THAI LIN RADIO COIL LTD.
|
|
- Russell Jones
- 6 years ago
- Views:
Transcription
1 #1 #2 #3 #4 #5 # # #8 #7 #6 Bottom View Type EI30 / 15.5 Трансформаторы герметизированные EI30x VA Power 1.8/2.1/2.4/2.6VA Frequency 50/60 Hz Temperature class Class B (130 C) Ambient temperature (ta) 40 C or 70 C Dielectric strength 4000Vrms Potted under vacuum Inherently short-circuit-proof approvals TUV / : EN61558 / EN6050 UL: ; UL / -2 / -3 (Class 2) : CSA C22.2 #66 / #66.1 / #66.2 / #66.3 : GB / GB A F F F F A B C D E F G Weight (g) Dimension (mm) SQ Tolerance (mm) ±0.5 ±0.5 ±0.5 ±1.0 ±0.1 ±0.2 ±0.5 approx. Note: Unused pins are omitted for standard parts. Unused pins can be provided upon request. Schematics #5 #5 #6 #7 SEC 1 #7 PRI SEC PRI # # SEC 2 #1 #1 # TL30S / TL30US / TL30HS THAI LIN RADIO COIL LTD. C D B G TL30D / TL30UD / TL30HD #5 #5 #6 PRI 1 #7 PRI 1 SEC 1 #4 #4 #7 SEC 1 #2 #2 # PRI 2 # PRI 2 SEC 2 #1 #1 # TL30MS E TL30MD 0
2 Pins Connection (for dual windings items) Designation Single input: Type of Designation 1) TL30x-yyy-zzz 2) Dual input: TL30Ux-yyy-zzz Type of Designation 1) TL30Mx-yyy-zzz 2) TL30MD-yyy-zzz Secondary CN (N) (NC2) w/o suffix (C2) w/o suffix CN (C2) In In Parallel In In Parallel Pin 1 Pin 5 (Pins 2, 4 short) Pin 1 Pin 5 (Pins 1, 4 short; Pins 2, 5 short) Pin 7 Pin (Pins 6, short) Pin 7 Pin (Pins 7, short; Pins 6, short) Suffix Product with (GB GB1212.7) Product with TUV (EN EN ) Product with TUV & UL-Class 2 (EN EN UL CSA C22.2 # ) Product with UL ( + CSA C22.2 #66) Product with UL-Class 2 ( UL CSA C22.2 # ) Suffix Product with TUV & UL (EN EN CSA C22.2 # ) Product with (GB GB1212.7) Product with TUV & UL-Class 2 (EN EN UL CSA C22.2 # ) (Z) Product with providing unused Pin #8 Note: (1) x S: one secondary winding D: two secondary windings yyy 3 digit numbers indicate times the rated output voltage zzz 3 digit numbers indicate the rated output current (2) In case of need, please add the appropriate suffixes in the part number when ordering. 1 belterratrans@gmail.com Веб-сайт:
3 * TL30S * TL30D x * TL30S * TL30S * TL30D * TL30D * TL30S TL30D x 0 70 TUV * TL30S TL30D x * TL30S TL30D x * TL30S TL30D x TL30S TL30D x TL30US TL30UD x TL30US TL30UD TL30US TL30UD TL30US TL30UD x TL30US TL30UD x TL30US TL30UD x TL30US TL30UD x TL30US TL30UD x * TL30US (C2) * TL30UD (C2) 2 x * TL30US (C2) 250 * TL30UD (C2) 125 * TL30US (C2) 200 * TL30UD-00-0 (C2) 0 * TL30US (C2) VA * TL30US (C2) * TL30US (C2) * TL30US (C2) 18 0 * TL30MS * TL30MD x * TL30MS * TL30MD * TL30MS * TL30MD (Parallel) * TL30MS TL30MD x 0 or 70 * TL30MS TL30MD x () * TL30MS TL30MD x * TL30MS TL30MD x TL30MS TL30MD x TUV TL30HS TL30HD x TL30HS TL30HD TL30HS TL30HD TL30HS TL30HD x TL30HS TL30HD x TL30HS TL30HD x TL30HS TL30HD x TL30HS TL30HD x * TL30S * TL30D x * TL30S * TL30D * TL30S TL30D * TL30S TL30D x 5 2.1VA 70 TUV * TL30S TL30D x * TL30S TL30D x TL30S TL30D x 18 5 TL30S TL30D x Note: Items marked with * are approved to UL (Class 2) & : CSA C22.2 No
4 2.1VA 2.4VA 115 TL30US TL30US TL30US TL30US-0-2 TL30US TL30US TL30US TL30US TL30UD TL30UD TL30UD TL30UD-0-5 TL30UD TL30UD TL30UD TL30UD x 6 2 x 2 x 12 2 x 15 2 x 18 2 x 24 * TL30US (C2) * TL30UD (C2) 2 x * TL30US (C2) 22 * TL30UD (C2) 146 * TL30US (C2) 234 * TL30US-0-2 (C2) * TL30US (C2) * TL30US (C2) * TL30MS * TL30MD x * TL30MS * TL30MD * TL30MS TL30MD (Parallel) * TL30MS TL30MD x 5 or 70 * TL30MS TL30MD x () * TL30MS TL30MD x TL30MS TL30MD x 18 5 TL30MS TL30MD x TUV TL30HS TL30HD x TL30HS TL30HD TL30HS TL30HD TL30HS TL30HD x TL30HS TL30HD x TL30HS TL30HD x TL30HS TL30HD x 18 5 TL30HS TL30HD x TL30S TL30S TL30D TL30D x TL30S TL30S TL30D TL30D x TUV 40 TL30S TL30D x 12 0 TL30S TL30D x TL30S TL30D x TL30S TL30D x TL30US TL30UD x TL30US TL30UD TL30US TL30UD TL30US TL30UD x TL30US TL30UD x 12 0 TL30US TL30UD x TL30US TL30UD x TL30US TL30UD x Note: Items marked with * are approved to UL (Class 2) & : CSA C22.2 No
5 2.4VA 2.6VA 115 (Parallel) or () TL30MS TL30MD x TL30MS TL30MD TL30MS TL30MD TL30MS TL30MD x TUV TL30MS TL30MD x 12 0 TL30MS TL30MD x TL30MS TL30MD x TL30MS TL30MD x TL30HS TL30HD x TL30HS TL30HD TL30HS TL30HD TL30HS TL30HD x TL30HS TL30HD x 12 0 TL30HS TL30HD x TL30HS TL30HD x TL30HS TL30HD x TL30S TL30D x TL30S TL30D TL30S TL30S TL30D TL30D x TUV 40 TL30S TL30D x 12 8 TL30S TL30D x TL30S TL30D x TL30S TL30D x TL30US TL30UD x TL30US TL30UD TL30US TL30UD TL30US TL30UD x TL30US TL30UD x 12 8 TL30US TL30UD x TL30US TL30UD x TL30US TL30UD x TL30MS TL30MD x TL30MS TL30MD TL30MS TL30MD (Parallel) TL30MS TL30MD x 130 or 40 TUV TL30MS TL30MD x 12 8 () TL30MS TL30MD x TL30MS TL30MD x TL30MS TL30MD x TL30HS TL30HD x TL30HS TL30HD TL30HS TL30HD TL30HS TL30HD x TL30HS TL30HD x 12 8 TL30HS TL30HD x TL30HS TL30HD x TL30HS TL30HD x Note: Items marked with * are approved to UL (Class 2) & : CSA C22.2 No
TURQUOISE SWITCHES ABJ (BJ) SWITCHES
Ultra-miniature Size Sealed Switches TURQUOISE SWITCHES ABJ (BJ) SWITCHES Terminal type Mounting hole 2.3 mm type FEATURES Ultra-miniature size, High sealing performance sealed switches Elastomer double
More informationDimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm
Dimensions 7 36 5 33.5 9 5.4 30 65 0102 Model Number Features Direct mounting on standard actuators Fixed setting Satisfies machinery directive Compact and stable housing EC-Type Examination Certificate
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 5 mm
00 Model Number Features 5 mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,
More informationDimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm
Dimensions 65 GW2 40 35 9 5 GW1 14 11 9 5.4 M20 x 1.5 0102 Model Number S M12 x 1.5 Features 77.5 LED V Direct mounting on standard actuators Compact and stable housing with terminal compartment connection
More informationDimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm
Dimensions 65 9 5 14 40 35 11 9 5.4 M20 x 1.5 0102 S Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting Satisfies
More informationTechnical Data. Dimensions
00 Model Number Features mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,
More informationDimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm
Dimensions 65 9 5 40 35 14 11 9 5.4 M20 x 1.5 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting Satisfies machinery
More informationTechnical Data. Dimensions
0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications
More informationTechnical Data. Dimensions
0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable
More informationTechnical Data. Dimensions
00 Model Number Features Comfort series 30 mm non-flush Accessories MHW 0 Modular mounting bracket V-G Female connector, M, 4-pin, field attachable V-W-N-M-PUR Female cordset, M, -pin, NAMUR, PUR cable
More informationTechnical Data. Dimensions
0102 Model Number Features 2 mm flush Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 2 mm Installation flush Output
More informationThe Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure
General-purpose Limit Switch CSM_DA-_N_DS_E The Limit Switch with Better Seal, Shock Resistance, and Strength A double seal on the head, a complete gasket cover, and other features ensure a better seal
More informationWatts. xppower.com. Input. General. Environmental. Output. EMC & Safety. Output Voltages from 2.5 V to 48 V. Non-standard Outputs Available
-0 Watts AEH Series s from. V to 8 V xppower.com Non-standard s Available Universal Input Single & Multiple Versions 0 C to +60 C Operating Temperature Efficiency up to 80% Non-standard Connectors Available
More informationTechnical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection
0102 Model Number Features Direct mounting on standard actuators Compact and stable housing Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up to SIL2 acc. to IEC 61508 Accessories
More informationZelio Relays RSL Slim Interface Plug-In Relays
Zelio Relays RSL Slim Interface Plug-In Relays Catalog 8501CT0901 2009 Class 8501 CONTENTS Description............................................. Page Introduction.................................................3
More informationDimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm
Dimensions M30x1,5 5 40 37 0102 Model Number 36 LED Features Comfort series 10 mm embeddable Connection BN BU Accessories BF 30 Mounting flange, 30 mm L+ L- Technical Data specifications Switching element
More informationSeries AM3T-VZ 3 Watt DC-DC Converter
Click on Series name for product info on aimtec.com Series AM3T-VZ FEATURES: Wide 2:1 Range 24 Pin DIP Package High up to 82% Metal Package Operating Temperature -4 o C to +85 o C / Isolation 15 or 35
More informationMiniature controls. Contactors. Overload relays. Starters. Control relays
Contactors Overload relays Starters Control relays Description General features Wiring terminations available include plugon connectors, wire pins for PC board mounting and solder connections Low power
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 1.5 mm
0102 Model Number Features 1.5 mm flush Accessories BF 8 Mounting flange, 8 mm Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 1.5 mm Installation flush
More informationTechnical Data. Dimensions
0102 Model Number Features 6 mm flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,
More informationTechnical Data. General specifications. Rated operating distance s n 5 mm
0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching
More informationTechnical Data. General specifications. Rated operating distance s n 2 mm
0102 Model Number Features 2 mm flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Rated operating distance s n 2 mm Installation
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 2 mm
0102 Model Number Features 2 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-12 Quick mounting bracket with dead stop BF 12 Mounting flange, 12 mm Technical Data specifications Switching
More informationDigital electro-pneumatic regulators Series ER100
CATALOGUE > Release 8.2 Digital electro-pneumatic regulators Series ER100 TREATMENT > Digital electro-pneumatic regulators Series ER100 Port G1/4» Compact design» Digital display» Analog and digital input»
More informationUL TEST REPORT AND PROCEDURE
Issue Date: 2015-01-30 Page 1 of 24 Report Reference # E186249-A270-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: UL 60950-1, 2nd Edition, 2014-10-14 (Information
More informationDimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm
Dimensions M18x1 37 40 4 0102 24 LED Model Number Features 5 mm embeddable Usable up to SIL2 acc. to IEC 61508 Connection BN BU Accessories L+ L- EXG-18 Quick mounting bracket with dead stop BF 18 Mounting
More informationPrewired position switches FA series
2 Prewired position switches FA series Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 51 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable lever 41 45
More informationTechnical Data. Dimensions
0102 Model Number Features Comfort series 15 mm non-flush Stainless steel housing Accessories BF 30 Mounting flange, 30 mm Technical Data specifications Switching element function NAMUR, NC Rated operating
More informationTechnical Data. Dimensions
0102 Model Number Features 10 mm flush Shielded PUR cable for oil and gas sector Accessories BF 30 Mounting flange, 30 mm Technical Data specifications Switching function Normally closed (NC) Output type
More informationTechnical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection
0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up
More information2-Phase Filters(Direct IEC Connector) RoHS. 250V AC 50/60Hz 1,2,3,6,10A KC, UL, CSA, VDE+ENEC, TÜV, CQC, 25 / 85 / 21
2-Phase Filters(Direct IEC Connector) IG IM IL IX ID Rated Voltage/ Frequency 1,2,3,6,10A KC, UL, CSA, VDE+ENEC, TÜV, CQC, Climatic Category IG, IX, ID : IM, IL : Plastic Case IG, IX, ID : Screw and PCB
More informationOperating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073
Operating instructions Safety Rope Emergency Stop Switches UK ZB0052 / ZB0053 ZB0072 / ZB0073 7390878 / 02 03 / 2011 Contents 1 Safety instructions...3 2 Installation / set-up...4 2.1 Applications...4
More informationPRODUCT SPECIFICATION
MINI-FIT SR. SERIES 1.0 SCOPE This specification covers the 10.00 mm / (.394 in.) centerline tin and gold plated connector series, single and dual row versions in wire to wire and wire to printed circuit
More informationSPECIFICATION FOR APPROVAL
RoHS Compliant SPECIFICATION FOR APPROVAL File No.: Q/FRK 0.GS.E.-F03 Product Name Product Type Safety class S3(P2) Metallized polypropylene film AC motor capacitor(box-type) [CBB61-S3(P2)] Product Code
More informationPosition switches FP series
A Position switches FP series Selection diagram 0 08 8 9 0 0 0 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fiber glass rod gasket sphere sphere adjustable lever safety adjustable lever
More informationGasSense NDIR User Manual
INDEX INDEX... 1 1. OVERVIEW... 2 2. TECHNICAL DATA... 3 3. SPECIFICATIONS... 4 4. PRODUCT DESCRIPTION... 5 4.1 Mechanical details... 5 4.2 Piping... 7 4.3 Connections... 7 5. INSTALLATION... 10 6. CALIBRATION
More informationJSP. MKT Series J S P -
Loose Taped Fig.1 Fig. 2 JSP Typical applications: blocking, coupling, decoupling, by-passing, interference suppression in low voltage applications (i.e.:automotive) Ød ±0.05 All dimensions are in mm.
More informationACCESSORIES. Standard packing
ACCESSORIES HC RELAYS (Sockets and Terminal ) FEATURES. HC Relay Sockets In the table below, the suitable for each type of HC relay is indicated by a black dot. ) Plug-in type, type, and wrapping type
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx CML 14.0034X Issue No:
More informationTELEDYNE HASTINGS INSTRUMENTS PRELIMINARY BULLETIN. Models HFM-D-301 & 305, HFC-D-303 & 307
TELEDYNE HASTINGS DIGITAL 300 MEDIUM/HIGH CAPACITY FLOWMETERS AND CONTROLLERS INSTRUMENTS Models HFM-D-301 & 305, HFC-D-303 & 307 FEATURES Flows to 2500 slm (N 2 Equivalent) Accuracy in Nitrogen ±(0.2%
More informationTolerance code. Lead space
FEATURES Non-inductive construction. Self-healing. Flame-retardant plastic case and epoxy resin (compliance with UL 94V-0). High moisture-resistance. Good solderability (plated with 100% Matte Sn). APPLICATIONS
More information2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version
2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version Type 6624 Impulse can be combined with... 10mm width orifice DN 0.8 to 1.2 with pressure range vacuum to 5bar medium separation, for
More informationSpeed Controller ADR 40 Condensing pressure controller SPEED REGULATORS FOR ASYNCHRONOUS SINGLE PHASE MOTORS SERIES ADR 40 ADR 40 ADR 40 PP
SPEED REGULATORS FOR ASYNCHRONOUS SINGLE PHASE MOTORS SERIES ADR 40 ADR 40 ADR 40 PP Control by pressure or temperature Pressure control 0-50 bar for all refrigerants Temperature control -20 to +100 C
More informationSocket P2RF-05-S P2RF-08-S Clip & Release Lever Nameplate R99-11
Screwless Clamp Terminal Socket P2RF@@S Screwless clamping greatly contributes to reducing wiring time. No over or under tightening of cable connection so better contact reliability is achieved. Double
More informationPressure switch KP-E. Data sheet
Data sheet Pressure switch KP-E KP-E pressure switches for use in refrigeration and air conditioning systems are equipped with SPDT gold plated contacts and stainless steel bellows. The high pressure switches
More informationto use the European Mark Licence No Date of issue: Wien, Rev. No. 03 Wien,
AUSTRIAN ELECTROTECHNICAL ASSOCIATION 1010 Wien, Eschenbachgasse 9 ZVR: 327279890 DVR: 1055887 Testing & Certification Kahlenberger Str. 2A 1190 Wien, Austria Phone: +43 1 370 58 06 Fax: +43 1 370 58 06-199
More informationSonoMeter 30 Energy Meters
Data Sheet SonoMeter 30 Energy Meters Description The Danfoss SonoMeter 30 is a range of ultrasonic, compact energy meters intended for measuring energy consumption in heating and cooling applications
More information4/2 way Pneumatic Solenoid Valve
4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11
More informationcompact ejector, Series ECM with Adjustable release pulse with silencer With filter vacuum switch: electronic 2 x PNP
00134428 Type Miniature compact injector Ambient temperature min./max. +0 C / +0 C Medium temperature min./max. +0 C / +0 C Working pressure min./max. 2. bar / 6 bar Medium Compressed air Max. particle
More informationSAPCON. User Manual. Capacitance Continuous Level Indicator. . Introduction. . General Description. . Principle of Operation. .
User Manual Capacitance Continuous Level Indicator Comprehensive User s Manual. Introduction. General Description. Principle of Operation. Specifications. Connection Diagrams. Quick Calibration Chart.
More informationVLT 2000 Series. How to size your VLT
Selection of frequency converter Usually the size of frequency converter is chosen on the basis of the shaft output, as this may be the only value known. However, if the data are known for both the application,
More informationSPECIFICATIONS ATTENTION
VPS 504 S06 Installation Manual - P/N 80122 - Ed. 01/09 VPS 504 S06 and S05 Valve Proving System Installation Instructions VPS 1 6 Gases Natural gas, air and other inert gases. NOT suitable for butane
More informationKTE6000 / KTU6000 Series OEM pressure transmitters for industrial media
FEATURES 50 mbar to 400 bar, 5 to 6000 psi gage or absolute pressure For many industrial gases and liquids 00, 0545, 05, 6 or 40 ma output Field interchangeable EMC according to EN 66-8 MEDIA COMPATIBILITY
More information2/ Port G1/4
CATALOGUE > Release 8.8 > Series ER100 digital electro-pneumatic regulators Series ER100 digital electro-pneumatic regulators Port G1/4 Compact design Digital display Analog and digital input Programmable
More informationValve Proving System VDK 200 A S06*
Valve Proving System VDK 200 A S06* Valve proving system with the following approvals. UL Recognized File # MH17004 CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter
More informationASSE International Product (Seal) Listing Program
ASSE International Product (Seal) Listing Program ASSE 1070-2015 / ASME A112.1070-2015 / CSA B125.70-15 Performance Requirements for Water Temperature Limiting Devices Manufacturer: Contact Person: E-mail:
More informationTeSys protection components
Presentation, description -pole thermal overload relays TeSys D Presentation TeSys D thermal overload relays are designed to protect a.c. circuits and motors against: b overloads, b phase failure, b excessively
More informationValve Proving System VDK 200 A S02
Valve Proving System VDK 200 A S02 Valve proving system with the following approvals. UL Recognized File # MH17004 CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter
More informationUser s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E
User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] 12th Edition 1 1. Introduction Thank you for purchasing the DPharp electronic pressure transmitter. This manual
More informationGuidelines to the standard IEC60601
EUROPEAN POWER SUPPLY MANUFACTURERS ASSOCIATION (Visit the EPSMA website at www.epsma.org) Medical Approvals for Power Supplies Guidelines to the standard IEC60601 Revision Date: 2009-09-12 This document
More informationMonitoring device NTS 30
P R O D U C T I N F O R M A T I O N Electronic level- and temperature monitoring device Monitoring device NTS 30 Contents Description Description... 2 Operating... 3 Design and electrical data... 4 Circuit
More informationFeatures hermetic shielded case very small phase variation
Plug-In Limiter 50Ω Broadband, 0.1 to 150 MHz Maximum Ratings Operating Temperature -55 C to 100 C Storage Temperature -55 C to 100 C RF Input Power 100mW Control Current 10mA Permanent damage may occur
More informationInductive slot sensor
0102 Model Number Features 3.5 mm slot width Usable up to SIL 3 acc. to IEC 61508 Nonferrous targets Application Danger! In safety-related applications the sensor must be operated with a qualified fail
More informationGas density monitor With integrated transmitter Model GDM-100-TI
SF 6 gas solutions Gas density monitor With integrated transmitter Model GDM-100-TI grid Products WIKA data sheet SP 60.05 for further approvals see page 5 Applications Gas density monitoring of closed
More informationTechnical Datasheet. Pressure Transmitter: Analogue Series 387. Performance characteristics. Product applications. How can we help you?
Technical Datasheet Pressure Transmitter: Analogue Series 387 387 ISSUE G High Accuracy ± 0.15%. Ranges from 1 bar to 1000 bar. 4 : 1 turndown. 4-20mA analogue with digital communications. 316 stainless
More informationDual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11
Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11 Two normally closed safety shutoff valves in one housing; each with the following approvals. CSA Certified ANSI Z21.21 CSA 6.5 Marked C/I
More informationIntrinsically safe solenoid valves on/off controls - ATEX certification
www.atos.com Table E130-17/E Intrinsically safe solenoid valves on/off controls - ATEX certification valve body valve spool intrinsically safe solenoid electrical connector manual override DHW-0611/WP/6
More informationtrafo_011_a_1_cat Bar or cable-through Multiple applications per: - cables: Ø 17 to Ø 100 mm, - bars: 20 x 5 mm to 2 x 125 x 10 mm.
Current transformers Measurement devices trafo_012_a_1_cat trafo_077_b_1_cat trafo_010_a_1_cat trafo_008_a_1_cat trafo_011_a_1_cat Functions SOCOMEC current transformers deliver to the secondary a standard
More informationDual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series
Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure DMV-D/624L Series DMV-DLE/624L Series Two normally closed automatic shutoff valves in one housing. Valve 2 (V2) incorporates proof
More information2/2-Way Solenoid Control Valve
2/2-Way Solenoid Control Valve Excellent range (1:200) Very good response Compact valve design Orifice sizes 0.05... 2.0 mm Port connection 1/8 or sub-base Type 2871 can be combined with Type 8605 Digital
More informationCurrent transformers. Measurement devices. 2 General Catalogue SOCOMEC. Measurement devices NEW. ÂÂEnergy efficiency
NEW trafo_108_a_1_cat Three-phase CT trafo_010_a_1_cat trafo_077_b_1_cat trafo_012_a_1_cat ÂÂEnergy efficiency 0.2s We offer class 0.2s for your energy efficiency or MD applications. appli_294_a ÂÂFunction
More informationxtreme DB Innovation Every Day Murrelektronik is your system partner: PIN ASSIGNMENTS INPUT OUTPUT AT A GLANCE
Deutsch Plug MDC06-s MDC06-s -0V AC/DC, A, R 707-70-xxxx V -0V AC/DC, A, 707-700-xxxx MJT-P -0V AC/DC, A, R 707-700-70xxxx V -0V AC/DC, A, & Suppression R 707-7006-70xxxx V -0V AC/DC, A, R 707-7000-70xxxx
More informationMeta-MEC Manual Motor Starters
www.lsis.biz Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 45 mm 70 mm 63AF 100AF 3 LS Meta-MEC Manual Motor Starters deliver more
More informationRELAY PRODUCT GUIDE CONTENTS
RELAY PRODUCT GUIDE CONTENTS 1.0 ABOUT FUJITSU COMPONENTS 1.1 Who we are Page 2 2.0 PRODUCT LINE-UP 2.1 Automotive relays Page 3 2.2 Power relays Page 8 2.3 Signal relays Page 16 2.4 High frequency relays
More informationDual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11
Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11 Two normally closed safety shutoff valves in one housing; each with the following approvals. CSA Certified ANSI Z21.21 CSA 6.5 Marked C/I
More informationDual Modular Safety Shutoff Valves. DMV-D/11 Series DMV-DLE/11 Series
Dual Modular Safety Shutoff Valves DMV-D/11 Series DMV-DLE/11 Series Two normally closed safety shutoff valves in one housing; each with the following approvals. CSA Certified ANSI Z21.21 CSA 6.5 Marked
More informationPrewired position switches FA series
Prewired position switches Technical data Housing Made of metal, coated with baked epoxy powder 2 m wired cable with 5x0,5 mm 2 wires marked SEV and IMQ Protection degree: IP6 General data Ambient temperature:
More informationSolenoid valves VZWF, force pilot operated
Key features and overview Function Normally closed solenoid valve with diaphragm and forced lifting. When the solenoid is energised, the differential pressure from the secondary side of the diaphragm is
More informationDual Modular Safety Shutoff Valve with NEMA 4x Enclosure. DMV-D/604L Series DMV-DLE/604L Series
Dual Modular Safety Shutoff Valve with NEMA 4x Enclosure DMV-D/604L Series DMV-DLE/604L Series Two normally closed automatic shutoff valves in one housing; each with the following approvals. UL Listed
More informationDual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series
Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure DMV-D/624L Series DMV-DLE/624L Series Two normally closed automatic shutoff valves in one housing. Valve 2 (V2) incorporates proof
More informationC-Flow Coriolis Mass Flow Meters
Coriolis Mass Flow Meters Ready for Take Off The New Compact C-Flow Küppers Elektromechanik GmbH The C-Flow The C-Flow Coriolis Mass Meters consist of two components: KCE Transmitter KCM Transducer 2 KEM
More informationDULUX L LUMILUX DE LUXE
www.osram.com EXCELLENT COLOR RENDERING LUMILUX QTP - DL 2x55/220-240 GII 1 Benefits Impressive quality of light Extremly economical Excellent luminous flux Improved lumen maintenance Long service life
More informationType Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.
2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies We reserve the right to make technical changes without notice. Technische Änderungen vorbehalten. Sous réserve de modifications techniques.
More informationDPS-400 SERIES DPH-100 SERIES
745 Dual Display Digital Pressure Sensor For Gas DPS-400 SERIES SERIES General terms and conditions... F- guide... P.699~ Related Information Glossary of terms... P.156~ General precautions... P.1566 PHOTO
More informationMeta-MEC Manual Motor Starters
Leader in Electrics & Automation Meta-MEC Manual Motor Starters Electric Equipment LG Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 45 mm 70 mm 63AF 100AF 3 LG Meta-MEC
More informationBest Practices for Installation of Gaseous Sample Pumps
Best Practices for Installation of Gaseous Sample Pumps Goal of the Gas Sample Pump Transport a clean, reliable, sample of the process gas to the analyzer, in the safest and easiest way possible, to ensure
More informationConductor Bushings Series 8174
> Current lead-in for Ex d enclosures > 1 to 72 conductors combined in one current lead-in > Series screw-in plug-in > For voltages up to max. 1 V > For size conductor up to 7 mm 2 www.stahl.de 3163E The
More informationAutomatic Valve Proving Control
ISO 9001 Automatic Valve Proving Control 7 696 LDU11 UL recognized FM approved Features Performs leak test of the gas shut-off valves before start-up and/or immediately after burner shut-down No inlet
More informationMULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE
SIT Group SIT -3- SIGMA MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE 9.955. Subject to change without notice Application Domestic gas appliances: central heating boilers, combi boilers, instantaneous
More informationDULUX L LUMILUX IMPROVED LIFETIME & SYSTEM GUARANTEE. DULUX L LUMILUX & QUICKTRONIC TECHNICAL INFORMATION 1.
www.osram.com IMPROVED LIFETIME & SYSTEM GUARANTEE QTP-M 1x26-42 TECHNICAL INFORMATION 1 Benefits Extremly economical Good quality of light Excellent luminous flux Improved lumen maintenance Long service
More informationTightness controls TC 1 3 and TC 4
Tightness controls TC 1 3 and TC 4 Test of both safety valves Short test period thanks to logical decision-making in the program sequence Adjustable test period which can be adapted to different systems
More informationRaising the bar. Philips Advance Optanium high efficiency instant start T8 ballasts have set new standards for maximizing energy savings
Raising the bar Philips Advance Optanium high efficiency instant start T8 ballasts have set new standards for maximizing energy savings Philips Advance Optanium high-efficiency electronic ballasts are
More informationVSD03M DIRECTIONAL CONTROL VALVES
NFPA SIZE D03 TYPICAL PERFORMANCE SPECIFICATIONS Performance is measured on a four-way circuit (full circuit). Performance may e reduced from that shown if a three-way circuit (half circuit) is used, i.e.
More informationCONTENTS TABLE OF MAIDA S HISTORY TERMINOLOGY & GENERAL SPECIFICATIONS. iii. LEAD CODES and TAPE & REEL STANDARD SERIES 1 HC SERIES 17
TABLE OF CONTENTS MAIDA S HISTORY TERMINOLOGY & GENERAL LEAD CODES and TAPE & REEL i ii iii STANDARD SERIES 1 HC SERIES 17 LOW PROFILE SERIES 33 THERMALLY PROTECTED SERIES 39 HIGH ENERGY SERIES LEAD CODES
More informationE2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information
Liquid Level EK-L CSM_EK-L_DS_E 3 Liquid Level That Is Unaffected by the Color of the or Liquid Mount to bypass pipes. Fit a wide range of pipe diameters: 8 to mm or to mm Built-in Amplifiers to save space.
More informationFMAC Sine FMAC Sine DCL
emc Sine Output Filter www.schurter.com/pg8 FMAC Sine FMAC Sine DCL -Phase Filters Sine wave output filter Description - Design corresponding to UL 128, CSA 22.2 No. 8, IEC/EN699 - Standard versions include
More informationM/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners
M/MR Modulating Valves design certified For Atmospheric, Infrared, and Direct Fired urners TALE OF CONTENTS Description/Specifications... 1 Introduction... 2 Direct Fired Applications (Negative Pressure)...
More informationATM.ECO/IS - Analog Transmitter with Temperature compensation
Pressure Transmitter - FM / FM-C certified ATM.ECO/IS - Analog Transmitter with Temperature compensation CUSTOMER BENEFITS Certificate: FM, FM-C & IECEx & ATEX Entry level series into precision pressure
More informationElectric expansion valves Types AKV 10, AKV 15 and AKV 20
Data sheet Electric expansion valves Types AKV 10, AKV 15 and AKV 20 AKV are electrically operated expansion valves designed for refrigerating plants. The AKV valves are normally controlled by a controller
More information