Schedule of Quantity and Rate for Annual Maintenance Rate Contract for Electrical Jobs for the year (Section-F) Cleaning Jobs.

Size: px
Start display at page:

Download "Schedule of Quantity and Rate for Annual Maintenance Rate Contract for Electrical Jobs for the year (Section-F) Cleaning Jobs."

Transcription

1 Schedule of and for Annual Maintenance Contract for Electrical Jobs for the year (Section-F) Cleaning Jobs Cleaning of cable trenches of various sizes from 450 mm wide x 600 mm deep to 1000 mm wide x 1250 mm deep containing MS angle/support including cleaning, scraping rust from each arm of cable rack support and its other chambers, nuts and bolts etc. and then applying two coats of rust preventor and two coats of epoxy paints Removal of Heavy duty slab above 10 cm thick and placing them back on the cable trench. Removal of Light duty slab upto 10 cm. thick and placing them back on the cable trench. Nos 64 Nos Cleaning and removal of rust from cable/cable racks and various arms, application of rust preventor and epoxy paint on all cable/cable racks. Mtr. 273 Dencote/ anti corrosive paint Cleaning of cable trench of various width. Removal of rubbish containing ash, coal, fuel oil, accumulated water filled trenches, stacking and disposal of the same. The choked drain outlets of the cable trenches are also to be cleaned with water jets. Sealing of slab joints of cable trenches with premixed sand bitumen (250mg of bitumen of 80/100 grade is to be mixed with one cubic meter of river sand ). Surface dressing uprooting of small bushes along the cable trenches 30 cm wide from both side of the trench and disposed of rubbish at nearest available place. MTR 282 MTR 1000 Bitumen Compound MTR 338 Signature of Issuing Authority Page 1 of F Signature of the Contractor with seal

2 2.00 Cleaning of motors parts such as body, fan covers, foundation bed, radiator, push button station, site isolator etc From fractional H.P to 5HP/3 KW.(420 Nos. per round x 24 above 5 HP to 20 HP/15 KW(125 Nos. per round x 24 Nos Nos 3000 Min.288 No. mandays are 2.03 Above 20 HP to 40 HP/27 KW(150 Nos. per round x 24 Nos Above 40 HP to 200HP/149 KW(131 Nos. per round x 12 Above200HP/149 KW (84 Nos. per round x 12 Nos 1572 Nos 1008 Min.180 No. mandays are 3.00 Cleaning of power panels, lighting panels, lighting board, sub lighting distribution boards, small power or control panel etc. (106 Nos. per round x 12 Nos 1272 Polishing liquid or cream Min. 300 No. mandays are 4.00 CLEANING OF TRANSFORMERS /10 MVA and 35 MVA (10 Nos. per round x 12 Nos 120 Min. 240 No. mandays are KVA, 2000 KVA and 2250 KVA (22 Nos. per round x KVA & 750 KVA (20 Nos. per round x 12 Nos 264 Nos 240 Min. 240 No. mandays are Min.108 No. mandays are 4.04 Small transformers below 750 KVA.(28 Nos. per round x 12 Nos 372 Min. 72 No. mandays are Signature of Issuing Authority Page 2 of F Signature of the Contractor with seal

3 5.00 Cleaning of substations/transformers rooms/bays Large sized substations including basement such as main substation /ammonia substation/sgp substation. (Surface area 2800 sq mm and above).(3 Nos. per round x 12 Nos 36 Min.240 No. mandays are 5.02 Medium substations such as coal handling substation,soot blower MCC rooms, Ammonia MCC 2, 5000 Te ammonia storage MCC, BFW MCC room, 4th boiler substation, HCN chromate, 10 MVA transformers bay, 1750 KVA transformer bays of unit group of plants and expansion plants, 1250 KVA sub-station, 750KVA sub-station, emergeny diesel gen. station.(surface area 600 sq mtrs.) (80 Nos. per round x 12 Nos 960 Min.360 No. mandays are 5.03 Small substations/transformer bays etc. such as fly wheel MG sets room / UPS rooms, battery rooms, filter rooms or any other small substation/transformer bay etc.(surface area below 600 sq m) (60 Nos. per round x 12 Nos 720 Min.240No. mandays are 6.00 Cleaning of cable racks and trays in carbon recovery /urea plant, SGP (around boilers1, 2 & 3), NOX plant, NLSP, Silo(CAN & Urea) & Bagging(CAN & Urea).The cable racks and trays laid horizontally are to be cleaned of dust, oil, coal dust mixture and cleaning with jute brush Cable trays/racks of size 15cm wide (3000 Metre per round x 4 Cable trays/racks of size 30 cm wide(3285 Metre per round x 4 MTR MTR Min.160 No. mandays are Signature of Issuing Authority Page 3 of F Signature of the Contractor with seal

4 6.03 Cable trays/racks of size 45cm wide(1300 Metre per round x 4 MTR 5200 Min.120 No. mandays are 6.04 Cable trays/racks of size 60 cm wide(3700 Metre per round x 4 MTR Min.432 No. mandays are Cable trays/racks of size 100cm wide(3500 Metre per round x 4 MTR Uprooting /trimming /pruning trees coming up beneath over-head lines.uprooting of bushes around over-head lines,poles and substations. Min.320 No. mandays are Trimming /pruning /uprooting of trees coming up beneth the over-head net work if any. (1250 No.per round x 6 Uprooting of bushes (small trees) grass and wild growth,surface dressing around 9 sq meters of each RCC/steel tubular poles and then disposal of rubbish at the nearest suitable place. (200 No.per round x 12 Nos 7500 Nos of poles 2400 Min.120 No. mandays are Min.240No. mandays are 7.03 Uprooting of bushes (small trees) grass and wild growth,surface dressing around 400 sq meters of each substation. (20 No.sub-station per round x 4 Sq meter Min.80 No. mandays are 7.04 Uprooting of wild growth/grass from the pebbels in the 66 KV Switch Yard, W.T. Plant and out sides of 66 KV Switch-Yard(6000 sq.mr. per round x 6. Sq meter Min.360 No. mandays are 8.00 Cleaning of Battry Bank (fortnightly) in different sections as per their Voltages mentioned below: V Battery Bank (7 nos. 24 V Banks per round x 24 round) Nos 168 Petroleum Jelly Signature of Issuing Authority Page 4 of F Signature of the Contractor with seal

5 V/50 V Battery Bank (5 nos. Banks per round x 24 round) Nos V Battery (6 nos. Banks per round x 24 round) Nos V/240V Battery Bank (10 no Banks per round x 24 round) Nos V Battery Bank (6 no Banks per round x 24 round) Nos 144 Cleaning of air filters of following sizes installed in the various substations for pressurisation equipments. It includes removal of filters, cleaning with water and pressurised air, refixing of filters after cleaning and drying, replacement of filters. Petroleum Jelly Min.288 No. mandays are Min.192 No. mandays are Filter size upto 600 x 600 mm.( Upto 3600 Sq. mm.) (10 Nos. Filter per round x 12 round) Nos 120 Filter size upto 1000 x 500 mm.( Upto Sq. mm.) (6Nos. Filter per round x 12 round) Nos 72 Paper Filter Sets of Tranformer oil.this includes removing of filters from oil filteration set and refixing the same after cleaning.(6 Nos. Filter per round x 12 round) Cleaning of Surge counter / lightening arrestor/ Bushing / Insulators of T/ship & switchyard. Nos 72 Nos 600 Min.80 No. mandays are Cleaning of gravels in transformer pits 35 MVA /10 MVA /1750 KVA/ 1250 KVA / 1000 KVA / 750 KVA (50 Nos. Transformer Pits) Nos 50 Min.500 No. mandays are TOTAL Signature of Issuing Authority Page 5 of F Signature of the Contractor with seal

FINAL FACILITY STUDY. KV1C Transformer Addition at Badwater Substation 2009-T1. November 17, 2009

FINAL FACILITY STUDY. KV1C Transformer Addition at Badwater Substation 2009-T1. November 17, 2009 FINAL FACILITY STUDY KV1C Transformer Addition at Badwater Substation 2009-T1 November 17, 2009 I. Introduction In October 2008, Western Area Power Administration (Western) received a Transmission Queue

More information

" High Voltage Switch Yards & How Safe are these really" <Peter Rhodes> <Principal and High Voltage Solution. Com Ltd>

 High Voltage Switch Yards & How Safe are these really <Peter Rhodes> <Principal and High Voltage Solution. Com Ltd> " High Voltage Switch Yards & How Safe are these really" High Voltage Forum Brisbane 2013 Duty of Care As part of an asset owner Duty of care

More information

Kodiak Electric Renewable Energy Implementation. Colin Young System Engineer 4/26/2016

Kodiak Electric Renewable Energy Implementation. Colin Young System Engineer 4/26/2016 Kodiak Electric Renewable Energy Implementation Colin Young System Engineer 4/26/216 Kodiak Electric Territory 216 Grid Kodiak Board Members Create a Vision in 25 Endeavor to produce 95% of energy sales

More information

TEST BENCH FOR SAFETY VALVES

TEST BENCH FOR SAFETY VALVES TEST BENCH FOR SAFETY VALVES 1) Hydro panel : This Panel possesses This Bench Contains One Panel and One Reservoir. 1 No. Monobloc Version : Single Phase AC, 50 Hz Type of Duty :S1 (Continuous) Class of

More information

TURBO OXYGEN NITROGEN PLANT

TURBO OXYGEN NITROGEN PLANT TURBO OXYGEN NITROGEN PLANT WITH LATEST ROTARY AIR COMPRESOR PICTORIAL FLOW CHART OF THE LOW PRESSURE TURBO AIR SEPARATION PLANT FOR OXYGEN & NITROGEN. SALIENT FEATURES EASY TO INSTALL VERY LOW POWER CONSUMED

More information

Using propane cylinders safely

Using propane cylinders safely Using propane cylinders safely This leaflet is for the safe use of Calor Gas propane cylinders. If you have any queries please contact your local retailer. Calor supplies Liquefied Petroleum Gas (LPG)

More information

CompAir provide high quality and reliable Nitrogen solutions

CompAir provide high quality and reliable Nitrogen solutions Nitrogen Compressor Guide CompAir provide high quality and reliable Nitrogen solutions Technical Data Model Typical Inlet Pressure Max Pressure Typical FAD Drive Bar PSI Bar PSI m³/hr CFM kw HP 5209 B

More information

Selection of Electrical PPE Tables

Selection of Electrical PPE Tables Selection of Electrical PPE Tables Instructions Table 1 - Starting with Table 1, select the task you plan to do (right-hand column) and the condition of the equipment you will be working on, (center column).

More information

VERTICAL AIR COMPRESSORS

VERTICAL AIR COMPRESSORS VERTICAL AIR COMPRESSORS MODEL NO: VE15C150, VE18C150, VE25C150 PART NO: 2226010, 2226020, 2226025 OPERATION & MAINTENANCE INSTRUCTIONS LS0715 INTRODUCTION Thank you for purchasing this CLARKE Vertical

More information

VERSION 1 SUMP PUMP PIT UNIT KAWAMOTO PUMP ASIA CO.,LTD.

VERSION 1 SUMP PUMP PIT UNIT KAWAMOTO PUMP ASIA CO.,LTD. SUMP PUMP PIT UNIT FEATURES All needed parts are assembled and united as a sump pit and easy to install for short period. Sump tank is made of SUS with epoxy coating and pipe is integrated by stainless

More information

VERTICAL AIR COMPRESSORS

VERTICAL AIR COMPRESSORS VERTICAL AIR COMPRESSORS MODEL NO: VE11C150, VE15C150, VE18C150 PART NO: 2226005, 2226000, 2226015 OPERATION & MAINTENANCE INSTRUCTIONS LS0615 INTRODUCTION Thank you for purchasing this CLARKE Vertical

More information

Operators & Maintenance Manual OPERATOR S MANUAL USAGE AND MAINTENANCE F100M F100M. Powered Fixed Hoist Ideal for raised swimming pools and hot tubs

Operators & Maintenance Manual OPERATOR S MANUAL USAGE AND MAINTENANCE F100M F100M. Powered Fixed Hoist Ideal for raised swimming pools and hot tubs MIllside House Anton Road Andover Hampshire SP10 2RW T: +44 (0)1256 896000 E: info@poollifts.co.uk Operators & Maintenance Manual OPERATOR S MANUAL USAGE AND MAINTENANCE F100M F100M Powered Fixed Hoist

More information

TB 42. Low maintenance effort saves on time and costs. High variability for vehicle types, construction and expan- sion options

TB 42. Low maintenance effort saves on time and costs. High variability for vehicle types, construction and expan- sion options TB 42 TB 42 commercial vehicle wash for automatic exterior cleaning. The 3-brush gantry allows a washing height of 4.25 m and offers total flexibility for different vehicle sizes and types. 1 Low maintenance

More information

INSTRUCTION MANUAL MST AFTERCOOLER SYSTEM MODEL

INSTRUCTION MANUAL MST AFTERCOOLER SYSTEM MODEL INSTRUCTION MANUAL MST AFTERCOOLER SYSTEM MODEL 8059601 To be used with MST Model 8050501 Ambient Air Pump 7/12/05 2 TABLE OF CONTENTS GENERAL INFORMATION... 3 WARNING...4,5 UNPACKING AND AFTERCOOLER ASSEMBLY

More information

ATV 90 Y-12 YOUTH 2-STROKE RED (A2004ATB2BUSR) Page 1 of 52 A-ARM, FLOOR PANEL, AND BUMPER ASSEMBLY

ATV 90 Y-12 YOUTH 2-STROKE RED (A2004ATB2BUSR) Page 1 of 52 A-ARM, FLOOR PANEL, AND BUMPER ASSEMBLY 2004 ATV 90 Y-12 YOUTH 2-STROKE RED (A2004ATB2BUSR) Page 1 of 52 A-ARM, FLOOR PANEL, AND BUMPER ASSEMBLY 2004 ATV 90 Y-12 YOUTH 2-STROKE RED (A2004ATB2BUSR) Page 2 of 52 A-ARM, FLOOR PANEL, AND BUMPER

More information

Fire Safety Hot Work Permit Policy/ Procedures

Fire Safety Hot Work Permit Policy/ Procedures Fire Safety Hot Work Permit Policy/ Procedures INTRODUCTION Serious fires frequently occur during maintenance and construction operations, where work is proceeding on either machinery, plant or the fabric

More information

4 Machine maintenance and repair

4 Machine maintenance and repair 3.3 lift device consists of: lift motor, lead screw, guide rod, lifting seat Lift motor Lead screw Guide rod Lifting seat Diagram 3.3 3.4 torch holder set The torch holder consist of holder connection,

More information

HNP-021 Oil Purifier. Description. Specifications. Features. Contact Us:

HNP-021 Oil Purifier. Description. Specifications. Features. Contact Us: HNP-021 Oil Purifier Contact Us: www.pall.com/contact Description The HNP-021 has been developed as a conditioner for hydraulic, lubrication and dielectric oils. It removes free and dissolved water, dirt,

More information

Code AWC20HP Air Compressor

Code AWC20HP Air Compressor Code 951816 AWC20HP Air Compressor Index of Contents Index of Contents 02 Declaration of Conformity 02 What s Included 03 Safety Precautions 03 Specifications (AWC20HP Air Compressor) 04 Assembly Instructions

More information

Power Supply Facilities Failure (Units 3-4 Temporary M/C (A), etc.) March 22, 2013 Tokyo Electric Power Company

Power Supply Facilities Failure (Units 3-4 Temporary M/C (A), etc.) March 22, 2013 Tokyo Electric Power Company < Reference > Power Supply Facilities Failure (Units 3-4 Temporary M/C (A), etc.) March 22, 2013 Tokyo Electric Power Company Occurrence of Events in a Chronological Order At around 6:57 PM on March 18,

More information

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1 Dry 131h 1. DESCRIPTION The Viking Model G-1 Maintenance Air Compressor is an electric motor-driven, aircooled, single-stage, oil-less compressor. The unit is equipped with a check valve and provides a

More information

Manual Actuated Boiler Blowdown Valves

Manual Actuated Boiler Blowdown Valves Manual Actuated Boiler Blowdown Valves Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Operation 5. Maintenance 6. Spare parts p.1 1. Safety

More information

Bulletin Swimming pool, hot tub and spa installations Rules , , , , , and

Bulletin Swimming pool, hot tub and spa installations Rules , , , , , and Bulletin 68-7-11 Swimming pool, hot tub and spa installations Rules 68-000, 68-056, 68-058, 68-064, 68-068, 68-302 and 68-404 Scope (1) Swimming pools - general (2) Grounding & bonding (a) Bonding for

More information

Aquor House Hydrant V2

Aquor House Hydrant V2 Aquor House Hydrant V2 IN-WALL OUTDOOR FAUCET SYSTEM FLUSH-MOUNT QUICK-CONNECT SELF-DRAINING ANTI-SIPHON NON-FREEZE VBH-SERIES AQUOR HOUSE HYDRANT V2: WALL HYDRANT / FREEZELESS SILLCOCK Freezeless sillcock

More information

DEH Instructions. Three-Phase, Platform-Mounted Distribution Transformers

DEH Instructions. Three-Phase, Platform-Mounted Distribution Transformers g DEH 40050 Instructions Three-Phase, Platform-Mounted Distribution Transformers Introduction The equipment covered by these instructions should be operated and serviced only by competent technicians familiar

More information

Rates of various Line materials and Labour charges used in cost sheets for general works

Rates of various Line materials and Labour charges used in cost sheets for general works Rates of various Line materials and Labour charges used in cost sheets for general works SL.NO Particulars Unit Materials rate in Rs. Labour charges (Casual) in Rs 1 2 3 4 5 RCC Poles a) 9.5 M 350kg WL

More information

ATL R/V Atlantis AUXILIARY PLANT OPERATION APPENDIX OPERATING PROCEDURES

ATL R/V Atlantis AUXILIARY PLANT OPERATION APPENDIX OPERATING PROCEDURES 110 AIR CONDITIONING CHILLED WATER PLANT 1. Ensure power to water chiller controller and all fan coil unit controllers is on 2. Ensure chilled water expansion tank level is at its proper level 3. Ensure

More information

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION OCT2010 STOKVIS ENERGY SYSTEMS 96R WALTON ROAD EAST MOLESEY SURREY KT8 0DL TEL: 020 87833050

More information

The following is a walk-around that should be done on each day of use before starting the airboat.

The following is a walk-around that should be done on each day of use before starting the airboat. Do not enter the cage area for any reason unless the key switch and battery switch are both in the off position. Audibly alert and visually check for people in the cage area, path of the propellers or

More information

C-Consequence, P Probability, R-Risk Rating Value Page 2 of 2

C-Consequence, P Probability, R-Risk Rating Value Page 2 of 2 General Procedure SE-GEN-04 azard nalysis & ssessment, Identification of Environmental spect and Impact ssessment P-474 / R / 01 Rev : 02 Date: 0.01.2012 CTIVITY RISK SSESSMENT WORKSEET Work ctivity: ocation:

More information

Vacuum Excavation in the vicinity of the Wellington Electricity Network

Vacuum Excavation in the vicinity of the Wellington Electricity Network Vacuum Excavation in the vicinity of the Network. Document no: ENG-116 Document Rev: 1 Issue Status: Final Issue Date: 14/05/2015 Page 1 of 9 Contents 1. PURPOSE... 3 2. POLICY... 3 3. SCOPE... 3 4. REFERENCES...

More information

Self-supporting hot water high pressure cleaner on trailer Hudson 315

Self-supporting hot water high pressure cleaner on trailer Hudson 315 Self-supporting hot water high pressure cleaner on trailer Hudson 315 High pressure system mounted in a Waterkracht single-axle trailer, with flip top. The trailer is made of stainless steel top and galvanised

More information

This training does not attempt to cover all safety regulations or precautions.

This training does not attempt to cover all safety regulations or precautions. This training does not attempt to cover all safety regulations or precautions. For additional safety regulations and precautions, see the following standards: American Welding Society (AWS) American National

More information

INTERPLANT STANDARD - STEEL INDUSTRY CODE OF PRACTICE FOR SELECTION, Corresponding IS does not exist

INTERPLANT STANDARD - STEEL INDUSTRY CODE OF PRACTICE FOR SELECTION, Corresponding IS does not exist INTERPLANT STANDARD - STEEL INDUSTRY IPSS CODE OF PRACTICE FOR SELECTION, LAYING OF MOIST FUEL GAS LINES Corresponding IS does not exist IPSS:1-06-014-17 (Third Revision) Formerly : IPSS:1-06-014-02 (Second

More information

1. PARTS INTRODUCTION ELECTRICAL NOTES INSTALLATION 5/6. 5. START UP 6/7. 6. MAINTENANCE 7/8/9. 7. PRESSURE SWITCH ADJUSTMENTS 9/10.

1. PARTS INTRODUCTION ELECTRICAL NOTES INSTALLATION 5/6. 5. START UP 6/7. 6. MAINTENANCE 7/8/9. 7. PRESSURE SWITCH ADJUSTMENTS 9/10. CONTENTS 1. PARTS 3. 2. INTRODUCTION 4. 3. ELECTRICAL NOTES 5. 4. INSTALLATION 5/6. 5. START UP 6/7. 6. MAINTENANCE 7/8/9. 7. PRESSURE SWITCH ADJUSTMENTS 9/10. 8. ELECTRICAL CONNECTIONS 10/11. 9. SPECIFICATIONS

More information

Deep Well Submersible Pump Model MSU/MSUS

Deep Well Submersible Pump Model MSU/MSUS Instruction Manual Installation Manual Deep Well Submersible Pump Model MSU/MSUS Thank you for your purchase of the Deep Well Submersible Pump. To the customers Instruct the dealer (installation contractor)

More information

IDEAS FOR MATHS TRAILS

IDEAS FOR MATHS TRAILS IDEAS FOR MATHS TRAILS These ideas were put together by the teachers attending maths courses in the Autumn term. Some are specific to the venue of the courses, or to the teachers own schools, but can almost

More information

AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: CHAMP 3 PART NO: LS0115

AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: CHAMP 3 PART NO: LS0115 AIR COMPRESSOR MODEL NO: CHAMP 3 PART NO: 2225222 OPERATION & MAINTENANCE INSTRUCTIONS LS0115 INTRODUCTION Thank you for purchasing this CLARKE Air Compressor. Please read this manual fully before use

More information

Long term stability tests of INO RPC prototypes

Long term stability tests of INO RPC prototypes Long term stability tests of INO RPC prototypes While the problem of sudden aging in the glass RPC prototypes is being investigated, a few RPCs of dimension 40 cm 30 cm were fabricated, using glass procured

More information

General No. 25 and D-25 Handy Operating Instructions

General No. 25 and D-25 Handy Operating Instructions General No. 25 and D-25 Handy For 1-1/4 through 3 lines (30mm 75mm) No. 25 Handy D- 25 Handy This tool is designed to give you years of trouble-free, profitable service. However, no machine is better than

More information

24 Litre Air Compressor

24 Litre Air Compressor Operator s Manual 24 Litre Air Compressor WARNING! Before using this appliance, read the Operator s manual and follow all its safety rules and instructions. SPECIFICATION Model Power ITEM DATA HWKAC2 1Kw/1.5HP&1.5Kw/2HP&1.8Kw/2.5HP

More information

Trench Cable Rollers - Straight Pulling Application

Trench Cable Rollers - Straight Pulling Application Trench Cable Rollers - Straight Pulling Application Straight Cable Roller Straight Cable Roller - Heavy Duty Two Casing Supports, Roller body made of Precision Steel Tube. German Bearings protected against

More information

D C P L OXYGEN / NITROGEN PLANT

D C P L OXYGEN / NITROGEN PLANT D C P L OXYGEN / NITROGEN PLANT DCPL MED SERIES OXYGEN CYLINDER FILLING PLANTS (Industrial Oxygen & Medical Oxygen) O N 2 2 DCPL- MED- SERIES OXYGEN AIR COMPRESSOR / NITROGEN PLANTS AIR COMPRESSOR Air

More information

23.1 Functions, Basic Configuration, and Interfaces

23.1 Functions, Basic Configuration, and Interfaces 23 (6.6.D) SF 6 and Other Special Gases 23.1 Functions, Basic Configuration, and Interfaces 23.1.1 Functions The primary function performed by the SF 6 and other special gases system is to provide SF 6

More information

Spare parts list ( ) Spare parts list HDS 990

Spare parts list ( ) Spare parts list HDS 990 Spare parts list (5.952-855.0) Spare parts list HDS 990 13.10.2014 www.kaercher.com EN Page 2 Page 3 Page 4 Table of contents Spare parts list HDS 990 (5.952-855.0)... 6 10 Individual parts... 7 49 Spare

More information

PressVal Pressurisation Units. Packaged Pressurisation Units with expansion vessels for heating systems.

PressVal Pressurisation Units. Packaged Pressurisation Units with expansion vessels for heating systems. PressVal Packaged with expansion s for heating systems. lamco Basepak LEXILLER lamco Basepak LEXILLER POWER AULT MUTE/ RESET SYSTEM OK lamco ON / O lamco Basepak LEXILLER PressVal SM skid mounted units

More information

Plumbing Products FLOOR DRAIN CLEANOUT GATE VALVE BALL VALVE.

Plumbing Products FLOOR DRAIN CLEANOUT GATE VALVE BALL VALVE. Plumbing Products FLOOR DRAIN CLEANOUT GATE VALVE BALL VALVE www.wilsontaylor.co INTRODUCTION Wilson Taylor Asia Pacific, headquartered in Singapore with a subsidiary based in Hong Kong and a representative

More information

24L AIR COMPRESSOR MODEL NO: TIGER 11/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

24L AIR COMPRESSOR MODEL NO: TIGER 11/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13 24L AIR COMPRESSOR MODEL NO: TIGER 11/250 PART NO: 2244010 OPERATION & MAINTENANCE INSTRUCTIONS LS01/13 INTRODUCTION Thank you for purchasing this product. Before attempting to use this product, please

More information

T17 Scrubber PARTS & CONSUMABLES

T17 Scrubber PARTS & CONSUMABLES T7 Scrubber PARTS & CONSUMABLES SERIAL # Only genuine Tennant parts can ensure peak performance for the life of your equipment. BRUSHES Excellent cleaning performance, designed and engineered specifically

More information

Materials : Carbon steel ASTM A216 WCB

Materials : Carbon steel ASTM A216 WCB Certificate 3.1 Size : Ends : Min Temperature : Max Temperature : DN 50 to DN 400 ( NPS 2" to 16" ) Flanges R.F. Class 150 (PN20) - 29 C + 425 C Max Pressure : 20 Bars Specifications : Removable stainless

More information

Water Mist Systems Inspection, Testing, and Maintenance of Water Mist Systems

Water Mist Systems Inspection, Testing, and Maintenance of Water Mist Systems Water Mist Systems Inspection, Testing, and Maintenance of Water Mist Systems Name of Property: Address: Phone Number: Inspector: Contract No.: Date: This Report Covers: Monthly Quarterly Annual Other

More information

Annex E(M) - Final inspection checklist - monowheel

Annex E(M) - Final inspection checklist - monowheel Annex E(M) - Final inspection checklist - monowheel A/C Reg... Owner...Kit S/N...Date... (U.K. Only) L.A.A No...Inspector...Insp. No... Note: This check list only covers specific items for inspection of

More information

50L BELT DRIVEN AIR COMPRESSOR

50L BELT DRIVEN AIR COMPRESSOR 50L BELT DRIVEN AIR COMPRESSOR MODEL NO: BOXER 14/50P PART NO: 2245200, 2245203 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS0118 - ISS 4 INTRODUCTION Thank you for purchasing this CLARKE

More information

Electric and Natural Gas Safety Slide Show Presenter s Notes

Electric and Natural Gas Safety Slide Show Presenter s Notes Contractor Beware Electric and Natural Gas Safety Slide Show Presenter s Notes Slide 1 Before darkening the room, offer a welcome and overview. Begin by introducing the program and its topic: Today s training

More information

Description. Chassis. Cabinet. Long chassis - Type: Dimensions (mm): 2700 x 1200 x 1678

Description. Chassis. Cabinet. Long chassis - Type: Dimensions (mm): 2700 x 1200 x 1678 1 ITV bench is equipped with a INJETVISION vision system whose purpose is to observe and study the jets from high pressure diesel injector in inert atmosphere (nitrogen or CO2) up to 50 bar (± 0.5 bar).

More information

100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13 100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: 2244025 OPERATION & MAINTENANCE INSTRUCTIONS LS01/13 INTRODUCTION Thank you for purchasing this product. Before attempting to use this product, please

More information

Airless-Spraying Equipment. SuperFinish31. Fully equipped. More power. Innovative QLS technology

Airless-Spraying Equipment. SuperFinish31. Fully equipped. More power. Innovative QLS technology Airless-Spraying Equipment SuperFinish31 Fully equipped More power Innovative QLS technology New technology, fully equipped with even more power. This is the new SuperFinish 31 Airless spraying equipment,

More information

Booster Pump PB4-60 Replacement Kits

Booster Pump PB4-60 Replacement Kits Booster Pump PB4-60 Replacement Kits FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product

More information

Step-by-Step Planning Guide

Step-by-Step Planning Guide B A C K Y A R D P L A N N I N G G U I D E Step-by-Step Planning Guide Whether you are considering purchasing a Michael Phelps Signature Swim Spa by Master Spas, or can t wait for yours to be delivered,

More information

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Models: EPS Single Pump EPT Twin Pump EPS-HP EPT-HP Single Pump High Pressure Twin Pump High Pressure

More information

i) Filtration machine, measuring equipment and other related machinery

i) Filtration machine, measuring equipment and other related machinery 5 MVA TRANSFORMER SERVICE AND MAINTENANCE FOR TATA CHEMICALS MAGADI. SAFETY MEASURES AND REQUIREMENTS i) A thorough site risk assessment to be done before commencement of work. ii) All personnel involved

More information

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS POP Safety Valve POP Safety Valve INTRODUCTION The effects of exceeding safe pressure levels in an unprotected pressure vessel or system, can have catastrophic effects on both plant and personnel. Safety

More information

2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version

2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version 2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version Type 6624 Impulse can be combined with... 10mm width orifice DN 0.8 to 1.2 with pressure range vacuum to 5bar medium separation, for

More information

SC100V AIR COMPRESSOR

SC100V AIR COMPRESSOR SC100V AIR COMPRESSOR OWNER S MANUAL FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE. SPECIFICATION ITEM DATA Model SC100V Power 2.2 Kw / 3 HP Voltage 230 V Frequency

More information

Product Sheet Spraymist Unit

Product Sheet Spraymist Unit Product Sheet Spraymist Unit DESCRIPTION The Spraymist unit is perfectly adapted for use with differents liquids for applications as metalcutting, drilling, grinding, cooling or wetting processes and chain

More information

: Electric Power Generation, Transmission, and Distribution. Region IV - OSHA

: Electric Power Generation, Transmission, and Distribution. Region IV - OSHA 1910.269: Electric Power Generation, Transmission, and Distribution Region IV - OSHA Scope This standard covers the operation and maintenance of electric power generation, control, transformation transmission,

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL USER S INFORMATION MANUAL UPFLOW, DOWNFLOW, UPFLOW/HORIZONTAL & HORIZONTAL ONLY INDUCED DRAFT GAS FURNACES Recognize this symbol as an indication of Important Safety Information If the information in this

More information

HIRE EQUIPMENT LIST BREATHING AIR EQUIPMENT. Mobile Breathing Air Units

HIRE EQUIPMENT LIST BREATHING AIR EQUIPMENT. Mobile Breathing Air Units BREATHING AIR EQUIPMENT Mobile Breathing Air Units HIRE EQUIPMENT LIST F9 110 or 240 volt Electric single phase unit, 8 cfm @ 145psig. BA20D Diesel driven unit, 20cfm @ 150psig c/w HP cylinder reserve.

More information

Innovative Pressure Testing Equipment

Innovative Pressure Testing Equipment Innovative Pressure Testing Equipment Oil & Gas Subsea Universities Nuclear Materials Science Supporting Industry and Research Worldwide www.kwdesign.co.uk Who are KW Designed Solutions? We are industry

More information

Distribution Transformer Instruction Manual

Distribution Transformer Instruction Manual Distribution Transformer Instruction Manual TABLE OF CONTENTS SHIPPING.. 3 INSPECTION ON RECEIPT 3 HANDLING.. 4 INTERNAL INSPECTION 5 STORAGE.. 6 LOCATION 6 PREPARING FOR SERVICE 7 PUTTING INTO SERVICE

More information

24L AIR COMPRESSOR MODEL NO: TIGER 8/260 PART NO:

24L AIR COMPRESSOR MODEL NO: TIGER 8/260 PART NO: 24L AIR COMPRESSOR MODEL NO: TIGER 8/260 PART NO: 1499490 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS0918 - ISS 2 INTRODUCTION Before attempting to use this product, please read this

More information

Risk Assessment for: Fume cupboards

Risk Assessment for: Fume cupboards School of Design Faculty of Performance, Visual Arts and Communications Risk Assessment for: Fume cupboards Assessment No: 117 PROCESS / ACTIVITY LOCATION ASSESSED BY DATE(S) Carrying out activities that

More information

Written Closure Plan. Comanche Station - Active CCR Surface Impoundment Public Service Company of Colorado Denver, Colorado

Written Closure Plan. Comanche Station - Active CCR Surface Impoundment Public Service Company of Colorado Denver, Colorado Written Closure Plan Comanche Station - Active CCR Surface Impoundment Public Service Company of Colorado Denver, Colorado October 17, 2016 Table of Contents 1.0 General Information... 1 2.0 Description

More information

-FRU FREEZE RESISTANT WATER VALVE COOLERS SYSTEM

-FRU FREEZE RESISTANT WATER VALVE COOLERS SYSTEM I N S TA L L AT I O N / I MN SA TA I N TL EL NAT AIN OC N E / MI AN IS NT RE UN CA TN I CO E N SI N S T R U C T I O N S INSTALLATION INSTRUCTIONS FOR -FRU OPTION Important: Read all instructions and refer

More information

$ Plan Review Fee when Permit Application is submitted HOT TUBS AND SPAS BUILDING PERMIT APPLICATION. COST: $80.

$ Plan Review Fee when Permit Application is submitted HOT TUBS AND SPAS BUILDING PERMIT APPLICATION. COST: $80. Community Development 1050 W Romeo Rd, Romeoville, IL 60446-1530 (815) 886-7200 Fax #: (815) 886-2724 Email: buildinginspections@romeoville.org HOT TUBS AND SPAS BUILDING PERMIT APPLICATION Application

More information

SPECIFICATION OF FIRE PROXIMITY SUIT

SPECIFICATION OF FIRE PROXIMITY SUIT SCHEDULE-V-I SPECIFICATION OF FIRE PROXIMITY SUIT Srl. No TECHNICAL SPECIFICATION Complied Not Complied Deviation, if any Page No. at which Tech Literature attached (1) (2) (3) (4) (5) (6) 1 Fire Fighting

More information

Arab Fertilizers Association Knowledge Sharing Template

Arab Fertilizers Association Knowledge Sharing Template In ammonia plant for abuqir 2 plant, during rising one of the workers to the top of absorption tower to check the trays of the absorption tower by crane suspended man basket. The crane shacked causing

More information

Contractors' Code of Safe Practice

Contractors' Code of Safe Practice Contractors' Code of Safe Practice Introduction As the controller of premises, The University of Hong Kong has a duty to ensure, so far as is reasonably practicable, the health and safety of all its employees,

More information

Parts Manual STRIKER Striker 2840 Parts List - PN Printed in USA 03/18/08

Parts Manual STRIKER Striker 2840 Parts List - PN Printed in USA 03/18/08 Parts Manual STRIKER 2840 Striker 2840 Parts List - PN 238155 - Printed in USA 03/18/08 Standard Parts Recommended General Wear Parts Ref No Part Description Qty Part No 1 Squeegee Hose Assembly

More information

6-5 Maintenance Manual

6-5 Maintenance Manual Non Return Valve 6-5 Maintenance Manual Contents 1. PRODUCT DESCRIPTION... 1 1.1 How it works... 1 1.2 Overall dimensions... 3 1.3 Technical datasheet... 4 1.3.1 Push flow situation... 4 1.3.2 Pull flow

More information

MiniMag. 1 of 8. The MiniMag scrubber s 2 recover drain are 80% larger than a 1.5, making the MiniMag scrubber s drain hose less likely to clog.

MiniMag. 1 of 8. The MiniMag scrubber s 2 recover drain are 80% larger than a 1.5, making the MiniMag scrubber s drain hose less likely to clog. MiniMag Scrubber tank doesn t bolt to the frame, and so is less likely to be damaged or risk to stripped out inserts. The heavy duty and thick walled poly tank, pivots on smooth bosses. The MiniMag scrubber

More information

24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS10/13

24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS10/13 24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: 2244030 OPERATION & MAINTENANCE INSTRUCTIONS LS10/13 INTRODUCTION Thank you for purchasing this product. Before attempting to use this product,

More information

Single-Phase Pad-Mounted Distribution. Single-Phase Pad-Mounted Distribution Transformers KVA

Single-Phase Pad-Mounted Distribution. Single-Phase Pad-Mounted Distribution Transformers KVA 62-10 Single-Phase Pad-Mounted Distribution Catolog Transformers Section Howard Industries, Inc. Certifi ed to ISO 9001:2015 62-10 Single-Phase Pad-Mounted Distribution Transformers 5-500 KVA 10002179

More information

SHHH AIR COMPRESSOR Model Nos. SHHH5/24 - SHHH5/50 - SHHH7/100

SHHH AIR COMPRESSOR Model Nos. SHHH5/24 - SHHH5/50 - SHHH7/100 SHHH AIR COMPRESSOR Model Nos. SHHH5/24 - SHHH5/50 - SHHH7/100 OPERATING & MAINTENANCE INSTRUCTIONS 0306 Thank you for purchasing this CLARKE Shhh Air silent running air compressor Before attempting to

More information

KTM 50 (DN ) Installation, maintenance and operating instructions

KTM 50 (DN ) Installation, maintenance and operating instructions 52 762-306 09.2014 KTM 50 (DN 100-200) Installation, maintenance and operating instructions General High-performing and compact, these pressure-independent control valves for variable flow heating and

More information

Innovative Techniques for Mitigating Arc Flash Exposure

Innovative Techniques for Mitigating Arc Flash Exposure Innovative Techniques for Mitigating Arc Flash Exposure Presented at MEMSA 2009 Annual Meeting & Technical Symposium 2007 Eaton Corporation. All rights reserved. INTRODUCTION. As more and more industries

More information

THE COMPACT LINE. Mobile power packs in convincing BAUER quality l/min 225 / 330 bar TOUGH RELIABLE WELL ESTABLISHED

THE COMPACT LINE. Mobile power packs in convincing BAUER quality l/min 225 / 330 bar TOUGH RELIABLE WELL ESTABLISHED THE COMPACT LINE Mobile power packs in convincing BAUER quality 100 140 l/min 225 / 330 bar TOUGH RELIABLE WELL ESTABLISHED COMPACT LINE mobile breathing air compressors for high demands Due to its legendary

More information

OXYGEN and SYSTEM OXY

OXYGEN and SYSTEM OXY OXYGEN and SYSTEM OXY Used to mix the treated liquid with air allowing a high degree of oxygen exchange Particularly indicated for an efficient oxigenation in waste water treatment plant as well as industrial

More information

icon i150 / i350 Installation / Operation Manual

icon i150 / i350 Installation / Operation Manual i150 Concentrator i350 Concentrator icon i150 / i350 Installation / Operation Manual www.iconcentrator.com What You Will Need to Install Your icon In order to install your icon you will have to consider

More information

24L AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: RANGER 7/240 PART NO: LS0913

24L AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: RANGER 7/240 PART NO: LS0913 24L AIR COMPRESSOR MODEL NO: RANGER 7/240 PART NO: 2242000 OPERATION & MAINTENANCE INSTRUCTIONS LS0913 INTRODUCTION Thank you for purchasing this CLARKE 24L Air Compressor. Please read this manual fully

More information

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS Annex 3, page 2 ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS The text of existing chapter 15 is replaced by the following: "1 Application This

More information

BOSS PULISCI PROVA IMPIANTI MEDIA

BOSS PULISCI PROVA IMPIANTI MEDIA BOSS PULISCI PROVA IMPIANTI MEDIA Pump for power flushing operations and removal of impurities, suitable for hydraulic, solar, floor systems and for cooling circuits of medium size. Suitable for buildings,

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S Page 1 of 13 1. DESCRIPTION The Viking 6 Model G-6000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler

More information

Fluid Dispensing Systems H O S E R E E L S H O S E S HOSE REELS

Fluid Dispensing Systems H O S E R E E L S H O S E S HOSE REELS Fluid Dispensing Systems H O S E R E E L S H O S E S HOSE REELS HOSE REELS SIGNATURE SERIES H O S E S R E E L S FEATURES & BENEFITS Eight position locking precision die cast latch mechanism, with secure

More information

market leading commercial and domestic ventilation with heat recovery Nilan VPM Active heat recovery and cooling (air/air)

market leading commercial and domestic ventilation with heat recovery Nilan VPM Active heat recovery and cooling (air/air) market leading commercial and domestic ventilation with heat recovery Nilan VPM 120-560 Active heat recovery and cooling (air/air) Nilan VPM 120-560 Industrial ventilation with heat recovery and cooling

More information

GEN20AD-GEN20AL-GEN18AN

GEN20AD-GEN20AL-GEN18AN AD-- Parts List 02-August-16 This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-ad--.pdf for the current revision. Standby Generators Table of Contents

More information

Budget Range Operators Handbook

Budget Range Operators Handbook Budget Range Operators Handbook BAMBI AIR COMPRESSORS LTD 152 Thimble Mill Lane Heartlands Birmingham B7 5HT United Kingdom Tel: 0121 322 2299 Fax: 0121 322 2297 Email: sales@bambi-air.co.uk www.bambi-air.co.uk

More information

INSTALLATION & OPERATING INSTRUCTIONS FOR THE DS300 BRAZING HEARTH FLAMEFAST (UK) LIMITED

INSTALLATION & OPERATING INSTRUCTIONS FOR THE DS300 BRAZING HEARTH FLAMEFAST (UK) LIMITED INSTALLATION & OPERATING INSTRUCTIONS FOR THE DS300 BRAZING HEARTH FLAMEFAST (UK) LIMITED Unit 2. Labtec Street. Swinton. Manchester M27 8SE Telephone 0161 793 9998. Fax 0161 793 0098 www.flamefast.co.uk.

More information

Squeegee Unit for MRS Multi-Recovery System

Squeegee Unit for MRS Multi-Recovery System En Operating Instructions Squeegee Unit for MRS Multi-Recovery System Translation of the original operating instructions Squeegee - MRS Table of Contents Safety Recommendations Technical Data - MRS Booth

More information

SEries 29 Hydrant valves installation, operation & maintenance manual

SEries 29 Hydrant valves installation, operation & maintenance manual Instruction for use Thank you for selecting an AVK product. With correct use, it will give long and reliable service. This manual has been prepared to assist you install, operate and maintain the valve

More information