TECHNICAL MANUAL DHR80 LED. Den Haan Rotterdam
|
|
- Lorraine Murphy
- 6 years ago
- Views:
Transcription
1 TECHNICAL MANUAL DHR80 LED SIN CE 922 Den Haan Rotterdam
2 TABLE OF CONTENTS Disclaimer Technical data Product photos Dimensions Available models Exploded view - base mounting Electrical specification Electrical spec. manoeuvring Lifetime control Positioning sidelights Positioning all-round lights Mounting Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 0 Page Page 2 Page 3 DISCLAIMER Den Haan Rotterdam B.V. is not responsible or liable for (in)direct or consequential damages from the use or application of this equipment and manual. All illustrations in this manual are for illustrative purposes only. This manual is not intended to cover every possible detail about the product and its maintenance. Den Haan Rotterdam B.V. does not assume responsibility or reliability for actual use based on the text, illustrations and diagrams. Copyright, Den Haan Rotterdam B.V. Version 2.0 December 204 This document contains proprietary information that is protected by copyright. All rights reserved. 2
3 TECHNICAL DATA Application: Ÿ As Navigation light for all sea-going vessels with a length of more than 20 metres Ÿ As Navigation light for all vessels in Rhine and European inland navigation Ÿ As general signalling light In compliance with: Ÿ International Regulations for Preventing Collisons at Sea; COLREG 72 and latest amendments Ÿ Rhine and European inland navigation rules Ÿ the Directives 96/98/EC and 82/74/EC, following the European standard: EN 4744 (2005) AC(2006), Inland navigation vessels and sea-going vessels - navigation light Materials: Ÿ Housing: Seawater resistant aluminium, hard anodised, black Ÿ LED driver: Epoxy potted Ÿ Screen: Seawater resistant aluminium, anodised black Ÿ Lens: Borosilicate glass Ÿ Base: Polyamide black Min. visibilty: Sector lights Starboard - bright Port - bright Masthead - bright Stern - bright Towing - bright 6NM All-round - bright Manoeuvring - bright Green - bright Yellow - bright Electrical insulation class: I, (grounded) / III Powersupply: 24VDC -20% +30% Protection class: IP X6 life time: 50,000 Hours Operation temperature: -25 C up to +55 C Mounting: Base 3 5NM
4 PRODUCT PHOTOS 4
5 DIMENSIONS 55 Ø All dimensions in mm. 5
6 AVAILABLE MODELS Power Art. Code Sector lights Min. Visibility Colour Starboard Port Masthead Stern Towing 6 NM Green Yellow Special sector lights Min. Visibility Colour Power Art. Code Stern - (Suez light) 6,5 W All-round lights Min. Visibility Colour Power Art. Code Green Yellow 5 NM Green Yellow 3 W 6,5 W All-round lights, screened Min. Visibility Colour Power Art. Code Green Yellow Green Yellow 6,5 W Manoeuvring 6 6,5 W 6,5 W
7 EXPLODED VIEW - BASE MOUNTING Item Part 2 3 Cover Seawater resistant aluminium, hard anodized black Gasket lens DHR80 Neoprene - shore 30 Screen Seawater resistant aluminium, anodized black Sidelights Masthead Stern and Towing 80 Glass Tube Borosilicate glass Seawater resistant aluminium Heatsink Triangle (Sector and All-round) Hexagon (Masthead) LED PCB MC-PCB, aluminum.55 mm Starboard / All-round green Led platinum dragon Green Port / Stern / All-round red Led golden dragon Masthead Led Oslon black flat Stern / All-round white / Manoeuvring Led golden dragon Led golden dragon Towing / All-round yellow Yellow Housing Seawater resistant aluminium, hard anodized black Plug M20x,5 Polyamide Gasket 28x20x,5 PTFE Cable gland M20x5 Body: Polyamide - Seal: Neoprene Gasket 28x20x,5 Paper LED driver PCB - Potting matrial: Polyurethaan 500mA All-round white, green and yellow / Starboard / Stern / Towing 700mA All-round red / Port 000mA Masthead 700mA Signal Manoeuvring Base plate gasket Neoprene - shore 30 Base plate Polyamide black Membrane Vent Body: Polyamide - Membrane: eptfe Material Quantity 7 2 Number
8 ELECTRICAL SPECIFICATION Power main 24VDC Power spare 24VDC LED DRIVER (MAIN) Output LED DRIVER (SPARE) Output Galvanic separation cable ferrule Main 24VDC PE PE - + cable ferrule + 2- Spare 24VDC 3-5 LEDS cable ferrule + 2- PE LEDS cable ferrule LED driver LED PCB Grounding (PE) is not required, but gives better ESD/EMI protection Navigation light Power supply Starboard Port Masthead Stern Stern red (Suez light) Towing All-round white All-round green All-round red All-round yellow 500mA 700mA 700mA 500mA 700mA 500mA 500mA 500mA 700mA 500mA Nomale voltage 24VDC Typical wattige* Typical current* 4,5W 6,5W 6,5W 4,5W 6,5W 4,5W 4,5W 4,5W 6,5W 4,5W 90mA 260mA 690mA 90mA 260mA 90mA 90mA 90mA 260mA 90mA * Depends on temperature and LED production series 8 Minimum operating current Error current Inrush current >40mA <0mA 20A
9 ELECTRICAL SPEC. MANOEUVRING LED DRIVER Power 24VDC Output 3 LEDS Output 3 LEDS Control signal 24VDC PE +24VDC OVDC PE - + Control Signal cable ferrule + 2- PE - + cable ferrule cable ferrule + 2- cable ferrule LED driver LED PCB Grounding (PE) is not required, but gives better ESD/EMI protection Navigation light Power supply Nomale voltage Typical wattige* Typical current* Minimum operating current Error current Inrush current Manoeuvring 700mA 24VDC 3W 540mA >40mA <0mA 20A * Depends on temperature and LED production series LIFETIME CONTROL Measurements of the navigation light and specifications retrieved from the OEM, show a conformity with the minimum requirements of COLREG 72 at an operational lifetime of hrs. To guarantee a proper use of the LED navigation lights, we as a manufacturer advise the following: Ÿ Use the navigation light in combination with a DHR-specified control system, which monitors the status and operational life time of each individual navigation light Ÿ Each navigation light needs to undergo a quality check at least every 5 years of use to verify it still meets the requirements of COLREG 72 9
10 POSITIONING SIDE LIGHTS Paint the inside matt black K Parallel to the keel line ,5 2 2,5 8 J H 8 48 L L H K J [mm] Disclaimer: Ÿ The minimum luminous intensity requirements in the forward direction are only guaranteed if the sidelights are mounted in accordance with this drawing and table. Ÿ This is an illustration to indicate the dimentions of the inboard screens, relative to the keel line of the vessel. By no means may this image be used to determine the position of the sidelights on the vessel. For positioning the lights at the vessel always check for compliance with COLREG 72 or local rules. 0
11 POSITIONING ALL-ROUND LIGHTS S [mm] D [mm] 6 D S Diagram for choosing the minimum distance between obstacle and mounting plate. Disclaimer: This is an illustration to indicate the position of the all-round light so not to be obscured by mast, topmasts or structures within the angular sector of more than 6 degrees. By no means may this image be used to determine the position of the all-round lights on the vessel. For positioning the lights on the vessel always check for compliance with COLREG 72 or local rules.
12 MOUNTING Bolt M0 x (40 + M) Washer M0 Lantern base M Mounting plate // 00,5 Washer M0 Nut M0 All dimensions in mm. Mounting plate The mounting plate for navigation lights should be at least 5 mm thick and should not exceed a parallelism of // 00,5. Fasteners Ÿ The permissible torque should be 8 Nm Ÿ Use only A4-grade stainless steel Important Do not paint or use any other chemical for the lanterns, clean only with fresh water. 2
13 ADVANCED MARITIME SIGNALLING SOLUTIONS SIN C E 922 Den Haan Rotterdam Fascinatio Boulevard VA Capelle a/d IJssel T +3 (0) E Sales@dhr.nl
DHR40 LED TECHNICAL MANUAL
DHR0 LED TECHNICAL MANUAL SIN CE 9 Den Haan Rotterdam TABLE OF CONTENTS Disclaimer Technical data Dimensions Available models Exploded view - base mounting Exploded view - side mounting Exploded view -
More informationTECHNICAL MANUAL DHR80 LED. Den Haan Rotterdam MED96/98/EC
TECHNICAL MANUAL DHR80 LED MED96/98/EC SINCE 1922 Den Haan Rotterdam DISCLAIMER Despite constant care and attention DHR puts in its manuals it is still possible that information in this manual is incomplete
More informationTECHNICAL MANUAL DHR60 LED. Den Haan Rotterdam MED96/98/EC
TECHNICAL MANUAL DHR60 LED MED96/98/EC SINCE 1922 Den Haan Rotterdam DISCLAIMER Despite constant care and attention DHR puts in its manuals it is still possible that information in this manual is incomplete
More informationTECHNICAL MANUAL DHR40 LED. Den Haan Rotterdam MED96/98/EC
TECHNICAL MANUAL DHR40 LED MED96/98/EC SINCE 19 Den Haan Rotterdam DISCLAIMER Despite constant care and attention DHR puts in its manuals it is still possible that information in this manual is incomplete
More informationTECHNICAL MANUAL DHR70N. Den Haan Rotterdam
TECHNICAL MANUAL DHR70N SINCE 1922 Den Haan Rotterdam DISCLAIMER Despite constant care and attention DHR puts in its manuals it is still possible that information in this manual is incomplete or incorrect.
More informationTECHNICAL MANUAL DHR55N. Den Haan Rotterdam MED96/98/EC
TECHNICAL MANUAL DHR55N MED96/98/EC SINCE 1922 Den Haan Rotterdam DISCLAIMER Despite constant care and attention DHR puts in its manuals it is still possible that information in this manual is incomplete
More informationTECHNICAL MANUAL. DHR70N Polar. Den Haan Rotterdam
TECHNICAL MANUAL DHR70N Polar SINCE 1922 Den Haan Rotterdam WARNING! - Turn power off before inspection, installation or removal - Keep combustible materials away from lamp - Allow lamp/fixture to cool
More informationINSTRUCTION MANUAL Pressure Relief Device LPT
INSTRUCTION MANUAL Pressure Relief Device LPT 5COV475800 LPT REV00 CONTENT: 1 SAFETY 1.1 Safety instructions 2 1.2 Specified applications 2 1.3 Safety notes on the equipment operation 2 2 PRESSURE RELIEF
More informationDatasheet liniled Handrail 42.4 V1017 IK10. F RoHS FROST CLEANING AGENTS RESISTANT UV RESISTANT
Datasheet liniled Handrail 42.4 V1017 F RoHS IP40 IP68 IK10 AISI 316 UV RESISTANT FROST CLEANING AGENTS RESISTANT Handrail 42.4 Product information Technical specifications Product specifcations Required
More informationDatasheet liniled Handrail 48.3 V1017 IK10 IP68. F RoHS IP40/IP65 FROST CLEANING AGENTS RESISTANT UV RESISTANT
Datasheet liniled Handrail 4 V1017 F RoHS IP40/IP65 IP68 IK10 AISI 316 UV RESISTANT FROST CLEANING AGENTS RESISTANT Handrail 4 Product information Technical specifications Product specifcations Required
More informationOperating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073
Operating instructions Safety Rope Emergency Stop Switches UK ZB0052 / ZB0053 ZB0072 / ZB0073 7390878 / 02 03 / 2011 Contents 1 Safety instructions...3 2 Installation / set-up...4 2.1 Applications...4
More informationMounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity
Type 4708-45 Supply Pressure Regulator with increased air capacity Translation of original instructions Mounting and Operating Instructions EB 8546-1 EN Edition March 2016 Note on these mounting and operating
More informationMagnetic level switch type MR783 Instruction Manual
Magnetic level switch Magnetic level switch type MR783 1. DESCRIPTION page 3 1.1 Operation page 3 1.2 Application page 3 1.3 Description page 3 2. SPECIFICATIONS page 3 2.1 Service Conditions page 4 2.2
More informationOperating Instructions
LPL Series LED Pendant Lighting Operating Instructions IM0102 COOPER Electronic Technologies (Shanghai) Co., Ltd. No. 955 Shengli Road, East Area of Zhangjiang High-Tech Park, Shanghai 201201 China 1.
More informationSITRANS P measuring instruments for pressure
SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and
More informationInstallation and Operating Instructions Bypass Flow Meter DST
Installation and Operating Instructions Bypass Flow Meter DST DST_gb_A4_1.0.doc Version 1.0 1 von 10 Contents 1. Foreword... 3 2. Safety... 3 2.1. Symbol and meaning... 3 2.2. General safety directions
More informationGEMS SENSORS & CONTROLS
GEMS SENSORS & CONTROLS OPERATING & INSTALLATION INSTRUCTIONS 31XX / 32XX SERIES PLEASE READ CAREFULLY BEFORE INSTALLING Part Number: 560550-0076 Issue: E INTRODUCTION Series 3100/3200 high output pressure
More informationPLAQUE MFM0680 UNDERWATER LIGHT. Operating Instructions
PLAQUE MFM0680 UNDERWATER LIGHT Operating Instructions CONTENTS Preface... 3 Features... 3 Precautions... 3 Controls and Connectors... 4 Underwater Light PLAQUE MFM0680... 4 Power Supply Unit MPS021000
More informationPrewired position switches FA series
2 Prewired position switches FA series Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 51 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable lever 41 45
More informationSingle and double acting, magnetic, self-centering Bores: ø 16, 20, 25, 32, 40 mm
> Series CGPT self-centering parallel grippers with T-guide Series CGPT self-centering parallel grippers with T-guide Single and double acting, magnetic, self-centering Bores: ø 6, 20, 25, 32, 40 mm New
More informationE10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1.
> Explosion protection type "Increased safety" > Degree of protection IP68 > Ex e and Ex i versions > Integrated blind plug (accessory) for closing unused cable glands > Cable diameter ranges from 1 to
More informationPressure Measurement Single-range transmitters for general applications
Siemens AG 07 Overview Function U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/ Equipotential bonding Diaphragm The pressure
More informationRule 21 - Definitions
(a) "Masthead light" means a white light placed over the fore and aft centreline of the vessel showing an unbroken light over an arc of the horizon of 225 degrees and so fixed as to show the light from
More informationPressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar
Pressure relief valve DHV 7 DN 5-80: 0,5-0 bar, DN 5-00: 0, - bar, DN 00: 0,5 - bar Advantage for high pressure stability reliable reduction of pressure peaks and pulsations pressure setting possible at
More informationCONUS MSR0680 UNDERWATER LIGHT. Registered Community Design. Operating Instructions
CONUS MSR0680 UNDERWATER LIGHT Registered Community Design Operating Instructions CONTENTS Preface... 3 Features... 3 Precautions... 3 Controls and Connectors... 4 Underwater Light CONUS MSR0680... 4 Power
More informationPLAQUE MFM18240 UNDERWATER LIGHT. Operating Instructions
PLAQUE MFM18240 UNDERWATER LIGHT Operating Instructions CONTENTS Preface... 3 Features... 3 Precautions... 3 Controls and Connectors... 4 Underwater Light PLAQUE MFM18240... 4 Power Supply Unit MPS061000
More informationPULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING
PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING Please Note: Ranges above 500mbar are designed and manufactured in accordance with sound engineering
More informationOperating Instructions
Operating Instructions Light-metal Ex d enclosures / flameproof enclosure > 8265/0 Empty enclosure > 8265/4 Control panel, integrated in Ex e enclosure > 8265/5 Control panel Table of Contents 1 Table
More informationK13.12 FACE FIXED PANIC EXIT DEVICE K13 DOORS
K13 DOORS K13.12 FACE FIXED PANIC EXIT DEVICE 01.03.2018 Waregemstraat 5-9870 Zulte - Belgium - T. +32 9 388 88 81 - F. +32 9 388 88 21 - commercial@sobinco.com - www.sobinco.com CONTENTS 1. Base set n
More informationCable entries. Contents. Cable entries. Cable entries Introduction L.2 L.1. Standard cable glands - Plastic L.5. Standard cable glands - Brass L.
Contents Introduction.2 Standard cable glands - Plastic.5 Standard cable glands - Brass.7 EMC cable glands.14 Standard cable glands - Stainless steel.16 Cable glands for Ex applications - Brass.17 Adaptors.18
More information4/2 way Pneumatic Solenoid Valve
4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11
More informationCFSW. Hinges with built-in safety multiple switch
CFSW. Hinges with built-in safety multiple switch ELESA Original design technical informations Material - Hinge body: self-extinguish high-rigidity SUPER-technopolymer, black colour. Resistant to solvents,
More informationAir Sensor. FCS Ex. Manual. AQ Elteknik AB
Air Sensor FCS Ex Manual AQ Elteknik AB Air Sensor Model FCS Ex Manual version 2.0 Oct 2010 AQ Elteknik AB AQ Elteknik AB Air Sensor Manual 2 Table of contents 1. Manufacturer information... 4 Manufacture
More information2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure
Z series for gage pressure Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection
More informationa. On the centerline of the T-top b. On the aft starboard corner of the deck c. On the aft deck as close to centerline as possible
1. A 22 fishing boat has separate side lights due to an anchor roller at the bow. Where should the all-round light be positioned for use in international waters? a. On the centerline of the T-top b. On
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter
ABB MEASUREMENT & ANALYTICS DATA SHEET WaterMaster FEW530 Electromagnetic water meter 2 WATE RMASTE R F E W 530 ELECT ROMAGNE TIC WATE R ME TE R DS/FE W530/FE T3 -E N RE V. A Measurement made easy Cost
More informationPosition switches FP series
A Position switches FP series Selection diagram 0 08 8 9 0 0 0 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fiber glass rod gasket sphere sphere adjustable lever safety adjustable lever
More informationPressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview
f gauge pressure Siemens AG 010 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection
More informationCFSW. Hinges with built-in safety multiple switch
CFSW. Hinges with built-in safety multiple switch ELESA Original design Elesa Standards Main dimensions Fitting Weight Code Description L B f ±0.2 f 1 ±0.2 H h 1 h 2 d 3 d 4 C [Nm]# g 426601 CFSW.110-6-2NO+2NC-C-A
More informationOperating Instructions Melt Pressure Sensor
Operating Instructions Melt Pressure Sensor DA Certified to ISO 9001:2008 Please read this instruction manual carefully before installing the transducer 1 Contents: 1. Introduction 2. Operating range and
More informationARCA cabinet NEW. High performance polycarbonate cabinet. Protection in demanding environments
ARCA cabinet NEW High performance polycarbonate cabinet Protection in demanding environments NEW Fibox ARCA Fibox ARCA non corrosive electrical cabinets for use in extremely harsh and demanding environments
More informationDMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.
Pressure Transmitter for Marine and Offshore Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0. % FSO Nominal pressure from 0... 40 mbar up to 0... 0 bar Output signals -wire:
More informationPressure Measurement Single-range transmitters for general applications
Siemens A 207 Overview Application The SITRANS P Compact pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials
More informationGas density monitor With integrated transmitter Model GDM-100-TI
SF 6 gas solutions Gas density monitor With integrated transmitter Model GDM-100-TI grid Products WIKA data sheet SP 60.05 for further approvals see page 5 Applications Gas density monitoring of closed
More informationA-100, AD, CD, CD2M and PD Membrane level indicator for solids. Operating Instructions. Safety instructions Operating instructions
,, CD, and PD Membrane level indicator for solids Operating Instructions Index Page Safety instructions................................................................................... 02 Operating instructions
More informationT-CITY. Waterproof protection for LED lighting
Waterproof protection for LED lighting The T-CITY series was designed as LED lighting device for CNC machines. Elegant and compact, the T-CITY has just 38 mm diameter, making it suitable to fit small spaces.
More informationInstallation & Maintenance Instructions TEC-11N TIMER. Analogue electronic timer 02/09
Installation & Maintenance Instructions TEC-11N TIMER Analogue electronic timer 02/09 GENERAL OPERATION The TEC-11N timer is produced using SMT (Surface Mounting Technology), ensuring improved performance
More informationMV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:
MV-01 2/2-way Solenoid Valve for Fluids Description: Features / Nominal diameters 1/4-2 / Pressure up to 10 bar / 24 V DC and all common AC variants / Forced-lifting The pilot-controlled full-way valve
More informationSG36KTL-M Quick Installation Guide. 1 Unpacking and Inspection
SG36KTL-M Quick Installation Guide This guide provides a general instruction of the installation procedures of SG36KTL-M. In no case shall this guide substitute for the user manual or related notes on
More informationAVK SERIES 601, 602, 603 & 605 UNIVERSAL COUPLINGS, ADAPTORS & END CAPS INSTALLATION, OPERATION & MAINTENANCE MANUAL
Instruction for use Thank you for selecting an AVK product. With correct use, the product is guaranteed to deliver a long and reliable service. This manual has been prepared to assist you with the installation,
More informationPressure Reducing Valve DMV 750 set range: bar
Pressure Reducing Valve DMV 750 set range:.0-6.0 bar Advantage pressure setting possible at any time, also during operation hermetically sealed by valve diaphragm high level of operating safety and long
More informationOperating Instructions
Operating Instructions Ex d Enclosures in Light Metal / Flameproof Encapsulation > 8265/0 Empty Enclosure > 8265/4 controller, installed in Ex e enclosure > 8265/5 controller Contents 1 Contents 1 Contents...2
More informationPressure relief valve DHV 716 set range: 0,5-10,0 bar
Pressure relief valve DHV 7 set range: 0,5-0,0 bar Advantage pressure setting possible at any time, also during operation optimum monitoring valves high reproducibility of the set pressure high level of
More informationliniled Handrail liniled Handrail Number of LEDs
liniled Handrail liniled Handrail Number of LEDs Light output Beam angle Dimensions Protection Voltage Power Finish Material Warranty Notes 7 per section / 35 per metre (Deco) 7 per section / 35 per metre
More informationPRODUCT SUPPORT MANUAL YACHT BEAM 6M Searchlight Remote Control System with Joystick Remote Control Panel
PRODUCT SUPPORT MANUAL YACHT BEAM 6M Searchlight Remote Control System with Joystick Remote Control Panel The Yacht Group - 4545 Ponce de Leon Blvd. Coral Gables FL 33146 Tel. 305.667.5811 - Fax. 305.663.5551
More informationGA24 Technical Datasheet
GA24 Technical Datasheet Variable-area flowmeter Sturdy construction for several applications Local indication without auxiliary power Replaceable mounting parts KROHNE CONTENTS GA24 1 Product features
More informationMounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator
Self-operated Pressure Regulators Type 2357-31 Pressure Build-up Regulator with safety function and integrated excess pressure valve Type 2357-31 with non-return unit at port C Ports A and B with soldering
More informationMECAIR CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS PRODUCT LEAFLET
CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS GENERAL CHARACTERISTICS CONSTRUCTION FEATURES ENCLOSURE OPERATING TEMPERATURE 20 C/+60 C COVER Diecast aluminium (anodised) WEIGHT CSN 5 3.5 kg CSN 8 5 kg CSN
More information1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition
Siemens AG 07 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure
More informationType 4708 Supply Pressure Regulator
Type 478 Pressure Regulator Application pressure regulators used to provide pneumatic measuring and control equipment with a constant air supply Set point ranges. to. bar ( to 4 psi). to bar (8 to 9 psi)
More informationType Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN
Type 4708-45 Pressure Regulator for increased air capacity Fig. 1: Type 4708-45 Pressure Regulator Mounting and Operating Instructions EB 8546-1 EN Edition March 2010 Definition of the signal words used
More informationPull-rope emergency stop switch Type HENEX and SEGEX OPERATING INSTRUCTIONS
Pull-rope emergency stop switch Type OPERATING INSTRUCTIONS Legal Notice (Translation of the original) Document No.: 94.058 816.191 Pull-rope emergency stop switch, Type HENEX and SEGEX Product number:
More informationAutomatic Twin Greasing System
Parts Manual Automatic Twin Greasing System YOUR EFFICIENCY IS OUR CHALLENGE All rights reserved. No part of this manual may be copied and/or published by means of printing, photocopying, microfilm or
More informationType 4708 Supply Pressure Regulator
Type 478 Pressure Regulator Application pressure regulator used to provide pneumatic measuring and control equipment with a constant air supply Set point ranges. to.6 bar ( to 4 psi) or. to 6 bar (8 to
More informationManual winch MANISTOR 100 and 200
Manual wall winch Manual winch MANISTOR 100 and 200 Instruction manual UK 173-192.10-3 PRODUCT DEVELOPED AND MANUFACTURED ACCORDING TO NF EN 13157 STANDARD REGISTERED DESIGN To ensure the constant improvement
More informationFloodlight LED. Series Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN
Floodlight LED Operating instructions Additional languages www.stahl-ex.com General Information Contents 1 General Information...2 1.1 Manufacturer...2 1.2 Information regarding the operating instructions...3
More informationPressure Reducing Valve DMV 755
Pressure Reducing Valve DMV 755 Nominal size DN 10 50 Nominal size 3/8 2 Nominal pressure PN 10 bar Features pressure setting range 1 to 9 bar control valve for reliable reduction of system pressures to
More informationFurther technical information is available on
1 of 5 Manufacture address : Bartec Technor AS Dusavikveien 39 4007 Stavanger Norway Further technical information is available on www.bartec-technor.no Note on instructions When working in hazardous areas,
More informationFloodlight LED. Series Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN
Floodlight LED Operating instructions Additional languages www.r-stahl.com Contents 1 General Information...3 1.1 Manufacturer...3 1.2 Information regarding the operating instructions...3 1.3 Conformity
More informationPressure relief valve DHV 725 set range: 0,2-10,0 bar
Pressure relief valve DHV 75 set range: 0, - 0,0 bar Advantage pressure setting possible at any time, also during operation optimum monitoring valves high reproducibility of the set pressure high level
More informationK0709 Quick-fit couplings
Joints 1067 K0709 Quick-fit couplings with radial offset compensation external thread D1 SW SW1 application example: X max. D D 3 4 internal thread SW 3 4 2 SW1 D D Coupling part and claw in steel. Nut
More informationEX-RECESSED CEILING LIGHT FITTINGS
EX-RECESSED CEILING LIGHT FITTINGS RLF/RLF-INOX 250 18-58 W / RLF/RLF-INOX 250... N 18-36 W Metallic design for Zone 1 and Zone 21 The RLF... explosion-protected recessed ceiling light fittings with electronic
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-10
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well
More informationErection, maintenance and disposal Inverted installation. Zinc oxide silicone-housed surge arresters PEXLIM R-X, Q-X and P-X
Erection, maintenance and disposal Inverted installation Zinc oxide silicone-housed surge arresters PEXLIM R-X, Q-X and P-X 1 Important information The following instruction is valid for PEXLIM R-X, PEXLIM
More informationSG33KTL-M Quick Installation Guide. 1 Unpacking and Inspection
SG33KTL-M Quick Installation Guide This guide provides a general instruction of the installation procedures of SG33KTL-M. In no case shall this guide substitute for the user manual or related notes on
More information1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI
Siemens AG 06 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure
More informationNEW TYPE M PRESSURE RELIEF DEVICE
NEW TYPE M PRESSURE RELIEF DEVICE M PRESSURE RELIEF DEVICE ACCORDING TO EN 50216-5/A2 PATENTED 2 PRESSURE RELIEF DEVICE TYPE 50 M Section A-A 170 139 Transformer tank F 41.5 3 ø48.3 ø166 A P.R.D. TAG A
More informationMonitoring device NTS 30
P R O D U C T I N F O R M A T I O N Electronic level- and temperature monitoring device Monitoring device NTS 30 Contents Description Description... 2 Operating... 3 Design and electrical data... 4 Circuit
More informationInstruction Manual Differential Pressure Transmitter
DE13 Instruction Manual Differential Pressure Transmitter Table of Contents 1. Safety Instructions 2. Intended Applications 3. Product Description and Functions 4. Installation 5. Commissioning 6. Maintenance
More informationCP10 Sensor Installation and Maintenance Instructions
4030150/9 IM-P403-26 EMM Issue 9 CP10 Sensor Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Maintenance 5. Spare parts Copyright 2017
More informationMUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.
Installation Instructions manual MUELLER table of contents PAGE A-20814 Wall Type General Information 2 Technical Data/ Dimensions Installation 4-5 Maintenance 6 Parts 7 Indicator Post! WARNING: 1. Read
More informationSPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection
SPOOL VALVES pilot operated single/dual solenoid (mono/bistable function) ISO 07-8 mm - pad mounting body M connection x/ - / - / Series 0 ISO 07- (8 mm) FEATURES M connection on top of valve: reduces
More informationLED Directionals Helios LED light bars
LED Directionals Helios LED light bars Xenon strobe beacons 2012 Catalogue SAFETY AND WARNING LIGHTING Brought to you by a team with long experience in the development, manufacture and sale of flashing
More informationMounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type
Type 4708 Supply Pressure Regulators Translation of original instructions Type 4708-53 Type 4708-64 Type 4708-12 Mounting and Operating Instructions Edition March 2018 Note on these mounting and operating
More informationTA-FUSION-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics
TA-FUSION-P Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics IMI TA / Control valves / TA-FUSION-P TA-FUSION-P These innovative
More informationUNIK 5600/5700 Marine Certified Pressure Sensing Platform
GE Measurement & Control UNIK 5600/5700 Marine Certified Pressure Sensing Platform The new UNIK 5600/5700 carries marine certification for most zones on-board ship, as well as Intrinsically Safe certifications.
More informationMETEOR LSR36500 LIGHTING UNDERWATER POOL LIGHT. Operating Instructions
METEOR LSR36500 UNDERWATER POOL LIGHT Operating Instructions LIGHTING CONTENTS Preface...3 Features...3 Precautions...3 Components and Connectors...4 Installation...5 Controls...7 Appearance...8 Technical
More informationMZX. Three-Port Seat Valves SPECIFICIATIONS AND GUIDE TO SELECTION
01 These seat valves are of globe construction with a linear moving spindle and a modified parabolic characterised plug operating against the upper seat which controls flow quantity to suit the load. The
More informationLess power great performances
148 SMART SMART Less power great performances SMART is the answer to the increasing demand for both low energy consumption and high efficiency. Based on many years experience in road lighting, it offers
More informationPrewired position switches FA series
Prewired position switches Technical data Housing Made of metal, coated with baked epoxy powder 2 m wired cable with 5x0,5 mm 2 wires marked SEV and IMQ Protection degree: IP6 General data Ambient temperature:
More informationPressure Reducing Valve DMV 755 set range: 1,0-9,0 bar
Pressure Reducing Valve DMV 755 set range:,0-9,0 bar Advantage pressure setting possible at any time, also during operation high reproducibility of the set pressure high level of operating safety and long
More informationdatasheet M25S 24VDC motor Features & benefits
datasheet M25S 24VDC motor Features & benefits Slow Start, Slow Stop Starting from any position, the M25S starts very slow for a better quality feel of movement. The end position is smoothly approached
More informationOPTIBAR P 1010 C Technical Datasheet
Technical Datasheet Pressure transmitter with recessed diaphragm for general applications Wide variety thanks to modular design Measuring ranges up to 250 bar / 3750 psi High overload and temperature stability
More informationFEPA PNEUMATICALLY AND SOLENOID ACTUATED VALVES, ONE UNIT MOUNTED TYPE VPG
PNEUMATICALLY AND SOLENOID ACTUATED VALVES, ONE UNIT MOUNTED TYPE VPG TECHNICAL CHARACTERISTICS Number of ways / positions : 3/2, 3/3, 5/2, 5/3, 5/4 Nominal sizes (ND) : 4, 6, 9, 12 Medium : compressed
More informationOPTIPOW 105 OPTIPOW 105 ; MAIN PARTS. Our Ref: PSE, Bernt Andersson
Page 1 (6) Our Ref: PSE, Bernt Andersson OPTIPOW 105 OPTIPOW 105, the compact pulse valve for the Optipulse fabric filters of different types: is a result of many years of experiences within the fabric
More informationLTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc.
LTB013EN Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc. to IECEx scheme Subject to technical modification Bachofen AG Ackerstrasse 42
More informationE8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)
Pressure Sensor (Stainless Steel Diaphragm) CSM DS_E_3_1 Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications Incorporates double diaphragms consisting of SUS316L stainless
More informationManual Power relay SR853
Manual Power relay SR853 Rev. 0 SR853 manual page2 Safety Guidelines for explosion proof devices Application and Standards This instruction manual applies to explosion protected control systems of protection
More informationAir Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB
Air Sensor SAC Ex Manual AQ Elteknik AB ATEX Air Sensor SAC Ex ATEX Certified model Manual version 2.1 April 2014 AQ Elteknik AB 2 Table of contents 1. Manufacturer information... 4 Manufacture Declaration
More informationINTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the COLREG
INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES Interpretations of the COLREG CONTENTS COLREG1 Interpretation to COLREG 1972 Annex 1, Section 9 (b) Corr.1 Feb 2013 COLREG2 Interpretation to COLREG
More information