Emergency Stop Devices/Rope Pull Switches

Size: px
Start display at page:

Download "Emergency Stop Devices/Rope Pull Switches"

Transcription

1 Rope pull switch with pulltoreset button for emergency stop device Metal housing Emergency stop device with detent mechanism according to EN ISO and EN Clamping head for pull rope Indication of correct rope tension 3 cable entries M20 x 1.5 Switching elements with 4 contacts for the rope tension optional An additional monitoring output is used to signal that the permissible rope tension is exceeded and to indicate imminent triggering. Switching elements f Slowaction switching contact Cable entry M20 x 1.5 Pulltoreset button for emergency stop, clamping head for tensioning rope Dimension drawing max.=282 / min.= ,5 8 Wiring diagrams Switch not activated ,5 78 5,4 M20x1,5 26 S=45 20,5 30,5 20,5 30,5 53 SW17 Clamping head 88 Emergency stop with pulltoreset button (red button) Window Cable glands, see page 20 S2 S For switching functions see technical data on Page 22 Series RPSM Cable entry 3 x M20 x 1.5 Rope attachment C Clamping head S Emergency stop Actuating force [N] Switching element Prefailure monitoring with without with without Order No./item RPSMESC175M RPSMSC175M RPSMESC300M RPSMSC300M 17

2 Accessories for rope pull switches Eyebolt Rope set Pulley set Turnbuckle Tensioning rope Eyebolt Thread M8 Dimension drawings Rope set 28, Thimble The builtin LED is suitable for direct installation in one of the M20 x 1.5 threads of the three cable entries in the rope pull switch RPS. The builtin LED indicates to the operator whether the switch is actuated or not. The switching element can be wired individually. Operating voltage DC 24 V +10%, 15% ~ Rope clamp Pulley set RPSPS/V5 Pulley set RPSP/V1 Turnbuckle Lefthanded thread 58 Ø 9 M Ø 14 M5 25 M6 RPSB660 = 60 RPSB6100 = Rope pulley block Pulley bracket 19 Rope pulley block 23,5 Pulley bracket Designation Packaging unit Order No./item Eyebolt Thread M8 5 ea. Rope set Consisting of thimble and rope clamp 5 ea. Pulley set RPSPS/V5 Pulley set RPSP/V1 Turnbuckle Consisting of rope pulley block and pulley bracket Consisting of rope pulley block and pulley bracket M6 x 60 M6 x ea. 5 ea RPSO850/V RPSRS/V RPSPS/V RPSP/V RPSB660/V RPSB

3 1 8 Emergency Stop Devices/Rope Pull Switches RPSW100/175: L0 min. = 383 RPSW300: L0 min. = min. Tensioning rope 28,7 38,5 26,5 R11,8 ca ,5 9,5 M20x1, RPSW100/175: L max. = 487 RPSW300: L max. = 653 F Plastic sheath, red SW27 Designation Packaging unit Order No./item Tensioning rope For tensile force 110 N / 175 N For tensile force 300 N Length 50 m Length 100 m Color red for cable entry M20 x 1.5, with seal Light radiation to side Color red for cable entry M20 x 1.5, with seal light radiation to front RPSW100/ RPSW RPSI34/50m RPSI34/100m LED M20x LEDF M20x1.5 19

4 Female connectors/extension cables for rope pull switch RPS...MR10 Female connector with cable 10pin Dimension drawings 64 Ø 9, Ø View on connection side, socket Female connector Cable length L Extension cable 10pin Ø 9, Ø Cable length L View on connection side, socket Female connector Coupling plug Assignment of female connector MR10 with cable Pin Wire color Conductor crosssection 1 OG 0.82 (18 AWG) 2 BU 0.82 (18 AWG) 3 WH/BK 0.82 (18 AWG) 4 RD/BK 0.82 (18 AWG) 5 GN/BK 0.82 (18 AWG) Pin Wire color Conductor crosssection 6 OG/BK 0.82 (18 AWG) 7 RD 0.82 (18 AWG) 8 GN/YE 0.82 (18 AWG) 9 BK 0.82 (18 AWG) 10 WH 0.82 (18 AWG) Material Cable length L 1,800 3,600 6,000 9,100 12,100 15,200 18,200 Female connector with cable Extension cable PVC PUR PVC PUR Cable glands M20 x 1.5 A B Cable glands Suitable for various cable diameters. s available in plastic and metal. Article Thread Cable A B E SW E M EKP.20/06 M20 x EKV.20/06 M20 x EKV.20/09 M20 x SW Thread Cable diameter 6 12 mm Metal Material Plastic EKPM20/06 M20 x 1.5 Cable diameter mm EKVM20/06 Cable diameter 9 13 mm EKVM20/09 20

5 Technical data, rope pull switch RPS The technical data on switches and switching elements apply to all connections. Further technical data are given for the connection selected. Reliability values acc. to EN ISO B10d RPS 2 x 10 4 operating cycles RPSM 2 x 10 5 operating cycles Switch, plastic housing Housing material Reinforced thermoplastic Actuation material Diecast zinc, steel Mechanical life Acc. to IEC Ambient temperature C Weight Approx kg Latching device Acc. to EN ISO RPS RPS RPS Actuating force N Rope length max m Rope diameter mm Rope attachment RPS...R... Via pull lug RPS...C... Via clamping head Reset Emergency Stop RPS...P... Blue reset button RPS...S... Emergency stop Switch, metal housing Housing material Diecast aluminum Actuation material Diecast zinc, steel Mechanical life Acc. to IEC Ambient temperature C Weight Approx kg Latching device Acc. to EN ISO RPS RPS Actuating force N Rope length max m Rope diameter mm Rope attachment RPS...C... Via clamping head Reset Emergency Stop RPS...S... Turntoreset button Switching element 4 Parameter Switching principle Switching element with 4 switching contacts NC + 1 NO Value Slowaction switching contact Contact opening gap > 2 x 2 mm Min. switching current at 24 V DC 10 ma Rated insulation voltage Ui 250 V AC/DC Conventional thermal current Ith 10 A Rated operating voltage U e 240 V Utilization category according to IEC AC15 Ie 3 A Ue 240 V / Ie 6 A Ue 120 V DC13 Ie 0.27 A Ue 250 V DC15 Ie 0.55 A Ue 125 V Short circuit protection acc. to IEC (control circuit fuse) 6 A DII/gG Safety class I Unit 21

6 , cable entry M20 x 1.5 M20x1,5 Parameter Screw terminal M20 x 1.5 Conductor crosssection mm² Degree of protection according to IEC IP 67 Rated insulation voltage Ui 250 V AC/DC Rated impulse withstand voltage Uimp 2.5 kv Conventional thermal current Ith 10 A Short circuit protection acc. to IEC (control circuit fuse) 6 A DII/gG Utilization category according to IEC AC15 Ie 3 A Ue 240 V Value Unit, plug connector MR10 10pol Parameter Plug connector MR10 (10pin) Degree of protection according to IEC IP 65 1) Rated insulation voltage Ui 50 V AC/DC Rated impulse withstand voltage Uimp 2.5 kv Conventional thermal current Ith 4 A Short circuit protection acc. to IEC (control circuit fuse) 4 A gg Utilization category according to IEC AC15 Ie 3 A Ue 50 V DC13 Ie 3 A Ue 24 V 1) Screwed tight with the related plug connector (see page 20) Value Unit Travel diagram RPS Travel diagram RPS... ON OFF Tensile force N ±15% 300N/175N/100N ON OFF Tensile force N ±15% 300N/175N/100N 240N/140N/80N 240N/140N/80N 180N/105N/60N 180N/105N/60N Travel diagram RPSM... with metal housing Travel diagram RPSME... with metal housing and prefailure monitoring ON OFF S1 S2 +6mm +4,8mm +4mm +3mm Tensile force N ±15% 300N / 175N 0mm 288N / 133N 3mm 4mm 4,8mm 6mm 156N / 91N 22

7 Technical data, rope pull switch RPS accessories Material of rope clamp Diecast zinc/steel Material of spring X12CrNi177 (1.4310) Eyebolt DIN 444 M12x504.6 Zn Ambient temperature C Rope diameter mm Rope attachment Quickaction clamping device RPSW100/175 RPSW300 Spring rate N/mm Maximum spring force N Weight Approx. 0.5 Approx kg Material of housing ABS/PC blend, black Material of cap Transparent polycarbonate Degree of protection (fitted in rope pull switch) IP 65 Ambient temperature C 2 strands Mounting M20 x 1.5 Operating voltage 24 V DC Switchon current < 0.5 A Current consumption 45 ma 23

Operating Instructions Rope Pull Switches RPS...

Operating Instructions Rope Pull Switches RPS... Safety rope pull switch RPS Correct use In accordance with EN 60947-5-5, EN ISO 13850, it must be ensured that parts of or complete industrial machines or installations can be stopped as quickly as possible

More information

Position switches FP series

Position switches FP series A Position switches FP series Selection diagram 0 08 8 9 0 0 0 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fiber glass rod gasket sphere sphere adjustable lever safety adjustable lever

More information

Prewired position switches FA series

Prewired position switches FA series Prewired position switches Technical data Housing Made of metal, coated with baked epoxy powder 2 m wired cable with 5x0,5 mm 2 wires marked SEV and IMQ Protection degree: IP6 General data Ambient temperature:

More information

Electromechanical pressure switches

Electromechanical pressure switches References : pages / and / page /5 Presentation Functions Pressure switches type XMX and XMA are switches for control circuits, with an adjustable differential. They are used to control the pressure of

More information

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073 Operating instructions Safety Rope Emergency Stop Switches UK ZB0052 / ZB0053 ZB0072 / ZB0073 7390878 / 02 03 / 2011 Contents 1 Safety instructions...3 2 Installation / set-up...4 2.1 Applications...4

More information

Zelio Relays RSL Slim Interface Plug-In Relays

Zelio Relays RSL Slim Interface Plug-In Relays Zelio Relays RSL Slim Interface Plug-In Relays Catalog 8501CT0901 2009 Class 8501 CONTENTS Description............................................. Page Introduction.................................................3

More information

Limit switches OsiSense XC Special For material handling applications, type XC1 AC

Limit switches OsiSense XC Special For material handling applications, type XC1 AC Presentation For material handling applications, type XC C b XC C with slow break contacts v With head for linear movement () 00_ 00_ 000_ Page / 00_ 00_ XCC XCC Page / XCC XCC / General characteristics

More information

Electromechanical pressure switches

Electromechanical pressure switches Presentation Electromechanical pressure switches OsiSense XM For power circuits, type XMP Presentation Pressure switches type XMP are switches for power circuits (direct switching), with an adjustable

More information

Prewired position switches FA series

Prewired position switches FA series 2 Prewired position switches FA series Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 51 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable lever 41 45

More information

XMPA12B2142 pressure sensor XMP - 12 bar - G 1/4 female - 2 NC - without control type

XMPA12B2142 pressure sensor XMP - 12 bar - G 1/4 female - 2 NC - without control type Characteristics pressure sensor XMP - 12 bar - G 1/4 female - 2 NC - without control type Main Range of product Pressure sensor type Pressure sensor name Pressure sensor size OsiSense XM Electromechanical

More information

TeSys protection components

TeSys protection components Presentation, description -pole thermal overload relays TeSys D Presentation TeSys D thermal overload relays are designed to protect a.c. circuits and motors against: b overloads, b phase failure, b excessively

More information

JUMO dtrans p30 Pressure Transmitter

JUMO dtrans p30 Pressure Transmitter 609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +49 661 600-0 Fax: +49 661 600-607 Phone: +44 179 6 55 Data Sheet 40466 Page 1/6 JUMO dtrans p0 Pressure Transmitter General application Pressure

More information

Safety Rope Pull Switches SR and SRM

Safety Rope Pull Switches SR and SRM Safety Rope Pull Switches SR and SRM Safety Rope Pull Switches For more safety on the production line Whether on the conveyor belt or on the machine when maximum safety is required, BERNSTEIN rope pull

More information

CMC Series Moulded Case Circuit Breaker Cielo Electric

CMC Series Moulded Case Circuit Breaker Cielo Electric Model name CMC: Series 225: mpere frame size Line side terminal In: Rated current Ue: Rated operational voltage Icu: Rated ultimate short-circuit breaking capacity Ta: mbient temperature In: 225 Icu: 55k@415V

More information

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0. LMP 07 Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % / 0. % FSO Nominal pressure from 0... mho up to 0... 50 mho Output signals -wire: 4... 0 ma -wire: 0...

More information

Types and approvals. Page 1/6. Data Sheet

Types and approvals. Page 1/6. Data Sheet Page 1/6 Panel-mounting Thermostats EM Series as: Protection temperature monitor STW (STB) Protection temperature limiter STB tested to DIN 3440 and Pressure Equipment Directive 97/23/EC Brief description

More information

Compact pressure switches for gas and air

Compact pressure switches for gas and air Compact pressure es for gas and air / 5.0 Printed in Germany Edition 0.8 Nr. 9 544 6 Technical description The pressure is an adjustable compact pressure according to EN 854 for combustion plants. The

More information

4/2 way Pneumatic Solenoid Valve

4/2 way Pneumatic Solenoid Valve 4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11

More information

CFSW. Hinges with built-in safety multiple switch

CFSW. Hinges with built-in safety multiple switch CFSW. Hinges with built-in safety multiple switch ELESA Original design Elesa Standards Main dimensions Fitting Weight Code Description L B f ±0.2 f 1 ±0.2 H h 1 h 2 d 3 d 4 C [Nm]# g 426601 CFSW.110-6-2NO+2NC-C-A

More information

ERS200. Safety Command Devices. Original Phone: operating instructions - Fax: Web:

ERS200. Safety Command Devices. Original Phone: operating instructions - Fax: Web: ERS200 Safety Command Devices EN 2011/07-607330 We reserve the right to make technical changes Original Phone: operating 800.894.0412 instructions - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

More information

EX-RECESSED CEILING LIGHT FITTINGS

EX-RECESSED CEILING LIGHT FITTINGS EX-RECESSED CEILING LIGHT FITTINGS RLF/RLF-INOX 250 18-58 W / RLF/RLF-INOX 250... N 18-36 W Metallic design for Zone 1 and Zone 21 The RLF... explosion-protected recessed ceiling light fittings with electronic

More information

Pull-rope emergency stop switch Type HENEX and SEGEX OPERATING INSTRUCTIONS

Pull-rope emergency stop switch Type HENEX and SEGEX OPERATING INSTRUCTIONS Pull-rope emergency stop switch Type OPERATING INSTRUCTIONS Legal Notice (Translation of the original) Document No.: 94.058 816.191 Pull-rope emergency stop switch, Type HENEX and SEGEX Product number:

More information

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119 Pressure switch type CS December 2001 DKACT.PD.P10.A2.02 520B1119 Introduction Pressure switch type CS is part of the Danfoss pressure control range. All CS pressure switches have a built-in pressure-operated,

More information

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0. Pressure Transmitter for Marine and Offshore Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0. % FSO Nominal pressure from 0... 40 mbar up to 0... 0 bar Output signals -wire:

More information

F series Foot Switches

F series Foot Switches F series Foot Switches ITC presents a complete line of foot switches from Bernstein, designed to respond to the most stringent requirements for machine control and safety applications. The F series includes

More information

Differential Pressure Control Types MP 54, MP 55 and MP 55A

Differential Pressure Control Types MP 54, MP 55 and MP 55A MAKING MODERN LIVING POSSIBLE Data sheet Differential Pressure Control Types MP 54, MP 55 and MP 55A MP 54 and MP 55 oil differential pressure controls are used as safety switches to protect refrigeration

More information

Differential pressure switch MP 54, MP 55 and MP 55A

Differential pressure switch MP 54, MP 55 and MP 55A Data sheet Differential pressure switch MP 54, MP 55 and MP 55A MP 54 and MP 55 oil differential pressure switches are used as safety switches to protect refrigeration compressors against low lubricating

More information

References, characteristics. References (1) Complementary characteristics not shown under general characteristics (page 30395/3)

References, characteristics. References (1) Complementary characteristics not shown under general characteristics (page 30395/3) References, characteristics Electromechanical pressure switches For power circuits, type XMP. IP degree of protection Size (87 psi). Adjustable differential, for regulation between thresholds Switches

More information

Differential pressure controls, Type MP 54, 55 and 55A

Differential pressure controls, Type MP 54, 55 and 55A MAKING MODERN LIVING POSSIBLE Technical brochure Differential pressure controls, Type MP 54, 55 and 55A MP 54 and oil pressure controls are used as safety switches to protect refrigeration compressors

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable

More information

Pressure switches for air and water CS

Pressure switches for air and water CS Data sheet Pressure switches for air and water CS CS pressure switches have a built-in pressure operated, three-pole switch. The contact position of which depends on the pressure in the connector and the

More information

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. Supplied with an electric input signal of 4 to 20

More information

High-performance submersible pressure transmitter For level measurement Model LH-10

High-performance submersible pressure transmitter For level measurement Model LH-10 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well

More information

Components for Pull Rope Systems. Leaflet No. Kiepe 680

Components for Pull Rope Systems. Leaflet No. Kiepe 680 Components for Pull Rope Systems Leaflet No. Kiepe 680 APPLICATION Pull ropes are used as actuators for operation of pull rope emergency stop switches along coveyor belts. The Kiepe pull ropes and accessories

More information

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up to SIL2 acc. to IEC 61508 Accessories

More information

Technical Data. Dimensions

Technical Data. Dimensions 00 Model Number Features mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and

More information

Climatic Independent Level Sensor LAR

Climatic Independent Level Sensor LAR 1 Product Information LAR-361 LAR-761 Climatic Independent Level Sensor LAR Application / Specified usage Authorizations Hydrostatic level measurement in humid ambiance Special applicable for exterior

More information

Gas density monitor With integrated transmitter Model GDM-100-TI

Gas density monitor With integrated transmitter Model GDM-100-TI SF 6 gas solutions Gas density monitor With integrated transmitter Model GDM-100-TI grid Products WIKA data sheet SP 60.05 for further approvals see page 5 Applications Gas density monitoring of closed

More information

compact ejector, Series ECM with Adjustable release pulse with silencer With filter vacuum switch: electronic 2 x PNP

compact ejector, Series ECM with Adjustable release pulse with silencer With filter vacuum switch: electronic 2 x PNP 00134428 Type Miniature compact injector Ambient temperature min./max. +0 C / +0 C Medium temperature min./max. +0 C / +0 C Working pressure min./max. 2. bar / 6 bar Medium Compressed air Max. particle

More information

Operating Instructions

Operating Instructions Operating Instructions Light-metal Ex d enclosures / flameproof enclosure > 8265/0 Empty enclosure > 8265/4 Control panel, integrated in Ex e enclosure > 8265/5 Control panel Table of Contents 1 Table

More information

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 00 Model Number Features 5 mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,

More information

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure Siemens AG 204 Overview The pressure transmitter SITRANS P220 measures the gauge pressure of liquids, gases and vapors. Stainless steel measuring cell, fully welded Measuring ranges 2.5 to 600 bar (36.3

More information

Meta-MEC Manual Motor Starters

Meta-MEC Manual Motor Starters Leader in Electrics & Automation Meta-MEC Manual Motor Starters Electric Equipment LG Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 45 mm 70 mm 63AF 100AF 3 LG Meta-MEC

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications

More information

Technical Data. Dimensions

Technical Data. Dimensions 00 Model Number Features Comfort series 30 mm non-flush Accessories MHW 0 Modular mounting bracket V-G Female connector, M, 4-pin, field attachable V-W-N-M-PUR Female cordset, M, -pin, NAMUR, PUR cable

More information

CFSW. Hinges with built-in safety multiple switch

CFSW. Hinges with built-in safety multiple switch CFSW. Hinges with built-in safety multiple switch ELESA Original design technical informations Material - Hinge body: self-extinguish high-rigidity SUPER-technopolymer, black colour. Resistant to solvents,

More information

Emergency Stop Devices/ Rope Pull Switches

Emergency Stop Devices/ Rope Pull Switches EN DE Emergency Stop Devices/ Rope Pull Switches Internationally successful the EUCHNER company Headquarters in Leinfelden-Echterdingen EUCHNER GmbH + Co. KG is a world-leading company in the area of industrial

More information

Operating Instructions

Operating Instructions LPL Series LED Pendant Lighting Operating Instructions IM0102 COOPER Electronic Technologies (Shanghai) Co., Ltd. No. 955 Shengli Road, East Area of Zhangjiang High-Tech Park, Shanghai 201201 China 1.

More information

Junction Boxes Series 8118

Junction Boxes Series 8118 > Enclosure in glass fibre reinforced polyester resin > 3 different sizes available with 4, 5 or as a junction box with integrated miniature fuse: 3 terminals and 1 miniature fuse 7 terminals and 1 miniature

More information

XML Electromechanical Pressure Switches

XML Electromechanical Pressure Switches Selection Guide Industrial Switches Type of installation ontrol circuits Applications Media controlled Type of operation Air, water, hydraulic oils, corrosive fluids, viscous products Fixed differential:

More information

Tightness controls TC 1 3 and TC 4

Tightness controls TC 1 3 and TC 4 Tightness controls TC 1 3 and TC 4 Test of both safety valves Short test period thanks to logical decision-making in the program sequence Adjustable test period which can be adapted to different systems

More information

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection SPOOL VALVES pilot operated single/dual solenoid (mono/bistable function) ISO 07-8 mm - pad mounting body M connection x/ - / - / Series 0 ISO 07- (8 mm) FEATURES M connection on top of valve: reduces

More information

2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version

2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version 2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version Type 6624 Impulse can be combined with... 10mm width orifice DN 0.8 to 1.2 with pressure range vacuum to 5bar medium separation, for

More information

Note: the lock-out circuit must be in accordance with Section 8.7 of DIN/VDE Twin thermostats ATH.-SW-2020 ATH.-SW-2070 ATH.

Note: the lock-out circuit must be in accordance with Section 8.7 of DIN/VDE Twin thermostats ATH.-SW-2020 ATH.-SW-2070 ATH. M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 3603 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-60 E-mail: mail@jumo.net Internet: www.jumo.net

More information

SonoMeter 30 Energy Meters

SonoMeter 30 Energy Meters Data Sheet SonoMeter 30 Energy Meters Description The Danfoss SonoMeter 30 is a range of ultrasonic, compact energy meters intended for measuring energy consumption in heating and cooling applications

More information

Relative pressure switch type 521

Relative pressure switch type 521 Relative pressure switch type 521 Pressure range 0... 2.5 600 bar The compact type 521 pressure switch is based upon the Huba Control developed thick film technology where the pressure measuring cell is

More information

Model range*1) Switching pressure difference

Model range*1) Switching pressure difference Pneumatic pressure switch electromechanical actuated -...00 bar, G/2 Microswitch with gold plated contacts Intrinsically safe operation Electrical connection: connector acc. to IN EN 7530-803 (form A)

More information

Pneumatic pressure switch 20DD

Pneumatic pressure switch 20DD Sensor system: stainless steel 0,2 to 6 bar Microswitch with gold plated contacts (suitable for intrinsically safe operation) High accuracy (max. scattering < 1,5%) Excellent sealing properties (better

More information

Conductor Bushings Series 8174

Conductor Bushings Series 8174 > Current lead-in for Ex d enclosures > 1 to 72 conductors combined in one current lead-in > Series screw-in plug-in > For voltages up to max. 1 V > For size conductor up to 7 mm 2 www.stahl.de 3163E The

More information

OPTIBAR P 1010 C Technical Datasheet

OPTIBAR P 1010 C Technical Datasheet Technical Datasheet Pressure transmitter with recessed diaphragm for general applications Wide variety thanks to modular design Measuring ranges up to 250 bar / 3750 psi High overload and temperature stability

More information

Meta-MEC Manual Motor Starters

Meta-MEC Manual Motor Starters www.lsis.biz Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 45 mm 70 mm 63AF 100AF 3 LS Meta-MEC Manual Motor Starters deliver more

More information

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview f gauge pressure Siemens AG 010 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection

More information

Differential pressure switch / Lube oil protection control MP 54 and MP 55

Differential pressure switch / Lube oil protection control MP 54 and MP 55 Data sheet Differential pressure switch / Lube oil protection control MP 54 and MP 55 MP 54 and MP 55 oil differential pressure switches are used as safety switches to protect refrigeration compressors

More information

Accessories for Progressive Systems

Accessories for Progressive Systems 1-0107-6-EN Accessories for rogressive Systems Cycle switches, cycle indicators, crossporting bars, overpressure indicators, spray nozzles rogressive feeder with cycle switch Electric overpressure indicator

More information

High-performance submersible pressure transmitter For level measurement Model LH-10

High-performance submersible pressure transmitter For level measurement Model LH-10 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well

More information

Pneumatic spool valve islands

Pneumatic spool valve islands Pneumatic spool valve islands P7.GB.R MEGA SPOOL VALVE ISLANDS MEGA pneumatic spool valve islands offer maximum performance along with flexibility, easy installation and simple operation. Due to their

More information

Expert Hydrostatic Level Transmitters

Expert Hydrostatic Level Transmitters Expert Hydrostatic s General Features MJK Expert hydrostatic level transmitters are designed for level measurement by submerging the transmitter in open channels, drains and tanks. Expert hydrostatic level

More information

better measurement Simply a question of

better measurement Simply a question of Simply a question of better measurement SCHMIDT Flow Sensor SS 20.600 The powerful industrial professional for demanding applications involving air and gases. Industrial processes Pneumatic technology

More information

C-Flow Coriolis Mass Flow Meters

C-Flow Coriolis Mass Flow Meters Coriolis Mass Flow Meters Ready for Take Off The New Compact C-Flow Küppers Elektromechanik GmbH The C-Flow The C-Flow Coriolis Mass Meters consist of two components: KCE Transmitter KCM Transducer 2 KEM

More information

Pressure switch and Thermostat CAS

Pressure switch and Thermostat CAS Data sheet Pressure switch and Thermostat CAS The CAS Series consists of a series of pressure controlled switches and temperature controlled switches. In this series, special attention has been given to

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.

More information

Operating Instructions

Operating Instructions Operating Instructions Ex d Enclosures in Light Metal / Flameproof Encapsulation > 8265/0 Empty Enclosure > 8265/4 controller, installed in Ex e enclosure > 8265/5 controller Contents 1 Contents 1 Contents...2

More information

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR SIT Group 836-837 TANDEM MULTIFUNCTIONAL GAS CONTROL MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR ALL ADJUSTMENTS ACCESSIBLE FROM ABOVE

More information

Available models Devices Color White sealing bellows Black sealing bellows NDT SW NDT GB NDT RT NDT GN NDT WS NDT BL NDT GR

Available models Devices Color White sealing bellows Black sealing bellows NDT SW NDT GB NDT RT NDT GN NDT WS NDT BL NDT GR Pushbuttons Left: type series N with sealing bellows, color white (standard). Right: type series N with sealing bellows, color black. Protective collar against unintentional actuation: refer to page 58

More information

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. An electric standardized signal of 4 to 20 ma or

More information

MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE

MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE SIT Group SIT -3- SIGMA MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE 9.955. Subject to change without notice Application Domestic gas appliances: central heating boilers, combi boilers, instantaneous

More information

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN Type 4708-45 Pressure Regulator for increased air capacity Fig. 1: Type 4708-45 Pressure Regulator Mounting and Operating Instructions EB 8546-1 EN Edition March 2010 Definition of the signal words used

More information

Climatic Independent Level Sensor LAR

Climatic Independent Level Sensor LAR 3 JAHRE GEWÄHRLEISTUNG 1 Product Information LAR-361 LAR-761 f o o d Climatic Independent Level Sensor LAR 3 3 Y R S W A R R A N T Y Application / Specified usage Authorizations Hydrostatic level measurement

More information

Pressure switch KP-E. Data sheet

Pressure switch KP-E. Data sheet Data sheet Pressure switch KP-E KP-E pressure switches for use in refrigeration and air conditioning systems are equipped with SPDT gold plated contacts and stainless steel bellows. The high pressure switches

More information

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm Dimensions 65 GW2 40 35 9 5 GW1 14 11 9 5.4 M20 x 1.5 0102 Model Number S M12 x 1.5 Features 77.5 LED V Direct mounting on standard actuators Compact and stable housing with terminal compartment connection

More information

Pressure Switch for gas and air

Pressure Switch for gas and air Switch for gas and air GAO-A4 GMH-A4 GML-A4 UL Listed UL 353 File # MH 16628 CSA Certified CSA C22.2 No. 13 and No. 0 Certification file # 201527 FM Approved Class 3510, 3530 File # J.I. 1Y919.AF Commonwealth

More information

Pressure Wave Switches. Profiles, push buttons, pressure cells and ground sensors for automatic doors, gates and barriers

Pressure Wave Switches. Profiles, push buttons, pressure cells and ground sensors for automatic doors, gates and barriers Pressure Wave Switches Profiles, push buttons, pressure cells and ground sensors for automatic doors, gates and barriers Maintenance free, robust, tried-and-tested Very fast closing Pressure wave technology

More information

Level switches Series LD Vibrating fork level switch for liquids and solids

Level switches Series LD Vibrating fork level switch for liquids and solids Level switches Series LD Vibrating fork level switch for liquids and solids Robust and compact Suitable for liquids (model LD61) and solids (model LD60) No moving parts, low maintenance Corrosion resistant

More information

Infrared Linescanners

Infrared Linescanners Thermal Imaging and Temperature Profiles for Continuous Process Monitoring and Quality Control HD Infrared Linescanners PROCESS & ANALYTICAL INSTRUMENTS Mountings and Accessories LSPHD Mountings and Accessories

More information

ED 701 Hygenic Pressure Transmitter

ED 701 Hygenic Pressure Transmitter ED 701 Hygenic Pressure Transmitter Hygienic process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response time < 25 ms (Option

More information

Differential pressure controls/ Lube oil protection controls MP 54 and MP 55 REFRIGERATION AND AIR CONDITIONING. Technical leafl et

Differential pressure controls/ Lube oil protection controls MP 54 and MP 55 REFRIGERATION AND AIR CONDITIONING. Technical leafl et Differential pressure controls/ Lube oil protection controls MP 54 and MP 55 REFRIGERATION AND AIR CONDITIONING Technical leafl et Contents Page Introduction... 3 Features... 3 Approvals... 3 Materials

More information

Proportional pressure regulators VPPE

Proportional pressure regulators VPPE Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/

More information

Installation, use and maintenance instructions. Gas burner (5)

Installation, use and maintenance instructions. Gas burner (5) Installation, use and maintenance instructions Gas burner MODEL GAS 4 TYPE 516 T80 291 (5) TECHNICAL FEATURES Thermal output 180-470 kw 154.800-404.200 kcal/h Fuel Natural gas Pci 8-10 kwh/m 3 = 7000-8600

More information

VMR VMR-OTN VMR 6 bar

VMR VMR-OTN VMR 6 bar VMR VMR-OTN VMR 6 bar Safety solenoid valves for gas Fast opening and fast closing type DN8 DN150 delta-elektrogas.com EE161-03/17 VMR VMR-OTN VMR 6 bar Safety solenoid valves for gas Fast opening and

More information

SOLENOID VALVES AND PNEUMATIC VALVES

SOLENOID VALVES AND PNEUMATIC VALVES 9 S E R I E S Electropneumatically and pneumatically operated valves Series 9 Assembly with sub-base (ISO 5599/1 Standards) Sizes 1, 2 and 3 The Series 9 electropneumatically or pneumatically operated

More information

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application: MV-01 2/2-way Solenoid Valve for Fluids Description: Features / Nominal diameters 1/4-2 / Pressure up to 10 bar / 24 V DC and all common AC variants / Forced-lifting The pilot-controlled full-way valve

More information

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm Dimensions M18x1 37 40 4 0102 24 LED Model Number Features 5 mm embeddable Usable up to SIL2 acc. to IEC 61508 Connection BN BU Accessories L+ L- EXG-18 Quick mounting bracket with dead stop BF 18 Mounting

More information

Electrical Sensing Edges

Electrical Sensing Edges sensing the future Electrical Sensing Edges Electrical sensing edges for safeguarding machinery & robots, automatic doors & gates, and public transportation Reliable, proven, long lasting Wide variety

More information

Pressure Switch for gas and air GGAO-A4

Pressure Switch for gas and air GGAO-A4 Pressure Switch for gas and air GGAO-A4 CSA Certified CSA C22.2 No. LR 53222 Certification file # 201527 Commonwealth of Massachusetts Approved Product Approval code G3-0106-191 Gas pressure switch Codes

More information

Climatic Independent Level Sensor LAR

Climatic Independent Level Sensor LAR 3 JAHRE GEWÄHRLEISTUNG SENSORS FOR FOOD AND BIOPHARMA. Product Information LAR-361 LAR-761 FOOD Climatic Independent Level Sensor LAR Application / Specified usage Hydrostatic level measurement in humid

More information

Pressure transmitter PASCAL Ci4

Pressure transmitter PASCAL Ci4 Pressure transmitter PASCAL Ci4 for general application,type Series CI4100 Features Pressure transmitter for the measuring of relative and absolute pressures of gases, vapors and liquids High-resolution

More information

EPIC Rectangular Connector Inserts. HBE Series. Technical Data Number of Contacts:

EPIC Rectangular Connector Inserts. HBE Series. Technical Data Number of Contacts: HBE Series HBE series inserts provide reliable termination and performance in the vast majority of medium power and control applications. Methods of termination include screw, crimp, and spring cage clamp.

More information