PRODUCTS CATALOGUE 2017 / Torino - Strada Settimo 388/15 Tel (+39) /43 Fax (+39)

Size: px
Start display at page:

Download "PRODUCTS CATALOGUE 2017 / Torino - Strada Settimo 388/15 Tel (+39) /43 Fax (+39)"

Transcription

1 PRODUCTS CATALOGUE 2017 / Torino - Strada Settimo 388/15 Tel (+39) /43 Fax (+39) info@ebarbero.com

2 CATALOGO INDEX PRODOTTI 2017 / 2018 Pumps for LPG: - BGA: self-priming centrifugal pump for LPG - BGL: self-priming centrifugal pump for LPG - BGD: new self-priming pump for LPG Accessories for LPG: - VSG 20: By-pass valve - VFO 50: non-return valve Series SBF: pumping units with submersible motor pump for fuel delivery Series T / TFL: gear pumps for oils Special order pumps pag. 2 pag. 7 pag. 11 pag. 16 pag. 19 pag. 22 pag. 28 pag. 34 1

3 BGA SELF-PRIMING CENTRIFUGAL PUMPS FOR LPG An innovative design to ensure: Top safety Easy installation Easy maintenance

4 BGA SELF-PRIMING CENTRIFUGAL PUMPS FOR LPG Exclusive features of BGA series: Casings and elements with O-Ring seal for easy maintenance; Safety system against product s spil; Serie TFL ATEX certified: II 2G T4 Composed by several self-priming stages with a first centrifugal stage mounted at the suction end, BGA pumps perform an extremely low NPSH required valour and are suitable to handle liquids with entrained gases and especially for liquefied gases such as LPG.

5 BGA SELF-PRIMING CENTRIFUGAL PUMPS FOR LPG Construction and materials: Pump casing: Cast iron Centrifugal impeller: Special reinforced resin Self-priming impellers: Leaded brass Shaft: AISI 420 stainless steel Bearing: - Drive end: Ball bearing - Suction side: Graphite bushing Sealing: Double mechanical seal in oil bath Coupling: Aluminium alloy bell-housing and drive coupling for B5 motors Performance data at 1450 rpm Data refer to water - Tolerance 5% Compare BGA performance with those of the competitors! BGA pump grants higher pressure in all delivery range: from 10 to 20% more.

6 BGA SELF-PRIMING CENTRIFUGAL PUMPS FOR LPG Flanges dimensions according to UNI PN 40

7 BGA SELF-PRIMING CENTRIFUGAL PUMPS FOR LPG Anti-spillage device 1. Oil reservoir 2. Plug with vent valve 3. Gauge 4. Pressure switch BGA pumps are equipped with a sealing system with double tandem mechanical seals with intermediate oil chamber, connected to an oil reservoir. The plug of the reservoir includes a special vent valve. In normal conditions, the reservoir is always at atmospheric pressure. In case of leak from the internal mechanical seal, the flow of liquid makes the vent valve to close putting under pressure the reservoir. This way, by means of a gauge and a pressure switch we can have an immediate detection of the problem without spillage of product. Pump can continue to work for a while giving the time to schedule the maintenance in order to restore initial safety conditions. Note: Gauge and pressure switch are excluded from supply.

8 BGL SELF-PRIMING CENTRIFUGAL PUMPS FOR LPG An innovative design to ensure: Top safety Top performances Easy maintenance

9 BGL SELF-PRIMING CENTRIFUGAL PUMPS FOR LPG Exclusive features of BGL series: Composed by several self-priming stages with a first centrifugal stage mounted at the suction end, BGL pumps perform an extremely low NPSH required valour and are suitable to handle liquids with entrained gases and especially for liquefied gases such as LPG. Casings and elements with O-Ring gaskets for perfect sealing and easy maintenance.

10 BGL SELF-PRIMING CENTRIFUGAL PUMPS FOR LPG Construction and materials: Pump casing: Cast iron Centrifugal impeller: Special reinforced resin Self-priming impellers: Leaded brass Shaft: AISI 420 stainless steel Bearing - Drive end: Ball bearing - Suction side: Graphite bushing Sealing: Mechanical seal Performance data at 1450 rpm: Data refer to water - Tolerance 5% NPSH (r) = Minimum positive head required for liquids in boiling conditions. Compare BGL performances with those of the competitors! BGL pump ensure more pressure in all delivery range: from 10 to 20% higher.

11 BGL SELF-PRIMING CENTRIFUGAL PUMPS FOR LPG Flanges dimensions according to UNI PN 40

12 BGD NEW SELF-PRIMING PUMPS FOR LPG PATENTED An innovative design to guarantee: Top performance Top safety Easy maintenance

13 BGD NEW SELF-PRIMING PUMPS FOR LPG Exclusive features of BGD series: This pump is an absolute breakthrough in the field of self-priming LPG pumps. It is a multi-stage pump that operates according to a new principle. It consists of a set of side channel type stages with star impeller to which a special volumetric self-priming stage is connected on the suction side. The result is a pump with a much higher suction capacity than any other existing pump. In normal conditions, priming time is reduced by one third, thus eliminating downtimes in product delivery. In particular conditions, such as: > Crityical systems because of high suction gradient or with vertical tank; > Systems affected by periodic pumping problems due to climate or the product pumped. In all these cases, the BGD pump solves the problem, guaranteeing regular functioning. The highly-efficient volumetric self-priming stage guarantees fast, trouble-free suction of the gaseous phase of the product which is always present in the pipes at any start of the pump. So the pump does not require any external degassing device, thereby simplifying the system and reducing the related costs.

14 BGD NEW SELF-PRIMING PUMPS FOR LPG With regard to safety, the pump is fitted with an anti-spillage system that makes it possible to monitor any leak from the mechanical seal without product spillage, thereby eliminating one of the major risk of LPG plants. Another unique feature of this pump is that each element is sealed using O-Ring gaskets where other pumps adopt flat gaskets and sealing glue. The O-Ring guarantees perfect seal and, above all, fast, easy pump disassembly and re-assembly. This close coupled pump is fitted with bell housing and drive coupling which guarantees simple, safe connection to the electric motor. The motor pump is vibration-free and very silent with a sound level of less than 70 db. The pump has steel made, slip-on flanges DN 32 PN 40. ATEX Certification Ex II 2G T4

15 BGD NEW SELF-PRIMING PUMPS FOR LPG Performance data at 1450 rpm: Liquid LPG Specific Density 0,55 Kg/l (Tolerance +/- 2,5%) Flanges dimensions according to UNI PN 40

16 BGD NEW SELF-PRIMING PUMPS FOR LPG Anti-spillage device 1. Oil reservoir 2. Plug with vent valve 3. Gauge 4. Pressure switch BGD pumps are equipped with a sealing system with double tandem mechanical seals with intermediate oil chamber, connected to an oil reservoir. The plug of the reservoir includes a special vent valve. In normal conditions, the reservoir is always at atmospheric pressure. In case of leak from the internal mechanical seal, the flow of liquid makes the vent valve to close putting under pressure the reservoir. This way, by means of a gauge and a pressure switch we can have an immediate detection of the problem without spillage of product. Pump can continue to work for a while giving the time to schedule the maintenance in order to restore initial safety conditions. Note: Gauge and pressure switch are excluded from supply.

17 VSG 20 BY-PASS VALVE FOR LPG Certification ATEX II 2G T4

18 VSG 20 BY-PASS VALVE FOR LPG Exclusive features of VSG 20 valve: The by-pass valve VSG 20 type is a multi purpose valve designed for use in LPG pumping systems. Installed on a LPG pump, the valve performs a double function: a) starting the pump, the valve enables the vapours to leak out from the pumping system; b) when the pump primes, the valve limits the maximum pressure of the pump. The valve has steel made flanges, sliding type, DN 20 PN 40 Operating limits: Temperature: -20 C / +60 C Maximun pressure: bar 40 Differential pressure range: min 10 / max 20 bar Max flow rate: 100 l/min

19 VSG 20 BY-PASS VALVE FOR LPG Valve VSG 20 construction: Sliding Flanges UNI DN 20 PN 40

20 VFO 50 NON-RETURN VALVE FOR LPG Certification ATEX II 2G T4

21 VFO 50 NON-RETURN VALVE FOR LPG Exclusive features of VFO 50 valve: The VFO 50 non-return valve was designed for installation on BGL series pumps in LPG delivery systems. The valve is used to prevent the return of liquid from the suction pipe, ensuring that the pump is always primed. The valve has DN50 PN 40 coaxial connections. Operating limits: Temperature: - 20 C / + 60 C Maximum pressure: bar 40

22 VFO 50 NON-RETURN VALVE FOR LPG Valve VFO 50 construction: Flanges UNI DN 50 - PN 40

23 series SBF PUMPING UNITS with submersible Motor Pumps for fuel delivery Indispensable in large service stations to take advantage of the delivery capacity of Multidispensers.

24 series SBF PUMPING UNITS with submersible Motor Pumps for fuel delivery Submersible Motor Pumps: Submersible motor pumps for fluel distribution system have been used for many years and their success is due to the advantages they undoubtedly offer compared to traditional systems. They represent the most rational solution to supply fuel dispenser and are indispensable in big, modern Service Stations. The Series SB/F Pumping Units are the result of a refined and innovative project that has led to significant product development and establishes a new standard in the field of submersible motor pumps for fuel. Detailed tests regarding performance and characteristics of the Motor Pump, the Discharge Head and the relative Leak Detector Valve VRF 4, confirm that the Series SB/F Pumping Units are unique in that each individual component is of the highest standard and, in some case, these are decidedly innovative.

25 series SBF PUMPING UNITS with submersible Motor Pumps for fuel delivery Exclusive features of submersible Motor Pumps: The Series SB/F is available in a range of three different capacities and performance levels, to meet the demands of modern Service Stations and fully exploit the delivery capacity of the new Multi-dispenser nozzles with vapour recovery. A robust stainless steel jacket houses the motor pump. The three-phase electric motor guarantees an excellent quality level and complies with the strictest safety regulations: Temperature T6 classification explosion-proof certificate (maximum surface temperature 85 ) Motor pump grounding conductor connected directly to the motor casing Thermal protector to stop the motor in case of overhating. Automatic restore when the temperature level falls. Sintered bronze depuration filter for motor bearing cooling liquid. THE RANGE

26 series SBF PUMPING UNITS with submersible Motor Pumps for fuel delivery Discharge head: The design of the head is strealine and rational, featuring unique constructive characteristics: ll caps have O-ring seals. The internal parts can be reached easily and quickly, seal is always perfect and maintenance times are drastically reduced. A large basket strainer protects head parts and all components situated downstream of the pump against impurities. This is obviously of great advantage to overall system management, where liquid impurities are one of the main causes of problems. The outlet is directed in a downward position and is equipped with a flange with O-ring seal. This system enables simple connection to underground piping, even in confined spaces, and guarantees problem-free seal. The equipment also copries a vent screw for a manual pressure relief, extremely useful to bleed to zero head and line pressure, preventing products during maintenance operations.

27 series SBF PUMPING UNITS with submersible Motor Pumps for fuel delivery Leak detector valve VRF 4: This is a piston valve designed to perform various functions, the most important of which is to signal any leaks from the delivery pipes. As regards this function, the valve is characterized by the test execution time, (less tha 5 sec) and the large internal capacity, capable of compensating the product's thermal volume changes. The valve also has a built in Venturi System in the cap together with the relative suction and discharge connections. The Venturi enables the valve to execute siphon priming in order to empty two or more tanks using the same pump. When the pump stops, the valve adjusts the head pressure for the Unit, limiting it approximately 0,7 bar, by means of the Venturi discharge. The valve also performs an effective air bleeding function. Each time the pump is activated, any air present in the discharge head is bled within a few seconds by means of the Venturi System discharge, thus ensuring delivery of a degassed product. Diagrammatic section with current flow

28 series SBF PUMPING UNITS 3 with submersible Motor Pumps for fuel delivery O-ring seal cup 2. Check valve 3. O-ring seal cup 4. Strainer 5. 4 wire cable: line, ground 6. Vent screw 7. Leak detector Operating curves:

29 series T / TFL GEAR PUMPS FOR OILS A rational design that ensures: Robustness Reliability No servicing

30 series T / TFL GEAR PUMPS FOR OILS Exclusive features of gear pumps: T series gear pumps are positive-displacement self-priming pumps, suitable for conveying any type of clean and chemically non-aggressive liquid, as long as it has some lubricating properties. By choosing a suitable rotation speed, they can also be used for conveying highly viscous fluids. They have helical gears to ensure low noise and pulsation levels. Rational design and generous dimensioning of the parts make these pumps especially robust, reliable and free of servicing problems. Serie T Foot-mounted construction with bypass Serie T Foot-mounted construction with cover Serie TFL Close-coupled construction

31 series T / TFL GEAR PUMPS FOR OILS Rotation and flow direction: The arrow on the pump indicates both direction of rotation and flow. Looking the drive-shaft, direction of rotation is clockwise and flow goes from left (suction) to right (discharge). Anticlockwise rotation can be supplied on request. Relief-valve: To avoid dangerous over-pressures, pump can be equipped with an integral relief-valve of inside-recycling type or externalrelease type. The integral relief-valve must work occasionally and for short periods; when continuous pressure regulation is required, another relief-valve has to be installed on the delivery pipe.

32 series T / TFL GEAR PUMPS FOR OILS Nominal capacity Lt / min: type TFL type T

33 series T / TFL GEAR PUMPS FOR OILS Construction materials and limits:

34 series T / TFL GEAR PUMPS FOR OILS Performance data: type TFL type T Capacity data refer to oil 30 cst viscosity and are subject to 3% tolerance. Absorbed power data are valid up to 200 cst, beyond this value of viscosity they have to be properly increased. Installed power has to be at least 20% more then absorbed power.

35 SPECIAL-ORDER CATALOGO PUMPS PRODOTTI 2017 / 2018 A wide range of horizontal and vertical SELF-PRIMING and IMPELLER pumps can be produced upon request, according to the client s specific requirements. All pumps are constructed individually to order with the aim of meeting customer needs, and everything is perfectly traceable from the quotation, through implementation and up to testing.

36 10156 Torino - Strada Settimo 388/15 Tel (+39) /43 Fax (+39) info@ebarbero.com

Liquid ring compressors

Liquid ring compressors Liquid ring compressors KPH 85220, KPH 85227 Compression pressures: Suction volume flow: 2 to 7 bar 940 to 1450 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring compressors are displacement compressors

More information

Liquid ring compressor

Liquid ring compressor Liquid ring compressor KLH 47005, KLH 47105 Compression pressures: Suction volume flow: 2 to 11 bar 56 to 65 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring compressors are displacement compressors of

More information

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10 / ED VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES OPERATING PRINCIPLE The VPPL are variable displacement axial-piston pumps with variable swash plate, suitable for applications

More information

SIHI LPH-X - Liquid Ring Compressors

SIHI LPH-X - Liquid Ring Compressors - Liquid Ring Compressors LPH 50523 LPH 60527 Pressure range: Suction volume range: 0.2 to 1.5 bar 260 to 780 m³/h CONSTRUCTION Sterling SIHI liquid ring compressors are displacement compressors with a

More information

Liquid ring vacuum pumps single-stage

Liquid ring vacuum pumps single-stage Liquid ring vacuum pumps single-stage LPH 40106, LPH 40411, LPH 40516 Pressure range: Suction volume flow: 150 to 1013 mbar 50 to 270 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring vacuum pumps are displacement

More information

Dean Pump Self-Priming Chemical Process Pumps

Dean Pump Self-Priming Chemical Process Pumps Bulletin C 1.2.34.7 Dean Pump Self-Priming Chemical Process Pumps php Series HEAD CAPACITY RANGE CHARTS php Self Primer - 2 Pole 3500 RPM 500 CAPACITY M 3 /HR 2900 RPM 50 HERTZ 25 50 75 125 150 400 TOTAL

More information

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

Displacement 12, , Maximum flow rate (at 1450 rpm) bar. 00/07 ED PVD VARIABLE DISPLACEMENT VANE PUMPS SERIES 0 OPERATING PRINCIPLE The PVD pumps are variable displacement vane pumps with a mechanical type of pressure compensator. They allow instantaneous adjustment

More information

Liquid ring vacuum pumps in compact design

Liquid ring vacuum pumps in compact design Liquid ring vacuum pumps in compact design, Pressure range: Suction volume flow: 33 to 113 mbar 3 to 58 m³/h CONSTRUCTION TYPE SIHI liquid ring vacuum pumps are displacement pumps of uncomplicated and

More information

50Hz. water solutions. O SerieS DGO DRO

50Hz. water solutions. O SerieS DGO DRO Hz water solutions O SerieS DGO DRO D a t a b o o k l e t EN water solutions O SerieS DGO DRO Hz D a t a b o o k l e t O SERIES O Series General characteristics AISI stainless steel lifting and carrying

More information

Liquid ring vacuum pumps in compact design

Liquid ring vacuum pumps in compact design Liquid ring vacuum pumps in compact design LEM 25, LEM 5 Pressure range: Suction volume flow: 33 to 113 mbar 4 to 6 m³/h CONSTRUCTION SIHI liquid ring vacuum pumps are displacement pumps of uncomplicated

More information

TECHNOLOGIES. M Series. Positive return metering pumps [API675]

TECHNOLOGIES. M Series. Positive return metering pumps [API675] M Series Positive return metering pumps [API675] Hydraulic double diaphragm metering pump in AISI 316L stainless steel A line of plunger and hydraulic double diaphragm metering pumps designed according

More information

Design. Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing. Working Principle

Design. Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing. Working Principle SB Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing A family of API liquid ring compressors has been developed and has been in the market for nearly a decade, they are specifically made

More information

Serie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E

Serie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E Serie ECO T Threaded end back flow preventer with controllable reduced pressure zone BRANDONI made in E U R O P E Application fields WATER FIRE FIGHTING DRINKING WATER 74 www.brandoni.it Serie ECO T The

More information

GRAPHIC DIVISION. 3D drawings available at

GRAPHIC DIVISION. 3D drawings available at GRAPHIC DIVISION GRAPHIC DIVISION PRODUCT DESCRIPTION PAG..01 TABLES FOR PNEUMATIC PUMPS SELECTION PAG..02 SMALL PNEUMATIC SUCTION PUMPS ART. PA 3 and PA 7 PAG..03 SMALL PNEUMATIC SUCTION PUMPS ART. PA,

More information

Liquid ring vacuum pumps in compact design

Liquid ring vacuum pumps in compact design Liquid ring vacuum pumps in compact design LEM 26, LEM 51 Pressure range: Suction volume flow: 33 to 113 mbar 3 to 58 m³/h CONSTRUCTION TYPE SIHI liquid ring vacuum pumps are displacement pumps of uncomplicated

More information

Serie ECO 3F. Flanged back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection

Serie ECO 3F. Flanged back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection Flanged back flow preventer with controllable reduced pressure zone made in Application fields WATER FIRE FIGHTING DRINKING WATER 64 www.brandoni.it The ECO 3F flanged backflow preventers, which have a

More information

OWNER S TECHNICAL MANUAL

OWNER S TECHNICAL MANUAL EL SERIES OWNER S TECHNICAL MANUAL DP7002 1 Air Operated Diaphragm Pump Description The DP7002 1 air operated diaphragm pump is the ideal device for the pumping, transfer and dispensing of chemical liquids,

More information

Flanged pressure reducer/stabilizer VRCD

Flanged pressure reducer/stabilizer VRCD Flanged pressure reducer/stabilizer VRCD 2 This unit reduces and stabilizes the upstream pressure by operating on its load losses with a constant downstream pressure irrespective of the rate of flow value.

More information

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28 Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) and balanced Type 2422 Valve Type 42-24 Type 42-28 Application Differential pressure regulators

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S Page 1 of 13 1. DESCRIPTION The Viking 6 Model G-6000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler

More information

Liquid ring compressors

Liquid ring compressors Liquid ring compressors KPH 95652 Compression pressures: 6 to 12 bar(g) Suction volume flow: 2960 to 3600 m³/h 78 to 174 psig 1742 to 2119 cfm DESIGN TYPE SIHI liquid ring compressors are displacement

More information

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13 Page 1 of 13 1. Description The Viking 2 Model G-2000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler

More information

Air Operated Hydraulic Pumping Systems to 50,000 psi

Air Operated Hydraulic Pumping Systems to 50,000 psi High Pressure Equipment Air Operated Hydraulic Pumping Systems to 50,000 psi PS-10: 10,000 psi PS-20: 20,000 psi PS-30: 30,000 psi PS-40: 40,000 psi PS-50: 50,000 psi PS-90: 90,000 psi High Pressure air

More information

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY Page 1 of 13 1. DESCRIPTION The Viking 3 Model G-3000 Dry Valve Riser Assembly is equipped with a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry

More information

Variable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design

Variable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design Brueninghaus Hydromatik Series 1, for open circuits Axial piston - swashplate design, Back to back - design RE 93100/02.97 Sizes 60...260 Nominal Pressure up to 350 bar Peak Pressure up to 400 bar Preliminary

More information

Level switches Series LD Vibrating fork level switch for liquids and solids

Level switches Series LD Vibrating fork level switch for liquids and solids Level switches Series LD Vibrating fork level switch for liquids and solids Robust and compact Suitable for liquids (model LD61) and solids (model LD60) No moving parts, low maintenance Corrosion resistant

More information

PROCESS ROTATING EQUIPMENT (CENTRIFUGAL PUMPS )

PROCESS ROTATING EQUIPMENT (CENTRIFUGAL PUMPS ) PROCESS ROTATING EQUIPMENT ( ) Slide No: ١ Pumps can be divided into two main groups: Displacement pumps Dynamic pumps Slide No: ٢ Slide No: ٣ Slide No: ٤ Slide No: ٥ BASIC CENTRIFUGAL PUMP PARTS Casing

More information

Level switches Series LD Vibrating fork level switch for liquids and solids

Level switches Series LD Vibrating fork level switch for liquids and solids Level switches Series LD Vibrating fork level switch for liquids and solids Robust and compact Suitable for liquids (model LD61) and solids (model LD60) No moving parts, low maintenance Corrosion resistant

More information

TECHNICAL DATA. Q= Cv S

TECHNICAL DATA. Q= Cv S Page 1 of 13 1. DESCRIPTION The Viking 4 inch Model G-4000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry

More information

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ and SE Nominal flow rate up to 6 l/min Description pplication For operation in units with hydrostatic drives, when the return flow

More information

TRZ 03-K Volumeter. Proven Technology. Superior Performance. TRZ 03-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering.

TRZ 03-K Volumeter. Proven Technology. Superior Performance. TRZ 03-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering. TRZ 0-K Volumeter TRZ 0-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering. TRZ 0-K Turbine Gas Flowmeter continues the tradition of Honeywell s field-proven turbine meter technology, delivering

More information

6301 TYPE CAST IRON SAFETY VALVES

6301 TYPE CAST IRON SAFETY VALVES Pressure (bar) 6301 TYPE CAST IRON SAFETY VALVES FEATURES The 6301 type safety valve is a device designed to protect installations against possible overpressure. It operates automatically and closes when

More information

Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series

Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series Main features Designed for automatic filling of sealed heating systems and for protection of the water mains from risk of contamination.

More information

DEWATERING PUMP SOLUTIONS. Pneumatic pumps

DEWATERING PUMP SOLUTIONS. Pneumatic pumps DEWATERING PUMP SOLUTIONS Pneumatic pumps PUMP UP YOUR BUSINESS A pneumatic pump is a great choice when failure is not an option. They re easy to use, safe and can handle almost anything you throw at them.

More information

Page - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 ITEM QUANTITY FOR MODEL 302

Page - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 ITEM QUANTITY FOR MODEL 302 CONTENTS. Page - SPECIFICATIONS 200 SPECIFICATION 200 SELECTION CHART PFC 201 SELECTION CHART 202 TYPE KEY AND CURVE SPECIFICATIONS 203 PERFORMANCE CURVE 2 204 PERFORMANCE CURVE 3 205 PERFORMANCE CURVE

More information

VALFONTA INSTRUCTIONS: OPERATION AND INSTALLATION PRESSURE REDUCING VALVE MODEL PRV44

VALFONTA INSTRUCTIONS: OPERATION AND INSTALLATION PRESSURE REDUCING VALVE MODEL PRV44 INSTRUCTIONS: OPERATION AND INSTALLATION PRESSURE REDUCING VALVE MODEL PRV44 Pressure Reducing Valve PRV44 - Operation and Installation - 1 - manual PRV44-16-ENG JULY 2016 INDEX PAGE 1 IDENTIFICATION PLATE

More information

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE ATEX CHEMISTRY DIAPHRAGM PUMPS. ATEX VARIO CHEMISTRY DIAPHRAGM PUMPS. Chemistry diaphragm pumps, vacuum systems and gauges for use in

More information

OFFICINE OROBICHE S.p.A. 1/9

OFFICINE OROBICHE S.p.A. 1/9 OFFICINE OROBICHE S.p.A. 1/9 INSTRUCTIONS MANUAL FOR LEVEL SWITCHES SERIES 7000 mod. 7250 AND 7400 Electric 1. INSTRUMENT DESCRIPTION Series 7000 level switches have been designed for external lateral

More information

A new concept in the storage of liquefied chemical and petrochemical gases Zero leakage Zero fugitive emissions

A new concept in the storage of liquefied chemical and petrochemical gases Zero leakage Zero fugitive emissions A new concept in the storage of liquefied chemical and petrochemical gases Zero leakage Zero fugitive emissions Introduction Industries involved in the handling of dangerous fluids have to answer increasing

More information

Pressure reducing valves Index

Pressure reducing valves Index Index General information page Introduction 506 General introduction 507 for a steam plant 509 Product information BSP thread page Brass 510 ; BSP female thread 511 ; BSP male thread 513 Stainless steel

More information

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1 Dry 131h 1. DESCRIPTION The Viking Model G-1 Maintenance Air Compressor is an electric motor-driven, aircooled, single-stage, oil-less compressor. The unit is equipped with a check valve and provides a

More information

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER SUPPLIMENT TO eom IMPORTANT READ THIS MANUAL BEFORE PRODUCT INSTALLATION, OPERATION, INSPECTION & MAINTENANCE Tougher and more rigid guidelines are being established

More information

756 Safety Relief Valves

756 Safety Relief Valves 756 S a fe t y R e l i e f Va l ve s INTRODUCTION 756 Safety Relief Valves The effects of exceeding safe pressure levels in an unprotected pressure vessel or system, can have catastrophic effects on both

More information

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out PumpAgents.com - Click here for Pricing/Ordering Model 31670-Series Dual Max 7.5 GPM (28 LPM) AUTOMATIC TWO STAGE WATER SYSTEM WITH ACCUMULATOR TANK AND PUMPGARD STRAINER IDEAL FOR PLEASURE AND COMMERCIAL

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 348a 1. Description Viking supervised Surefire Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated Viking G-6000P Valve comes complete

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 333a 1. Description Viking supervised Surefire Preaction Systems Utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated Viking G-3000P Valve comes complete

More information

Operating Instructions Models and Hydrostatic Test Pumps

Operating Instructions Models and Hydrostatic Test Pumps Operating Instructions Models 33100 and 33101 Hydrostatic Test Pumps 33100 DIMENSIONS: WEIGHT: PUMP: MOTOR: CONTROL: GAUGE: DISCHARGE HOSE: 16 (40cm) L x 22 (55cm) W x 18 (45cm) H 87 lbs., 39.5 kg Triplex

More information

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS THE COMPANY ITAP SpA, founded in Lumezzane (Brescia) in 1972, is currently one of the leading production companies in Italy of valves, fittings and

More information

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ / - SE and SE Nominal flow rate up to 6 l/min / 8. gpm Description pplication For operation in units with hydrostatic drives, when

More information

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS ITAP SpA, founded in Lumezzane (Brescia) in 1972, is currently one of the leading production companies in Italy of valves, fittings and distribution

More information

DEEP WELL SUBMERSIBLE PUMPS. An ISO 9001 & Company

DEEP WELL SUBMERSIBLE PUMPS. An ISO 9001 & Company C.R.I. PUMPS DEEP WELL SUBMERSIBLE PUMPS EVERGREEN SERIES - 5Hz An ISO 91 & 141 Company Submersible Pumps C.R.I. Submersible Pumps are the products of the expertise gained from over four decades of experience,

More information

PV4 and PV6 Piston Valves

PV4 and PV6 Piston Valves 1181250/1 IM-P118-05 ST Issue 1 PV4 and PV6 Piston Valves Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning 5. Operation 6.

More information

V-Major, V-Compact. Reciprocating Compressors. Intelligent Air Technology

V-Major, V-Compact. Reciprocating Compressors. Intelligent Air Technology V-Major, V-Compact Reciprocating Compressors Intelligent Air Technology & Significant Energy Savings with Lower Running Costs Efficient. LOW POWER CONSUMPTION 75% of the running cost of an air compressor

More information

ZZYP TYPE AUTOMATIC PRESSURE REGULATING CONTROLL VALVE

ZZYP TYPE AUTOMATIC PRESSURE REGULATING CONTROLL VALVE ZZYP TYPE AUTOMATIC PRESSURE REGULATING CONTROLL VALVE OPERATION INSTRUCTION Catalogue 1. Application and feature...1 2. Structure and working principle...1-2 3. Main technical data and property index,

More information

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website: 1.0 Inspection of the product upon receipt: On receipt of the product, visually inspect the item for any evidence of shipping damage. Please note shipping damage is not covered by warranty. If shipping

More information

G type DUCTED EXHAUST SAFETY VALVE 2871 AND 288X SERIES. Model/Ref:

G type DUCTED EXHAUST SAFETY VALVE 2871 AND 288X SERIES. Model/Ref: Model/Ref: 28713 www.lauridsenindustri.com CHARACTERISTICS The G type safety valves are dedicated to protect the equipment from potential overpressure. They are automatic and close when the pressure conditions

More information

CAST IRON SAFETY VALVE TYPE 6301

CAST IRON SAFETY VALVE TYPE 6301 CHARACTERISTICS The 6301 safety valve is dedicated to protect the equipment from potential overpressure. This is an automatic device that closes when the pressure conditions are back to normal. It is a

More information

Art PRESSURE REDUCER

Art PRESSURE REDUCER FUNCTION ICMA pressure reducers are devices that reduce and stabilize the incoming pressure from the water supply. Pressure reducers allow correct use on domestic systems, reducing malfunctions due to

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 331a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated

More information

HIGH PRESSURE DRILLING FLUID PUMP

HIGH PRESSURE DRILLING FLUID PUMP 1 HDF 200/250-280 HIGH PRESSURE DRILLING FLUID PUMP Dynaset HDF pump gives great water power with small amount of water in relation to its size. As self-priming it is productive in hard environment. Small

More information

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d R e t u r n - S u c t i o n F i l t e rs E 158 E 198 E 248 Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min 20.90-5e 0.0-2d D e s c r i p t i o n Application For operation in

More information

Air Eliminators and Combination Air Eliminators Strainers

Air Eliminators and Combination Air Eliminators Strainers Description Air Eliminators and Combination Air Eliminator Strainers are designed to provide separation, elimination and prevention of air in piping systems for a variety of installations and conditions.

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S Preaction 346a 1. Description The 6 Model G-6000P Electric Release Preaction System Riser Assembly can be used as a Single Interlock Preaction System with Electric Release, or as a Double Interlock Preaction

More information

Installation and commissioning instructions 255 series and 256 series

Installation and commissioning instructions 255 series and 256 series Installation and commissioning instructions 255 series and 256 series Table of contents 1 General information... 3 1.1 About these instructions... 3 1.2 About this product... 3 1.3 Appropriate usage...

More information

Pressure and Flow Control Valves DBGM, German and European Patents

Pressure and Flow Control Valves DBGM, German and European Patents Pressure and Flow Control Valves DBGM, German and European Patents Absolutely Reliable Pressure and Flow Control In water mains of sizes DN 50 to DN 150, ERHARD Control Valves in straight or angle pattern

More information

Copyright, 2005 GPM Hydraulic Consulting, Inc.

Copyright, 2005 GPM Hydraulic Consulting, Inc. Troubleshooting and Preventive Maintenance of Hydraulic Systems Learning to Read the Signs of Future System Failures Instructed by: Al Smiley & Alan Dellinger Copyright, 2005 GPM Hydraulic Consulting,

More information

VALFONTA INSTRUCTIONS: OPERATION AND INSTALLATION PRESSURE REDUCING VALVE MODEL M2

VALFONTA INSTRUCTIONS: OPERATION AND INSTALLATION PRESSURE REDUCING VALVE MODEL M2 INSTRUCTIONS: OPERATION AND INSTALLATION PRESSURE REDUCING VALVE MODEL M2 Pressure Reducing Valve M2 - Operation and Installation - 1 - M2-13E-ENG FEBRUARY 2017 ÍNDICE PÁGINA 1 IDENTIFICATION PLATE LEGEND

More information

Mechanical Pressure Measurement

Mechanical Pressure Measurement Mechanical Pressure Measurement Differential Pressure Gauges Model GDP, Universal Version, with Diaphragm Element High Overpressure Safety PN 40, 100, 250 or 400 Applications Differential pressure measurement

More information

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type.

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type. Process Pump Series 3/5 Automatically Operated Type (Internal Switching Type)/Air Operated Type (External Switching Type) High abrasion resistance and low particle generation o sliding parts in wetted

More information

STAINLESS STEEL GRAND SERIES

STAINLESS STEEL GRAND SERIES STAINLE STEEL GRAND SERIES STAINLE STEEL GRAND SERIES DEEPWELL SUBMERSIBLE PUMPS STAINLE STEEL - GRAND SERIES C.R.I. Always equips itself in advance to face the exponentially growing technological challenges

More information

776 Cryogenic Safety Valve

776 Cryogenic Safety Valve 776 Cryogenic Safety Valve INTRODUCTION 776 Cryogenic Safety Valve The effects of exceeding safe pressure levels in an unprotected pressure vessel or system, can have catastrophic effects on both plant

More information

OPERATING INSTRUCTIONS AND PARTS LIST AUTOMATIC FILLING MACHINE DE-401-GB-AUTO

OPERATING INSTRUCTIONS AND PARTS LIST AUTOMATIC FILLING MACHINE DE-401-GB-AUTO OPERATING INSTRUCTIONS AND PARTS LIST AUTOMATIC FILLING MACHINE DE-401-GB-AUTO www.adceng.co.za P O BOX 5413, JOHANNESBURG 2000 Phone: 011 493-8209 Fax: 011 493-1459 Email: adceng@mweb.co.za P O BOX 83,

More information

Installation Operation Maintenance

Installation Operation Maintenance 682 Seal Cooler New generation seal cooler to meet and exceed the seal cooler requirements stated in the 4th Edition of API Standard 682 Installation Operation Maintenance Experience In Motion Description

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 347a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated

More information

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2 Self-operated Pressure Regulator Pressure Reducing Valve Type M 44-2 Type M 44-2, connection G 1 4, K VS = 0.15 Type M 44-2, connection G 1, K VS = 6 Fig. 1 Type M 44-2 Pressure Reducing Valve Mounting

More information

RB 4700 Commercial & Industrial Regulator

RB 4700 Commercial & Industrial Regulator RB 4700 Commercial & Industrial Regulator The RB 4700 regulator is designed for use in industrial and distribution applications such as district station and heating plants, and for industrial customers.

More information

553 Series.

553 Series. 38467.03 www.caleffi.com Pre-adjustable filling units Copyright 01 Caleffi 3 Series Function The automatic filling valve is a device consisting of a pressure reducing valve with compensating seat, visual

More information

Exercise 4-2. Centrifugal Pumps EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Pumps

Exercise 4-2. Centrifugal Pumps EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Pumps Exercise 4-2 Centrifugal Pumps EXERCISE OBJECTIVE Familiarize yourself with the basics of liquid pumps, specifically with the basics of centrifugal pumps. DISCUSSION OUTLINE The Discussion of this exercise

More information

Gas Pressure Regulator HON 502

Gas Pressure Regulator HON 502 Gas Pressure Regulator HON 502 Product information serving the gas industry worldwide Gas Pressure regulator HON 502 Application, Characteristics, Technical Data Application for offtake stations in gas

More information

ALPHADYNAMIC has filed with the TUV NORD certification body the documentation certifying

ALPHADYNAMIC has filed with the TUV NORD certification body the documentation certifying ATEX COMPLIANCE ALPHADYNAMIC has filed with the TUV NORD certification body the documentation certifying ATEX compliance pursuant to Directive 94/9/EC for its ranges of ADB BOXER pneumatic diaphragm pumps.

More information

Premium Solutions for Gas and Biogas Handling

Premium Solutions for Gas and Biogas Handling Premium Solutions for Gas and Biogas Handling Blower Solutions for Gas & Biogas Type of gas Applications Application requisites Specific characteristics of the blower unit Premium Solutions for Gas and

More information

Eaton Filtration, LLC

Eaton Filtration, LLC Eaton Filtration, LLC 900 Fairmount Avenue, Elizabeth, NJ 07207 Phone: 908-787-1000 Fax: 908-351-7893 E-Mail: filtration@eaton.com Web: www.filtration.eaton.com Installation, Operation & Service Manual

More information

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

MF2M Monnier Miniature Compressed Air Filter

MF2M Monnier Miniature Compressed Air Filter 5040050 / 2 IM-P504-02 CH Issue 2 MF2M Monnier Miniature Compressed Air Filter Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation and commissioning

More information

Magnetic Level Gauges

Magnetic Level Gauges Bulletin B 03 04 Magnetic Level Gauges Remote Reading Systems Magnetic Level Switches Magnetic level gauges OPERATING PRINCIPLE The operation of the magnetic level gauge is based on some elementary physical

More information

UIB30 and UIB30H Sealed Inverted Bucket Steam Traps for use with Pipeline Connectors

UIB30 and UIB30H Sealed Inverted Bucket Steam Traps for use with Pipeline Connectors 1130050/4 IM-P113-02 ST Issue 4 UIB30 and UIB30H Sealed Inverted Bucket Steam Traps for use with Pipeline Connectors Installation and Maintenance Instructions 1. Safety information 2. General product information

More information

DISASSEMBLY AND ASSEMBLY INSTRUCTIONS FOR LIQUID RING COMPRESSORS

DISASSEMBLY AND ASSEMBLY INSTRUCTIONS FOR LIQUID RING COMPRESSORS DISASSEMBLY AND ASSEMBLY INSTRUCTIONS FOR LIQUID RING COMPRESSORS SA INTRODUCTION These instructions are for the maintenance personnel for maintenance and repair of compressors series SA. Disassembly and

More information

Pressure Reducing Valve for Steam Type 2333 A

Pressure Reducing Valve for Steam Type 2333 A Pressure Reducing Valve for Steam Type 2333 A Fig. 1 Type 2333 A 1. Design and principle of operation The pressure reducing valve consists of a balanced control valve and a closing actuator equipped with

More information

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order Process Pump /5 Series Automatically Operated Type (Internal Switching Type)/Air Operated Type (External Switching Type) High abrasion resistance and low particle generation o sliding parts in wetted areas.

More information

Eaton Filtration, LLC

Eaton Filtration, LLC Eaton Filtration, LLC 900 Fairmount Avenue, Elizabeth, NJ 07207 Phone: 908-787-1000 Fax: 908-351-7893 E-Mail: filtration@eaton.com Web: www.filtration.eaton.com Installation, Operation & Service Manual

More information

Operating Instructions Models and Hydrostatic Test Pumps

Operating Instructions Models and Hydrostatic Test Pumps Operating Instructions Models 46501 and 465010 Hydrostatic Test Pumps 46501 DIMENSIONS: WEIGHT: PUMP: ENGINE: CONTROL: GAUGE: DISCHARGE HOSE: INLET HOSE: 28 (70cm) L x 24 (60cm) W x 35 (87.5cm) H 136 lbs.

More information

TECHNICAL DATA Q= C. Table 1 - Specifications

TECHNICAL DATA Q= C. Table 1 - Specifications September 25, 2013 Pressure Regulation 537a 1. Description The Model B-3 Pilot Operated Pressure Control Valve is a factory assembled unit. The unit consists of a Model J-2 Halar coated Flow Control Valve,

More information

Pump Selection and Sizing (ENGINEERING DESIGN GUIDELINE)

Pump Selection and Sizing (ENGINEERING DESIGN GUIDELINE) Guidelines for Processing Plant Page : 1 of 64 Feb 2007 (ENGINEERING DESIGN GUIDELINE) Author: A L Ling Checked by: Karl Kolmetz TABLE OF CONTENT INTRODUCTION Scope 5 General Design Consideration Type

More information

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors 0862050/1 IM-P086-18 MI Issue 1 Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors Installation and Maintenance Instructions 1. Safety Information 2. General product information 3. Installation 4.

More information

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3, 4, 6 Data Sheet 819584-00 Issue Date: 01/17 Ball Float Steam Trap UNA 43 PN 16/C 125/JIS 10K UNA 46 PN 40/C 150/C 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6" UNA 43 hl, UNA 46 hl UNA 43 v, UNA 46 v with

More information

SAMPLING SYSTEMS FOR LIQUIDS, GASES AND OTHERS APPLICATIONS.

SAMPLING SYSTEMS FOR LIQUIDS, GASES AND OTHERS APPLICATIONS. SAMPLING SYSTEMS FOR LIQUIDS, GASES AND OTHERS APPLICATIONS. SAMPLING SYSTEMS CONTENTS 1. SAMPLING SYSTEMS OVERVIEW...Pag. 3-4 2. LIQUID SAMPLING SYSTEM ESV SERIES ESV STANDARD CONFIGURATION...Pag. 5-6

More information

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm Return-Suction Filters E 08 Tank top mounting Connection up to G / -6 SE Nominal flow rate up to 80 l/min /. gpm Description pplication For operation in units with hydrostatic drives, when the return flow

More information

SCA Series Inverted Bucket Steam Traps

SCA Series Inverted Bucket Steam Traps 0770050/5 IM-P077-06 ST Issue 5 SCA Series Inverted Bucket Steam Traps Installation and Maintenance Instructions 1. General safety information 2. General product information 3. Installation 4. Commissioning

More information

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company CIF A Tyco International Company 1 Foam Concentrate CIF 3% AFFF -UL Listed -UL Canada Listed 6% AFFF 6 parts AFFF concentrate to 94 parts water -UL Listed- Foam Liquid -UL Canada Listed 3% FLUOROPROTEIN

More information