1 powr-bloks Applications Typical applications include heating, air conditioning and refrigeration systems, el e va tor systems, material handling equipment, control panels, motor controls, switchgear, and anywhere power needs to be distributed to more than one load. Description POWR-BLOKS TM power distribution blocks offer a safe, convenient way of splicing cables, providing a fixed junction tap-off point or splitting primary power into secondary circuits. Lx2xxx-DIN series offers integral DIN-Rail mount and an optional hinged safety cover. Optional power distribution block covers provide protection against accidental shorting between poles caused by loose wires, tools, or other conductive material. They also protect personnel from accidentally contacting energized connectors. To order protective covers, match the number of poles for the block to the cover. Hinged Plastic Covers number For use with Distribution/Splicer Block No. LCH LCH1321Z LD2xxx-1DIN / LS2xxx-1DIN 1 LCH LCH1322Z LD2xxx-2DIN / LS2xxx-2DIN 2 LCH LCH1323Z LD2xxx-3DIN / LS2xxx-3DIN 3 Note: Optional hinged covers snap on to blocks. Clear Plastic Covers Catalog/System number For use with Distribution/Splicer Block No. LPBC0-2 LPBC02 LD0xxx-2 / LS0xxx-2 2 LPBC0-3 LPBC03 LD0xxx-3 / LS0xxx-3 3 LPBC2-1 LPBC21 LD2xxx-1 / LS2xxx-1 1 LPBC2-2 LPBC22 LD2xxx-2 / LS2xxx-2 2 LPBC2-3 LPBC23 LD2xxx-3 / LS2xxx-3 3 LPBC3-1 LPBC31 LD3xxx-1 / LS3xxx-1 1 LPBC3-2 LPBC32 LD3xxx-2 / LS3xxx-2 2 LPBC3-3 LPBC33 LD3xxx-3 / LS3xxx-3 3 LPBC4-1 LPBC41 LD4xxx-1 / LS4xxx-1 1 LPBC4-2 LPBC42 LD4xxx-2 / LS4xxx-2 2 LPBC4-3 LPBC43 LD4xxx-3 / LS4xxx-3 3 LPBC5-1 LPBC51 LD5xxx-1 / LS5xxx-1 1 LPBC5-2 LPBC52 LD5xxx-2 / LS5xxx-2 2 LPBC5-3 LPBC53 LD5xxx-3 / LS5xxx-3 3 Note: For installation of optional clear plastic covers, use the screws provided with each cover. Connectors Box lug connectors are designed for use with a single, solid or class B or C stranded conductor. Use of more than one con ductor per connector opening or use of extra-flexible, fine-stranded conductors, such as welding cable, voids the UL Listing and may cause overheating. Manufacturers of cable ter minations can furnish crimp-on sleeves for fine stranded conductors which permit these conductors to be used with box lugs. Ampere Ratings The ampere rating per pole for power distribution blocks is based on the line ampacity of 75 C insulated conductors per NEC Table If 60 C insulated conductors are used, load must not exceed the ampacity of 60 C conductors. Use of conductors rated in excess of 75 C is permitted (for example 90 C), however, load must not exceed the ampacity of 75 C conductors. Specifications Voltage Rating: Current Rating: Material: Connector: 600 V Based on NEC Table , using 75 C copper wire Phenolic rated at 150 C and Thermoplastic rated at 125 C (LD1400 and LS1300 series only) Standard: Highly con duc tive aluminum, tin plated Copper: Highly conductive copper, tin plated Flammability Rating: UL94 V-0 Approvals: UL Recognized (File No. E171395) CSA Certified (File No. LR700111) Ordering Information Distribution Block Example Part No. Splicer Block Example Part No. Note: Aluminum blocks can use copper or aluminum wire; copper blocks can only use copper wire. Web Resources For more information, visit: /powr-bloks 1

2 Distribution Block Selection Guide Connector Configuration Material Line Load =Aluminum, =Copper Amp Rating Line Load Outline Drawing per Wire Openings Wire Openings Number Figure Pole Range per Pole Range per Pole #2 - #14 1 #10 - # LD LD14001Z #2 - #14 1 #10 - # LD LD14002Z #2 - #14 1 #10 - # LD LD14003Z #2 - #14 1 #10 - # LD LD14004Z #14 1 #4 - # LD LD04012Z #14 1 #4 - # LD LD04013Z #14 1 #4 - # LD LD04022Z #14 1 #4 - # LD LD04023Z mcm - #6 1 #4 - # LD LD04042Z mcm - #6 1 #4 - # LD LD04043Z #14 1 #4 - # LD LD25701Z #14 1 #4 - # LD LD25702Z #14 1 #4 - # LD LD25703Z #14 1 #4 - # LD LD29701Z #14 1 #4 - # LD LD29702Z #14 1 #4 - # LD LD29703Z mcm - #6 1 #2 - # LD LD35521Z mcm - #6 1 #2 - # LD LD35522Z mcm - #6 1 #2 - # LD LD35523Z mcm - #6 1 #2 - # LD LD35531Z mcm - #6 1 #2 - # LD LD35532Z mcm - #6 1 #2 - # LD LD35533Z #14 2 #4 - # LD LD35551Z #14 2 #4 - # LD LD35552Z #14 2 #4 - # LD LD35553Z mcm - #4 1 #2 - # LD LD39531Z mcm - #4 1 #2 - # LD LD39532Z mcm - #4 1 #2 - # LD LD39533Z #14 2 #4 - # LD LD39551Z #14 2 #4 - # LD LD39552Z #14 2 #4 - # LD LD39553Z mcm - #4 1 #2 - # LD LD45511Z mcm - #4 1 #2 - # LD LD45512Z mcm - #4 1 #2 - # LD LD45513Z mcm - #6 1 #2 - # LD LD45601Z mcm - #6 1 #2 - # LD LD45602Z mcm - #6 1 #2 - # LD LD45603Z mcm - #4 1 #2 - # LD LD55521Z mcm - #4 1 #2 - # LD LD55522Z mcm - #4 1 #2 - # LD LD55523Z mcm - # # LD LD55791Z mcm - # # LD LD55792Z mcm - # # LD LD55793Z mcm - # # LD LD55861Z mcm - # # LD LD55862Z mcm - # # LD LD55863Z mcm - # mcm - # # LD LD55871Z mcm - # mcm - # # LD LD55872Z mcm - # mcm - # # LD LD55873Z 2

3 Distribution Block Selection Guide Connector Configuration material Line Load Amp Rating per Pole Line Load Outline Drawing Wire Openings Wire Openings Range per Pole Range per Pole Figure Number mcm-#4 2 #4 - # LD LD55921Z mcm-#4 2 #4 - # LD LD55922Z mcm-#4 2 #4 - # LD LD55923Z mcm-#4 1 #2 - # LD LD55941Z mcm-#4 1 #2 - # LD LD55942Z mcm-#4 1 #2 - # LD LD55943Z mcm-# # LD LD59861Z mcm-# # LD LD59862Z mcm-# # LD LD59863Z mcm-#4 2 #2 - # LD LD59921Z mcm-#4 2 #2 - # LD LD59922Z mcm-#4 2 #2 - # LD LD59923Z #14 1 #4 - # LD2570-1DIN 0LD25701ZXDIN #14 1 #4 - # LD2570-2DIN 0LD25702ZXDIN #14 1 #4 - # LD2570-3DIN 0LD25703ZXDIN 175 Adder #14 1 #4 - # LD2570-ADIN 0LD2570AZXDIN #14 1 #4 - # LD2580-1DIN 0LD25801ZXDIN #14 1 #4 - # LD2580-2DIN 0LD25802ZXDIN #14 1 #4 - # LD2580-3DIN 0LD25803ZXDIN 175 Adder #14 1 #4 - # LD2580-ADIN 0LD2580AZXDIN #14 1 #4 - # LD2970-1DIN 0LD29701ZXDIN #14 1 #4 - # LD2970-2DIN 0LD29702ZXDIN #14 1 #4 - # LD2970-3DIN 0LD29703ZXDIN 175 Adder #14 1 #4 - # LD2970-ADIN 0LD2970AZXDIN =Aluminum, =Copper Hinged Plastic Covers Clear Plastic Covers 3

4 Splicer Block Selection Guide Connector Configuration material Line Load Amp Rating per Pole Wire Range Line Load Outline Drawing Figure Openings per Pole Wire Range Openings per Pole Number =Aluminum, =Copper mcm-# mcm-#6 1 1 LS LS03032Z mcm-# mcm-#6 1 1 LS LS03033Z #2 - #14 1 #2 - # LS LS13001Z #2 - #14 1 #2 - # LS LS13002Z #2 - #14 1 #2 - # LS LS13003Z #2 - #14 1 #2 - # LS LS13004Z # # LS LS21211Z # # LS LS21212Z # # LS LS21213Z #2 - #14 1 #2 - # LS LS25521Z #2 - #14 1 #2 - # LS LS25522Z #2 - #14 1 #2 - # LS LS25523Z # # LS LS25721Z # # LS LS25722Z # # LS LS25723Z mcm-# mcm-#6 1 5 LS LS31231Z mcm-# mcm-#6 1 5 LS LS31232Z mcm-# mcm-#6 1 5 LS LS31233Z mcm-# mcm-#6 1 5 LS LS31241Z mcm-# mcm-#6 1 5 LS LS31242Z mcm-# mcm-#6 1 5 LS LS31243Z mcm-# mcm-#6 1 5 LS LS31261Z mcm-# mcm-#6 1 5 LS LS31262Z mcm-# mcm-#6 1 5 LS LS31263Z mcm-# mcm-#4 1 6 LS LS45571Z mcm-# mcm-#4 1 6 LS LS45572Z mcm-# mcm-#4 1 6 LS LS45573Z mcm-# mcm-#4 2 7 LS LS51291Z mcm-# mcm-#4 2 7 LS LS51292Z mcm-# mcm-#4 2 7 LS LS51293Z mcm-# mcm-#4 2 7 LS LS53011Z mcm-# mcm-#4 2 7 LS LS53012Z mcm-# mcm-#4 2 7 LS LS53013Z # # LS2572-1DIN 0LS25721ZXDIN # # LS2572-2DIN 0LS25722ZXDIN # # LS2572-3DIN 0LS25723ZXDIN 175 Adder # # LS2572-ADIN 0LS2572AZXDIN # # LS2972-1DIN 0LS29721ZXDIN # # LS2972-2DIN 0LS29722ZXDIN # # LS2972-3DIN 0LS29723ZXDIN 175 Adder # # LS2972-ADIN 0LS2972AZXDIN 4

5 dimensions Outline Drawing Figures Dimensions in inches (mm) LX0XXX Figure 1.07" [1.8].218 x.375" [5.5 x 9.5]SLOT.07" [1.8].218 x.375" [5.5 x 9.5]SLOT 2.90" [73.7] 2.90" [73.7] 1.00" [25.4] 1.00" [25.4] 3.52" [89.3] 3.38" [85.8] [104.8].265 x.375" [6.7 x 9.5] SLOT 4.73" 4.63" [118] 5.38" [137].265 x.375" [6.7 x 9.5] SLOT 3.38" [85.8] 2 POLE 3 POLE LX1XXX Figure 2 4-pole LX2XXX Figure 3.31" [7.9] 1.13" [28.6].56" [14].56" [14] 1.94" [49.2].205 [5.2] DIA. HOLE 1.62" [42].63" [16.1] 2.75" [69.9].56" [14] 1.78" [45.2] 2.88" [73.0] 2.25" [57.2] 2.88" [73.0] 2.25" [57.2] 2.88" [73.0] 2.25" [57.2].62" [16].62" [16] 1 POLE 2 POLE 3 POLE Dimensions available at /powr-bloks 5

6 dimensions Outline Drawing Figures Dimensions in inches (mm) LX2XXX-XDIN Figure [61.5] Adder LX3XXX Figure 5 Dimensions available at /powr-bloks 6

7 dimensions Outline Drawing Figures Dimensions in inches (mm) LX4XXX Figure ".31" [57.9] [7.9].31" 1.14" [7.9] [29.0] 1.14" [29.0] 4.16" [106] 1.88" [47.8].31" [7.9] 1.14" [29.0] 6.04" [153] 1.88" 1.88" [47.8] [47.8] 2.92 [74.0] [105] [105] [105] 1 POLE 2 POLE 3 POLE LX5XXX Figure " [40.2] 3.17" [80.4] 1.58" [40.2] 2.69" [68.2] 5.88" [149] 1.58" [40.2] 2.69" [68.2] 8.54" [217] 2.30" [58.5] 3.12" [79.2] 5.50" [140] 5.50" [140] 5.50" [140].37" (9.5).37" [9.5].37" [9.5] 1 POLE 2 POLE 3 POLE Dimensions available at /powr-bloks 7

POWR-BLOKS Distribution/Splicer Blocks and Covers

POWR-BLOKS Distribution/Splicer Blocks and Covers SPECIFICATIONS Voltage : 600V erage: Based on NEC Table 310-16, using 75 C copper wire Material: Phenolic rated at 150 C and Thermoplastic rated at 125 C (LD1400 and LS1300 series only) : Standard: Highly

More information

POWR-BLOKS GUIDE TO DISTRIBUTION BLOCKS WITH HIGH SHORT-CIRCUIT CURRENT RATINGS (SCCR)

POWR-BLOKS GUIDE TO DISTRIBUTION BLOCKS WITH HIGH SHORT-CIRCUIT CURRENT RATINGS (SCCR) POWR-BLOKS TM GUIDE TO S WITH HIGH SHORT-CIRCUIT CURRENT RATINGS (SCCR) REQUIRED (Kcmil/AWG) (2) CLASS / SERIES / MAX AMP RATING (3) CCMR, KLDR IN RMS SYM AMPS (1) LS1300-1 1 LS1300-2 2 115 (1) 2-14 (1)

More information

C-Line Electrical Connectors

C-Line Electrical Connectors C-Line Electrical Connectors Product Catalog (417) 532-7121 PO Box 908 722 Durham Rd Lebanon, MO 65536 Manufactured by: PO Box 908 722 Durham Rd Lebanon, MO 65536 Company Information C-Line Electrical

More information

The accuracy and safety of the connected measuring devices are directly regulated. of the introduced current transformers.

The accuracy and safety of the connected measuring devices are directly regulated. of the introduced current transformers. Product family Current transformers Current transformers (CTs) are introduced where it is difficult to access a direct measuring ot network current. Current transformer transforms the high network current

More information

Miniature controls. Contactors. Overload relays. Starters. Control relays

Miniature controls. Contactors. Overload relays. Starters. Control relays Contactors Overload relays Starters Control relays Description General features Wiring terminations available include plugon connectors, wire pins for PC board mounting and solder connections Low power

More information

Socket P2RF-05-S P2RF-08-S Clip & Release Lever Nameplate R99-11

Socket P2RF-05-S P2RF-08-S Clip & Release Lever Nameplate R99-11 Screwless Clamp Terminal Socket P2RF@@S Screwless clamping greatly contributes to reducing wiring time. No over or under tightening of cable connection so better contact reliability is achieved. Double

More information

PAGE INDEX PAGE # CATALOG NUMBER BUS SUPPORTS B 1 AWSTFR BUS SUPPORTS B 2 AWTTFR BUS SUPPORTS B 3 AWTESR BUS SUPPORTS B 4 AWLI BUS SUPPORTS B 6 AACB

PAGE INDEX PAGE # CATALOG NUMBER BUS SUPPORTS B 1 AWSTFR BUS SUPPORTS B 2 AWTTFR BUS SUPPORTS B 3 AWTESR BUS SUPPORTS B 4 AWLI BUS SUPPORTS B 6 AACB PAGE INDEX ABS ABS (2) ATSBS ABR AIWBS AUAB UAS AABS AAS AL ALS ATCF ATCC CL BTCF RS APT ALC AV ALT ALT (N) ATCF U AWCF AW2CF AWTT AWTT 15 AWTT2 AWST DESCRIPTION MULTI RANGE SINGLE CABLE MULTI RANGE DOUBLE

More information

GENERAL APPLICATION NOTES

GENERAL APPLICATION NOTES GENERAL APPLICATION NOTES There are common considerations when using our connectors. Additional considerations may apply based on the particular connector being used, the application, and conditions in

More information

OTL Universal terminals

OTL Universal terminals OTL Universal terminals 2019 Universal terminals OTL Universal terminals OTL 1000 V AC/DC Bimetal (AL/CU) Class A Certified according to standards EN 612381 and EN 6094771 2 Universal terminals OTL Universal

More information

M8, M12, M18, M30 Cube 40 x 40 mm. 2 mm 15 mm 2 mm 15 mm 20 mm 40 mm

M8, M12, M18, M30 Cube 40 x 40 mm. 2 mm 15 mm 2 mm 15 mm 20 mm 40 mm Bulletin 872C, 871TM, 871FM, 871C, 871P Product Line Overview Proximity Sensors (872C, 871TM, 871FM) 6 / 2011 Features Bulletin 872C 871TM 871P Size Sensing Range Standard Sensing Range Extended Sensing

More information

ACCESSORIES. Standard packing

ACCESSORIES. Standard packing ACCESSORIES HC RELAYS (Sockets and Terminal ) FEATURES. HC Relay Sockets In the table below, the suitable for each type of HC relay is indicated by a black dot. ) Plug-in type, type, and wrapping type

More information

PRODUCT SPECIFICATION

PRODUCT SPECIFICATION MINI-FIT SR. SERIES 1.0 SCOPE This specification covers the 10.00 mm / (.394 in.) centerline tin and gold plated connector series, single and dual row versions in wire to wire and wire to printed circuit

More information

MaxSB - Low Voltage Switchboard

MaxSB - Low Voltage Switchboard BU 3101 Low Voltage Systems, March 2009 Low Voltage Systems MaxSB - Low Voltage Switchboard May 5, 2009 Slide 1 MaxSB Product Overview Description Value Rated Main bus current 1600A, 2000A, 3000A, 3200A,

More information

Primary Terminals & Connectors

Primary Terminals & Connectors Primary & Pure electrolytic copper with electro-tin plating for corrosion resistance Deep internal serrations promote firm wire grip for maximum strength Insulation (where applicable) is color coded to

More information

EPIC Rectangular Connector Inserts. HBE Series. Technical Data Number of Contacts:

EPIC Rectangular Connector Inserts. HBE Series. Technical Data Number of Contacts: HBE Series HBE series inserts provide reliable termination and performance in the vast majority of medium power and control applications. Methods of termination include screw, crimp, and spring cage clamp.

More information

Electrical Contractor s. Labor Units Manual

Electrical Contractor s. Labor Units Manual Electrical Contractor s Labor Units Manual EMT CONDUIT & CONNECTORS EMT THINWALL CONDUIT 1/2" 2.75 3.25 3.75 4.13 4.54 C 3/4" 3.00 3.50 4.00 4.40 4.84 C 1" 3.50 4.00 4.50 4.95 5.45 C 1 1/4" 4.00 4.50 5.00

More information

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure General-purpose Limit Switch CSM_DA-_N_DS_E The Limit Switch with Better Seal, Shock Resistance, and Strength A double seal on the head, a complete gasket cover, and other features ensure a better seal

More information

Florida Building Code 6 th Edition (2017) Residential. Broward County Edition Loose-leaf Supplement

Florida Building Code 6 th Edition (2017) Residential. Broward County Edition Loose-leaf Supplement Board of Rules and Appeals FBC 6 th Edition (2017)- Residential - Supplement No. 1 January 1, 2018 Florida Building Code 6 th Edition (2017) Residential File removed pages for reference. Broward County

More information

Nonmetallic T&B Surface Raceway

Nonmetallic T&B Surface Raceway Nonmetallic Two-Piece System Office White The T&B Two-Piece system is designed to contain everything from THHN conductors to coaxial cable. Made of UL listed 94V-0 PVC, T&B Nonmetallic Surface Raceway

More information

EPIC Rectangular Connectors HBE Series

EPIC Rectangular Connectors HBE Series HBE Series The HBE series inserts are suitable for applications with high voltages and current. The inserts can be terminated in a variety of ways: screw, crimp, or spring cage clamp. TECHNICAL DATA Number

More information

CABLE CONNECTORS CABLE CONNECTORS

CABLE CONNECTORS CABLE CONNECTORS Terminal blocks Terminal blocks E-loks... 4 Multipolar terminal strips... 49 Protected distribution terminals E-Rail... 50 Preinsulated terminals Preinsulated copper terminals... 53 Preinsulated end-sleeve

More information

References 6 k thermal overload relays, adjustable from 0.11 to 16 A

References 6 k thermal overload relays, adjustable from 0.11 to 16 A s 6 k thermal overload relays, adjustable from 0.11 to 16 A 3-pole relays with screw clamp terminals These overload relays are designed for the protection of motors. They are compensated and phase failure

More information

Check with local zoning official for property line distance requirements.

Check with local zoning official for property line distance requirements. RESIDENTIAL POOL PLAN SUBMITTAL GUIDELINES The following guidelines are intended to assist municipal residents with the permit acquisition process with regard to pools, spas and hot tubs for single family

More information

COOPER POWER SERIES. 200 A 15/25 kv class deadbreak straight connector installation instructions. Deadbreak Apparatus Connectors MN650043EN

COOPER POWER SERIES. 200 A 15/25 kv class deadbreak straight connector installation instructions. Deadbreak Apparatus Connectors MN650043EN Deadbreak Apparatus Connectors MN650043EN Effective February 2017 Supersedes October 2004 (S550-12-1) 200 A 15/25 kv class deadbreak straight connector installation instructions COOPER POWER SERIES DISCLAIMER

More information

DT400/436 Tee Connector Installation Instructions

DT400/436 Tee Connector Installation Instructions Connectors Lorem ipsum and dolor Splices sit Amat Effective September 2014 Supersedes IS550-30-1 March 2011 MN650001EN DT400/436 Tee Connector Installation Instructions DISCLAIMER OF WARRANTIES AND LIMITATION

More information

ServicePlus S21R & S27R Series 2 Installation Instructions

ServicePlus S21R & S27R Series 2 Installation Instructions ServicePlus S21R & S27R Series 2 Installation Instructions Horstmann Controls ServicePlus two channel service interval programmers have been developed to facilitate compliance with the Gas Safety (Installation

More information

Operating Instructions

Operating Instructions Operating Instructions Ex d Enclosures in Light Metal / Flameproof Encapsulation > 8265/0 Empty Enclosure > 8265/4 controller, installed in Ex e enclosure > 8265/5 controller Contents 1 Contents 1 Contents...2

More information

Operating Instructions

Operating Instructions Operating Instructions Light-metal Ex d enclosures / flameproof enclosure > 8265/0 Empty enclosure > 8265/4 Control panel, integrated in Ex e enclosure > 8265/5 Control panel Table of Contents 1 Table

More information

Ground Fault Circuit Interrupter(GFCI) Policy

Ground Fault Circuit Interrupter(GFCI) Policy NewStar Netronics, LLC American Products for the World Ground Fault Circuit Interrupter(GFCI) Policy 3926 East 3 rd Street Tulsa, OK 74112 Phone (918)894-5006 Fax (918)836-9909 tech@newstarnetronics.com

More information

Preferred Instruments Danbury, CT USA

Preferred Instruments Danbury, CT USA Tank Level Sensor Model TG-EL-WF-xx Installation & Operation Instructions SDI-TG-EL-WF March 6, 2006 Preferred Instruments Danbury, CT USA www.preferredinstruments.com CONTENTS Installation Pg. 2 Calibration

More information

Security and confidence at height.

Security and confidence at height. A Security and confidence at height. Vertical Systems DISTRIBUTED BY M DBI-SALA Vertical Systems are designed to complement your ability to work while meeting all applicable OSHA and ANSI standards. Vertical

More information

Position switches FP series

Position switches FP series A Position switches FP series Selection diagram 0 08 8 9 0 0 0 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fiber glass rod gasket sphere sphere adjustable lever safety adjustable lever

More information

Differential pressure controls, Type MP 54, 55 and 55A

Differential pressure controls, Type MP 54, 55 and 55A MAKING MODERN LIVING POSSIBLE Technical brochure Differential pressure controls, Type MP 54, 55 and 55A MP 54 and oil pressure controls are used as safety switches to protect refrigeration compressors

More information

Meta-MEC Manual Motor Starters

Meta-MEC Manual Motor Starters www.lsis.biz Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 45 mm 70 mm 63AF 100AF 3 LS Meta-MEC Manual Motor Starters deliver more

More information

DEH Instructions. Three-Phase, Platform-Mounted Distribution Transformers

DEH Instructions. Three-Phase, Platform-Mounted Distribution Transformers g DEH 40050 Instructions Three-Phase, Platform-Mounted Distribution Transformers Introduction The equipment covered by these instructions should be operated and serviced only by competent technicians familiar

More information

Product Safety and the use of EMC techniques to evaluate the 30 Amp Ground continuity test

Product Safety and the use of EMC techniques to evaluate the 30 Amp Ground continuity test Product Safety and the use of EMC techniques to evaluate the 30 Amp Ground continuity test Ron Duffy Product Safety Engineer Agilent Technologies, Inc ron_duffy@agilent.com Richard Georgerian Product Compliance

More information

YSLY-JZ YSLY-OZ. Low voltage - Energy, cabling, signalling and control

YSLY-JZ YSLY-OZ. Low voltage - Energy, cabling, signalling and control Low voltage - Energy, cabling, signalling and control YSLY-JZ YSLY-OZ Construction: VDE Reg. n 7509 according to VDE 0281 Teil 13 according to DIN EN 50525-2-51 Flame propagation: DIN EN 60332-1-2 Low

More information

Type MMV Medium Power Cable

Type MMV Medium Power Cable 7-05 Type MMV Medium Power Cable Single Conductor: 5kV 5kV, 00% & % Insulation Levels. Rated 90 C Multi-Conductor: 5kV 5kV, 00% & % Insulation Levels. Rated 90 C Conductors Soft annealed flexible stranded

More information

I.H.S INSTALLATION INSTRUCTIONS

I.H.S INSTALLATION INSTRUCTIONS I.H.S INSTALLATION INSTRUCTIONS TOOLS REQUIRED The following tools will be required for installation of your I.H.S. system. Item Qty Needed 9/16 Open End Wrench 2 3/4 Open End Wrench 1 1/2 Open End Wrench

More information

Aluminum Mechanical Lugs Dual Rated - One Conductor

Aluminum Mechanical Lugs Dual Rated - One Conductor Dual Rated - One Conductor TA Chamfered wire entry Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 TA-6-S 1 4-14 1/4 17/64 11/16 1-1/16 1/4 1/2 3/32 1/2 41/64 S TA-2 1 One: 2-14 1/4 17/64 11/16 1-5/32 5/16 1/2

More information

General Requirements of the NEC Advanced Course. Building Officials and Inspectors Educational Association

General Requirements of the NEC Advanced Course. Building Officials and Inspectors Educational Association General Requirements of the NEC Advanced Course Building Officials and Inspectors Educational Association General Requirements -NEC Course Outcome Explain general requirements found in Article 110 of the

More information

Introduction. P r otective Seals Panel seal for One Hole Mounting (OHM) O-Ring seals for panel mounting Switch boots

Introduction. P r otective Seals Panel seal for One Hole Mounting (OHM) O-Ring seals for panel mounting Switch boots SECTION F Introduction ACCESSORIES Switch Guar d s Prevent accidental operation of switches Switch operation limited to selected functions Adaptable to one, two and four pole config u r a t i o n s One

More information

Amphenol. PowerLink Solar Cables. Amphenol 97 Series Connectors are UL recognized and CSA recognized.

Amphenol. PowerLink Solar Cables.   Amphenol 97 Series Connectors are UL recognized and CSA recognized. Amphenol PowerLink Solar Cables www.amphenol-industrial.com Amphenol 97 Series Connectors are UL recognized and CSA recognized. PowerLink Solar Cables Amphenol s single conductor PowerLink Solar Cables

More information

S Surge Arresters

S Surge Arresters Surge Arresters UltraSIL Polymer-Housed VariSTAR Type US, UH, and UX Station-Class Surge Arresters Installation and Maintenance Instructions Service Information S235-88-1 Contents Product Information...........................1

More information

SPECIFICATIONS CAPACITY

SPECIFICATIONS CAPACITY DMV-ZRD(LE)/6 SERIES Installation Instructions SPECIFICATIONS DMV-ZRD/6 DMV-ZRDLE/6 Two normally closed safety shutoff valves in one housing. V1 and V2 are fast opening, fast closing. Two stage and adjustable

More information

2-Phase Filters(Direct IEC Connector) RoHS. 250V AC 50/60Hz 1,2,3,6,10A KC, UL, CSA, VDE+ENEC, TÜV, CQC, 25 / 85 / 21

2-Phase Filters(Direct IEC Connector) RoHS. 250V AC 50/60Hz 1,2,3,6,10A KC, UL, CSA, VDE+ENEC, TÜV, CQC, 25 / 85 / 21 2-Phase Filters(Direct IEC Connector) IG IM IL IX ID Rated Voltage/ Frequency 1,2,3,6,10A KC, UL, CSA, VDE+ENEC, TÜV, CQC, Climatic Category IG, IX, ID : IM, IL : Plastic Case IG, IX, ID : Screw and PCB

More information

F series Foot Switches

F series Foot Switches F series Foot Switches ITC presents a complete line of foot switches from Bernstein, designed to respond to the most stringent requirements for machine control and safety applications. The F series includes

More information

will not support combustion

will not support combustion Strain Relief Grips Operating Temperatures Material Temperature Range Aluminum 40 C to +149 C ( 40 F to +300 F) Aluminum deluxe cord grips 34 C to +115 C ( 30 F to +240 F) Non-metallic deluxe cord grips

More information

CLASS CC/CD CCMR SERIES FUSES

CLASS CC/CD CCMR SERIES FUSES 0 Vac Dual Element Time-Delay / - A Description The CCMR series is ideal for space saving protection of motors up to hp*. It was designed specifically to withstand sustained starting currents of small

More information

THE BEST SELECTION OF QUALITY TWIST-ON WIRE CONNECTORS UNDER ONE BRAND

THE BEST SELECTION OF QUALITY TWIST-ON WIRE CONNECTORS UNDER ONE BRAND THE BEST SELECTION OF QUALITY TWIST-ON WIRE CONNECTORS UNDER ONE BRAND History since 1914 2 Packaging Choices 3 NE W 833 Wide Range / Ergonomic Compact Design 4 Marrette XTP 6 Marrette Type II Winged 8

More information

Size Selection & Installation of QSZH-125

Size Selection & Installation of QSZH-125 Product Installation Procedure (PIP) No: PIP-101 Revision: 2 Dated: January 2012 Title:- Size Selection & Installation of QSZH-125 Prepared By: Name: Clive Benning Date: January 2012 Reviewed & Approved

More information

CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES

CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES I N S T R U C T I O N - M A N U A L CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES FUNCTION: Conductivity level limit switches are based on the principle of measuring level through the electrical

More information

Pressure controls for hydro carbons, zone II applications, Type KPE

Pressure controls for hydro carbons, zone II applications, Type KPE MAKING MODERN LIVING POSSIBLE Technical brochure Pressure controls for hydro carbons, zone II applications, Type KPE KPE pressure controls for use in refrigeration and air conditioning systems with hydrocarbons

More information

Wire Buddy Manual IOpath Software

Wire Buddy Manual IOpath Software Wire Buddy Manual IOpath Software Wire Buddy is a calculation reference tool for Electricians and Maintenance personnel. Wire Buddy was created for the Maintenance Electrician. There are many occasions

More information

Copper Bonded Ground Rod / Grounding Rods / Copper Bonded Earth Rod / Earthing rods

Copper Bonded Ground Rod / Grounding Rods / Copper Bonded Earth Rod / Earthing rods Copper Bonded Ground Rod / Grounding Rods / Copper Bonded Earth Rod / Earthing rods Copper bonded earth rods are made from low carbon Steel. Earth Rods are molecularly bonded with 99.9% pure electrolytic

More information

Cycling Device Training Manual

Cycling Device Training Manual NRG POWER, INC. Industrial Electrical Contractors NRG POWER, INC. Phone: 714.424.6484 Industrial Electrical Contractors Fax: 714.424.6477 3011 South Shannon Street email: nrgpower@yahoo.com Santa Ana,

More information

Class CC/CD CCMR Series FUSES

Class CC/CD CCMR Series FUSES 0 VAC Dual Element Time-Delay / - A Description The CCMR series is ideal for space saving protection of motors up to hp*. It was designed specifically to withstand sustained starting currents of small

More information

A28 Series Two-Stage Temperature Controls with NEMA 1 Enclosure

A28 Series Two-Stage Temperature Controls with NEMA 1 Enclosure Master Catalog 125 Temperature Controls Section A Product Bulletin A28 Issue Date 0618 A28 Series Two-Stage Temperature Controls with NEMA 1 Enclosure Application These two-stage controls are designed

More information

North American Pressure Switches

North American Pressure Switches Combustion North American Pressure Switches Bulletin 8757 Pressure switches are used with Automatic Shutoff Valves or Solenoid Valves to interrupt fuel flow in the event of fuel or air failure. They are

More information

Selection of Electrical PPE Tables

Selection of Electrical PPE Tables Selection of Electrical PPE Tables Instructions Table 1 - Starting with Table 1, select the task you plan to do (right-hand column) and the condition of the equipment you will be working on, (center column).

More information

TeSys protection components

TeSys protection components Presentation, description -pole thermal overload relays TeSys D Presentation TeSys D thermal overload relays are designed to protect a.c. circuits and motors against: b overloads, b phase failure, b excessively

More information

Safe Schools: A Health and Safety Check

Safe Schools: A Health and Safety Check Name of School: Optional Information Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: Use of Electrical Equipment Self-Inspection Checklist Guidelines: This checklist covers

More information

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119 Pressure switch type CS December 2001 DKACT.PD.P10.A2.02 520B1119 Introduction Pressure switch type CS is part of the Danfoss pressure control range. All CS pressure switches have a built-in pressure-operated,

More information

Differential pressure switch / Lube oil protection control MP 54 and MP 55

Differential pressure switch / Lube oil protection control MP 54 and MP 55 Data sheet Differential pressure switch / Lube oil protection control MP 54 and MP 55 MP 54 and MP 55 oil differential pressure switches are used as safety switches to protect refrigeration compressors

More information

Differential Pressure Control Types MP 54, MP 55 and MP 55A

Differential Pressure Control Types MP 54, MP 55 and MP 55A MAKING MODERN LIVING POSSIBLE Data sheet Differential Pressure Control Types MP 54, MP 55 and MP 55A MP 54 and MP 55 oil differential pressure controls are used as safety switches to protect refrigeration

More information

Zelio Relays RSL Slim Interface Plug-In Relays

Zelio Relays RSL Slim Interface Plug-In Relays Zelio Relays RSL Slim Interface Plug-In Relays Catalog 8501CT0901 2009 Class 8501 CONTENTS Description............................................. Page Introduction.................................................3

More information

TERMINAL BLOCK SUMMARY

TERMINAL BLOCK SUMMARY TERMINAL BLOCK SUMMARY TERMINAL BLOCK SUMMARY TERMINAL BLOCK SUMMARY FEEDTHROUGH TERMINALS FUSE TERMINALS DISCONNECT TERMINALS MICRO TERMINALS CIRCUIT BREAKERS PRODUCT INFORMATION Feedthrough Terminals

More information

COOPER POWER SERIES. 50 A 2:1 series multiple (dual voltage) switch cap/wrench, lever or hotstick operable handles installation instructions

COOPER POWER SERIES. 50 A 2:1 series multiple (dual voltage) switch cap/wrench, lever or hotstick operable handles installation instructions Voltage Regulators MN800013EN Effective February 2016 Supersedes S800-70-1 August 2012 COOPER POWER SERIES 50 A 2:1 series multiple (dual voltage) switch cap/wrench, lever or hotstick operable handles

More information

PRESSURE SWITCHES Bulletin 8757

PRESSURE SWITCHES Bulletin 8757 PRESSURE SWITCHES Bulletin 8757 September 2013 Pressure switches are used with Automatic Shutoff Valves or solenoid valves to interrupt fuel fl ow in the event of fuel or air failure. They are also used

More information

PUR cable. PUR cable. The harmonised version H05BQ-F/H07BQ-F can be used at building construction areas and where HAR-approval is required in Europe.

PUR cable. PUR cable. The harmonised version H05BQ-F/H07BQ-F can be used at building construction areas and where HAR-approval is required in Europe. Polyurethan (PUR) cables are suitable as control cables, for fl exible use where high mechanical stress occurs. The PUR outer jacket has very good resistance against mineral oils and different chemical

More information

Differential pressure switch MP 54, MP 55 and MP 55A

Differential pressure switch MP 54, MP 55 and MP 55A Data sheet Differential pressure switch MP 54, MP 55 and MP 55A MP 54 and MP 55 oil differential pressure switches are used as safety switches to protect refrigeration compressors against low lubricating

More information

How to terminate an F/UTP CAT 6 cable with the LP-LRJ458P8CC6FS21 Plug.

How to terminate an F/UTP CAT 6 cable with the LP-LRJ458P8CC6FS21 Plug. Cabling Systems - Copper Solutions How to terminate an F/UTP CAT 6 cable with the LP-LRJ458P8CC6FS21 Plug. LPLRJ458P8CC6FS21_M123_ENB01W How to terminate an F/UTP CAT 6 cable with the LP-LRJ458P8CC6FS21

More information

Die Cast Aluminum Conduit Outlet Bodies, Covers & Gaskets

Die Cast Aluminum Conduit Outlet Bodies, Covers & Gaskets Covers & s die cast copper-free aluminum conduit bodies, covers and gaskets are available for use with rigid or EMT conduit (with set screw). Conduit bodies are available in trade sizes /2 to 4, in the

More information

Ground Fault Protection for Electrical Tools

Ground Fault Protection for Electrical Tools Hanover Risk Solutions Ground Fault Protection for Electrical Tools Effective electrical tool and equipment grounding are extremely important on construction sites. Injuries and deaths can result from

More information

Installation Instructions for the Walking Beam Interlock for Eaton EHD, FDB, FD, HFD, FDC, FW, HFW, FWC, Circuit Breakers and Molded Case Switches

Installation Instructions for the Walking Beam Interlock for Eaton EHD, FDB, FD, HFD, FDC, FW, HFW, FWC, Circuit Breakers and Molded Case Switches Supersedes IL 29C300B Dated 12/97 Contents Description Page Introduction.... 2 Installation.... 3 WARNING DO NOT ATTEMPT TO INSTALL OR PERFORM MAIN- TENANCE ON EQUIPMENT WHILE IT IS ENERGIZED. DEATH, SEVERE

More information

Monitoring device NTS 30

Monitoring device NTS 30 P R O D U C T I N F O R M A T I O N Electronic level- and temperature monitoring device Monitoring device NTS 30 Contents Description Description... 2 Operating... 3 Design and electrical data... 4 Circuit

More information

PANDUIT Copper Compression Metric Lugs and Splices

PANDUIT Copper Compression Metric Lugs and Splices Compression etric ugs and Splices Optimum reliability and safety With etric s Worldwide availability RoHS compliant Class 2R rigid stranded conductor sizes 4mm 2 630mm 2 Key Features and enefits Two-Hole

More information

Sub-Base Assembly For Type-ML 32 & VR-1 Step Voltage Regulator Single-Phase Liquid-Filled Part # GEK 35171

Sub-Base Assembly For Type-ML 32 & VR-1 Step Voltage Regulator Single-Phase Liquid-Filled Part # GEK 35171 Transformer Business Department Regulator & Inductive Products Sub-Base Assembly For Type-ML 32 & VR-1 Step Voltage Regulator Single-Phase Liquid-Filled Part # GEK 35171 Last Update 11-19-2013 Tom Dauzat,

More information

UHF/Mini-UHF Coaxial Connectors

UHF/Mini-UHF Coaxial Connectors UHF/MiniUHF Coaxial Connectors The Amphenol UHF/MINIUHF connectors are popular and economical, used when impedance mating is not required. General purpose units are designed to operate satisfactorily op

More information

REMKE STYLE PowR-TECK CONNECTORS

REMKE STYLE PowR-TECK CONNECTORS REMKE STYLE PowR-TECK CONNECTORS CONNECTORS FOR JACKETED TECK CABLE Your LEAD BRAND in the changing market EXPERIENCE THE POWR OF A ONE PIECE DESIGN COMPRESSION RING Downward pressure ensures uniform compression

More information

SPECIFICATIONS ATTENTION

SPECIFICATIONS ATTENTION VPS 504 S06 Installation Manual - P/N 80122 - Ed. 01/09 VPS 504 S06 and S05 Valve Proving System Installation Instructions VPS 1 6 Gases Natural gas, air and other inert gases. NOT suitable for butane

More information

FEATURES & BENEFITS. Prewired Raceway is prewired and packed to the job specifications at the factory before shipping to the jobsite.

FEATURES & BENEFITS. Prewired Raceway is prewired and packed to the job specifications at the factory before shipping to the jobsite. Prewired Two-Piece Surface Raceway WIREMOLD Aluminum Raceway Isoduct AL4000 Series Raceway is a two-channel, single-cover, highly aesthetic, raceway solution designed to provide access to communication

More information

ECP Series Explosionproof Enclosures for OEM Applications. Optimized design, extensive sizes, and fast lead times.

ECP Series Explosionproof Enclosures for OEM Applications. Optimized design, extensive sizes, and fast lead times. ECP Series Explosionproof Enclosures for OEM Applications Optimized design, extensive sizes, and fast lead times. ECP Series Explosionproof Enclosures, the latest addition to our portfolio of electrical

More information

PART I. GENERAL REQUIREMENTS FOR PERMANENTLY INSTALLED POOLS, STORABLE POOLS, OUTDOOR SPAS, OUTDOOR HOT TUBS, OR FOUNTAINS

PART I. GENERAL REQUIREMENTS FOR PERMANENTLY INSTALLED POOLS, STORABLE POOLS, OUTDOOR SPAS, OUTDOOR HOT TUBS, OR FOUNTAINS The overriding concern of Article 680 is to keep people and electricity separated. Some ways in which Article 680 accomplishes this include: References to other articles. Equipment Requirements. Any equipment

More information

LECTRAFLEX CABLE AND WIRE. 46 Concentric jacketing provides consistent abrasion resistance

LECTRAFLEX CABLE AND WIRE. 46  Concentric jacketing provides consistent abrasion resistance Concentric jacketing provides consistent abrasion resistance Paper wrapped for ease of stripping* UV protected jacketing resists magnesium and calcium chlorides and other chemicals* Excellent abrasion

More information

Item No.: /

Item No.: / mounting types; for parallel or perpendicular mounting; pin spacing mm / 0197 in; 4-pole - Item No: 769- Male connector; with CAGE CLAMP connection and fixing flanges; for screw or similar mounting types;

More information

Pressure switch KP-E. Data sheet

Pressure switch KP-E. Data sheet Data sheet Pressure switch KP-E KP-E pressure switches for use in refrigeration and air conditioning systems are equipped with SPDT gold plated contacts and stainless steel bellows. The high pressure switches

More information

*NOTE: 75 OHM SERIES CONNECTORS ARE NOT INTERMATEABLE WITH THE 50 OHM SERIES.

*NOTE: 75 OHM SERIES CONNECTORS ARE NOT INTERMATEABLE WITH THE 50 OHM SERIES. The Connex N connectors with screw coupling are fully interchangeable with N connectors made to the MIL-C-39012 specification. Designed for use in all systems where very good R.F. and mechanical performance

More information

FMU4X, FMC4X FMU4P, FMC4P

FMU4X, FMC4X FMU4P, FMC4P ENVIRONMENTALLY SOUND REFRIGERANT FMU4X, FMC4X FMU4P, FMC4P Product Specifications HORIZONTAL FAN COILS FMU4P and FMC4P 1 1/2, 2, 2 1/2, and 3 Tons FMU4X and FMC4X 1 1/2, 2 and 2 1/2 Tons ALL MODELS Horizontal

More information

Differential pressure controls/ Lube oil protection controls MP 54 and MP 55 REFRIGERATION AND AIR CONDITIONING. Technical leafl et

Differential pressure controls/ Lube oil protection controls MP 54 and MP 55 REFRIGERATION AND AIR CONDITIONING. Technical leafl et Differential pressure controls/ Lube oil protection controls MP 54 and MP 55 REFRIGERATION AND AIR CONDITIONING Technical leafl et Contents Page Introduction... 3 Features... 3 Approvals... 3 Materials

More information

MV-105 MEDIUM VOLTAGE CABLE. 5kV, 8kV, 15kV, 25kV & 35kV

MV-105 MEDIUM VOLTAGE CABLE. 5kV, 8kV, 15kV, 25kV & 35kV MV-05 MEDIUM VOLTAGE CABLE 5kV, 8kV, 5kV, 5kV & 5kV MV-05 MEDIUM VOLTAGE POWER CABLE 5kV % INSULATION LEVEL 8kV 00% INSULATION LEVEL Conductor conforming to ASTM B and Class B Compact stranded in accordance

More information

COOPER POWER SERIES. DS250 deadbreak straight connector installation instructions interface A. Connectors MN650027EN

COOPER POWER SERIES. DS250 deadbreak straight connector installation instructions interface A. Connectors MN650027EN Connectors MN650027EN Effective November 2016 Supersedes January 2014 (IS550-11-1) DS250 deadbreak straight connector installation instructions interface A COOPER POWER SERIES DISCLAIMER OF WARRANTIES

More information

Electrical. OSHA Office of Training and Education 1

Electrical. OSHA Office of Training and Education 1 Electrical OSHA Office of Training and Education 1 Introduction An average of one worker is electrocuted on the job every day There are four main types of electrical injuries: Electrocution (death due

More information

D. ACCESSORIES ADAPTER KITS IMPELLER & SEAL INSTALLATION TOOLS CARRYING HANDLES & LIFT CORDS GALVANIC PROTECTION KITS MUSHROOM STRAINER

D. ACCESSORIES ADAPTER KITS IMPELLER & SEAL INSTALLATION TOOLS CARRYING HANDLES & LIFT CORDS GALVANIC PROTECTION KITS MUSHROOM STRAINER . ACCESSORIES AAPTER KITS IMPELLER & SEAL INSTALLATION TOOLS CARRYING HANLES & LIFT CORS GALVANIC PROTECTION KITS MUSHROOM STRAINER SLUGE STRAINERS NEMA 4 WATERTIGHT CONTROL & UAL LEVEL CONTROL (Replaces

More information

Residential Swimming pools

Residential Swimming pools City of Republic Community Development Department Residential Swimming pools REVISION DATE: JANUARY 2017 Swimming Pool Safety Definitions: Barrier Requirements: A) Application All swimming pools over 24

More information

44 CE RANGE WATERTIGHT SURFACE-MOUNTING JUNCTION BOXES

44 CE RANGE WATERTIGHT SURFACE-MOUNTING JUNCTION BOXES WALL BOXES IN GWPLAST 75 - GWT 650 C GWT 650 C TP 85 C WALLS WITH CABLE GLAND - IP44 AND IP55 GW44001 JUNCTION BOXES WITH PLAIN PRESS-ON LID - IP44 - GREY RAL 7035 LxHxD (mm) No. holes / Ø GW 44 001 Ø

More information

Continental Industries STEEL SERVICE TEES or FAX Visit

Continental Industries STEEL SERVICE TEES or FAX Visit Continental Industries STEEL SERVICE TEES 1-800-558-1373 or FAX 1-800-788-1668 Visit www.conind.com ABOUT US Our Company Continental Industries, headquartered in Tulsa, Oklahoma, was formed in 1958 and

More information

Pressure switches for air and water CS

Pressure switches for air and water CS Data sheet Pressure switches for air and water CS CS pressure switches have a built-in pressure operated, three-pole switch. The contact position of which depends on the pressure in the connector and the

More information

COOPER POWER SERIES. DE250 deadbreak elbow connector installation instructions interface A. Screened Separable Connectors MN650025EN

COOPER POWER SERIES. DE250 deadbreak elbow connector installation instructions interface A. Screened Separable Connectors MN650025EN Screened Separable Connectors MN650025EN Effective November 2016 Supersedes September 2013 (IS550-10-1) DE250 deadbreak elbow connector installation instructions interface A COOPER POWER SERIES DISCLAIMER

More information