TECHNICAL SPECIFICATION

Size: px
Start display at page:

Download "TECHNICAL SPECIFICATION"

Transcription

1 lifting anchor system The T-slot The T-slot lifting anchor system...1 Introduction...2 The T-slot anchor...3 The O-anchor...3 The P-anchor...3 The TKS rod-anchor...3 The TPA plate-anchor...3 The TKA tilting -anchor...3 The TSG bended T slot anchor...3 Characteristics...3 T slot anchor...3 P anchor...3 O anchor...3 The TKA tilting-anchor...3 TKS Anchor...3 The TH 2 lifting hook...3 Lifting under a angle...3 Checking measurements by reasons of wear to the lifting hook...3 Attachment of the lifting anchors in the concrete...3 The ball socket RB...3 The SRB-socket...3 Ball socket SB...3 RR ring...3 RBP socket...3 Calculation of the T slot anchor...3 Lifting in an angle...3 Dynamic forces...3 Directions for stick factors...3 Anchoring of T slot anchors...3 Calculation example Table Calculation example Table Calculation example Table Calculation example Table Threat analysis...3 A 1/32

2 Introduction For the transportation lifting and mounting of concrete elements the best choice is to use the T-slot lifting anchor system. This lifting system is the safest method to transport concrete elements through the air. The speed of the use and a cheap T-slot anchor make the application of this lifting system to the most economic system. The T-slot lifting anchor system exists out of a in the concrete poured T-slot anchor with a reusable rubber ball and a TH 2lifting hook which can be used for a long time. TH 2 lifting hook T-slot anchor Reusable rubber recess former A 2/32

3 The T-slot anchor is built in the concrete element with the aid of the rubber ball. After the poring of the shuttering and the concrete is hardened, the rubber ball can be removed. In this formed hole the TH 2lifting hook fits exactly and the pre-fab element can be hoisted out of the shuttering The T-slot anchor The T-slot anchor is a metal bar from which the aft ends are formed by means of hot forging are thickened to a head and a foot. On the head the indication T with the maximum adjustable towing force is applied. The foot is specially designed to realize a good anchoring force in the concrete. To the head of the anchor the lifting hook is fitted during use. During the pouring of the concrete a reusable rubber ball is mounted to the head of the anchor, so that a bowl formed hole in the concrete remains. The anchor is produced according to a quality system and each charge is controlled en tested by an authorized institute. The tests have proved that there is only a crack after an at least 3 times higher force than the admissible force of the anchor. A 3/32

4 At collapsing of the concrete a dish formed foot arises of the T-slot anchor a break out cone with a incline of 1:3. This is an angle of about 35 º in relation to the length axle of the T-slot anchor. For the calculation of the anchor force a safety factor of 2.5 is set. Also see the tables in this leaflet. If a calculation of the anchor force does not offer enough security placement of an additional armament brings a higher admissible value. The already present armament usually does not give increasing of the anchor force For lifting anchors different types in the T-slot lifting anchor system can be used. Each type lifting anchor has his own field of use and is developed on a base of similar dimensions, for which always the TH 2 lifting hook can be used The O-anchor The O-anchor is provided with a hole, in which a armament hairpin can be placed to obtain a good anchoring in small elements The P-anchor The P-anchor is specially developed for the application in combination with special rubber slots. These lifting anchors are often used in pits, on which the holes are firmly mounted on the under jig and remain on the jig during the breaking away. The P-anchor is a good alternative for the use of the T-slot anchors in fixed steel holes for which a rubber ring brings the necessary clamping, so that during the pouring the anchor remains on his place. The TKS rod-anchor The TKS rod-anchor is provided with a ribbed rod to which a good anchoring can be obtained. For situations in which an anchoring foot cannot be used, a TKS rod-anchor with a adjusted length can arrange a sufficient anchoring. Especially in very small elements such an anchoring is the best solution. The TPA plate-anchor A 4/32

5 The TPA plate-anchor is provided with a footplate with which at a small built-in depth still a good anchoring can be obtained. By adding additional armament over the plate the anchoring force can be improved. The plate-anchors are used in thin floor plates or where longer T-slot anchors cannot be used. The TKA tilting -anchor The TKA tilting -anchor is specially developed for the placement or tilting of wall elements. By its specific form and in combination with a special slot form the TH 2 lifting hook is supported by the TKA tilting anchor itself. In this way no damages occur on the concrete element and still the TKA tilting anchor can be used. The TSG bended T slot anchor For special applications it can be necessary that a standard T slot anchor is bended, so that the anchoring point lays more in the element. For sandwich constructions the lifting point can be adjusted in the center of gravity although the anchoring must be created in the thickest part. A 5/32

6 T slot anchor Characteristics Characteristics of T-slot anchors Anchor Admissible Length Ø A Ø B Ø C type load [kn] T T T T T T T T T T T T T T T T T T T T T T T T T T T T T Anchor Admissible Length Ø A Ø B Ø C type load [kn] T T A 6/32

7 T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T A 7/32

8 Anchor type Admissibl e load [kn] Length Ø A Ø B Ø C T T T T T T T P anchor P-anchor type Characteristics of P anchors Axial Length load [kn] Ø A Ø B P P P P O anchor O Anchor type Characteristics of O anchors Axial load [kn] Length Ø A Ø B Ø C O O O O O O O O The TKA tilting-anchor A 8/32

9 TKA-anchor type Characteristics of TKA anchors Axial Load [kn] Length L Ø D1 Ø d TKA TKA TKA TKS Anchor Characteristics of the TPA anchors P-anchor type Axial load [kn] Length H Ø A Ø L x B d Characteristics of TKS anchor TPA Length l x 70 6 TKS-anchor TPA Axial Length 25 L (anchoring) Ø d 70 Ø A x 70 6 type load [kn] TKS TPA x 150 TKS TPA x 90 TKS TKS TPA x 90 8 TKS TPA x 90 TKS TKS TPA x 90 8 TKS TPA 100- TKS x TKS A 9/32

10 The TH 2 lifting hook Anchor type TH 2 13 TH 2 25 TH 2 50 TH 2 75/100 TH 2 150/20 0 TH TH Characteristics of TH 2 lifting hooks Admiss ible A B C D E F G load [kn] The TH 2 lifting hook is a special lifting hook, which is mounted in the slot of the head of the T slot anchor. The big advantage of this lifting system is that the TH 2 lifting hook when lifting under an angle the side force directly changes in the concrete to a pressure force. The slot anchor is hardly submitted to a side force whereby no reduction of the adjustable force has to be applied. A 10/32

11 Lifting under an angle Lifting angles Angle α to concrete [º] Addition factor in force in the lifting part When lifting under a angle there has to be taken into account the enlarging of the forces in the lifting cable. The force has to be multiplied with the factor, which is mentioned in the above table. When the angle in relation to the concrete is smaller than 30º the forces in the lifting cable will increase in such a way that it will beneath. In that case another solution has to be found f.i. longer lifting cables. The use of the TH 2 lifting hook is simple and the coupling is a quick simple action. If the lifting hook is coupled to the T slot anchor, lifting is possible. Advisable is to bring the lip of the TH 2 lifting hook in between the lifting cable and the concrete. In that case when loading under a angle the lip will be pushed to the concrete. For tilting in the air there has to be taken into account that the lip of the TH 2 lifting hook will be pushed to the concrete and not that the possibility arises that the ball of the lifting hook can turn out of the socket in the concrete. The TH 2 lifting hook is standard with an individual certificate according to European norms with which the user for 4 years only visually checks has to be taken for detecting any abnormality and checking if the wear measurements are not over or under passed. A 11/32

12 Checking measurements by reasons of wear to the lifting hook has to be done regularly (at least once a year according to this table IN CASE OF EXCEEDING: DISAPPROVAL TYPE Wear measurements H MAXIMUM M MINIMUM TH TH TH M TH 2 75/100 TH 2 150/200 TH 2 320/ H The TH 2 lifting hook has a safety factor for breaking of 5 After testing of the TH 2 lifting hook with a sample load of 3 times the admissible load, a separate number is punched on the lifting hooks, which is the same as the numbers on the test certificates. The original certificate belongs to the buyer. Copies are saved in the test institute and at Terwa BV. After 4 years the TH 2 lifting hooks have to be tested again independently of the use. A 12/32

13 Attachment of the lifting anchors in the concrete To couple the TH 2 lifting hook to the T slot anchor there must be a socket in the concrete. This socket has a ball form en can be as well as well a half ball and a small ball slot. Different aiding kits are available to realize this socket. For a half ball socket the TH 2lifting hook can be attached in any direction and eventually can turn during lifting in the socket till the lifting hook has arrived its good position. Most usable is the ball socket RB The ball socket RB Dimensions of the ball socket RB Type R A B Ø C RB 13 kn RB 25 kn RB 50 kn RB 75/100 kn RB 150/200 kn RB kn The ball socket RB has a ball form and can be mounted to the formwork with the aid of the attached IP inlay plate, which is applied with thread. The inlay plate can be mounted to the formwork with for instance a bolt. The inlay plate as well as the fixing bolt is available with speed thread In the case that the T slot anchor has to be placed in the concrete at a point with lack of space a smaller socket can be used, the SRB-socket. This socket is just big enough to mount the TH 2 lifting hook to the head of the T slot anchor, but the lifting hook cannot turn any more to all directions The SRB-socket Dimensions of the ball socket SRB Type R M N C SRB 25 kn SRB 50 kn SRB 75/100 kn SRB 150/200 kn SRB 320/450 kn ON DEMAND Beside in rubber the sockets can also be delivered in steel and hard plastic. The SB socket also is deliverable with and without magnets A 13/32

14 Ball socket SB Characteristics of SB ball socket Type D a b c SB M SB M SB M To the SB socket belongs the RR ring. This ring is mounted behind the head of the T slot anchor and has the function of sealing as well to clamp the T slot anchor in the steel ball RR ring Characteristics of RR ring RR ring type D1 D2 T SB SB SB In cooperation with clients as an alternative for the steel SB balls special fixed rubber sockets are developed. These can be used easily in combination with the P anchors without the necessity of a RR ring. The RBP sockets can be fixed on the formwork in such a way that only a P anchors has to be inserted and this one clamps on the second collar of the anchor. A 14/32

15 RBP socket For other specific solutions we can inform you. In cooperation with a number of clients a lot of problems has been solved, such as the mounting possibilities with magnets and the quick thread applications A 15/32

16 Calculation of the T slot anchor The best way of calculating the lifting anchors is step by step. The following steps are in the correct sequence: Determine the weight of the element By a well positioning of the anchors the same loading per anchor can be realized. In the case that one anchor is heavier loaded the anchor has to be chosen for this loading. It is better to apply anchors of the same kind per lifting situation Determine the lifting angle of the hoist cable in relation to the length axle of the lifting anchor. This depends on the adjusting of the length of the hoist cables and the position of the lifting anchors. After determining the lifting angle the calculation factor follows via the table for the force in the lifting cable. Estimation has to be made of the appeared dynamic forces as a result of the lifting or transport method. Lifting with a stationary crane with a fine hoist possibility reduces these forces, while the forces will be increased enormously when lifting in the terrain with a forklift truck. Determine via the table below with which enlargement factor has to be calculated. Lifting in an angle Angle α to concrete [º] Addition factor in force in the lifting part Dynamic forces During the detaching out of the formwork dynamic forces will arise. The size of the dynamic forces depends on the form of the element, the formwork and the use of additions for the detaching out of the formwork. The table gives some directions for the enlargement factor, which can be used. Situation Push factor In a factory with a fixed crane 1,1 to 1,3 Transport with a forklift truck at a flat floor 1,3to1,6 At location with a fixed crane At location with a drivable crane 1,3to1,5 1,5to1,7 Transport with a dredger at an uneven floor 1,6 to 2,0 In extreme cases > 2.0 A 16/32

17 Directions for stick factors Take account of o Oiled formwork o Taking away the side formwork Form of the element Stick factors Beam or pillar 1.0 to 1.10 Vertical plate 1.10 to1.15 Horizontal plate 1.2 to1.25 Floor plates with cassettes > 2.0 For elements with a difficult form higher factors have to be taken, especially for elements where a vacuum can arise during the taking out, such as with cassette floors. The forces can be a multiple of the weight. The action forces per anchor can be calculated as follows: Action Force = (weight x lifting angle factor x bumping factor x stick factor)/ (qty of anchors) When the action force of the heaviest loaded lifting is determined the choice of the type of the lifting anchor must be made. By means of the acting forces the type of the T slot anchor can be determined. With the aid of the added tables can be determined which length of the T slot anchor must be used dependably of the present concrete strength. When lifting in an angle by using T slot anchors no reduction is needed on the permissible load. For the vertical setting of small elements split armament can be necessary by reason that the pressing force of the lifting hook will lead directly his forces into the concrete. In these cases it is good to work with the TKA tilt anchors Split armament can be adjusted in the following way The lifting hook directly leads the pressing force to the concrete and starts approximately half way of the ball socket. That is why the split armament must be applied. See the drawing. A 17/32

18 Anchoring of T slot anchors If the loading type of the T slot anchors has been chosen the length of the anchor has to be determined. Dependably of the form of the element en the strength of the concrete at the first loading a T slot anchor has to be chosen that realizes a larger anchoring force, than is calculated as the acting force. The admissible anchoring force is calculated with a safety factor of 2,5. The foot of the T slot anchor obtains the anchoring. At collapsing of the concrete a dish formed foot arises of the T-slot anchor a break out cone with an incline of 1:3.that is why that relatively small anchoring lengths will do. In this leaflet tables are added, to which in practice most of the situations can be filled in. It is also possible to make an exact calculation of the present situation. On request special tables can be made which fulfils the practical situation at the prefab mill or at the building place. If it is possible to divide elements in the below groups then the following rule of thump can be used. In case of inexperience with the T slot anchor system additional information is always obtainable at Terwa. Type of element: Beams: T slot anchors with the standard length per loading type can be used. Horizontal plates T slot anchors with a smaller length than standard can be used Vertical plates T slot anchors with a larger length than standard must be used Overview of T slot anchor length Loading class [kn] Standard type T-slot anchor Often used shortened T-slot anchor Often used lengthened T-slot anchor 13 T T T T T T T T T T T T T T T T T T T T T T T T T T T All deliverable types of T slot anchors are mentioned in the product documentation and the pricelist and can be delivered in bright, thermic zinced or stainless steel A 18/32

19 The calculation of the anchoring length can be done with the aid of empiric found formulas, with the VBC- 90 or according to the rules being in preparation of the CUR-working group Anchors in concrete. When calculating the admissible anchoring force besides the length of the T slot anchor the present concrete strength is of main importance. Mostly the deforming strength is leading or the concrete strength that is realized at the first loading of the anchors. If any doubt about the admissible concrete force or that by any reason it is not possible to realize additional measurements have to be taken. For instance the concrete force can be enlarged in the location of the T slot anchor by adjusting isolation material, where by higher temperatures in the concrete gives a quicker force development. The addition of extra armament in the armament nets almost never leads to improvement of the anchoring force. Only if the armament is placed around and over the foot of the anchor the anchoring force can increase The anchoring force of the T slot anchor is the biggest when the T slot anchor is placed at a distance to the edge which is 3 times bigger than the built in depth so that a complete break out cone an be created. If it is not possible to have an edge distance to all directions of 3 times the built in depth a better anchoring must be obtained with the aid of a longer T slot anchor. In the table a situation is described which fulfill as well the edge distances in all directions of 3 times bigger the built in length as the situation for which the edge distance is limited to 2 directions. With the aid of these tables a good impression can be obtained of what the real admissible force is in situations that are more or less comparable. In case of any doubt, please contact Terwa. A 19/32

20 For vertical plates must taken into account the possibility that a horizontally break out can occur. Here also the present vertical armament has no effect for the anchoring force. The situation in the sketch becomes very critical if the thickness of the element is smaller than half of the chosen T slot anchor. In this situation additional discussion with Terwa is necessary. To enlarge the vertical anchoring a hairpin can be adjusted which falls around the foot. Also in this situation it is very helpful to use the TKA tilting anchor, an eye anchor or a rod anchor. With these lifting anchor the anchoring is obtained by an armament hairpin through the eye of the anchor or by a ribbed rod. All in this leaflet mentioned situations are valid for most of the cases. For variant situations or elements for which this instruction cannot be used you always can get advice from Terwa. A 20/32

21 Calculation example 1 Floor element: Dimensions 5.00 x 2.00 x0.20 m³ 4 T-slot anchors Concrete strength class B45 Strength at deboxing 20 N/mm² Situation at the works: The element will be taken out of the box with a portal crane. There is worked with an equator to prevent that the angle to the concrete becomes smaller than 75 º. The to be used lifting anchor factor will be Also will be taken into account: A push factor of 1.3 and a Stick factor of 1.2 Situation at the building area: The element will be built up with the aid of a turning crane. There is worked with 2 hooks equator to prevent that the angle to the concrete becomes smaller than 60 º. The to be used lifting anchor factor will be Also will be taken into account: A push factor of 1.3 Determination of the weight: G= 5.00 x 2.0 x 0.2 (m³ x 25 kn/m³) = 50 kn Determination of the arisen force per anchor: At the works: Force per anchor: F = at the building area 50 x 1.04 x1.3 x1.2 = 20.3 kn normative 4 50 x 1.16 x1.3 Force per anchor: F = = 18.9 kn 4 The situation at the works during deboxing is for the choice of the loading class normative T -Slot anchor: T -25 kn Determination of the length of the T Slot anchor" A 21/32

22 According to the Table the T Slot anchor Type T already will do at a concrete strength of 20 N/mm². According to rule of thumb for a Floor element normally a T Slot anchor in shortened implementation can be used. In this case also a T or a T can be chosen. Terwa B.V. can execute for you a special calculation, for which the exact anchoring length can be calculated Final conclusion. The floor element can be hoisted with 4 T Slot anchor Type T in black, zincked or in stainless steel. Choosen positions: Length direction: ca. 1/5 of the length = 1,00 m from the edge Transverse direction: ca. 30% of the width = 0,50 m from the edge A 22/32

23 Table 1 Admissible break out forces for bottom plates This table is value for the mentioned T-slot anchors at the condition that the distance to the edge of the element is more than 3 times the built in depth or for heavy T-slot anchors a minimum distance of 500 mm The in the table indicated values are the minimum anchor forces at indicated concrete strength in N/mm² Built in Concrete strength at first load: [kn] Anchor type depth 10 N/mm² 15 N/mm² 20 N/mm² 25 N/mm² T > 13 > 13 T > 13 > 13 > 13 > 13 T > 13 > 13 > 13 > 13 T >25 >25 T >25 >25 >25 >25 T >25 >25 >25 >25 T T >50 >50 >50 >50 T >50 >50 >50 >50 T >75 >75 T >75 >75 >75 >75 T >100 >100 T >100 >100 For heavy T-slot anchors a minimum distance of 500 mm is applicable T >150 >150 T >150 >150 T T >200 T T A 23/32

24 Calculation example 2 Façade element: Dimensions 5.00 x 2.00 x0.20 m³ 4 T-slot anchors for deboxing 2 T-slot anchors for transport and mounting Concrete strength class B45 Strength at deboxing 20 N/mm² Situation at the works: The element will be taken out of the box with a portal crane with the in example 1 calculated T-slot anchors. In free storage the façade element will be brought to a vertical position (attention be careful for damages of the edge or use a TKA anchor. At bringing in a vertical position there is worked with an equator to prevent that the angle to the concrete becomes smaller than 75 º. Hereby rests the element still on the floor, so that the T-slot anchors only hoist half of the weight. Only when the element is in a vertical position it can be hoisted and the T-slot anchors will be loaded with the full weight. That is why the bringing of the element into a vertical position is not a normative loading. Also when deboxing and directly bringing into a vertical position with the aid of 2 T-slot anchors to the front side will not give a normative loading as well. While lifting with an equator: The angle to the concrete is about 90º The to be used lifting anchor factor will be Also will be taken into account: A push factor of 1.3 and a Stick factor of 1.2 (only by reason of the deboxing, so not normative. A 24/32

25 Situation at the building area: The element will be built up with the aid of a turning crane. There is worked with 2 hooks equator to prevent that the angle to the concrete becomes about 60 º. The to be used lifting anchor factor will be Also will be taken into account: A push factor of 1.3 Determination of the weight: G= 5.00 x 2.0 x 0.2 (m³ x 25 kn/m³) = 50 kn Determination of the arisen force per anchor: At the works: Force per anchor: F = At the building area Force per anchor: F = 50 x 1.00 x 1.3 x = 39 kn 50 x 1.16 x1.3 = 37.7 kn 2 The situation at the building area is for the choice of the loading class normative T -Slot anchor: T -50 kn Determination of the length of the T Slot anchor" According to the Table the T Slot anchor Type T already will do at a concrete strength of 20 N/mm². (Minimum anchoring force Z= 32.9 kn) According to rule of thumb for a facade element normally a T Slot anchor in extra long implementation can be used. In this case also a T or a T can be chosen. Terwa B.V. can execute for you a special calculation, for which the exact anchoring length can be calculated Final conclusion. The facade element can be hoisted with 2 T Slot anchor Type T in black, zincked or in stainless steel. Chosen positions: Length direction: ca. 1/5 of the length = 1,00 m from the edge Transverse direction: in the middle of the material thickness Table 2 Admissible break out forces for façade plates & beams A 25/32

26 This table is value for the mentioned T-slot anchors at the condition that the distance to the edge of the element is more than 3 times the built in depth and the anchor is built in the middle of the material thickness a minimum distance of 500 mm The in the table indicated values are the minimum anchor forces at indicated concrete strength in N/mm² Concrete strength at first load: [kn] Anchor type Built in depth Wall thickness 10 N/mm² 15 N/mm² 20 N/mm² 25 N/mm² 30 N/mm² T T > 13 > 13 T > 13 > 13 > 13 T > 13 > 13 > 13 > 13 > 13 T T >25 T >25 >25 T >25 >25 >25 >25 T T T T >50 >50 T >50 >50 T >50 >50 >50 >50 T T T >75 >75 T >75 >75 >75 T T T >100 >100 >100 T >100 >100 >100 >100 T T T T T Calculation example 3 A 26/32

27 Determination of the maximum weight Starting points: Façade element: For the transportation 2 T-slot anchors are put in the front side For deboxing use 4 T-slot anchors or bringing the element in vertical position with the 2 T-slot anchors in the front side(attention be careful for damages of the edge) Strength at deboxing 15 N/mm² Situation at the works: In free storage the façade element will be brought to a vertical position (attention be careful for damages of the edge or use a TKA anchor At bringing in a vertical position there is worked with an equator to prevent that the angle to the concrete becomes smaller than 75 º. The angle to the concrete is about 90º The to be used lifting anchor factor will be Also will be taken into account: Push factor = 1.3 Determination of the arisen force per anchor G max. x 1.00 x1.3 Arisen force: F = 2 anchors In table 3 an overview of the maximum weights has been given for the façade elements when using 2 T- slot anchors of the in the first column mentioned types. For all the cases in between or divergent positions Terwa B.V. can make a special calculation or make a special table for your works. A 27/32

28 Determination of the arisen force per anchor: At the works: 50 x 1.00 x1.3 x1.2 Force per anchor: F = = 39 kn 2 At the building area: 50 x 1.16 x1.3 Force per anchor: F = = 37.7 kn normative 2 The situation at the building area is for the choice of the loading class normative T -Slot anchor: T -50 kn Determination of the length of the T Slot anchor" According to the Table the T Slot anchor Type T already will do at a concrete strength of 20 N/mm². (Minimum anchoring force Z= 32.9 kn) According to rule of thumb for a Floor element normally a T Slot anchor in extra long implementation can be used. In this case also a T or a T can be chosen. Terwa B.V. can execute for you a special calculation, for which the exact anchoring length can be calculated Final conclusion. The floor element can be hoisted with 2 T Slot anchor Type T in black, zincked or in stainless steel. Chosen positions: Length direction: ca. 1/5 of the length = 1,00 m from the edge Transverse direction: in the middle of the material thickness A 28/32

29 Table 3 Maximum weights of façade plates and beams This table is mentioned for the T-slot anchors as described under the condition that the distance to the edge of the element in 2 directions is more than triple of the built in depth and that the anchor is positioned in the middle of the material thickness Also the distance between the T-slot anchors must be more than 6 times of the built in depth the in the table mentioned values are the maximum weights of the elements at a concrete strength of 15 N/mm². With this the use of an equator as well as a push factor are indicated Anchor type Built in depth Wall thickness Arisen force per anchor [kn] Maximum weight of the element with 2 anchors [kn] T T T T T T T T > T T T T T T T T T T T T T T T T T T T T When the concrete strength at first lifting has another value as 15 N/mm² of course the maximum weight of the elements are different At indication other tables can be made. Calculation example 4 Façade element: Determination of the maximum weight A 29/32

30 Starting point For the transportation 2 T-slot anchors are put in the front side For deboxing use 4 T-slot anchors or bringing the element in vertical position with the 2 T-slot anchors in the front side(attention be careful for damages of the edge) Strength at deboxing 35 N/mm² Situation at the works and at the building area: In free storage the façade element will be brought to a vertical position (attention be careful for damages of the edge or use a K2 kip anchor. At bringing in a vertical position there is worked with a spring is used with a top angle smaller than 60 º. The to be used lifting anchor factor will be Also will be taken into account: Push factor = 1.3 For deboxing other T-slot anchors are used. That is why no stick forces have to be taken into account. Also when the bringing in vertical position from out the box is used then also the stick forces are not normative, because of only the halve of the forces have to be taken into account Determination of the arisen force per anchor G max. x 1.16 x 1.3 Arisen force: F = 2 anchors In table 4 an overview of the maximum weights has been given for the façade elements when using 2 T- slot anchors of the in the first column mentioned types. For all the cases in between or divergent positions Terwa B.V. can make a special calculation or make a special table for your works. Table 4 Maximum weights of façade plates and beams This table is mentioned for the t-slot anchors as described under the condition that the distance to the edge of the element in 2 directions is more than triple of the built in depth and that the anchor is positioned in the middle of the material thickness Also the distance between the T-slot anchors must be more than 6 times of the built in depth The in the table mentioned values are the maximum weights of the elements at a concrete strength of A 30/32

31 35 N/mm². At bringing in a vertical position there is worked with a spring is used with a top angle smaller than 60 º. Maximum Arisen force per Built in depth Wall thickness weight of the Anchor type anchor element with 2 [kn] anchors [kn] T T T T T T T T T T T T T T T T T T T T T T T T T T T T When the concrete strength at first lifting has another value as 35 N/mm² of course the maximum weight of the elements are different At indication other tables can be made. Threat analysis Threat Mechanical threat by finger injuries at screwing in hoisting noose Mechanical threat by finger injuries at screwing in hoisting noose in the transport anchor Overload of the transport anchor by wrong hoisting direction Overload of the transport anchor caused by not using a transverse or equator Risk Counter measurements S C: One and two hand operation is possible; at least: trained personnel at works and at the building area S UI: suggestion for put down the elements on blocks S S UI: load values have taken into account wrong hoisting directions UI: load values have taken a 3 times safety factor for such mistakes A 31/32

32 S= small UI=user instruction ==================== A 32/32

TYPE: LSF - LIFTING STUD FOOT ANCHOR DESCRIPTION: The design of the anchor means no additional reinforcement is required as the forces are transferred into the concrete from the design of the foot of the

More information

TECHNICAL MANUAL. COPRA Anchoring Coupler. For Smart Bolted Connections

TECHNICAL MANUAL. COPRA Anchoring Coupler. For Smart Bolted Connections TECHNICAL MANUAL Anchoring Coupler For Smart Bolted Connections Version: PEIKKO GROUP 03/2017 Anchoring Coupler For bolted connections Multi-purpose anchoring system for all bolted connections Simplifi

More information

DICTATOR "DIREKT" Gate Closer

DICTATOR DIREKT Gate Closer DICTATOR "DIREKT" Gate Closer For Access Gates in Boundary Fences The DICTATOR gate closer DIREKT is the economic solution for the reliable and controlled closing of outside gates, such as admission gates

More information

The cost-efficient fixing for flexible use in non-cracked concrete VERSIONS. zinc-plated steel stainless steel hot-dip galvanised steel

The cost-efficient fixing for flexible use in non-cracked concrete VERSIONS. zinc-plated steel stainless steel hot-dip galvanised steel The cost-efficient fixing for flexible use in non-cracked concrete VERSIONS APPROVALS zinc-plated steel stainless steel hot-dip galvanised steel BUILDING MATERIALS Approved for: Concrete C20/25 to C50/60,

More information

DICTATOR "DIREKT" Gate Closer

DICTATOR DIREKT Gate Closer DICTATOR "DIREKT" Gate Closer For Access Gates in Boundary Fences The DICTATOR gate closer DIREKT is the economic solution for the controlled closing of outside gates, such as admission gates to kinder

More information

Utility Anchor System

Utility Anchor System Utility Anchor System The Dayton Superior Utility Anchor System is designed to economically simplify the lifting and handling of precast concrete elements. Its economics, ease of use and versatility will

More information

PHOENIX, ARIZONA USA

PHOENIX, ARIZONA USA NEW PRODUCTS MODEL: US-AASS-80 DESCRIPTION: Cantilever Arm 80 MEETS OSHA & ANSI Z359.14 CLASS B 1-800-850-5914 PHOENIX, ARIZONA USA WWW.ULTRASAFEUSA.COM CANTILEVER ARM The Ultra-Safe cantilever arm has

More information

Fatigue Resistant Sockets for Dynamic Loads PFEIFER Cable Structures. Cable structures technology Info Nr PFEIFER SEIL- UND HEBETECHNIK GMBH

Fatigue Resistant Sockets for Dynamic Loads PFEIFER Cable Structures. Cable structures technology Info Nr PFEIFER SEIL- UND HEBETECHNIK GMBH Fatigue Resistant Sockets for Dynamic Loads Cable Structures Cable structures technology Info Nr. 3 4-2012 SEIL- UND HEBETECHNIK GMBH DR.-KARL-LENZ-STRASSE 66 D-87700 MEMMINGEN TELEPHONE +49 (0) 83 31-937-393

More information

Quattrocycle BV. Quattrocycle. User Manual. Last update February Quattrocycle BV Bremkant EJ Middelbeers. User Manual Quattrocycle 1

Quattrocycle BV. Quattrocycle. User Manual. Last update February Quattrocycle BV Bremkant EJ Middelbeers. User Manual Quattrocycle 1 Quattrocycle User Manual Last update February 2010 Quattrocycle BV Bremkant 6 5091 EJ Middelbeers User Manual Quattrocycle 1 Table of Contents Page Chapter 1: Introduction 3 Chapter 2: Instructions for

More information

Operating manual Mobile Man Anchor IM-200 Reference No. IM 200

Operating manual Mobile Man Anchor IM-200 Reference No. IM 200 Operating manual Mobile Man Anchor IM-200 Reference No. IM 200 EN 795:1996 class E Table of contents: 1. Description of the Mobile Man Anchor... 2 2. Construction of the Mobile Man Anchor.... 3 3. Technical

More information

Highbond anchor FHB II-A S

Highbond anchor FHB II-A S Highbond anchor FHB II-A S The best performance in cracked concrete with the least installation effort VERSIONS APPROVALS zinc-plated steel stainless steel high corrosion-resistant steel ADVANTAGES BUILDING

More information

RB70 Automatic Diluent Valve Maintenance Manual. Version 1.1 November 2006 Written by Tino de Rijk. Page 1 of 23

RB70 Automatic Diluent Valve Maintenance Manual. Version 1.1 November 2006 Written by Tino de Rijk. Page 1 of 23 RB70 Automatic Diluent Valve Maintenance Manual Version 1.1 November 2006 Written by Tino de Rijk Page 1 of 23 Table of Contents 1. Introduction... 3 2. ADV diagram and parts list (Pre June 2006)... 4

More information

Also suitable for: Concrete C12/15. For fixing of: Steel constructions Railings Consoles Ladders Wooden constructions Cable trays Machines Staircases

Also suitable for: Concrete C12/15. For fixing of: Steel constructions Railings Consoles Ladders Wooden constructions Cable trays Machines Staircases 28 Highbond anchor FHB II Flexible installation and highest loads in the cracked tensile zone. OVERVIEW FHB II-A S (standard), zinc plated steel FHB II-A L (performance optimised), zinc-plated steel Resin

More information

MAINTANCE MANUAL CNC ROTARY TABLE MODEL: DMNC-5C YUASA INTERNATIONAL.

MAINTANCE MANUAL CNC ROTARY TABLE MODEL: DMNC-5C YUASA INTERNATIONAL. MAINTANCE MANUAL CNC ROTARY TABLE MODEL: DMNC-5C YUASA INTERNATIONAL. INDEX DESCRIPTION PAGE (1)SPECIFICATION 2 (2)OUTSIDE DIMENSION LAYOUT 3 (3)INSPECTION REPORT 4 (4)PREPARATION FOR OPERATION 5 4-1.LUBRICATING

More information

RATCHET RELEASE SHACKLE

RATCHET RELEASE SHACKLE RATCHET RELEASE SHACKLE INNOVATIVE PILING EQUIPMENT HYDRAULIC PILING HAMMERS EURO RATCHET RELEASE SHACKLE FOR STEEL ERECTION OPERATORS INSTRUCTIONS & SPARE PARTS LIST EXCAVATOR MOUNTED VIBRATORS EXCAVATOR

More information

TRAVSMART permanent single-cable horizontal lifeline system

TRAVSMART permanent single-cable horizontal lifeline system The Travsmart single-line system provides a smooth travel. It allows the traveler to move freely over the intermediate anchors, minimizing wear and eliminating user assistance. The user s hands remain

More information

TENSOREX C+ TENSOREX C+

TENSOREX C+ TENSOREX C+ Installation instruction TENSOREX C+ TENSOREX C+ is a new spring automatic tensioning device for tramway, light and heavy railways Overhead Contact Lines ( OCL ). TENSOREX Products are only by PFISTERER

More information

E Manual Self tacking system 30

E Manual Self tacking system 30 597-205-E 2015-12-09 Manual Self tacking system 30 1 Self tacking system 30, 443-200-10 A self-tacking jib makes life on board a lot easier, in particular for shorthanded crews. The jib sheet is led to

More information

pneumatic power clamps

pneumatic power clamps pneumatic power clamps Features Király Trading KFT H-1151 Budapest Mogyoród útja 12-14 E-mail:_agi@kiralytrading.hu Your requirements Power element of machines, tools and devices for the following applications:

More information

Floor Mount Socket. T: +44 (0) F: +44 (0)

Floor Mount Socket. T: +44 (0) F: +44 (0) G-Davit : Floor Mount Socket USER INSTRUCTION MANUAL A davit socket for installation bolted to a high strength flooring material. Suitable for both fall arrest use and lifting. EN795 Class B, PPE Anchor

More information

Benefits. caused by overloading Quick. tester. ons. Applicati HAP 1.15 HAP safety. shackle. After activation safety shackle.

Benefits. caused by overloading Quick. tester. ons. Applicati HAP 1.15 HAP safety. shackle. After activation safety shackle. HAP 1.15 Hoist Anchor Plate Benefits No limitation in load direction, hookk (shackle) can rotate and swivel, symmetric design of base plate withh 4 anchors Design fits application requirements of dynamic

More information

Advantage Lockers & Bike

Advantage Lockers & Bike Advantage Lockers & Bike Advantage Bike Racks & Lockers Inc. is the #1 supplier of Storage Lockers and Bike Racks to the Lower Mainland s residential construction industry. With 25+ years of experience

More information

Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

Overview of types.   T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2) Technical data sheet R3015-..-..-B2 / R3020-..-..-B2 Characterised control valves, 6-way, with internal threads Two sequences (cooling/heating) With a rotary actuator 90 Water-side switching or modulating

More information

Assembly Instructions. -Cantilever Boat Lifts

Assembly Instructions. -Cantilever Boat Lifts Assembly Instructions -Cantilever Boat Lifts Winch Instruction Page Safety Information 1. The winch is built for the multipurpose of hauling and lifting operations. It is not to be used as a hoist for

More information

Injection mortar FIS VL

Injection mortar FIS VL Injection mortar FIS VL The solid injection mortar for standard applications in cracked concrete and masonry High-bay warehouses BUILDING MATERIALS Approved for anchorings in: Concrete C20/25 to C50/60,

More information

Installation and Operation Instruction Manual

Installation and Operation Instruction Manual Installation and Operation Instruction Manual Toggle Lok Anchor - Model #7442 Portable Concrete Anchorage Connector ANSI Z359.1 5,000 lbs / 22.24 kn FallTech, Inc 1306 Alameda Street Compton, CA 90221

More information

LOAD-BEARING SHEETS SAFETY ANCHOR SA

LOAD-BEARING SHEETS SAFETY ANCHOR SA www.ruukki.com LOAD-BEARING SHEETS SAFETY ANCHOR SA 113-153 INSTRUCTIONS FOR USE Contact Information Please see your local contact information from www.ruukki.com Figure 1. Cross-section of the safety

More information

MSA Confined Space Entry Equipment

MSA Confined Space Entry Equipment MSA Confined Space Entry Equipment Because every life has a purpose... MSA Confined Space Entry Equipment MSA XTIRPA Manhole Guard System Use for confined space vertical entry and fall protection when

More information

K13.12 FACE FIXED PANIC EXIT DEVICE K13 DOORS

K13.12 FACE FIXED PANIC EXIT DEVICE K13 DOORS K13 DOORS K13.12 FACE FIXED PANIC EXIT DEVICE 01.03.2018 Waregemstraat 5-9870 Zulte - Belgium - T. +32 9 388 88 81 - F. +32 9 388 88 21 - commercial@sobinco.com - www.sobinco.com CONTENTS 1. Base set n

More information

fischer Epoxy Mortar FIS EB The basic epoxy mortar for applications in concrete

fischer Epoxy Mortar FIS EB The basic epoxy mortar for applications in concrete fischer Epoxy Mortar FIS EB The basic epoxy mortar for applications in concrete For standard applications in concrete and rebar connections. Advantages at a glance Epoxy mortar for applications in concrete

More information

Load Ring bolted > VWBG < in pink

Load Ring bolted > VWBG < in pink RUD-Art.-Nr.: 8503693-EN / 03.014 Load Ring bolted > VWBG < in pink EN Safety instructions This safety instruction/declaration has to be kept on file for the whole lifetime of the product. Translation

More information

WIRE ROPE PULLING MACHINE

WIRE ROPE PULLING MACHINE WIRE ROPE PULLING MACHINE Spare parts list and exploded view Specifications Dimensions Item No. 0.8T 1.6T 3.2T 5.4T Rated Capacity kg 800 1600 3200 Rated Forward Handpower N 343 441 441 Rated Forward Travel

More information

PR4 Installation, Operation & Maintenance Instructions (DOT Certification Included)

PR4 Installation, Operation & Maintenance Instructions (DOT Certification Included) PR4 Installation, Operation & Maintenance Instructions (DOT Certification Included) March 2006 Form FVC 054 Rev. 6 KEEP THIS DOCUMENT WITH THE PRODUCT UNTIL IT REACHES THE END USER. The Passive - R4 device

More information

Fall Arrest Anchor Solutions

Fall Arrest Anchor Solutions Y O U L L N E V E R B E B E T T E R P R O T E C T E D Fall Arrest Anchor Solutions EACH TYPE TESTED AT THE NATIONAL ENGINEERING LABORATORY Roofanka and Ridganka CE approved to the PPE Directive COMPREHENSIVE

More information

Fig. 3.1 (not to scale)

Fig. 3.1 (not to scale) 1 Fig. 3.1 shows an early water-powered device used to raise a heavy load. The heavy load rests on piston B. cylinder A cylinder B water load piston A piston B connecting rod connecting rod pivot beam

More information

Technical information for hinges

Technical information for hinges 451 452 Technical information for hinges In the tables on the following pages are listed a large range of hinge variations. Many more variations are possible if hinges with guide tabs are required i.e.

More information

DESIGN OF AXIALLY LOADED STEPPED FOOTING DATA :- SBC of soil =200 KN /m 2 Concrete Mix =M20 Steel Grade = Fe 415 Clear cover of bottom slab =50 mm

DESIGN OF AXIALLY LOADED STEPPED FOOTING DATA :- SBC of soil =200 KN /m 2 Concrete Mix =M20 Steel Grade = Fe 415 Clear cover of bottom slab =50 mm STEPPED FOOTING The construction of sloped footing is sometimes difficult and when the slope of the top face of footing is more, say more than 1 vertically to 3 horizontally, it may be difficult to finish

More information

Installation Instructions MODEL VSTI-A020 Tank Indicator Installation Model: VSTI-A020, Stainless Reverse Read System Versa Steel Inc. Guide Cables No

Installation Instructions MODEL VSTI-A020 Tank Indicator Installation Model: VSTI-A020, Stainless Reverse Read System Versa Steel Inc. Guide Cables No Tank Indicator Installation Model: VSTI-A020, Stainless Reverse Read System Guide Cables No Guide Cables 1 August 4, 2011 Assembly Instructions: (Shown with a 2 board, 12 ft kit) ITEM NO. PART NUMBER DESCRIPTION

More information

Tapped Hole (.375) Tapped hole 15 (.594) (.391±.004) Frame 19±0.2 (.750±.008) 12.7±0.2 (.500±.008) 19±0.2 (.750±.008) R S 4 x Ø 5.4 (.

Tapped Hole (.375) Tapped hole 15 (.594) (.391±.004) Frame 19±0.2 (.750±.008) 12.7±0.2 (.500±.008) 19±0.2 (.750±.008) R S 4 x Ø 5.4 (. 434 Lift-off In-line Zinc can also be 31.5 19.1 (.750) For Lift-Off For on Lift-Off 1300 (300 lbf) 2200 (500 lbf) 56 T.P.I. (2.21) 31.5 19.1 (.750) Tapped hole Ø 9.5 (.375) ultimate 3300 (750 lbf) 9300

More information

Planning and general precautions ithrust Tunnel Systems installations.

Planning and general precautions ithrust Tunnel Systems installations. Version 1.0 This recommendation will go through the different factors to consider when choosing where and how to fit thruster tunnels in a boat. Some of these recommendations might be difficult, or even

More information

Float operated valve TYPE (SWDS)

Float operated valve TYPE (SWDS) Float operated valve TYPE (SWDS) Assembly and Operating Instructions for all models Float operated valve Type SWDS Assembly and Operating Instructions Rev.0 Page 1 of 12 Table of Contents 1 General 3 2

More information

Davorin Matanović DRILLING LINE (ROPE) AND BLOCKS

Davorin Matanović DRILLING LINE (ROPE) AND BLOCKS Davorin Matanović DRILLING LINE (ROPE) AND BLOCKS DRILLING LINE (ROPE) AND BLOCKS The term drilling line pertain to the wire rope made from steel wires. It is spooled onto the drum of the draw works hoist,

More information

fischer Epoxy Mortar FIS EB

fischer Epoxy Mortar FIS EB fischer Epoxy Mortar FIS EB The basic epoxy mortar for applications in concrete ETA-15/0771 ETAG 001-5 Post-installed rebar connection (TR2 fischer Epoxy Mortar FIS EB: For standard applications in concrete

More information

Chapter 2 Rigging. Cutting Wire Rope. Anchoring Wire Rope to Drum. Winding Wire Rope Onto Drum

Chapter 2 Rigging. Cutting Wire Rope. Anchoring Wire Rope to Drum. Winding Wire Rope Onto Drum Chapter 2 Rigging Cutting Wire Rope The wire rope must be tightly seized on both sides of the point where the wire rope will be cut, as shown in Figure 2-1. Seize the wire rope with either seizing wire

More information

Medium Voltage Switchgear. Installation Manual for Pressure Relief Ducts

Medium Voltage Switchgear. Installation Manual for Pressure Relief Ducts Uniswitch Medium Voltage Switchgear Installation Manual for Pressure Relief Ducts TABLE OF CONTENTS 1 Summary... 1 2 Transportation and storage... 2 2.1 Condition on delivery... 2 2.2 Unpacking at installation

More information

G F T German Formwork Technology. Climbing Bracket CB 240. Assembly and Application Guide

G F T German Formwork Technology. Climbing Bracket CB 240. Assembly and Application Guide German Formwork Technology F o r m w o r k S u p p o r t S y s t e m s S e r v i c e s Climbing Bracket CB 240 Assembly and Application Guide Product Information & Features Contents Product Information

More information

Lectric Cycles Mid-Drive Electric Motor Installation

Lectric Cycles Mid-Drive Electric Motor Installation Lectric Cycles Mid-Drive Electric Motor Installation This write-up describes the installation of a Lectric Cycles electric motor. The model is the e-rad Mid-Drive 750 Watt conversion kit, installed on

More information

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly. Components preparation and pressure adjustment ABP Overview ABP is a component that enables boosting by s only up to twice primary pressure (.0MPa max.) in combination with using air tank but not using

More information

Installation and Training Manual

Installation and Training Manual AirForce1 Tower Kit Installation and Training Manual FuturEnergy Limited Ettington Park Business Centre Stratford upon Avon CV37 8BT +44 (0)1789 451070 Table of Contents Safety Notes... 3 Parts Supplied

More information

Operating instruction for the quick-change tap holders type:

Operating instruction for the quick-change tap holders type: type: HF 20 HF 30 Date of edition: 15.07.2008 Stage of alteration: 4 Please keep this for future use! Contents: 1 Application range, safety instructions and technical data... 3 1.1 Application range,

More information

Name of product: Gripper for vertical façade FTV panels Types: PVF (60, 80, 100, 120, 133, 150, 172, 200 and 240 mm) INSTRUCTIONS FOR USE

Name of product: Gripper for vertical façade FTV panels Types: PVF (60, 80, 100, 120, 133, 150, 172, 200 and 240 mm) INSTRUCTIONS FOR USE Name of product: Gripper for vertical façade FTV panels Types: PVF (60, 80, 100, 120, 133, 150, 172, 200 and 240 mm) INSTRUCTIONS FOR USE CONTENTS INTRODUCTION - GENERAL INFORMATION 3 Purpose of instructions

More information

Erection, maintenance and disposal Inverted installation. Zinc oxide silicone-housed surge arresters PEXLIM R-X, Q-X and P-X

Erection, maintenance and disposal Inverted installation. Zinc oxide silicone-housed surge arresters PEXLIM R-X, Q-X and P-X Erection, maintenance and disposal Inverted installation Zinc oxide silicone-housed surge arresters PEXLIM R-X, Q-X and P-X 1 Important information The following instruction is valid for PEXLIM R-X, PEXLIM

More information

THOR 10 HAMMER CAGE INSTRUCTIONS

THOR 10 HAMMER CAGE INSTRUCTIONS 75 " 7m 78 4" m 6" 8.8m 45 ".70m 4.9deg 6 4" 6m 44 4".67m 75 " 7m 9 4" 0m 44".m 497 4".64m The 70, Thor Hammer Cage, consists of four heavy duty aluminum net poles. The unique pole structure reduces the

More information

INSTRUCTIONS & MAINTENANCE SHEET PORTABLE HYDRAULIC PUNCHING HEAD PH045

INSTRUCTIONS & MAINTENANCE SHEET PORTABLE HYDRAULIC PUNCHING HEAD PH045 INSTRUCTIONS & MAINTENANCE SHEET PORTABLE HYDRAULIC PUNCHING HEAD PH045 V05.2013 DECLARATION OF CONFORMITY 2 1. TECHNICAL CHARACTERISTICS Maximum punching capacity: Min / Max. hole diameter: Max. yield

More information

SECTION 2 RING MOUNT

SECTION 2 RING MOUNT SECTION 2 RING MOUNT Rotax aircraft engines are manufactured and supported by Rotax GmbH of Austria. Read and understand the Rotax manuals completely before starting with the engine installation, as they

More information

ASSEMBLY AND OPERATING MANUAL LTW MAXI TRENCH BOX

ASSEMBLY AND OPERATING MANUAL LTW MAXI TRENCH BOX Manufacturer: LTW Tiefbauvertriebs GmbH Holter Weg 11 D 41836 Hückelhoven-Brachelen Phone: +49 (0) 24 62 / 2009 0 Fax: +49 (0) 24 62 / 2009 15 e-mail: info@ltw-verbau.de homepage: http:\ \ www.ltw-shoring.com

More information

ASSEMBLY AND OPERATING MANUAL LTW SHORING BOXES VB 100 & VB 120

ASSEMBLY AND OPERATING MANUAL LTW SHORING BOXES VB 100 & VB 120 Manufacturer: LTW Tiefbauvertriebs GmbH Holter Weg 11 D 41836 Hückelhoven-Brachelen Phone: +49 (0) 24 62 / 2009 0 Fax: +49 (0) 24 62 / 2009 15 e-mail: info@ltw-verbau.de homepage: http:\ \ www.ltw-shoring.com

More information

XTS-Impact. XTS-Terminal (hold)

XTS-Impact. XTS-Terminal (hold) XTS-Impact The XTS-Impact is used to support the XTS-Linked system, as a standalone anchorage point and as an anchorage point in horizontal temporary lifeline systems. The anchorage point is tested according

More information

User Instructions. Installing Fall Protection Void Formers. Please read carefully before fixing anchorage components into formwork

User Instructions. Installing Fall Protection Void Formers. Please read carefully before fixing anchorage components into formwork Installing Fall Protection Void Formers. Please read carefully before fixing anchorage components into formwork May 2016 Installing moulds into the formwork. Scissorsafe Insert Moulds are cast into the

More information

Opening Angle 76º 30º [337] 45º 76º 30º [213] 45º 76º 30º [169] 45º 76º 30º [337] 45º 76º 30º [337] 45º 76º 30º [128] 45º 76º 30º [404] 45º 76º 30º

Opening Angle 76º 30º [337] 45º 76º 30º [213] 45º 76º 30º [169] 45º 76º 30º [337] 45º 76º 30º [337] 45º 76º 30º [128] 45º 76º 30º [404] 45º 76º 30º 17.22 Picture Force N [lbs] Opening Angle Weight Opening/closure time min 84A3-310000000 84A3X310000000 84A3Y310000000 84A3Z310000000 60º 1,35 84A3-0000000 84A3X0000000 950 84A3Y0000000 [213] 84A3Z0000000

More information

markilux markilux Technical Information safe timeless beautiful markilux Collection Specification markilux 1700 markilux 1700 stretch markilux

markilux markilux Technical Information safe timeless beautiful markilux Collection Specification markilux 1700 markilux 1700 stretch markilux safe timeless beautiful pergola 215 Installation of and awning systems (in line EN 13561) and pergola systems intended for outdoor use meet the requirements of European Standard EN 13561 for blinds and

More information

Deluxe Gourd Racks I D E G A. Parts List. Shown above are parts for the two-level, Deluxe Gourd Rack (DGR 12V)with 12 arms for vertically hung gourds.

Deluxe Gourd Racks I D E G A. Parts List. Shown above are parts for the two-level, Deluxe Gourd Rack (DGR 12V)with 12 arms for vertically hung gourds. Deluxe Gourd Racks H F K I D E J C G A Shown above are parts for the two-level, Deluxe Gourd Rack (DGR V)with arms for vertically hung gourds. Parts List Code Quantity A B C D E F G H I J 6, or 4 6, or

More information

Technical Data Sheet TI-F50 Locking Units series KFH

Technical Data Sheet TI-F50 Locking Units series KFH English translation of German original Locking Units series KF Further important practical advice is given in Operating Manual BA-F50., Rod diameter 18 mm 50 mm øz 8 L 2 6 x 6 0 min. 4x30 KF 18 to KF 32,

More information

Vibration isolation system 1VIS10W. User manual

Vibration isolation system 1VIS10W. User manual Vibration isolation system 1VIS10W User manual Standa 2014 Table of contents 1. General information 3 1.1. Introduction 3 1.1.1. Safety 5 1.2. Location of the table 5 1.3. Air supply requirements 5 2.

More information

HELM Hinging facility according to EN 795:2012 Typ D. Sliding hardware

HELM Hinging facility according to EN 795:2012 Typ D. Sliding hardware HELM Hinging facility according to EN 795:2012 Typ D Sliding hardware Contents General Information General Information Page 3 Certification Page 4 Technical Information HELM Track profile Page 7 HELM Bends

More information

Miller DuraHoist Safety Systems

Miller DuraHoist Safety Systems Portable Confined Space System designed for manhole and confined space entry/ retrieval and fall arrest applications. Portable Fall Arrest Post provides three independent swivel tie-off points for fall

More information

MSA Latchways Ladder System

MSA Latchways Ladder System Systems overview 1 of 13 Important information Individuals or organisations carrying out the installation of a MSA Latchways ladder fall protection system shall read, understand and follow these instructions

More information

Extension Platform. Base Platform. Crossover. Exit railing. Exit Railing

Extension Platform. Base Platform. Crossover. Exit railing. Exit Railing Base Platform Galvanized With metal grate and two brackets Railing on the long side and a face side Extension Platform Galvanized With metal grate and one bracket Railing on the long side with rail connection

More information

CATALOG INDEX. Removable Anchors. Toggle Anchors. I-Beam Anchors. Steel Slings. MegaSwivel Family. Swivel Kits. Mining Anchors.

CATALOG INDEX. Removable Anchors. Toggle Anchors. I-Beam Anchors. Steel Slings. MegaSwivel Family. Swivel Kits. Mining Anchors. 2015 CATALOG CATALOG INDEX Removable Anchors P3 Toggle Anchors P6 I-Beam Anchors P7 Steel Slings P11 MegaSwivel Family P13 Swivel Kits P14 Mining Anchors P22 Ladder Rescue Kit P19 Contact P21 REMOVABLE

More information

It allows you to. is the Best Option. More information at

It allows you to. is the Best Option. More information at Document - 17AIO Launch and Retrieve by yourself without getting your partner wet Copyright C Release & Retrieve Boat Latch Pty Ltd, 2016 and "L-&-R" is a Trademark of Release & Retrieve Boat Latch Pty

More information

A. TO PREPARE THE MACHINE FOR USE.

A. TO PREPARE THE MACHINE FOR USE. INSTRUCTION MANUAL FOR THE ML120 STRINGING MACHINE. CONTENTS: A. TO PREPARE THE MACHINE FOR USE. 1. The assembly of frame with console and tooltray. 2. Fixing the lever of the tension unit. 3. Putting

More information

PF30 Inspection & Maintenance Manual

PF30 Inspection & Maintenance Manual PF30 Inspection & Maintenance Manual Version 1.4 (September 2011) 1 Contents 1. Warning!!!!!!!!!! 3 2. Terminology! Figure 1: POWERFAN PF30 and Drope!!!! 4! Figure 2: POWERFAN PF30 with belt guard retracted!!

More information

Kennel-Gear Plastic Bowl System

Kennel-Gear Plastic Bowl System Kennel-Gear Plastic Bowl System Product Information Our Kennel-Gear 20oz plastic bowls are constructed of durable polypropylene and are dishwasher safe. The kits come with a bowl and Kennel Bar Mount.

More information

KM/31000 (Stainless steel end plates) Air bellows, single acting

KM/31000 (Stainless steel end plates) Air bellows, single acting KM/ (Stainless steel end plates) > > Ø... / inch (... mm) > > Very easy to install no alignment problems > > Almost frictionless operation > > No maintenance or lubrication > > Typical applications; actuator,

More information

Model: 7200 Collegiate Volleyball System

Model: 7200 Collegiate Volleyball System Model: 7200 Collegiate Volleyball System Installation, Operation and Maintenance Instructions Please read all instructions before attempting installation or operation of these units SAVE THESE INSTRUCTIONS

More information

Specialists in HTM Medical Gas Pipeline Equipment AVSU/Module Operating and Maintenance Instructions

Specialists in HTM Medical Gas Pipeline Equipment AVSU/Module Operating and Maintenance Instructions The Area Value Service Units and Module format (AVSU) provide a local gas isolation facility for use during normal installation and maintenance or in the event of an emergency. They are built in accordance

More information

Made in the USA. For Fall Protection Only. SafeLok Part Description

Made in the USA. For Fall Protection Only. SafeLok Part Description Operations and Instruction Manual SafeLok Anchorage - Model # 4011 IM-0051 REV A Portable Concrete and Steel Anchorage Connector ANSI Z359.1-07 5,000 lbs / 22kn Made in the USA The 3/4 Fall Protection

More information

SAFETY JOURNAL FOR GIPFEL WEDGE ROCK ANCHOR BOLTS

SAFETY JOURNAL FOR GIPFEL WEDGE ROCK ANCHOR BOLTS SAFETY JOURNAL FOR GIPFEL WEDGE ROCK ANCHOR BOLTS NOTE: Here we are only talking about the wedge type expansion bolts. How do rock anchors fail? A rock anchor assembly mainly comprises of a Hanger and

More information

ASSEMBLY AND OPERATING MANUAL LTW SHORING BOXES VB 60

ASSEMBLY AND OPERATING MANUAL LTW SHORING BOXES VB 60 Manufacturer: LTW Tiefbauvertriebs GmbH Holter Weg 11 D 41836 Hückelhoven-Brachelen Phone: +49 (0) 24 62 / 2009 0 Fax: +49 (0) 24 62 / 2009 15 e-mail: info@ ltw-verbau.de homepage: http:\ \ www.ltw-shoring.com

More information

mechanical APPLICATION

mechanical APPLICATION mechanical APPLICATION Many SWAROVSKI ELEMENTS, such as Rivets, Jeans Buttons, Snap Fasteners, Decorative Buttons and Magnet Fasteners, can be applied manually or mechanically, using either semi- or fully

More information

SERIES A24 RAISED RIB

SERIES A24 RAISED RIB SERIES A24 RAISED RIB Eurobelt Series A24 Raised Rib conveyor belt has been designed mainly to be used with finger plates. It has ribs that, sticking out 6 mm above the module, provide a greater resistance

More information

Heavy Equipment & Rigging Specialist Training

Heavy Equipment & Rigging Specialist Training Heavy Equipment & Rigging Specialist Training Module 1 Unit 4: Intro to Rigging May08 1 Key Points Review of Exercise Goals Discuss Rigging Components Language of Crane Signals Review Anchor Installation

More information

LIQUIP DRYBREAK COUPLER. API800 Series MAINTENANCE INSTRUCTIONS

LIQUIP DRYBREAK COUPLER. API800 Series MAINTENANCE INSTRUCTIONS LIQUIP DRYBREAK COUPLER API800 Series MAINTENANCE INSTRUCTIONS API LOADING COUPLER TO API RP1004 June 2015 Issue: F M:\Product-Info\API8xx\6-Service-Maintenance\API800 MAINTENANCE INSTRUCTIONS 40183.doc

More information

ASSEMBLY INSTRUCTIONS S O L O N STANDARD MODULES

ASSEMBLY INSTRUCTIONS S O L O N STANDARD MODULES ASSEMBLY INSTRUCTIONS S O L O N STANDARD MODULES SOLON Blue 230/07 SOLON Black 230/07 (01, 02) SOLON Blue 220/03 (01, 07) SOLON Black 280/10 SOLON Black 300/10 SOLON P220/6+/07 SOLON M230/6+/07 (01) SOLON

More information

Belt strength. Available the belt. (kg/m) PP - Polypropylene 2, to [B] PE - Polyethylene 1, to [B]

Belt strength. Available the belt. (kg/m) PP - Polypropylene 2, to [B] PE - Polyethylene 1, to [B] SERIES E20 FLAT TOP Eurobelt Series E20 Flat Top, due to a closed surface configuration, is the suitable conveyor belt for those applications in which it is not necessary any drainage through the belt

More information

FITNESS, SAFETY & MEDICAL SUPPLIES

FITNESS, SAFETY & MEDICAL SUPPLIES COMMERCIAL SERIES LIFTS TABLE OF CONTENTS 1. TRI-Point Anchor System 2. TRI-Point Paver Instruction Anchor Method 3. TRI-Point Retro-Fit Anchor System 4. TRI-Point Drop In Anchor System 5. Commercial Series

More information

Ground Release Shackle

Ground Release Shackle Operator Manual Subhead Advantages: In the process of installing Slide Rail, the shackle connecting the top of posts, panels, and sheeting must be removed manually. This is normally done by climbing on

More information

BC Shackle. Made in the China. Alloy Steel Anchor Shackle. Instructions for handling and use - Please read in full before using this device

BC Shackle. Made in the China. Alloy Steel Anchor Shackle. Instructions for handling and use - Please read in full before using this device BC Shackle Made in the China Alloy Steel Anchor Shackle Instructions for handling and use - Please read in full before using this device Index 1.) Introduction 2.) Warnings / General Use Guidelines 3.)

More information

CORPORATE SAFETY MANUAL

CORPORATE SAFETY MANUAL CORPORATE SAFETY MANUAL Procedure No. 32-0 Revision: Date: May 2005 Total Pages: 10 PURPOSE To provide general guidelines for the inspection of all ropes, chains, cables, slings, etc. used for personnel

More information

Before you start! Is iwalk 2.0 right for you?

Before you start! Is iwalk 2.0 right for you? Before you start! Is iwalk 2.0 right for you? Physical Abilities Requirements 1. Stair Test Before your injury, could you easily walk up and down stairs at normal speed, without using the hand rail? 2.

More information

Assembly, Installation and operating. instructions for. Söll-Xenon anchorage device

Assembly, Installation and operating. instructions for. Söll-Xenon anchorage device Assembly, Installation and operating instructions for Söll-Xenon anchorage device according to EN 795:1996 Part No: XE-... (The following must be completed by the operator in permanent waterproof ink.)

More information

8. Carefully layout all the parts of the reservoir setup and clean any dirt, grime or dust from the parts. ( image 8 ) 8

8. Carefully layout all the parts of the reservoir setup and clean any dirt, grime or dust from the parts. ( image 8 ) 8 INSTRUCTIONS TO SERVICE AMADAXTREME SHOCKS 2.0 REMOTE RES AUSTRALIAN VERSION PART 1 - SERVICE THE RESERVOIR 1.Prior to cleaning the shock check for any leaks or signs of damage to the res, lines, bushes

More information

Roughneck TM Mesh Slings

Roughneck TM Mesh Slings Roughneck TM Slings ROUGHNECK WIRE MESH SLINGS Widely used in metalworking shops and steel warehouses where loads are abrasive, hot or tend to cut web slings Features and Benefits Promotes Safety Steel

More information

PERSONAL FALL PROTECTION

PERSONAL FALL PROTECTION HORIZONTALLIFELINE PERSONAL FALL PROTECTION Personal Fall Protection Systems PERSONAL FALL PROTECTION SYSTEMS Personal fall protection systems are required when an operative is working at an elevated level

More information

GUKO FDA. einfach. gut. beraten.

GUKO FDA. einfach. gut. beraten. GUKO FDA Size : Ends : Min Temperature : Max Temperature : DN 25 to 300 Flanges PN10/16-25 C + 90 C Max Pressure : 16 Bars Specifications : Absorb vibrations and noise Linear and angular compansion Inner

More information

1500 Follow Spot Yoke

1500 Follow Spot Yoke 1500 Follow Spot Yoke Rev 1.1 2004 City Theatrical, Inc. Getting Started with the City Theatrical Follow Spot Yoke Congratulations on the purchase of your City Theatrical Follow Spot Yoke. The City Theatrical

More information

Round duct nozzle jet diffuser Model DSA-RR

Round duct nozzle jet diffuser Model DSA-RR Round duct nozzle jet diffuser Model DSA-RR Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3

More information

BANKSMAN / SLINGER. 1. What is the smallest size diameter of synthetic rope allowed for use as a hand held tagline?

BANKSMAN / SLINGER. 1. What is the smallest size diameter of synthetic rope allowed for use as a hand held tagline? BANKSMAN / SLINGER 1. What is the smallest size diameter of synthetic rope allowed for use as a hand held tagline? A. 16mm B. 10mm C. 12mm 2. What is the maximum temperature that a webbing sling can be

More information

LOAD CHARTS RT890E METRIC DIN / ISO / 75%

LOAD CHARTS RT890E METRIC DIN / ISO / 75% LOAD CHARTS RT89E METRIC DIN / ISO / 75% 232729 SERIAL NUMBER RT89E - S/N 232729 1 RT89E - S/N 232729 2 TABLE OF CONTENTS GENERAL NOTES...4 WEIGHT REDUCTIONS / LINE PULLS & REEVING INFO / RIGGING CHART

More information

3/4 SafeClaw Anchorage Connectors

3/4 SafeClaw Anchorage Connectors Operations and Instruction Manual Model #4075 Portable Concrete Anchorage Connector ANSI Z359.1-07 5,000 lbs / 22kn OHSA 1910.66 & 1926.502 Effective: 01/2012 Expires: 01/2022 IM-0049 REVA 3/4 SafeClaw