Radiation-based Overview Page 214 FIBERTRAC Page 216 SOLITRAC Page 218 MINITRAC Page 220 POINTRAC Page 222 WEIGHTRAC Page 224
|
|
- Sandra Cook
- 5 years ago
- Views:
Transcription
1 Detectors Radiation-based Overview Page 214 FIBERTRAC Page 216 SOLITRAC Page 218 MINITRAC Page 220 POINTRAC Page 222 WEIGHTRAC Page
2 FIBERTRAC, SOLITRAC, MINITRAC, POINTRAC, WEIGHTRAC Radiation-based sensors for level, density and mass flow measurement Measuring principle In the radiation-based measurement, a Caesium 137 or Cobalt 60 isotope emits focused gamma rays. A special sensor located at the opposite side of the vessel receives this radiation. The so called scintillator converts the gamma rays into signals, their number is detected and processed. Because gamma rays are damped when penetrating the substance, the sensor can calculate the level, the limit level, the density or the mass flow out of the received radiation. Applications Level measurement With FIBERTRAC and SOLITRAC level changes are contactlessly measured through the vessel wall. Since the measuring facility is mounted on the outside of the vessel, the measurement is insensitive to extreme process conditions. Also measurements on pressurized vessels or on vessels with agitators can be simply realized. For round vessel forms the flexible FIBERTRAC is recommended, which can be simply mounted on the vessel. A high reliability can be reached with SOLITRAC on cylindrical vessels. The sensors are cascadable for very large measuring ranges. Density measurement The non-contact, continuous density and concentration measurement of liquids and bulk solids with MINITRAC is suitable for pipelines and vessels. The measuring principle is independent of aggressive products and ensures a high reliablity. The sensor mounting is carried out on existing pipelines. With small tube diameters an inclined radiation or the use of a measuring track is recommended. In case there is also a temperature sensor connected, then MINITRAC takes the heat expansion of the medium into account. Furthermore the mass flow of MINITRAC can be calculated with the signal of a flow volume measuring instrument. This ensures reliable measurement results and permanent process continuity even with extreme process conditions. Flow measurement The WEIGHTRAC determines contactlessly the exact delivery volume of solids. Through the frame construction, the sensor can be simply mounted to the conveyor belt. The measurement runs wear and maintenance-free. A simple and reliable adjustment of the sensor saves time during setup. The WEIGHTRAC is suitable for conveyor systems, for example conveyor belt weighers, screw conveyors, chain trough conveyors, steel plate conveyors, bucket conveyors. 214 Radiation-based PROTRAC
3 Overview Instrument type Version Measuring range Process fitting Reproducibility FIBERTRAC 31 Sensor with flexible plastic detector ø 42 mm up to 7 m From outside on the vessel ± 0.5 % SOLITRAC 31 Sensor with PVT rod detector up to 3 m From outside on the vessel ± 0.5 % MINITRAC 31 Sensor with integrated NaI detector --- From outside on the vessel or on pipelines ± 0.1 % POINTRAC 31 Sensor with PVT rod detector up to 305 mm From outside on the vessel or on pipelines --- WEIGHTRAC 31 Sensor with PVT rod detector up to 1600 mm Through supplied measuring frame ± 1 % of measuring range final value Radiation-based Radiation-based PROTRAC 215
4 FIBERTRAC 31 Radiation-based sensor for continuous level and interface measurement Application area The FIBERTRAC 31 is a radiation-based sensor for continuous measurement of liquids and bulk solids. It is suitable for level and interface measurement under extreme process conditions, in aggressive products or critical product features. The FIBERTRAC 31 delivers precise measuring results even under hardest application conditions. Your benefit High plant availability through non-contact measurement Simple mounting on round and conical vessels through flexible detector Cost saving through use of only one sensor up to 7 m measuring range Technical data Version: sensor with flexible plastic detector ø 42 mm Measuring range: up to 7 m Mounting: from outside on the vessel Reproducibility: +/- 0.5 % SIL qualification: optionally up to SIL2 ø 85,7 mm (3.37") 61,4 mm (2.42") 111,5 mm (4.39") L Measuring length 180 mm (7.09") 291 mm (11.46") 143,6 mm (5.65") 50 mm (1.97") L ø 42 mm (1.58") You will find further process fittings and options under You will find further drawings and tables under You will find mounting accessory, welded sockets and housing overviews in chapter "Accessory". 216 Radiation-based FIBERTRAC 31
5 Approval XX Without... DK ATEX II 2G Ex d ia IIC T6+1D,2D Ex td IP66 T... TX ATEX IM 2 (M1) Ex d [ia Ma] I Mb... DK IEC Zone 1 Ex d ia IIC T6+Ex td A20,A21 IP66 T... TX IEC Ex d [ia Ma]I Mb... Version / Ambient temperature 1 Standard / -20º...+50ºC... Electronics V Four-wire mA/HART... S Four-wire mA/HART with SIL qualification... A Four-wire ma/hart (Explosion Proof Output)... I Four-wire ma/hart (Explosion Proof Output) SIL... L Four-wire ma/hart (Intrinsic. Safe Output) SIL... F Four-wire Foundation Fieldbus... C Four-wire Foundation Fieldbus (Explosion Proof Output)... P Four-wire Profibus PA... E Four-wire Profibus PA (Explosion Proof Output)... Housing / Protection D Aluminum / IP66/IP67... W 316L SS / IP66/IP67... Cable entry / Cable gland / Plug connection M M20x1.5 / with / without... N 1/2 NPT / without / without... Indicating / Adjustment module (PLICSCOM) X Without... B Side mounted with backlight... Additional equipment X without... Active length A mm... A mm... A mm... A mm... A mm... A mm... A mm... A mm... A mm... A mm... A mm... A mm... A mm... Radiation-based FT31. Radiation-based FIBERTRAC
6 SOLITRAC 31 Radiation-based sensor for continuous level and interface measurement Application area The SOLITRAC 31 is a radiation-based sensor with PVT rod detector for continuous measurement of liquids and bulk solids. It is suitable for level and interface measurement under extreme process conditions, with critical product features or in aggressive products. The SOLITRAC 31 is ideal for use in cylindircal vessels, reactors, autoclaves, separators and mixing vessels. Your benefit High plant availability through non-contact measurement Best measurement performance through PVT detector with maximum sensitivity Simple mounting through supplied accessory Technical data Version: sensor with PVT rod detector Measuring range: up to 3 m Mounting: from outside on the vessel Reproducibility: +/- 0.5 % SIL qualification: optionally up to SIL2 ø 85,7 mm (3.37") 61,4 mm (2.42") 111,5 mm (4.39") L Measuring length 143,6 mm (5.65") ø 76,2 mm (3") 36 mm (1.42") L 180 mm (7.09") 256 mm (10.08") You will find further process fittings and options under You will find further drawings and tables under You will find mounting accessory, welded sockets and housing overviews in chapter "Accessory". 218 Radiation-based SOLITRAC 31
7 ST31. Approval XX Without... DK ATEX II 2G Ex d ia IIC T6+1D,2D Ex td IP66 T... TX ATEX IM 2 (M1) Ex d [ia Ma] I Mb... DK IEC Zone 1 Ex d ia IIC T6+Ex td A20,A21 IP66 T... TX IEC Ex d [ia Ma]I Mb... Version / Ambient temperature 1 Standard / -40º...+60ºC... Electronics V Four-wire mA/HART... S Four-wire mA/HART with SIL qualification... A Four-wire ma/hart (Explosion Proof Output)... I Four-wire ma/hart (Explosion Proof Output) SIL... L Four-wire ma/hart (Intrinsic. Safe Output) SIL... F Four-wire Foundation Fieldbus... C Four-wire Foundation Fieldbus (Explosion Proof Output)... P Four-wire Profibus PA... E Four-wire Profibus PA (Explosion Proof Output)... Housing / Protection D Aluminum / IP66/IP67... W 316L SS / IP66/IP67... Cable entry / Cable gland / Plug connection M M20x1.5 / with / without... N 1/2 NPT / without / without... Indicating / Adjustment module (PLICSCOM) X Without... B Side mounted with backlight... Additional equipment X without... Length A mm... A mm... A mm... A mm... A mm... A mm... Radiation-based Radiation-based SOLITRAC
8 MINITRAC 31 Radiation-based sensor for density measurement Application area The MINITRAC 31 is a radiation-based sensor for non-contact density measurement of liquids and bulk solids. The MINITRAC 31 determines the density contactlessly from outside through pipelines or the vessel wall. Through its compact design it is ideal for mounting in positions hardly to access and in narrow space applications. Your benefit Simple retrofitting during production processes High plant availability through non-contact measurement Exact measuring results independent of the process conditions Technical data Version: sensor with integrated NaI detector Mounting: from outside on pipelines or the vessel Reproducibility: +/- 0.1 % SIL qualification: optionally up to SIL2 ø 85,7 mm (3.37") 61,4 mm (2.42") 111,5 mm (4.39") 180 mm (7.09") 291 mm (11.46") 143,6 mm (5.65") You will find further process fittings and options under You will find further drawings and tables under You will find mounting accessory, welded sockets and housing overviews in chapter "Accessory". 220 Radiation-based MINITRAC 31
9 Approval XX Without... DK ATEX II 2G Ex d ia IIC T6+1D,2D Ex td IP66 T... TX ATEX IM 2 (M1) Ex d [ia Ma] I Mb... DK IEC Zone 1 Ex d ia IIC T6+Ex td A20,A21 IP66 T... TX IEC Ex d [ia Ma]I Mb... Version / Ambient temperature 1 Standard / -40º...+60ºC... Electronics V Four-wire mA/HART... S Four-wire mA/HART with SIL qualification... A Four-wire ma/hart (Explosion Proof Output)... I Four-wire ma/hart (Explosion Proof Output) SIL... L Four-wire ma/hart (Intrinsic. Safe Output) SIL... F Four-wire Foundation Fieldbus... C Four-wire Foundation Fieldbus (Explosion Proof Output)... P Four-wire Profibus PA... E Four-wire Profibus PA (Explosion Proof Output)... Housing / Protection D Aluminum / IP66/IP67... W 316L SS / IP66/IP67... Cable entry / Cable gland / Plug connection M M20x1.5 / with / without... N 1/2 NPT / without / without... Indicating / Adjustment module (PLICSCOM) X Without... B Side mounted with backlight... Additional equipment X without... S Int. lead coating to protect against ambient radiation... MT31. Radiation-based Radiation-based MINITRAC
10 POINTRAC 31 Radiation-based sensor for level detection Application area The POINTRAC 31 is a radiation-based sensor for universal level detection of liquids and bulk solids. Independent of the mounting location, it monitors reliably the limit level in vessels. The sensor can be used for applications in all industries. Due to the high sensitivity POINTRAC 31 is an economical solution with minimum radiation activity. Your benefit Exact measuring results independent of process conditions High process reliability through determination of buildup Economical level detection under arduous application conditions Technical data Version: Measuring range: Mounting: SIL qualification: sensor with PVT rod detector up to 305 mm from outside on the pipeline or vessel optionally up to SIL2 ø 85,7 mm (3.37") 61,4 mm (2.42") 111,5 mm (4.39") 143,6 mm (5.65") ø 76,2 mm (3") 36 mm (1.42") 180 mm (7.09") L 256 mm (10.08") You will find further process fittings and options under You will find further drawings and tables under You will find mounting accessory, welded sockets and housing overviews in chapter "Accessory". 222 Radiation-based POINTRAC 31
11 PT31. Approval XX Without... DK ATEX II 2G Ex d ia IIC T6+1D,2D Ex td IP66 T... TX ATEX IM 2 (M1) Ex d [ia Ma] I Mb... DK IEC Zone 1 Ex d ia IIC T6+Ex td A20,A21 IP66 T... TX IEC Ex d [ia Ma]I Mb... Version / Ambient temperature 1 Standard / -40º...+60ºC... Electronics V Four-wire 8/16 ma/hart... S Four-wire 8/16 ma/hart with SIL qualification... A Four-wire 8/16 ma/hart (Ex d output)... I Four-wire 8/16 ma/hart (Ex d output) w. SIL qualif.... L Four-wire 8/16 ma/hart (Ex ia output) w. SIL qualif.... F Four-wire Foundation Fieldbus... C 4-wire Foundation Fieldbus (Explosion Proof Output)... P Four-wire Profibus PA... E 4-wire Profibus PA (Explosion Proof Output)... Housing / Protection D Aluminum / IP66/IP67... W 316L SS / IP66/IP67... Cable entry / Cable gland / Plug connection M M20x1.5 / with / without... N 1/2 NPT / without / without... Indicating / Adjustment Module (PLICSCOM) X Without... B Side mounted with backlight... Additional equipment X without... Length mm mm... Radiation-based Radiation-based POINTRAC
12 WEIGHTRAC 31 Radiation-based sensor for mass flow determination Application area The WEIGHTRAC 31 is a radiation-based sensor for precise flow measurement of bulk solids. It is ideal for mass flow determination on conveyor belts and in conveyor spirals in all industries. Due to its frame construction, the WEIGHTRAC 31 can be simply retrofitted on the conveyor belt. Your benefit Wear-free, because non-contact measurement Exact determination of the delivery volume through simple setup Technical data Version: Measurement width: Mounting: Accuracy: sensor with PVT rod detector up to 1600 mm through the supplied measurement frame +/- 1 % of the measuring range final value B 30 mm (1.81") 30 mm (1.81") Note: Source container not in the scope of delivery A E D 136 mm (5.35") 70 mm (2.76") 122 mm (4.80") C 70 mm (2.76") You will find further process fittings and options under You will find further drawings and tables under You will find mounting accessory, welded sockets and housing overviews in chapter "Accessory". 224 Radiation-based WEIGHTRAC 31
13 WT31. Approval XX Without... DK ATEX II 2G Ex d ia IIC T6+1D,2D Ex td IP66 T... TX ATEX IM 2 (M1) Ex d [ia Ma] I Mb... DK IEC Zone 1 Ex d ia IIC T6+Ex td A20,A21 IP66 T... TX IEC Ex d [ia Ma]I Mb... Version / Ambient temperature 1 Standard / -40º...+60ºC... Electronics V Four-wire mA/HART... A Four-wire ma/hart (Explosion Proof Output)... F Four-wire Foundation Fieldbus... C Four-wire Foundation Fieldbus (Explosion Proof Output)... P Four-wire Profibus PA... E Four-wire Profibus PA (Explosion Proof Output)... Housing / Protection D Aluminum / IP66/IP67... W 316L SS / IP66/IP67... Cable entry / Cable gland / Plug connection M M20x1.5 / with / without... N 1/2 NPT / without / without... Indicating / Adjustment module (PLICSCOM) X Without... B Side mounted with backlight... Additional equipment X without... Frame construction A LCS w/epoxy Powder Coating... C 316L SS... Conveyor width (A) N1 500 mm... P1 800 mm... Q mm... R mm... S mm... Source holder configuration B Single SHLD-1 mounting plate... D Dual SHLD-1 mounting plates... Radiation-based Radiation-based WEIGHTRAC
14 226 Radiation-based
Radiation-based. 166 Overview PROTRAC 170 FIBERTRAC SOLITRAC POINTRAC MINITRAC WEIGHTRAC VEGASOURCE 31, 35
Radiation-based 166 Overview PROTRAC 170 FIBERTRAC 31 172 SOLITRAC 31 174 POINTRAC 31 176 MINITRAC 31 178 WEIGHTRAC 31 180 VEGASOURCE 31, 35 184 Radiation capsule 185 Mounting bracket, water/air coolings
More informationUltrasonic. Continuous level measurement. Overview Page 64 VEGASON series 60 Page 66 AL-EN
Ultrasonic Continuous level measurement Overview Page 64 VEGASON series 60 Page 66 6 VEGASON Non-contact measurement with ultrasonics Measuring principle Short ultrasonic pulses in the range of 5 to 70
More informationUltrasonic. 58 Overview VEGASON 60 VEGASON 61, 62, 63
Ultrasonic 58 Overview VEGASON 60 VEGASON 61, 62, 63 57 Overview VEGASON Area of application The ultrasonic sensors of the VEGASON series are suitable for non-contact level measurement of liquids and bulk
More informationHydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN
Hydrostatic Continuous level measurement 8 Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 187 Hydrostatic Level and pressure measurement Measuring principle The pressure
More informationDifferential pressure
Differential pressure 9 Overview Page 200 VEGADIF 65 Page 202 Chemical seal Page 204 Accessory Page 208 199 VEGADIF For differential pressure, level and flow measurements Measuring principle The sensor
More informationTDR Guided Wave Radar
TDR Guided Wave Radar Continuous level measurement evel Overview Page 48 VEGAFEX series 80 Page 50 47 VEGAFEX Universal sensors for liquids and bulk solids Measuring principle High frequency microwave
More informationLevel, Pressure, and Density Instrumentation for the Petrochemical Industry
Level, Pressure, and Density Instrumentation for the Petrochemical Industry Application Examples and Products Measurement technology for the petrochemical industry This brochure presents examples of applied
More informationProduct information. Capacitive. Level detection with bulk solids VEGACAP 62 VEGACAP 65 VEGACAP 66 VEGACAP 67. Document ID: 29982
Product information Level detection with bulk solids VEGACAP 62 VEGACAP 65 VEGACAP 66 VEGACAP 67 Document ID: 29982 Contents Contents 1 Description of the measuring principle... 3 2 Type overview... 5
More informationProduct information. Capacitive. Level detection in liquid VEGACAP 62 VEGACAP 63 VEGACAP 64 VEGACAP 66 VEGACAP 69. Document ID: 29983
Product information Level detection in liquid VEGACAP 62 VEGACAP 63 VEGACAP 64 VEGACAP 66 VEGACAP 69 Document ID: 29983 Contents Contents 1 Description of the measuring principle... 3 2 Type overview...
More informationTorque Tube TB300 Digital Transmitters
Page 1 of 7 7E.300-E Issue 4-2009 Description Series TB300 torque tube liquid level instruments utilize the buoyancy exerted on a displacer when immersed in a liquid. The buoyancy on the displacer is proportional
More informationProduct information. Capacitive. Level measurement in liquid VEGACAL 62 VEGACAL 63 VEGACAL 64 VEGACAL 66 VEGACAL 69. Document ID: 30138
Product information Level measurement in liquid VEGACAL 6 VEGACAL 6 VEGACAL 64 VEGACAL 66 VEGACAL 69 Document ID: 08 Contents Contents Description of the measuring principle... Type overview... 5 Housing
More informationSITRANS P measuring instruments for pressure
SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and
More informationProduct information Vibrating
Product information Level detection in bulk solids VEGAVIB 61 VEGAVIB 62 VEGAVIB 63 VEGAWAVE 61 VEGAWAVE 62 VEGAWAVE 63 Document ID: 29438 Contents Contents 1 Description of the measuring principle...
More information1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI
Siemens AG 06 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure
More information1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition
Siemens AG 07 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure
More informationElectropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765
Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765 Application Single-acting positioner for attachment to pneumatic control valves. Supplied with either an electric input signal from
More informationPressure Measurement Single-range transmitters for general applications
Siemens AG 07 Overview Function U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/ Equipotential bonding Diaphragm The pressure
More information1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure
Siemens AG 204 Overview The pressure transmitter SITRANS P220 measures the gauge pressure of liquids, gases and vapors. Stainless steel measuring cell, fully welded Measuring ranges 2.5 to 600 bar (36.3
More informationHow to specify a product. Process Sensors and Mechanical Instruments
How to specify a product Process Sensors and Mechanical Instruments Keep the overview. Here is some guideline information on how to specify our products. Intended as supplementary help to specification
More informationPressure measurement is a family affair
Get to know the team of specialists! Process Instrumentation Pressure measurement is a family affair Discover our P family. usa.siemens.com/pressure Whether it be hygienic requirements or rugged and harsh
More informationCertified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters
www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass
More informationSeries INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN
INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries Series 2000 ALL STAINLESS DESIGN EASY CALIBRATION WITHOUT TEST PRESSURE BY 3 PUSH BUTTONS ACCURACY 0,1% 4-20 ma AND HART PROTOCOL ATEX II
More informationLevel transmitter LT 100
KROHNE 09/2001 7.02363.21.00 GR/PRINTO Level transmitter LT 100 Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters
More informationUser s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E
User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] 12th Edition 1 1. Introduction Thank you for purchasing the DPharp electronic pressure transmitter. This manual
More informationPressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview
f gauge pressure Siemens AG 010 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection
More informationATM.1ST/Ex - High Precision Transmitter
Pressure Transmitter - ATEX / IECEx certified ATM.1ST/Ex - High Precision Transmitter CUSTOMER BENEFITS Certificate: ATEX, IECEx & EAC High measurement accuracy is ensured by sophisticated digital temperature
More informationTechnical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications
Technical Datasheet D Series SMART Pressure Transmitter Model: DPC-2000 Key Features ATEX - Flameproof and Intrinsically Safe IECEx - Flameproof and Intrinsically Safe SIL 2 certificate Compliant to NAMUR
More informationSeries INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN
INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries Series 2000 ALL STAINLESS DESIGN EASY CALIBRATION WITHOUT TEST PRESSURE BY 3 PUSH BUTTONS ACCURACY 0,1% 4-20 ma AND HART PROTOCOL ATEX II
More informationPressure measurement is a family affair
Get to know the team of specialists! Process Instrumentation Pressure measurement is a family affair Discover our P family. siemens.com/pressure-measurement Whether it be hygienic requirements or rugged
More informationTwo-Wire In Situ Oxygen Analyzer (550 to 1400 C)
Product Data Sheet PDS 106-581.A01 March, 2004 Model 5081FG Two-Wire In Situ Oxygen Analyzer (550 to 1400 C) Intrinsically safe: - CENELEC EEx ia IIC - Class I Div. I Gr. B, C, D (pending) Operates at
More informationTYPE APPROVAL CERTIFICATE
TYPE APPROVAL CERTIFICATE Certificate No: TAA0000123 This is to certify: That the Pressure Transmitter with type designation(s) SITRANS P series DS III, P310, P410 Issued to Siemens AG - Process Industries
More informationFlow metering in gases Introduction to COMBIMASS family
Flow metering in gases Introduction to COMBIMASS family - physical principle, basic information - different types of instruments, pricing & delivery time Sales Training Germany October 17 th to 19 th,
More information1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition
Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.
More informationFlow Measurement SITRANS F C
Overview High-pressure program as standard The sensor calibration factor is also valid for gas measurement. SITRANS FC00 is a compact Coriolis mass sensor suitable for flow measurement of a variety of
More informationPetrochemical Industry
Petrochemical Industry Contents VEGA sets the standard in the petrochemical industry 3 Measurement technologies for a demanding industry 4 plics the idea with a future 6 PLICSCOM and PACTware 8 Pipeline
More informationA Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >
A Higher Level of Performance Data Sheet Pressure and Level Transmitters For more information, please visit > www.hawkmeasure.com Description Intelligent pressure and level transmitters for all industries
More informationL (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.:
Smart level probe type APC-2000ALW/L Programmable zero shift, range and damping ratio 4...20 ma output signal + HART protocol Accuracy 0,16% Local display Intrinsic safety certificate (ATEX, IECEx) II
More informationVG5 Supplementary instructions
VG5 Supplementary instructions 2-wire / 10 GHz Radar (FMCW) Level Meter Supplementary Instructions for ATEX applications HYCONTROL CONTENTS VG5 1 General safety information 4 1.1 Scope of the document...
More information2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure
Z series for gage pressure Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection
More informationTechnical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection
0102 Model Number Features Direct mounting on standard actuators Compact and stable housing Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up to SIL2 acc. to IEC 61508 Accessories
More informationBourdon tube pressure gauge for diaphragm seals
Bourdon tube pressure gauge for diaphragm seals and switch function, Type series BR42.. Features Bourdon tube pressure gauge for diaphragm seal and switch function Nominal range -1 3 bar to -1 15 bar,
More informationELECTRIC ACTUATORS for continuous underwater use
ELECTRIC ACTUATORS for continuous underwater use The SA multi-turn actuator for continuous underwater use by AUMA opens new applications for electric actuators for water supply, in hydropower plants and
More informationElectropneumatic Positioner and Pneumatic Positioner Type 3760 JIS
Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. Supplied with an electric input signal of 4 to 20
More informationLMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.
LMP 07 Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % / 0. % FSO Nominal pressure from 0... mho up to 0... 50 mho Output signals -wire: 4... 0 ma -wire: 0...
More informationBrief Operating Instructions Gammapilot M FMG60
KA01092F/00/EN/14.12 71207228 Products Solutions Services Brief Operating Instructions Gammapilot M FMG60 Radiometric Measurement These Instructions are Brief Operating Instructions; they do not replace
More informationSmart performance with innovative and ever-strong coil drive even under harsh working environments
Smart Valve Positioner SS2 inear / Rotary Smart performance with innovative and ever-strong coil drive even under harsh working environments Easy and quick auto-calibration Detecting RA (reverse acting)
More informationExpert Hydrostatic Level Transmitters
Expert Hydrostatic s General Features MJK Expert hydrostatic level transmitters are designed for level measurement by submerging the transmitter in open channels, drains and tanks. Expert hydrostatic level
More informationPressure Measurement Single-range transmitters for general applications
Siemens A 207 Overview Application The SITRANS P Compact pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials
More informationJUMO dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO)
Data Sheet 202610 Page 1/12 JUMO dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO) with optional terminal box or operating unit Type 202610 Two-wire transmitter JUMO dtrans O2 01 Brief description
More informationbetter measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.
Simply a question of better measurement SCHMIDT Flow Sensor SS 20.261 The cost-effective alternative in pressurised systems up to 10 bars. Compressed air technology Industrial processes A cost analysis
More informationMagnetic level switch type MR783 Instruction Manual
Magnetic level switch Magnetic level switch type MR783 1. DESCRIPTION page 3 1.1 Operation page 3 1.2 Application page 3 1.3 Description page 3 2. SPECIFICATIONS page 3 2.1 Service Conditions page 4 2.2
More informationCompact differential pressure switch Flameproof enclosure Ex d Models DE, DEC
Mechatronic pressure measurement Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC WIKA data sheet PV 35.41 Process Compact Series Applications Differential pressure monitoring
More informationATM.ECO/IS - Analog Transmitter with Temperature compensation
Pressure Transmitter - FM / FM-C certified ATM.ECO/IS - Analog Transmitter with Temperature compensation CUSTOMER BENEFITS Certificate: FM, FM-C & IECEx & ATEX Entry level series into precision pressure
More informationPressure Measurement Single-range transmitters for general applications
Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.
More informationFAS-W. Features. Applications. Automatic condensation hygrometer
FAS-W HUMIDITY ANALYZER Automatic condensation hygrometer the «FAS-W» Moisture Analyzer automatic condensation hygrometer can measure both the volume fraction of moisture and the dew point temperature
More informationMicro Motion 3098 Gas Specific Gravity Meter
Product Data Sheet PS-001188, Rev. B April 2009 Micro Motion 3098 Gas Specific Gravity Meter Micro Motion density and concentration meters are built to tackle the most demanding process and fiscal applications.
More informationSafety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85
XA01537F-A/00/EN/01.16 71333275 Products Solutions Services Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85 0Ex ia IIC T6 Ga X Ga/Gb Ex ia IIC T6 X Document: XA01537F-A Safety instructions
More informationLevel MEASUREMENT 1/2016
Level MEASUREMENT 1/2016 AGENDA 2 A. Introduction B. Float method C. Displacer method D. Hydrostatic pressure method E. Capacitance method G. Ultrasonic method H. Radar method I. Laser method J. Level
More informationSiemens AG psi (6 bar) 145 psi (10 bar) 464 psi (32 bar) 1450 psi (100 bar) 3626 psi (250 bar) 8700 psi (600 bar) psi (800 bar)
Technical specifications SITRANS P, DS III series Input Measured variable Spans (infinitely adjustable) or nominal measuring range and max. permissible test pressure HART Gauge pressure Span (min.... max.)
More informationNivuBar Plus II
NivuBar Plus II Ceramic diaphragm Capacitive measuring cell 2-wire technology (output 4-20 ma) Integrated overload protection Extensive, almost front flush diaphragm Ex approval for zone 0 as standard
More informationVersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.
VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet 34-VF-03-05 September 3rd, 2008 Specification The all-in-one solution The VERSAFLOW is the only vortex flowmeter with integrated pressure and
More informationLiquid level switch BM 34
KROHNE 09/2001 7.02370.21.00 GR/PRINTO Liquid level switch Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level
More informationATM/Ex - Analog Pressure Transmitter
Pressure Transmitter - ATEX certified ATM/Ex - Analog Pressure Transmitter CUSTOMER BENEFITS Certificate: ATEX & EAC Fast customization thanks to configurable product design Demountable electrical connector
More informationUHrasonic Sensor VEGASON60 type series SN6*.CI**H***
Certificate No.: IECEx PTa 06.0099X Issue No.: 0 Status: Current Date of Issue: 2006-12-27 Page 1 of 3 Applicant: VEGA Grieshaber KG Am Hohenstein 113 77761 Schiltach Germany Electrical Apparatus: Optional
More informationATM/Ex - Intrinsically Safe Analog Pressure Transmitter - ATEX / IECEx Certified
Intrinsically safe pressure transmitters ATM/Ex - Intrinsically Safe Analog Pressure Transmitter - ATEX / IECEx Certified CUSTOMER BENEFITS Certificate: ATEX & IECEx Fast customization thanks to configurable
More informationPressure transmitter PASCAL Ci4
Pressure transmitter PASCAL Ci4 for general application,type Series CI4100 Features Pressure transmitter for the measuring of relative and absolute pressures of gases, vapors and liquids High-resolution
More informationTF- & DM-Series. Turbineflowmeter
Turbineflowmeter .. are the ideal solution for measuring applications in liquids when high accuracy, very fast response times, compact design, high reliability are also required in continuous operation
More informationDimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm
Dimensions 65 GW2 40 35 9 5 GW1 14 11 9 5.4 M20 x 1.5 0102 Model Number S M12 x 1.5 Features 77.5 LED V Direct mounting on standard actuators Compact and stable housing with terminal compartment connection
More informationMiniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800
KROHNE 1/22 7.236.22. GR Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 8 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters
More informationC-Flow Coriolis Mass Flow Meters
Coriolis Mass Flow Meters Ready for Take Off The New Compact C-Flow Küppers Elektromechanik GmbH The C-Flow The C-Flow Coriolis Mass Meters consist of two components: KCE Transmitter KCM Transducer 2 KEM
More informationReliable, low-maintenance pressure measurement with SITRANS P
Processes require precision Reliable, low-maintenance pressure measurement with SITRANS P www.usa.siemens.com/pressure Pressure measurement under control It s impossible to imagine today s process industries
More informationOPTIBAR P 1010 C Technical Datasheet
Technical Datasheet Pressure transmitter with recessed diaphragm for general applications Wide variety thanks to modular design Measuring ranges up to 250 bar / 3750 psi High overload and temperature stability
More informationLevel measurement. Continuous level measurement Guided wave radar transmitters. SITRANS LG series. 4/208 Siemens FI
Siemens AG 201 Overview The Siemens are guided wave radar transmitters for level, level/interface, and volume measurement of liquids and solids. The Sitrans LG product line can handle changes in process
More informationPressure Transmitters 36 F-27839
Pressure Transmitters 36 F-27839 SPD310/SPD360 Air Differential schneider-electric.com 37 SPD310/SPD360 SPD310/SPD360 differential pressure transmitters are intended for use in air handling systems for
More informationPoint Level Measurement. Switching Technology for Liquid and Solid Level Measurement
Point Level Measurement Switching Technology for Liquid and Solid Level Measurement Contents Leadership in Level Switching 3 About Level Switching 4 plics Easy is Better 6 VEGAVIB 61, 62, and 63 Measurement
More informationLevel detection in bulk solids. Vibration VEGAVIB VEGAWAVE Product Information
Level detection in bulk solids Vibration VEGAVIB 61-63 VEGAWAVE 61-63 Product Information Contents Contents 1 Description of the measuring principle...........................................................
More informationOxymax W COS51D. Technical Information. Digital sensor for measuring dissolved oxygen Membrane-covered amperometric sensor
Technical Information Oxymax W COS51D Digital sensor for measuring dissolved oxygen Membrane-covered amperometric sensor Application The continuous measurement of the concentration of dissolved oxygen
More informationTechnical Data. Dimensions
00 Model Number Features mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,
More informationOSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide
OSAT Series Intrinsically Safe Infrared Temperature Sensor Operator's Guide Issue L Jan 2017 Introduction OSAT Series intrinsically safe non-contact infrared temperature sensors measure the temperature
More informationDPZ-plus. Application example. Pneumatic 3-Finger Centric Grippers Sealed Grippers. Gripping force 520 N N. Sizes
DPZ-plus Sizes 64.. 200 Weight 0.62 kg.. 20.1 kg Gripping force 520 N.. 16800 N Stroke per finger 3 mm.. 25 mm Workpiece weight 2.6 kg.. 60.0 kg Application example Insertion tool for assembling small
More informationSPD310/SPD360 Air Differential
SPD310/SPD360 Air Differential Pressure SPD310 / SPD360 SPD310 / SPD360 differential pressure transmitters are intended for use in air handling systems for the monitoring of air ducts, filters and fans.
More informationPro-V Multivariable Flowmeter Model M22 In-line Vortex
Pro-V Multivariable Flowmeter Model M22 In-line Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,
More informationLevel transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids
Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids No contact with the product Compact design with polycarbonate housing (electronics and display).
More informationUltrasonic level transmitter and indicator
Ultrasonic level transmitter and indicator No contact with the product Compact design with polycarbonate housing (electronics and display). Remote display available on request Very good resistance in corrosive
More informationTGD-L (LP) Tank Gauging Device TGD L (Level) TGD LP (Level Pressure) Main features:
Product data sheet TGD-L (LP) Main features: Automatic signal self-calibration reflectors in every the tank, 2 seconds the acoustic Less cabling signal only is guided 2 wires in a steel pipe going Non-contact
More informationdtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO)
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net
More informationATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE
ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE ATEX CHEMISTRY DIAPHRAGM PUMPS. ATEX VARIO CHEMISTRY DIAPHRAGM PUMPS. Chemistry diaphragm pumps, vacuum systems and gauges for use in
More informationDMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.
Pressure Transmitter for Marine and Offshore Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0. % FSO Nominal pressure from 0... 40 mbar up to 0... 0 bar Output signals -wire:
More informationLevel switches Series LD Vibrating fork level switch for liquids and solids
Level switches Series LD Vibrating fork level switch for liquids and solids Robust and compact Suitable for liquids (model LD61) and solids (model LD60) No moving parts, low maintenance Corrosion resistant
More informationLiquid level instruments BM 24 /BM 51
KROHNE 09/2001 7.02362.21.00 GR/PRINTO Liquid level instruments / Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters
More informationOperating Instructions VEGAPULS 66
Operating Instructions VEGAPULS 66 4 20 ma/hart two-wire Radar Contents Contents 1 About this document 1.1 Function.................................. 4 1.2 Target group.............................. 4
More informationFor the highest operational safety around the clock
Byworth Boilers Proline Promass 200 Coriolis flow measurement in efficient twowire technology for the chemical industry For the highest operational safety around the clock Efficient two-wire technology
More informationbetter measurement Simply a question of
Simply a question of better measurement SCHMIDT Flow Sensor SS 20.600 The powerful industrial professional for demanding applications involving air and gases. Industrial processes Pneumatic technology
More informationEX-RECESSED CEILING LIGHT FITTINGS
EX-RECESSED CEILING LIGHT FITTINGS RLF/RLF-INOX 250 18-58 W / RLF/RLF-INOX 250... N 18-36 W Metallic design for Zone 1 and Zone 21 The RLF... explosion-protected recessed ceiling light fittings with electronic
More informationFlow Measurement SITRANS F X
Overview Using a vortex flowmeter with integrated pressure and temperature compensation such as the allows you not only to lower installation costs but also increase the measuring accuracy of the measuring
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-10
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well
More informationIDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05
IDL0 Battery Powered Precision Digital Gauge for Leak Testing Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger
More informationGripping modules Pneumatic 2-finger parallel gripper Long-stroke gripper for small components Gripping force 120 N..
GM Sizes 85.. 205 Mass 0.48 kg.. 2.7 kg 120 N.. 595 N Stroke per finger 16 mm.. 30 mm Workpiece weight, force-fit gripping Up to 2.3 kg Application example 3 5 3 4 2 5 2 1 1 Pneumatic double pick & place
More informationElectropneumatic Positioner and Pneumatic Positioner Type 3760 JIS
Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. An electric standardized signal of 4 to 20 ma or
More informationFLAMMABLE GAS SENSOR/TRANSMITTER
FLAMMABLE GAS SENSOR/TRANSMITTER Plant safety protection for flammable gases. F E A T U R E S Fixed gas monitoring for point source hazards and perimeter protection in arduous duty and exposed locations.