1 Technical Information TI00436O/98/EN/7. Pressure Transmitter LC-M5, PPC-M5 Process Pressure Measurement Pressure transmitter with ceramic and metallic sensors, with analog electronics or communication via ART or PROFIBUS PA Application Absolute pressure and gauge pressure measurement in gases, steams or liquids in all areas of process engineering and process measurement technology Level, volume or mass measurements in liquids igh process temperature up to 30 C (66 F), for a maximum of 60 minutes 50 C (30 F) igh pressure up to 400 bar (6000 psi) International usage thanks to a wide range of approvals Your benefits Very good reproducibility and longterm stability igh reference accuracy: up to ±0.5 %, as PLATINUM version: ±0.075 % Turn down up to 00: End-to-end modularity for differential pressure, hydrostatics and pressure - replaceable display - universal electronics Easy commissioning without the need for an operating tool Easy and safe menu-guided operation - on-site via display module - via 4 mato0 ma with ART - via PROFIBUS PA Device versions compliant with ASME- BPE Used for process pressure monitoring up to SIL, certified to IEC 6508 Edition.0 and IEC 65 by TÜV NORD

2 With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and Services of the Electrical Industry, published by the Central Association of the Electrical Industry (Zentralverband Elektrotechnik und Elektroindustrie (ZVEI) e.v.) in its most recent version as well as the supplementary clause: "Expanded reservation of proprietorship".

3 Table of Contents Function and System Design Device selection Measuring principle Level measurement (level, volume and mass) Electrical differential pressure measurement with gauge pressure sensors System integration (except analog electronics) Communication protocol Input Measured variable Measuring range Explanation of terms Output Output signal Signal range Signal on alarm Load 4mAto0mA Analog and 4mAto0mA ART. Resolution Dead time, Time constant Dynamic behavior: current output (analog electronics)).. 3 Dynamic behavior: current output (ART electronics)... 3 Dynamic behavior: digital output (ART electronics) Dynamic behavior: PROFIBUS PA Damping Power Supply Electrical connection Supply voltage Start-up current ART Current consumption Cable entry Cable specification Residual ripple Influence of power supply Performance Characteristics General.. 8 Reference operating conditions Uncertainty of measurement for small absolute pressure ranges Long-term stability Influence of orientation Warm-up period Performance Characteristics Ceramic Process Isolating Diaphragm... 0 Reference accuracy PPC-M Total performance PPC-M Total error PPC-M Thermal change in the zero output and the output span PPC-M Performance Characteristics Metallic Process Isolating Diaphragm.... Reference accuracy LC-M Total performance LC-M Total error LC-M Thermal change in the zero output and the output span LC-M Operating conditions (installation) General installation instructions Measuring arrangement for devices without diaphragm seal PPC-M5, LC-M Wall and pipe mounting "Separate housing" version Oxygen applications PWIS cleaning Ultrapure gas applications Applications with hydrogen Operating Conditions (Environment) Ambient temperature range Storage temperature range Degree of protection Climate class Vibration resistance Electromagnetic compatibility Overvoltage protection (optional) Operating Conditions (Process) Process temperature range PPC-M Process temperature limits Pressure specifications Mechanical Construction F3 aluminum housing dimensions (I, J) F5 stainless steel housing dimensions (Q, R, S, hygienic) Process connections PPC-M5 (with ceramic process isolating diaphragm)... 3 Process connections LC-M5 (with metallic process isolating diaphragm)... 4 Wall and pipe mounting with mounting bracket Weight Material (not wetted) Material (wetted) uman Interface Operating elements Onsite operation Remote operation ardware and software for onsite and remote operation. 58 3

4 Table of Contents Planning Instructions for Diaphragm Seal Systems Applications Function and design Diaphragm seal filling oils Operating temperature range Installation instructions Certificates and Approvals CE mark Ex approvals Suitability for hygienic processes Functional safety SIL Marine approval CRN approval Pressure Equipment Directive (PED) Drinking water approval Standards and guidelines North-American practice for installation of process seals 64 Ordering Information Supplementary Documentation Technical Information Operating Instructions Brief Operating Instructions Functional safety manual (SIL) Safety instructions Installation/Control Drawings Accessories Shutoff valve Siphon Welding necks and Weld-in tool flanges Mounting bracket for wall and pipe mounting M connector Configuration Data Sheet (ART and PROFIBUS PA Electronics) Level Pressure Configuration Data Sheet (Analog Electronics) Pressure

5 Function and System Design Device selection Function and System Design PPC-M5 LC-M5 Field of application Process connections Measuring ranges With capacitive measuring cell and ceramic process isolating diaphragm Gauge pressure and absolute pressure Level Thread EN flanges DN 5 DN 80 ANSI flanges in to 4 in JIS flanges 50 A to 00 A Flush-mounted hygienic connections From -00/0 mbar to 00 mbar (-.5/0 psi to.5 psi) to -/0 bar to 40 bar (-5/0 psi to 600 psi) With piezoresistive measuring cell and metallic welded process isolating diaphragm Thread EN flanges DN 5 to DN 80 ANSI flanges in to 4 in JIS flanges 5 A to 00 A Prepared for diaphragm seal mount Flush-mounted hygienic connections From -400/0 mbar to 400 mbar (-6/0 psi to 6 psi) to -/0 bar to 400 bar (-5/0 psi to 6000 psi) OPL max. 60 bar (900 psi) max. 600 bar (9000 psi) Process temperature range -40 C.to +30 C (-40 F to +66 F), for a maximum of 60 minutes: +50 C (+30 F) Ambient temperature range Without LCD display: -40 C to +85 C (-40 F to +85 F) With LCD display: -0 C to +70 C (-4 F to +58 F) (extended temperature application range (-40 C to 85 C (-40 F to 85 F)) with restrictions in optical properties such as display speed and contrast) Separate housing: -0 C to +60 C (-4 F to +40 F) Reference accuracy Up to ±0.5 % of the set span PLATINUM version: up to ±0.075 % of the set span Supply voltage.5 V DC to 45 V DC (versions with plug-in connection 35 V DC) For intrinsically safe device versions:.5 V DC to 30 V DC Output 4mAto0mA, 4mAto0mA with superimposed ART protocol or PROFIBUS PA Options LC-M5: NACE-compliant materials PPC-M5, LC-M5: inspection certificate. or 3. or other certificates 3A approval and EEDG approval Specific firmware versions Initial device settings Separate housing Broad range of accessories Specialties Metal-free measurement with PVDF connection Special cleaning of the transmitter to remove paint-wetting substances, for use in paint shops Process connections with minimum oil volume Gas-tight, elastomer-free OPL: over pressure limit; depends on the lowest-rated element, with regard to pressure, of the selected components 5

6 Function and System Design Measuring principle Ceramic process isolating diaphragm used in PPC-M5 3 4 p Air pressure (gauge pressure sensors) Ceramic substrate 3 Electrodes 4 Ceramic process isolating diaphragm Metallic process isolating diaphragm used in LC-M5 3 4 p Silicon measuring element, substrate Wheatstone bridge 3 Channel with fill fluid 4 Metallic process isolating diaphragm Ceramic process isolating diaphragm used in PPC-M5 The ceramic sensor is a dry sensor, i. e. the process pressure acts directly on the robust ceramic process isolating diaphragm and deflects it. A pressure-dependent change in capacitance is measured at the electrodes of the ceramic substrate and the process isolating diaphragm. The measuring range is determined by the thickness of the ceramic process isolating diaphragm. Advantages: Guaranteed overload resistance up to 40 times the nominal pressure Thanks to ultrapure 99.9% ceramic extremely high chemical stability, comparable with Alloy C less relaxation high mechanical stability Can be used in absolute vacuum Outstanding surface finish, R a 0,3 µm (,8 µin) Metallic process isolating diaphragm used in LC-M5 The operating pressure deflects the process isolating diaphragm and a fill fluid transfers the pressure to a resistance bridge (semiconductor technology). The pressure-dependent change in the bridge output voltage is measured and evaluated. Advantages: Can be used for process pressure up to 400 bar (6000 psi) igh long-term stability Guaranteed overload resistance up to 4 times the nominal pressure Significantly less thermal effect compared to diaphragm seal systems 6

7 Function and System Design Level measurement (level, volume and mass) Function and design p h = ρ x g h Level measurement h eight (level) p Pressure r Density of the medium g Gravitation constant Your benefits Choice of different level measuring modes in the device software Volume and mass measurements in any tank shapes by means of a freely programmable characteristic curve Choice of diverse level units as a wide range of uses, even in the following cases in the event of foam formation in tanks with agitators or screen fittings in the event of liquid gases Electrical differential pressure measurement with gauge pressure sensors FXN 50 LC-M5 PPC-M5 Gateway Multidrop-Connector Shut-off valves e.g. filter In the example given, two pressure transmitters (each with a gauge pressure sensor) are interconnected. The pressure difference can thus be measured using two independent pressure transmitters. If using intrinsically safe devices, strict compliance with the rules for interconnecting intrinsically safe circuits as stipulated in IEC (proof of intrinsic safety) is mandatory. System integration (except analog electronics) The device can be fitted with a tag name and a preset bus address, see "Ordering Information" feature "Identification" version "O" and "P". 65 ff WARNING 7

8 Function and System Design Communication protocol 4 ma to 0 ma without communication protocol (analog electronics) 4 ma to 0 ma with ART communication protocol PROFIBUS PA Die Pepperl+Fuchs devices meet the requirements of the FISCO model. Due to the low current consumption of ma ± ma, the following number of devices can be operated on one bus segment if installing as per FISCO: - up to 8 pressure transmitters for Ex ia, CSA IS and FM IS applications - up to 3 pressure transmitters for all other applications, e. g. in non-hazardous areas, Ex na, etc. Further information on PROFIBUS PA can be found in the PNO Guideline. 8

9 Input Input Measured variable Analog electronics: Absolute pressure and gauge pressure ART electronics: Absolute pressure and gauge pressure, from which level (level, volume or mass) is derived Measuring range PPC-M5 with ceramic process isolating diaphragm for gauge pressure Nominal value Range limit Smallest calibratable span (preset at the factory MWP OPL 3 Vacuum resistance Version in the order code 4 lower (LRL) upper (URL) [bar (psi)] [bar (psi)] [bar (psi)] [bar (psi)] [bar (psi)] [bar abs (psi abs )] 00 mbar (.5 psi) -0. (-.5) +0. (+.5) 0.0 (0.5).7 (40.5) 4 (60) 0.7 (0.5) RA 50 mbar (3.75 psi) -0.5 (-3.75) +0.5 (+3.75) 0.0 (0.5) 3.3 (49.5) 5 (75) 0.5 (7.5) RC 400 mbar (6 psi) -0.4 (-6) +0.4 (+6) 0.0 (0.3) 5.3 (79.5) 8 (0) 0 RD bar (5 psi) - (-5) + (+5) 0.05 () 6.7 (00.5) 0 (50) 0 RA bar (30 psi) - (-5) + (+30) 0. (.5) (80) 8 (70) 0 RC 4 bar (60 psi) - (-5) +4 (+60) 0. (3) 6.7 (50.5) 5 (375) 0 RD 0 bar (50 psi) - (-5) +0 (+50) 0.5 (7.5) 6.7 (400.5) 40 (600) 0 R3A 40 bar (600 psi) - (-5) +40 (+600) (30) 40 (600) 60 (900) 0 R3D PPC-M5 with ceramic process isolating diaphragm for absolute pressure Nominal value Range limit Smallest calibratable span (preset at the factory MWP OPL 3 Vacuum resistance Version in the order code 4 lower (LRL) upper (URL) [bar (psi)] [bar (psi)] [bar (psi)] [bar abs (psi abs )] [bar abs (psi abs )] [bar abs (psi abs )] 00 mbar (5 psi) (+.5) 0.0 (0.5).7 (40.5) 4 (60) 0 AA 50 mbar (3.75 psi) (+3.75) 0.0 (0.5) 3.3 (49.5) 5 (75) 0 AC 400 mbar (6 psi) (+6) 0.0 (0.3) 5.3 (79.5) 8 (0) 0 AD bar (5 psi) 0 + (+5) 0.05 () 6.7 (00.5) 0 (50) 0 AA bar (30 psi) 0 + (+30) 0. (.5) (80) 8 (70) 0 AC 4 bar (60 psi) 0 +4 (+60) 0. (3) 6.7 (50.5) 5 (375) 0 AD 0 bar (50 psi) 0 +0 (+50) 0.5 (7.5) 6.7 (400.5) 40 (600) 0 A3A 40 bar (600 psi) (+600) (30) 40 (600) 60 (900) 0 A3D Recommended turn down: max 0:. Factory calibration turn down: max 0:, higher on request or configurable in the device. The MWP (maximum working pressure) for the measuring device depends on the lowest-rated element, with regard to pressure, of the selected components, i. e. the process connection ( 3 ff) has to be taken into consideration in addition to the measuring cell ( see table above). Pay attention to the pressure-temperature dependence also. For the appropriate standards and other information, see 3, "Pressure specifications" section. 3 OPL: over pressure limit depends on the lowest-rated element, with regard to pressure, of the selected components 4 Version in the order code see also 65 ff, feature "Sensor range" 9

10 Input LC-M5 with metallic process isolating diaphragm for gauge pressure Nominal value Range limit Smallest calibratable span (preset at the factory lower (LRL) upper (URL) MWP OPL 3 Vacuum resistance 4 Silicone oil/ Inert oil Version in the order code 5 [bar (psi)] [bar (psi)] [bar (psi)] [bar (psi)] [bar (psi)] [bar abs (psi abs )] 400 mbar (6 psi) -0.4 (-6) +0.4 (+6) 0.0 (0.3) 4 (60) 6 (90) 0.0/0.04 RD bar (5 psi) - (-5) + (+5) 0.05 () 6.7 (00) 0 (50) (0.5/0.6) RA bar (30 psi) - (-5) + (+30) 0. (.5) 3.3 (00) 0 (300) RC 4 bar (60 psi) - (-5) +4 (+60) 0. (3) 8.7 (80.5) 8 (40) RD 0 bar (50 psi) - (-5) +0 (+50) 0.5 (7.5) 6.7 (400.5) 40 (600) R3A 40 bar (600 psi) - (-5) +40 (+600) (30) 00 (500) 60 (400) R3D 00 bar (500 psi) - (-5) +00 (+500) 5 (75) 00 (500) 400 (6000) R4A 400 bar (6000 psi) - (-5) +400 (+6000) 0 (300) 400 (6000) 600 (9000) R4D LC-M5 with metallic process isolating diaphragm for absolute pressure Nominal value Range limit Smallest calibratable span (preset at the factory lower (LRL) upper (URL) MWP OPL 3 Vacuum resistance 4 Silicone oil/ Inert oil Version in the order code 5 [bar (psi)] [bar (psi)] [bar (psi)] [bar abs (psi abs )] [bar abs (psi abs )] [bar abs (psi abs )] 400 mbar (6 psi) (+6) 0.0 (0.3) 4 (60) 6 (90) 0.0/0.04 AD bar (5 psi) 0 + (+5) 0.05 () 6.7 (00) 0 (50) (0.5/0.6) AA bar (30 psi) 0 + (+30) 0. (.5) 3.3 (00) 0 (300) AC 4 bar (60 psi) 0 +4 (+60) 0. (3) 8.7 (80.5) 8 (40) AD 0 bar (50 psi) 0 +0 (+50) 0.5 (7.5) 6.7 (400.5) 40 (600) A3A 40 bar (600 psi) (+600) (30) 00 (500) 60 (400) A3D 00 bar (500 psi) (+500) 5 (75) 00 (500) 400 (6000) A4A 400 bar (6000 psi) (+6000) 0 (300) 400 (6000) 600 (9000) A4D Recommended turn down: max 0:. Factory calibration turn down: max 0:, higher on request or configurable in the device. The MWP (maximum working pressure) for the measuring device depends on the lowest-rated element, with regard to pressure, of the selected components, i. e. the process connection ( 3 ff) has to be taken into consideration in addition to the measuring cell ( see table above). Pay attention to the pressure-temperature dependence also. For the appropriate standards and other information, see 3, "Pressure specifications" section. 3 OPL: over pressure limit depends on the lowest-rated element, with regard to pressure, of the selected components 4 The vacuum resistance applies to the measuring cell at reference conditions. 5 Version in the order code see also 65 ff, feature "Sensor range" 0

11 Input Explanation of terms Explanation of terms: turn down (TD), set span and span based on zero point Case : Lower range value (LRV) Upper range value (URV) Example: Lower range value (LRV) = 0 bar Upper range value (URV) = 0.5 bar (7.5 psi) Nominal value (URL) = bar (5 psi) Turn down: TD = URL/ URV : Set span: URV LRV = 0.5 bar (7.5 psi) This span is based on the zero point. = LRL = LRV URV URL 0 bar 0.5 bar + bar Example: bar (5 psi) measuring cell = Case : Lower range value (LRV) Upper range value (URV) Example: Lower range value (LRV) = 0 bar Upper range value (URV) = 0.5 bar (7.5 psi) Nominal value (URL) = bar (5 psi) Turn down: TD = URL/ URV : Set span: URV LRV = 0.5 bar (7.5 psi) This span is based on the zero point. LRL LRV URV URL bar bar + bar Example: bar (5 psi) measuring cell = Case 3: Lower range value (LRV) Upper range value (URV) Example: Lower range value (LRV) = -0.6 bar (-9 psi) Upper range value (URV) = 0 bar Nominal value (URL) = bar (5 psi) Turn down: TD = URL/ LRV =.67: Set span: URV LRV = 0.6 bar (9 psi) This span is based on the zero point. = LRL LRV URV URL bar 0.6 bar 0 + bar Example: bar (5 psi) measuring cell Set span Span based on zero point 3 Nominal value i upper range limit (URL) 4 Nominal measuring range 5 Sensor measuring range LRL Lower range limit URL Upper range limit LRV Lower range value URV Upper range value

12 Output Output Output signal 4 ma to 0 ma analog, -wire 4 ma to 0 ma with superimposed digital communication protocol ART 6.0, -wire Digital communication signal PROFIBUS PA (Profile 3.0) Signal range Signal on alarm Load 4mAto0mA Analog and 4mAto0mA ART 4mA.to0mA Analog, 4mAto0mA ART: 3,8mAto0,5mA As per NAMUR NE43 4 ma to 0 ma Analog: Signal overshoot: > 0.5 ma Signal undershoot: < 3.8 ma Min Alarm (3.6 ma) 4 ma to 0 ma ART Options: Max. alarm: can be set from ma to 3 ma (factory setting: ma) old measured value: last measured value is held Min. alarm: 3.6 ma PROFIBUS PA: can be set in the Analog Input block, Options: Last Valid Out Value (factory setting), Fail-safe Value, Status Bad R Lmax [Ω] U [V] U.5 V RLmax 0.03 A Load diagram Power supply.5 V DC to 30 V DC for intrinsically safe device versions Power supply.5 V DC to 45 V DC (versions with plug-in connector 35 V DC) for other types of protection and for uncertified device versions R Lmax Maximum load resistance U Supply voltage When operating via a handheld terminal or via a PC with an operating program, a minimum communication resistance of 50 must be taken into account. Resolution Current output: A Display ART: can be set (factory setting: presentation of the maximum accuracy of the transmitter)

13 Output Dead time, Time constant I 00 % 90 % 63 % t t t 3 t Presentation of the dead time and the time constant Dynamic behavior: current output (analog electronics)) Type Dead time (t ) [ms] Time constant T63 (= t ) [ms] max. PPC-M Time constant T90 (= t 3 ) [ms] max. LC-M Dynamic behavior: current output (ART electronics) Type Dead time (t ) [ms] Time constant T63 (= t ) [ms] Time constant T90 (= t 3 ) [ms] max. PPC-M max. LC-M Dynamic behavior: digital output (ART electronics) Type Dead time (t ) [ms] Dead time (t ) [ms] + Time constant T63 (= t ) [ms] Dead time (t ) [ms] + Time constant T90 (= t 3 ) [ms] min PPC-M5 max min LC-M5 max Reading cycle Acyclic: max. 3/s, typical /s (depends on command # and number of preambles) Cyclic (Burst): max. 3/s, typical /s The pressure transmitter commands the BURST MODE function for cyclic value transmission via the ART communication protocol. Cycle time (Update time) Cyclic (Burst): min. 300 ms Response time Acyclic: min. 330 ms, typical 590 ms (depends on command # and number of preambles) Cyclic (Burst): min. 60 ms, typical 350 ms (depends on command # and number of preambles) 3

14 Output Dynamic behavior: PROFIBUS PA Type Dead time (t ) [ms] Dead time (t ) [ms] + Time constant T63 (= t ) [ms] Dead time (t ) [ms] + Time constant T90 (= t 3 ) [ms] min PPC-M5 max min LC-M5 max Reading cycle Cyclic: max. 30/s (dependent on the number and type of function blocks used in a closed-control loop) Acyclic: typical 5/s Cycle time (update time) min. 00 ms The cycle time in a bus segment in cyclic data communication depends on the number of devices, on the segment coupler used and on the internal PLC cycle time. Response time Cyclic: approx. 8 ms to 3 ms (depends on Min. Slave Interval) Acyclic: approx. 3 ms to 35 ms (depends on Min. Slave Interval) Damping A damping affects all outputs (output signal, display). Via on-site display, handheld terminal or PC with operating program, continuous from 0 s to 999 s Via DIP-switch on the electronic insert, switch position "on" (= set value) and "off" (= damping switched off) Factory setting: s 4

15 Power Supply Electrical connection Power Supply When using the measuring device in hazardous areas, installation must comply with the corresponding national standards and regulations and the Safety Instructions or Installation or Control Drawings ( 73, "Safety instructions" and "Installation/Control Drawings" sections). According to IEC/EN600 a suitable disconnector has to be installed for the device. ART: An overvoltage protection for the non-hazardous area, ATEX II () Ex ia IIC and IEC Ex ia can be ordered as an option ( 65 ff "Ordering Information" section). Protective circuits against reverse polarity, F influences and overvoltage peaks are installed. The digital communication signal is transmitted to the bus via a -wire connection. The bus also provides the power supply Electrical connection External grounding terminal Internal grounding terminal 3 Supply voltage ma to 0 ma for ART devices 5 For ART devices: With a handheld terminal, all the parameters can be configured anywhere along the bus line via menu operation. 6 Terminals 7 For ART devices: test terminals, see section "Taking 4 ma to 0 ma test signal" 4 ma to 0 ma Analog, 4 ma to 0 ma ART Taking 4 ma to 0 ma test signal A 4 ma to 0 ma test signal may be measured via the test terminals without interrupting the measurement. PROFIBUS PA For further information on the network structure and grounding, and for further bus system components such as bus cables, see the relevant documentation, e. g. the PNO Guideline. Cable specifications: Use a twisted, shielded two-wire cable, preferably cable type A For further information on the cable specifications, see PNO Guideline.09 and "PROFIBUS PA User and Installation Guideline" and IEC 658- (MBP). 5

16 + Pressure Transmitter LC-M5, PPC-M5 Power Supply Devices with valve connector Left Right electrical connection for devices with a valve connector view of the connector at the device Material: PA 6.6 Devices with arting plug an7d an7d Left Right electrical connection for devices with arting plug an7d view of the plug connector at the device Material: CuZn Connecting the cable version rd bk gnye + PE rd = red, bk = black, gnye = green-yellow ma 6

17 Power Supply Devices with M plug PIN assignment for M connector PIN Meaning 4 3 Signal + not assigned + nc 3 Signal 4 Earth P0075 Pepperl+Fuchs offers the following accessories for devices with an M plug: Plug-in jack M x, straight Material: body PA; coupling nut CuZn, nickel-plated Degree of protection (fully locked): IP66/67 Plug-in jack M x, elbowed Material: body PBT/PA; coupling nut GD-Zn, nickel-plated Degree of protection (fully locked): IP66/67 Cable 4x0.34 mm² (0 AWG) with M socket, elbowed, screw plug, length 5 m (6 ft) Material: body PUR; coupling nut CuSn/Ni; cable PVC Degree of protection (fully locked): IP66/67 Devices with 7/8 in plug PIN assignment for 7/8 in connector PIN Meaning 3 nc Signal Signal Shield 4 not assigned P0076 External thread: 7/8-6 UNC Material: housing/body CuZn, nickel-plated Protection: IP66/68 Cable gland Approval Type Clamping area Standard, II/G Ex ia, IS Plastic M0x.5 5 mm to 0 mm (0. in to 0.39 in) ATEX II/D, II/GD Ex ia, II3G Ex na Metal M0x.5 (Ex e) 7 mm to 0.5 mm (0.8 in to 0.4 in) Terminals For wire cross-sections 0,5 mm² to,5 mm² (0 AWG to 4 AWG) 7

18 Performance Characteristics General Supply voltage When using the measuring device in hazardous areas, installation must comply with the corresponding national standards and regulations and the Safety Instructions or Installation or Control Drawings. All explosion protection data are given in separate documentation which is available upon request. The Ex documentation is supplied as standard with all devices approved for use in explosion hazardous areas ( 73, "Safety instructions" and "Installation/Control Drawings" sections). 4 ma to 0 ma, 4 ma to 0 ma ART Type of protection Intrinsically safe Other types of protection Devices without certificate Supply voltage,5 V DC to 30 V DC,5 V DC to 45 V DC (versions with plug-in connection 35 V DC) PROFIBUS PA Version for non-hazardous areas: 9 V DC to 3 V DC Start-up current ART ma or ma (selectable) Current consumption PROFIBUS PA: ma ± ma, switch-on current corresponds to IEC 658-, Clause Cable entry 65 ff "Ordering Information", feature "Electrical connection". Cable specification Pepperl+Fuchs recommends using twisted, shielded two-wire cables. Terminals for wire cross-sections 0.5 mm to.5 mm (0 AWG to 4 AWG) Cable outer diameter: 5 mm to 9 mm (0. in to 0.35 in) depends on the used cable gland ( 7) Residual ripple Influence of power supply No influence on 4 ma to 0 ma signal up to ±5 % residual ripple within the permitted voltage range [according to ART hardware specification CF_SPEC-54 (DIN IEC 6038-) 0.00 % des URL/ V Performance Characteristics General Reference operating conditions Uncertainty of measurement for small absolute pressure ranges As per IEC Ambient temperature T a = constant, in the range of: + C to +33 C (+70 F to +9 F) umidity = constant, in the range of: 5 % to 80 % R Ambient pressure p a = constant, in the range of: 860 mbar to 060 mbar (.47 psi to 5.37 psi) Position of the measuring cell: constant, in range: ± horizontally Input of LOW SENSOR TRIM and IG SENSOR TRIM for lower range value and upper range value Span based on zero point Material of the process isolating diaphragm PPC-M5: Al O 3 (aluminum-oxide ceramic) Material of the process isolating diaphragm LC-M5: AISI 36L Filling oil LC-M5: silicone oil Supply voltage: 4 V DC ± 3 V DC Load with ART: 50 acc. to IEC The smallest expanded uncertainty of measurement that can be returned by our standards is: 0.4 % of the measured value in the range of mbar to 30 mbar % of the measured value in the range < mbar. 8

19 Performance Characteristics General Long-term stability PPC-M5 Measuring range Long-term stability of URL/ year With thread or flange bar (5 psi) ±0. % > bar (5 psi) ±0. % With hygienic process connection bar (5 psi) ±0.35 % > bar (5 psi) ±0. % LC-M5 Long-term stability of URL/ year Measuring range bar (5 psi) ±0.5 % > bar to 0 bar (5 psi to 50 psi) ±0. % 40 bar (600 psi) ±0. % 00 bar (500 psi) ±0. % 400 bar (6000 psi) ±0. % Influence of orientation Measuring error in mbar (psi) Axis of the diaphragm perpendicular Diaphragm points up 3 Diaphragm points down PPC-M5 LC-M5 with process connections / in thread and silicone oil LC-M5 with process connections > thread / in and flanges Calibration position, no measuring error < +0. mbar (0.003 psi) < -0. mbar (0.003 psi) < +4 mbar (0.06 psi) < -4 mbar (0.06 psi) < +0 mbar (0.45 psi) This value is doubled for inert oil. < -0 mbar (0.45 psi) This value is doubled for inert oil. Warm-up period 4 ma to 0 ma Analog:.5 s 4 ma to 0 ma ART: 5 s PROFIBUS PA: 8 s Position-dependent zero point shift can be corrected at the device. 5, "General installation instructions" section. 9

20 Performance Characteristics Ceramic Process Isolating Diaphragm Performance Characteristics Ceramic Process Isolating Diaphragm Reference accuracy PPC-M5 The reference accuracy comprises the non-linearity according to limit point setting, hysteresis and non-reproducibility as per IEC The data refer to the calibrated span. Gauge pressure sensors Measuring cell Standard reference accuracy Platinum reference accuracy 00 mbar (.5 psi) 50 mbar (3.75 psi), 400 mbar (6 psi), bar (5 psi), bar (30 psi), 4 bar (60 psi), 0 bar (50 psi) 40 bar (600 psi) TD : to TD 0: = 0.5 % TD > 0: to TD 0: = 0.0 % TD : to TD 0: = 0.5 % TD > 0: to TD 0: = 0.0 % TD : to TD 0: = 0.5 % TD > 0: to TD 0: = 0.0 % TD : to TD 0: = ±0.075 % TD > 0: to TD 0: = ± x TD TD : to TD 0: = ±0.075 % TD > 0: to TD 0: = ±0. % TD : to TD 0: = ±0.075 % TD > 0: to TD 0: = ± x TD Absolute pressure sensors Measuring cell Standard reference accuracy Platinum reference accuracy 00 mbar (.5 psi) 50 mbar (3.75 psi) 400 mbar (6 psi), bar (5 psi), bar (30 psi), 4 bar (60 psi), 0 bar (50 psi) 40 bar (600 psi) TD : to TD 0: = 0.5 % TD > 0: to TD 0: = ±0.005 x TD TD : to TD 0: = 0.5 % TD > 0: to TD 0: = 0.0 % TD : to TD 0: = 0.5 % TD > 0: to TD 0: = 0.0 % TD : to TD 0: = 0.5 % TD > 0: to TD 0: = 0.0 % TD : to TD 5: = ±0.075 % TD > 5: to TD 0: = ±0.05 x TD TD : to TD 0: = ±0.075 % TD > 0: to TD 3: = ±0. % TD : to TD 0: = ±0.075 % TD > 0: to TD 0: = ±0. % TD : to TD 0: = ±0.075 % TD > 0: to TD 0: = ± x TD Total performance PPC-M5 The "Total performance" specification comprises the non-linearity including hysteresis, nonreproducibility as well as the thermal change in the zero point. All specifications apply to the temperature range -0 C to +60 C (+4 F to +40 F) and Turndown :. Signal output Measuring cell % URL ART, PROFIBUS PA Analog (4 ma to 0 ma) 00 mbar (.5 psi), 50 mbar (3.75 psi), 400 mbar (6 psi) ±0.575 bar (5 psi), bar (30 psi), 4 bar (60 psi), 0 bar (50 psi), 40 bar (600 psi) ± mbar (.5 psi), 50 mbar (3.75 psi), 400 mbar (6 psi) ±0.775 bar (5 psi), bar (30 psi), 4 bar (60 psi), 0 bar (50 psi), 40 bar (600 psi) ±0.7 0

21 Performance Characteristics Ceramic Process Isolating Diaphragm Total error PPC-M5 The total error comprises the long-term stability and the total performance. All specifications apply to the temperature range -0 C to +60 C (+4 F to +40 F) and Turndown :. Signal output Measuring cell % URL year PPC-M5 with thread or flange ART, PROFIBUS PA Analog (4 ma to 0 ma) 00 mbar (.5 psi), 50 mbar (3.75 psi), 400 mbar (6 psi) ±0.55 bar (5 psi), bar (30 psi), 4 bar (60 psi), 0 bar (50 psi), 40 bar (600 psi) ± mbar (.5 psi), 50 mbar (3.75 psi), 400 mbar (6 psi) ±0.75 bar (5 psi), bar (30 psi), 4 bar (60 psi), 0 bar (50 psi), 40 bar (600 psi) ±0.67 PPC-M5with hygienic process connection ART, PROFIBUS PA Analog (4 ma to 0 ma) 00 mbar (.5 psi), 50 mbar (3.75 psi), 400 mbar (6 psi) ±0.95 bar (5 psi), bar (30 psi), 4 bar (60 psi), 0 bar (50 psi), 40 bar (600 psi) ± mbar (.5 psi), 50 mbar (3.75 psi), 400 mbar (6 psi) ±.5 bar (5 psi), bar (30 psi), 4 bar (60 psi), 0 bar (50 psi), 40 bar (600 psi) ±0.9 Thermal change in the PPC-M5 with thread or flange zero output and the output span PPC-M5 Signal output Measuring cell % of the calibrated measuring span -40 C to -0 C (-40 F to -4 F) -0 C to +60 C (+4 F to +40 F) -0 C to +00 C (-4 F to + F) ART, PROFIBUS PA Analog (4 ma to 0 ma) 00 mbar (.5 psi), 50 mbar (3.75 psi), 400 mbar (6 psi) x TD) x TD ( x TD) bar (5 psi), bar (30 psi), 4 bar (60 psi), 0 bar (50 psi), 40 bar (600 psi) x TD x TD ( x TD) 00 mbar (.5 psi), 50 mbar (3.75 psi), 400 mbar (6 psi) x TD) x TD x TD bar (5 psi), bar (30 psi), 4 bar (60 psi), 0 bar (50 psi), 40 bar (600 psi) x TD x TD x TD PPC-M5 with hygienic process connection Signal output Measuring cell % of the calibrated measuring span -0 C to +60 C (+4 F to +40 F) -0 C to +30 C (-4 F to +66 F) ART, PROFIBUS PA Analog (4 ma to 0 ma) 00 mbar (.5 psi), 50 mbar (3.75 psi), 400 mbar (6 psi) ( x TD) ( x TD) bar (5 psi), bar (30 psi), 4 bar (60 psi), 0 bar (50 psi), 40 bar (600 psi) ( x TD) ( x TD) 00 mbar (.5 psi), 50 mbar (3.75 psi), 400 mbar (6 psi) ( x TD) ( x TD) bar (5 psi), bar (30 psi), 4 bar (60 psi), 0 bar (50 psi), 40 bar (600 psi) ( x TD) ( x TD)

22 Performance Characteristics Metallic Process Isolating Diaphragm Performance Characteristics Metallic Process Isolating Diaphragm Reference accuracy LC-M5 The reference accuracy comprises the non-linearity according to limit point setting, hysteresis and non-reproducibility as per IEC The data refer to the calibrated span. Gauge pressure sensors/absolute pressure sensors LC-M5 without capillary Measuring cell Standard reference accuracy Platinum reference accuracy 400 mbar (6 psi) bar (5 psi) bar (30 psi) 4 bar (60 psi) 0 bar (50 psi), 40 bar (600 psi) 00 bar (500 psi) 400 bar (6000 psi) TD : = ±0.5 % TD > : to TD > 0: = ±0.5 % x TD with hygienic process connection: TD : = ±0.3 % TD > : to TD 0: = ±0.3 % x TD TD : to TD 5: = ±0.5 % TD > 5: to TD > 0: = ±0.03 % x TD with hygienic process connection: TD : = ±0.3 % TD > : to TD 0: = ±0.3 % x TD TD : to TD 0: = ±0.5 % TD > 0: to TD > 0: = ±0.05 % x TD with hygienic process connection: TD : to TD 5:: 0.5 % TD > 5: to TD 0:: 0. % TD : to TD 0: = ±0.5 % TD > 0: to TD 0: = ±0.0 % with hygienic process connection: TD : to TD 0:: 0.5 % TD > 0: to TD 0:: ±0. % TD : to TD 0: = ±0.5 % TD > 0: to TD 0: = ±0.0 % with hygienic process connection: TD : to TD 0:: 0.5 % TD > 0: to TD 0:: ±0. % TD : to TD 0: = ±0.5 % TD > 0: to TD 0: = ±0.0 % TD : to TD 5: = ±0.5 % TD > 5: to TD 0: = ±(0.03 % x TD) Not available with hygienic process connection: TD : = ±0. % TD > : to TD 0: = ±0. % x TD TD : to TD.5: = ±0.075 % TD >.5: to TD > 0: = ±0.03 % x TD with hygienic process connection: TD : = ±0. % TD > : to TD 0: = ±0. % x TD TD : to TD 5: = ±0.075 % TD > 5: to TD > 0: = ±0.05 % x TD with hygienic process connection: TD : to TD 5:: % TD > 5: to TD 0:: 0. % TD : to TD 0: = ±0.075 % TD 0: to TD 0: = ± % x TD with hygienic process connection: TD : to TD 0:: % TD > 5: to TD 0:: ±0. % TD : to TD 0: = ±0.075 % TD 0: to TD 0: = ±0. % with hygienic process connection: TD : to TD 0:: % TD > 5: to TD 0:: ±0. % TD : to TD 0: = ±0.075 % TD 0: to TD 0: = ± % x TD TD : to TD 5: = ±0.5 % TD > 5: to TD 0: = ±(0.03 % x TD) only LC-M5 with direct diaphragm seal mounting

23 Performance Characteristics Metallic Process Isolating Diaphragm Total performance LC-M5 The "Total performance" specification comprises the non-linearity including hysteresis, nonreproducibility as well as the thermal change in the zero point. All specifications apply to the temperature range -0 C to +60 C (+4 F to +40 F) and Turndown :. Signal output Messzelle LC-M5 LC-M5 with hygienic process connection LC-M5 with gold/rhodium-coated process isolating diaphragm % of URL 400 mbar (6 psi) ±0.34 ±0.34 ±.5 bar (5 psi) ±0.5 ±0.75 ART, PROFIBUS PA bar (30 psi) ±0.5 ± bar (60 psi) ±0.30 ±0.5 ±0.3 0 bar (50 psi), 40 bar (600 psi) ±0.5 ±0.5 ± bar (500 psi) ±0.5 ± bar (6000 psi) ±0.4 ± mbar (6 psi) ±0.34 ±0.54 ±.5 bar (5 psi) ±0.54 ±0.75 Analog (4 ma to 0 ma) bar (30 psi) ±0.45 ± bar (60 psi) ±0.30 ±0.45 ±0.3 0 bar (50 psi). 40 bar (600 psi) ±0.5 ±0.45 ± bar (500 psi) ±0.5 ± bar (6000 psi) ±0.4 ±0.4 Total error LC-M5 The total error comprises the long-term stability and the total performance. All specifications apply to the temperature range -0 C to +60 C (+4 F to +40 F) and Turndown :. Signal output Measuring cell % of URL/year 400 mbar (6 psi) ±0.59 ART, PROFIBUS PA bar to 40 bar (5 psi to 600 psi) ± bar to 00 bar (600 psi to 500 psi) ± bar (6000 psi) ± mbar (6 psi) ±0.79 Analog (4 ma to 0 ma) bar to 40 bar (5 psi to 600 psi) ± bar to 00 bar (600 psi to 500 psi) ± bar (6000 psi) ±0.5 Thermal change in the zero output and the output span LC-M5 LC-M5 (basic device) Measuring cell -0 C to +60 C (+4 F to +40 F) -40 C to -0 C, +60 C to +85 C (-40 F to +4 F, +40 F to +85 F) % of the calibrated measuring span 400 mbar (6 psi), bar (5 psi), bar (30 psi), 4 bar (60 psi), 0 bar (50 psi), 40 bar (600 psi), 00 bar (500 psi) ±( x TD) ±( x TD) 400 bar (6000 psi) ±( x TD) ±( x TD) 3

24 Performance Characteristics Metallic Process Isolating Diaphragm LC-M5 with hygienic process connection Signal output Measuring range -0 C to +60 C (+4 F to +40 F) -40 C to -0 C, +60 C to +5 C (-40 F to +4 F, +40 F to +57 F) % of the calibrated measuring span Clamp / in/400 mbar (6 psi) ±( x TD) ±( x TD) ART, PROFIBUS PA 400 mbar (6 psi), bar (5 psi) ±( x TD) ±(0. +. x TD) bar (30 psi), 4 bar (60 psi), 0 bar (50 psi), 40 bar (600 psi) ±( x TD) ±( x TD) Clamp / in/400 mbar (6 psi) ±( x TD) ±(. +.5 x TD) Analog (4 ma to 0 ma) 400 mbar (6 psi), bar (5 psi) ±( x TD) ±( x TD) bar (30 psi), 4 bar (60 psi), 0 bar (50 psi), 40 bar (600 psi) ±( x TD) ±( x TD) 4

25 Operating conditions (installation) Operating conditions (installation) General installation instructions Measuring arrangement for devices without diaphragm seal PPC-M5, LC-M5 The position-dependent zero point shift can be corrected: directly at the device via operating keys on the electronic insert directly at the device via operating keys on the display (except analog electronics) via digital communication if the cover is not open (except analog electronics) In hazardous areas, comply strictly with the safety instructions when the housing cover is closed and open. Pepperl+Fuchs offers a mounting bracket for installing the device on pipes or walls. See also 5, "Wall and pipe mounting" section. Use flushing rings for flange and cell diaphragm seals if medium buildup or clogging can be expected at the diaphragm seal connection. The flushing ring can be inserted between the process connection and the diaphragm seal. Thanks to the two lateral flushing bore holes, material buildup in front of the process isolating diaphragm can be rinsed away and the pressure chamber can be ventilated. To guarantee the leak-tightness of the transmitter, Pepperl+Fuchs recommends that only genuine cable glands be used (also available as spare parts). Pressure transmitters without diaphragm seals are mounted as per the norms for a manometer (DIN EN 837-). We recommend the use of shutoff devices and siphons. The orientation depends on the measuring application. Pressure measurement in gases Mount pressure transmitter with shutoff device above the tapping point so that any condensate can flow into the process. Pressure measurement in steams Mount pressure transmitter with siphon above the tapping point. Fill the siphon with liquid before commissioning. The siphon reduces the temperature to almost the ambient temperature. Pressure measurement in liquids Mount pressure transmitter with shutoff device below or at the same level as the tapping point. Level measurement Mount pressure transmitter below the lowest measuring point (zero point of the measurement). Do not mount the device at the following positions: In the filling curtain, in the tank outlet or at a point in the container which could be affected by pressure pulses from an agitator or a pump. The calibration and functional test can be carried out more easily if you mount the device downstream of a shutoff device. Wall and pipe mounting "Separate housing" version For installing the device on pipes or walls, Pepperl+Fuchs provides a mounting bracket which is included in the scope of supply or can be ordered as a separate accessory. For the dimensions, see 49. With the "separate housing" version, you are able to mount the housing with the electronics insert at a distance from the measuring point. This version allows for trouble-free measurement: Under particularly difficult measuring conditions (at installation locations that are cramped or difficult to access) If extreme cleaning of the measuring point is required If the measuring point is exposed to vibrations For space-saving installations You can choose between different cable versions: PE ( m (6.6 ft), 5 m (6 ft) and 0 m (33 ft)) FEP (5 m (6 ft)). 65 ff "Ordering Information", feature "Separate housing" For the dimensions, 49. 5

26 Operating conditions (installation) 4 FEP cable: IP69K IP66/68 NEMA 4/6P PE cable: IP66/68 NEMA 4/6P 3 IPXX (see section Ordering Information ) r 0 mm Process connection with sensor Cable, both ends are fitted with a socket 3 Mounting bracket provided, suitable for pipe and wall mounting (for pipes from -/4 in up to in diameter) 4 ousing with electronic insert In the case of the "separate housing" version, the sensor is delivered with the process connection and cable ready mounted. The housing and a mounting bracket are enclosed as separate units. The cable is provided with a socket at both ends. These sockets are simply connected to the housing and the sensor. Degree of protection for the process connection and sensor with the use of FEP cable: IP69K IP66 NEMA 4/6P IP68 (.83 m O for 4 h) NEMA 4/6P PE cable: IP66 NEMA 4/6P IP68 (.83 m O for 4 h) NEMA 4/6P Technical data of the PE and FEP cable: Minimum bending radius: 0 mm (4.7 in) Cable extraction force: max. 450 N (0 lbf) Resistance to UV light Use in hazardous area: Intrinsically safe installations (Ex ia/is) FM/CSA IS: for Div. installation only Reduction in installation height If the separate housing is used, the mounting height of the process connection is reduced compared to the dimensions of the standard version (see graphic). r 0 mm r 0 mm r 0 mm F3 F ø54. ➀ 9 ➀ 7 ➀ 8 6

27 Operating conditions (installation) Oxygen applications Oxygen and other gases can react explosively to oils, grease and plastics. As a result, the following are some of the precautions that must be taken: All components of the system, such as measuring devices, must be cleaned in accordance with the BAM (DIN 947) requirements. Depending on the materials used, a certain maximum temperature and maximum pressure must not be exceeded for oxygen applications. The devices suitable for gaseous oxygen applications are listed in the following table with the specification p max. Ordering code for devices, cleaned for oxygen applications PPC-M5 devices with sensors, nominal value < 0 bar (50 psi) p max for oxygen applications Over pressure limit (OPL) of sensor, 3 T max for oxygen applications 60 C (40 F) PPC-M5 devices with sensors, nominal value 0 bar (50 psi) 40 bar (600 psi) 60 C (40 F) LC-M5 Depends on the lowest-rated element, with regard to pressure, of the selected components: over pressure limit (OPL) of sensor 3, process connection (.5 x PN) or fill fluid (60 bar (30 psi)) 85 C (85 F) Only device, not accessory or enclosed accessory. 65 ff "Ordering Information", feature "Sensor range" 3 PPC-M5 with PVDF thread or PVDF flange p max = 5 bar (5 psi) PWIS cleaning Ultrapure gas applications Applications with hydrogen Special cleaning of the transmitter to remove paint-wetting substances, for use in paint shops. Pepperl+Fuchs also provides devices which have been cleaned of oil and grease for special applications, such as for ultrapure gas. No special restrictions regarding the process conditions apply to these devices. 65 ff "Ordering Information", feature "Service", version "F". With regard to materials in which hydrogen formation takes place, hydrogen atoms can diffuse through the metallic process isolating diaphragm. This can result in incorrect measurement results. Pepperl+Fuchs offers process isolating diaphragms with a gold/rhodium coating for such instances. 65 ff "Ordering Information", feature "Material of the process isolating diaphragm", version "A". 7

28 Operating Conditions (Environment) Operating Conditions (Environment) Ambient temperature range Version Without LCD display With LCD display With M plug, elbowed With separate housing -40 C to +85 C (-40 F to +85 F) -0 C to +70 C (-4 F to +58 F) -5 C to +85 C (-3 F to +85 F) -0 C to +60 C (-4 F to +40 F) (installation without insulation) Extended temperature application range (-40 C to +85 C (-40 F to +85 F)) with restrictions in optical properties such as display speed and contrast For devices for use in hazardous areas, see Safety Instructions, Installation or Control Drawing. ( 73 ff, "Safety instructions" and "Installation/Control Drawings" sections). Storage temperature range Version Without LCD display With LCD display With M plug, elbowed With separate housing -40 C to +90 C (-40 F to +94 F) -40 C to +85 C (-40 F to +85 F) -5 C to +85 C (-3 F to +85 F) -40 C to +60 C (-40 F to +40 F) Degree of protection 65 ff "Ordering Information", feature "Electrical connection". Separate housing ( 5) Climate class Class 4K4 (air temperature: -0 C to 55 C (-4 F to +3 F), relative humidity: 4 % to 00 %) satisfied as per DIN EN (condensation possible). Vibration resistance Device/accessory Test standard Vibration resistance Devices without mounting bracket Devices with mounting bracket GL VI-7- Part 7: Guidelines for the Performance of Type Approvals Chapter : Test Requirements for Electrical/Electronic Equipment and Systems IEC IEC IEC IEC guaranteed for 5 z to 5 z: ±.6 mm (0.06 in); 5 z to 00 z: 4 g in all 3 planes guaranteed for 0 z to 60 z: ±0.35 mm (0.0 in); 60 z to 000 z: g in all 3 planes guaranteed for 0 z to 60 z: ±0.5 mm (0.0 in); 60 z to 500 z: g in all 3 planes For high-vibration applications, a device with a separate housing can be used. We recommend a suitable bracket for mounting (see "Wall and pipe mounting" section on 5) Electromagnetic compatibility Electromagnetic compatibility as per all the relevant requirements of the EN 636 series and NAMUR Recommendation EMC (NE). Details can be found in the Declaration of Conformity (in the download area of " Maximum deviation: < 0.5 % of span 8

29 Operating Conditions (Environment) Overvoltage protection (optional) The device can be fitted with overvoltage protection. The overvoltage protection is mounted at the factory on the housing thread (M0x.5) for the cable gland and is approx. 70 mm (.76 in) in length (take additional length into account when installing). The device is connected as illustrated in the following graphic. Incoming connection cables + - Unit to be protected + - Red Black + - Connection cables Shield grounding without direct Overvoltage protection 9

30 Operating Conditions (Process) Operating Conditions (Process) Process temperature range PPC-M5 T a T p T p C T a C T a = Ambient temperature; T p = Process temperature;, and 3 see following chapter. Process temperature limits PPC-M5 (with ceramic process isolating diaphragm) 3: -40 C to +00 C (-40 F to + F) for threaded process connections or flange process connections : -40 Cto+30 C (-40 Fto+66 F) for hygienic process connections : For a maximum of 60 minutes: +50 C (+30 F) Observe the process temperature range of the seal. See also the following table. Version for feature "Seal material" in the order code Seal Notes Process temperature range Thread or flange ygienic process connection A FKM Viton -0 C to +00 C (-4 F to + F) A FKM Viton cleaned for O application -5 C to +60 C (+3 F to +40 F) B FKM Viton FDA, 3A Class I, USP Class VI -5 C to +00 C (+3 F to + F) F NBR FDA -0 C to +00 C (-4 F to + F) -5 C to +50 C (+3 F to +30 F) NBR, low temperature -40 C to +00 C (-40 F to + F) G NBR FDA, 3A Class I, KTW, AFNOR, BAM -5 C to +00 C (-3 F to + F) J EPDM 70 FDA -40 C to +00 C (-40 F to + F) -0 C to +5 C (-4 F to +57 F) K EPDM 9 FDA, 3A Class II, USP Class VI, DVGW, KTW, W70, WRAS, ACS, NSF6-5 C to +50 C (+5 F to +30 F) L FFKM Kalrez C to +00 C (+4 F to + F) M FFKM Kalrez C to +00 C (+4 F to + F) N FFKM Kalrez 6 FDA, USP Class VI -5 C to +00 C (+3 F to + F) P Fluoroprene XP40 FDA, USP Class VI, 3A Class I +5 C to +00 C (+4 F to + F) S VMQ Silicone FDA -35 C to +85 C (-3 F to +85 F) -5 C to +50 C (+3 F to +30 F) +5 C to +50 C (+4 F to +30 F) -0 C to +85 C (-4 F to +85 F) Suitable for foods FDA CFR

31 Operating Conditions (Process) Applications with jumps in temperature Extreme jumps in temperature can result in temporary measuring errors. Temperature compensation takes effect after several minutes. Internal temperature compensation is faster the smaller the jump in temperature and the longer the time interval involved. For further information please contact your local Pepperl+Fuchs Sales Center. LC-M5 (with metallic process isolating diaphragm) Description Process connections with internal process isolating diaphragm Process connections with flush-mounted process isolating diaphragm, GA, G-/A, GA, NPT, -/NPT, NPT, M44x.5, EN/DIN, ANSI and JIS flanges Process connections with flush-mounted process isolating diaphragm, G/A, M0x.5 ygienic process connections Temperature operating range -40 C to +5 C (-40 F to +57 F) -40 C to +00 C (-40 F to + F) -0 C to +85 C (-4 F to +85 F) -40 C to +30 C (-40 F to +66 F) For a maximum of 60 minutes: +50 C (+30 F) Pressure specifications The maximum pressure for the measuring device depends on the lowest-rated element with regard to pressure. See the following sections: 9, "Measuring range" section "Mechanical Construction" chapter. The MWP (maximum working pressure) is specified on the nameplate. This value refers to a reference temperature of +0 C (68 F), or 00 F (38 C) for ANSI flanges, and may be applied to the device for an unlimited time. Observe temperature dependency of the MWP. The pressure values permitted at higher temperatures can be found in the following standards: EN 09-: 00 Tab. 8 ASME B 6.5a 998 Tab. -. F36 ASME B 6.5a 998 Tab..3.8 N076 JIS B 0. The test pressure corresponds to the over pressure limit of the device (over pressure limit OPL =.5 x MWP ) and may be applied for only a limited time period in order to avoid permanent damage. The Pressure Equipment Directive (EC Directive 97/3/EC) uses the abbreviation "PS". The abbreviation "PS" corresponds to the MWP (maximum working pressure) of the measuring device. In the case of sensor range and process connection combinations where the OPL (over pressure limit) of the process connection is smaller than the nominal value of the sensor, the device is set at the factory, at the very maximum, to the OPL value of the process connection. If you want to use the entire sensor range, select a process connection with a higher OPL value (.5 x PN; PN = MWP). In oxygen applications, the values for "p max and T max for oxygen applications" as per 7, "Oxygen applications" section may not be exceeded. Avoid steam hammering! Steam hammering can cause zero point drift. Recommendation: Residue (such as condensation or drops of water) can remain at the process isolating diaphragm after CIP cleaning and lead to local steam hammering if immediately steam is introduced. In practice, drying the process isolating diaphragm (e. g. by blowing off excess moisture) has proven to be a successful way of avoiding steam hammering. With regard to their stability-temperature property, the materials.4435 and.4404 are grouped together under 3EO in EN 09- Tab. 8. The chemical composition of the two materials can be identical. The equation does not apply for LC-M5 with a 40 bar (600 psi) or a 00 bar (500 psi) measuring cell. 3

32 Mechanical Construction Mechanical Construction F3 aluminum housing dimensions (I, J) 5 94 Front view, left-hand side view, top view The cover with viewing window is 5 mm (0.59 in) higher than the cover without viewing window. For installation height for housing with viewing window, see the specific process connection. ousing weight 49. F5 stainless steel housing dimensions (Q, R, S, hygienic) Front view, top view. The cover with viewing window is 9 mm (0.75 in) higher than the cover without viewing window. For installation height for housing with viewing window, see the specific process connection. ousing weight 49. Process connections PPC-M5 (with ceramic process isolating diaphragm) Thread, internal process isolating diaphragm Process connections PPC-M5, thread ISO 8 Installation height 33. Thread ISO 8 G/ A EN 837; Material version G: AISI 36L, version GC: Alloy C76 Version GV: PVDF (max.: 5 bar (7,5 psi), -0 C to +60 C (+4 F to +40 F)), Version GV mount version with a mounting bracket only ( 5); weight: 0.63 kg (.39 lbs) Thread ISO 8 G/A G/4 (female); Material version G4: AISI 36L, version G3: Alloy C76; weight: 0.63 kg (.39 lbs) 3 Thread ISO 8 G/A hole.4 mm (0.45 in); Material version GM: AISI 36L, version GN: Alloy C76; weight: 0.63 kg (.39 lbs) G/A G/A G/4 3 G/A.4 mm ø ø3 ø6 G / 3 G /4 ø7.5 G / ø.4 ø7.5 G / 3

33 Mechanical Construction / MNPT /4 FNPT / MNPT.4 mm / MNPT 3 mm 3 4 / FNPT ø.4 /4 NPT / NPT ø.4 / NPT ø3 / NPT ø6.5 / NPT Process connections PPC-M5, thread ANSI Installation height 33. Thread ANSI /MNPT /4FNPT; Material version RLJ: AISI 36L, version RLC: Alloy C76; weight: 0.63 kg (.39 lbs) Thread ANSI /MNPT hole.4 mm (0.45 in); Material version RKJ: AISI 36L; version RKC: Alloy C76; weight: 0.63 kg (.39 lbs) 3 Thread ANSI /MNPT hole 3 mm (0. in); Material version RJF: PVDF (max.: 5 bar (5) psi, -0 C to +60 C (+4 F to +40 F)) mount version with a mounting bracket only ( 5); weight: 0.63 kg (.39 lbs) 4 Thread ANSI /FNPT Material version RJ: AISI 36L, version RC: Alloy C76; weight: 0.63 kg (.39 lbs) Process connections PPC-M5, thread JIS Installation height 33. Version J3: thread JIS B00 G/ (male), Material: AISI 36L; weight: 0.63 kg (.39 lbs) Version J3: thread JIS B003 R/ (male), Material: AISI 36L; weight: 0.63 kg (.39 lbs) Installation height for devices with threaded connection and internal process isolating diaphragm F3 housing (I, J) F5 housing (Q, R, S) eight 54 mm (6.06 in) 46 mm (5.75 in) G/ R/ ø8 ø3 ø5 0 3 G / 3. 3 ø.4 R / 33

34 Mechanical Construction Process connections PPC-M5 (with ceramic process isolating diaphragm) continued Thread, flush-mounted process isolating diaphragm G-/ SW AF G SW AF G / ø55 SW 60 SW 60 SW AF 60 AF 60 AF Process connections PPC-M5, Installation height see table below. Thread ISO 8 G-/A; Material version G5: AISI 36L; weight: 0.63 kg (.39 lbs) Thread ISO 8 GA; Material version G6: AISI 36L; weight: 0.63 kg (.39 lbs) 3 Thread ANSI -/MNPT; Material version N5: AISI 36L; weight: 0.63 kg (.39 lbs) 4 Thread ANSI MNPT; Material version N6: AISI 36L; weight: 0.63 kg (.39 lbs) 5 Thread DIN 3 M 44x,5; Material version G44: AISI 36L; weight: 0.63 kg (.39 lbs) Installation height for devices with threaded connection and flush-mounted process isolating diaphragm F3 housing (I, J) F5 housing (Q, R, S) eight 0 mm (7.9 in) 93 mm (7.6 in) G ø68 -/NPT NPT M44x / NPT NPT ø68 ø40.5 M44x.5 34

35 Mechanical Construction Process connections PPC-M5 (with ceramic process isolating diaphragm) continued EN/DIN flanges, connection dimensions as per EN 09-/DIN 57 g k D Process connections PPC-M5, EN/DIN flange with raised face (flush-mounted process isolating diaphragm) Installation height 37. b 6 (.04) g Flange Boltholes Version Material Nominal Diameter Nominal pressure Shape Diameter Thickness Raised face Quantity Diameter ole circle Flange weight D b g g k [mm] [mm] [mm] [mm] [mm] [kg] F45 AISI 36L DN5 PN0-40 B (D) F55 AISI 36L DN3 PN0-40 B (D) F65 AISI 36L DN40 PN0-40 B (D) F6 ECTFE 4 DN40 PN0-40 B (D) F75 AISI 36L DN50 PN0-40 B (D) F7 PVDF 3 DN50 PN0-6 B (D) F7 ECTFE 4 DN50 PN5-40 B (D) F95 AISI 36L DN80 PN0-40 B (D) F9 ECTFE 4 DN80 PN5-40 B (D) Designation as per DIN 57 in brackets ousing weight 49 3 OPL.: 5 bar (5 psi), Process temperature range: -0 C to +60 C (+4 F to +40 F) 4 ECTFE coating on AISI 36L (.4404). When operating in hazardous areas, avoid electrostatic charging of the plastic surfaces. 35

36 Mechanical Construction Process connections PPC-M5 (with ceramic process isolating diaphragm) continued ANSI flanges, connection dimensions as per ANSI B 6.5, raised face RF g k D Process connections PPC-M5, AANSI flange with raised face RF (flush-mounted process isolating diaphragm) Installation height 37. b g Flange Version Material Nominal diameter Class Diameter Thickness Raised face Boltholes Quantity Diameter ole circle Flange weight [in] [lb./ sq.in] D b g g k [in]/[mm] [in]/[mm] [in]/[mm] [in]/[mm] [in]/[mm] [kg] A3 AISI 36/36L / /4. / /5.7 3./ A3 AISI 36/36L / /7. / /9 3.5/ A5 AISI 36/36L -/ 50 5/7 0.69/7.5.88/ / / A5 AISI 36/36L -/ / /0.6.88/ /.4 4.5/4.3.6 A6 AISI 36/36L 50 6/ /9. 3.6/ / /0.7.4 A6 ECTFE / /9. 3.6/ / /0.7.4 A6V PVDF / /9. 3.6/ / / A6 AISI 36/36L / /.4 3.6/ /9. 5/7 3. A8 AISI 36/36L / /3.9 5/ /9. 6/ A8 ECTFE / /3.9 5/ /9. 6/ A8V PVDF / /3.9 5/ /9. 6/ A8 AISI 36/36L /09.5./8.6 5/ /.4 6.6/ A9 AISI 36/36L / / / /9. 7.5/ A9 ECTFE / / / /9. 7.5/ A9 AISI 36/36L /54.5/ / / /00..6 ousing weight 49 Combination of AISI 36 for required pressure resistance and AISI 36L for required chemical resistance (dual rated) 3 ECTFE coating on AISI 36L (.4404). When operating in hazardous areas, avoid electrostatic charging of the plastic surfaces. 4 OPL.: 5 bar (5 psi), Process temperature range: -0 C to +60 C (+4 F to +40 F) 36

37 Mechanical Construction Process connections PPC-M5 (with ceramic process isolating diaphragm) continued JIS flanges, connection dimensions as per JIS B 0 BL, raised face RF g g k D Process connections PPC-M5, JIS flange with raised face RF (flush-mounted process isolating diaphragm), material: AISI 36L Installation height see table below. Process connections PPC-M5 (with ceramic process isolating diaphragm) - continued Installation height for devices with flange b Flange Boltholes Version Nominal diameter Nominal pressure Diameter Thickness Raised face Quantity Diameter ole circle Flange weight D b g g k [mm] [mm] [mm] [mm] [mm] [kg] J6 50A 0 K J7 80A 0 K J9 00A 0 K ousing weight 49 F3 housing (I, J) F5 housing (Q, R, S) eight 0 mm (7.9 in) 93 mm (7.6 in) 37

38 Mechanical Construction Process connections PPC-M5 (with ceramic process isolating diaphragm) continued ygienic process connection, flush-mounted process isolating diaphragm DIN 85 DN40 D4 K DIN 85 DN50 D D K D3 DIN 864 DN40 D4 K D D K 7.5 (0.3) D D3 mm (in) ygienic process connections, material: AISI 36L (.4435); Delta ferrite content < % Surface roughness of the surfaces in contact with the medium R a 0.76 µm (30 µin). 0 (0.39) (0.43) D3 D D K Tri-Clamp 3 in D K 7 (0.8) 0 (0.39) (0.43) 7.5 (0.3) D3 D D 3 4 DIN 864 DN50 5 Tri-Clamp in 6 D3 d D D3 d D Pos. Version Nominal pressure PN Outer D Outer D Internal D3 Outer D4 Seal d ole circle K eight Weight [kg/lbs] M (.) 48 (.89) 38 (.5) 60 (.36) 5 (.05) 0.65 (.44) M (.68) 6 (.4) 4 (.65) 5 (.05) 0.76 (0.6) 3 4 M64 M (.6) 66.8 (.63) 48 (.89) 6 (.4) 38 (.5) 4 (.65) 60 (.36) 5 (.05) 5 (.05) max. 0 (8.66) (.45) 0.88 (0.64) 5 T (.5) 6 (.4) 4 (.65) 56.5 (.) 5 (.05) 0.7 (0.38) 6 T (3.58) 76.7 (3.0) 4 (.65) 83.5 (3.9) 5 (.05) (.9) mm (in) 4 x M5 thread 38

39 Pressure Transmitter LC-M5, PPC-M5 Mechanical Construction Varivent F DN5-3 Varivent N DN40-6 D K D D K D3 D mm (in) ygienic process connections, material: AISI 36L (.4435); Delta ferrite content < % Surface roughness of the surfaces in contact with the medium R a 0.76 µm (30 µin).,3 (0.48),3 (0.48) D3 3 NEUMO BioControl 4 DRD DN50 D K k D K 6 (.4) k h h D3 D D3 D 5 APV Inline D K ø59,5 (.34) k h D3 D Pos. Version Nominal pressure PN Outer D Outer D Internal D3 ole circle K ole circle eight eight h Weight k [kg/lbs] V (.6) 60 (.36) 38 (.5) 5 (.05) (.0) V (3.3) 75 (.95) 4 (.65) 5 (.05) 0.46 (0.94) 3 S4J (3.54) 49.9 (.96) 38 (.5) 5 (.05) 90 (3.54) 3 max. 0 (8.66) 7 (0.67).34 (.95) 4 DR 5 05 (4.3) 65 (.56) 4 (.65) 5 (.05) 84 (3.3) 4 6 (0.63) 0.69 (.36) 5 SP (3.94) 69 (.7) 4 (.65) 5 (.05) 8 (3.3) 5.5 (0.49) 0.59 (.4) mm (in) 4 x M5 thread 4 x M5 thread 3 4 x 9 (0.35); 4 screws DIN9 M8 x 45 are enclosed (material (A4-80)) 4 4 x.5 (0.45) 5 6 x 8.6 (0.34) + x M8 thread; 8 x 45 (= 360 ) 39

40 Mechanical Construction Process connections PPC-M5 (with ceramic process isolating diaphragm) continued Universal adapter b a 3 mm (in) ø43.5 (.7) Material: b = top section AISI 36L (.4404), a = bottom section AISI 36L (.4435); Pepperl+Fuchs supplies the slotted nut in stainless steel AISI 304 (DIN/EN material number.430) or in AISI 304L (DIN/EN material number.4307). Surface roughness of the surfaces in contact with the medium R a 0.76 µm (30 µin). Version Process connection approval Material of the molded seal (changeable) Material of the measuring cell seal (not changeable) at the ceramic sensor 3 Measuring cell seal approval Nominal pressure PN Weight [kg/lbs] U4S EEDG, 3A Silicone EPDM (order version "K") FDA 3A Class II, USP Class VI. DVGW, KTW, W70, WRAS, ACS, NSF (.63) U4E EEDG EPDM EPDM (order version "J") FDA EEDG or 3A approval only with approved process connection. Suitable for foods FDA CFR Installation height, devices with universal adapter F3 housing (I, J) F5 housing (Q, R, S) eight 96 mm (7.7 in) 89 mm (7.44 in) 40

41 Mechanical Construction Process connections LC-M5 (with metallic process isolating diaphragm) Thread, internal process isolating diaphragm G/A G/A G/ 4 G /A.4 M0x.5 Process connections LC-M5, thread ISO and DIN Installation height 4. Thread ISO 8 G/A EN 837; Material version G: AISI 36L, version GC: Alloy C76; weight: 0.6 kg (.3 lbs) Thread ISO 8 G/A G/4 (female); Material version G4: AISI 36L, version G3: Alloy C76; weight: 0.6 kg (.3 lbs) 3 Thread ISO 8 G/A hole.4 mm (0.45 in); Material version GM: AISI 36L, version GN: Alloy C76; weight: 0.6 kg (.3 lbs) 4 Thread DIN3 M0x,5 Material version G74: AISI 36L; weight 0.4 kg (0.88 lbs) Process connections LC-M5, thread ANSI Installation height 4. Thread ANSI /MNPT /4FNPT; Material versions RLJ: AISI 36L, versions RLC: Alloy C76; weight: 0.6 kg (.3 lbs) Thread ANSI /MNPT hole: 400 bar (6000 psi) =.4 mm (0.45 in) Material version RKJ: AISI 36L, version RKC: Alloy C76; weight: 0.6 kg (.3 lbs) 3 Thread ANSI /FNPT; Material version RJ: AISI 36L, version RC: Alloy C76; weight: 0.7 kg (.54 lbs) Installation height for devices with threaded connection and internal process isolating diaphragm ø.4 ø ø3. ø3 G/4 ø7.5 ø6 ø6 ø7.5 G/ A ø7.5 ø7.5 G/A G/A G/A 3 3 /MNPT /4FNPT /MNPT /FNPT 3 ø.4 ø.4 ø /4NPT ø.4 /NPT /NPT /NPT ø38 F3 housing (I, J) F5 housing (Q, R, S) eight 69 mm (6.65 in) 50 mm (5.9 in) 4

42 Mechanical Construction Process connections LC-M5 (with metallic process isolating diaphragm) continued Thread, flush-mounted process isolating diaphragm G/A GA Thread ISO 8 Installation height 43. Thread ISO 8 G/A DIN 385 (Viton seal included); Material version GO: AISI 36L, version GP: Alloy C76; weight: 0.4 kg (0.88 lbs) Thread ISO 8 GA (Viton seal included); material version G3: AISI 36L; weight: 0.7 kg (.54 lbs) 3 Thread ISO 8 G-/A; material version G5: AISI 36L; weight:. kg (.43 lbs) 4 Thread ISO 8 GA; material version G6: AISI 36L; weight:.5 kg (3.3 lbs) Pepperl+Fuchs offers a pressure sensor dummy for the welding neck. Version G73: thread ISO 8 G/; weight: 0.4 kg (0.88 lbs) ø ø d M = ø7.5 G/A ø3.6 ø6.5 ø30 GA ø36 ø39 d M = ø8 3 G-/A GA 4 5 M0x.5 8 ø d M = ø8 d M = ø8 ø36 ø56.3 G-/A GA ø55 ø68 d M = ø7.5 M0x.5 ø3.6 ø6.5 Welded neck AF7 Viton seal G/ ø6 G ½ ø50 3 O-Ring 4 x.78 Viton or NBR Max. pressure resistance 00 bar 4

43 Mechanical Construction 3/4MNPT MNPT -/MNPT MNPT Process connections LC-M5, thread ANSI Installation height see table below. Thread ANSI 3/4MNPT; Material version N: AISI 36L; weight: 0.6 kg (.3 lbs) Thread ANSI MNPT; Material version N3: AISI 36L; weight: 0.7 kg (.54 lbs) 3 Thread ANSI -/MNPT; Material version N5: AISI 36L; weight:.0 kg (. lbs) 4 Thread ANSI MNPT Material version N6: AISI 36L; weight:.3 kg (.86 lbs) Installation height for devices with threaded connection and flush-mounted process isolating diaphragm Description F3 housing (I, J) F5 housing (Q, R, S) G/ 63 mm (6.4 in) 48 mm (5.83 in) G 67 mm (6.57 in) 5 mm (5.98 in) G-/A 63 mm (6.4 in) 48 mm (5.83 in) GA 6 mm (6.38 in) 47 mm (5.79 in) 3/4MNPT 65 mm (6.5 in) 50 mm (5.9 in) MNPT 6 mm (6.38 in) 47 mm (5.79 in) -/MNPT 69 mm (6.65 in) 50 mm (5.9 in) MNPT 99 mm (7.83 in) 44 mm (5.67 in) M0x.5 63 mm (6.4 in) 48 mm (5.83 in) d M = ø8 d M = ø8 d M = ø8 d M = ø8 3/4NPT NPT -/NPT NPT 43

44 Mechanical Construction Process connections LC-M5 (with metallic process isolating diaphragm) continued EN/DIN flanges, connection dimensions as per EN 09-/DIN 57 g h d M = ø8 60 (m) g k D Process connections LC-M5, EN/DIN flange with raised face, material AISI 36L : device height = height of device without flange h and flange thickness b eight 45. b Flange Boltholes Version Nominal diameter Nominal pressure Shape Diameter Thickness Raised face Width of the raised face Quantity Diameter ole circle Flange weight 3 D b g (m) g k [mm] [mm] [mm] [mm] [mm] [mm] [kg] CNJ DN5 PN0-40 B (D) CPJ DN3 PN0-40 B (D) CQJ DN40 PN0-40 B (D) CXJ DN50 PN5/40 B (D) CZJ DN80 PN0-40 B (D) The roughness of the surface in contact with the medium is R a 0.8 µm (3.5 µin). Lower surface roughness available on request. Designation as per DIN 57 in brackets 3 ousing weight 49 4 With these process connections the sealing surface is smaller than described in the standard. Due to a smaller sealing surface a special seal must be used. Contact a seal manufacturer or your local Pepperl+Fuchs Sales Center. 44

45 Mechanical Construction Process connections LC-M5 (with metallic process isolating diaphragm) continued ANSI flanges, connection dimensions as per ANSI B 6.5, raised face RF g d M = ø8 60 (m) g k D Process connection LC-M5, ANSI flange with raised face RF (see table below) : device height = height of device without flange h and flange thickness b. For height 45. Process connections LC-M5 (with metallic process isolating diaphragm) continued eight for devices with flange b h Flange Boltholes Material Nominal diameter Class/ nominal pressure Diameter Version Thickness Diameter of raised face Width of raised face Qua ntity Diameter ole circle Flange weight D b g (m) g k [in] [in]/[mm] [in]/[mm] [in]/[mm] [in]/[mm] [in]/[mm] [in]/[mm] [kg] ANSI flanges A9 AISI 36/36L lb./sq.in 4.88/4 0.69/ / / /9. 3.5/ A5 AISI 36/36L 3 -/ 50 lb./sq.in 5/7 0.69/ / / / / A5 AISI 36/36L 3 -/ 300 lb./sq.in 6./ / / / /.4 4.5/4.3.6 A6 AISI 36/36L 3 50 lb./sq.in 6/ /9. 3.6/ / /0.7.4 A6 AISI 36/36L lb./sq.in 7.5/ /.3 3.6/ /9. 5/7 3. A8 AISI 36/36L lb./sq.in 7.5/ /3.9 5/ /9. 6/ A8 AISI 36/36L lb./sq.in 8.5/09.5./8.6 5/ /.4 6.6/ A9 AISI 36/36L lb./sq.in 9/ / / /9. 7.5/ A9 AISI 36/36L lb./sq.in 0/54.5/ / / /00..6 The roughness of the surface in contact with the medium is R a 0.8 µm (3.5 µin). Lower surface roughness available on request. ousing weight 49 3 Combination of AISI 36 for required pressure resistance and AISI 36L for required chemical resistance (dual rated) 4 With these process connections the sealing surface is smaller than described in the standard. Due to a smaller sealing surface a special seal must be used. Contact a seal manufacturer or your local Pepperl+Fuchs Sales Center. F3 housing (I, J) F5 housing (Q, R, S) eight 65 mm (6.5 in) 50 mm (5.9 in) 45

46 Mechanical Construction Process connections LC-M5 (with metallic process isolating diaphragm) continued ygienic process connection, flush-mounted process isolating diaphragm d M d D ygienic process connections, material: AISI 36L (.4435) Surface roughness of the surfaces in contact with the medium R a 0.76 µm (30 µin). d M d D 3 4 m d M D D3 d M D D3 m m m 5 6 d M D D3 d M D D3 Pos. Version Nominal pressure PN Outer D Outer D3 Seal d Membrane eight eight m Weight d M kg (lbs) Clamp DN8- TBJ (.34) 7.5 (.08) 7. (0.68) 0.5 (.0) Clamp in T (.99) 43.5 (.7).65 (0.85) 0.6 (.3) Clamp -/ in T (.99) 43.5 (.7) 8 (.0) 0.6 (.3) Clamp in T (.5) 56.5 (.) 8 (.0) 0.7 (.54) 3 4 DIN85 B5 M (.7) 63 (.48) 8 (.0) (0.83) 0.7 (.54) DIN85 B3 M (.94) 70 (.76) 8 (.0) max. 65 (6.5) (0.83) 0.8 (.76) DIN85 B40 M (.8) 78 (3.07) 8 (.0) (0.83) 0.9 (.98) DIN85 B50 M (.65) 9 (3.6) 8 (.0) (0.87). (.43) 5 SMS in S (.4) 5 (.0).65 (0.85) 0 (0.79) 0.7 (.54) 6 SMS -/ in S (.7) 74 (.9) 8 (.0) 5 (0.98) 0.8 (.76) SMS in S (.56) 84 (3.3) 8 (.0) 6 (.0) 0.9 (.98) 46

47 Mechanical Construction d M d D D ygienic process connections, material: AISI 36L (.4435) Surface roughness of the surfaces in contact with the medium R a 0.76 µm (30 µin). 8 dm D k D 5.5 (0.6) d M D D (0.08).3 (0.09) R (0.08) d M D D d M D D k 05 (4.3) d M D D.5 (0.5) ø5.5 (0.6) ø8 (0.7) 4 8. (0.74) (0.83) 9.5 (.6) 9 5 mm (in) d M D k D d M D k D ø5.4 () d M D D 9 (0.35) 5 (0.) 7 (.) Pos. Version Nominal pressure PN Outer D Outer D ole circle k Membrane d M eight Weight kg (lbs) 7 Varivent B TPJ (.07) 3 (.) -.65 (0.85) 0.7 (.54) 8 Varivent F TQJ (.6) 53 (.09) - 8 (.0) 0.9 (.98) Varivent N TRJ (3.3) 68 (.68) - 8 (.0). (.43) 9 Neumo D5 SJ 6 64 (.5) 30.4 (.) 50 (.97); 4 x, R 3.5 mm (0.4 in).65 (0.85) 0.8 (.76) 0 Neumo D50 S4J (3.5) 49.9 (.96) 70 (.76); 4 x Ø9 mm (0.35 in) 8 (.0). (.65) DRD TIJ (.54) 5.5 (.07) 84 (3.3); 4 x Ø.5 mm 8 (.0) max. 65 (6.5).0 (.) (0.45 in) APV Inline TMJ (3.9) 69 (.7) 8 (3.3); 6 x Ø8.6 mm (0.34 in) and x M8 8 (.0). (.65) 3 G/ G0J 40 6 G/ (0.69) 0.5 (.) 4 G GZJ 40 G (0.69) 0.8 (.76) 5 G GXJ 00 G (0.69) 0.8 (.76) 47

48 Mechanical Construction Process connections LC-M5 (with metallic process isolating diaphragm) continued Prepared for diaphragm seal mount 5 h ø.5 ø7.95 Version XSJ: prepared for diaphragm seal mount ole for fill fluid Bearing 3 Setscrew with hexagonal recess 4 mm (0.6 in) F3 housing (I, J) F5 housing (Q, R, S) eight 90 mm (7.48 in) 75 mm (6.89 in) 3 48

49 Mechanical Construction Wall and pipe mounting with mounting bracket 69 L PE cable m (6,6 ft), 5 m (6 ft) or 0 m (33 ft). FEP cable 5m (6 ft) F3 housing dimensions. ousing weight 49. Cover without viewing window Cover with viewing window F5 housing dimensions. ousing weight Cover without viewing window 4 Cover with viewing window Weight ousing Process connections Process connections PPC-M5 (with ceramic process isolating diaphragm): 3 ff Process connections LC-M5 (with metallic process isolating diaphragm): 4 ff ø ø5 F3 (I, J), aluminum) F5 (Q, R, S), stainless steel) Separate housing With electronic insert and local display With electronic insert without local display. kg (.43 lbs) 0.8 kg (.76 lbs) Weight of housing kg (.0 lbs)..0 kg (. lbs) 0.7 kg (.54 lbs) Weight of sensor kg (.0 lbs). 49

50 Mechanical Construction Material (not wetted) ousing Front view, left-hand side view, top view Item Component part Material number F3 housing (I, J) Die-cast aluminum with protective powder-coating on polyester base Cover Die-cast aluminum with protective powder-coating on polyester base 3 Cover seal EPDM 4 Sight glass Mineral glass 5 Sight glass seal Silicone (VMQ) 6 External ground terminal AISI 304 (.430) 7 Nameplates Plastic film 8 Attachment for tie-on label AISI 304 (.430)/ AISI 36 (.440) 9 Pressure compensation filter PA6 GF0 0 Pressure compensation filter, O-ring Silicone (VMQ) Sealing ring EPDM Snap ring PC Plastic 3 Seal of cable gland and blind plug EPDM/NBR 4 Cable gland Polyamide (PA) or CuZn nickel-plated 5 Blind plug PBT-GF30 FR for dust ignition-proof, Ex d, FM XP and CSA XP: AISI 36L (.4435) 6 Cover clamp Clamp AISI 36L (.4435), screw A4 50

51 Mechanical Construction Front view, left-hand side view, top view Item Component part Material number F5 housing (Q, R, S) AISI 36L (.4404) Cover 3 Cover seal Silicone with PTFE coating 4 Sight glass for non-hazardous area, Polycarbonate (PC) ATEX Ex ia, NEPSI Zone 0/ Ex ia, IECEx Zone 0/ Ex ia, FM NI, FM IS, CSA IS 4 Sight glass for ATEX / D, ATEX /3 D, Mineral glass ATEX GD, ATEX / GD, ATEX 3 G, FM DIP, CSA dust ignition-proof 5 Sight glass seal Silicone (VMQ) 6 External ground terminal AISI 304 (.430) 7 Attachment for tie-on label AISI 304 (.430)/ AISI 36 (.440) 8 Pressure compensation filter PA6 GF0 9 Pressure compensation filter, O-ring Silicone (VMQ) 0 Nameplates lasered Cable gland Polyamide (PA), for dust ignition-proof: CuZn nickel-plated Seal of cable gland and blind plug NBR/Silicone/EPDM 3 Sealing ring EPDM 4 Screw A4-50 5

52 Mechanical Construction Connecting parts Item Component parts Material number Connection between the AISI 36L (.4404) housing and process connection Mounting bracket Bracket AISI 304 (.430), AISI 304L (.4306) 3 Screw and nuts A-70 4 alf-shells: AISI 304L (.4306) 5 Seal for cable from FKM, EPDM separate housing 6 Gland for cable from separate housing: Screws: AISI 36L (.4404) A or A4 7 PE cable for separate housing Abrasion-proof cable with strain-relief Dynema members; shielded using aluminum-coated film; insulated with polyethylene (PE-LD), black; copper wires, twisted, UV-resistant 8 FEP cable for separate housing 9 Process connection adapter for separate housing Abrasion-proof cable; shielded using galvanized steel wire netting; insulated with fluorinated ethylene propylene (FEP), black; copper wires, twisted, UV-resistant AISI 36L (.4404) Filling oil See "Ordering Information" 65 ff. Miscellaneous: Protective hose for diaphragm seal capillary: AISI 304 (.430) 5

53 Mechanical Construction Material (wetted) The wetted device components are listed in the "Mechanical Construction" section ( 3 ff) and "Ordering Information" section ( 65 ff). TSE Certificate of Suitability (Transmissible Spongiform Encephalopathy) The following applies to all process wetted device components: They do not contain any materials derived from animals. No auxiliaries or operating materials derived from animals are used in production or processing. Process connections "Clamp connections" and "ygienic process connections" (see also "Ordering Information" section): AISI 36L (DIN/EN material number.4435) Pepperl+Fuchs supplies process connections with threaded connections and DIN/EN flanges made of stainless steel as per AISI 36L (DIN/EN material number.4404 (AISI 36) or 4435). With regard to their stability-temperature property, the materials.4404 and.4435 are grouped together under 3E0 in EN 09- Tab.8. The chemical composition of the two materials can be identical. Some process connections are also available in the material Alloy C76 (DIN/EN material number.489). See the information in the "Mechanical Construction" section. Process isolating diaphragm PPC-M5: Al O 3 Aluminium-oxide ceramic, (FDA CFR 86.56, USP Class VI), ultrapure 99.9 % LC-M5: AISI 36L (DIN/EN material number.4435) AISI 36L with gold-rhodium coating Alloy C76 (DIN/EN material number.489) Seals See "Ordering Information", 65 ff 53

54 uman Interface uman Interface Operating elements Local display (optional) for devices with ART or PROFIBUS PA electronics A 4-line liquid crystal display (LCD) is used for display and operation. The local display shows measured values, dialog texts as well as fault and notice messages in plain text, thereby supporting the user at every stage of operation. The liquid crystal display of the device can be turned in 90 stages. Depending on the orientation of the device, this makes it easy to operate the device and read the measured values. Functions: 8-digit measured value display including sign and decimal point, bar graph for 4 ma to 0 ma ART as current display; or for PROFIBUS PA as graphic display of the standardized value of the AI Block. Three keys for operation Simple and complete menu guidance as parameters are split into several levels and groups Each parameter is given a 3-digit ID number for easy navigation Possibility of configuring the display to suit individual requirements and preferences, such as language, alternating display, contrast setting, display of other measured values such as sensor temperature etc. Comprehensive diagnostic functions (fault and warning message etc.) Measured value display Device tag Value eader line Main line Information line Symbol + E Bargraph Unit Operating keys Operating menu Parameter with selection list Selection options Direct Access Code Freely editable parameter Value that can be edited 54

55 uman Interface Local display (optional) for devices with analog electronics A 4-line liquid crystal display (LCD) is used. The local display shows measured values, fault messages and notice messages. The liquid crystal display of the device can be turned in 90 stages. Depending on the orientation of the device, this makes it easy to operate the device and read the measured values. Functions: 8-digit measured value display including sign and decimal point, bar graph for 4 ma to 0 ma as current display. Diagnostic functions (fault and warning message etc.) Measured value display Value Main line Information line Symbol Unit Bargraph Operating keys and elements located on the electronic insert 7 6 Zero Span Display on 5 off ART electronic insert DIP switch for locking/unlocking parameters relevant to the measured value DIP switch for switching damping on/off 3 DIP switch for alarm current SW/Alarm Min (3.6 ma) 4 DIP switch not active 5 Slot for optional local display 6 Green LED to indicate successful operation 7 Operating keys for lower range value (zero), upper range value (span), position zero adjustment or reset damping SW / Alarm min SW / e SW / P=igh delta p only on off damping SW / Alarm min SW / e 3 4 SW / P=igh 55

56 uman Interface Zero Span Display on 3 off on off damping Analog electronic insert Operating keys for lower range value (zero), upper range value (span), position zero adjustment or reset Green LED to indicate successful operation 3 Slot for optional local display 4 DIP switch for switching damping on/off PROFIBUS PA electronic insert DIP switch for locking/unlocking parameters relevant to the measured value DIP switch for switching damping on/off 3 Not used 4 Not used 5 Not used 6 DIP-switch for hardware address 7 DIP-switch for bus address SW/W 8 Slot for optional local display 9 Operating key for position zero adjustment (Zero) or reset 0 Green LED to indicate successful operation damping damp not used 3 delta p on: off:sw 4 only on:p= igh off:sw 5 e Zero Display on off 8 on off Address SW W on off damping not used SW / e SW / P=igh

57 uman Interface Onsite operation Function Operation without display with operating keys and DIP switches on the electronic insert Analog electronics ART PROFIBUS PA Position adjustment (zero point correction) X X X Setting lower range value and upper range value reference pressure present at the device X X Device reset X X X Locking and unlocking parameters relevant to the measured value Value acceptance indicated by the green LED X X X X X Switching damping on and off X X X Function Operation via display (option) Analog electronics ART PROFIBUS PA Position adjustment (zero point correction) X X Setting lower range value and upper range value reference pressure present at the device X X Device reset X X Locking and unlocking parameters relevant to the measured value Value acceptance indicated by the green LED X X Switching damping on and off X X Remote operation All software parameters are accessible depending on the position of the write protection switch on the device. ART Remote operation via: PACTware TM Field communication PROFIBUS PA Remote operation via: Profiboard: For connecting a PC to PROFIBUS Proficard: For connecting a laptop to PROFIBUS 57

58 uman Interface ardware and software for onsite and remote operation Field communication Compact, flexible and robust industry handheld terminal for remote parametrization and measured value inspection via the ART current output (4 ma to 0 ma). PACTware TM PACTware TM based on FDT technology. With PACTware TM, you can configure all Pepperl+Fuchs devices as well as devices from other manufacturers that support the FDT standard. The software supports the following functions: Configuration of transmitters in offline and online mode Loading and saving device data (upload/download) Documentation of the measuring point Connection options: ART via field communication and the USB port on a computer PROFIBUS PA via segment coupler and PROFIBUS interface card For further information see 58

59 Planning Instructions for Diaphragm Seal Systems Planning Instructions for Diaphragm Seal Systems The performance and the permitted applications for a diaphragm seal system depend on the process isolating diaphragm used, the filling oil, the coupling, the design and the process and ambient conditions at the place of operation. For further details, or for information on an optimum diaphragm seal solution, please contact your local Pepperl+Fuchs Sales Center. Applications Function and design Diaphragm seal systems should be used if the process and the device need to be separated. Diaphragm seal systems offer clear advantages in the following instances: In the case of extreme process temperatures For aggressive media If extreme measuring point cleaning is necessary, or in the event of very damp mounting locations If the measuring point is exposed to severe vibrations For mounting locations that are difficult to access Diaphragm seals separate the measuring system from the process. A diaphragm seal system consists of: A diaphragm seal A capillary tube or a temperature isolator if necessary Fill fluid A pressure transmitter The process pressure acts via the process isolating diaphragm of a diaphragm seal on the liquidfilled system, which transfers the process pressure to the sensor of the pressure transmitter. Pepperl+Fuchs delivers all diaphragm seal systems as welded versions. The system is hermetically sealed, which ensures greater reliability. The diaphragm seal determines the application range of the system on the basis of The diameter of the process isolating diaphragm The process isolating diaphragm: stiffness and material The design (oil volume) Diameter of the process isolating diaphragm The greater the diameter of the process isolating diaphragm (less stiff), the smaller the temperature effect on the measurement result. Stiffness of the process isolating diaphragm The stiffness depends on the diameter of the process isolating diaphragm, the material, any existing coating, the thickness of the process isolating diaphragm and the shape. The thickness of the process isolating diaphragm and the shape are determined by the design. The stiffness of a process isolating diaphragm of a diaphragm seal influences the temperature application range and the measuring error caused by temperature effects. Capillary Capillaries with an internal diameter of mm (0.04 in) are used as standard. As a result of its length and internal diameter, the capillary tube influences the thermal change, the ambient temperature application range and the response time of a diaphragm seal system. Filling oil When selecting the filling oil, the medium temperature and ambient temperature, as well as the process pressure, are of crucial importance. Observe the temperatures and pressures during commissioning and cleaning. A further selection criterion is the compatibility of the filling oil with the requirements of the medium. For example, only filling oils that do not present a health hazard are used in the food industry, e. g. vegetable oil or silicone oil. See also the following section "Diaphragm seal filling oils". The filling oil used influences the thermal change, the temperature application range of a diaphragm seal system and the response time. A temperature change results in a volume change in the filling oil. The volume change depends on the thermal expansion coefficient of the filling oil and on the volume of the fill fluid at calibration temperature (constant in the range: + C to +33 C (+70 F to 9 F)). For example, the filling oil expands in the event of a temperature increase. The additional volume presses against the process isolating diaphragm of a diaphragm seal. The stiffer a process isolating diaphragm is, the greater its return force, which counteracts a volume change and acts together with the process pressure on the measuring cell, thus shifting the zero point. 59

60 Planning Instructions for Diaphragm Seal Systems Diaphragm seal filling oils Pressure transmitter The pressure transmitter influences the temperature application range, the thermal change and the response time as a result of its volume change. The volume change is the volume that has to be shifted in order to pass through the complete measuring range. Pressure transmitters from Pepperl+Fuchs are optimized with regard to minimum volume change. Filling oil Permissible temperature range at 0.05 bar (0.75 psi) p abs bar (4.5 psi) Permissible temperature range ) at p abs bar (4.5 psi) Density [g/cm 3 ]/ [SGU] Viscosity [mm²/s]/[cst] at 5 C (77 F)] Thermal expansion coefficient [/K] Note Silicone oil -40 C to +80 C (-40 F to +356 F) Inert oil -40 C to +80 C (-40 F to +76 F) -40 C to +50 C (-40 F to +48 F) -40 C to +75 C (-40 F to +347 F) Suitable for foods FDA CFR For ultrapure gas and oxygen applications Vegetable oil -0 C to +0 C (+4 F to +48 F) -0 C to +00 C (+4 F to +39 F) Suitable for foods FDA CFR ightemperature oil Lowtemperature oil -0 C to +00 C (+4 F to +39 F) -70 C to +80 C (-94 F to +76 F) -0 C to +400 C (+4 F to +75 F) -70 C to +80 C (-94 F to +356 F) igh temperatures Low temperatures Observe temperature limits of the device ( 30) and of the system ( 59). When simultaneously applying the diaphragms seal at high process temperatures and low absolute pressures, Pepperl+Fuchs recommends a vacuum service Operating temperature range Installation instructions The operating temperature range of a diaphragm seal system depends on the fill fluid, capillary length and internal diameter, process temperature and oil volume of the diaphragm seal. The range of application can be extended by using a fill fluid with a smaller expansion coefficient and a shorter capillary. Diaphragm seal systems Pepperl+Fuchs offer flushing rings as accessory to clean process isolating diaphragms without taking the transmitters out of process. For further information please contact your local Pepperl+Fuchs Sales Center. A diaphragm seal together with the transmitter form a closed, calibrated system, which is filled through openings in the diaphragm seal and in the transmitter's measurement system. These openings are sealed and must not be opened. In the case of devices with diaphragm seals and capillaries, the zero point shift caused by the hydrostatic pressure of the filling liquid column in the capillaries must be taken into account when selecting the measuring cell. If a measuring cell with a small measuring range is selected, a position adjustment can cause range violation. For devices with a temperature isolator or capillary, a suitable fastening device (mounting bracket) is recommended. When using diaphragm seal systems with a capillary, sufficient strain relief must be ensured in order to prevent the capillary bending down (bending radius 00 mm (3.94 in)). Capillary In order to obtain more precise measurement results and to avoid a defect in the device, mount the capillaries as follows: Vibration-free (in order to avoid additional pressure fluctuations) Not in the vicinity of heating or cooling lines Insulate if the ambient temperature is below or above the reference temperature With a bending radius of 00 mm (3.94 in). 60

61 Planning Instructions for Diaphragm Seal Systems Vacuum applications For applications under vacuum, Pepperl+Fuchs recommends mounting the pressure transmitter below the diaphragm seal. This prevents vacuum loading of the diaphragm seal caused by the presence of fill fluid in the capillary. When the pressure transmitter is mounted above the diaphragm seal, the maximum height difference in accordance with the illustration below must not be exceeded. The maximum height difference depends on the density of the filling oil and the smallest ever pressure that is permitted to occur at the diaphragm seal (empty container), see illustration below right. When simultaneously applying the diaphragm seal systems at high process temperatures and low absolute pressures, Pepperl+Fuchs recommends a vacuum service. eight difference [m] Silicone oil Low temperature oil Vegetable oil igh temperature oil Inert oil Pressure at diaphragm seal [mbar abs ] Installation above the diaphragm seal Maximum installation height above the diaphragm seal for vacuum applications Thermal insulation The devices may only be insulated up to a certain height. The maximum permitted insulation height is indicated on the devices and applies to an insulation material with a heat conductivity 0,04 W/(m x K) and to the maximum permitted ambient and process temperature. The data were determined under the most critical application "quiescent air". T U 0.04 W m K Maximum permitted insulation height, here indicated on an example T P 6

62 Planning Instructions for Diaphragm Seal Systems Mounting with temperature isolator Pepperl+Fuchs recommends the use of temperature isolators in the event of constant extreme medium temperatures which lead to the maximum permissible electronics temperature of +85 C (+85 F) being exceeded. Depending on the filling oil used, diaphragm seal systems with temperature isolators can be used for maximum temperatures of up to 60 C (+500 F). For the temperature application limits, see 60, "Diaphragm seal filling oils" section. To minimize the influence of rising heat, Pepperl+Fuchs recommends the device be mounted horizontally or with the housing pointing downwards. The additional installation height also brings about a maximum zero point shift of mbar (0.35 psi) due to the hydrostatic column in the temperature isolator. You can correct this zero point shift at the device. max. 5 Pressure transmitter with temperature isolator 6

63 Certificates and Approvals Certificates and Approvals CE mark The device meets the legal requirements of the relevant EC directives. Pepperl+Fuchs confirms that the device has been successfully tested by applying the CE mark. Ex approvals ATEX IECEx FM CSA Also combinations of different approvals All explosion protection data are given in separate documentation which is available upon request. The Ex documentation is supplied as standard with all devices approved for use in explosion hazardous areas. 73 ff, "Safety instructions" section and "Installation/Control Drawings" section. Suitability for hygienic processes The pressure transmitter is suitable for use in hygienic processes. Overview of suitable process connections 3 ff. Many versions meet the requirements of 3A-Sanitary Standard No. 74 and are certified by the EEDG. Suitable fittings and seals must be used for hygienic design in accordance with 3A and EEDG specifications. Gap-free connections can be cleaned without residue using the usual cleaning methods. TYPE EL February Functional safety SIL Marine approval CRN approval Pressure Equipment Directive (PED) Drinking water approval The pressure transmitter with 4 ma to 0 ma output signal has been developed to assessed and certified by TÜV NORD CERT as per IEC 6508 Edition.0 and IEC 65. These devices can be used to monitor the process level and pressure up to SIL. For a detailed description of the safety functions, settings and functional safety data, see the "Safety Integrity Level" manual. GL (German Lloyd) Some device versions have CRN approval. For a CRN-approved device, a CRN-approved process connection ( 3 ff, Process connections) has to be ordered with a CSA approval ( 65 ff, ordering information, feature "Approval"). The devices are fitted with a separate plate bearing the registration number. The devices PPC-M5and LC-M5 correspond to Article 3 (3) of the EC directive 97/3/EC (Pressure Equipment Directive) and have been designed and manufactured according to good engineering practice. The following also applies: LC-M5 with threaded connection and internal process isolating diaphragm PN > 00: suitable for stable gases in group, category I NSF6 approval 63

64 Certificates and Approvals Standards and guidelines DIN EN (IEC 60770): Transmitters for use in industrial process control systems Part : Methods for inspection and routine testing DIN 6086: Electrical pressure measuring instruments, pressure sensors, pressure transmitters, pressure measuring instruments, concepts, specifications on data sheets EN 636 series: EMC product family standard for electrical equipment for measurement, control and laboratory use. North-American practice for installation of process seals Pepperl+Fuchs instruments are designed according to ANSI/ISA.7.0 either as single seal or dual seal devices with annunciation, allowing the user to waive the use and save the cost of installing external secondary process seals in the conduit as required by the process sealing sections of ANSI/ NFPA 70 (NEC) and CSA. (CEC). These instruments comply with the North-American installation practice and provide a very safe and cost-saving installation for pressurized applications with hazardous fluids. Further information can be found in the control drawings of the relevant devices. 64

65 Ordering Information Ordering Information Ordering Designation option with * = in preparation Device LC-M5 Pressure transmitter with metallic welded process isolating diaphragm Sensor range Sensors for gauge pressure RD 400 mbar/40 kpa/6 psi/relative/4 m O/3 ft O/60 in O RA bar/00kpa/5psi/relative/0m O/33 ft O/400 in O RC bar/00kpa/30psi/relative/0m O/67 ft O/800 in O RD 4bar/400kpa/60psi/relative/40m O/33 ft O/600 in O R3A 0bar/Mpa/50psi/relative/00m O/333 ft O/4000 in O R3D 40bar/4Mpa/600psi/relative/400m O/334 ft O/6000 in O R4A 00 bar/0 Mpa/500 psi/relative/000 m O/3330 ft O/40000 in O R4D 400 bar/40 Mpa/6000 psi/relative/4000 m O/3340 ft O/60000 in O Sensors for absolute pressure AD 400 mbar/40 kpa/6 psi/absolute/4 m O/3 ft O/60 in O AA bar/00kpa/5psi/absolute/0m O/33 ft O/400 in O AC bar/00kpa/30psi/absolute/0m O/67 ft O/800 in O AD 4bar/400kpa/60psi/absolute/40m O/33 ft O/600 in O A3A 0bar/Mpa/50psi/absolute/00m O/333 ft O/4000 in O A3D 40bar/4Mpa/600psi/absolute/400m O/334 ft O/6000 in O A4A 00 bar/0 Mpa/500 psi/absolute/000 m O/3330 ft O/40000 in O A4D 400 bar/40 Mpa/6000 psi/absolute/4000 m O/3340 ft O/60000 in O XXX Special version Calibration; unit Sensor range; mbar/bar Sensor range; kpa/mpa 3 Sensor range; mm/m O 4 Sensor range; in O/ft O 5 Sensor range; psi A Sensor range; % J Customized pressure (see additional specification) K Customized level (see additional specification) Y Special version Reference accuracy D Platinum G Standard Y Special version Process connection A3 in 300 lbs RF, 36/36L, flange ANSI B6.5 A3 -/ in 50 lbs RF, 36 /36L, flange ANSI B6.5 A5 -/ in 300 lbs RF, 36/36L, flange ANSI B6.5 A6 in 50 lbs RF, 36/36L, flange ANSI B6.5 A6 in 300 lbs RF, 36/36L, flange ANSI B6.5 A8 3 in 50 lbs RF, 36/36L, flange ANSI B6.5 A8 3 in 300 lbs RF, 36/36L, flange ANSI B6.5 A9 4 in 50 lbs RF, 36/36L, flange ANSI B6.5 A9 4 in 300 lbs RF, 36/36L, flange ANSI B6.5 DR * DRD DN50 65 mm PN5, 36L F45 DN5 PN0-40 B, 36L, flange EN 09- F55 DN3 PN0-40 B, 36L, flange EN 09- F65 DN40 PN0-40 B, 36L, flange EN 09- F75 DN50 PN0-40 B, 36L, flange EN 09- F95 DN80 PN0-40 B, 36L, flange EN 09- G Thread ISO8 G/, 36L G3 Thread ISO8 G/ G/4 female, AlloyC 65

66 Ordering Information G4 Thread ISO8 G/ G/4 female, 36L GC Thread ISO8 G/, AlloyC GM Thread ISO8 G/ hole.4 mm, 36L GN Thread ISO8 G/ hole.4 mm, AlloyC GO Thread ISO8 G/, 36L, flush-mounted GP Thread ISO8 G/, AlloyC, flush-mounted G3 Thread ISO8 G, 36L, flush-mounted G5 Thread ISO8 G-/, 36L, flush-mounted G6 Thread ISO8 G, 36L, flush-mounted G7 * Thread ISO8 G flush-mounted, metal sealing cone, 36L G7 * Thread ISO8 G O-ring seal, 36L G73 * Thread ISO8 G/ O-ring seal, fm = flush-mounted, 36L G74 Thread DIN 3 M0x.5, 36L M55 * DIN 85 DN3 PN5 cap-nut, 36L, EEDG, 3A M56 * DIN 85 DN50 PN5 cap-nut, 36L, EEDG, 3A M57 * DIN 85 DN5 PN5 cap-nut, 36L, EEDG, 3A M58 * DIN 85 DN40 PN5 cap-nut, 36L, EEDG, 3A N * Thread ANSI MNPT3/4, 36L, flush-mounted N3 Thread ANSI MNPT, 36L, flush-mounted N5 Thread ANSI MNPT-/, 36L, flush-mounted N6 Thread ANSI MNPT, 36L, flush-mounted RC Thread ANSI FNPT/, AlloyC RJ Thread ANSI FNPT/, 36L RKC Thread ANSI MNPT/ hole.4 mm, AlloyC RKJ Thread ANSI MNPT/ hole.4 mm, 36L RLC Thread ANSI MNPT/ FNPT/4, AlloyC RLJ Thread ANSI MNPT/ FNPT/4, 36L SJ * NEUMO BioControl D5 PN6, 36L, EEDG, 3A S4J * NEUMO BioControl D50 PN6, 36L, EEDG, 3A S45 * SMS " PN5, 36L, EEDG, 3A S55 * SMS -/" PN5, 36L, EEDG, 3A S65 * SMS " PN5, 36L, EEDG, 3A SP6 * APV-Inline DN50 PN40, 36L, 3A T5 * Tri-Clamp ISO85 DN38 (-/ in), 36L, DIN 3676 DN40, EEDG, 3A, ASME-BPE T55 * Tri-Clamp ISO85 DN5 ( in), 36L, DIN 3676 DN5, EEDG, 3A, ASME-BPE T65 * Tri-Clamp ISO85 DN40-5 ( in), 36L, DIN 3676 DN50, EEDG, 3A, ASME-BPE TBJ * Clamp ISO85 DN- (/ in to 3/4 in), 36L, DIN 3676 DN0-0, EEDG, 3A, ASME-BPE TUJ * KingGage 777-(short), 36L, 3A TVJ * KingGage 777(medium), 36L, 3A TWJ * KingGage 777-3(long), 36L, 3A V0 * Varivent B pipe DN0-5 PN40, 36L, EEDG, 3A V * Varivent F pipe DN5-3 PN40, 36L, EEDG, 3A V4 * Varivent N pipe DN40-6 PN40, 36L, EEDG, 3A XSJ Prepared for diaphragm seal mount, 36L XXX Special version Material of the process isolating diaphragm 36 L 4 Allox C A Rhodium>gold>36L X Special version Fill fluid Silicone oil Inert oil 3 Synthetic oil, FDA 9 Special version ousing I Aluminum housing F3 J Aluminum housing F3; glass window Q Stainless steel housing F5, hygienic version 66

67 Ordering Information R Stainless steel housing F5, hygienic version; glass window S Stainless steel housing F5, hygienic version; plastic window Y Special version Output I 4 ma to 0 ma analog electronics I 4 ma to -0 ma SMART electronics, ART protocoll PA PROFIBUS-PA P3.0 9 Special version Electrical connection A Gland M0, IP66/68 NEMA4X/6P B Thread M0, IP66/68 NEMA4X/6P C Thread G/, IP66/68 NEMA4X/6P D Thread NPT/, IP66/68 NEMA4X/6P I Connector M, IP66/68 NEMA4X/6P M Connector 7/8 in, IP66/68 NEMA4X/6P P Connector an7d, 90deg., IP65 S PE cable 5 m, IP66/68 NEMA4X/6P and pressure compensation via cable V Valve connector ISO4400 M6, IP64 Y Special version Display, operation LCD, push buttons on display electronics W/o LCD, push buttons on electronics 9 Special version Approval C CSA C/US IS/XP Cl. I,II Div. Gr. A-G/B-G, Zone, CD CSA C/US Cl. II,III Div. Gr. E-G, US: Zone, CG CSA General Purpose CU CSA C/US IS Cl. I,II,III Div. Gr. A-G, CSA C/US IS Cl. I Div. Gr. A-D, Ex ia, C: Zone 0,,/US: Zone 0,,,0,, CX CSA C/US XP Cl. I,II Div. Gr. B-G, Ex d, (conduit seal not required), Zone, E ATEX II G Ex ia IIC T6 E ATEX II 3G Ex na IIC T6 E3 ATEX II 3G Ex ic IIC T6 ES ATEX II /D Ex t IIIC EX ATEX II /G Ex ia IIC T6 FD FM DIP Cl.II,III Div. Gr. E-G, Zone, FM FM IS Cl. I,II,III Div. Gr. A-G, AEx ia, FM NI Cl. I Div. Gr. A-D, FM IS: Zone 0,,,0,,/FM NI: Zone FN FM NI Cl. I Div. Gr. A-D, Zone I IEC Ex ia IIC T6 Ga/Gb + Ex ia IIIC Da/Db IA IEC Ex ia IIC T6 Ga/Gb IB IEC Ex d IIC T6 Gb ID IEC Ex t IIIC Da/Db IE IEC Ex ic IIC T6 Gc NA For non-hazardous areas SX ATEX II /G Ex ia IIC T6 + ATEX II /D Ex iad Options option with * = in preparation no option = 0 Additional operation language A English B German C French D Spanish E Italian K Chinese simplified 67

68 Ordering Information L Japanese Calibration Factory calibration certificate, 5-point Service (multiple selection possible) F Oil and grease removed (only device, not accessory or enclosed accessory) Test, certificate (multiple selection possible) 3 Material certification, metallic parts in contact with medium, EN inspection certificate Other approvals (multiple selection possible) SIL J GL marine certificate Separate housing (multiple selection possible) 6 Cable PE, m/80 in and housing mounting bracket, wall/pipe, Cable PE, 5 m/00 in and housing mounting bracket, wall/pipe, Cable PE, 0 m/400 in and housing mounting bracket, wall/pipe, Cable FEP, 5 m/00 in IP69K and housing mounting bracket, wall/pipe, 304 Firmware version M 0.00.zz, PROFIBUS PA, DevRev0 N 0.00.zz, ART, DevRev0 Identification (multiple selection possible) O Measuring point (TAG), see additional specification P Bus address, see additional specification Q * Mounting accessory, see additional specification 68

69 Ordering Information Ordering Designation option with * = in preparation Device PPC-M5 Pressure transmitter with ceramic process isolating diaphragm Sensor range Sensors for gauge pressure RA 00 mbar/0 kpa/,5 psi/relative/4 m O/3 ft O/40 in O RC 50 mbar/5 kpa/3,75 psi/relative/,5 m O/7.5 ft O/00 in O RD 400 mbar/40 kpa/6 psi/relative/4 m O/3 ft O/60 in O RA bar/00kpa/5psi/relative/0m O/33 ft O/400 in O RC bar/00kpa/30psi/relative/0m O/67 ft O/800 in O RD 4bar/400kpa/60psi/relative/40m O/33 ft O/600 in O R3A 0bar/Mpa/50psi/relative/00m O/333 ft O/4000 in O R3D 40bar/4Mpa/600psi/relative/400m O/334 ft O/6000 in O Sensors for absolute pressure AA 00 mbar/0 kpa/,5 psi/absolute/ m O/3 ft O/40 in O AC 50 mbar/5 kpa/3,75 psi/absolute/,5 m O/7.5 ft O/00 in O AD 400 mbar/40 kpa/6 psi/absolute/4 m O/3 ft O/60 in O AA bar/00kpa/5psi/absolute/0m O/33 ft O/400 in O AC bar/00kpa/30psi/absolute/0m O/67 ft O/800 in O AD 4bar/400kpa/60psi/absolute/40m O/33 ft O/600 in O A3A 0bar/Mpa/50psi/absolute/00m O/333 ft O/4000 in O A3D 40bar/4Mpa/600psi/absolute/400m O/334 ft O/6000 in O XXX Special version Calibration; unit Sensor range; mbar/bar Sensor range; kpa/mpa 3 Sensor range; mm/m O 4 Sensor range; in O/ft O 5 Sensor range; psi A Sensor range; % J Customized pressure (see additional specification) K Customized level (see additional specification) Y Special version Reference accuracy D Platinum G Standard Y Special version Process connection A3 in 50 lbs RF, 36/36L, flange ANSI B6.5 A3 in 300 lbs RF, 36/36L, flange ANSI B6.5 A5 -/ in 50 lbs RF, 36/36L, flange ANSI B6.5 A5 -/ in 300 lbs RF, 36/36L, flange ANSI B6.5 A6V in 50 lbs RF, PVDF, flange ANSI B6.5 A6 in 50 lbs RF, 36/36L, flange ANSI B6.5 A6 in 300 lbs RF, 36/36L, flange ANSI B6.5 A6 in 50 lbs, ECTFE>36/36L, flange ANSI B6.5 A8 3 in 50 lbs RF, 36/36L, flange ANSI B6.5 A8 3 in 300 lbs RF, 36/36L, flange ANSI B6.5 A8 3 in 50 lbs, ECTFE>36/36L, flange ANSI B6.5 A8V 3 in 50 lbs RF, PVDF, flange ANSI B6.5 A9 4 in 50 lbs RF, 36/36L, flange ANSI B6.5 A9 4 in 300 lbs RF, 36/36L, flange ANSI B6.5 A9 4 in 50 lbs, ECTFE>36/36L, flange ANSI B6.5 DR * DRD DN50 65 mm PN5, 36L 69

70 Ordering Information F45 DN5 PN0-40 B, 36L, flange EN 09- F55 DN3 PN0-40 B, 36L, flange EN 09- F6 * DN40 PN0/6 B, PVDF, flange EN 09- F65 DN40 PN0-40 B, 36L, flange EN 09- F6 DN40 PN0-40, ECTFE>36L, flange EN 09- F7 DN50 PN0/6 B, PVDF, flange EN 09- F75 DN50 PN0-40 B, 36L, flange EN 09- F7 DN50 PN5/40, ECTFE>36L, flange EN 09- F95 DN80 PN0-40 B, 36L, flange EN 09- F9 DN80 PN5/40, ECTFE>36L, flange EN 09- G Thread ISO8 G/, 36L G3 Thread ISO8 G/ G/4 female, AlloyC G4 Thread ISO8 G/ G/4 female, 36L GC Thread ISO8 G/, AlloyC GM Thread ISO8 G/ hole.4 mm, 36L GN Thread ISO8 G/ hole.4 mm, AlloyC GV Thread ISO8 G/, PVDF G44 Thread DIN 3 M44x.5, 36L, flush-mounted G5 Thread ISO8 G-/, 36L, flush-mounted G6 Thread ISO8 G, 36L, flush-mounted J6 0K 50A RF, 36L, flange JIS B0 J7 0K 80A RF, 36L, flange JIS B0 J9 0K 00A RF, 36L, flange JIS B0 J3 Thread JIS B00 G/ male, 36L J3 Thread JIS B003 R/ male, 36L M56 * DIN 85 DN50 PN5 cap-nut, 36L, EEDG, 3A M58 * DIN 85 DN40 PN5 cap-nut, 36L, EEDG, 3A M64 DIN 864- A DN40 PN6 pipe DIN 866-A, cap-nut, 3with seal6l, EEDG, 3A with seal FDA M65 DIN 864- A DN50 PN6 pipe DIN 866-A, cap-nut, 36L, EEDG, 3A with seal FDA N5 Thread ANSI MNPT-/, 36L, flush-mounted N6 Thread ANSI MNPT, 36L, flush-mounted RC Thread ANSI FNPT/, AlloyC RJ Thread ANSI FNPT/, 36L RJF Thread ANSI MNPT/ hole 3 mm, PVDF RKC Thread ANSI MNPT/ hole.4 mm, AlloyC RKJ Thread ANSI MNPT/ hole.4 mm, 36L RLC Thread ANSI MNPT/ FNPT/4, AlloyC RLJ Thread ANSI MNPT/ FNPT/4, 36L S4J * NEUMO BioControl D50 PN6, 36L, EEDG, 3A SP6 * APV-Inline DN50 PN40, 36L, 3A T65 * Tri-Clamp ISO85 DN40-5 ("), 36L, DIN 3676 DN50, EEDG, 3A, ASME-BPE T85 Tri-Clamp ISO85 DN76. (3"), 36L, EEDG, 3A with seal FDA U4E Universaladapter 44 mm 36L, EPDM molded seal, EEDG U4S Universaladapter 44 mm 36L, silicone molded seal, EEDG, 3A with seal FDA V *Varivent F pipe DN5-3 PN40, 36L, EEDG, 3A V4 *Varivent N pipe DN40-6 PN40, 36L, EEDG, 3A XXX Special version for welded nozzles (only with vegetable oil) Seal material FKM Viton 4 EPDM, FDA B FKM Viton, FDA, 3A Class I, USP Class VI F NBR G NBR, FDA, 3A Class II, KTW, AFNOR, BAM NBR, low temperature K EPDM, FDA, 3A Class II, USP Class VI, DVGW, KTW, W70, WRAS, ACS, NSF6 L FFKM Kalrez 6375 M FFKM Kalrez 7075 N FFKM Kalrez 6, FDA, USP Class VI P Fluoroprene XP40, FDA, USP Class VI, 3A Class I 70

71 Ordering Information S VMQ Silicone, FDA X Special version ousing I Aluminum housing F3 J Aluminum housing F3; glass window Q Stainless steel housing F5, hygienic version R Stainless steel housing F5, hygienic version; glass window S Stainless steel housing F5, hygienic version; plastic window Y Special version Output I 4 ma to 0 ma analog electronics I 4 ma to -0 ma SMART electronics, ART protocoll PA PROFIBUS-PA, P3.0 9 Special version Electrical connection A Gland M0, IP66/68 NEMA4X/6P B Thread M0, IP66/68 NEMA4X/6P C Thread G/, IP66/68 NEMA4X/6P D Thread NPT/, IP66/68 NEMA4X/6P I Connector M, IP66/68 NEMA4X/6P M Connector 7/8 in, IP66/68 NEMA4X/6P P Connector an7d, 90deg., IP65 S PE cable 5 m, IP66/68 NEMA4X/6P and pressure compensation via cable V Valve connector ISO4400 M6, IP64 Y Special version Display, operation LCD, push buttons on display electronics W/o LCD, push buttons on electronics 9 Special version Approval CU CSA C/US IS Cl. I,II,III Div. Gr. A-G, CSA C/US IS Cl. I Div. Gr. A-D, Ex ia, C: Zone 0,,/US: Zone 0,,,0,, CG CSA General Purpose E ATEX II G Ex ia IIC T6 E ATEX II 3G Ex na IIC T6 E3 ATEX II 3G Ex ic IIC T6 EM ATEX II /D Ex ia IIIC ES ATEX II /D Ex t IIIC EX ATEX II /G Ex ia IIC T6 FM FM IS Cl. I,II,III Div. Gr. A-G, AEx ia, FM NI Cl. I Div. Gr. A-D, FM IS: Zone 0,,,0,,/FM NI: Zone FN FM NI Cl. I Div. Gr. A-D, Zone IA IEC Ex ia IIC T6 Ga/Gb IE IEC Ex ic IIC T6 Gc IF IEC Ex ia IIIC Da/ Db I IEC Ex ia IIC T6 Ga/Gb+Ex ia IIIC Da/Db NA For non-hazardous areas SX ATEX II /G Ex ia IIC T6 +ATEX II /D Ex iad Options option with * = in preparation no option = 0 Additional operation language A English B German C French 7

72 Ordering Information D Spanish E Italian K Chinese simplified L Japanese Calibration Factory calibration certificate, 5-point Service (multiple selection possible) F Oil and grease removed Test, certificate (multiple selection possible) 3 Material certification, metallic parts in contact with medium, EN inspection certificate Other approvals (multiple selection possible) SIL J GL marine certificate Separate housing (multiple selection possible) 6 Cable PE, m/80 in and housing mounting bracket, wall/pipe, Cable PE, 5 m/00 in and housing mounting bracket, wall/pipe, Cable PE, 0 m/400 in and housing mounting bracket, wall/pipe, Cable FEP, 5 m/00 in IP69K and housing mounting bracket, wall/pipe, 304 Firmware version M 0.00.zz, PROFIBUS PA, DevRev0 N 0.00.zz, ART, DevRev0 Identification (multiple selection possible) O Measuring point (TAG), see additional specification P Bus address, see additional specification Q * Mounting accessory, see additional specification 7

73 Supplementary Documentation Supplementary Documentation Technical Information LCR-5, LCS-5: TI00437O/98/EN Operating Instructions 4 ma to 0 ma Analog: BA00385O/98/EN 4 ma to 0 ma ART: BA0038O/98/EN PROFIBUS PA: BA00383O/98/DE Brief Operating Instructions Functional safety manual (SIL) 4 ma to 0 ma Analog: KA0036O/98/EN 4 ma to 0 ma ART: KA0030O/98/EN PROFIBUS PA: KA003O/98/EN 4 ma... 0 ma ART: SD00347O/98/EN Safety instructions Authorities Version in the order code Approval Category Type ousing Electronics Documentation F3 F5 EX Ex ia IIC II / G PPC-M5, LC-M5 X X 4 ma to 0 ma ART SI00464O/98 ES Ex t IIIC II / D PPC-M5, LC-M5 X X 4 ma to 0 ma ART SI00466O/98 E Ex na II 3 G PPC-M5, LC-M5 X X 4 ma to 0 ma ART PROFIBUS PA SI00469O/98 ATEX E Ex ia IIC II G PPC-M5, LC-M5 X X 4 ma to 0 ma ART SI00464O/98 EM Ex ia IIIC II / D PPC-M5 X X 4 ma to 0 ma ART SI00465O/98 E3 Ex ic IIC II 3 G PPC-M5, LC-M5 X X 4 ma to 0 ma ART SI00489O/98 SX Ex ia IIC Ex ia IIIC II / G II / D PPC-M5, LC-M5 X X 4 ma to 0 ma ART SI00468O/98 Authorities Version in the order code Approval EPL Type ousing Electronics Documentation F3 F5 IA Ex ia IIC Ga/Gb PPC-M5, LC-M5 X X 4 ma to 0 ma ART SI00470O/98 ID Ex t IIIC Da/Db LC-M5 X X 4 ma to 0 ma ART SI0047O/98 IECEx IE Ex ic IIC Gc PPC-M5, LC-M5 X X 4 ma to 0 ma ART SI00488O/98 IF Ex ia IIIC Da/Db PPC-M5 X X 4 ma to 0 ma ART SI00487O/98 I Ex ia IIC Ex ia IIIC Ga/Gb Da/Db PPC-M5, LC-M5 X X 4 ma to 0 ma ART SI00473O/98 73

74 Supplementary Documentation Installation/Control Drawings Authorities Version in the order code Approval Type ousing Electronics Documentation F3 F5 FD FM NI Cl. I Div. Gr. A-D, Zone LC-M5 X X 4 ma... 0 ma ART In preparation FM FM FM IS Cl. I, II, III Div. Gr. A-G, AEx ia, FM NI Cl.I Div. Gr. A-D, FM IS: Zone 0,,, 0,, / FM NI: Zone PPC-M5, LC-M5 X X 4 ma... 0 ma ART PROFIBUS PA SI00563O/98 SI00564O/98 FN FM NI Cl. I Div. Gr. A-D, Zone PPC-M5, LC-M5 X 4 ma... 0 ma ART SI00567O/98 CU C/US IS Cl.I,II,III Div. Gr.A-G, C/US IS Cl.I Div. Gr.A-D, Ex ia PPC-M5, LC-M5 X X 4mAto 0 ma ART PROFIBUS PA SI00556O/98 SI00558O/98 CSA CX CD CSA C/US CP Cl.I, II Div. Gr.B-G, Ex d (factory sealed) Zone, CSA C/US Cl.II, III Div. Gr.E-G, Zone, LC-M5 X 4 ma to 0 ma ART ZD0049O/98 LC-M5 X X 4 ma to 0 ma ART In preparation C CSA C/US IS/XP CL.I, II Div. Gr.A- G/B-G, Zone, LC-M5 X 4 ma to 0 ma ART PROFIBUS PA SI00577O/98 SI0056O/98 74

75 Accessories Accessories Shutoff valve / NPT G/ / NPT 79 Max. working pressure [bar (psi)] Connection thread [d] Material Version 400 (5800) G/ C.8 (.0460) RA 36Ti (.457) RA, BA NPT/ C.8 (.0460) RD 36Ti (.457) RD, BD Siphon 05 Ø Ø63 G/ 79 G/ G/ /NPT SW7 SW7 /NPT 30 Ø Ø G/ No. Max. working pressure [bar (psi)] Max. operating temperature C ( F) in front of the siphon (process side) Connection thread [d] Material Version 04 (508) 0 (740) 60 (30) 400 (75) 300 (57) 0 (48) G/.0345 RA 36Ti (.457) RA, BA /NPT 36Ti (.457) BB G/.0345 RC /NPT.0345 RD 75

76 Accessories Welding necks and Weldin tool flanges On request Mounting bracket for wall and pipe mounting 5 ff M connector 7 ff 76

77 Configuration Data Sheet (ART and PROFIBUS PA Electronics) Configuration Data Sheet (ART and PROFIBUS PA Electronics) Level The following configuration data sheet has to be filled in and included with the order if the version "K" has been selected in feature "Calibration; unit" in the product structure. Pressure Engineering Unit Output unit (scaled unit) mbar mm O mmg Pa Mass Length Volume Volume Percent bar m O kpa ft O kgf/cm MPa kg m l gal % psi in O t dm hl Igal lb cm mm m 3 ft 3 ft in 3 inch Empty pressure [a]: Low pressure value (empty) [pres. eng. unit] Full pressure [b]: igh pressure value (full) [pres. eng. unit] Empty calibration [a]: Low level value (empty) [Skaled unit] Full calibration [b]: igh level value (full) [Skaled unit] Example (b) 300 mbar (4.5 psi) 3 m (9.8 ft) (a) 0 mbar 0 m Display st value display nd value display Main value None (Default) Main value [%] Pressure Current [ma] (only ART) Temperature Depending on sensor and communication variant Damping Damping: sec (Default sec) 77

78 Configuration Data Sheet (ART and PROFIBUS PA Electronics) Pressure The following configuration data sheet has to be filled in and included with the order if the version "J" has been selected in feature "Calibration; unit" in the product structure. Pressure engineering unit mbar mm O mmg Pa bar m O kpa ft O kgf/cm MPa psi in O Calibration range/output Low range value (LRV): Upper range value (URV): [pressure engineering unit] [pressure engineering unit] Display st value display nd value display Main value None (Default) Main value [%] Pressure Current [ma] (only ART) Temperature Depending on sensor and communication variant Damping Damping: sec (Default sec) Smallest calibratable span (preset at the factory) 9 ff. 78

79 Configuration Data Sheet (Analog Electronics) Configuration Data Sheet (Analog Electronics) Pressure The following configuration data sheet has to be filled in and included with the order if the version "J" has been selected in feature "Calibration; unit" in the product structure. Pressure Engineering Unit mbar mm O mmg Pa bar m O kpa ft O kgf/cm MPa psi in O Calibration range/output Low range value (LRV): Upper range value (URV): [pressure engineering unit] [pressure engineering unit] Display st value display nd value display Main value None (Default) Depending on sensor and communication variant Damping Damping: sec (Default sec) Smallest calibratable span (preset at the factory) 9 ff. 79

80 PROCESS AUTOMATION PROTECTING YOUR PROCESS Worldwide eadquarters Pepperl+Fuchs Gmb Mannheim Germany Tel info@de.pepperl-fuchs.com For the Pepperl+Fuchs representative closest to you check TI00436O/98/EN/7. FM7. Subject to modifications Copyright PEPPERL+FUCS Printed in Germany DOCT-98B 07/05

Cerabar M PMC51, PMP51, PMP55

Cerabar M PMC51, PMP51, PMP55 Technical Information Cerabar M PMC51, PMP51, PMP55 Process pressure measurement Pressure transmitter with ceramic and metal sensors; Modular design and easy operation; With analog or HART electronics

More information

Cerabar M PMC41/45, PMP41/45/46/48

Cerabar M PMC41/45, PMP41/45/46/48 Technical Information Cerabar M PMC41/45, PMP41/45/46/48 Pressure transmitters With ceramic and metal sensors Overload-resistant and function-monitored With analog, HART or PROFIBUS PA electronics Application

More information

Cerabar M PMC41/45, PMP41/45/46/48

Cerabar M PMC41/45, PMP41/45/46/48 Technical Information Cerabar M PMC41/45, PMP41/45/46/48 Pressure transmitters With ceramic and metal sensors Overload-resistant and function-monitored With analog, HART or PROFIBUS PA electronics Application

More information

OPTIBAR P 1010 C Technical Datasheet

OPTIBAR P 1010 C Technical Datasheet Technical Datasheet Pressure transmitter with recessed diaphragm for general applications Wide variety thanks to modular design Measuring ranges up to 250 bar / 3750 psi High overload and temperature stability

More information

Cerabar S PMC71, PMP71, PMP75

Cerabar S PMC71, PMP71, PMP75 Technical Information Cerabar S PMC71, PMP71, PMP75 Process pressure measurement Pressure transmitter with ceramic and metal sensors Overload-resistant and function-monitored; Communication via HART, PROFIBUS

More information

Technical Information Deltabar FMD71, FMD72

Technical Information Deltabar FMD71, FMD72 TI01033P/00/EN/04.14 7143971 Products Solutions Services Technical Information Deltabar FMD71, FMD7 Level measurement with electronic differential pressure Electronic differential pressure transmitter

More information

Cerabar S PMC71, PMP71/72/75

Cerabar S PMC71, PMP71/72/75 Technical Information Cerabar S PMC71, PMP71/72/75 Pressure transmitter with ceramic and metal sensors Overload-resistant and function-monitored; Communication via HART, PROFIBUS PA or FOUNDATION Fieldbus

More information

Technical Information Deltabar FMD71, FMD72

Technical Information Deltabar FMD71, FMD72 TI01033P/00/EN/05.15 71817 Products Solutions Services Technical Information Deltabar FMD71, FMD7 Level measurement with electronic differential pressure Electronic differential pressure transmitter with

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens A 207 Overview Application The SITRANS P Compact pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials

More information

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0. Pressure Transmitter for Marine and Offshore Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0. % FSO Nominal pressure from 0... 40 mbar up to 0... 0 bar Output signals -wire:

More information

Technical Information Cerabar PMC11, PMC21, PMP11, PMP21

Technical Information Cerabar PMC11, PMC21, PMP11, PMP21 TI01133P/00/EN/05.17 71353705 Products Solutions Services Technical Information Cerabar PMC11,,, Process pressure measurement Pressure transducer with ceramic and metal sensors Application The Cerabar

More information

Cerabar S PMC71, PMP71, PMP75

Cerabar S PMC71, PMP71, PMP75 Technical Information Cerabar S PMC71, PMP71, PMP75 Process pressure measurement Pressure transmitter with ceramic and metal sensors Overload-resistant and function-monitored; Communication via HART, PROFIBUS

More information

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0. LMP 07 Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % / 0. % FSO Nominal pressure from 0... mho up to 0... 50 mho Output signals -wire: 4... 0 ma -wire: 0...

More information

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor Precision- Pressure Transmitter for Food ndustry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to EC 60770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 40 bar Output

More information

Deltapilot M FMB50/51/52/53

Deltapilot M FMB50/51/52/53 Technical Information Deltapilot M FMB50/51/52/53 Hydrostatic level measurement Pressure sensor with the CONTITE TM measuring cell Condensate-resistant offering long-term stability; communication via HART,

More information

Differential pressure

Differential pressure Differential pressure 9 Overview Page 200 VEGADIF 65 Page 202 Chemical seal Page 204 Accessory Page 208 199 VEGADIF For differential pressure, level and flow measurements Measuring principle The sensor

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and

More information

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement Model LH-20 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater

More information

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0. Precision Pressure Transmitter for Food ndustry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to EC 60770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 40 bar Output

More information

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor INDUSTRIAL INSTRUMENTS AND CONTROLS SPECIALIST Kent-Taylor 2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters Features Include Base accuracy : ±0.075% Span limits

More information

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement Model LH-20 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater

More information

Hydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN

Hydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN Hydrostatic Continuous level measurement 8 Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 187 Hydrostatic Level and pressure measurement Measuring principle The pressure

More information

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure Siemens AG 204 Overview The pressure transmitter SITRANS P220 measures the gauge pressure of liquids, gases and vapors. Stainless steel measuring cell, fully welded Measuring ranges 2.5 to 600 bar (36.3

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens AG 07 Overview Function U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/ Equipotential bonding Diaphragm The pressure

More information

Expert Hydrostatic Level Transmitters

Expert Hydrostatic Level Transmitters Expert Hydrostatic s General Features MJK Expert hydrostatic level transmitters are designed for level measurement by submerging the transmitter in open channels, drains and tanks. Expert hydrostatic level

More information

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement Model LH-20 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater

More information

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure Z series for gage pressure Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection

More information

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. Supplied with an electric input signal of 4 to 20

More information

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition Siemens AG 07 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure

More information

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements

More information

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05 IDL0 Battery Powered Precision Digital Gauge for Leak Testing Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger

More information

Differential Pressure Transmiter

Differential Pressure Transmiter Differential Pressure Transmiter Description The is an economical alternative to established differential pressure transmitters. It combines state of the art electronics and a high performance sensor;

More information

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview f gauge pressure Siemens AG 010 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection

More information

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

Type N-10, N-11 Hazardous Area Non-incendive Transmitters Electronic Pressure Catalog > Hazardous Area > N-10, N-11 Type N-10, N-11 Hazardous Area Non-incendive Transmitters Applications Natural gas compressors Wellhead monitoring Pipeline pressure General industrial

More information

Technical Information Deltabar S PMD75, FMD77, FMD78

Technical Information Deltabar S PMD75, FMD77, FMD78 TI00382P/00/EN/28.17 71374973 Products Solutions Services Technical Information Deltabar S PMD75, FMD77, FMD78 Differential pressure measurement and pressure measurement Differential pressure transmitter

More information

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

DM01. Please visit our website:  Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05 DM0 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing

More information

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765 Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765 Application Single-acting positioner for attachment to pneumatic control valves. Supplied with either an electric input signal from

More information

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.

More information

High-performance submersible pressure transmitter For level measurement Model LH-10

High-performance submersible pressure transmitter For level measurement Model LH-10 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well

More information

Gas density monitor With integrated transmitter Model GDM-100-TI

Gas density monitor With integrated transmitter Model GDM-100-TI SF 6 gas solutions Gas density monitor With integrated transmitter Model GDM-100-TI grid Products WIKA data sheet SP 60.05 for further approvals see page 5 Applications Gas density monitoring of closed

More information

How to specify a product. Process Sensors and Mechanical Instruments

How to specify a product. Process Sensors and Mechanical Instruments How to specify a product Process Sensors and Mechanical Instruments Keep the overview. Here is some guideline information on how to specify our products. Intended as supplementary help to specification

More information

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI Siemens AG 06 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure

More information

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor.  Type: ETd 04. class 0.05 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 100 mbar up to 0... 400 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing

More information

ATM.1ST/Ex - High Precision Transmitter

ATM.1ST/Ex - High Precision Transmitter Pressure Transmitter - ATEX / IECEx certified ATM.1ST/Ex - High Precision Transmitter CUSTOMER BENEFITS Certificate: ATEX, IECEx & EAC High measurement accuracy is ensured by sophisticated digital temperature

More information

Programmable pressure and temperature transmitters PTM/RS485

Programmable pressure and temperature transmitters PTM/RS485 Programmable pressure and temperature transmitters PTM/RS485 Version: 26.06.2014 Technical Specifications Pressure measuring range (bar) 0.1... 0.5 > 0.5 2 > 2 25 Overpressure 3 bar 3 x FS ( 3 bar) 3 x

More information

High-performance submersible pressure transmitter For level measurement Model LH-10

High-performance submersible pressure transmitter For level measurement Model LH-10 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well

More information

Torque Tube TB300 Digital Transmitters

Torque Tube TB300 Digital Transmitters Page 1 of 7 7E.300-E Issue 4-2009 Description Series TB300 torque tube liquid level instruments utilize the buoyancy exerted on a displacer when immersed in a liquid. The buoyancy on the displacer is proportional

More information

ATM.ECO - Analog Pressure Transmitter

ATM.ECO - Analog Pressure Transmitter Pressure Transmitter ATM.ECO - Analog Pressure Transmitter CUSTOMER BENEFITS Entry level series into precision pressure measurement High measurement accuracy is ensured by sophisticated digital temperature

More information

Programmable pressure and temperature transmitters PTM/RS485

Programmable pressure and temperature transmitters PTM/RS485 Programmable pressure and temperature transmitters PTM/RS485 Version: 03-28-2012 Technical Specifications Pressure measuring range (bar) 0.1... 0.5 > 0.5 2 > 2 25 Overpressure 3 bar 3 x FS ( 3 bar) 3 x

More information

Deltabar M PMD55. Technical Information

Deltabar M PMD55. Technical Information Technical Information Deltabar M PMD55 Differential pressure measurement Differential pressure transmitter with metal sensor Communication via HART, PROFIBUS PA or FOUNDATION Fieldbus Application The Deltabar

More information

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing Ø

More information

9700 Transmitter Submersible hydrostatic level transmitter

9700 Transmitter Submersible hydrostatic level transmitter Specification sheet IP0078 October 2007 Level 9700 Transmitter Submersible hydrostatic level transmitter Description The 9700 series hydrostatic level transmitter is designed to perform in the most arduous

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.

More information

ATM.ECO/IS - Analog Transmitter with Temperature compensation

ATM.ECO/IS - Analog Transmitter with Temperature compensation Pressure Transmitter - FM / FM-C certified ATM.ECO/IS - Analog Transmitter with Temperature compensation CUSTOMER BENEFITS Certificate: FM, FM-C & IECEx & ATEX Entry level series into precision pressure

More information

JUMO dtrans p30 Pressure Transmitter

JUMO dtrans p30 Pressure Transmitter 609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +49 661 600-0 Fax: +49 661 600-607 Phone: +44 179 6 55 Data Sheet 40466 Page 1/6 JUMO dtrans p0 Pressure Transmitter General application Pressure

More information

ATM - Analog Pressure Transmitter

ATM - Analog Pressure Transmitter Pressure Transmitter ATM - Analog Pressure Transmitter CUSTOMER BENEFITS Fast customization thanks to configurable product design Demountable electrical connector option to allow adjustment of zero and

More information

ATM/Ex - Intrinsically Safe Analog Pressure Transmitter - ATEX / IECEx Certified

ATM/Ex - Intrinsically Safe Analog Pressure Transmitter - ATEX / IECEx Certified Intrinsically safe pressure transmitters ATM/Ex - Intrinsically Safe Analog Pressure Transmitter - ATEX / IECEx Certified CUSTOMER BENEFITS Certificate: ATEX & IECEx Fast customization thanks to configurable

More information

ED 701 Hygenic Pressure Transmitter

ED 701 Hygenic Pressure Transmitter ED 701 Hygenic Pressure Transmitter Hygienic process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response time < 25 ms (Option

More information

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications Technical Datasheet D Series SMART Pressure Transmitter Model: DPC-2000 Key Features ATEX - Flameproof and Intrinsically Safe IECEx - Flameproof and Intrinsically Safe SIL 2 certificate Compliant to NAMUR

More information

Pressure Transmitter P41

Pressure Transmitter P41 SENSORS FOR AND BIOPHARMA. Product Information P41 Pressure Transmitter P41 Application/Specified usage Pressure measurement in pipes and tanks For process temperatures up to 250 C (428 F) with optional

More information

Differential Pressure Transmitter deltabar S PMD 25 K for use in Nuclear Power Plants

Differential Pressure Transmitter deltabar S PMD 25 K for use in Nuclear Power Plants Technical Information TI 330P/00/en Differential Pressure Transmitter deltabar S PMD 25 K for use in Nuclear Power Plants Deltabar S with silicon sensor overload resistant with function monitoring Application

More information

Pressure Switches Application Guideline

Pressure Switches Application Guideline Pressure Switches Application Guideline Product Overview The Fema Pressure Switch product portfolio provides devices suitable for many applications. The portfolio contains Special functions and equipment

More information

Technical Information Cerabar PMP11, PMP21

Technical Information Cerabar PMP11, PMP21 TI01133P/00/EN/02.16 71326741 Products Solutions Services Technical Information Cerabar, Process pressure measurement Pressure transducer with metal sensors Application The Cerabar is a pressure transducer

More information

ATM/Ex - Analog Pressure Transmitter

ATM/Ex - Analog Pressure Transmitter Pressure Transmitter - ATEX certified ATM/Ex - Analog Pressure Transmitter CUSTOMER BENEFITS Certificate: ATEX & EAC Fast customization thanks to configurable product design Demountable electrical connector

More information

SITRANS. Pressure transmitter SITRANS P, Z series for gauge and absolute pressure. Introduction. Safety instructions 2.

SITRANS. Pressure transmitter SITRANS P, Z series for gauge and absolute pressure. Introduction. Safety instructions 2. Introduction 1 Safety instructions 2 SITRANS Pressure transmitter SITRANS P, Z series for gauge and absolute pressure 7MF1564 Description 3 Assembly and connection 4 Technical data 5 Dimensional drawings

More information

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.:

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.: Smart level probe type APC-2000ALW/L Programmable zero shift, range and damping ratio 4...20 ma output signal + HART protocol Accuracy 0,16% Local display Intrinsic safety certificate (ATEX, IECEx) II

More information

Siemens AG psi (6 bar) 145 psi (10 bar) 464 psi (32 bar) 1450 psi (100 bar) 3626 psi (250 bar) 8700 psi (600 bar) psi (800 bar)

Siemens AG psi (6 bar) 145 psi (10 bar) 464 psi (32 bar) 1450 psi (100 bar) 3626 psi (250 bar) 8700 psi (600 bar) psi (800 bar) Technical specifications SITRANS P, DS III series Input Measured variable Spans (infinitely adjustable) or nominal measuring range and max. permissible test pressure HART Gauge pressure Span (min.... max.)

More information

Pressure transmitter PASCAL Ci4

Pressure transmitter PASCAL Ci4 Pressure transmitter PASCAL Ci4 for general application,type Series CI4100 Features Pressure transmitter for the measuring of relative and absolute pressures of gases, vapors and liquids High-resolution

More information

Technical Information Ceraphant PTP31B

Technical Information Ceraphant PTP31B TI01130P/00/EN/02.16 71336342 Products Solutions Services Technical Information Ceraphant PTP31B Process pressure measurement Pressure switch for safe measurement and monitoring of absolute and gauge pressure

More information

Cerabar T PMC131, PMP131, PMP135

Cerabar T PMC131, PMP131, PMP135 Technical Information Cerabar T, PMP131, PMP135 Process pressure measurement Pressure transducer with ceramic and metallic sensors For absolute pressure and gauge pressure measurement up to 400 bar (6000

More information

Pressure Transmitter cerabar M PMC 41, PMC 45 cerabar M PMP 41, PMP 45

Pressure Transmitter cerabar M PMC 41, PMC 45 cerabar M PMP 41, PMP 45 Technical Information TI321P/00/en Pressure Transmitter cerabar M PMC 41, PMC 45 cerabar M PMP 41, PMP 45 Overload resistant pressure transmitter with a ceramic or metal sensor Optional: analogue, Smart

More information

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. An electric standardized signal of 4 to 20 ma or

More information

Parametrable / Programmable Pressure Transmitter

Parametrable / Programmable Pressure Transmitter Parametrable / Programmable Pressure Transmitter PTM/RS485 CUSTOMER BENEFITS High flexibility due to scalalbe pressure range Digital (RS485) and analogue (4-20mA) output signal in one sensor Available

More information

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm 0102 Model Number Features 2 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-12 Quick mounting bracket with dead stop BF 12 Mounting flange, 12 mm Technical Data specifications Switching

More information

NivuBar Plus II

NivuBar Plus II NivuBar Plus II Ceramic diaphragm Capacitive measuring cell 2-wire technology (output 4-20 ma) Integrated overload protection Extensive, almost front flush diaphragm Ex approval for zone 0 as standard

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 2 mm flush Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 2 mm Installation flush Output

More information

ATM.1ST. Pressure transmitters CUSTOMER BENEFITS

ATM.1ST. Pressure transmitters CUSTOMER BENEFITS Pressure transmitters ATM.1ST CUSTOMER BENEFITS High precision pressure sensor over the whole temperature range Electronic compensation Modular sensor structure (any process and electrical connections

More information

Technical Information Ceraphant PTP33B

Technical Information Ceraphant PTP33B TI01246P/00/EN/02.16 71336344 Products Solutions Services Technical Information Ceraphant PTP33B Process pressure measurement Pressure switch for safe measurement and monitoring of absolute and gauge pressure

More information

L3 Pressure and Level transmitter

L3 Pressure and Level transmitter SENSORS FOR AND BIOPHARMA. Product Information L3 L3 Pressure and Level transmitter Range of applications Hydrostatic Level measurement in dynamic temperature environments Pressure measurement in pipes

More information

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22. *09005087* DB_BA_EN_ME01_S Rev.A 12/16 *09005087* d e v e l o p i n g s o l u t i o n s Data Sheet and Operating Manual ME01 Digital manometer Table of Contents ME01 ## # 87 # HL S#### Dust explosion protection

More information

RTX 1000H Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control. Features

RTX 1000H Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control. Features GE Measurement & Control RTX 1000H Series Versatile Transmitters for a World of Pressure GE Measurement & Control is renowned for the design and manufacture of compact and rugged high performance pressure

More information

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications. Rated operating distance s n 5 mm 0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching

More information

Technical Data. Dimensions

Technical Data. Dimensions 00 Model Number Features mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,

More information

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm Dimensions M18x1 37 40 4 0102 24 LED Model Number Features 5 mm embeddable Usable up to SIL2 acc. to IEC 61508 Connection BN BU Accessories L+ L- EXG-18 Quick mounting bracket with dead stop BF 18 Mounting

More information

sitrans p Operating Instructions (de/en) Edition 03/2004

sitrans p Operating Instructions (de/en) Edition 03/2004 (de/en) Edition 03/2004 sitrans p Messumformer für Food, Pharma und Biotechnik Transmitters for food, pharmaceuticals and biotechnologgy 7FM8010 Contents Information for the operator...27 Important security

More information

MJK Expert 700 / 800 / 900 / 7070 / 7060 MJK Expert 1400 / 3400

MJK Expert 700 / 800 / 900 / 7070 / 7060 MJK Expert 1400 / 3400 MJK Expert 700 / 800 / 900 / 7070 / 7060 MJK Expert 1400 / 3400 Submersible Hydrostatic s Rugged and versatile 2.75 GB 2.75 Expert 090311 We reserve the right to continuously improve our products and make

More information

Submersible pressure sensor High-performance Model LH-20

Submersible pressure sensor High-performance Model LH-20 Level Submersible pressure sensor High-performance Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater monitoring Level measurement in open bodies of water

More information

ATM/GR. Electronic pressure switches CUSTOMER BENEFITS

ATM/GR. Electronic pressure switches CUSTOMER BENEFITS Electronic pressure switches ATM/GR CUSTOMER BENEFITS Pressure sensor with integrated switching contacts Modular sensor structure (any process and electrical connections can be combined) Manual readjustment

More information

Level sensing relative and absolute pressure transmitter type 712

Level sensing relative and absolute pressure transmitter type 712 Level sensing relative and absolute pressure transmitter type 712 Pressure range 0... 0.3-3 bar The level sensing pressure transmitter Type 712 is manufactured using an relative or absolute pressure measuring

More information

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries Series 2000 ALL STAINLESS DESIGN EASY CALIBRATION WITHOUT TEST PRESSURE BY 3 PUSH BUTTONS ACCURACY 0,1% 4-20 ma AND HART PROTOCOL ATEX II

More information

GA24 Technical Datasheet

GA24 Technical Datasheet GA24 Technical Datasheet Variable-area flowmeter Sturdy construction for several applications Local indication without auxiliary power Replaceable mounting parts KROHNE CONTENTS GA24 1 Product features

More information

Technical Data Sheet MF010-O-LC

Technical Data Sheet MF010-O-LC Technical Data Sheet MF010-O-LC - 1 - 1. Properties The oxygen measuring system MF010-O-LC determines the oxygen content in gas mixtures up to a temperature of 250 C. It is particularly suitable for the

More information

Level transmitter LT 100

Level transmitter LT 100 KROHNE 09/2001 7.02363.21.00 GR/PRINTO Level transmitter LT 100 Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters

More information

A Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >

A Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit > A Higher Level of Performance Data Sheet Pressure and Level Transmitters For more information, please visit > www.hawkmeasure.com Description Intelligent pressure and level transmitters for all industries

More information

SonoMeter 30 Energy Meters

SonoMeter 30 Energy Meters Data Sheet SonoMeter 30 Energy Meters Description The Danfoss SonoMeter 30 is a range of ultrasonic, compact energy meters intended for measuring energy consumption in heating and cooling applications

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable

More information

2600T Series Pressure Transmitter

2600T Series Pressure Transmitter Data Sheet 2600T Series Pressure Transmitter Model 261GC/GG/GJ/GM/GN Gauge Model 261AC/AG/AJ/AM/AN Absolute with direct mount seal Base accuracy: ±0.15 % Span limits 0.3 to 60000kPa; 1.2inH 2 O to 8700psi

More information

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC Mechatronic pressure measurement Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC WIKA data sheet PV 35.41 Process Compact Series Applications Differential pressure monitoring

More information

780S Ultra High Purity Series

780S Ultra High Purity Series Smart Ultra High Purity Thermal Gas Mass Flow Meter Features Measures mass flow directly, no seperate temperature or pressure inputs required Field adjustment of critical flow meter settings via on-board

More information