1 Check Valves Cover headline Direct and pilot operated check valve functions for applications up to 5 bar (5 psi) and 7 L/min (6 USgpm) Cover subheadline EATON Screw-In Cartridge Valves E-VLSC-MC-E December 9 -.A

2 Check Valves Valve locator Functional Symbol Flow Typical Model Cavity Rating Pressure Page Check valve, direct L/min (USgpm) bar (psi) FPR/4 Inline () 5 (5) - FPR/8 Inline (8) 5 (5) - FPR/ Inline 45 () (457) - FPR/4 Inline 85 () (4) - FPR Inline 4 (7) 5 (6) - FPR/4 Inline (58) 5 (6) - FPR/ Inline (8) () - CA A879 4 () 5 (5) - CV-4 C () 5 (5) - CV-8 C-8- (8) 5 (5) - CV- C-- 76 () () -4 CV- C-- 76 () 5 (5) -4 CV- C-- (u) 4 () 5 (5) -6 CV-6 C-6-5 (4) () -7 CV-6 C-6-5 (4) 5 (5) -7 CV- C-- 7 (6) () -8 CA C-- (8) 5 (5) -9 Flow Typical Model Cavity Rating Pressure Page Check valve, direct L/min (USgpm) bar (psi) CV6- C-- 76 () 5 (5) -5 Flow Typical Model Cavity Rating Pressure Page Check valve, with bypass orifice L/min (USgpm) bar (psi) CV6- C-- 76 () 5 (5) - CV6-6 C-6-5 (4) () - Flow Typical Model Cavity Rating Pressure Page Check valve, pilot-to-open L/min (USgpm) bar (psi) SPC-8 C-8-9 (5) 4 (5) - SPC- C-- (6) 4 (5) - -.A EATON Screw-In Cartridge Valves E-VLSC-MC-E December 9

3 Check Valves (cont.) Valve locator Functional Symbol Flow Typical Model Cavity Rating Pressure Page Check valve, pilot-to-open L/min (USgpm) bar (psi) 4CK A66 (8) 5 (5) -4 4CK9 A6 9 (4) 5 (5) -5 4CKD9 A6 9 (4) 4 (6) -6 4CK A877 () 5 (5) -7 4CK A695 (8) 5 (5) -8 4SK A9-TA (8) 5 (5) - 4SK9 A9-TA 9 (4) 5 (5) - 4SK4 A94-T7A 4 (7) 5 (5) - 4KD5 Inline 5 (6) 7 () -5 Flow Typical Model Cavity Rating Pressure Page Dual pilot checks L/min (USgpm) bar (psi) DPC-8 C (5) 4 (5) - 4 Flow Typical Model Cavity Rating Pressure Page Dual pilot checks with thermal relief L/min (USgpm) bar (psi) 4CKKT5 A744 5 (6.6) (45) -4 4 Flow Typical Model Cavity Rating Pressure Page Check valve, pilot-to-close L/min (USgpm) bar (psi) 5CK A66 (8) 5 (5) -6 5CK A877 () 5 (5) -7 5CK A695 5 (65) 5 (5) -8 Flow Typical Model Cavity Rating Pressure Page Shuttle L/min (USgpm) bar (psi) SH A697 (5) 5 (5) -9 DSV- C-- (6) () -4 DSV-4 C-4- (.75) 4 (5) -4 DSV-8 C-8- (6) 4 (5) -4 DSV-XX-B Inline 7 (45) 5 (5) -4 EATON Screw-In Cartridge Valves E-VLSC-MC-E December 9 -.A

4 Check Valves Section Overview This section gives basic specifications for the full line of Eaton screw-in cartridge check valves. Its purpose is to provide a quick, convenient reference tool when choosing Vickers cartridge valves or designing a system using these components. Eaton's Integrated Hydraulics range of direct and pilot operated check valves provides the hydraulic circuit designer with a wide selection of cartridge and in-line products. Two pressure ratings are shown for all products featured in this catalog. The typical application pressure rating is the maximum recommended operating pressure for the valve in a given system. The fatigue pressure rating is the pressure for the valve to be free for infinite life from metal fatigue. All poppet type check valve cartridges have hardened and ground poppets and sharpedged ground steel seats. This provides an excellent product that is dirt-tolerant, has reliable seating, and is suitable for fast cycling with long life. Direct Operated Check Valves Cartridges fit into industry standard cavities and may be supplied for installation in manifolds, or be provided in standard housings having SAE or BSPP ports suitable for in-line mounting. A wide selection of cracking pressures is available from, to,7 bar ( to psi). Thus the opportunity exists to use the valves not only as conventional check but also as low pressure relief valves. Pilot Operated Check Valves These valves are used for: Position load locking As an alternative to counterbalance valves where neither the overrunning loads or release speed are factors in the application. The high pressure POC*- and POC*- series of pilot-to-open check valves complement the CE overcenter valves. The POC s provide a low cost alternative to load control when the dynamics of neither overrunning loads nor load release speed are factors to be considered in the design of the hydraulic circuit for the load to be controlled. The pilot-to-open valves positively lock a load from port to port until pilot pressure applied to port is sufficient to unseat the valve. This then permits flow from port to port. The load can also be released through means of an optional screw type override The POC*- covers flow up to 6 L/min (5 USgpm). The POC*- covers flow up to 4 L/min ( USgpm). With infinite life qualification to a fatigue pressure rating of bar (45 psi), these POC valves are suitable for use in a broad range of load control applications with typical system operating pressures up to 5 bar (5 psi). Tailoring of the circuit to gain energy savings while minimizing shock is obtained through the use of several standard cracking pressure ranges from, bar ( psi) to 7 bar ( psi). When anti-cavitation protection is required, the, bar (5 psi) spring should be used. For those applications where pilot pressure may not always be available, the valve can be ordered with an optional adjustable override. Features And Benefits Products in this catalog have been fatigue tested for one million cycles at % or million cycles at 5% of rated pressure. Simple load holding device. Low cost alternative to more complex solutions when overrunning loads are not present and / or control of load release speed is not required. Provides high operational efficiency and low spring settings. Valves are offered with a wide variety of standard housings with SAE and BSPP port options in the following configurations: In-line single In-line dual SAE, 4-bolt, code 6 Close coupled, nipple mounted asket mounted single asket mounted dual The Eaton range of direct and pilot operated check valves provides the hydraulic circuit designer with a wide selection of cartridge and in-line products. These valves can also be used in a C S or C S cavity. Four standard cracking pressures permit energy savings, while tailoring the hydraulic system requirements to minimize shock. Unique dual spring design provides high operational efficiency and a low pressure spring option for effective anti-cavitation protection. Unique design provides compact package and low pressure drops that match or exceed current market expectations and provide for excellent repeatability and stability. : pilot ratio satisfies simple load holding application requirements, while providing smooth operation and longer operating life. Optional adjustable override releases the load for situations where pilot pressure is not always available. Single pilot check Also offered are SPC-8 and SPC- single pilot check valves with pressures to 4 bar (5 psi) and flows to L/min (6 USgpm). These valves operate similar to the POC product but offer an opposite flow path which offers the designer a choice of pilot operated check valve when laying out a custom manifold for ease of design. Supporting products Integrated Hydraulics screw in cartridge valves are available in a wide range of mounting configurations and porting options to provide flexibility in developing circuits. Housings are available in either aluminum bar ( psi) or steel 5 bar (5 psi) configurations. All are available with a choice of BSPP (ISO 8/) or SAE style ports. -4.A EATON Screw-In Cartridge Valves E-VLSC-MC-E December 9

5 - Additional products, product lines, and services offered by Eaton - More Whether they re original equipment or genuine remanufactured components, high performance hydraulic pumps and motors from Eaton deliver the functionality and durability you need to keep working. Industry leading vane, piston, gear and geroter pumps and motors from Vickers, Eaton, Char-Lynn and Hydrokraft offer you hydraulic power components that are built tough for demanding industrial applications because uptime is critical in your busy world. For more information, visit EATON Screw-In Cartridge Valves E-VLSC-MC-E December 9-5.A

6 FPR - Check Valve uided Poppet Line Mounted Up to L/min (8 USgpm) Up to 5 bar (5 psi) Sectional View Operation These are in line check valves. Free flow is allowed from port to port when the inlet pressure rises higher than the crack pressure. Flow is prevented between port and port by the poppet resting on the seat within the body. Features All steel construction with hardened and precision ground poppet gives excellent flow capability and shut-off characteristics with good tolerance to particle (dirt) contaminated fluid. Inlet () Performance Data Description Outlet () A range of line mounted valves for convenient installation into hydraulic circuits. Valves allow flow at a low pressure drop (from.5 bar, 7 psi) in the free flow direction and prevent flow in the reverse direction. The range extends from /4 BSP to / BSP ( liters/min US PM to min/min, 8 US PM) nominal flow with cracking pressures from.5 to 5 bar (7 to 7.5 psi). Ratings and Specifications Figures based on: Oil Temp = 4 C Viscosity = cst (5 SUS) Rated flow L/min (8 USgpm) Valve material Working parts hardened and ground steel. External surfaces zinc plated. Mounting position Line mounted Weight FPR /4. kg (.4 lbs) FPR.89 kg (.95 lbs) FPR /8.9 kg (.4 lbs) FPR /4.75 kg (.85 lbs) FPR /.5 kg (.55 lbs) FPR /. kg (4.6 lbs) FPR /4.5 kg (. lbs) Recommended Filtration level BS554/4 Class 8/ (5 micron nominal) Operating Temp - C to +9 C (- C to +94 F) Nominal Viscosity Range 5 to 5 cst Pressure Drop FPR /4" Flow - L/min FPR /8" bar Pressure - psi FPR /" Flow - L/min FPR /4" bar Pressure - psi 4.5 bar bar Flow - US gpm 8 4 bar.5 bar Flow - US gpm Pressure - bar Pressure - bar Pressure - psi Pressure - psi Flow - L/min bar bar bar Flow - US gpm Flow - L/min bar bar.5 bar Flow - US gpm Pressure - bar Pressure - bar -.A EATON Screw-In Cartridge Valves E-VLSC-MC-E December 9

7 FPR - Check Valve uided Poppet Line Mounted Up to L/min (8 USgpm) Up to 5 bar (5 psi) Model Code FPR **.5 Cracking Pressure FPR/4 - Inline valve FPR/8 - Inline valve FPR/ - Inline valve FPR/4 - Inline valve FPR - Inline valve FPR/4 - Inline valve FPR/ - Inline valve bar (standard). -. bar (FPR/4, /8, /, /4 Only) bar bar. -. bar Pressure Drop FPR " Pressure - psi Flow - L/min bar bar.5 bar 6 9 Flow - US gpm Pressure - bar Pressure - psi Flow - L/min bar bar bar Flow - US gpm Pressure - bar FPR /" Flow - L/min bar 7.5 Pressure - psi bar.5 bar Flow - US gpm Pressure - bar A B C Flow Rate Pressure A B C FPR /4 L/min ( USgpm) 5 bar (5 psi) 6 9 /4" BSP FPR /8 L/min (8 USgpm) 5 bar (5 psi) 68 4 /8" BSP FPR / 45 L/min ( USgpm) bar (457 psi) 78 7 /" BSP FPR /4 85 L/min ( USgpm) bar (4 psi) 88 6 /4" BSP FPR 4 L/min (7 USgpm) 5 bar (6 psi) 46 " BSP FPR /4 L/min (58 USgpm) 5 bar (6 psi) 4 55 /4" BSP FPR / L/min (8 USgpm) bar ( psi) 55 6 /" BSP EATON Screw-In Cartridge Valves E-VLSC-MC-E December 9 -.A

8 CA - Check Valve Direct acting, ball type 4 L/min ( USgpm) 5 bar (5 psi) Sectional View Operation The valve remains closed until the spring bias is reached at port at which time the poppet lifts of the seat and allows flow from port to port. in the other direction the valve is closed. Features Cartridge design with machined seats and precision ground balls gives excellent flow reseat characteristics. Installation into the -port 7/8" UNF cavity gives easy fitment and serviceability. Performance Data Outlet () Description Inlet () These cartridge check valves allow flow at a low pressure drop, with cracking pressure from.5 to 7 bar (7 to psi) in the free flow direction and close to prevent flow in the reverse direction. They fit into simply machined cavities and are therefore ideal for installation into custom designed Hydraulic Integrated Circuits, manifold blocks and other hydraulic equipment. Ratings and Specifications Figures based on oil temperature of 4 C and viscosity of cst (5 SUS) Rated flow 4 L/min ( USgpm Maximum pressure 5 bar (5 psi) Cracking pressures.5 bar (7 psi).5 bar ( psi).5 bar (5 psi) 7. bar ( psi) Cartridge material All steel construction. External parts electroless zinc plated. Standard housing material Standard aluminum (up to bar). Add suffix "77" for steel option. Mounting position Unrestricted Cavity number A879 (See Section M) Torque cartridge into cavity 45 Nm ( lbs. ft.) Weight.5 kg (. lbs.) Seal kit number SK96 (Nitrile), SK96V (Viton ) Recommended filtration level BS554/4 Class 8/ (5 micron nominal) Operating temperature - C to +9 C (- C to +94 F) Leakage. ml/min nominal Nominal viscosity range 5 to 5 cst Viton is a registered trademark of E. I. DuPont Pressure Drop Curves Flow - L/min Pressure - psi bar 5 5 Pressure - bar Flow - US gpm -.A EATON Screw-In Cartridge Valves E-VLSC-MC-E December 9

9 CA - Check Valve Direct acting, ball type 4 L/min ( USgpm) 5 bar (5 psi) Model Code CA** W.5 S 4 CA - Cartridge only CA5 - Cartridge and body Port Size Code Port Size Housing Number - Body Only Aluminium Steel W /4" BSP A485 W /8" BSP A4 A475 6T /8" SAE A5676 A484 S Cracking Pressure bar (7 psi) bar ( psi) bar (5 psi) bar ( psi) 4 Seals - Nitrile (For use with most industrial hydraulic oils) SV - Viton (for high temperature and most special fluid applications) Dimensions mm (inch) Cartridge Only Single Valve /4", /8" Ports CA5 6.5 (.6) max. A/F. (.) 6. (.6) 5. (.97) 44. (.7) /4-6 UNF-A holes Ø6.8 (.7) thro.7 (.5) 8.8 (.) 5.9 (.6).8 (.5) 8. (.) Outlet () 44.8 (.76) 5.8 (.) Note: For applications above please consult our technical department or use the steel body option. Inlet () EATON Screw-In Cartridge Valves E-VLSC-MC-E December 9 -.A

10 CV-4 - Check Valve Direct acting, ball type 7.6 L/min ( USgpm) 5 bar (5 psi) Sectional View Operation The valve remains closed until the spring bias is reached at port at which time the poppet lifts of the seat and allows flow from port to port. in the other direction the valve is closed. Features Compact screw in cartridge design. Hardened steel ball to limit leakage and extend service life. Performance Data Descriptions This is a compact ball type check valve ideal for use in manifolds for load sense or low flow applications. 9 Ratings and Specifications Performance data is typical with fluid at,8 cst (5 SUS) and 49 C ( F) Typical application pressure (all ports) 5 bar (5 psi) Cartridge fatigue pressure (infinite life) 5 bar (5 psi) Rated flow 7.6 L/min ( USgpm) Free flow cracking L/min (.5 USgpm) bar (5 psi) Internal leakage, port to 5 drops/min bar ( psi) Temperature range 4 to C ( 4 to 48 F) Cavity C-4- Fluids All general purpose hydraulic fluids such as MIL - H-566, SAE, SAE, etc. Filtration Cleanliness code 8/6/ Weight: cartridge only.4 kg (.9 lbs.) Seal kit (Buna-N) (Viton ) Viton is a registered trademark of E. I. DuPont Pressure Drop 4 Pressure vs. Flow - L/min (,8 cst 49 F) Pressure Drop - psi 4 7 Pressure Drop - bar.5.5 Flow - USgpm (5 SUS F).5 -.A EATON Screw-In Cartridge Valves E-VLSC-MC-E December 9

11 CV-4 - Check Valve Direct acting, ball type 7.6 L/min ( USgpm) 5 bar (5 psi) Model Code CV 4 (V) B *** ** Function CV - Check valve Size 4-4 size Seal Material Blank - Buna-N V - Viton 4 Style B - Ball type 5 Port Size - Cartridge only 6 Free Flow Cracking Pressure 5 -,4 bar (5 psi) 7 Special Features - None (Only required if valve has special features, omitted if "") Dimensions mm (inch) Cartridge Only CV-4 9/6" HEX,7 (.5) 7/6 - UNF - A,8 (.859) Ø 8,64 (.4) Note: Torque cartridge in aluminum or steel housing to Nm (6- ft. lbs). WARNIN Aluminum housings can be used for pressures up to bar ( psi). Steel housings must be used for operating pressures above bar ( psi). EATON Screw-In Cartridge Valves E-VLSC-MC-E December 9 -.A

12 CV-8 - Check Valve Direct acting, poppet type L/min (8 USgpm) 5 bar (5 psi) Operation The valve remains closed until the spring bias is reached at port at which time the poppet lifts of the seat and allows flow from port to port. in the other direction the valve is closed. Features Compact screw in cartridge design. Hardened steel ball to limit leakage and extend service life. Sectional View Performance Data Description This is a compact poppet type check valve ideal for use in manifolds for load sense or low flow applications. Ratings and Specifications Performance data is typical with fluid at,8 cst (5 SUS) and 49 C ( F) Typical application pressure (all ports) 5 bar (5 psi) Cartridge fatigue pressure (infinite life) 8 bar (4 psi) Rated flow L/min (8 USgpm) Cracking L/min (.5 USgpm) bar (4 psi) -.7 bar ( psi) 5 -. bar (5 psi) bar (5 psi) -.7 bar ( psi) 6-4. bar (6 psi) Internal leakage 5 drops/min. 5 bar (5 psi) Temperature range 4 to C ( 4 to 48 F) Cavity C-8- Fluids All general purpose hydraulic fluids such as: MIL - H-566, SAE, SAE, etc. Filtration Cleanliness code 8/6/ Standard housing materials Aluminum or steel Weight: cartridge only.4 kg (.9 lbs.) Seal kit (Buna-N) (Viton ) Viton is a registered trademark of E.I. DuPont Pressure Drop 5 Flow - L/min (,8 cst 49 C) 4 Pressure Drop - psi A B C D Pressure Drop - bar Flow - USgpm (5 SUS F) A CV-8-P-O-6 B CV-8-P-O-5 C CV-8-P-O- D CV-8-P-O-4 -.A EATON Screw-In Cartridge Valves E-VLSC-MC-E December 9

13 CV-8 - Check Valve Direct acting, poppet type L/min (8 USgpm) 5 bar (5 psi) Model Code CV 8 (V) P (*) ** *** Function CV - Check valve Size 8-8 size Seal Material Blank - Buna-N V - Viton 4 Style P - Poppet 5 Valve Housing Material Omit for cartridge only A - Aluminum S - Steel 6 Port Size Code Port Size Housing Number Cartridge only Aluminum Fatigue rated Steel Fatigue rated 4T SAE T SAE T SAE /4 BSPP /8 BSPP See section J for housing details. 7 Cracking Pressure bar (4 psi) -.7 bar ( psi) 5 -. bar (5 psi) bar (5 psi) -.7 bar ( psi) 6-4. bar (6 psi) 8 Special features - None (Only required if valve has special features, omitted if "") SS - 6 Stainless Steel external components Dimensions mm (inch) Cartridge Only CV-8, (.87) hex 8,6 (.4) Installation Drawing (Steel) 9. (.6) 5.5 (.6).75" 6 Thd. 7,8 (.9) 8. (.5) 5.8 (.).4 (.) 44. (.7) 5.8 (.) X 7. (.8) 9. (.75) Ø,6 (.497) Note: Torque cartridge in aluminum or steel housing to 4-4 Nm (5- ft. lbs). WARNIN Aluminum housings can be used for pressures up to bar ( psi). Steel housings must be used for operating pressures above bar ( psi). EATON Screw-In Cartridge Valves E-VLSC-MC-E December 9 -.A

14 CV-/CV- - Check Valve Direct acting, poppet type Up to 76 L/min ( USgpm) 5 bar (5 psi) Operation The valve remains closed until the spring bias is reached at port at which time the poppet lifts of the seat and allows flow from port to port. in the other direction the valve is closed. Features Hardened and ground working parts to limit leakage and extend service life. Sectional View Performance Data Ratings and Specifications Description This is a compact poppet type check valve ideal for use in manifolds for load sense or low flow applications. Performance data is typical with fluid at,8 cst (5 SUS) and 49 C ( F) Typical application pressure (all ports) CV/CV bar ( psi)/5 bar (5 psi) Cartridge fatigue pressure (infinite life) CV/CV bar ( psi)/5 bar (5 psi) Rated flow 76 L/min ( USgpm) Free flow cracking L/min (.5 USgpm) -. bar ( psi) -.69 bar ( psi) -.8 bar ( psi) bar (5 psi) bar (4 psi) bar (65 psi) bar ( psi) bar (8 psi) bar ( psi) Internal leakage, Port to 5 drops/min. 5 bar (5 psi) Temperature range 4 to C ( 4 to 48 F) Cavity C-- Fluids All general purpose hydraulic fluids such as MIL - H-566, SAE, SAE, etc. Filtration Cleanliness code 8/6/ Standard housing material Aluminum or steel Weight: cartridge only.8 kg (.7 lbs.) Seal kit 5658 (Buna-N) (Viton ) Viton is a registered trademark of E.I. DuPont Pressure Drop Flow - L/min (,8 cst 49 C) Pressure Drop - psi A B C 5 5 Pressure Drop - bar Flow - USgpm (5 SUS F) A CV(*) *P B CV(*) *P 4 C CV(*) *P -4.A EATON Screw-In Cartridge Valves E-VLSC-MC-E December 9

15 CV-/CV- - Check Valve Direct acting, poppet type Up to 76 L/min ( USgpm) 5 bar (5 psi) Model Code CV(*) * P * ** *** Function CV - Check valve bar ( psi) CV - Check valve 5 bar (5 psi) Size - size Seal Material N - Buna-N V - Viton 4 Style P - Poppet 6 Port Size Code Port Size Housing Number Cartridge only Aluminum Aluminum Steel Light Duty Fatigue Rated Fatigue Rated B /8 BSPP T SAE T SAE 8-75 /4 BSPP /8 BSPP H SAE H SAE See section J for housing details. 5 Valve Housing Material - None A - Aluminum S - Steel 7 Free Flow Cracking Pressure -. bar ( psi) (anticavitation) -.69 bar ( psi) (anticavitation) -,8 bar ( psi) 5 -,4 bar (5 psi) 4 -,76 bar (4 psi) 65-4,48 bar (65 psi) - 6,9 bar ( psi) 8 -,4 bar (8 psi) bar ( psi) 8 Special Features - None (Only required if valve has special features, omitted if "") SS - 6 Stainless Steel external components Dimensions mm (inch) Cartridge Only CV- 5,4 (.) hex.875" 4 Thd. Torque cartridge in aluminum housing Nm (5-4 ft. lbs).torque cartridge in steel housing 68-7 Nm (5-55 ft. lbs) A - 8- Nm (8-9 ft. lbs) 8, (.) S Nm (- ft. lbs). Installation Drawing (Steel) 6.5 (.5) 8. (.) 5.8 (.) X Ø 7.4 (.8) 9 (.75),7 (.5) Ø 5,8 (.6) (.7) (.75) (.87) (.75) (.5) WARNIN Aluminum housings can be used for pressures up to bar ( psi). Steel housings must be used for operating pressures above bar ( psi). EATON Screw-In Cartridge Valves E-VLSC-MC-E December 9-4.A

16 CV6- - Check Valve Direct acting, poppet types, side in, nose out 76 L/min ( USgpm) 5 bar (5 psi) Operation The valve remains closed until the spring bias is reached at port at which time the poppet lifts of the seat and allows flow from port to port. in the other direction the valve is closed. Features Hardened and ground working parts to limit leakage and extend service life. Robust design with a 5 bar max pressure rating. Sectional View Performance Data Ratings and Specifications Description This is a poppet type screwin cartridge valve allowing free flow from port to. This gives flexibility to the manifold designer allowing the production of the most compact solution Performance data is typical with fluid at,8 cst (5 SUS) and 49 C ( F) Typical application pressure (all ports) 5 bar (5 psi) Cartridge fatigue pressure (infinite life) bar (45 psi) Rated flow 76 L/min ( USgpm) Free flow cracking L/min (.5 USgpm) bar (5 psi) 5 -. bar (5 psi) bar (5 psi) bar (5 psi) Internal leakage, Port to 5 drops/min. 5 bar (5 psi) Temperature range 4 to C ( 4 to 48 F) Cavity C-- Fluids All general purpose hydraulic fluids such as MIL - H-566, SAE, SAE, etc. Filtration Cleanliness code 8/6/ Standard housing materials Aluminum or steel Weight, cartridge only.8 kg (.7 lbs.) Seal kit 5658 (Buna-N) (Viton ) Viton is a registered trademark of E.I. DuPont Pressure Drop Flow - L/min (,8 cst 49 C) Pressure Drop - psi A B C 6 Pressure Drop - bar D Flow - USgpm (5 SUS F) A CV6--P-O-5 B CV6--P-O-5 C CV6--P-O-5 D CV6--P-O-5-5.A EATON Screw-In Cartridge Valves E-VLSC-MC-E December 9

17 CV6- - Check Valve Direct acting, poppet types, side in, nose out 76 L/min ( USgpm) 5 bar (5 psi) Model Code CV6 (*) P (*) ** *** Function CV6 - Check valve Size - size Seal Material Blank - Buna-N V - Viton 4 Style P - Poppet 5 Valve Housing Material Omit for cartridge only A - Aluminum S - Steel 6 Port Size Code Port Size Housing Number Cartridge only 7 Free Flow Cracking Pressure bar (5 psi) (Anti-cavitation) 5 -. bar (5 psi) bar (5 psi) bar (5 psi) Aluminum Aluminum Steel Light Duty Fatigue Rated Fatigue Rated B /8" BSPP T SAE T SAE 8-75 /4 BSPP /8 BSPP H SAE H SAE See section J for housing details. 8 Special Features - None (Only required if valve has special features, omitted if "") SS - 6 Stainless Steel external components Dimensions mm (inch) Note: Torque cartridge in housing A Nm (5-4 ft. lbs) S Nm (5-55 ft. lbs) Cartridge Only CV- 5,4 (.) hex.875" 4 Thd. 8, (.) Installation Drawing (Steel) 6.5 (.5) 8. (.) 5.8 (.) X Ø 7.4 (.8) 9 (.75),7 (.5) (.7) (.75) (.87) (.75) (.5) Ø 5,8 (.6) WARNIN The cavity should be machined to 4,9 (.56) maximum diameter and 6, (.47) maximum depth (see cavity detail, page M-) WARNIN Aluminum housings can be used for pressures up to bar ( psi). Steel housings must be used for operating pressures above bar ( psi). EATON Screw-In Cartridge Valves E-VLSC-MC-E December 9-5.A

18 CV- - Check Valve Direct acting, poppet type 4 L/min ( USgpm) 5 bar (5 psi) Operation The valve remains closed until the spring bias is reached at port at which time the poppet lifts of the seat and allows flow from port to port. in the other direction the valve is closed. Pilot Operation Hardened and ground working parts to limit leakage and extend service life. Robust design with a 5 bar max pressure rating. Sectional View Performance Data Ratings and Specifications Performance data is typical with fluid at,8 cst (5 SUS) and 49 C ( F) Typical application pressure (all ports) 5 bar (5 psi) Cartridge fatigue pressure (infinite life) 5 bar (5 psi) Rated flow 4 L/min ( USgpm) Free flow cracking L/min (.5 USgpm) bar (.5 psi) bar (5 psi) bar ( psi). -.8 bar ( psi) 4. -,76 bar (4 psi) ,5 bar (8 psi) 6. -, bar (6 psi) Internal leakage, Port to 5 drops/min. 5 bar (5 psi) Hysteresis Less than,5 bar (5 psi) Temperature range 4 to C ( 4 to 48 F) Cavity C-- or C--U Fluids All general purpose hydraulic fluids such as MIL - H-566, SAE, SAE, etc. Filtration Cleanliness code 8/6/ Standard housing materials Aluminum or steel Weight, cartridge only,4 kg (.54 lbs.) Seal kit (Buna-N) (Viton ) Viton is a registered trademark of E.I. DuPont Description This is a poppet type, direct acting screw-in cartridge check valve allowing free flow from port to. Pressure Drop Pressure Drop - psi Flow - L/min (,8 cst 49 C) 4 A B C Flow - USgpm (5 SUS F) Pressure Drop - bar A CV--P-O-8 B CV--P-O- C CV--P-O-.5-6.A EATON Screw-In Cartridge Valves E-VLSC-MC-E December 9

19 CV- - Check Valve Direct acting, poppet type 4 L/min ( USgpm) 5 bar (5 psi) Model Code CV (V) P (*) *** (U) ** Function CV - Check valve Size - size Seal Material Blank - Buna-N V - Viton 4 Style P - Poppet 5 Valve Housing Material Omit for cartridge only A - Aluminum S - Steel 6 Port size Code Port Size Housing Number Cartridge only C--U C-- C--U C-- Aluminum Aluminum Steel Steel Light Duty Fatigue Rated Fatigue Rated Fatigued Rated T SAE T SAE /" BSPP /4 BSPP See section J for housing details. 7 Cavity Blank - Cavity without undercut U - Cavity with undercut 8 Cracking Pressure.5 -,7 bar (.55 psi) 5. -,5 bar 5 psi) -,69 bar ( psi) -,8 bar ( psi) 4 -,75 bar (4 psi) 8-5,5 bar (8 psi) 6 -, bar (6 psi) 9 Special Features - None (Only required if valve has special features, omitted if "") Dimensions mm (inch) Torque cartridge in housing A Nm (6-7 ft. lbs). S - -5 Nm (75-85 ft. lbs). Cartridge Only CV,6 (.5) hex Installation Drawing (Steel).7 (.5) 8.9 (.74) 8.7 (.).6" Thd. 8,9 (.75) (.5) (.5) X Ø. (.46) 44,7 (.76).7 (.5) 88.9 (.5) 6.5 (.5) 5.4 (.) 5.8 (.) Ø,75 (.95) WARNIN Aluminum housings can be used for pressures up to bar ( psi). Steel housings must be used for operating pressures above bar ( psi). EATON Screw-In Cartridge Valves E-VLSC-MC-E December 9-6.A

20 CV-6/CV-6 - Check Valve Direct acting, poppet type 5 L/min (4 USgpm) 5 bar (5 psi) Operation The valve remains closed until the spring bias is reached at port at which time the poppet lifts of the seat and allows flow from port to port. In the other direction the valve is closed. Features Hardened and ground working parts to limit leakage and extend service life. Sectional View CV-6 Performance Data Ratings and Specifications Performance data is typical with fluid at,8 cst (5 SUS) and 49 C ( F) Typical application pressure (all ports) CV-6 bar ( psi)/cv 5 bar (5 psi) Cartridge fatigue pressure (infinite life) CV-6 bar ( psi)/cv-6 5 bar (5 psi) Rated flow 5 L/min (4 USgpm) Free flow cracking L/min (.5 USgpm) 5 -,4 bar (5 psi) -,4 bar ( psi) -,7 bar ( psi) 4 -,67 bar (4 psi) 5 -,45 bar (5 psi) - 6,9 bar ( psi) Note: Only the 5 psi option is available for CV-6 Internal leakage, Port to 5 drops/min. bar ( psi) Temperature range 4 to C ( 4 to 48 F) Cavity C-6- Fluids All general purpose hydraulic fluids such as: MIL - H-566, SAE, SAE, etc. Filtration Cleanliness code 8/6/ Standard housing materials Aluminum or steel Weight, cartridge only,6 kg (.58 lbs.) Seal kit 5658 (Buna-N) (Viton ) Viton is a registered trademark of E.I. DuPont Description Pressure Drop This is a poppet type, direct acting screw-in cartridge check valve allowing free flow from port to. Pressure Drop - psi B Flow - L/min (,8 cst 49 C) A Pressure Drop - bar D C 4 Flow - USgpm (5 SUS F) A CV(*)-6-P-O-5 B CV(*)-6-P-O- C CV(*)-6-P-O-5 D CV(*)-6-P-O-5-7.A EATON Screw-In Cartridge Valves E-VLSC-MC-E December 9

21 CV-6/CV-6 - Check Valve Direct acting, poppet type 5 L/min (4 USgpm) 5 bar (5 psi) Model Code CV(*) 6 (V) P *** ** Function CV - Check valve, bar CV - Check valve, 5 bar Size 6-6 size Seal Material Blank - Buna-N V - Viton 4 Style P - Poppet 5 Port Size Code Port Size Housing Number Cartridge only 6B /4" BSPP Aluminum Aluminum Steel Light Duty Fatigue Rated Fatigue Rated T SAE -754 T SAE /" BSPP /4 BSPP H SAE H SAE 566 See section J for housing details. 6 Cracking Pressure 5 -,4 bar (5 psi) (Anti-cavitation) -,4 bar ( psi) -.7 bar ( psi) bar (4 psi) bar (5 psi) bar ( psi) Only the 5 psi option is available for CV-6 7 Special Features - None (Only required if valve has special features, omitted if "") Dimensions mm (inch) Torque cartridge in housing A- 8- Nm (8-9 ft lbs) S Nm (- ft lbs) Cartridge Only Installation Drawing (Aluminum) CV, CV 8, (.5) hex, (.5).7 (.5) 8.4 (.)." Thd (.5) 6.5 (.5) 44,5 (.75). (.4) 68.8 (.688) 88.9 (.5) X 8.74 (.44).8 (.5) Ø 8,5 (.) WARNIN Aluminum housings can be used for pressures up to bar ( psi). Steel housings must be used for operating pressures above bar ( psi). EATON Screw-In Cartridge Valves E-VLSC-MC-E December 9-7.A

22 CV- - Check Valve Direct acting, poppet type 7 L/min (6 USgpm) bar ( psi) Operation This is a poppet type, direct acting screw-in cartridge check valve allowing free flow from port to. Features Hardened and ground working parts to limit leakage and extend service life. Robust design with a bar ( psi) max pressure rating. Sectional View Performance Data Ratings and Specifications Performance data is typical with fluid at,8 cst (5 SUS) and 49 C ( F) Typical application pressure (all ports) bar ( psi) Cartridge fatigue pressure (infinite life) bar ( psi) Rated flow 7 L/min (6 USgpm) Free flow cracking L/min (.5 USgpm) 5 -,4 bar (5 psi) 5 -, bar (5 psi) -,7 bar ( psi) 6-4,4 bar (6 psi) - 6,9 bar ( psi) Internal leakage, Port to 5 drops/min. bar ( psi) Temperature range 4 to C ( 4 to 48 F) Cavity C-- Fluids All general purpose hydraulic fluids such as MIL - H-566, SAE, SAE, etc. Filtration Cleanliness code 8/6/ Standard housing material Aluminum Weight, cartridge only,49 kg (.9 lbs.) Seal kit (Buna-N) (Viton ) Viton is a registered trademark of E.I. DuPont Description This is a poppet type, direct acting screw-in cartridge check valve allowing free flow from port to. Pressure Drop Flow - L/min (,8 cst 49 C) Pressure Drop - psi A 75 B 5 C Pressure Drop - bar 4 Flow - USgpm (5 SUS F) 5 6 A CV--P-O- B CV--P-O- C CV--P-O-5-8.A EATON Screw-In Cartridge Valves E-VLSC-MC-E December 9

23 CV- - Check Valve Direct acting, poppet type 7 L/min (6 USgpm) bar ( psi) Model Code CV (V) P *** *** Function CV - Check valve Size - size Seal Material Blank - Buna-N V - Viton 4 Style P - Poppet 5 Port Size Code Port Size Housing Number Aluminum Aluminum Light Duty Fatigue Rated Cartridge only 8B " BSPP T SAE /4" BSPP " BSPP H SAE H SAE Free Flow Cracking Pressure 5 -,4 bar (5 psi) Anti-cavitation 5 -, bar (5 psi) -,7 bar ( psi) 6-4,4 bar (6 psi) - 6,9 bar ( psi) 7 Special Features - None (Only required if valve has special features, omitted if "") Dimensions mm (inch) Note: Torque cartridge in aluminum housing 8-55 Nm (95-5 ft lbs) Cartridge Only CV Installation Drawing (Aluminum) 47,6 (.87) hex 4, (.55) 4. (.6).65" Thd. 76. (.).6 (4.) X 8.74 (.44) 6. (.4) 57, (.5). (.4) 8. (.9).6 (4.) Ø 6,44 (.45) EATON Screw-In Cartridge Valves E-VLSC-MC-E December 9-8.A

24 CA - Check Valve Direct acting, poppet style L/min (8 USgpm) 5 bar (5 psi) Operation This is a poppet type, direct acting screw-in cartridge check valve allowing free flow from port to. Features Hardened and ground working parts to limit leakage and extend service life. Rhobust design with a 5 bar (5 psi) max pressure rating. Sectional View Performance Data Ratings and Specifications Figures based on: Oil Temp = 4 C Viscosity = cst (5 SUS) Typical application pressure (all ports) Rated flow Free flow cracking pressure Leakage Temperature range 5 bar (5 psi) L/min (8 USgpm). - bar (4.4 psi). - bar (4.5 psi). - bar (9 psi) bar (58 psi) bar ( psi). millilitres/min nominal to 9 C ( to 94 F) Cavity A45 (C--) See Section M) Torque cartridge into cavity 5 Nm ( lbs ft) Filtration BS554/4 Class 8/ (5 micron nominal) Cartridge material All steel construction. External parts electroless zinc plated. Standard housing material Aluminum (up to bar) Add suffix 77 for steel option. Norminal Viscosity Range 5 to 5 cst Weight.48 kg (.6 lbs.) Mounting position Unrestricted Seal kit SK96 (Nitrile) SK96V (Viton ) Viton is a registered trademark of E.I. DuPont Descriptions This is a poppet type, dirct acting screw-in cartridge check valve allowing free flow from port to. Pressure Drop Pressure - psi 5 5 Flow - L/min S S.S.S S Flow - US gpm Pressure - bar -9.A EATON Screw-In Cartridge Valves E-VLSC-MC-E December 9

25 CA - Check Valve Direct acting, poppet style L/min (8 USgpm) 5 bar (5 psi) Model Code CA*** W. S Function CA - Cartridge only CA55 - Cartridge and body 4 Port Size - Bodied Valves Only Code Port Size Housing Number Aluminum Steel W /4" BSP C45 C46 T /4" SAE C4 C4 Cracking Pressure. -. bar (4.4 psi). -. bar (4.5 psi). -. bar (9 psi) bar (58 psi) bar ( psi) 4 Seals S - Nitrile (For use with most industrial hydraulic oils) SV - Viton (For high temperature and most special fluid applications) Dimensions mm (inch) Note: For applications above please consult our technical department or use the steel body option. Cartridge Only CA 46 A/F Single Valve /4", /" Ports CA55 5. (.98). (.6) 76. (.) 5. (.59) 65. (.56).6 (4.) 7.5 (.85). (.9) 4. (.57) 8. (.5).6 (4.) 8. (.5) EATON Screw-In Cartridge Valves E-VLSC-MC-E December 9-9.A

26 CV6- - Check Valve Direct acting, poppet type with orifice 76 L/min ( USgpm) 5 bar (5 psi) Operation Features The poppet remains on its seat until the pressure drop across the orifice overcomes the spring force over the seat area. Full flow will then take place from port to. Flow from port to will be restricted by the orifice. Hardened and ground working parts extend service life. Robust design with a 5 bar (5 psi) max pressure rating. Compact simple solution in a single cartridge. Sectional View Performance Data Ratings and Specifications Performance data is typical with fluid at,8 cst (5 SUS) and 49 C ( F) Typical application pressure (all ports) 5 bar (5 psi) Cartridge fatigue pressure (infinite life) 5 bar (5 psi) Rated flow 76 L/min ( USgpm) Free flow cracking L/min (.5 USgpm) -, bar ( psi) -,69 bar ( psi) -,8 bar ( psi) 5 -,4 bar (5 psi) 4 -,76 bar (4 psi) 65-4,48 bar (65 psi) - 6,9 bar ( psi) 8 -,4 bar (8 psi) - 4,5 bar ( psi) Orifice size range.5 to.5" ( mm) Temperature range 4 to C ( 4 to 48 F) Cavity C-- Fluids All general purpose hydraulic fluids such as MIL - H-566, SAE, SAE, etc. Filtration Cleanliness code 8/6/ Standard housing material Aluminum or steel Weight, cartridge only,49 kg (.9 lbs.) Seal kit (Buna-N) (Viton ) Viton is a registered trademark of E.I. DuPont Description This is a poppet type screw-in cartridge check valve with a by-pass orifice. This will allow free flow into an actuator while restricting the flow out of it Pressure Drop Pressure Drop - psi 5 4 Flow - L/min (,8 cst 49 C) A B C 5 5 Flow - USgpm (5 SUS F) Port to Pressure Drop - bar A CV6 *P B CV6 *P 4 C CV6 *P -.A EATON Screw-In Cartridge Valves E-VLSC-MC-E December 9

27 CV6- - Check Valve Direct acting, poppet type with orifice 76 L/min ( USgpm) 5 bar (5 psi) Model Code CV6 * P * *** *** *** Function CV6 - Check valve with bypass orifice Size - size Seal Material N - Buna-N V - Viton 4 Style P - Poppet 5 Valve Housing Material - No housing A - Aluminum S - Steel 6 Free Flow Cracking Pressure -, bar ( psi) (Anti-cavitation) -,69 bar ( psi) (Anti-cavitation) -,8 bar ( psi) 5 -,4 bar (5 psi) 4 -,76 bar (4 psi) 65-4,48 bar (65 psi) - 6,9 bar ( psi) 8 -,4 bar (8 psi) - 4,5 bar ( psi) 7 Port Size Code Port Size Housing Number Aluminum Aluminum Steel Light Duty Fatigue Rated Fatigue Rated B /8" BSPP T SAE T SAE 8-75 /4" BSPP /8" BSPP H SAE H SAE Orifice Size Specify in thousandths of an inch Ø -.5 max Ø -.5 min 9 Special Features - None (Only required if valve has special features, omitted if "") SS - 6 Stainless Steel external components Dimensions mm (inch) Torque cartridge in housing A Nm (5-4 ft lbs) S Nm (5-55 ft lbs). Cartridge Drawing Installation Drawing (Steel) CV6-8, (.) 8. (.) 9 (.75) 5,4 (.) hex 6.5 (.5) 5.8 (.) X Ø 7.4 (.8).875" 4 Thd.,7 (.5) (.7) (.75) (.87) (.75) (.5) Ø 5,8 (.6) EATON Screw-In Cartridge Valves E-VLSC-MC-E December 9 -.A

28 CV6-6 - Check Valve Direct acting, poppet type with orifice 5 L/min (4 USgpm) bar () psi Sectional View Operation The poppet remains on its seat until the pressure drop across the orifice overcomes the spring force over the seat area. Full flow will then take place from port to. Flow from port to will be restricted by the orifice. Features Hardened and ground working parts extend service life. Robust design with a bar ( psi) max pressure rating. Compact simple solution in a single cartridge. Performance Data Ratings and Specifications Description This is a poppet type screw-in cartridge check valve with a by-pass orifice. This will allow free flow into an actuator while restricting the flow out of it. Performance data is typical with fluid at,8 cst (5 SUS) and 49 C ( F) Typical application pressure (all ports) bar ( psi) Cartridge fatigue pressure (infinite life) bar ( psi) Rated flow 5 L/min (4 USgpm) Free flow cracking L/min (.5 USgpm) 5 -, bar ( psi) -,4 bar ( psi) -,7 bar ( psi) bar (4 psi) 5 -,45 bar (5 psi) bar ( psi) Orifice size range.5 to.5" ( mm) Temperature range 4 to C ( 4 to 48 F) Cavity C-6- Fluids All general purpose hydraulic fluids such as MIL - H-566, SAE, SAE, etc. Filtration Cleanliness code 8/6/ Standard housing material Aluminum Weight, cartridge only,6 kg (.58 lbs.) Seal kit 5658 (Buna-N) (Viton ) Viton is a registered trademark of E.I. DuPont Pressure Drop Pressure Drop - psi Flow - L/min (,8 cst 49 C) A B C Pressure Drop - bar A CV6 6*P 5 B CV6 6*P 4 Flow - USgpm (5 SUS F) Port to C CV6 6*P 5 -.A EATON Screw-In Cartridge Valves E-VLSC-MC-E December 9

29 CV6-6 - Check Valve Direct acting, poppet type with orifice 5 L/min (4 USgpm) bar () psi Model Code CV6 6 * P * *** *** *** Function CV6 - Check valve with bypass orifice Size 6-6 size Seal Material N - Buna-N V - Viton 4 Style P - Poppet 5 Valve Housing Material - No housing A - Aluminum 6 Port Size - Cartridge only 7 Free Flow Cracking Pressure 5 -,4 bar (5 psi) (Anti-cavitation) -,4 bar ( psi) (Anti-cavitation) -,7 bar ( psi) 4 -,76 bar (4 psi) 5 -,45 bar (5 psi) - 6,9 bar ( psi) Code Port Size Housing Number Aluminum Light Duty 6B /4" BSPP T SAE Aluminum Fatigue Rated 4 /" BSPP /4" BSPP H SAE H SAE Orifice Size Specify in thousandths of an inch Ø -.5 max Ø -.5 min 9 Special Features - None (Only required if valve has special features, omitted if "") Dimensions mm (inch) Note: Torque cartridge in aluminum housing 8- Nm (8-9 ft. lbs). Cartridge Drawing CV6-6,7.7 (.5).5" HEX Installation Drawing (.5) 8.4 (.)."- Thd. 44,58 (.75) 88.9 (.5). (.4) 6.5 (.5) 68.8 (.688) 88.9 (.5) X 8.74 (.44).8 (.5) Ø 8,5 (.) EATON Screw-In Cartridge Valves E-VLSC-MC-E December 9 -.A

30 SPC-8 - Check Valve Pilot-to-open, poppet type 9 L/min (5 USgpm) 4 bar (5 psi) Sectional View Operation Pressure on the valve port causes the poppet to lift against the spring force, allowing the flow to the cylinder port. Reverse flow is prevented by the poppet reseating. Performance Data Pressure applied to the pilot port will overcome the cylinder port pressure and lift the poppet from its seat, allowing flow from the cylinder to valve port. Features Hardened and ground poppet gives excellent flow capability for valve size, positive sealing and long working life. Cartridge construction allows installation in actuators, manifold blocks and Hydraulic Integrated Circuits. Fits the same cavity as the overcenter valves of a similar size. Ratings and Specifications Performance data is typical with fluid at,8 cst (5 SUS) and 49 C ( F) Typical application pressure (all ports) 4 bar (5 psi) Cartridge fatigue pressure (infinite life) 4 bar (5 psi) Rated flow 9 L/min (5 USgpm) Pilot ratio : Cracking pressure 5 -, bar (5 psi) 5 -,4 bar (5 psi) 65-4,5 bar (65 psi) Internal leakage (all leak 4 bar (5 psi) Port to Port to unsealed piston* *Unsealed piston only supplied with 5 psi spring option Temperature range Cavity Fluids 5 drops/min. maximum at 4 bar (5 psi) 4 cc/min. maximum, zero leakage with sealed piston 4 to C ( 4 to 48 F) C-8- All general purpose hydraulic fluids such as MIL - H-566, SAE, SAE, etc Recommended filtration Cleanliness code 8/6/ Standard housing materials Aluminum or steel Weight, cartridge only,7 kg (.5 lbs.) Seal kit -76 (Buna-N) -77 (Viton ) Viton is a registered trademark of E.I. DuPont Description Pilot check valves allow flow to pass in one direction, with a low pressure drop, then prevent reverse flow until pilot pressure is applied. There are many applications for this valve type, the most common being to lock and hold a cylinder, or another hydraulic actuator, in position. These valves are ideally suited for fitting directly into a cylinder, giving economy of installation, direct control of cylinder movement and ease of servicing. Pressure Drop Flow - L/min (,8 cst 49 C) Pressure Drop - psi A 6 B 8 C 4 D 4 5 Flow - USgpm (5 SUS F) Pressure Drop - bar A CV6 6*P 5 B CV6 6*P C CV6 6*P 5 -.A EATON Screw-In Cartridge Valves E-VLSC-MC-E December 9

31 SPC-8 - Check Valve Pilot-to-open, poppet type 9 L/min (5 USgpm) 4 bar (5 psi) Model Code SPC 8 (X) P (*) ** ** SPC - Single pilot check valve Size 8-8 size Seals Blank - Buna-N V - Viton U - Buna-N with no piston seals W - Viton with no piston seals 4 Style P - Poppet 5 Valve Body Material Omit for cartridge only A - Aluminum S - Steel 6 Port Size Code Port Size Housing Number Aluminum Fatigue Rated Steel Fatigue Rated 4T SAE T SAE /4" BSPP /8" BSPP Cracking Pressure 5 -, bar (5 psi) 5 -,4 bar (5 psi) 65-4,5 bar (65 psi) 8 Special Features - None (Only required if valve has special features, omitted if "") SS - 6 Stainless Steel external components Dimensions mm (inch) Note: Torque cartridge in aluminum or steel housing to 4-4 Nm (5- ft lbs). Cartridge Drawing Installation Drawing (Steel) SPC-8, (.87) hex.75" 6 Thd. 8,5 (.) 5.5 (.6) 7.4 (.8) 9. (.6) 54. (.) (.65) 9.7 (.7) 4,4 (.6) 9. (.75) -Slots. (.) 56.9 (.4) 6.5 (.5) 9. (.75) Ø 4, (.559) Ø 5,8 (.6) WARNIN Aluminum housings can be used for pressures up to bar ( psi). Steel housings must be used for operating pressures above bar ( psi). EATON Screw-In Cartridge Valves E-VLSC-MC-E December 9 -.A

32 SPC- - Check Valve Pilot-to-open, poppet type L/min (6 USgpm) 4 bar (5 psi) Sectional View Operation Pressure on the valve port causes the poppet to lift against the spring force, allowing the flow to the cylinder port. Reverse flow is prevented by the poppet reseating. Pressure applied to the pilot port will overcome the cylinder port pressure and lift the poppet from its seat, allowing flow from the cylinder to valve port. Features Hardened and ground poppet gives excellent flow capability for valve size, positive sealing and long working life. Cartridge construction allows installation in actuators, manifold blocks and Hydraulic Integrated Circuits. Fits the same cavity as the overcenter valves of a similar size. Performance Data Description Pilot check valves allow flow to pass in one direction, with a low pressure drop, then prevent reverse flow until pilot pressure is applied. There are many applications for this valve type, the most common being to lock and hold a cylinder, or another hydraulic actuator, in position. These valves are ideally suited for fitting directly into a cylinder, giving economy of installation, direct control of cylinder movement and ease of servicing. WARNIN Do not use Single Pilot Check Valves in load holding applications where either overrunning loads are possible or load release speed is critical. Failure to observe these guidelines may result in bodily injury or damage to equipment. Ratings and Specifications Performance data is typical with fluid at,8 cst (5 SUS) and 49 C ( F) Typical application pressure (all ports) 4 bar (5 psi) Cartridge fatigue pressure (infinite life) 4 bar (5 psi) Rated flow L/min (6 USgpm) Pilot ratio 4: Cracking L/min (.5 USgpm) 5 -,7 bar (5 psi) 5 -,45 bar (5 psi) - 6,9 bar ( psi) Internal leakage Port to 5 drops/min. maximum at bar ( psi) Temperature range 4 to C ( 4 to 48 F) Cavity C-- Fluids All general purpose hydraulic fluids such as MIL - H-566, SAE, SAE, etc. Filtration Cleanliness code 8/6/ Standard housing material Aluminum Weight, cartridge only,8 kg (.8 lbs.) Seal kit (check valve) -567 (Buna-N) (Viton ) Viton is a registered trademark of E.I. DuPont Pressure Drop Pressure Drop - psi Flow - L/min (,8 cst 49 C) A SPC--P-- B SPC--P--5 A B 4 6 Flow - USgpm (5 SUS F) C D C SPC--P--5 D - Port to (piloted open) Pressure Drop - bar -.A EATON Screw-In Cartridge Valves E-VLSC-MC-E December 9

33 SPC- - Check Valve Pilot-to-open, poppet type L/min (6 USgpm) 4 bar (5 psi) Model Code SPC (X) P ** *** Function SPC - Single pilot check valve Size - size Seal Material Blank - Buna-N V - Viton U - Buna-N with no piston seals W - Viton with no piston seals 4 Style P - Poppet 5 Port Size Code Port Size Housing Number Aluminum Aluminum Light Duty Fatigue Rated Cartridge only B /8" BSPP T SAE /4" BSPP /8" BSPP H SAE H SAE See section J for housing details. 6 Free Flow Cracking Pressure 5 -,7 bar (5 psi) 5 -,45 bar (5 psi) - 6,9 bar ( psi) 7 Special Features - None (Only required if valve has special features, omitted if "") SS - 6 Stainless Steel external components Dimensions mm (inch) Torque cartridge housing A Nm (5-4 ft. lbs). B Nm (5-55 ft. lbs) Cartridge Drawing SPC- 5,4 (.) hex 8, (.) Installation Drawing 4,6 (.97) 7.9 (.) Thd. 8,8 (.74) 57. (.5) X7,4 (.8) 4,8 (.7) 75,4 (.97) 46,8 (.84) 5 (.97) 9.5 (.8) 57.5 (.5) 75.4 (.97) 5,4 (.) Ø 5,8 (.6) Ø 7,4 (.684) WARNIN Aluminum housings can be used for pressures up to bar ( psi). Steel housings must be used for operating pressures above bar ( psi). EATON Screw-In Cartridge Valves E-VLSC-MC-E December 9 -.A

34 4CK - Check Valve Pilot-to-open, poppet type L/min (8 USgpm) 5 Bar (5 psi) Operation Pressure on the valve port causes the poppet to lift against the spring force, allowing the flow to the cylinder port. Reverse flow is prevented by the poppet reseating. Pressure applied to the pilot port will overcome the cylinder port pressure and lift the poppet from its seat, allowing flow from the cylinder to valve port. Features Hardened and ground poppet gives excellent flow capability for valve size, positive sealing and long working life. Cartridge construction allows installation in actuators, manifold blocks and Hydraulic Integrated Circuits. Fits the same cavity as the overcenter valves of a similar size. Sectional View Performance Data Ratings and Specifications Pilot () Valve () Cyl () Figures based on: Oil Temp = 4 C Viscosity = cst (5 SUS) Rated flow L/min (8 USgpm) Max setting 5 bar (5 psi) Pilot ratio : Cartridge material Working parts hardened & ground steel. Electroless zinc plated body. Standard housing material Standard aluminium (up to bar) Add suffix 77 for steel option Mounting position Unrestricted Cavity number A66 (See section M) Torque cartridge into cavity 45 Nm ( lbs ft) Weight 4CK.8 kg (.8 lbs) 4CK5.4 kg (.75 lbs) 4CKK5.76 kg (.67 lbs) Seal kit number SK4 (Nitrile) SK4V (Viton ) Recommended filtration level BS554/4 Class 8/ (5 micron nominal) Operating temperature - C to +9 C (- to +94 F) Leakage. milliliters/min nominal (5 dpm) Nominal viscosity range 5 to 5 cst Viton is a registered trademark of E.I. DuPont Description Pilot check valves allow flow to pass in one direction, with a low pressure drop, then prevent reverse flow until pilot pressure is applied. There are many applications for this valve type, the most common being to lock and hold a cylinder, or another hydraulic actuator, in position. These valves are ideally suited for fitting directly into a cylinder, giving economy of installation, direct control of cylinder movement and ease of servicing. Pressure Drop Pressurep - psi Flow - L/min 4 5 Free flow Piloted open Flow - US gpm Pressure - bar -4.A EATON Screw-In Cartridge Valves E-VLSC-MC-E December 9

Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm)

Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm) Vickers Cartridge Valves Load Controls Screw In Cartridge Valves Pressures to 50 bar (5000 psi) Flows to 90 l/min (50 USgpm) Rev. 2/99 722 Contents MODEL DESCRIPTION TYP. APPLICATION PRESSURE bar (psi)

More information

Pressure control. Direct and pilot operated pressure control valves for applications up to 350 bar (5000 psi) and 300 L/min (80 USgpm)

Pressure control. Direct and pilot operated pressure control valves for applications up to 350 bar (5000 psi) and 300 L/min (80 USgpm) Hydraulic Screw-in Cartridge Valves (SiCV) Pressure control Direct and pilot operated pressure control valves for applications up to 5 bar (5 psi) and L/min (8 USgpm) Pressure control PRSSUR CONTROLS...-4

More information

Motion Controls Valve locator

Motion Controls Valve locator Motion Controls Valve locator unctional Symbol C C Model Cavity low Rating Typical Pressure Page OCV standard L/min (USgpm) bar (psi) CE A9 (5) 7 (4) - CE A66 (8) 7 (4) - CEH A66 (8) 5 (5) - CE9 A6 9 ()

More information

Logic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm)

Logic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm) Vickers artridge Valves Logic Elements Screw-in artridge Valves Pressures to 9 bar ( psi) Flows to l/min (8 USgpm) Revised 9/98 7 ontents MODEL DESRIPTION TYPIL PPLITION PRESSURE bar (psi) RTED FLOW l/min

More information

Pilot Operated Check Valves Catalog Quick Reference

Pilot Operated Check Valves Catalog Quick Reference Quick Reference Pilot to Open Model No. Description Flow* Pressure Page RPC NCS/3 Pilot Operated Check Valve, Pilot to Open.5 l/min [5. US gal/min] RPC NCS/3 35 l/min [9.3 US gal/min] CP5- SDC-3 3 l/min

More information

Cartridge Valves Technical Information. Pilot operated check valves. Quick reference

Cartridge Valves Technical Information. Pilot operated check valves. Quick reference Quick reference Pilot to Open Model No. Description Flow* Pressure Page P RPC 4 NCS4/ Pilot Operated Check Valve, Pilot to Open l/min [ US gal/min] RPC 6 NCS6/ 5 l/min [7 US gal/min] CP45- SDC- l/min RPC

More information

PRESSURE COMPENSATORS TECNORD

PRESSURE COMPENSATORS TECNORD PRESSURE COMPENSATORS 2-way, Compensating / Reducing Valves GPM PSI LPM BAR MODEL CAVITY PAGE 8 3500 30 245 DF-CP2 7/8 14 UNF 60 16 3500 60 245 QC-CP2 Special 62 Typical Schematic Typical application for

More information

CV08-20 Check Valve DIRECTIONAL VALVES. DESCRIPTION A screw-in, cartridge-style, hydraulic check valve for use as a blocking or load-holding device.

CV08-20 Check Valve DIRECTIONAL VALVES. DESCRIPTION A screw-in, cartridge-style, hydraulic check valve for use as a blocking or load-holding device. DIRECTIONAL VALVES CV08-20 Check Valve DESCRIPTION A screw-in, cartridge-style, hydraulic check valve for use as a blocking or load-holding device. OPERATION The CV08-20 allows flow passage from 1 to 2,

More information

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics. Vickers heck Valves Operated heck Valves 4G-10, 20 Series, 20 Series 4T-06/10, 20 Series Typical Section 4T1-06-D*-20-U, illustrating external drain and decompression features asic haracteristics Maximum

More information

Double Pilot Operated Cartridge Check Valve, Size 8

Double Pilot Operated Cartridge Check Valve, Size 8 Double Pilot Operated Cartridge Check Valve, Size 8 Q max = 7 l/min (19 gpm), p max = 35 bar (5 psi) pilot operated, two-stage, spring-closed cartridge-type poppet valve Compact design for cavity type

More information

Leak-Free Load-Control Valve SAE ½ psi flange

Leak-Free Load-Control Valve SAE ½ psi flange Leak-Free Load-Control Valve SE ½ - 6000 psi flange Q max = 150 l/min [40 gpm], p max = 420 bar [6000 psi] leak-proof, two-stage hydraulic, SE-flange design 12--S... 1 Description Two-stage load-control

More information

Directional Controls

Directional Controls Vickers Directional Controls Directional Control Valves DG3V-3-*-60 Hydraulic Operated DG17V-3-*-60 Lever Operated DG18V-3-*-60 Air Operated DG20V-3-*-60 Cam Operated DG21V-3-*-60 Plunger Operated CETOP

More information

3-Way Pressure-Reducing Cartridge, Size 2 4

3-Way Pressure-Reducing Cartridge, Size 2 4 -Way Pressure-Reducing Cartridge, Size 2 Q max = 2 l/min, p max = 25 bar Spool-type design, direct acting, with manual adjustment 1 Description Compact construction for cavity type AM /- UNF to Bucher

More information

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US Industrial Hydraulic Valves Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories Catalog HY14-2500/US Industrial Hydraulic Valves WARNING USR RSPONSIBILITY FAILUR OR IMPROPR

More information

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08 Prop. -Way Pressure-Reducing Cart., Size / SAE 8 Q max = 1 l/min (4 gpm), p max = bar (6 psi) Direct acting, electrically operated 1 Description proportional -way pressure-reducing cartridges are size

More information

Pressure-Relief Cartridge Valve, Size 4

Pressure-Relief Cartridge Valve, Size 4 Pressure-Relief Cartridge Valve, Size 4 Q max = 30 l/min, p max = 420 bar Seated design, direct acting, with mechanical operation Compact construction for cavity type AL 3/4-16 UNF High flow rates 7 pressure

More information

Manapak Sandwich Valves Series CM, CPOM, FM, PRDM, PRM, RM

Manapak Sandwich Valves Series CM, CPOM, FM, PRDM, PRM, RM Catalog HY14-252/US Introduction Series C, CPO, F, PRD, PR, R anapak valves provide a variety of check, flow control, pressure relief and pressure reducing functions in a compact NFPA D3, D5 and D8 sandwich

More information

Full Range Pressure Compensating Variable Flow Control

Full Range Pressure Compensating Variable Flow Control Engineering & Manufacturing Solutions Specifications: See flow chart for capacity. Rated for 3000 psi (207 bar). Weighs 7- ¾ lbs. (3.52 kg). 30-Micron Filtration Recommended. Torque to turn side lever

More information

Directional Valves. Hydraulic Operated Directional Valves

Directional Valves. Hydraulic Operated Directional Valves Service Data Vickers Directional Valves Hydraulic Operated Directional Valves (F*) DG3V 8 (B) ** (L) (X) (*) (*) 10 (EN**) Released 04/96 5007.03/EN/0496/S DG3V-8-*(C) - (X) - 10 Spring Centered 473726

More information

Electrically Operated Pressure-Relief Cartridge, Size 10

Electrically Operated Pressure-Relief Cartridge, Size 10 Electrically Operated Pressure-Relief Cartridge, Size 1 Q max = 14 l/min (37 gpm), p max = bar (5 psi) seated pilot stage, spool-type design, with remote contral port Z Series WUVPOC-2, WUVPLC-2 1 Description

More information

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94 Vickers Flow Controls Flow Controls FN, F(C)G, FRG Released 6/94 685 Table of Contents FN03/06/10 Model Series Application Data...............................................................................

More information

Proportional Throttle Cartridges, Size 16

Proportional Throttle Cartridges, Size 16 Proportional Throttle Cartridges, Size 16 Q max = 5 l/min, p max = 5 bar, Q N max = 14 l/min at p 1 bar Two-Stage, with Seat-Valve Shut-Off 1 Description Normally closed Seat-valve shut-off from 1 Compact

More information

Cartridge Valves Technical Information. Pressure Reducing, Quick Reference

Cartridge Valves Technical Information. Pressure Reducing, Quick Reference Quick Reference Pressure Reducing, Non-Relieving Model No. Description Flow* Pressure Page CP20-2 PRC 06 SDC10- NCS06/ Pressure Reducing, Non-Relieving, Direct Acting 40 l/min [10 US gal/min] 40 l/min

More information

Pressure Reducing Valves Catalog Quick Reference

Pressure Reducing Valves Catalog Quick Reference Quick Reference Pressure Reducing, Non-Relieving Model No. Description Flow* Pressure Page 2 CP20-2 SDC0- Pressure Reducing, 20 bar PR - 5 PRC 06 NCS06/ Non-Relieving, Direct Acting [000 psi] 5 bar [4500

More information

SystemStak Valves. ISO4401 Size 02

SystemStak Valves. ISO4401 Size 02 SystemStak Valves ISO441 Size 2 Reduce System Space Requirements SystemStak valves make compact hydraulic systems in which specific function valves are sandwich mounted between a directional valve and

More information

Directional Controls

Directional Controls Vickers Directional Controls Lever Operator Directional Control Valves DG17S-8-**-10 DG17S4-10 **-50 NF D08/D10, ISO-4401-08/10 Released 5/94 681 able of Contents General Information..................................................................................

More information

VICKERS. SystemStak Valves. ISO ; NFPA-D03; 315 bar (4500 psi); 60 L/min (15.7 USgpm) GB 2027B

VICKERS. SystemStak Valves. ISO ; NFPA-D03; 315 bar (4500 psi); 60 L/min (15.7 USgpm) GB 2027B VICKERS SystemStak Valves ISO 441-3; NF-D3; 315 bar (45 psi); 6 L/min (15.7 USgpm) 1 G 227 uild a Compact, Cost-Effective, Reliable Hydraulic System with Vickers SystemStak Valves Reduces System Space

More information

Flow Controls. DG**-06 Series Stacking Valves. Vickers. ISO (D06) Interface Flows to 340 l/min (90 USgpm) Pressure to 210 bar (3000 psi)

Flow Controls. DG**-06 Series Stacking Valves. Vickers. ISO (D06) Interface Flows to 340 l/min (90 USgpm) Pressure to 210 bar (3000 psi) Vickers Flow Controls DG**-6 Series Stacking Valves ISO-441-8 (D6) Interface Flows to 34 l/min (9 USgpm) Pressure to 21 bar (3 psi) 5125./EN/598/A Introduction These stackable modules are designed for

More information

Contents. Catalog HY /US Load and Motor Control Valves SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

Contents. Catalog HY /US Load and Motor Control Valves SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI Load and Motor Control Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI STANDARD PILOT ASSISTED CB101... C10-3... Load Control Cartridge Valve...45/12... 380/5500... 5-6 MHC-010-S***

More information

shutoff valves 900 Series psig Manual Shutoff Valves

shutoff valves 900 Series psig Manual Shutoff Valves 0 6000 psig Manual Shutoff Valves Features Zero leakage Protected o-ring Full flow passages Freedom from wire drawing Panel mount standard Hand wheel or toggle handle How it Works Closed O-ring seal on

More information

P.C. Flow Regulator Valve Series FR101. General Description

P.C. Flow Regulator Valve Series FR101. General Description P.C. Flow Regulator Valve Series FR11 Compensated Flow Regulator Valve. NOTE: When used with a fixed displacement pump, pressure to the cartridge must be controlled by a relief valve located between the

More information

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Proportional Pressure-Relief Cartridge Valve, Size 2...4 Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description proportional pressure-relief valves are direct acting

More information

Inverse Proportional Pressure-Relief Cartridge, Size 10

Inverse Proportional Pressure-Relief Cartridge, Size 10 Inverse Proportional Pressure-Relief Cartridge, Size 1 Q max = 12 l/min, p max = 3 bar Seated pilot, spool-type main stage, damped design 1 Description inverse-proportional pressure-relief valves are size

More information

Inverse Prop. Pressure-Relief Cart., Size 2 4

Inverse Prop. Pressure-Relief Cart., Size 2 4 Inverse Prop. Pressure-Relief Cart., Size Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description inverse proportional pressure-relief valves are direct acting screw-in

More information

Pressure reducing valve, pilot operated, Model 3DR

Pressure reducing valve, pilot operated, Model 3DR RA 26 928/06.98 Pressure reducing valve, pilot operated, Model 3DR Nominal size 16 Series 5X Maximum operating pressure 3600 PSI (250 bar) Maximum flow 58.1 GPM (220 L/min) Contents Description Page Features

More information

Leak free Pipe Rupture Valve for Excavators

Leak free Pipe Rupture Valve for Excavators Leak free Pipe Rupture Valve for xcavators Series motion and progress Reference: 3 P 9575 1/11.6 Classification: 43.325.355...325.35 1/17 Contents Page 1 General description................................................................

More information

PVQ 13 A2 R SE 1 S 20 C-11 D

PVQ 13 A2 R SE 1 S 20 C-11 D PVQ - Variable Displacement Piston Pump PVQ 13 A2 R SE 1 S 2 C-11 D 1 2 3 4 6 7 8 9 1 1 Model Series PVQ Inline Piston Pump Variable Volume Quiet Series 4 Rotation Viewed from shaft end R Right hand, standard

More information

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to: LOW PRESSURE FILTERS Max Flow: gpm ( lpm) In-Tank Filters Working Pressures to: Rated Static Burst to: psi kpa bar psi kpa bar Flow Range to: gpm lpm Features STYLE C STYLE D STYLE E in-tank filters are

More information

Safety and Shut-off Block SAF/DSV

Safety and Shut-off Block SAF/DSV Safety and Shut-off Block SAF/DSV 1. DESCRIPTION 1.1. GENERAL The HYDAC safety and shut-off block is used to shut off and discharge hydraulic accumulators or consumers. It complies with the relevant safety

More information

Safety and Shut-off Block SAF/DSV

Safety and Shut-off Block SAF/DSV 1. DESCRIPTION 1.1. GENERAL The HYDAC safety and shut-off block is used to shut off and discharge hydraulic accumulators or user units. It complies with the relevant safety standards in accordance with

More information

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R Veljan Pressure Reducer Valve Series VR4R are pilot operated controls used to control pressure in a secondary part of a hydraulic circuit. Pressure is

More information

Safety and Shut-off Block SAF/DSV

Safety and Shut-off Block SAF/DSV Safety and Shut-off Block SAF/DSV 1.1.1 Key to the circuit diagram Circuit diagram The HYDAC safety and shut-off block is used to shut off and discharge hydraulic accumulators or consumers. It complies

More information

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ / - SE and SE Nominal flow rate up to 6 l/min / 8. gpm Description pplication For operation in units with hydrostatic drives, when

More information

Directional Control Valves Technical Information Model 1500

Directional Control Valves Technical Information Model 1500 Single spool monoblock valve. 26.4 l/min [7 US gal/min] maximum flow. 138 bar [2 psi] maximum pressure with relief. 27 bar [3 psi] maximum pressure without relief. Garden tractors, mowers, utility equipment,

More information

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R Veljan Pressure Reducer Valve Series VR4R are pilot operated controls used to control pressure in a secondary part of a hydraulic circuit. Pressure is

More information

Xpress L90LS Directional Control Valve. Catalog HY /UK December, 2001

Xpress L90LS Directional Control Valve. Catalog HY /UK December, 2001 Xpress L90LS Directional Control Valve Catalog HY17-8525/UK December, 2001 Catalogue HY17-8525/UK Technical Information Xpress - general information Xpress is a valve-customization service that enables

More information

PLD 03 T A CASAPPA S.p.A.

PLD 03 T A CASAPPA S.p.A. GEAR FLOW DIVIDERS INDEX Section Page GENERAL FEATURES... 3 GENERAL DATA... 5 FLOW EQUALIZER... 6 FLOW DIVIDERS... 8 TYPICAL CIRCUITS... 10 NOTES ABOUT COMPOSITION... 12 PORTS DIMENSIONS.... 14 GROUP DIMENSIONS...

More information

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

Displacement 12, , Maximum flow rate (at 1450 rpm) bar. 00/07 ED PVD VARIABLE DISPLACEMENT VANE PUMPS SERIES 0 OPERATING PRINCIPLE The PVD pumps are variable displacement vane pumps with a mechanical type of pressure compensator. They allow instantaneous adjustment

More information

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cart., Size 2 4 Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 35 bar Direct acting, electrically operated Description Compact construction for cavity type AL 3/-6 UNF Operated by a proportional

More information

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Proportional Pressure-Relief Cartridge Valve, Size 2...4 Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min, p max = 3 bar Direct acting, electrically operated 1 Description proportional pressure-relief valves are direct acting screw-in cartridges

More information

Description Advanced Features Typical Applications

Description Advanced Features Typical Applications Series single stage, brass barstock line regulator Description Advanced Features Typical Applications The Series regulators are intended for secondary pressure control of noncorrosive, high purity or liquefied

More information

directional control valve series cv691

directional control valve series cv691 directional control valve series cv691 Contents Page 3 Page 4 Page 5 Page 6-7 Page 8 Page 9 Page 10 Page 11-12 General Information Technical Data Performance Curves Dimensions Relief Valve Advantages

More information

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm Return Filters E 9 E E Tank top mounting Connection up to G / -6 SAE Nominal flow rate up to 5 l/min / 5.7 gpm Description Application In the return line circuits of hydraulic systems. Performance features

More information

Leak-Free Load-Control Valve, Size 20

Leak-Free Load-Control Valve, Size 20 Leak-Free Load-Control Valve, Size 20 Qmax = 350 l/min [92 gpm], pmax = 420 bar [6000 psi] leak-proof, two-stage hydraulic, manifold mounting 20--P... 1 Description Whenever large loads are to be precisely

More information

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cart., Size 2 4 Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 5 bar Direct acting, electrically operated 1 Description inverse proportional pressure-relief valves are direct acting screw-in cartridges

More information

Pressure reducing valve, direct operated

Pressure reducing valve, direct operated Electric Drives and Controls Table of contents Hydraulics Pressure reducing valve, direct operated Model ZDR 6 D Nominal size 6 Series 4X Maximum operating pressure 20 bar (3050 PSI) Maximum flow 50 L/min

More information

SDM to 8 sections monoblock valve D1WWDA02A

SDM to 8 sections monoblock valve D1WWDA02A SDM 1 SDM1 1 to 8 sections monoblock valve D1WWDA2A SDM1 Additional information This folder shows the product in the most standard configurations. Please contact Sales Dpt. for more detailed information

More information

BW0500AO. ByWire Elements BW0500AO Element 4/3 with side ports IBW0500 Interface

BW0500AO. ByWire Elements BW0500AO Element 4/3 with side ports IBW0500 Interface ywire Elements Element 4/3 with side ports IW5 Interface efore use, carefully read the GENERL INSTRUCTIONS FOR USE OF DIRECTIONL CONTROL VLVES 398SW5EN - 5--8 Technical data Nominal flow 5 l/min 3. US

More information

Cooler-Bypass Thermostat Valve, Size 16

Cooler-Bypass Thermostat Valve, Size 16 Cooler-Bypass hermostat Valve, Size Q max = l/min, p max = bar emperature-controlled, integral relief function, various pressure settings available Description emperature-dependent bypass control Integral

More information

F05MSV-N* CONTINENTAL HYDRAULICS FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK F05MSV-N* - FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK

F05MSV-N* CONTINENTAL HYDRAULICS FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK F05MSV-N* - FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK CONTINENTAL HYDRAULICS F05MSV-N* FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK F05MSV-N* - FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK 5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: 952.895.6400

More information

Pressure reducing valve, direct operated

Pressure reducing valve, direct operated Electric Drives and Controls Table of contents Hydraulics Pressure reducing valve, direct operated Model DR 10 DP Nominal size 10 Series 4X Maximum reduced pressure 210 bar (3050 PSI) Maximum flow 80 L/min

More information

DENISON HYDRAULICS vane pumps - single, double T6G - T67G - T6ZC

DENISON HYDRAULICS vane pumps - single, double T6G - T67G - T6ZC DENISON HYDRAULICS vane pumps - single, double T6G - T67G - T6ZC Publ. 1 - EN0709 - A 01 / 2000 / 2500 / FB Replaces : 1 - EN 084 - B L25-10709 - 1 CONTENTS GENERAL CHARACTERISTICS T67GB T6GC - T6ZC T67GB

More information

Pressure Sensing Valve - Model 4023

Pressure Sensing Valve - Model 4023 Pressure Sensing Valve - Model 4023 Overview AMOT Model 4023 can be used as a 2 or 3-way capacity, pressure sensing valve. This valve is ideal for applications that require compressor suction and discharge

More information

PTS1120TSJB PTS2120TSTSJB

PTS1120TSJB PTS2120TSTSJB Engineering & Manufacturing Solutions Specifications: 18 gpm (68.0 lpm) Nominal Capacity. Rated up to 3000 psi (207 bar). Port Sizes: -Inlet/Outlet #12 SAE. -Work Ports #10 SAE. 10 Micron Filtration Recommended.

More information

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm Return-Suction Filters E 08 Tank top mounting Connection up to G / -6 SE Nominal flow rate up to 80 l/min /. gpm Description pplication For operation in units with hydrostatic drives, when the return flow

More information

Cartridge Valves Technical Information Proportional Valves Quick Reference

Cartridge Valves Technical Information Proportional Valves Quick Reference Quick Reference Proportional Directional Model No. Description Flow* Pressure Page PSV-3- SDC- Proportional directional l/min 5. valve [6 ] [36 ] S 3 S Quick reference Proportional Directional Model No.

More information

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998 Auxiliary valve Sequence valve, 3-way Catalogue 9129 8542-02 (GB) 9129 8542-06 (US) October 1998 Sequence valve, 3-way Applications The sequence valve is designed to open or close a hydraulic pilot signal

More information

180 Series Rotary Shear Directional Control Valve

180 Series Rotary Shear Directional Control Valve 180 Series Rotary Shear Directional Control Valve Up to l 38 lpm, 10 US gpm l 700 bar, 10,000 psi Milwaukee, WI 53235, US el: +1 (414) 769-6400 sales-us@webtec.com St. Ives, Cambs. E27 3LZ, UK el: +44

More information

Over-center valves type LHT with oscillation damping, zero leakage

Over-center valves type LHT with oscillation damping, zero leakage Over-center valves type LHT with oscillation damping, zero leakage Flow rate Q max = 250 lpm Operation pressure p max = 450 bar See also: o Over-center valve type LHK acc. to D 7100 o Over-center valve

More information

MOUNTING SURFACE MOUNTING POSITION MAXIUMUM OPERATING PRESSURE FLUID OPERATING VISCOSITY FLUID CLEANLINESS HYSTERESIS REPEATABILITY THRESHOLD VOLTAGE

MOUNTING SURFACE MOUNTING POSITION MAXIUMUM OPERATING PRESSURE FLUID OPERATING VISCOSITY FLUID CLEANLINESS HYSTERESIS REPEATABILITY THRESHOLD VOLTAGE TYPICAL PERFORMANCE SPECIFICATIONS DESCRIPTION These proportional valves are direct operated pressure reducing valves. They can be used to control pressure in parts of a circuit. This valve incorporates

More information

Safety and Shut-off Block SAF/DSV

Safety and Shut-off Block SAF/DSV Safety and Shut-off Block SAF/DSV 1. Description 1.1. GENERAL The HYDAC safety and shut-off block is used to shut off and discharge hydraulic accumulators or consumers. It complies with the relevant safety

More information

3-Way Safety Block DSV

3-Way Safety Block DSV 3-Way Safety Block DSV DSV 10 - M DSV 10 - M - T-ball DSV 10 - EY 1. Description 1.1. GENERAL The 3-way safety block is used to shut off and discharge hydraulic accumulators or consumers. It complies with

More information

BACK PRESSURE / SUSTAINING

BACK PRESSURE / SUSTAINING In many liquid piping systems, it is vital that line pressure is maintained within relatively narrow limits. This is the function of the 108 Pressure Relief / Back Pressure Series of the OCV control valves.

More information

Safety and Shut-off Block SAF/DSV

Safety and Shut-off Block SAF/DSV Safety and Shut-off Block SAF/DSV 1. DESCRIPTION 1.1. GENERAL The HYDAC safety and shut-off block is used to shut off and discharge hydraulic accumulators. It complies with the relevant safety standards

More information

LV LOADER DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE

LV LOADER DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE LV LOADER DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE SPECIFICATIONS: 10 gpm (38 lpm) Nominal Capacity. Rated up to 4000 psi (275 bar). Port Sizes-Inlet/Outlet #8SAE (3/4-16). Work Ports #8SAE

More information

ANTI SHOCK RELIEF VALVE

ANTI SHOCK RELIEF VALVE ANTI SHOCK RELIEF VALVE Wheeler Road Coventry CV3 4LA England Brüsseler Allee 2 D-41812 Erkelenz Tel. +44(0)2476-217-400 Fax +44(0)2476-217-488 Tel. +49(0)24 31-80 91-0 Fax +49(0)24 31-80 91-19 www.sunhydraulics.com

More information

WORKHOLDING APPLICATION BOOKLET

WORKHOLDING APPLICATION BOOKLET WORKHOLDING APPLICATION BOOKLET Applications and advantages of using minibooster hydraulic pressure intensifiers MINIMUM SIZE MAXIMUM POWER B-GB Workholding 2018.04 1 of 20 2 of 20 B-GB Workholding 2018.04

More information

PVK OPEN LOOP PUMPS. Bulletin E

PVK OPEN LOOP PUMPS. Bulletin E PVK OPEN LOOP PUMPS Bulletin 47025-E Table of Contents Performance Assurance page 3 Features and Benefits page 4-5 Specifications page 6 Pump Controls page 7 Table of Contents Curves Performance page 8

More information

Series 1, 3 and 4 Cv = /8" and 1/4" Ported Manually Operated Valves. 3-way/2-position, 5-way/2-position, 5-way/3position

Series 1, 3 and 4 Cv = /8 and 1/4 Ported Manually Operated Valves. 3-way/2-position, 5-way/2-position, 5-way/3position Cv =.52 -.73 Series, 3 and 4 Cv =.52.3 /8" and /4" Ported Manually Operated Valves 3-way/2-position, 5-way/2-position and 5-way/3-position Ports /8 and /4" NPTF The Series (/8 & /4", 3-way/2-position and

More information

E Series Piston Pumps Variable Displacement Series for Mobile Applications Technical Catalog PVE012 PVE19 PVE21

E Series Piston Pumps Variable Displacement Series for Mobile Applications Technical Catalog PVE012 PVE19 PVE21 E Series Piston Pumps Variable Displacement Series for Mobile Applications Technical Catalog PVE012 PVE19 PVE21 Table of Contents Introduction......................................................................................................

More information

DANFLO Control Valves 400 Series Model 20

DANFLO Control Valves 400 Series Model 20 DANFLO Control Valves 400 Series Model 20 Back Pressure/Pressure Relief The DANFLO Model 20 is a pilot operated valve suitable for use in gas or liquid facilities and requires no outside power for operation.

More information

Pressure-limiting valve and pre-load valve type MVG, MVE and MVP

Pressure-limiting valve and pre-load valve type MVG, MVE and MVP Pressure-limiting valve and pre-load valve type MVG, MVE and MVP Product documentation Directly controlled Operating pressure pmax: Flow rate Qmax: 700 bar 8 lpm D 3726 02-2016-1.3 by HAWE Hydraulik SE.

More information

HIGH PRESSURE FILTERS DFDK Series Inline Duplex Filters 4568 psi up to 90 gpm

HIGH PRESSURE FILTERS DFDK Series Inline Duplex Filters 4568 psi up to 90 gpm DFDK Series Inline Duplex Filters 4568 psi up to 9 gpm Hydraulic Symbol DFDK QL L Ball Valve A DFDK QT T Ball Valve (sizes 33 or larger) A B B Features The DFDK Filters have a filter head of ductile iron

More information

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ and SE Nominal flow rate up to 6 l/min Description pplication For operation in units with hydrostatic drives, when the return flow

More information

Desiccant Air Breathers DBE. Section 3: TNK SCHROEDER INDUSTRIES ACCESSORIES 21

Desiccant Air Breathers DBE. Section 3: TNK SCHROEDER INDUSTRIES ACCESSORIES 21 Desiccant Air Breathers DBE Section 3: SCHROEDER INDUSTRIES ACCESSORIES 21 Reservoir Accessories A hydraulic systems reservoir can play a significant role in the ingression of contamination into the system.

More information

BACK PRESSURE / SUSTAINING

BACK PRESSURE / SUSTAINING SPECIFICATIONS DIMENSIONS In many liquid piping systems, it is vital that line pressure is maintained within relatively narrow limits. This is the function of the 108 Pressure Relief / Back Pressure Series

More information

Cartridge Valves Technical Information Motor Mount HICs Quick Reference

Cartridge Valves Technical Information Motor Mount HICs Quick Reference Quick Reference Symbol Description Order No. Page DH/DS MOUNT OMP/OMR/OMH MOUNT OMS MOUNT OMT MOUNT mount HIC Test lock 1125 15.21 1 1 2 2 3 3 4 4 P14 Symbol Description Model No. Page Dual counterbalance

More information

PRO-50 Instrument Supply Regulator

PRO-50 Instrument Supply Regulator Features CRN Approved The PRO-50 Regulator has been granted a Canadian Registration Number. Sour Service Capability Available in NACE configurations that comply with NACE MR0175/MR0103. Environmental limits

More information

HYDRAULIC MOTORS MTM APPLICATION OPTIONS CONTENTS EXCELLENCE GENERAL

HYDRAULIC MOTORS MTM APPLICATION OPTIONS CONTENTS EXCELLENCE GENERAL HYDRAULIC OORS APPLICAION» Skid Steer Loaders» etal working machines» renchers» Augers» Agricultural machines» Road building machines» Special vehicles» ine machines» Woodworking and sawmill machinery»

More information

Sandwich Valves. 1 Change in flow, temperature or fluid (SSU) rating will affect valve

Sandwich Valves. 1 Change in flow, temperature or fluid (SSU) rating will affect valve Technical Information Series PRM General Description Series PRM reducing valves are used to regulate pressure, in one area of a circuit, below normal system pressure. This style valve is well suited to

More information

SPC*01 (2-way) SPC03/06 (2-way) Size NG6 NG10 NG16 NG25 DIN A10 ISO 4401 NFPA D05 CETOP 5 P, A, B:

SPC*01 (2-way) SPC03/06 (2-way) Size NG6 NG10 NG16 NG25 DIN A10 ISO 4401 NFPA D05 CETOP 5 P, A, B: Catalog HY14-255/US Technical Information General Description sandwich type pressure s are typically used in combination with proportional directional control valves. The keeps the pressure drop over the

More information

APPLICATION. Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries

APPLICATION. Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries HYDRAULIC APPLICATION Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries Special vehicles Plastic and rubber machinery etc. CONTENTS Specification

More information

// ADapters GUIDelines

// ADapters GUIDelines // ADapters GUIDelines ADAPTER SELECTION Selection of an appropriate ALFAGOMMA adapter for a given application depends on the fluid system operating parameters listed below and the tube material and wall

More information

SPCH/ Blowing block

SPCH/ Blowing block > > for linear stretch blow moulding machines > > Compact and safe design > > Best suited for PET bottles up to litres, depending on cycle time Technical features Medium: Compressed air (purity class 3..3

More information

Pressure relief valve, direct operated

Pressure relief valve, direct operated Pressure relief valve, direct operated RE 570/0.05 Replaces: 06.03 /8 Type DBD..K Size Component series X Maximum operating pressure 500 bar Maximum flow 0 l/min K9- Table of contents Contents Page Features

More information

SG1 Series Regulators - Pressure Reducing

SG1 Series Regulators - Pressure Reducing SG1 Series Regulators - Pressure Reducing DSG131X Specifications For questions about this product, please consult TESCOM. OPERATING PARAMETERS Pressure rating per criteria of CGA E-; ASME B31; ASME BPVC

More information

Cartridges for pressure relief functions Hard seated ND 16 to 32 for water and oil up to 350bar

Cartridges for pressure relief functions Hard seated ND 16 to 32 for water and oil up to 350bar Stainless Steel Cartridge valves according to DIN44 The valves are designed for use with water, water and oil emulsions, oil and gases. Their roust construction and compact design provide long life, ease

More information

Choosing the right miniature instrument and control valve is a snap

Choosing the right miniature instrument and control valve is a snap Choosing the right miniature instrument and control valve is a snap INVALCO Micro Valve The Micro Valve is a unique miniature valve offering versatility and rugged construction. Since its introduction

More information

L125 SERIES POST-COMPENSATED SECTIONAL LOAD SENSE VALVE

L125 SERIES POST-COMPENSATED SECTIONAL LOAD SENSE VALVE L15 SERIES POST-COMPENSATED SECTIONAL LOAD SENSE VALVE TAKE CONTROL Take control with Muncie Power Products L15 directional control valve. The L15 is constructed with high-grade, iron castings and nickel-plated

More information

Pressure reducing valve, pilot operated

Pressure reducing valve, pilot operated Pressure reducing valve, pilot operated RE 26928/09.07 Replaces: 10.97 1/8 Type 3DR Size 16 Component series 5X Maximum operating pressure 250 bar Maximum flow 220 l/min H5844 Table of contents Content

More information