24 AWG Nano M8 Single Ended and Double Ended Assemblies
|
|
- Isaac Robinson
- 6 years ago
- Views:
Transcription
1 24 AWG M8 Single Ended and Double Ended Abrasion Chemicals Flexing UL Listed CSA IP68 Rated RoHS Compliant 300 V Operating Temperature Range -30 C to 90 C Current Rating: 4 Amps Cord sets made with Trex-Onics 24 AWG cord designed for high cycle, constant motion applications and provides excellent defense against impact, cutting, abrasion, oil and chemicals. M8 Cordsets are molded so there is a 100% bond between the head and cord and are available with either a snap-lock or threaded coupling system choose whichever would be best suited for your application " Ref. (8mm) STRAIGHT FeMALE Snap Lock 1.305" Ref. (33mm) 0.328" Ref. (8mm) STRAIGHT MALE Snap Lock 1.160" Ref. (30mm) STRAIGHT FeMALE Threaded Coupling 0.390" Ref. (10mm) 1.380" Ref. (33mm) STRAIGHT MALE Threaded Coupling 0.390" Ref. (10mm) 1.575" Ref. (40mm) 90 FeMALE Threaded Coupling M8 x 1 Thread 90 FeMALE Snap Lock 1.133" Ref. (29mm) 1.133" Ref. (29mm) 0.770" Ref. (20mm) 0.705" Ref. (18mm) M8 x 1 Thread Features & Benefits 0.390" Ref. (10mm) 1. CORD SETS MADE WITH TREX-ONICS 24 AWG NANO CORD Designed for high cycle, constant motion applications. Provides excellent defense against impact, cutting, abrasion, oil and chemicals. 2. SPECIALLY COMPOUNDED NYLON INSERT Compatible with all industry standards for nano applications. Provides a superior seal against fluid and dust penetration " Ref. (8mm) 3. CONTACT PINS/SLEEVES ARE COPPER ALLOY AND GOLD PLATED Ensures electrical integrity in low voltage applications. Resists corrosion. 4. SNAP-LOCK OR THREADED COUPLING SYSTEMS Select configurations best suited for your applications. 5. ALL MOLDED DESIGN Ensures a 100% bond between head and cord. Eliminates glues and bonding materials that break down and leak over time, resulting in loss of signal and continuity. DIN Extension Cords Applications Bar Code Readers Computer Interfaces Digital Remote Controls Encoders or Resolvers Heat Pressure & Flow Meters Instrumentation I/O (input/output) Devices Load Cell Monitors Programmable Controllers Programmable Limit Switches Proximity Switches Robotics Servo Motors Sensors and Relays Solenoid Valves Tachometers Telecommunications Torque-Tool Monitoring Equipment X-Ray Monitors Variable Speed Motors Key Characteristics Snap Lock Configuration IP68 Rated Threaded Coupling Configuration IP68 Rated Nickel Plated Brass Coupling Nut Gold Plated Copper Alloy Pins 1 to 6 Meter Standard Lengths 300 V Rated & 4 Amp Rated 205
2 Cord sets & CONNECTOR ASSEMBLIES / nano quick-connects 24 AWG M8 Single Ended and Double Ended (Continued) DIN DC nano cable part no. Size Stranding Nominal o.d. (IN) Color code /3 7/ Brown, Black, Blue /4 7/ Brown, White, Black, Blue straight Female single ended Snap Lock CB13C33M001 3 Pole Single Ended Straight Female Snap CB13C33M002 3 Pole Single Ended Straight Female Snap CB13C33M004 3 Pole Single Ended Straight Female Snap CB13C33M005 3 Pole Single Ended Straight Female Snap CB13C33M006 3 Pole Single Ended Straight Female Snap CB14C34M001 4 Pole Single Ended Straight Female Snap CB14C34M002 4 Pole Single Ended Straight Female Snap CB14C34M004 4 Pole Single Ended Straight Female Snap CB14C34M005 4 Pole Single Ended Straight Female Snap CB14C34M006 4 Pole Single Ended Straight Female Snap straight male single ended Snap Lock CB13A33M001 3 Pole Single Ended Straight Male Snap CB13A33M002 3 Pole Single Ended Straight Male Snap CB13A33M004 3 Pole Single Ended Straight Male Snap CB13A33M005 3 Pole Single Ended Straight Male Snap CB13A33M006 3 Pole Single Ended Straight Male Snap CB14A34M001 4 Pole Single Ended Straight Male Snap CB14A34M002 4 Pole Single Ended Straight Male Snap CB14A34M004 4 Pole Single Ended Straight Male Snap CB14A34M005 4 Pole Single Ended Straight Male Snap CB14A34M006 4 Pole Single Ended Straight Male Snap straight Female single ended ThreadeD Coupling Extension Cords CA13C33M001 3 Pole Single Ended Straight Female Threaded CA13C33M002 3 Pole Single Ended Straight Female Threaded CA13C33M004 3 Pole Single Ended Straight Female Threaded CA13C33M005 3 Pole Single Ended Straight Female Threaded CA13C33M006 3 Pole Single Ended Straight Female Threaded CA14C34M001 4 Pole Single Ended Straight Female Threaded CA14C34M002 4 Pole Single Ended Straight Female Threaded CA14C34M004 4 Pole Single Ended Straight Female Threaded CA14C34M005 4 Pole Single Ended Straight Female Threaded CA14C34M006 4 Pole Single Ended Straight Female Threaded TPC Wire & Cable Corp. USA Canada Mexico
3 24 AWG M8 Single Ended and Double Ended (Continued) straight male single ended ThreadeD Coupling CA13A33M001 3 Pole Single Ended Straight Male Threaded CA13A33M002 3 Pole Single Ended Straight Male Threaded CA13A33M004 3 Pole Single Ended Straight Male Threaded CA13A33M005 3 Pole Single Ended Straight Male Threaded CA13A33M006 3 Pole Single Ended Straight Male Threaded CA14A34M001 4 Pole Single Ended Straight Male Threaded CA14A34M002 4 Pole Single Ended Straight Male Threaded CA14A34M004 4 Pole Single Ended Straight Male Threaded CA14A34M005 4 Pole Single Ended Straight Male Threaded CA14A34M006 4 Pole Single Ended Straight Male Threaded FEmale single ended ThreadeD Coupling CA13D33M001 3 Pole Single Ended 90 Female Threaded CA13D33M002 3 Pole Single Ended 90 Female Threaded CA13D33M004 3 Pole Single Ended 90 Female Threaded CA13D33M005 3 Pole Single Ended 90 Female Threaded CA13D33M006 3 Pole Single Ended 90 Female Threaded CA14D34M001 4 Pole Single Ended 90 Female Threaded CA14D34M002 4 Pole Single Ended 90 Female Threaded CA14D34M004 4 Pole Single Ended 90 Female Threaded CA14D34M005 4 Pole Single Ended 90 Female Threaded CA14D34M006 4 Pole Single Ended 90 Female Threaded straight female / straight female double ended threaded coupling CA23M33M001 3 Pole Double Ended Straight F/F Threaded CA23M33M002 3 Pole Double Ended Straight F/F Threaded CA23M33M004 3 Pole Double Ended Straight F/F Threaded CA23M33M005 3 Pole Double Ended Straight F/F Threaded CA23M33M006 3 Pole Double Ended Straight F/F Threaded CA24M34M001 4 Pole Double Ended Straight F/F Threaded CA24M34M002 4 Pole Double Ended Straight F/F Threaded CA24M34M004 4 Pole Double Ended Straight F/F Threaded CA24M34M005 4 Pole Double Ended Straight F/F Threaded CA24M34M006 4 Pole Double Ended Straight F/F Threaded DIN Extension Cords 207
4 Cord sets & CONNECTOR ASSEMBLIES / nano quick-connects 24 AWG M8 Single Ended and Double Ended (Continued) straight female / straight male double ended threaded coupling CA23E33M001 3 Pole Double Ended Straight F/M Threaded CA23E33M002 3 Pole Double Ended Straight F/M Threaded CA23E33M004 3 Pole Double Ended Straight F/M Threaded CA23E33M005 3 Pole Double Ended Straight F/M Threaded CA23E33M006 3 Pole Double Ended Straight F/M Threaded CA24E34M001 4 Pole Double Ended Straight F/M Threaded CA24E34M002 4 Pole Double Ended Straight F/M Threaded CA24E34M004 4 Pole Double Ended Straight F/M Threaded CA24E34M005 4 Pole Double Ended Straight F/M Threaded CA24E34M006 4 Pole Double Ended Straight F/M Threaded straight female / straight male double ended snap lock CB23E33M001 3 Pole Double Ended Straight F/M Snap CB23E33M002 3 Pole Double Ended Straight F/M Snap CB23E33M004 3 Pole Double Ended Straight F/M Snap CB23E33M005 3 Pole Double Ended Straight F/M Snap CB23E33M006 3 Pole Double Ended Straight F/M Snap CB24E34M001 4 Pole Double Ended Straight F/M Snap CB24E34M002 4 Pole Double Ended Straight F/M Snap CB24E34M004 4 Pole Double Ended Straight F/M Snap CB24E34M005 4 Pole Double Ended Straight F/M Snap CB24E34M006 4 Pole Double Ended Straight F/M Snap DIN Extension Cords straight male / straight male double ended threaded coupling CA23J33M001 3 Pole Double Ended Straight M/M Threaded CA23J33M002 3 Pole Double Ended Straight M/M Threaded CA23J33M004 3 Pole Double Ended Straight M/M Threaded CA23J33M005 3 Pole Double Ended Straight M/M Threaded CA23J33M006 3 Pole Double Ended Straight M/M Threaded CA24J34M001 4 Pole Double Ended Straight M/M Threaded CA24J34M002 4 Pole Double Ended Straight M/M Threaded CA24J34M004 4 Pole Double Ended Straight M/M Threaded CA24J34M005 4 Pole Double Ended Straight M/M Threaded CA24J34M006 4 Pole Double Ended Straight M/M Threaded straight female / 90 female double ended threaded coupling CA23N33M001 3 Pole Double Ended Straight F/90 F Threaded CA23N33M002 3 Pole Double Ended Straight F/90 F Threaded CA23N33M004 3 Pole Double Ended Straight F/90 F Threaded CA23N33M005 3 Pole Double Ended Straight F/90 F Threaded CA23N33M006 3 Pole Double Ended Straight F/90 F Threaded CA24N34M001 4 Pole Double Ended Straight F/90 F Threaded CA24N34M002 4 Pole Double Ended Straight F/90 F Threaded CA24N34M004 4 Pole Double Ended Straight F/90 F Threaded CA24N34M005 4 Pole Double Ended Straight F/90 F Threaded CA24N34M006 4 Pole Double Ended Straight F/90 F Threaded TPC Wire & Cable Corp. USA Canada Mexico
5 24 AWG M8 Single Ended and Double Ended (Continued) straight male / 90 female double ended threaded coupling CA23F33M001 3 Pole Double Ended Straight M/90 F Threaded CA23F33M002 3 Pole Double Ended Straight M/90 F Threaded CA23F33M004 3 Pole Double Ended Straight M/90 F Threaded CA23F33M005 3 Pole Double Ended Straight M/90 F Threaded CA23F33M006 3 Pole Double Ended Straight M/90 F Threaded CA24F34M001 4 Pole Double Ended Straight M/90 F Threaded CA24F34M002 4 Pole Double Ended Straight M/90 F Threaded CA24F34M004 4 Pole Double Ended Straight M/90 F Threaded CA24F34M005 4 Pole Double Ended Straight M/90 F Threaded CA24F34M006 4 Pole Double Ended Straight M/90 F Threaded female / 90 female double ended threaded coupling CA23P33M001 3 Pole Double Ended 90 F/90 F Threaded CA23P33M002 3 Pole Double Ended 90 F/90 F Threaded CA23P33M004 3 Pole Double Ended 90 F/90 F Threaded CA23P33M005 3 Pole Double Ended 90 F/90 F Threaded CA23P33M006 3 Pole Double Ended 90 F/90 F Threaded CA24P34M001 4 Pole Double Ended 90 F/90 F Threaded CA24P34M002 4 Pole Double Ended 90 F/90 F Threaded CA24P34M004 4 Pole Double Ended 90 F/90 F Threaded CA24P34M005 4 Pole Double Ended 90 F/90 F Threaded CA24P34M006 4 Pole Double Ended 90 F/90 F Threaded female / 90 female double ended snap lock part no. description cord length (ft.) cord length (m.) CB23P33M001 3 Pole Double Ended 90 F/90 F Snap CB23P33M002 3 Pole Double Ended 90 F/90 F Snap CB23P33M004 3 Pole Double Ended 90 F/90 F Snap CB23P33M005 3 Pole Double Ended 90 F/90 F Snap CB23P33M006 3 Pole Double Ended 90 F/90 F Snap CB24P34M001 4 Pole Double Ended 90 F/90 F Snap CB24P34M002 4 Pole Double Ended 90 F/90 F Snap CB24P34M004 4 Pole Double Ended 90 F/90 F Snap CB24P34M005 4 Pole Double Ended 90 F/90 F Snap CB24P34M006 4 Pole Double Ended 90 F/90 F Snap DIN Extension Cords straight male / 90 female double ended snap lock CB23F33M001 3 Pole Double Ended Straight M/90 F Snap CB23F33M002 3 Pole Double Ended Straight M/90 F Snap CB23F33M004 3 Pole Double Ended Straight M/90 F Snap CB23F33M005 3 Pole Double Ended Straight M/90 F Snap CB23F33M006 3 Pole Double Ended Straight M/90 F Snap CB24F34M001 4 Pole Double Ended Straight M/90 F Snap CB24F34M002 4 Pole Double Ended Straight M/90 F Snap CB24F34M004 4 Pole Double Ended Straight M/90 F Snap CB24F34M005 4 Pole Double Ended Straight M/90 F Snap CB24F34M006 4 Pole Double Ended Straight M/90 F Snap
Flow Sensors & Hydrometers Specification Sheet
Baseline Flow s and Hydrometers Baseline s smart flow sensors and hydrometers are two-wire ready flow measurement and control devices that are pre-programmed with the correct K and Offset values. In addition,
More informationEPIC Rectangular Connector Inserts. HBE Series. Technical Data Number of Contacts:
HBE Series HBE series inserts provide reliable termination and performance in the vast majority of medium power and control applications. Methods of termination include screw, crimp, and spring cage clamp.
More informationL3 Pressure and Level transmitter
SENSORS FOR AND BIOPHARMA. Product Information L3 L3 Pressure and Level transmitter Range of applications Hydrostatic Level measurement in dynamic temperature environments Pressure measurement in pipes
More informationAmphenol RF. Type N. Type N Connectors. Type N. Description. Features/Benefits. Applications
Amphenol RF 144 Connectors Description Named after Paul Neill of Bell Labs after being developed in the 1940 s, the offered the first true microwave performance. The connector was developed to satisfy
More informationTechnical Data. Dimensions
00 Model Number Features mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,
More informationSEALED CONNECTORS FOR THE LIMIT SWITCHES
SEALED CONNECTORS FOR THE LIMIT SWITCHES LIST OF MODELS / Sealed connectors are used at the cable-connecting section of limit switches. Type and appearance Materials Features Target market Applications
More informationGENERAL APPLICATION NOTES
GENERAL APPLICATION NOTES There are common considerations when using our connectors. Additional considerations may apply based on the particular connector being used, the application, and conditions in
More informationTechnical Data. Dimensions
0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable
More informationProportional Pressure-Relief Cartridge Valve, Size 2...4
Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description proportional pressure-relief valves are direct acting
More informationNickel-Plated Brass Right Angle Flow Control Valves NPTF/Inch Series GSCU, GMCU, GSVU, GMVU, GSCO, GMCO
Nickel-Plated Brass Right Angle Flow Control Valves NPTF/Inch Series GSCU, GMCU, GSVU, GMVU, GSCO, GMCO Swivel Design : Meter-Out, Meter-In and Needle Orifice Tube Diameter OD: 1/8, 5/2, 1/4, 5/16, /8
More informationInverse Prop. Pressure-Relief Cart., Size 2 4
Inverse Prop. Pressure-Relief Cart., Size Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description inverse proportional pressure-relief valves are direct acting screw-in
More informationTechnical Data. Dimensions
00 Model Number Features Comfort series 30 mm non-flush Accessories MHW 0 Modular mounting bracket V-G Female connector, M, 4-pin, field attachable V-W-N-M-PUR Female cordset, M, -pin, NAMUR, PUR cable
More informationSlit Valve. XGT Series. Low particle generation. With end lock mechanism. Service life of two million cycles. XLA XL XL Q D- XSA XVD XGT CYV
Slit Valve Series For 00 mm wafer Low particle generation L motion With end lock mechanism Can be held open/close of the gate when emergency stop. Service life of two million cycles. With SMC's life conditions.
More informationTwo-Wire In Situ Oxygen Analyzer (550 to 1400 C)
Product Data Sheet PDS 106-581.A01 March, 2004 Model 5081FG Two-Wire In Situ Oxygen Analyzer (550 to 1400 C) Intrinsically safe: - CENELEC EEx ia IIC - Class I Div. I Gr. B, C, D (pending) Operates at
More informationProduct Data Screwed Valves
Screwed Valves Brass and Chrome PVC Stainless Steel Flow Control Check Valves - 15mm Flow Control Check Valves - 25mm AUSTRALIA Maric Brass & Chrome Screwed Valves p. 28 Availability & Specifications Maric
More informationM8, M12, M18, M30 Cube 40 x 40 mm. 2 mm 15 mm 2 mm 15 mm 20 mm 40 mm
Bulletin 872C, 871TM, 871FM, 871C, 871P Product Line Overview Proximity Sensors (872C, 871TM, 871FM) 6 / 2011 Features Bulletin 872C 871TM 871P Size Sensing Range Standard Sensing Range Extended Sensing
More informationElectric regulating valves Type CCMT 2 - CCMT 8 / CCMT 16 - CCMT 42
Data sheet Electric regulating valves Type CCMT 2 - CCMT 8 / CCMT 16 - CCMT 42 The CCMT is an electrically operated valve designed specifically for operation in CO 2 systems. The CCMT valve concept is
More informationProportional pressure regulators VPPE
Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/
More informationInverse Proportional Pressure-Relief Cart., Size 2 4
Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 5 bar Direct acting, electrically operated 1 Description inverse proportional pressure-relief valves are direct acting screw-in cartridges
More informationPURA. Pure Gas Dewpoint Transmitter. Users Guide
PURA Pure Gas Dewpoint Transmitter Users Guide Issue January 2003 Page 2 Table of Contents SECTION PAGE 1 Product Overview 3 2 Preparation 3 3 Installation 3 3.1 PURA Premium & OEM Dewpoint Transmitter
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 5 mm
00 Model Number Features 5 mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,
More informationTechnical Data. Dimensions
0102 Model Number Features 2 mm flush Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 2 mm Installation flush Output
More informationTURQUOISE SWITCHES ABJ (BJ) SWITCHES
Ultra-miniature Size Sealed Switches TURQUOISE SWITCHES ABJ (BJ) SWITCHES Terminal type Mounting hole 2.3 mm type FEATURES Ultra-miniature size, High sealing performance sealed switches Elastomer double
More informationProportional Pressure-Relief Cartridge Valve, Size 2...4
Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min, p max = 3 bar Direct acting, electrically operated 1 Description proportional pressure-relief valves are direct acting screw-in cartridges
More informationSolenoid valves VZWF, force pilot operated
Key features and overview Function Normally closed solenoid valve with diaphragm and forced lifting. When the solenoid is energised, the differential pressure from the secondary side of the diaphragm is
More informationPegasus Series Amphenol Pcd
Pegasus Series Amphenol Pcd Amphenol Pcd is one of the world s leading suppliers of interconnect products for Military, Commercial Aerospace and Industrial applications. Located north of Boston in Beverly,
More informationSCHRADER TANK VALVES FOR USE IN AIR BLADDER APPLICATIONS, BICYCLE SUSPENSION SYSTEMS, TELECOMMUNICATIONS, WATER STORAGE SYSTEMS, ETC.
SCHRADER TANK VALVES FOR USE IN AIR BLADDER APPLICATIONS, BICYCLE SUSPENSION SYSTEMS, TELECOMMUNICATIONS, WATER STORAGE SYSTEMS, ETC. Demand an authentic Schrader valve built by the company that set the
More informationPRODUCT SPECIFICATION
MINI-FIT SR. SERIES 1.0 SCOPE This specification covers the 10.00 mm / (.394 in.) centerline tin and gold plated connector series, single and dual row versions in wire to wire and wire to printed circuit
More informationIndustrial Products Catalog Tank Valves
Industrial Products Catalog Tank Valves Schrader International core competencies include high volume precision machining, assembly and testing of fluid control devices. Since developing the first pneumatic
More informationElectrically Operated Pressure-Relief Cartridge, Size 10
Electrically Operated Pressure-Relief Cartridge, Size 1 Q max = 14 l/min (37 gpm), p max = bar (5 psi) seated pilot stage, spool-type design, with remote contral port Z Series WUVPOC-2, WUVPLC-2 1 Description
More informationType MMV Medium Power Cable
7-05 Type MMV Medium Power Cable Single Conductor: 5kV 5kV, 00% & % Insulation Levels. Rated 90 C Multi-Conductor: 5kV 5kV, 00% & % Insulation Levels. Rated 90 C Conductors Soft annealed flexible stranded
More informationD-Sub Vertical Surface Mount Connectors RoHS compliant Economical Interface Solution for SMT Applications
D-Sub Vertical Surface Mount Connectors RoHS compliant Economical Interface Solution for SMT Applications General In the manufacture of assemblies, the trend toward using SMT components is unbroken. Whereas
More informationInverse Proportional Pressure-Relief Cart., Size 2 4
Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 35 bar Direct acting, electrically operated Description Compact construction for cavity type AL 3/-6 UNF Operated by a proportional
More informationCell Injury Controller II (CIC II)
Cell Injury Controller II (CIC II) CIC II Operation Manual Contents Introduction 2 Quick-Start 2 Theory of Operation 3 Injury Measurement Method 3 Components 4 External Requirements 4 Front Panel 5 Rear
More informationSOLENOID VALVES AND PNEUMATIC VALVES
9 S E R I E S Electropneumatically and pneumatically operated valves Series 9 Assembly with sub-base (ISO 5599/1 Standards) Sizes 1, 2 and 3 The Series 9 electropneumatically or pneumatically operated
More informationInverse Proportional Pressure-Relief Cartridge, Size 10
Inverse Proportional Pressure-Relief Cartridge, Size 1 Q max = 12 l/min, p max = 3 bar Seated pilot, spool-type main stage, damped design 1 Description inverse-proportional pressure-relief valves are size
More informationInstallation, operating and maintenance Instructions for Seemag bypass level indicator
Issue: S Date: 05-09-14 Type G35 General information The Seetru bypass magnetic level indicator, abbreviate SEEMAG, serves to show the filling level of fluids in tanks, basins, tubes etc. The Seemag operates
More informationPrewired position switches FA series
2 Prewired position switches FA series Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 51 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable lever 41 45
More informationBSP Pressure Sensor Balluff GmbH, BA Marco Zorcic.
1 2 Standard Pressure Sensor with display Overview Pressure Range Relative nominal Overload Burst Permitted negative -1..2 bar 2 bar 4 bar 10 bar -1..10 bar 10 bar 20 bar 35 bar 0..2 bar 2 bar 4 bar 10
More informationModel PDT Dewpoint Transmitter
Model PDT Dewpoint Transmitter Instruction Manual Alpha Moisture Systems Alpha House 96 City Road Bradford BD8 8ES England Tel: +44 1274 733100 Fax: +44 1274 733200 email: mail@amsytems.co.uk web: www.amsystems.co.uk
More informationLesman Level Instrumentation LSB100/300 Series Basic Bubbler System
Lesman Level Instrumentation LSB100/300 Series Basic Bubbler System PART 1: GENERAL 1.1 SCOPE A. This section describes the specifications of a bubbler system. B. The following information shall be described
More informationCompact differential pressure switch Flameproof enclosure Ex d Models DE, DEC
Mechatronic pressure measurement Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC WIKA data sheet PV 35.41 Process Compact Series Applications Differential pressure monitoring
More informationESE SERIES. Series Overview. Specifications
Series Overview + Compact Capsule Design + Fully Compliant With IEEE 802.3 Formats + 100Base-T / 1000Base-T Ethernet Cable + T568B Wiring Terminated With RJ45 Connectors + High Quality Gold on Gold Contacts
More informationPiloted Non-Return Valves
ed Non-Return Valves ed non-return valves are designed to protect installations: if the compressed air supply is removed, they lock the air supply to the cylinder, thus maintaining it in position. Product
More informationRelief Valves. Relief Valves. International, Inc. Company ACIRCOR. RS Differential NB 9.5mm. RVA In-line Differential NB 6 to 19mm
s s RS Differential NB 9.5mm RVA In-line Differential NB 6 to 19mm RV Direct Acting NB up to 9mm LPR Low Pressure Differential NB 8mm We design, machine, build and test all our products on one site in
More informationZelio Relays RSL Slim Interface Plug-In Relays
Zelio Relays RSL Slim Interface Plug-In Relays Catalog 8501CT0901 2009 Class 8501 CONTENTS Description............................................. Page Introduction.................................................3
More informationItem No.: /
mounting types; for parallel or perpendicular mounting; pin spacing mm / 0197 in; 4-pole - Item No: 769- Male connector; with CAGE CLAMP connection and fixing flanges; for screw or similar mounting types;
More informationPilot Check Valve: Metal Body Type
INFORMATION Pilot Check Valve: Metal Body Type The use of a metal body improves strength and environmental resistance. Temporary intermediate stops are possible. *1 *1 Precise intermediate stops are not
More informationBW0500AO. ByWire Elements BW0500AO Element 4/3 with side ports IBW0500 Interface
ywire Elements Element 4/3 with side ports IW5 Interface efore use, carefully read the GENERL INSTRUCTIONS FOR USE OF DIRECTIONL CONTROL VLVES 398SW5EN - 5--8 Technical data Nominal flow 5 l/min 3. US
More informationParts Manual. Versa Hand Arm
Parts Manual Versa Hand Arm Insist Versa Hand To ensure u i our web site at www.labrieplus.com, or contact us at -800-23-277 USA or -877-83-8250 Canada twenty four hours a day. seven days a week. We are
More informationProp. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08
Prop. -Way Pressure-Reducing Cart., Size / SAE 8 Q max = 1 l/min (4 gpm), p max = bar (6 psi) Direct acting, electrically operated 1 Description proportional -way pressure-reducing cartridges are size
More informationExpert Hydrostatic Level Transmitters
Expert Hydrostatic s General Features MJK Expert hydrostatic level transmitters are designed for level measurement by submerging the transmitter in open channels, drains and tanks. Expert hydrostatic level
More informationF l o w c o n T R o l v a l v E S
Composite Right Angle Flow Control Valves Series TMCU-TMVU-TMCO- BSP/METRIC Meter In, Meter Out, Needle Orifice G1/8, G1/, G3/8, G1/2 Banjo flow controllers Nominal diameters Ø 2-3.8-5.8-8 The Meter In,
More informationSMB Series. SMB Series. Specifications. Interface Dimensions. Available in 50 Ohm and 75 Ohm versions. Snap-on interface reduces installation time.
Available in 50 Ohm and 75 Ohm versions. Snap-on interface reduces installation time. Self-cleaning outer spring withstands moderate vibration. Small & lightweight. Frequency Range: Up to 4 GHz Specifications
More informationPneumatic high-pressure controller Model CPC7000
Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Healthcare and avionics industry Industry (laboratory, workshop and production) Transmitter
More informationEPP4 Pressure Regulator Basic G 1/4"
EPP4 Pressure Regulator Basic G 1/4" Flow Curve 1/4" Dimensions Outlet pressure - bar 9 8 7 6 5 4 3 2 1 0 0 20 40 60 70 80 100 120 Flow rate - Nm 3 /h The male connector adopted on the EPP4 is a standard
More informationProportional Throttle Cartridges, Size 16
Proportional Throttle Cartridges, Size 16 Q max = 5 l/min, p max = 5 bar, Q N max = 14 l/min at p 1 bar Two-Stage, with Seat-Valve Shut-Off 1 Description Normally closed Seat-valve shut-off from 1 Compact
More informationOuter contact 1.0 milliohm max.
MCX.4 11/27/01 5:17 PM Page 17 Connex MCX Series connectors are ideal for applications and designs where weight and space savings are critical. This series has a 50 ohm impedance structure which operates
More informationG1/8 G1/8. Model 0 bar -0,1 bar -0,2 bar -0,3 bar -0,4 bar -0,5 bar -0,6 bar -0,7 bar -0,8 bar
single stage pumps M/5811 Very high induced air capacity % lower air consumption than comparable single stage units No wearing parts Compatible with a wide range of line contaminants llows direct connection
More informationTechnical explanations for mechanical pressure switches
Technical explanations for mechanical pressure switches 7 6 5 4 7 5 6 4 Diaphragm pressure switch NO Piston pressure switch NC Change over 3 2a 1 3 2b 10 9 What is a mechanical pressure switch? Mechanical
More informationPneumatic spool valve islands
Pneumatic spool valve islands P7.GB.R MEGA SPOOL VALVE ISLANDS MEGA pneumatic spool valve islands offer maximum performance along with flexibility, easy installation and simple operation. Due to their
More informationFlexible Metal Hose Products
Flexible Metal Hose Products Specialty Flexible Hose Solutions of Stainless Steel The AEROCOM Advantage Aerocom offers engineered solutions that address specific flexible piping challenges such as vibration,
More informationPressure switch and Thermostat CAS
Data sheet Pressure switch and Thermostat CAS The CAS Series consists of a series of pressure controlled switches and temperature controlled switches. In this series, special attention has been given to
More informationPneumatic high-pressure controller Model CPC7000
Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Automotive and avionics industry Industry (laboratory, workshop and production) Transmitter
More informationSMARTen STP Patch Cords Features
Features Patch Cords are used in the work area and cross-connect generic cabling applications Comprise a length of eight-wire flexible patch cable, terminated with two eight-position RJ-45 plugs at each
More informationLuminus Series Amphenol Pcd
Luminus Series Amphenol Pcd Amphenol Pcd is one of the world s leading suppliers of interconnect products for Military, Commercial Aerospace and Industrial applications. Located north of Boston in Beverly,
More informationPrecision Liquid Settlement Array Manual
Precision Liquid Settlement Array Manual All efforts have been made to ensure the accuracy and completeness of the information contained in this document. RST Instruments Ltd reserves the right to change
More informationMOUNTING SURFACE MOUNTING POSITION MAXIUMUM OPERATING PRESSURE FLUID OPERATING VISCOSITY FLUID CLEANLINESS HYSTERESIS REPEATABILITY THRESHOLD VOLTAGE
TYPICAL PERFORMANCE SPECIFICATIONS DESCRIPTION These proportional valves are direct operated pressure reducing valves. They can be used to control pressure in parts of a circuit. This valve incorporates
More informationP499 Heavy Duty Pressure Transducer
P499 Heavy Duty Pressure Transducer Product Bulletin Code No. LIT-??? E Issued 11 2006 The P499 Series is a new global Pressure Transducer with an excellent price performance ratio. The P499 exceeds the
More informationPressure Transmitters 36 F-27839
Pressure Transmitters 36 F-27839 SPD310/SPD360 Air Differential schneider-electric.com 37 SPD310/SPD360 SPD310/SPD360 differential pressure transmitters are intended for use in air handling systems for
More information9700 Transmitter Submersible hydrostatic level transmitter
Specification sheet IP0078 October 2007 Level 9700 Transmitter Submersible hydrostatic level transmitter Description The 9700 series hydrostatic level transmitter is designed to perform in the most arduous
More informationScrew Terminal Block Cables
9 Screw Terminal Block s Pre-terminated s Simplify of Terminal Blocks to PLC Modules 1 Reduce setup time with cables pre-terminated for the exact PLC module in use 1 No need to make custom connectors 1
More informationellison sensors international
PR3900 HAZARDOUS AREA PRESSURE TRANSMITTER ATEX CERTIFIED AND ALL EQUIVALENTS FOR HAZARDOUS AREAS: ZONE 0 GAS GROUP IIC, TEMPERATURE CLASS T4 AND ZONE 20 DUST PROTECTION BY INTRINSIC SAFETY TO EEXIA IIC
More information97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO
97C COMPRESSOR KIT 12V PART NO. 00097 97C COMPRESSOR KIT 24V PART NO. 02497 98C COMPRESSOR KIT PART NO. 00098 97C 98C IMPORTANT: It is essential that you and any other operator of this product read and
More informationDigital Flow Switch. Series PFM7
Compatible with rgon (r), Carbon Dioxide (CO) and the Mixed Gas (r+co) Digital Flow witch eries PFM7 Flow adjustment valve Fluid r, CO r + CO RoH -color display ee abnormal values at a glance. llows flow
More informationEPIC Rectangular Connectors HBE Series
HBE Series The HBE series inserts are suitable for applications with high voltages and current. The inserts can be terminated in a variety of ways: screw, crimp, or spring cage clamp. TECHNICAL DATA Number
More informationVACUUM REGULATORS CONTENTS
CAD drawing data catalog is available. ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Small Regulators Features 759 Specifications, Order Codes, Flow Rate
More informationAPPLICATIONS ROV & AUV SEISMIC PRODUCTION SYSTEMS DOWNHOLE JUMPER & CABLE SYSTEMS DRILLING CONTROL
APPLICATIONS ROV & AUV SEISMIC PRODUCTION SYSTEMS DOWNHOLE JUMPER & CABLE SYSTEMS DRILLING CONTROL ROV & AUV PRODUCTS GRE (Glass Reinforced Epoxy) CS-MS 55 & 66 SERIES MINI-CON HUMMER GLOBE-CON ALL-WET
More informationPush-in fittings CRQS, stainless steel
Features Application Effortless selection of the right fitting. Festo offers a secure solution for every connection. The convenient push-in fitting system includes well over 1000 types of standard and
More informationACV-10 Automatic Control Valve
ACV-10 Automatic Control Valve Installation, Operation & Maintenance General: The Archer Instruments ACV-10 is a precision automatic feed rate control valve for use in vacuum systems feeding Chlorine,
More informationDifferential pressure controls/ Lube oil protection controls MP 54 and MP 55 REFRIGERATION AND AIR CONDITIONING. Technical leafl et
Differential pressure controls/ Lube oil protection controls MP 54 and MP 55 REFRIGERATION AND AIR CONDITIONING Technical leafl et Contents Page Introduction... 3 Features... 3 Approvals... 3 Materials
More informationVEP Series VEP-BOP Series. canada.dixonvalve.com Customer Service:
UFACTURING QUALITY SERVICE MANUFACTURING QUALITY SERVICE MANUFACTURING QUALITY SERVICE MANUFAC VEP Series VEP-BOP Series Customer Service: 877.963.4966 Body Technical Specifications Pressure Rating Burst
More informationKMT. Thermal Mass Flowmeter. for compressed air and gases. Measuring range: Nm³/h Nm³/h
Thermal Mass Flowmeter for compressed air and gases measuring monitoring analysing KMT Measuring range: 0.32... 63 Nm³/h - 263.4... 263350 Nm³/h Accuracy: ± 1.5% of reading + 0.5% of full scale ( DN 50)
More informationElectro-hydraulic control valve - Calibrate - Remote valve calibration
Electro-hydraulic control valve - Calibrate - Remote valve calibration T9.390, T9.450, T9.505, T9.560, T9.615, T9.670 The CAN-based EHR valves need to be calibrated prior to use. Before calibrating the
More informationAMTEC SUPPORT GRIPS STANDARD, HEAVY DUTY & CONDUIT GRIPS
AMTEC SUPPORT GRIPS STANDARD, HEAVY DUTY & CONDUIT GRIPS DESIGNED TO HOLD THE WEIGHT FOR ELECTRICAL CABLE AS IT HANGS IN VERTICAL, SLOPING OR HORIZONTAL POSITIONS. EASILY INSTALLED AND REMOVED USING NO
More informationHand lever valves VHER
Hand lever valves VHER Hand lever valves VHER Key features Powerful Flexible Practical -M- Flow 170 3800 l/min 4/3-way valve mid-position closed mid-position exhausted mid-position pressurised Connections:
More information*NOTE: 75 OHM SERIES CONNECTORS ARE NOT INTERMATEABLE WITH THE 50 OHM SERIES.
The Connex N connectors with screw coupling are fully interchangeable with N connectors made to the MIL-C-39012 specification. Designed for use in all systems where very good R.F. and mechanical performance
More information(1) Type (2) Thread size (T) (3) Wrench size specification : inch spec. (NPT, UNF) : mm spec. (M, R)
This exhaust needle valve, which comes with silencer, controls the exhaust flow rate. The valve can be attached directly to a solenoid valve where a cylinder or like mechanism has no sufficient space around
More information1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type
Flow Control Valve Series LVM.. high flow rates (8 l/min) flow rates are unaffected by temperature change or when the higher load pressure alternates between the outlet ports proportional flow-sharing
More informationDMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.
Pressure Transmitter for Marine and Offshore Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0. % FSO Nominal pressure from 0... 40 mbar up to 0... 0 bar Output signals -wire:
More informationFeatures. Description
Features Fast response flow meter ideal for inert gas and liquid mass flow measurement applications Smart electronics permit field adjustment of critical flow meter settings Field validation of flow meter
More informationHow to specify a product. Process Sensors and Mechanical Instruments
How to specify a product Process Sensors and Mechanical Instruments Keep the overview. Here is some guideline information on how to specify our products. Intended as supplementary help to specification
More informationAir Purge Unit. Series: LSP-compact Type: EJG 2-2. (Controlled with DigiFlow 515) Installation & Operation Manual 11/2014
Air Purge Unit Series: LSP-compact Type: EJG 2-2 (Controlled with DigiFlow 515) Installation & Operation Manual 11/2014 Headquarters Sales Office BENELUX Intra-Automation GmbH B. V. Intra-Automation HTP
More informationAUTO PUMP STATUS CENTER
INSTRUCTION MANUAL AUTO PUMP STATUS CENTER PRESSURE ONLY MODEL #: 091-198-12-AP File: IM_091-198-12-AP_revD.indd Rev: D, pg 3 WD Revised By: PSS Date: 2-01-2016 3 YEAR WARRANTY INTRODUCTION The Auto Pump
More informationPressure Transmitter P41
SENSORS FOR AND BIOPHARMA. Product Information P41 Pressure Transmitter P41 Application/Specified usage Pressure measurement in pipes and tanks For process temperatures up to 250 C (428 F) with optional
More informationCALEFFI. Ball zone valves. series /03 GB
all zone valves series cert. n ISO / Function Zone valves are used to automatically shut-off the flow of carrier fluid distributed to a system. Specifically: -In central heating systems, they support the
More informationTightness controls TC 1 3 and TC 4
Tightness controls TC 1 3 and TC 4 Test of both safety valves Short test period thanks to logical decision-making in the program sequence Adjustable test period which can be adapted to different systems
More informationREF Description Picture Technical data Page
Dosing equipment REF Description Picture Technical data Page D Piston dosage ECON 4, 6, 7, 0 VDC approx. 45W (40%ED/S) 50-00 g/0sec Tolerance ±0% Vmax to 60km/h Price **** Pmin: 6bar D4 P5 piston dosage
More informationMicroregulator 039 1/8-1/4
09/11/15 TECH DATA SHEET 675 Microregulator 1/8-1/4 Sensitive high performance model, high stability with low load losses and big flow rate. Downstream overpressures quickly eliminated. Can be wall mounted
More information