V83 series Redundant valve manifold systems - Modular with bypass 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability
|
|
- Frederica McCormick
- 5 years ago
- Views:
Transcription
1 V8 series Redundant valve manifold systems - Modular with bypass oo Safety, oo Availability and oo Safety and Availability > > Modular design - Maxseal valves > > able terminations inside coil housing > > ypass function enables valve removal online > > SIL certified components and system > > Stainless steel visual status indicators and exhaust guards as standard > > International approvals > > Stainless steel construction > > Utilizing industry proven technology Technical features Medium: Filtered, non-lubricated or dry compressed air, instrument air nitrogen and other non-flammable neutral dry fluids Operation: / Direct solenoid operated poppet valves ypass: 5/ Manual operated spool valve (lockable) Mounting position: Valves vertical only Operating pressure:... 0 bar (... 5 psi) Flow: Standard valves l/min High flow valves l/min details see page Port size: G /, / NPT, G /, / NPT Additional filter: Installation of an in-line filter is recommended (in the direction of flow from the actuator to the RVM). Temperature range: Up to ( F), see option selector page Air supply must be dry enough to avoid ice formation at temperatures below (+5 F) Temperature solenoid: See option selector and corresponding valve data sheets Materials: Manifold and valve: stainless steel.0 (6 L) Seals: NR Internal parts: stainless steel.0 (6 L) oo with bypass valve exhaust guards and indicators oo with bypass valve exhaust guards and indicators oo with bypass valve *) exhaust guards and indicators W oo I I W oo I W oo I6 V W I V W V I5 I I I V V V W I V V I I I I ypass valve I Indicators V Solenoid actuated valves W Shuttle valves ( OR function) *) for oo V & V = channel V = channel V = channel *) for oo V = channel V = channel V = channel V = channel Please have a look to instructions without notice, the specifications given in this document. (0-577c) 0 Norgren GmbH 6/5 en
2 V8 series Redundant valve manifold systems - Modular with bypass oo Safety, oo Availability and oo Safety and Availability Option selector V8 S000 0 Valve function Substitute out of normally closed out of normally closed out of normally closed 5 Flow Substitute Standard High Port sizes Substitute G / (standard flow system) / NPT (standard flow system) G / (high flow system) / NPT (high flow system) Valve type Solenoid Voltage able Substitute Protection Entry Standard flow YXANPHS Exia V d.c. M 0 x,5 0 Y0ANPHS Exd V d.c. M 0 x,5 0 YZANPHS Exmbe V d.c. M 0 x,5 0 Y0ANPHMS Exd 0 V a.c. M 0 x,5 0 YZANPHMS Exmbe 0 V a.c. M 0 x,5 05 YXANPHS Exia V d.c. / NPT 06 Y0ANPHS Exd V d.c. / NPT 07 YZANPHS Exmbe V d.c. / NPT 08 Y0ANPHMS Exd 0 V a.c. / NPT 09 YZANPHMS Exmbe 0 V a.c. / NPT 0 High flow Y0AMMHS Exd V d.c. M 0 x,5 YZAMMHS Exmbe V d.c. M 0 x,5 Y0AMMHMS Exd 0 V a.c. M 0 x,5 YZAMMHMS Exmbe 0 V a.c. M 0 x,5 5 Y0AMMHS Exd V d.c. / NPT 7 YZAMMHS Exmbe V d.c. / NPT 8 Y0AMMHMS Exd 0 V a.c. / NPT 9 YZAMMHMS Exmbe 0 V a.c. / NPT 0 Note; Please advise when ordering if SA certification is required ountry of manufacture Norgren internal use Indicators Visual valve status indicators in stainless steel - standard option; to be included in he scope of supply Visual valve status indicators in plastic - optional; to be included in the scope of supply No valve status indicator optional; replaced with plugs (stainless steel) Temperature/ Pressure range /, bar bar (... 5 psi) Substitute Silencers Temperature Substitute Exhaust guard (standard) Plastic silencers to replace exhaust guards Stainless steel silencers to replace exhaust guards ypass valve Temperature Substitute Stainless steel Stainless steel Flow rates and valve combinations Flow direction (port to port) Standard flow systems ypass mode Operation mode High flow systems ypass mode Operation mode oo 9709 x Y*ANPH*S 9709 x Y*AMMH*S» *) [l/min] » *) [l/min] oo 9709 x Y*ANPH*S 9709 x Y*AMMH*S» *) [l/min] » *) [l/min] oo 9709 x Y*ANPH*S 9709 x Y*AMMH*S» *) [l/min] » *) [l/min] *) Flow characteristics conforms to ISO658 from port (bypass valve) to port (sub-base) [6» 5 bar], see page *) Flow characteristics conforms to ISO658 from port (sub-base) to port (sub-base or bypass valve) [0» 0 bar], see page en without notice, the specifications given in this document. (0-577c) 0 Norgren GmbH 6/5
3 V8 series Redundant valve manifold systems - Modular with bypass oo Safety, oo Availability and oo Safety and Availability Standard and optional accessories Accessories - Standard (Included in the scope of supply) Exhaust guard *) Visual indicators (stainless steel) 8 Accessories - Optional Other silencers, plastic indicator and plugs Silencer (stainless steel) *) Silencer (plastic) *) Visual indicators (plastic) Adaptor 9 0 Plug plus Sealing washer Page Page 06 (G /, / NPT) (G /) (/ NPT) 06 (G /, / NPT) *) For indoors use *) For outdoors use Page Page Page Page 006 (G /) M/S (G /) 5VS--000 (/8 NPT) 0669 (G /, stainless steel) (/ NPT) /S (/ NPT) Adapter (/8 NPT to / NPT) *) (/ NPT, stainless steel) 008 (G /) M/S (G /) (stainless steel) Sealing washer *) (/ NPT) /S (/ NPT) (plastic) *) For indoors use; *) For outdoors use; *) Must be ordered separately; *) Must be ordered separately for G thread only 6/5 without notice, the specifications given in this document. (0-577c) 0 Norgren GmbH en
4 V8 series Redundant valve manifold systems - Modular with bypass oo Safety, oo Availability and oo Safety and Availability oo and oo with bypass (standard flow) Weight: 9 kg aluminium sub-base only, valves and accessories see refer page M ,5 90 ~ 9 ~ , ,5 57, , Valve Y*ANPHS and Y*ANPHS series Outlet port G / or / NPT Exhaust guard (sub-base), ports G / or / NPT ypass valve 9709 series 5 Exhaust guard (bypass valve), ports G / or / NPT 7 Inlet port G / or / NPT 8 Visual indicator, stainless steel as standard 9 Mounting holes 0 Mounting threads en without notice, the specifications given in this document. (0-577c) 0 Norgren GmbH 6/5
5 V8 series Redundant valve manifold systems - Modular with bypass oo Safety, oo Availability and oo Safety and Availability oo with bypass (standard flow) Weight: 8,7 kg sub-base only, valves and accessories see refer page A ø M , ,5 56 A , ,5 57, ~ ~ Valve Y*ANPHS and Y*ANPHS series Outlet port G / or / NPT Exhaust guard (sub-base), ports G / or / NPT ypass valve 9709 series 5 Exhaust guard (bypass valve), ports G / or / NPT 7 Inlet port G / or / NPT 8 Visual indicator, stainless steel as standard 9 Mounting holes 0 Mounting threads 6/5 without notice, the specifications given in this document. (0-577c) 0 Norgren GmbH en
6 V8 series Redundant valve manifold systems - Modular with bypass oo Safety, oo Availability and oo Safety and Availability oo and oo with bypass (high flow) Weight: 9 kg sub-base only, valves and accessories see refer page M ~ ~ 9 60 ø ,5 75 7,5 60, , (5) Valve Y*AMMHS and Y*AMMHS series Outlet port G / or / NPT Exhaust guard (sub-base), ports G / or / NPT ypass valve 9709 series 5 Exhaust guard (bypass valve), ports G / or / NPT 7 Inlet port G / or / NPT 8 Visual indicator, stainless steel as standard 9 Mounting holes 0 Additional mounting threads en without notice, the specifications given in this document. (0-577c) 0 Norgren GmbH 6/5
7 90 V8 series Redundant valve manifold systems - Modular with bypass oo Safety, oo Availability and oo Safety and Availability oo with bypass (high flow) Weight: 7,9 kg sub-base only, valves and accessories see refer page M ø A 09, ,5 0 ~ 7 A 06 ~ ~ 7 8 9, , Valve Y*AMMHS and Y*AMMHS series Outlet port G / or / NPT Exhaust guard (sub-base), ports G / or / NPT ypass valve 9709 series 5 Exhaust guard (bypass valve), ports G / or / NPT 7 Inlet port G / or / NPT 8 Visual indicator, stainless steel as standard 9 Mounting holes 0 Mounting threads 6/5 without notice, the specifications given in this document. (0-577c) 0 Norgren GmbH en
8 Y*ANPH*S standard flow valve > > Standard flow range (600 l/min) > > Direct acting / spring return to safe condition > > ertifications: IEEx, ATEX, FM, SA, GOST-R, GOST-K, OE, IN-METRO, KOSHA > > Suited for outdoor use under critical environment conditions (see solenoid list) Technical features Medium: Filtered, non-lubricated or dry compressed air, instrument air nitrogen and other non-flammable neutral dry fluids Operation: / Direct solenoid operated poppet valves Port size: Flanged Orifice: 5 mm Operating pressure: 0... bar ( psi) ( bar ( psi) with SA certification) Fluid/AmbientTemperature: See table below Air supply must be dry enough to avoid ice formation at temperatures below (+5 F) For outdoor installation please protect all connections against moisture ingress! Materials: ody: stainless steel.0 (6 L) oil housing: stainless steel.0 (6 L) Seals: NR Internal parts: stainless steel.0 (6 L) Technical data Symbol Power consumption Rated current ertifications Temperature range Electrical Model V d.c. 0 V a.c. V d.c. 0 V a.c. Media Ambient connection (W) (VA) (ma) (ma) FM ATEX ( ) ( ) (conduit) 0, 5 Ex II GD, Ex ia II T6 ( ), T ( ) M 0 YXANPHS 5 lass, Divison, Ex II GD, Ex d II T6 ( ), T ( ) M 0 Y0ANPHS Groups, and D 5 Ex mbe II GD, Ex mbe II T ( ) M 0 YZANPHS,5 0 lass, Divison, Ex II GD, Ex d II T6 ( ), T ( ) M 0 Y0ANPHMS Groups, and D,5 0 Ex mbe II GD, Ex mbe II T ( ) M 0 YZANPHMS 0, 5 Ex II GD, Ex ia II T6 ( ), T ( ) / NPT YXANPHS 5 lass, Divison, Ex II GD, Ex d II T6 ( ), T ( ) / NPT Y0ANPHS Groups, and D 5 Ex mbe II GD, Ex mbe II T ( ) / NPT YZANPHS,5 0 lass, Divison, Ex II GD, Ex d II T6 ( ), T ( ) / NPT Y0ANPHMS Groups, and D,5 0 Ex mbe II GD, Ex mbe II T ( ) / NPT YZANPHMS en without notice, the specifications given in this document. (0-577c) 0 Norgren GmbH 6/5
9 Y*ANPH*S standard flow valve 50 ø59 ø5, ,5 ø9, ø9 6 6 Electrical connection M0 x,5 or / NPT Ports plugged G /: Hexagon head plug / NPT: Hexagon socket set plug ircuit diagrams 6/5 without notice, the specifications given in this document. (0-577c) 0 Norgren GmbH en
10 Y*AMMH*S high flow valves > > High flow range (500 l/min) > > Direct acting / spring return to safe condition > > Suited for outdoor use under critical environment conditions (see solenoid list) > > ertifications: IEEx, ATEX, FM, SA, GOST-R, GOST-K, OE, IN-METRO, KOSHA Technical features Medium: Filtered, non-lubricated or dry compressed air, instrument air nitrogen and other non-flammable neutral dry fluids Operation: / Direct solenoid operated poppet valves Port size: Flanged Orifice: 8 mm Operating pressure: 0... bar ( psi) ( bar ( psi) SA) Fluid/Ambient temperature: See table below Depending on solenoid system Air supply must be dry enough to avoid ice formation at temperatures below (+5 F) For outdoor installation please protect all connections against moisture ingress! Materials: ody: stainless steel.0 (6 L) oil housing: stainless steel.0 (6 L) Seals: NR Internal parts: stainless steel.0 (6 L) Technical data Symbol Power consumption V d.c. 0 V a.c. (W) (VA) Rated current ertifications V d.c. 0 V a.c. (ma) (ma) FM 7,8 5 lass, Divison, Groups, and D Temperature range Electrical Model Media Ambient connection ATEX ( ) ( ) (conduit) Ex II GD, Ex d II T6 ( ), T ( ) M 0 Y0AMMHS 7,8 5 Ex mbe II GD, Ex mbe II T ( ) M 0 YZAMMHS 8,5 79 lass, Divison, Groups, and D Ex II GD, Ex d II T6 ( ), T ( ) M 0 Y0AMMHMS 8,5 79 Ex mbe II GD, Ex mbe II T ( ) M 0 YZAMMHMS 7,8 5 lass, Divison, Groups, and D Ex II GD, Ex d II T6 ( ), T ( ) / NPT Y0AMMHS 7,8 5 Ex mbe II GD, Ex mbe II T ( ) / NPT YZAMMHS 8,5 79 lass, Divison, Groups, and D Ex II GD, Ex d II T6 ( ), T ( ) / NPT Y0AMMHMS 8,5 79 Ex mbe II GD, Ex mbe II T ( ) / NPT YZAMMHMS en without notice, the specifications given in this document. (0-577c) 0 Norgren GmbH 6/5
11 Y*AMMH*S high flow valves 50 ø59 7 5, ,5, , ,5 Electrical connection M0 x,5 or / NPT ircuit diagrams 6/5 without notice, the specifications given in this document. (0-577c) 0 Norgren GmbH en
12 9709 bypass valve for standard and high flow systems > > No open port cross over position during lever movement > > Simple design of soft seal spool system > > Reliable operation even with minimal air flow > > Padlock with two keys > > Lockable manual operator with detent as standard Technical features Medium: Filtered, non-lubricated or dry compressed air, instrument air nitrogen and other non-flammable neutral dry fluids Operation: Manual actuated spool valves Port size: see below, according to select system (standard flow or high flow) Operating pressure: bar Fluid/Ambient temperature: ( F), Air supply must be dry enough to avoid ice formation at temperatures below (+5 F) For outdoor installation please protect all connections against moisture ingress! Materials: Housing: hard anodized aluminium.065 or stainless stainless steel.0 (6 L) Seals: NR (special perbunan) or HNR Technical data Temperature range: Symbol 5 Port size Flow Material Weight Dimension Model, and 5 and housing seals (kg) No. G/ flange standard stainless steel NR, / NPT flange standard stainless steel NR, G/ flange high stainless steel NR, / NPT flange high stainless steel NR, Temperature range: Symbol 5 Port size Flow Material Weight Dimension Model, and 5 and housing seals (kg) No. G/ flange standard stainless steel HNR, / NPT flange standard stainless steel HNR, G/ flange high stainless steel HNR, / NPT flange high stainless steel HNR, en without notice, the specifications given in this document. (0-577c) 0 Norgren GmbH 6/5
13 9709 bypass valve for standard and high flow systems Standard flow valves 5 5 5, 9,7 5 5 ~8 ~7 ~8,5 0,5 7 5/ M5 7,5 ~5 High flow valves , 6, 5 ~7 ~ ~5 6 5/ M6 ~77 Inlet and exhaust ports G / or / NPT Namur flamge plate Inlet and exhaust ports G / or / NPT 6/5 without notice, the specifications given in this document. (0-577c) 0 Norgren GmbH en
14 V8 series Redundant valve manifold systems - Modular with bypass oo Safety, oo Availability and oo Safety and Availability Exhaust guard (plastic) - standard option G Visual indicator (stainless steel) - standard option ø D ød G ød Visual colour Red (unactuated) Green (actuated) Suitable for G Ø D Weight (g) Model / G /, / NPT 0 6, / G /, / NPT, Ø D Ø D G Weight (g) Model G / 8, / NPT Silencer (plastic) Silencer (stainless steel) G ø D G G Ø D Weight (g) Model G / 7 5,5 5,5,9 M/S / NPT 7 5,5 5,5,9 /S G / 67,5 M/S / NPT 67,5 /S Plug (stainless steel) G Weight (g) Model G / / NPT G / / NPT Visual indicator (plastic) G G Weight (g) Model G/ 0669 / NPT Sealing washer (plastic) Ø D Ø D Weight (g) Model /8 NPTF VS--000 Adapter (stainless steel) E ø D ø D Visual colour Red (unactuated) Green (actuated) ø D ø D G For plug ø D ø D E Weight (g) Model G /,5 7, G Weight (g) Model / NPT /8 NPT, en without notice, the specifications given in this document. (0-577c) 0 Norgren GmbH 6/5
15 V8 series Redundant valve manifold systems - Modular with bypass oo Safety, oo Availability and oo Safety and Availability Warning These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under»technical features/data«. efore using these products with fluids other than those specified, for non-industrial applications, life-support systems or other applications not within published specifications, consult IMI NORGREN. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. 6/5 without notice, the specifications given in this document. (0-577c) 0 Norgren GmbH en
SPCH/ Blowing block
> > for linear stretch blow moulding machines > > Compact and safe design > > Best suited for PET bottles up to litres, depending on cycle time Technical features Medium: Compressed air (purity class 3..3
More informationR18 General purpose pressure regulators
> > Port size: / & (ISO G, PTF) > > Can be installed at any point in the compressed air system without regard to accessibility pilot regulator can be installed in the most convenient location > > Accurate
More informationR84G - Excelon Plus Modular System Pressure regulators
> Port size: 3/8... 3/4 (ISO G/PTF) > Excelon Plus design allows in-line installation or modular installation with other Excelon Plus products > Easy to read flush mounted integrated pressure gauge as
More informationB74G - EXCELON Modular System General purpose filter/regulator
> Port size: /8... / (ISO G/PTF) > Excelon design allows in-line installation or modular installation with other Excelon products > Push to lock adjusting knob with optional tamper resistant accessory
More informationBL68 - Olympian Plus, plug-in system Filter/regulators and lubricators
>> Port size: 3/4... /2 (ISO G/ PTF) >> Complete air processing units pre-assembled, ready to install Technical features Medium: Compressed air only Maximum operating pressure: 7 bar (246 psi) Pressure
More informationVPPC02, VPPC08 3-way proportional pressure control valve, electronic closed loop control
VPPC, VPPC -ay proportional pressure control valve, > > Nominal diameter,, flange version G/ > > Visual function display (optional) > > Compact and lighteight design > > Field bus capable as part of a
More information4/2 way Pneumatic Solenoid Valve
4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11
More informationF68G - Olympian Plus plug-in system General purpose filter
> > Port size: /... / (ISO G/ PTF) > > Olympian Plus plug in system > > Large filter element area provides minimum pressure drop > > Effective liquid removal and positive solid particle filtration Technical
More informationB84G - Excelon Plus Modular System General purpose filter/regulator
> Port size: 3/8... 3/4 (ISO G/PTF) > Excelon Plus design allows in-line installation or modular installation with other Excelon Plus products > Push to lock adjusting knob with built in tamper resistant
More informationNugget 120 V14 Series
Nugget 0 V Series /2 & /3 Valves Solenoid and Pilot Operated G 1 4 High flow compact valves Sub-base and low profile manifolds Light weight, long life corrosion resistant materials Multipole and Fieldbus
More informationNugget 120 V14 Series
Nugget 0 V Series /2 & /3 Valves Solenoid and Pilot Operated G 1 4 High flow compact valves Sub-base and low profile manifolds Light weight, long life corrosion resistant materials Multipole and Fieldbus
More informationKM/31000 (Stainless steel end plates) Air bellows, single acting
KM/ (Stainless steel end plates) > > Ø... / inch (... mm) > > Very easy to install no alignment problems > > Almost frictionless operation > > No maintenance or lubrication > > Typical applications; actuator,
More informationModel range*1) Switching pressure difference
Pneumatic pressure switch electromechanical actuated -...00 bar, G/2 Microswitch with gold plated contacts Intrinsically safe operation Electrical connection: connector acc. to IN EN 7530-803 (form A)
More informationQuick Release Couplings 233 Series
Quick Release ouplings 233 Series 4mm - 9mm I/ hose 1 8" - 1 4" SP thread Low pressure drop across coupling High flow rate ompact construction One hand operation Robust construction Various connection
More informationPneumatic pressure switch 20DD
Sensor system: stainless steel 0,2 to 6 bar Microswitch with gold plated contacts (suitable for intrinsically safe operation) High accuracy (max. scattering < 1,5%) Excellent sealing properties (better
More informationCalibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New
> Series MD regulators Series MD pressure regulators New Ports with interchangeable cartridges: threaded (1/8, 1/4, /8) or integrated with super-rapid fitting for tube with Ø 6, 8 and 10 mm Versions: single,
More informationPower Valve: Precision Regulator. High precision, large capacity relief regulator
Power Valve: Precision Regulator Series VEX High precision, large capacity relief regulator port large exhaust capacity pressure reducing valve which utilizes a nozzle flapper mechanism available as air
More informationSOLENOID VALVES AND PNEUMATIC VALVES
9 S E R I E S Electropneumatically and pneumatically operated valves Series 9 Assembly with sub-base (ISO 5599/1 Standards) Sizes 1, 2 and 3 The Series 9 electropneumatically or pneumatically operated
More informationPneumatic valve islands
Pneumatic valve islands The MEGA solenoid air operated spool valve JOUCOMATIC offers a concept of solenoid air operated spool valves which can be fitted together to form islands. Due to its new patented
More informationAir preparation units
Overview Description Page Characteristics Dimensions Order instructions Type overview unit three-piece 44, 45, 48 52 6 unit two piece 44, 45, 48 52 6 Filter-regulator 44, 45, 48 53 6 Filter-water-separator
More informationMass Flow Controller (MFC) for Gases
Mass Flow Controller (MFC) for Gases Type 8713 can be combined with... Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy and repeatability
More informationINVERS. Solenoid coil 24VDC 12 VDC Exm Exd Explosion protection marking:
direct operated INVERSE function available Q max = 2 l/min p max = bar INVERS Description EPDB The direct operated proportional pressure relief valve is built as a slip-in cartridge fitted in a connecting
More information3-Way Safety Block DSV
3-Way Safety Block DSV DSV 10 - M DSV 10 - M - T-ball DSV 10 - EY 1. Description 1.1. GENERAL The 3-way safety block is used to shut off and discharge hydraulic accumulators or consumers. It complies with
More informationSeries MX pressure regulators 3/
CATALOGUE > Release 8.8 > Series MX regulators Series MX pressure regulators MX2 ports: G/8, G1/2, G/4 - MX ports: G/4, G1 Manifold ports: G1/2 (MX2 only) Modular - Available with built-in pressure gauges
More informationB84G - Excelon Plus Modular System General purpose filter/regulator
> Port size: 3/8" to 3/4" (PTF/ISO G) > Excelon Plus design allows in-line installation or modular installation with other Excelon Plus products > Push to lock adjusting knob with built in tamper resistant
More informationEMERGENCY SHUT-DOWN RELIABILITY ADVANTAGE
Your partner in Fluid Control Solutions EMERGENCY SHUT-DOWN RELIABILITY ADVANTAGE George Cao 06 May, 2011 1. ESD Overview Why Do You Need ESD Solution? Safety! Safety!! Safety!!! Safety Is a Must! The
More informationSeries 1, 3 and 4 Cv = /8" and 1/4" Ported Manually Operated Valves. 3-way/2-position, 5-way/2-position, 5-way/3position
Cv =.52 -.73 Series, 3 and 4 Cv =.52.3 /8" and /4" Ported Manually Operated Valves 3-way/2-position, 5-way/2-position and 5-way/3-position Ports /8 and /4" NPTF The Series (/8 & /4", 3-way/2-position and
More informationNon-Return Valves T55 Series
T55 Series In-Line, Non-Return Valves M5, 1 8", 1 2" BSPP, BSPT, NPT Permit free flow of air in one direction only Simple, reliable design Light weight Silicone free Low cracking pressure Technical ata
More informationSPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection
SPOOL VALVES pilot operated single/dual solenoid (mono/bistable function) ISO 07-8 mm - pad mounting body M connection x/ - / - / Series 0 ISO 07- (8 mm) FEATURES M connection on top of valve: reduces
More informationMass Flow Meter (MFM) for Gases
873 Mass Flow Meter (MFM) for Gases Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy Short response time Compact design and digital
More informationALF400 to 900, ALT-5/-9
Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Auto feed lube 00 00-0 00 00 00 900 - --IS- -9 AIR : OIL : Fluid Proof pressure Air. MPa 0. MPa.0 MPa (Note ) Operating pressure differential
More informationIntrinsically safe solenoid valves on/off controls - ATEX certification
www.atos.com Table E130-17/E Intrinsically safe solenoid valves on/off controls - ATEX certification valve body valve spool intrinsically safe solenoid electrical connector manual override DHW-0611/WP/6
More informationSolenoid valves VZWF, force pilot operated
Key features and overview Function Normally closed solenoid valve with diaphragm and forced lifting. When the solenoid is energised, the differential pressure from the secondary side of the diaphragm is
More informationISO Sub-bases. Port sizes G 1 /4 - G1 and 1 /4NPT - 1 /2NPT. Sub-bases tovdma specification, for ISO sizes #1, #2, #3 and #4
Port sizes 1 / - 1 and 1 /NPT - 1 /NPT Sub-bases tovd 3 specification, for ISO sizes #1, #, #3 and # Universal bases for ISO sizes #1 and #, side and bottom ported Technical Data edium: See individual
More informationSafety and Shut-off Block SAF/DSV
Safety and Shut-off Block SAF/DSV 1. DESCRIPTION 1.1. GENERAL The HYDAC safety and shut-off block is used to shut off and discharge hydraulic accumulators or consumers. It complies with the relevant safety
More informationBooster Regulator/Air Tank
Booster Regulator/Air Tank Increase factory air pressure by up to 4 times! Air-only operation requires no power supply, reduces heat generation, and Boost pressure allows easy installation. NEW Renewed
More informationFEPA PNEUMATICALLY AND SOLENOID ACTUATED VALVES, ONE UNIT MOUNTED TYPE VPG
PNEUMATICALLY AND SOLENOID ACTUATED VALVES, ONE UNIT MOUNTED TYPE VPG TECHNICAL CHARACTERISTICS Number of ways / positions : 3/2, 3/3, 5/2, 5/3, 5/4 Nominal sizes (ND) : 4, 6, 9, 12 Medium : compressed
More informationFULL STAINLESS STEEL EXPLOSION-PROOF SOLUTIONS OIL & GAS I OFFSHORE AND ONSHORE
FULL STAINLESS STEEL EXPLOSION-PROOF SOLUTIONS OIL & GAS I OFFSHORE AND ONSHORE ASCO Numatics ASCO Numatics is the world leader in design, manufacturer of solenoid valves and accessories for both offshore
More informationType 4708 Supply Pressure Regulator
Type 478 Pressure Regulator Application pressure regulators used to provide pneumatic measuring and control equipment with a constant air supply Set point ranges. to. bar ( to 4 psi). to bar (8 to 9 psi)
More informationPneumatic spool valve islands
Pneumatic spool valve islands P7.GB.R MEGA SPOOL VALVE ISLANDS MEGA pneumatic spool valve islands offer maximum performance along with flexibility, easy installation and simple operation. Due to their
More informationP33 Safety Exhaust Valve Externally Monitored. Bulletin 0700-B14 ENGINEERING YOUR SUCCESS.
P Externally Monitored ulletin 07004 ENGINEERING YOUR SUESS. Features Externally Monitored Function When applications demand a safe environment you can count on safety valves from Parker Hannifin. The
More informationMass Flow Controller (MFC) for Gases
Mass Flow Controller (MFC) for Gases Bypass MFC with capillary technology for nominal flow rates from 5 ml N /min to 15 l N /min Applicable for aggressive gases Compact design and digital communication
More informationSpecifications. Model VEX Operating style Fluid Proof pressure Max. operating pressure
Power Valve Regulator Valve Series 1 Large Capacity Relief Regulator 3 port large capacity poppet exhausting regulator equipped with a relief port the same size as the connection port. Specifications Model
More informationHand lever valves VHER
Hand lever valves VHER Hand lever valves VHER Key features Powerful Flexible Practical -M- Flow 170 3800 l/min 4/3-way valve mid-position closed mid-position exhausted mid-position pressurised Connections:
More informationMULTIPOL - VDMA. PNEUMATIC SPOOL VALVE ISLANDS VDMA ISO 02 - ISO 01 (G1/8 - G1/4) designed for connection to a PLC by multiwire cable
P8.G.R PEUATIC SPOOL VALVE ISLADS VDA - ISO - ISO (G/8 - G/) designed for connection to a PLC by multiwire cable ULTIPOL - VDA IPUT IPUT OUTPUT OUTPUT OUTPUT IPUT IPUT ULTIPOL - VDA Pneumatic spool valve
More informationMV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:
MV-01 2/2-way Solenoid Valve for Fluids Description: Features / Nominal diameters 1/4-2 / Pressure up to 10 bar / 24 V DC and all common AC variants / Forced-lifting The pilot-controlled full-way valve
More information3/2-way valve, Series CD07 Qn= 1400 l/min pipe connection compressed air connection output: G 1/4 - M14x1,5 suitable for ATEX
/-way valve, Series CD07 Version Spool valve, zero overlap Sealing principle soft sealing Working pressure min./max. -0.95 bar / 0 bar Ambient temperature min./max. -5 C / +80 C Medium temperature min./max.
More informationValves, manually operated
Valves, manually operated Valves, manually operated Key features VHEM-P K/O-3-PK-3 H-3-¼-B KH/O-3-PK3 TH/O-3-PK3 F-3-¼-B Innovative Versatile Reliable Easy to mount Small and compact for a wide range of
More informationSPOOL VALVES. ISO 15407/1 - Sizes Series PA568-GB-R3. All leafl ets available at:
SPOOL VLVS ISO 07/ - Sizes 0-0 Series 8-9 P68-GB-R ll leafl ets available at: www.ascojoucomatic.com FTURS These spool valves which comply with the VDM 6 standard offer the advantage of being smaller than
More informationValves, manually operated
Valves, manually operated Valves, manually operated Key features VHEM-P K/O-3-PK-3 H-3-¼-B KH/O-3-PK3 TH/O-3-PK3 VHEM-L F-3-¼-B Innovative Versatile Reliable Easy to mount Small and compact for a wide
More informationSafety and Shut-off Block SAF/DSV
1. DESCRIPTION 1.1. GENERAL The HYDAC safety and shut-off block is used to shut off and discharge hydraulic accumulators or user units. It complies with the relevant safety standards in accordance with
More informationSafety and Shut-off Block SAF/DSV
Safety and Shut-off Block SAF/DSV 1. Description 1.1. GENERAL The HYDAC safety and shut-off block is used to shut off and discharge hydraulic accumulators or consumers. It complies with the relevant safety
More informationAuto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9
Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Fluid Proof pressure Operating pressure differential range (Difference between tank pressure and line pressure) Vibration resistance
More informationGasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF
GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-00-VEF 7.03 Max. operating pressure 30 mbar Compact design High flow values Low weight Low power consumption
More informationType 4708 Supply Pressure Regulator
Type 478 Pressure Regulator Application pressure regulator used to provide pneumatic measuring and control equipment with a constant air supply Set point ranges. to.6 bar ( to 4 psi) or. to 6 bar (8 to
More informationEx-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification ATEX, IECEx, EAC
www.atos.com Table -2/E Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification TEX, IEEx, E valve body spool ex-proof solenoid ex-proof inductive
More informationE28/Q28 Safety Exhaust Valve Externally Monitored
E8/Q8 Safety Exhaust Valve Externally Monitored ulletin 9EM4 the total systems approach to air preparation Features Externally Monitored Safety Exhaust Valve Function When applications demand a safe environment
More informationElectropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765
Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765 Application Single-acting positioner for attachment to pneumatic control valves. Supplied with either an electric input signal from
More informationTECHNICAL CHARACTERSTICS
and solenoid valves spool version GM - GL series Type of valves with dorsal consumption: GM-...series with integrated connections GL-...series without connections TECHNICAL CHARACTERSTICS Ambient temperature:
More informationPneumatic Function Fittings Metric & Inch
Metric & nch Sensor Fitting Very compact units asy tube insertion for rapid assembly of pneumatic circuits Positive tube anchorage Simpler pneumatic systems liminates need for electrical reed switches
More informationFilter pressure regulator, Series AS3-FRE G 3/8 - G 1/2 filter porosity: 5 µm lockable for padlocks with pressure gauge suitable for ATEX
Filter regulator, Series AS3-FRE G 3/8 - G 1/2 filter porosity: 5 µm lockable for padlocks with gauge suitable for ATEX 1 00119372 Version Parts Mounting orientation Working min./max. Medium Medium temperature
More informationSafety and Shut-off Block SAF/DSV
Safety and Shut-off Block SAF/DSV 1.1.1 Key to the circuit diagram Circuit diagram The HYDAC safety and shut-off block is used to shut off and discharge hydraulic accumulators or consumers. It complies
More informationVALVES ISO 5599/1, SERIES IPV-ISV
VALVES ISO 99/1, SERIES IPV-ISV The assembly surface dimensions of ISO1 and ISO2 valves are to ISO99-1. They are available in the -way versions with 2 and 3 positions and with pneumatic or solenoid actuation.
More informationOld documentation - Only for your information! Product is not available anymore!
Double solenoid valve Regulator and safety combination Infinitely variable floating operation DM-EF 07-7. Printed in Germany Rösler Druck Edition 0.0 Nr. 9 Flanges, pressure switches, line sockets, pulse
More informationDual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series
Dual Modular Safety Shutoff Valves with Two-stage operation DMV-ZRD/602 Series DMV-ZRDLE/602 Series Two normally closed automatic shutoff valves in one housing; each with the following approvals. UL Recognized
More informationProportional pressure regulators VPPE
Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/
More informationDirect Operated Precision Regulator Modular Style. Standard Specifications
1 Direct Operated Precision Regulator Modular Style Series P3 Courtesy of Steven Engineering, Inc.-23 Ryan Way, South San Francisco, CA 948-637-Main Office: (65) 588-92-Outside Local Area: (8) 258-92-www.stevenengineering.com
More informationCompact differential pressure switch Flameproof enclosure Ex d Models DE, DEC
Mechatronic pressure measurement Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC WIKA data sheet PV 35.41 Process Compact Series Applications Differential pressure monitoring
More informationSpool compact valves pilot and solenoid actuated G 1/8 - G 1/4
Spool compact valves pilot and solenoid actuated G 1/8 - G 1/4 DESCRIPTION Valves series "MEK", in the 5/ and pneumatic functions, have been realized with compact overall dimensions yet assuring high flow.
More information2/2-Way Solenoid Control Valve
2/2-Way Solenoid Control Valve Excellent range (1:200) Very good response Compact valve design Orifice sizes 0.05... 2.0 mm Port connection 1/8 or sub-base Type 2871 can be combined with Type 8605 Digital
More informationPanel-mounted valves Series T, Ø 22.5 mm
Series T, Basic valve 3/2-way, M5 (10/32 UNF) M 5 and G 1/8 2.122 Basic valve 3/2-way, M5 (10/32 UNF) M 5 and G 1/8 2.122 Push button 18-T-23-011 2.126 Mushroom 18-T-23-012 2.126 2-position switch 18-T-23-013
More informationProp. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08
Prop. -Way Pressure-Reducing Cart., Size / SAE 8 Q max = 1 l/min (4 gpm), p max = bar (6 psi) Direct acting, electrically operated 1 Description proportional -way pressure-reducing cartridges are size
More informationPressure regulators Manually operated Fine setting valves. Brochure
Pressure regulators Manually operated s Brochure Pressure regulators Manually operated s Qn = 9 l/min Actuating element: Push button Internal thread Poppet valve Qn = 9 l/min Actuating element: Push button
More informationKM/ Stainless steel air bellows Single acting Ø 220 to 400 mm
KM/ Stainless steel air bellows Single acting Ø to mm Stainless steel end plates Frictionless operation No maintenance or lubrication Ideal for short stroke, high-force applications High isolation level
More informationII 2G EEx ia IIC T6. Ignition protection class
ATEX General information According to 94/9/EC, a device that is to be used in an environment at risk of explosion may only be brought into the market if it satisfies the standards specified in the norm.
More informationDescription Pressure range Connection thread Device Page
Pressure Regulator Pressure range onnection thread Device Page max. 22 l/min miniature -850 0 mbar 1 8 NPT V800.02 max. 22 l/min miniature -850 0 mbar 10-32 and flange V900.02 max. 0 l/min precise -1 +0,.4
More informationFILTER, REGULATOR AND FILTER/REGULATOR Stainless Steel 316L Compact 1/4, High Flow 1/4-1/2
FILTER, REGULATOR AND FILTER/REGULATOR Stainless Steel L Compact /, High Flow / - / Air service equipment Series FEATURES Stainless Steel filter, regulator and filter regulator intended for corrosive environment
More informationDual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series
Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure DMV-D/624L Series DMV-DLE/624L Series Two normally closed automatic shutoff valves in one housing. Valve 2 (V2) incorporates proof
More informationComponents for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.
Components preparation and pressure adjustment ABP Overview ABP is a component that enables boosting by s only up to twice primary pressure (.0MPa max.) in combination with using air tank but not using
More informationAir service units series Y G1/4 to G1
Air service units series Y Series FY Filter, 12.071 Series RY+ RYP Pressure regulator, 12.076 Series FRY Filter/regulator, 12.080 Series OY Lubricator, 12.083 Series FROY Filter, Regulator, Lubricator
More informationSafety and Shut-off Block SAF/DSV
Safety and Shut-off Block SAF/DSV 1. DESCRIPTION 1.1. GENERAL The HYDAC safety and shut-off block is used to shut off and discharge hydraulic accumulators. It complies with the relevant safety standards
More informationFloat Operated Level Controllers
CONTENTS Float Operated Level Controllers IM0015 Nov. 2014 PAGE Introduction 1 Scope 1 Description 1 Specification 1 Control Installation 2 INTRODUCTION Side Mount Back Mount Prior to installing, the instructions
More informationPrecision pressure regulators LRP/LRPS
Precision pressure regulators LRP/LRPS q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement
More information250 (9.84) 170 (6.69) 225 (8.85) 75 (2.95) 300 (11.81)
Air bellows, single acting Ø... / inch Suitable for applications on rail vehicels Almost frictionless operation No maintenance or lubrication Weather/corrosion resistant metal parts Approvals for fire
More informationHAZARDOUS AREA DIFFERENTIAL CLOGGING INDICATOR DEH SERIES
HAZARDOUS AREA DIFFERENTIAL CLOGGING INDICATOR PASSION TO PERFORM Filter elements are efficient only if their dirt holding capacity is fully exploited. This is achieved by using filter housings equipped
More informationFlow and check valves Non-return valves Series NR02. Brochure
Flow and check valves Non-return valves Series NR0 Brochure Flow and check valves Non-return valves Series NR0 Qn = 300-680 l/min thread-in 3 Qn = 70-800 l/min thread-in 5 Qn = 480-5800 l/min installing
More informationSO 9001 I ACCESSORIES
ISO 9001 ESSORIES ESSORIES INDEX Page In-Line Mounted Flow ontrol Valves 3 In-Line Mounted heck Valves 3 Quick Exhaust, heck and Shuttle Valves In-Line Ported Lockout Valves 5 Mufflers 6 Fittings 7-9 2
More informationHeavy Metal Stainless Steel Valves
2.10 page 187 2.10 Heavy Metal Stainless Steel Valves Selected models are available for explosion hazardous environment. They are ATEX-Ex certified. For detailed information refer to chapter 2.12. 316
More information1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type
Flow Control Valve Series LVM.. high flow rates (8 l/min) flow rates are unaffected by temperature change or when the higher load pressure alternates between the outlet ports proportional flow-sharing
More informationPilot Check Valve: Metal Body Type
INFORMATION Pilot Check Valve: Metal Body Type The use of a metal body improves strength and environmental resistance. Temporary intermediate stops are possible. *1 *1 Precise intermediate stops are not
More informationSITRANS P measuring instruments for pressure
SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and
More informationType 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation
Type 0404 / 5404 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions
More informationMounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type
Type 4708 Supply Pressure Regulators Translation of original instructions Type 4708-53 Type 4708-64 Type 4708-12 Mounting and Operating Instructions Edition March 2018 Note on these mounting and operating
More informationMECAIR CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS PRODUCT LEAFLET
CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS GENERAL CHARACTERISTICS CONSTRUCTION FEATURES ENCLOSURE OPERATING TEMPERATURE 20 C/+60 C COVER Diecast aluminium (anodised) WEIGHT CSN 5 3.5 kg CSN 8 5 kg CSN
More informationSeries 4 Cv= Air-Pilot operated valves. 3-way/2-position, 5-way/2-position, 5-way/3-position
3 Cv =.73-2.00 Series 4 Cv=.73-2.00 Air-Pilot operated valves Series 4: 1/8,, 3-way/2-position; 5-way/2-position; 5-way/3-position 1/2 5-way/2-position The pneumatically operated,3-way/2-position, 5-way/2-position
More informationDual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure DMV-ZRD/612 Series DMV-ZRDLE/612 Series
Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure DMV-ZRD/612 Series DMV-ZRDLE/612 Series Two normally closed automatic shutoff valves in one housing. Valve 1 (V1) incorporates
More informationDual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series
Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure DMV-D/624L Series DMV-DLE/624L Series Two normally closed automatic shutoff valves in one housing. Valve 2 (V2) incorporates proof
More informationBW0500AO. ByWire Elements BW0500AO Element 4/3 with side ports IBW0500 Interface
ywire Elements Element 4/3 with side ports IW5 Interface efore use, carefully read the GENERL INSTRUCTIONS FOR USE OF DIRECTIONL CONTROL VLVES 398SW5EN - 5--8 Technical data Nominal flow 5 l/min 3. US
More informationRegulator: Modular Type with Back flow Mechanism. AR30K to 60K. Body size. Port size 1/4 3/8 1/2 3/4 AR40 AR50 3/4 1/2
Regulator: Modular Type with ack flow Mechanism R3 to 6 How to Order Regulator with a built-in mechanism that ensures a quick release of the outlet air pressure (built-in check valve with back flow mechanism).
More informationAir service units series K G1/8, G1/4
Air service units series K Series FK Filter 12.011 Series RK Pressure regulator 12.012 Series FRK Filter/regulator 12.013 Series OK Lubricator 12.014 Series FROK Two piece air service unit 12.015 Series
More information