The Industrial Accident Resulted from the Failure of Bolt

Size: px
Start display at page:

Download "The Industrial Accident Resulted from the Failure of Bolt"

Transcription

1 The Industrial Accident Resulted from the Failure of Bolt Hyun Wook YEO 1, Jae Min LEE 2 and Sang Won CHOI 1, * 1 Occupational Safety and Health Research Institute, Korea Occupational Safety and Health Agency, Ulsan, South Korea. 2 Department of Mechanical Design Engineering, Andong National University, Andong, South Korea. Abstract This study was to perform an investigation of the cause of industrial accident, the cause of failure of anchor bolt to collapse a steel frame structure on a construction site for two workers on the steel frame structure to fall down and die. Through the investigation of the accident site, the process of accident and the situation of accident site were evaluated. The finite element analysis on the steel frame structure was used for an analysis, and the occurrence process of accident and the circumstances of accident site when the accident occurred were applied as analytic conditions. According to the investigation of accident site and the finite element analysis, it is evaluated that the asymmetric load by the weight of steel frame structure and the external load under insufficient fixture and support of steel frame structure led the failure of anchor bolt to cause the collapse of steel frame structure. Also, it is confirmed that two anchor bolts at the back side to receive the tensile stress among anchor bolts installed at the pillar on the opposite of external force were broken in the first place to lead the collapse of steel frame structure by the feature of anchor bolt failure evaluated through the Von Mises stress distribution. Figure 1: Feature of steel frame structure before accident Keywords: Industrial accident; Bolt; Failure; Finite element analysis; Investigation of accident; INTRODUCTION In the industrial site, when bolts to be used to fasten construction materials or machinery parts are failed due to overload or fatigue, a serious industrial accident to cause a severe damage may occur frequently. However, while there are several studies about an analysis of engineering cause of bolt failure in the industrial site [1, 2, 3], the analysis of cause of bolt failure with respect to the investigation of cause of industrial accident has not been studied much. In this study, the investigation was performed on the cause of anchor bolt failure to cause the serious industrial accident letting two workers on a steel frame structure to fall and die. The feature of steel frame structure at which the accident occurred is shown in Figure 1 and Figure 2. The root diameter of bolt was 20mm, and the nominal ultimate tensile strength was 444N/mm 2. For reference, the investigation of accident site and the testimony by witness confirmed that the steel frame structure was collapsed during the main assembly (fastening of upper bolt connection) from the temporary assembly. Figure 2: Feature of steel frame structure fell after accident METHODS Through the site investigation of industrial accident, the process of accident and the situation of accident site were evaluated, and the collapsed steel frame structure was modeled to be analyzed by using the finite element analysis including the process of disaster and the situation of accident site as analytic conditions. For concrete determination of a possibility of anchor bolt failure, EN :, Eurocode 3: Design of steel structures. Part 1-8: Design of joints was referred [4]. RESULTS Anchor bolt failure process Steel frame structure modeling To predict the process of steel frame structure falling, the steel frame structure modeled into the same dimension and the same weight (9921.9kg) using the density and the external 7426

2 load (5000N of load each by two wires connected to the steel frame structure) during the accident were applied. The steel frame structure was modeled as the 3-D beam, the complete fixture at both ends of lower part of steel frame structure was applied as the boundary condition, and the modulus of elasticity of N/m 2, Poisson ratio of 0.285, and density of 7850kg/m 3 provided by the manufacturer of steel were applied on the steel frame structure. two anchor bolts 5 and 6 (refer to Figure 6) located on the opposite side of falling direction of steel frame structure out of four anchor bolts on the right fixture receive the tensile stress by asymmetric load from the weight of steel frame structure [6], it was evaluated that they were damaged in the first place among eight anchor bolts. Review of the feature of anchor bolt failure Figure 5: Feature of left anchor bolts failed Figure 3: Modeling of steel frame structure (Load: weight of steel frame structure and external load, Boundary: location of anchor bolts) Figure 6: Feature of right anchor bolts failed Figure 4: Von Mises stress distribution (Load: weight of steel frame structure and external load, Boundary: location of anchor bolts) As a result of Von Mises stress distribution review [5], on the right fixture at the bottom section of steel frame structure (refer to Figure 4), the maximum stress was formed, and since The characteristics of anchor bolt failure evaluated through the site investigation of accident are the followings: Among four anchor bolts on the right side, the threads of anchor bolt 5 and 6 located at the back side (opposite of falling direction) were crushed by tensile stress [6], but they were not broken. Since this section receives the strongest tensile load by the asymmetric load of the weight of steel frame structure and by the pulling load of two wire ropes connected to the steel frame structure among anchor bolts, this section shall be deformed or failed in the first place. 7427

3 Except for 5 and 6, other anchor bolts were failed or pulled out by instantaneous impact. Comparing with the surface of failure of other anchor bolts, the surface of failure of anchor bolt 2 at the back side among four anchor bolts at the left side was tilted to left. Estimation of anchor bolt failure The process of anchor bolt failure estimated based on the feature of anchor bolt failure evaluated through the Von Mises stress distribution [5] by the finite element analysis and the site investigation of accident is the following: The asymmetric load by the weight of steel frame structure and the external load (pulling load by a wire rope) crushed the screw threads of anchor bolt 5 and 6 at the back of right side for the steel frame structure to be away from anchor bolt 5 and 6 Instantaneous failure of anchor bolt 7 and 8 at the front of right side Anchor bolt 2 was failed while it was tilted to the left side by the collapsing steel frame structure -Center of compression axis [refer to EN :2005 Figure 6-15] (a) EN :2005 Figure 6-15 c) Review of anchor bolt safety To analyze the failure of anchor bolt, the process of accident and the situation of accident site were concerned to perform the finite element analysis for two cases, and the EN :, Eurocode 3: Design of steel structures. Part 1-8: Design of joints [4] was referred to review the safety of anchor bolt. Case1. Support of the weight of steel frame structure only by anchor bolts without another support To confirm whether the asymmetric load by the weight of steel frame structure may be supported only with anchor bolts without another support, the density was applied on the steel frame structure modeled with 3-D Beam to apply the weight of steel frame structure, and as the boundary condition, the both ends of bottom of steel frame structure were completely fixed to perform the review of anchor bolt safety. (b) Dimension of end-plate installed anchor Figure 8: Center of compression axis of anchor bolt -Review of anchor bolt safety F t,ed = F t,ed,m + F t,ed,n F t,ed,m = (M Ed h)/(n v h r 2 ) F t,ed,n = N Ed /n t F t,rd = (K 2 f μb A s )/(γ M2 ) (1) (2) (3) (4) Figure 7: Von Mises stress distribution (Load: weight of steel frame structure, Boundary: location of anchor bolts) Review of anchor bolt safety [4] Where F t,ed,m = The tension force from bending moment for one bolt from bolt-row1 F t,ed,n = The axial force for one bolt from bolt-row1 M Ed = The bending moment h = The vertical distance from bolt-row1 to the center of rotation axis (h = 23.8mm) n v = The number of vertical bolt-rows (n v = 2) 7428

4 h r 2 = The sum of the squares of the vertical distances between bolt-row r and the center of compression axis N Ed = The axial force n t = The number of bolts (n t = 4) F t,rd = The design tensile resistance per bolt K 2 = 0.9 [refer to EN :2005 Table 3.4] f μb = The nominal ultimate tensile strength of the bolt (f μb = 444N/mm 2 ) A s = The tensile stress area of the bolt (A s = mm 2 ) γ M2 = Partial safety factor for resistance of bolts (γ M2 = 1.25) [refer to EN :2005 Table 2.1] Table 1: Review of anchor bolt safety (Load: weight of steel frame structure, Boundary: Location of anchor bolts) M Ed N Ed F t,ed,m F t,ed,n F t,ed F t,rd F t,rd/f t,ed (N mm) (N) (N) (N) (N) (N) For M Ed and N Ed,, the values at the location of anchor bolts under higher stress in Figure 7 were applied. Since the comparison value (F t,rd/f t,ed) between the design tensile resistance (F t,rd) and the tensile force (F t,ed) by bending moment and axial force is , anchor bolts may not hold the load by themselves. Case2. Support of external load/weight of steel frame structure/weight of two workers by braces/pipe support/anchor bolts To review the safety of anchor bolt supposing two braces and four pipe supports which were installed at the site when the accident occurred hold the steel frame structure without their own failure or deformation, the analysis was performed by applying external load (5,000N of pulling load each by two wire ropes connected on the steel frame structure), the weight of steel frame structure, and the weight of two workers as the load on the steel frame structure modeled in 3-D beam, and as the boundary condition, two braces and four pipe support and the both ends of bottom of steel frame structure were completely fixed. Figure 10: Von Mises stress distribution (Load: external load, weight of steel frame structure, and weight of workers, Table 2: Review of anchor bolt safety (Load: external load, weight of steel frame structure, and weight of workers, M Ed N Ed F t,ed,m F t,ed,n F t,ed F t,rd F t,rd/f t,ed (N mm) (N) (N) (N) (N) (N) For M Ed and N Ed,, the values at the location of anchor bolts under higher stress in Figure 7 were applied. Under the assumption that two braces and four pipe supports hold the steel frame structure without their own deformation or failure, since the comparison value (F t,rd/f t,ed) between the design tensile resistance (F t,rd) and the tensile force (F t,ed) by bending moment and axial force is , if braces and pipe supports are not failed or deformed, the anchor bolst may not fail. Figure 9: Modeling of steel frame structure (Load: external load, weight of steel frame structure, and weight of workers, CONCLUSION Even though anchor bolts without other supports can t hold the asymmetric load only by the weight of steel frame structure, if pipe supports and braces support the steel frame structure without their own deformation or failure, the anchor bolt may not be failed during the accident according to the results of analysis of the failure of anchor bolt. Therefore, it is evaluated that the asymmetric load by the weight of steel frame structure and the external load led the failure of pipe supports and braces temporarily installed at the accident site for the steel frame structure to collapse. Also, it is identified that the two anchor bolts at the back side to receive the tensile stress among four anchor bolts installed at the right fixture to be opposite of the external load were broken in the first place 7429

5 to lead the collapse of steel frame structure by the feature of anchor bolt failure evaluated through the Von Mises stress distribution. CONFLICTS OF INTEREST No potential conflicts of interest relevant to this article were reported REFERENCES [1] M.T. Milan, D. Spinelli, W.W. Bose Filho, M.F.V. Montezuma, V. Tita, Failure analysis of a SAE 4340 steel locking bolt, Engineering Failure Analysis 11 (2004) [2] Z. Zhenqian,, T. Zhiling, Y. Chun, L. Shuangping, Failure analysis of vessel propeller bolts under fastening stress and cathode protection environment, Engineering failure analysis 57 (2015) [3] W. Tizani, N.A. Rahman, T. Pitrakkos, Fatigue life of an anchored blind-bolt loaded in tension, Journal of Constructional Steel Research 93 (2014) 1-8. [4] EN :, Eurocode 3: Design of steel structures. Part 1-8: Design of joints, European Committee for Standardization (CEN), Brussels, Belgium, [5] W.F. Hosford, A Generalized Isotropic Yield Criterion, J. Appl. Mech 39(2) (1972), [6] W.C. Young, R.G. Budynas, Roark s Formulas for Stress and Strain, Seventh ed. the McGraw-Hill Companies, Inc., New York, 2002, pp

Design and Optimization of Weld Neck Flange for Pressure Vessel

Design and Optimization of Weld Neck Flange for Pressure Vessel V th International Symposium on Fusion of Science & Technology, New Delhi, India, January 18-22, 2016 ID: 2016-ISFT-430 Design and Optimization of Weld Neck Flange for Pressure Vessel Vinod Kumar 1, Vivek

More information

Engineering Practice on Ice Propeller Strength Assessment Based on IACS Polar Ice Rule URI3

Engineering Practice on Ice Propeller Strength Assessment Based on IACS Polar Ice Rule URI3 10th International Symposium on Practical Design of Ships and Other Floating Structures Houston, Texas, United States of America 2007 American Bureau of Shipping Engineering Practice on Ice Propeller Strength

More information

STRESS ANALYSIS OF RATCHET PAWL DESIGN IN HOIST USING FINITE ELEMENT ANALYSIS

STRESS ANALYSIS OF RATCHET PAWL DESIGN IN HOIST USING FINITE ELEMENT ANALYSIS STRESS ANALYSIS OF RATCHET PAWL DESIGN IN HOIST USING FINITE ELEMENT ANALYSIS 1* Hariyali M.Patil, 2 P.A.Chandak 1 (Department of MechanicalEngineering, DMIETR/ Nagpur, India) 2( Department of MechanicalEngineering,

More information

Elastic-Plastic Finite Element Analysis for Zhongwei--guiyang Natural Gas Pipeline Endangered by Collapse

Elastic-Plastic Finite Element Analysis for Zhongwei--guiyang Natural Gas Pipeline Endangered by Collapse Abstract Elastic-Plastic Finite Element Analysis for Zhongwei--guiyang Natural Gas Pipeline Endangered by Collapse Gengxin Wu,Peng Zhang,Zhixiang Li,Zunhai Ke,Guizhi Li,Anmin Jiang 2 School of Civil Engineering

More information

FEA ANALYSIS OF PRESSURE VESSEL WITHDIFFERENT TYPE OF END CONNECTIONS

FEA ANALYSIS OF PRESSURE VESSEL WITHDIFFERENT TYPE OF END CONNECTIONS FEA ANALYSIS OF PRESSURE VESSEL WITHDIFFERENT TYPE OF END CONNECTIONS Deval Nitin Bhinde 1 and Rajanarsimha S. 2 1 MTech CAD-CAM & Robotics, 2 Facculty, Department of Mechanical Engineering K.J. Somaiya

More information

Stress evaluation of a bicycle crank arm connection using BEM

Stress evaluation of a bicycle crank arm connection using BEM Stress evaluation of a bicycle crank arm connection using BEM C. J. Hoff, R. E. Dippery & 3. Knapp Department of Mechanical Engineering Kettering University, USA Abstract An interesting problem encountered

More information

TECHNICAL MANUAL. COPRA Anchoring Coupler. For Smart Bolted Connections

TECHNICAL MANUAL. COPRA Anchoring Coupler. For Smart Bolted Connections TECHNICAL MANUAL Anchoring Coupler For Smart Bolted Connections Version: PEIKKO GROUP 03/2017 Anchoring Coupler For bolted connections Multi-purpose anchoring system for all bolted connections Simplifi

More information

COMPFIRE CCFT-FP_550_55_ September 2010 Fin Plate Connection to Circular Concrete-Filled Tube Test Result

COMPFIRE CCFT-FP_550_55_ September 2010 Fin Plate Connection to Circular Concrete-Filled Tube Test Result Reaction Frame Macalloy Bars Camera 3 Support Beam α Oven Bar Camera 2 Link Bar Camera 1 Tested Connection Jack Bar Electrical Furnace Reaction Frame Load Jack v2_5 April 2011 1 Oven Bar Link Bar View

More information

Vessels subject to External Pressure

Vessels subject to External Pressure Basic principles of compressive force Vessels subject to External Pressure Before After The result of just air pressure! Presented by: Ray Delaforce Basic principles of compressive force Consider For a

More information

SHEAR PERFORMANCE OF RC FOOTING BEAMS BY CAP-TIE SYSTEM USING WELDED STIRRUPS

SHEAR PERFORMANCE OF RC FOOTING BEAMS BY CAP-TIE SYSTEM USING WELDED STIRRUPS The 7th International Conference of Asian Concrete Federation SUSTAINABLE CONCRETE FOR NOW AND THE FUTURE 3 Oct 2 Nov, 216, Hanoi, Vietnam www.acf216.vn SHEAR PERFORMANCE OF RC FOOTING BEAMS BY CAP-TIE

More information

An Innovative Solution for Water Bottling Using PET

An Innovative Solution for Water Bottling Using PET An Innovative Solution for Water Bottling Using PET A. Castellano, P. Foti, A. Fraddosio, S. Marzano, M.D. Piccioni, D. Scardigno* DICAR Politecnico di Bari, Italy *Via Orabona 4, 70125 Bari, Italy, scardigno@imedado.poliba.it

More information

Stress Analysis of The West -East gas pipeline with Defects Under Thermal Load

Stress Analysis of The West -East gas pipeline with Defects Under Thermal Load Stress Analysis of The West -East gas pipeline with Defects Under Thermal Load Abstract Xu Lei School of Petroleum Engineering, Yangtze University, Wuhan 430000, China 13071247220@163.com Natural gas is

More information

Fatigue Life Evaluation of Cross Tubes of Helicopter Skid Landing Gear System

Fatigue Life Evaluation of Cross Tubes of Helicopter Skid Landing Gear System IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 04, 2015 ISSN (online): 2321-0613 Fatigue Life Evaluation of Cross Tubes of Helicopter Skid Landing Gear System Madhu S

More information

Davorin Matanović DRILLING LINE (ROPE) AND BLOCKS

Davorin Matanović DRILLING LINE (ROPE) AND BLOCKS Davorin Matanović DRILLING LINE (ROPE) AND BLOCKS DRILLING LINE (ROPE) AND BLOCKS The term drilling line pertain to the wire rope made from steel wires. It is spooled onto the drum of the draw works hoist,

More information

6995(Print), ISSN (Online) Volume 4, Issue 1, January- April (2013), IAEME TECHNOLOGY (IJDMT)

6995(Print), ISSN (Online) Volume 4, Issue 1, January- April (2013), IAEME TECHNOLOGY (IJDMT) International INTERNATIONAL Journal of Design JOURNAL and Manufacturing OF DESIGN Technology AND MANUFACTURING (IJDMT), ISSN 0976 TECHNOLOGY (IJDMT) ISSN 0976 6995 (Print) ISSN 0976 7002 (Online) Volume

More information

CARES Technical Approval Report TA1-B & C 5059

CARES Technical Approval Report TA1-B & C 5059 CARES Technical Approval Report TA1-B & C 5059 Issue 2 DEXTRA Griptec Anchors Assessment of the Griptec Anchors Product and Quality System for Production 5059 Product DEXTRA Griptec Anchors for reinforcing

More information

Analysis of Shear Lag in Steel Angle Connectors

Analysis of Shear Lag in Steel Angle Connectors University of New Hampshire University of New Hampshire Scholars' Repository Honors Theses and Capstones Student Scholarship Spring 2013 Analysis of Shear Lag in Steel Angle Connectors Benjamin Sawyer

More information

CHAPTER IV FINITE ELEMENT ANALYSIS OF THE KNEE JOINT WITHOUT A MEDICAL IMPLANT

CHAPTER IV FINITE ELEMENT ANALYSIS OF THE KNEE JOINT WITHOUT A MEDICAL IMPLANT 39 CHAPTER IV FINITE ELEMENT ANALYSIS OF THE KNEE JOINT WITHOUT A MEDICAL IMPLANT 4.1 Modeling in Biomechanics The human body, apart of all its other functions is a mechanical mechanism and a structure,

More information

Design and Finite Element Analysis of Fabricated Panama chock with 225T capacity

Design and Finite Element Analysis of Fabricated Panama chock with 225T capacity LOWER HULL TOP DEC K EL. 3 1 ' - 2 " AB L [ 9 5 0 0 ] ( E) AIR DUC T ( INB D) ( E) B HD 1 4 m m `AH' ( E) PL. 1 2 m m `AH' ( E) L 1 5 0 x9 0 x1 2 m m `AH' - DO- - DO- SMIT BRACKET PANAMA CHOCK International

More information

TEST PROTOCOL VERIFICATION OF THE BEHAVIOUR OF A MECHANICAL COMPRESSION COUPLING DURING SETTLEMENT

TEST PROTOCOL VERIFICATION OF THE BEHAVIOUR OF A MECHANICAL COMPRESSION COUPLING DURING SETTLEMENT TEST PROTOCOL VERIFICATION OF THE BEHAVIOUR OF A MECHANICAL COMPRESSION COUPLING DURING SETTLEMENT Nova Siria factory, Roletto, April 6, 2011 Introduction Mechanical steel compression couplings (CC) are

More information

Investigation of Stresses in Ring Stiffened Circular Cylinder

Investigation of Stresses in Ring Stiffened Circular Cylinder International Journal of Engineering and Technical Research (IJETR) ISSN: 2321-869, Volume-2, Issue-9, September 214 Investigation of Stresses in Ring Stiffened Circular Cylinder Neetesh N. Thakre, Dr.

More information

fischer Epoxy Mortar FIS EB The basic epoxy mortar for applications in concrete

fischer Epoxy Mortar FIS EB The basic epoxy mortar for applications in concrete fischer Epoxy Mortar FIS EB The basic epoxy mortar for applications in concrete For standard applications in concrete and rebar connections. Advantages at a glance Epoxy mortar for applications in concrete

More information

Premium PowerPoint Presentation. Rigging Review

Premium PowerPoint Presentation. Rigging Review Premium PowerPoint Presentation Rigging Review Chapter 1 Hoisting Safety Review: What about the CG Symmetrical vs. Asymmetrical Balanced and Unbalanced Lifting Lug Hooks Angle Deformation Safety Gates

More information

Proceedings of the ASME th International Conference on Ocean, Offshore and Arctic Engineering OMAE2011

Proceedings of the ASME th International Conference on Ocean, Offshore and Arctic Engineering OMAE2011 Proceedings of the ASME 2011 30th International Conference on Ocean, Offshore and Arctic Engineering OMAE2011 June 19-24, 2011, Rotterdam, The Netherlands Proceedings of the ASME 2011 30th International

More information

Wedge couplers are used for making a temporary connection between two tubes:

Wedge couplers are used for making a temporary connection between two tubes: Wedge couplers are used for making a temporary connection between two tubes: Right angle coupler: connecting two tube in a right angle Swivel coupler: connecting two tubes in any angle Sleeve coupler:

More information

Plastic non-symmetric bifurcation buckling of circular cylinders under uniform external hydrostatic pressure

Plastic non-symmetric bifurcation buckling of circular cylinders under uniform external hydrostatic pressure icccbe 2010 Nottingham University Press Proceedings of the International Conference on Computing in Civil and Building Engineering W Tizani (Editor) Plastic non-symmetric bifurcation buckling of circular

More information

DESIGN OF AN UNDERWATER TOWFISH USING DESIGN BY RULE AND DESIGN BY ANALYSIS

DESIGN OF AN UNDERWATER TOWFISH USING DESIGN BY RULE AND DESIGN BY ANALYSIS Proceedings of the ASME 204 Pressure Vessels & Piping Conference PVP204 July 20-24, 204, Anaheim, California, USA PVP204-2822 DESIGN OF AN UNDERWATER TOWFISH USING DESIGN B RULE AND DESIGN B ANALSIS Martin

More information

Introduction Introduction

Introduction Introduction Introduction Maritime International is a leading manufacturer of marine bollards and cleats worldwide. Our range of bollards and cleats is unsurpassed by any other manufacturer or supplier. Maritime can

More information

Use equation for the cylindrical section and equation or for the ends.

Use equation for the cylindrical section and equation or for the ends. Solution 13.1 See section 13.3.4, equations 13.7 to 13.18 Solution 13.2 Use equation 13.34. (a) rigid constant C = 0.43 (b) free to rotate, C = 0.56 Solution 13.3 See section 13.5.1 Use equation 13.39

More information

STUDY OF UNDERWATER THRUSTER (UT) FRONT COVER OF MSI300 AUTONOMOUS UNDERWATER VEHICLE (AUV) USING FINITE ELEMENT ANALYSIS (FEA)

STUDY OF UNDERWATER THRUSTER (UT) FRONT COVER OF MSI300 AUTONOMOUS UNDERWATER VEHICLE (AUV) USING FINITE ELEMENT ANALYSIS (FEA) STUDY OF UNDERWATER THRUSTER (UT) FRONT COVER OF MSI300 AUTONOMOUS UNDERWATER VEHICLE (AUV) USING FINITE ELEMENT ANALYSIS (FEA) M. Sabri 1, 2, T. Ahmad 1, M. F. M. A. Majid 1 and A. B. Muhamad Husaini

More information

Tribology in Industry. Research Regarding Drilling Masts Reliability under the Combined Action of the Wind and the Hook Load

Tribology in Industry. Research Regarding Drilling Masts Reliability under the Combined Action of the Wind and the Hook Load RESEARCH Vol. 37, No. 1 (2015) 29-33 Tribology in Industry www.tribology.fink.rs Research Regarding Drilling Masts Reliability under the Combined Action of the Wind and the Hook Load I. Popa a, L.S. Stanciu

More information

Tresca s or Mises Yield Condition in Pressure Vessel Design

Tresca s or Mises Yield Condition in Pressure Vessel Design Tresca s or Mises Yield Condition in Pressure Vessel Design Franz Rauscher Institute for Pressure Vessels and Plant Technology Vienna University of Technology Austria Why using Tresca s yield condition

More information

The Adequacy of Pushover Analysis to Evaluate Vulnerability of Masonry Infilled Steel Frames Subjected to Bi-Directional Earthquake Loading

The Adequacy of Pushover Analysis to Evaluate Vulnerability of Masonry Infilled Steel Frames Subjected to Bi-Directional Earthquake Loading The Adequacy of Pushover Analysis to Evaluate Vulnerability of Masonry Infilled Steel Frames Subjected to Bi-Directional Earthquake Loading B.Beheshti Aval & M. Mohammadzadeh K.N.Toosi University of Technology,

More information

DECLARATION OF PERFORMANCE

DECLARATION OF PERFORMANCE ROCKWOOL B.V. / ROCKPANEL Group Konstruktieweg 2 NL-6045 JD Roermond, Netherlands www.rockpanel.com DECLARATION OF PERFORMANCE No. 0764-CPR-0276 DK english - vs01 1. Unique identification code of the product-type:

More information

A Study on the Eccentric Loading of K Node of Steel Tube Tower

A Study on the Eccentric Loading of K Node of Steel Tube Tower International Conference on Advances in Energy, Environment and Chemical Engineering (AEECE-2015) A Study on the Eccentric Loading of K Node of Steel Tube Tower LIU Haifeng a Wang Fei b Han Junke b Hu

More information

Bottom End-Closure Design Optimization of DOT-39 Non-Refillable Refrigerant Cylinders

Bottom End-Closure Design Optimization of DOT-39 Non-Refillable Refrigerant Cylinders Y. Kisioglu a) Department of Mechanical Education, Kocaeli University, Izmit, Kocaeli, 41100, Turkey J. R. Brevick Industrial and Systems Engineering, The Ohio State University, Columbus, Ohio G. L. Kinzel

More information

TECHNICAL CIRCULAR. Circular No: S-P 32/13 Revision: 1 Page: 1 of 7 Date:

TECHNICAL CIRCULAR. Circular No: S-P 32/13 Revision: 1 Page: 1 of 7 Date: Circular No: S-P 32/13 Revision: 1 Page: 1 of 7 Date:22.05.2014 Related Requirement: UR S27 (Rev.6 June 2013) Subject: Retroactive Application for Strength Requirements for Fore Deck Fittings and Equipment

More information

MECHANICAL ASPECTS OF SUBMARINE CABLE ARMOUR

MECHANICAL ASPECTS OF SUBMARINE CABLE ARMOUR MECHANICAL ASPECTS OF SUBMARINE CABLE ARMOUR Ernesto Zaccone ARMORING OF SUBMARINE CABLES Submarine cables must be robust Mechanical aspects are at least as important as the electrical o nes Must withstand

More information

FEA case Study: Rubber expansion joint for piping systems

FEA case Study: Rubber expansion joint for piping systems FEA case Study: Rubber expansion joint for piping systems Introduction The FEA Toolbox of Taniq makes it possible to simulate the behavior of a pipe expansion joint accurately under several load cases.

More information

Structural Design and Analysis of the New Mobile Refuge Chamber

Structural Design and Analysis of the New Mobile Refuge Chamber Key Engineering Materials Online: 2013-09-10 ISSN: 1662-9795, Vol. 584, pp 175-178 doi:10.4028/www.scientific.net/kem.584.175 2014 Trans Tech Publications, Switzerland Structural Design and Analysis of

More information

STRESS ANALYSIS OF BELL CRANK LEVER

STRESS ANALYSIS OF BELL CRANK LEVER STRESS ANALYSIS OF BELL CRANK LEVER Mr. M. M. Dange 1, Prof. S. R. Zaveri 2 1 Department of Mechanical Engineering, R.C.E.R.T., R.T.M.N.U, Chandrapur, (India) 2 Department of Mechanical Engineering, R.C.E.R.T.,

More information

FLEXIBLE AND RELIABLE ANCHORING

FLEXIBLE AND RELIABLE ANCHORING Spiral rope anchor and FLEX Head FLEXIBLE AND RELIABLE ANCHORING 1 THE SMARTER ANCHOR FLEXES. The flexibility of the whole system is crucial for both rockfall barriers and other protection systems. Why?

More information

Load Ring bolted > VWBG < in pink

Load Ring bolted > VWBG < in pink RUD-Art.-Nr.: 8503693-EN / 03.014 Load Ring bolted > VWBG < in pink EN Safety instructions This safety instruction/declaration has to be kept on file for the whole lifetime of the product. Translation

More information

fischer Epoxy Mortar FIS EB

fischer Epoxy Mortar FIS EB fischer Epoxy Mortar FIS EB The basic epoxy mortar for applications in concrete ETA-15/0771 ETAG 001-5 Post-installed rebar connection (TR2 fischer Epoxy Mortar FIS EB: For standard applications in concrete

More information

Rudder Investigation. By Harish M

Rudder Investigation. By Harish M Rudder Investigation By Harish M Where and on What? Series of RO RO Vessels designed and constructed by Flensberger Schiffbau Gesselshaft GmbH. Rudders independently manufactured by Macor Neptun GmbH.

More information

Self-drilling hollow anchor bolts and accessories

Self-drilling hollow anchor bolts and accessories Self-drilling hollow anchor bolts and accessories Application During the constructions of underground works, it is very common to encounter soft rock, fractured zone and large deformation due to high ground

More information

Design and Analysis of Pressure Safety Release Valve by using Finite Element Analysis

Design and Analysis of Pressure Safety Release Valve by using Finite Element Analysis Design and Analysis of Pressure Safety Release Valve by using Finite Element Analysis Mr.V.D.Rathod* 1, Prof.G.A.Kadam* 2, Mr.V. G. Patil* 3 * 1 M.E. Design (Pursuing), SKN Sinhgad Institute of Technology&

More information

The Powerful Sealing Calculation

The Powerful Sealing Calculation KLINGER expert 6.0 The Powerful Sealing Calculation The KLINGER expert 6.0 gasket design program is a versatile software to assist users in the selection of non-metallic gasket materials. www.klinger.co.at

More information

Experimental Method to Analyse Limit Load in Pressure Vessel

Experimental Method to Analyse Limit Load in Pressure Vessel International OPEN ACCESS Journal Of Modern Engineering Research (IJMER) Dilip M. Patel 1, Dr. Bimlesh Kumar 2 1 Mechanical Department D.N.Patel COE, Shahada 2 Mechanical Department COE, Faizpur Abstract:

More information

International Journal of Modern Trends in Engineering and Research e-issn No.: , Date: 2-4 July, 2015

International Journal of Modern Trends in Engineering and Research   e-issn No.: , Date: 2-4 July, 2015 International Journal of Modern Trends in Engineering and Research www.ijmter.com e-issn No.:2349-9745, Date: 2-4 July, 2015 Fillet Radius Optimization of Bell Crank Lever Swapneel R. Zende 1, Mohammed

More information

EEF. Fatigue Testing Unit PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION. Engineering and Technical Teaching Equipment

EEF. Fatigue Testing Unit PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION. Engineering and Technical Teaching Equipment Engineering and Technical Teaching Equipment Fatigue Testing Unit EEF PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION ISO 9001: Quality Management (for Design, Manufacturing, Commercialization and After-sales

More information

The cost-efficient fixing for flexible use in non-cracked concrete VERSIONS. zinc-plated steel stainless steel hot-dip galvanised steel

The cost-efficient fixing for flexible use in non-cracked concrete VERSIONS. zinc-plated steel stainless steel hot-dip galvanised steel The cost-efficient fixing for flexible use in non-cracked concrete VERSIONS APPROVALS zinc-plated steel stainless steel hot-dip galvanised steel BUILDING MATERIALS Approved for: Concrete C20/25 to C50/60,

More information

Effects of Changes of Spokes in the Operation of a Rimmed Flywheel

Effects of Changes of Spokes in the Operation of a Rimmed Flywheel Effects of Changes of Spokes in the Operation of a Rimmed Flywheel M M 1, Ramachandra N K 2, Shruthi RP 3 1 Asst. Professor, Dept. of Mechanical Engineering, T.JOHN Institute of Technology,B lore-83 2

More information

High-Energy Ship Collision with Jacket Legs

High-Energy Ship Collision with Jacket Legs High-Energy Ship Collision with Jacket Legs Jørgen Amdahl Department of Marine Structures, NTNU, Trondheim, Norway Atle Johansen MARINTEK, Trondheim, Norway ABSTRACT Risk analysis of planned jacket installations

More information

Floor Mount Socket. T: +44 (0) F: +44 (0)

Floor Mount Socket. T: +44 (0) F: +44 (0) G-Davit : Floor Mount Socket USER INSTRUCTION MANUAL A davit socket for installation bolted to a high strength flooring material. Suitable for both fall arrest use and lifting. EN795 Class B, PPE Anchor

More information

Abstract. 1 Introduction

Abstract. 1 Introduction Buoyancy and strength of existing bulk carriers in flooded conditions J. Jankowski, M. Bogdaniuk, T. Dobrosielski Polski Rejestr Statkow, Gdansk, Poland Email: tk@prs.gda.pl Abstract Bulk carriers have

More information

API HPHT 6BX Flange Design, Verification & Capabilities: Example use of Methodology

API HPHT 6BX Flange Design, Verification & Capabilities: Example use of Methodology API HPHT 6BX Flange Design, Verification & Capabilities: Example use of Methodology January 22 nd, 2018 Summary 1. Determine the suitability of the existing BX gaskets for 20K 2. Use Robert Eichenberg

More information

Vertical Uplift Capacity of a Group of Equally Spaced Helical Screw Anchors in Sand

Vertical Uplift Capacity of a Group of Equally Spaced Helical Screw Anchors in Sand SECM/15/080 Vertical Uplift Capacity of a Group of Equally Spaced Helical Screw Anchors in Sand S. Mukherjee 1* and Dr. S. Mittal 2 1 Amity University, Noida, India 2 Indian Institute of Technology, Roorkee,

More information

Hatch cover securing and tightness

Hatch cover securing and tightness (1986) (Rev 1 1996) (Corr.1 June 2000) (Rev.2 July 2005) (Corr.1 Oct 2005) Hatch cover securing and tightness 1. Application 1.1 The following recommendations apply to steel hatch covers that are fitted

More information

Design Guide MSW from M20 to M70. Original version of the design guide

Design Guide MSW from M20 to M70. Original version of the design guide Page 1 of 11 Original version of the design guide For Series Components Spieth locknuts (precision locknuts) MSW 20.28 MSW 20.40 MSW 25.28 MSW 25.40 MSW 30.28 MSW 30.44 MSW 35.28 MSW 35.44 MSW 40.28 MSW

More information

Wind action on small sky observatory ScopeDome

Wind action on small sky observatory ScopeDome Wind action on small sky observatory ScopeDome A.Flaga a, G. Bosak a, Ł. Flaga b, G. Kimbar a, M. Florek a a Wind Engineering Laboratory, Cracow University of Technology, Cracow, Poland, LIWPK@windlab.pl

More information

Technical Manual. Stand 05/2011

Technical Manual. Stand 05/2011 MULTI-MONTI Technical Manual Stan5/2011 Technical Manual HECO-MULTI-MONTI Contents Instructions for fixing P. 3 Chapter 1 : Admissible loads in as well as P. 4 anchor-characteristics for MMS-6 to MMS-16

More information

STRESS ANALYSIS OF BICYCLE PADDLE AND OPTIMIZED BY FINITE ELEMENT METHOD. S. Abeygunasekara 1, T. M. M. Amarasekara 2

STRESS ANALYSIS OF BICYCLE PADDLE AND OPTIMIZED BY FINITE ELEMENT METHOD. S. Abeygunasekara 1, T. M. M. Amarasekara 2 - 96 - STRESS ANALYSIS OF BICYCLE PADDLE AND OPTIMIZED BY FINITE ELEMENT METHOD S. Abeygunasekara 1, T. M. M. Amarasekara 2 1 Faculty of Engineering & Technology, Colombo International Nautical Engineering

More information

SPOKES & NIPPLES FOR BICYCLE 2017

SPOKES & NIPPLES FOR BICYCLE 2017 SPOKES & NIPPLES FOR BICYCLE 2017 HISTORY AND PRESENT Based in Lomagna, in the heart of Lombardy, Alpina Raggi S.p.A. was founded in 1926 and focusses its activity on the production of spokes and nipples.

More information

DAMAGE TO STORAGE TANKS CAUSED BY THE 2011 TOHOKU EARTHQUAKE AND TSUNAMI AND PROPOSAL FOR STRUCTURAL ASSESSMENT METHOD FOR CYLINDRICAL STORAGE TANKS

DAMAGE TO STORAGE TANKS CAUSED BY THE 2011 TOHOKU EARTHQUAKE AND TSUNAMI AND PROPOSAL FOR STRUCTURAL ASSESSMENT METHOD FOR CYLINDRICAL STORAGE TANKS DAMAGE TO STORAGE TANKS CAUSED BY THE 2011 TOHOKU EARTHQUAKE AND TSUNAMI AND PROPOSAL FOR STRUCTURAL ASSESSMENT METHOD FOR CYLINDRICAL STORAGE TANKS Takashi Ibata Isho Nakachi Dr. Kazuo Ishida Junichi

More information

A parametric study of metal-to-metal contact flanges with optimised. geometry for safe stress and no-leak conditions

A parametric study of metal-to-metal contact flanges with optimised. geometry for safe stress and no-leak conditions A parametric study of metal-to-metal contact flanges with optimised geometry for safe stress and no-leak conditions M. Abid *, D. H. Nash a * Faculty of Mechanical Engineering, Ghulam Ishaq Khan Institute

More information

Also suitable for: Concrete C12/15. For fixing of: Steel constructions Railings Consoles Ladders Wooden constructions Cable trays Machines Staircases

Also suitable for: Concrete C12/15. For fixing of: Steel constructions Railings Consoles Ladders Wooden constructions Cable trays Machines Staircases 28 Highbond anchor FHB II Flexible installation and highest loads in the cracked tensile zone. OVERVIEW FHB II-A S (standard), zinc plated steel FHB II-A L (performance optimised), zinc-plated steel Resin

More information

RMANCE ROCKPANEL. System 1. inorganic finish. english. - vs01. Konstruktieweg. Tel. Fax. Notified. Body: 1. Unique. 4. System as set.

RMANCE ROCKPANEL. System 1. inorganic finish. english. - vs01. Konstruktieweg. Tel. Fax. Notified. Body: 1. Unique. 4. System as set. ROCKWOOL B.V. / ROCKPANEL Groupp Konstruktieweg 2 NL-6045 JD Roermond Netherlands www.rockpanel.com DECLARATION OF PERFOR RMANCE No. 0764-CPR-0237 DK english - vs01 1. Unique identificationn code of the

More information

Fatigue Analysis of English-Willow Cricket Bat

Fatigue Analysis of English-Willow Cricket Bat Fatigue Analysis of English-Willow Cricket Bat Mr. Rajshekhar Chimmat 1, Mr. Shreenidhi Kulkarni 2 1M.Tech. Scholar, Dept. of Mechanical Engineering, KLS Gogte Institute of Technology, Belagavi, Karnataka,

More information

DESIGN AND ANALYSIS OF A COLD GAS PROPULSION SYSTEM FOR STABILIZATION

DESIGN AND ANALYSIS OF A COLD GAS PROPULSION SYSTEM FOR STABILIZATION DESIGN AND ANALYSIS OF A COLD GAS PROPULSION SYSTEM FOR STABILIZATION AND MANEUVERABILITY OF A HIGH ALTITUDE RESEARCH BALLOON COLLEGE OF ENGINEERING & APPLIED SCIENCES SENIOR DESIGN THESIS GREGORY A. NEFF

More information

sarens

sarens sarens group www.sarens.com Sarens Climbing Tower SCT The SARENS CLIMBING TOWER is designed for lifting heavy loads in the construction, petrochemical and offshore industries. The system is suited to using

More information

DEVELOPMENT OF SAFE VERTICAL AXIS WIND TURBINE

DEVELOPMENT OF SAFE VERTICAL AXIS WIND TURBINE The Seventh Asia-Pacific Conference on Wind Engineering, November 8-12, 29, Taipei, Taiwan DEVELOPMENT OF SAFE VERTICAL AXIS WIND TURBINE FOR OVER SPEED ROTATION Minoru Noda 1, Fumiaki Nagao 2 and Akira

More information

TZ WEDGE ANCHOR FOR CRACKED AND UNCRACKED CONCRETE

TZ WEDGE ANCHOR FOR CRACKED AND UNCRACKED CONCRETE www.ucanfast.com TECHNICAL MANUAL SECTION 2.2 PAGE 1 / 10 ä DESCRIPTION UCAN TZ torque controlled mechanical expansion wedge anchors have a Category 1 classification. They are used to resist static, wind

More information

CONVECTION SECTION FAILURE ANALYSIS AND FITNESS-FOR-SERVICE ASSESSMENT

CONVECTION SECTION FAILURE ANALYSIS AND FITNESS-FOR-SERVICE ASSESSMENT ASSET INTEGRITY INTELLIGENCE CONVECTION SECTION FAILURE ANALYSIS AND FITNESS-FOR-SERVICE ASSESSMENT JAMES R. WIDRIG, Manager Advanced Engineering at Quest Integrity Group VOLUME 23, ISSUE 6 NOVEMBER DECEMBER

More information

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073 Operating instructions Safety Rope Emergency Stop Switches UK ZB0052 / ZB0053 ZB0072 / ZB0073 7390878 / 02 03 / 2011 Contents 1 Safety instructions...3 2 Installation / set-up...4 2.1 Applications...4

More information

SET OF EUROLEAGUE BACKSTOP UNITS (Reference PK120)

SET OF EUROLEAGUE BACKSTOP UNITS (Reference PK120) SET OF EUROLEAGUE BACKSTOP UNITS (Reference PK120) DESCRIPTION The EUROLEAGUE backstop unit is mainly designed for multi-sports pavilions and installations where the highest-level basketball competitions

More information

Design and Safety Document for the Vacuum Windows of the NPDGamma Liquid Hydrogen Target at SNS

Design and Safety Document for the Vacuum Windows of the NPDGamma Liquid Hydrogen Target at SNS Design and Safety Document for the Vacuum Windows of the NPDGamma Liquid Hydrogen Target at SNS Prepared: Checked: Approved: H. Nann W. Fox M. Snow The NPDGamma experiment is going to run at BL13 at SNS

More information

1 General. 1.1 Introduction

1 General. 1.1 Introduction 1 General 1.1 Introduction The contents of this book will focus on the anatomy of the aeroplane and the various systems that enable it to operate both on the ground and in the air. Flight controls Landing

More information

Operations and Instruction Manual Might Swivel Model # Concrete and Steel Anchorage Connector ANSI Z ,000 lbs / 44kn

Operations and Instruction Manual Might Swivel Model # Concrete and Steel Anchorage Connector ANSI Z ,000 lbs / 44kn Operations and Instruction Manual Might Swivel Model # 00238 Concrete and Steel Anchorage Connector ANSI Z359.1 10,000 lbs / 44kn Description: Zinc plated forged heat treated steel, Special design gives

More information

IMO ANCHORING, MOORING AND TOWING EQUIPMENT. Submitted by the Republic of Korea

IMO ANCHORING, MOORING AND TOWING EQUIPMENT. Submitted by the Republic of Korea INTERNATIONAL MARITIME ORGANIZATION E IMO SUB-COMMITTEE ON SHIP DESIGN AND EQUIPMENT 48th session Agenda item 6 DE 48/6/1 17 November 2004 Original: ENGLISH ANCHORING, MOORING AND TOWING EQUIPMENT Shipboard

More information

Study and Analysis of Pin of Knuckle Joint in Train

Study and Analysis of Pin of Knuckle Joint in Train Study and Analysis of Pin of Knuckle Joint in Train 1 Ravindra S. Dharpure, 2 Prof D. M. Mate 1 M. Tech., PCE, 2 PCE.Nagpur Abstract - The current paper presents the problem of the failure of the knuckle

More information

BARRIER OFFSET 0" A 6" 6" A 12" 12" A 26" A 26" 3A OR 4A L OR S * ** L OR S L OR S

BARRIER OFFSET 0 A 6 6 A 12 12 A 26 A 26 3A OR 4A L OR S * ** L OR S L OR S ACCEPTABLE (TCB) TYPES AND ANCHORING DETAILS BASED ON UNDERLYING SURFACE TYPE AND BARRIER OFFSET FROM DROP-OFF BARRIER OFFSET UNDERLYING SURFACE 0" A 6" 6" A 12" 12" A 26" A 26" TCB TYPE DETAIL TCB TYPE

More information

Impact Test Equipment Ltd & User Guide. User Guide

Impact Test Equipment Ltd   &   User Guide. User Guide SL Impact Test Equipment Ltd www.impact-test.co.uk & www.impact-test.com User Guide User Guide Impact Test Equipment Ltd. Building 21 Stevenston Ind. Est. Stevenston Ayrshire KA20 3LR T: 01294 602626 F:

More information

THIN CYLINDERS AND SHELLS

THIN CYLINDERS AND SHELLS CHAPTR 9 THIN CYLINDRS AND SHLLS Summary The stresses set up in the walls of a thin cylinder owing to an internal pressure p are: circumferential or hmp stress ah = longitudinal or axial stress al = -

More information

LIFTING PIN VDI3366. Item code: B Use and maintenance manual complete of EC conformity declaration. San Maurizio C.

LIFTING PIN VDI3366. Item code: B Use and maintenance manual complete of EC conformity declaration.   San Maurizio C. Via Quarantelli 8-10077 - San Maurizio C.se - Italy T +39 011 996 46 11 - F +39 011 996 46 46 C.F./P.IVA 07677130010 info@omcr.it - www.omcr.it Use and maintenance manual complete of EC conformity declaration.

More information

Second Generation Bicycle Charging Station. Engineering Analysis

Second Generation Bicycle Charging Station. Engineering Analysis Second Generation Bicycle Charging Station By Jonathan Jerome, Michael Klinefelter, Connor Kroneberger, Kori Molever, and Robert Rosenberg Team 22B Engineering Analysis Document Submitted towards partial

More information

Mechanical Anchoring Systems HDA Undercut Anchor Product description. HDA-P Undercut Anchor Pre-Set Type

Mechanical Anchoring Systems HDA Undercut Anchor Product description. HDA-P Undercut Anchor Pre-Set Type Mechanical Anchoring Systems 3.3 3.3.1 HDA Undercut Anchor 3.3.1.1 Product description The Hilti HDA undercut anchor is a heavy-duty mechanical anchor with carbide-tipped undercut segments used to perform

More information

P-04 Stainless Steel Corrugated Hoses and Metal Bellows Expansion Joints

P-04 Stainless Steel Corrugated Hoses and Metal Bellows Expansion Joints Guideline No.P-04 (201510) P-04 Stainless Steel Corrugated Hoses and Metal Bellows Expansion Joints Issued date: 20 th October 2015 China Classification Society Foreword This Guideline is a part of CCS

More information

Benefits. caused by overloading Quick. tester. ons. Applicati HAP 1.15 HAP safety. shackle. After activation safety shackle.

Benefits. caused by overloading Quick. tester. ons. Applicati HAP 1.15 HAP safety. shackle. After activation safety shackle. HAP 1.15 Hoist Anchor Plate Benefits No limitation in load direction, hookk (shackle) can rotate and swivel, symmetric design of base plate withh 4 anchors Design fits application requirements of dynamic

More information

Tightening Evaluation of New 400A Size Metal Gasket

Tightening Evaluation of New 400A Size Metal Gasket Proceedings of the 8th International Conference on Innovation & Management 307 Tightening Evaluation of New 400A Size Metal Gasket Moch. Agus Choiron 1, Shigeyuki Haruyama 2, Ken Kaminishi 3 1 Doctoral

More information

EFFECT OF SPOKES STRUCTURES ON CHARACTERISTICS PERFORMANCE OF NON-PNEUMATIC TIRES. Helwan University, Egypt. Phone: ; Fax:

EFFECT OF SPOKES STRUCTURES ON CHARACTERISTICS PERFORMANCE OF NON-PNEUMATIC TIRES. Helwan University, Egypt. Phone: ; Fax: International Journal of Automotive and Mechanical Engineering (IJAME) ISSN: 2229-8649 (Print); ISSN: 2180-1606 (Online); Volume 11, pp. 2212-2223, January-June 2015 Universiti Malaysia Pahang DOI: http://dx.doi.org/10.15282/ijame.11.2015.4.0185

More information

The Application of ANSYS Contact Analysis in Cable Crane Load Conversion Device

The Application of ANSYS Contact Analysis in Cable Crane Load Conversion Device 2017 2nd International Conference on Mechanical Control and Automation (ICMCA 2017) ISBN: 978-1-60595-460-8 The Application of ANSYS Contact Analysis in Cable Crane Load Conversion Device Yong-shi HU 1,*,

More information

MAE 322 Machine Design Lecture 5 Fatigue - 2. Dr. Hodge Jenkins Mercer University

MAE 322 Machine Design Lecture 5 Fatigue - 2. Dr. Hodge Jenkins Mercer University MAE 322 Machine Design Lecture 5 Fatigue - 2 Dr. Hodge Jenkins Mercer University Returning to Stress-Life Fatigue Modeling Fatigue Stress-Life: S f -N Diagram for steels Stress levels below S e (Endurance

More information

April 22nd to 25th, 2012

April 22nd to 25th, 2012 www.uni-stuttgart.de AWRF Meeting Spring 2012 Atlanta, Georgia April 22nd to 25th, 2012 04/22/12 1 www.uni-stuttgart.de IFT Rope Technology University of Stuttgart 04/22/12 2 www.uni-stuttgart.de IFT was

More information

1. Air is blown through a pipe AB at a rate of 15 litre per minute. The cross-sectional area of broad

1. Air is blown through a pipe AB at a rate of 15 litre per minute. The cross-sectional area of broad Keshaw Classes IIT/JEE Medical Classes 5-A 11028 / 9, WEA, Sat Nagar, Karol Bagh New Delhi-110005 Mob:9910915514,9953150192 Ph:011-45660510 E-mail : keshawclasses@gmail.com Web:www.keshawclasses.com Solids

More information

Content Technical Data R R38 7-8

Content Technical Data R R38 7-8 http://www.maxdrill.com.cn Content Technical Data R25 4 R32 5-6 R38 7-8 R51 9 T76 10 1 GUIDE OF PRODUCT CODE : Bit:25 M R 30 0 42 http://www.maxdrill.com.cn A B C D E F A Connect size 25 32 38 51 76 B

More information

Tutorial on Flange Qualification using CAEPIPE

Tutorial on Flange Qualification using CAEPIPE Tutorial on Flange Qualification using CAEPIPE This document explains the procedure on performing Flange Qualification using CAEPIPE. General Flange joints are essential components in all pressurized systems;

More information

Technical Briefing Note

Technical Briefing Note Technical Briefing Note Subject Date Issued Revision Glossary of Terms 14th Nov 2017 Rev 3 The purpose of this Technical Briefing Note is to provide a glossary of terms commonly used in fall injury prevention

More information

Design of submarine pressure hulls to withstand buckling under external hydrostatic pressure

Design of submarine pressure hulls to withstand buckling under external hydrostatic pressure icccbe 2010 Nottingham University Press Proceedings of the International Conference on Computing in Civil and Building Engineering W Tizani (Editor) Design of submarine pressure hulls to withstand buckling

More information

Presented to the International Technical Rescue Symposium, November Abstract

Presented to the International Technical Rescue Symposium, November Abstract Presented to the International Technical Rescue Symposium, November 21 Presented by: Chuck Weber, PMI Quality Manager Abstract This paper presents the results of 162 individual drop tests performed at

More information