering s (ICE) EXN and OLG pressurization
More information