Engineering Data RPM: 3000 HP: Serv. Factor: 1,0 KW:,37 Form Factor: 1,00 Amps: 20 KW2: Form Factor 2: FLA2: Volts: 24. Frame: 71D

Size: px
Start display at page:

Download "Engineering Data RPM: 3000 HP: Serv. Factor: 1,0 KW:,37 Form Factor: 1,00 Amps: 20 KW2: Form Factor 2: FLA2: Volts: 24. Frame: 71D"

Transcription

1 Product Features Catalog No: L085/O043/ Model: CI42D34FT7C Engineering Data RPM: 3000 HP: Serv. Factor: 1,0 KW:,37 Form Factor: 1,00 Amps: 20 KW2: Form Factor 2: FLA2: Volts: 24 Frame: 71D Max Amb: 40 Duty: S1 Type: L71-12 Insul Class: F3 Enclosure: IP54 Bearing OPE Protection: NOT Protector: Bearing PE: EFF: 72.2 Net Motor Wt: 23 LB Carton Label: IEC Torque: 10.5 LB-IN UL: yes CSA: yes CE: no Lubrication: Assembly: Mounting: SPECIAL Rotation: RECONN Winding: D47272 Ext. Diag1.: Ext. Diag2.: Group: 1 Shaft Dia.: 14 MM Packaging: Subgroup: A Paint: Test Card: 01 Cust Part No: MULTIPLE AB Code: Resistance:.045 Connection: Rework Status: RMS Amps RMS Amps: Peak: Peak@DegC: Constant TorqueSpeed Range: Rework TYPE: Explosion Proof Brake Motors Temp Op Code: FORCE: 0 Class: GROUP: VDC: 0 Class: GROUP: ADC: 0 Brake Coil C: 0 Performance Torque : CURRENT (amps): Efficiency (%): PowerFactor:

2

3 Product Features Catalog No: L085/O043/ Model: CI42D17FT7B Engineering Data RPM: 1800 HP: Serv. Factor: 1,0 KW:,37 Form Factor: 1,00 Amps: 20 KW2: Form Factor 2: FLA2: Volts: 24 Frame: 71D Max Amb: 40 Duty: S1 Type: N71-12 Insul Class: F3 Enclosure: IP54 Bearing OPE Protection: NOT Protector: Bearing PE: EFF: 76.9 Net Motor Wt: 23 LB Carton Label: IEC Torque: 17.5 LB-IN UL: yes CSA: yes CE: no Lubrication: Assembly: Mounting: SPECIAL Rotation: RECONN Winding: D47273 Ext. Diag1.: Ext. Diag2.: Group: 1 Shaft Dia.: 14 MM Packaging: Subgroup: A Paint: Test Card: 01 Cust Part No: MULTIPLE AB Code: Resistance:.07 Connection: Rework Status: RMS Amps RMS Amps: Peak: Peak@DegC: Constant TorqueSpeed Range: Rework TYPE: Explosion Proof Brake Motors Temp Op Code: FORCE: 0 Class: GROUP: VDC: 0 Class: GROUP: ADC: 0 Brake Coil C: 0 Performance Torque : CURRENT (amps): Efficiency (%): PowerFactor:

4

5

6

7

8

9

10

11

12

13 Product Features Catalog No: L085/O043/ Model: CI4D17FT6A Engineering Data RPM: 1800 HP: Serv. Factor: 1.0 KW:,75 Form Factor: 1,00 Amps: 39 KW2: Form Factor 2: FLA2: Volts: 24 Frame: 80D Max Amb: 40 Duty: S1 Type: Y80-14 Insul Class: F3 Enclosure: IP44 Bearing OPE Protection: NOT Protector: Bearing PE: EFF: 82.8 Net Motor Wt: 52 LB Carton Label: IEC Torque: 35,0 LB-IN UL: yes CSA: yes CE: no Lubrication: Assembly: Mounting: SPECIAL Rotation: RECONN Winding: D55251 Ext. Diag1.: Ext. Diag2.: Group: 1 Shaft Dia.: 19 MM Packaging: Subgroup: E Paint: Test Card: 02 Cust Part No: MULTIPLE AB Code: Resistance:.055 Connection: Rework Status: RMS Amps RMS Amps: Peak: Peak@DegC: Constant TorqueSpeed Range: Rework TYPE: Explosion Proof Brake Motors Temp Op Code: FORCE: 0 Class: GROUP: VDC: 0 Class: GROUP: ADC: 0 Brake Coil C: 0 Performance Torque : CURRENT (amps): Efficiency (%): PowerFactor:

14

15 Product Features Catalog No: L085/O043/ Model: CI4D34FT5A Engineering Data RPM: 3000 HP: Serv. Factor: 1,0 KW:,75 Form Factor: 1,00 Amps: 40 KW2: Form Factor 2: FLA2: Volts: 24 Frame: 80D Max Amb: 40 Duty: S1 Type: X80-14 Insul Class: F3 Enclosure: IP44 Bearing OPE Protection: NOT Protector: Bearing PE: EFF: 81.6 Torque: 21,0 LB-IN UL: yes CSA: yes CE: no Net Motor Wt: 33 LB Carton Label: IEC Lubrication: Assembly: Mounting: SPECIAL Rotation: RECONN Winding: D Ext. Diag1.: Ext. Diag2.: Group: 1 Shaft Dia.: 19 MM Packaging: Subgroup: A Paint: Test Card: 01 Cust Part No: MULTIPLE AB Code: Resistance:.025 Connection: Rework Status: RMS Amps RMS Amps: Peak: Peak@DegC: Constant TorqueSpeed Range: Rework TYPE: Explosion Proof Brake Motors Temp Op Code: FORCE: 0 Class: GROUP: VDC: 0 Class: GROUP: ADC: 0 Brake Coil C: 0 Performance Torque : CURRENT (amps): Efficiency (%): PowerFactor:

16

17 Product Features Catalog No: L085/O043/ Model: CI4D34FT6B Engineering Data RPM: 3000 HP: Serv. Factor: 1,0 KW: 1,1 Form Factor: 1,00 Amps: 65 KW2: Form Factor 2: FLA2: Volts: 24 Frame: 80D Max Amb: 40 Duty: S1 Type: WL80-14 Insul Class: F3 Enclosure: IP44 Bearing OPE Protection: NOT Protector: Bearing PE: EFF: 78.8 Torque: 31.5 LB-IN UL: yes CSA: yes CE: no Net Motor Wt: 33 LB Lubrication: Carton Label: IEC Assembly: Mounting: SPECIAL Rotation: CCWLE Winding: D Ext. Diag1.: Ext. Diag2.: Group: 1 Shaft Dia.: 19 MM Packaging: Subgroup: A Paint: Test Card: 01 Cust Part No: MULTIPLE AB Code: Resistance:.058 Connection: Rework Status: RMS Amps RMS Amps: Peak: Peak@DegC: Constant TorqueSpeed Range: Rework TYPE: Explosion Proof Brake Motors Temp Op Code: FORCE: 0 Class: GROUP: VDC: 0 Class: GROUP: ADC: 0 Brake Coil C: 0 Performance Torque : CURRENT (amps): Efficiency (%): PowerFactor:

18

19

Hazardous Duty Explosion Proof, Three Phase, Blue Chip Severe Duty

Hazardous Duty Explosion Proof, Three Phase, Blue Chip Severe Duty Applications: Hazardous Duty Explosion Proof, Three Phase Class I Groups C & D, Class II Groups F & G, Rigid Base installed in hazardous environments as defined by the motor's explosion proof class and

More information

Hazardous Duty Division 1 Explosion Proof Class I Only, Groups C (as noted), D

Hazardous Duty Division 1 Explosion Proof Class I Only, Groups C (as noted), D lass I Only, Groups (as noted), D Blue hip, EPAct Efficiency, Three Phase 10:1 Variable torque, 2:1 onstant torque 1.15 Service Factor lass F insulation Meets temperature code T2A All ast iron construction

More information

WELDING POSITIONER MODEL NO:

WELDING POSITIONER MODEL NO: WELDING POSITIONER WP-250 13-3/4 Diameter Table 0 to 5.5 RPM Rotation Speed Manual Tilt Adjustment 0 to 90 Tilting Angle Standard w/foot Control Switch Shipping Weight 113 lbs. Designed for rotation of

More information

VLT 2000 Series. How to size your VLT

VLT 2000 Series. How to size your VLT Selection of frequency converter Usually the size of frequency converter is chosen on the basis of the shaft output, as this may be the only value known. However, if the data are known for both the application,

More information

Meta-MEC Manual Motor Starters

Meta-MEC Manual Motor Starters www.lsis.biz Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 45 mm 70 mm 63AF 100AF 3 LS Meta-MEC Manual Motor Starters deliver more

More information

Motors for the Long Run! SB338. marathonelectric.com

Motors for the Long Run! SB338. marathonelectric.com Motors for the Long Run! SB338 A WORLD OF ENERGY SOLUTIONS marathonelectric.com 800.616.7077 Easy to do business with 24/7/365!!! ME business: Marathon Electric s new and improved ecommerce site, ME business,

More information

REULAND DIRECT ACTING MAGNETIC DISC BRAKE ONLY ONE MOVING PART SIMPLE / DIRECT ACTING / TROUBLE FREE OPERATION

REULAND DIRECT ACTING MAGNETIC DISC BRAKE ONLY ONE MOVING PART SIMPLE / DIRECT ACTING / TROUBLE FREE OPERATION REULAND DIRECT ACTING MAGNETIC DISC BRAKE ONLY ONE MOVING PART SIMPLE / DIRECT ACTING / TROUBLE FREE OPERATION THE WORLD S SECOND SIMPLEST BRAKE DESIGN Concept / Design / Reality SEVEN MAJOR PARTS, ONLY

More information

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18 The Bray Simple Set Max is a flanged pressure independent control (PIC) valve designed for a wide variety of hot water and chilled water control applications. The SSM Series combines high rangeability

More information

Glycol Systems. Engineering Manual. 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers

Glycol Systems. Engineering Manual. 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers Glycol Systems Engineering Manual 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers Stulz Air Technology Systems, Inc. Table of Contents Section - 1 Table

More information

DCS Series 1 kw, 1.2 kw, & 3 kw

DCS Series 1 kw, 1.2 kw, & 3 kw Established 1981 Advanced Test Equipment Rentals www.atecp.com 800-404-ATEC (2832) DCS Series 1 kw, 1.2 kw, & 3 kw DCS Applications The DCS Family is ideally suited f a wide range of applications requiring

More information

OPERATION, INSTALLATION, & MAINTENANCE MANUAL. for. Aircon Flex-air AN Airlocks

OPERATION, INSTALLATION, & MAINTENANCE MANUAL. for. Aircon Flex-air AN Airlocks OPERATION, INSTALLATION, & MAINTENANCE MANUAL for Aircon Flex-air AN Airlocks Aircon Corporation P.O. Box 80446 2873 Chelsea Avenue Memphis, TN 38108-0446 Telephone: (901) 452-0230 FAX: (901) 452-0750

More information

4 qwer 2/2 3/2 4/2. Intrinsically Safe. Air and Inert Gas Intrinsically Safe Valves Brass, or Stainless Steel Bodies 1/4" to 1" NPT SERIES.

4 qwer 2/2 3/2 4/2. Intrinsically Safe. Air and Inert Gas Intrinsically Safe Valves Brass, or Stainless Steel Bodies 1/4 to 1 NPT SERIES. qwer Air and Inert Gas Valves Brass, or Stainless Steel Bodies 1/" to 1" NPT Features Designed solely for installation in intrinsically safe areas, with properly approved and sized current and voltage-limiting

More information

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure General-purpose Limit Switch CSM_DA-_N_DS_E The Limit Switch with Better Seal, Shock Resistance, and Strength A double seal on the head, a complete gasket cover, and other features ensure a better seal

More information

Type MMV Medium Power Cable

Type MMV Medium Power Cable 7-05 Type MMV Medium Power Cable Single Conductor: 5kV 5kV, 00% & % Insulation Levels. Rated 90 C Multi-Conductor: 5kV 5kV, 00% & % Insulation Levels. Rated 90 C Conductors Soft annealed flexible stranded

More information

VERTICAL TURBINE PUMPS Right Angle Gears. Shaft Guarding for Horizontal Mounted Spicer Universal Joint Drive Shafts

VERTICAL TURBINE PUMPS Right Angle Gears. Shaft Guarding for Horizontal Mounted Spicer Universal Joint Drive Shafts Peerless Pump Company Indianapolis, IN 46207-7026 VERTICAL TURBINE PUMPS Right Angle Gears SECTION 110 Page 1 January 2, 2007 Shaft Guarding for Horizontal Mounted Spicer Universal Joint Drive Shafts A

More information

DESCRIPTION / REMARKS E40972 ROTATION (2).250 FLAG TYPE Q.C. TERMS. WITH INSUL. GRIP ON BROWN LEADS. LEADS SKINNED.750±.062

DESCRIPTION / REMARKS E40972 ROTATION (2).250 FLAG TYPE Q.C. TERMS. WITH INSUL. GRIP ON BROWN LEADS. LEADS SKINNED.750±.062 Dimensional Drawing MODEL REF CUSTOMER HP VOLTS AMPS HZ RPM ROTATION CUSTOMER PN DESCRIPTION / REMARKS K55HXRHM2147 E40972 DAYTON 1/6 208230 1.3 60 1075 C.CW. LEAD END REV BALL BEARING E40972 #16 GREEN

More information

PVQ 13 A2 R SE 1 S 20 C-11 D

PVQ 13 A2 R SE 1 S 20 C-11 D PVQ - Variable Displacement Piston Pump PVQ 13 A2 R SE 1 S 2 C-11 D 1 2 3 4 6 7 8 9 1 1 Model Series PVQ Inline Piston Pump Variable Volume Quiet Series 4 Rotation Viewed from shaft end R Right hand, standard

More information

Zelio Relays RSL Slim Interface Plug-In Relays

Zelio Relays RSL Slim Interface Plug-In Relays Zelio Relays RSL Slim Interface Plug-In Relays Catalog 8501CT0901 2009 Class 8501 CONTENTS Description............................................. Page Introduction.................................................3

More information

ACCESSORIES. Standard packing

ACCESSORIES. Standard packing ACCESSORIES HC RELAYS (Sockets and Terminal ) FEATURES. HC Relay Sockets In the table below, the suitable for each type of HC relay is indicated by a black dot. ) Plug-in type, type, and wrapping type

More information

OMS Technical Information. Versions OMS. Versions

OMS Technical Information. Versions OMS. Versions Versions Versions Mounting flange Shaft Port size European version US version Drain connection Check valve Main type designation Standard flange Cyl. 32 G 1/2 l Yes Yes Cyl. 1.25 in 7/8-14 UNF l Yes Yes

More information

AIR CONDITIONERS WA14**W SERIES

AIR CONDITIONERS WA14**W SERIES FORM NO. A66-225 REV. 3 AIR CONDITIONERS Features Outdoor air conditioner designed for ground level or rooftop installations. These units offer comfort and dependability for single, multi-family and light

More information

Orbital Motors Type OMP X and OMR X

Orbital Motors Type OMP X and OMR X Technical Information Orbital Motors Type OMP X and OMR X powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev January 218 Major revision. 21 February 217 First edition. 11 2

More information

PRODUCT SPECIFICATION

PRODUCT SPECIFICATION MINI-FIT SR. SERIES 1.0 SCOPE This specification covers the 10.00 mm / (.394 in.) centerline tin and gold plated connector series, single and dual row versions in wire to wire and wire to printed circuit

More information

ASM. Asynchronous Spindle Motors. SEM Limited Faraday Way Orpington, Kent BR5 3QT United Kingdom

ASM. Asynchronous Spindle Motors. SEM Limited Faraday Way Orpington, Kent BR5 3QT United Kingdom NE ASM Asynchronous Spindle Motors SEM Limited Faraday Way Orpington, Kent BR 3QT United Kingdom Tel: +44 ()189 8847 Fax: +44 ()189 884884 Email: sales@sem.co.uk Web: www.sem.co.uk Version 4 August 2 Asynchronous

More information

Glycol Systems. Engineering Manual. 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers

Glycol Systems. Engineering Manual. 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers Glycol Systems Engineering Manual 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers Stulz Table of Contents Section - 1 Table of Contents... 1-1 Glycol

More information

VSD03M DIRECTIONAL CONTROL VALVES

VSD03M DIRECTIONAL CONTROL VALVES NFPA SIZE D03 TYPICAL PERFORMANCE SPECIFICATIONS Performance is measured on a four-way circuit (full circuit). Performance may e reduced from that shown if a three-way circuit (half circuit) is used, i.e.

More information

DESIGN ENVELOPE 6800 G 1 DUTY PUMP

DESIGN ENVELOPE 6800 G 1 DUTY PUMP DESIGN ENVELOPE 68 G 1 DUTY PUMP AND 1 STANDBY, DOMESTIC WATER BOOSTER WIT STANDBY N122s N192s SUBMITTAL File No: 1.615 Date: june 27, 217 Supersedes: new Date: new Job: Representative: Engineer: Contractor:

More information

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO 97C COMPRESSOR KIT 12V PART NO. 00097 97C COMPRESSOR KIT 24V PART NO. 02497 98C COMPRESSOR KIT PART NO. 00098 97C 98C IMPORTANT: It is essential that you and any other operator of this product read and

More information

AIR CONDITIONERS WA14 SERIES

AIR CONDITIONERS WA14 SERIES FORM NO. A66-220 REV. 3 AIR CONDITIONERS Features Outdoor air conditioner designed for ground level or rooftop installations. These units offer comfort and dependability for single, multi-family and light

More information

Monitoring device NTS 30

Monitoring device NTS 30 P R O D U C T I N F O R M A T I O N Electronic level- and temperature monitoring device Monitoring device NTS 30 Contents Description Description... 2 Operating... 3 Design and electrical data... 4 Circuit

More information

All technical data may be changed MADE IN ITALY BY NARDI COMPRESSORI

All technical data may be changed MADE IN ITALY BY NARDI COMPRESSORI PACIFIC MX NITROX BREATHING AIR according to DIN EN 12021 MAX OXYGEN 40% DELIVERY l/min 600 m 3 h 36 PRESSURE BAR 225 PSI 3250 Quality system certified to iso 9001 BREATHING AIR is a product line that

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock: - Do not disassemble. Do not attempt repairs or modifications. Refer to qualified service agencies for all service and repairs.

More information

100C Air Compressor Kit

100C Air Compressor Kit 10010 100C Air Compressor (standard mounting bracket, CE Spec) 10014 100C Air Compressor (no leader hose or check valve, CE Spec) 10016 100C Air Compressor (with Omega Bracket, CE Spec) IMPORTANT: It is

More information

KSB Delta Compact Type Series Booklet

KSB Delta Compact Type Series Booklet Pressure Booster System KSB Delta Compact Type Series Booklet Legal information/copyright Type Series Booklet KSB Delta Compact All rights reserved. The contents provided herein must neither be distributed,

More information

OHIO GEAR REDUCERS DESIGN FEATURES

OHIO GEAR REDUCERS DESIGN FEATURES REDUCERS Cast Iron NEMA C Flange with machined fits for precision alignment for motor and bearings. Seal Guard on quill-input styles protects input seals from damage during motor installation. Oversized

More information

200 PSI COMPRESSORS - MODEL NUMBERS

200 PSI COMPRESSORS - MODEL NUMBERS 200 PSI COMPRESSORS - MODEL NUMBERS 380C AIR COMPRESSOR KIT PART NO. 38033 480C AIR COMPRESSOR KIT PART NO. 48043 380C 480C IMPORTANT: It is essential that you and any other operator of this product read

More information

(1) Warranty Certificate 01. (2) About the use of Traction Machine 03. (3) General Instructions 03. EMC Directive 03. Copy Right Low 03.

(1) Warranty Certificate 01. (2) About the use of Traction Machine 03. (3) General Instructions 03. EMC Directive 03. Copy Right Low 03. 01 (1) Warranty Certificate 01. (2) About the use of Traction Machine 03. (3) General Instructions 03. EMC Directive 03. Copy Right Low 03. Sign - Symbol - Interpretation & Meaning 04. (4) Technical Drawing

More information

stepper motor 2-phase hybrid stepper motor (bipolar) high protection class with plug or stranded wires optional with encoder / brake

stepper motor 2-phase hybrid stepper motor (bipolar) high protection class with plug or stranded wires optional with encoder / brake stepper motor 2-phase hybrid stepper motor (bipolar) high protection class with plug or stranded wires optional with / brake / 9 www.igus.de MOT-AN-S_EN_2070# part number (not configurable, only for illustration)

More information

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO 420C AIR COMPRESSOR KIT PART NO. 42042 460C AIR COMPRESSOR KIT PART NO. 46043 420C 460C IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this

More information

OMS, OMT and OMV Orbital Motors. Technical Information

OMS, OMT and OMV Orbital Motors. Technical Information , OMT and OMV Orbital Motors Technical Information , OMT and OMV A Wide Range of Orbital Motors Revision History Table of Revisions Date Page Changed Rev ED Dimensions changed EF A Wide Range of Orbital

More information

Z, Y, and X PURGE INDICATORS / CONTROLLERS

Z, Y, and X PURGE INDICATORS / CONTROLLERS PurgEx XXXXXX Z, Y, and X PURGE INDICATORS / CONTROLLERS PURGE / PRESSURIZATION PURGE / PRESSURIZATION XXXXX XXXXXXXXX 8626 SERIES Globally Certified Z,Y,X Purge Indicators / Controllers and Accessories

More information

KSB Delta Compact Type Series Booklet

KSB Delta Compact Type Series Booklet Pressure Booster System KSB Delta Compact Type Series Booklet Legal information/copyright Type Series Booklet KSB Delta Compact All rights reserved. The contents provided herein must neither be distributed,

More information

North American Pressure Switches

North American Pressure Switches Combustion North American Pressure Switches Bulletin 8757 Pressure switches are used with Automatic Shutoff Valves or Solenoid Valves to interrupt fuel flow in the event of fuel or air failure. They are

More information

Orbital Motors Type OMP, OMR and OMH. Technical Information

Orbital Motors Type OMP, OMR and OMH. Technical Information Orbital Motors Type OMP, OMR and OMH Technical Information OMP, OMR and OMH Contents Revision View Date Page Changed Revision Mar 26 Small updates B Jun 27 all Major revision with new lit-number (minus

More information

INSTALLATION AND MAINTENANCE MANUAL

INSTALLATION AND MAINTENANCE MANUAL INSTALL.06 INSTALLATION AND MAINTENANCE MANUAL WORLDWIDE ELECTRIC THREE-PHASE MOTORS WorldWide Electric Corporation Phone: 1-800-808-2131 Ext. 3 Fax: 1-800-711-1616fffffgff Website: www.worldwideelectric.net

More information

Further technical information is available on

Further technical information is available on 1 of 5 Manufacture address : Bartec Technor AS Dusavikveien 39 4007 Stavanger Norway Further technical information is available on www.bartec-technor.no Note on instructions When working in hazardous areas,

More information

ENGINEERING DATA. Engineering Data

ENGINEERING DATA. Engineering Data ENGINEERING DATA Engeerg Data 599 Average Depth 3.5 ft. ESTIMATING TOTAL GALLONS IN A POOL OR SPA Length 24 ft. Dia. Width Depth (deep) Depth (shallow) Radius 2 x 3.14 x A.D. x 7.5 = Gallons 12 x 12 x

More information

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications Replaces: 04.95 Dual displacement motor 10VM Plug-in dual displacement motor 10VE for open and closed circuit applications Size 28-60 Series 5 Nominal pressure 280 bar Peak pressure 350 bar 10VM Contents

More information

COMMERCIAL LOW PROFILE 8 Electric Heated Air Curtain Data Sheet

COMMERCIAL LOW PROFILE 8 Electric Heated Air Curtain Data Sheet For Door Heights To 8 (environmental separation) COMMERCIAL LOW PROFILE 8 Data Sheet STANDARD CONSTRUCTION 8 1/2 high x 13 1/2 deep 1/5 hp two speed motor(s) Factory installed fan speed/heat switch White

More information

PRESSURE SWITCHES Bulletin 8757

PRESSURE SWITCHES Bulletin 8757 PRESSURE SWITCHES Bulletin 8757 September 2013 Pressure switches are used with Automatic Shutoff Valves or solenoid valves to interrupt fuel fl ow in the event of fuel or air failure. They are also used

More information

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only) 42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) 42047 Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only) 45052 Constant Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor

More information

BGA158 Series CE Approved Class A Shutoff Gas Valve

BGA158 Series CE Approved Class A Shutoff Gas Valve Installation Instructions BGA158 Issue Date August 24, 2011 BGA158 Series CE Approved Class A Shutoff Gas Valve Applications The BGA158 Series shutoff gas valve is an electrically operated gas valve that

More information

P/N: IND-DP Industrial Drum Pumps

P/N: IND-DP Industrial Drum Pumps P/N: IND-DP-0613 Industrial Drum Pumps Multi-Certified Industrial SAFETY Solutions SAFETY: As a leading pump manufacturer, Standard is known for our commitment to product quality and SAFETY serving the

More information

Meta-MEC Manual Motor Starters

Meta-MEC Manual Motor Starters Leader in Electrics & Automation Meta-MEC Manual Motor Starters Electric Equipment LG Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 45 mm 70 mm 63AF 100AF 3 LG Meta-MEC

More information

Electro-Pneumatic Converter YT-940 SERIES

Electro-Pneumatic Converter YT-940 SERIES Electro-Pneumatic Converter YT-940 SERIES PRODUCT MANUAL VERSION 1.00 Contents 1. Introduction 3 1.1 General information for the users. 3 1.2 Manufacturer Warranty 3 1.3 Explosion Proof Warning. 4 2. Product

More information

Operator Interface Enclosures

Operator Interface Enclosures ` www.hammfg.com s - NEMA 12, 13 Tara Plus 600 (135.2 lbs) 500 (112.4 lbs) Weight in Newtons 400 (90.1 lbs) 300 (67.4 lbs) 200 (45.1 lbs) 100 (22.5 lbs) 0.50 (1.6 ft) 1.00 (3.28 ft) Extension in Meters

More information

Position switches FP series

Position switches FP series A Position switches FP series Selection diagram 0 08 8 9 0 0 0 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fiber glass rod gasket sphere sphere adjustable lever safety adjustable lever

More information

BGA158 Series CE Approved Class B Shutoff Gas Valve

BGA158 Series CE Approved Class B Shutoff Gas Valve Installation Instructions BGA158 Issue Date March 22, 2016 BGA158 Series CE Approved Class B Shutoff Gas Valve Applications The BGA158 Series shutoff gas valve is an electrically operated shutoff valve

More information

Differential Pressure Control Types MP 54, MP 55 and MP 55A

Differential Pressure Control Types MP 54, MP 55 and MP 55A MAKING MODERN LIVING POSSIBLE Data sheet Differential Pressure Control Types MP 54, MP 55 and MP 55A MP 54 and MP 55 oil differential pressure controls are used as safety switches to protect refrigeration

More information

G SERIES METRIC MACHINE SCREW ACTUATOR

G SERIES METRIC MACHINE SCREW ACTUATOR G SERIES METRIC MACHINE SCREW ACTUATOR kn to 0kN Duff-Norton metric actuators are manufactured to the same high quality standards and include all the same features and benefits as the standard line of

More information

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO 400H HARDMOUNT AIR COMPRESSOR KIT PART NO. 40042 450H HARDMOUNT AIR COMPRESSOR KIT PART NO. 45042 400H 450H IMPORTANT: It is essential that you and any other operator of this product read and understand

More information

Expert Hydrostatic Level Transmitters

Expert Hydrostatic Level Transmitters Expert Hydrostatic s General Features MJK Expert hydrostatic level transmitters are designed for level measurement by submerging the transmitter in open channels, drains and tanks. Expert hydrostatic level

More information

Réf GB /d ALTERNATORS LSA Pole - Three phase. Electrical and mechanical data

Réf GB /d ALTERNATORS LSA Pole - Three phase. Electrical and mechanical data Réf. 264 GB - 2.33/d - 9. 3 2 1 1 ALTERNATORS LSA 42.2-4 Pole - Three phase Electrical and mechanical data TYPICAL DATA ALTERNATORS Hz - 1 r.p.m. Insulation class H Excitation system Shunt A R E P Winding

More information

Differential pressure controls, Type MP 54, 55 and 55A

Differential pressure controls, Type MP 54, 55 and 55A MAKING MODERN LIVING POSSIBLE Technical brochure Differential pressure controls, Type MP 54, 55 and 55A MP 54 and oil pressure controls are used as safety switches to protect refrigeration compressors

More information

Miniature controls. Contactors. Overload relays. Starters. Control relays

Miniature controls. Contactors. Overload relays. Starters. Control relays Contactors Overload relays Starters Control relays Description General features Wiring terminations available include plugon connectors, wire pins for PC board mounting and solder connections Low power

More information

W01 Rolled Steel Fractional Horsepower Motor

W01 Rolled Steel Fractional Horsepower Motor Motors Automation Energy Transmission & Distribution Coatings Fractional Horsepower Motor Technical Catalogue NEMA Market The new generation of WEG general purpose steel motors. The motors of the line

More information

F series Foot Switches

F series Foot Switches F series Foot Switches ITC presents a complete line of foot switches from Bernstein, designed to respond to the most stringent requirements for machine control and safety applications. The F series includes

More information

RELAY PRODUCT GUIDE CONTENTS

RELAY PRODUCT GUIDE CONTENTS RELAY PRODUCT GUIDE CONTENTS 1.0 ABOUT FUJITSU COMPONENTS 1.1 Who we are Page 2 2.0 PRODUCT LINE-UP 2.1 Automotive relays Page 3 2.2 Power relays Page 8 2.3 Signal relays Page 16 2.4 High frequency relays

More information

HYDRAULIC MOTORS MTM APPLICATION OPTIONS CONTENTS EXCELLENCE GENERAL

HYDRAULIC MOTORS MTM APPLICATION OPTIONS CONTENTS EXCELLENCE GENERAL HYDRAULIC OORS APPLICAION» Skid Steer Loaders» etal working machines» renchers» Augers» Agricultural machines» Road building machines» Special vehicles» ine machines» Woodworking and sawmill machinery»

More information

6000SLX HYDRAULIC CRAWLER CRANE

6000SLX HYDRAULIC CRAWLER CRANE HYDRAULIC CRAWLER CRANE HYDRAULIC CRAWLER CRANE Contents Specifications 3-4 Symbols 4 Outline Winch Assingment 5 Dimensions & Main Specifications : Liftcrane 6 Dimensions & Main Specifications : Luffing

More information

THE DISECTION of the SUBMERSIBLE MOTOR and PUMP. Deepwell Submersibles

THE DISECTION of the SUBMERSIBLE MOTOR and PUMP. Deepwell Submersibles THE DISECTION of the SUBMERSIBLE MOTOR and PUMP THE DISECTION of the SUBMERSIBLE MOTOR and PUMP Presented by: Ken Adams Project Engineer - Submersibles History: Twenty Six Years as Flowserve Design Engineer,

More information

MODEL NUMBER: P PORTABLE COMPRESSOR

MODEL NUMBER: P PORTABLE COMPRESSOR MODEL NUMBER: 44043-440P PORTABLE COMPRESSOR IMPORTANT: It is essential that you and any other operator of the product read and understand the contents of this manual before installing and using this product.

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 10 mm flush Shielded PUR cable for oil and gas sector Accessories BF 30 Mounting flange, 30 mm Technical Data specifications Switching function Normally closed (NC) Output type

More information

E.2 Series. High efficiency circulator. Technical overview

E.2 Series. High efficiency circulator. Technical overview E.2 Series High efficiency Technical File No:.165 Date: june 05, 2017 Supersedes:.165 Date: october 08, 2015 contents Motor data 4 Technical data 4 Materials of construction 4 Dimensions and weights 5

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 15 mm non-flush Stainless steel housing Accessories BF 30 Mounting flange, 30 mm Technical Data specifications Switching element function NAMUR, NC Rated operating

More information

Models EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations

Models EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations Models EXN and OLG Certified. Not Modified. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations General Description Industrial Climate Engineering s (ICE) EXN and OLG pressurization

More information

A28 Series Two-Stage Temperature Controls with NEMA 1 Enclosure

A28 Series Two-Stage Temperature Controls with NEMA 1 Enclosure Master Catalog 125 Temperature Controls Section A Product Bulletin A28 Issue Date 0618 A28 Series Two-Stage Temperature Controls with NEMA 1 Enclosure Application These two-stage controls are designed

More information

Electric expansion valves Types AKV 10, AKV 15 and AKV 20

Electric expansion valves Types AKV 10, AKV 15 and AKV 20 Data sheet Electric expansion valves Types AKV 10, AKV 15 and AKV 20 AKV are electrically operated expansion valves designed for refrigerating plants. The AKV valves are normally controlled by a controller

More information

Fixed Displacement Plug-In Motor A2FE

Fixed Displacement Plug-In Motor A2FE www.phphyds.com Series 6, axial tapered piston, bent axis design for mounting in mechanical gearboxes Sizes 28...355 Nom. Pressure up to 400 bar Peak Pressure up to 450 bar he fixed displacement plug-in

More information

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO 250C-IG COMPRESSOR KIT 12V PART NO. 25050 250C-IG COMPRESSOR KIT 24V PART NO. 25058 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual

More information

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO 250C-IG COMPRESSOR KIT 12V PART NO. 25050 250C-IG COMPRESSOR KIT 24V PART NO. 25058 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual

More information

Liquid ring vacuum pumps single-stage

Liquid ring vacuum pumps single-stage Liquid ring vacuum pumps single-stage LPH 40106, LPH 40411, LPH 40516 Pressure range: Suction volume flow: 150 to 1013 mbar 50 to 270 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring vacuum pumps are displacement

More information

Pressure transmitters EMP 2

Pressure transmitters EMP 2 Data sheet Pressure transmitters EMP 2 The high accuracy pressure transmitter EMP 2 is designed for monitoring and control in marine and industial applications and offers a reliable pressure measurement,

More information

OMS Technical Information Technical data

OMS Technical Information Technical data Technical data TECHNICAL DATA FOR OMS Type OMS OMS OMS OMS OMS OMS OMS OMS OMS OMSW OMSW OMSW OMSW OMSW OMSW OMSW OMSW OMSW OMSS OMSS OMSS OMSS OMSS OMSS OMSS OMSS OMSS Motor size 80 100 125 160 200 250

More information

Diaphragm Vacuum Pumps and Compressors with Group C & D Explosion-Proof Motors Types: UN026, UN726, UN035, UN860

Diaphragm Vacuum Pumps and Compressors with Group C & D Explosion-Proof Motors Types: UN026, UN726, UN035, UN860 PROCESS Diaphragm Vacuum Pumps and Compressors with Group C & D Explosion-Proof Motors Types: UN026, UN726, UN035, UN860 Single & Twin-Head Designs OEM Installation Models UN860FTI EX UN726.3STI EX UN726.3FTI

More information

UHF/Mini-UHF Coaxial Connectors

UHF/Mini-UHF Coaxial Connectors UHF/MiniUHF Coaxial Connectors The Amphenol UHF/MINIUHF connectors are popular and economical, used when impedance mating is not required. General purpose units are designed to operate satisfactorily op

More information

MICRO SWITCH 914CE Series

MICRO SWITCH 914CE Series MICRO SWITCH 914CE Series Compact Limit Switch DESCRIION ll MICRO SWITCH 914CE series compact enclosed switches incorporate fluorocarbon diaphragm sealing to provide reliable protection, meeting NEM 1,

More information

General Purpose Three Phase Open Dripproof (ODP) NEMA Premium Efficient IE3

General Purpose Three Phase Open Dripproof (ODP) NEMA Premium Efficient IE3 General Purpose Three Phase Open Dripproof (ODP) Premium Efficient IE3 GENERAL APPLICATIONS: For pumps, fans, compressors, material handling, and other general purpose applications where contaminants are

More information

TABLE OF CONTENTS 2 TALAS DRYER 4 TALAS MEASURER 7 TALAS PORTABLE DRYER 9 TALAS LEAKER 11 TALAS STARTER 14 TALAS AUXILIARY 17 APPENDICES

TABLE OF CONTENTS 2 TALAS DRYER 4 TALAS MEASURER 7 TALAS PORTABLE DRYER 9 TALAS LEAKER 11 TALAS STARTER 14 TALAS AUXILIARY 17 APPENDICES TABLE OF CONTENTS 2 TALAS DRYER 4 TALAS MEASURER 7 TALAS PORTABLE DRYER 9 TALAS LEAKER 11 TALAS STARTER 14 TALAS AUXILIARY 17 APPENDICES ALL PICTURES SHOWN ARE FOR REFERENCE ONLY ACTUAL PRODUCT MAY VARY

More information

PVV Open Loop Pumps. Bulletin E

PVV Open Loop Pumps. Bulletin E PVV Open Loop Pumps Bulletin 47028-E Table of Contents Table of Contents Performance Assurance page 3 Features and Benefits 4-5 Specifications 6 Controls Single Pressure Compensator 7 Single Pressure Compensator

More information

Dual Solenoid Gas Valve Installation

Dual Solenoid Gas Valve Installation Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing or servicing FLYNN Gas Products. Carefully follow all instructions in this bulletin and all instructions

More information

NO: REL-149 PRODUCT: G8P Series PCB Power Relay DATE: November 2014 TYPE: Discontinuation Notice

NO: REL-149 PRODUCT: G8P Series PCB Power Relay DATE: November 2014 TYPE: Discontinuation Notice NO: REL-149 PRODUCT: PCB Power Relay DATE: November 2014 TYPE: Discontinuation Notice G8P PCB Power Relays to be DISCONTINUED April 30, 2015 Due to a diminishing global demand for the G8P series PCB Power

More information

Wildcat LB Winch Kit. Operator s Manual Installation Instructions Replacement Parts List. With Wireless Control System.

Wildcat LB Winch Kit. Operator s Manual Installation Instructions Replacement Parts List. With Wireless Control System. p/n 2259-560 Wildcat 4000 LB Winch Kit With Wireless Control System Operator s Manual Installation Instructions Replacement Parts List 2012 Arctic Cat Inc. Trademarks of Arctic Cat Inc. Thief River Falls,

More information

APPLICATION. Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries

APPLICATION. Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries HYDRAULIC APPLICATION Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries Special vehicles Plastic and rubber machinery etc. CONTENTS Specification

More information

Design Guide /01. ThermAir Burners TA Series version 1.10

Design Guide /01. ThermAir Burners TA Series version 1.10 Design Guide 114 10/01 ThermAir Burners TA Series version 1.10 COPYRIGHT DISCLAIMER NOTICE LIABILITY AND WARRANTY Copyright I998 by Eclipse Combustion, Inc. All rights reserved worldwide. This publication

More information

Introduction INDEX. INTRODUCTION HSE

Introduction INDEX.  INTRODUCTION HSE Introduction INDEX SECTION PAGE INTRODUCTION ORDERING CODE GLOSSARY MOTOR OPTION TECHNICAL SE SE3 / SE5 SE7 / S7 SE9 / S9 SE12 / S12 SE14 / S14 SE14-2 / S14-2 SE17 / S17 SE17-2 / S17-2 SE21 / S21 SE21-2

More information

Differential pressure switch MP 54, MP 55 and MP 55A

Differential pressure switch MP 54, MP 55 and MP 55A Data sheet Differential pressure switch MP 54, MP 55 and MP 55A MP 54 and MP 55 oil differential pressure switches are used as safety switches to protect refrigeration compressors against low lubricating

More information

Models EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations

Models EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations Models EXN and OLG Certified. Not Modified. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations General Description Industrial Climate Engineering s (ICE) EXN and OLG pressurization

More information

Equipment Accuracy / Selection

Equipment Accuracy / Selection Revision 5.0: Included the PPP program for clarification. Revision 6.0: Update references for CTL PDSH 251B to CTL DSH 251E" Added leakage current tolerances for values above 5KHz For Client Labs Purpose

More information

Variable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design

Variable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design Brueninghaus Hydromatik Series 1, for open circuits Axial piston - swashplate design, Back to back - design RE 93100/02.97 Sizes 60...260 Nominal Pressure up to 350 bar Peak Pressure up to 400 bar Preliminary

More information