Standard Specifications. Fluid Proof pressure Maximum operating pressure. Regulating pressure range

Size: px
Start display at page:

Download "Standard Specifications. Fluid Proof pressure Maximum operating pressure. Regulating pressure range"

Transcription

1 Manifold Regulator Series ARM000/000 connection methods Standard Specifications Fluid Proof pressure Maximum operating pressure Regulating pressure range Ambient and fluid temperature Fluid Cracking pressure (Valve) Construction Air. MPa 0. MPa 0.0 to 0. MPa 0. MPa setting 0.0 to 0. MPa to 0 C (No freezing) Air 0.0 MPa Relieving type Small size pressure gauge ø Backflow function available on the standard model Space-saving ARM000-B JIS Common ARM000-A-0 ARM000-A-0 Individual Port Size/Weight Model ARM000 ARM000 ARM 000 Regulator for manifold Body size Piping Common Individual Common Individual Number of stations station 0 0 stations Piping A Manifold side Common A Body side B Manifold side Individual B Body side Note ) In the case of A and B, a pressure gauge or a plug is mounted on the body side, while in case of A and B, on the manifold side. Note ) When mounting a pressure gauge on the body side, its front faces the adjusting screw. Option: Pressure auge: -0-0 M x 0. Port size Weight (g) side side Total weight (n: stations) Regulator (Except manifold) (0 x n) + (9 x n) + ( x n) + ( x n) + How to Order A 0 Port size ( side) 0 Thread type Accessory Rc None (With plug) N NPT With pressure gauge Note ) When ordering single unit Description ARM000 ARM000 Regulator main body ARM000A ARM000A Manifold Common - - Individual - - in manifold part no. repersents the number of manifold stations of regulator. Note ) When a regulator is not mounted on the manifold, use the following blank plate ass'y (with mounting screws and O-ring) For ARM000: Part no. A For ARM000: Part no. A How to Order 0 0 Max. display pressure 0.0 MPa Not able to set the pressure excceding.0 MPa. Option 0. MPa setting Note ) Pressure gauge for.0 MPa is used. Note ) Compared with standard specifications, its adjusting spring has only been changed. It is not the product which does not allow the pressure more than 0. MPa. Adjusting spring is not replaceable. 0 Connecting thread / male thread, M female thread -- Precautions When drain or oil, etc. gets into the gauge, an error may occur for pressure indication. N Thread type Rc NPT Note ) Use caution not to tighten excessively when mountinga pressure gauge, otherwise it may result in a breakdown. Tightening torque recommended (M:. to N m, R/: to 9 N m) For sealing, use a pipe tape.

2 Construction (Individual ) Lock nut (Body side) Flow Characteristics Inlet pressure: 0. MPa Outlet pressure (MPa) F.R.L. AV AU Flow rate (l/min (ANR)) AF AR Component Parts No. q w e r t y No. u i o!0! Description Body Manifold Valve guide Piston Adjusting spring Adjusting screw Replacement Parts Setting Description Valve Valve spring Valve guide O-ring O-ring Material Brass, HNBR Stainless steel Polyacetal NBR NBR. Make sure to check the inlet pressure before setting the outlet pressure. Turning the pressure adjustment handle clockwise increases the outlet pressure and turing it counterclockwise decreases Material Aluminum die-casted Aluminum alloy Brass Brass Steel wire Steel (Manifold side) Part no. ARM x. x. JIS B 0P Note Chromate treated Chromate treated Zinc chromated Electroless nickel plated ARM000-0 x 0 x. JIS B 0P the pressure. (To set the pressure, do so in the direction of pressure increase.). Set the outlet pressure to % or less of the inlet pressure. Precautions Outlet pressure (MPa) Outlet pressure (MPa) Flow rate (l/min (ANR)) Pressure Characteristics (Initial setting) Inlet pressure: 0. MPa Outlet pressure: 0. MPa Flow rate: 0 l/min (ANR) Initial set point IR VEX AMR ITV IC VBA VE VY PPA AL Be sure to read before handling. Refer to pages -- to -- for Safety Instructions and Common Precautions. Mounting/Adjustment. In the case of the common style, supply pressure from the two ports from both ends. Failure to observe this procedure could result in an excessive pressure drop.. Release the lock to adjust the pressure. After the adjustment, engage the lock. Failure to observe this procedure could damage the handle or cause the outlet pressure to fluctuate. <Lock operating method> Loosen the lock nut to unlock it, and tighten it to lock it.. This product can be used as a regulator with a check valve by installing it between solenoid valve and actuator. Maintenance. Make sure to perform a periodic inspection of the pressure gauge when it is used by installing it between solenoid valve and actuator, etc. Sudden pressure changes could happen and the durability of the product could be reduced. Using an electronic style pressure gauge is recommended, depending on the situation. Outlet pressure (MPa) Inlet pressure (MPa) Inlet pressure (MPa) Initial set point --

3 Dimensions. (With pressure gauge) (Mounting hole) Pressure gauge (Option) (With pressure gauge) Pressure gauge (Option) (Common, with plug) (Individual ) (Common ) (Pitch) Dimensions Model ARM000 ARM000 A.. B. C D E F 0 0 H 9. J K 9 M P 9. Q.. R.. Dimensions by the Number of Stations Model ARM000 ARM000 L L L L Manifold stations (n)

4 Manifold Regulator Modular Style Series ARM00/000 A modular type that can be freely mounted on a manifold station. Optimal for central pressure control. Easily set up using the new handle. Also has a Onetouch lock system. ARM000 ARM00 ARM 00 Regulator for manifold Body size Number of stations 0 stations 0 0 stations Standard Specifications How to Order 0 A Proof pressure Maximum operating pressure Regulating pressure range Ambient and fluid temperature Fluid Construction Piping A B 0 Accessory None (With plug) -0-0 A-0-0 Pressure gauges are shipped together (but not assembled). Port size ( side) Port size Applicable model 0 / ARM00 0 / ARM000 Thread type Rc N NPT F Type Common Individual From end plate From port or port. MPa.0 MPa 0.0 to 0. MPa to 0 C (No freezing) Air Relieving type F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY PPA AL JIS Common Individual Port Size/Weight Model Piping Common ARM00 Individual Common ARM000 Individual Port size side Body End plate side Pressure gauge port size Weight (kg) Regulator End plate Weight by the Number of Stations (kg) Stations Model 9 0 ARM ARM

5 Series ARM00/000 Option: Pressure auge (Max. pressure indication:.0 MPa) -0-0 A-0-0 Flow Characteristics ARM00 Inlet pressure: = 0. MPa Width across flats 0 Outlet pressure (MPa) Note ) in the gauge part no. (e.g. -0-0) indicates the type of threads used for connection. For Rc, leave the symbol blank, and for NPT, enter N. Please consult with for the supply of a pressure gauge with NPT port threads. Note ) Use caution not to tighten excessively when mounting a pressure gauge, otherwise it will may result in a breakdown. For sealing, use a pipe tape. Torque recommended: (R /: to N m). Option: Mounting Bolt Assembly Model ARM00 ARM000 Option: Bracket Assembly Individual type can be used as a single unit regulator. Example of mounting Bracket Part no. Dimensions Hexagon socket head cap screw (M x 0) Hexagon socket head cap screw (M x ) Qty. Note With flat washer With flat washer ARM000 Outlet pressure (MPa) Flow rate (l/min (ANR)) Set nut Pressure Characteristics ARM00 Flow rate (l/min (ANR)) Initial setting P = 0. MPa P = 0. MPa Q = 0 l/min (ANR) Model Part no. Composition of assembly A ARM00 Set nut (9) Bracket (B0) 0 ARM000 Set nut () Bracket (B0) Note) Tighten the set nut securely and fix it. Recommended torque for set nut ARM00:. ±. N m ARM000:. ±. N m. Release the lock to adjust the pressure. After the adjustment, engage the lock. Failure to observe this procedure could damage the handle or cause the secondary pressure to fluctuate. ) On the ARM00 type, pull the adjustment handle to release the lock and push the adjustment handle to engage the lock. If it does not lock easily, turn the handle slightly clockwise or counterclockwise before pushing it. ) On the ARM000 type, pull the adjustment handle to release the lock. (An orange colored line is provided at the bottom of the adjustment handle for visual checking.) B 0 C 0. Precautions Mounting/Adjustment D.. E. F.. H M x. M x. Be sure to read before handling. Refer to pages -- to -- for Safety Instructions and Common Precautions. -- Push the adjustment handle to engage the lock. If it does not lock easily, turn the handle slightly clockwise or counterclockwise; then, push it until the orange colored line is no longer visible.. Make sure to check the inlet pressure before setting the pressure. The outlet pressure must be set to % or less of the inlet pressure. Failure to observe this procedure could cause the outlet pressure to fluctuate.. In the case of the common type, supply pressure from the two ports from both ends. Failure to observe this procedure could lead to an excessive pressure drop. Outlet pressure (MPa) ARM000 Outlet pressure (MPa) Inlet pressure (MPa) Inlet pressure (MPa)

6 Manifold Regulator Modular Style Series ARM00/000 Construction F.R.L. AV AU Component Parts No. q w Replacement Parts No. e r t y u i Description Body Bonnet Description Diaphragm assembly Valve assembly Valve spring Valve O-ring O-ring O-ring Common Common Material Aluminum die-casted Polyacetal Material Weather resistant NBR Brass, HNBR Stainless steel NBR NBR NBR Note Chromate treated/ Platinum silver painted Part no. ARM00 ARM000 9A 9A 0. x. x. JIS B 0 P x x. A 9A 0. x 0. x JIS B 0 P x x Individual Component Parts Assembly Description No. Component Regulator o End plate assembly Bracket assembly Individual Common!0!!!!! Regulator End plate R End plate L O-ring Bracket Bracket Bracket A Bracket B Hex. socket head cap screw O-ring Bracket A Bracket B Hex. socket head cap screw Individual Qty. set set Common ARM00 -A-0 A ARM00 Individual ARM00 -B-0 B (Except O-ring) Part no. Common ARM000 -A-0 A ARM000 How to order 00 A () When adding n stations to ARM B Regulator n pcs. Bracket assembly n pcs. () When regulators, end plate assembly and bracket assembly are assembled to make the manifold of n stations. Regulator n pcs. Bracket assembly n pcs. End plate assembly pc. Individual ARM000 -B-0 B (Except O-ring) -- AF AR IR VEX AMR ITV IC VBA VE VY PPA AL

7 Series ARM00/000 Dimensions Pressure gauge (Option) Pressure gauge (Option) (With pressure gauge) Panel mounting hole (Common ) (Individual ) auge port Dimensions Model ARM00 ARM000 A For products with pressure gauge, pressure gauges are shipped together with product. B C D E F H I J K L M N O P Dimensions by the Number of Stations Model ARM00 ARM000 L L L L L L Manifold stations

8 Regulator Single Unit Type Series ARM0. / fitting type Metric size side side Straight Elbow Straight Elbow ø ø ø ø ø ø ø ø Accessory B P B P None Bracket Note ) Note ) Pressure gauge How to Order ARM0 0 B Z Panel nut ( ) ( ) Inch size side side Straight Elbow Straight Elbow ø/ ø/ ø/ ø/ ø/ ø/ ø/ ø/ 9 0 Bracket Note ) In case of a type with bracket, the panel nut is included. Note ) Pressure gauges are not available with the copper-free specification.. Unit representation Z Note) JIS Description Display unit for product name plate and pressure gauge: MPa Display unit for product name plate and pressure gauge: PSI Note) This product is for overseas use only according to the new Measurement Law. (The SI unit type is provided for use in Japan.) Relief type Non-relieving type Panel nut Pressure gauge Specifications. Option None Model Regulator construction Working principal Standard Relief mechanism Optional Backflow function side tubing O.D. side tubing O.D. Proof pressure Maximum operating pressure Standard Regulating pressure range Optional Fluid Ambient and fluid temperature Weight Straight Elbow side side 0. MPa Note ) setting Nonrelieving side side Note ) Oil-free Note ) A pressure gauge with a full span of 0. MPa is attached. Note ) The oil-free type has non-greased fluid contact areas. ARM0 Direct acting Diaphragm regulator Relief type Non-relieving type Within (Unbalance type) ø, ø, ø/, ø/ ø, ø, ø/, ø/.mpa.0mpa 0.0 to 0.MPa 0.0 to 0.MPa (Low pressure type) Air to 0 C 0g Note) When the regulator is used with backflow, operate at a set pressure of 0. MPa or above. F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY PPA AL --9

9 Series ARM0 Flow Characteristics ARM0F -0 ARM0-0 (One-touch fittings: / ø) ARM0F -0 ARM0-0 (One-touch fittings: ø, ø) ARM0F -0 ARM0-0 (One-touch fittings: / ø) Flow rate l/min(anr) Flow rate l/min(anr) Condition: Inlet pressure 0.MPa Condition: Inlet pressure 0.MPa Condition: Inlet pressure 0.MPa ARM0F -0- ARM0-0- (One-touch fittings: / ø) ARM0F -0- ARM0-0- (One-touch fittings: ø, ø) ARM0F -0- ARM0-0- (One-touch fittings: / ø) Condition: Inlet pressure 0.MPa Flow rate l/min(anr) Flow rate l/min(anr) Condition: Inlet pressure 0.MPa Condition: Inlet pressure 0.MPa Flow rate l/min(anr) Flow rate l/min(anr) Pressure Characteristics ARM0F -0 ARM Conditions: Inlet pressure 0.MPa Outlet pressure 0.MPa Flow rate 0l/min (ANR) ARM0F -0- ARM Conditions: Inlet pressure 0.MPa Outlet pressure 0.MPa Flow rate 0l/min (ANR) Set point Set point Inlet pressure MPa Inlet pressure MPa --

10 Regulator Single Unit Type Series ARM0 Construction ARM0 e ARM0F o w t i q ) y. - -, +. i o Component Parts No. Description Material r * u q / Replacement Parts No. Description Material w t e y ) r, * + u / Part no. F.R.L. AV AU AF AR IR VEX q w e r t y u i Body Bonnet Handle Valve seat Adjusting screw assembly Adjustment spring Regulator clip Blanking plate assembly PBT PBT POM POM Reinforced steel Steel wire Stainless steel ) * +, -. / Diaphragm assembly Valve Valve spring O-ring O-ring O-ring Fitting assembly Weatherproof NBR, POM HNBR, Aluminum alloy Stainless steel NBR NBR NBR A -0 Refer to page --. AMR ITV IC VBA o Square nut Steel VE Dimensions VY ARM0-0 0 ø PPA AL PUSH LOCK Panel cutout dimensions For dimensions and accessories of One-touch fittings, please refer to page --. (Max.) Plate thickness: Max Through hole for M ø

11 Regulator/Single Unit Type Option Pressure auge Part no. C-A-X0 C-0A-X0 C-PA-X0 C-P0A-X0 Specifications Fluid Ambient and fluid temperature Display accuracy Calibration angle Limit indicator Weight OPEN Panel Nut V CO ER Part no. Material POM Weight g Pressure gauge indication range Indication unit 0 to 0.MPa MPa 0 to.0mpa 0 to 0PSI PSI 0 to 0PSI Air - to 0 C ±%F.S. (Full Span) 0 With limit indicator g.. ø. One-touch Fittings for Regulator VVQ000-0A One-touch fittings for regulator C C N N ARM0 Straight type Elbow type X X. Straight type Elbow type X ARM0F X 0. Y L Fitting size Fitting type ø ø ø/ ø/ Straight Elbow X Fitting size ø, ø/ ø ø/ Fitting size ø, ø/ ø ø/ Fitting size ø, ø/ ø ø/ Fitting size ø, ø/ ø ø/ C Option None Oil-free X X... X X Y.. Y.. F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY PPA AL (Width across flats of equilateral octagon). Bracket Y ø. Part no. Material Weight Nickel plated steel g. Display Cover R. ø Part no. Material Weight PBT 0.g (R) --

12 Compact Manifold Regulator/Series ARM0/ Specific Product Precautions Be sure to read before handling. Design & Selection. Confirm the specifications. The products appearing in this catalog are designed for use only in compressed air systems. Do not use outside the specified ranges of pressure, temperature, etc., as this may cause damage or faulty operation. Please consult with if fluid other than compressed air is to be used.. Do not use the products in this catalog as safety accessories stipulated in Art., paragraph.. and Art., paragraph. of Pressure Equipment Directive (9//EC). The Pressure Equipment Directive defines a safety accessory as a device which is designed to prevent pressure equipment from exceeding the allowable limit values.. Confirm the regulating pressure range. Be sure to install safety devices if output pressure above the set range can lead to damage or malfunction of equipment on the outlet side.. Residual pressure relief without inlet pressure. In cases where the inlet pressure has been released while the outlet pressure is in a low-pressure setting state, it may not be possible to exhaust the outlet pressure (residual pressure relief). Provide a residual pressure relief circuit if reliable outlet pressure relief must be performed.. When used with a closed downstream circuit and balance circuit. Please contact as there are cases in which the product cannot be used.. Read the instruction manual carefully. The product should be mounted and operated with a good understanding of its contents. Also, keep the manual where it can be easily referred to at any time.. Ensure space for maintenance. Ensure the necessary space for maintenance activities.. Strictly observe the tightening torque of the screw. Tighten the screw at the recommended torque in installation. Mounting Piping Precautions in use of One-touch fittings ) Tubing installation. Take a tubing with no flaws on its periphery and cut it off at a right angle. Use a TK-, or tubing cutter to cut the tubing. Do not use pinchers, nippers or scissors, etc. The tubing might be cut diagonally or flattened, making installation impossible or causing problems such as disconnection and leakage. Also, ensure sufficient tubing length.. Hold the tubing and push it in slowly, inserting it securely all the way into the fitting.. After inserting the tubing, pull it lightly to confirm that it will not come out. If the tubing is not inserted to the end, air leakage or disconnection may occur.. When piping, increase the length of the tubing to allow for any possible warping, increased tension or moment load, etc. to the fittings and tubing. ) Tubing removal. Push both the release bushing and flange.. Pull out the tubing while holding the release bushing so that it will not be locked again. Insufficient pressure on the release bushing will result in increased biting force that will impede the tubing removal.. When re-using a removable tubing, cut of the deformed part. If the deformed part of the tubing is used, it can cause air leakage or impede the tubing removal. In cases where a tubing brand other than is used, confirm that the tubing outside diameter accuracy satisfies the following specifications.. Nylon tubing ±0. mm or less. Soft nylon tubing ±0. mm or less. Polyurethane tubing +0. mm or less/ 0. mm or less Do not use the tubing if it does not satisfy the outside diameter accuracy. Tubing connection may be impossible or air leakage or tubing disconnection may occur after connection. Piping Air Supply. Use clean air. Do not use the regulator if the compressed air contains synthetic oil including chemicals or organic solvents, salt or corrosive gas. It may lead to damage or malfunction.. Install an air filter. Install an air filter on the inlet side in close proximity with the regulator. Select a type with µm or smaller filtration.. Install an after cooler, air dryer or mist separator (drain catch) to remove drainage. Compressed air containing excessive drainage may cause malfunction of the regulator, pressure switch or other pneumatic equipment.. If an excessive amount of carbon powder is generated, install a mist separator as a measure. If an excessive amount of carbon powder is generated from the compressor, it may adhere to the interior of the regulator and cause malfunction. Refer to Best Pneumatics Vol. for further details on compressed air quality. -- F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY PPA AL

13 Compact Manifold Regulator/Series ARM0/ Specific Product Precautions Be sure to read before handling. Operating Environment. Do not operate in locations having an atmosphere of corrosive gases, chemicals, sea water, fresh water or water vapor, or where there will be contact with the same.. In locations which receive direct sunlight, the sunlight should be blocked.. Do not operate in locations where vibration or impact occurs.. Do not operate in a location near a heat source or where radiated heat will be received. Adjustment Regulator. Set up the regulator while verifying the pressure that is indicated on the inlet side and outlet side pressure gauges. Turning the handle excessively could damage the internal parts.. The adjustment handle must be operated manually. Using a tool to turn the handle could lead to damage. Regulator. Set up the regulator after carefully verifying the pressure that is indicated on the inlet side pressure gauge.. Set the outlet pressure in a range that is within % of the inlet pressure. Also, it should not exceed the set pressure range.. Release the lock to adjust the pressure. After the adjustment, engage the lock. Failure to observe this procedure could damage the handle or cause the outlet pressure to fluctuate.. Turning the pressure adjustment handle clockwise increases the outlet pressure and turning it counterclockwise decreases the pressure. (To achieve the final set pressure, gradually increase from low pressure until the desired pressure is reached.) -- How to adjust indicator of the pressure gauge. Make sure to follow the instruction when opening the lens cover to adjust the pressure gauge.. Open the lens cover to the arrow s direction with finger nail. Adjustment OPE. Adjust the gauge needle with for example, a flat head screw driver. COVER. Close the lens cover to the arrow s direction until it snaps on. OP COVER COVER Maintenance To open the lens. To close the lens.. Maintenance should be performed according to the procedure indicated in the instruction manual. Improper handling can cause damage and malfunction of equipment and machinery.. Maintenance operations. Improper handling of compressed air is dangerous. Therefore, in addition to observing the product specifications, replacement of elements and other maintenance activities should be performed by personnel having sufficient knowledge and experience pertaining to pneumatic equipment.. Pre-maintenance inspection. When removing this product, turn off the electric power, and be certain to shut off the supply pressure and exhaust the compressed air in the system. Proceed only after confirming that all pressure has been released to the atmosphere.. Post maintenance inspection. After installation or repair, reconnect compressed air and electricity and conduct appropriate inspections to confirm proper operation. If there is an audible air leakage, or if the equipment does not operate properly, stop operation and confirm that the equipment is installed correctly.. Modification prohibited. Do not modify or reconstruct the unit.

14 Blocks/Series ARM0/ Specific Product Precautions Be sure to read before handling. Observe the proper screw tightening torque in installation. Tightening beyond the proper tightening torque may damage the mounting screws, blocks or switches. If the force is below the tightening torque range, the threaded joint can come loose.. Tightening torque for fixing screws and panel nuts of a single unit regulator. Tightening torque for regulator assembly fixing screws on regulator block. Tightening torque for blanking plates and pressure gauge fixing screws on regulator block 0.±0.0N m ±0.N m 0.±0.0N m 0.±0.0N m Handling One-touch fitting replacement For the ease of replacement, One-touch fittings are installed as the cassette type. One-touch fittings are retained with clips inserted from the directions illustrated blow. Remove the clips with a flat head screw driver to replace the One-touch fittings. When installing, insert each One-touch fitting deeply to the end and reinsert the clip to the specified position.. Single unit regulator. Regulator block. Various common supply blocks F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY PPA AL. Tightening torque for pressure switch fixing screws on common supply block with pressure switch and pressure switch block 0.±0.0N m. Tightening torque for D rail clamp screws on end block.±0.n m Pressure supply of -way valve common supply block Make sure that the handle is set at the OPEN or SHUT position in operation. The block cannot be used for the purpose of containing pressure because it allows a small amount of leakage. SHUT 90 OPEN --9

15 Pressure Switches/Series ARM0/ Specific Product Precautions Be sure to read before handling. Design & Selection. Operate the switch only within the specified voltage. Use of the switch outside the range of the specified voltage can cause malfunction and damage to the switch, it may also increase the risks of electrical shocks or fire.. Never apply a load above the maximum load capacity. It can damage the switch or shorten the service life.. Be sure to observe the set pressure range and maximum operating pressure. Use of the switch outside the set pressure range can cause failure and use beyond the maximum operating pressure can damage the switch.. Do not use the switch unless the equipment operates normally. After installation, repair or reform, connect air and electricity and conduct appropriate function and leakage tests to confirm proper installation.. Do not apply a tensile force to a cord. Be sure to hold the body to handle the product. Applying a tensile force to a cord may cause damage to the product.. Do not drop or bump the product. Dropping or bumping while handling may cause damage to the product. Mounting. Do not use the switch with corrosive gas or liquid. Do not use the switch with corrosive gas or liquid. Such gas or fluid may cause damage to the switch.. Do not use the switch at a vacuum pressure. If used in a vacuum pressure range, the switch will suction the outer air and become unable to operate. Pressure Supply Pressure Setting. The switching setting indication scale shows the set value for pressure decrease.. When the ON pressure signal is to be detected, the ON signal comes on at the pressure found by adding the hysteresis to the pressure set on the scale plate.. The pressure indication on the scale plate is provided as a guideline. Use a pressure gauge to measure the precise settings.. Connect the load Wiring Be sure to connect the load to the pressure switch before connecting the power supply.. Use a contact protection box. If the load driven by the pressure switch is an induction load or connected with a lead wire of m or longer, use a contact protection box in the following table. Contact protection box Operating voltage CD-P 00V AC CD-P V DC. Contact protection box internal circuit CD-P Surge absorber Zener diode. Contact protection box/connection method To connect the switch body and the contact protection box, connect the lead wire of the contact protection box on the side marked with SWITCH and the lead wire from the switch body. Connect the switch body and the contact protection box with a lead wire of m or shorter and arrange them as close as possible.. Lead wire dimensions Covering: ø. Insulator: ø. Conductor: ø0. Choke coil CD-P Choke coil Operating Environment Lead wire length Switch connection side: 0. m Load connection side: 0. m Brown lead wire Blue lead wire Brown lead wire Blue lead wire. Never use in the presence of explosive gases. These switches are not rated as explosion proof. Never use in the presence of an explosive gas as this may cause a serious explosion.. Do not use in an environment where a strong magnetic field is present. The influence of the external magnetic filed may cause the switch to malfunction.. Do not use in an environment where the switch is exposed to water or oil splashes. Because the switch has an open type construction, ingress of water or oil can corrode the electric circuit, resulting in malfunction and damage.. Do not apply vibration to the switch. If vibration is applied, malfunction or setting errors may result. --0

16 Compact Manifold Regulator Common Supply Type Series ARMA How to Order ARMA A 0 A Z. Handle position. / piping position A B C Top Front Bottom Top Front Bottom side Bottom Top side Bottom Top side fitting Elbow Top Bottom side fitting Elbow Top side fitting Straight Bottom side fitting Straight. Regulator block stations. / fitting type (Refer to the figure below.) Metric size Inch size station side side side side stations Straight Elbow Straight Elbow Note) Straight Elbow Straight Elbow stations ø ø ø0 ø ø ø0 ø ø ø ø ø/ ø/ ø/ ø/ ø/ ø/ ø/ ø/ ø/ ø/ stations 0 stations stations 0 9 stations 0 stations stations M 0 stations Note) When the handle and the piping are located on the same side, the elbow fitting is directed to the rear side (D rail side). Handle position: Top piping position: Top Handle position: Bottom piping position: Bottom Front side (Pressure gauge side) Rear side Front side (D rail side) (Pressure gauge side) Rear side (D rail side) --0

17 Compact Manifold Regulator Common Supply Type Series ARMA. Accessory. Option A B C D E F H J K L M N O P Q R Electric Circuit Up to 00 VAC/VDC Set Pressure Range Operating pressure MPa Pressure gauge With None pressure gauge Supply block type Common supply block Common supply block with pressure switch ON pressure -way valve common supply block Supply block mounting position -way valve Common supply block common supply block L side R side B side + Pressure switch block Hysteresis (Left) (Right) (Both) OFF pressure Pressure setting scale L side Note ) Pressure gauges are not available with the copperfree specification. Note ) The oil-free specification is not available for pressure switches. JIS Lead switch -way valve common supply block L side Specifications Common supply block with pressure switch L side -way valve common supply block + Pressure switch block L side Manifold (Regulator block, Common supply block, -way valve common supply block) Regulator construction Working principal Relief mechanism Backflow function side tubing O.D. side tubing O.D. Proof pressure Maximum operating pressure Set pressure range Fluid Ambient and fluid temperature Direct acting Diaphragm regulator Within (Unbalance type) ø, ø, ø0, ø/, ø/, ø/ ø, ø, ø/, ø/. MPa.0 MPa Air to 0 C Standard Standard Relief type 0.0 to 0. MPa Optional Optional Non-relieving type 0.0 to 0. MPa (Low pressure type) Note) When the regulator is used with backflow, operate at a set pressure of 0. MPa or above. Pressure switch (Common supply block with pressure switch, -way valve common supply block + Pressure switch block) Contact mechanism Contact structure Contact configuration Reed switch operating mechanism Wiring specifications Wiring length Proof pressure Maximum operating pressure Set pressure range Hysteresis Repeatability Fluid Ambient and fluid temperature Maximum switching capacity Reed switch mechanism Reed switch mechanism a Piston mechanism (with magnet installed) rommet type 0. m.0 MPa 0. MPa 0. to 0. MPa 0.0 MPa ±0.0 MPa Air to 0 C AC VA, DC W Operating voltage AC/DC Maximum operating current and range Impact resistance V or less 0 ma V 0 ma 0 00 V 0 ma None 0. MPa setting Note ) Nonrelieving Note ) Oil-free Note ) A pressure gauge with a full span of 0. MPa is attached. Note ) The oil-free type has non-greased fluid contact areas.. Unit representation Z Note) Description Display unit for product name plate and pressure gauge: MPa Display unit for product name plate and pressure gauge: PSI Note) This product is for overseas use only according to the new Measurement Law. (The SI unit type is provided for use in Japan.) The pressure switch offers dual unit representation in MPa and PSI. F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY PPA AL --

18 Series ARMA Flow Characteristics ARMAA-0 (One-touch fittings: ø, ø) Inlet pressure 0.MPa ARMAA-0- (One-touch fittings: ø, ø) ARMAA-0 (One-touch fittings: ø, ø) Inlet pressure 0.MPa ARMAA-0- (One-touch fittings: ø, ø) Flow rate l/min(anr) Flow rate l/min(anr) ARMAA- (One-touch fittings: ø0, ø) Inlet pressure 0.MPa ARMAA-- (One-touch fittings: ø0, ø) Flow rate l/min(anr) Condition: Condition: Condition: Flow rate l/min(anr) Flow rate l/min(anr) Condition: Inlet pressure 0.MPa Condition: Inlet pressure 0.MPa Condition: Inlet pressure 0.MPa Flow rate l/min(anr) Pressure Characteristics ARMAA Conditions: Inlet pressure 0.MPa Outlet pressure 0.MPa Flow rate 0l/min (ANR) ARMAA-0-0. Conditions: Inlet pressure 0.MPa Outlet pressure 0.MPa Flow rate 0l/min (ANR) Set point Set point Inlet pressure MPa Inlet pressure MPa --

19 Compact Manifold Regulator Common Supply Type Series ARMA Construction K F.R.L. PUSH LOCK A A-A AV AU AF AR A IR H F E B D 0 VEX AMR ITV IC VBA J C VE VY A 9 PPA Component Parts No. q w e r t y u i o!0! Description Material Body for regulator block PBT Bonnet PBT Handle POM Valve seat POM Adjusting screw assembly Reinforced steel Adjustment spring Steel wire Regulator clip Stainless steel Manifold block PBT Blanking plate assembly Square nut Steel Common exhaust bushing POM Replacement Parts No. A B C D E F H J K Description Diaphragm assembly Valve Valve spring asket O-ring O-ring O-ring O-ring Fitting assembly Port plug Material Weatherproof NBR, POM HNBR, Aluminum alloy Stainless steel HNBR NBR NBR NBR NBR PBT/HNBR Part no. A Refer to page --. Refer to page --. AL --

20 Series ARMA Dimensions ARMAA- Handle position: Top/Common supply block For the dimensions of One-touch fittings and manifold options, please refer to pages -- to --.. L L-0. L=( x n)+ 0. ARMAA- -A Handle position: Top/Common supply block with pressure switch. L L-0. L=( x n) Stations 9 M D rail part no. (for L and R sides) L dimension AXT00-DR-9 AXT00-DR- AXT00-DR- AXT00-DR- 0. AXT00-DR-. AXT00-DR-0 0. AXT00-DR-. AXT00-DR- AXT00-DR- AXT00-DR MPa. 9.. Stations 9 M D rail part no. (for L and R sides) AXT00-DR-9 AXT00-DR- AXT00-DR- AXT00-DR- AXT00-DR- AXT00-DR-0 AXT00-DR- AXT00-DR- AXT00-DR- AXT00-DR-9 L dimension

21 Compact Manifold Regulator Common Supply Type Series ARMA ARMAA- -B Handle position: Top/-way valve common supply block For the dimensions of One-touch fittings and manifold options, please refer to pages -- to ARMAA- -C Handle position: Top/-way valve common supply block + Pressure switch block. L L-0. L=( x n)+ L L-0. L=( x n) Stations 9 M D rail part no. (for L and R sides) AXT00-DR-9 AXT00-DR- AXT00-DR- AXT00-DR- AXT00-DR- AXT00-DR-0 AXT00-DR- AXT00-DR- AXT00-DR- AXT00-DR-9 L dimension F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY PPA AL MPa. 9.. Stations 9 M D rail part no. AXT00-DR- AXT00-DR- AXT00-DR- AXT00-DR- AXT00-DR-9 AXT00-DR- AXT00-DR- AXT00-DR- AXT00-DR- AXT00-DR- L dimension

22 Series ARMA Dimensions ARMAB- Handle position: Front/Common supply block For the dimensions of One-touch fittings and manifold options, please refer to pages -- to --.. L L-0. L=( x n)+ 0.. PUSH LOCK PUSH LOCK.. Stations 9 M D rail part no. AXT00-DR-9 AXT00-DR- AXT00-DR- AXT00-DR- AXT00-DR- AXT00-DR-0 AXT00-DR- AXT00-DR- AXT00-DR- AXT00-DR-9 L dimension ARMAB- -A Handle position: Front/Common supply block with pressure switch. L L-0. L=( x n) PUSH LOCK PUSH LOCK.. Stations 9 M D rail part no. AXT00-DR-9 AXT00-DR- AXT00-DR- AXT00-DR- AXT00-DR- AXT00-DR-0 AXT00-DR- AXT00-DR- AXT00-DR- AXT00-DR-9 L dimension

23 Compact Manifold Regulator Common Supply Type Series ARMA ARMAB- -B Handle position: Front/-way valve common supply block For the dimensions of One-touch fittings and manifold options, please refer to pages -- to --.. L L-0. L=( x n)+. F.R.L. AV. AU AF. PUSH L OCK PUSH L OCK AR IR. Stations 9 M D rail part no. AXT00-DR-9 AXT00-DR- AXT00-DR- AXT00-DR- AXT00-DR- AXT00-DR-0 AXT00-DR- AXT00-DR- AXT00-DR- AXT00-DR-9 L dimension VEX AMR ITV IC VBA VE ARMAB- -C Handle position: Front/-way valve common supply block + Pressure switch block VY. L L-0. L=( x n)+ 0. PPA AL MPa PUSH L OCK PUSH L OCK.. Stations 9 M D rail part no. AXT00-DR- AXT00-DR- AXT00-DR- AXT00-DR- AXT00-DR-9 AXT00-DR- AXT00-DR- AXT00-DR- AXT00-DR- AXT00-DR- L dimension

24 Series ARMA Dimensions ARMAC- Handle position: Bottom/Common supply block For the dimensions of One-touch fittings and manifold options, please refer to pages -- to L L-0. L=( x n) PUSH L OCK PUSH L OCK Stations 9 M D rail part no. AXT00-DR-9 AXT00-DR- AXT00-DR- AXT00-DR- AXT00-DR- AXT00-DR-0 AXT00-DR- AXT00-DR- AXT00-DR- AXT00-DR-9 L dimension ARMAC- -A Handle position: Bottom/Common supply block with pressure switch. L L-0. L=( x n) MPa. PUSH L OCK PUSH L OCK. Stations 9 M D rail part no. AXT00-DR-9 AXT00-DR- AXT00-DR- AXT00-DR- AXT00-DR- AXT00-DR-0 AXT00-DR- AXT00-DR- AXT00-DR- AXT00-DR-9 L dimension

25 Compact Manifold Regulator Common Supply Type Series ARMA ARMAC- -B Handle position: Bottom/-way valve common supply block For the dimensions of One-touch fittings and manifold options, please refer to pages -- to L L-0. L=( x n)+ ARMAC- -C Handle position: Bottom/-way valve common supply block + Pressure switch block. PUSH L OCK L L-0. L=( x n)+ 0 PUSH L OCK. Stations 9 M D rail part no. AXT00-DR-9 AXT00-DR- AXT00-DR- AXT00-DR- AXT00-DR- AXT00-DR-0 AXT00-DR- AXT00-DR- AXT00-DR- AXT00-DR-9 L dimension F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY PPA AL MPa. PUSH L OCK PUSH L OCK. Stations 9 M D rail part no. AXT00-DR- AXT00-DR- AXT00-DR- AXT00-DR- AXT00-DR-9 AXT00-DR- AXT00-DR- AXT00-DR- AXT00-DR- AXT00-DR- L dimension

26 Compact Manifold Regulator Option Common Supply Type R side end block Pressure gauge Pressure switch block Common supply block One-touch fitting for regulator block L side end block Port plug Regulator block Common supply bushing One-touch fitting for common supply block D rail Individual Supply Type R side end block Pressure gauge One-touch fitting for regulator block L side end block Individual supply bushing Regulator block D rail --

27 Compact Manifold Regulator/Series ARM0/ Specific Product Precautions Be sure to read before handling. Design & Selection. Confirm the specifications. The products appearing in this catalog are designed for use only in compressed air systems. Do not use outside the specified ranges of pressure, temperature, etc., as this may cause damage or faulty operation. Please consult with if fluid other than compressed air is to be used.. Do not use the products in this catalog as safety accessories stipulated in Art., paragraph.. and Art., paragraph. of Pressure Equipment Directive (9//EC). The Pressure Equipment Directive defines a safety accessory as a device which is designed to prevent pressure equipment from exceeding the allowable limit values.. Confirm the regulating pressure range. Be sure to install safety devices if output pressure above the set range can lead to damage or malfunction of equipment on the outlet side.. Residual pressure relief without inlet pressure. In cases where the inlet pressure has been released while the outlet pressure is in a low-pressure setting state, it may not be possible to exhaust the outlet pressure (residual pressure relief). Provide a residual pressure relief circuit if reliable outlet pressure relief must be performed.. When used with a closed downstream circuit and balance circuit. Please contact as there are cases in which the product cannot be used.. Read the instruction manual carefully. The product should be mounted and operated with a good understanding of its contents. Also, keep the manual where it can be easily referred to at any time.. Ensure space for maintenance. Ensure the necessary space for maintenance activities.. Strictly observe the tightening torque of the screw. Tighten the screw at the recommended torque in installation. Mounting Piping Precautions in use of One-touch fittings ) Tubing installation. Take a tubing with no flaws on its periphery and cut it off at a right angle. Use a TK-, or tubing cutter to cut the tubing. Do not use pinchers, nippers or scissors, etc. The tubing might be cut diagonally or flattened, making installation impossible or causing problems such as disconnection and leakage. Also, ensure sufficient tubing length.. Hold the tubing and push it in slowly, inserting it securely all the way into the fitting.. After inserting the tubing, pull it lightly to confirm that it will not come out. If the tubing is not inserted to the end, air leakage or disconnection may occur.. When piping, increase the length of the tubing to allow for any possible warping, increased tension or moment load, etc. to the fittings and tubing. ) Tubing removal. Push both the release bushing and flange.. Pull out the tubing while holding the release bushing so that it will not be locked again. Insufficient pressure on the release bushing will result in increased biting force that will impede the tubing removal.. When re-using a removable tubing, cut of the deformed part. If the deformed part of the tubing is used, it can cause air leakage or impede the tubing removal. In cases where a tubing brand other than is used, confirm that the tubing outside diameter accuracy satisfies the following specifications.. Nylon tubing ±0. mm or less. Soft nylon tubing ±0. mm or less. Polyurethane tubing +0. mm or less/ 0. mm or less Do not use the tubing if it does not satisfy the outside diameter accuracy. Tubing connection may be impossible or air leakage or tubing disconnection may occur after connection. Piping Air Supply. Use clean air. Do not use the regulator if the compressed air contains synthetic oil including chemicals or organic solvents, salt or corrosive gas. It may lead to damage or malfunction.. Install an air filter. Install an air filter on the inlet side in close proximity with the regulator. Select a type with µm or smaller filtration.. Install an after cooler, air dryer or mist separator (drain catch) to remove drainage. Compressed air containing excessive drainage may cause malfunction of the regulator, pressure switch or other pneumatic equipment.. If an excessive amount of carbon powder is generated, install a mist separator as a measure. If an excessive amount of carbon powder is generated from the compressor, it may adhere to the interior of the regulator and cause malfunction. Refer to Best Pneumatics Vol. for further details on compressed air quality. -- F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY PPA AL

28 Compact Manifold Regulator/Series ARM0/ Specific Product Precautions Be sure to read before handling. Operating Environment. Do not operate in locations having an atmosphere of corrosive gases, chemicals, sea water, fresh water or water vapor, or where there will be contact with the same.. In locations which receive direct sunlight, the sunlight should be blocked.. Do not operate in locations where vibration or impact occurs.. Do not operate in a location near a heat source or where radiated heat will be received. Adjustment Regulator. Set up the regulator while verifying the pressure that is indicated on the inlet side and outlet side pressure gauges. Turning the handle excessively could damage the internal parts.. The adjustment handle must be operated manually. Using a tool to turn the handle could lead to damage. Regulator. Set up the regulator after carefully verifying the pressure that is indicated on the inlet side pressure gauge.. Set the outlet pressure in a range that is within % of the inlet pressure. Also, it should not exceed the set pressure range.. Release the lock to adjust the pressure. After the adjustment, engage the lock. Failure to observe this procedure could damage the handle or cause the outlet pressure to fluctuate.. Turning the pressure adjustment handle clockwise increases the outlet pressure and turning it counterclockwise decreases the pressure. (To achieve the final set pressure, gradually increase from low pressure until the desired pressure is reached.) -- How to adjust indicator of the pressure gauge. Make sure to follow the instruction when opening the lens cover to adjust the pressure gauge.. Open the lens cover to the arrow s direction with finger nail. Adjustment OPE. Adjust the gauge needle with for example, a flat head screw driver. COVER. Close the lens cover to the arrow s direction until it snaps on. OP COVER COVER Maintenance To open the lens. To close the lens.. Maintenance should be performed according to the procedure indicated in the instruction manual. Improper handling can cause damage and malfunction of equipment and machinery.. Maintenance operations. Improper handling of compressed air is dangerous. Therefore, in addition to observing the product specifications, replacement of elements and other maintenance activities should be performed by personnel having sufficient knowledge and experience pertaining to pneumatic equipment.. Pre-maintenance inspection. When removing this product, turn off the electric power, and be certain to shut off the supply pressure and exhaust the compressed air in the system. Proceed only after confirming that all pressure has been released to the atmosphere.. Post maintenance inspection. After installation or repair, reconnect compressed air and electricity and conduct appropriate inspections to confirm proper operation. If there is an audible air leakage, or if the equipment does not operate properly, stop operation and confirm that the equipment is installed correctly.. Modification prohibited. Do not modify or reconstruct the unit.

29 Blocks/Series ARM0/ Specific Product Precautions Be sure to read before handling. Observe the proper screw tightening torque in installation. Tightening beyond the proper tightening torque may damage the mounting screws, blocks or switches. If the force is below the tightening torque range, the threaded joint can come loose.. Tightening torque for fixing screws and panel nuts of a single unit regulator. Tightening torque for regulator assembly fixing screws on regulator block. Tightening torque for blanking plates and pressure gauge fixing screws on regulator block 0.±0.0N m ±0.N m 0.±0.0N m 0.±0.0N m Handling One-touch fitting replacement For the ease of replacement, One-touch fittings are installed as the cassette type. One-touch fittings are retained with clips inserted from the directions illustrated blow. Remove the clips with a flat head screw driver to replace the One-touch fittings. When installing, insert each One-touch fitting deeply to the end and reinsert the clip to the specified position.. Single unit regulator. Regulator block. Various common supply blocks F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY PPA AL. Tightening torque for pressure switch fixing screws on common supply block with pressure switch and pressure switch block 0.±0.0N m. Tightening torque for D rail clamp screws on end block.±0.n m Pressure supply of -way valve common supply block Make sure that the handle is set at the OPEN or SHUT position in operation. The block cannot be used for the purpose of containing pressure because it allows a small amount of leakage. SHUT 90 OPEN --9

30 Pressure Switches/Series ARM0/ Specific Product Precautions Be sure to read before handling. Design & Selection. Operate the switch only within the specified voltage. Use of the switch outside the range of the specified voltage can cause malfunction and damage to the switch, it may also increase the risks of electrical shocks or fire.. Never apply a load above the maximum load capacity. It can damage the switch or shorten the service life.. Be sure to observe the set pressure range and maximum operating pressure. Use of the switch outside the set pressure range can cause failure and use beyond the maximum operating pressure can damage the switch.. Do not use the switch unless the equipment operates normally. After installation, repair or reform, connect air and electricity and conduct appropriate function and leakage tests to confirm proper installation.. Do not apply a tensile force to a cord. Be sure to hold the body to handle the product. Applying a tensile force to a cord may cause damage to the product.. Do not drop or bump the product. Dropping or bumping while handling may cause damage to the product. Mounting. Do not use the switch with corrosive gas or liquid. Do not use the switch with corrosive gas or liquid. Such gas or fluid may cause damage to the switch.. Do not use the switch at a vacuum pressure. If used in a vacuum pressure range, the switch will suction the outer air and become unable to operate. Pressure Supply Pressure Setting. The switching setting indication scale shows the set value for pressure decrease.. When the ON pressure signal is to be detected, the ON signal comes on at the pressure found by adding the hysteresis to the pressure set on the scale plate.. The pressure indication on the scale plate is provided as a guideline. Use a pressure gauge to measure the precise settings.. Connect the load Wiring Be sure to connect the load to the pressure switch before connecting the power supply.. Use a contact protection box. If the load driven by the pressure switch is an induction load or connected with a lead wire of m or longer, use a contact protection box in the following table. Contact protection box Operating voltage CD-P 00V AC CD-P V DC. Contact protection box internal circuit CD-P Surge absorber Zener diode. Contact protection box/connection method To connect the switch body and the contact protection box, connect the lead wire of the contact protection box on the side marked with SWITCH and the lead wire from the switch body. Connect the switch body and the contact protection box with a lead wire of m or shorter and arrange them as close as possible.. Lead wire dimensions Covering: ø. Insulator: ø. Conductor: ø0. Choke coil CD-P Choke coil Operating Environment Lead wire length Switch connection side: 0. m Load connection side: 0. m Brown lead wire Blue lead wire Brown lead wire Blue lead wire. Never use in the presence of explosive gases. These switches are not rated as explosion proof. Never use in the presence of an explosive gas as this may cause a serious explosion.. Do not use in an environment where a strong magnetic field is present. The influence of the external magnetic filed may cause the switch to malfunction.. Do not use in an environment where the switch is exposed to water or oil splashes. Because the switch has an open type construction, ingress of water or oil can corrode the electric circuit, resulting in malfunction and damage.. Do not apply vibration to the switch. If vibration is applied, malfunction or setting errors may result. --0

31 Compact Manifold Regulator Individual Supply Type Series ARMB. Handle position A B C Top Front Bottom How to Order ARMB A 0 A Z Top Front Bottom. / piping position side Bottom Top side Bottom Top /: Bottom /: Top : Bottom : Top : Top : Bottom. Regulator block stations 9 M. Accessory. Option station stations stations stations stations stations stations stations 9 stations 0 stations Without pressure gauge A With pressure gauge Note) Pressure gauges are not available with the copperfree specification. Note ) A pressure gauge with a full span of 0. MPa is attached. Note ) The oil-free type has non-greased fluid contact areas.. Unit representation Z Note) None 0. MPa Note ) setting Nonrelieving Note ) Oil-free Description Display unit for product name plate and pressure gauge: MPa Display unit for product name plate and pressure gauge: PSI Note) This product is for overseas use only according to the new Measurement Law. (The SI unit type is provided for use in Japan.). / fitting type Metric size side side Straight Elbow Straight Elbow Note) ø ø ø ø ø ø ø ø JIS Inch size side side Straight Elbow Straight Elbow ø/ ø/ ø/ ø/ ø/ ø/ ø/ ø/ 9 0 Note) When the handle and the piping are located on the same side, the elbow fitting is directed to the rear side (D rail side). Front side (Pressure gauge side) Handle position: Top piping position: Top Rear side (D rail side) Front side (Pressure gauge side) Handle position: Bottom piping position: Bottom Rear side (D rail side) --0

32 Compact Manifold Regulator Individual Supply Type Series ARMB Specifications Regulator construction Working principal Standard Relief mechanism Optional Backflow function side tubing O.D. side tubing O.D. Proof pressure Maximum operating pressure Standard Set pressure range Optional Fluid Ambient and fluid temperature Note) When the regulator is used with backflow, operate at a set pressure of 0. MPa or above. Construction PUSH LOCK K e A y r F E H B! Direct acting Diaphragm regulator Relief type Non-relieving type Within (Unbalance type) ø, ø, ø/, ø/ ø, ø, ø/, ø/.mpa.0mpa 0.0 to 0.MPa 0.0 to 0.MPa (Low pressure type) Air to 0 C t A-A w F i D!0 u F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY PPA AL q C J o Component Parts No. q w e r t y u i o!0! Description Body for regulator block Bonnet Handle Valve seat Adjusting screw assembly Adjustment spring Regulator clip Manifold block Blanking plate assembly Square nut Individual supply bushing A Material PBT PBT POM POM Reinforced steel Steel wire Stainless steel PBT Steel POM Replacement Parts No. A B C D E F H J K Description Diaphragm assembly Valve Valve spring asket O-ring O-ring O-ring O-ring Fitting assembly Port plug Material Weatherproof NBR, POM HNBR, Aluminum alloy Stainless steel HNBR NBR NBR NBR NBR PBT/HNBR Part no. A Refer to page --. Refer to page

33 Series ARMB Flow Characteristics ARMBA-0 (One-touch fittings: / ø) Inlet pressure 0.MPa ARMBA-0- (One-touch fittings: / ø) Condition: Condition: Inlet pressure 0.MPa Flow rate l/min(anr) Flow rate l/min(anr) ARMBA-0 (One-touch fittings: ø, ø) Inlet pressure 0.MPa ARMBA-0- (One-touch fittings: ø, ø) Condition: Condition: Inlet pressure 0.MPa Flow rate l/min(anr) Flow rate l/min(anr) ARMBA-0 (One-touch fittings: / ø) Inlet pressure 0.MPa ARMBA-0- (One-touch fittings: / ø) Condition: Condition: Inlet pressure 0.MPa Flow rate l/min(anr) Flow rate l/min(anr) Pressure Characteristics ARMBA Conditions: Inlet pressure 0.MPa Outlet pressure 0.MPa Flow rate 0l/min (ANR) ARMBA-0-0. Conditions: Inlet pressure 0.MPa Outlet pressure 0.MPa Flow rate 0l/min (ANR) Set point Set point Inlet pressure MPa Inlet pressure MPa --

34 Compact Manifold Regulator Individual Supply Type Series ARMB Dimensions ARMBA- 0 Handle position: Top. L L-0. L=( x n) Stations 9 M D rail part no. AXT00-DR- AXT00-DR-0 AXT00-DR- AXT00-DR- AXT00-DR- AXT00-DR-9 AXT00-DR- AXT00-DR- AXT00-DR- AXT00-DR- L dimension F.R.L. AV AU AF AR IR VEX ARMBB- 0 Handle position: Front. L L-0. L=( x n)+. AMR ITV IC VBA... PUSH LOCK PUSH LOCK Stations 9 M D rail part no. AXT00-DR- AXT00-DR-0 AXT00-DR- AXT00-DR- AXT00-DR- AXT00-DR-9 AXT00-DR- AXT00-DR- AXT00-DR- AXT00-DR- L dimension VE VY PPA AL ARMBC- 0 Handle position: Bottom. L L-0. L=( x n) PUSH LOCK PUSH LOCK Stations 9 M D rail part no. AXT00-DR- AXT00-DR-0 AXT00-DR- AXT00-DR- AXT00-DR- AXT00-DR-9 AXT00-DR- AXT00-DR- AXT00-DR- AXT00-DR- L dimension

35 Compact Manifold Regulator Option Common Supply Type R side end block Pressure gauge Pressure switch block Common supply block One-touch fitting for regulator block L side end block Port plug Regulator block Common supply bushing One-touch fitting for common supply block D rail Individual Supply Type R side end block Pressure gauge One-touch fitting for regulator block L side end block Individual supply bushing Regulator block D rail --

36 Compact Manifold Regulator/Series ARM0/ Specific Product Precautions Be sure to read before handling. Design & Selection. Confirm the specifications. The products appearing in this catalog are designed for use only in compressed air systems. Do not use outside the specified ranges of pressure, temperature, etc., as this may cause damage or faulty operation. Please consult with if fluid other than compressed air is to be used.. Do not use the products in this catalog as safety accessories stipulated in Art., paragraph.. and Art., paragraph. of Pressure Equipment Directive (9//EC). The Pressure Equipment Directive defines a safety accessory as a device which is designed to prevent pressure equipment from exceeding the allowable limit values.. Confirm the regulating pressure range. Be sure to install safety devices if output pressure above the set range can lead to damage or malfunction of equipment on the outlet side.. Residual pressure relief without inlet pressure. In cases where the inlet pressure has been released while the outlet pressure is in a low-pressure setting state, it may not be possible to exhaust the outlet pressure (residual pressure relief). Provide a residual pressure relief circuit if reliable outlet pressure relief must be performed.. When used with a closed downstream circuit and balance circuit. Please contact as there are cases in which the product cannot be used.. Read the instruction manual carefully. The product should be mounted and operated with a good understanding of its contents. Also, keep the manual where it can be easily referred to at any time.. Ensure space for maintenance. Ensure the necessary space for maintenance activities.. Strictly observe the tightening torque of the screw. Tighten the screw at the recommended torque in installation. Mounting Piping Precautions in use of One-touch fittings ) Tubing installation. Take a tubing with no flaws on its periphery and cut it off at a right angle. Use a TK-, or tubing cutter to cut the tubing. Do not use pinchers, nippers or scissors, etc. The tubing might be cut diagonally or flattened, making installation impossible or causing problems such as disconnection and leakage. Also, ensure sufficient tubing length.. Hold the tubing and push it in slowly, inserting it securely all the way into the fitting.. After inserting the tubing, pull it lightly to confirm that it will not come out. If the tubing is not inserted to the end, air leakage or disconnection may occur.. When piping, increase the length of the tubing to allow for any possible warping, increased tension or moment load, etc. to the fittings and tubing. ) Tubing removal. Push both the release bushing and flange.. Pull out the tubing while holding the release bushing so that it will not be locked again. Insufficient pressure on the release bushing will result in increased biting force that will impede the tubing removal.. When re-using a removable tubing, cut of the deformed part. If the deformed part of the tubing is used, it can cause air leakage or impede the tubing removal. In cases where a tubing brand other than is used, confirm that the tubing outside diameter accuracy satisfies the following specifications.. Nylon tubing ±0. mm or less. Soft nylon tubing ±0. mm or less. Polyurethane tubing +0. mm or less/ 0. mm or less Do not use the tubing if it does not satisfy the outside diameter accuracy. Tubing connection may be impossible or air leakage or tubing disconnection may occur after connection. Piping Air Supply. Use clean air. Do not use the regulator if the compressed air contains synthetic oil including chemicals or organic solvents, salt or corrosive gas. It may lead to damage or malfunction.. Install an air filter. Install an air filter on the inlet side in close proximity with the regulator. Select a type with µm or smaller filtration.. Install an after cooler, air dryer or mist separator (drain catch) to remove drainage. Compressed air containing excessive drainage may cause malfunction of the regulator, pressure switch or other pneumatic equipment.. If an excessive amount of carbon powder is generated, install a mist separator as a measure. If an excessive amount of carbon powder is generated from the compressor, it may adhere to the interior of the regulator and cause malfunction. Refer to Best Pneumatics Vol. for further details on compressed air quality. -- F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY PPA AL

37 Compact Manifold Regulator/Series ARM0/ Specific Product Precautions Be sure to read before handling. Operating Environment. Do not operate in locations having an atmosphere of corrosive gases, chemicals, sea water, fresh water or water vapor, or where there will be contact with the same.. In locations which receive direct sunlight, the sunlight should be blocked.. Do not operate in locations where vibration or impact occurs.. Do not operate in a location near a heat source or where radiated heat will be received. Adjustment Regulator. Set up the regulator while verifying the pressure that is indicated on the inlet side and outlet side pressure gauges. Turning the handle excessively could damage the internal parts.. The adjustment handle must be operated manually. Using a tool to turn the handle could lead to damage. Regulator. Set up the regulator after carefully verifying the pressure that is indicated on the inlet side pressure gauge.. Set the outlet pressure in a range that is within % of the inlet pressure. Also, it should not exceed the set pressure range.. Release the lock to adjust the pressure. After the adjustment, engage the lock. Failure to observe this procedure could damage the handle or cause the outlet pressure to fluctuate.. Turning the pressure adjustment handle clockwise increases the outlet pressure and turning it counterclockwise decreases the pressure. (To achieve the final set pressure, gradually increase from low pressure until the desired pressure is reached.) -- How to adjust indicator of the pressure gauge. Make sure to follow the instruction when opening the lens cover to adjust the pressure gauge.. Open the lens cover to the arrow s direction with finger nail. Adjustment OPE. Adjust the gauge needle with for example, a flat head screw driver. COVER. Close the lens cover to the arrow s direction until it snaps on. OP COVER COVER Maintenance To open the lens. To close the lens.. Maintenance should be performed according to the procedure indicated in the instruction manual. Improper handling can cause damage and malfunction of equipment and machinery.. Maintenance operations. Improper handling of compressed air is dangerous. Therefore, in addition to observing the product specifications, replacement of elements and other maintenance activities should be performed by personnel having sufficient knowledge and experience pertaining to pneumatic equipment.. Pre-maintenance inspection. When removing this product, turn off the electric power, and be certain to shut off the supply pressure and exhaust the compressed air in the system. Proceed only after confirming that all pressure has been released to the atmosphere.. Post maintenance inspection. After installation or repair, reconnect compressed air and electricity and conduct appropriate inspections to confirm proper operation. If there is an audible air leakage, or if the equipment does not operate properly, stop operation and confirm that the equipment is installed correctly.. Modification prohibited. Do not modify or reconstruct the unit.

38 Blocks/Series ARM0/ Specific Product Precautions Be sure to read before handling. Observe the proper screw tightening torque in installation. Tightening beyond the proper tightening torque may damage the mounting screws, blocks or switches. If the force is below the tightening torque range, the threaded joint can come loose.. Tightening torque for fixing screws and panel nuts of a single unit regulator. Tightening torque for regulator assembly fixing screws on regulator block. Tightening torque for blanking plates and pressure gauge fixing screws on regulator block 0.±0.0N m ±0.N m 0.±0.0N m 0.±0.0N m Handling One-touch fitting replacement For the ease of replacement, One-touch fittings are installed as the cassette type. One-touch fittings are retained with clips inserted from the directions illustrated blow. Remove the clips with a flat head screw driver to replace the One-touch fittings. When installing, insert each One-touch fitting deeply to the end and reinsert the clip to the specified position.. Single unit regulator. Regulator block. Various common supply blocks F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY PPA AL. Tightening torque for pressure switch fixing screws on common supply block with pressure switch and pressure switch block 0.±0.0N m. Tightening torque for D rail clamp screws on end block.±0.n m Pressure supply of -way valve common supply block Make sure that the handle is set at the OPEN or SHUT position in operation. The block cannot be used for the purpose of containing pressure because it allows a small amount of leakage. SHUT 90 OPEN --9

39 Pressure Switches/Series ARM0/ Specific Product Precautions Be sure to read before handling. Design & Selection. Operate the switch only within the specified voltage. Use of the switch outside the range of the specified voltage can cause malfunction and damage to the switch, it may also increase the risks of electrical shocks or fire.. Never apply a load above the maximum load capacity. It can damage the switch or shorten the service life.. Be sure to observe the set pressure range and maximum operating pressure. Use of the switch outside the set pressure range can cause failure and use beyond the maximum operating pressure can damage the switch.. Do not use the switch unless the equipment operates normally. After installation, repair or reform, connect air and electricity and conduct appropriate function and leakage tests to confirm proper installation.. Do not apply a tensile force to a cord. Be sure to hold the body to handle the product. Applying a tensile force to a cord may cause damage to the product.. Do not drop or bump the product. Dropping or bumping while handling may cause damage to the product. Mounting. Do not use the switch with corrosive gas or liquid. Do not use the switch with corrosive gas or liquid. Such gas or fluid may cause damage to the switch.. Do not use the switch at a vacuum pressure. If used in a vacuum pressure range, the switch will suction the outer air and become unable to operate. Pressure Supply Pressure Setting. The switching setting indication scale shows the set value for pressure decrease.. When the ON pressure signal is to be detected, the ON signal comes on at the pressure found by adding the hysteresis to the pressure set on the scale plate.. The pressure indication on the scale plate is provided as a guideline. Use a pressure gauge to measure the precise settings.. Connect the load Wiring Be sure to connect the load to the pressure switch before connecting the power supply.. Use a contact protection box. If the load driven by the pressure switch is an induction load or connected with a lead wire of m or longer, use a contact protection box in the following table. Contact protection box Operating voltage CD-P 00V AC CD-P V DC. Contact protection box internal circuit CD-P Surge absorber Zener diode. Contact protection box/connection method To connect the switch body and the contact protection box, connect the lead wire of the contact protection box on the side marked with SWITCH and the lead wire from the switch body. Connect the switch body and the contact protection box with a lead wire of m or shorter and arrange them as close as possible.. Lead wire dimensions Covering: ø. Insulator: ø. Conductor: ø0. Choke coil CD-P Choke coil Operating Environment Lead wire length Switch connection side: 0. m Load connection side: 0. m Brown lead wire Blue lead wire Brown lead wire Blue lead wire. Never use in the presence of explosive gases. These switches are not rated as explosion proof. Never use in the presence of an explosive gas as this may cause a serious explosion.. Do not use in an environment where a strong magnetic field is present. The influence of the external magnetic filed may cause the switch to malfunction.. Do not use in an environment where the switch is exposed to water or oil splashes. Because the switch has an open type construction, ingress of water or oil can corrode the electric circuit, resulting in malfunction and damage.. Do not apply vibration to the switch. If vibration is applied, malfunction or setting errors may result. --0

40 Compact Manifold Regulator Common/Individual Supply Type Series ARMA/B Regulator Block Common supply type. Handle position A B C Top Front Bottom. piping position Bottom Top. fitting type Metric size Straight Elbow ø 0 0 ø ø ø Individual supply type. Handle position A B C Top Front Bottom Handle position Top. ARMA A R 0 A 0. Accessory Inch size Straight Elbow ø/ ø/ ø/ ø/ Handle position Front Without pressure gauge A With pressure gauge Note) Pressure gauges are not available with the copper-free specification.. Option None 0. MPa Note ) setting Handle position Bottom 0 (Max.) Nonrelieving Oil-free Note ) A pressure gauge with a full span of 0. MPa is attached. Note ) The oil-free type has nongreased fluid contact areas. ARMB A R 0 A Handle position Top Handle position Front Handle position Bottom 0 0 (Max.) PUSH L OCK PUSH L OCK Z Z. Unit representation Z Description Display unit for product name plate and pressure gauge: MPa Display unit for product name plate and pressure gauge: PSI F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY PPA AL. / piping position side Bottom. Accessory A Top Without pressure gauge With pressure gauge Note) Pressure gauges are not available with the copper-free specification. side Bottom Top. / fitting type Metric size side side Straight Elbow Straight Elbow ø ø ø ø ø ø ø ø Inch size side side Straight Elbow Straight Elbow ø/ ø/ ø/ ø/ ø/ ø/ ø/ ø/ 9 0. Option None 0. MPa Note ) setting Note ) A pressure gauge with a full span of 0. MPa is attached. Note ) The oil-free type has non-greased fluid contact areas.. Unit representation Nonrelieving Oil-free Description Display unit for product name plate and pressure gauge: MPa Display unit for product name Z Note) plate and pressure gauge: PSI Note) This product is for overseas use only according to the new Measurement Law. (The SI unit type is provided for use in Japan.) --

41 MPa MPa MPa Series ARMA/B Common Supply Block. piping position Bottom Top. fitting type Metric size Straight ø 0 ø ø0 0 0 ARMA S 0. Option None Oil-free Note) The oil-free type has non-greased fluid contact areas. Inch size Elbow Straight Elbow ø ø ø0 ø/ ø/ ø/ ø/ ø/ ø/ A. Common supply block type S Common supply block P Common supply block with pressure switch V -way valve common supply block W -way valve common supply block + Pressure switch block Note) The oil-free specification is not available for P and W types of common supply blocks (types with pressure switch). Common supply block (S) Z Common supply block with pressure switch (P). Accessory Pressure switch lead wire length: 0. m A Pressure switch lead wire length:.0 m Note) Leave the field blank for types without pressure switch. -way valve common supply block (V) -way valve common supply block + Pressure switch block (W). Unit representation Z Note) Description Display unit for product name plate: MPa Display unit for product name plate: PSI Note) This product is for overseas use only according to the new Measurement Law. (The SI unit type is provided for use in Japan.) The pressure switch offers dual unit representation in MPa and PSI. Pressure Switch Block ARMAW A Z. Accessory. Unit representation A Pressure switch lead wire length: 0. m Pressure switch lead wire length:.0 m Z Note) Description Display unit for product name plate: MPa Display unit for product name plate: PSI Note) This product is for overseas use only according to the new Measurement Law. (The SI unit type is provided for use in Japan.) The pressure switch offers dual unit representation in MPa and PSI. --

42 Compact Manifold Regulator Common/Individual Supply Type Series ARMA/B D Rail When only D rail is required: D rail part no. AXT00- DR - n Note) Put an appropriate No. from the table below in the place of n. For the L dimension, please refer to Dimensions. L. P=... F.R.L. AV AU. AF L Dimension NO. L L=. x n AR IR NO. L VEX NO. L AMR NO. L ITV IC One-touch Fittings for Regulator Block VVQ000 0A One-touch fittings for regulator block C C N N L Fitting size ø ø ø/ ø/ Fitting type Straight Elbow X C Option None Oil-free One-touch Fittings for Common Supply Block VVQ000 A One-touch fittings for regulator C C C0 N N9 N L Fitting size ø ø ø0 ø/ ø/ ø/ Fitting type Straight Elbow X C VBA VE VY PPA AL X X. X X. Option None Oil-free Straight type Elbow type Straight type Elbow type Y Y Fitting size ø, ø/ ø ø/ X Fitting size ø, ø/ ø ø/ X... Y 9 9. Fitting size ø ø, ø/ ø0, ø/ ø/ X. Fitting size ø ø, ø/ ø0, ø/ ø/ X Y

43 Series ARMA/B End Block ARME End block End block type Mounting position L Left side R Right side L side end block L Option None Oil-free Note ) Since the L side end block is oil-free, leave the field blank for it. R side end block Pressure auge Part no. Pressure gauge indication range Indication unit C-A-X0 C-PA-X0 0 to 0. MPa 0 to 0 PSI C-0A-X0 C-P0A-X0 0 to.0 MPa 0 to 0 PSI MPa PSI Specifications Fluid Air Ambient and fluid temperature - to 0 C Display accuracy ±%F.S. (Full Span) Calibration angle 0 Limit indicator With limit indicator. OPEN Port Plug VVQ0000 A Single unit regulator / Port plug for regulator block X Option None Oil-free Bushing Part no. -S -K Description Common supply bushing Individual supply bushing -S -K A A-A A A-A ø. V CO ER ø0. 0 A A --

44 Compact Manifold Regulator/Series ARM0/ Specific Product Precautions Be sure to read before handling. Design & Selection. Confirm the specifications. The products appearing in this catalog are designed for use only in compressed air systems. Do not use outside the specified ranges of pressure, temperature, etc., as this may cause damage or faulty operation. Please consult with if fluid other than compressed air is to be used.. Do not use the products in this catalog as safety accessories stipulated in Art., paragraph.. and Art., paragraph. of Pressure Equipment Directive (9//EC). The Pressure Equipment Directive defines a safety accessory as a device which is designed to prevent pressure equipment from exceeding the allowable limit values.. Confirm the regulating pressure range. Be sure to install safety devices if output pressure above the set range can lead to damage or malfunction of equipment on the outlet side.. Residual pressure relief without inlet pressure. In cases where the inlet pressure has been released while the outlet pressure is in a low-pressure setting state, it may not be possible to exhaust the outlet pressure (residual pressure relief). Provide a residual pressure relief circuit if reliable outlet pressure relief must be performed.. When used with a closed downstream circuit and balance circuit. Please contact as there are cases in which the product cannot be used.. Read the instruction manual carefully. The product should be mounted and operated with a good understanding of its contents. Also, keep the manual where it can be easily referred to at any time.. Ensure space for maintenance. Ensure the necessary space for maintenance activities.. Strictly observe the tightening torque of the screw. Tighten the screw at the recommended torque in installation. Mounting Piping Precautions in use of One-touch fittings ) Tubing installation. Take a tubing with no flaws on its periphery and cut it off at a right angle. Use a TK-, or tubing cutter to cut the tubing. Do not use pinchers, nippers or scissors, etc. The tubing might be cut diagonally or flattened, making installation impossible or causing problems such as disconnection and leakage. Also, ensure sufficient tubing length.. Hold the tubing and push it in slowly, inserting it securely all the way into the fitting.. After inserting the tubing, pull it lightly to confirm that it will not come out. If the tubing is not inserted to the end, air leakage or disconnection may occur.. When piping, increase the length of the tubing to allow for any possible warping, increased tension or moment load, etc. to the fittings and tubing. ) Tubing removal. Push both the release bushing and flange.. Pull out the tubing while holding the release bushing so that it will not be locked again. Insufficient pressure on the release bushing will result in increased biting force that will impede the tubing removal.. When re-using a removable tubing, cut of the deformed part. If the deformed part of the tubing is used, it can cause air leakage or impede the tubing removal. In cases where a tubing brand other than is used, confirm that the tubing outside diameter accuracy satisfies the following specifications.. Nylon tubing ±0. mm or less. Soft nylon tubing ±0. mm or less. Polyurethane tubing +0. mm or less/ 0. mm or less Do not use the tubing if it does not satisfy the outside diameter accuracy. Tubing connection may be impossible or air leakage or tubing disconnection may occur after connection. Piping Air Supply. Use clean air. Do not use the regulator if the compressed air contains synthetic oil including chemicals or organic solvents, salt or corrosive gas. It may lead to damage or malfunction.. Install an air filter. Install an air filter on the inlet side in close proximity with the regulator. Select a type with µm or smaller filtration.. Install an after cooler, air dryer or mist separator (drain catch) to remove drainage. Compressed air containing excessive drainage may cause malfunction of the regulator, pressure switch or other pneumatic equipment.. If an excessive amount of carbon powder is generated, install a mist separator as a measure. If an excessive amount of carbon powder is generated from the compressor, it may adhere to the interior of the regulator and cause malfunction. Refer to Best Pneumatics Vol. for further details on compressed air quality. -- F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY PPA AL

45 Compact Manifold Regulator/Series ARM0/ Specific Product Precautions Be sure to read before handling. Operating Environment. Do not operate in locations having an atmosphere of corrosive gases, chemicals, sea water, fresh water or water vapor, or where there will be contact with the same.. In locations which receive direct sunlight, the sunlight should be blocked.. Do not operate in locations where vibration or impact occurs.. Do not operate in a location near a heat source or where radiated heat will be received. Adjustment Regulator. Set up the regulator while verifying the pressure that is indicated on the inlet side and outlet side pressure gauges. Turning the handle excessively could damage the internal parts.. The adjustment handle must be operated manually. Using a tool to turn the handle could lead to damage. Regulator. Set up the regulator after carefully verifying the pressure that is indicated on the inlet side pressure gauge.. Set the outlet pressure in a range that is within % of the inlet pressure. Also, it should not exceed the set pressure range.. Release the lock to adjust the pressure. After the adjustment, engage the lock. Failure to observe this procedure could damage the handle or cause the outlet pressure to fluctuate.. Turning the pressure adjustment handle clockwise increases the outlet pressure and turning it counterclockwise decreases the pressure. (To achieve the final set pressure, gradually increase from low pressure until the desired pressure is reached.) -- How to adjust indicator of the pressure gauge. Make sure to follow the instruction when opening the lens cover to adjust the pressure gauge.. Open the lens cover to the arrow s direction with finger nail. Adjustment OPE. Adjust the gauge needle with for example, a flat head screw driver. COVER. Close the lens cover to the arrow s direction until it snaps on. OP COVER COVER Maintenance To open the lens. To close the lens.. Maintenance should be performed according to the procedure indicated in the instruction manual. Improper handling can cause damage and malfunction of equipment and machinery.. Maintenance operations. Improper handling of compressed air is dangerous. Therefore, in addition to observing the product specifications, replacement of elements and other maintenance activities should be performed by personnel having sufficient knowledge and experience pertaining to pneumatic equipment.. Pre-maintenance inspection. When removing this product, turn off the electric power, and be certain to shut off the supply pressure and exhaust the compressed air in the system. Proceed only after confirming that all pressure has been released to the atmosphere.. Post maintenance inspection. After installation or repair, reconnect compressed air and electricity and conduct appropriate inspections to confirm proper operation. If there is an audible air leakage, or if the equipment does not operate properly, stop operation and confirm that the equipment is installed correctly.. Modification prohibited. Do not modify or reconstruct the unit.

46 Blocks/Series ARM0/ Specific Product Precautions Be sure to read before handling. Observe the proper screw tightening torque in installation. Tightening beyond the proper tightening torque may damage the mounting screws, blocks or switches. If the force is below the tightening torque range, the threaded joint can come loose.. Tightening torque for fixing screws and panel nuts of a single unit regulator. Tightening torque for regulator assembly fixing screws on regulator block. Tightening torque for blanking plates and pressure gauge fixing screws on regulator block 0.±0.0N m ±0.N m 0.±0.0N m 0.±0.0N m Handling One-touch fitting replacement For the ease of replacement, One-touch fittings are installed as the cassette type. One-touch fittings are retained with clips inserted from the directions illustrated blow. Remove the clips with a flat head screw driver to replace the One-touch fittings. When installing, insert each One-touch fitting deeply to the end and reinsert the clip to the specified position.. Single unit regulator. Regulator block. Various common supply blocks F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY PPA AL. Tightening torque for pressure switch fixing screws on common supply block with pressure switch and pressure switch block 0.±0.0N m. Tightening torque for D rail clamp screws on end block.±0.n m Pressure supply of -way valve common supply block Make sure that the handle is set at the OPEN or SHUT position in operation. The block cannot be used for the purpose of containing pressure because it allows a small amount of leakage. SHUT 90 OPEN --9

47 Pressure Switches/Series ARM0/ Specific Product Precautions Be sure to read before handling. Design & Selection. Operate the switch only within the specified voltage. Use of the switch outside the range of the specified voltage can cause malfunction and damage to the switch, it may also increase the risks of electrical shocks or fire.. Never apply a load above the maximum load capacity. It can damage the switch or shorten the service life.. Be sure to observe the set pressure range and maximum operating pressure. Use of the switch outside the set pressure range can cause failure and use beyond the maximum operating pressure can damage the switch.. Do not use the switch unless the equipment operates normally. After installation, repair or reform, connect air and electricity and conduct appropriate function and leakage tests to confirm proper installation.. Do not apply a tensile force to a cord. Be sure to hold the body to handle the product. Applying a tensile force to a cord may cause damage to the product.. Do not drop or bump the product. Dropping or bumping while handling may cause damage to the product. Mounting. Do not use the switch with corrosive gas or liquid. Do not use the switch with corrosive gas or liquid. Such gas or fluid may cause damage to the switch.. Do not use the switch at a vacuum pressure. If used in a vacuum pressure range, the switch will suction the outer air and become unable to operate. Pressure Supply Pressure Setting. The switching setting indication scale shows the set value for pressure decrease.. When the ON pressure signal is to be detected, the ON signal comes on at the pressure found by adding the hysteresis to the pressure set on the scale plate.. The pressure indication on the scale plate is provided as a guideline. Use a pressure gauge to measure the precise settings.. Connect the load Wiring Be sure to connect the load to the pressure switch before connecting the power supply.. Use a contact protection box. If the load driven by the pressure switch is an induction load or connected with a lead wire of m or longer, use a contact protection box in the following table. Contact protection box Operating voltage CD-P 00V AC CD-P V DC. Contact protection box internal circuit CD-P Surge absorber Zener diode. Contact protection box/connection method To connect the switch body and the contact protection box, connect the lead wire of the contact protection box on the side marked with SWITCH and the lead wire from the switch body. Connect the switch body and the contact protection box with a lead wire of m or shorter and arrange them as close as possible.. Lead wire dimensions Covering: ø. Insulator: ø. Conductor: ø0. Choke coil CD-P Choke coil Operating Environment Lead wire length Switch connection side: 0. m Load connection side: 0. m Brown lead wire Blue lead wire Brown lead wire Blue lead wire. Never use in the presence of explosive gases. These switches are not rated as explosion proof. Never use in the presence of an explosive gas as this may cause a serious explosion.. Do not use in an environment where a strong magnetic field is present. The influence of the external magnetic filed may cause the switch to malfunction.. Do not use in an environment where the switch is exposed to water or oil splashes. Because the switch has an open type construction, ingress of water or oil can corrode the electric circuit, resulting in malfunction and damage.. Do not apply vibration to the switch. If vibration is applied, malfunction or setting errors may result. --0

48 Series ARM0 How to Order Front handle type ARM0F 0 B Z. / piping position side side Bottom Top Bottom Top Top side side Top side Example of panel mounting side. / fitting type Metric size side side Straight Elbow Straight Elbow ø ø ø ø ø ø ø ø Bottom Inch size Bottom side side Straight Elbow Straight Elbow ø/ ø/ ø/ ø/ ø/ ø/ ø/ ø/ 9 0. Accessory B P B P PC Note ) None Note ) Bracket Note ) Pressure gauge Panel nut ( ) ( ) Display cover Note ) In case of a type with bracket, the panel nut is included. Note ) Pressure gauges are not available with the copper-free specification. Note ) Please note that the dimensions will be big when PC is required. Pressure gauge Panel nut Bracket Panel Display cover Display cover Panel nut --0

49 Regulator Single Unit Type Series ARM0. Option. Unit representation None 0. MPa Note ) setting Nonrelieving Note ) Oil-free Note ) A pressure gauge with a full span of 0. MPa is attached. Note ) The oil-free type has non-greased fluid contact areas. Specifications Model Regulator construction Working principal Standard Relief mechanism Optional Backflow function side tubing O.D. side tubing O.D. Proof pressure Maximum operating pressure Standard Set pressure range Optional Fluid Ambient and fluid temperature Weight Z Note) ARM0F Direct acting Diaphragm regulator Relief type Non-relieving type Within (unbalance type) ø, ø, ø/, ø/ ø, ø, ø/, ø/.mpa.0mpa 0.0 to 0.MPa 0.0 to 0.MPa (Low pressure type) Air to 0 C g Note) When the regulator is used with backflow regulator, operate at a set pressure of 0. MPa or above. Description Display unit for product name plate and pressure gauge: MPa Display unit for product name plate and pressure gauge: PSI Note) This product is for overseas use only according to the new Measurement Law. (The SI unit type is provided for use in Japan.) F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY PPA AL --

50 Series ARM0 Flow Characteristics ARM0F -0 ARM0-0 (One-touch fittings: / ø) ARM0F -0 ARM0-0 (One-touch fittings: ø, ø) ARM0F -0 ARM0-0 (One-touch fittings: / ø) Flow rate l/min(anr) Flow rate l/min(anr) Condition: Inlet pressure 0.MPa Condition: Inlet pressure 0.MPa Condition: Inlet pressure 0.MPa ARM0F -0- ARM0-0- (One-touch fittings: / ø) ARM0F -0- ARM0-0- (One-touch fittings: ø, ø) ARM0F -0- ARM0-0- (One-touch fittings: / ø) Condition: Inlet pressure 0.MPa Flow rate l/min(anr) Flow rate l/min(anr) Condition: Inlet pressure 0.MPa Condition: Inlet pressure 0.MPa Flow rate l/min(anr) Flow rate l/min(anr) Pressure Characteristics ARM0F -0 ARM Conditions: Inlet pressure 0.MPa Outlet pressure 0.MPa Flow rate 0l/min (ANR) ARM0F -0- ARM Conditions: Inlet pressure 0.MPa Outlet pressure 0.MPa Flow rate 0l/min (ANR) Set point Set point Inlet pressure MPa Inlet pressure MPa --

51 Regulator Single Unit Type Series ARM0 Construction ARM0 e ARM0F o w t i q ) y. - -, +. i o Component Parts No. Description Material r * u q / Replacement Parts No. Description Material w t e y ) r, * + u / Part no. F.R.L. AV AU AF AR IR VEX q w e r t y u i Body Bonnet Handle Valve seat Adjusting screw assembly Adjustment spring Regulator clip Blanking plate assembly PBT PBT POM POM Reinforced steel Steel wire Stainless steel ) * +, -. / Diaphragm assembly Valve Valve spring O-ring O-ring O-ring Fitting assembly Weatherproof NBR, POM HNBR, Aluminum alloy Stainless steel NBR NBR NBR A -0 Refer to page --. AMR ITV IC VBA o Square nut Steel VE Dimensions VY ARM0-0 0 ø PPA AL PUSH LOCK Panel cutout dimensions For dimensions and accessories of One-touch fittings, please refer to page --. (Max.) Plate thickness: Max Through hole for M ø

52 Series ARM0 Dimensions ARM0F- 0 0 Panel cutout dimensions -R or less to. ø ø0 Plate thickness: Max.. (Max.) ARM0F- 0PC 0PC Panel cutout dimensions -R or less Through hole for M ø. PUSH LOC K to. ø ø0 0 Plate thickness: Max.. OPEN MPa PUS H LOC K (Max.) --

53 Regulator/Single Unit Type Option Pressure auge Part no. C-A-X0 C-0A-X0 C-PA-X0 C-P0A-X0 Specifications Fluid Ambient and fluid temperature Display accuracy Calibration angle Limit indicator Weight OPEN Panel Nut V CO ER Part no. Material POM Weight g Pressure gauge indication range Indication unit 0 to 0.MPa MPa 0 to.0mpa 0 to 0PSI PSI 0 to 0PSI Air - to 0 C ±%F.S. (Full Span) 0 With limit indicator g.. ø. One-touch Fittings for Regulator VVQ000-0A One-touch fittings for regulator C C N N ARM0 Straight type Elbow type X X. Straight type Elbow type X ARM0F X 0. Y L Fitting size Fitting type ø ø ø/ ø/ Straight Elbow X Fitting size ø, ø/ ø ø/ Fitting size ø, ø/ ø ø/ Fitting size ø, ø/ ø ø/ Fitting size ø, ø/ ø ø/ C Option None Oil-free X X... X X Y.. Y.. F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY PPA AL (Width across flats of equilateral octagon). Bracket Y ø. Part no. Material Weight Nickel plated steel g. Display Cover R. ø Part no. Material Weight PBT 0.g (R) --

54 Series ARM0F Made to Order Specifications: Please contact regarding detailed specifications, dimensions and delivery. Specifications Regulator single unit front handle type/ For manifold Regulator construction Direct acting Working principal Diaphragm regulator Standard Relief type Relief mechanism Optional Non-relieving type Backflow function Within (Unbalance type) / air passage diameter ø / gasket sealing O.D. ø Proof pressure.mpa Maximum operating pressure.0mpa Standard 0.0 to 0.MPa Set pressure range Optional 0.0 to 0.MPa (Low pressure type) Fluid Air Ambient and fluid temperature to 0 C Weight g Note ) Mounting bolts and O-rings ( of each) are attached. Note ) When the regulator is used with backflow, operate at a set pressure of 0. MPa or above. How to Order ARM0F A. Accessory Z X0 For manifold. Option Example A. Unit representation Dimensions Without pressure gauge With pressure gauge Description Display unit for product name plate and pressure gauge: MPa Z Note) Display unit for product name plate and pressure gauge: PSI Note) This product is for overseas use only according to the new Measurement Law. (The SI unit type is provided for use in Japan.) None 0. MPa Note ) setting Nonrelieving Note ) Oil-free Note ) A pressure gauge with a full span of 0. MPa is attached. Note ) The oil-free type has non-greased fluid contact areas. Need to prepare manifold base. (Max.0) ø0 PU SH LO C K Holding screw M x 0. x 0 O-ring size ø x.w 9 --

Direct Operated Precision Regulator Modular Style. Standard Specifications

Direct Operated Precision Regulator Modular Style. Standard Specifications 1 Direct Operated Precision Regulator Modular Style Series P3 Courtesy of Steven Engineering, Inc.-23 Ryan Way, South San Francisco, CA 948-637-Main Office: (65) 588-92-Outside Local Area: (8) 258-92-www.stevenengineering.com

More information

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut Regulator for 2 MPa RX 2 How to Order RX2 1 Regulator 1 Regulating pressure.5 to.85mpa {.51 to 8.7kgf/cm²}.5 to.3mpa {.51 to 3.1kgf/cm²} Thread type Nil N F Rc(PT) NPT (PF) Port size 1 2 ccessories/options

More information

Standard Specifications

Standard Specifications NARM, 2 Ways of Connection Small Size Pressure Gauge ø5mm Reverse flow function available on the standard model Space Saving -B2 NARM-6A-NG Standard Specifications Fluid Proof pressure psig (MPa) Max.

More information

Regulator/Modular Style AR1000 to 6000

Regulator/Modular Style AR1000 to 6000 Regulator/Modular Style AR000 to 6000 Can be combined with a modular style air filter and lubricator A rich variety of models enables precise and stable pressure settings to meet user needs Drain cock

More information

Pilot Check Valve: Metal Body Type

Pilot Check Valve: Metal Body Type INFORMATION Pilot Check Valve: Metal Body Type The use of a metal body improves strength and environmental resistance. Temporary intermediate stops are possible. *1 *1 Precise intermediate stops are not

More information

How to Order RM0 0 Z. IN/OUT fitting type Metric size Inch size Straight Elbow Straight Elbow Straight Elbow Straight Elbow ø ø ø ø ø ø ø ø ø/ ø/ ø/ ø

How to Order RM0 0 Z. IN/OUT fitting type Metric size Inch size Straight Elbow Straight Elbow Straight Elbow Straight Elbow ø ø ø ø ø ø ø ø ø/ ø/ ø/ ø Series RM/ End lock RME Port Plug End block End block type Mounting position L Left side R Right side L side end block 0. L VVQ0000 Single unit regulator / Port plug for regulator block ø0 0 Options Note

More information

Series AS-FPQ/AS-FPG. Speed Controller with One-touch Fitting for Clean Room. Speed controllers for clean room use

Series AS-FPQ/AS-FPG. Speed Controller with One-touch Fitting for Clean Room. Speed controllers for clean room use CAT.ES20-19 A Speed Controller with One-touch Fitting for Clean Room Series AS-FPQ/AS-FPG Series AS-FPG Series AS-FPQ Speed controllers for clean room use AS-FPQ: Brass (electroless nickel plated) and

More information

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100 Clean Air Filter Variations SFD SFD SFD SFD Made to Order Type Disposable (non-replaceable element) Cartridge (replaceable element) Flow rate L/min (ANR) (at inlet pressure.7 MPa) Up to 6 Up to 8 Up to

More information

Series IRV1000/2000/3000

Series IRV1000/2000/3000 CAT.ES60-16 A Regulator Series /2000/3000 Allows adjustment of vacuum line pressure Regulator Series /2000/3000 3 sizes offered in the series Variations have been expanded to three sizes from only one

More information

Related Products: Auto Drain Valve. Model/Specifications. Model

Related Products: Auto Drain Valve. Model/Specifications. Model Related Products: Auto Drain Valve /600 Drainage is automatically discharged in a reliable manner, without requiring human operators. Highly resistant to dust and corrosion, operates reliably, and a bowl

More information

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications Outstanding performance in extremely low pressure and low pressure ranges from 0.003 to. Realizing high performance, energy saving, and compact size. Realize precise pressure control in a pressure range

More information

Hand Valve Series. Push-In Fitting Type Shut-off Valve (Residual Pressure Release Valve) Control Open/Close for Air Supply.

Hand Valve Series. Push-In Fitting Type Shut-off Valve (Residual Pressure Release Valve) Control Open/Close for Air Supply. http://www.pisco.co.jp VALVE TUBE MAKE-TO-ORDER PRODUCTS Push-In Fitting Type Shut-off Valve (Residual Pressure Release Valve) Hand Valve Series 556 Control Open/Close for Air Supply. Release Residual

More information

Power Valve: Precision Regulator. High precision, large capacity relief regulator

Power Valve: Precision Regulator. High precision, large capacity relief regulator Power Valve: Precision Regulator Series VEX High precision, large capacity relief regulator port large exhaust capacity pressure reducing valve which utilizes a nozzle flapper mechanism available as air

More information

Modular Type Regulators

Modular Type Regulators Modular Type Regulators Series AR AC Regulator Series AR Port size Options AFARAL, 1/4 Bracket AFAR AWAL AR4-A, 1/2 Round type pressure gauge With set nut (for panel mount) AFAFMAR P.45 to 5 AR4-6-A ot

More information

Coiling Tube with Twist-Proof Fitting

Coiling Tube with Twist-Proof Fitting http://www.pisco.co.jp FITTING CONTROLLER VALVE TUBE MAKE-TO-ORDER PRODUCTS Push-In Fitting Type Anti-Twisting Coiling Tube for Air Tool Coiling Tube with Twist-Proof Fitting 306 Avoid Twisted Tube Problem

More information

Compact Regulator. ARX20 Series. 2.0 MPa compatible, piston type compact regulator ARJ

Compact Regulator. ARX20 Series. 2.0 MPa compatible, piston type compact regulator ARJ Compact Regulator 2 Series 2. MPa compatible, piston type compact regulator V SR X AP1 Compatible with inlet supply pressure of 2. MPa Employs a knob shape for easy operation Compact type (face to face

More information

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K Modular Type Regulator Series R Regulator Series R Model R M5 x.8 ccessory R2 /8, /4 R /4, 3/8 R3 /4, 3/8 R4 /4, 3/8, /2 Pages 36 through 4 Regulator with back flow mechanism Series RK R4-6 R5 R6 R2K RK

More information

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K Modular Type Regulator Series R Regulator Series R Model R M5 x.8 ccessory R2 /8, /4 R /4, 3/8 R3 /4, 3/8 R4 /4, 3/8, /2 Pages 36 through 4 Regulator with back flow mechanism Series RK R4-6 R5 R6 R2K RK,

More information

VACUUM REGULATORS CONTENTS

VACUUM REGULATORS CONTENTS CAD drawing data catalog is available. ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Small Regulators Features 759 Specifications, Order Codes, Flow Rate

More information

Change Valve. Push-In Fitting Type Three-way Changeover Valve. Changeover Air Direction by 90. Lightweight and Compact Design.

Change Valve. Push-In Fitting Type Three-way Changeover Valve. Changeover Air Direction by 90. Lightweight and Compact Design. http://www.pisco.co.jp VALVE TUBE MAKE-TO-ORDER PRODUCTS Push-In Fitting Type Three-way Changeover Valve Change Valve Changeover Air Direction by 90 Lightweight and Compact Design. Fine Operability and

More information

Compact Manometer. Pressure measurements can easily be taken any time, anywhere.

Compact Manometer. Pressure measurements can easily be taken any time, anywhere. 1 Compact Manometer Series PPA Pressure measurements can easily be taken any time, anywhere. Compact and lightweight Portable type with a lightweight of only about 100 g (unit 50 g, battery 50 g) can also

More information

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A Air Consumption 70% Down New Product Precision Regulator Air Saving Type RPE Series PRECISION REGULATOR RPE SERIES Large Air Saving CC-1072A Air Consumption 70% Down. New Type Eco-friendly Precision Regulator

More information

Precision Regulator. IR1000/2000/3000 Series ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV IC ITVH ITVX PVQ VY1 AP100.

Precision Regulator. IR1000/2000/3000 Series ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV IC ITVH ITVX PVQ VY1 AP100. Precision Regulator //3 Series Basic Type Air Operated Type Series Model Set pressure range Port size Page Series Series 3 Series 3 3 3 Series 3 Series 3.5 to MPa. to MPa. to.8 MPa /8 8.5 to MPa. to MPa.

More information

Precision Regulator. Series Model Regulating pressure range Port size Page

Precision Regulator. Series Model Regulating pressure range Port size Page Precision Regulator Series // Basic Type Air Operated Type Series Model Regulating pressure range Page Series Series Series Series Series.5 to MPa. to MPa. to.8 MPa /8 55.5 to MPa. to MPa /4 55. to.8 MPa.

More information

Push-In Fitting Type Pressure Gauge

Push-In Fitting Type Pressure Gauge http://www.pisco.co.jp CONTROLLER VALVE TUBE MAKE-TO-ORDER PRODUCTS Push-In Fitting Type 526 Compact Design. Pressure Indication by Tube Insertion into Push-In Fitting. Check Valve Silencer Controller

More information

Vacuum Regulator. IRV10/20 Series. Weight reduced by. RoHS ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV

Vacuum Regulator. IRV10/20 Series. Weight reduced by. RoHS ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV Vacuum egulator IV0/ eries oh AJ A45 ingle ided Connections eries AX For ease of installation and panel mounting AM AM Integrated digital pressure switch for panel mounting I -A I (Made to Order) ingle

More information

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly. Components preparation and pressure adjustment ABP Overview ABP is a component that enables boosting by s only up to twice primary pressure (.0MPa max.) in combination with using air tank but not using

More information

Booster Regulator/Air Tank

Booster Regulator/Air Tank Booster Regulator/Air Tank Increase factory air pressure by up to 4 times! Air-only operation requires no power supply, reduces heat generation, and Boost pressure allows easy installation. NEW Renewed

More information

Push-In Fitting Type Silencer

Push-In Fitting Type Silencer http://www.pisco.co.jp CONTROLLER VALVE TUBE MAKE-TO-ORDER PRODUCTS Push-In Fitting Type 540 Reduce Exhaust Noise from Exhaust Port. Excellent Silencing Effect. Selection from 3 types. Push-In Fitting

More information

Push-In Fitting Type with Stop Valve

Push-In Fitting Type with Stop Valve http://www.pisco.co.jp Push-In Fitting Type with Stop Valve 278 Push-In Fitting Type with Stop Valve for General Pneumatic Piping. Air Stop by Tube Disconnection. Easy Insertion and Disconnection by Double-passage

More information

(1) Type (2) Thread size (T) (3) Wrench size specification : inch spec. (NPT, UNF) : mm spec. (M, R)

(1) Type (2) Thread size (T) (3) Wrench size specification : inch spec. (NPT, UNF) : mm spec. (M, R) This exhaust needle valve, which comes with silencer, controls the exhaust flow rate. The valve can be attached directly to a solenoid valve where a cylinder or like mechanism has no sufficient space around

More information

Flow Characteristics NAR1 NAR 9 6 M5X.8 NAR2 NPT 3/ Flow (scfm) NAR5 NPT 3/ Flow (scfm) Flow (

Flow Characteristics NAR1 NAR 9 6 M5X.8 NAR2 NPT 3/ Flow (scfm) NAR5 NPT 3/ Flow (scfm) Flow ( How To Order NAR 1, 2, 25,, 4, 5, 6 Regulator Body size 1 M5 2 1/8 25 1/4 3/8 4 1/2 5 3/4 6 1 NAR N 3 BG 1N Port Thread Nil Rc(PT) F G(PF) N NPT Accessories and Combinations Accessory Suffix 1 4 N R Port

More information

Series AMJ. Drain Separator for Vacuum

Series AMJ. Drain Separator for Vacuum CAT.E 827- Drain Separator for Vacuum Remove water droplets from air by simply installing in vacuum equipment connection lines. Effective for removing water droplets from the air sucked into vacuum pumps

More information

COMMON PRECAUTIONS Data Sheet - Be Sure To Read Before Handling Page 1 of 6

COMMON PRECAUTIONS Data Sheet - Be Sure To Read Before Handling Page 1 of 6 COMMON PRECAUTIONS Page 1 of 6 These safety instructions are intended to prevent a hazardous situation and/or equipment damage. These instructions indicate the level of potential hazard by labels of "Caution",

More information

Insert Ring. Protection Ring from Tube Deformation. Protect tubes from deformation. Ultra soft tube is connectable to Fitting.

Insert Ring. Protection Ring from Tube Deformation. Protect tubes from deformation. Ultra soft tube is connectable to Fitting. http://www.pisco.co.jp TUBE MAKE-TO-ORDER PRODUCTS Protection Ring from Deformation Insert Ring 668 Protect tubes from deformation. Ultra soft tube is connectable to Fitting. Necessary for the connection

More information

Cautions : 1. Clogging of the element raises resistance to exhaust, thus lowering the

Cautions : 1. Clogging of the element raises resistance to exhaust, thus lowering the The Silencer, connected to the exhaust port of a device, suppresses the exhaust noise. The Silencer displays an excellent noise suppression effect. Three types are available for your selection. The element

More information

Pressure Gauge Series

Pressure Gauge Series Pressure Gauge Series Compact Design. Connection type In line Plug in Panel mount Threaded Model Designation (Example) GP C 15 U10 U 1 Type Pressure Gauge 1 Type 2 Series 4 Wrench size 3 Thread size/ Tube

More information

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators Supply Pressure Regulator Type 4708 Type 4708-5352 on Type 3730 Positioner Type 4708-52 with filter receptacle Type 4708-6252 on Type 3372 ctuator Fig. Supply pressure regulators Mounting and Operating

More information

Specifications. Construction. 2 port valve/series VHK2 3 port valve/series VHK3. Component Parts. Standard style. Flame resistant style

Specifications. Construction. 2 port valve/series VHK2 3 port valve/series VHK3. Component Parts. Standard style. Flame resistant style Finger Valve SeriesVHK Large effective area: to mm 2 Small knob operating force: 0.43 to 1.4 kgfcm Poppet valve construction with few seal defects The series begins with the min. tube O.D. of. Selection

More information

IR1000-A IR1010-A IR1020-A

IR1000-A IR1010-A IR1020-A Document No. IR -OMT0020 PRODUCT NAME Precision Regulator MODEL / Series / Product Number IR1000-A IR1010-A IR1020-A Contents Safety Instructions 1 to 5 1. Application 6 2. Specifications 6 3. Construction

More information

Cautions : 1. Be careful when you release the Stop Fitting with some internal pressure

Cautions : 1. Be careful when you release the Stop Fitting with some internal pressure The flow-shut mechanism will operate to stop the air flow when the tube is disconnected and will allow air flow when the tube is connected. The double-passage structure facilitates easy connection and

More information

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9 Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Fluid Proof pressure Operating pressure differential range (Difference between tank pressure and line pressure) Vibration resistance

More information

Air Saving Valve. Pressure Valve Flow Valve

Air Saving Valve. Pressure Valve Flow Valve Air Saving Valve Series Series Pressure Valve Flow Valve % reduction in air consumption Cuts air consumption by operating the return stroke at a reduced pressure. valve Pressure Air consumption reduction

More information

Tube Cutter with Measuring tape built-in

Tube Cutter with Measuring tape built-in http://www.pisco.co.jp TUBE MAKE-TO-ORDER PRODUCTS Cutter with Measuring tape built-in 658 Series Cutter TUBE VALVE CONTROLLER FITTING Model Code of Cutter (Example) Cutter Model Code of Cutter Blade (Example)

More information

Series ZFC. Air Suction Filter In-line Type with One-touch Fittings

Series ZFC. Air Suction Filter In-line Type with One-touch Fittings CAT.E832- A Air Suction Filter In-line Type with One-touch Fittings Series ZFC An in-line type air suction filter that prevents trouble in vacuum equipment due to contaminants in the air IN/OUT straight

More information

Recommended applicable tubing. Specifications. Operating vacuum pressure. 20 C to 80 C Threads. Principal parts material

Recommended applicable tubing. Specifications. Operating vacuum pressure. 20 C to 80 C Threads. Principal parts material Series K Clean one-touch fittings For blowing Recommended applicable olyolefin: Series T Tubing material Soft polyolefin: Series TS Tubing O.D. ø, ø, ø, ø, ø olyurethane Series TU, Nylon Series T, and

More information

Pressure Relief 3 Port Valve New. Sonic Conductance 45% With the indicator window Step1. With locking holes

Pressure Relief 3 Port Valve New. Sonic Conductance 45% With the indicator window Step1. With locking holes Conforming to OSHA Standard Pressure Relief Port Valve New RoHS with Locking Holes Weight Max. 60% Lighter Sonic Conductance 5% C[dm/s bar] VHS0 Max. Energy Saving Up Safety Measure Zero blow-by of the

More information

Air Saving Valve. Series ASQ. Series ASR. Pressure Valve. Flow valve TMH ASD AS AS-FG AS-FP AS-FM ASP ASN AQ ASV AK VCHC ASS. r r AS-FE KE 10 0.

Air Saving Valve. Series ASQ. Series ASR. Pressure Valve. Flow valve TMH ASD AS AS-FG AS-FP AS-FM ASP ASN AQ ASV AK VCHC ASS. r r AS-FE KE 10 0. Air Saving Valve Series R Pressure Valve Series Q Flow Valve P r.9.7 2..3.1 D -FE KE -FG -FP -FM.1.2.2.3 pressure (MPa) -D -T P ow valve Fl N AQ V e n by o i t p nsum n stroke o c r i r a Cuts g the retu

More information

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves. Powers Controls RV 201 Pressure Reducing Valves Description Features Product Numbers Dual Pressure PRV Technical Instructions Document No. 155-049P25 RV 201-1 Single Pressure PRV The RV 201 Pressure Reducing

More information

Compact Manometer. Pressure measurements can easily be taken any time, anywhere. POWER LIGHT

Compact Manometer. Pressure measurements can easily be taken any time, anywhere. POWER LIGHT Compact Manometer Series PPA Pressure measurements can easily be taken any time, anywhere. G GS PPA Compact and lightweight Portable type with a lightweight of only about 100 g (unit 50 g, battery 50 g)

More information

(1) Type (2) Cylinder dia. (3) Gripper action : Single-acting closing gripper (normally open) (4) Holder type

(1) Type (2) Cylinder dia. (3) Gripper action : Single-acting closing gripper (normally open) (4) Holder type These are air finger models featuring light weight and miniature size. Blank fingers are available for the K type fingers as option. R-guide leaves no possibility of misalignment. The blank finger can

More information

Filter-Regulator-Lubricator

Filter-Regulator-Lubricator Filter-Regulator-Lubricator 1/2" NPT Inlet/Outlet Ports PD16.19 July, 2016 Machine Parts & Operating Instructions Save This Document and Educate All Personnel WARNING Always follow the safety instructions

More information

How to Order. Rc NPT 1/8 1/4 3/8 1/2

How to Order. Rc NPT 1/8 1/4 3/8 1/2 AWM 3 AWD 3 Mist Separator Regulator AWM2 to AWM4 Micro Mist Separator Regulator AWD2 to AWD4 3 E 3 E How to Order Mist Separator Regulator 1 2 Micro Mist Separator Regulator The AWM series is made up

More information

Pressure Dump Valve Service Kit for Series 2300 Units

Pressure Dump Valve Service Kit for Series 2300 Units Instruction Sheet Pressure Dump Valve Service Kit for Series 00 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00 applicator tanks when the unit

More information

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION INSTALLATION INSTRUCTIONS CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION The CVS Controls 67CFR Filter regulator is a pressure reducing supply regulator typically used for pneumatic

More information

ALF400 to 900, ALT-5/-9

ALF400 to 900, ALT-5/-9 Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Auto feed lube 00 00-0 00 00 00 900 - --IS- -9 AIR : OIL : Fluid Proof pressure Air. MPa 0. MPa.0 MPa (Note ) Operating pressure differential

More information

Regulator: Modular Type with Back flow Mechanism. AR30K to 60K. Body size. Port size 1/4 3/8 1/2 3/4 AR40 AR50 3/4 1/2

Regulator: Modular Type with Back flow Mechanism. AR30K to 60K. Body size. Port size 1/4 3/8 1/2 3/4 AR40 AR50 3/4 1/2 Regulator: Modular Type with ack flow Mechanism R3 to 6 How to Order Regulator with a built-in mechanism that ensures a quick release of the outlet air pressure (built-in check valve with back flow mechanism).

More information

Cautions : 1. The gauge orientation on the GPU and GPM types can be changed by using

Cautions : 1. The gauge orientation on the GPU and GPM types can be changed by using The compact-size pressure gauge can be installed in small spaces. With the built-in tube fitting type, tube connection is the only necessary step before pressure indication. Fluid medium Indicated pressure

More information

INSTALLATION & MAINTENANCE INSTRUCTIONS

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION / IDENTIFICATION The QBX series valve uses Proportion-Air closed loop technology for Pressure control. It gives an output pressure proportional to an electrical command signal input. The QB1X

More information

Section 3- Repair and Calibration Procedures

Section 3- Repair and Calibration Procedures Section 3- Repair and Calibration Procedures 1. Refrigerant Removal Procedures 2. Scale/PC Board Recalibration Procedure 3. PC Board Configuration Procedure of AR400 4. Scale Tare Procedure 5. Gauge Calibration

More information

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity Type 4708-45 Supply Pressure Regulator with increased air capacity Translation of original instructions Mounting and Operating Instructions EB 8546-1 EN Edition March 2016 Note on these mounting and operating

More information

Speed Controller Anti-spatter Series

Speed Controller Anti-spatter Series http://www.pisco.co.jp CONTROLLER VALVE TUBE MAKE-TO-ORDER PRODUCTS Push-In Fitting Type Flame-Retardant Spatter-proof 422 Adopting Flame-Retardant Resin (V-). Protective Cover to Protect from Sparks.

More information

Air Saving Valve reduction in 40% air consumption 40% air consumption Air consumption reduction ratio (%) Flow valve Flow valv

Air Saving Valve reduction in 40% air consumption 40% air consumption Air consumption reduction ratio (%) Flow valve Flow valv CAT.ES-173 A Air Saving Valve % reduction in air consumption Cuts air consumption by operating the return stroke at a reduced pressure. valve Pressure Air consumption reduction ratio (%) 3 1.1.1...3 pressure

More information

The plastic bowl guard does not corrode. The draining method is selectable between the push type and the auto drain type.

The plastic bowl guard does not corrode. The draining method is selectable between the push type and the auto drain type. he plastic bowl guard does not corrode. he draining method is selectable between the push type and the auto drain type. he air filter is designed for draining and removal of foreign matter. (Element: 5µm)

More information

Ball Valve Series. Push-In Fitting Type Shut-off Valve. Control Open/Close Air Supply. Ensure Effective Area for Variety of Tube Dia.

Ball Valve Series. Push-In Fitting Type Shut-off Valve. Control Open/Close Air Supply. Ensure Effective Area for Variety of Tube Dia. http://www.pisco.co.jp VALVE TUBE MAKE-TO-ORDER PRODUTS Push-In Fitting Type Shut-off Valve Ball Valve Series 564 ontrol Open/lose Air Supply. Ensure Effective Area for Variety of Tube Dia. Easily Adjustable

More information

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN Type 4708-45 Pressure Regulator for increased air capacity Fig. 1: Type 4708-45 Pressure Regulator Mounting and Operating Instructions EB 8546-1 EN Edition March 2010 Definition of the signal words used

More information

Filter-Regulator-Lubricator

Filter-Regulator-Lubricator Models: 10671-1/2" NPT Filter 10673-1/2" NPT Regulator 10675-1/2" NPT Lubricator 10677-1/2" NPT Filter-Regulator 10679-1/2" NPT Regulator-Lubricator 10681-1/2" NPT Filter-Regulator-Lubricator Parts Page

More information

Clean Speed Controller with One-touch Fitting

Clean Speed Controller with One-touch Fitting Clean Speed Controller with One-touch Fitting Series -FPQ/-FPG -FPG Series -FPQ Series Speed controllers for clean room use S R -FPQ: (electroless nickel plated) and -FPG: are now available as a series.

More information

Suitable for Semi-Conductor, Measuring Instrument, Printing and Medical Industries

Suitable for Semi-Conductor, Measuring Instrument, Printing and Medical Industries http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Suitable for Semi-Conductor, Measuring Instrument, Printing and Medical Industries 182 Filtering Accuracy:.1μm, Correcting

More information

(1) Name of tube (2) Tube dia. (O.D./I.D.) (3) Tube length. (4) Tube color. Model UD0425. UD1290 O.D. I.D. (mm) UD1075 UD0860 UD

(1) Name of tube (2) Tube dia. (O.D./I.D.) (3) Tube length. (4) Tube color. Model UD0425. UD1290 O.D. I.D. (mm) UD1075 UD0860 UD The polyurethane tube, featuring excellent flexiblity, helps compact piping requiring small bending radius. The useful cut marks at 500mm interval are printed on the tube. Model UD0425 UD0640 UD0860 UD1075

More information

Mounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type

Mounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type Type 4708 Supply Pressure Regulators Translation of original instructions Type 4708-53 Type 4708-64 Type 4708-12 Mounting and Operating Instructions Edition March 2018 Note on these mounting and operating

More information

3/8" Dr. Air Butterfly Impact Wrench

3/8 Dr. Air Butterfly Impact Wrench 8192106 3/8" Dr. Air Butterfly Impact Wrench Owner s Manual Read and understand all instructions before use. Retain this manual for future reference. Specifications Construction: Polished aluminum and

More information

Clean Regulator/Fluororesin Type

Clean Regulator/Fluororesin Type Clean egulator/fluororesin Type Series Washing/ssembly Procedure Washing parts: ody, Valve diaphragm and Diaphragm Parts Degreasing washing DI water washing lcohol washing ssembly Inspection Wetted part

More information

Speed Controller Constant Flow

Speed Controller Constant Flow http://www.pisco.co.jp CONTROLLER VALVE TUBE MAKE-TO-ORDER PRODUCTS Push-In Fitting Type Speed Control Valve for Fixed Flow Rate Speed Controller 440 Adjust Actuator Speed. Suitable for Mass Production

More information

(1) Type. (2) Tube dia. (ød) : ø8mm (ø5/16in.) (3) Thread size (T) (4) Specification. Fluid medium. Air, water * 1, * 2, * 3 Max. operating pressure

(1) Type. (2) Tube dia. (ød) : ø8mm (ø5/16in.) (3) Thread size (T) (4) Specification. Fluid medium. Air, water * 1, * 2, * 3 Max. operating pressure This type of tube fitting comes in eight lengths to suit your applications. The tube fitting, provided with a hexagonal hole, can be easily installed using an Allen wrench, even in a narrow or limited

More information

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION The QB3 is a closed loop pressure regulator consisting of two solenoid valves, internal pressure transducer, and electronic controls mounted to an integrated

More information

Related products. Components for air preparation and pressure adjustment / F.R.L. unit. Pressure gauge. Indidcator

Related products. Components for air preparation and pressure adjustment / F.R.L. unit. Pressure gauge. Indidcator Related products Pressure gauge / indicator omponents preparation and pressure adjustment / unit Refrigerating ir uto. drain ir Pressure gauge ONTENTS Pressure gauge assembly (G401-W) 660 With safety mark

More information

Operation Manual Air Saver Unit ASV5000 Series

Operation Manual Air Saver Unit ASV5000 Series 9IM-V066-b Operation Manual Air Saver Unit ASV5000 Series Thank you for your choice of Kuroda Pneumatics LTDs product on this time. Please read this operation manual carefully and use the product correctly.

More information

OWNER S TECHNICAL MANUAL

OWNER S TECHNICAL MANUAL EL SERIES OWNER S TECHNICAL MANUAL DP7002 1 Air Operated Diaphragm Pump Description The DP7002 1 air operated diaphragm pump is the ideal device for the pumping, transfer and dispensing of chemical liquids,

More information

Pressure Dump Valve Service Kit for Series 3000 Units

Pressure Dump Valve Service Kit for Series 3000 Units Instruction Sheet Pressure Dump Valve Service Kit for Series 000 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00, 400, 500, and 700 applicator

More information

Specifications. Construction. 2 port valve/series VHK2 3 port valve/series VHK3. Component Parts. Standard style. Standard style

Specifications. Construction. 2 port valve/series VHK2 3 port valve/series VHK3. Component Parts. Standard style. Standard style Finger Valve eriesvhk Large effective area: to mm 2 mall knob operating force: 0.43 to 1.4 kgfcm Poppet valve construction with few seal defects The series begins with the min. tube O.D. of. election from

More information

Regulator. Accessory. Description. Symbol. Nil. With bracket. B With round. Port size. (Without limit indicator) With set nut (For panel mount)

Regulator. Accessory. Description. Symbol. Nil. With bracket. B With round. Port size. (Without limit indicator) With set nut (For panel mount) eries R 2- ow to Order opper, fluorine and silicon-free + Low particle generation il hread type Rc 0 R 03 2 R 03 ody size / ith bracket Round pressure ith set nut tandard specifications odel luid roof

More information

Operating Manual. R280 Pressure regulator made of brass. 1. Intended Use

Operating Manual. R280 Pressure regulator made of brass. 1. Intended Use Pressure regulator made of brass Operating Manual 1. Intended Use Line or outlet pressure regulators- /reducer for Air, gases and liquids which is designed to effect reduction to a downstream pressure

More information

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1. 2 GALLON TWIN STACK AIR COMPRESSOR Model: 9526 DO NOT RETURN TO STORE. Please CALL 800-348-5004 for parts and service. CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or

More information

Tube for Clean Environment Polyurethane Tube Clean-Room Package

Tube for Clean Environment Polyurethane Tube Clean-Room Package http://www.pisco.co.jp TUBE MAKE-TO-ORDER PRODUCTS for Clean Environment Polyurethane Clean-Room Package 642 Fine Flexibility. Suitable for Small Bending Radius in General Pneumatic Piping. Cleaned and

More information

(2) Effective sectional area (no code for mini type) (3) Intake-side shape (no code for mini type) : Quick-fitting joint type : Taper pipe thread type

(2) Effective sectional area (no code for mini type) (3) Intake-side shape (no code for mini type) : Quick-fitting joint type : Taper pipe thread type In response to high-speed drive cylinder. The Quick Exhaust Valve comes with a built-in Quick Fitting. The Valve serves also as a shuttle valve. The exhaust port, having a throttling function, enables

More information

Anti-spatter Tube. Spatter-Proof Tube for Pneumatic Piping. Polyamide type Tube Coated with Flame-Retardant Resin(Equivalent to V-0 )

Anti-spatter Tube. Spatter-Proof Tube for Pneumatic Piping. Polyamide type Tube Coated with Flame-Retardant Resin(Equivalent to V-0 ) http://www.pisco.co.jp TUBE MAKE-TO-ORDER PRODUCTS Spatter-Proof for Pneumatic Piping Anti-spatter 646 Spark Resistance Polyamide type Coated with Flame-Retardant Resin(Equivalent to V-0 ) UL94 V-0 UL94

More information

Model GPR Primary Pressure Regulating Valve. Instruction Manual

Model GPR Primary Pressure Regulating Valve. Instruction Manual Model GPR-2000 Primary Pressure Regulating Valve Instruction Manual Please read this instruction manual thoroughly before using the primary pressure regulating valve, so that you may do so correctly and

More information

Low torque Metal seal type Rotary joint

Low torque Metal seal type Rotary joint CAT.E0- A Low torque Metal seal type Rotary joint Long Life 0. to billion rotations Under SMC s life test conditions. Flexible Coupling Fixed (Body) Low rotational torque 0.00 to 0.0 N.m or less Rotary

More information

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator. RS(H)10,15 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to

More information

Polyurethane Tube. Straight Tube for General Pneumatic Piping. Excellent in Flexibility. Suitable for Compact Piping Requiring Small Bending Radius

Polyurethane Tube. Straight Tube for General Pneumatic Piping. Excellent in Flexibility. Suitable for Compact Piping Requiring Small Bending Radius http://www.pisco.co.jp TUBE MAKE-TO-ORDER PRODUCTS Straight for General Pneumatic Piping Polyurethane 596 Standard Excellent in Flexibility Suitable for Compact Piping Requiring Small Bending Radius Variety

More information

Description Supply pressure Pressure range Connection Device Page max. bar bar thread

Description Supply pressure Pressure range Connection Device Page max. bar bar thread Pressure Regulators Supply pressure Pressure range onnection Device Page max. bar bar thread Maxi -Series, robust, interlockable 1 0. 1.8 / 17 G¼ - G1 R0, R1.0 made of plastic, also for liquids 1,5 0 4

More information

RIX COMPRESSORS. MICROBOOST Owner s Manual CONFIGURATION A MB-115 MB-230. November 21, 2002 APPLICABILITY [ A]

RIX COMPRESSORS. MICROBOOST Owner s Manual CONFIGURATION A MB-115 MB-230. November 21, 2002 APPLICABILITY [ A] RIX COMPRESSORS MICROBOOST Owner s Manual CONFIGURATION A MB-115 MB-230 November 21, 2002 APPLICABILITY [ A] INTRODUCTION Safety This electromechanical equipment is designed to produce high pressure gas.

More information

reduces flow setting time and setting errors!

reduces flow setting time and setting errors! Speed Controller with Indicator Numerical indication of handle rotation for flow rate reduces flow setting time and setting errors! New RoHS Indicator window Size Size or larger Indicator window Number

More information

Static dissipative Resin (Surface Resistivity : 10 4 ~10 7 Ω).

Static dissipative Resin (Surface Resistivity : 10 4 ~10 7 Ω). http://www.pisco.co.jp TUBE MAKE-TO-ORDER PRODUCTS for Anti-Static Environment Anti-Static 650 ESD Static dissipative Resin (Surface Resistivity : 10 4 ~10 7 Ω). Classification of conductivity region UE

More information

Thin pressure gauge. G401-W Series. Symbol Descriptions. A Connection A A. B Pressure display [MPa] P04 0 to 0.4MPa P10 0 to 1.

Thin pressure gauge. G401-W Series. Symbol Descriptions. A Connection A A. B Pressure display [MPa] P04 0 to 0.4MPa P10 0 to 1. Thin pressure gauge G401-W Series Thin, compact design ideal for incorporating devices. Suitable for filter regulator, regulator, and pressure switch (P4000-W). onnection: O ring seal, set screw G401-W

More information

Series VBA1110 to 4200

Series VBA1110 to 4200 Booster Regulator Series 0 to 4200 Specifications increase ratio Max. supply pressure Set pressure range Ambient and fluid temperature Lubrication Installation adjustable mechanism 0-02 400-04 Handle operated

More information

OPERATING AND MAINTENANCE MANUAL

OPERATING AND MAINTENANCE MANUAL Series 4300 Engineered Performance TABLE OF CONTENTS 0 INTRODUCTION 1 1 Scope 1 2 Description 1 3 Specifications 1 0 INSTALLATION 1 1 Mounting 1 2 Piping 1 1 Connecting Process Pressure 2 2 Vent Connections

More information

Dual Solenoid Gas Valve Installation

Dual Solenoid Gas Valve Installation Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing or servicing FLYNN Gas Products. Carefully follow all instructions in this bulletin and all instructions

More information

Filter regulator. Accessory. Description. Symbol. B With bracket With round. Port size. (Without limit indicator) Body size.

Filter regulator. Accessory. Description. Symbol. B With bracket With round. Port size. (Without limit indicator) Body size. eries ow to Order opper, fluorine and silicon-free + Low particle generation il ote 1) ote 2) part no. lean series hread type Rc racket assembly ote ) ote 9) 1.0a 0.2a / -20 49-01 49-2-01 ilter regulator

More information