Watts. xppower.com. Input. General. Environmental. Output. EMC & Safety. Output Voltages from 2.5 V to 48 V. Non-standard Outputs Available
|
|
- Verity Hudson
- 5 years ago
- Views:
Transcription
1 -0 Watts AEH Series s from. V to 8 V xppower.com Non-standard s Available Universal Input Single & Multiple Versions 0 C to +60 C Operating Temperature Efficiency up to 80% Non-standard Connectors Available Specification Input Input Input Frequency Input Inrush Earth Leakage Power Factor 90-6 VAC 7-6 Hz 0./0.6 A for AEH, at /0 VAC./0.7 A for AEH, at /0 VAC.9/. A for AEH80, at /0 VAC./.7 A for AEH0, at /0 VAC AEH, & 80: 0 A max at 0 VAC AEH0: 60 A max at 0 VAC cold start <0. ma max at VAC/60 Hz <0.7 ma max at 0 VAC/0 Hz EN class A See tables, non-standard voltages available - contact sales Initial Set Accuracy % Start Up Delay s max Hold Up Time 6 ms min (>0 ms AEH0) Line Regulation See tables Load Regulation See tables Transient Response % max deviation, recovery to within % in ms for a 0% load change Ripple & Noise % pk-pk for outputs. V % pk-pk for all other outputs 0 MHz bandwidth Overvoltage Protection -% Vnom, auto reset Overload Protection only 0-0% of nominal (AEH protected to short circuit) Temperature ±0.0%/ C max Coefficient General Efficiency Up to 80% Isolation 000 V to 00 V to Ground 00 VAC to Ground Switching Frequency 6-80 khz for AEH 67-8 khz for AEH 8 khz typical for AEH80-76 khz for AEH0 MTBF 00 khrs per MIL-HDBK-7F at C GB Environmental Operating Temperature 0 C to +60 C, derate linearly from 00% load at +0 C to 0% load at +60 C Operating Humidity -9% RH, non-condensing Storage Temperature -0 C to +8 C Vibration g on axes EMC & Safety Emissions Harmonic s Flicker ESD Immunity Radiated Immunity EFT/Burst Surge Conducted Immunity Dips & Interruptions Safety Approvals EN0 level B, conducted and radiated EN6000--, Class A EN EN6000--, level Perf Criteria A EN6000--, level Perf Criteria A EN6000--, level Perf Criteria A EN6000--, level Perf Criteria A EN , level Perf Criteria A EN % 0 ms, 60% 00 ms, 00% 000 ms Perf Criteria A, B, B EN6090-, UL6090-, CSA C. No. 90 per cul, CE Mark
2 AEH Total Model Power Nominal () Minimum Maximum Regulation () 8. W. V 0.0 A.0 A 7% AEHUS0.00 W.0 V 0.0 A.0 A % AEHUS0.00 W 7.0 V 0.0 A.70 A % AEHUS07.00 W 0.0 V 0.0 A.0 A % AEHUS0.00 W.0 V 0.0 A. A % AEHUS.00 W.0 V 0.0 A.00 A % AEHUS.00 W 8.0 V 0.0 A 0.8 A % AEHUS8.00 W.0 V 0.0 A 0.6 A % AEHUS.00 W 0.0 V 0.0 A 0.0 A % AEHUS0.00 W 6.0 V 0.0 A 0. A % AEHUS6.00 W 8.0 V 0.0 A 0. A % AEHUS8. Factory-set non-standard outputs available.. Total regulation includes initial set accuracy, line and load regulation. IEC 0 Inlet. (8.0). (6.0).8 (9.0). connector is.mm outer diameter barrel. Inner diameter is.mm with centre positive (+) and outer shell negative (-).. cable length is 7.0 (80).. Optional output connectors available, contact sales office. 6. Weight 0.6 lb (6 g) approx. 7. For UK mains lead order part: UK-MAINS-IEC.
3 AEH (,) (,) (,) Model Max Nom. Min Max Nom. Min Max Nom. Min Max 0 W. V 0.0 A 8.0 A AEHUS0 6 W. V 0.0 A 8.0 A AEHUS0 0 W.0 V 0.0 A 8.0 A AEHUS0 W 7.0 V 0.0 A 6.0 A AEHUS07 W 0.0 V 0.0 A. A AEHUS0 W.0 V 0.0 A.7 A AEHUS W.0 V 0.0 A.9 A AEHUS W 8.0 V 0.0 A. A AEHUS8 8 W.0 V 0.0 A.0 A AEHUS 0 W 0.0 V 0.0 A.7 A AEHUS0 0 W 6.0 V 0.0 A. A AEHUS6 0 W 8.0 V 0.0 A.0 A AEHUS8 W +.0 V 0. A.0 A -.0 V 0. A.0 A AEHUM W +.0 V 0. A.0 A -.0 V 0. A.0 A AEHUM W +.0 V 0. A.0 A +.0 V 0. A.0 A AEHUM W +.0 V 0. A.0 A +.0 V 0. A. A AEHUM6 W +.0 V 0. A.0 A +.0 V 0. A.0 A AEHUM W +.0 V 0. A.0 A -.0 V 0. A.0 A AEHUM7 7 W +. V 0. A.0 A +.0 V 0. A.0 A AEHUM8 0 W +. V 0. A.0 A +.0 V 0. A.0 A AEHUM9 W +.0 V 0. A.0 A +.0 V 0. A.0 A -.0 V 0.0 A 0.8 A AEHUM W +.0 V 0. A.0 A +.0 V 0. A.0 A -.0 V 0.0 A 0.8 A AEHUM W +.0 V 0. A.0 A +.0 V 0. A.0 A -.0 V 0.0 A 0.8 A AEHUM 0 W +. V 0. A. A +.0 V 0. A.0 A -.0 V 0.0 A 0.8 A AEHUM W +. V 0. A.0 A +.0 V 0. A.0 A -.0 V 0.0 A 0.8 A AEHUM W +.0 V 0. A.0 A +.0 V 0. A.0 A -.0 V 0.0 A 0.8 A AEHUM8 W +.0 V 0. A.0 A +.0 V 0. A.0 A -.0 V 0.0 A 0. A AEHUM9. Factory-set non-standard outputs available.. Total regulation includes initial set accuracy, line and load regulation and is typically % for output and % for auxiliaries. DC OUTPUT Pin SINGLE DUAL TRIPLE Shell GND GND GND Common Common Common Common Common Common Common Common.69 (.0).7 (6.0) ±.0 IEC 0-C Inlet.99 (76.0) DC Pin Plug. cable length is 8 (0 mm) approx.. Optional output connectors available, contact sales.. Weight lb (00-00 g) approx. 6. For UK mains lead order part: UK-MAINS-IEC. 7. For mating DIN connector, use standard pin 80 socket.
4 . Factory-set non-standard outputs available.. Total regulation includes initial set accuracy, line and load regulation and is typically % for output and % for auxiliaries. AEH80 (,) (,) (,) Model Max Nom. Min Max Nom. Min Max Nom. Min Max 0 W. V 0.0 A. A AEH80US0 6 W.0 V 0.0 A.0 A AEH80US0 70 W 7.0 V 0.0 A 9.9 A AEH80US07 7 W 0.0 V 0.0 A 7. A AEH80US0 80 W.0 V 0.0 A 6.6 A AEH80US 80 W.0 V 0.0 A. A AEH80US 80 W 8.0 V 0.0 A. A AEH80US8 80 W.0 V 0.0 A. A AEH80US 80 W 0.0 V 0.0 A.6 A AEH80US0 80 W 6.0 V 0.0 A. A AEH80US6 80 W 8.0 V 0.0 A.6 A AEH80US8 60 W +.0 V 0.7 A 7.0 A +.0 V 0. A.0 A AEH80UM 60 W +.0 V. A 7.0 A +.0 V 0.6 A.0 A AEH80UM6 60 W +.0 V. A 7.0 A +.0 V 0. A.0 A AEH80UM 60 W +.0 V. A 7.0 A -.0 V 0. A.0 A AEH80UM9 8 W +. V. A 7.0 A +.0 V 0.6 A.0 A AEH80UM8 6 W +. V 0.7 A 7.0 A +.0 V 0. A.0 A AEH80UM7 6 W +.0 V 0.6 A 6.0 A +.0 V 0. A.0 A -.0 V 0.0 A 0.8 A AEH80UM 6 W +.0 V 0.6 A 6.0 A +.0 V 0. A.0 A -.0 V 0.0 A 0.8 A AEH80UM 6 W +.0 V 0.6 A 6.0 A +.0 V 0. A. A -.0 V 0.0 A 0.8 A AEH80UM 6 W +. V 0.7 A 7.0 A +.0 V 0.6 A.0 A -.0 V 0.0 A 0.8 A AEH80UM 6 W +. V. A 7.0 A +.0 V 0.6 A.0 A -.0 V 0. A 0.8 A AEH80UM7 6 W +.0 V 0.7 A 7.0 A +.0 V 0. A.0 A -.0 V 0.0 A 0.8 A AEH80UM8 6 W +.0 V 0.6 A 6.0 A +.0 V 0. A.0 A -.0 V 0.0 A 0.8 A AEH80UM9 IEC 0-C Inlet.7 (.) 6.6 (67.9) ±.0.09 (78.) DC 8 Pin Plug cable length is 8 (0mm) approx.. Optional output connectors available, contact sales.. Weight lb (00-00 g) approx. 6. For UK mains lead order part: UK-MAINS-IEC, DC Pin Plug DC OUTPUT Pin SINGLES 0, 0 V 07-8 V DUAL TRIPLE Shell GND GND GND GND Common Common Common Common Common Common Common Common 6 Common Common Common 7 8 Common
5 . Factory-set non-standard outputs available.. Total regulation includes initial set accuracy, line and load regulation. AEH0 (,) (,) Model Total Total Max Nom. Min Max Regulation Nom. Min Max Regulation 90 W. V 0.0 A 7. A 7% AEH0PSV W.0 V 0.0 A.0 A 7% AEH0PS0 0 W 7.0 V 0.0 A 8. A 7% AEH0PS07 0 W 9.0 V 0.0 A. A % AEH0PS09 0 W.0 V 0.0 A 0.8 A % AEH0PS 0 W.0 V 0.0 A 8.6 A % AEH0PS 0 W 8.0 V 0.0 A 7. A % AEH0PS8 0 W.0 V 0.0 A. A % AEH0PS 0 W 8.0 V 0.0 A.6 A % AEH0PS8 0 W 6.0 V 0.0 A.6 A % AEH0PS6 0 W 8.0 V 0.0 A.7 A % AEH0PS8 0 W.0 V 0.0 A. A % AEH0PS 90 W +. V.0 A 0.0 A 0% +.0 V 0. A.0 A % AEH0PD0 0 W +.0 V.0 A 0.0 A 7% +.0 V 0. A.0 A % AEH0PD0 0 W +.0 V.0 A 0.0 A 7% +.0 V 0. A.0 A % AEH0PD0 0 W +.0 V.0 A 0.0 A 7% +.0 V 0. A.0 A % AEH0PD0 IEC 0-C Inlet Pin SINGLE DUAL Shell GND GND Common Common Common Common 6 Common Common 7 8 Common 0.8 (.). (9.0) 7.7 (96.0) ±.0.6 (88.0). cable length is 8 (0mm) approx.. Optional output connectors available, contact sales.. Weight.9 lb (860 g) approx. 6. For UK mains lead order part: UK-MAINS-IEC, 6-Jun-
FEATURES AND BENEFITS. Meets UL/EN/IEC , 4Th ed. For EMC*
LPS Medical FEATURES AND BENEFITS Meets UL/EN/IEC60601-1-2, 4Th ed. For EMC* Approved To EN/IEC/UL60601-1, 3rd edition With Isolation Levels Which Satisfy The 2 MOPP Requirements Meets DoE Efficiency Level
More informationSeries AM3T-VZ 3 Watt DC-DC Converter
Click on Series name for product info on aimtec.com Series AM3T-VZ FEATURES: Wide 2:1 Range 24 Pin DIP Package High up to 82% Metal Package Operating Temperature -4 o C to +85 o C / Isolation 15 or 35
More informationJUMO dtrans p30 Pressure Transmitter
609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +49 661 600-0 Fax: +49 661 600-607 Phone: +44 179 6 55 Data Sheet 40466 Page 1/6 JUMO dtrans p0 Pressure Transmitter General application Pressure
More informationDCS Series 1 kw, 1.2 kw, & 3 kw
Established 1981 Advanced Test Equipment Rentals www.atecp.com 800-404-ATEC (2832) DCS Series 1 kw, 1.2 kw, & 3 kw DCS Applications The DCS Family is ideally suited f a wide range of applications requiring
More informationDifferenz-Drucktransmitter Differential pressure transmitter Transmetteur de pression différentielle bar
692 Differenz-Drucktransmitter Differential pressure transmitter Transmetteur de pression différentielle 0 0.1 25 bar E Technical overview The differential pressure transmitter of type series 692 with
More informationQPL... Pressure Switches. Siemens Building Technologies HVAC Products
7 221 Pressure Switches QPL... The pressure switches are used for monitoring gas or air pressures. When the pressure falls below the switching point, the associated electrical circuit will open or switch
More informationMANUAL KPS Pressure Control Valve
TetraTec Instruments GmbH Gewerbestrasse 8 71144 Steinenbronn Deutschland E-Mail: info@tetratec.de Tel.: 07157/5387-0 Fax: 07157/5387-10 MANUAL Pressure Control Valve *** VERSION 1.0 *** Update: 17.11.2006
More informationPicture. Minimum cable bending radius 100 mm [4"] < 400 N [90 lbf] (PE / PUR cables) < 15 N [3.4 lbf] (FEP cables)
Type: for level measurement Order No.: see Table 1 / Page 4 Features Picture Two wire system Piezoresistive measuring element Output signal 4-20 ma Conformity error ±0.5 % FS or Standard DIN measuring
More informationATM.ECO - Analog Pressure Transmitter
Pressure Transmitter ATM.ECO - Analog Pressure Transmitter CUSTOMER BENEFITS Entry level series into precision pressure measurement High measurement accuracy is ensured by sophisticated digital temperature
More informationTest Report #: Date: June 21, 2005
CERTIFICATE #2316.01 Test Report #: 1979-2 Date: June 21, 2005 Issued To: Bill Burks American Power Conversion 85 Rangeway Road North Billerica, MA 01862 USA 978-670-2440 Product Name/Description Uninterruptable
More informationVerdi G-Series Family
Verdi G-Series Family High-Power Pumps for Ti:Sapphire Lasers and Amplifiers Applications such as ultrafast spectroscopy, multiphoton microscopy, terahertz imaging, and Optical Coherence Tomography (OCT)
More informationHUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation
High-precision Humidity Calibrator The role of humidity calibrations that are accurate, reproducible, and documentable is becoming more and more important. ISO quality guidelines and regulations according
More informationATM.1ST. Pressure transmitters CUSTOMER BENEFITS
Pressure transmitters ATM.1ST CUSTOMER BENEFITS High precision pressure sensor over the whole temperature range Electronic compensation Modular sensor structure (any process and electrical connections
More informationTeSys protection components
Presentation, description -pole thermal overload relays TeSys D Presentation TeSys D thermal overload relays are designed to protect a.c. circuits and motors against: b overloads, b phase failure, b excessively
More informationATM.1ST/Ex - High Precision Transmitter
Pressure Transmitter - ATEX / IECEx certified ATM.1ST/Ex - High Precision Transmitter CUSTOMER BENEFITS Certificate: ATEX, IECEx & EAC High measurement accuracy is ensured by sophisticated digital temperature
More informationPIKO IQ 4.2, Plenticore plus 4.2 Rating: 10,0kW 8,5kW 7,0kW 5,5kW 4,2kW Rated voltage: PIKO IQ 8.5, Plenticore plus 8.5
Applicant: Product: Certificate of conformity Generating unit, NS-protection KOSTAL Solar Electric GmbH Hanferstraße 6 79108 Freiburg i. Br. Germany Photovoltaic Inverter with integrated NS-protection
More informationVerdi G-Series. High-Power Pumps for Ti:Sapphire Lasers and Amplifiers FEATURES
Verdi G-Series High-Power Pumps for Ti:Sapphire Lasers and Amplifiers The Verdi G is a high performance CW laser providing up to 20W at 532 nm, ideal for pumping Ti:Sapphire lasers and amplifiers, for
More informationGas density monitor With integrated transmitter Model GDM-100-TI
SF 6 gas solutions Gas density monitor With integrated transmitter Model GDM-100-TI grid Products WIKA data sheet SP 60.05 for further approvals see page 5 Applications Gas density monitoring of closed
More informationEPRB-2 Pressure Transducer
Small size with amplified output Any liquid or gas media compatible with stainless steel Operating temperature up to 150 C (300 F) Variety of pressure ports Available as gage and absolute CE approved DESCRIPTION
More informationModels: BRP391 series; BRP392 series; BRP394 series;
-page 1 of 99-6011997.50 EMC Test report for LED street lighting Models: BRP391 series; BRP392 series; BRP394 series; Shanghai, date of issue: July. 09 th, 2017 Author: Jerremy Cai By order of Philips
More informationKTE6000 / KTU6000 Series OEM pressure transmitters for industrial media
FEATURES 50 mbar to 400 bar, 5 to 6000 psi gage or absolute pressure For many industrial gases and liquids 00, 0545, 05, 6 or 40 ma output Field interchangeable EMC according to EN 66-8 MEDIA COMPATIBILITY
More informationVLT 2000 Series. How to size your VLT
Selection of frequency converter Usually the size of frequency converter is chosen on the basis of the shaft output, as this may be the only value known. However, if the data are known for both the application,
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-20
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater
More informationATM.ECO/IS - Analog Transmitter with Temperature compensation
Pressure Transmitter - FM / FM-C certified ATM.ECO/IS - Analog Transmitter with Temperature compensation CUSTOMER BENEFITS Certificate: FM, FM-C & IECEx & ATEX Entry level series into precision pressure
More informationPressure switch Type BCP
Data sheet Pressure switch Type BCP The BCP type is a series of dedicated switches for safety and monitoring of steam and hot water boilers. The BCP incorporates a single-pole changeover microswitch where
More informationType S-10, S-11 General Purpose Pressure Transmitters
Electronic Pressure Catalog > General Purpose > S-10, S-11 Type S-10, S-11 General Purpose Pressure Transmitters Applications Hydraulics and pneumatics Test equipment Pump and compressor control Liquid
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-20
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-10
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well
More informationRaising the bar. Philips Advance Optanium high efficiency instant start T8 ballasts have set new standards for maximizing energy savings
Raising the bar Philips Advance Optanium high efficiency instant start T8 ballasts have set new standards for maximizing energy savings Philips Advance Optanium high-efficiency electronic ballasts are
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-10
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well
More informationTightness controls TC 1 3 and TC 4
Tightness controls TC 1 3 and TC 4 Test of both safety valves Short test period thanks to logical decision-making in the program sequence Adjustable test period which can be adapted to different systems
More informationMB610 Industrial Pressure Transmitter
MB60 Industrial Pressure Transmitter Features Extreme Impact and vibration resistance, anti-overload, anti-corrosion; Digital compensation, wider operating ambient temperature range; High accuracy, low
More informationGasSense NDIR User Manual
INDEX INDEX... 1 1. OVERVIEW... 2 2. TECHNICAL DATA... 3 3. SPECIFICATIONS... 4 4. PRODUCT DESCRIPTION... 5 4.1 Mechanical details... 5 4.2 Piping... 7 4.3 Connections... 7 5. INSTALLATION... 10 6. CALIBRATION
More informationTechnical Data. Dimensions
00 Model Number Features mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,
More informationProgrammable pressure and temperature transmitters PTM/RS485
Programmable pressure and temperature transmitters PTM/RS485 Version: 26.06.2014 Technical Specifications Pressure measuring range (bar) 0.1... 0.5 > 0.5 2 > 2 25 Overpressure 3 bar 3 x FS ( 3 bar) 3 x
More informationTechnical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection
0102 Model Number Features Direct mounting on standard actuators Compact and stable housing Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up to SIL2 acc. to IEC 61508 Accessories
More informationParametrable / Programmable Pressure Transmitter
Parametrable / Programmable Pressure Transmitter PTM/RS485 CUSTOMER BENEFITS High flexibility due to scalalbe pressure range Digital (RS485) and analogue (4-20mA) output signal in one sensor Available
More informationProgrammable pressure and temperature transmitters PTM/RS485
Programmable pressure and temperature transmitters PTM/RS485 Version: 03-28-2012 Technical Specifications Pressure measuring range (bar) 0.1... 0.5 > 0.5 2 > 2 25 Overpressure 3 bar 3 x FS ( 3 bar) 3 x
More informationSorensen DCS Series. 1 3 kw V A. General Purpose Systems Power Supply
Sensen DCS Series General Purpose Systems Power Supply High power density / low ripple and noise High programming resolution with Ethernet interface Constant voltage and current mode Remote sensing Isolated
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 5 mm
00 Model Number Features 5 mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,
More informationDMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.
Pressure Transmitter for Marine and Offshore Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0. % FSO Nominal pressure from 0... 40 mbar up to 0... 0 bar Output signals -wire:
More informationOperating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073
Operating instructions Safety Rope Emergency Stop Switches UK ZB0052 / ZB0053 ZB0072 / ZB0073 7390878 / 02 03 / 2011 Contents 1 Safety instructions...3 2 Installation / set-up...4 2.1 Applications...4
More informationSpeed Controller ADR 40 Condensing pressure controller SPEED REGULATORS FOR ASYNCHRONOUS SINGLE PHASE MOTORS SERIES ADR 40 ADR 40 ADR 40 PP
SPEED REGULATORS FOR ASYNCHRONOUS SINGLE PHASE MOTORS SERIES ADR 40 ADR 40 ADR 40 PP Control by pressure or temperature Pressure control 0-50 bar for all refrigerants Temperature control -20 to +100 C
More informationGenesis MX SLM-Series
Single Frequency Visible OEM and End-User OPS Laser Systems Applications like Flow Cytometry, Particle Counting, DNA Sequencing and Microscopy are enable by low noise, visible true CW lasers. The Genesis
More informationModel PDT Dewpoint Transmitter
Model PDT Dewpoint Transmitter Instruction Manual Alpha Moisture Systems Alpha House 96 City Road Bradford BD8 8ES England Tel: +44 1274 733100 Fax: +44 1274 733200 email: mail@amsytems.co.uk web: www.amsystems.co.uk
More informationSensor for Air Bubble Detection at Liquid Filled Tubes. SONOCHECK Type ABD06.xx. Operating Manual
Sensor for Air Bubble Detection at Liquid Filled Tubes SONOCHECK Type ABD06.xx Operating Manual Manufacturer: Model: Type: SONOTEC Ultraschallsensorik Halle GmbH Air Bubble Detector ABD06.xx SONOTEC Ultraschallsensorik
More informationRPS900W Redundant Power Supply. Installation Guide.
RPS900W Redundant Power Supply Installation Guide www.edge-core.com Installation Guide RPS900W Redundant Power Supply Single DC Output Port with Dual Output Voltages RPS900W E10013-CS-R01 1500000081A
More informationPressure transmitters EMP 2
Data sheet Pressure transmitters EMP 2 The high accuracy pressure transmitter EMP 2 is designed for monitoring and control in marine and industial applications and offers a reliable pressure measurement,
More informationVPPC02, VPPC08 3-way proportional pressure control valve, electronic closed loop control
VPPC, VPPC -ay proportional pressure control valve, > > Nominal diameter,, flange version G/ > > Visual function display (optional) > > Compact and lighteight design > > Field bus capable as part of a
More informationHUMOR 20 HUMOR 20. High-precision Humidity Calibrator. Water T, p1
High-precision Humidity Calibrator The role of humidity calibrations that are accurate, reproducible, and documentable is becoming more and more important. ISO quality guidelines and regulations according
More informationProportional pressure regulators VPPE
Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/
More informationPRODUCT SPECIFICATION
MINI-FIT SR. SERIES 1.0 SCOPE This specification covers the 10.00 mm / (.394 in.) centerline tin and gold plated connector series, single and dual row versions in wire to wire and wire to printed circuit
More informationInductive Linear Displacement Transducers Model IW 260 Measuring strokes: 80 mm, 170 mm, 240 mm, 360 mm
Inductive Linear Displacement Transducers Model IW 260 Measuring strokes 80, 170, 240, 360 Document no. IW 100 HE Date 1.07.201 Contactless, robust sensor system Infinite resolution, no hysteresis Calibrated
More informationHigh-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements
More informationCONTENTS TABLE OF MAIDA S HISTORY TERMINOLOGY & GENERAL SPECIFICATIONS. iii. LEAD CODES and TAPE & REEL STANDARD SERIES 1 HC SERIES 17
TABLE OF CONTENTS MAIDA S HISTORY TERMINOLOGY & GENERAL LEAD CODES and TAPE & REEL i ii iii STANDARD SERIES 1 HC SERIES 17 LOW PROFILE SERIES 33 THERMALLY PROTECTED SERIES 39 HIGH ENERGY SERIES LEAD CODES
More informationTH-1800-T TRX-700-CNG Converter
TH-1800-T TRX-700-CNG Converter low detector The CNG fuel gas flowmeter is so accurate as to meet a demand of measuring the CNG directly by making the most use of our well-established mini-thermal flowmeter
More information1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure
Siemens AG 204 Overview The pressure transmitter SITRANS P220 measures the gauge pressure of liquids, gases and vapors. Stainless steel measuring cell, fully welded Measuring ranges 2.5 to 600 bar (36.3
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-20
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater
More informationDimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm
Dimensions 65 GW2 40 35 9 5 GW1 14 11 9 5.4 M20 x 1.5 0102 Model Number S M12 x 1.5 Features 77.5 LED V Direct mounting on standard actuators Compact and stable housing with terminal compartment connection
More informationZelio Relays RSL Slim Interface Plug-In Relays
Zelio Relays RSL Slim Interface Plug-In Relays Catalog 8501CT0901 2009 Class 8501 CONTENTS Description............................................. Page Introduction.................................................3
More informationP9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6
P9000 High accuracy through digital compensation High thermal stability Rugged stainless steel construction Ideal for test stands High burst pressure limit DESCRIPTION The P9000 Series is a range of advanced,
More informationMiniature controls. Contactors. Overload relays. Starters. Control relays
Contactors Overload relays Starters Control relays Description General features Wiring terminations available include plugon connectors, wire pins for PC board mounting and solder connections Low power
More informationMV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:
MV-01 2/2-way Solenoid Valve for Fluids Description: Features / Nominal diameters 1/4-2 / Pressure up to 10 bar / 24 V DC and all common AC variants / Forced-lifting The pilot-controlled full-way valve
More informationProportional Pressure-Relief Cartridge Valve, Size 2...4
Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description proportional pressure-relief valves are direct acting
More informationContinuous Gas Analyzers, extractive
Overview Plug-in and field device The gas analyzer is primarily used to identify a gas component quantity (e.g. H 2, N 2, Cl 2, HCl, NH 3 ) in binary or quasi-binary gas mixtures. The is specially designed
More informationTANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR
SIT Group 836-837 TANDEM MULTIFUNCTIONAL GAS CONTROL MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR ALL ADJUSTMENTS ACCESSIBLE FROM ABOVE
More information2/2-Way Proportional Valve (motor-driven)
2/2-Way Proportional Valve (motor-driven) Type 3280 can be combined with Seat valve with stepper motor - actuator isolated from flow path Excellent range (1:100) Low power consumption Fast response Orifice
More informationLMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.
LMP 07 Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % / 0. % FSO Nominal pressure from 0... mho up to 0... 50 mho Output signals -wire: 4... 0 ma -wire: 0...
More informationSPECIFICATION. 3in1 LTE MIMO + GNSS Antenna
SPECIFICATION Part No. : MA250.A.LBI.001 Product Name : Sentinel Adhesive Mount 3in1 LTE MIMO + GNSS Antenna Feature : Ideal for IoT and Automotive Applications Smallest High Performance MIMO 2 x LTE 4G/3G/2G
More informationInverse Prop. Pressure-Relief Cart., Size 2 4
Inverse Prop. Pressure-Relief Cart., Size Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description inverse proportional pressure-relief valves are direct acting screw-in
More informationTechnical Data. Dimensions
0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications
More informationCONTENT. Report No.: GZ R6. Page 2 of 17
CONTENT TEST REPORT... 1 CONTENT... 2 1 TEST RESULTS SUMMARY... 3 2 EMC RESULTS CONCLUSION... 4 3 LABORATORY MEASUREMENTS... 6 4 HARMONIC OF CURRENT... 7 4.1 USED TEST EQUIPMENT... 7 4.2 BLOCK DIAGRAM
More informationOPERATION & INSTALLATION INSTRUCTIONS
Reliable Golf Course Supplies Rev. A 6/30/98 OPERATION & INSTALLATION INSTRUCTIONS Congratulations on your purchase of Reliable Golf Course Supplies Tee Sentry. Your shipment should include the following
More informationATM/Ex - Analog Pressure Transmitter
Pressure Transmitter - ATEX certified ATM/Ex - Analog Pressure Transmitter CUSTOMER BENEFITS Certificate: ATEX & EAC Fast customization thanks to configurable product design Demountable electrical connector
More informationPROGRAMMER OPERATIONS MANUAL
PROGRAMMER OPERATIONS MANUAL Table of Contents Description 4 Installation 4 Operation 5 Safety Precautions 5 Regulatory & Service Information 6 Important Safety and Usage Information 7 Regulatory Notices
More informationATM/Ex - Intrinsically Safe Analog Pressure Transmitter - ATEX / IECEx Certified
Intrinsically safe pressure transmitters ATM/Ex - Intrinsically Safe Analog Pressure Transmitter - ATEX / IECEx Certified CUSTOMER BENEFITS Certificate: ATEX & IECEx Fast customization thanks to configurable
More informationATM - Analog Pressure Transmitter
Pressure Transmitter ATM - Analog Pressure Transmitter CUSTOMER BENEFITS Fast customization thanks to configurable product design Demountable electrical connector option to allow adjustment of zero and
More informationThe Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure
General-purpose Limit Switch CSM_DA-_N_DS_E The Limit Switch with Better Seal, Shock Resistance, and Strength A double seal on the head, a complete gasket cover, and other features ensure a better seal
More information1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition
Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.
More informationUNIK 5600/5700 Marine Certified Pressure Sensing Platform
GE Measurement & Control UNIK 5600/5700 Marine Certified Pressure Sensing Platform The new UNIK 5600/5700 carries marine certification for most zones on-board ship, as well as Intrinsically Safe certifications.
More informationVSD03M DIRECTIONAL CONTROL VALVES
NFPA SIZE D03 TYPICAL PERFORMANCE SPECIFICATIONS Performance is measured on a four-way circuit (full circuit). Performance may e reduced from that shown if a three-way circuit (half circuit) is used, i.e.
More informationServo UNIVERSAL ADVANCED VENTILATION PLATFORM ALL PATIENT CATEGORIES
DATA ADVANCED VENTILATION PLATFORM ALL PATIENT CATEGORIES CRITICAL CARE HIGHLIGHTS! For all patient categories, from neonate and pediatric to adult! A platform for the future choose the level of system
More informationP900. P900, Datenblatt Seite 1 DESCRIPTION
, Datenblatt Seite 1 Field proven rugged construction High overpressure capability High reliability for demanding environments Application specific customization Excellent media compatibility Shock and
More informationRELAY PRODUCT GUIDE CONTENTS
RELAY PRODUCT GUIDE CONTENTS 1.0 ABOUT FUJITSU COMPONENTS 1.1 Who we are Page 2 2.0 PRODUCT LINE-UP 2.1 Automotive relays Page 3 2.2 Power relays Page 8 2.3 Signal relays Page 16 2.4 High frequency relays
More informationUser manual. PG89 Rev 01 Editi Pressotherapy model. LymphoPress 4
User manual PG89 Rev 01 Editi 040515 Pressotherapy model LymphoPress 4 I.A.C.E.R. Srl Via S. Pertini 24/A 30030 Martellago (VE) ITALY Tel. 041.5401356 Fax 041.5402684 e-mail: iacer@iacer.it http://www.itechmedicaldivision.com
More informationOPTIBAR P 1010 C Technical Datasheet
Technical Datasheet Pressure transmitter with recessed diaphragm for general applications Wide variety thanks to modular design Measuring ranges up to 250 bar / 3750 psi High overload and temperature stability
More informationPressure Automated Calibration Equipment
GE Measurement & control Pressure Automated Calibration Equipment Safety Instructions and User Guide - K0447 PACE5000 PACE6000 K0447 Issue No. 9 1 10 1 PACE5000 1 2 3 4 5 PACE6000 2 6 7 8 3 4 5 6 7 8 9
More informationFMAC Sine FMAC Sine DCL
emc Sine Output Filter www.schurter.com/pg8 FMAC Sine FMAC Sine DCL -Phase Filters Sine wave output filter Description - Design corresponding to UL 128, CSA 22.2 No. 8, IEC/EN699 - Standard versions include
More informationTechnical Data. Dimensions
0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable
More informationWAGO-I/O-SYSTEM 750 XTR Taking it to the extreme The Standard for 750 XTR
WAGO-I/O-SYSTEM 750 XTR Taking it to the extreme The Standard for 750 XTR TAKING IT TO THE extreme The Standard for 750 XTR extreme temperatures extreme isolation extreme vibrations from 40 C to +70 C
More informationTechnical Data. Dimensions
00 Model Number Features Comfort series 30 mm non-flush Accessories MHW 0 Modular mounting bracket V-G Female connector, M, 4-pin, field attachable V-W-N-M-PUR Female cordset, M, -pin, NAMUR, PUR cable
More informationDPS-400 SERIES DPH-100 SERIES
745 Dual Display Digital Pressure Sensor For Gas DPS-400 SERIES SERIES General terms and conditions... F- guide... P.699~ Related Information Glossary of terms... P.156~ General precautions... P.1566 PHOTO
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 1.5 mm
0102 Model Number Features 1.5 mm flush Accessories BF 8 Mounting flange, 8 mm Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 1.5 mm Installation flush
More informationP499 Heavy Duty Pressure Transducer
P499 Heavy Duty Pressure Transducer Product Bulletin Code No. LIT-??? E Issued 11 2006 The P499 Series is a new global Pressure Transducer with an excellent price performance ratio. The P499 exceeds the
More informationGasBloc Multifunctional gas control Combined regulator and safety shut-off valves single-stage atmospheric operating mode GB-(LEP) 057 D01
Gasloc Multifunctional gas control Combined regulator and safety shut-off valves single-stage atmospheric operating mode G-(LEP) 057 D01 3.10 Printed in Germany Edition 05.11 Nr. 249 584 1 6 Technical
More informationOld documentation - Only for your information! Product is not available any more!
Gasloc Multifunctional gas control Combined regulator and safety shut-off valves single-stage atmospheric operating mode G-(LEP) 057 D01 3.10 Technical description Multifunctional gas control valve as
More informationMass Flow Meter (MFM) for gases
Mass Flow Meter (MFM) for gases Type can be combined with Inline MFM for nominal flow rates from 25 l N /min to 1,500 l N /min; 1/4 to 3/4 High accuracy Fast settling time Fieldbus option Special version
More informationDifferential pressure controls, Type MP 54, 55 and 55A
MAKING MODERN LIVING POSSIBLE Technical brochure Differential pressure controls, Type MP 54, 55 and 55A MP 54 and oil pressure controls are used as safety switches to protect refrigeration compressors
More informationControl and Automation
GE Consumer & Industrial Power Protection Control and Automation Electronic relays GE imagination at work Electronic relays Order codes F.3 Series DM Single voltage electronic timers. 22.5mm module F.4
More information