Diaphragm accumulator type AC

Size: px
Start display at page:

Download "Diaphragm accumulator type AC"

Transcription

1 Diaphragm accumulator type AC Product documentation Operating pressure pmax: 350 bar Capacity V0 max: 2.8 dm 3 D

2 by HAWE Hydraulik SE. The reproduction and distribution of this document as well as the use and communication of its contents to others without explicit authorisation is prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of patent or utility model applications. Brand names, product names and trademarks are not specifically indicated. In particular with regard to registered and protected names and trademarks, usage is subject to legal provisions. HAWE Hydraulik respects these legal provisions in all cases. Printing date / document generated on: /26 D AC HAWE Hydraulik SE

3 Contents 1 Overview diaphragm accumulator type AC Available versions, main data Available versions Parameters General Dimensions Diaphragm accumulator Assembly, operation and maintenance recommendations General notes Safety instructions Legal provisions Transport and storage Intended application Assembly information Installation and commissioning Operating instructions Maintenance information Replacing USIT ring (20) Checking gas lling pressure Other information Notes regarding the lay-out Accessories, spare parts and separate components Testing device DFM Mounting brackets Fittings HAWE Hydraulik SE D AC /26

4 1 Overview diaphragm accumulator type AC Diaphragm accumulators are a type of hydraulic accumulator. A diaphragm separates the compressible gas cushion from the hydraulic uid. The diaphragm accumulator type AC is used as a source of pressurized oil. It supports or increases the pump delivery ow or stores pressure energy, e.g. for an accumulator charge circuit. With the aid of different ttings the hydraulic accumulator type AC can be integrated into a hydraulic system. Different installation orientations and installation positions are possible. Features and bene ts: Compact design Option of integration into the HAWE modular system Operating pressures up to 350 bar Intended applications: Clamping systems Jigs Accumulator charging systems Diaphragm accumulator type AC These accumulators are used to: store pressure energy support the pump delivery improve system efficiency pulsation dampening in hydraulic systems compensation of pressure variations due to temperature changes compensate internal leakage (when apparent) 4/26 D AC HAWE Hydraulik SE

5 2 Available versions, main data 2.1 Available versions Symbol: Examples: AC 2001 AC 1002 /90 /140 /3A /22 Connection thread (hydraulic side) Table 3 Connection thread Gas lling pressure Table 2 Gas pre-load pressure p 0 (bar) Basic type Table 1 Basic type Table 1 Basic type Basic type Nom. volume V 0 (dm 3 ) Max. perm. operating pressure p max (bar) Max. perm. pressure ratio p 2/p 0 Max. perm. pressure dyn. difference p 2 - p 1 AC / AC / AC / AC / AC / AC / AC /1 120 o AC /1 65 o AC /1 140 o AC /1 140 o CE - stamping plus letter of conformity HAWE Hydraulik SE D AC /26

6 Table 2 Gas pre-load pressure Basic type AC AC AC AC AC AC AC AC AC AC Max. gas pre-load pressure p 0 (bar) For information on the gas pre-load pressure p 0 see also Chapter 6.1, "Notes regarding the lay-out" For information on accessories, spare parts and individual parts see also Chapter 6.2, "Accessories, spare parts and separate components" 6/26 D AC HAWE Hydraulik SE

7 Table 3 Connecting thread Basic type Connecting thread Marking Description AC 0725 /1A - G 1/4A * AC 202 /3 /1A /2A /2AW /3A AC 322 /3 /1A /2A /2AW AC 603 /3 /1A /2A /2AW /3A AC 1002 /22 /2A /2AW /3A AC 1414 /22 /2A /2AW /3A AC 1035 /3 /1A /2A /2AW /3A AC 2001 /3A - G1/2A * AC 2002 /4 /3A AC 2825 /3 /1A /2A /2AW /3A * Basic version - G 1/2 (internal thread) * - G 1/4A - G 1/2A - G 1/2 (internal thread) * - G 1/4A - G 1/2 (internal thread) * - G 1/4A - G 1/2A - M22x1.5 (internal thread) * - M33x1.5 (external thread) * - G 1/2A (external thread) * - M22x1.5 (internal thread) * - M33x1.5 (external thread) * - G 1/2A - G 1/2 (internal thread) * - G 1/4A - G 1/2A - G 3/4 (internal thread) * - G 1/2A - G 1/2 (internal thread) * - G 1/4A - G 1/2A HAWE Hydraulik SE D AC /26

8 3 Parameters 3.1 General Design Surface protection Installed position Mounting Diaphragm type accumulator conforming Pressure Equipment Directive PED 97/23/EC All types welded design Enameled (2k paint) Preferable vertical position (with the uid connection at the bottom), horizontal Directly via pipe ttings. Note Ensure the pipe screw connection is correctly assembled. In the event of strong vibrations, secure the accumulator to prevent it from coming loose. Gas lling Temperature Only N 2 (nitrogen)! } uid: -10 C C } Oil: -35 C C for type AC 0725, AC 202, AC 603, AC 1035, AC 2825 Hydraulic uid Hydraulic oil: according to Part 1 to 3; ISO VG 10 to 68 according to DIN Viscosity range: min. approx. 10, max. approx. 300 mm 2 /s Optimal operating range: approx. 10 to 35 mm 2 /s Also suitable for biologically degradable pressure uids type HEES (synthetic ester) at operating temperatures up to approx. +70 C. Diaphragm material Lifetime NBR ECO (compound) for type AC 0725, AC 202, AC 603, AC 1035, AC x 10 9 cycles For all other operating conditions the lifetime in accordance with PD 5500 Annex C must be observed (Pressure Equipment Directive) Weight Type AC 0725 Type AC 202 Type AC 322 Type AC 603 Type AC 1002 Type AC 1414 Type AC 1035 Type AC 2001 Type AC 2002 Type AC 2825 = 0.75 kg = 1.0 kg = 1.3 kg = 3.0 kg = 3.5 kg = 6.0 kg = 7.5 kg = 4.0 kg = 7.5 kg = 8.6 kg 8/26 D AC HAWE Hydraulik SE

9 4 Dimensions All dimensions in mm, subject to change. 4.1 Diaphragm accumulator Type AC 0725 /1A Type AC 202 /1A Type AC 202 /2A Type AC 202 /2AW Type AC 202 /3 Type AC 202 /3A See also Chapter 6.2, "Accessories, spare parts and separate components" HAWE Hydraulik SE D AC /26

10 Type AC 322 /3 Type AC 322 /1A Type AC 322 /2A Type AC 322 /2AW Type AC 322 /3A See also Chapter 6.2, "Accessories, spare parts and separate components" 10/26 D AC HAWE Hydraulik SE

11 Type AC 603 /3 Type AC 603 /1A Type AC 603 /2A Type AC 603 /2AW Type AC 603 /3A See also Chapter 6.2, "Accessories, spare parts and separate components" HAWE Hydraulik SE D AC /26

12 Type AC 1002 /22 Type AC 1414 /22 Type AC 1002 /2AW Type AC 1414 /2AW Type AC 1002 /2A Type AC 1414 /2A Type AC 1414 /3A Type AC 1002 /3A Type D H AC AC See also Chapter 6.2, "Accessories, spare parts and separate components" 12/26 D AC HAWE Hydraulik SE

13 Type AC 1035 /3 Type AC 1035 /1A Type AC 1035 /2A Type AC 1035 /2AW Type AC 1035 /3A See also Chapter 6.2, "Accessories, spare parts and separate components" HAWE Hydraulik SE D AC /26

14 Type AC 2001 /3A Type AC 2002 /4 Type AC 2002 /3A See also Chapter 6.2, "Accessories, spare parts and separate components" 14/26 D AC HAWE Hydraulik SE

15 Type AC 2825 /1A Type AC 2825 /2A Type AC 2825 /2AW Type AC 2825 /3 Type AC 2825 /3A See also Chapter 6.2, "Accessories, spare parts and separate components" HAWE Hydraulik SE D AC /26

16 5 Assembly, operation and maintenance recommendations 5.1 General notes The hydraulic accumulators are subject to the Pressure Equipment Directive 2014/68/EU. According to Article 3 of the Pressure Equipment Directive 2014/68/EU the following hydraulic accumulators require a declaration of conformity as well as a CE mark: Hydraulic accumulators with a volume > 1 litre and p V > 50 bar litre (section 1.1 a, uids in group 2) Hydraulic accumulators with p V > 10,000 bar litre (section 1.1 b, uids in group 2) Operation is only allowed within the permissible values. The accumulator must only be installed, maintained and repaired by authorised and appropriately trained staff; these tasks are governed by national regulations in Germany, through the Betriebssicherheitsverordnung (BetrSichV) Industrial Safety Regulation, and in the EU through EU Directive 2009/104/EG. The gas pre- lling must be checked regularly. Note The complete hydraulic system has to be discharged prior to any kind of repair. A respective plate (HAWE order No ( )) has to be applied at an easily visible spot on or near-by the accumulator. No modification (welding, soldering, nor mechanical) must be carried out on the accumulator. Only original spare parts are allowed to be used Safety instructions Further information on the technical design of accumulator systems is provided by DIN EN ISO In a nutshell, there must be a facility to release the accumulator pressure on the uid side when servicing is carried out (drain valve and pressure gauge for monitoring purposes). The accumulator must have its own safety valve (valve with TÜV certi ed unit approval). This must limit any momentary overpressure to 10% of the highest permissible pressure. In addition, a warning stating Caution pressure to be released from accumulator before removal must be af xed Legal provisions Hydraulic accumulators are classi ed as pressure vessels under the European Pressure Equipment Directive 2014/68/EU. For hydraulic accumulators, the regulations that apply at the installation location must be adhered to before commissioning and during operation. The operator holds sole responsibility for compliance with the existing regulations. The supplied documents must be kept in a safe place; they will be needed for recurring inspections. 16/26 D AC HAWE Hydraulik SE

17 5.1.3 Transport and storage Caution Comply with the relevant regulations on transportation and safety. Wear protective equipment. Note Accumulators must be stored in a cool, dry place and protected from direct sunlight. Dirt must be prevented from entering the accumulator. If the accumulator is stored over a longer period, it is advisable to reduce the gas pre-load pressure to approx. 10 bar to prevent deformation of the sealing element or separator. 5.2 Intended application This productis exclusively intended for hydraulic applications ( uid engineering). The product demands high technical safety standards and regulations for uid engineering and electrical engineering. The user must observe the safety measures and warnings in this documentation. Essential requirements for the product to function correctly and safely: All information in this documentation must be observed. This applies in particular to all safety measures and warnings. The product must only be assembled and put into operation by quali ed personnel. The product must only be operated within the speci ed technical parameters. The technical parameters are described in detail in this documentation. The operating and maintenance manual of the speci c complete system must also always be observed. If the product can no longer be operated safely: Remove the product from operation and mark it accordingly. It is then not permitted to continue using or operating the product. HAWE Hydraulik SE D AC /26

18 5.3 Assembly information The must only be installed in the complete system with standard and compliant connection components (screw ttings, hoses, pipes, etc.). The hydraulic power pack must be shut down correctly prior to dismounting; this applies in particular to power packs with hydraulic accumulators. Danger Risk to life caused by sudden movement of the hydraulic drives when dismantled incorrectly! Risk of serious injury or death. Depressurise the hydraulic system. Perform safety measures in preparation for maintenance Installation and commissioning Installation Warning Risk of injury due to stored pressure escaping in an uncontrolled manner! Risk of serious injury or death. Prior to all maintenance work, release the pressure in the hydraulic system. 1. Fit the accumulator to the bracket intended for this purpose, if possible route the gas side directing upwards. 2. Fit the required shut-off, drain and safety valves between the accumulator and the hydraulic system. The easiest way to do this is probably using a 'safety block' that contains all the above cap. Initial lling Danger Risk to life due to hydraulic accumulators potentially exploding if they are not lled correctly! Risk of serious injury or death. The maximum operating pressure, lling pressure and temperature range of the hydraulic accumulator must be suitable for the operating conditions. Fill hydraulic accumulators only with N 2 (nitrogen). Only use suitable lling and testing devices. Ensure that the accumulator is suitable for the operating conditions with regard to max. operating pressure, lling pressure and temperature range. Filling with gas: M16x2 mm gas valve with protective cap. 18/26 D AC HAWE Hydraulik SE

19 Filling device for diaphragm accumulators type DFM The pressure of the gas lling of diaphragm accumulators can be checked and altered with the lling device DFM. It is suited for accumulators with thread M28x1.5 and a lling socket screw M8x10. The lling device comes in a box 210x230x80 mm which also contains a pressure gauge As diaphragm accumulators are pressure vessels where the European pressure Vessel Directive applies (for exceptions see there), it has to be made sure that the safety especially against excessive pressure is guaranteed. Usually the accumulators are lled from nitrogen bottles (pressure 200 or 300 bar). It is therefore mandatory to use a pressure reducing valve to make sure that the permissible Permissible operating gauge pressure of the diaphragm accumulator Permissible gas lling pressure of the diaphragm accumulator Permissible display range of the related pressure gauge are not exceeded. Therefore these accumulators must not be lled via adaptors directly from the nitrogen bottle! Testing and lling have to be performed only by trained staff utilizing a pressure reducing valve, pressure gauge and hoses with ttings G 1/4 and G 1/2 DIN 560 (BSPP). Note For order numbers for the lling and testing device, see Chapter 6, "Other information" HAWE Hydraulik SE D AC /26

20 Filling instructions Danger Risk to life due to hydraulic accumulators potentially exploding if they are not lled correctly! Risk of serious injury or death. The maximum operating pressure, lling pressure and temperature range of the hydraulic accumulator must be suitable for the operating conditions. Fill hydraulic accumulators only with N 2 (nitrogen). Only use suitable lling and testing devices. Gas lling: Gas lling valve M28x1.5 mm with protective cover 1. Check that the diaphragm accumulator (1) is completely depressurized on the hydraulic side. Undo and remove the protective cap (2) from the lling port (3) (M28x1.5). Carefully slacken the gas lling screw by a 1/4-turn via an Allan head ( (4) / 6 mm) 2. Close the drain screw (5) at the lling device 6 to its stop. 3. Mount the lling device (6) incl. hose (7) onto the gas port (3) of the diaphragm accumulator (take care that sealing ring (8) is apparent and properly positioned in the groove). Connect hose tting (13) to the outlet port of the pressure reducing valve (15) (bottle valve (16) and shut-off valve (17) have to be still closed) 4. Open the bottle valve (16) and slowly turn the knob (18) until the desired pressure is visible on the pressure gauge (19). Open shut-off valve (17). 5. Twist the toggle (11) until the Allan key (10) engages in the socket head of the lling screw (4). Turn it slowly counter clockwise until pressure balance is audible. Leave shut-off (17) open i.e. let the nitrogen ow, until pressure gauge (12) shows the desired pressure. Close shut-off valve (17) and bottle valve (16) wait until the diaphragm accumulator, cooled down by the lling process, has achieved ambient temperature again. Repeat lling procedure when the gas pressure in the accumulator has dropped. As soon as the desired gas lling pressure is achieved: 6. Make sure that the Allan key (10) is still engaged and rotate toggle (11) clockwise until the lling screw (4) is shut. Open drain screw (5) that the trapped gas can escape from the lling device. 7. Remove lling device 6 from the diaphragm accumulator (1). Tighten the lling screw (4) with 20+5 Nm and reinstall the protective cap (2) on gas port 3 (M28x1.5) 20/26 D AC HAWE Hydraulik SE

21 5.4 Operating instructions Purity and ltering of the hydraulic uid Fine contamination can significantly impair the function of the hydraulic component. Contamination can cause irreparable damage. Examples of ne contamination include: Metal chips Rubber particles from hoses and seals Dirt due to assembly and maintenance Mechanical debris Chemical ageing of the hydraulic uid Note Fresh hydraulic uid from the drum does not always have the highest degree of purity. Under some circumstances the fresh hydraulic uid must be ltered before use. Adhere to the cleanliness level of the hydraulic uid in order to maintain faultless operation. (Also see cleanliness level in Chapter 3, "Parameters"). 5.5 Maintenance information This product is largely maintenance-free. Conduct a visual inspection at regular intervals, but at least once per year, to check if the hydraulic connections are damaged. If external leakages are found, shut down and repair the system. Clean the device surface of dust deposits and dirt at regular intervals, but at least once per year Replacing USIT ring (20) If there is a suspicion of damage or a leak is found, the USIT ring (20) must be replaced; for this purpose the gas lling pressure must be fully relieved (mostly after a very long period of use and/or if there are large pressure differences in the ow of lling gas). To relieve the pressure undertake the rst 3 steps for the gas pressure lling check and then open the drain screw (5) until the pressure gauge (12) indicates the value zero. Once the lling device (6) has been unscrewed, the gas lling screw M8x12 (4) (part number ) can be fully unscrewed and the USIT ring (20) (part number ) can be replaced with a new ring. During this process, ensure that the sealing surface is clean and undamaged. After screwing back in the gas lling screw (4) the lling process as per Chapter 5.3, "Assembly information" for a gas lling pressure change from zero to the required value can be started. HAWE Hydraulik SE D AC /26

22 5.5.2 Checking gas lling pressure 1. Release diaphragm accumulator (1) on the uid side and check the unpressurised state. Unscrew protective cover (2) from gas connection (3) M28x1.5. Carefully loosen gas lling screw (4) by approx. 1/4 rotation using 6 mm hex key (Allen key in accordance with DIN 911). 2. Close the drain screw (5) at the lling device (6) to its stop. 3. Mount the lling device (6) without hose (7) onto the gas port (3) of the diaphragm accumulator (take care that sealing ring (8) is apparent and properly positioned in the groove). Note The check valve (9) installed at the hose side will only work when no hose is connected. 4. Twist the toggle (11) until the Allan key (10) engages in the socket head of the lling screw (4). Turn it slowly counter clockwise until pressure audible enters the lling device. (Note: The gas lling screw (4) can t be completely screwed out while the lling device (6) is mounted. It can be screwed out only as far until a slot apparent on the side can act as passage. The passing gas generates a hissing noise also acting as a warning when the gas lling screw gets opened unintended) The gas lling pressure apparent (conditions: ambient temperature) will be shown at the pressure gauge (12). Close shut-off valve (17) and bottle valve (16) wait until the diaphragm accumulator, cooled down by the lling process, has achieved ambient temperature again. Repeat lling procedure in case the gas pressure in the accumulator has dropped. As soon as the desired gas lling pressure is achieved: 5. Make sure that the Allan key (10) is still engaged and rotate toggle (11) clockwise until the lling screw (4) is shut. Open drain screw (5) that the trapped gas can escape from the lling device. 6. Remove lling device (6) from the diaphragm accumulator (1). Tighten the lling screw (4) with 20+5 Nm and reinstall the protective cap (2) on gas port 3 (M28x1.5) Note Each test sequence causes a small loss of gas lling pressure due to the internal volume of the lling device. It is possible to carry out a gas lling pressure check on the uid side. 22/26 D AC HAWE Hydraulik SE

23 6 Other information 6.1 Notes regarding the lay-out Max. perm. operating pressure Parameters p 0 : Gas lling pressure p 1 : min. working pressure p 2 : max. working pressure The max. perm. operating pressure (p max ) is the pressure to which the accumulator may be maximally exposed. V 0 : Effective volume of the accumulator V 1 : Gas lling volume of the accumulator at p 1 V 2 : Gas lling volume of the accumulator at p 2 SV: Removed/absorbed effective volume between p 1 and p 2 1 Accumulator discharged The diaphragm is forced to the walls of the accumulator by the gas lling. A valve plate at the hydraulic connection prevents any damage of the diaphragm. 2 Accumulator, lower working pressure A residual uid quantity should remain in the accumulator always to prevent any damage to the diaphragm (p 0 < p 1). 3 Accumulator, upper working pressure The volumetric change ΔV apparent between lower and upper working pressure, corresponds to the effective volume to be used: ΔV = V 1 - V 2 Gas pre- lling pressure p 0 (guideline) Pressure storage: approx. 90% of the lower working pressure Pulsation dampening: approx. 60% of the upper working pressure Compensation of temperature in uences Change of state The compression and decompression in a diaphragm type accumulator follow the law of polytrophic change of state for gases. The following has to be distinguished: isotherm changes during slow operations ( (polytrophic exponent n = 1), e.g. when leakage has to be compensated ) Adiabatic changes during quick operations ( (polytrophic exponent n = 1.4, applies to Nitrogen), e.g. when used for dampening circuits ) Calculation V 0 (guideline: V 0 = x ΔV) HAWE Hydraulik SE D AC /26

24 6.2 Accessories, spare parts and separate components Testing device DFM Basic type Display range of the pressure gauge (bar) Upper limit for perm. operating gauge pressure (bar) DFM DFM DFM Mounting brackets HAWE-order No. for the lling and testing device Type D min. - D max. A B C min. - C max. E M x L G H I J K CE M8 x CE M8 x CE M8 x CE M8 x CE M10 x CE M10 x /26 D AC HAWE Hydraulik SE

25 6.2.3 Fittings Coding Description Material number Suitable for /1A Straight tting, /2A Straight tting, /2AW ERMETO GE 16-SR-3/8 EW 16-PS EGE 16-SR-ED /3A Straight tting, /2A Straight tting, /2AW ERMETO GE 16-SM-ED EW 16-PS GE 16-PS/R /3A Straight tting, AC 0725 AC 202 AC 322 AC 603 AC 1035 AC 2825 AC 1002 AC 1414 /3A Straight tting, AC 2002 HAWE Hydraulik SE D AC /26

26 Further information Additional versions Valve bank (nominal size 6) type BA: D 7788 Miniature hydraulic accumulators, type AC: D 7571 Piston type accumulators, type HPS: D 7969 HPS D AC HAWE Hydraulik SE Streitfeldstraße München Postfach München Germany Tel Fax info@hawe.de

Diaphragm accumulator type AC

Diaphragm accumulator type AC Diaphragm accumulator type AC Max. operating pressure pmax: Max. nom. volume VO max: 350 bar 2.8 dm3 Symbol: Product documentation D 7969 AC 04-2014-1.1 HAWE Hydraulik SE - Streitfeldstr. 25 81673 München

More information

Hand pump type CH. Product documentation. 300 bar 8.3 cm 3 /stroke. Operating pressure p max : Displacement volume V max stroke :

Hand pump type CH. Product documentation. 300 bar 8.3 cm 3 /stroke. Operating pressure p max : Displacement volume V max stroke : Hand pump type CH Product documentation Operating pressure p max : Displacement volume V max stroke : 300 bar 8.3 cm 3 /stroke D 7147 CH 04-2018-1.1 by HAWE Hydraulik SE. The reproduction and distribution

More information

Two-stage valve type NE

Two-stage valve type NE Two-stage valve type NE Product documentation Operating pressure pmax: Flow rate Qmax: 700 bar (High pressure) 80 bar (Low pressure) 25 lpm (High pressure) 180 lpm (Low pressure) D 7161 03-2017-1.0 by

More information

Pressure-limiting valve and pre-load valve type MVG, MVE and MVP

Pressure-limiting valve and pre-load valve type MVG, MVE and MVP Pressure-limiting valve and pre-load valve type MVG, MVE and MVP Product documentation Directly controlled Operating pressure pmax: Flow rate Qmax: 700 bar 8 lpm D 3726 02-2016-1.3 by HAWE Hydraulik SE.

More information

Pressure-controlled shut-off valve type CNE

Pressure-controlled shut-off valve type CNE Pressure-controlled shut-off valve type CNE Product documentation Screw-in valve Operating pressure pmax: Flow rate Qmax: 500 bar 30 lpm D 7710 NE 09-2013-1.3 by HAWE Hydraulik SE. The forwarding and reproduction

More information

Pressure-reducing valve type CDK

Pressure-reducing valve type CDK Pressure-reducing valve type CDK Product documentation Screw-in valve Operating pressure pmax: Flow rate Qmax: 500 bar 22 lpm D 7745 07-2013-1.6 by HAWE Hydraulik SE. The reproduction and distribution

More information

Universal Charging and Testing Unit FPU-1

Universal Charging and Testing Unit FPU-1 1. DESCRIPTION 1.1. FUNCTION The charging and testing unit FPU-1 is used to charge accumulators with nitrogen or to check or to change the existing pre-charge pressure in accumulators. For this purpose

More information

Pressure booster combination DPA-CRVZS. Operating instructions a [ ]

Pressure booster combination DPA-CRVZS. Operating instructions a [ ] Pressure booster combination en Operating instructions 8074546 2017-07a [8074548] Original instructions -EN Identification of hazards and instructions on how to prevent them: Danger Immediate dangers which

More information

Pressure reducing valves type CDK

Pressure reducing valves type CDK Pressure reducing valves type CDK No leakage, directly controlled Adjustment: With tools Manually pmax A: pmax P: Qmax: 500 bar 500 bar 22 lpm Product documentation D 7745 07-2013-1.3 HAWE Hydraulik SE

More information

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator Self-operated Pressure Regulators Type 2357-31 Pressure Build-up Regulator with safety function and integrated excess pressure valve Type 2357-31 with non-return unit at port C Ports A and B with soldering

More information

ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS

ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS READ ALL INSTRUCTIONS PRIOR TO INSTALLATION AND OPERATION TO AVOID POSSIBLE INJURY Warning: Always consider any accumulator to contain pressure until proven

More information

Declaration of Conformity as per Directive 97/23/EC

Declaration of Conformity as per Directive 97/23/EC Declaration of Conformity as per Directive 97/23/EC The manufacturer declares that:, 47906 Kempen, Germany Multi-way diverting valves Series 29a and Series 29b, with packing with lever 1. The valves are

More information

Instruction Manual Contact Pressure Vacuum Gauge

Instruction Manual Contact Pressure Vacuum Gauge MS10 Instruction Manual Contact Pressure Vacuum Gauge Table of Contents 1. Safety Instructions 2. Intended Applications 3. Product Description and Functions 4. Installation 5. Commissioning 6. Maintenance

More information

MANUAL. Sesame. Thermoplastic Tank Technologies

MANUAL. Sesame. Thermoplastic Tank Technologies MANUAL Sesame Thermoplastic Tank Technologies INSTALLATION AND USER GUIDE CONTENT 1. GENERAL 3 2. IMPORTANT 3 3. INSTALLATION EXPANSION VESSEL 4 4. USE EXPANSION VESSEL 5 5. AIR CELL REPLACEMENT 5 5.1

More information

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25 Self-operated Pressure Regulators Differential Pressure Regulators (opening) Type 42-20 Type 42-25 Type 42-20 Differential Pressure Regulator Type 42-25 Differential Pressure Regulator Mounting and Operating

More information

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0 Operating Manual LTIA5E Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0 Contents 1. Safety Instructions 2. Conformity to standards 3. Technical data

More information

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN Differential Pressure Regulator Type 45-6 Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN Edition March 2008 Contents Contents Page 1 Design and principle of operation...................

More information

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar EN - english Instructions for installation and operation Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar Dear customer, Thank you for deciding in favour of the METPOINT

More information

Installation, Operating and Maintenance Manual Overflow Regulator Type 94/ 94 E

Installation, Operating and Maintenance Manual Overflow Regulator Type 94/ 94 E Installation, Operating and Maintenance Manual Overflow Regulator Type 94/ 94 E Table of content 1. General information on installation, operating and maintenance instructions 1.1 Hazard notices 1.2 Qualified

More information

Diaphragm Accumulators

Diaphragm Accumulators 1. DESCRIPTION 1.1. FUNCTION Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas is utilised in hydro-pneumatic accumulators for storing fluids.

More information

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar Instruction manual for high purity gas pigtails 200 bar / 300 bar Contents Contents... 2 1. Preface... 3 1.1 Overview... 3 1.2 General... 3 1.3 Intended use... 4 1.4 Personnel requirements... 4 2. For

More information

Declaration of Conformity as per Directive 97/23/EC

Declaration of Conformity as per Directive 97/23/EC Declaration of Conformity as per Directive 97/23/EC The manufacturer declares that:, 47906 Kempen, Germany Continuous, inline sampling valves Series 27f, with packing Operate with either; Star lever, or

More information

Application and Sizing

Application and Sizing Application and Sizing Energy accumulator: It is improbable that an hydraulic system use all of its capacity without interruptions. An hydropneumatic accumulator can store a certain amount of fluid that

More information

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies We reserve the right to make technical changes without notice. Technische Änderungen vorbehalten. Sous réserve de modifications techniques.

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS 0/05 OPERATING INSTRUCTIONS for gas pressure regulators PN0 with integrated slam shut valve (SSV) and integrated limited capacity safety relief valve (RV) MR 25 F0, MR 25 SF0 p e 20 kpa - 0 MPa (0,2-0

More information

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14 15 Elster GmbH Edition 7.15 Translation from the German 519 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Solenoid valve for gas VG VG 15/1 Contents Solenoid valve for gas

More information

Over-center valves type LHT with oscillation damping, zero leakage

Over-center valves type LHT with oscillation damping, zero leakage Over-center valves type LHT with oscillation damping, zero leakage Flow rate Q max = 250 lpm Operation pressure p max = 450 bar See also: o Over-center valve type LHK acc. to D 7100 o Over-center valve

More information

Assembly-, installation- and maintenance instruction manual for bladder accumulators IBV / EBV , top reparable

Assembly-, installation- and maintenance instruction manual for bladder accumulators IBV / EBV , top reparable Page 1 von 8 Assembly-, installation- and maintenance instruction manual for bladder accumulators IBV / EBV 100-575, top reparable Content Seite 0 Legend 2 1 Overview 2 2 Accumulator assembly and installation

More information

Declaration of Conformity as per Directive 97/23/EC

Declaration of Conformity as per Directive 97/23/EC Declaration of Conformity as per Directive 97/23/EC The manufacturer declares that:, 47906 Kempen, Germany Discontinous, inline sampling valves Series 27a and Series 27g, with packing with lever (180 )

More information

Operating and maintenance manual Filter and reducing station Series / 1.0

Operating and maintenance manual Filter and reducing station Series / 1.0 Operating and maintenance manual Filter and reducing station Series 961 04.2017 / 1.0 Original instructions ARCA Regler GmbH. All rights reserved. Cover picture background: Freepik.com ARCA Regler GmbH

More information

1. Preface Important Safety Notes Brief Product Information Product Working Principle Installation Guidelines...

1. Preface Important Safety Notes Brief Product Information Product Working Principle Installation Guidelines... Table of Contents 1. Preface...1 2. Important Safety Notes...1 3. Brief Product Information...3 4. Product Working Principle...5 5. Installation Guidelines...6 6. Startup and Commissioning...8 7. Maintenance

More information

MAINTENANCE AND OPERATING MANUAL

MAINTENANCE AND OPERATING MANUAL MAINTENANCE AND OPERATING MANUAL Cyclone condensate separator Type ASA EN EN Maintenance and operating manual Purpose and appropriate use Dear Customer, thank you for choosing our product. In order to

More information

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity Type 4708-45 Supply Pressure Regulator with increased air capacity Translation of original instructions Mounting and Operating Instructions EB 8546-1 EN Edition March 2016 Note on these mounting and operating

More information

Type BBS-03, BBS-05, BBS-06, BBS-25

Type BBS-03, BBS-05, BBS-06, BBS-25 Type BBS-03, BBS-05, BBS-06, BBS-25 Sterile connection elements Sterile Verbindungselemente Raccords union stériles Operating Instructions Bedienungsanleitung Manuel d utilisation 1. THE OPERATING INSTRUCTIONS

More information

PV4 and PV6 Piston Valves

PV4 and PV6 Piston Valves 1181250/1 IM-P118-05 ST Issue 1 PV4 and PV6 Piston Valves Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning 5. Operation 6.

More information

Pneumatic switch module 3/2-way valve (On/Off) Types P Types FP Function tested for use of the float in Ex-zone 0

Pneumatic switch module 3/2-way valve (On/Off) Types P Types FP Function tested for use of the float in Ex-zone 0 Operating Manual LTIA3E Pneumatic switch module 3/2-way valve (On/Off) Types P Types FP Function tested for use of the float in Ex-zone 0 Contents 1. Safety Instructions 2. Conformity to standards 3. Technical

More information

1200B2 Series Service Regulators. Instruction Manual

1200B2 Series Service Regulators. Instruction Manual 00B Series Service Regulators Instruction Manual 00B Series Service Regulators 0 Elster American Meter 00B Series Service Regulators General Information The 00B Series Service Regulators are available

More information

TEST BENCH SAFETY VALVES ¼ - 5 DN10 DN125

TEST BENCH SAFETY VALVES ¼ - 5 DN10 DN125 TEST BENCH SAFETY VALVES ¼ - 5 DN10 DN125 Model: VC-40-VYC Table of contents 1. - Installing the test bench 1.1.1- Connecting the compressed air / nitrogen source 1.1.2- Maximum test pressure according

More information

Unit 24: Applications of Pneumatics and Hydraulics

Unit 24: Applications of Pneumatics and Hydraulics Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 9 ACCUMULATORS The material needed for outcome 2 is very extensive so there are

More information

for the of and the EM55-1

for the of and the EM55-1 Operating Manua al for the Tapping Points of the EM55-1/EM55-2/EM55-3/ /EM55-4 series and the EE55-1/EE55-2/EE55-3/EE55-4 series EM55-1 Contents Contents... 2 1. Introduction... 3 1.1 General... 3 1.2

More information

MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap

MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap 1250650/6 IM-P125-07 ST Issue 6 MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation

More information

Hydraulic Accumulators with Back-Up Nitrogen Bottles

Hydraulic Accumulators with Back-Up Nitrogen Bottles Hydraulic Accumulators with Back-Up Nitrogen Bottles 1. GENERAL To complete the accumulator range, HYDAC provides a variety of useful accessory products. They guarantee correct installation and optimum

More information

Operating Instructions Hand Test Pump BHP 700

Operating Instructions Hand Test Pump BHP 700 Contents 1. Information on This Operating Instruction 1 1.1 Pictographs Used in This Manual 2 1.2 Exclusion of Liability 2 2. Safety Instructions 2 3. Device Description 3 3.1 Intended Use 3 4. Technical

More information

Airfix D-E-B Installation and operating instructions

Airfix D-E-B Installation and operating instructions www.flamco.nt-rt.ru Airfix D-E-B Installation and operating instructions Dear Customer, With the Airfix D-E-B membrane expansion vessel you have acquired a Flamco quality product. This expansion vessel

More information

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Brass Check Valve RDL

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Brass Check Valve RDL Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU FAS Brass Check Valve RDL Please read these operating instructions carefully to ensure a safe operation and keep the same

More information

Diaphragm Accumulators

Diaphragm Accumulators Diaphragm Accumulators. DESCRIPTION.. FNCTION Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas is utilised in hydraulic accumulators for storing

More information

Safety. Operating instructions Gas pressure regulators 60DJ, J78R, GDJ DANGER WARNING. Contents CAUTION Edition 12.10

Safety. Operating instructions Gas pressure regulators 60DJ, J78R, GDJ DANGER WARNING. Contents CAUTION Edition 12.10 ... Edition.0 D GB F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Gas pressure regulators 0DJ, J78R, GDJ Translation from the German 008 009 Elster GmbH Contents Gas pressure

More information

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. AWA Change-over Valve

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. AWA Change-over Valve Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU AWA Change-over Valve Please read these operating instructions carefully to ensure a safe operation and keep the same for

More information

Translation of the original Operating Instructions for HKS rubber compensators

Translation of the original Operating Instructions for HKS rubber compensators Because of their flexible elements and mechanisms, HKS rubber compensators are susceptible to damage of all types and adverse loads in operation. For reliable operation of a compensator and, thus, the

More information

Manual Actuated Boiler Blowdown Valves

Manual Actuated Boiler Blowdown Valves Manual Actuated Boiler Blowdown Valves Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Operation 5. Maintenance 6. Spare parts p.1 1. Safety

More information

Diaphragm Accumulators

Diaphragm Accumulators Diaphragm Accumulators HYDAC Diaphragm Accumulators Index Page 1. Description 3 Introduction 3 Construction 3 2. Applications 4 3. Technical Data 6 Operation 6 Technical Specifications 6 Temperature Effect

More information

Operating Instructions - Rescue Equipment. RAM Support LRS-T EN Edition (translation of the original operating instructions)

Operating Instructions - Rescue Equipment. RAM Support LRS-T EN Edition (translation of the original operating instructions) Operating Instructions - Rescue Equipment RAM Support LRS-T 174190085 EN Edition 08.2017 (translation of the original operating instructions) Content Page 1. Hazard classes 3 2. Product safety 4 3. Intended

More information

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10 LK product no: PCS 1-10 Article no: 74503 Revision:8 Article no: 74503 Revision: 8 2 (23) Contents 1. General information... 5 2. Safety precautions... 5 2.1 Significance of symbols... 5 2.2 Explanatory

More information

Pressure reducing valve, pilot operated

Pressure reducing valve, pilot operated Pressure reducing valve, pilot operated RE 26928/09.07 Replaces: 10.97 1/8 Type 3DR Size 16 Component series 5X Maximum operating pressure 250 bar Maximum flow 220 l/min H5844 Table of contents Content

More information

Installation, Operating & Maintenance Instructions. Variable leak valve with manual actuator. Series 590 DN 16 mm (I. D. ⅝") E

Installation, Operating & Maintenance Instructions. Variable leak valve with manual actuator. Series 590 DN 16 mm (I. D. ⅝) E Installation, Operating & Maintenance Instructions Variable leak valve with manual actuator DN 16 mm (I. D. ⅝") This manual is valid for the following product ordering numbers: 59024-. E01 -... Sample

More information

Siphon vessel / Priming aid

Siphon vessel / Priming aid Manufacturer: sera GmbH sera-straße 1 34376 Immenhausen Germany Tel.: +49 5673 999-00 Fax: +49 5673 999-01 info@sera-web.com Keep the operating manual for future use! Record the exact type and serial number

More information

MF2M Monnier Miniature Compressed Air Filter

MF2M Monnier Miniature Compressed Air Filter 5040050 / 2 IM-P504-02 CH Issue 2 MF2M Monnier Miniature Compressed Air Filter Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation and commissioning

More information

Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap

Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap 0509950/2 IM-P050-21 CH Issue 2 Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation and

More information

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot. Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com P5513 Pneumatic Comparison Test Pump Users Manual PN 3963372 November 2010 2010 Fluke Corporation. All

More information

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide Pilot HON 62 Entwurf Product information serving the gas industry worldwide Pilot HON 62 Application, characteristics Application Pilot for the gas pressure regulator HON 02 Pilot for outlet pressure control

More information

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions 4059051/3 IM-P405-48 EMM Issue 3 KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4.

More information

P2* MODULAR SUBPLATES FOR ISO (CETOP 03) VALVES

P2* MODULAR SUBPLATES FOR ISO (CETOP 03) VALVES 52 000/110 ED This series of modular subplates has been designed to make hydraulic circuits and can be used directly on power packs or on any other section of the machine. The subplates are assembled by

More information

Pressure maintenance valve SDV-P / SDV-P-E

Pressure maintenance valve SDV-P / SDV-P-E Translation of the original manual Pressure maintenance valve SDV-P / SDV-P-E Assembly and Operating Manual Superior Clamping and Gripping Imprint Imprint Copyright: This manual remains the copyrighted

More information

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator. RS(H)10,15 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to

More information

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly. Components preparation and pressure adjustment ABP Overview ABP is a component that enables boosting by s only up to twice primary pressure (.0MPa max.) in combination with using air tank but not using

More information

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Knob Adjustment)

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Knob Adjustment) 3810050/5 IM-P381-01 CH Issue 5 SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Knob Adjustment) Installation and Maintenance Instructions 1. Safety information 2. Use 3.

More information

Diaphragm Accumulators

Diaphragm Accumulators Diaphragm Accumulators. DESCRIPTION.. FNCTION Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas is utilised in HYDAC diaphragm accumulators

More information

3-Way Pressure-Reducing Cartridge, Size 2 4

3-Way Pressure-Reducing Cartridge, Size 2 4 -Way Pressure-Reducing Cartridge, Size 2 Q max = 2 l/min, p max = 25 bar Spool-type design, direct acting, with manual adjustment 1 Description Compact construction for cavity type AM /- UNF to Bucher

More information

Pressure reducing valve, direct operated

Pressure reducing valve, direct operated Electric Drives and Controls Table of contents Hydraulics Pressure reducing valve, direct operated Model ZDR 6 D Nominal size 6 Series 4X Maximum operating pressure 20 bar (3050 PSI) Maximum flow 50 L/min

More information

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies Type 2000 INOX 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies Quickstart English Deutsch Français Contents 1 QUICKSTART... 2 2 CONTACT ADDRESS... 2 3 INTENDED USE...

More information

Series AMJ. Drain Separator for Vacuum

Series AMJ. Drain Separator for Vacuum CAT.E 827- Drain Separator for Vacuum Remove water droplets from air by simply installing in vacuum equipment connection lines. Effective for removing water droplets from the air sucked into vacuum pumps

More information

Ball valve. Operating instructions for series. Version BA Print-No TR MA DE Rev001

Ball valve. Operating instructions for series. Version BA Print-No TR MA DE Rev001 Ball valve Operating instructions for series Version BA-2016.02.05 Print-No. 300 587 TR MA DE Rev001 We reserve the right to make technical changes. Read carefully before use. Save for future use. ASV

More information

HPB25 Hydraulic Paving Breaker

HPB25 Hydraulic Paving Breaker INSTRUCTION MANUAL HPB25 Hydraulic Paving Breaker Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Register this product at www.greenlee.com

More information

Hydraulic Piston Accumulators

Hydraulic Piston Accumulators Hydraulic Installation All accumulators shipped from the factory will be pre-charged to a nominal pressure in order to seat the piston on the hydraulic cap. In this case the precharge will not be listed

More information

Operation Manual Piston Sensed Gas Pressure Regulators

Operation Manual Piston Sensed Gas Pressure Regulators 687 Technology Way Napa, CA 94558 Phone: (707) 259-0102 FAX: (707) 259-0117 www.aptech-online.com Operation Manual Piston Sensed Gas Pressure Regulators (Models KT9, KT10, Welded KT10, KT12) Table of Contents:

More information

Operating manual. LINDOFLAMM Acetylene special burner LF-H series.

Operating manual. LINDOFLAMM Acetylene special burner LF-H series. Operating manual. LINDOFLAMM Acetylene special burner LF-H series. 02 Operating manual. LINDOFLAMM acetylene special burner. This operating manual is valid for the following models LF-H-4, 6, 8 and 16:

More information

Check valve hydraulically pilot operated

Check valve hydraulically pilot operated Check valve hydraulically pilot operated RE 6/7.5 Replaces:. / Types SV and SL Nominal sizes to Component series X Maximum operating pressure 5 bar Maximum flow 55 l/min H555 Overview of contents Contents

More information

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves. Powers Controls RV 201 Pressure Reducing Valves Description Features Product Numbers Dual Pressure PRV Technical Instructions Document No. 155-049P25 RV 201-1 Single Pressure PRV The RV 201 Pressure Reducing

More information

Leak free Pipe Rupture Valve for Excavators

Leak free Pipe Rupture Valve for Excavators Leak free Pipe Rupture Valve for xcavators Series motion and progress Reference: 3 P 9575 1/11.6 Classification: 43.325.355...325.35 1/17 Contents Page 1 General description................................................................

More information

Un-Pressurized Orefice Fittings FIO EZ. Parts List and Operation Instructions TECHNICAL MANUAL. Dn 2-6 Class Lbs

Un-Pressurized Orefice Fittings FIO EZ. Parts List and Operation Instructions TECHNICAL MANUAL. Dn 2-6 Class Lbs Un-Pressurized Orefice Fittings FIO EZ Parts List and Operation Instructions TECHNICAL MANUAL Dn 2-6 Class 150-600 Lbs US US 2 FIO EZ - MT 108-US - 05-2016 FIO EZ Important Instructions US Pietro Fiorentini

More information

Hydraulic Piston Accumulators

Hydraulic Piston Accumulators Ride Control Engineering Services PWCE Extendavator Paul Wever Construction Equipment Co., Inc. P.O. Box 85 401 Martin Drive Goodfield, IL 61742-0085 Phone (309) 965-2005 Fax (309) 965-2905 1-800-990-PWCE

More information

/ Air Line Kit AL - M1202. / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651

/ Air Line Kit AL - M1202. / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651 / Air Line Kit AL - M1202 / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651 002 1 Thank you for purchasing the Air Line Kit " AL - M1202 ". This Air Line Kit is designed to adjust the air supply

More information

Declaration of Conformity as per Directive 97/23/EC and Manufacturer s Declaration as per Directive 98/37/EC

Declaration of Conformity as per Directive 97/23/EC and Manufacturer s Declaration as per Directive 98/37/EC Declaration of Conformity as per Directive 97/23/EC and Manufacturer s Declaration as per Directive 98/37/EC The manufacturer declares that:, 47906 Kempen, Germany Continuous, PFA-lined, inline sampling

More information

Types 749B and R130 Changeover Manifolds

Types 749B and R130 Changeover Manifolds Instruction Manual MCK-1179 Types 749B and R130 June 2012 Types 749B and R130 Changeover Manifolds TYPE HSRL-749B TYPE 64SR/122 TYPE R130/21 TYPE 749B/21 Figure 1. Changeover Manifolds and Regulator Assemblies

More information

Bladder Damper PP/PVC

Bladder Damper PP/PVC Operating instructions Bladder Damper PP/PVC EN Please carefully read these operating instructions before use. Do not discard. The operator shall be liable for any damage caused by installation or operating

More information

Airfix. Flamco. Flamco. Pressure expansion vessels for sanitary appliances and potable water systems AIRFIX A AIRFIX D AIRFIX D-E

Airfix. Flamco. Flamco. Pressure expansion vessels for sanitary appliances and potable water systems AIRFIX A AIRFIX D AIRFIX D-E AIRFIX EXPANSION VESSELS Flamco Airfix Pressure expansion vessels for sanitary appliances and potable water systems AIRFIX A AIRFIX AIRFIX -E Flamco Edition 2005 / EXP Flamco Flamco offers you a wide choice

More information

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Type Type Differential Pressure Regulators (opening)

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Type Type Differential Pressure Regulators (opening) Self-operated Pressure Regulators Type 42-20 Type 42-25 Differential Pressure Regulators (opening) Translation of original instructions Type 42-20 Differential Pressure Regulator Type 42-25 Differential

More information

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10 / ED VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES OPERATING PRINCIPLE The VPPL are variable displacement axial-piston pumps with variable swash plate, suitable for applications

More information

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Manual Brass Shut-Off Valve DN10 through DN22

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Manual Brass Shut-Off Valve DN10 through DN22 Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU FAS Manual Brass Shut-Off Valve DN10 through DN22 Please read these operating instructions carefully to ensure a safe operation

More information

Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

Overview of types.   T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2) Technical data sheet R3015-..-..-B2 / R3020-..-..-B2 Characterised control valves, 6-way, with internal threads Two sequences (cooling/heating) With a rotary actuator 90 Water-side switching or modulating

More information

1800C and 1800C-HC Series Service Regulators

1800C and 1800C-HC Series Service Regulators 1800C and 1800C-HC Series Service Regulators Installation Instructions www.elster-americanmeter.com General Information: The 1800C and 1800C-HC Regulators are available as Full Capacity Internal Relief

More information

STAUFF Accumulators Accessories

STAUFF Accumulators Accessories Local Solutions For Individual Customers Worldwide STUFF ccumulators Clamps & Supports 28 Safety Blocks 30 Burst Discs 34 Fuse Discs 35 Replacement Back-up Bottles 36 Clamps & Supports ccumulator Clamps

More information

2-Port Seat Valves with Flange, PN 16

2-Port Seat Valves with Flange, PN 16 4 40 2-Port Seat Valves with Flange, PN 6 VVF4... Grey cast iron EN-GJL-250 valve body DN 50...50 k vs 9...00 m /h Can be equipped with SQX- electromotoric or SKD...-, SKB...- or SKC...- electrohydraulic

More information

Flowmeter. Original operating manual DFM

Flowmeter. Original operating manual DFM Flowmeter Original operating manual Series DFM 165 350 Version BA-2016.08.09 EN Print-No. 300 458 TR MA DE Rev002 ASV Stübbe GmbH & Co. KG Hollwieser Straße 5 32602 Vlotho Germany Phone: +49 (0) 5733-799-0

More information

FV Flash Vessel Installation and Maintenance Instructions

FV Flash Vessel Installation and Maintenance Instructions 4041050/5 IM-P404-10 EMM Issue 5 FV Flash Vessel Installation and Maintenance Instructions 1. Safety information 2. Specific product safety information 3. Product information 4. Installation 5. Commissioning

More information

COSASCO 3600 PSI SINGLE ISOLATION SERVICE VALVE (FR) MAINTENANCE

COSASCO 3600 PSI SINGLE ISOLATION SERVICE VALVE (FR) MAINTENANCE COSASCO 3600 PSI SINGLE ISOLATION SERVICE VALVE (FR) MAINTENANCE Rohrback Cosasco Systems, Inc. 11841 E. Smith Avenue Santa Fe Springs, CA 90670 Tel: (562) 949-0123 (800) 635-6898 Fax: (562) 949-3065 www.cosasco.com

More information

BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications

BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications 1800350/6 IM-P180-12 ST Issue 6 BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications Installation and Maintenance Instructions 1. Safety information 2. General

More information

ATS430 turbidity sensor Retractable insertion assembly

ATS430 turbidity sensor Retractable insertion assembly A MEASUREMENT & ANALYTICS INSTRUCTION ATS430 turbidity sensor Retractable insertion assembly Measurement made easy 1 Introduction This publication details installation procedures for the retractable insertion

More information

AIR HAMMERS MODEL NO: CAT138/CAT139 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: / GC064

AIR HAMMERS MODEL NO: CAT138/CAT139 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: / GC064 AIR HAMMERS MODEL NO: CAT138/CAT139 PART NO: 3120152 /3120153 OPERATING & MAINTENANCE INSTRUCTIONS GC064 INTRODUCTION Thank you for purchasing this CLARKE Air Hammer. Before attempting to use this product,

More information

Copyright, 2005 GPM Hydraulic Consulting, Inc.

Copyright, 2005 GPM Hydraulic Consulting, Inc. Troubleshooting and Preventive Maintenance of Hydraulic Systems Learning to Read the Signs of Future System Failures Instructed by: Al Smiley & Alan Dellinger Copyright, 2005 GPM Hydraulic Consulting,

More information