Level Measurement Point level measurement - Vibrating switches

Size: px
Start display at page:

Download "Level Measurement Point level measurement - Vibrating switches"

Transcription

1 Overview Configuration Horizontal mounting Switching point (recommended mounting position, particularly for adhesive applications) Marked with screwed version on top, with flange versions directed to the flange holes Vertical mounting is a standard vibrating level switch for material detection in liquid and slurry applications such as overflow, high, low, and demand applications, as well as pump protection. For use in SIL- applications. Benefits Proven vibrating level switch technology for liquids Compact insertion length of 0 mm (.57 inch) for confined space applications Fault monitoring for corrosion, loss of vibration or line break to the piezo drive Functional Safety (SIL ). Device suitable for use in accordance with IEC 6508 and IEC 65 Hygienic process connections Suitable for API 350 Optional remote test signal conditioner Switching point [approx. 3 (0.5)] Mount away from filling openings or agitators. Switching point with higher density Switching point with lower density Switching point [approx. 7 (.06)] Application is a level switch designed for industrial use in all areas of process technology and can be used with liquids and slurries. With a tuning fork insertion length of only 0 mm (.57 inch), can be mounted in small pipes and applications with confined space. The LVL00 can be used to measure products with a minimum density of > 0.5 g/cm³ (0.08 lb/in³). The LVL00 can be used in difficult conditions including turbulence, air bubbles, foam generation, buildup, or external vibration. continuously monitors faults via frequency evaluation, providing early detection of strong corrosion or damage on the tuning fork, loss of vibration, or a line break to the piezo drive. The tuning fork is piezoelectrically energized and vibrates at its mechanical resonance frequency of approximately 00 Hz. The vibration frequency changes when the tuning fork is covered by the medium. This change is detected by the integrated oscillator and converted into a switching command. The integrated electronics evaluate the level signal and output a switching signal, directly operating connected devices. The optional signal conditioner provides a remote test feature to ensure continuous product reliability. Key Applications: for use in liquids and slurries, for level measurement, overfill, and dry run protection Moisture protection NOTE: Welded socket for flush mount optional installation, dimensions in mm (inch) Ensure cable gland faces downward to avoid water ingress. Siemens FI 0 Update /07 /7

2 Technical specifications Mode of operation Measuring principle Input Measured variable Output Output options Vibrating point level switch High and low and demand (via mode switch) Relay output (DPDT), floating SPDTs Contactless electronic switch -wire Namur signal output Transistor (NPN/PNP) V DC 8/6 ma Measuring accuracy Repeatability 0. mm (0.00 inch) Hysteresis Approx. mm (0.08 inch) with vertical installation Switching delay Approx. 500 ms (on/off) Frequency Approx. 00 Hz Rated operating conditions Installation conditions Location Indoor/outdoor Ambient conditions Ambient temperature C ( F) Installation category III Pollution degree Medium conditions Temperature - LVL00S Standard C ( F) - LVL00S High temperature option C ( F) - LVL00E Standard: with C ( F) 36L/Hastelloy - LVL00E High temperature option: C ( F) with 36L/Hastelloy Pressure (vessel) bar g ( psi g) Density g/cm³ ( lb/in³); g/cm³ ( lb/in³) by switching over Design Material Enclosure Aluminum die-cast AISi0Mg, powder-coated, basis: Polyester Stainless steel housing, electropolished 36L 36L (.0 or.35), Hastelloy 36L (.0 or.35), Hastelloy Tuning fork Extension tube [ø.3 mm (0.839 inch)] Process connection: threaded 36L (.0 or.35), Hastelloy Process connection: flange 36L (.0 or.35), 36L with Hastelloy, ECTFE, or PFA coating Process seal Klingersil C-00 Process connection Pipe thread, cylindrical (ISO 8 T) G ¾" A, G " A Pipe thread, tapered ¾" NPT, " NPT, ½" NPT Flanges DIN from DN5, ASME from " Hygienic fittings Bolting DN 0 PN 0,, ½,, ½" Tri-Clamp PN 0, conus DN 5 PN 0, Tuchenhagen Varivent DN 50 PN 0, SMS Degree of protection Conduit entry Weight Device weight (dependent on process fitting) Tube extension (extended version) Power supply Supply voltage Relay DPDT Contactless -wire NAMUR Operating voltage (characteristics according to standard) for connection to an amplifier according to NAMUR Type X/NEMA X/IP66/IP67 x M0 x.5 (cable: ø mm), x blind stopper M0 x.5; attached x M0 x.5 cable entry x ½" NPT cable entry, x blind stopper ½" NPT, x ½" NPT cable entry x M x ; x blind stopper M0 x.5 Approx kg ( lb) Approx. 90 g/m (0 oz/ft) V AC, 50/60 Hz, V DC [at U > 60 V DC] V AC, 50/60 Hz, V DC IEC , approx. 8. V Off-load voltage U o approx. 8. V Short-circuit current I U approx. 8. ma Power consumption... 8 VA (AC), approx..3 W (DC) Relay DPDT... 8 VA (AC), approx..3 W (DC) Contactless Domestic current requirement approx. 3 ma (via load circuit) Load current Min. 0 ma Max. 00 ma [with I > 300 ma the ambient temperature can be max. 60 C (0 F)] Max. A up to 0 ms (not WHG specified) 8/6 ma, two-wire output Output signal Empty (uncovered) -8 ma Full (covered) -6 ma Fault message - <.8 ma Possible signal conditioning instruments: SITRANS SCSC, SITRANS TCSC -wire Namur Current consumption Falling characteristics.6 ma uncovered/ 0.6 ma covered 0.6 ma uncovered/.6 ma covered Failure message 0.6 ma Transistor (NPN/PNP) V DC Output Floating transistor output, permanently shortcircuit-proof Load current < 00 ma Voltage loss < V Switching voltage <55VDC Blocking current <0 A /7 Siemens FI 0 Update /07

3 Certificates and approvals CE, CSA Overfill Protection WHG and VLAREM II FM (Non-Incendive) Class I, Div., Groups A, B, C, D FM (Explosion-Proof) Class I, Div., Groups A, B, C, D; (Dust Ignition- Proof) Class II, III, Div., Groups E, F, G IECEx d IIC T6... T Ga/Gb EHEDG ATEX II /G, G EEx d IIC T6 ATEX II G, /G, G EEx ia IIC T6 Shipping approvals BR-Ex d IIC T6... T FDA, 3A, Ehedge SIL/IEC6508 Declaration of Conformity [SIL- (min/max detection)] Please see configuration section below for full list of approvals., Standard 7ML576- in liquid and slurry applications such as over A 0 flow, high, low, and demand applications, as well as pump protection. For use in SIL- and hazardous applications. Click on the for the online configuration in the PIA Life Cycle Portal. Electronics Contactless electronic switch V AC/DC )9)) Double relay (DPDT) V DC/ V AC ) NAMUR signal 9) Transistor (NPN/PNP) V DC )5) 5 Two-wire (8/6 ma) V DC 6 Approvals Without approvals A Overfill protection (WHG) 9) B ATEX II G, /G, G Ex ia IIC T6 + WHG 6)9) C ATEX II /G, G Ex d IIC T6 + WHG 5)5) D ATEX II G, /G, G Ex ia IIC T6 + shipping E approvals 6)6) ATEX II /G, G Ex d IIC T6 + shipping F approvals 5)5) ATEX II G, /G, G Ex ia IIC T6 + ATEX II / D G IP6X T 6)7)7) IECEx Ex ia IIC T6 6)8) H Shipping approvals 6) K ATEX II 3G Ex na II T5...T X )9) L FM (IS) Class I, II, III, Div., Groups A, B, C, D, E, F, N G 6)0) FM (XP) Class I, Div., Groups A, B, C, D; (DIP) P Class II, III, Div., Groups E, F, G )5)0) FM (NI) Class I, Div., Groups A, B, C, D ) Q IECEx d IIC T6... T Ga/Gb 5)5) R CSA (XP) Class I, II, III Div., S Groups A,B, C, D, E, F, G 5)5) CSA(NI)Class I, II, III, Div., T Groups A, B, C, D, E, F, G ) BR-Ex d IIC T6... T 5)3) U CSA (IS) Class I, II, III Div., V Groups A, B, C, D, E, F, G 6)9) ATEX II G, /G, G Ex ia IIC T6 6) W Process connection Thread G¾" A, PN 6/36L A 0 0 Thread G¾" A, PN 6/36L Ra < 0.8 µm A 0 Thread ¾" NPT, PN 6/36L A 0 Thread ¾" NPT, PN 6/36L Ra < 0.8 µm A 0 3 Thread ¾" NPT, PN 6/Alloy 00 (.360) A 0 Thread G¾" A, PN 6/Alloy C (.60) A 0 5 Thread ¾" NPT, PN 6/Alloy C (.60) A 0 6 Thread G" A, PN 6/36L A 0 7 Thread G" A, PN 6/36L ECTFE coated MB98 ) A 0 8 Thread G" A, PN 6/ 36L PFA coated ) A 0 Thread G" A, PN 6/ Alloy 00 (.360) A Thread G" A, PN 6/ 36L Ra < 0.8 µm A Thread " NPT, PN 6/ 36L A 3 Thread " NPT, PN 6/ 36L ECTFE coated MB98 ) A Thread " NPT, PN 6 / 36L PFA-coated ) A 5 Thread " NPT, PN 6 / Alloy 00 (.360) A 6 Thread " NPT, PN 6 / 36L Ra < 0.8 µm A 7 Thread G" A, PN 6 / Alloy C (.60) A 8 Thread G" A, PN 6/Alloy C (.60) A 0 Ra < 0.3 µm Thread G½" A, PN 6/36L A Thread G½" A, PN 6/36L Ra < 0.8 µm A Thread G½" A, PN 6/Alloy C (.60) A 3 Siemens FI 0 Update /07 /73

4 , Standard 7ML576- in liquid and slurry applications such as overflow, A 0 high, low, and demand applications, as well as pump protection. For use in SIL- and hazardous applications. Thread " NPT, PN 6/Alloy C (.60) A Thread ½" NPT, PN 6/36L A 5 Thread ½" NPT, PN 6/36L Ra < 0.8 µm A 6 Thread ½" NPT, PN 6/Alloy C (.60) A 7 Thread G" A, PN 6/36L A 8 Thread M7 x.5, PN 6/36L A 3 0 Conus DN 5, PN 0/36L Ra < 0.3 µm A 3 Conus DN 5, PN 0/36L Ra < 0.8 µm A 3 Conus DN 5, PN 0/ECTFE (ZB3033) ) A 3 3 Conus M5, PN 0/36L A 3 Conus M5, PN 0/36L Ra < 0.3 µm A 3 5 Conus M5, PN 0/36L Ra < 0.8 µm A 3 6 Tri-Clamp ", PN 6/36L Ra < 0.3 µm A 3 7 Tri-Clamp ", PN 6/Alloy C (.60) A 3 8 Tri-Clamp ", PN 6/36L Ra < 0.8 µm A 0 Tri-Clamp ½", PN 6/36L Ra < 0.3 µm A Tri-Clamp ½", PN 6/Alloy C (.60) A Tri-Clamp ½", PN 6/36L Ra < 0.8 µm A 3 Tri-Clamp ", PN 6/36L Ra < 0.3 µm A Tri-Clamp ", PN 6/Alloy C (.60) A 5 Tri-Clamp ", PN 6/36L Ra < 0.8 µm A 6 Tri-Clamp ½", PN 0/36L Ra < 0.3 µm A 7 Tri-Clamp ½", PN 0/36L Ra < 0.8 µm A 8 Tri-Clamp 3", PN 0/36L Ra < 0.3 µm A 5 0 Tri-Clamp 3", PN 0/36L Ra < 0.8 µm A 5 Bolting DN 3, PN 0 DIN85/36L Ra < 0.3 µm A 5 Bolting DN 3, PN 0 DIN85/36L Ra < 0.8 µm A 5 3 Bolting DN 5, PN 0 DIN85/36L Ra < 0.3 µm A 5 Bolting DN 5, PN 0 DIN85/36L Ra < 0.8 µm A 5 5 Bolting DN 0, PN 0 DIN85/36L Ra < 0.3 µm A 5 6 Bolting DN 0, PN 0 DIN85/36L Ra < 0.8 µm A 5 7 Bolting DN 0, PN 0 DIN86- A/36L A 5 8 Ra < 0.8 µm ZB305 Bolting DN 50, PN 5 DIN85/36L Ra < 0.3 µm A 6 0 Bolting DN 50, PN 5 DIN85/36L Ra < 0.8 µm A 6 Bolting DN 50, PN 5 DIN86- A/36L A 6 Ra < 0.8 µm ZB305 Hygienic w. compr. nut F0, PN 5/36L A 6 3 Hygienic w. compr. nut F0, PN 5/36L A 6 Ra < 0.3 µm Hygienic w. compr. nut F0, PN 5/36L A 6 5 Ra < 0.8 µm Varivent N50-0/36L Ra < 0.3 µm A 6 6 Varivent N50-0/36L Ra < 0.8 µm A 6 7 Varivent N5/00/36L Ra < 0.8 µm A 6 8 DRD flange, PN 0/36L ZB3007 A 7 0 SMS DN 38/36L Ra < 0.8 µm ) A 7 SMS DN 5, PN 6/36L Ra < 0.8 µm ) A 7 Swagelok VCR screwing ZG579, PN 6/36L A 7 3 Neumo biocontrol size 5, PN 6/36L Ra < 0.8 µm A 7 Neumo biocontrol size 50, PN 6/36L Ra < 0.8 µm ) A 7 5 Neumo biocontrol size 65, PN 6/36L Ra < 0.8 µm A 7 6 Neumo biocontrol size 80, PN 6/36L Ra < 0.8 µm A 7 7 SÜDMO DN 50, PN 0/36L Ra < 0.8 µm A 7 8 Small flange DN 5, PN.5 DIN 803/36L pol. A 8 0 Ra < 0.8 µm Small flange DN 0, PN.5 DIN 803/36L pol. A 8 Ra < 0.8 µm Ingold connection, PN6 / 36 A 8 L Ra < 0.8 µm (acc. to MB53), Standard 7ML576- in liquid and slurry applications such as overflow, A 0 high, low, and demand applications, as well as pump protection. For use in SIL- and hazardous applications. Ingold connection, PN 6/Alloy C (.60) A 8 3 Ra < 0.8 µm (acc. to MB607) Terminal DN 33.7 PN 0 DIN86-3-A-/36L BN Ra < 0.8 µm ) A 8 Hygienic fl. DN 50 PN 6 DIN86--A-/36L A 8 5 Ra < 0.8 µm Flange DN 5, PN 6 Form C, DIN 50/36L A 8 6 Flange DN 5, PN 6 Form C, DIN 50/PFA ) A 8 7 Flange DN 5, PN 0 Form C, DIN 50/36L A 8 8 Flange DN 5, PN 0 Form C, DIN 50/ B 0 0 Alloy C (.60) Flange DN 5, PN 0 Form C, DIN 50/ECTFE ) B 0 Flange DN 5, PN 0 Form C, DIN 50/PFA ) B 0 Flange DN 5, PN 0 Form C, DIN 50/Enamelled B 0 3 Flange DN 5, PN 0 Form D, DIN 50/36L B 0 Flange DN 5, PN 0 Form F, DIN 50/36L B 0 5 Flange DN 5, PN 0 Form N, DIN 50/36L B 0 6 Flange DN 5, PN 0 Form N, DIN 50/ B 0 7 Alloy C (.60) Flange DN 5, PN 0 Form N, DIN 50/ B 0 8 Alloy 00 (.360) solid Flange DN 5, PN 0 V3, DIN 50/36L B 0 Flange DN 3, PN 0 Form C, DIN 50/36L B Flange DN 3, PN 0 Form C, DIN 50/ECTFE ) B Flange DN 0, PN 6 Form C, DIN 50/36L B 3 Flange DN 0, PN 6 Form C, DIN 50/ECTFE ) B Flange DN 0, PN 0 Form C, DIN 50/36L B 5 Flange DN 0, PN 0 Form C, DIN 50/ B 6 Alloy C (.60) Flange DN 0, PN 0 Form C, DIN 50/ECTFE ) B 7 Flange DN 0, PN 0 Form C, DIN 50/PFA ) B 8 Flange DN 0, PN 0 Form C, DIN 50/ Enamelled 3) B 0 Flange DN 0, PN 0 Form F, DIN 50/36L B Flange DN 0, PN 0 Form N, DIN 50/36L B Flange DN 0, PN 0 Form E, DIN 50/36L B 3 Flange DN 0, PN 0 V3, DIN 50/36L B Flange DN 50, PN 0 Form C, DIN 50/36L B 5 Flange DN 50, PN 0 Form C, DIN 50/ B 6 Alloy C (.60) Flange DN 50, PN 0 Form C, DIN 50/ECTFE ) B 7 Flange DN 50, PN 0 Form C, DIN 50/ ECTFE (ZB308) ) B 8 Flange DN 50, PN 0 Form C, DIN 50/PFA ) B 3 0 Flange DN 50, PN 0 Form D, DIN 50/36L B 3 Flange DN 50, PN 0 Form D, DIN 50/ B 3 Alloy C (.60) Flange DN 50, PN 0 Form F, DIN 50/36L B 3 3 Flange DN 50, PN 0 Form N, DIN 50/36L B 3 Flange DN 50, PN 0 Form N, DIN 50/ B 3 5 Alloy C (.60) Flange DN 50, PN 0 Form E, DIN 50/36L B 3 6 Flange DN 50, PN 0 V3, DIN 50/36L B 3 7 Flange DN 50, PN 0 R3, DIN 50/36L B 3 8 Flange DN 50, PN 6 Form F, DIN 50/36L B 0 Flange DN 50, PN 6 Form N, DIN 50/ B Alloy C (.60) Flange DN 50, PN 6 Form C, DIN 50/36L B Flange DN 50, PN 6 Form L, DIN 50/36L B 3 Flange DN 50, PN 00 Form E, DIN 50/36L B Flange DN 50, PN 00 Form L, DIN 50/36L B 5 Flange DN 65, PN 0 Form C, DIN 50/36L B 6 /7 Siemens FI 0 Update /07

5 , Standard in liquid and slurry applications such as overflow, high, low, and demand applications, as well as pump protection. For use in SIL- and hazardous applications. 7ML A 0 Flange DN 65, PN 0 Form C, DIN 50/ B 7 Alloy C (.60) Flange DN 65, PN 0 Form C, DIN 50/ECTFE ) B 8 Flange DN 65, PN 0 Form C, DIN 50/PFA ) B 5 0 Flange DN 65, PN 0 Form F, DIN 50/36L B 5 Flange DN 65, PN 6 Form E, DIN 50/36L B 5 Flange DN 80, PN 0 Form C, DIN 50/36L B 5 3 Flange DN 80, PN 0 Form C, DIN 50/ B 5 Alloy C (.60) Flange DN 80, PN 0 Form C, DIN 50/ECTFE ) B 5 5 Flange DN 80, PN 0 Form C, DIN 50/PFA ) B 5 6 Flange DN 80, PN 0 Form C, DIN 50/ Enamelled 3) B 5 7 Flange DN 80, PN 0 Form F, DIN 50/36L B 5 8 Flange DN 80, PN 0 Form N, DIN 50/36L B 6 0 Flange DN 00, PN 6 Form C, DIN 50/36L B 6 Flange DN 00, PN 6 Form C, DIN 50/ B 6 3 Alloy C (.60) Flange DN 00, PN 6 Form C, DIN 50/ECTFE ) B 6 Flange DN 00, PN 6 Form C, DIN 50/PFA ) B 6 5 Flange DN 00, PN 6 Form C, DIN 50/ Enamelled 3) B 6 6 Flange DN 00, PN 6 Form D, DIN 50/36L B 6 7 Flange DN 00, PN 6 Form F, DIN 50/36L B 6 8 Flange DN 00, PN 6 Form N, DIN 50/36L B 7 0 Flange DN 00, PN 0 Form C, DIN 50/36L B 7 Flange DN 00, PN 0 Form C, DIN 50/ECTFE ) B 7 Flange DN 00, PN 0 Form C, DIN 50/PFA ) B 7 3 Flange DN 00, PN 0 Form C, DIN 50/ Enamelled 3) B 7 Flange DN 00, PN 0 Form F, DIN 50/36L B 7 5 Flange DN 00, PN 0 Form N, DIN 50/36L B 7 6 Flange DN 00, PN 0 V3, DIN 50/36L B 7 7 Flange DN 00, PN 6 Form E, DIN 50/36L B 7 8 Flange DN 00, PN 00 Form E, DIN 50/36L B 8 0 Flange DN 00, PN 00 Form L, DIN 50/36L B 8 Flange DN 5, PN 6 Form F, DIN 50/36L B 8 Flange DN 5, PN 0 Form C, DIN 50/36L B 8 3 Flange DN 5, PN 0 Form N, DIN 5/ 36L B 8 Flange DN 50, PN 6 Form C, DIN 50/36L B 8 5 Flange DN 50, PN 6 Form C, DIN 50/ B 8 6 Alloy C (.60) Flange DN 50, PN 6 Form C, DIN 50/ECTFE ) B 8 7 Flange DN 50, PN 6 Form C, DIN 50/PFA ) B 8 8 Flange DN 50, PN 6 Form D, DIN 50/36L C 0 0 Flange DN 50, PN 0 Form C, DIN 50/36L C 0 Flange DN 50, PN 0 Form C, DIN 50/ C 0 Alloy C (.60) Flange DN 50, PN 0 Form F, DIN 50/36L C 0 3 Flange DN 50, PN 0 Form N, DIN 5/36L C 0 Flange DN 00, PN 0 Form C, DIN 50/ECTFE ) C 0 5 Flange DN 00, PN 6 Form C, DIN 50/36L C 0 6 Flange DN 5, PN 0 Form B, EN 09-/36L C 0 7 Flange DN 5, PN 0 Form B, EN 09-/ C 0 8 Alloy C (.60) Flange DN 5, PN 0 Form B, EN/ 36L/ PFA ) C 0 Flange DN 5, PN 0 Form B, EN 09-/ Enamelled 3) C Flange DN 5, PN 0 Form B, EN 09-/36L C Flange DN 5, PN 0 Form F, EN 09-/36L C 3 Flange DN 5, PN 63 Form B, EN 09-/36L C, Standard 7ML576- in liquid and slurry applications such as overflow, A 0 high, low, and demand applications, as well as pump protection. For use in SIL- and hazardous applications. Flange DN 5, PN 00 Form B, EN 09-/36L C 5 Flange DN 0, PN 0 Form B, EN/ 36L C 6 Flange DN 0, PN 0 Form B, EN 09-/PFA ) C 7 Flange DN 0, PN 0 Form B, EN/36L C 8 Flange DN 50, PN 0 Form B, EN/36L C 0 Flange DN 50, PN 0 Form B, EN 09-/ C Alloy C (.60) Flange DN 50, PN 0 Form B, EN 09-/ C Alloy 00 (.360) ZB977 Flange DN 50, PN 0 Form B, EN 09-/ECTFE ) C 3 Flange DN 50, PN 0 Form B, EN/ 36L/PFA ) C Flange DN 50, PN 0 Form B, EN 09-/ Enamelled 3) C 5 Flange DN 50, PN 0 Form C, EN 09-/36L C 6 Flange DN 50, PN 0 Form D, EN/36L C 7 Flange DN 50, PN 0 Form D, EN 09-/ C 8 Alloy C (.60) Flange DN 50, PN 0 Form B, EN 09-/36L C 3 0 Flange DN 50, PN 0 Form E, EN 09-/36L C 3 Flange DN 80, PN 0 Form B, EN 09-/36L C 3 Flange DN 80, PN 0 Form B, EN 09-/ C 3 3 Alloy C (.60) Flange DN 80, PN 0 Form B, EN 09-/ECTFE ) C 3 Flange DN 80, PN 0 Form B, EN 09-/ Enamelled 3) C 3 5 Flange DN 80, PN 0 Form B, EN 09-/36L C 3 6 Flange DN 00, PN 6 Form B, EN 09-/36L C 3 7 Flange DN 00, PN 6 Form B, EN 09-/ C 3 8 Alloy C (.60) Flange DN 00, PN 6 Form B, EN 09-/ Enamelled 3) C 0 Flange DN 00, PN 0 Form B, EN 09-/36L C Flange DN 00, PN 0 Form B, EN 09-/ Enamelled 3) C Flange DN 00, PN 0 Form C, EN 09-/36L C 3 Flange DN 00, PN 63 Form B, EN 09-/36L C Flange DN 50, PN 6 Form B, EN 09-/36L C 5 Flange DN 50, PN 6 Form B, EN 09-/PFA ) C 6 Flange DN 50, PN 0 Form B, EN 09-/36L C 7 Flange DN 50, PN 0 Form B, EN 09-/ECT- FE ) C 8 Flange DN 50, PN 0 Form B, EN 09-/36L C 5 0 Flange " 50 lb ASME B6.5/36L C 5 Flange " 50 lb RF, ASME B6.5/Alloy C C 5 (.60) Flange " 50 lb RF, ASME B6.5/Alloy 00 (.360) C 5 3 ZB977 Flange " 50 lb RF, ASME B6.5/ECTFE ) C 5 Flange " 50 lb RF, ASME B6.5/PFA ) C 5 5 Flange " 50 lb RF, ASME B6.5/Enamelled 3) C 5 6 Flange " 300 lb RF, ASME B6.5/36L C 5 7 Flange " 300 lb RF, ASME B6.5/ECTFE ) C 5 8 Flange " 600 lb RF, ASME B6.5/36L C 6 0 Flange ½" 50 lb RF, ASME B6.5/36L C 6 Flange ½" 50 lb RF, ASME B6.5/ C 6 Alloy C (.60) Flange ½" 50 lb RF, ASME B6.5/ECTFE ) C 6 3 Flange ½" 50 lb RF, ASME B6.5/PFA ) C 6 Flange ½" 50 lb RF, ASME B6.5 Enamelled 3) C 6 5 Flange ½" 50 lb FF, ASME B6.5/ECTFE ) C 6 6 Flange ½" 300 lb RF, ASME B6.5/36L C 6 7 Siemens FI 0 Update /07 /75

6 , Standard in liquid and slurry applications such as overflow, 7ML A 0 high, low, and demand applications, as well as pump protection. For use in SIL- and hazardous applications. Flange ½" 300 lb RF, ASME B6.5/ C 6 8 Alloy 00 (.360) ZB977 Flange ½" 300 lb RF, ASME B6.5/ECTFE 3) C 7 0 Flange ½" 600 lb RF, ASME B6.5/36L C 7 Flange " 50 lb RF, ASME B6.5/36L C 7 Flange " 50 lb RF, ASME B6.5/Alloy C C 7 3 (.60) Flange " 50 lb RF, ASME B6.5/Alloy 00 (.360) C 7 ZB977 Flange " 50 lb RF, ASME B6.5/ECTFE ) C 7 5 Flange " 50 lb RF, ASME B6.5/PFA ) C 7 6 Flange " 50 lb RF, ASME B6.5/Enamelled 3) C 7 7 Flange " 50 lb FF, ASME B6.5/36L C 7 8 Flange " 50 lb FF, ASME B6.5/ECTF ) C 8 0 Flange " 50 lb SG (small groove), C 8 ASME B6.5/36L Flange " 300 lb RF, ASME B6.5/36L C 8 Flange " 300 lb RF, ASME B6.5/Alloy C C 8 3 (.60) Flange " 300 lb RF, ASME B6.5/ECTFE ) C 8 5 Flange " 300 lb RF, ASME B6.5/PFA ) C 8 6 Flange " 300 lb RF, ASME B6.5 Enamelled 3) C 8 7 Flange " 300 lb RJF, ASME B6.5/36L C 8 8 Flange " 300 lb ST, ASME B6.5/36L D 0 0 Flange " 300 lb LG (large groove), D 0 ASME B6.5/36L Flange " 300 lb LT, ASME B6.5/36L D 0 Flange " 600 lb RF, ASME B6.5/36L D 0 3 Flange " 600 lb RF, ASME B6.5/Alloy 00 (.360) D 0 ZB977 Flange " 600 lb RF, ASME B6.5/ECTFE ) D 0 5 Flange " 600 lb RJF, ASME B6.5/36L D 0 6 Flange " 600 lb LG, ASME B6.5/36L D 0 7 Flange " 900 lb RJF, ASME B6.5/36L D 0 8 Flange ½" 50 lb RF, ASME B6.5/36L D 0 Flange ½" 300 lb RF, ASME B6.5/36L D Flange 3" 50 lb RF, ASME B6.5/36L D Flange 3" 50 lb RF, ASME B6.5/Alloy C D 3 (.60) Flange 3" 50 lb RF, ASME B6.5/ECTFE ) D Flange 3" 50 lb RF, ASME B6.5/PFA ) D 5 Flange 3" 50 lb RF, ASME B6.5/Enamelled 3) D 6 Flange 3" 50 lb FF, ASME B6.5/36L D 7 Flange 3" 50 lb FF, ASME B6.5/ECTFE ) D 8 Flange 3" 50 lb FF, ASME B6.5/PFA ) D 0 Flange 3" 300 lb RF, ASME B6.5/36L D Flange 3" 300 lb RF, ASME B6.5/Alloy C D (.60) Flange 3" 300 lb RF, ASME B6.5/ECTFE ) D 3 Flange 3" 300 lb RF, ASME B6.5/PFA ) D Flange 3" 300 lb RF, ASME B6.5/Enamelled 3) D 5 Flange 3" 600 lb RF, ASME B6.5/36L D 6 Flange 3½" 50 lb RF, ASME B6.5/36L D 7 Flange 3½" 50 lb RF, ASME B6.5/ECTFE ) D 8 Flange " 50 lb RF, ASME B6.5/36L D 3 0 Flange " 50 lb RF, ASME B6.5/Alloy C D 3 (.60) Flange " 50 lb RF, ASME B6.5/ECTFE ) D 3 Flange " 50 lb RF, ASME B6.5/PFA ) D 3 3 Flange " 50 lb RF, ASME B6.5/Enamelled 3) D 3, Standard in liquid and slurry applications such as overflow, 7ML A 0 high, low, and demand applications, as well as pump protection. For use in SIL- and hazardous applications. Flange " 50 lb LT, ASME B6.5/36L D 3 5 Flange " 300 lb RF, ASME B6.5/36L D 3 6 Flange " 300 lb RF, ASME B6.5/Alloy C D 3 7 (.60) Flange " 300 lb RF, ASME B6.5/ECTFE ) D 3 8 Flange " 300 lb RJF, ASME B6.5/36L D 0 Flange " 300 lb LG, ASME B6.5/36L D Flange " 300 lb LT, ASME B6.5/36L D Flange " 600 lb RF, ASME B6.5/36L D 3 Flange " 600 lb RJF, ASME B6.5/36L D Flange 6" 50 lb RF, ASME B6.5/36L D 5 Flange 6" 50 lb RF, ASME B6.5/Alloy C D 6 (.60) Flange 6" 50 lb RF, ASME B6.5/ECTFE ) D 7 Flange 6" 50 lb RF, ASME B6.5/PFA ) D 8 Flange 6" 50 lb RJF, ASME B6.5/36L D 5 0 Flange 6" 300 lb RF, ASME B6.5/36L D 5 Flange 8" 50 lb RF, ASME B6.5/36L D 5 Flange 8" 50 lb RF, ASME B6.5/ECTFE ) D 5 3 Flange " BS.0 Table E/36L D 5 Flange " BS.0 Table E/PFA ) D 5 5 Flange ½" BS.0 Table E/36L D 5 6 Flange 3½" BS.0 Table E/36L D 5 7 Flange " BS.0 Table E/ECTFE ) D 5 8 Flange DN 0 0K, JIS/36L D 6 0 Flange DN 50 0K, JIS/36L D 6 Flange DN 80 0K, JIS/36L D 6 Flange DN 00 0K, JIS/36L D 6 3 Thread R PN 6, EN 06-/36L D 6 5 Flange " 900 lb RF, ASME B6.5/36L D 7 0 Adapter/Process temperature Without adapter/ C ( F) With adapter/ C ( F) 3) With adapter/ C ( F) 3 With gas-tight leadthrough/ C ( F) With gas-tight leadthrough/ C 5 ( F) Housing/Cable entry Aluminum IP66/IP67/M0 x.5 A Aluminum IP66/IP67/½" NPT B 36L stainless steel (electropolished) C IP66/IP67/M0 x.5 36L stainless steel (electropolished) D IP66/IP67/½" NPT Plastic single chamber IP66/IP67/M0 x.5 E Plastic single chamber IP66/IP67/½" NPT F Stainless steel chamber (precision casting) G IP66/IP67/M0 x.5 Stainless steel chamber (precision casting) H IP66/IP67/½" NPT Aluminum IP66/IP67/M0 x.5 Special HARTING V plug (bent) according to Tier One (ZB7555) ) /76 Siemens FI 0 Update /07

7 Further designs Order code.-factory certificate for material (EN 00) 8) Order code C5 Please add "-Z" to and specify Order code(s). Switching status indication with colors red-green ) Cleaning including Certificate (oil, grease, and silicone free) A W0 Functional Safety (SIL ). Device suitable for use in C0 accordance with IEC 6508 and IEC 65 8) Dye penetration test, results confirmed via a C3 3. certificate/instrument (EN00) 8) X-ray test + 3. certificate/instrument 8) C Identification label (measurement loop) stainless steel: max. 0 characters, add in plain text. To add more than one line, use a coma ","" for line break. Identification Label (measurement loop) foil: max. 0 characters add in plain text. To add more than one line, use a coma "," for line break. NACE075 to 3. Material Certificate for material (EN00 NACE MR 075) 8) Note: not available with Process Connection and Rigid extension coatings PFA, ECTFE, and Enamel. NACE not available with Hygienic process connections. Y7 Y8 D07 Positive material identification test + 3. certificate/instrument 8) C6 Roughness test + 3. certificate/instrument 8) C8 3.-Inspection Certificate for instrument with test C5 data (EN 00) Quality and test plan C6 Pressure test + 3. certificate/instrument 8) C3 Helium leak test + 3. certificate/instrument 8) C3 Ferrite measuring accuracy to DIN certificate/instrument 8) C60 Pressure test according to Norsok + 3. certificate/instrument 8) C6 Operating Instructions All literature is available to download for free, in a range of languages, at processinstrumentation/documentation Spare Parts and Accessories Electronics module Relay 7ML830-NC Electronics module Contactless 7ML930-6AA NAMUR spare electronics module A5E LVL00 Threaded Welded Socket G¾" A/36L with FKM Seal 7ML930-EE G" A/36L with FKM Seal 7ML930-EF M7 x.5/36l with FKM Seal 7ML930-EG G¾" A/36L with EPDM Seal 7ML930-EH G" A/36L with EPDM Seal 7ML930-EJ M7 x.5/36l with EPDM Seal 7ML930-EK ) Available only with Adapter/Process temperature options, 3,, and 5. ) Available only with Housing/Protection/Cable option B. 3) Available only with Adapter/Process Temperature options,, and. ) Not available with Adapter/Process Temperature options, 3, and 5. 5) Not available with Adapter/Process Temperature options,, and 5. 6) Available only with Electronics options and 6. 7) Not available with ECTFE coated probe options. 8) Listed Certificates are not available with all configurations please contact factory for more information. 9) Not available with Housing/Protection/Cable Option V. 0) Not available with PFA and ECTFE coating options. ) Available only with Approval option A. ) Available only with Relay Electronic options and Non-hazardous Approval options. 3) Available only with Enamelled Process connection options. ) Available only with Electronic options, 5, and 6. 5) Available only with Aluminum Housing/Protection/Cable options. 6) Not available with Stainless Steel (electropolished) Housing/Protection/Cable options and certain glands. 7) Not available with Plastic and Stainless Steel (electropolished) Housing/Protection/Cable options and certain glands. 8) Not available with Housing/Protection/Cable options D, and V. 9) Not available with Plastic Housing/Protection/Cable options and certain glands. 0) Not available with Housing/Protection/Cable options A, E, G, and V. ) Available only with Housing/Protection/Cable options B, D, F, and H. ) Not available with Housing/Protection/Cable options C and V. 3) Available only with Housing/Protection/Cable options A, B, and H. ) Not available with Approval options C, E, G, H, L, N, V, and W. 5) Not available with Approval options C, E, G, H, N, V, and W. Siemens FI 0 Update /07 /77

8 , Rigid extension in liquid applications such as overflow, high, 7ML low, and demand applications, as well as pump protection. For use in SIL- and hazardous applications. Click on the for the online configuration in the PIA Life Cycle Portal. Electronics Contactless electronic switch V AC/DC )9)) Double relay (DPDT) V DC/ V AC ) NAMUR signal 9) Transistor (NPN/PNP) V DC )5) 5 Two-wire (8/6 ma) V DC 6 Approvals Without approvals A Overfill protection (WHG) 9) B ATEX II G, /G, G Ex ia IIC T6 + WHG 6)9) C ATEX II /G, G Ex d IIC T6 + WHG 5)7)6) D ATEX II G, /G, G Ex ia IIC T6 + shipping E approvals 6)7) ATEX II /G, G Ex d IIC T6 + shipping approvals F 5)7)6) ATEX II G, /G, G Ex ia IIC T6 + ATEX II /D G IP6X T 6)8)8) IECEx Ex ia IIC T6 6)9) H Shipping approvals 7) K ATEX II 3G Ex na II T5... T X 8) L FM (IS) Class I, II, III, Div., Groups A, B, C, D, E, F, G 6)0) N FM (XP) Class I, Div., Groups A, B, C, D; (DIP) P Class II, III, Div., Groups E, F, G )5) FM (NI) Class I, Div., Groups A, B, C, D ) Q IECEx d IIC T6... T Ga/Gb 5)7)6) R CSA(XP) Class I,II,III Div., S Groups A, B, C, D, E, F, G )5)7) CSA(NI)Class I,II,III, Div., T Groups A, B, C, D, E, F, G ) BR-Ex d IIC T6... T 5)8) U CSA (IS) Class I, II, III Div., V Gruppen A, B, C, D, E, F, G 6)9) ATEX II G, /G, G Ex ia IIC T6 6) W NOTE: When selecting a Process connection option, process connection coating must match the extension coating and the material and surface roughness type. Process connection Thread G¾" A, PN 6/36L A 0 0 Thread G¾" A, PN 6/36L Ra < 0.8 µm A 0 Thread ¾" NPT, PN 6/36L A 0 Thread ¾" NPT, PN 6/36L Ra < 0.8 µm A 0 3 Thread ¾" NPT, PN 6/Alloy 00 (.360) A 0 Thread G¾" A, PN 6/Alloy C (.60) A 0 5 Thread ¾" NPT, PN 6/Alloy C (.60) A 0 6 Thread G" A, PN 6/36L A 0 7 Thread G" A, PN 6/36L ECTFE coated MB98 ) A 0 8 Thread G" A, PN 6/36L PFA coated ) A 0 Thread G" A, PN 6/Alloy 00 (.360) A Thread G" A, PN 6/36L Ra < 0.8 µm A 3 Thread " NPT, PN 6/36L A Thread " NPT, PN 6/36L ECTFE coated MB98 ) A 5 Thread " NPT, PN 6/36L PFA coated ) A 6 Thread " NPT, PN 6/Alloy 00 (.360) A 7 Thread " NPT, PN 6/36L Ra < 0.8 µm A 8 Thread G" A, PN 6/Alloy C (.60) A 0, Rigid extension in liquid applications such as overflow, high, 7ML low, and demand applications, as well as pump protection. For use in SIL- and hazardous applications. Thread G½" A, PN 6/36L A Thread G½" A, PN 6/36L Ra <0.8 µm A Thread G½" A, PN 6/Alloy C (.60) A 3 Thread " NPT, PN 6/Alloy C (.60) A Thread ½" NPT, PN 6/36L A 5 Thread ½" NPT, PN 6/36L Ra< 0.8 µm A 6 Thread ½" NPT, PN 6/Alloy C (.60) A 7 Thread G" A, PN 6/36L A 8 Thread M7 x.5 PN 6/36L A 3 0 Cyl. socket/36ti/.58 ECTFE coated ZB98 ) A 3 Conus DN 5 PN 0/36L Ra < 0.3 µm A 3 Conus DN 5 PN 0/36L Ra < 0.8 µm A 3 3 Conus DN 5 PN 0/ECTFE (ZB3033) ) A 3 Conus M5 PN 0/36L A 3 5 Conus M5 PN 0/36L Ra < 0.3 µm A 3 6 Conus M5 PN 0/36L Ra < 0.8 µm A 3 7 Tri-Clamp " PN 6/36L Ra < 0.3 µm A 3 8 Tri-Clamp " PN 6/Alloy C (.60) A 0 Tri-Clamp " PN 6/36L Ra < 0.8 µm A Tri-Clamp ½" PN 6/36L Ra < 0.3 µm A Tri-Clamp ½" PN 6/Alloy C (.60) A 3 Tri-Clamp ½" PN 6/36L Ra < 0.8 µm A Tri-Clamp " PN 6/36L Ra < 0.3 µm A 5 Tri-Clamp " PN 6/Alloy C (.60) A 6 Tri-Clamp " PN 6/36L Ra < 0.8 µm A 7 Tri-Clamp ½" PN 0/36L Ra < 0.3 µm A 8 Tri-Clamp ½" PN 0/36L Ra < 0.8 µm A 5 0 Tri-Clamp 3" PN 0/36L Ra < 0.3 µm A 5 Tri-Clamp 3" PN 0/36L Ra < 0.8 µm A 5 Bolting DN 3 PN 0 DIN85/36L Ra < 0.3 µm A 5 3 Bolting DN 3 PN 0 DIN85/36L Ra < 0.8 µm A 5 Bolting DN 5 PN 0 DIN85/36L Ra < 0.3 µm A 5 5 Bolting DN 5 PN 0 DIN85/36L Ra < 0.8 µm A 5 6 Bolting DN 0 PN 0 DIN85/36L Ra < 0.3 µm A 5 7 Bolting DN 0 PN 0 DIN85/36L Ra < 0.8 µm A 5 8 Bolting DN 0 PN 0 DIN86- A/36L A 6 0 Ra < 0.8 µm ZB305 Bolting DN 50 PN 5 DIN85/36L Ra < 0.3 µm A 6 Bolting DN 50 PN 5 DIN85/36L Ra < 0.8 µm A 6 Bolting DN 50 PN 5 DIN86- A/36L A 6 3 Ra < 0.8 µm ZB305 Hygienic w.compr.nut F0 PN 5/36L A 6 Hygienic w.compr.nut F0 PN 5/36L Ra < 0.3 µm A 6 5 Hygienic w.compr.nut F0 PN 5/36L Ra < 0.8 µm A 6 6 Varivent N50-0/36L Ra < 0.3 µm A 6 7 Varivent N50-0/36L Ra < 0.8 µm A 6 8 Varivent N5/00/36L Ra < 0.8 µm A 7 0 DRD flange PN 0/36L ZB3007 A 7 SMS DN 38/36L Ra < 0.8 µm ) A 7 SMS DN 5 PN 6/36L Ra < 0.8 µm ) A 7 3 Swagelok VCR screwing ZG579 PN 6/36L A 7 Neumo biocontrol size 5 PN 6/36L Ra < 0.8 µm A 7 5 Neumo biocontrol size 50 PN 6/36L Ra < 0.8 µm A 7 6 SÜDMO DN 50 PN 0/36L Ra < 0.8 µm A 8 0 Small flange DN 5 PN.5 DIN 803/36L pol. A 8 Ra<0.8 µm Small flange DN 0 PN.5 DIN 803/36L pol. A 8 Ra<0.8 µm Ingold connection PN 6/36L Ra < 0.8 µm A 8 3 /78 Siemens FI 0 Update /07

9 , Rigid extension in liquid applications such as overflow, high, low, and demand applications, as well as pump protection. For use in SIL- and hazardous applications. 7ML Collar clamp connection DN33,7 PN0 Form A, A 8 DIN86-3/.35 (BN, Ra < 0.8 µm) Collar flange DN50 PN6 Form A, DIN86-/ A L (Ra < 0.8 µm) Flange DN 5 PN 6 Form C, DIN 50/36L A 8 6 Flange DN 5 PN 6 Form C, DIN 50/PFA ) A 8 7 Flange DN 5 PN 0 Form C, DIN 50/36L A 8 8 Flange DN 5 PN 0 Form C, DIN 50/ B 0 0 Alloy C (.60) plated Flange DN 5 PN 0 Form C, DIN 50/ECTFE ) B 0 Flange DN 5 PN 0 Form C, DIN 50/PFA ) B 0 Flange DN 5 PN 0 Form D, DIN 50/36L B 0 3 Flange DN 5 PN 0 Form F, DIN 50/36L B 0 Flange DN 5 PN 0 Form N, DIN 50/36L B 0 5 Flange DN 5 PN 0 Form N, DIN 50/ B 0 6 Alloy C (.60) plated Flange DN 5 PN 0 Form N, DIN 50/ B 0 7 Alloy 00 (.360) solid Flange DN 5 PN 0 V3, DIN 50/36L B 0 8 Flange DN 3 PN 0 Form C, DIN 50/36L B 0 Flange DN 3 PN 0 Form C, DIN 50/ECTFE ) B Flange DN 0 PN 6 Form C, DIN 50/36L B Flange DN 0 PN 6 Form C, DIN 50/ECTFE ) B 3 Flange DN 0 PN 0 Form C, DIN 50/36L B Flange DN 0 PN 0 Form C, DIN 50/ B 5 Alloy C (.60) plated Flange DN 0 PN 0 Form C, DIN 50/ECTFE ) B 6 Flange DN 0 PN 0 Form C, DIN 50/PFA ) B 7 Flange DN 0 PN 0 Form C, DIN 50/Enamelled 3) B 8 Flange DN 0 PN 0 Form F, DIN 50/36L B 0 Flange DN 0 PN 0 Form N, DIN 50/36L B Flange DN 0 PN 0 Form E, DIN 50/36L B Flange DN 0 PN 0 V3, DIN 50/36L B 3 Flange DN 50 PN 0 Form C, DIN 50/36L B Flange DN 50 PN 0 Form C, DIN 50/ B 5 Alloy C (.60) plated Flange DN 50 PN 0 Form C, DIN 50/ECTFE ) B 6 Flange DN 50 PN 0 Form C, DIN 50/ECTFE (ZB308) ) B 7 Flange DN 50 PN 0 Form C, DIN 50/PFA ) B 8 Flange DN 50 PN 0 Form D, DIN 50/36L B 3 0 Flange DN 50 PN 0 Form D, DIN 50/ B 3 Alloy C (.60) Flange DN 50 PN 0 Form F, DIN 50/36L B 3 Flange DN 50 PN 0 Form N, DIN 50/36L B 3 3 Flange DN 50 PN 0 Form N, DIN 50/ B 3 Alloy C (.60) solid Flange DN 50 PN 0 Form E, DIN 50/36L B 3 5 Flange DN 50 PN 0 V3, DIN 50/36L B 3 6 Flange DN 50 PN 0 R3, DIN 50/36L B 3 7 Flange DN 50 PN 6 Form F, DIN 50/36L B 3 8 Flange DN 50 PN 6 Form N, DIN 50/ B 0 Alloy C (.60) plated Flange DN 50 PN 6 Form C, DIN 50/36L B Flange DN 50 PN 6 Form L, DIN 50/36L B Flange DN 50 PN 00 Form E, DIN 50/36L B 3 Flange DN 50 PN 00 Form L, DIN 50/36L B Flange DN 65 PN 0 Form C, DIN 50/36L B 5 Flange DN 65 PN 0 Form C, DIN 50/ B 6 Alloy C (.60) plated, Rigid extension in liquid applications such as overflow, high, 7ML low, and demand applications, as well as pump protection. For use in SIL- and hazardous applications. Flange DN 65 PN 0 Form C, DIN 50/ECTFE ) B 7 Flange DN 65 PN 0 Form C, DIN 50/PFA ) B 8 Flange DN 65 PN 0 Form F, DIN 50/36L B 5 0 Flange DN 65 PN 6 Form E, DIN 50/36L B 5 Flange DN 80 PN 0 Form C, DIN 50/36L B 5 Flange DN 80 PN 0 Form C, DIN 50/ B 5 3 Alloy C (.60) plated Flange DN 80 PN 0 Form C, DIN 50/ECTFE ) B 5 Flange DN 80 PN 0 Form C, DIN 50/PFA ) B 5 5 Flange DN 80 PN 0 Form F, DIN 50/36L B 5 6 Flange DN 80 PN 0 Form N, DIN 50/36L B 5 7 Flange DN 80 PN 0 Form N, DIN 50/ B 5 8 Alloy C (.60) plated Flange DN 00 PN 6 Form C, DIN 50/36L B 6 0 Flange DN 00 PN 6 Form C, DIN 50/ B 6 Alloy C (.60) plated Flange DN 00 PN 6 Form C, DIN 50/ECTFE ) B 6 Flange DN 00 PN 6 Form C, DIN 50/PFA ) B 6 3 Flange DN 00 PN 6 Form D, DIN 50/36L B 6 Flange DN 00 PN 6 Form F, DIN 50/36L B 6 5 Flange DN 00 PN 6 Form N, DIN 50/36L B 6 6 Flange DN 00 PN 0 Form C, DIN 50/36L B 6 7 Flange DN 00 PN 0 Form C, DIN 50/ECTFE ) B 6 8 Flange DN 00 PN 0 Form C, DIN 50/PFA ) B 7 0 Flange DN 00 PN 0 Form C, DIN 50/ Enamelled 3) B 7 Flange DN 00 PN 0 Form F, DIN 50/36L B 7 Flange DN 00 PN 0 Form N, DIN 50/36L B 7 3 Flange DN 00 PN 0 V3, DIN 50/36L B 7 Flange DN 00 PN 6 Form E, DIN 50/36L B 7 5 Flange DN 00 PN 00 Form E, DIN 50/36L B 7 6 Flange DN 00 PN 00 Form L, DIN 50/36L B 7 7 Flange DN 5 PN 6 Form F, DIN 50/36L B 7 8 Flange DN 5 PN 0 Form C, DIN 50/36L B 8 0 Flange DN 5 PN 0 Form N, DIN 5/36L B 8 Flange DN 50 PN 6 Form C, DIN 50/36L B 8 Flange DN 50 PN 6 Form C, DIN 50/ B 8 3 Alloy C (.60) plated Flange DN 50 PN 6 Form C, DIN 50/ECTFE ) B 8 Flange DN 50 PN 6 Form C, DIN 50/PFA ) B 8 5 Flange DN 50 PN 6 Form D, DIN 50/36L B 8 6 Flange DN 50 PN 0 Form C, DIN 50/36L B 8 7 Flange DN 50 PN 0 Form C, DIN 50/ B 8 8 Alloy C (.60) plated Flange DN 50 PN 0 Form F, DIN 50/36L C 0 0 Flange DN 50 PN 0 Form N, DIN 5/36L C 0 Flange DN 00 PN 0 Form C, DIN 50/ECTFE ) C 0 Flange DN 00 PN 6 Form C, DIN 50/36L C 0 3 Flange DN 5 PN 0 Form B, EN 09-/36L C 0 Flange DN 5 PN 0 Form B, EN 09-/ C 0 5 Alloy C (.60) plated Flange DN 5 PN 0 Form B, EN/36L/PFA ) C 0 6 Flange DN 5 PN 0 Form B, EN 09-/ Enamelled 3) C 0 7 Flange DN 5 PN 0 Form B, EN 09-/36L C 0 8 Flange DN 5 PN 0 Form F, EN 09-/36L C 0 Flange DN 5 PN 63 Form B, EN 09-/36L C Flange DN 5 PN 00 Form B, EN 09-/36L C Flange DN 0 PN 0 Form B, EN/36L C 3 Flange DN 0 PN 0 Form B, EN 09-/PFA ) C Flange DN 0 PN 0 Form B, EN/36L C 5 Siemens FI 0 Update /07 /79

10 , Rigid extension in liquid applications such as overflow, high, 7ML low, and demand applications, as well as pump protection. For use in SIL- and hazardous applications. Flange DN 50 PN 0 Form B, EN/36L C 6 Flange DN 50 PN 0 Form B, EN 09-/ C 7 Alloy C (.60) plated Flange DN 50 PN 0 Form B,EN 09-/ C 8 Alloy 00 (.360) ZB977 Flange DN 50 PN 0 Form B, EN 09-/ECTFE ) C 0 Flange DN 50 PN 0 Form B, EN/36L/PFA ) C Flange DN 50 PN 0 Form B, EN 09-/ Enamelled 3) C Flange DN 50 PN 0 Form C, EN 09-/36L C 3 Flange DN 50 PN 0 Form D, EN/36L C Flange DN 50 PN 0 Form D, EN 09-/ C 5 Alloy C (.60) plated Flange DN 50 PN 0 Form B, EN 09-/36L C 6 Flange DN 50 PN 0 Form E, EN 09-/36L C 7 Flange DN 80 PN 0 Form B, EN 09-/36L C 8 Flange DN 80 PN 0 Form B, EN 09-/ C 3 0 Alloy C (.60) plated Flange DN 80 PN 0 Form B, EN 09-/ECTFE ) C 3 Flange DN 80 PN 0 Form B, EN 09-/ Enamelled 3) C 3 Flange DN 80 PN 0 Form B, EN 09-/36L C 3 3 Flange DN 00 PN 6 Form B, EN 09-/36L C 3 Flange DN 00 PN 6 Form B, EN 09-/ C 3 5 Alloy C (.60) plated Flange DN 00 PN 6 Form B, EN 09-/ Enamelled 3) C 3 6 Flange DN 00 PN 0 Form B, EN 09-/36L C 3 7 Flange DN 00 PN 0 Form B, EN 09-/ Enamelled 3) C 3 8 Flange DN 00 PN 0 Form C, EN 09-/36L C 0 Flange DN 00 PN 63 Form B, EN 09-/36L C Flange DN 50 PN 6 Form B, EN 09-/36L C Flange DN 50 PN 6 Form B, EN 09-/PFA ) C 3 Flange DN 50 PN 0 Form B, EN 09-/36L C Flange DN 50 PN 0 Form B, EN 09-/ECT- FE ) C 5 Flange DN 50 PN 0 Form B, EN 09-/36L C 6 Flange " 50 lb ASME B6.5/36L C 7 Flange "50 lb RF, ASME B6.5/Alloy C (.60) C 8 plated Flange "50 lb RF, ASME B6.5//Alloy 00 C 5 0 (.360) ZB977 Flange " 50 lb RF, ASME B6.5/ECTFE ) C 5 Flange "50 lb RF, ASME B6.5/PFA ) C 5 Flange " 50 lb RF, ASME B6.5/Enamelled 3) C 5 3 Flange " 300 lb RF, ASME B6.5/36L C 5 Flange " 300 lb RF, ASME B6.5/ECTFE ) C 5 5 Flange " 600 lb RF, ASME B6.5/36L C 5 6 Flange ½" 50 lb RF, ASME B6.5/36L C 5 7 Flange ½" 50 lb RF, ASME B6.5/ C 5 8 Alloy C (.60) plated Flange ½" 50 lb RF, ASME B6.5/ECTFE ) C 6 0 Flange ½" 50 lb RF, ASME B6.5/PFA ) C 6 Flange ½" 50 lb RF, ASME B6.5 Enamelled 3) C 6 Flange ½" 50 lb FF, ASME B6.5/ECTFE ) C 6 3 Flange ½" 300 lb RF, ASME B6.5/36L C 6 Flange ½" 300 lb RF, ASME B6.5/ C 6 5 Alloy 00 (.360) ZB977 Flange ½" 300 lb RF, ASME B6.5/ECTFE ) C 6 6, Rigid extension in liquid applications such as overflow, high, 7ML low, and demand applications, as well as pump protection. For use in SIL- and hazardous applications. Flange ½" 600 lb RF, ASME B6.5/36L C 6 7 Flange " 50 lb RF, ASME B6.5/36L C 6 8 Flange " 50 lb RF, ASME B6.5/Alloy C C 7 0 (.60) plated Flange " 50 lb RF, ASME B6.5/ C 7 Alloy 00 (.360) ZB977 Flange " 50 lb RF, ASME B6.5/ECTFE ) C 7 Flange " 50 lb RF, ASME B6.5/PFA ) C 7 3 Flange " 50 lb RF, ASME B6.5/Enamelled 3) C 7 Flange " 50 lb FF, ASME B6.5/36L C 7 5 Flange " 50 lb FF, ASME B6.5/ECTFE ) C 7 6 Flange " 50 lb SG (small groove), C 7 7 ASME B6.5/36L Flange " 300 lb RF, ASME B6.5/36L C 7 8 Flange " 300 lb RF, ASME B6.5/Alloy C C 8 0 (.60) plated Flange " 300 lb RF, ASME B6.5/ECTFE ) C 8 Flange " 300 lb RF, ASME B6.5/PFA ) C 8 3 Flange " 300 lb RJF, ASME B6.5/36L C 8 5 Flange " 300 lb ST, ASME B6.5/36L C 8 6 Flange " 300 lb LG (large groove), C 8 7 ASME B6.5/36L Flange " 300 lb LT, ASME B6.5/36L C 8 8 Flange " 600 lb RF, ASME B6.5/36L D 0 0 Flange " 600 lb RF, ASME B6.5/Alloy 00 D 0 (.360) ZB977 Flange " 600 lb RF, ASME B6.5/ECTFE ) D 0 Flange " 600 lb RJF, ASME B6.5/36L D 0 3 Flange " 600 lb LG, ASME B6.5/36L D 0 Flange " 900 lb RJF, ASME B6.5/36L D 0 5 Flange ½" 50 lb RF, ASME B6.5/36L D 0 6 Flange ½" 300 lb RF, ASME B6.5/36L D 0 7 Flange 3" 50 lb RF, ASME B6.5/36L D 0 8 Flange 3" 50 lb RF, ASME B6.5/Alloy C D 0 (.60) plated Flange 3" 50 lb RF, ASME B6.5/Alloy 00 D (.360) ZB977 Flange 3" 50 lb RF, ASME B6.5/ECTFE ) D Flange 3" 50 lb RF, ASME B6.5/PFA ) D 3 Flange 3" 50 lb RF, ASME B6.5/Enamelled 3) D Flange 3" 50 lb FF, ASME B6.5/36L D 5 Flange 3" 50 lb FF, ASME B6.5/ECTFE ) D 6 Flange 3" 50 lb FF, ASME B6.5/PFA ) D 7 Flange 3" 300 lb RF, ASME B6.5/36L D 8 Flange 3" 300 lb RF, ASME B6.5/Alloy C D 0 (.60) plated Flange 3" 300 lb RF, ASME B6.5/ECTFE ) D Flange 3" 300 lb RF, ASME B6.5/PFA ) D Flange 3" 300 lb RF, ASME B6.5/Enamelled 3) D 3 Flange 3" 600 lb RF, ASME B6.5/36L D Flange 3½" 50 lb RF, ASME B6.5/36L D 5 Flange 3½" 50 lb RF, ASME B6.5/ECTFE ) D 6 Flange " 50 lb RF, ASME B6.5/36L D 7 Flange " 50 lb RF, ASME B6.5/Alloy C D 8 (.60) plated Flange " 50 lb RF, ASME B6.5/ECTFE ) D 3 0 Flange " 50 lb RF, ASME B6.5/PFA ) D 3 Flange " 50 lb RF, ASME B6.5/Enamelled 3) D 3 Flange " 50 lb LT, ASME B6.5/36L D 3 3 /80 Siemens FI 0 Update /07

11 , Rigid extension in liquid applications such as overflow, high, low, and demand applications, as well as pump protection. For use in SIL- and hazardous applications. 7ML Flange " 300 lb RF, ASME B6.5/36L D 3 Flange " 300 lb RF, ASME B6.5/Alloy C D 3 5 (.60) plated Flange " 300 lb RF, ASME B6.5/ECTFE ) D 3 6 Flange " 300 lb RJF, ASME B6.5/36L D 3 7 Flange " 300 lb LG, ASME B6.5/36L D 3 8 Flange " 300 lb LT, ASME B6.5/36L D 0 Flange " 600 lb RF, ASME B6.5/36L D Flange " 600 lb RJF, ASME B6.5/36L D Flange 5" 50 lb RF, ASME B6.5/36L D 3 Flange 6" 50 lb RF, ASME B6.5/36L D Flange 6" 50 lb RF, ASME B6.5/Alloy C D 5 (.60) plated Flange 6" 50 lb RF, ASME B6.5/ECTFE ) D 6 Flange 6" 50 lb RF, ASME B6.5/PFA ) D 7 Flange 6" 50 lb RJF, ASME B6.5/36L D 8 Flange 6" 300 lb RF, ASME B6.5/36L D 5 0 Flange 8" 50 lb RF, ASME B6.5/36L D 5 Flange 8" 50 lb RF, ASME B6.5/ECTFE ) D 5 Flange " BS.0 Table E/36L D 5 3 Flange " BS.0 Table E/PFA ) D 5 Flange ½" BS.0 Table E/36L D 5 5 Flange 3½" BS.0 Table E/36L D 5 6 Flange " BS.0 Table E/ECTFE ) D 5 7 Flange DN 0 0K, JIS/36L D 5 8 Flange DN 50 0K, JIS/36L D 6 0 Flange DN 80 0K, JIS/36L D 6 Flange DN 00 0K, JIS/36L D 6 Thread R PN6, EN06-/36L ) D 6 5 Flange " 900 lb RF, ASME B6.5/36L D 7 0 Flange " 50 lb RF, ASME B6.5/Alloy C D 7 (.60) solid Adapter/Process temperature Without adapter/ C With adapter/ C 3) With adapter/ C 0) 3 With gas-tight leadthrough/ C With gas-tight leadthrough/ C 0) 5 Housing/Cable entry Aluminum IP66/IP67/M0 x.5 A Aluminum IP66/IP67/½" NPT B 36L stainless steel (electropolished) C IP66/IP67/M0 x.5 36L stainless steel (electropolished) D IP66/IP67/½" NPT Plastic single chamber IP66/IP67/M0 x.5 E Plastic single chamber IP66/IP67/½" NPT F Stainless steel chamber (precision casting) IP66/IP67/M0 x.5 G Stainless steel chamber (precision casting) H IP66/IP67/½" NPT Aluminum IP66/IP67/M0 x.5 Special HARTING V plug (bent) according to Tier One (ZB7555) NOTE: When selecting a Rigid Extension option, extension coating must match the process connection coating and the material and surface roughness type. Rigid Extension 36L mm A mm A mm A, Rigid extension in liquid applications such as overflow, high, 7ML low, and demand applications, as well as pump protection. For use in SIL- and hazardous applications mm A mm A mm A mm A mm A 7 Rigid Extension ECTFE coated mm B mm B mm B mm B mm B mm B 5 Rigid Extension PFA coated mm C mm C mm C mm C mm C mm C mm C mm C 7 Rigid Extension 36L Ra 0.8 μm mm D mm D mm D mm D mm D mm D mm D mm D 7 Rigid Extension 36L Ra 0.3 μm mm E mm E mm E mm E mm E mm E mm E mm E 7 Rigid Extension Enamelled version mm F mm F mm F mm F mm F mm F 5 Rigid Extension Alloy C (.60) mm G mm G mm G mm G mm G mm G mm G mm G 7 Siemens FI 0 Update /07 /8

12 , Rigid extension 7ML577- in liquid applications such as overflow, high, low, and demand applications, as well as pump protection. For use in SIL- and hazardous applications. Rigid Extension Alloy 00 (.360) mm H mm H mm H mm H mm H mm H 5 Order code Further designs Please add "-Z" to and specify Order code(s). Switching status indication with colors red-green ) A Cleaning including Certificate W0 (oil, grease, and silicone free) Enter the total insertion length in plain text Y0 description, max. 000 mm (57.8 inch) Identification label (measurement loop) stainless Y7 steel: max. 0 characters, add in plain text. To add more than one line, use a coma "," for line break. Identification Label (measurement loop) foil: Y8 max. 0 characters add in plain text. To add more than one line, use a coma "," for line break. NACE075 to 3. Material Certificate for material D07 (EN00 NACE MR 075) 8) Note: not available with Process connection and Rigid extension coatings PFA, ECTFE, and Enamel. NACE not available with Hygienic process connections..-factory certificate for material (EN 00) 8) C5 Functional Safety (SIL ). Device suitable for use in C0 accordance with IEC 6508 and IEC 65 8) Dye penetration test, results confirmed via a C3 3. certificate/instrument (EN 00) 8) X-ray test + 3. certificate/instrument 8) C Positive material identification test C certificate/instrument 8) Roughness test + 3. certificate/instrument 8) C8 3.-Inspection Certificate for instrument with test C5 data (EN 00) Quality and test plan C6 Pressure test + 3. certificate/instrument 8) C3 Helium leak test + 3. certificate/instrument 8) C3 Ferrite measuring accuracy to DIN 35- C certificate/instrument 8) Pressure test according to Norsok C certificate/instrument 8) Operating Instructions All literature is available to download for free, in a range of languages, at processinstrumentation/documentation Spare Parts and Accessories Electronics module Relay Electronics module Contactless NAMUR spare electronics module Lock fitting, unpressurized, G" A/36L Lock fitting, unpressurized, " NPT/36L Lock fitting, unpressurized, G.../" A/36L Lock fitting, unpressurized,... /" NPT/36L Lock fitting, bar, G" A/36L Lock fitting, bar, " NPT/36L Lock fitting, bar, G... /" A/36L Lock fitting, bar,... /" NPT/36L Lock fitting, bar, G" A/36L Lock fitting, bar, " NPT/36L Lock fitting, bar, G... /" A/36L Lock fitting, bar,... /" NPT/36L 7ML830-NC 7ML930-6AA A5E ML930-DQ 7ML930-DR 7ML930-DS 7ML930-DT 7ML930-DU 7ML930-DV 7ML930-DW 7ML930-DX 7ML930-EA 7ML930-EB 7ML930-EC 7ML930-ED ) Available only with Adapter/Process temperature options, 3,, and 5. ) Available only with Housing/Cable entry option B. 3) Available only with Adapter/Process temperature options,, and. ) Not available with Adapter/Process temperature options, 3, and 5. 5) Not available with Adapter/Process temperature options,, and 5. 6) Available only with Electronics options and 6. 7) Available only with rigid extension options less than 3 00 mm. 8) Listed Certificates are not available with all configurations please contact factory for more information. 9) Not available with Housing/Protection/Cable option V. 0) Not available with PFA, ECTFE, and enamelled coating options. ) Available only with some 36L extensions. ) Available only with relay electronic options and non-hazardous Approval options. 3) Available only with Enamelled Process connection/material options. ) Not available with Approval options C, E, G, H, L, N, V, and W. 5) Not available with Approval options C, E, G, H, N, and V. 6) Only available with Aluminum Housing/Protection/Cable options and certain glands. 7) Not available with Stainless Steel Electropolish Housing/Protection/Cable options and certain glands. 8) Not available with Plastic or Stainless Steel Electropolish Housing/Protection/Cable options and certain glands. 9) Not available with Housing/Protection/Cable options D and V. 0) Not available with Housing/Protection/Cable options A, E, G, and V. ) Not available with some Housing/Protection/Cable gland options. ) Not available with Housing/Protection/Cable options A, C, and V. /8 Siemens FI 0 Update /07

13 SITRANS SCSC, single channel, signal conditioner for Single channel signal conditioning instrument for level detection with relay output for one LVL vibrating switch with electronics version two-wire 8/6 ma. Provides remote test of LVL00. Click on the for the online configuration in the PIA Life Cycle Portal. Approvals For Ex-free area ATEX II () G/D [Ex ia Ga/Da] IIC/IIIC, I (M) [Ex ia Ma] I IEC [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I SIL qualification 7ML A A D Without Version Single-channel (8/6 ma) for level detection Single channel (8/6 ma), level detection with fail safe relay Housing/cable entry Plastic/IP0 A Terminal block connection Detachable.5 mm²/ Ex sensor: x blue; output A and operating voltage: x black Detachable.5 mm²/ sensor: x black; output B and operating voltage: x black Language English 0 German Operating Instructions All literature is available to download for free, in a range of languages, at processinstrumentation/documentation H Order code SITRANS TCSC, two channel, signal 7ML576- conditioner for 7 7 A Two channel signal conditioning instrument for level detection with relay output for two LVL vibrating switches with electronics version two-wire 8/6 ma. Provides remote test of LVL00. Click on the for the online configuration in the PIA Life Cycle Portal. Approvals For Ex-free area ) A ATEX II () G/D [Ex ia Ga/Da] IIC/IIIC, I (M) D [Ex ia Ma] I ) IEC [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I ) H SIL qualification Without Version Double-channel (8/6 ma) for level detection Housing/cable entry Plastic/IP0 A Terminal block connection Detachable.5 mm²/ Ex sensor: x blue; A output and operating voltage: x black Detachable.5 mm²/ sensor: x black; B output and operating voltage: x black Language English 0 German Operating Instructions All literature is available to download for free, in a range of languages, at processinstrumentation/documentation ) Available only with terminal block connection option B ) Available only with terminal block connection option A Order code Siemens FI 0 Update /07 /83

Point level measurement Vibrating switches

Point level measurement Vibrating switches Level Measurement Overview Configuration Horizontal mounting switching point (recommended mounting position, particularly for adhesive applications) marked with screwed version on top, with flange versions

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens A 207 Overview Application The SITRANS P Compact pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials

More information

Differential pressure

Differential pressure Differential pressure 9 Overview Page 200 VEGADIF 65 Page 202 Chemical seal Page 204 Accessory Page 208 199 VEGADIF For differential pressure, level and flow measurements Measuring principle The sensor

More information

Level switches Series LD Vibrating fork level switch for liquids and solids

Level switches Series LD Vibrating fork level switch for liquids and solids Level switches Series LD Vibrating fork level switch for liquids and solids Robust and compact Suitable for liquids (model LD61) and solids (model LD60) No moving parts, low maintenance Corrosion resistant

More information

Level switches Series LD Vibrating fork level switch for liquids and solids

Level switches Series LD Vibrating fork level switch for liquids and solids Level switches Series LD Vibrating fork level switch for liquids and solids Robust and compact Suitable for liquids (model LD61) and solids (model LD60) No moving parts, low maintenance Corrosion resistant

More information

Level measurement. Continuous level measurement Guided wave radar transmitters. SITRANS LG series. 4/208 Siemens FI

Level measurement. Continuous level measurement Guided wave radar transmitters. SITRANS LG series. 4/208 Siemens FI Siemens AG 201 Overview The Siemens are guided wave radar transmitters for level, level/interface, and volume measurement of liquids and solids. The Sitrans LG product line can handle changes in process

More information

Ultrasonic. 58 Overview VEGASON 60 VEGASON 61, 62, 63

Ultrasonic. 58 Overview VEGASON 60 VEGASON 61, 62, 63 Ultrasonic 58 Overview VEGASON 60 VEGASON 61, 62, 63 57 Overview VEGASON Area of application The ultrasonic sensors of the VEGASON series are suitable for non-contact level measurement of liquids and bulk

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and

More information

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure Z series for gage pressure Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection

More information

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765 Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765 Application Single-acting positioner for attachment to pneumatic control valves. Supplied with either an electric input signal from

More information

Level detection in bulk solids. Vibration VEGAVIB VEGAWAVE Product Information

Level detection in bulk solids. Vibration VEGAVIB VEGAWAVE Product Information Level detection in bulk solids Vibration VEGAVIB 61-63 VEGAWAVE 61-63 Product Information Contents Contents 1 Description of the measuring principle...........................................................

More information

TDR Guided Wave Radar

TDR Guided Wave Radar TDR Guided Wave Radar Continuous level measurement evel Overview Page 48 VEGAFEX series 80 Page 50 47 VEGAFEX Universal sensors for liquids and bulk solids Measuring principle High frequency microwave

More information

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure Siemens AG 204 Overview The pressure transmitter SITRANS P220 measures the gauge pressure of liquids, gases and vapors. Stainless steel measuring cell, fully welded Measuring ranges 2.5 to 600 bar (36.3

More information

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.

More information

Hydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN

Hydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN Hydrostatic Continuous level measurement 8 Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 187 Hydrostatic Level and pressure measurement Measuring principle The pressure

More information

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition Siemens AG 07 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure

More information

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI Siemens AG 06 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure

More information

Limit level measurement of bulk solids Vibration VEGAVIB VEGAWAVE Product Information

Limit level measurement of bulk solids Vibration VEGAVIB VEGAWAVE Product Information Limit level measurement of bulk solids Vibration VEGAVIB 61-63 VEGAWAVE 61-63 Product Information Content Content 1 Description of the measuring principle..................................................

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens AG 07 Overview Function U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/ Equipotential bonding Diaphragm The pressure

More information

Ultrasonic. Continuous level measurement. Overview Page 64 VEGASON series 60 Page 66 AL-EN

Ultrasonic. Continuous level measurement. Overview Page 64 VEGASON series 60 Page 66 AL-EN Ultrasonic Continuous level measurement Overview Page 64 VEGASON series 60 Page 66 6 VEGASON Non-contact measurement with ultrasonics Measuring principle Short ultrasonic pulses in the range of 5 to 70

More information

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. Supplied with an electric input signal of 4 to 20

More information

Flow Measurement SITRANS F C

Flow Measurement SITRANS F C Overview High-pressure program as standard The sensor calibration factor is also valid for gas measurement. SITRANS FC00 is a compact Coriolis mass sensor suitable for flow measurement of a variety of

More information

Flow Measurement SITRANS F X

Flow Measurement SITRANS F X Overview Using a vortex flowmeter with integrated pressure and temperature compensation such as the allows you not only to lower installation costs but also increase the measuring accuracy of the measuring

More information

Product information. Capacitive. Level detection in liquid VEGACAP 62 VEGACAP 63 VEGACAP 64 VEGACAP 66 VEGACAP 69. Document ID: 29983

Product information. Capacitive. Level detection in liquid VEGACAP 62 VEGACAP 63 VEGACAP 64 VEGACAP 66 VEGACAP 69. Document ID: 29983 Product information Level detection in liquid VEGACAP 62 VEGACAP 63 VEGACAP 64 VEGACAP 66 VEGACAP 69 Document ID: 29983 Contents Contents 1 Description of the measuring principle... 3 2 Type overview...

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.

More information

Product information Vibrating

Product information Vibrating Product information Level detection in bulk solids VEGAVIB 61 VEGAVIB 62 VEGAVIB 63 VEGAWAVE 61 VEGAWAVE 62 VEGAWAVE 63 Document ID: 29438 Contents Contents 1 Description of the measuring principle...

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 00 Model Number Features 5 mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,

More information

Technical Data. Dimensions

Technical Data. Dimensions 00 Model Number Features mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,

More information

Pressure Switches Application Guideline

Pressure Switches Application Guideline Pressure Switches Application Guideline Product Overview The Fema Pressure Switch product portfolio provides devices suitable for many applications. The portfolio contains Special functions and equipment

More information

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC Mechatronic pressure measurement Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC WIKA data sheet PV 35.41 Process Compact Series Applications Differential pressure monitoring

More information

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor Precision- Pressure Transmitter for Food ndustry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to EC 60770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 40 bar Output

More information

VEGAVIB VEGAWAVE 61-63

VEGAVIB VEGAWAVE 61-63 Level detection of bulk solids Vibration VEGAVIB 61-63 VEGAWAVE 61-63 Product Information Contents Contents 1 Description of the measuring principle.... 3 2 Type overview.... 5 3 Mounting instructions...

More information

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

Type N-10, N-11 Hazardous Area Non-incendive Transmitters Electronic Pressure Catalog > Hazardous Area > N-10, N-11 Type N-10, N-11 Hazardous Area Non-incendive Transmitters Applications Natural gas compressors Wellhead monitoring Pipeline pressure General industrial

More information

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0. Precision Pressure Transmitter for Food ndustry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to EC 60770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 40 bar Output

More information

Monitoring device NTS 30

Monitoring device NTS 30 P R O D U C T I N F O R M A T I O N Electronic level- and temperature monitoring device Monitoring device NTS 30 Contents Description Description... 2 Operating... 3 Design and electrical data... 4 Circuit

More information

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview f gauge pressure Siemens AG 010 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure Siemens AG 007 SITRANS P measuring instruments for pressure / Product overview /4 Transmitters for gage and absolute pressure /4 Z series for gage and absolute pressure /9 ZD series for gage and absolute

More information

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0. LMP 07 Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % / 0. % FSO Nominal pressure from 0... mho up to 0... 50 mho Output signals -wire: 4... 0 ma -wire: 0...

More information

Level transmitter LT 100

Level transmitter LT 100 KROHNE 09/2001 7.02363.21.00 GR/PRINTO Level transmitter LT 100 Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters

More information

GA24 Technical Datasheet

GA24 Technical Datasheet GA24 Technical Datasheet Variable-area flowmeter Sturdy construction for several applications Local indication without auxiliary power Replaceable mounting parts KROHNE CONTENTS GA24 1 Product features

More information

Pressure Transmitter P41

Pressure Transmitter P41 SENSORS FOR AND BIOPHARMA. Product Information P41 Pressure Transmitter P41 Application/Specified usage Pressure measurement in pipes and tanks For process temperatures up to 250 C (428 F) with optional

More information

Siemens AG psi (6 bar) 145 psi (10 bar) 464 psi (32 bar) 1450 psi (100 bar) 3626 psi (250 bar) 8700 psi (600 bar) psi (800 bar)

Siemens AG psi (6 bar) 145 psi (10 bar) 464 psi (32 bar) 1450 psi (100 bar) 3626 psi (250 bar) 8700 psi (600 bar) psi (800 bar) Technical specifications SITRANS P, DS III series Input Measured variable Spans (infinitely adjustable) or nominal measuring range and max. permissible test pressure HART Gauge pressure Span (min.... max.)

More information

Flow Measurement SITRANS F X

Flow Measurement SITRANS F X SITRANS FX00 Overview The main applications of SITRANS FX00 can be found in the following sectors: Chemical Petrochemical Oil & Gas Power plants -Air - Heating - Cooling -Chilling Food & beverage - Pharmaceutical

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications

More information

2600T Series Pressure Transmitter

2600T Series Pressure Transmitter Data Sheet 2600T Series Pressure Transmitter Model 261GC/GG/GJ/GM/GN Gauge Model 261AC/AG/AJ/AM/AN Absolute with direct mount seal Base accuracy: ±0.15 % Span limits 0.3 to 60000kPa; 1.2inH 2 O to 8700psi

More information

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement Model LH-20 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater

More information

1 Overview. Pressure Measurement Remote seals for transmitters and pressure gauges SITRANS P320/P420. 1/352 Siemens FI US Edition

1 Overview. Pressure Measurement Remote seals for transmitters and pressure gauges SITRANS P320/P420. 1/352 Siemens FI US Edition Siemens AG 08 Technical description Overview In many cases the pressure transmitter and the measured medium have to be physically separated. It is then necessary to use a remote seal. The remote seals

More information

Climatic Independent Level Sensor LAR

Climatic Independent Level Sensor LAR 1 Product Information LAR-361 LAR-761 Climatic Independent Level Sensor LAR Application / Specified usage Authorizations Hydrostatic level measurement in humid ambiance Special applicable for exterior

More information

VA40 - VA45 Technical Datasheet

VA40 - VA45 Technical Datasheet VA40 - VA45 Technical Datasheet Variable area flowmeter Local indication without auxiliary power Adaptable to meet customers' requirements Replaceable mounting parts KROHNE CONTENTS VA40 - VA45 1 Product

More information

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement Model LH-20 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater

More information

Liquid level instruments BM 24 /BM 51

Liquid level instruments BM 24 /BM 51 KROHNE 09/2001 7.02362.21.00 GR/PRINTO Liquid level instruments / Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters

More information

3000 Series OPTIMASS Mass Flowmeter. Stainless Steel Hastelloy

3000 Series OPTIMASS Mass Flowmeter. Stainless Steel Hastelloy KROHNE 07/2005 7.02446.25.00 GR 3000 Series OPTIMASS Mass Flowmeter with single Z-shaped measuring tube Stainless Steel Hastelloy Status: 10/99 One tube no limits No limits with tube material No limits

More information

Flow Measurement SITRANS F C

Flow Measurement SITRANS F C Overview The flow measuring principle is based on the Coriolis Effect. The FCS400 sensor s measuring tubes are energized by an electromechanical driver circuit which oscillates them at their resonance

More information

Rosemount 2130 Extreme Temperature Vibrating Fork Liquid Level Switch

Rosemount 2130 Extreme Temperature Vibrating Fork Liquid Level Switch Technical Note ommunicate Rosemount 2130 Rosemount 2130 Extreme Temperature Vibrating Fork Liquid Level Switch The Rosemount 2130 Vibrating Fork Level Switch, based on vibrating short fork technology,

More information

ED 701 Hygenic Pressure Transmitter

ED 701 Hygenic Pressure Transmitter ED 701 Hygenic Pressure Transmitter Hygienic process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response time < 25 ms (Option

More information

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm 0102 Model Number Features 2 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-12 Quick mounting bracket with dead stop BF 12 Mounting flange, 12 mm Technical Data specifications Switching

More information

Liquiphant FailSafe FTL80, FTL81, FTL85

Liquiphant FailSafe FTL80, FTL81, FTL85 Technical Information Liquiphant FailSafe FTL80, FTL8, FTL85 Vibronic Point level switch for liquids Application The Liquiphant FailSafe is a point level switch for minimum and maximum detection (MIN/MAX)

More information

High-performance submersible pressure transmitter For level measurement Model LH-10

High-performance submersible pressure transmitter For level measurement Model LH-10 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well

More information

C-Flow Coriolis Mass Flow Meters

C-Flow Coriolis Mass Flow Meters Coriolis Mass Flow Meters Ready for Take Off The New Compact C-Flow Küppers Elektromechanik GmbH The C-Flow The C-Flow Coriolis Mass Meters consist of two components: KCE Transmitter KCM Transducer 2 KEM

More information

Radiation-based Overview Page 214 FIBERTRAC Page 216 SOLITRAC Page 218 MINITRAC Page 220 POINTRAC Page 222 WEIGHTRAC Page 224

Radiation-based Overview Page 214 FIBERTRAC Page 216 SOLITRAC Page 218 MINITRAC Page 220 POINTRAC Page 222 WEIGHTRAC Page 224 Detectors Radiation-based Overview Page 214 FIBERTRAC Page 216 SOLITRAC Page 218 MINITRAC Page 220 POINTRAC Page 222 WEIGHTRAC Page 224 213 FIBERTRAC, SOLITRAC, MINITRAC, POINTRAC, WEIGHTRAC Radiation-based

More information

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. An electric standardized signal of 4 to 20 ma or

More information

ATM.1ST/Ex - High Precision Transmitter

ATM.1ST/Ex - High Precision Transmitter Pressure Transmitter - ATEX / IECEx certified ATM.1ST/Ex - High Precision Transmitter CUSTOMER BENEFITS Certificate: ATEX, IECEx & EAC High measurement accuracy is ensured by sophisticated digital temperature

More information

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications. Rated operating distance s n 5 mm 0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching

More information

Torque Tube TB300 Digital Transmitters

Torque Tube TB300 Digital Transmitters Page 1 of 7 7E.300-E Issue 4-2009 Description Series TB300 torque tube liquid level instruments utilize the buoyancy exerted on a displacer when immersed in a liquid. The buoyancy on the displacer is proportional

More information

Siemens AG Span (min... max.) Max. perm. test. 87 psi (6 bar) 145 psi (10 bar) 464 psi (32 bar) 1450 psi (100 bar)

Siemens AG Span (min... max.) Max. perm. test. 87 psi (6 bar) 145 psi (10 bar) 464 psi (32 bar) 1450 psi (100 bar) SITRANS P S III for gauge/absolute pressure, Technical specifications SITRANS P S III series for gauge and absolute pressure, HART PROFIBUS PA and FOUNATION Fieldbus Input of gauge pressure, Measured variable

More information

Product information. Capacitive. Level detection with bulk solids VEGACAP 62 VEGACAP 65 VEGACAP 66 VEGACAP 67. Document ID: 29982

Product information. Capacitive. Level detection with bulk solids VEGACAP 62 VEGACAP 65 VEGACAP 66 VEGACAP 67. Document ID: 29982 Product information Level detection with bulk solids VEGACAP 62 VEGACAP 65 VEGACAP 66 VEGACAP 67 Document ID: 29982 Contents Contents 1 Description of the measuring principle... 3 2 Type overview... 5

More information

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0. Pressure Transmitter for Marine and Offshore Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0. % FSO Nominal pressure from 0... 40 mbar up to 0... 0 bar Output signals -wire:

More information

Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85

Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85 XA01537F-A/00/EN/01.16 71333275 Products Solutions Services Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85 0Ex ia IIC T6 Ga X Ga/Gb Ex ia IIC T6 X Document: XA01537F-A Safety instructions

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure Remote seals for transmitters and pressure gauges Technical description Overview In many cases the pressure transmitter and the measured medium have to be physically separated. It is then necessary to

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 2 mm flush Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 2 mm Installation flush Output

More information

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable

More information

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries Series 2000 ALL STAINLESS DESIGN EASY CALIBRATION WITHOUT TEST PRESSURE BY 3 PUSH BUTTONS ACCURACY 0,1% 4-20 ma AND HART PROTOCOL ATEX II

More information

sitrans p Operating Instructions (de/en) Edition 03/2004

sitrans p Operating Instructions (de/en) Edition 03/2004 (de/en) Edition 03/2004 sitrans p Messumformer für Food, Pharma und Biotechnik Transmitters for food, pharmaceuticals and biotechnologgy 7FM8010 Contents Information for the operator...27 Important security

More information

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm 0102 Model Number Features 1.5 mm flush Accessories BF 8 Mounting flange, 8 mm Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 1.5 mm Installation flush

More information

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement Model LH-20 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater

More information

How to specify a product. Process Sensors and Mechanical Instruments

How to specify a product. Process Sensors and Mechanical Instruments How to specify a product Process Sensors and Mechanical Instruments Keep the overview. Here is some guideline information on how to specify our products. Intended as supplementary help to specification

More information

Technical Data. Dimensions

Technical Data. Dimensions 00 Model Number Features Comfort series 30 mm non-flush Accessories MHW 0 Modular mounting bracket V-G Female connector, M, 4-pin, field attachable V-W-N-M-PUR Female cordset, M, -pin, NAMUR, PUR cable

More information

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications Technical Datasheet D Series SMART Pressure Transmitter Model: DPC-2000 Key Features ATEX - Flameproof and Intrinsically Safe IECEx - Flameproof and Intrinsically Safe SIL 2 certificate Compliant to NAMUR

More information

Mobrey 9700 Transmitter Submersible Hydrostatic Level Transmitters

Mobrey 9700 Transmitter Submersible Hydrostatic Level Transmitters Product Data Sheet Mobrey 9700 Transmitter Mobrey 9700 Transmitter Submersible Hydrostatic Level Transmitters Hydrostatic electronic level transmitters Factory sealed and tested for submersed duty 4 20

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 15 mm non-flush Stainless steel housing Accessories BF 30 Mounting flange, 30 mm Technical Data specifications Switching element function NAMUR, NC Rated operating

More information

Flow Measurement SITRANS F C

Flow Measurement SITRANS F C Overview The flow measuring principle is based on the Coriolis Effect. The FCS400 sensor s measuring tubes are energized by an electromechanical driver circuit which oscillates them at their resonance

More information

ATM.ECO/IS - Analog Transmitter with Temperature compensation

ATM.ECO/IS - Analog Transmitter with Temperature compensation Pressure Transmitter - FM / FM-C certified ATM.ECO/IS - Analog Transmitter with Temperature compensation CUSTOMER BENEFITS Certificate: FM, FM-C & IECEx & ATEX Entry level series into precision pressure

More information

VG5 Supplementary instructions

VG5 Supplementary instructions VG5 Supplementary instructions 2-wire / 10 GHz Radar (FMCW) Level Meter Supplementary Instructions for ATEX applications HYCONTROL CONTENTS VG5 1 General safety information 4 1.1 Scope of the document...

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 6 mm flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,

More information

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries. VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet 34-VF-03-05 September 3rd, 2008 Specification The all-in-one solution The VERSAFLOW is the only vortex flowmeter with integrated pressure and

More information

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres Drawing 1 VA Di ZG1 Ex-d Measured variables actual flow rate

More information

Technical Data. General specifications. Rated operating distance s n 2 mm

Technical Data. General specifications. Rated operating distance s n 2 mm 0102 Model Number Features 2 mm flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Rated operating distance s n 2 mm Installation

More information

Pressure Measurement Transmitters for applications with advanced requirements (Advanced)

Pressure Measurement Transmitters for applications with advanced requirements (Advanced) Siemens AG 206 Technical specifications SITRANS P DS III series for absolute pressure (from the gauge pressure series) Input Measured variable Absolute pressure Span (fully adjustable) or measuring range,

More information

OPTIBAR P 1010 C Technical Datasheet

OPTIBAR P 1010 C Technical Datasheet Technical Datasheet Pressure transmitter with recessed diaphragm for general applications Wide variety thanks to modular design Measuring ranges up to 250 bar / 3750 psi High overload and temperature stability

More information

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.:

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.: Smart level probe type APC-2000ALW/L Programmable zero shift, range and damping ratio 4...20 ma output signal + HART protocol Accuracy 0,16% Local display Intrinsic safety certificate (ATEX, IECEx) II

More information

9700 Transmitter Submersible hydrostatic level transmitter

9700 Transmitter Submersible hydrostatic level transmitter Specification sheet IP0078 October 2007 Level 9700 Transmitter Submersible hydrostatic level transmitter Description The 9700 series hydrostatic level transmitter is designed to perform in the most arduous

More information

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm Dimensions M18x1 37 40 4 0102 24 LED Model Number Features 5 mm embeddable Usable up to SIL2 acc. to IEC 61508 Connection BN BU Accessories L+ L- EXG-18 Quick mounting bracket with dead stop BF 18 Mounting

More information

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm Dimensions M30x1,5 5 40 37 0102 Model Number 36 LED Features Comfort series 10 mm embeddable Connection BN BU Accessories BF 30 Mounting flange, 30 mm L+ L- Technical Data specifications Switching element

More information

Climatic Independent Level Sensor LAR

Climatic Independent Level Sensor LAR 3 JAHRE GEWÄHRLEISTUNG 1 Product Information LAR-361 LAR-761 f o o d Climatic Independent Level Sensor LAR 3 3 Y R S W A R R A N T Y Application / Specified usage Authorizations Hydrostatic level measurement

More information

A Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >

A Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit > A Higher Level of Performance Data Sheet Pressure and Level Transmitters For more information, please visit > www.hawkmeasure.com Description Intelligent pressure and level transmitters for all industries

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 10 mm flush Shielded PUR cable for oil and gas sector Accessories BF 30 Mounting flange, 30 mm Technical Data specifications Switching function Normally closed (NC) Output type

More information

LTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc.

LTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc. LTB013EN Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc. to IECEx scheme Subject to technical modification Bachofen AG Ackerstrasse 42

More information

4/2 way Pneumatic Solenoid Valve

4/2 way Pneumatic Solenoid Valve 4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11

More information

PEM-EX-C. Figure: PEM-EX-C*A*G. ka054000en; Rev. 2.7 J

PEM-EX-C. Figure: PEM-EX-C*A*G. ka054000en; Rev. 2.7 J PEM-EX-C J2013329 Figure: PEM-EX-C*A*G Robust and safe pressure transducer for general mining applications In combination with a Kirchgaesser multi channel signal converter and display unit COMBA-EX or

More information