SPECIFICATIONS APCEPH1

Size: px
Start display at page:

Download "SPECIFICATIONS APCEPH1"

Transcription

1 APCEPH1 ph CONTROLLER SPECIFICATIONS APCEPH1 Input voltage 120 Volts AC Maximum amperage VAC ph Accuracy +/- 0.2 ph ph Control range Adjustable ph Weight < 1 lbs Dimensions 3" x 6" x 3.5"

2 Basic Description The APCEPH1 has been designed to accurately and reliably measure and control the ph of any aqueous (water-based) solution, including hydroponic nutrient mixtures as well as fish aquariums. It does this by measuring the ph level of the water to be controlled and then it will automatically add ph adjustment (EITHER acid or alkali) to change the liquid s ph to the user s desired level. Note: Most water solutions will slowly change ph over time in a single direction (either raising OR lowering of the ph). The user can select their desired ph setting from 4.5 to 8.5 ph. Many other adjustable settings allow the APCEPH1 to be customized by the user for their specific needs. For best results, read and follow these instructions. Principal of operation The APCEPH1 consists of several components. Understanding how these components work together is critical to getting the most from the APCEPH1. 1. Sensors: Two sensors are provided with the system, a temperature sensor and a ph sensor. The sensors are connected to an in-line sensor interface cable. The sensors are then inserted into the sampling assembly. 2. APCEPH1SK - Sampling assembly (optional / sold separately): For best results, the sensors should have a constant flow of water to ensure they are accurately measuring the ph and temperature. The sampling assembly holds the two sensors and provides water flow across the sensors to accurately measure the water temperature and ph level. 1. SENSORS Sensor interface connects to controller 2. sampling ASSEMBLY* SAM-1 Sampling assembly *Sold separately Water inlet ph sensor probe Temperature sensor probe ph and temperature sensors inserted into sampling assembly Water outlet 2

3 3. Circulating pump: A circulating pump will constantly supply water to the sensor sampling assembly. The pump includes an inlet filter to ensure the sensors do not become fouled. The circulating pump will also provide good aeration of the water while operating. 4. Dosing pump: A chemically resistant low-voltage peristaltic pump is used to accurately transfer the ph adjustment liquid (acid or alkali) into the water. The pump comes with a lowvolt power supply. 5. Controller: The APCEPH1 controller is the brain of the system. The sensors and peristaltic pump connect to the controller. 3. submersible circulating pump* *Sold separately 4. peristaltic DOSIng pump ph adjustment liquid inlet ph adjustment liquid outlet 5. CONTROLLER LCD display 4 simple to operate push buttons Dosing pump connection 3

4 How it works Although the APCEPH1 may seem complicated, the basic operation of the unit is actually quite simple. The example below describes the operation of the APCEPH1 being used to lower the ph of a water tank / reservoir or aquarium. Let s assume that the user has selected ph down control with the following settings: ph = 6.0 dosing time = 10 seconds mixing time = 2 minutes ph deadband = 0.2 ph Up or Down = Down The ph sensor probe constantly measures the ph of the water to be controlled. In this example, when the ph levels rises beyond 6.0 ph, the unit will activate the dosing pump for 10 seconds. After the dosing pump stops, the mixing timer will start to count down for 2 minutes. The mixing timer is important to allow sufficient time for the ph adjustment acid to completely mix into the water. During the mixing time, the unit is waiting for the water to react to the addition of the ph adjustment liquid. By adding only a small amount of ph adjustment each dosing cycle, the ph level can be lowered slowly to the desired level. If too much ph adjustment is added to the water or if the mixing timer is set too low, the ph level could over-shoot the desired ph level. Once the mixing timer counts down to zero, the unit will again measure the ph level and determine if another dose is required (this is where the deadband setting works). In this example, the ph deadband is set at 0.2 ph. So if the ph sensor detects that the level has dropped from 6.0 to 5.8 or below, no other doses are required and the controller will not activate another dosing cycle. If the unit measures the ph to still be above 5.8 ph, additional ph dosing cycle(s) will continue to occur until the ph level goes down below the ph setting MINUS the deadband setting. (The deadband setting works just the opposite when raising the ph level ph setting PLUS the deadband). By adding ph adjustment slowly in small amounts, the ph level will gradually go down to the desired level without overshooting the ph setpoint. Ideally, the user should start with a low setting for the dose time and a high setting for the mixing time to allow plenty of time for the ph adjustment to stabilize. If the user has a large quantity of water to be controlled, the dosing and mixing timer settings may need to be increased. Smaller quantities of water can use lower dosing and mixing times. ph stock adjustment liquid reservoir *Provided by user Peristaltic pump APCEPH1 D1- PHC Chemical tubing ph sensor Sensor interface cable Temp sensor The sample pump will constantly operate to provide a sample of the current nutrient. The sample pump will also mix and aerate the nutrient. SAM-1 Hydroponic nutrient reservoir *Provided by user Sample pump (operates 24 hours) 4

5 Installation Sensor assembly 1. If you are using the APCEPH1SK sampling assembly, refer to the instructions to install the sensors. 2. If you are not using the APCEPH1SK sampling assembly, connect the probe cables and then secure the probes in the water to be measured. Using the sampling assembly Not using the sampling assembly Circulating pump 1. A circulating pump provides a constant flow of water to the sensors. The circulating pump should be connected to a constant power source. Note: For aquarium use, a filter pump head can be used to provide constant water flow to the sensor assembly. 2. Connect a piece of tubing from your circulating pump to one of the inlets on the sensor assembly (water can flow in either direction through the sampling assembly). The sensor assembly has been designed to mount on the side of the water tank / reservoir or a wall. The return side of the sensor assembly must be positioned so that the water will go back into the water tank / reservoir. A second piece of tubing can be used. Note: The inlet filter on the submersible pump should be cleaned frequently to ensure the sensor probes do not become dirty. Dosing pump 1. The dosing pump outlet tubing must be positioned to allow the ph adjustment liquid to enter the water tank/reservoir. The pump is self-priming and will transfer the ph adjustment liquid from the ph adjustment bottle into the water tank/ reservoir. Select a suitable location to secure the dosing pump. Note: Ensure you are using the correct ph adjustment (acid or alkali) based on your needs. 2. Once the dosing pump is secured, and the small tubing is securely connected to the pump s inlet and outlet, cut the tubing to the correct length. The inlet side of the tubing must reach into the bottom of the ph adjustment bottle, the outlet side is placed into the water tank / reservoir. 3. The peristaltic dosing pump inlet must be connected to the user s ph liquid adjustment bottle. The simplest way to do this is to drill or punch a small hole in the screw cap of your ph adjustment bottle. Then insert the small diameter chemically resistant tubing though the cap to the bottom of the ph adjustment bottle. 4. To prime the pump, plug the pump s power supply cable into a source of power and to the dosing pump. The pump will operate and slowly the ph adjustment liquid will be drawn up to the pump and out of the outlet tubing. Disconnect the dosing pump. 5

6 installation, cont. Controller 1. Connect the sensor interface cable to the controller. 2. Connect the ph sensor probe cable to the sensor interface cable. 3. Plug the controller into a source of power away from water. Note: Do not connect the dosing pump yet. Changing settings - menus The settings are listed below. When the user touches the MENU button, the LCD will show the user the menu items. If the user does not touch any button for 15 seconds, the LCD will revert back to the standard display. SETTING DESCRIPTION FACTORY SETTING SETTING RANGE PH setpoint Dosing time seconds Mixing time minutes ph deadband Select ph UP or DOWN User must select whether they are going to be increasing or decreasing ph. Down Up or Down Maximum # of doses Low ph limit High ph limit Minimum ph recorded Maximum ph recorded Dose count Calibrate 7.0 Calibrate 4.0 F or C display User can set maximum number of dosing cycles before an error will be activated. User can select the lowest allowable ph level. If the unit measures the ph level to be under this setting, the unit will shut down and trigger an error. User can select the highest allowable ph level. If the unit measures the ph level to be over this setting, the unit will shut down and trigger an error. Records lowest measured ph. Press Enter to reset the recorded Min value. Records lowest measured ph. Press Enter to reset the recorded Max value. Counts the number of dosing cycles. See Calibrating the ph Sensor for details. See Calibrating the ph Sensor for details. User can select either C or F for temperature display * ph ph Current value Current value n/a n/a 0 n/a 7.0 Fixed at Fixed at 4.0 F C or F *Note: If the ph level does not get to the ph set-point before the maximum dose count is reached, an error will be activated. 6

7 The 4 push buttons on the unit are UP / DOWN / Menu / Enter. When the user presses the Menu button, the first menu item will be displayed. Using the UP or DOWN buttons will scroll through the other menu items that can be customized by the user. When the user wants to change a setting, press the Enter button and the current setting will be blinking on and off to indicate the setting can be changed. Use the UP or DOWN buttons to change the setting. Press the Enter button a second time to accept the new setting and store it in memory. LCD display operation When the unit first powers up, there is a 1 minute warm-up period for the sensors to stabilize. During the first one minute of operation, the LCD will display the current measured readings. T E M P F P H 6. 0 W A R M U P P H T E M P After one minute (during normal operation), LCD display will display the following screen: T E M P F P H 6. 0 P H O O P R O B E S O K During ph DOWN dosing, the screen will change to display the following (the time setting will be shown on the right side of the LCD display and the timer will count down the remaining time): T E M P F P H 6. 0 P H D O W N T I M E 3 0 During ph UP dosing, the screen will change to display the following (the time setting will be shown on the right side of the LCD display and the timer will count down the remaining time): T E M P F P H 6. 0 P H U P T I M E 3 0 During mixing, the screen will change to display the following (the time setting will be shown on the right side of the LCD display and the timer will count down the remaining time): T E M P F P H 6. 0 M I X I N G T I M E

8 Manual Dose Test The user can manually test the dosing system by pressing Enter TWO TIMES. After pressing Enter the first time, the display will read: Press Enter to test dosing. Pressing Enter will force the dosing pump to activate. The dosing timer and the mixing timer will cycle one time. When the test is complete, the unit resumes normal operation. Error resetting If an error needs to be reset, holding the Enter button for 3 seconds will reset any fault. Error codes and trouble-shooting There are several error conditions that the unit will monitor. If an error is detected, the unit will alert the user to a problem. If there is an error detected, the backlit LCD display will be flashing on and off and the output to the dosing pump will be disabled. ph Sensor reading frozen for more than 48 hours If the sensor reading does not change by at least 0.01 ph in a 60-hour period, there could be something wrong with the sensor, or the sensor input. The user should check the calibration and function of the ph sensor. T E M P F P H 6. 0 P H S E N S O R L O C K Temp Sensor reading frozen for more than 48 hours If the sensor reading does not vary by at least.5 degree F in a 48 hour period, there could be something wrong with the temp sensor, or the sensor input. E R R O R P H 6. T T E M P S E N S O R L O C K If ph reading is below the Minimum setting If the unit reads a ph level below the minimum ph setting selected by the user, there could be something wrong with the sensor, the unit itself, the strength of the ph adjustment or even an empty reservoir. The user should check the calibration and function of the ph sensor. T E M P F E R R O R P H L O W L I M I T 8

9 If ph reading is above the Maximum setting If the unit reads a ph level above the maximum ph setting selected by the user, there could be something wrong with the sensor, the unit itself, the strength of the ph adjustment or even an empty reservoir. The user should check the calibration and function of the ph sensor. T E M P F E R R O R P H H I G H L I M I T Opposite reaction to dosing DOWN If ph dosing down, but the measured ph goes up, verify the correct ph adjustment liquid is being used. The user can also check the calibration and function of the ph sensor. T E M P F E R R O R P H D O S E U P? Opposite reaction to dosing UP If ph dosing up, but the measured ph goes down, verify the correct ph adjustment liquid is being used. The user can also check the calibration and function of the ph sensor. T E M P F E R R O R P H D O S E D O W N? Exceeded max doses After several dosing cycles, the unit should detect the ph level is now at the user s ph setting. If it takes too many doses to get the ph level to the desired setting, there is likely a problem. It could be a problem with the ph sensor or possibly the dosing pump is not operating correctly. This error may be caused by the ph adjustment bottle being empty. The dosing time or the maximum number of doses setting may need to be increased. T E M P F E R R O R M A X D O S E L I M I T Sensor or connection problems If there is a problem with the sensor interface, sensor connection or the sensors themselves, one of 2 errors will be displayed. If the sensor interface is disconnected after the unit has been operating for some time, the LCD will read: E R R O R E R R O R S E N S O R C O M F A I L 9

10 If the ph sensor is disconnected, or the ph sensor is faulty, the LCD will read: E R R O R E R R O R P H S E N S O R F A I L Current overload If the unit detects excessive current (greater than 4.5 amps) the current overload error will be displayed. Action: The output will be disabled until the unit is disconnected from the electric supply to reset the error. When the error occurs the unit will read: E R R O R E R R O R O V E R L O A D Factory settings reset The unit comes pre-programmed with standard settings that can be modified easily by the user. FACTORY DESCRIPTION SETTING ph setpoint 6.0 ph Dosing time 10 seconds Mixing time 4 minutes ph deadband 0.2 ph Select ph UP or DOWN Down Maximum # of Doses 40 Low ph limit 4.5 ph High ph limit 7.5 ph Minimum ph recorded Current value Maximum ph recorded Current value Dose count 0 Temp Mode (C or F) F Calibrate ph Calibrate ph Note: The factory settings can be recalled and the unit returned to factory settings at any time by pressing and holding the Menu and UP buttons for 3 seconds, then press Enter. Calibrating the ph sensor The APCEPH1 uses a high quality ph sensor, but all ph sensors can go out of calibration due to debris accumulating on the sensor surface or other factors. The APCEPH1 has a simple process to recalibrate the ph sensor. The temperature sensor NEVER requires calibration. Note: It is critical to FIRST calibrate the ph sensor to 7.0 ph. After Cal 7.0 is complete, you can calibrate to 4.0 ph. 1. Shut off water circulating pump. Remove the ph sensor from the ph sampling assembly. 2. Rinse the tip of the ph sensor with clean water to remove any accumulated dirt or debris. 3. Shake or wipe excess water from the sensor. 4. Place both the temp and ph sensor tip into a satchel or cup of fresh 7.0 calibration solution. Agitate the solution to ensure the sensor reads the calibration solution correctly. 5. To start the 7.0 calibration, press and hold the ENTER and UP push buttons for 3 seconds. 10

11 6. When the Calibrate 7.0 screen is displayed, press the Enter button to start the calibration process. After calibration, the unit will display the message 7.0 Calibration Complete. 7. If the user wants to calibrate to 4.0, repeat the process above using the 4.0 calibration solution and start the Calibrate 4.0 function using the ENTER and DOWN pushbuttons for 3 seconds. 8. When the Calibrate 4.0 screen is displayed, press the Enter button to start the calibration process. After calibration, the unit will display the message 4.0 Calibration Complete. Note: If the unit displays a Calibration error, check to make sure the calibration solution you are using is correct. Re-start the calibration process from the beginning with 7.0 ph. TROUBLESHOOTING The LCD lighted display is blinking on and off. All errors detected by the unit will cause the unit to go into safe-mode and disable the ph function. Refer to the Error codes and Troubleshooting section of the instructions. Note: All errors are reset by pressing and holding the Enter button for 3 seconds. When the error has been reset, the display will stop flashing and the unit will return to normal operation. The ph seems to be unstable and needs constant adjustment. All water solutions will experience ph changes, but if excessive aeration or certain biologically active nutrients are used, the ph changes could be more dramatic. Using the APCEPH1SK sampling assembly and the submersible mixing pump that comes with the APCEPH1SK will provide adequate mixing of the water without over-aeration. 11

12 WARRANTY INSTRUCTION AND MANUAL LIABILITY Limited Warranty Hydrofarm, Inc. doing business as Hydrofarm, Inc. (collectively HYDROFARM) warrants that for a period of three years from the date of purchase, this product will be free from defects in material and workmanship. HYDROFARM, at its option, will repair or replace this product or any component of the product found to be defective during the warranty period. Replacement will be made with a new or remanufactured product or component. If the product is no longer available, replacement may be made with a similar product of equal or greater value. This is your exclusive warranty. DO NOT attempt to repair or adjust any electrical or mechanical malfunctions on this product. Doing so will void this warranty and may cause serious injury/death/damage. This warranty is valid for the original retail purchaser from the date of the initial retail purchase and it not transferable. Keep the original sales receipt. Proof of purchase is required to obtain warranty performance. HYDROFARM dealers, distributors, service centers and retail outlets selling HYDROFARM products do not have any right to alter, modify or in any way change the terms and conditions of this warranty. This warranty does not cover normal wear of parts or damage resulting from the following: negligent use or misuse of the product, use on improper voltage or current, use contrary to the operating instructions, use contrary to any and all applicable local, state, provincial or federal laws, disassembly, repair or alteration by anyone other than HYDROFARM or an HYDROFARM authorized service center. Future, the warranty does not cover: Acts of God, such as fire, flood, hurricanes, tornadoes, nor Acts of War or Acts of Terrorism. What are the limits on HYDROFARM s liability? HYDROFARM shall not be liable for any incidental or consequential damages cause by the breach of any express, implied or statutory warranty or condition. Except to the extent prohibited by applicable law, any implied warranty or condition of merchantability or fitness for a particular purpose is limited in duration to the duration of the above warranty. HYDROFARM disclaims all other warranties, conditions or representations, express, implied, statutory or otherwise. HYDROFARM shall not be liable for any damages of any kind resulting from the purchase, use or misuse of, or inability to use the product including incidental, special, consequential or similar damages or losses of profits, or for any breach of contract, fundamental or otherwise, or for any claim brought against the purchaser by any other party. Some provinces, states or jurisdictions do not allow exclusion or limitations on how long an implied warranty lasts, so the above limitations or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights that vary from province to province, state to state or jurisdiction on jurisdiction. This warranty is offered by HYDROFARM,INC., If you have any other problem or claim in connection with this product, please write our Consumer Service Headquarters, HYDROFARM,INC. Copyright 2013 Hydrofarm, Inc. All rights reserved. Distributed by Hydrofarm, Inc. Made in China * *6 months for ph probe 12

OWNERS MANUAL. Model Shown with optional Primary Mooring Cleats. Portable Mooring System SAFETY OPERATION MAINTENANCE PARTS

OWNERS MANUAL. Model Shown with optional Primary Mooring Cleats. Portable Mooring System SAFETY OPERATION MAINTENANCE PARTS OWNERS MANUAL Model 2400 Shown with optional Primary Mooring Cleats. Portable Mooring System SAFETY OPERATION MAINTENANCE PARTS CAUTION: Before using your new Pier Tender, read rules for Safety, Operation,

More information

RAM 4021 Operation Manual

RAM 4021 Operation Manual RAM 4021 Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021 For your safety...3 Description...3 Set-up mode...4 Annunciator lights/alarms...4 Operation...5 Calibration...6

More information

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports URC Voltage Sensor SEN-VOLT 2013 Universal Remote Control, Inc. The information in this Owner s Manual is copyright protected.

More information

Simple, Robust, Reliable Measures ph Doses either acid (lower) or alkali (raise) Displays ph, Total Dose Count (DCT) and Dose Count per hour (DC/h)

Simple, Robust, Reliable Measures ph Doses either acid (lower) or alkali (raise) Displays ph, Total Dose Count (DCT) and Dose Count per hour (DC/h) Simple, Robust, Reliable Measures ph Doses either acid (lower) or alkali (raise) Displays ph, Total Dose Count (DCT) and Dose Count per hour (DC/h) Integrated peristaltic dosing pump When using automatic

More information

G7S Hand Pump Owner s Manual

G7S Hand Pump Owner s Manual G7S Hand Pump Owner s Manual Copyright Air Venturi 2018 Version 4-18 Specifications 24.80 inches long closed 43.31 inches long extended 4500 psi/310 bar max pressure Features Integral manometer (pressure

More information

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model User's Manual Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved

More information

NIV EAU MATIC ST User Manual Made in Canada

NIV EAU MATIC ST User Manual Made in Canada NIV EAU MATIC ST User Manual Made in Canada www.niveaumatic.com info@niveaumatic.com -2- Table of contents Introduction Section 1 Page 4 Installation Section 2 Pages 5 to 10 2.1 Control box 2.2 Sensor

More information

Owner s Manual Humiport 10/20

Owner s Manual Humiport 10/20 4201 Lien Rd Madison, WI 53704 Owner s Manual Humiport 10/20 Installation, Operation & Service Instructions Read and Save These Instructions The Phoenix Humiport line of ThermoHygrometers offers the restoration

More information

HAS2400 Hepa Air Scrubber

HAS2400 Hepa Air Scrubber HAS2400 Hepa Air Scrubber Diamonds Products 15 SW 40th Ave Great Bend, KS 67530 USA Toll Free: (866) 539-1694 Local: (620) 792-4542 Purchase Date: Serial Number: Purchased From: The DIAMOND HAS2400 HEPA

More information

UsER manual for Watersens ph -REDOX

UsER manual for Watersens ph -REDOX UsER manual for Watersens -REDOX Cl 8 1 2 6 3 3 7 7 4 4 4 4 Parts List 1 Redox Probe 1 x 2 PH Probe 1 x 5 Tube Weight 2 x 6 Connection Valve 1 x chlorine 3 Chlorine and Pumps 2 x 7 Dosing Valve 2 x 5 5

More information

RAM 4021-DPX Operation Manual

RAM 4021-DPX Operation Manual RAM 4021-DPX Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS ABL 4021-DPX / RAM 4021-DPX For Your Safety... 3 Description... 3 Setup Mode... 4 Lights/Alarms... 4 Operation...

More information

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc. Advanced Calibration Designs, Inc. Calibration Gas Instrument INSTRUCTION MANUAL Release I www.goacd.com Instruction Manual Gas Generator Release I TABLE OF CONTENTS I. General Description Page 2 II. Start-Up

More information

RAM Operation Manual

RAM Operation Manual RAM 4021-1 Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021-1 For Your Safety... 2 Description... 2 Setup Mode... 3 Lights/Alarms... 3 Operation... 4 Calibration...

More information

MODEL 100 NITROGEN INFLATION CART

MODEL 100 NITROGEN INFLATION CART MODEL 100 NITROGEN INFLATION CART Installation & Operation Information Branick Industries, Inc. 4245 Main Avenue P.O. Box 1937 Fargo, North Dakota 58103 REV120106 P/N: 81-0113 TABLE OF CONTENTS SAFETY

More information

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions RAM 4021 Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021 For Your Safety... 2 Description.... 2 Setup Mode.... 2 Lights/Alarms.... 3 Operation.... 4 Calibration....

More information

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions RAM 4021 Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021 For Your Safety... 2 Description.... 2 Setup Mode.... 2 Lights/Alarms.... 3 Operation.... 4 Calibration....

More information

PC1131 Electric Air Compressor

PC1131 Electric Air Compressor Senco Products Inc. 8485 Broadwell Road Cincinnati, Ohio 45244 PC1131 Electric Air Compressor Operating Instructions C US 2006, 2007 by Senco Products, Inc. Warnings for the safe use of this tool are included

More information

User Instruction Manual

User Instruction Manual User Instruction Manual 4500 psi Air Compressor Ver 2, 1.18 Contents Parts Included...3 Assembly Instructions...3-5 Operation Instructions...6-7 Oil Change Intervals...8 Air Filter Replacement...9 Setting

More information

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE INSTALLATION, OPERATION & MAINTENANCE MANUAL INTERFACE DEVICES, INC. 230 Depot Road, Milford, CT 06460 Ph: (203) 878-4648, Fx: (203) 882-0885, E-mail: info@interfacedevices.com

More information

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions RAM 4021-PR Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021-PR For Your Safety... 2 Description.... 2 Setup Mode.... 2 Lights/Alarms.... 3 Operation.... 4

More information

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company Installation and Operating Instructions DANGER: DO NOT MIX CHEMICALS! The Acid-Rite ph Adjustment System is designed for use with Axiall

More information

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP LIMITED WARRANTY Getz Equipment Innovators warrants its products, and component parts of any product manufactured by

More information

DISASSEMBLING & REASSEMBLING CARTRIDGE INSTALLING SEATPOST ON BIKE

DISASSEMBLING & REASSEMBLING CARTRIDGE INSTALLING SEATPOST ON BIKE INTRODUCTION BILL OF MATERIALS SPECIFICATIONS & TOOLS PROCEDURES DISASSEMBLING & REASSEMBLING CARTRIDGE INSTALLING SEATPOST ON BIKE OPERATION OF SEATPOST GIANT LIMITED WARRANTY 1 INTRODUCTION Congratulations

More information

Accu-Tab Systems 1000 Series by Axiall Corporation

Accu-Tab Systems 1000 Series by Axiall Corporation Accu-Tab Systems 1000 Series by Axiall Corporation Installation and Operating Instructions Model 1050 DANGER: DO NOT MIX CHEMICALS! The Accu-Tab chlorinator is designed for use with Axiall approved tablets

More information

Portable Gas Monitor GX User Maintenance Manual (H4-0050)

Portable Gas Monitor GX User Maintenance Manual (H4-0050) H4E-0050 Portable Gas Monitor GX-8000 User Maintenance Manual (H4-0050) Need of Maintenance and Servicing This gas monitor must be maintained in a normal state at all times to prevent accidents due to

More information

GE Measurement & Control

GE Measurement & Control GE Measurement & Control Psyclone Protimeter Thermo-Hygrometer Operating Manual INS7800, Rev. C August 2013 Psyclone is a Protimeter product. Protimeter has joined other GE high-technology sensing businesses

More information

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock or Electrocution: MODEL NUMBER: 20008 200 PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank IMPORTANT: It is

More information

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE MODEL NUMBER: M20005 AIR SOURCE KIT 30% Duty Compressor on 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE USER MANUAL IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock

More information

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES EXTREME SERIES PART NO. 45043 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product. SAVE THIS

More information

Installation Instructions Air Compressor Part # 2780, 2781

Installation Instructions Air Compressor Part # 2780, 2781 Note: It is essential that the operator of this product read and understand the contents of this manual before installing and using this product. Parts Included Qty Parts Included Qty Compressor 1 Coil

More information

Windy City II. User instruction manual WARNING: Fill pressure: 200 bar (approximately 2,900 psi)

Windy City II. User instruction manual WARNING: Fill pressure: 200 bar (approximately 2,900 psi) Windy City II User instruction manual Rules of safe shooting... 2 Filling the rifle... 3-4 Loading the magazine... 5-6 Inserting the magazine... 7 Adjusting the trigger... 7-8 Safety... 9 Warranty... 10

More information

Cocoa Patio Pond with Lit Spillway

Cocoa Patio Pond with Lit Spillway Cocoa Patio Pond with Lit Spillway REMINDER CALL 1-888-755-5641 BEFORE RETURNING TO STORE. PACKAGE CONTENTS ITEM # GQSPPB/GQSPPW Questions, problems, missing parts? Before returning to your retailer, call

More information

SMART Oxygen Analyzer. User Manual

SMART Oxygen Analyzer. User Manual SMART Oxygen Analyzer User Manual TABLE OF CONTENTS 1 WELCOME... 3 2 NITROXBUDDY2 OVERVIEW... 3 3 WARNINGS... 3 4 BEFORE FIRST USE... 3 5 QUICK GUIDE... 3 6 SETTINGS... 4 6.1 BUTTON... 4 6.2 DISPLAY...

More information

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR S S F U SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR MACHINERY DIVISION OWNER S MANUAL UNIT INSTRUCTIONS Please follow all SSFU Safety Instructions. Contact your Duro Dyne Tech Service if you have

More information

INTRODUCTION BILL OF MATERIALS SPECIFICATIONS & TOOLS PROCEDURES OPERATION OF SEATPOST GIANT LIMITED WARRANTY

INTRODUCTION BILL OF MATERIALS SPECIFICATIONS & TOOLS PROCEDURES OPERATION OF SEATPOST GIANT LIMITED WARRANTY INTRODUCTION BILL OF MATERIALS SPECIFICATIONS & TOOLS PROCEDURES OPERATION OF SEATPOST GIANT LIMITED WARRANTY 1 INTRODUCTION Congratulations on the purchase of your new GIANT CONTACT SWITCH seatpost. This

More information

100C Air Compressor Kit

100C Air Compressor Kit 10010 100C Air Compressor (standard mounting bracket, CE Spec) 10014 100C Air Compressor (no leader hose or check valve, CE Spec) 10016 100C Air Compressor (with Omega Bracket, CE Spec) IMPORTANT: It is

More information

444C DUAL PERFORMANCE VALUE PACK

444C DUAL PERFORMANCE VALUE PACK (Chrome) PART NO. 44432 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product. SAVE THIS MANUAL

More information

Accu-Tab Systems 2000 P Series by Axiall Corporation

Accu-Tab Systems 2000 P Series by Axiall Corporation Accu-Tab Systems 2000 P Series by Axiall Corporation Installation and Operating Instructions Models 2075 P 2150 P For NSF/ANSI-Standard 61 NSF STANDARD 61 applications use NSF/ANSI Standard 60 listed Axiall

More information

R E D I C O N T R O L S

R E D I C O N T R O L S R E D I C O N T R O L S Operation & Maintenance Manual Portable Service Purger for Low Pressure Chillers Model: PSP-LP-1B For Refrigerants R-11, R-113, R-114 & R-123 & Other Similar Refrigerants File Literature

More information

ROPV R40 E Series User Manual

ROPV R40 E Series User Manual HARBIN ROPV INDUSTRY DEVELOPMENT CENTER ROPV R40 E Series User Manual For Use with the Following ROPV Pressure Vessel Models: R40 300E R40 450E Headquarters Tel:(+86)451-82267301 Fax:(+86)451-82267303

More information

Psyclone TM. Protimeter Thermo-Hygrometer. GE Sensing. Operating Manual. INS7800, Rev. A (September 2007)

Psyclone TM. Protimeter Thermo-Hygrometer. GE Sensing. Operating Manual. INS7800, Rev. A (September 2007) GE Sensing Psyclone TM Protimeter Thermo-Hygrometer Operating Manual INS7800, Rev. A (September 2007) Psyclone is a Protimeter product. Protimeter has joined other GE high-technology sensing businesses

More information

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information Liquid Level EK-L CSM_EK-L_DS_E 3 Liquid Level That Is Unaffected by the Color of the or Liquid Mount to bypass pipes. Fit a wide range of pipe diameters: 8 to mm or to mm Built-in Amplifiers to save space.

More information

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO 400H HARDMOUNT AIR COMPRESSOR KIT PART NO. 40042 450H HARDMOUNT AIR COMPRESSOR KIT PART NO. 45042 400H 450H IMPORTANT: It is essential that you and any other operator of this product read and understand

More information

AUTOMATIC TIRE INFLATOR # MW-60, MW-60-4WAY & MW-64HP

AUTOMATIC TIRE INFLATOR # MW-60, MW-60-4WAY & MW-64HP USER MANUEL AUTOMATIC TIRE INFLATOR # MW-60, MW-60-4WAY & MW-64HP TIRE EQUIPMENT MANUFACTURER 1.866.409.RACK WWW.MARTINSINDUSTRIES.COM info@martinsindustries.com PARTS Verify that the following components

More information

200 PSI COMPRESSORS - MODEL NUMBERS

200 PSI COMPRESSORS - MODEL NUMBERS 200 PSI COMPRESSORS - MODEL NUMBERS 380C AIR COMPRESSOR KIT PART NO. 38033 480C AIR COMPRESSOR KIT PART NO. 48043 380C 480C IMPORTANT: It is essential that you and any other operator of this product read

More information

PURITY INSTALLATION INSTRUCTIONS MODEL P40

PURITY INSTALLATION INSTRUCTIONS MODEL P40 Sunshine Pool Products, LLC Manufacturer of Quality Pool & Spa Products 902 West 2010 South, Syracuse, Utah 84075 Voice: 801-825-4523 Website: www.sunshinepool.com Email: info@sunshinepool.com PURITY INSTALLATION

More information

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only) 42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) 42047 Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only) 45052 Constant Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock: - Do not disassemble. Do not attempt repairs or modifications. Refer to qualified service agencies for all service and repairs.

More information

ENVIRONMENTAL INSTRUMENTS, LLC

ENVIRONMENTAL INSTRUMENTS, LLC Model FL-3A Fluoroprobe ENVIRONMENTAL INSTRUMENTS, LLC 144 Industrial Park Drive Suite A-3 Waynesville, NC 28723 Phone: 828-452-7776 www.thefluoroprobe.com Changing the way the world measures oxygen O

More information

Nothing's as cool, as a freshwater pool. easychem 770 ORP and ph Controller for Pools and Spas with Timer Output for Pool Pump

Nothing's as cool, as a freshwater pool. easychem 770 ORP and ph Controller for Pools and Spas with Timer Output for Pool Pump Page 1 of 6 TPS Australia - Quality hand-made instruments since 1968. Nothing's as cool, as a freshwater pool easychem 770 ORP and ph Controller for Pools and Spas with Timer Output for Pool Pump Automatic

More information

Digital Vacuum Regulator

Digital Vacuum Regulator Temperature Control for Research and Industry Digital Vacuum Regulator User s Manual Model DVR-380 INDEX SECTION PAGE SAFETY NOTICES................................................. 3 1. QUICK OPERATING

More information

Please Do Not Return This Product To The Store!

Please Do Not Return This Product To The Store! MODEL NUMBER: GM000W - GAMEMAKER TORCH O W N E R ' S M A N U A L PLEASE READ AND FOLLOW THIS MANUAL IN ITS ENTIRETY BEFORE USE. DOING SO WILL PROVIDE HELPFUL HINTS THAT WILL AID IN GETTING MAXIMUM USE

More information

400C & 450C DUAL PERFORMANCE VALUE PACKS

400C & 450C DUAL PERFORMANCE VALUE PACKS (Chrome) PART NO. 40013 (Silver) PART NO. 45012 (Chrome) PART NO. 45013 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before

More information

4 and 8 Station PDS Control Installation & Operators Manual

4 and 8 Station PDS Control Installation & Operators Manual 4 and 8 Station PDS Control Installation & Operators Manual 1402-15 11/2000 June 2003 MW1402C Chore-Time Warranty 4 and 8 Station PDS Control Chore-Time Warranty Chore-Time Equipment ( Chore-Time ) warrants

More information

200 PSI FAST-FILL AIR SOURCE KIT

200 PSI FAST-FILL AIR SOURCE KIT 200 PSI FAST-FILL AIR SOURCE KIT 55% Duty Compressor on 2.0 Gallon Air Tank PART NO. 20007 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of

More information

200 PSI HIGH-FLOW AIR SOURCE KIT

200 PSI HIGH-FLOW AIR SOURCE KIT 200 PSI HIGH-FLOW AIR SOURCE KIT 50% Duty Compressor on 2.0 Gallon Air Tank PART NO. 20008 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of

More information

Foldable Magne c Exercise Bike

Foldable Magne c Exercise Bike ASSEMBLY INSTRUCTIONS Foldable Magne c Exercise Bike CAUTION! Please make sure the pedals are attached to the correct sides, L to left and R to right. Screw in the right pedal clockwise and the left counter-clockwise.

More information

The Univentor 1250 Anaesthesia Unit

The Univentor 1250 Anaesthesia Unit THE UNIVENTOR 1200/1250 ANAESTHESIA UNIT The Univentor 1250 Anaesthesia Unit TABLE OF CONTENTS EDITION 1 Section 1 - WARRANTY & SERVICE 1.1. WARRANTY 2 1.2. DAMAGED SHIPMENTS 2 1.3. SERVICE 2 Section 2

More information

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel: PERMA PURE INSTRUCTION MANUAL FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model 3300 Version 4.06 Perma Pure LLC Tel: 732-244-0010 P.O. Box 2105, 8 Executive Drive Tel: 800-337-3762 (toll free US)

More information

T EK-SUB 4800C 19 mm Submersible Level Transmitter

T EK-SUB 4800C 19 mm Submersible Level Transmitter Technology Solutions T EK-SUB 4800C 19 mm Submersible Level Transmitter Instruction Manual Document Number: IM-4800C www.tek-trol.com Table of Contents 1 Safety Instructions... 2 1.1 Intended Use... 2

More information

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO 420C AIR COMPRESSOR KIT PART NO. 42042 460C AIR COMPRESSOR KIT PART NO. 46043 420C 460C IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this

More information

StockWeigh 500 D3632 US-B

StockWeigh 500 D3632 US-B OPERATORS MANUAL DIGI-STAR 790 WEST ROCKWELL AVENUE FORT ATKINSON, WISCONSIN 53538 PHONE: (920) 563-1400 TECHNICAL SERVICE: 1-800-225-7695 (920) 563-9700 D3632 US- Rev. B August 4, 2004 StockWeigh 500

More information

8675/8677/8678 OWNER S MANUAL

8675/8677/8678 OWNER S MANUAL 8675/8677/8678 OWNER S MANUAL SERIAL NUMBER: DATE OF MANUFACTURE: 8675 MAXIMUM PATIENT WEIGHT: 250 LBS. 8677/8678 MAXIMUM PATIENT WEIGHT: 375 LBS. 1316 Eisenhower Blvd Johnstown, PA 15904 (814) 266 8726

More information

Saline C 6.0 Junction Box

Saline C 6.0 Junction Box ISHCSJBOX RevA Saline C 6.0 Junction Box Junction Box for Saline C 6.0 Commercial Salt Chlorine Generator Owner s Manual Contents Description...3 Installation...4 Operation...7 Maintenance...8 Parts Guide...9

More information

Accu-Tab PowerBase 3012AT by Axiall Corporation

Accu-Tab PowerBase 3012AT by Axiall Corporation Accu-Tab PowerBase 3012AT by Axiall Corporation Installation and Operating Instructions DANGER: DO NOT MIX CHEMICALS! The PowerBase 3012AT chlorinator system is designed for use with Axiall Corp. approved

More information

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES 450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES PART NO. 45053 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing

More information

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm) Pressure Sensor (Stainless Steel Diaphragm) CSM DS_E_3_1 Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications Incorporates double diaphragms consisting of SUS316L stainless

More information

Vessel Installation and Operating Manual

Vessel Installation and Operating Manual For In-ground and Aboveground Pools Vessel Installation and Operating Manual Important Safety Information Please read this manual prior to installation. Nature 2 Express is designed to sanitize in-ground

More information

Installation and Operating Manual

Installation and Operating Manual Safety Instructions Important Information Please read prior to installation ATTENTION! ELECTRICAL HAZARD FOR INGROUND POOLS AND ABOVEGROUND POOLS Installation and Operating Manual IMPORTANT Pool Owner,

More information

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO 97C COMPRESSOR KIT 12V PART NO. 00097 97C COMPRESSOR KIT 24V PART NO. 02497 98C COMPRESSOR KIT PART NO. 00098 97C 98C IMPORTANT: It is essential that you and any other operator of this product read and

More information

PERSONAL AIR BREATHING UNIT

PERSONAL AIR BREATHING UNIT PERSONAL AIR BREATHING UNIT Operation & Maintenance Manual MARTECH SERVICES C O M P A N Y 1-800-831-1525 Table of Contents INTRODUCTION: Page 2 COMPONENTS DRAWING: Page 3 START UP: Page 4 OPERATION: Page

More information

USER MANUAL. DM65 Manual Flush/Tilt Combo Mount

USER MANUAL. DM65 Manual Flush/Tilt Combo Mount USER MANUAL DM65 Manual Flush/Tilt Combo Mount 1 D1_1.11.11.indd 1 ! CAUTION When using this mounting system, basic precautions should be followed, including: Follow the entire installation/user s manual

More information

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet: OXY Integral INTERCON ENTERPRISES INC Tel: 800 665 6655 Fax: 604 946 5340 E-Mail: sales@intercononline.com Internet: www.intercononline.com Manual Integral 2006 1 INDEX 2-3 PREFACE 4 INTRODUCTION 5 Principle

More information

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr A DIVISION OF THE FREDERICKS COMPANY 2400 PHILMONT AVE. HUNTINGDONVALLEY, PA 19006 PARTS LIST 1 3 4 2 # QTY ITEM DESCRIPTION

More information

User s Guide. CO2 & O2 Controller for miniature incubators

User s Guide. CO2 & O2 Controller for miniature incubators CO2 O2 Control User s Guide CO2 & O2 Controller for miniature incubators Precise CO2 & O2 Control throughout the experiment Media ph control Compatible with any perfusion system Miniature incubators for

More information

120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank

120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank 120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank PART NO. 20003 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of

More information

User manual CF8-D/W-IN

User manual CF8-D/W-IN User manual CF8-D/W-IN General The sensor CF8-D/W-IN is used to measure the carbon dioxide concentration inside incubators. All functions can be modified from a PC with the communication cable. UMA 48

More information

CSA Sample Draw Aspirator Adapter Operator s Manual

CSA Sample Draw Aspirator Adapter Operator s Manual 30-0951-CSA Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0367 Revision: 0 Released: 4/30/15 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating

More information

SMART Carbon Monoxide Analyzer. User Manual

SMART Carbon Monoxide Analyzer. User Manual SMART Carbon Monoxide Analyzer User Manual TABLE OF CONTENTS 1 WELCOME... 3 2 MONOX OVERVIEW... 3 3 WARNINGS... 3 4 BEFORE FIRST USE... 3 5 QUICK GUIDE... 3 6 SETTINGS... 4 6.1 BUTTON... 4 6.2 DISPLAY...

More information

MODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR

MODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR MODEL NUMBER: 45043-450P-A AUTOMATIC PORTABLE COMPRESSOR IMPORTANT: It is essential that you and any other operator of the product read and understand the contents of this manual before installing and

More information

HUBEN K1 Pre-charged Pneumatic Air Rifle Owner s Manual

HUBEN K1 Pre-charged Pneumatic Air Rifle Owner s Manual HUBEN K1 Pre-charged Pneumatic Air Rifle Owner s Manual 5135 Naiman Parkway, Cleveland, OH 44139 l 216-220-1180 Record the serial number of your airgun... READ THIS MANUAL AND THE WARNINGS AND SAFETY PROCEDURES

More information

BUBBLER CONTROL SYSTEM

BUBBLER CONTROL SYSTEM BUBBLER CONTROL SYSTEM Description: The HDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air

More information

APCO ASU-SCAV & ASU-CAV SINGLE BODY COMBINATION AIR VALVES

APCO ASU-SCAV & ASU-CAV SINGLE BODY COMBINATION AIR VALVES APCO ASU-SCAV & ASU-CAV SINGLE BODY COMBINATION AIR VALVES Instruction D12039 December 2015 Instructions These instructions provide installation, operation and maintenance information for the. They are

More information

Digital Vacuum Regulator

Digital Vacuum Regulator Temperature Control for Research and Industry Digital Vacuum Regulator User s Manual Model 300 INDEX SECTION PAGE 1. QUICK OPERATING INSTRUCTIONS........................... 3 Safety Notices.................................................

More information

Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values. Operations Manual

Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values. Operations Manual Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values Operations Manual Please read, understand, and follow these instructions before operating this equipment.

More information

PM105 PRESSURE METER USER S MANUAL

PM105 PRESSURE METER USER S MANUAL PM105 PRESSURE METER USER S MANUAL Manual revision: 15 March, 2001 SCSMANP015 Copyrighted 2001 Thank you for purchasing a Tek Know pressure meter. The Tek Know products are manufactured by Scan-Sense AS

More information

Operating Instructions Part No

Operating Instructions Part No DIGITAL AUTOMATIC TYRE INFLATOR Operating Instructions Part No. 11.0578 Thank you for selecting this Jamec Pem Automatic Tyre Inflator. Please read this manual before carrying out any installation or service

More information

Tactical Sniper air rifle & carbine

Tactical Sniper air rifle & carbine Tactical Sniper air rifle & carbine User instruction manual Fill pressure: 200 bar (approximately 2,900 psi) Rev 4/17 Contents Rules of safe shooting... 3 Filling your rifle... 4-5 Loading the magazine...

More information

Digital Vacuum Regulator

Digital Vacuum Regulator Temperature Control for Research and Industry Digital Vacuum Regulator User s Manual Model DVR-280 INDEX SECTION PAGE 1. QUICK OPERATING INSTRUCTIONS............................. 3 KEM-NET DATA LOGGING

More information

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor INSTALLATION and INSTRUCTION MANUAL for QUALITY AIR BREATHING SYSTEMS Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor M A R T E C H S E R V I C E S C O M P A N Y P.O. Box 7079 OFFICE: (507)

More information

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO 250C-IG COMPRESSOR KIT 12V PART NO. 25050 250C-IG COMPRESSOR KIT 24V PART NO. 25058 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual

More information

CHEMICAL INDUCTION KIT (Pt.No Issue 6, October 2015)

CHEMICAL INDUCTION KIT (Pt.No Issue 6, October 2015) CHEMICAL INDUCTION KIT (Pt.No.2400-0740 Issue 6, October 2015) DESCRIPTION The C-Dax Chemical Induction Kit is an accessory kit for the GoldLine range of three point linkage sprayers. The system operates

More information

480C DUAL PERFORMANCE VALUE PACK

480C DUAL PERFORMANCE VALUE PACK (Pewter) PART NO. 48012 (Chrome) PART NO. 48032 (Stealth Black) PART NO. 48042 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual

More information

DB 61 Dolphin TMV3 Integrated Thermostatic Mixing Valve

DB 61 Dolphin TMV3 Integrated Thermostatic Mixing Valve INSTALLATION AND MAINTENANCE GUIDE DB 61 Dolphin TMV3 Integrated Thermostatic Mixing Valve Saving water, saving power, promoting hygiene Important: Read carefully before installing product DOLPHIN Revision

More information

Model AUTOMATIC UPPER ARM Blood Pressure Monitor

Model AUTOMATIC UPPER ARM Blood Pressure Monitor AUTOMATIC UPPER ARM Blood Pressure Monitor Model 1130 Real Fuzzy t e c h n o log y Features: Real Fuzzy Technology Automatic 60 sets of memory One-Touch Operation Easy-to-read Display Table of Contents:

More information

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO 250C-IG COMPRESSOR KIT 12V PART NO. 25050 250C-IG COMPRESSOR KIT 24V PART NO. 25058 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual

More information

BUBBLER CONTROL SYSTEM

BUBBLER CONTROL SYSTEM BUBBLER CONTROL SYSTEM Description: The LDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air

More information

User Manual. Heads-Up Display (HUD) DiveCAN. Mechanical Button Version

User Manual. Heads-Up Display (HUD) DiveCAN. Mechanical Button Version User Manual Heads-Up Display (HUD) Mechanical Button Version DiveCAN Table of Contents 1. Introduction...4 1.1 Features...4 2. Physical Description...5 3. Reading the PPO2...6 3.1 Modified Smither s Code...7

More information

SPS-5. Rate Computing Scale. Operation Manual

SPS-5. Rate Computing Scale. Operation Manual SPS-5 Rate Computing Scale Operation Manual Revision 1.0 October 17, 1996 1996 Transcell Technology, Inc. Contents subject to change without notice. Transcell Technology, Inc. 975 Deerfield Parkway Buffalo

More information

Operation Manual. Pro CO 2 Analyzer. Carbon Dioxide Analyzer. Rev

Operation Manual. Pro CO 2 Analyzer. Carbon Dioxide Analyzer. Rev Operation Manual Pro CO 2 Analyzer Carbon Dioxide Analyzer Rev. 10.17 Quick Reference Guide READ ENTIRE MANUAL BEFORE USE 1. To switch on, hold the On/Off button until the display powers up. 2. To turn

More information