MANUAL FLOW CONTROL 2-1/2" - 18" QUICKSET FLOW CHART
|
|
- Morgan Stella Sanders
- 6 years ago
- Views:
Transcription
1 This chart performs two functions: It allows you to calculate the permanent pressure drop for any size Quickset or. This figure is useful mostly in the design process, for system calculations. It allows you to find the signal in inches at any given GPM within the recommended flow range. The chart gives pressure drops for, Quickset, and Quickset. is given for each piping configuration: is an installation where there is adequate straight-run piping before and after the valve. is for valves installed immediately after an elbow bend in piping. Piped at Control is for valves installed immediately after a control valve. The Pressure Drop values shown reflect the idea that it is desirable to have permanent pressure drop of less than 1 lb, requiring less pump. Example of chart usage: Obtain the and for a 3" Quickset at 68 GPM piped next to an elbow. 2-1/2" 3" Permanent Pressure Permanent Drop Pressure Drop 4" GPM
2 2-1/2" GPM
3 3" GPM
4 4" GPM
5 5" GPM
6 6" GPM
7 8" GPM
8 10" GPM
9 12" GPM
10 14" Metering Station Metering Station Piped at Control GPM
11 16" Metering Station Metering Station Piped at Elbow Piped at Control GPM
12 18" GPM
Balancing HVAC Hydronic Systems Part 3: Flow Measurement Valves
Balancing HVAC Hydronic Systems Part 3: Flow Measurement Valves Monday Morning Minutes by Norm Hall, August 20, 2018 The flow balance of a hydronic system is a critical component in the commissioning of
More informationResidential Pressure Booster Systems
Residential Pressure Booster Systems HOW IT WORKS When the pressure available is insuffi cient it is necessary to install a boosting system. FLUX BOOSTING SYSTEM starts and stops according to the user
More informationSFC. SKYLINE FLOW CONTROLS INC. The Leader of Accurate and Reliable Flow Measurement DESCRIPTION & APPLICATIONS: ADVANTAGES:
SKYLINE FLOW CONTROLS INC. SFC Skyline Flow Controls Wedge Meter (SFC-WM) The SFC wedge meter is a differential pressure device for use on all fluids. It is especially designed for slurries and liquids
More informationUnderstanding and Compliance of the Virginia Graeme Baker Pool & Spa Safety Act
Understanding and Compliance of the Virginia Graeme Baker Pool & Spa Safety Act Sponsored by the U.S. Consumer Product Safety Commission Presented By: Rick English, Certified Building Professional, CPOI
More informationFull Range Pressure Compensating Variable Flow Control
Engineering & Manufacturing Solutions Specifications: See flow chart for capacity. Rated for 3000 psi (207 bar). Weighs 7- ¾ lbs. (3.52 kg). 30-Micron Filtration Recommended. Torque to turn side lever
More informationLAKOS Waterworks. PWC Series Sand Separators. Installation & Operation Manual LS-829 (10/12)
LAKOS Waterworks PWC Series Sand Separators Installation & Operation Manual LS-829 (10/12) Table of Contents Separator Operation... 3 Individual Model Details.... 4 Flow vs. Pressure Loss Chart 4 Installation
More informationPumping Systems for Landscaping Pumps, Controls and Accessories. Mark Snyder, PE
October 21, 2010 Pumping Systems for Landscaping Pumps, Controls and Accessories Mark Snyder, PE Pump Station Design Purpose of Pump Stations Pump stations are designed to boost water pressure from a lower
More informationPRESSURE DROP CHARTS
PRESSURE DROP FOR SMALL PEX TUBING AT 100 F Take the total heat load (BTUH) for the area that the loop is covering and divide it by 501. Divide the result with the Delta-T to find GPM for the loop. Find
More informationLPP S STEMS WORKSHEET
LPP S STEMS WORKSHEET ABSORPTION AREA STEP I Calculate daily waste flow. BDR House = Gallon per day (GPD) STEP 2. Determine loading rate (First page of soil profile) Loading Rate = GPD/Sq. Ft. STEP 3.
More informationPumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out
PumpAgents.com - Click here for Pricing/Ordering Model 31670-Series Dual Max 7.5 GPM (28 LPM) AUTOMATIC TWO STAGE WATER SYSTEM WITH ACCUMULATOR TANK AND PUMPGARD STRAINER IDEAL FOR PLEASURE AND COMMERCIAL
More informationLINE PROPORTIONERS LP NPR260 Approvals: UL, ULC
Approvals: UL, ULC Simple Inexpensive & Accurate Foam Proportioning Inlet Pressure Choices 90-200 PSI Flow Rate 44-578 GPM Special Designs Available Flow & Pressure Salt Water Compatible Description National
More informationSEMI FIXED/PORTABLE LINE PROPORTIONERS SLP NPR270
SEMI FIXED/PORTABLE LINE PROPORTIONERS SLP Simple Inexpensive Foam Proportioner Portable Inlet Pressure Choices 90 to 200 PSI Foam Rate 44 GPM to 362 GPM Salt Water Compatible Special Flow And Pressure
More informationLV LOADER DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE
LV LOADER DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE SPECIFICATIONS: 10 gpm (38 lpm) Nominal Capacity. Rated up to 4000 psi (275 bar). Port Sizes-Inlet/Outlet #8SAE (3/4-16). Work Ports #8SAE
More information586, ,057 78, N/A $ 781,657 $ 586,243 $ - $ 40 N/A $ 16,307,537 $ 3,261,507 $ - $ 3,261,507
(New) New 50000 Dams Gainer Dam 1927 $ 3,430,846 100 N/A $ 108,374,370 $ 37,931,030 $ - $ 37,931,030 50001 Dams Regulating Dam - Horseshoe Structure 1918 $ 50,591 100 N/A $ 1,811,160 $ 362,232 $ - $ 362,232
More informationDW Module 8: Distribution Answer Key
DW Module 8: Distribution Answer Key Unit 1: Unit 1 Exercise 1. To become certified in distribution systems, a person must: a. Successfully complete the Water Class E Distribution System certification
More informationA050-1/2 INCH AIR OPERATED double DIAPHRAGM PUMP
A050 - /2 INCH AIR OPERATED double DIAPHRAGM PUMP A050 /2 Pump /2 Aluminum NPT or BSP Connections Zinc Plated Hardware Non-Metallic Muffler Suction Right / Discharge Right Standard Porting SPECIFICATIONS
More informationFlow Material Length. Weight GPM LPM. Style 3095
Akron Municipal Eductors feature a large, easy to read, and removable metering dial with infinite settings between 0% and 6%. Detents at 1 4, 1 2, 1, 3 and 6%. The Eductors are rated to flow at 200 psi
More informationAirCannonPlans.Com. High Powered Water Cannon
High Powered Water Cannon My friend and I had water wars with our neighbors back in middle school. Standard water balloons just weren't doing the job. We knew we needed something with more power. I originally
More informationTANK MATE INCLUDES: TOOLS REQUIRED: CONRADER VALVES 3/4 WRENCH **TUBING CUTTERS TEE PETCOCK TEE ASSEMBLY 8 FOOT NYLON TUBING
CONRADER VALVES TANK MATE AUTOMATIC DRAIN VALVE INSTALLATION KIT INCLUDES: TEE PETCOCK TEE ASSEMBLY 8 FOOT NYLON TUBING WV-1 DRAIN VALVE TOOLS REQUIRED: 3/4 WRENCH **TUBING CUTTERS ** NEEDED TO CUT METAL
More informationSanitizers. Sanitizers. Sanitizers for Pools & Spas
for Pools & Spas 207 IntelliChlor Salt Chlorinator Featured Highlights IntelliChlor Salt Chlorinator IntelliChlor Salt Chlorinator uses common table salt to produce all the chlorine a pool needs, safely,
More informationPro-V Multivariable Flowmeter
Pro-V Multivariable Flowmeter Model M23 Insertion Meter M23-V flowmeter provides cost-effective volumetric flow monitoring solution for most liquids M23-VT incorporates temperature sensing to provide a
More informationVERTICAL BLADDER TANK
Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Tight Spaces UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure
More informationInstallation, Operation, and Maintenance Manual
Installation, Operation, and Maintenance Manual ehtx Series High Efficiency Separators 1365 North Clovis Avenue Fresno, California 93727 2282 (559) 255 1601 info@lakos.com www.lakos.com LS-926A (2/13)
More informationPX4 P L A S T I C PX4 PERFORMANCE WIL T-02
PX4 P L A S T I C PX4 PERFORMANCE WIL-10161-T-02 Section 5B Pro-Flo X TM Operating Principal The Pro-Flo X air distribution system with the revolutionary Efficiency Management System (EMS) offers flexibility
More informationHORIZONTAL BLADDER TANK
Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Low Ceilings UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure
More informationSanitizers. Sanitizers. Sanitizers for Pools & Spas
Sanitizers Sanitizers for Pools & Spas 213 213 IntelliChlor Salt Chlorinator Featured Highlights IntelliChlor Salt Chlorinator IntelliChlor Salt Chlorinator uses common table salt to produce all the chlorine
More informationV248 Series 3-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants
V248 Series 3-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants Product Code No. LIT-12011515 Issued June 19, 2009 The V248 Series 3-Way Pressure-Actuated Water-Regulating Valves
More informationPumping Apparatus Driver/Operator Apparatus Testing. Chapter Test. Directions: Write the correct letter on the blank before each question.
Chapter 15 Test Name: Date: Directions: Write the correct letter on the blank before each question. Objective 1: Distinguish among preperformance tests for pumping apparatus. 1. Which standard is commonly
More informationPump Stages. By Tom Murray
Pump Stages By Tom Murray As is often the case, we in the fire service tend to make things more difficult than they need to be. I believe this is the situation when discussing the pros and cons of single,
More informationProper Pump Installation Practices
Proper Pump Installation Practices 80-779, Rev. 10/08 There is a Reason Every Unit Comes With This Bright Orange Tag! Proper Alignment and Coupling Installation Do Not Drive Coupling Onto Shaft Pump Alignment
More informationGrangeville Country Club Golf Course
1 Grangeville Country Club Golf Course Water Storage Well 2 OBJECTIVES Develop a new irrigation system design for the Grangeville Country Club Golf Course (Holes 2-9) Produce a set of working blueprints
More informationSINGLE VALVE WITH LOW-FLOW BYPASS
CONTROL VALVES Pressure Reducing Valve Sizing Guide Sizing pilot operated reducing valves is not a complicated process. It starts with determining requirements and following these guidelines in valve size
More informationPX800 M E T A L PX800 PERFORMANCE WIL T-08
PX800 M E T A L PX800 PERFORMANCE WIL-11220-T-08 Section 5B Pro-Flo X TM Operating Principal The Pro-Flo X air distribution system with the revolutionary Efficiency Management System (EMS) offers flexibility
More informationME 333 Fluid Mechanics. Lab Session VISCOUS LOSSES IN PIPES
ME 333 Fluid Mechanics Lab Session VISCOUS LOSSES IN PIPES Introduction Flow in pipes, laminar or turbulent, is subject to pressure losses that result from the viscous stresses on the wall of the pipe.
More informationTechnical Bulletin. Parts and Service News. LPG Lock-Off valve replacement procedures for 4.2 Liter Ford V6
Equipment Affected Technical Bulletin LPG Lock-Off valve replacement procedures for 4.2 Liter Ford V6 Ford 4.2L V-6 powered tractors with LPG fuel systems. Part Description Discrepancy Fuel Pressure Lock-off
More informationSELECTION & APPLICATION
G O R M A N - R U P P P U M P S SELECTION & APPLICATION OF SELF-PRIMING CENTRIFUGAL PUMPS GRpumps.com G O R M A N - R U P P P U M P S PUMP SELECTION To assist with the selection of self-priming pumps,
More informationappendix a recommended rules For sizing the water supply system PRE-PRINT Chart a 1.2 FriCtion losses For Disk-type water Meters
recommended rules For sizing the water supply system Because of the variable conditions encountered, it is impractical to lay down definite detailed rules of procedure for determining the sizes of water
More informationOBSOLETE DESIGN DATA. CONCENTRATE CONTROLLERS 2, 3", 4", 6" and 8" (50, 80, 100, 150, and 200 mm)
March 1, 2001 Foam 210 a 1. PRO DUCT NAME Viking Concentrate Controller 2,, (102 mm) (152 mm), (203 mm) Available since 1996. 2. MANUFACTURED FOR THE VIKING COR PO RA TION 210 North Industrial Park Road
More informationWater Management Plan For The Blue Ocean Golf Club
Water Management Plan For The Blue Ocean Golf Club A water management plan reviews current water management practices and identifies opportunities for improvement in water use efficiency/conservation for
More informationRESIDENTIAL WATER DISTRIBUTION
RESIDENTIAL WATER DISTRIBUTION This case study demonstrates the steady-state simulation of the fresh water (drinking water) reticulation system in a small village. WATER RETICULATION Page1 WATER RETICULATION
More informationAPPENDIX A RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEM CHART A 1.2 FRICTION LOSSES FOR DISK-TYPE WATER METERS 1-1/2"
RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEM Because of the variable conditions encountered, it is impractical to lay down definite detailed rules of procedure for determining the sizes of water
More informationAPPENDIX A RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEMS CHART A-1 FRICTION LOSSES FOR DISK-TYPE WATER METERS 1-1/2"
RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEMS Because of the variable conditions encountered, it is impractical to lay down definite detailed rules of procedure for determining the sizes of water
More informationTROUBLESHOOTING GUIDELINES
TROUBLESHOOTING GUIDELINES PROBLEM: Performance 1. The most common problem in this area comes from inadequate flow to the LAKOS Separator(s). All LAKOS Separators operate within a prescribed flow range
More informationAccu-Tab Systems 1000 Series by Axiall Corporation
Accu-Tab Systems 1000 Series by Axiall Corporation Installation and Operating Instructions Model 1050 DANGER: DO NOT MIX CHEMICALS! The Accu-Tab chlorinator is designed for use with Axiall approved tablets
More informationTanker Fill Tests. Evaluating Direct Fill Lines DeKalb County, Alabama. November 16, Tests DeKalb County, AL
www.gotbigwater.com Tanker Fill Tests Evaluating Direct Fill Lines DeKalb County, Alabama November 16, 2008 Overview On November 15 th and 16 th, 2008, the DeKalb County (AL) Association of Fire Departments
More informationNo E. General Information. Averaging Pitot Tube Flow Sensor HITROL CO., LTD.
No. 2000-03E Averaging Pitot Tube Flow Sensor HITROL CO., LTD. M e a s u r e m e n t Pr i n c i p l e Measurement principle of Hitbar sensor is explained below. When a Hitbar is installed in the pipeline
More informationTurboDraft Fire Eductor
TurboDraft Fire Eductor Operating Manual Introduction The TurboDraft is designed to be used for rural water supply operations. Many of us take for granted that there is a fire hydrant on every corner.
More informationA centrifugal pump consists of an impeller attached to and rotating with the shaft and a casing that encloses the impeller.
Centrifugal pump How centrifugal pumps work A centrifugal pump consists of an impeller attached to and rotating with the shaft and a casing that encloses the impeller. In centrifugal pump, liquid is forced
More informationHill PHOENIX Second Nature Medium Temperature Secondary Refrigeration Start-Up Guide
Hill PHOENIX Second Nature Medium Temperature Secondary Refrigeration Start-Up Guide Secondary Coolant System Start-Up Procedures June 2006 Produced by the Hill PHOENIX Learning Center DISCLAIMER This
More informationRCD - Ultra-Rugged Differential Pressure Flowmeter
0.15-1 to 85-600 GPM Liquids 2.5-25 to 300-1700 SCFM Gases 1/2 to 3 Line Sizes Bronze or 316-Ti Stainless Steel Mechanical Indicator, Digital Indicator, Transmitters and Switches Available Custom Calibrations
More informationModel 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual
10-12 Steel Pipe Squeezer Sch. 40 & Sch. 80 Operations Manual 1.0 Introduction This manual is issued as a basic operation manual covering the Regent Model 7989T, Pipe Squeezer and Pump as manufactured
More informationV248 Series 3-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants
Code No. LIT-19576 Issued June 22, 21 V248 Series -Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants Description The V248 Series -Way Pressure-Actuated Water-Regulating Valves
More informationRESIDENTIAL IRRIGATION WORKSHOP IRRIGATION 101 AND BEYOND FOR WEST BENCH RESIDENTS
RESIDENTIAL IRRIGATION WORKSHOP IRRIGATION 101 AND BEYOND FOR WEST BENCH RESIDENTS UNDERSTANDING BASIC HYDRAULICS Hydraulics is defined as the study of fluid behavior, at rest and in motion. Also known
More informationPRESSURE ADJUSTMENT Main pressure adjustment
8001-38 PRESSURE ADJUSTMENT Main pressure adjustment Adjustment preparation work Pressure is adjusted with control valves. The following preparations are required for adjusting with control valves. 1.
More informationLiquid Level Controllers
Liquid Level Controllers ALL PUMPS LLC-2Y For both pump up and down control. Variable On/Off set points. NDP-15/20/25/32, DP-10/15 & *NDP-40/50/80 LLC-1 Pump up and down versions available. 6 to 12 differential
More informationDOMESTIC HOT WATER TEMPERATURE CONTROL with SAFEGUARD
ETV Platinum Plus R C O R P O R A T I O N Electronic Tempering Valve DOMESTIC HOT WATER TEMPERATURE CONTROL with SAFEGUARD Conforms to the following: ASSE 1017 California Lead Free Plumbing Law CSA B 125.3
More informationAgpro. Flush Valves TECHNICAL DATA / SPECIFICATIONS / APPLICATION GUIDE
TECHNICAL DATA / SPECIFICATIONS / APPLICATION GUIDE www.agprousa.com Over 20 types to satisfy all your flushing needs. Agpro Flush Valves are fully operational units designed for one purpose, flushing
More informationOperator Interface Enclosures
` www.hammfg.com s - NEMA 12, 13 Tara Plus 600 (135.2 lbs) 500 (112.4 lbs) Weight in Newtons 400 (90.1 lbs) 300 (67.4 lbs) 200 (45.1 lbs) 100 (22.5 lbs) 0.50 (1.6 ft) 1.00 (3.28 ft) Extension in Meters
More informationCash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified
Cash Valve PILOT OPERATED BACK PRESSURE VALVE ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 01 Certified KP HIGH CAPACITY PILOT OPERATED BACK PRESSURE VALVE DESCRIPTION The Cash Valve Type KP is a pilot
More informationETL listed for installations within 5 ft. (1.5M) of outer edge of water
Fiberstars Light Streams Mini Laminar Installation Manual (LSML) 3072091 ETL listed for installations within 5 ft. (1.5M) of outer edge of water 79-15056-00 Rev. A Page 1 of 6 SAVE THESE INSTRUCTIONS!
More information1 Exam Prep. Tabs and Highlights
1 Exam Prep NFPA 14: Standard for the Installation of Standpipe and Hose Systems Tabs and s These 1 Exam Prep tabs are based on the NFPA 14: Standard for the Installation of Standpipe and Hose Systems,
More informationAccu-Tab Systems 2000 P Series by Axiall Corporation
Accu-Tab Systems 2000 P Series by Axiall Corporation Installation and Operating Instructions Models 2075 P 2150 P For NSF/ANSI-Standard 61 NSF STANDARD 61 applications use NSF/ANSI Standard 60 listed Axiall
More informationG REQUIRMENTS FOR BRANCH LINES SUPPLYING MULTIPLE REGULATORS AND / OR METERS. 3 and Gas Blue Book
LAST REVIEW DATE: REVIEW CYCLE: 12/4/12 5 Years SPECIFICATION: G-703-0 TITLE: REQUIRMENTS FOR BRANCH LINES VOLUME: 3 and Gas Blue Book REVISIONS: (See ) This specification is being issued for the first
More informationConfined Space Hazard Identification & Risk Assessment Form
Date of assessment: Name of person(s) doing assessment: Name(s) of Qualified Person Location of space: Description of Space Description of Space: Wet Well Dry Well Valve Outlet/Inlet Tank PRV Manhole Box
More informationASAHI/AMERICA EFFECTIVE: 12/01/08. Dimensional Guide. Halar (E-CTFE) Piping & Valves
ASAHI/AMERICA EFFECTIVE: 12/01/08 al Guide Halar (E-CTFE) Piping & Valves Halar al Guide Pipe 5 meter-16.4 length da(od) s Asahi in in part# 1/2" 20 SDR 21 0.79 0.07 5501005 3/4" 25 SDR 21 0.99 0.07 5501007
More informationENGINEERING DATA. Engineering Data
ENGINEERING DATA Engeerg Data 599 Average Depth 3.5 ft. ESTIMATING TOTAL GALLONS IN A POOL OR SPA Length 24 ft. Dia. Width Depth (deep) Depth (shallow) Radius 2 x 3.14 x A.D. x 7.5 = Gallons 12 x 12 x
More informationInstallation Instructions
Installation Instructions Splashdown Fountain The Splash Down telescoping fountainhead comes in two sizes: the SD22 for use in water depths from 6 to 24 inches and the SD44 for use in water depths of 25
More informationTECHNICAL DATA NOTICE
Page 1 of 5 1. DESCRIPTION FomTec BFZ Inductors are used to mix foam concentrate with water when the foam concentrate is supplied from a tank at atmospheric pressure. The BFZ inductor can be installed
More informationEN00 Pre-Instructional Survey
EN00 Pre-Instructional Survey Name: Date: 1. At 433 degrees F, a type J thermocouple with a 3 degree F reference junction will produce an output in millivolts that is most nearly to: a. 9.04 b. 10.51 c.
More informationWastewater combination air valve in stainless steel AISI 316 Mod. SCS
Wastewater combination air valve in Mod. SCS The air valve guarantees the proper operation of sewage/industrial lines allowing the entrance of large quantity of air in case of pipe bursting or draining,
More informationBlue Points 1 ¼ WELL POINT INSTALLATION INSTRUCTIONS
Blue Points 1 ¼ WELL POINT INSTALLATION INSTRUCTIONS This brochure is designed to provide step-by-step instructional assistance to the individual who wishes to install a shallow water well system for residential
More informationPressure Compensating (PC) Spray Stakes
N E T A F I M U S A Pressure Compensating (PC) Spray Stakes Automated Watering Systems for Large Container Production Improve Plant Quality and Conserve Resources 1 or More Good Reasons to Choose Netafim
More informationPTS1120TSJB PTS2120TSTSJB
Engineering & Manufacturing Solutions Specifications: 18 gpm (68.0 lpm) Nominal Capacity. Rated up to 3000 psi (207 bar). Port Sizes: -Inlet/Outlet #12 SAE. -Work Ports #10 SAE. 10 Micron Filtration Recommended.
More informationInjection Systems INSTALLATION AND OPERATING GUIDE HI FLO VERTICAL TANK SYSTEMS
TM INSTALLATION AND OPERATING GUIDE HI FLO VERTICAL TANK SYSTEMS When the HI-FLO Metering Head is attached to a tank, the tank will be pressurized to the same pressure as the irrigation system. Before
More informationJoint Expo 2012 February 7-8, 2012 BASIC HYDRAULICS
Tim Sullivan, P.E. Hubbell, Roth & Clark, Inc. Outline Pressure Hydraulic Energy and Head Losses System-Pump Curves Concepts of hydraulics as they relate to Operators and Mechanics Outline Good News Bad
More informationTECHNICAL ACCESSORIES
A.R.I. VALVES S-050P AIR PLASTIC RELEASE 16 BAR Automatic Component A.R.I patent, Rolling Seal Mechanism: Dramatically reduces the possibility of obstruction by debris. Discharges high air flow rates upto
More informationSIZING OF WATER PIPING SYSTEM
SIZING OF WATER PIPING SYSTEM (This appendix is informative and is not part of the code.) SECTION AP101 GENERAL AP101.1 Scope. AP101.1.1 This appendix outlines two procedures for sizing a water piping
More informationCable Pressurization Buffering
Cable Pressurization Buffering What This Practice Is About Introduction This practice describes the various buffering practices that are used to protect the integrity of the pressurized cable network during
More informationTorque Specifications
SENR3130-10 Torque Specifications All Caterpillar Products S/N From the library of Barrington Diesel Club CONTENT General Information 01/07/2005 Introduction to Torque 01/07/2005 Torque-Turn 01/07/2005
More informationPanaFlow MV82. Insertion Style Multivariable Flowmeter. GE Measurement & Control. Key Benefits. Applications
GE Measurement & Control PanaFlow MV82 Insertion Style Multivariable Flowmeter Key Benefits Multivariable vortex flowmeter for measuring volumetric flow, temperature, pressure, density, and mass flow using
More informationTest Report. for Healy Science Incubator Supply on the bow of the USCGC Healy. Version Date: February 6, Instrument Lab
Test Report for Healy Science Incubator Supply on the bow of the USCGC Healy Version Date: February 6, 2009 Author(s): Instrument Lab Lamont-Doherty Earth Observatory of Columbia University 1 Palisades,
More informationMSC Guidelines for Bilge and Ballast Systems
S. T. Brady, CDR, Chief, Engineering Division References: a. Except as provided below, all vessels need to meet CFR 56.50-50 (bilge and ballast piping) and 56.50-55 (bilge pumps). b. Tankships (Subchapter
More informationOVERVIEW. Flow Coefficient C v. Operating Conditions. Specific Gravity
VERVIEW This valve sizing software program is based on the use of nomenclature and sizing equations from ISA Standard S75.01 and IEC Standard 534-2. The sizing equations are based on equations for predicting
More informationV248 Series 3-Way Pressure-Actuated. Water-Regulating Valves for High-Pressure
V248 Series 3-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants The V248 Series 3-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants regulate water
More informationPRODUCT SERIES: A-SF-3000BD
CONTINENTAL NH3 PRODUCTS INSTALLATION, OPERATION, REPAIR AND MANTINANCE INSTRUCTIONS PRODUCT SERIES: A-SF-3000BD ATTENTION: Please follow all of the instruction in this manual carefully and read the entire
More informationConsult with manufacturers concerning permeation of the pipe walls, jointing materials, valve seats, etc.
Design Manual Chapter 4 - Water Mains 4C - Facility Design 4C-1 Facility Design A. General Water mains and appurtenances, including hydrants and valves, should be provided along all streets including connections
More informationpvc well casing & drop pipe
C e r t a i nte e d pvc well casing & drop pipe P V C We l l P r o d u c t s Sure Fit PVC well casing and drop pipe have gained broad acceptance since their introduction almost 40 years ago. Today, due
More informationConsider the design of a central chilled water cooling system for a clubhouse and
EXAMPLE CD10-1 Consider the design of a central chilled water cooling system for a clubhouse and residential lodges for a prestigious golf club. The clubhouse is large with a 75 ton cooling load. It is
More informationSIZING OF WATER PIPING SYSTEM
SIZING OF WATER PIPING SYSTEM The provisions contained in this appendix are not mandatory unless specifically referenced in the adopting ordinance. E101.1 Scope. SECTION E101 GENERAL E101.1.1 This appendix
More informationthen the work done is, if the force and the displacement are in opposite directions, then the work done is.
1. What is the formula for work? W= x 2. What are the 8 forms of energy? 3. Write the formula for the following: Kinetic Energy Potential Energy 4. If the force and the displacement are in the same direction,
More informationWhen the pressure is on, turn to our high-pressure pumps
When the pressure is on, turn to our high-pressure pumps When you re pumping in a pressurized situation, you need more power than a standard airoperated double diaphragm pump can deliver. That s where
More informationF05MSV-N* CONTINENTAL HYDRAULICS FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK F05MSV-N* - FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK
CONTINENTAL HYDRAULICS F05MSV-N* FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK F05MSV-N* - FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK 5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: 952.895.6400
More informationRelief Systems. 11/6/ Fall
Relief Systems 1 Relief Scenarios o A single relief event requires a particulate vent area and valve size o Relief scenarios are determined based on a PHA o For each scenario, a vent area is calculated
More informationSIZING AND CAPACITIES OF GAS PIPING
SIZING AND CAPACITIES OF GAS PIPING A.1 General piping considerations. The first goal of determining the pipe sizing for a fuel gas piping system is to make sure that there is sufficient gas pressure at
More information1700ESL Kamvalok Coupler
PART #H32138PA November 2008 1700ESL Kamvalok Coupler OPW Transport Series Dry Disconnect Couplings are considered the standard of the industry. For use on multi-compartment petroleum, solvent and chemical
More informationPULSATION DAMPENER / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS
PULSATION / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS FUNCTIONS: 1. Pulsation Dampener smooths pump flow 2. Surge Suppressor absorbs shocks and vibrations 3. Water Hammer Arrestor eliminates
More informationChapter 14 Water Shuttle Operations
1. Which of the following statements about water shuttle operations is TRUE? A. Water shuttle operations may create a dramatic hose failure B. Water shuttle operations are safer than relay pumping operations
More informationFlow Sensors & Hydrometers Specification Sheet
Baseline Flow s and Hydrometers Baseline s smart flow sensors and hydrometers are two-wire ready flow measurement and control devices that are pre-programmed with the correct K and Offset values. In addition,
More informationTechnical Service Bulletin 10001
Technical Service Bulletin 10001 THIS APPLIES TO ALL AIR SPRINGS USED IN USSC LLC AIR SUSPENSIONS Issue: USSC has made a change to the air spring used in operator seat suspensions. This bulletin will identify
More informationESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of 14 Hydraulics Revised
DRIVER OPERATOR Page 1 of 14 HYDRAULICS Hydraulics applied in the dynamic fire ground environment is an art that comes with study and experience. The following describes the factors that must be mastered
More information