Damao Range. Single & Double Line Pressure Regulator - 4 or 8 bar

Size: px
Start display at page:

Download "Damao Range. Single & Double Line Pressure Regulator - 4 or 8 bar"

Transcription

1 Damao Range Single & Double Line Pressure Regulator - 4 or 8 bar Single and Double line pressure regulator for double stage medical gas distribution systems. 10 to 4 bar pressure regulator for all medial gases except Air to 8 bar pressure regulator for Air-800. Rapid installation For DAMAO double pressure regulator, both module regulators can be in operation or only one module. according to the FDS recommendations. These two configurations are allowed by an ingenious single adjustable plate. Identical inter-axe for both equipments. Easy to change gas flow direction. An aesthetic cover is optional. Double Pressure Regulator Damao Single Pressure Regulator Damao Performance High flow rate of 40 Nm 3 /h to supply many medical outlets. Complies with ISO and ISO standards. High level of safety Simple and safe design for rapid intervention in complete safety. Start/Stop lever on the front panel (Taema patent). Locking system guarantying one module regulator is in operation An aesthetic cover. Does not contain substances likely to give off toxic gases in case of fire. Easy maintenance Rapid maintenance because of a reduced number of components and patented interchangeable regulator modules. No maintenance required for gas notched connectors. The modules can be maintained separately while guarantying the gas flow distribution. Features Gases : O2, medical Air, N2, CO2, N2O, Air-800. Supply pressure : 5.5 to10 bar. Downstream pressure : preset at 4 bar (8 bar for motor gas), adjustable from 0 to 10 bar. Max. flow : 40 Nm 3 /h. Connections : brazing on 10 x 12 mm diameter copper tube. Pressure sensors : 4-20 ma analogic sensors or dry contacts. Sensor connections : M 10 x 100. Double DAMAO weight : 3.95 kg (cover not included). Single DAMAO weight : 2.91 kg (cover not included). Cover Weight : 0.3 kg. Total weight of magnetic material for each pressure regulator: Less than 145 g Double Pressure Regulator dimensions: mm (H) x 259 mm (L) x 107 mm (l). Cover dimensions : 216 mm (H) x 303 mm (L) x 120 mm (l). Upstream gauge : 0-16 bar. Downstream gauge : 0-10 bar (0-16 bar for motor gas). Manometer accuracy : ± 2.5 % full scale. EC-certified : CE 0459 Class IIb. Cleaning Cleaning : clean with rag lightly soaked in soapy water and rinse in clear water. Disinfection : with an alcohol-based solution (spray or wipes), with an EC-certified alcohol-based solution (Surfanios type). Do not immerse the device. Upkeep Annual functional check. Preventive maintenance every 2 years.

2 Single & Double Pressure Regulator Damao Modules Regulator Damao Cover Damao 0-16 bar Sensor Plastical seal Références Reference Designation Gas Type BB Double Pressure regulator Damao 4 BAR O 2 BB Double Pressure regulator Damao 4 BAR N2O BB Double Pressure regulator Damao 4 BAR Air BB Double Pressure regulator Damao 8 BAR Air-800 BB Double Pressure regulator Damao 4 BAR N2 BB Double Pressure regulator Damao 4 BAR CO2 NF BB Single Pressure regulator Damao 4 BAR O 2 BB Single Pressure regulator Damao 4 BAR N2O BB Single Pressure regulator Damao 4 BAR Air BB Single Pressure regulator Damao 8 BAR Air-800 BB Single Pressure regulator Damao 4 BAR N2 BB Single Pressure regulator Damao 4 BAR CO2 Each reference includes a complete Double pressure Regulator. Accessories et consumables Reference Designation Range Threading AF Analogic pressure sensor 4-20 ma 0-16 bar M 10 x 100 BY Flat gasket (x10) for mounting pressure sensor BB bar Module Regulator for rapid maintenance BB bar Module Regulator for rapid maintenance BB Cover for Damao (x5) YA Plastical seal (x10) Reference CY Valve key for Damao Regulator Modules Tool kit Designation Disassembly, assembly and maintenance should be performed by technicians trained according to procedures described in the maintenance manual (Ref YM (French version) & YM (English version)). Use only original Air Liquide Medical Systems manufacturer spare parts.

3 Damao Double dimensions Damao Simple dimensions

4 Damao Cover Dimensions

5 2 years Damao maintenance Kit Valve key for Damao Spare parts Reference CY years maintenance Kit Designation R25 O-ring 1 46 X 2 O-ring 2 Valve 3 O-ring 11,6 X 2,4 4 Sinterbronze filter O-ring 12,5 X 2 (X2) 7 BY Double Damao sealing plate 13 BY SingleDamao sealing plate 14 YV M4 X 8 CHC screw 10 AD Nut 11 AD Brazing socket 10 x CX Manometer 16B D40 RR M10X1 Primary network 15 CX Manometer 10B D40 RR M10X1 Secondary network 16 CX Manometer 16B D40 RR M10X1 Secondary network 16 CX Manometer diabolo gasket (x20) 8 CK NF O 2 BP serrated connector 17 CK NF Air BP serrated connector 17 CK NF CO 2 BP serrated connector 17 CK NF N2 BP serrated connector 17 CK NF N2O BP serrated connector 17 CK NF Air-800 BP serrated connector 17 CX Nylon shoulder gasket (x100) 9 YF Damao module label 4 bar 6 YF Damao module label 8 bar

PRESSURE REGULATORS AND FLOWMETERS, ALL MEDICAL GASES

PRESSURE REGULATORS AND FLOWMETERS, ALL MEDICAL GASES PRESSURE REGULATORS ALL MEDICAL GASES In this section we propose our pressure regulators (FM series, MU and MERCURY ) and our Rs flowmeters for applications other than oxygen therapy (presented in the

More information

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator Self-operated Pressure Regulators Type 2357-31 Pressure Build-up Regulator with safety function and integrated excess pressure valve Type 2357-31 with non-return unit at port C Ports A and B with soldering

More information

Hand lever valves VHER

Hand lever valves VHER Hand lever valves VHER Hand lever valves VHER Key features Powerful Flexible Practical -M- Flow 170 3800 l/min 4/3-way valve mid-position closed mid-position exhausted mid-position pressurised Connections:

More information

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv) THE BP-301 SERIES Operating and Service Manual Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv) Issue B October 2015 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation...

More information

Y:\Machine Manuals & Spare Parts Lists\PARTS BREAKDOWN\Commercial CW Gas\HD850WS Page 1

Y:\Machine Manuals & Spare Parts Lists\PARTS BREAKDOWN\Commercial CW Gas\HD850WS Page 1 1.0 PIECE PARTS - parts listing 1 5311-0710 Nut 1 2 5443-2820 Hose Stem 1 3 6362-3950 O-Ring Seal 14.0x1.78 1 4 6414-2820 Strainer 1 5 6313-0030 Spring 2 6 5321-1980 Handhold 1 7 5066-2120 Cover 1 8 5363-1350

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS 0/05 OPERATING INSTRUCTIONS for gas pressure regulators PN0 with integrated slam shut valve (SSV) and integrated limited capacity safety relief valve (RV) MR 25 F0, MR 25 SF0 p e 20 kpa - 0 MPa (0,2-0

More information

Flow control valves Series RFU - RFO 2/

Flow control valves Series RFU - RFO 2/ CATALOGUE > Release 8.5 > Valves Series RFU - RFO Flow control valves Series RFU - RFO Unidirectional and bidirectional flow control valves Ports: M5, G1/8, G1/4, G3/8 and G1/ Nominal diameter: M5 = 1,5

More information

R300 HELYON. Brass high pressure regulator, for compressed air, gas and liquids

R300 HELYON. Brass high pressure regulator, for compressed air, gas and liquids HELYON 5 Chemin du Jubin 69570 DARDILLY Tél. +33 (0)4 72 52 16 70 - Fax +33 (0)4 72 52 16 71 R300 Brass high pressure regulator, for compressed air, gas and liquids FEATURES Pressure regulator for inlet

More information

Self-operated Pressure Regulators for special applications

Self-operated Pressure Regulators for special applications Self-operated Pressure Regulators for special applications Type 2357-31 Pressure Build-up Regulator with safety function and integrated excess pressure valve Application Pressure regulators for cryogenic

More information

Avenger Model 33M Installation & Operation Instructions

Avenger Model 33M Installation & Operation Instructions Avenger Model 33M Installation & Operation Instructions Manufacturing Contact Information A+ Corporation, LLC Call for expert product application assistance: 41041 Black Bayou Rd. Gonzales, LA 70737 Phone:

More information

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691 THE BP-690 SERIES Operating and Service Manual Series includes all variants of BP-LF/MF-690/691 Issue B April 2015 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 4. Special

More information

INSTRUCTION MANUAL FOR POLYKEG DISPOSABLE KEG

INSTRUCTION MANUAL FOR POLYKEG DISPOSABLE KEG TABLE OF CONTENTS OF MANUAL Chapters 1.0 Product description 2.0 Safety rules for the utilisation of the keg 3.0 Instructions for manual filling 4.0 Instructions for automatic filling 5.0 Instructions

More information

R133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid

R133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid R133 Brass high pressure regulator, suitable for compressed air, gas and liquid HELYON 5 Chemin du Jubin 6957 DARDILLY Tél. +33 () 7 5 16 7 - Fax +33 () 7 5 16 71 FEATURES High pressure regulator for cylinder

More information

Specialists in HTM Medical Gas Pipeline Equipment AVSU/Module Operating and Maintenance Instructions

Specialists in HTM Medical Gas Pipeline Equipment AVSU/Module Operating and Maintenance Instructions The Area Value Service Units and Module format (AVSU) provide a local gas isolation facility for use during normal installation and maintenance or in the event of an emergency. They are built in accordance

More information

Genie Supreme TM Model 123HP Installation & Operation Instructions

Genie Supreme TM Model 123HP Installation & Operation Instructions Genie Supreme TM Model 123HP Installation & Operation Instructions Manufacturing Contact Information A+ Corporation, LLC Call for expert product application assistance: 41041 Black Bayou Rd. Gonzales,

More information

Genie Supreme Model 123 Installation & Operation Instructions

Genie Supreme Model 123 Installation & Operation Instructions Genie Supreme Model 123 Installation & Operation Instructions Manufacturing Contact Information A+ Corporation, LLC Call for expert product application assistance: 41041 Black Bayou Rd. Gonzales, LA 70737

More information

Installation and Maintenance Manual. Compact Medical Gas Outlets

Installation and Maintenance Manual. Compact Medical Gas Outlets Installation and Maintenance Manual Compact Medical Gas Outlets Contents Product Description 3 Cleaning and Lubricating 4 Inspection and Testing 4 Installation and Dimensions 5-6 Compact Outlet Indexing

More information

Cost effective. Smooth. Reliable. LOG Internal Hole Gripper

Cost effective. Smooth. Reliable. LOG Internal Hole Gripper LOG Cost effective. Smooth. Reliable. LOG Internal Hole Gripper Light gripper made of very resistant polyamide with closed diaphragm system Field of Application Particularly suited to highly dynamic applications

More information

Pressure reducing valves Series DRV/DRVM - DRVN/DRVMN

Pressure reducing valves Series DRV/DRVM - DRVN/DRVMN Pressure reducing valves Series DRV/DRVM - DRVN/DRVMN Main features Pressure reducing valves serve to reduce the pressure of the fluid downstream and to keep it at a constant level by varying its pressure

More information

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator. RHPS Series RD(H)F40 User Manual Read the complete manual before installing and using the regulator. 2 WARNING Before removing a regulator from the system for service, you must depressurize system purge

More information

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator. RS(H)10,15 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to

More information

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401 THE MF-400 SERIES Operating and Service Manual Series includes all variants of MF-400/401 Issue A October 2013 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 4. Special

More information

CENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES

CENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES P0170E-1.DOCX/08.16/MG CENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES With a Central Gas Supply System, individual work places or gas take-off stations are supplied with gas through

More information

NHR Powder Feed Hopper

NHR Powder Feed Hopper Instruction Sheet P/N 0804A0 NHR-8-50 Powder Feed Hopper Description This instruction sheet provides specifications, installation and operation instructions, and parts lists for the NHR-8-50 powder feed

More information

Si C132. Safety valves for pressure relief in accordance to PED, DIN/EN and ASME. Engineering GREAT Solutions

Si C132. Safety valves for pressure relief in accordance to PED, DIN/EN and ASME. Engineering GREAT Solutions Safety valves for pressure relief in accordance to PED, DIN/EN and ASME Engineering GREAT Solutions Si C132 Features The universal compact safety valve > 3 body seat sizes for appropriate size selection

More information

Instructions for use Compressed air injector with water trap

Instructions for use Compressed air injector with water trap Instructions for use Compressed air injector with water trap Table of Contents Introduction 1. Description of Functions 2. Putting into Operation 3. Instructions for Cleaning and Care 3.1 Disassembling

More information

STAINLESS STEEL LOW PRESSURE REDUCING VALVE LPRV ELITE

STAINLESS STEEL LOW PRESSURE REDUCING VALVE LPRV ELITE MAIN CHARACTERISTICS The stainless steel LPRV elite low pressure reducer is intended for the pressure reduction of the fluids such as water, air, clear liquids not in charge of and the compatible gases

More information

List of Contents vma. Compressed Air Conditioning 2. System description 2. Individual Units Pre-Filters 3. Combinations 6

List of Contents vma. Compressed Air Conditioning 2. System description 2. Individual Units Pre-Filters 3. Combinations 6 Úprava stlačeného vzduchu EWO VMA List of Contents System description Individual Units Pre-Filters 3 Micro-Filters 4 Activated-Charcoal-Filters 5 Combinations 6 Accessories and Main spare parts 6 Service

More information

PRESSURE REDUCTION FLOWMETERING, QUICK COUPLING PROBES AND ACCESSORIES

PRESSURE REDUCTION FLOWMETERING, QUICK COUPLING PROBES AND ACCESSORIES PRESSURE REDUCTION FLOWMETERING, QUICK COUPLING PROBES AND ACCESSORIES 1 3 1 - ALPINOX: oxygen Regulator - Medical oxygen regulator with flowmeter. - Medical oxygen regulator with flowmeter and Quick

More information

VALVES HIDROMATIC VALVE.

VALVES HIDROMATIC VALVE. VALVES HIDROMATIC VALVE Hydrodynamic design The Hidromatic valve of Hidroconta is a piston hydraulic valve controlled with the same fluid of the conduction. Its balloon design improves its hydrodynamic

More information

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25 Self-operated Pressure Regulators Differential Pressure Regulators (opening) Type 42-20 Type 42-25 Type 42-20 Differential Pressure Regulator Type 42-25 Differential Pressure Regulator Mounting and Operating

More information

HIGH-PRESSURE RELIEF VALVES

HIGH-PRESSURE RELIEF VALVES HIGH-PRESSURE RELIEF VALVES H-9HP SERIES FEATURES n St.St. 316 Construction n MAWT up to 6 psi n Set Pressure from 5 psig to 6 psig ( 3.5 to 4 bar) n Identifying colored springs for each pressure range

More information

Technical Specification

Technical Specification Medical Gas Terminal Units (Gas Outlet Points) Technical Specification EN 9170-1 Terminal Unit Product Description CPX Terminal Units comprise a first fix, second fix and check valve. The first fix assembly

More information

Operation Manual Piston Sensed Gas Pressure Regulators

Operation Manual Piston Sensed Gas Pressure Regulators 687 Technology Way Napa, CA 94558 Phone: (707) 259-0102 FAX: (707) 259-0117 www.aptech-online.com Operation Manual Piston Sensed Gas Pressure Regulators (Models KT9, KT10, Welded KT10, KT12) Table of Contents:

More information

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators Technical Instructions Document No. 155-51P5 VG August 11, 005 GAS009R1 VGG VGD0 VGD0 Description Only when assembled to SKP

More information

CONNECTION > Super-rapid fittings Series 6000 GENERAL DATA. Fitting with connecting tube. Sprint

CONNECTION > Super-rapid fittings Series 6000 GENERAL DATA. Fitting with connecting tube. Sprint Super-rapid fittings for plastic tubes Series 6000 Sprint Tube external diameters: 3,, 5, 6, 8, 10, 12, 1, 16 mm Fittings threads: metric (M3, M5, M6, M7), BSP (G1/8, G1/, G3/8, G1/2, G3/), BSPT (R1/8,

More information

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN Differential Pressure Regulator Type 45-6 Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN Edition March 2008 Contents Contents Page 1 Design and principle of operation...................

More information

Regulators/valves Compressed air regulators Without filter

Regulators/valves Compressed air regulators Without filter Regulators/valves Compressed air regulators Regulators/valves Compressed air regulators Without filter 0 to 7 bar 0 to 7 bar controllable, with automatic vent, admission pressure-independent. Operating

More information

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012 Installation Guide English September 2012 299H Series Introduction This Installation Guide provides instructions for installation, startup, and adjustment of 299H Series regulators. To receive a copy of

More information

Technical Information Cleanfit CUA451

Technical Information Cleanfit CUA451 TI00369C/07/EN/13.13 71238305 Products Solutions Services Technical Information Cleanfit CUA451 Manually operated retractable assembly for water, wastewater and process media Application Drinking water

More information

MoveRoll Conveyor Operating and Maintenance Manual

MoveRoll Conveyor Operating and Maintenance Manual MoveRoll Conveyor Operating and Maintenance Manual 1. Read this first! This manual contains information for protection of personnel in the roll handling area from possible injury and/or equipment damage.

More information

Spare parts list ( ) Spare parts list HD 1.8/13 C Ed

Spare parts list ( ) Spare parts list HD 1.8/13 C Ed Spare parts list (5.972-842.0) Spare parts list HD 1.8/13 C Ed 26.05.2015 www.kaercher.com EN Table of contents Spare parts list HD 1.8/13 C Ed (5.972-842.0)... 6 10 Housing... 7 11 Housing... 8 12 Hand

More information

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator. LRS(H)4 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to the

More information

Purgemaster Series 10A6100 SNAP-IN. Instruction Bulletin Replaceable Parts List. D184B003U35 Rev. 01 /

Purgemaster Series 10A6100 SNAP-IN. Instruction Bulletin Replaceable Parts List. D184B003U35 Rev. 01 / SNAP-IN Purgemaster Series 0A600 Instruction Bulletin Replaceable Parts List D84B003U35 Rev. 0 / 03.200 You have purchased a high quality, modern instrument from ABB Automation Products. We thank you for

More information

Pressure booster combination DPA-CRVZS. Operating instructions a [ ]

Pressure booster combination DPA-CRVZS. Operating instructions a [ ] Pressure booster combination en Operating instructions 8074546 2017-07a [8074548] Original instructions -EN Identification of hazards and instructions on how to prevent them: Danger Immediate dangers which

More information

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO Instructions for Use Plug connection for medical gas and vacuum acc. to DIN 13260-2 / 2004 DIN EN ISO 9170-1 Table of Contents Page 1. MANUFACTURER S DATA... 3 2. INTRODUCTION... 4 3. APPLICATION... 5

More information

screw fittings - nickel plated brass series SC

screw fittings - nickel plated brass series SC screw fittings - nickel plated brass series SC SC SCC SC SC SC SC SC SCC SC SC SC SCC SC SC SC2C SC2 SC2 SC SC3 SC3 SC0 SC design screw fitting with swivel nut connection 1/"...1/2" optionally cylindrical

More information

Compressed Air Conditioning Catalog Chapter I

Compressed Air Conditioning Catalog Chapter I Compressed Air Conditioning Catalog Chapter I 2 Compressed Air Conditioning Welcome Welcome New technologies and materials, design innovations and the integration of bus-suitable electronics have opened

More information

AREA VALVE SERVICE UNITS

AREA VALVE SERVICE UNITS AREA VALVE SERVICE UNITS. Unit 8, McKenzie Industrial Park, Tel No.: 44 (0) 161 428 7200 Bird Hall Lane, Fax No.: 44 (0) 161 428 7010 Stockport, Email: info@p3-phoenix.com U.K., SK3 0SB www.p3-phoenix.com

More information

Precision and Instrument Regulators 1/4" port size

Precision and Instrument Regulators 1/4 port size Section 8 Precision and Instrument Regulators /" port size Contents -8 Precision Air Pressure Regulator /" ports............ale-8-2 R38 Instrument Regulator Aluminum Model /" ports.........ale-8- -8 R38

More information

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator. PRS(TC)4,8 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to

More information

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS FILTER REGULATORS MODEL NO: CAT155 & CAT156 PART NO: 3120169 & 3120170 FITTING & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC0117 INTRODUCTION Thank you for purchasing this CLARKE Filter/Regulator.

More information

PRESSURE REGULATORS GAS BACK PRESSURE NON VENTING

PRESSURE REGULATORS GAS BACK PRESSURE NON VENTING GAS BACK PRESSURE NON VENTING APPLICATION: Vent lines or pressure regulation on separators, heater treaters, compressor stations, gas gathering and distribution systems where it is desired that no gas

More information

ALE-40. R06 Miniature Brass Body Regulator. Water and Compressed Air Service 1/8" and 1/4" PTF Port Sizes. Air line equipment.

ALE-40. R06 Miniature Brass Body Regulator. Water and Compressed Air Service 1/8 and 1/4 PTF Port Sizes. Air line equipment. Air line equipment R Miniature Brass Body Regulator Water and Compressed Air Service 1/" and 1/" PTF Port Sizes Compact design, corrosion resistant construction Brass body with choice of plastic or brass

More information

book : t95575.fm Seite 1 Mittwoch, September 20, :10 AM. Avensys. Exposed Single Lever Mixer

book : t95575.fm Seite 1 Mittwoch, September 20, :10 AM. Avensys. Exposed Single Lever Mixer 955751.book : t95575.fm Seite 1 Mittwoch, September 20, 2000 10:10 AM Avensys Exposed Single Lever Mixer 33 389 33 396 Installation Instructions and Operating Guide Please leave this document with the

More information

Series K Air service units G 1/8, G 1/4

Series K Air service units G 1/8, G 1/4 Air service units G /8, G /4 Series FK Filter, G /8 G /4.02 Series RK Pressure regulator, G /8 G /4.04 Series FRK Filter/regulator, G /8 G /4.06 Series OK Lubricator, G /8 G /4.08 Series FROK Two piece

More information

FILTER, REGULATOR AND FILTER/REGULATOR Stainless Steel 316L Compact 1/4, High Flow 1/4-1/2

FILTER, REGULATOR AND FILTER/REGULATOR Stainless Steel 316L Compact 1/4, High Flow 1/4-1/2 FILTER, REGULATOR AND FILTER/REGULATOR Stainless Steel L Compact /, High Flow / - / Air service equipment Series FEATURES Stainless Steel filter, regulator and filter regulator intended for corrosive environment

More information

Serie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E

Serie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E Serie ECO T Threaded end back flow preventer with controllable reduced pressure zone BRANDONI made in E U R O P E Application fields WATER FIRE FIGHTING DRINKING WATER 74 www.brandoni.it Serie ECO T The

More information

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC 05 Elster GmbH Edition 0.5 Translation from the German 058 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Linear flow control VFC Linear flow control with actuator IFC Contents

More information

Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap

Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap 0509950/2 IM-P050-21 CH Issue 2 Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation and

More information

30T A/Manual Hydraulic Shop Press

30T A/Manual Hydraulic Shop Press 30T A/Manual Hydraulic Shop Press Operation Manual 1 1. Important Information 1.1 Safety Information 1.1.1 Hazard Symbols Used in the Manuals This manual includes the hazard symbols defined below when

More information

SPECIALIST GAS VALVES AND FITTINGS

SPECIALIST GAS VALVES AND FITTINGS SPECIALIST GAS VALVES AND FITTINGS 0 HISTORY 1830 1900 1987 1997 1998 2007 2009 Creation of Chuchu Decayeux Chuchu Decayeux manufactures and creates gas lighting systems Chuchu Decayeux begins to specialize

More information

Making medical procedures easier

Making medical procedures easier Oxygen Therapy and Medical Suction Catalogue Making medical procedures easier www.airliquidemedicalsystems.com Air Liquide Healthcare is a world leader in medical gases, home healthcare, hygiene products

More information

Type PRX/120, PRX/125, PRX-AP/120, PRX-AP/125, PRX/181, PRX/182, PRX/131 and PRX-AP/131 Pilots

Type PRX/120, PRX/125, PRX-AP/120, PRX-AP/125, PRX/181, PRX/182, PRX/131 and PRX-AP/131 Pilots Instruction Manual 0006EN-PRX-IM PRX Series July 2008 - Rev. 00 Type PRX/120, PRX/125, PRX-P/120, PRX-P/125, PRX/1, PRX/2, PRX/131 and PRX-P/131 Pilots summary Introduction... 1 Characteristics... 1 Labelling...

More information

Spare parts list ( ) Spare parts list HDS 700 B

Spare parts list ( ) Spare parts list HDS 700 B Spare parts list (5.955-875.0) Spare parts list HDS 700 B 02.09.2013 www.kaercher.com EN Page 2 Page 3 Page 4 Table of contents Spare parts list HDS 700 B (5.955-875.0)... 6 10 Individual parts... 7 11

More information

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators Technical Instructions Document No. 155-51P5 VG August 1, 01 VGG VGD0 VGD0 Description Only when assembled to Series SKP actuators

More information

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION INSTALLATION INSTRUCTIONS CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION The CVS Controls 67CFR Filter regulator is a pressure reducing supply regulator typically used for pneumatic

More information

PRESSURE REGULATORS GAS PRESSURE REDUCING

PRESSURE REGULATORS GAS PRESSURE REDUCING GAS PRESSURE REDUCING APPLICATION: Regulation of inlet pressure to gas compressors. Control of supply or distribution system pressure CERTIFICATIONS: Canadian Registration Number (CRN): 0C16234.24567890NTY

More information

Types and approvals. Page 1/6. Data Sheet

Types and approvals. Page 1/6. Data Sheet Page 1/6 Panel-mounting Thermostats EM Series as: Protection temperature monitor STW (STB) Protection temperature limiter STB tested to DIN 3440 and Pressure Equipment Directive 97/23/EC Brief description

More information

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity Type 4708-45 Supply Pressure Regulator with increased air capacity Translation of original instructions Mounting and Operating Instructions EB 8546-1 EN Edition March 2016 Note on these mounting and operating

More information

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions VS18/26 with PROFINET and EtherNet/IP Interface ATEX Installation Instructions INDEX 1. INTENDED USAGE 3 2. OPERATING MANUAL ATEX 4 2.1 General conditions 4 2.2 Installation 5 2.3 Operating 5 2.4 Failures

More information

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301 THE HF-300 SERIES Operating and Service Manual Series includes all variants of HF-300/301 Issue A July 2015 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 3.1. Spring Loaded...

More information

Universal Charging and Testing Unit FPU-1

Universal Charging and Testing Unit FPU-1 1. DESCRIPTION 1.1. FUNCTION The charging and testing unit FPU-1 is used to charge accumulators with nitrogen or to check or to change the existing pre-charge pressure in accumulators. For this purpose

More information

Type 4708 Supply Pressure Regulator

Type 4708 Supply Pressure Regulator Type 478 Pressure Regulator Application pressure regulators used to provide pneumatic measuring and control equipment with a constant air supply Set point ranges. to. bar ( to 4 psi). to bar (8 to 9 psi)

More information

1301 Series High-Pressure Regulators

1301 Series High-Pressure Regulators Instruction Manual Form 1111 Types 1301F and 1301G March 2013 1301 Series High-Pressure Regulators! WARNING Failure to follow these instructions or to properly install and maintain this equipment could

More information

PSH. Application example. Pneumatic 2-Finger Parallel Gripper Long-stroke Gripper. Stroke per finger 14 mm.. 64 mm. Sizes

PSH. Application example. Pneumatic 2-Finger Parallel Gripper Long-stroke Gripper. Stroke per finger 14 mm.. 64 mm. Sizes PSH Sizes 22.. 52 Weight 0.77 kg.. 8.05 kg 320 N.. 1760 N Stroke per finger 14 mm.. 64 mm Workpiece weight 1.60 kg.. 8.80 kg Application example Rapid loading and unloading unit on a swivel head base.

More information

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron EN GJL 250 body. Reinforced lug for DN200 :

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron EN GJL 250 body. Reinforced lug for DN200 : Reinforced lug for DN200 : Size : Ends : Min Temperature : Max Temperature : DN 50 to 200 mm Between flanges ISO PN10/16 ( PN10 for DN200 ) - 10 C + 110 C Max Pressure : 10 Bars Specifications : Long neck

More information

Differential pressure

Differential pressure Differential pressure 9 Overview Page 200 VEGADIF 65 Page 202 Chemical seal Page 204 Accessory Page 208 199 VEGADIF For differential pressure, level and flow measurements Measuring principle The sensor

More information

MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE

MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE SIT Group SIT -3- SIGMA MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE 9.955. Subject to change without notice Application Domestic gas appliances: central heating boilers, combi boilers, instantaneous

More information

Safety and Shut-off Block SAF/DSV

Safety and Shut-off Block SAF/DSV Safety and Shut-off Block SAF/DSV 1. DESCRIPTION 1.1. GENERAL The HYDAC safety and shut-off block is used to shut off and discharge hydraulic accumulators or consumers. It complies with the relevant safety

More information

Flowmeter. Original operating manual DFM

Flowmeter. Original operating manual DFM Flowmeter Original operating manual Series DFM 165 350 Version BA-2016.08.09 EN Print-No. 300 458 TR MA DE Rev002 ASV Stübbe GmbH & Co. KG Hollwieser Straße 5 32602 Vlotho Germany Phone: +49 (0) 5733-799-0

More information

PSH (inch version) Application example. Pneumatic 2-Finger Parallel Grippers Long-stroke Grippers. Stroke per finger 14 mm.. 64 mm. Sizes 22..

PSH (inch version) Application example. Pneumatic 2-Finger Parallel Grippers Long-stroke Grippers. Stroke per finger 14 mm.. 64 mm. Sizes 22.. PSH (inch version) Sizes 22.. 52 Weight 0.77 kg.. 8.05 kg Gripping force 320 N.. 1760 N Stroke per finger 14 mm.. 64 mm Workpiece weight 1.60 kg.. 8.80 kg Application example Rapid loading and unloading

More information

Dival 500 Pressure Regulators

Dival 500 Pressure Regulators Dival 500 Pressure Regulators Dival 500 Classification and Range of use The DIVAL 500 is a downstream direct-acting pressure regulator with balanced plug, for low, medium and high pressures. Suitable for

More information

3-Way Pressure-Reducing Cartridge, Size 2 4

3-Way Pressure-Reducing Cartridge, Size 2 4 -Way Pressure-Reducing Cartridge, Size 2 Q max = 2 l/min, p max = 25 bar Spool-type design, direct acting, with manual adjustment 1 Description Compact construction for cavity type AM /- UNF to Bucher

More information

RS(H)20, 25 USER MANUAL

RS(H)20, 25 USER MANUAL RS(H)20, 25 USER MANUAL Read the complete manual before installing and using the regulator. WARNING Before removing a regulator from the system for service, you must depressurize system purge the system

More information

Pneumatic spool valve islands

Pneumatic spool valve islands Pneumatic spool valve islands P7.GB.R MEGA SPOOL VALVE ISLANDS MEGA pneumatic spool valve islands offer maximum performance along with flexibility, easy installation and simple operation. Due to their

More information

Beamex PG PRESSURE GENERATORS. Beamex PGM PGV PGC PGHH PGPH PGL

Beamex PG PRESSURE GENERATORS. Beamex PGM PGV PGC PGHH PGPH PGL Beamex PG PRESSURE GENERATORS 97 Beamex PGM PGV PGC PGHH PGPH PGL Beamex PG pressure generators are portable hand-operated pressure generators and ultimate field calibration pumps 98 Calibration pumps

More information

PRESSURE REGULATORS GAS PRESSURE REDUCING

PRESSURE REGULATORS GAS PRESSURE REDUCING GAS PRESSURE REDUCING APPLICATION: Regulation of inlet pressure to gas compressors. Control of supply or distribution system pressure CERTIFICATIONS: Canadian Registration Number (CRN): 0C16234.24567890NTY

More information

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0) Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW Tel +44 (0)1254 615100 www.allspeeds.co.uk HP690A Intensifier Panel including the following versions: Model Intensification

More information

INDUSTRIAL EXCESS ESS FLOW VALVES

INDUSTRIAL EXCESS ESS FLOW VALVES INDUSTRIAL EXCESS ESS FLOW VALVES H-911 SERIES FEATURES n Stainless Steel Construction n MAWP 6000 psi (413 bar) n MAWT 400 F (204 C) n Variable connection sizes (1/8 to 1/2'' & 6 to 12mm) n Cv = 0.5 ;

More information

Spare parts list ( ) Spare parts list HD 2.3/14 C Ed Food

Spare parts list ( ) Spare parts list HD 2.3/14 C Ed Food Spare parts list (5.972-564.0) Spare parts list HD 2.3/14 C Ed Food 05.08.2013 www.kaercher.com EN Page 2 Page 3 Page 4 Table of contents Spare parts list HD 2.3/14 C Ed Food (5.972-564.0)... 6 10 Housing

More information

User manual. ZX trolley.

User manual. ZX trolley. User manual. ZX trolley. Date July 2011 02 User manual. ZX trolley. ZX trolley. Safe transportation for medical gas cylinders. Important Please read this manual carefully before attempting to use the BOC

More information

LRS(H)4 Pressure-Reducing Regulator User Manual

LRS(H)4 Pressure-Reducing Regulator User Manual LRS(H)4 Pressure-Reducing Regulator User Manual Read the complete manual before installing and using the regulator. 2 Safe Product Selection When selecting a product, the total system design must be considered

More information

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide Pilot HON 62 Entwurf Product information serving the gas industry worldwide Pilot HON 62 Application, characteristics Application Pilot for the gas pressure regulator HON 02 Pilot for outlet pressure control

More information

Pneumatic retractable fitting for simple commercially available control units or process applications

Pneumatic retractable fitting for simple commercially available control units or process applications Pneumatic Retractable Fittings hem Energy Pharm Food Water SensoGate W 3 Pneumatic retractable fitting for simple commercially available control units or process applications Variable and reasonably priced

More information

Variable Area Flow Meters

Variable Area Flow Meters Variable Area Flow Meters Over sixty years of variable area meter expertise Brooks started designing and manufacturing variable area (VA) meters, also referred to as rotameters, in 1946. Now, with more

More information

IP2, IP2A and IP2D. Spirax-Monnier International Compressed Air Filter/ Regulators

IP2, IP2A and IP2D. Spirax-Monnier International Compressed Air Filter/ Regulators Page 1 of 6 TI-P510-01 H Issue 5 IP2, IP2 and IP2D ISO 9001 Spirax-Monnier International ompressed ir Filter/ Regulators ert. No. LRQ 0963008 Description The IP range of Spirax-Monnier international compressed

More information

AIR/OVER HYDRAULIC JACK 20 TON

AIR/OVER HYDRAULIC JACK 20 TON AIR/OVER HYDRAULIC JACK 0 TON 4487 ASSEMBLY AND OPERATING INSTRUCTIONS 349 Mission Oaks Blvd., Camarillo, CA 930 Visit our Web site at http://www.harborfreight.com Copyright 999 by Harbor Freight Tools.

More information

Series MX pressure regulators 3/

Series MX pressure regulators 3/ CATALOGUE > Release 8.8 > Series MX regulators Series MX pressure regulators MX2 ports: G/8, G1/2, G/4 - MX ports: G/4, G1 Manifold ports: G1/2 (MX2 only) Modular - Available with built-in pressure gauges

More information

Air service units series K G1/8, G1/4

Air service units series K G1/8, G1/4 Air service units series K Series FK Filter 12.011 Series RK Pressure regulator 12.012 Series FRK Filter/regulator 12.013 Series OK Lubricator 12.014 Series FROK Two piece air service unit 12.015 Series

More information