Application of CHE100 in Frequency Conversion Alteration of Air Compressor System

Size: px
Start display at page:

Download "Application of CHE100 in Frequency Conversion Alteration of Air Compressor System"

Transcription

1 Application of CHE100 in Frequency Conversion Alteration of Air Compressor System Abstract: This paper describes application of CHE100 in frequency conversion alteration of the air compressor system and introduces in detail the principle of the special controller for air compressor and its interaction with the frequency inverter and application. Keywords: frequency conversion, Modbus, air compressor 1. Introduction Air compressor is a kind of equipment that uses a motor to compresses air in the compressing chamber and brings the compressed air to a certain pressure. As a basic industrial installation, the air compressor has wide applications in almost all industrial fields such as metallurgy, machine manufacturing, mine, electric power, textile, petrochemical, light textile, etc. The electric energy consumption of air compressors accounts for 15% of all large scale industrial equipment (fan, pump, boiler, air compressor, etc.). Most air compressors have obvious inherent technical weaknesses due to their structure and principle. When the output pressure exceeds a certain value, it automatically opens the relief valve and idles the asynchronous motor. This seriously wastes energy. Moreover, the asynchronous motor tends to start and stop frequently. This affects the service life of the motor. The compressor has high starting current in power frequency mode. This has a high impact on the power grid and causes serious wear of the motor shaft and high maintenance of equipment. The working conditions are harsh and the noise level is high. The automation level is low. The adjustment of output pressure is realized by manually regulating the valve opening. This has the disadvantages of low regulation speed, large fluctuation, low stability and low accuracy. 2. Operating principle 2.1 Original working manner Operating principle of screw compressor Two parallel mated female and male rotors (or screws) turn in the cylinder and cause constant, periodic volume variation of the air filling between the teeth and grooves of the rotors. The air is sent from the suction side to the output side along the axial of the rotors. The whole process of suction, compression and exhaust of the screw compressor is realized in this way. The inlet and outlet of the air compressor are located on two ends of the housing respectively. The grooves of the female rotor and the teeth of the male rotor rotate under the driving of the main motor. Operating principle of piston compressor The motor drives the pulley and directly drives the crank via the coupling. The crank drives the collecting rod and piston rod and causes reciprocation of the piston in the cylinder of the compressor. In this way the piston compressor completes its suction, compression and exhaust and other processes and boosts the pressure of non- or low-pressure gas and outputs it to the accumulator. The piston assembly, inner walls of the piston and cylinder and cylinder head form a work chamber of variable volume. Driven by the crank-link mechanism, the piston makes reciprocating in the cylinder to realize compression of the gas in the cylinder.

2 The main motor of the air compressor operates in full voltage mode after star-delta reduced voltage starting. The specific work flow of the air supply system: when the Start button is pressed, the control system switches on the starting coil and opens the oil cut-off valve. The compressor starts in unloading mode. At this moment, the suction valve is in closed position and the bleed valve is open to release pressure in the oil/air separator. After releasing pressure for n seconds (the time is controlled by the relay), the compressor starts loading operation and the system pressure begins to rise. If the system pressure rises to the upper limit of the pressure switch taking off pressure, the controller makes the suction valve to close, the oil/gas separator bleeds air, and the compressor operates at no load till the system pressure drops to the lower limit of the pressure switch online pressure. Then, the controller opens the suction valve, closes the bleed valve of the oil/gas separator, and the compressor to operates at full load. Unloading and loading tends to cause frequent variation of the pressure of the entire air network. In this way it is impossible to maintain constant working pressure and prolong the service life of the compressor. Even in the case that low flowrate is needed, with some adjustment methods of air compressor (for example, adjusting with valve, adjusting by unloading, etc.), as the rotational speed of the motor is constant, the reduction of the motor power is relatively low. Energy consumption analysis: Control by loading and unloading makes the pressure of the compressed air varies up and down between P min and P max. P min is the lowest pressure, i.e. the lowest pressure that can ensure normal work of the users. In general cases, the relationship between P min and P max can be expressed with the formula below: P max =(1+δ)P min δ is a percentage and its value is roughly between 15% and 30%. The energy wasted by the compressor in air supply control mode by loading and unloading consists of mainly 2 parts: (1) Electric energy consumed during loading When the pressure reaches the minimum, the original control method decides that the pressure will rise till the maximum. During pressurization, it will certainly dissipate more heat to the outside and thus cause loss of electric energy. On the other hand, the gas of pressure higher than the maximum needs to release pressure through the relief valve before entering the pneumatic elements. This process is also a energy consuming process. (2) Electric energy consumed during unloading When the pressure reaches the maximum, the compressor reduces pressure and unloads in this way: closes the suction valve and allows the motor to operate at no load, meanwhile, vents the redundant compressed air in the separating tank to the atmosphere through the atmos valve. This regulation method results in a large amount of energy waste. By our estimation, the energy consumed by the compressor during unloading accounts for 10% to 25% of that during operating at full load (this is just the case when the unloading time accounts for a low percentage). In other words, the compressor is at no-load state in 20% time and is doing work of no use. It is obvious that in the air supply mode by loading and unloading, there is large energy-saving space for the motor of the compressor. Other shortcomings

3 (1) The suction valve is adjusted with a mechanical method and the air supply volume cannot be adjusted continuously. When the air consumption varies constantly, it is not avoidable that the air supply pressure fluctuates greatly. The accuracy of the supplied air cannot meet the process requirement. Moreover, frequent adjustment of the suction vale can quicken its wearing and increase maintenance works and cost. (2) The bleed valve is opened and closed frequently. The durability of the bleed valve cannot be ensured. 2.2 Frequency conversion operation mode Rotational speed control refers to adjust flowrate by varying the rotational speed of the compressor while keeping the opening of the valve unchanged (keeping at maximum opening). When the rotation speed of the compressor varies, the lift characteristic of the air supply system varies with it while the pipe resistance characteristics keeps unchanged. In this control mode, the rotational speed of the compressor motor is changed with frequency conversion speed regulation technology. The air supply flowrate of the compressor changes with the air consumption flowrate and the real balance between supply and demand is reached in this way. It can enable the whole system to get optimal work efficiency while saving energy. The frequency inverter is based on the principle of AC-DC-AC power conversion. It can output an AC voltage with constantly adjustable frequency according to the demands of the controlled object. The rotational speed of the motor is proportional to the frequency of the power supply. So, by outputting an AC voltage with adjustable frequency as the power voltage of the compressor motor, the frequency inverter can conveniently change the rotational speed of the compressor. 2.3 Constant pressure air supply principle Flowrate is the basic controlled object of the air supply system. Air supply flowrate shall meet the air consumption flowrate at all times. In the air supply system, the air pressure in the reservoir pipe can fully reflect the relation between the air supply capacity and air consumption demand: If the air supply flowrate is higher than the air consumption flowrate, the air pressure in the reservoir pipe will rise. If the air supply flowrate is lower than the air consumption flowrate, the air pressure in the reservoir pipe will drop. If the air supply flowrate is equal to the air consumption flowrate, the air pressure in the reservoir pipe will not change. So, keeping constant pressure in the pipe can ensure the air supply capacity at the point just meets the air consumption demand. This is the aim of the constant pressure air supply system. The frequency conversion speed regulation system takes the pipeline pressure as the controlled object. The pressure transducer fitted at the outlet of the reservoir pipe converts the pressure in the accumulator into electrical signal and sends it to the PID regulator inside the controller. It compares the signal with the pressure setting, conducts operation with preset PID control mode according to the difference, and generates a control signal to control the output voltage and inversion frequency of the frequency inverter, and thus regulates the rotational speed of the motor so that the actual pressure is always maintained at the pressure setting. Additionally, after this solution is adopted, the frequency inverter can realize soft starting from stationary to stable speed of the compressor motor. This can avoid high starting current and mechanical shock to the air compressor caused by starting. In normal cases, the air compressor operates at the frequency inverter speed control mode. Once the frequency inverter becomes faulty, production process does not allow stopping of the air compressor. So the system is designed with switching function between power frequency and variable frequency. In this way, when the frequency inverter becomes faulty, the air compressor will still operate normally with the power supply of power frequency directly supplied via the contactor. The whole control process is as the follows:

4 Air consumption demand pipeline pressure difference between pressure setting and feedback value PID output frequency inverter output frequency rotational speed of compressor motor air supply flowrate pipeline pressure tends to be stable. Feedback value Pressure tolerance Setting Fig 2: Pressure and frequency PID curves Special attention should be paid that, within the pressure tolerance range, the PID of the controller is not adjusted, i.e. the output frequency is kept unchanged. 3. Solution configuration Hereunder we take the application of CHE G/090P-4 in alteration of the compressor of a company in Shanghai as an example. According to the experience in other previous projects, attention should be paid to the following during frequency conversion alteration of air compressors: 1) Air compressor is a load of high moment of inertia. The starting feature is very likely to cause over-current protection of the frequency inverter in V/F control mode during starting. So the vector frequency inverter with high starting torque and without speed sensor (CHE100 series) is recommended to ensure continuity of constant pressure air supply as well as reliable, stable operation of the equipment. 2) Air compressor is not allowed to operate at low frequency for long period. When the rotational speed of an air compressor is too low, on one hand, the operation stability of the compressor will become poor, and on the other hand, the cylinder lubrication will also become poor and this will quicken the wearing. Therefore, the lower limit of the operation frequency should not be lower than 20Hz. 3) In order to effectively filter the high-order harmonic components in the output current of the frequency inverter and reduce the electromagnetic interference caused by the high-order harmonics, output AC reactor is recommended. It can also reduce operation noise and temperature rise of the motor and improve the motor stability. The power of the compressor motor in this air compressor system is 55kW. The power frequency/variable frequency compatible special controller drive solution is designed for the system according to the operating conditions on the field. CHE100 series vector frequency inverter of high starting torque is selected. The specific model is CHE G/090P-4. The fan is driven by a CHF100 general frequency inverter. This solution is suitable for applications with high requirements for accuracy and reliability of the control system. Power frequency/variable frequency compatible double redundant circuits are adopted for the

5 main motor and the fan of the main motor. They operate at variable frequency in normal operating mode and are switched to power frequency when being overhauled or when the frequency conversion circuit becomes faulty. The control mode also changes at the same time.

6 The special controller has many kinds of built-in control logics. It can drive different combinations of switch state. The user can select switch combinations according to the demand to drive different control modes. Additionally, the control logics have been pre-configured and can be changed with one keying. (1) Variable frequency driving of the main motor: the PID operation regulation part of the controller samples the feedback signal from the pressure transducer, performs PID operation with the pressure setting, and outputs the regulation signal to regulate the output frequency of the main frequency inverter. After being switched to power frequency mode, the controller will adjust the discharge pressure by opening or closing the suction valve. (2) Driving of the fan is also selectable between variable frequency and power frequency If the fan adopts variable frequency control mode, the controller samples the feedback signal of the head temperature sensor, performs PID operation with the temperature setting, and outputs the regulation signal to regulate the output frequency of the fan frequency inverter and thus to continuously adjust the fan speed in stepless mode. In this way the temperature of the compressor head is accurately maintained at the set temperature point so that the lubricant of the compressor is kept in optimal effect. If the fan is set in switch control mode, the controller determines the corresponding switch state according to the sampled exhaust temperature to start or stop the fan motor and thus maintains the exhaust temperature within the set temperature range.

7 Main motor of the compressor Fan Y- starting 1. KM5 ON, Y starting 2. KM4 ON, starting 3. KM4 and KM5 shall be interlocked 4. When the main motor is set to direct starting at power frequency, KM4, KM5 and related circuits can be eliminated. 1. The main motor of the compressor can be switched between power frequency and variable frequency: (1) Variable frequency: KM1 & KM3 ON, KM2 OFF and KM5 ON (2) Power frequency: KM2 ON, KM5 ON, Y starting KM2 ON, KM4 ON, starting The sequence of power frequency starting: Y starting, and after certain delay, starting, starting completed, after a delay, open the suction valve, the compressor starts operating. (3) KM2 and KM3 are interlocked. KM4 and KM5 are interlocked. 2. The compressor fan can be switched between power frequency and variable frequency: (1) Variable frequency: KM6 & KM7 ON, KM8 OFF, operates at variable frequency (2) Power frequency: KM8 ON, KM6 & KM7 OFF, operates at power frequency 3. The controller interacts with the two frequency inverters directly with communication. The state of all contactors is determined by the special controller. 4. General description of the special controller The special compressor controller is specifically developed for compressor application. It has many flexible control modes. It can monitor and control many kinds of compressor operation data in real time, provide protection and early-warning functions as well as maintenance reminding functions. The terminal functions are defined as follows: Symbols Definitions Remarks PT1+,PT1- Input of the main motor temperature sensor Detect main motor temperature in real time and use it as the PID regulation signal of the fan and provide feedback data for main motor temperature protection

8 I1+ I2+ Symbols Definitions Remarks V3+,V34- V4+,V34- Input of R-phase current sensor of the main motor Input of T-phase current sensor of the main motor Input of ST-phase voltage sensor Input of pressure transducer I1 shall be shorted with V1+, a phase current transformer is fitted on the input side. I2 shall be shorted with V2+, a phase current transformer is fitted on the input side. A voltage transformer is fitted on the input side. Pressure PID regulation input of the main motor P24V 24V auxiliary power supply X0 Input of the pressure switch X1 Air filter signal input X2 Oil filter signal input X3 Aerosol separator signal input X4 E-stop signal NC COM Common terminal Y0 Y1 Y2 Y3 Y4 Y5 Y6 KM1 KM2 KM3 KM4 KM5 KM6 KM7 COM0 Common terminal 0 Common terminals for Y0~Y1 COM1 Common terminal 1 Common terminals for Y2~Y4 COM2 Common terminal 2 Common terminals for Y5~Y7 RS485 (+ \-) 485 wiring terminal RS485 terminal for communication, supports Modbus communication protocol The compressor controller is designed according to the control process requirement of the rotary screw compressor with LCD display and intuitive, easy UI in both Chinese and English to realize various functions needed by the rotary screw compressor:

9 AC power voltage and phase sequence detection function to avoid reversed rotation of the motor, can be set with under-voltage protection function; PID constant pressure control, the output pressure is stable; With many built-in combination control solutions of variable frequency driving and power frequency driving, the user can set according to field demand if frequency conversion or switching between power frequency and variable frequency is used. The driving mode can be switched with the external setting switch. In this way the operation reliability of the air compressor system is improved. Early-warning and stop protection functions at over-temperature. Over (air) pressure protection ensures safety of air pipeline equipment of the user. Light load starting, smart control of stop after heat dissipation, immediately switch off all control outputs at emergency stop; Temperature and pressure sensors failure detection, immediately protection and warning. Can detect and display the operation current of the main motor and the fan, and can separately set motor overload and phase broken protection; Can detect many types of blockage signals and give early warning. Trouble conditions State display Compressor state Air filter is blocked Air filter is blocked Alarm but not stop Using time of the air filter is out Remained using time of the air filter Alarm but not stop Oil filter is blocked Oil filter is blocked Alarm but not stop Using time of the oil filter is out Remained using time of the oil filter Alarm but not stop Aerosol separator is blocked Aerosol separator is blocked Alarm but not stop Using time of the aerosol separator is out Remained using time of the aerosol separator Alarm but not stop Using time of the lubrication grease is out Motor bearing needs grease filling Alarm but not stop Exhaust temperature is higher than the Alarm due to high temperature Alarm but not stop alarm value exhaust Exhaust temperature is higher than the Stop due to high temperature Alarm and stop stop value exhaust The exhaust temperature is lower than Too low temperature Alarm and stop the limit Exhaust pressure is higher than the limit Stop due to too high pressure Alarm and stop Broken wire of temperature sensor Broken wire of temperature sensor Alarm and stop Broken wire of pressure transducer Broken wire of pressure transducer Alarm and stop Overload of motor The main motor has stopped due to overload Alarm and stop Will delay when starting Overload of fan The fan has stopped due to Alarm and stop overload Wrong phase sequence, lack of phase Stopped due to wrong sequence Alarm and stop Two kinds of interlock control modes are provided to control sequential starting and unloading of the unit. The alternation time is adjustable. The display interface has a simple structure and is easy to understand. The menu is displayed in several levels. The operation is simple and needs no special understanding or remembering; By providing background software for background monitoring, remote monitoring from upper PCs can be realized; Automatic sleep function in the condition of low air consumption can save energy and reduce equipment wearing;

10 Built-in Chinese/English bilingual display, can be switched online; Visual view of operation parameters and states of the air compressor; Real-time perpetual calendar; Can remind various maintenances 100 hours before the planned time according to various maintenance plans; Failure logging can be inquired and is tagged with time mark; Seamless connection with CHE frequency inverter is provided. There is no need to set the function parameters of the frequency inverter; Protected with several levels of passwords, parameters are set on different levels of screens to avoid unauthorized operation, and a spare universal password is provided. Conclusion After the frequency conversion alteration, the air compressor system operates stably and the overall energy-savings rate of the system is 31.8%. In a word, as a high, new technology, basic technology and energy-saving technology, frequency conversion speed regulation technology has been used in various technical departments of all industries. Various problems may occur during application in the air compressor industry, which are waiting for us to solve. We can promote the application of frequency conversion speed regulation technology in air compressor equipment only by fully considering the actual operating conditions and demands and continuously optimizing the solutions. References (1) Shenzhen INVT Electric Co., Ltd. Second Volume of INVT Application Cases. [M], 2009 (2) Shenzhen INVT Electric Co., Ltd. Operation Manual of CHE100 Vector Frequency Inverter. [M], 2009

Air Compressor Control System for Energy Saving in Manufacturing Plant

Air Compressor Control System for Energy Saving in Manufacturing Plant IJSTE - International Journal of Science Technology & Engineering Volume 1 Issue 2 August 2014 ISSN(online) : 2349-784X Air Compressor Control System for Energy Saving in Manufacturing Plant Ms. Snehal

More information

Multiple Pressure Booster Systems With Variable Speed Controller Type BL

Multiple Pressure Booster Systems With Variable Speed Controller Type BL Multiple Pressure Booster Systems With Variable Speed Controller Type BL General Characteristics - Single or multistage pumps - Horizontal or vertical mounting - Total head 30m ~ 250m - Material construction:

More information

Introduction to Pneumatics

Introduction to Pneumatics Introduction to Pneumatics Pneumatics Symbols Air generation and distribution Table 1: Symbols use in energy conversion and preparation ITEM SYMBOL MEANING Compressor SUPPLY Pressure Source Pneumatic Pressure

More information

SF SERIES CNG COMPRESSOR MODEL HF-4MH. 4 Nm3/Hour Displacement OPERATION MANUAL

SF SERIES CNG COMPRESSOR MODEL HF-4MH. 4 Nm3/Hour Displacement OPERATION MANUAL SF SERIES CNG COMPRESSOR MODEL HF-4MH 4 Nm3/Hour Displacement OPERATION MANUAL 1 Content 1. General Description...3 2. Main technical parameters...3 3. Structural principle...4 3.1Main structure...4 3.2Compressor

More information

Project Title: Pneumatic Exercise Machine

Project Title: Pneumatic Exercise Machine EEL 4924 Electrical Engineering Design (Senior Design) Preliminary Design Report 27 January 2011 Project Title: Pneumatic Exercise Machine Team Members: Name: Gino Tozzi Name: Seok Hyun (John) Yun Email:

More information

Introduction. 1. Large oil-free screw compressor, Emeraude ALE series

Introduction. 1. Large oil-free screw compressor, Emeraude ALE series High-performance, energy-saving equipment is much needed to address the growing concern for the environment. To meet such needs, Kobe Steel has developed high-performance, large class, oil-free screw compressors,

More information

Guideline No.M-05(201510) M-05 AIR COMPRESSOR. Issued date: 20 October China Classification Society

Guideline No.M-05(201510) M-05 AIR COMPRESSOR. Issued date: 20 October China Classification Society Guideline No.M-05(201510) M-05 AIR COMPRESSOR Issued date: 20 October 2015 China Classification Society Foreword This Guideline constitutes the CCS rules, and establishes the applicable technical requirements

More information

COMPRESSOR PACK SUCTION CONTROLLER TYPE: LP41x

COMPRESSOR PACK SUCTION CONTROLLER TYPE: LP41x Electrical Installation Requirements Care should be taken to separate the power and signal cables to prevent electrical interference and possible damage due to inadvertent connection. SUPPLY E L N LN2

More information

High Pressure Breathing Air Compressors

High Pressure Breathing Air Compressors High Pressure Breathing Air Compressors [ Full variety for different applications] MSA offers a comprehensive range of high pressure breathing air compressors for both the firefighting and diving market,

More information

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000 Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Automotive and avionics industry Industry (laboratory, workshop and production) Transmitter

More information

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH THIS MANUAL IS INTENDED FOR TECHNICAL STAFF IN CHARGE OF THE INSTALLATION, THE OPERATION AND THE MAINTENANCE OF THIS PRODUCT CAUTION!

More information

Advanced Pump Control for Irrigation Applications

Advanced Pump Control for Irrigation Applications Advanced Pump Control for Irrigation Applications Paul Nistler VFD Applications Engineer And Julian Atchia Director of Research and Development SJE Rhombus 22650 County Hwy 6 Detroit Lakes MN 56502 Executive

More information

Screw Compressors 11-22kW

Screw Compressors 11-22kW INDUSTRIALS GROUP Screw Compressors 11-22kW KSA Plus Fixed Speed, KSV Variable Speed Smart and affordable CHAMPION COMPRESSED AIR TECHNOLOGIES KSA Plus Screw Compressors Up to 45 C ambient temperature

More information

BUBBLER CONTROL SYSTEM

BUBBLER CONTROL SYSTEM BUBBLER CONTROL SYSTEM Description: The HDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air

More information

Constant pressure air charging cascade control system based on fuzzy PID controller. Jun Zhao & Zheng Zhang

Constant pressure air charging cascade control system based on fuzzy PID controller. Jun Zhao & Zheng Zhang International Conference on Applied Science and Engineering Innovation (ASEI 2015) Constant pressure air charging cascade control system based on fuzzy PID controller Jun Zhao & Zheng Zhang College of

More information

Roller AC Servo System

Roller AC Servo System Safely Instruction Roller AC Servo System HMI-15 User Manual Please read this manual carefully, also with related manual for the machinery before use the controller. For installing and operating the controller

More information

A4s Operation Manual

A4s Operation Manual A4s Operation Manual Safety Instruction Please read this manual carefully, also with related manual for the machinery before use the controller. For installing and operating the controller properly and

More information

CCT-7320/ROC-2313 Reverse Osmosis Controller

CCT-7320/ROC-2313 Reverse Osmosis Controller CCT-7320/ROC-2313 Reverse Osmosis Controller 1 General The instrument is a combined control instrument of a reverse osmosis controller and an on-line conductivity instrument. It can perform the operation

More information

Research of Variable Volume and Gas Injection DC Inverter Air Conditioning Compressor

Research of Variable Volume and Gas Injection DC Inverter Air Conditioning Compressor Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2016 Research of Variable Volume and Gas Inection DC Inverter Air Conditioning Compressor

More information

Unit 24: Applications of Pneumatics and Hydraulics

Unit 24: Applications of Pneumatics and Hydraulics Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 9 ACCUMULATORS The material needed for outcome 2 is very extensive so there are

More information

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL OTHER FLUID POWER VALVES. This work covers part of outcome 2 of the Edexcel standard module:

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL OTHER FLUID POWER VALVES. This work covers part of outcome 2 of the Edexcel standard module: FLUID POWER FLUID POWER EQUIPMENT TUTORIAL OTHER FLUID POWER VALVES This work covers part of outcome 2 of the Edexcel standard module: UNIT 21746P APPLIED PNEUMATICS AND HYDRAULICS The material needed

More information

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times Tseries Series AB AB Air Air Boosters Boosters The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times.01/1 MANIFOLD MOUNTED VALVES FOR EASY SERVICING

More information

The Ins and Outs of I/P Transducers

The Ins and Outs of I/P Transducers The Ins and Outs of I/P Transducers By Mark B. Levine, ControlAir Inc. General description I/P transducers are versatile instruments that use an electrical control signal to proportionally regulate gas

More information

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter Overview C % ppm 4~20mA Analog Output ppb Power Supply 100~240 VAC mg/l Dimensions 96 x 96 x 132mm RS-485 Digital Output (for DC-5310-RS only)

More information

ASERCOM guidelines for the design of multiple compressor racks using frequency inverters

ASERCOM guidelines for the design of multiple compressor racks using frequency inverters ASERCOM guidelines for the design of multiple compressor racks using frequency inverters Contents 1 SCOPE AND PURPOSE 2 SELECTION OF COMPRESSORS 3 DESIGN FEATURES 4 CONTROL FEATURES 5 STABILITY OF WORKING

More information

Compressors. Basic Classification and design overview

Compressors. Basic Classification and design overview Compressors Basic Classification and design overview What are compressors? Compressors are mechanical devices that compresses gases. It is widely used in industries and has various applications How they

More information

Control & Maintenance. INT69 Diagnose INT69 TM Diagnose. Protect the heart of your system

Control & Maintenance. INT69 Diagnose INT69 TM Diagnose. Protect the heart of your system Control & Maintenance INT69 Diagnose INT69 TM Diagnose Protect the heart of your system R INT69 DIAGNOSE The widely known protective system INT69 and INT69 TM present on all Frascold compressors is now

More information

RS D RSF D with direct drive

RS D RSF D with direct drive Screw compressors RS 2-75 109 D RSF 87 127 D with direct drive Made in Germany Motor power: 75 127 kw RENNER GmbH Kompressoren success rooted in tradition. RENNER GmbH Kompressoren have been known for

More information

WF STEUERUNGSTECHNIK GMBH. INFORMATION and TECNICAL DESCRIPTION

WF STEUERUNGSTECHNIK GMBH. INFORMATION and TECNICAL DESCRIPTION 1 INFORMATION and TECNICAL DESCRIPTION 14 2 AIRLEADER Professional Compressor Management + Compressed Air Visualisation + Alarm Service Management + AIRLEADER - has been the effective answer for compressed

More information

CHAPTER 3 : AIR COMPRESSOR

CHAPTER 3 : AIR COMPRESSOR CHAPTER 3 : AIR COMPRESSOR Robotic & Automation Department FACULTY OF MANUFACTURING ENGINEERING, UTeM Learning Objectives Identify types of compressors available Calculate air capacity rating of compressor

More information

Exercise 4-2. Centrifugal Pumps EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Pumps

Exercise 4-2. Centrifugal Pumps EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Pumps Exercise 4-2 Centrifugal Pumps EXERCISE OBJECTIVE Familiarize yourself with the basics of liquid pumps, specifically with the basics of centrifugal pumps. DISCUSSION OUTLINE The Discussion of this exercise

More information

V-Major, V-Compact. Reciprocating Compressors. Intelligent Air Technology

V-Major, V-Compact. Reciprocating Compressors. Intelligent Air Technology V-Major, V-Compact Reciprocating Compressors Intelligent Air Technology & Significant Energy Savings with Lower Running Costs Efficient. LOW POWER CONSUMPTION 75% of the running cost of an air compressor

More information

A4 Operation Manual. Fig.1-1 Controller Socket Diagram

A4 Operation Manual. Fig.1-1 Controller Socket Diagram A4 Operation Manual Safety Instruction Please read this manual carefully, also with related manual for the machinery before use the controller. For installing and operating the controller properly and

More information

Part 1 General Information Part 2 Outdoor Units... 8

Part 1 General Information Part 2 Outdoor Units... 8 Contents Part 1 General Information... 1 Part 2 Outdoor Units... 8 Part 3 Installation... 71 Part 4 Part 5 Trouble shooting 99 Control system. 126 Manufacture reserves the right to discontinue, or change

More information

International Research Journal of Electronics and Computer Engineering Vol 1(3) Oct-Dec 2015

International Research Journal of Electronics and Computer Engineering Vol 1(3) Oct-Dec 2015 The PLC Based Design for the Air Compressor Control Process Miss Zahra Haghparas Electrical and electronic engineering Shiraz university of technology Shiraz, Iran f.haghparas@yahoo.com Ebrahim Abiri Associate

More information

EPP4 Pressure Regulator Basic G 1/4"

EPP4 Pressure Regulator Basic G 1/4 EPP4 Pressure Regulator Basic G 1/4" Flow Curve 1/4" Dimensions Outlet pressure - bar 9 8 7 6 5 4 3 2 1 0 0 20 40 60 70 80 100 120 Flow rate - Nm 3 /h The male connector adopted on the EPP4 is a standard

More information

AHE58/59 AC Servo System

AHE58/59 AC Servo System AHE58/59 AC Servo System HMI-12 User Manual Safely INstruction Please read this manual carefully, also with related manual for the machine head before use. For perfect operation and safety, installing

More information

Description. Chassis. Cabinet. Long chassis - Type: Dimensions (mm): 2700 x 1200 x 1678

Description. Chassis. Cabinet. Long chassis - Type: Dimensions (mm): 2700 x 1200 x 1678 1 ITV bench is equipped with a INJETVISION vision system whose purpose is to observe and study the jets from high pressure diesel injector in inert atmosphere (nitrogen or CO2) up to 50 bar (± 0.5 bar).

More information

Visualize Nitrogen Gas Consumption

Visualize Nitrogen Gas Consumption Air Flow Monitor EWA2 SERIES Conforming to EMC Directive (all models) & Pressure Equipment Directive (AEWA2150/2200 only) Visualize Nitrogen Gas Consumption Small pipe size as Well as Air Consumption!

More information

Optimization of Air compressor Motor speed for Reducing Power Consumption

Optimization of Air compressor Motor speed for Reducing Power Consumption Optimization of Air compressor Motor speed for Reducing Power Consumption Amit Bahekar 1, Dr. Sanjeev Yadav 2 1 Research Scholar, Department of Mechanical Engineering, Sunrise University, Alwar(Raj). 2

More information

MECHANICAL EQUIPMENTS: COMPRESSORS, PUMPS, SEALS, SPEED DRIVES, CONTROL VALVES & ACTUATORS & SAFETY RELIEF VALVES

MECHANICAL EQUIPMENTS: COMPRESSORS, PUMPS, SEALS, SPEED DRIVES, CONTROL VALVES & ACTUATORS & SAFETY RELIEF VALVES Training Title MECHANICAL EQUIPMENTS: COMPRESSORS, PUMPS, SEALS, SPEED DRIVES, CONTROL VALVES & ACTUATORS & SAFETY RELIEF VALVES Training Duration 5 days Training Venue and Dates REF Mechanical Equipments:

More information

KIT. Small Automatic Water Boosters KIT MODELS

KIT. Small Automatic Water Boosters KIT MODELS KIT Small Automatic Water Boosters The electronic controller KIT orders the automatic start and stop of the water pump when opening or closing any tap or valve in the installation. There are four main

More information

Aquavar SOLO 2 Frequently Asked Questions

Aquavar SOLO 2 Frequently Asked Questions Aquavar SOLO 2 Frequently Asked Questions How do I size the Aquavar SOLO 2 for the appropriate pump/motor combination? Can I use a 208 Volt motor? Can I run the Aquavar SOLO 2 up to 80HZ? What are the

More information

Design Envelope Booster. Sequence of operation

Design Envelope Booster. Sequence of operation Design Envelope Booster Sequence of operation File No: 62.835 Date: february 11, 2015 Supersedes: 62.835 Date: july 11, 2014 sequence of operation Design Envelope Booster 2 general The packaged domestic

More information

RS 2-75 D 109 D RSF 87 D 127 D with direct drive

RS 2-75 D 109 D RSF 87 D 127 D with direct drive Screw compressors RS 2-75 D 109 D RSF 87 D 127 D with direct drive Made in Germany Motor size: 75 127 kw RENNER GmbH Kompressoren Success Rooted in Tradition. RENNER GmbH Kompressoren have been known for

More information

A Fault Diagnosis Monitoring System of Reciprocating Pump

A Fault Diagnosis Monitoring System of Reciprocating Pump IOSR Journal of Engineering (IOSRJEN) ISSN (e): 2250-3021, ISSN (p): 2278-8719 Vol. 05, Issue 09 (September. 2015), V1 PP 01-06 www.iosrjen.org A Fault Diagnosis Monitoring System of Reciprocating Pump

More information

TABLE OF CONTENTS 2 TALAS DRYER 4 TALAS MEASURER 7 TALAS PORTABLE DRYER 9 TALAS LEAKER 11 TALAS STARTER 14 TALAS AUXILIARY 17 APPENDICES

TABLE OF CONTENTS 2 TALAS DRYER 4 TALAS MEASURER 7 TALAS PORTABLE DRYER 9 TALAS LEAKER 11 TALAS STARTER 14 TALAS AUXILIARY 17 APPENDICES TABLE OF CONTENTS 2 TALAS DRYER 4 TALAS MEASURER 7 TALAS PORTABLE DRYER 9 TALAS LEAKER 11 TALAS STARTER 14 TALAS AUXILIARY 17 APPENDICES ALL PICTURES SHOWN ARE FOR REFERENCE ONLY ACTUAL PRODUCT MAY VARY

More information

Puyuan. QUY 160 Crawler Crane Technical Manual

Puyuan. QUY 160 Crawler Crane Technical Manual Puyuan QUY 160 Crawler Crane Technical Manual 5 Pictures and technical parameters in sample books may not accord with the delivery goods because of the improvement in design. Please understand and make

More information

Vibration and Pulsation Analysis and Solutions

Vibration and Pulsation Analysis and Solutions 1 Vibration and Pulsation Analysis and Solutions Brian Howes, M.Sc., P.Eng. Beta Machinery Analysis Ltd. Problems created by excessive vibration in machinery can have serious economic impact. Frequently

More information

QGV Series. Quincy QGV Series. Rotary Screw Air Compressors hp

QGV Series. Quincy QGV Series. Rotary Screw Air Compressors hp QGV Series Quincy QGV Series Rotary Screw Air Compressors 75-200 hp Quality Comes in All Shapes and Sizes But Just One Color. True Life Cycle Cost = Purchase Price + Energy Costs + Parts and Service +

More information

Simplicity in VRU by using a Beam Gas Compressor

Simplicity in VRU by using a Beam Gas Compressor Simplicity in VRU by using a Beam Gas Compressor By Charlie D. McCoy and Mark Lancaster Abstract: Vapor Recovery Units are often expensive, complicated to operate and unable to deal with High H2S and liquids.

More information

V10K GAS FEED SYSTEM WALLACE & TIERNAN PRODUCTS

V10K GAS FEED SYSTEM WALLACE & TIERNAN PRODUCTS V10K GAS FEED SYSTEM WALLACE & TIERNAN PRODUCTS V10K SYSTEM: PROVEN TECHNOLOGY WORLDWIDE IN USE Since Charles F. Wallace and Martin F. Tiernan discovered the first chlorine gas feed system in 1913 the

More information

The Discussion of this exercise covers the following points: Pumps Basic operation of a liquid pump Types of liquid pumps The centrifugal pump.

The Discussion of this exercise covers the following points: Pumps Basic operation of a liquid pump Types of liquid pumps The centrifugal pump. Exercise 2-3 Centrifugal Pumps EXERCISE OBJECTIVE In this exercise, you will become familiar with the operation of a centrifugal pump and read its performance chart. You will also observe the effect that

More information

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1. 2 GALLON TWIN STACK AIR COMPRESSOR Model: 9526 DO NOT RETURN TO STORE. Please CALL 800-348-5004 for parts and service. CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or

More information

11 Air ends 12 Motor 13 Belt driven. 1. ELECTRONIC REGULATION The ES4000 is a control system, designed for medium and high power compressors.

11 Air ends 12 Motor 13 Belt driven. 1. ELECTRONIC REGULATION The ES4000 is a control system, designed for medium and high power compressors. Infinity CSC & CSD Rotary Screw Compressor Range Infinity CSC/CSD compressors are a compact, easy to install range, offering belt or gear driven, fixed or variable speed models. Requiring minimal maintenance,

More information

HANDBOOK. Squeeze Off Unit SOU 400. Please refer any queries to:

HANDBOOK. Squeeze Off Unit SOU 400. Please refer any queries to: HANDBOOK Squeeze Off Unit SOU 400 Please refer any queries to: Hy Ram Engineering Co Ltd Pelham Street Mansfield Nottinghamshire NG18 2EY Telephone No: (01623) 422982 Please note all queries should state

More information

New Energy-saving Air Compressors

New Energy-saving Air Compressors FEATURED ARTICLES Environmentally Conscious Technology in Industrial Fields Aiming for a Low-carbon Society New Energy-saving Air Compressors Air compressors produce compressed air and have a wide variety

More information

Automatic Valve Proving Control

Automatic Valve Proving Control ISO 9001 Automatic Valve Proving Control 7 696 LDU11 UL recognized FM approved Features Performs leak test of the gas shut-off valves before start-up and/or immediately after burner shut-down No inlet

More information

AUTOMATIC GAS MANIFOLDS

AUTOMATIC GAS MANIFOLDS AUTOMATIC GAS MANIFOLDS Phoenix Pipeline Products Limited. Unit 8, McKenzie Industrial Park, Tel No.: 44 (0) 161 428 7200 Bird Hall Lane, Fax No.: 44 (0) 161 428 7010 Stockport, Email: info@p3-phoenix.com

More information

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Models: EPS Single Pump EPT Twin Pump EPS-HP EPT-HP Single Pump High Pressure Twin Pump High Pressure

More information

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly. Components preparation and pressure adjustment ABP Overview ABP is a component that enables boosting by s only up to twice primary pressure (.0MPa max.) in combination with using air tank but not using

More information

ACV-10 Automatic Control Valve

ACV-10 Automatic Control Valve ACV-10 Automatic Control Valve Installation, Operation & Maintenance General: The Archer Instruments ACV-10 is a precision automatic feed rate control valve for use in vacuum systems feeding Chlorine,

More information

APPLICATION NOTES DELOMATIC 4, DM-4 GAS

APPLICATION NOTES DELOMATIC 4, DM-4 GAS APPLICATION NOTES DELOMATIC 4, DM-4 GAS Emission control Lambda sensor p/t regulation Combustion chamber temperature regulation Emission control configuration Emission control curve Document no.: 4189340653C

More information

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc. The HumiSys RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The new HumiSys with single or dual RH probes capabilities is

More information

The Control of an Oil Injected Screw Compressor Package Deployed in a Naphtha Cracking Process

The Control of an Oil Injected Screw Compressor Package Deployed in a Naphtha Cracking Process The Control of an Oil Injected Screw Compressor Package Deployed in a Naphtha Cracking Process Dr. W.J. MILLIGAN, Howden Process Compressors Ltd, Renfrew, UK Prof. D.K. HARRISON, Glasgow Caledonian University,

More information

Controller for boilers Galan - regulator for management of heating elements and circuit SolarSentinel-DBTW User guide

Controller for boilers Galan - regulator for management of heating elements and circuit SolarSentinel-DBTW User guide Controller for boilers Galan - regulator for management of heating elements and circuit SolarSentinel-DBTW User guide SHORT DESCRIPTION: 1. Device is applicable to: Burners, Electric boiler, Electric heaters,

More information

The Criticality of Cooling

The Criticality of Cooling Reliability Solutions White Paper January 2016 The Criticality of Cooling Utilities, power plants, and manufacturing facilities all make use of cooling towers for critical heat transfer needs. By cycling

More information

Development of Large Capacity CO2 Scroll Compressor

Development of Large Capacity CO2 Scroll Compressor Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2008 Development of Large Capacity CO2 Scroll Compressor Kenji Yano Mitsubishi Electric

More information

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1 Dry 131h 1. DESCRIPTION The Viking Model G-1 Maintenance Air Compressor is an electric motor-driven, aircooled, single-stage, oil-less compressor. The unit is equipped with a check valve and provides a

More information

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST OIL-LESS TYPE IMPORTANT: PLEASE READ CAREFULLY BEFORE STARTING OPERATIONS. THE CONTENTS ARE FOR GENERAL INFORMATION OF ALL THE SIMILAR MODELS. Record

More information

Let s examine the evolution and application of some of the more popular types. Cascading Pressure Type

Let s examine the evolution and application of some of the more popular types. Cascading Pressure Type Your facility personnel typically know when not enough air compressors are operating. The demand side system air pressure drops below what is required for production triggering phone calls and complaints.

More information

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000 Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Healthcare and avionics industry Industry (laboratory, workshop and production) Transmitter

More information

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module: FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS This work covers part of outcome 2 of the Edexcel standard module: UNIT 21746P APPLIED PNEUMATICS AND HYDRAULICS The material needed for outcome

More information

SINGLE VALVE WITH LOW-FLOW BYPASS

SINGLE VALVE WITH LOW-FLOW BYPASS CONTROL VALVES Pressure Reducing Valve Sizing Guide Sizing pilot operated reducing valves is not a complicated process. It starts with determining requirements and following these guidelines in valve size

More information

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION OCT2010 STOKVIS ENERGY SYSTEMS 96R WALTON ROAD EAST MOLESEY SURREY KT8 0DL TEL: 020 87833050

More information

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications Application Description AG/266PILD-EN Rev. C 2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic Pressure Measurement Engineered solutions for all applications Increase plant productivity

More information

A TECHNICAL REFERENCE

A TECHNICAL REFERENCE A TECHNICAL REFERENCE FOR CAREL DCM CONTROLLERS DIGITAL COMPRESSOR MODULE CANADIAN HEAD OFFICE AND FACTORY USA HEAD OFFICE AND FACTORY CANADIAN EASTERN FACTORY 1401 HASTINGS CRES. SE CALGARY, ALBERTA T2G

More information

PEAPOD. Pneumatically Energized Auto-throttled Pump Operated for a Developmental Upperstage. Test Readiness Review

PEAPOD. Pneumatically Energized Auto-throttled Pump Operated for a Developmental Upperstage. Test Readiness Review PEAPOD Pneumatically Energized Auto-throttled Pump Operated for a Developmental Upperstage Test Readiness Review Customer: Special Aerospace Services Chris Webber and Tim Bulk 1 Overview Project Overview

More information

Net$ync II. Net$ync II. System Controllers

Net$ync II. Net$ync II. System Controllers Net$ync II Net$ync II System Controllers Net$ync II Conductor System System Optimization The Quincy Net$ync II Conductor system selects the most efficient combination of compressors based on demand. Consistent,

More information

Squeegee Unit for MRS Multi-Recovery System

Squeegee Unit for MRS Multi-Recovery System En Operating Instructions Squeegee Unit for MRS Multi-Recovery System Translation of the original operating instructions Squeegee - MRS Table of Contents Safety Recommendations Technical Data - MRS Booth

More information

Basic Pneumatics. Module 8: Pressure control valves. Academic Services PREPARED BY. April 2012

Basic Pneumatics. Module 8: Pressure control valves. Academic Services PREPARED BY. April 2012 Basic Pneumatics Module 8: Pressure control valves PREPARED BY Academic Services April 2012 Applied Technology High Schools, 2012 Module 8: Pressure control valves Module Objectives After the completion

More information

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO 97C COMPRESSOR KIT 12V PART NO. 00097 97C COMPRESSOR KIT 24V PART NO. 02497 98C COMPRESSOR KIT PART NO. 00098 97C 98C IMPORTANT: It is essential that you and any other operator of this product read and

More information

4-7 kw/ hp. Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward

4-7 kw/ hp. Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward GN 4-7 kw/5.5-10 hp Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward Total capability, total responsibility Right at the heart of your business, Atlas Copco delivers quality compressed air

More information

VACUUM REGULATORS CONTENTS

VACUUM REGULATORS CONTENTS CAD drawing data catalog is available. ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Small Regulators Features 759 Specifications, Order Codes, Flow Rate

More information

SRL Series. Oil-less Scroll Air Compressors. Pharmaceutical. Research & Development. Food & Beverage. Chemical. Electronic

SRL Series. Oil-less Scroll Air Compressors. Pharmaceutical. Research & Development. Food & Beverage. Chemical. Electronic Pharmaceutical SRL Series Oil-less Scroll Air Compressors Research & Development Food & Beverage Chemical Electronic Hitachi Industrial Equipment Product Brochure Hitachi SRL Series scroll compressors

More information

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor INDUSTRIAL INSTRUMENTS AND CONTROLS SPECIALIST Kent-Taylor 2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters Features Include Base accuracy : ±0.075% Span limits

More information

Oil-Lubricated Compressors for Regenerative Cryocoolers Using an Elastic Membrane

Oil-Lubricated Compressors for Regenerative Cryocoolers Using an Elastic Membrane Oil-Lubricated Compressors for Regenerative Cryocoolers Using an Elastic Membrane E.C. Luo, Z.H. Wu, G.Y. Yu, J.Y. Hu, and W. Dai Technical Institute of Physics and Chemistry Chinese Academy of Sciences

More information

COMPRESSED AIR TEXTILES ENERGY EFFICIENCY

COMPRESSED AIR TEXTILES ENERGY EFFICIENCY TEXTILES ENERGY EFFICIENCY GUIDANCE NOTE 01 COMPRESSED AIR Compressed air often accounts for more than 10% of textile companies annual electricity use. It is referred to as the forgotten utility, as the

More information

HIGH PRESSURE DRILLING FLUID PUMP

HIGH PRESSURE DRILLING FLUID PUMP 1 HDF 200/250-280 HIGH PRESSURE DRILLING FLUID PUMP Dynaset HDF pump gives great water power with small amount of water in relation to its size. As self-priming it is productive in hard environment. Small

More information

200 PSI HIGH-FLOW AIR SOURCE KIT

200 PSI HIGH-FLOW AIR SOURCE KIT 200 PSI HIGH-FLOW AIR SOURCE KIT 50% Duty Compressor on 2.0 Gallon Air Tank PART NO. 20008 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of

More information

Acoustical Modeling of Reciprocating Compressors With Stepless Valve Unloaders

Acoustical Modeling of Reciprocating Compressors With Stepless Valve Unloaders Acoustical Modeling of Reciprocating Compressors With Stepless Valve Unloaders Kelly Eberle, P.Eng. Principal Engineer keberle@betamachinery.com Brian C. Howes, M.Sc., P.Eng. Chief Engineer bhowes@betamachinery.com

More information

MONSOON 6V Pump Control System

MONSOON 6V Pump Control System MONSOON 6V Pump Control System Installation and Operating Instructions Please pass these instructions on to the operator of this equipment. INTRODUCTION MONSOON 6V Pump Controller The MONSOON 6V pump control

More information

BUBBLER CONTROL SYSTEM

BUBBLER CONTROL SYSTEM BUBBLER CONTROL SYSTEM Description: The LDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air

More information

Tradition & Technology

Tradition & Technology Gaterotor Support Gaterotor Single Screw Compressors Design & Operation Bearing Bearings Main Screw Parallex Slide System The VSM Single Screw Compressor has one main rotor and two gaterotors. All bearings

More information

User s manual VCI07. For variable speed compressors ed00. Applicable as of Version 12. Bar PSI C F

User s manual VCI07. For variable speed compressors ed00. Applicable as of Version 12. Bar PSI C F User s manual EN VCI07 For variable speed compressors 62 205 930 11 ed00 Applicable as of Version 12 Bar PSI C F Table of contains 1 - GENERAL INFORMATION...3 2 - USER INTERFACE...3 2.1 DISPLAYS...3 2.2

More information

Nirvana Variable-Speed Drive, Contact-Cooled Rotary Screw Air Compressors

Nirvana Variable-Speed Drive, Contact-Cooled Rotary Screw Air Compressors Variable-Speed Drive, Contact-Cooled Rotary Screw Air Compressors Exceptional Reliability Introducing - A True Variable-Speed Drive Compressor Now Available in Single- and Two-Stage. By matching a standard

More information

LENNOX SLP98UHV DIAGNOSTIC CODES

LENNOX SLP98UHV DIAGNOSTIC CODES Code Status of Equipment Action required to clear and recover - Idle mode (Decimal blinks at 1 Hertz -- 0.5 second ON, 0.5 second OFF) A Cubic feet per minute (cfm) setting for indoor blower (1 second

More information

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars. Simply a question of better measurement SCHMIDT Flow Sensor SS 20.261 The cost-effective alternative in pressurised systems up to 10 bars. Compressed air technology Industrial processes A cost analysis

More information

USER S MANUAL BASIC HORIZONTAL OIL-LUBRICATED MICROCOMPRESSOR Reference: RCMPBH

USER S MANUAL BASIC HORIZONTAL OIL-LUBRICATED MICROCOMPRESSOR Reference: RCMPBH USER S MANUAL BASIC HORIZONTAL OIL-LUBRICATED MICROCOMPRESSOR Reference: RCMPBH THIS MANUAL IS INTENDED FOR TECHNICAL STAFF IN CHARGE OF THE INSTALLATION, THE OPERATION AND THE MAINTENANCE OF THIS PRODUCT

More information

MICRO DIAPHRAGM GAS PUMPS

MICRO DIAPHRAGM GAS PUMPS MICRO DIAPHRAGM GAS PUMPS DATA SHEET E 5 NMP83KNE NMP85KPDC NMP85.1.2KPDC-B Concept The micro diaphragm gas pumps from KNF are based on a simple principle an elastic diaphragm, fixed on its edge, moves

More information