Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073
|
|
- Jonah Young
- 1 years ago
- Views:
Transcription
1 Operating instructions Safety Rope Emergency Stop Switches UK ZB0052 / ZB0053 ZB0072 / ZB / / 2011
2 Contents 1 Safety instructions Installation / set-up Applications Function and electrical connection Operating and display elements Installation Function Maintenance requirement Electrical connection Safety characteristics Technical data Scale drawing Accessories Standards Approvals / certificates
3 1 Safety instructions Follow the operating instructions. Non-observance of the instructions, operation which is not in accordance with use as prescribed below, wrong installation or incorrect handling can affect the safety of operators and machinery. For installation and prescribed use of the product the notes in the operating instructions must be carefully observed and the applicable technical standards relevant for the application have to be considered. Failure to observe instructions or standards, especially any tampering with and/or modification to the product, will void any manufacturer s liability. The unit must be installed, connected and put into operation by a qualified electrician trained in safety technology. After installation the system must be subjected to a complete function check. Disconnect the device externally before handling it. Also disconnect any independently supplied relay load circuits. For installation the requirements according to EN must be observed. In case of malfunction of the unit please contact the manufacturer. Tampering with the device can seriously affect the safety of operators and machinery. It is not permitted and leads to the exclusion of any liability and warranty claims. 3
4 2 Installation / set-up 2.1 Applications The safety rope emergency stop switch is used to provide safety-related switching statuses where large danger areas have to be secured and housings or covers are not possible. Typical applications are conveyor systems and rotating machines and large danger areas. The safety rope emergency stop switch meets the requirements of EN ISO 13850, IEC / EN and IEC / EN The safety rope emergency stop switch can be used in applications up to performance level e according to EN ISO NOTE 2.2 Function and electrical connection Make careful note of all information in the operating instructions of the safety rope emergency stop switch. This document provides all required instructions concerning installation, mounting, operation and maintenance. Important note The products described here are designed to be components of a safetyoriented machine or control system. A complete safety-related system normally includes sensors, evaluation units, signalling components and concepts for safe switch-off. It is the responsibility of each manufacturer of a machine or installation to ensure a correct functioning of the whole system. The manufacturer of the safety rope emergency stop switch, his subsidiaries and affiliates are not in a position to ensure all of the characteristics of a machine or product which was not designed by him. The manufacturer accepts no liability for any recommendation that may be implied or stated here. The warranty contained in the contract of sale is the sole warranty. Any statements contained herein do not create new warranties or modify existing ones. Compliance with the description of the operating instructions of the safety rope emergency stop switch is mandatory! 4
5 3 Operating and display elements 1: red E-stop 2: blue reset button 3: dual LED 4: rope tension indicator Rope tension indicator: Indicator shown with steel rope properly adjusted 5
6 4 Installation Installation must be carried out by authorised personnel. The safety rope emergency stop switch is mounted using four M5 screws. The tightening torque for the fixing screws is 4 Nm The tightening torque for the cover screws, the cable glands and cable seals is 1.5 Nm to ensure protection rating IP 67. Only use seals of the correct size for the cable entry and the external diameter of the cable. The maximum vertical pull force on the rope pull is 130N until activation, the max. travel 300mm. Enough space has to be provided so that the required actuation travel can be reached. Eye bolts have to be installed between the switches across the whole length of the rope at a distance of min. 2.5m to max. 3m. The first eyebolt must be mounted at a distance of max. 500mm of the switch eye bolt or the tension spring (if it is used). It is important to note that the first 500mm cannot be used as part of the active protected area (E-stop triggering). Installation of the components The tension of the rope is obtained by rope tensioner systems. After the installation the tension must be set to the middle position which is indicated by green arrows in the transparent window of the individual switches. Verify the function of all switches 6
7 and the control circuits by pulling on various spots on the rope in the active protected area and then resetting the individual switches by pressing the blue reset button. Ensure each time that the switches clip into place and have to be reset manually by pressing the blue button. If necessary, increase the rope tension until the tests along the active length of the area are satisfactory. The switches are equipped with a red, mushroom-shaped E-stop button. Check the individual emergency stop switches and reset them to ensure proper functioning of the control circuits. The typical operating conditions for a successful operation of the safety rope emergency stop system are: max. 75N pull force and max. 150mm bending of the rope between the eye bolts for rope support. Rope pull systems with single direction safety rope emergency stop switches are influenced by fluctuations of the ambient temperature! To ensure proper function of the rope pull system it is mandatory to take into account the dependence on the temperature when fixing the rope length and distance of the eye bolts (every 3m) C + 22 C + 20 C + 15 C + 10 C + 7,5 C + 5 C + 3 C Installation Temperature [ C] - 3 C - 5 C - 7,5 C - 10 C - 15 C - 20 C - 22 C - 25 C Rope Length 15m 30m 50m 60m 75m 100m 126m Installation Temperature in [ C] ± X [ C] = max. allowed rope length in [m] Not OK OK 7
8 5 Function Pulling the tensioned rope, rope breakage or impact on the E-stop cause activation of the switching function of the safety rope emergency stop switch. There is a window on the switch via which the correct rope tension can be monitored during setting and maintenance. Setting, troubleshooting and maintenance are made much easier. After activation of the E-stop function a latching mechanism maintains the E-stop command until it is unlocked manually by pressing the blue reset button. Before resetting the E-stop signal the cause of the activation has to be determined. Reset is only possible with correct rope tension (position indication in middle position). The max. rope length also depends on the change of the ambient temperature. Function of the safety rope emergency stop switch 5.1 Maintenance requirement Every week: Check proper functioning of the system at various spots along the rope length. Check the setting of the nominal rope tension and re-adjust it, if necessary. Every six months: Separate the voltage supply and remove the cover. Make sure that the screws are tight and check them for signs of penetrated moisture. Damaged or faulty devices are to be replaced! Repair is not permissible. 8
9 6 Electrical connection Wiring is only possible if the device is disconnected from power. Contact arrangement 0 mm 4.0 mm 15.0 mm 17.0 mm 4 NC + 2 NO Rope slack Tension range Rope pulled 11/12 21/22 33/34 41/42 51/52 63/64 contact open contact closed Contact travels safety rope emergency stop switch 24 V DC LED: + 24 V DC on terminal 1 -> LED display flashing red + 24 V DC on terminal 3 -> LED display permanently green 9
10 Installation sample: Programming sample: Data bits: Data bit D3 D2 D1 D0 In/Out SI-2 SI-2 SI-1 SI-1/O-1 Activated input channel Bit sequence D3-D0 SI-1 XX00 SI-2 00XX SI-1 and SI keiner XXXX Activated alarm outputs Bit sequence D3-D0 O-1 XXX1 X= random 10
11 110 V AC LED: 110 V AC on terminal 1 (red) -> LED display flashing red 110 V AC on terminal 3(green) -> LED display permanently green 0V on terminal 2 (black) Installation sample: 11
12 7 Safety characteristics Characteristics Performance level Value PL e Category cat. 4 MTTF d Mission time T 214 years 21 years PFH B10 d cycles at 100mA load These calculations were made on the basis of an ambient temperature of 40 C. The device meets the requirements of EN ISO : 2008 category 4 / PL e and can be used in applications up to PL e. For the PFD-/PFH values and the MTTF d values of the other components see the respective documentation. Explanation of the abbreviations: PL Performance Level Capability of safety-related parts to perform a safety function at predictable conditions to fulfill the expected risk reduction. PFH Probability of dangerous failure per hour Cat. Category Classification of the safety-related parts of a controller as regards their resistance to failures. T Mission time Max. service life B10 d MTTF d Mean Time To Dangerous Failure Number of cycles, up to 10% of the components with dangerous failure. 12
13 8 Technical data Electrical design Safety contacts Auxiliary contact Type of contact Contact material Switching capacity Max. switching voltage/switching capacity Minimum load Thermal current Rated Insulation voltage Short-circuit / overload protection 4 NC 2 NO snap-action contacts silver AC: 240 V/3 A, 120 V/6 A, inductive DC: 24 V/2.5 A, inductive 240 V/720 VA 5 V, 5 ma DC 10 A 500 V external fuse 10A (FF) Connection terminal up to 2.5 mm 2 Mechanical design Fixing elements Mounting position Cable entry Max. rope length Activation force (on rope) Tension force for operating position (axial) 4 x M5 screws as required 4 x M m < 125 N 130 N (between switches) Switching contacts to IEC / EN Mechanical life Function display Operation Error current load LED > 1,000,000 activations LED green LED red, flashing 15 ma Ambient temperature C Protection rating IP 67 Vibration resistance Hz Shock resistance 15g 11ms Housing material die-cast aluminium Housing colour yellow Weight 1100 g 13
14 9 Scale drawing ZB0052 / ZB0072 Dimension in mm ZB0053 / ZB0073 Dimension in mm 14
15 10 Accessories ZB0050: Safety rope e-stop switch with dual sided rope connection ZB0051: Safety rope e-stop switch with dual sided rope connection, LED 24 V DC ZB0051: Safety rope e-stop switch with dual sided rope connection, LED 110 V AC ZB0054: Rope tensioner kit, stainless steel, rope length 5 m ZB0055: Rope tensioner kit, stainless steel, rope length 10 m ZB0056: Rope tensioner kit, stainless steel, rope length 20 m ZB0057: Rope tensioner kit, stainless steel, rope length 50 m ZB0058: Rope tensioner kit, stainless steel, rope length 80 m ZB0059: Rope tensioner kit, stainless steel, rope length 100 m ZB0060: Rope tensioner kit, stainless steel, rope length 126 m ZB0061: Safety spring, stainless steel, 220 mm ZB0062: Pulley E7015S: Safe AS-i Safety at Work PCB E11295: M12 adapter plug to metric M20, 4 poles E21010: M20 x 1.5 cable gland 15
16 11 Standards The following standards and directives have been applied: Machinery Directive 2006/42/EC Low voltage directive 2006/95/EC EN ISO : 2008 EN ISO 13850: 2008 AS : 2006 IEC / EN : 2004 IEC / EN : A1: 2005 UL 508 The device must be supplied from an electrically isolated source having a secondary UL-listed fuse rated as noted in the following table. Overcurrent protection Wire cross section control circuit Maximum nominal current of the protective Evaluation unit (mm 2 equipment ) ampere 26 (0.13) 1 24 (0.20) 2 22 (0.32) 3 20 (0.52) 5 18 (0.82) 7 16 (1.3) 10 Hints for AS1755 Information with regard to AS : Clause ) Perpendicular force to operate the switches midway between eyebolt Supports: Check <70N. rope deflection <300mm 2) Axial force - direct along rope axis: <230N (Typical 125N). Typical parameters for successful operation of a system is less than 70N pulling force with less than 150mm deflection of rope between eyebolt supports. This can normally be achieved with rope switches set to the mid position between the green arrows in the viewing window. If required, depending upon the necessary checks along the active length of coverage, the tension can be increased further beyond the mid position to ensure a tripping pulling force of less than 70N. 16
17 12 Approvals / certificates EC declaration of conformity TÜV Rheinland (pending) UL (culus) AS
Prewired position switches FA series
2 Prewired position switches FA series Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 51 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable lever 41 45
Position switches FP series
A Position switches FP series Selection diagram 0 08 8 9 0 0 0 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fiber glass rod gasket sphere sphere adjustable lever safety adjustable lever
Operating instructions Capacitive sensor KIA (M30) / / 2010
Operating instructions Capacitive sensor KIA (M30) UK 704182 / 03 07 / 2010 Contents 1 Preliminary note 3 2 Safety instructions 3 3 Functions and features 3 3.1 Application examples 4 4 Installation 4
Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection
0102 Model Number Features Direct mounting on standard actuators Compact and stable housing Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up to SIL2 acc. to IEC 61508 Accessories
E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)
Pressure Sensor (Stainless Steel Diaphragm) CSM DS_E_3_1 Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications Incorporates double diaphragms consisting of SUS316L stainless
PPS PORTABLE POWER SUPPLY
PPS User Manual Rev 1-2015 ENG MASTER PPS PORTABLE POWER SUPPLY Disclaimer About ActSafe Safety messages and warnings Product safety System description Pre-use inspection and connection General safety
Technical Data. General specifications. Rated operating distance s n 5 mm
0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching
DSL, DSH: Specially designed pressure limiter
Product data sheet 11.1 23.770 DSL, DSH: Specially designed pressure limiter How energy efficiency is improved Control and monitoring according to needs and with no auxiliary energy. Features Switching
Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.
2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies We reserve the right to make technical changes without notice. Technische Änderungen vorbehalten. Sous réserve de modifications techniques.
Safety Rope Pull Switches SR and SRM
Safety Rope Pull Switches SR and SRM Safety Rope Pull Switches For more safety on the production line Whether on the conveyor belt or on the machine when maximum safety is required, BERNSTEIN rope pull
Operating Instructions
Operating Instructions Light-metal Ex d enclosures / flameproof enclosure > 8265/0 Empty enclosure > 8265/4 Control panel, integrated in Ex e enclosure > 8265/5 Control panel Table of Contents 1 Table
Technical Data. Dimensions
00 Model Number Features mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,
Tightness controls TC 1 3 and TC 4
Tightness controls TC 1 3 and TC 4 Test of both safety valves Short test period thanks to logical decision-making in the program sequence Adjustable test period which can be adapted to different systems
Contents. Operating instructions. Pressure switch, heavy-duty version Model PSM-520
Operating instructions Contents EN Pressure switch, heavy-duty version Model PSM-520 1. General information 2. Design and function 3. Safety 4. Transport, packaging and storage 5. Commissioning, operation
Pressure Switches Application Guideline
Pressure Switches Application Guideline Product Overview The Fema Pressure Switch product portfolio provides devices suitable for many applications. The portfolio contains Special functions and equipment
Zelio Relays RSL Slim Interface Plug-In Relays
Zelio Relays RSL Slim Interface Plug-In Relays Catalog 8501CT0901 2009 Class 8501 CONTENTS Description............................................. Page Introduction.................................................3
Automatic Valve Proving Control
ISO 9001 Automatic Valve Proving Control 7 696 LDU11 UL recognized FM approved Features Performs leak test of the gas shut-off valves before start-up and/or immediately after burner shut-down No inlet
Technical Data. Dimensions
0102 Model Number Features 2 mm flush Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 2 mm Installation flush Output
INSTRUCTION MANUAL Pressure Relief Device LPT
INSTRUCTION MANUAL Pressure Relief Device LPT 5COV475800 LPT REV00 CONTENT: 1 SAFETY 1.1 Safety instructions 2 1.2 Specified applications 2 1.3 Safety notes on the equipment operation 2 2 PRESSURE RELIEF
TECHNICAL MANUAL DHR60 LED. Den Haan Rotterdam MED96/98/EC
TECHNICAL MANUAL DHR60 LED MED96/98/EC SINCE 1922 Den Haan Rotterdam DISCLAIMER Despite constant care and attention DHR puts in its manuals it is still possible that information in this manual is incomplete
E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information
Liquid Level EK-L CSM_EK-L_DS_E 3 Liquid Level That Is Unaffected by the Color of the or Liquid Mount to bypass pipes. Fit a wide range of pipe diameters: 8 to mm or to mm Built-in Amplifiers to save space.
SPECIFICATIONS ATTENTION
VPS 504 S06 Installation Manual - P/N 80122 - Ed. 01/09 VPS 504 S06 and S05 Valve Proving System Installation Instructions VPS 1 6 Gases Natural gas, air and other inert gases. NOT suitable for butane
Pressure switch Type BCP
Data sheet Pressure switch Type BCP The BCP type is a series of dedicated switches for safety and monitoring of steam and hot water boilers. The BCP incorporates a single-pole changeover microswitch where
PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100
MPS-1100 User Manual Mega Pool Saver Ltd PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100 For further up to date instructions on how to install Mega Pool Saver MPS 1100, please
Manual Power relay SR853
Manual Power relay SR853 Rev. 0 SR853 manual page2 Safety Guidelines for explosion proof devices Application and Standards This instruction manual applies to explosion protected control systems of protection
JUMO dtrans p30 Pressure Transmitter
609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +49 661 600-0 Fax: +49 661 600-607 Phone: +44 179 6 55 Data Sheet 40466 Page 1/6 JUMO dtrans p0 Pressure Transmitter General application Pressure
Differential pressure switch MP 54, MP 55 and MP 55A
Data sheet Differential pressure switch MP 54, MP 55 and MP 55A MP 54 and MP 55 oil differential pressure switches are used as safety switches to protect refrigeration compressors against low lubricating
GM-7000 Series CE Approved Gas Control Valve
Installation Instructions GM-7000 Issue Date November 9, 2012 GM-7000 Series CE Approved Gas Control Valve Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing
Types and approvals. Page 1/6. Data Sheet
Page 1/6 Panel-mounting Thermostats EM Series as: Protection temperature monitor STW (STB) Protection temperature limiter STB tested to DIN 3440 and Pressure Equipment Directive 97/23/EC Brief description
Available models Devices Color White sealing bellows Black sealing bellows NDT SW NDT GB NDT RT NDT GN NDT WS NDT BL NDT GR
Pushbuttons Left: type series N with sealing bellows, color white (standard). Right: type series N with sealing bellows, color black. Protective collar against unintentional actuation: refer to page 58
PRODUCT SPECIFICATION
MINI-FIT SR. SERIES 1.0 SCOPE This specification covers the 10.00 mm / (.394 in.) centerline tin and gold plated connector series, single and dual row versions in wire to wire and wire to printed circuit
Operating instructions Pressure sensor. PN422x / / 2013
Operating instructions Pressure sensor PN422x 80002606 / 00 11 / 2013 Contents 1 Preliminary note...3 1.1 ymbols used...3 2 afety instructions...3 3 Functions and features...3 4 Function...5 4.1 witching
Electromechanical pressure switches
Presentation Electromechanical pressure switches OsiSense XM For power circuits, type XMP Presentation Pressure switches type XMP are switches for power circuits (direct switching), with an adjustable
Dual Solenoid Gas Valve Installation
Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing or servicing FLYNN Gas Products. Carefully follow all instructions in this bulletin and all instructions
250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO
250C-IG COMPRESSOR KIT 12V PART NO. 25050 250C-IG COMPRESSOR KIT 24V PART NO. 25058 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual
250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO
250C-IG COMPRESSOR KIT 12V PART NO. 25050 250C-IG COMPRESSOR KIT 24V PART NO. 25058 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual
Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS
Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. Supplied with an electric input signal of 4 to 20
Installation, operating and maintenance Instructions for Seemag bypass level indicator
Issue: S Date: 05-09-14 Type G35 General information The Seetru bypass magnetic level indicator, abbreviate SEEMAG, serves to show the filling level of fluids in tanks, basins, tubes etc. The Seemag operates
Pressure Measurement Single-range transmitters for general applications
Siemens A 207 Overview Application The SITRANS P Compact pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials
HBLT-A1 LIQUID LEVEL SENSOR
Instruction manual HBLT-A1 LIQUID LEVEL SENSOR for measuring liquid level in refrigerant vessels Instruction manual HBLT - A1 - Liquid level Transmitter (HBLT-A1-008-UK) 1 / 16 Contents Safety instructions...
Meta-MEC Manual Motor Starters
www.lsis.biz Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 45 mm 70 mm 63AF 100AF 3 LS Meta-MEC Manual Motor Starters deliver more
IMPORTANT SAFETY INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock: - Do not disassemble. Do not attempt repairs or modifications. Refer to qualified service agencies for all service and repairs.
Technical Data. General specifications Switching element function Rated operating distance s n 5 mm
00 Model Number Features 5 mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,
Bourdon tube pressure gauge for diaphragm seals
Bourdon tube pressure gauge for diaphragm seals and switch function, Type series BR42.. Features Bourdon tube pressure gauge for diaphragm seal and switch function Nominal range -1 3 bar to -1 15 bar,
G92 Series BASOTROL Automatic Pilot Gas Valve
Installation Instructions Issue Date September 17, 2008 G92 Series BASOTROL Automatic Pilot Gas Valve Installation IMPORTANT: Only qualified personnel should install or service BASO Gas Products. These
DSB, DSF: Pressure monitors and pressure switches
roduct data sheet 23.760 DSB, DSF: ressure monitors and pressure switches How energy efficiency is improved Control and monitoring according to needs and with no auxiliary energy Features For regulating
Pressure switches and thermostats, type KPS
Description KPS units are pressure-controlled switches. The position of the contacts depends on the pressure in the inlet connection and the set scale value. In this series, special attention has been
Electrical operating instructions
Electrical operating instructions GB Door Control Panel TS 980 only for SE 6.70 FU (Design and functions subject to change) 51171178 / 10.2002 OPERATING AND INSTALLATION INSTRUCTIONS PAGE SAFETY DIRECTIONS...4
Electrical operating instructions
en Electrical operating instructions Door control panel TS 980 (Design and functions subject to change) 51171150 - b 07.2007 OPERATING AND INSTALLATION INSTRUCTIONS PAGE SAFETY DIRECTIONS...4 ENCLOSURE
Proportional pressure regulators VPPE
Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/
GENERAL APPLICATION NOTES
GENERAL APPLICATION NOTES There are common considerations when using our connectors. Additional considerations may apply based on the particular connector being used, the application, and conditions in
Pressure switches for air and water CS
Data sheet Pressure switches for air and water CS CS pressure switches have a built-in pressure operated, three-pole switch. The contact position of which depends on the pressure in the connector and the
Relative pressure switch type 521
Relative pressure switch type 521 Pressure range 0... 2.5 600 bar The compact type 521 pressure switch is based upon the Huba Control developed thick film technology where the pressure measuring cell is
Safety Manual OPTISWITCH series relay (DPDT)
Safety Manual OPTISWITCH series 5000 - relay (DPDT) 1 Content Content 1 Functional safety 1.1 In general................................ 3 1.2 Planning................................. 5 1.3 Adjustment
INSTALLATION GUIDE FIRST STEPS MOUNTING OF THE SENSOR HANDLING THE WIRE ROPE
INSTALLATION GUIDE Draw wire sensors series SX0, SX80, SX0 For further information please see the data sheet at www.waycon.biz/products/draw-wire-sensors FIRST STEPS WayCon Positionsmesstechnik GmbH would
120 Series Explosion-Proof Pressure and Differential Pressure Switches
120 Series Explosion-Proof Pressure and Differential Pressure Switches Types J120, J120K, H121, H121K, H122, H122K SIL2 Certified UNITED ELECTRIC CONTROLS Installation and Maintenance Instructions Please
IECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx CML 14.0034X Issue No:
Part I -Installation Tools Needed Screwdriver/Adjustable Wrench to 1-1/2 MOUNTING
120 Series Explosion-Proof Pressure and Differential Pressure Switches Types J120, J120K, H121, H121K, H122, H122K UNITED ELECTRIC CONTROLS Installation and Maintenance Instructions Please read all instructional
Rosemount 2130 Level Switch
Rosemount 2 Level Switch Vibrating Fork Reference Manual Reference Manual Title Page Rosemount 2 Level Switch Vibrating Fork NOTICE Read this manual before working with the product. For personal and system
Pressure switch and Thermostat KPS
Data sheet Pressure switch and Thermostat KPS The KPS Series consists of a series of pressure and temperature controlled switches. In this series, special attention has been given to meeting demands for
trafo_011_a_1_cat Bar or cable-through Multiple applications per: - cables: Ø 17 to Ø 100 mm, - bars: 20 x 5 mm to 2 x 125 x 10 mm.
Current transformers Measurement devices trafo_012_a_1_cat trafo_077_b_1_cat trafo_010_a_1_cat trafo_008_a_1_cat trafo_011_a_1_cat Functions SOCOMEC current transformers deliver to the secondary a standard
EX-RECESSED CEILING LIGHT FITTINGS
EX-RECESSED CEILING LIGHT FITTINGS RLF/RLF-INOX 250 18-58 W / RLF/RLF-INOX 250... N 18-36 W Metallic design for Zone 1 and Zone 21 The RLF... explosion-protected recessed ceiling light fittings with electronic
Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC
Mechatronic pressure measurement Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC WIKA data sheet PV 35.41 Process Compact Series Applications Differential pressure monitoring
Digital Inflation Equipment 89XDA 89XDD 89XDB 89XDE.
Digital Inflation Equipment 89XDA 89XDD 89XDB 89XDE S P E C I F I C A T I O N S I N S T A L L A T I O N O P E R A T I O N S E R V I C E Please read this manual before carrying out any installation or service
Media-Isolated Mag Plus Probe Low Pressure-ISO Kit
Manual No: 577013-975 Revision: B Media-Isolated Mag Plus Probe Low Pressure-ISO Kit Installation Guide Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but
BGA158, BGA171 and BGA110 Series Shutoff Gas Valve
Installation Instructions BGA Series Issue Date October 3, 2017 BGA158, BGA171 and BGA110 Series Shutoff Gas Valve Applications The BGA Series shutoff gas valve is an electrically operated gas valve that
Type Operating Instructions. Bedienungsanleitung Manuel d utilisation
2/2- and 3/2-way cartridge solenoid valve 2/2- und 3/2-Wege-Cartridge-Magnetventil Électrovanne cartridge à 2/2 ou 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation We reserve the
UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions
Document Number: XE-ATA5PM-R1A UBEC 1AT AUTO TANK Fill System 08899155 Installation, Operation, & Setup Instructions Rev170906-EB-FRC PHYSICAL: 1302 WEST BEARDSLEY AVE ELKHART, IN 46514 WWW.ELKHARTBRASS.COM
AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST
AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST OIL-LESS TYPE IMPORTANT: PLEASE READ CAREFULLY BEFORE STARTING OPERATIONS. THE CONTENTS ARE FOR GENERAL INFORMATION OF ALL THE SIMILAR MODELS. Record
Air Sensor. FCS Ex. Manual. AQ Elteknik AB
Air Sensor FCS Ex Manual AQ Elteknik AB Air Sensor Model FCS Ex Manual version 2.0 Oct 2010 AQ Elteknik AB AQ Elteknik AB Air Sensor Manual 2 Table of contents 1. Manufacturer information... 4 Manufacture
Pressure Switch for gas and air
Switch for gas and air GAO-A4 GMH-A4 GML-A4 UL Listed UL 353 File # MH 16628 CSA Certified CSA C22.2 No. LR 53222 Certification file # 201527 FM Approved Class 3510, 3530 File # J.I. 1Y919.AF Commonwealth
Gas Pressure Switch for DMV safety shutoff valves
Gas Switch for DMV safety shutoff valves GAO-A GMH-A GML-A UL Listed UL 353 File # MH 1668 CSA Certified CSA C. No. LR 53 File # 0157 FM Approved Class 3510, 3530 File # J.I. 1Y9A9.AF Commonwealth of Massachusetts
Supplementary Operator s Manual 42/24-14 EN Rev. 3
Advance Optima Continuous Gas Analyzers AO2000 Series with Uras26, Magnos206, Caldos25, Caldos27 Designed per Category 3G for Measurement of Flammable Gases ( Safety Concept ) and Non-flammable Gases Supplementary
Pressure Independent Control Valve (PICV) Fig DN15-32
Installation and Operating Instructions Pressure Independent Control Valve (PICV) Fig. 1932 - DN15-32 GENERAL NOTES The Hattersley Fig.1932 PICV; can be used in variable volume heating and chilled water
PRESSURE, VACUUM AND TEMPERATURE
5 4 S er i es 5 4 Se r i e s PRESSURE, VACUUM AND TEMPERATURE features Compact Size Wide Selection of Adjustable Ranges: Pressure: 30 Hg Vac to 6000 psi (-1 to 413,7 bar) Temperature: -130 to 650 F (-90
KGW - ISOTHERM. Operating Instructions. Level controlling device for liquid nitrogen LEVEL CONTROL LN2
KGW - ISOTHERM Germany 76185 Karlsruhe Gablonzer Straße 6 Tel. 0049 / 721 / 95897-0 Fax. 0049 / 721 / 95897-77 email:info@kgw-isotherm.de Internet: www.kgw-isotherm.de Operating Instructions Level controlling
Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25
Self-operated Pressure Regulators Differential Pressure Regulators (opening) Type 42-20 Type 42-25 Type 42-20 Differential Pressure Regulator Type 42-25 Differential Pressure Regulator Mounting and Operating
1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition
Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.
Mounting and Operating Instructions EB 2172 EN. Series 43 Temperature Regulators. Type 43-5 and Type Type Type 43-6
Series 43 Temperature Regulators Type 43-5 and Type 43-7 Type 43-6 Type 43-6 Type 43-7 with flanged valve body, DN 32 to 50 Type 43-5 Type 43-7 with welding ends Mounting and Operating Instructions EB
PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING
PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING Please Note: Ranges above 500mbar are designed and manufactured in accordance with sound engineering
For ELECTRIC ANCHOR WINCH Models: T Pontoon 35 T sw Salt Water Series Coastal 35
INSTALLATION AND OPERATING INSTRUCTIONS ANCHOR WINCHES For ELECTRIC ANCHOR WINCH Models: T10109-35 Pontoon 35 T10102-35sw Salt Water Series Coastal 35 If you have any questions or difficulty installing
BGA158 Series CE Approved Class A Shutoff Gas Valve
Installation Instructions BGA158 Issue Date August 24, 2011 BGA158 Series CE Approved Class A Shutoff Gas Valve Applications The BGA158 Series shutoff gas valve is an electrically operated gas valve that
ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05
Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 100 mbar up to 0... 400 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing
Proportional Throttle Cartridges, Size 16
Proportional Throttle Cartridges, Size 16 Q max = 5 l/min, p max = 5 bar, Q N max = 14 l/min at p 1 bar Two-Stage, with Seat-Valve Shut-Off 1 Description Normally closed Seat-valve shut-off from 1 Compact
Type 130 and HL10 'Safeguard High Limit Control' Installation and Maintenance Instructions
0730042/6 IM-P073-08 CH Issue 6 Type 130 and HL10 'Safeguard High Limit Control' Installation and Maintenance Instructions 1. General safety information 2. General product information 3. Installation 4.
Pressure Measurement Single-range transmitters for general applications
Siemens AG 07 Overview Function U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/ Equipotential bonding Diaphragm The pressure
Gas Pressure Switch for DMV safety shutoff valves
Gas Switch for DMV safety shutoff valves GAO-A GMH-A GML-A UL Listed UL 353 File # MH 1668 CSA Certified CSA C. No. LR 53 File # 0157 FM Approved Class 3510, 3530 File # J.I. 1Y9A9.AF Commonwealth of Massachusetts
Inverse Proportional Pressure-Relief Cart., Size 2 4
Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 5 bar Direct acting, electrically operated 1 Description inverse proportional pressure-relief valves are direct acting screw-in cartridges
Rosemount 2120 Full-featured
Rosemount 220 Full-featured Vibrating Fork Liquid Level Switch Reference Manual Reference Manual Title Page Rosemount 220 Full-featured Vibrating Fork Liquid Level Switch Read this manual before working
New Thinking in Control Reliability
Doug Nix, A.Sc.T. Compliance InSight Consulting Inc. New Thinking in Control Reliability Or Your Next Big Headache www.machinerysafety101.com (519) 729-5704 Control Reliability Burning Questions from the
GA24 Technical Datasheet
GA24 Technical Datasheet Variable-area flowmeter Sturdy construction for several applications Local indication without auxiliary power Replaceable mounting parts KROHNE CONTENTS GA24 1 Product features
MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE
SIT Group SIT -3- SIGMA MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE 9.955. Subject to change without notice Application Domestic gas appliances: central heating boilers, combi boilers, instantaneous
VLT 2000 Series. How to size your VLT
Selection of frequency converter Usually the size of frequency converter is chosen on the basis of the shaft output, as this may be the only value known. However, if the data are known for both the application,
Product Catalogue MINICOMB. Switches for Pressure and Vacuum
Product Catalogue MINICOMB Switches for Pressure and Vacuum PL ATEX 2 DEFINITION OF PRESSURE A force applied uniformly over a certain area is called pressure: p = F / A (pressure = force / area) Pressure
MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.
Installation Instructions manual MUELLER table of contents PAGE A-20806 A-20807 Adjustable General Information 2 Technical Data 3 Dimensions 4 Installation 5-6 Parts 7 Maintenance 8 Vertical Indicator
Digital Inflation Equipment 89XDZ 89XDX. Please read this manual before carrying out any installation or service procedures.
Digital Inflation Equipment 89XDX 89XDZ S P E C I F I C A T I O N S I N S T A L L A T I O N O P E R A T I O N S E R V I C E Please read this manual before carrying out any installation or service procedures.
Hand lever valves VHER
Hand lever valves VHER Hand lever valves VHER Key features Powerful Flexible Practical -M- Flow 170 3800 l/min 4/3-way valve mid-position closed mid-position exhausted mid-position pressurised Connections:
SAPCON. User Manual. Capacitance Continuous Level Indicator. . Introduction. . General Description. . Principle of Operation. .
User Manual Capacitance Continuous Level Indicator Comprehensive User s Manual. Introduction. General Description. Principle of Operation. Specifications. Connection Diagrams. Quick Calibration Chart.
METEOR LSR0640 UNDERWATER POOL LIGHT. Operating Instructions
METEOR LSR0640 UNDERWATER POOL LIGHT Operating Instructions CONTENTS Preface...3 Features...3 Precautions...3 Components and Connectors...4 Installation...5 Controls...7 Appearance...9 Technical Specifications...9
Components for Pull Rope Systems. Leaflet No. Kiepe 680
Components for Pull Rope Systems Leaflet No. Kiepe 680 APPLICATION Pull ropes are used as actuators for operation of pull rope emergency stop switches along coveyor belts. The Kiepe pull ropes and accessories