2 FILTER TYPE PRESSURE SNUBBER Pressure oscillations and other sudden pressure changes can affect the delicate mechanisms of a pressure gauge or pressure transmitter. This can result in either complete failure of the instrument or false and inaccurate readings. Pressure snubbers are designed to reduce or prevent these oscillations and fluctuations from reaching and affecting pressure instruments. Pressure snubbers reduce pressure spikes only; a pressure snubber will not eliminate any prolonged overpressure. Spikes last for milliseconds only, over pressures lasting longer than that can damage the pressure sensor. The pressure snubbers below are the filter type using a porous filter media made of sintered metal. Because the filter element is a fine mesh type, it should be used on processes that do not contain particulate or sludge that would clog the element. In the event that the snubber does get clogged, our snubbers can be disassembled for cleaning if necessary. SPECIFICATIONS: Connection Sizes: 1/4" or 1/2"NPT Stainless Steel or Brass Water, Air, Oil or Gas No Moving Parts Nothing to break or wear out Pressure Rating: Brass: 3,000 PSI Stainless Steel: 10,000 PSI Snubber Body Retaining Screw Snubber Element Gauge Connection Brass or 316 SS Brass or 316 SS Brass or 316 SS ½ or ¼ NPT Female Process Connection ½ or ¼ NPT Male A (Inches) B (Inches) A (MM) B (MM) 1/4"NPT mm 35mm 1/2"NPT mm 44mm Other Instrument protection accessories: Piston Type Snubber Adjustable Snubber Needle Valve Pressure Limiting Valve Page 73
3 ADJUSTABLE PRESSURE SNUBBER SNUBBER Fully field adjustable In stock for immediate delivery Choice of Brass or Stainless Steel FEATURES AND BENEFITS Pressure Pulsation Dampener Adjustable Dampening Protects pressure gauges against pressure spikes, surges, and fluid hammers. Can isolate the gauge for service or replacement. Available in both Stainless Steel and Brass in 1/4", 3/8", and 1/2" NPT connection sizes. Fine thread adjustable valve allows user to fine tune harmful harmonic vibration from fluid systems Precision ball affords shock protection during pressure spikes or fluid hammer conditions. Most economical "life insurance" for instrumentation reliability. Simple, Clever, Economical Part No. MSB4 MSS4 MSB6 MSS6 MSB8 MSS8 Body Material Brass SS Brass SS Brass SS "A" Thd. Size "B" "C" "D" Hex 1/4-18NPT 1/4-18NPT 3/8-18NPT 3/8-18NPT 1/2-1/4-NPT 1/2-14--NPT.51 (13mm).51 (13mm).59 (16mm).59 (16 mm.79 (20mm).79 (20mm) 1.77 (45mm) 1.77 (45mm) 2.36 (60 mm) 2.36 (60 mm) 2.36 (60mm) 2.36 (60mm).67 (17mm).67 (17mm) 1.18 (30mm) 1.18 (30mm) 1.18 (30mm) 1.18 (30mm) Maximum Pressure 3,000 PSI 5,000 PSI 5,000 PSI 10,000 PSI 5,000 PSI 10,000 PSI Page 74
4 PISTON TYPE PRESSURE SNUBBER While each model is built to exacting specifications with tolerances to ten-thousandths of an inch, the unit-to-unit uniformity and easy piston changing makes installing a piston type Snubber into your system a smart choice. Center Body Snubbers MODEL NO. CONNECTIONS INLET MODEL 010 OUTLET BODY MATERIAL 010B Brass S 1/4 NPT 1/4 NPT 303 Stainless 5000 MAX PSI LN. HEX SS 316 Stainless 5000 Available in British Taper Pipe Threads. Add BSP to part number when ordering. MODEL 050 CONNECTIONS MODEL NO. BODY MTRL MAX PSI LN. HEX INLET OUTLET 050B 3/8 NPT 3/8 NPT Brass Available in British Taper Pipe Threads. Add BSP to part number when ordering. MODEL 060 MODEL NO. CONNECTIONS INLET OUTLET BODY MTRL MAX PSI LN. HEX 060B Brass S 1/2 NPT 1/2 NPT 303 Stainless SS 316 Stainless Available in British Taper Pipe Threads. Add BSP to part number when ordering. Page 75
5 PRESSURE LIMITING VALVE ADVANTAGES : PREVENT DAMAGE TO GAUGE / INSTRUMENTS DUE TO SUDDEN PRESSURE SURGE 316SS CONSTRUCTION COMPACT DESIGN AUTOMATIC POSITIVE ACTION IN LINE INSTALLATION REPEATABLE PEFORMANCE MAXIMUM WORKING PRESSURE 6,000 PSI Part Numbering System PLV = PRESSURE LIMITING VALVE 4 = ¼ NPT 2 = ½ NPT M = MALE NPT THREAD F = FEMALE NPT THREAD RANGE = SEE BELOW Example: PLV-2F-2F- 1 SET: 80PSI Available Configurations PLV ½ male ½ male 6,000 PSI PLV ½ male ½ female 6,000 PSI PLV ½ female ½ female 6,000 PSI PLV ¼ female ¼ female 6,000 PSI PLV ¼ male ¼ male 6,000 PSI PLV ¼ male ¼ female 6,000 PSI TECHNICAL FEATURES: Available Ranges RANGE Adjustment Span in PSI 1 50 to 120 PSI 2 80 to 180 PSI to 300 PSI to 600 PSI to 1000 PSI to 1800 PSI to 3000 PSI to 6000 PSI PIC Pressure Limiting Valves are also called over-load protectors or gauge savers. The PLV cuts off pressure rising above the desired pressure value (pre-set value) thus preventing failure of pressure gauge or instruments and also stops possible damages such as hazardous leakages and explosions etc. The Pressure Limiting Valve or gauge saver shuts off the system with quick and positive action of built in push-rod device. As and when, the pressure falls below the pre-set pressure value, the line and/or the pressure gauge will be automatically put into operation again. The PLV is of extreme importance and necessity for the protection of the pressure sensitive instruments against over pressures, sudden line induced pressure surges which are principal causes of the instrument and subsequent system failure. The PLV can be supplied to function at different cut-off pressure values on special request. The repeat accuracy of the unit depends on the rate of pressure rise. However, an accuracy of ± 10% of the set pressure may be expected. Page 77
6 Syphon (Pigtail) Pigtail Siphons are typically used to act as a cooling or warming leg for applications where the process temperature is higher or lower than the normal working temperature range as specified by NIST B40.1 in relation to instrumentation. Temperature extremes can cause inaccuracy or shorten the life span of instruments not specifically designed for severe duty applications. STRAIGHT ANGLE Part No. Description Pressure Temperature A03B ¼ NPT Brass Pigtail 250PSI 400 F A031 ¼ NPT Iron Pigtail, Schedule 40 Iron 500PSI 400 F CPS4 ¼ NPT Steel Pigtail, Schedule 80 Steel 1000PSI 850 F CPS2 ½ NPT Steel Pigtail 1000PSI 850 F CPSS4 ¼ NPT Stainless Steel Pigtail 2000PSI 1000 F CPSS2 ½ NPT Stainless Steel Pigtail 2000PSI 1000 F
7 COOLING TOWER Temperature Affects Pressure Gauges: Mechanical pressure gauges are typically designed and calibrated to be most accurate and durable in ambient conditions between 65 and 85 F, with process temperatures not exceeding 150 F. If required, gauges can be ordered - calibrated to be most accurate for specific temperature ranges (within certain limits) Outside of the normal working conditions temperature can affect the accuracy and lifespan of gauges. Precautions should be taken to ensure that pressure gauges are not continuously exposed to temperature extremes. Good gauge practices have always recommended pigtail siphons (a) for steam or other high temperature applications. Other optional preventative measures include capillary (b) to remote mount the gauge away from the process or cooling towers to dissipate heat from the process fluid before it enters the gauge. This can also be true for low temperature extremes such as cryogenic applications. Other methods for protecting instruments from temperature extremes: (a) Pigtail Siphon ( b) Capillary Page 76
8 TEST PORT PLUGS Piping System Test Plugs These test ports are designed for permanent installation into piping system for quick access during maintenance checks. With gauge adapters for pressure tests or pocket thermometer insertion without shutting down or draining the system. Available with Nordel or Neoprene Cores, Brass or Stainless Steel bodies in 1/8 NPT through 1/2 NPT Model Number Nominal Size (in) OAL (in) Material Pressure/ Temperature Lower Connection (in) Body Hex (in) Cap Hex (in) Core Material PLUG-1/8 1/8 NPT 1-1/4 Brass 200F/1000PSI 1/8 NPT 13/16 9/16 Neoprene PLUG-1/4 1/4 NPT 1-1/2 Brass 200F/1000PSI 1/4 NPT 1-1/16 1-1/2 Neoprene PLUG-3/8 3/8 NPT 1-1/2 Brass 200F/1000PSI 3/8 NPT 1-1/16 1-1/2 Neoprene PLUG-1/2 1/2 NPT 1-1/2 Brass 200F/1000PSI 1/2 NPT 1-1/16 1-1/2 Neoprene PLUG-1/4SS 1/4 NPT 1-1/2 SS F/1000PSI 1/4 NPT 1-1/16 1-1/2 Neoprene PLUG-1/2SS 1/2 NPT 1-1/2 SS F/1000PSI 1/2 NPT 1-1/16 1-1/2 Neoprene Pressure & Temperature Test Plugs Acessories PCR Plastic Cap Retainer - Available for all test plugs ADAPTER-PP-1/4 1/4" Gauge Adaptor 2-3/4" OAL x 1-3/4" x 0.063" probe ADAPTER-PP-1/2 1/2" Gauge Adaptor 2-3/4" OAL x 1-3/4" x 0.125" probe PG Probe guard for all gauge adapters Page 72
Model BR-PCS SPECIFICATIONS:
PRESSURE CONTROLLER WITH INDICATOR Model BR-PCS product overview: The Blue Ribbon Model BR-PCS is an intelligent pressure controller with an array of functions that include 4-20mA, 2-way PNP or NPN and
More informationBuying more than 11 gauges? Call Lesman for additional discounts.
Low Cost Liquid Filled Pressure Gauges Size: 1.5", 2", and 2.5" Accuracy: 2.5% of full scale Materials: Case and ring: 304 stainless steel; Window: Polycarbonate; Seals: Buna-N; Pointer: Black-finished
More informationPULSATION DAMPENER / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS
PULSATION / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS FUNCTIONS: 1. Pulsation Dampener smooths pump flow 2. Surge Suppressor absorbs shocks and vibrations 3. Water Hammer Arrestor eliminates
More informationSPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION
DIFFUSION-RESISTANT, DIAPHRAGM SEAL, EXCESS FLOW SHUT-OFF VALVES (FS SERIES) FS Series Excess Flow Shut-Off Valves are designed to automatically shut-off the delivery of gas in a line if the flow exceeds
More informationHigh Precision Gauge Pressure Indicators
Series 1500 8½" Dial High Precision Gauge Pressure Indicators Series 1500 Gauges have capsule-type pressure elements up to and including the 150-psig range. Ranges of 200 psig and above have Bourdon tubes.
More informationHydraulic comparison test pump Models CPP1000-X, CPP1600-X
Calibration Hydraulic comparison test pump Models CPP1000-X, CPP1600-X WIKA data sheet CT 91.12 for further approvals see page 2 Applications Calibration service companies and service industry Maintenance
More informationHydraulic hand test pump Models CPP700-H and CPP1000-H
Calibration technology Hydraulic hand test pump Models CPP700-H and CPP1000-H WIKA data sheet CT 91.07 for further approvals see page 2 Applications Simple test pressure generation on site, in the laboratory
More informationCOMPRESSED AIR SAVING PRODUCTS INDEX. Useful information AIR-SAVER G1 AIR-SAVER G2 LOCATOR. Condensate Management Specialist
INDEX Useful information AIR-SAVER G1 AIR-SAVER G2 LOCATOR COMPRESSED AIR SAVING PRODUCTS Condensate Management Specialist Information provided herewith is believed to be accurate and reliable. However,
More informationINSTALLATION AND OPERATING INSTRUCTIONS
INSTALLATION AND OPERATING INSTRUCTIONS For 3D Instruments Direct Drive Pressure Gauges 3D Instruments Inc., 15542 Chemical Lane, Huntington Beach, CA, 92649, U.S.A. Tel. (714) 894-5351, Fax. (714) 895-4309
More informationAIR CHUCKS, TIRE GAUGES AND INFLATOR GAUGES
Series AIR CHUCKS, TIRE GAUGES AND INFLATOR GAUGES Standard Air Chucks 374 Flow-Thru Air Chucks 375 Standard Pencil Tire Gauges 376 Dual Foot Tire Gauges 377 Dial Tire Gauges 378 Digital Tire Gauges 379
More informationSchroeder Check Test Point System
Perforated polyamide / kevlar hose, 2 mm ID, 5 mm OD, plastic dust cap. L in (mm) P (max) psi (bar) 6 (150) 10,000 (680) 12 (300) 10,000 (680) 24 (610) 10,000 (680) 36 (915) 10,000 (680) 48 (1220) 10,000
More informationPRESSURE & TEMPERATURE GAUGES PRESSURE TEMPERATURE. Catalogue H20200a
PRESSURE & TEMPERATURE GAUGES PRESSURE Catalogue TEMPERATURE Applications The label Trafag Industrial Components extends the Trafag brand name to instruments manufactured by qualified partner companies.
More information3.0 Pressure Transmitter Selection
3.0 Pressure Transmitter Selection Each Tronic Line pressure transmitter has different features to meet specific performance, environmental, and price requirements. It is not possible to describe every
More informationRelated Products: Auto Drain Valve. Model/Specifications. Model
Related Products: Auto Drain Valve /600 Drainage is automatically discharged in a reliable manner, without requiring human operators. Highly resistant to dust and corrosion, operates reliably, and a bowl
More informationPneumatic Hand Pumps with no Gauge Connection (scissor handle) AP0V (300 psi / 20 bar)
Pneumatic Hand Pumps with no Gauge Connection (scissor handle) AP0V (300 psi / 20 bar) The quickest and most economical way to perform pneumatic field pressure calibrations on pressure transmitters, switches
More informationPremium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.
Premium Series High Quality Forged Brass Body Rust-Resistant Nickel Plated Finish Long Life Corrosion Resistant Valve Seat Economical Price & Reliable Performance Tamper-Resistant locking Screw Reduces
More informationB74G - EXCELON Modular System General purpose filter/regulator
> Port size: /8... / (ISO G/PTF) > Excelon design allows in-line installation or modular installation with other Excelon products > Push to lock adjusting knob with optional tamper resistant accessory
More informationStandard Operating and Maintenance Instructions for Pumping System Model PS-90
Standard Operating and Maintenance Instructions for Pumping System Model PS-90 High Pressure Equipment Company 2955 West 17th Street, Suite 6 PO Box 8248 Erie, PA 16505 USA 814-838-2028 (phone) 814-838-6075
More informationMaximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications
Outstanding performance in extremely low pressure and low pressure ranges from 0.003 to. Realizing high performance, energy saving, and compact size. Realize precise pressure control in a pressure range
More informationGILMONT ACCUCAL FLOWMETERS
OPERATING MANUAL GILMONT ACCUCAL FLOWMETERS 28W092 Commercial Ave. Barrington, IL U.S.A. 60010-2392 (847) 381-4888 (847) 381-7053 (Fax) 800-962-7142 www.barnant.com e-mail: barnant@barnant.com A-1299-0766
More informationStandard Specifications
NARM, 2 Ways of Connection Small Size Pressure Gauge ø5mm Reverse flow function available on the standard model Space Saving -B2 NARM-6A-NG Standard Specifications Fluid Proof pressure psig (MPa) Max.
More informationBooster Regulator/Air Tank
Booster Regulator/Air Tank Increase factory air pressure by up to 4 times! Air-only operation requires no power supply, reduces heat generation, and Boost pressure allows easy installation. NEW Renewed
More informationHydraulic hand spindle pump Models CPP1000-M, CPP1000-L
Calibration Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L WIKA data sheet CT 91.05 for further approvals see page 2 Applications Calibration service companies and service industry Calibrations
More informationInstallation, Operation, and Maintenance Manual
Installation, Operation, and Maintenance Manual Welker The information in this manual has been carefully checked for accuracy and is intended to be used as a guide for the installation, operation, and
More information553 Series.
38467.03 www.caleffi.com Pre-adjustable filling units Copyright 01 Caleffi 3 Series Function The automatic filling valve is a device consisting of a pressure reducing valve with compensating seat, visual
More informationLocator Locator-D-Lux Air-Saver G1 Air-Saver G2
170663_air_saving_products 17-02-2011 16:42 Pagina 1 Locator Locator-D-Lux Air-Saver G1 Air-Saver G2 AIR SAVING PRODUCTS 170663_air_saving_products 17-02-2011 16:42 Pagina 2 170663_air_saving_products
More informationDescription Advanced Features Typical Applications
Series single stage, brass barstock line regulator Description Advanced Features Typical Applications The Series regulators are intended for secondary pressure control of noncorrosive, high purity or liquefied
More informationTEST SPECIFICATION NYT-909-C
748 Starbuck Ave, Watertown, NY 13601 Phone: +1-315-786-5200 Engineering Fax: +1-315-786-5673 TEST SPECIFICATION NYT-909-C CODE OF TESTS FOR TESTING "AB" TEST RACK P/N 702546 & 702612 ISSUE NO. 5 1.0 THE
More informationType N-10, N-11 Hazardous Area Non-incendive Transmitters
Electronic Pressure Catalog > Hazardous Area > N-10, N-11 Type N-10, N-11 Hazardous Area Non-incendive Transmitters Applications Natural gas compressors Wellhead monitoring Pipeline pressure General industrial
More informationSeries SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100
Clean Air Filter Variations SFD SFD SFD SFD Made to Order Type Disposable (non-replaceable element) Cartridge (replaceable element) Flow rate L/min (ANR) (at inlet pressure.7 MPa) Up to 6 Up to 8 Up to
More informationCash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified
Cash Valve PILOT OPERATED BACK PRESSURE VALVE ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 01 Certified KP HIGH CAPACITY PILOT OPERATED BACK PRESSURE VALVE DESCRIPTION The Cash Valve Type KP is a pilot
More information6000 SERIES OF PNEUMATIC DEADWEIGHT TESTERS
6000 SERIES OF PNEUMATIC DEADWEIGHT TESTERS USER MANUAL -1- SI-BARNET DEADWEIGHT TESTER 6000 SERIES Release: S31-0250 Revision: A Date: 05/08/03 MANUFACTURED BY: GE RUSKA RUSKA INSTRUMENT CORPORATION 10311
More informationCash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES. ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified
Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified TYPE G-4 DESCRIPTION FIG 2042 - Bronze FIG 2043 - Bronze
More informationS300 Series. Valve Link. Features. Fisher Controls
S0 Series Self-Operated Type VL FIELDVUE Regulators Valve Link Fisher Controls May 198 Bulletin 71.1:S0 The S0 Series self-operated, spring-loaded regulators are used for pressure-reducing control in a
More informationTECHNICAL DATA CAUTION
Page 1 of 6 1. DESCRIPTION The Viking Model D-2 Accelerator is a quick-opening device, with an integral anti-flood assembly, used to increase the operating speed of a differential type dry pipe valve.
More informationBUTTERFLY VALVES. Toll Free (877) - ICFLUID -2-
BUTTERFLY VALVES 1. General HyrdoWer is a globally recognized manufacturer of power unit accessories. They have become specialists in the design of Butterfly Valves and Hydraulic Compensators. The shut
More informationEASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:
2 Table Of Contents 1. Introduction 3 2. About this Manual 3 3. Contacting YZ Systems 3 4. Vessel Components 4 5. Specifications 5 6. Application 6 7. Theory of Operation 7 8. DuraSite Installation & Use
More informationHAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS
HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS Page 1 of 20 Page 2 of 20 TABLE OF CONTENTS Safety Warnings
More informationPrecision Pressure Regulators
hapter - Pressure Regulators Pressure range onnection thread Device Page 3 mm, high precision 0.0 2 / 8 bar G 1 8 RI.02 highly sensitive, max. 3 bar supply pressure 0.002 0.12 / 31 bar ¼"NPT R40.03 without
More informationPneumatic service kit Model CPG-KITP
Calibration technology Pneumatic service kit Model CPG-KITP WIKA data sheet CT 93.01 Applications Oil and gas industry Maintenance and service facilities Calibration service companies and service industry
More informationBL68 - Olympian Plus, plug-in system Filter/regulators and lubricators
>> Port size: 3/4... /2 (ISO G/ PTF) >> Complete air processing units pre-assembled, ready to install Technical features Medium: Compressed air only Maximum operating pressure: 7 bar (246 psi) Pressure
More informationDS05C,D,G Dial Set Pressure Regulating Valves
DS05C,D,G Dial Set Pressure Regulating Valves APPLICATION The Honeywell DS05C,D,G Dial Set Pressure Regulating Valve is a high quality pressure regulating valve that maintains a constant outlet pressure
More informationPrecision and Instrument Regulators 1/4" port size
Section 8 Precision and Instrument Regulators /" port size Contents -8 Precision Air Pressure Regulator /" ports............ale-8-2 R38 Instrument Regulator Aluminum Model /" ports.........ale-8- -8 R38
More informationDirect Operated Precision Regulator Modular Style. Standard Specifications
1 Direct Operated Precision Regulator Modular Style Series P3 Courtesy of Steven Engineering, Inc.-23 Ryan Way, South San Francisco, CA 948-637-Main Office: (65) 588-92-Outside Local Area: (8) 258-92-www.stevenengineering.com
More informationMEGR-1912 Instruction Manual
MEGR-1912 PRESSURE REGULATOR Instruction Manual- Look Inside For: Description Installation Start-Up Maintenance Parts Ordering Parts List Marshall Excelsior Company Marshall, MI 49068 269-789-6700 FAX
More informationV43 Pressure Actuated Water Regulating Valve
FANs 125, 121 Product/Technical Bulletin V43 Issue Date 0996 V43 Pressure Actuated Water Regulating Valve The V43 Pressure Actuated Water Regulating Valves are designed to regulate water flow for water-cooled
More informationCash Valve. Type G-4. Pilot Operated Pressure Reducing Regulator for Steam, Air and Gases. Flow Control
Cash Valve Type G-4 Pilot Operated Pressure Reducing Regulator for Steam, Air and Gases Issued - March 2001 CAVMC-0512-US-0609 ISO 9001 Certified Flow Control Description FIG 2042 - Bronze FIG 2043 - Bronze
More informationTHE PERFECT PRESSURE DROP TRAP PRIMER
THE PERFECT PRESSURE DROP TRAP PRIMER FIGURE NO. 2694 PATENT NO. 9,708,808 Regularly furnished in Lead-Free Brass as shown (back). Optional finishes available in Chrome (front), Nickel, or Stainless Steel
More informationInstruction Manual Contact Pressure Vacuum Gauge
MS10 Instruction Manual Contact Pressure Vacuum Gauge Table of Contents 1. Safety Instructions 2. Intended Applications 3. Product Description and Functions 4. Installation 5. Commissioning 6. Maintenance
More informationPressure transmitters EMP 2
Data sheet Pressure transmitters EMP 2 The high accuracy pressure transmitter EMP 2 is designed for monitoring and control in marine and industial applications and offers a reliable pressure measurement,
More informationNickel-Plated Brass Right Angle Flow Control Valves NPTF/Inch Series GSCU, GMCU, GSVU, GMVU, GSCO, GMCO
Nickel-Plated Brass Right Angle Flow Control Valves NPTF/Inch Series GSCU, GMCU, GSVU, GMVU, GSCO, GMCO Swivel Design : Meter-Out, Meter-In and Needle Orifice Tube Diameter OD: 1/8, 5/2, 1/4, 5/16, /8
More informationSpiratec ST14, ST16 and ST17 Sensor Chambers and sensors
0862050/1 IM-P086-18 MI Issue 1 Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors Installation and Maintenance Instructions 1. Safety Information 2. General product information 3. Installation 4.
More informationRS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.
RS(H)10,15 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to
More informationMEGR-1627 Instruction Manual
MEGR-1627 HIGH FLOW GAS REGULATOR Instruction Manual- Look Inside For: Description Installation Remote Vent Line Installations Startup and Adjustment Shutdown Maintenance Body Maintenance Procedures Diaphragm
More informationTechnical Data Sheet T 2025
Self-operated emperature Regulators emperature Regulator ype 4 Valve closes when the temperature rises. emperature Regulator ype 4u Valve opens when the temperature rises. Balanced single-seated globe
More informationSITRANS P measuring instruments for pressure
SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and
More informationSeries IRV1000/2000/3000
CAT.ES60-16 A Regulator Series /2000/3000 Allows adjustment of vacuum line pressure Regulator Series /2000/3000 3 sizes offered in the series Variations have been expanded to three sizes from only one
More informationTemperature Controllers
IM0004 April 2013 CONTENTS T-12 Thermostat PAGE Introduction 1 Scope 1 Description 1 Specification 1 Temperature Controllers 2 INTRODUCTION CAUTION Prior to installing, the instructions provided herein
More informationDiscontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.
Powers Controls RV 201 Pressure Reducing Valves Description Features Product Numbers Dual Pressure PRV Technical Instructions Document No. 155-049P25 RV 201-1 Single Pressure PRV The RV 201 Pressure Reducing
More informationFILTER, REGULATOR AND FILTER/REGULATOR Stainless Steel 316L Compact 1/4, High Flow 1/4-1/2
FILTER, REGULATOR AND FILTER/REGULATOR Stainless Steel L Compact /, High Flow / - / Air service equipment Series FEATURES Stainless Steel filter, regulator and filter regulator intended for corrosive environment
More informationPilot Check Valve: Metal Body Type
INFORMATION Pilot Check Valve: Metal Body Type The use of a metal body improves strength and environmental resistance. Temporary intermediate stops are possible. *1 *1 Precise intermediate stops are not
More informationPressure regulator for water
Pressure regulator for water rass version with VGW and international drinking water approvals Stainless steel version with VGW approval Compact plastic version Manometer port at pressure output The water
More informationD05 Pressure Regulating Valves
D05 Pressure Regulating Valves FEATURES PRODUCT DATA Noncorroding unitized cartridge contains all working parts and is easily replaceable. Includes built-in strainer and thermal bypass. Balanced seat construction
More informationType 1367 High-Pressure Instrument Supply System with Overpressure Protection
Instruction Manual D100343X012 Type 1367 November 2017 Type 1367 High-Pressure Instrument Supply System with Overpressure Protection TYPE 252 FILTER 2ND-STAGE TYPE 67CF FILTER-STYLE REGULATOR INLET TYPE
More informationBACK PRESSURE / SUSTAINING
In many liquid piping systems, it is vital that line pressure is maintained within relatively narrow limits. This is the function of the 108 Pressure Relief / Back Pressure Series of the OCV control valves.
More informationCAST IRON VALVES FLOAT VALVE
CAST IRON VALVES FLOAT VALVE NETAFIM CAST IRON VALVES FLOAT VALVE INLINE 25-400MM ANGLE 50-100MM SPECIFICATIONS Manufactured to ISO 9001 Available Valve sizes INLINE Flanged 50mm to 600mm & Threaded 19mm
More informationHigh Pressure Equipment Medium Pressure Valves, Fittings and Tubing
igh Pressure quipment Medium Pressure Valves, ittings and Tubing service igh Pressure quipment Company has developed a line of Medium Pressure products to assure safe and easy plumbing through. These needle
More informationHigh Pressure Equipment Taper Seal Valves, Fittings and Tubing
igh quipment Taper Seal Valves, ittings and Tubing 0,000 and,000 psi service igh quipment Company has developed the Taper Seal line of products to assure safe and easy plumbing through,000 psi. These needle
More informationHigh Pressure Equipment Medium Pressure Valves, Fittings and Tubing
igh Pressure quipment Medium Pressure Valves, ittings and Tubing service igh Pressure quipment Company has developed a line of Medium Pressure products to assure safe and easy plumbing through. These needle
More informationElectropneumatic Transducer (I/P) Installation, Operation and
Nitra NCP1 Series Electropneumatic Transducer (I/P) Installation, Operation and Maintenance Instructions Ordering Information Contents Part Number I/P Transducers Output Range Input psig bar Section Description
More informationBACK PRESSURE / SUSTAINING
SPECIFICATIONS DIMENSIONS In many liquid piping systems, it is vital that line pressure is maintained within relatively narrow limits. This is the function of the 108 Pressure Relief / Back Pressure Series
More informationDri-Line Mk3 Monnier Compressed Air Drain Trap
5044050/2 IM-P504-24 CH Issue 2 Dri-Line Mk3 Monnier Compressed Air Drain Trap Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation and Operation
More informationPneumatic retractable fitting for use with Unical 9000 and Uniclean 900 automated control systems
Pneumatic Retractable Fittings SensoGate WA 3 Pneumatic retractable fitting for use with Unical 9 and Uniclean 9 automated control systems Easy installation SensoGate WA 3 offers genuine plug & play. The
More informationWater Solenoids Safety Valves Air. Meters. Butterfly Ball Gate Globe Strainers Pressure Gauges Thermometers
Water Solenoids Safety Valves Air Valves Meters Butterfly Ball Gate Globe Strainers Pressure Gauges Thermometers Pneumatics Steam Traps Fire Hydrants Boiler Valves Water Metering Systems By combining high
More informationAIR SAVING PRODUCTS ADDING VALUE AIR-SAVER LOCATOR LOCATOR-EV
AIR SAVING PRODUCTS AIR-SAVER LOCATOR LOCATOR-EV ADDING VALUE REL LIABLE COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS Air saving products INDEX Chapter Content 1 Introduction to compressed
More informationTest pumps. Pressure sources. Good reasons for proper and reliable calibration
Test pumps Pressure is one of the most commonly measured quantities in engineering, which is why exact and reliable pressure measurement is especially important. However, the characteristics of the even
More informationVibration isolation system 1VIS10W. User manual
Vibration isolation system 1VIS10W User manual Standa 2014 Table of contents 1. General information 3 1.1. Introduction 3 1.1.1. Safety 5 1.2. Location of the table 5 1.3. Air supply requirements 5 2.
More informationVariable Area Flow Meters
Variable Area Flow Meters Over sixty years of variable area meter expertise Brooks started designing and manufacturing variable area (VA) meters, also referred to as rotameters, in 1946. Now, with more
More informationBIMBAR INFLATABLE PACKERS AND ACCESSORIES
BIMBAR INFLATABLE PACKERS AND ACCESSORIES Geopro supplies a complete range of inflatable packers in nine different diameters from 28 up to 170mm. All our packers made of BIMBAR rubber technology are reinforced
More informationPipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).
Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)
More informationMZX. Three-Port Seat Valves SPECIFICIATIONS AND GUIDE TO SELECTION
01 These seat valves are of globe construction with a linear moving spindle and a modified parabolic characterised plug operating against the upper seat which controls flow quantity to suit the load. The
More informationModel Series 62 Constant Differential Relay
Siemens Industry, Inc. INSTALLATION AND SERVICE INSTRUCTION INTRODUCTION Model Series 62 Constant Differential Relay Rev 11 March 2011 Supersedes Rev 10 The Constant Differential Relay maintains a constant
More informationprecision pipe fittings
Precision Pipe Fittings 1 8 to 1 sizes 316 stainless steel, brass, and exotic materials NPT threads HOKE PO Box 4866 Spartanburg, SC 29305-4866 Phone (864) 574-7966 Fax (864) 587-5608 www.hoke.com Sales-hoke@circor.com
More informationindd indd
122 Safety silencers 3 124-125 introduction 126-127 overview of our products 128-129 dimensioning guidelines 130-131 sizes 1/8 1/2 132-133 sizes 1 2 134-135 special silencers, accessories 136-137 applications
More informationVIC offers a variety of Calibrated Gas Leaks
CALIBRATED GAS LEAKS VIC offers a high quality line of calibrated gas leaks traceable to National Institute of Standards Technology (NIST). Calibrated gas leaks are used to provide a controlled delivery
More informationStorage Systems and Accessories
Storage Systems and Accessories High Pressure Air and Inert Gases 4500-6000 PSIG DOT and ASME Cylinders High Pressure Storage Systems If an application requires storage, either in the form of a single
More informationSpeed control assembly model A-1
Pressure Regulation 533a 1. DESCRIPTION The Viking Speed Control Assembly provides adjustment of the opening speed of Viking Deluge Valves, and adjustment of both the opening and closing speed of Viking
More informationPressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview
f gauge pressure Siemens AG 010 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection
More informationCode AWC20HP Air Compressor
Code 951816 AWC20HP Air Compressor Index of Contents Index of Contents 02 Declaration of Conformity 02 What s Included 03 Safety Precautions 03 Specifications (AWC20HP Air Compressor) 04 Assembly Instructions
More informationPressure gauges EN All stainless steel construction PBX100, PBX150 (1.18) Functional and constructive characteristics
Pressure gauges FT PBX 100-150-E-9.02 All stainless steel construction PBX100, PBX150 (1.18) EN 837-1 These instruments are designed for use in food, beverage, pharmaceutical, cryogenics, chemical and
More informationREFRIGERATION SYSTEM COMPONENTS
REFRIGERATION SYSTEM COMPONENTS henrytech.com Conventional Oil Separators The function of an Oil Separator is to remove oil from the discharge gas and return it to the Compressor either directly or through
More informationTypes S100K and S102K Pressure Regulators
Instruction Manual Form 5624 Types S0K and S2K 01/01 Types S0K and S2K Pressure Regulators W7478-1 Figure 1. Types S0K and S2K Pressure Regulator Introduction Scope of Manual This manual provides instructions
More informationModel PSI Compressor with 3-Gallon Air Tank 12VDC
Model 6350 150 PSI Compressor with 3-Gallon Air Tank 12VDC IMPORTANT: It is essential that you and any other operator of this product read and understandd the contents of this manual before installing
More information299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012
Installation Guide English September 2012 299H Series Introduction This Installation Guide provides instructions for installation, startup, and adjustment of 299H Series regulators. To receive a copy of
More informationAIR-SAVER G1 AIR-SAVER G2 LOCATOR-EV COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS AIR SAVING PRODUCTS
AIR-SAVER G1 AIR-SAVER G2 LOCATOR-EV ENVIRONMENT ADDING VALUE SAFEGUARD RELIABLE COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS AIR SAVING PRODUCTS Air saving products INDEX Chapter Content
More informationB84G - Excelon Plus Modular System General purpose filter/regulator
> Port size: 3/8" to 3/4" (PTF/ISO G) > Excelon Plus design allows in-line installation or modular installation with other Excelon Plus products > Push to lock adjusting knob with built in tamper resistant
More informationModel GP PRESSURE REDUCING VALVE Installation & Operation Manual
Model GP-2000 PRESSURE REDUCING VALVE Installation & Operation Manual Please read this bulletin thoroughly before using the pressure reducing valve, so that you may do so correctly and safely. Please carefully
More information42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)
42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) 42047 Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only) 45052 Constant Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor
More informationCASH VALVE TYPE KP BACK PRESSURE VALVES
A high capacity pilot operated back pressure valve that offers accurate control and dependable protection against overpressure conditions FEATURES Automatically maintains maximum pressure in a vessel or
More informationModel PRS-07i. Stainless Steel Low Pressure, In-Line Pressure Regulator (Reducing Valve)
Phone (toll-free): (888) 380-9660 Phone (local): (973) 340-9955 Fax: (973) 340-9933 Web: www.straval.com 21 Columbus Avenue Garfield, NJ 07026 Model PRS-07i Stainless Steel Low Pressure, In-Line Pressure
More information