Réf GB /d ALTERNATORS LSA Pole - Three phase. Electrical and mechanical data

Size: px
Start display at page:

Download "Réf GB /d ALTERNATORS LSA Pole - Three phase. Electrical and mechanical data"

Transcription

1 Réf. 264 GB /d ALTERNATORS LSA Pole - Three phase Electrical and mechanical data

2 TYPICAL DATA ALTERNATORS Hz - 1 r.p.m. Insulation class H Excitation system Shunt A R E P Winding pitch - Code 2/3 - (N 6) A.V.R. model R 2 R 438 Wires 12 Voltage regulation (steady state) ±, % ±, % Drip proof IP 23 Sustained short-circuit current - % (3 IN) : 1s Altitude 1 m Total harmonic (*) TGH / THC < 4 % < 4 % Overspeed 22 min -1 Wave form : NEMA = TIF - (*) < < Air flow,1 m 3 /s Wave form : I.E.C. = THF - (*) < 2 % < 2 % (*) Total harmonic content line to line, at no load or full rated linear and balanced load RATINGS : kva / kw - Power factor =,8 Duty/Ambiant T Continuous / 4 C Stand-by / 4 C Stand-by / 27 C Class/T rise H / 12 K F / 1 K H / 1 K H / 163 K Phase 3 ph. 1 ph. 3 ph. 1 ph. 3 ph. 1 ph. 3 ph. 1 ph. Y 38V 2V 4V 41V 38V 2V 4V 41V 42.2 S4 kva 17, , kw 14 8,8 13, ,6 16, S kva 12, 19, 11, , 2 14,1 kw ,6 9,3 19 1,8 19,8 11, M6 kva , kw 18,4 11,2 16,8 1,4 21, ,4 12, M7 kva , ,2 kw 21,6 12,8 11,9 23,8 13,9 24,8 14, L9 kva 31, 18, 28, 17,1 33,4 3,6 kw 2,2 14, ,7 26,7 1,9 27,8 16, EFFICIENCIES (%) : Class H. 4 C Three phase : 4 V Single phase : 2 V P.F. =,8 P.F. = 1 P.F. =,8 P.F. = 1 1/4 2/4 3/4 4/4 St.by 1/4 2/4 3/4 4/4 St.by 1/4 2/4 3/4 4/4 St.by 1/4 2/4 3/4 4/4 St.by 42.2 S4 82,9 87, ,6 87,2 84,9 9,2 91, 91,6 91, 7,7 81,6 82,2 81,3 8,6 78 8,2 86,9 87,1 86, S 84,2 87,8 87, ,6 86,2 9,8 91,6 91, 91,2 77, ,9 8,4 79,6 79, ,1 86,8 86, 42.2 M6 8 89,2 89,8 89,4 89,1 86,6 91, 92,6 92,8 92, ,9 84,7 84,1 83,7 79,9 86,8 88, 88,7 88, M7 86,4 89,6 89,7 88,9 88, 88,1 92,1 92,8 92,6 92,4 79,6 84,3 84, 83, 82,9 81,6 87, 88,7 88, 88, L9 87,9 9, ,6 89,6 92,8 93,1 92,7 92, 81,7 8,4 8,1 83,7 83,1 83,7 88,6 89,2 88,7 88,4 REACTANCES (%) - TIME CONSTANTS (ms) : CLASS : H / 4 V 42.2 S S 42.2 M M L9 Kcc Short-circuit ratio,76,66,71,6,1 Xd Direct axis synchronous reactance unsaturated Xq Quadrature axis synchronous reactance unsaturated T'do Open circuit time constant X'd Direct axis transient reactance saturated 1,1 11, 9,3 1,9 11,8 T'd Short circuit transient time constant X"d Direct axis subtransient reactance saturated,,8 4,6,,9 T"d Subtransient time constant X"q Quadrature axis subtransient reactance saturated 7,1 8,1 6, 7,7 8,4 Xo Zero sequence reactance unsaturated,8,1,6,2,3 X2 Negative sequence reactance saturated 6, 6,9,6 6,6 7,1 Ta Armature time constant OTHER DATA - CLASS : H / 4 V - io No load excitation current (A) (SHUNT/AREP),6/,9,6/,9,/,8,/,8,/,7 ic Full load excitation current (A) (SHUNT/AREP) 1,4/2,1 1,6/2,3 1,3/2 1,/2,3 1,/2,3 uc Full load excitation voltage (V) (SHUNT/AREP) 36/13 4/14 34/12 39/14 39/14 ms Recovery time( U = % trans.) kva (Shunt) Motor start. ( U = % sust.) or ( U = % Transient) kva (AREP) Motor start. ( U = % sust.) or ( U = % Transient) % Transient dip (rated step load) - PF :,8 LAG 13,6 14,7 13,1 14, 1,6 W No load losses W Heat rejection According to : I.E.C. 34.1/ U.T.E. : NF C V.D.E. - B.S & - NEMA : MG ISO CSA (upon request)... 38V 2V 4V 41V 38V 2V 4V 41V

3 ALTERNATORS Hz - 1 r.p.m. TRANSIENT VOLTAGE VARIATION - 4V % Voltage dip Load application S4 S M6 M7 L9 % Voltage rise Load rejection S4 S M6 M7 L , , kva at,8 power factor 6, kva at,8 power factor 4 Motor starting S4 S M6 M7 L9 % Voltage dip 1 4,9 4,8 3,7 3,6 3,4 1 9,4 9,1 7,1 6,9 6,6 1 13, ,6 17, , , , , Locked rotor - kva at,6 power factor ) For a starting P.F. differing from,6 the starting kva have to be multiplied by (Sine Ø /,8) 2) If voltage is not 4V(Y), ( ) at Hz then kva must be multiplied by (4/ U ) 2 or (2/ U ) 2.

4 TYPICAL DATA ALTERNATORS 6 Hz - 18 r.p.m. Insulation class H Excitation system Shunt A R E P Winding pitch - Code 2/3 - (N 6) A.V.R. model R 2 R 438 Wires 12 Voltage regulation (steady state) ±, % ±, % Drip proof IP 23 Sustained short-circuit current - % (3 IN) : 1s Altitude 1 m Total harmonic (*) TGH / THC < 4 % < 4 % Overspeed 22 min -1 Wave form : NEMA = TIF - (*) < < Air flow,18 m 3 /s Wave form : I.E.C. = THF - (*) < 2 % < 2 % (*) Total harmonic content line to line, at no load or full rated linear and balanced load RATINGS : kva / kw - Power factor =,8 Duty/Ambiant T Continuous / 4 C Stand-by / 4 C Stand-by / 27 C Class/T rise H / 12 K F / 1 K H / 1 K H / 163 K Phase 3 ph. 1 ph. 3 ph. 1 ph. 3 ph. 1 ph. 3 ph. 1 ph. Y 38V 416V 44V 48V 38V 416V 44V 48V 38V 416V 44V 48V 38V 416V 44V 48V Y 8V 2V 8V 2V 8V 2V 8V 2V 42.2 S4 kva , ,1 21,2 21,2 12, ,4 2, ,4 26,4 16,3 kw , ,3, ,, S kva ,6 21, 24,6 2 2, ,7,1,1 16,9 26,7 31, 31, 17, kw , 17, ,1 24,1 13, 21 24, M6 kva ,7 2 27,3 27, 28,2 16, , 31 34, 3 3, 21,3 kw ,6 13, 23 27,2 27,2 27, , , M7 kva ,9 31,2 31,9 18,8 33 3,8 36,8 37,4 21, , 38,4 39,1 21,9 kw ,7 2 2, ,6 29, ,7 31,3 17, 42.2 L9 kva ,3 33,7 3 3,6 3 39,1 4,4 41,7 22, 36 4, 41,7 43,6 23,8 kw 26 29,, , ,3 32,3 33, ,4 33, EFFICIENCIES (%) : Class H. 4 C Three phase : 48 V Single phase : 24 V P.F. =,8 P.F. = 1 P.F. =,8 P.F. = 1 1/4 2/4 3/4 4/4 St.by 1/4 2/4 3/4 4/4 St.by 1/4 2/4 3/4 4/4 St.by 1/4 2/4 3/4 4/4 St.by 42.2 S4 82, 87,7 88,6 88,4 88,2 84,1 9 91, 91,9 91,9 78,2 83,4 83,6 82, 81,9 8,2 86, 87,7 87, 87, S 84,3 88,2 88,6 87,9 87, 86 9,8 91,8 91,8 91,7 8,2 83, ,2 8,4 82,3 87,2 87,6 86,9 86, M6 8,2 89, 9,2 9 89,7 86,7 91,6 92, ,9 81,3 8,4 8,3 84,1 83, 83,1 88,3 89,1 88,7 88, M ,8 9,2 89,7 89,4 87, 91,9 92,9 92,9 92,8 82 8,6 8,1 83, ,8 88, 89,1 88, 88, L9 87,2 9, 9,7 9 89,7 88,6 92, 93,3 93, ,7 86 8, 84 83,3 84,4 88,9 89,3 88,7 88,3 REACTANCES (%) - TIME CONSTANTS (ms) : CLASS : H / 48 V 42.2 S S 42.2 M M L9 Kcc Short-circuit ratio,72,6,62,7,1 Xd Direct axis synchronous reactance unsaturated Xq Quadrature axis synchronous reactance unsaturated T'do Open circuit time constant X'd Direct axis transient reactance saturated 1,6 12,6 1, 11, 12, T'd Short circuit transient time constant X"d Direct axis subtransient reactance saturated,3 6,3,3,7 6 T"d Subtransient time constant X"q Quadrature axis subtransient reactance saturated 7,4 8,8 7,4 8,1 8,4 Xo Zero sequence reactance unsaturated 1,2,,,6 X2 Negative sequence reactance saturated 6,4 7,6 6,3 6,9 7,2 Ta Armature time constant OTHER DATA - CLASS : H / 48 V - io No load excitation current (A) (SHUNT/AREP),6/,9,6/,9,/,8,/,8,/,7 ic Full load excitation current (A) (SHUNT/AREP) 1,4/2,1 1,6/2,4 1,3/2,1 1,/2,3 1,/2,2 uc Full load excitation voltage (V) (SHUNT/AREP) 36/13 4/1 34/13 39/14 39/14 ms Recovery time( U = % trans.) kva (Shunt) Motor start. ( U = % sust.) or ( U = % Transient) kva (AREP) Motor start. ( U = % sust.) or ( U = % Transient) % Transient dip (rated step load) - PF :,8 LAG 14 1,6 14,2 1 1,7 W No load losses W Heat rejection According to : I.E.C. 34.1/ U.T.E. : NF C V.D.E. - B.S & - NEMA : MG ISO CSA.

5 ALTERNATORS 6 Hz - 18 r.p.m. TRANSIENT VOLTAGE VARIATION - 48 V % Voltage dip Load application S4 S M6 M7 L9 % Voltage rise Load rejection S4 S M6 M7 L kva at,8 power factor kva at,8 power factor 4 Motor starting S4 S M6 M7 L9 % Voltage dip Locked rotor - kva at,6 power factor 1) For a starting P.F. differing from,6 the starting kva have to be multiplied by (Sine Ø /,8) If voltage is not 48V(Y), 277V( ), (YY ) at 6 Hz then kva must be multiplied by (48/ U ) 2 or (277/ U ) 2 or (24/ U ) 2.

6 ALTERNATORS Single bearing DIMENSIONS AH Z 12 Xg L LB Access to regulator Access to terminals Cable output SAE 2, 3, 4 design BT 38 SAE design 11 DIA, XBG Eq. Sp. holes on M P.C.D. Ø P -,127 -, -,1 Ø N Ø BX Ø 3 Ø 31 BH 11 DIA, XBG Sp. as shown holes on M P.C.D. ß Y DIA, X Eq. Sp. holes on U P.C.D ß 44 AIR OUTLET 3 W AIR INLET BL FRAME DIMENSIONS (mm) Mass (kg) TYPE L maxi LB Xg M LSA 42.2 S LSA 42.2 S LSA 42.2 M LSA 42.2 M LSA 42.2 L FLANGE DIMENSIONS (mm) N M XBG W ß S.A.E. 314,32 333, ' S.A.E , S.A.E. 3 49,7 428, S.A.E ,67 466, TORSIONAL ANALYSIS DATA FLANGE FLEX PLATE DIMENSIONS (mm) COUPLING POSSIBILITY P BL BH BT 6 1/2 7 1/ /2 S.A.E S.A.E S.A.E S.A.E S.A.E. BX U X Y AH Z 11 1/2 32,42 333, , ,32 29, , ,2 244, /2 241,3 222,2 8 9,2 6 1/2 21,9,2 6 9,2 Bearing Exciter armature Main field Fan Disc 4 H G K 1 A B 2 C 3 Ø 18 Ø 3 Ø Ø 62 8,8 1,7 D F E Ø 8, 29 Ø 38 Ø 2 19 CENTER OF GRAVITY (mm) MASS : kg / MOMENTS OF INERTIA J : kgm 2, (4J = MD 2 ) (1) (2) (3) (4) TOTAL TYPE Disc A B C D E F G H K M J M J M J M J M J 11 1/2 247,1 436,6 468,1 4, ,3 12 1,4,2,26,,91 4,7,18 2,3,27 37,7, ,3 4,8 482,3 4, , ,6,2,26,,91 4,7,18 1,8,18 37,2,1296 S4/S 8 269, 49 49, 4, ,3 37,8,2,26,,91 4,7,18 1,3,9 36,7,16 7 1/2 237,7 427,2 48,7 4, , 92, 6,2,26,,91 4,7,18 1, 36,4, /2 237,7 427,2 48,7 4, , 92, 6,2,26,,91 4,7,18,8,36 36,3, /2 274,6 491,6 23,7 29, ,3 12 1,4,2,26 41,12 4,7,18 2,3,27 48,2, ,8,8 37,3 29, , ,6,2,26 41,12 4,7,18 1,8,18 47,7,186 M6/M , 29, ,3 37,8,2,26 41,12 4,7,18 1,3,9 47,2, /2 26,2 482,2 13,7 29, , 92, 6,2,26 41,12 4,7,18 1, 46,9, /2 26,2 482,2 13,7 29, , 92, 6,2,26 41,12 4,7,18,8,36 46,8, /2 289,6 21,6 3,1 289, ,3 12 1,4,2,26 48,13 4,7,18 2,3,27,2, ,8 3,8 67,3 289, , ,6,2,26 48,13 4,7,18 1,8,18 4,7,1736 L , 289, ,3 37,8,2,26 48,13 4,7,18 1,3,9 4,2, /2 28,2 12,2 43,7 289, , 92, 6,2,26 48,13 4,7,18 1, 3,9, /2 28,2 12,2 43,7 289, , 92, 6,2,26 48,13 4,7,18,8,36 3,8,192

7 ALTERNATORS Two bearing DIMENSIONS M 16 x Xg L LB Cable output Access to terminals 38 Access to regulator 22 ' Ø 38 Ø 31 Ø 266,7 -,127 +,2 Ø 42 +,9 Ø AIR AIR M1 DIA, 8 Eq. Sp. holes on 28,7 DIA (SAE 6) FRAME DIMENSIONS (mm) Mass (kg) TYPE L maxi LB Xg M LSA 42.2 S LSA 42.2 S LSA 42.2 M LSA 42.2 M LSA 42.2 L TORSIONAL ANALYSIS DATA Bearing Exciter armature Main field Fan 1,8 A B C 2 3 Ø Ø 4 37 Ø 3 7, Ø D E Ø 62 F Ø 8, 29 Ø 38 Ø 2 19 CENTER OF GRAVITY (mm) MASS : kg / MOMENTS OF INERTIA J : kgm 2, (4J = MD 2 ) (1) (2) (3) TOTAL TYPE A B C D E F M J M J M J M J S4 1 39, 422 4, 39 72,2,26,,91 4,7,18 3,4,1116 S 1 39, 422 4, 39 72,2,26,,91 4,7,18 3,4,1116 M6 228, 44, , 94 72,2,26 41,12 4,7,18 4,9,146 M7 228, 44, , 94 72,2,26 41,12 4,7,18 4,9,146 L9 243, 47, 7 289, ,2,26 48,13 4,7,18 2,9,16

8 MOTEURS LEROY-SOMER 161 ANGOULÊME CEDEX - FRANCE RCS ANGOULÊME N B S.A. au capital de F

LSA 42.2 /43.2 / & 4 P

LSA 42.2 /43.2 / & 4 P 3542 en - 9.27 / d Alternators 11.5... 3 kva - 2 Pole 12... 135 kva - 4 Pole SA 42.2 / 43.2 / 44.2-2 & 4 P Single phase dedicated Electrical and mechanical data SA 42.2 /43.2 / 44.2-2 & 4 P Single phase

More information

ASM. Asynchronous Spindle Motors. SEM Limited Faraday Way Orpington, Kent BR5 3QT United Kingdom

ASM. Asynchronous Spindle Motors. SEM Limited Faraday Way Orpington, Kent BR5 3QT United Kingdom NE ASM Asynchronous Spindle Motors SEM Limited Faraday Way Orpington, Kent BR 3QT United Kingdom Tel: +44 ()189 8847 Fax: +44 ()189 884884 Email: sales@sem.co.uk Web: www.sem.co.uk Version 4 August 2 Asynchronous

More information

Limit switches OsiSense XC Special For material handling applications, type XC1 AC

Limit switches OsiSense XC Special For material handling applications, type XC1 AC Presentation For material handling applications, type XC C b XC C with slow break contacts v With head for linear movement () 00_ 00_ 000_ Page / 00_ 00_ XCC XCC Page / XCC XCC / General characteristics

More information

W01 Rolled Steel Fractional Horsepower Motor

W01 Rolled Steel Fractional Horsepower Motor Motors Automation Energy Transmission & Distribution Coatings Fractional Horsepower Motor Technical Catalogue NEMA Market The new generation of WEG general purpose steel motors. The motors of the line

More information

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications Replaces: 04.95 Dual displacement motor 10VM Plug-in dual displacement motor 10VE for open and closed circuit applications Size 28-60 Series 5 Nominal pressure 280 bar Peak pressure 350 bar 10VM Contents

More information

RP series Rotor Pumps

RP series Rotor Pumps ontact etails RP series Rotor Pumps Nomenclature Features Low noise Substantial reduction of the operation noise, by to db (comparison with aikin products), and improved sound quality are achieved by adopting

More information

BAYARD is a company of. Hydraulic control valve Hydrobloc system

BAYARD is a company of. Hydraulic control valve Hydrobloc system BAYARD is a company of Hydraulic control valve Hydrobloc system Hydrobloc control valve 1 - Technical data Range: - DN 50 to 1000 for XGS design. - DN 50 to 800 for XG design. - DN 50 to 300 for XGA design

More information

stepper motor 2-phase hybrid stepper motor (bipolar) high protection class with plug or stranded wires optional with encoder / brake

stepper motor 2-phase hybrid stepper motor (bipolar) high protection class with plug or stranded wires optional with encoder / brake stepper motor 2-phase hybrid stepper motor (bipolar) high protection class with plug or stranded wires optional with / brake / 9 www.igus.de MOT-AN-S_EN_2070# part number (not configurable, only for illustration)

More information

AN ISOLATED SMALL WIND TURBINE EMULATOR

AN ISOLATED SMALL WIND TURBINE EMULATOR AN ISOLATED SMALL WIND TURBINE EMULATOR Md. Arifujjaman Graduate Student Seminar: Master of Engineering Faculty of Engineering and Applied Science Memorial University of Newfoundland St. John s, NL, Canada

More information

Evaporating Pressure Regulating Valve Type KVQ REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Evaporating Pressure Regulating Valve Type KVQ REFRIGERATION AND AIR CONDITIONING. Technical leaflet Evaporating Pressure Regulating Valve Type KVQ REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction...3 Features...3 Technical data...4 Ordering...4 Sizing...5 Valve selection...5

More information

Fixed Displacement Pump KFA for commercial vehicles in open circuits

Fixed Displacement Pump KFA for commercial vehicles in open circuits RE 91 501/05.98 Replaces: 11.96 Fixed Displacement Pump KFA for commercial vehicles in open circuits Sizes 23...107 Series 6 Nominal pressure 300 bar Peak pressure 350 bar KFA List of contents Features

More information

Variable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design

Variable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design Brueninghaus Hydromatik Series 1, for open circuits Axial piston - swashplate design, Back to back - design RE 93100/02.97 Sizes 60...260 Nominal Pressure up to 350 bar Peak Pressure up to 400 bar Preliminary

More information

Monitoring device NTS 30

Monitoring device NTS 30 P R O D U C T I N F O R M A T I O N Electronic level- and temperature monitoring device Monitoring device NTS 30 Contents Description Description... 2 Operating... 3 Design and electrical data... 4 Circuit

More information

APPLICATION. Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries

APPLICATION. Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries HYDRAULIC APPLICATION Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries Special vehicles Plastic and rubber machinery etc. CONTENTS Specification

More information

TeSys protection components

TeSys protection components Presentation, description -pole thermal overload relays TeSys D Presentation TeSys D thermal overload relays are designed to protect a.c. circuits and motors against: b overloads, b phase failure, b excessively

More information

Solenoid valve type EVR for Hydrocarbons

Solenoid valve type EVR for Hydrocarbons MAKING MODERN LIVING POSSIBLE Technical brochure Solenoid valve type EVR for Hydrocarbons EVR for Hydrocarbons is a direct or servo operated solenoid valve especially designed for liquid, suction, and

More information

OPERATION, INSTALLATION, & MAINTENANCE MANUAL. for. Aircon Flex-air AN Airlocks

OPERATION, INSTALLATION, & MAINTENANCE MANUAL. for. Aircon Flex-air AN Airlocks OPERATION, INSTALLATION, & MAINTENANCE MANUAL for Aircon Flex-air AN Airlocks Aircon Corporation P.O. Box 80446 2873 Chelsea Avenue Memphis, TN 38108-0446 Telephone: (901) 452-0230 FAX: (901) 452-0750

More information

Centriflow Plus High-pressure plug fan - Technical Data

Centriflow Plus High-pressure plug fan - Technical Data Centriflow Plus 3 High-pressure plug fan - Technical Data Contents General description...3 General survey chart...4 Design description Fan Impeller...5 Fan Inlet...5 base with base frame...5 Hub...5 Air

More information

VLT 2000 Series. How to size your VLT

VLT 2000 Series. How to size your VLT Selection of frequency converter Usually the size of frequency converter is chosen on the basis of the shaft output, as this may be the only value known. However, if the data are known for both the application,

More information

Electromechanical pressure switches

Electromechanical pressure switches Presentation Electromechanical pressure switches OsiSense XM For power circuits, type XMP Presentation Pressure switches type XMP are switches for power circuits (direct switching), with an adjustable

More information

HYBRID STEPPING MOTORS HY / HS / HN Series

HYBRID STEPPING MOTORS HY / HS / HN Series HYBRID STEPPING MOTORS HY / HS / HN Series Long Life Compact Design Bipolar / Unipolar Models Holding Torque up to High Performances Series HS and HN Several Options available (Encoders, Gearboxes,Cables,

More information

CJTX-C 15/15 0,75 (2V) F-400. Impeller size 2-speed fan. Installed power. (r/min) 230 V 400 V 690 V (kw) m3/h db(a) (kg)

CJTX-C 15/15 0,75 (2V) F-400. Impeller size 2-speed fan. Installed power. (r/min) 230 V 400 V 690 V (kw) m3/h db(a) (kg) CJTX-C 400 C/2h belt-driven double inlet extractor fan units. Order code 400 C/2h extractor fan units, with motor and transmission mounted inside the box, to operate outside the fire zone. Fan: Galvanised

More information

TECHNICAL INFORMATION

TECHNICAL INFORMATION TECHNICAL INFORMATION Model No. Description RP2300FC, RP2301FC Router CONCEPT AND MAIN APPLICATIONS Models RP2300FC and RP2301FC are upgraded sister tools of our current plunge-type electronic router Model

More information

Introduction INDEX. INTRODUCTION HSE

Introduction INDEX.  INTRODUCTION HSE Introduction INDEX SECTION PAGE INTRODUCTION ORDERING CODE GLOSSARY MOTOR OPTION TECHNICAL SE SE3 / SE5 SE7 / S7 SE9 / S9 SE12 / S12 SE14 / S14 SE14-2 / S14-2 SE17 / S17 SE17-2 / S17-2 SE21 / S21 SE21-2

More information

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure General-purpose Limit Switch CSM_DA-_N_DS_E The Limit Switch with Better Seal, Shock Resistance, and Strength A double seal on the head, a complete gasket cover, and other features ensure a better seal

More information

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

Type N-10, N-11 Hazardous Area Non-incendive Transmitters Electronic Pressure Catalog > Hazardous Area > N-10, N-11 Type N-10, N-11 Hazardous Area Non-incendive Transmitters Applications Natural gas compressors Wellhead monitoring Pipeline pressure General industrial

More information

Watts. xppower.com. Input. General. Environmental. Output. EMC & Safety. Output Voltages from 2.5 V to 48 V. Non-standard Outputs Available

Watts. xppower.com. Input. General. Environmental. Output. EMC & Safety. Output Voltages from 2.5 V to 48 V. Non-standard Outputs Available -0 Watts AEH Series s from. V to 8 V xppower.com Non-standard s Available Universal Input Single & Multiple Versions 0 C to +60 C Operating Temperature Efficiency up to 80% Non-standard Connectors Available

More information

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm 0102 Model Number Features 1.5 mm flush Accessories BF 8 Mounting flange, 8 mm Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 1.5 mm Installation flush

More information

DISC VALVE HYDRAULIC MOTORS

DISC VALVE HYDRAULIC MOTORS DISC VALVE HYDRAULIC CONTENTS Page Hydraulic otors Series S... 4 Hydraulic otors Series T... 25 Hydraulic otors Series V... 39 otor Special Features... 51 otors with Speed Sensor... 52 Application Calculation...

More information

XMPA12B2142 pressure sensor XMP - 12 bar - G 1/4 female - 2 NC - without control type

XMPA12B2142 pressure sensor XMP - 12 bar - G 1/4 female - 2 NC - without control type Characteristics pressure sensor XMP - 12 bar - G 1/4 female - 2 NC - without control type Main Range of product Pressure sensor type Pressure sensor name Pressure sensor size OsiSense XM Electromechanical

More information

DLE7.5CN V/50Hz 1~

DLE7.5CN V/50Hz 1~ dle75cn_102h4856_r290_2v_50hz_06-18_ds.xlsx Sales code: 102H4856 DLE7.5CN 2-240V/50Hz 1~ design Oil type Polyolester Refrigerant(s) R290 Oil viscosity 32cSt Displacement 7,48cm³ / 0,46cu.in Oil quantity

More information

Differential pressure switch MP 54, MP 55 and MP 55A

Differential pressure switch MP 54, MP 55 and MP 55A Data sheet Differential pressure switch MP 54, MP 55 and MP 55A MP 54 and MP 55 oil differential pressure switches are used as safety switches to protect refrigeration compressors against low lubricating

More information

PRESSURE SURGES IN PIPELINES

PRESSURE SURGES IN PIPELINES CHAPTER 4 PRESSURE SURGES IN PIPELINES 4.1 FEATURES OF PRESSURE SURGE In the past, water engineers were facing problems with repeated pipe bursts, failing seals etc. They termed the cause of failure as

More information

Technical Data. Dimensions

Technical Data. Dimensions 00 Model Number Features mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,

More information

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications. Rated operating distance s n 5 mm 0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching

More information

TECHNICAL DESCRIPTION

TECHNICAL DESCRIPTION TECHNICAL DESCRIPTION Exhaust Hose Reel ser. 865, electric motor driven No. 981118101 Description Limit switches, for hose coiling and uncoiling integrated in drive unit. Motor turns drum via a planetary

More information

Hazardous Duty Explosion Proof, Three Phase, Blue Chip Severe Duty

Hazardous Duty Explosion Proof, Three Phase, Blue Chip Severe Duty Applications: Hazardous Duty Explosion Proof, Three Phase Class I Groups C & D, Class II Groups F & G, Rigid Base installed in hazardous environments as defined by the motor's explosion proof class and

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 00 Model Number Features 5 mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,

More information

Technical Data. Dimensions

Technical Data. Dimensions 00 Model Number Features Comfort series 30 mm non-flush Accessories MHW 0 Modular mounting bracket V-G Female connector, M, 4-pin, field attachable V-W-N-M-PUR Female cordset, M, -pin, NAMUR, PUR cable

More information

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS Government Approved Test Laboratory (Previously AIA) Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS ZEST

More information

Fixed Displacement Motor A4FM

Fixed Displacement Motor A4FM Fixed Displacement Motor 4FM RE 91 12/4. replaces: 3.95 and RE 91 1 for open and closed circuits Sizes 22...5 Series 1, Series 3 Nominal pressure up to bar Peak pressure up to 45 bar Index Features 1 Ordering

More information

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm 0102 Model Number Features 2 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-12 Quick mounting bracket with dead stop BF 12 Mounting flange, 12 mm Technical Data specifications Switching

More information

Engineering Data RPM: 3000 HP: Serv. Factor: 1,0 KW:,37 Form Factor: 1,00 Amps: 20 KW2: Form Factor 2: FLA2: Volts: 24. Frame: 71D

Engineering Data RPM: 3000 HP: Serv. Factor: 1,0 KW:,37 Form Factor: 1,00 Amps: 20 KW2: Form Factor 2: FLA2: Volts: 24. Frame: 71D Product Features Catalog No: L085/O043/098066.00 Model: CI42D34FT7C Engineering Data RPM: 3000 HP: Serv. Factor: 1,0 KW:,37 Form Factor: 1,00 Amps: 20 KW2: Form Factor 2: FLA2: Volts: 24 Frame: 71D Max

More information

Inductive slot sensor

Inductive slot sensor 0102 Model Number Features 3.5 mm slot width Usable up to SIL 3 acc. to IEC 61508 Nonferrous targets Application Danger! In safety-related applications the sensor must be operated with a qualified fail

More information

Differential pressure controls/ Lube oil protection controls MP 54 and MP 55 REFRIGERATION AND AIR CONDITIONING. Technical leafl et

Differential pressure controls/ Lube oil protection controls MP 54 and MP 55 REFRIGERATION AND AIR CONDITIONING. Technical leafl et Differential pressure controls/ Lube oil protection controls MP 54 and MP 55 REFRIGERATION AND AIR CONDITIONING Technical leafl et Contents Page Introduction... 3 Features... 3 Approvals... 3 Materials

More information

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH THIS MANUAL IS INTENDED FOR TECHNICAL STAFF IN CHARGE OF THE INSTALLATION, THE OPERATION AND THE MAINTENANCE OF THIS PRODUCT CAUTION!

More information

Series BLK Oil - air cooler

Series BLK Oil - air cooler Series BLK Oil - air cooler maintenance friendly design broad performance range compact dimensions rugged cooling matrix low noise emissions comprehensive accessories DE 35 0001 04/2004 Bühler Meß- und

More information

3000 Series OPTIMASS Mass Flowmeter. Stainless Steel Hastelloy

3000 Series OPTIMASS Mass Flowmeter. Stainless Steel Hastelloy KROHNE 07/2005 7.02446.25.00 GR 3000 Series OPTIMASS Mass Flowmeter with single Z-shaped measuring tube Stainless Steel Hastelloy Status: 10/99 One tube no limits No limits with tube material No limits

More information

Electromechanical pressure switches

Electromechanical pressure switches References : pages / and / page /5 Presentation Functions Pressure switches type XMX and XMA are switches for control circuits, with an adjustable differential. They are used to control the pressure of

More information

PVQ 13 A2 R SE 1 S 20 C-11 D

PVQ 13 A2 R SE 1 S 20 C-11 D PVQ - Variable Displacement Piston Pump PVQ 13 A2 R SE 1 S 2 C-11 D 1 2 3 4 6 7 8 9 1 1 Model Series PVQ Inline Piston Pump Variable Volume Quiet Series 4 Rotation Viewed from shaft end R Right hand, standard

More information

Integral type Differential pressure flowmeter VNT Series

Integral type Differential pressure flowmeter VNT Series Integral type Differential pressure flowmeter VNT Series OUTLINE VH series Wafer-Cone differential pressure flowmeter and high precision differential pressure transmitter are integrated into one flowmeter.

More information

REULAND DIRECT ACTING MAGNETIC DISC BRAKE ONLY ONE MOVING PART SIMPLE / DIRECT ACTING / TROUBLE FREE OPERATION

REULAND DIRECT ACTING MAGNETIC DISC BRAKE ONLY ONE MOVING PART SIMPLE / DIRECT ACTING / TROUBLE FREE OPERATION REULAND DIRECT ACTING MAGNETIC DISC BRAKE ONLY ONE MOVING PART SIMPLE / DIRECT ACTING / TROUBLE FREE OPERATION THE WORLD S SECOND SIMPLEST BRAKE DESIGN Concept / Design / Reality SEVEN MAJOR PARTS, ONLY

More information

Differential pressure controls, Type MP 54, 55 and 55A

Differential pressure controls, Type MP 54, 55 and 55A MAKING MODERN LIVING POSSIBLE Technical brochure Differential pressure controls, Type MP 54, 55 and 55A MP 54 and oil pressure controls are used as safety switches to protect refrigeration compressors

More information

GM-7000 Series CE Approved Gas Control Valve

GM-7000 Series CE Approved Gas Control Valve Product Bulletin Issue Date November 16, 2012 GM-7000 Series CE Approved Gas Control Valve The GM-7000 Series multi-function gas control valve works in conjunction with an electronic sequence control unit

More information

HYDRAULIC MOTORS MTM APPLICATION OPTIONS CONTENTS EXCELLENCE GENERAL

HYDRAULIC MOTORS MTM APPLICATION OPTIONS CONTENTS EXCELLENCE GENERAL HYDRAULIC OORS APPLICAION» Skid Steer Loaders» etal working machines» renchers» Augers» Agricultural machines» Road building machines» Special vehicles» ine machines» Woodworking and sawmill machinery»

More information

2MW baseline wind turbine: model development and verification (WP1) The University of Tokyo & Hitachi, Ltd.

2MW baseline wind turbine: model development and verification (WP1) The University of Tokyo & Hitachi, Ltd. 2MW baseline wind turbine: model development and verification (WP1) The University of Tokyo & Hitachi, Ltd. Downwind turbine technology, IEA Wind Task 40 First Progress Meeting, Tokyo, Japan 11 Dec, 2017

More information

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-00-VEF 7.03 Max. operating pressure 30 mbar Compact design High flow values Low weight Low power consumption

More information

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800 KROHNE 1/22 7.236.22. GR Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 8 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters

More information

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm Dimensions 65 GW2 40 35 9 5 GW1 14 11 9 5.4 M20 x 1.5 0102 Model Number S M12 x 1.5 Features 77.5 LED V Direct mounting on standard actuators Compact and stable housing with terminal compartment connection

More information

Position switches FP series

Position switches FP series A Position switches FP series Selection diagram 0 08 8 9 0 0 0 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fiber glass rod gasket sphere sphere adjustable lever safety adjustable lever

More information

Differential Pressure Control Types MP 54, MP 55 and MP 55A

Differential Pressure Control Types MP 54, MP 55 and MP 55A MAKING MODERN LIVING POSSIBLE Data sheet Differential Pressure Control Types MP 54, MP 55 and MP 55A MP 54 and MP 55 oil differential pressure controls are used as safety switches to protect refrigeration

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 15 mm non-flush Stainless steel housing Accessories BF 30 Mounting flange, 30 mm Technical Data specifications Switching element function NAMUR, NC Rated operating

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications

More information

DEEP WELL SUBMERSIBLE PUMPS. An ISO 9001 & Company

DEEP WELL SUBMERSIBLE PUMPS. An ISO 9001 & Company C.R.I. PUMPS DEEP WELL SUBMERSIBLE PUMPS EVERGREEN SERIES - 5Hz An ISO 91 & 141 Company Submersible Pumps C.R.I. Submersible Pumps are the products of the expertise gained from over four decades of experience,

More information

Electric expansion valves Types AKV 10, AKV 15 and AKV 20

Electric expansion valves Types AKV 10, AKV 15 and AKV 20 Data sheet Electric expansion valves Types AKV 10, AKV 15 and AKV 20 AKV are electrically operated expansion valves designed for refrigerating plants. The AKV valves are normally controlled by a controller

More information

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119 Pressure switch type CS December 2001 DKACT.PD.P10.A2.02 520B1119 Introduction Pressure switch type CS is part of the Danfoss pressure control range. All CS pressure switches have a built-in pressure-operated,

More information

NLE10CN V/50Hz 1~

NLE10CN V/50Hz 1~ nle10cn_105h6175_r290_2v_50hz_06-18_ds.xlsx Sales code: 105H6175 NLE10CN 2-240V/50Hz 1~ design Oil type Polyolester Refrigerant(s) R290 Oil viscosity 32cSt Displacement 10,09cm³ / 0,62cu.in Oil quantity

More information

HYDRAULIC MOTORS MV APPLICATION GENERAL

HYDRAULIC MOTORS MV APPLICATION GENERAL HYDRAULIC V APPLICAION» Conveyors» etal working machines» Agriculture machines» Road building machines» ining machinery» Food industries» Special vehicles» Plastic and rubber machinery etc. CONENS Specification

More information

Prewired position switches FA series

Prewired position switches FA series 2 Prewired position switches FA series Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 51 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable lever 41 45

More information

enclosed product catalogue 2010 isolating switches main/emergency off switches changeover switches insulated stainless steel mild steel

enclosed product catalogue 2010 isolating switches main/emergency off switches changeover switches insulated stainless steel mild steel enclosed product catalogue 2010 isolating switches main/emergency off switches changeover switches insulated stainless steel mild steel kraus & Naimer enclosed switch catalogue Contents This catalogue

More information

Prewired position switches FA series

Prewired position switches FA series Prewired position switches Technical data Housing Made of metal, coated with baked epoxy powder 2 m wired cable with 5x0,5 mm 2 wires marked SEV and IMQ Protection degree: IP6 General data Ambient temperature:

More information

Automatic Valve Proving Control

Automatic Valve Proving Control ISO 9001 Automatic Valve Proving Control 7 696 LDU11 UL recognized FM approved Features Performs leak test of the gas shut-off valves before start-up and/or immediately after burner shut-down No inlet

More information

WhirlWind Multifunctional gas control Fully integrated gas-air system with control and safety function GB-WND 055 D01

WhirlWind Multifunctional gas control Fully integrated gas-air system with control and safety function GB-WND 055 D01 WhirlWind Multifunctional gas control Fully integrated gas-air system with control and safety function Printed in Germany Edition 01 1 6 Technical Description Integrated gas-air system with high power

More information

Protection of motor circuits

Protection of motor circuits Protection of motor circuits Circuit breaker/contactor coordination A circuit supplying a motor may include one, two, three or four switchgear or When a number of devices are used, they must be coordinated

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 10770-3 First edition 2007-10-15 Hydraulic fluid power Electrically modulated hydraulic control valves Part 3: Test methods for pressure control valves Transmissions hydrauliques

More information

MTB Load Cell. Globally Approved for Accuracy and Safety. MTB Load Cell Fully Approved

MTB Load Cell. Globally Approved for Accuracy and Safety. MTB Load Cell Fully Approved MTB Load Cell Process Weighing Due to the hermetically sealed design, MTB is ideal for harsh environments in process or food applications. The full set of approvals makes it the right choice for your application.

More information

Fixed Displacement Plug-In Motor A2FE

Fixed Displacement Plug-In Motor A2FE www.phphyds.com Series 6, axial tapered piston, bent axis design for mounting in mechanical gearboxes Sizes 28...355 Nom. Pressure up to 400 bar Peak Pressure up to 450 bar he fixed displacement plug-in

More information

Page - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 ITEM QUANTITY FOR MODEL 302

Page - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 ITEM QUANTITY FOR MODEL 302 CONTENTS. Page - SPECIFICATIONS 200 SPECIFICATION 200 SELECTION CHART PFC 201 SELECTION CHART 202 TYPE KEY AND CURVE SPECIFICATIONS 203 PERFORMANCE CURVE 2 204 PERFORMANCE CURVE 3 205 PERFORMANCE CURVE

More information

Calibration Summary of Test Report No.: Sample

Calibration Summary of Test Report No.: Sample Calibration Summary of Test Report No.:30043 Rion Type: NL52/EX Serial no: 00732122 Customer: Scantek, Inc. Address: 6430 Dobbin Rd., Suite C, Columbia MD, 21045 Contact Person: Mariana Buzduga Phone No.:

More information

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners BULLETIN MT2035-07/05 Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners M/MR Series M411, M511, M611 M420, M520, M620, MR410, MR510, MR610 MR212D, MR212E, MR212G and MR212J (Flanged),

More information

Level transmitter LT 100

Level transmitter LT 100 KROHNE 09/2001 7.02363.21.00 GR/PRINTO Level transmitter LT 100 Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters

More information

Socket P2RF-05-S P2RF-08-S Clip & Release Lever Nameplate R99-11

Socket P2RF-05-S P2RF-08-S Clip & Release Lever Nameplate R99-11 Screwless Clamp Terminal Socket P2RF@@S Screwless clamping greatly contributes to reducing wiring time. No over or under tightening of cable connection so better contact reliability is achieved. Double

More information

Meta-MEC Manual Motor Starters

Meta-MEC Manual Motor Starters www.lsis.biz Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 45 mm 70 mm 63AF 100AF 3 LS Meta-MEC Manual Motor Starters deliver more

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable

More information

On-Off switch. Selectable manual control for commissioning. Remote start input for control via an irrigation controller, or external sensor.

On-Off switch. Selectable manual control for commissioning. Remote start input for control via an irrigation controller, or external sensor. SPEEDMAN VARIABLE SPEED PUMP SET VARIABLE SPEED PUMP SET PRODUCT DESCRIPTION Variable speed / constant pressure system consisting of a Davey VM vertical multistage pump with Speedman controller, VSD unit,

More information

ATH 500 M. Pumping speed ATH 500 M. 3.1 Vacuum generation / Turbopumps / Magnetically levitated / ATH 500 M. Page 398 / Part 3.1

ATH 500 M. Pumping speed ATH 500 M. 3.1 Vacuum generation / Turbopumps / Magnetically levitated / ATH 500 M. Page 398 / Part 3.1 ATH 500 M Compact integrated drive Installation in any orientation Water or air cooled CE marked and ROHS compliant Heated version (MT) available for corrosive applicaitons. Pumping speed N 2 He H 2 Ar

More information

Wing Union/Hammer Union Pressure Sensors. Datasheet. Models 435/437

Wing Union/Hammer Union Pressure Sensors. Datasheet. Models 435/437 Wing Union/Hammer Union Pressure Sensors Models 435/437 0 psi to 5000 psi; 0 psi to 6000 psi; 0 psi to 10000 psi; 0 psi to 15000 psi; 0 psi to 20000 psi; 0 bar to 350 bar; 0 bar to 400 bar; 0 bar to 700

More information

Technical Data. General specifications. Rated operating distance s n 2 mm

Technical Data. General specifications. Rated operating distance s n 2 mm 0102 Model Number Features 2 mm flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Rated operating distance s n 2 mm Installation

More information

PRODUCT CONFIGURATOR AT mcr Monsun. smoke extraction and air supply axial-flow fans

PRODUCT CONFIGURATOR AT   mcr Monsun. smoke extraction and air supply axial-flow fans PRODUCT CONFIGURATOR AT WWW.MERCOR.COM.P mcr Monsun smoke extraction and air supply axial-flow fans APPICATION mcr Monsun fans are designed to extract hot air, smoke and exhaust gases from fire-exposed

More information

References 6 k thermal overload relays, adjustable from 0.11 to 16 A

References 6 k thermal overload relays, adjustable from 0.11 to 16 A s 6 k thermal overload relays, adjustable from 0.11 to 16 A 3-pole relays with screw clamp terminals These overload relays are designed for the protection of motors. They are compensated and phase failure

More information

Dual Solenoid Gas Valve Installation

Dual Solenoid Gas Valve Installation Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing or servicing FLYNN Gas Products. Carefully follow all instructions in this bulletin and all instructions

More information

INSTALLATION AND MAINTENANCE MANUAL

INSTALLATION AND MAINTENANCE MANUAL INSTALL.06 INSTALLATION AND MAINTENANCE MANUAL WORLDWIDE ELECTRIC THREE-PHASE MOTORS WorldWide Electric Corporation Phone: 1-800-808-2131 Ext. 3 Fax: 1-800-711-1616fffffgff Website: www.worldwideelectric.net

More information

Differential pressure switch / Lube oil protection control MP 54 and MP 55

Differential pressure switch / Lube oil protection control MP 54 and MP 55 Data sheet Differential pressure switch / Lube oil protection control MP 54 and MP 55 MP 54 and MP 55 oil differential pressure switches are used as safety switches to protect refrigeration compressors

More information

SIHI LPH-X - Liquid Ring Compressors

SIHI LPH-X - Liquid Ring Compressors - Liquid Ring Compressors LPH 50523 LPH 60527 Pressure range: Suction volume range: 0.2 to 1.5 bar 260 to 780 m³/h CONSTRUCTION Sterling SIHI liquid ring compressors are displacement compressors with a

More information

Liquid ring vacuum pumps in compact design

Liquid ring vacuum pumps in compact design Liquid ring vacuum pumps in compact design LEM 25, LEM 5 Pressure range: Suction volume flow: 33 to 113 mbar 4 to 6 m³/h CONSTRUCTION SIHI liquid ring vacuum pumps are displacement pumps of uncomplicated

More information

TURQUOISE SWITCHES ABJ (BJ) SWITCHES

TURQUOISE SWITCHES ABJ (BJ) SWITCHES Ultra-miniature Size Sealed Switches TURQUOISE SWITCHES ABJ (BJ) SWITCHES Terminal type Mounting hole 2.3 mm type FEATURES Ultra-miniature size, High sealing performance sealed switches Elastomer double

More information

Liquid ring compressor

Liquid ring compressor Liquid ring compressor KLH 47005, KLH 47105 Compression pressures: Suction volume flow: 2 to 11 bar 56 to 65 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring compressors are displacement compressors of

More information

Technical Manual. Liquid Level Transmitter CT801-LB/S

Technical Manual. Liquid Level Transmitter CT801-LB/S CT801-LB/S Technical Manual SAS au Capital de 2 158 244-444 871 933 R.C.S. Bourges - APE : 2651B Headquarter : 9, rue Isaac Newton - 18000 Bourges - France Technical Manual CT801-LB/S 1 st Edition Released

More information

Relative pressure transmitter type 520

Relative pressure transmitter type 520 Relative pressure transmitter type 520 Pressure range -1... 9 bar / 0... 2.5 1000 bar The compact type 520 pressure transmitter is based upon the Huba Control developed thick film technology where the

More information

STAINLESS STEEL GRAND SERIES

STAINLESS STEEL GRAND SERIES STAINLE STEEL GRAND SERIES STAINLE STEEL GRAND SERIES DEEPWELL SUBMERSIBLE PUMPS STAINLE STEEL - GRAND SERIES C.R.I. Always equips itself in advance to face the exponentially growing technological challenges

More information