Vibro -LE Manual. Please be sure to read this entire user manual prior to use of the equipment. Please read all safety instructions carefully.

Size: px
Start display at page:

Download "Vibro -LE Manual. Please be sure to read this entire user manual prior to use of the equipment. Please read all safety instructions carefully."

Transcription

1 Vibro -LE Manual Please be sure to read this entire user manual prior to use of the equipment. Please read all safety instructions carefully. This user manual is part of the product. Keep it in a safe place for future reference. Replacement manuals can be downloaded from our Webpage at: 1

2 1. Description a. Introduction b. Validity c. Symbols 2. System 3. Safety a. Parts list b. System description a. Intended use b. Personnel Qualification c. Media d. Pressurized Components e. Leaking fluids f. Sharp objects g. Moving parts h. Personal protective equipment i. Accessories and spare parts 4. Operation a. Introduction b. General Guidelines - Process c. Batch operation with the SANI Membranes Standard Batch Feed System d. Continuous operation with the SANI Membranes Standard Continuous Feed System e. CIP operation f. Homogenization of viscous/high concentration media in the retentate chamber 5. Assembly a. Assembly of batch production system with SANI Membranes Standard Batch Feed System b. Assembly of continuous production system with SANI Membranes Standard Continuous Feed System c. Assembly and removal of the Vibration Motor 6. Membrane Exchange a. Disassembly of the Membrane Assembly b. Assembly of the Membrane Assembly 7. Technical Data 8. Conformity 2

3 1. Description Please be sure to read this entire user manual prior to use of the equipment. Please read all safety instructions carefully. This user manual is part of the product. Keep it in a safe place for future reference. a. Introduction The Vibro -LE is a portable benchtop filtration system for continuous microfiltration and ultrafiltration applications. The Vibro -LE holds 0,35 m 2 membrane area in a rigid Free Flow Plate element. The patented Vibro -LE vibrates the rigid Free Flow Plate membrane element relative to the media. Thus, creating turbulence in the media on the membrane surface. The turbulence created on the membrane surface ensures a fast and low fouling filtration process without the need of conventional tangential crossflow. The Vibro -LE is perfect for process development, small batch production and other applications where traditional dead-end filtration devices gives up and tangential crossflow solutions are few and expensive. Disruptive in size, simplicity and process allowing full observation of media and membrane surfaces at all times, no dead volumes, easy to clean, easy to service and simple to operate. The Vibro -LE is exceptional for gaining insight into the filtration process, for selecting the right membranes and for filtering almost any media with continuous membrane filtration in a laboratory or even small production scale. The Vibro -LE can filtrate the most demanding media with high viscosity, high solid loads and even high particulates with unpreceded results less fouling, higher flux, higher degree of up-concentration. The Vibro -LE can be operated as vibration driven deadend filtration, where the media is concentrated in the retentate chamber and discharged at end of operations. The vibrating membrane will keep fouling levels to a minimum and give you unimpeded fluxes and retentate concentrations. The Vibro -LE can also be operated as continuous filtration, with a feed pump feeding in media and continuously discharging of permeate and retentate. The vibrating membrane will diminish fouling and create a higher flux than conventional cross flow filtration. A slow circulation pump with minimum shear can be mounted for homogenization of the retentate if necessary. The membrane is fused to the surface of the Free Flow Plates by welding. The Free Flow Plates are then welded together forming the Free Flow Plate Laboratory Element (HPL) with all its functionalities. The HPL configuration with 1.7 mm free flow channels allows for filtration with no need for pre-filtration even for high solids loading and high viscosity media. The HPL has an integrated and open permeate channel design. Thus, the retentate as well as the permeate can be drained completely - no product loss. The HPL can be configured with virtually any commercially available MF or UF membrane. The pressure chamber is made in clear polymeric material and operates at up to 4 bar at room temperature. The clear plastic gives excellent visibility of the membrane during operation and cleaning. All media contacting parts are in durable polymeric materials or stainless steel. The Vibro -LE can conform to FDA materials if required. b. Validity This manual applies to the Vibro-L in the following versions: Vibro-LE This manual applies to the Vibro-LE in combination with the following components: Free Flow Plate Laboratory Elements (HPL) from SANI Membranes with all MF and UF membranes available at any time. Standard Batch Feed System from SANI Membranes Standard Continuous Feed System from SANI Membranes 3

4 c. Symbols As warning of danger, all text statements in these instructions to be noted will be marked as follows: WARNING This symbol denotes a possible danger with medium risk that death or (severe) injury may result if it is not avoided. CAUTION This symbol denotes a possible danger with a low risk that moderate or minor injury may result if it is not avoided. ATTENTION This symbol denotes a danger with low risk of damage to property if not avoided. 4

5 2. System a. Parts list Base plate Membrane Assembly including mechanic Vibration Motor, Membrane Chamber, Permeate Outlets and Chamber Sides Leaf Spring Set Rubber Gasket Set 1 set of fittings for the air cushion chambers 1 Free Flow Plate Laboratory Element (HPL) b. System description The Membrane Chamber has 2 media inlets at the top and 2 media outlets at the bottom, all with 1/8 thread for mounting fittings. The Membrane Chamber has 2 circular holes running through it for mounting the membrane element rigidly with the Permeate Outlets. 1 permeate outlet has a ¼ thread for fittings and the other Permeate Outlet is a blind with no fluid connection to the permeate. The Membrane Chamber also have two rectangular openings in each end, where impermeable rubber gaskets are placed to divide the media from the Air Cushions in the Chamber Sides. The Chamber Sides are mounted on the Membrane Chamber ends with impermeable rubber gaskets in-between the Chamber Sides and the Membrane Chamber. The Air Cushions are made up by the rubber gaskets and the cavities in the Chamber Sides. The Air Cushions should be filled with pressurized air of the same pressure as the media in the Membrane Chamber (e.g. by using one of SANI Membranes Vibro-LP feed systems). The Chamber Sides are fitted with push-in fittings for 6mm flexible tubing for pressurized air supply. The Chamber Sides also have slits for the leaf springs connecting them with the base plate. 5

6 The mechanic Vibration Motor is mounted on Chamber Side 2 with 4 bolts running through the chamber side. The Membrane Assembly is defined as the entire vibrating unit mounted to the base plate through the Leaf Springs. The Vibration Motor delivers the vibrating motion of the entire Membrane Assembly and the pressure balanced Air Cushions makes the media stationary inside the Membrane Assembly. The turbulence created on the membrane surfaces is optimal for low fouling filtration applications. The standard way to run the Vibro-LE is to feed media in through one of the feed inlets in the top of the Membrane Chamber, the other inlet is only used to vent the air out of the system when it is filled with media. The permeate is taken out through the bottom permeate outlet and the retentate is bleeded out of the retentate outlet in the bottom opposite the feed inlet used. The other retentate outlet is usually not used and therefor plugged. SANI Membranes have made feed systems dedicated for use with the Vibro-LE, but you can also make your own feed system for your specific application. The most important things to remember when designing a feed system, is that it should deliver an air pressure for the Air Cushions at the same pressure as in the media in the Membrane Chamber, and that it should have a CE approved safety valve of maximum 4 bars. When You operate under 1 bar you can use a special balloon gasket (not included) instead of the polymer gasket and plug the Air Cushion inlet. See more examples of use in the Operation section. 6

7 3. Safety Please be sure to read this entire user manual prior to use of the equipment. Please read all safety instructions carefully. This user manual is part of the product. Keep it in a safe place for future reference. a. Intended use The Vibro-LE is a manually operated benchtop filtration system for MF and UF filtration. The user should read and understand this manual before use. The Vibro-LP is intended for use in a laboratory setting in an industrial, research or teaching facility. The Vibro-LE is intended to filter media and can only be used with a 0,35 m 2 HPL membrane element from SANI Membranes. The Vibro-LE can only be used together with a feed system with a CE approved safety valve set to maximum 4 bars. The feed system could be the Standard Batch Feed System or the Standard Continuous Feed System from SANI Membranes. Other feed systems can be used if they have a CE approved safety valve of maximum 4 bars. The Vibro-LE is NOT suited for use in explosive environments. WARNING This instruction manual is part of the Vibro-LE. The Vibro-LE is intended exclusively for use in accordance with this instruction manual. The Vibro-LE must only be used for intended use, the following are examples of improper use WARNING: Unauthorized modifications and technical changes to the Vibro-LE are improper use. Operation outside the permissible physical conditions given in this document (e.g. temperature, pressure, chemical vapors etc.) and given in the specification sheet for the HPL membrane element used. Installation of unauthorized items on the Vibro-LE. Connection of unsuited devices to the Vibro-LE (e.g. unsuited feed systems). Use of media with biological materials in Safety Classes 2 and 3. Use of flammable or potentially explosive substances. Filtration of unstable media. Use of media which are incompatible with PP, PVC, Stainless Steel, PDMS or other materials in the Vibro-LP, HPL membrane element or feed system used. b. Personnel Qualification All personnel operating the Vibro-LE must have read this instruction manual thoroughly and be skilled in the art of pressurized filtration. All personnel operating the Vibro-LE should be used to conduct themselves in a laboratory environment and have passed mandatory safety courses etc. Students operating the Vibro-LE must be instructed thoroughly by skilled teachers or other skilled personnel in proper use of the Vibro-LE. c. Media The media used in the system can be dangerous to handle and cause personnel injuries or equipment damage when not handled correctly. The operator should always seek the applicable safety information for the media to be filtered (e.g. handling and storage and conduct in emergency situations). WARNING Personal safety equipment should always be worn when applicable (e.g. safety googles, safety gloves etc.). WARNING Do Not use media with biological materials in Safety Classes 2 and 3. WARNING 7

8 Do Not use flammable or potentially explosive substances. WARNING Do Not use unstable media where concentration changes might start chemical reactions within the media. WARNING The operator should always make sure that the media to be filtered is compatible with the materials in fluid connection in the Vibro-LE (PP, PVC, Stainless Steel and PDMS) and the feed system used. ATTENTION d. Pressurized Components If the pressure needed for the Membrane Assembly is generated by an external feed system (not included), then the Membrane Assembly, the external feed system and the tubing and fittings between the external feed system and the Membrane Assembly are a separate pressurized system. The system must be operated at maximum 4 bar and the external feed system must have a CE approved safety valve set at maximum 4 bar. Parts of the system can burst if they are subjected to pressures over 4 bar. WARNING e. Leaking fluids If the fluid system is leaking, liquid spill can cause a serious health danger depending on media. The operator should always seek the applicable safety information for the media to be filtered (e.g. handling and storage and conduct in emergency situations). Personal safety equipment should always be worn when applicable (e.g. safety googles, safety gloves etc.). WARNING If the fluid system is leaking, liquid spill to the floor can cause a slipping hazard. CAUTION f. Sharp objects The leaf springs are sharp objects. Be very careful not to get in contact with the leaf springs when assembling or disassembling the system. CAUTION g. Moving parts Body parts can be crushed when they come into contact with moving parts, e.g. the Membrane Assembly. This can lead to injuries. WARNING Lose hair or lose clothing parts can be caught in moving parts and cause injuries. CAUTION The Vibro-LE must be placed on a horizontal non-slippery surface as the vibrating movement can otherwise make the Vibro-LE move doing operation and cause injuries if it falls to the floor. CAUTION h. Personal protective equipment Mandatory personal protective equipment to protect against risks arising from the equipment or the material being processed: Tight-fitting work clothing - Protects against being caught by moving parts. CAUTION Head covering - Protects hair from being pulled into moving parts. CAUTION Safety glasses - Protects against substances leaking under high pressure, splashing liquids etc. WARNING Safety shoes - Protects against injuries to the feet caused by mechanical effects. CAUTION i. Accessories and spare parts The Vibro-LE can only be used together with a feed system with a CE approved safety valve set to maximum 4 bars. The feed system could be the Standard Batch Feed System or the Standard Continuous Feed System from SANI Membranes. Other feed systems can only be used if they have a CE approved safety valve of maximum 4 bars. 8

9 The use of unsuitable accessories, consumables and spare parts can be hazardous and have the following consequences: Severe personnel injury WARNING Damage to the device WARNING Malfunctions of the device ATTENTION Device failure ATTENTION Only use accessories, consumables and spare parts that are in technically perfect condition. The use of accessories, consumables and spare parts not approved by SANI Membranes is the sole responsibility of the operator. 9

10 4. Operation a. Introduction The Vibro-LE is simple to operate and gives you a perfect continuous filtration, if you remember to feed in air to the air cushions with the same pressure as the feed media has. Sani Membranes has developed feed systems for this purpose, but you can also make your own feed system for the Vibro-LE. When You operate under 1 bar you can use a special balloon gasket (not included) instead of the polymer gasket and plug the Air Cushion inlet. The chamber is filled by feeding media carefully through the Feed inlet (4) with the Retentate Outlet (7) closed and the Airvent (6) and Permeate Outlet (5) open. Close the Airvent (6) when the media has covered the membrane completely. Air pockets in top of the chamber has no effect on the filtration if the entire membrane is covered by media. Start the Vibration Motor at 4 bar just after filling the chamber with media and turn it off just after emptying the chamber for media. Severe fouling will occur if you stop the vibration motor with pressurized media in the chamber. The pressure is regulated up to the operating pressure and retentate is bleeded out through the Retentate Outlet (7). The amount of retentate to bleed out is calculated from your desired up-concentration degree and the amount of permeate produced (e.g. to up-concentrate your feed to double concentration you need to bleed out the same amount of retentate as the amount of permeate produced). When the filtration process is finished, take of the feed pressure and empty the system for retentate and permeate. Clean the system with the appropriate CIP protocol for your membrane and application and finish the CIP by filling the system with an appropriate storing solution for your membrane and application. Attention: Organic membranes must never be allowed to dry out after initial wetting. See storage after CIP. Attention: Always maintain a positive trans membrane pressure when operating Your Vibro-LE. Permeate Outlet (5) must be kept open when the unit is in operation. Pressure guidelines during operation: a) Avoid operating the unit at excessive flux leading to fast and high fouling of the membranes. b) Recommended trans membrane pressure for microfiltration is bar. c) Recommended trans membrane pressure for ultrafiltration is 1-3 bar. 10

11 b. General Guidelines Process 1. Maintain a positive trans membrane pressure (min 0,02 bar) when vibration mode is on and keep the permeate drain open at all times. 2. Maintain a retentate flow to avoid dead-end type filtration. A suitable retentate flow is normally +3 L/h but it is application dependent. 3. When filtering media with high viscosity or high solids load a mix flow of l/h should be established from corner to corner to avoid severe fouling. 4. When MF filtering media with high solids load, the mix flow and vibration must be initiated as soon as the unit is filled to avoid severe fouling. Microfiltration (0 1 bar) 1. Keep a very low trans membrane pressure: 0,02 to 0.2 bar often gives the best long-time results. 2. The flux can be very high and easily result in severely fouled areas in the vibro unit. Reduce the flux by lowering the trans membrane pressure and let more retentate out to avoid severe fouling. 3. Air Cushion exits can be plugged off or their pressure can be balanced with the feed pressure as in UF Filtration. Examples of Microfiltration Process Configurations: MF batch mode with Standard Batch Feed System plug flow Simple configuration for viscosities up to cream level Feed flow and trans membrane pressure is regulated with the air pressure The concentration factor is regulated with the retentate valve (flow of permeate measured against flow of retentate) MF batch mode with Standard Batch Feed System and mix pump high solids or high viscosity Configuration for high viscosity or high solids load; retentate must be kept fluid. Feed flow and trans membrane pressure is regulated with air pressure The concentration factor is regulated with the retentate valve (flow of permeate measured against flow of retentate) 11

12 Continuous MF mode with feed pump plug flow Configuration for viscosities up to cream level Feed flow and trans membrane pressure is regulated with the speed of the feed pump. The concentration factor is regulated with the retentate valve (flow of permeate measured against flow of retentate) Continuous MF mode with feed and mix pump high solids or high viscosity Configuration for high viscosity or high solids load; retentate must be kept fluid. Feed flow and trans membrane pressure is regulated with the speed of the feed pump. The concentration factor is regulated with the retentate valve (flow of permeate measured against flow of retentate) Continuous MF mode Concentration in tank - high solids or high viscosity possible Configuration for high viscosity or high solids load with concentration in feed tank; retentate must be kept fluid. Feed flow and trans membrane pressure is regulated with the speed of the mix flow pump and retentate valve The concentration factor in the retentate is calculated from the amount of permeate collected and the initial feed volume 12

13 Ultrafiltration (1 4 bar) 1. Make sure that the system pressure does not exceed 4 bar (3 bar at temperatures above 35 C) a 4 bar safety valve is required! The batch tank from Sani Membranes Standard Batch Feed System is equipped with a 4 bar safety valve. Examples of Ultrafiltration Process Configurations: UF batch mode with Standard Batch Feed System plug flow Simple configuration for viscosity up to cream level Feed flow and trans membrane pressure is regulated with air pressure Vibro cushion pressure is regulated with the air pressure in the feed tank The concentration factor is regulated with the retentate valve (flow of permeate measured against flow of retentate) UF batch mode with Standard Batch Feed System and mix pump high solids or high viscosity Configuration for high viscosity or high solids load; retentate must be kept fluid. Vibro cushion pressure is regulated with the air pressure in feed tank Feed flow and trans membrane pressure is regulated with air pressure The concentration factor is regulated with the retentate valve (flow of permeate measured against flow of retentate) Continuous UF mode with feed pump plug flow Configuration for viscosity up to cream level Feed flow and trans membrane pressure is regulated with the speed of the feed pump. The Vibro cushion pressure is regulated by a hydrophore The concentration factor is regulated with the retentate valve (flow of permeate measured against flow of retentate) 13

14 Continuous UF mode with feed and mix pump high solids or high viscosity Configuration for high viscosity or high solids load; retentate must be kept fluid. The Vibro cushion pressure is regulated by a hydrophore Feed flow and trans membrane pressure is regulated with the speed of the feed pump The concentration factor is regulated with the retentate valve (flow of permeate measured against flow of retentate) Normal CIP for all Process Configurations (MF and UF): Water flushes, buffer flushes or CIP cleaning must be performed after each run with media in the Vibro -LE. The appropriate cleaning method must be found for each membrane and membrane application by the user. A typical CIP routine for operation with organic material could consist of: Drain Flush through with warm water Drain Lye, max 55 C at ph 11.5 for min. Drain Flush with water for 10 min. Drain Acid at ph 1.5 for min. Drain Flush with water for 10 min. Drain Leave filled with water or water + preservation or 20% alcohol. To adjust timing adjust flow, adjust trans membrane pressure and retentate flow. Ensure around 50/50 flow through the permeate and the retentate outlet. 14

15 c. Batch Operation with the SANI Membranes Standard Batch Feed System 1. Start with a fully assembled and drained Vibro -LE system as shown above with all valves and regulators closed. 2. Fill the feed tank with your feed solution (maximum 7 L). 3. Open the Airvent (6), the Feed Inlet valve (4) and the Permeate Outlet valve (5). 4. Fill the retentate chamber by opening the Feed Pressure Regulator (1) slightly. Follow the filling of the retentate chamber visually and close the Airvent (6) when the retentate chamber is full. 5. Start the vibration motor. 6. Regulate the feed pressure to the desired operation pressure and start collecting permeate in a suitable measuring vial. 7. If a given up-concentration degree is desired, the correct amount of retentate relative to the measured amount of permeate must continuously be taken out through the Retentate Outlet valve (7) by adjusting the valve carefully during operation. 8. When the feed tank is nearly empty you can choose to refill it: a. Downregulate the feed pressure to 0 bar on the Feed Pressure Regulator (1) b. Close the Retentate Outlet valve (7) and the Feed Inlet valve (4) c. Ensure that tank is not pressurized, Refill the feed tank and close it securely d. Open the Feed Inlet valve (4) e. Regulate the feed pressure to the operating pressure on the Feed Pressure Regulator (1) f. Start adjusting the retentate flow on the Retentate Outlet valve (7) as before the refilling 9. When the feed tank is empty, air will enter the retentate chamber and the filtration process must be stopped. It is possible to run the filtration process until air reaches the Permeate Outlet (approx. 75ml of retentate left in the chamber). a. Downregulate the feed pressure on the Feed Pressure Regulator (1) to approx. 0,1 bar b. Stop the vibration motor c. Open the Retentate Outlet valve (7) completely to drain out the remaining retentate at low feed pressure 10. Clean the system with the appropriate CIP protocol for your membrane and application and finish the CIP by filling the system with an appropriate storing solution for your membrane and application. 11. Close all valves to the retentate chamber (Airvent (6), Permeate Outlet valve (5), Retentate Outlet valve (7) and Feed Inlet valve (4)). The Vibro -LE is now ready for storage. 15

16 d. Continues Operation with the SANI Membranes Standard Continuous Feed System 1. Start with a fully assembled and drained Vibro -LE system as shown above with all valves and regulators closed. 2. Fill the feed reservoir (not shown) with your feed solution. 3. Open the Airvent (6), the Feed Inlet valve (4) and the Permeate Outlet valve (5). 4. Fill the retentate chamber by slowly starting your Feed Pump (1). Follow the filling of the retentate chamber visually and close the Airvent (6) when the retentate chamber is full. 5. Start the vibration motor. 6. Adjust the feed pressure with your Feed Pump (1) to the desired operation pressure and start collecting permeate in a suitable measuring vial. 7. If a given up-concentration degree is desired the correct amount of retentate relative to the measured amount of permeate must continuously be taken out through the Retentate Outlet valve (7) by adjusting the valve carefully during operation. 8. When the feed reservoir is empty, the feed pump will take in air and the pressure will drop. Stop the pump and the vibration motor. Empty out the retentate by closing the Feed Inlet valve (4), open the Airvent (6) and open the Retentate Outlet valve (7). 9. Empty the remaining feed out the Feed Chamber (2) and the connected tubing. 10. Clean the system with the appropriate CIP protocol for your membrane and application and finish the CIP by filling the system with an appropriate storing solution for your membrane and application. 11. Close all valves to the retentate chamber (Airvent (6), Permeate Outlet valve (5), Retentate Outlet valve (7) and Feed Inlet valve (4)). The Vibro -LE is now ready for storage. 16

17 e. CIP Operation The following procedure is a general guideline for the cleaning/sanitation of Vibro-LE for most normal applications with a Standard Batch Feed System. Depending on individual process streams, equipment, and process time, some variations in cleaning procedures may be required for optimal cleaning results. Please consult a qualified chemical supplier for application specific cleaning regimes. Water flushes, buffer flushes or CIP cleaning must be performed after each run with media in the Vibro -LE. The appropriate cleaning method must be found for each membrane and membrane application by the user. A typical CIP routine for operation with organic material could consist of: 1. A 7L hot water flush at 0,5 bar with the retentate valve slightly open 2. A 30min 55 C caustic wash at ph 11 and 0,5 bar with an appropriate CIP chemical and the retentate valve slightly open 3. A 7L water flush at 0,5 bar with the retentate valve slightly open 4. A 15min 55 C acid wash at ph 2 and 0,5 bar with an appropriate CIP chemical and the retentate valve slightly open 5. 2 times 7L water flush at 0,5 bar with the retentate valve slightly open 6. Filling of the retentate chamber with an appropriate storage solution (e.g. 20% Ethanol or 1% Sodium metabisulfite) 7. Closing of all valves to the retentate chamber (Airvent (6), Permeate Outlet valve (5), Retentate Outlet valve (7) and Feed Inlet valve (4)) 8. The Vibro -LE is now ready for storage f. Homogenization of viscous/high concentration media in the retentate chamber At high viscosity / high concentrated media mix/homogenization of the retentate in the retentate chamber can be necessary. A Mix Pump (9) can be fitted between the Airvent (4) and the 2 nd Retentate Outlet valve to mix/homogenize the retentate in the chamber during operation. 17

18 5. Assembly a. Assembly of batch production system with the SANI Membranes Standard Batch Feed System 1. Close the Feed Pressure Regulator (1) completely. 2. Connect all pressurized air connections with flexible tubing: a) Connect the external pressurized air (minimum 4 bar) to the Feed Regulator (1) on the Feed Chamber b) Connect the Feed Chamber (2) with the Feed Pressure Regulator (1) on the Feed Chamber c) Connect Air Cushion Inlet 1 with the Feed Pressure Regulator (1) on the Feed Chamber d) Connect Air Cushion Inlet 1 with Air Cushion Inlet 2 3. Connect all fluid connections with flexible tubing: a) Connect the Feed Chamber (2) to the Feed Inlet (4), include an on/off valve with in towards the Feed Inlet (4) b) Connect an on/off valve to the Airvent (6) with in towards the Airvent (6) c) Mount a plug in the Retentate Outlet under the Feed Inlet (4) d) Connect the Retentate Outlet (7) with a hose to your retentate collection vial, include a regulation valve or an on/off valve with in towards the Retentate Outlet (7) e) Connect the Permeate Outlet (5) with a hose to your permeate collection vial include an on/off valve with in towards the Permeate Outlet (5) (the valve should only be in off position during storage) 18

19 b. Assembly of continuous production system with the SANI Membranes Continuous Feed System 1. Close the Feed Pressure Regulator (1) completely. 2. Connect all air connections with flexible tubing: a) Connect the Feed Hydrophore (2) with the Air Cushion Inlet 1 b) Connect Air Cushion Inlet 1 with Air Cushion Inlet 2 3. Connect all fluid connections with flexible tubing: a) Connect the Feed Pump (1) with the Feed Hydrophore (2) b) Connect the Feed Hydrophore (2) to the Feed Inlet (4), include an on/off valve with in towards the Feed Inlet (4) c) Connect an on/off valve to the Airvent (6) with in towards the Airvent (6) d) Mount a plug in the Retentate Outlet under the Feed Inlet (4) e) Connect the Retentate Outlet (7) with a hose to your retentate collection vial include a regulation valve or an on/off valve with in towards the Retentate Outlet (7) f) Connect the Permeate Outlet (5) with to your permeate collection vial, include an on/off valve with in towards the Permeate Outlet (5) (the valve should only be in off position during storage) c. Assembly and removal of the Vibration Motor 1. Assembly of the Vibration Motor a) Place and align the Vibration Motor on Chamber side 2 b) Put the 4 bolts in and tighten them c) Tighten the unbrako bolt between the 2 ball bearings 2. Removal of the Vibration Motor a) Loosen the unbrako bolt between the 2 ball bearings b) Remove the 4 bolts connecting the motor to Chamber Side 2 c) Remove the Vibration Motor 19

20 6. Membrane exchange a. Disassembly of the Membrane Assembly Attention: The membrane surface is extremely fragile. Do not touch the membrane surface at any time. 1. Start with a drained system with all tubing s disconnected. 2. Carefully release the Membrane Assembly from the base plate. Preferably with the leaf springs left in the base plate. 3. Empty out any remaining permeate and retentate from the Membrane Assembly. 4. Place the Membrane Assembly with the vibration motor between your thighs sitting down and start the disassembly. 5. Remove the 8 M8 unbrako bolts from Chamber Side Remove Chamber Side 1 from the Membrane Assembly. 7. Remove the rubber gasket between Chamber Side 1 and the Membrane Chamber. 8. Slide the Membrane Chamber out of Chamber Side Remove the rubber gasket between Chamber Side 2 and the Membrane Chamber. 20

21 10. Take of the two M10 nuts from the Permeate Outlets. 11. Press half of the Permeate Outlets out of the Membrane Chamber by pressing the bolt ends with your finger. 12. Remove the Permeate Outlet ends from the Membrane Chamber with a M8 bolt and a rubber hammer (gentle knocks in an exactly 90 angle from the chamber). 13. Remove any remaining gaskets from the permeate outlet holes in the Membrane Chamber. 14. Slide the Free Flow Plate laboratory element (HPL) out of the Membrane Chamber without touching the membrane with your fingers or the Membrane Chamber. 15. Store the membrane element in an appropriate storing solution without the membrane touching the vial. 16. Clean the parts with 50% EtOH before storing or re-assembly. 21

22 b. Assembly of the Membrane Assembly 1. Clean the parts with 50% EtOH if necessary and check that all gaskets and O-rings are intact. 2. Press the Permeate Outlet ends (with gasket and O-rings) into the holes in the Membrane Chamber after lubricating the O-rings with water. The first O- ring should be covered by the chamber (make sure that the orientation of the chamber is correct for where you want your bottom Permeate Outlet). 3. Place the Membrane Chamber upright on a table with the holes in the bottom and slide the HPL element into the Membrane Chamber from the top, without touching the membrane with your fingers or the Membrane Chamber. 4. Press in the other half of the Permeate Outlets (with gasket and O-rings) after lubricating the O- rings with water. The first O-ring should be covered by the Membrane Chamber (make sure that the orientation of the Membrane Chamber is correct for where you want your bottom Permeate Outlet). 5. Put on the M10 nuts and tighten them carefully until the second O-rings are covered completely by the Membrane Chamber. 6. Check that the HPL is mounted straight. If the HPL is crocked, you should align it by knocking on the permeate exits with a rubber hammer (gentle knocks in an exactly 90 angle from the chamber). 7. Check that all the gaskets are visible within the membrane chamber. If not, then tighten the nuts and realign the HPL with a rubber hammer until the gaskets are all visible and the HPL is aligned in the middle of the Membrane Chamber. 22

23 8. Place Membrane Side 2 with the motor between your thighs sitting down and start the assembly of the Membrane Assembly. 9. Put a rubber gasket in Chamber Side 2 and carefully slide in the Membrane Chamber in the correct orientation. 10. Press the Membrane Chamber into Chamber Side 2 while making sure that the rubber gasket is in place. 11. Place a rubber gasket on top of the Membrane Chamber and carefully press on Chamber Side 1 in the correct orientation, while making sure that the rubber gasket is in place. 12. Put in the 8 M8 unbrako bolts and cross tighten them very carefully (1 st corner,3 rd corner, 2 nd corner, 4 th corner, etc.) until they are all finger tight (It is very hard to tighten with only your little finger 5 cm out on a standard unbrako wrench). 13. Carefully place the Membrane Assembly onto the leaf springs on the base plate. Be careful to center the Membrane Assembly correctly on the leaf springs and press the leaf springs all the way into the slits in the Chamber Sides. 23

24 7. Technical Data Vibro -LE Data Weight Dimensions (L x W x H) Membrane Internal Retentate volume Internal Permeate volume Operating Pressure Temperature Range Vibration Motor Power Consumption Noise Level 10 kg 515 mm x 160 mm x 332 mm 0,35 m 2 HPL element 500 ml, Fully drainable 50 ml, Fully drainable 0-4 bar 5-85 C Electric 240V, 40W excl. feed system dba Vibro -LE Accessories and Spare Parts Standard Batch Feed System 9L Stainless Steel tank with feed pressure regulator and all necessary fittings and tubing s Standard Continuous Feed System Feed pump and Feed Chamber (hydrophore) with all necessary fittings and tubing s Homogenization Pump System Homogenization Pump with all necessary fittings and tubing s Rubber Gasket Set 2 Rubber gaskets for the Air Cushions Ballon Rubber Gasket Set for operation under 1 bar 2 Balloon rubber gaskets for the Air Cushions and 2 plugs for the Air Cushion Inlets Permeate Outlet Set including O-rings and Gaskets 2 Permeate Outlets with gaskets and O-rings (one plugged and one with 8 mm outlet) O-ring / Gasket Set for the permeate outlets 8 gaskets 16 big O-rings and 4 small O-rings for the permeate outlets Leaf Spring Set 2 polymer leaf springs and 2 steel leaf springs Membrane Chamber 1 PVC Membrane Chamber Free Flow Plate Laboratory Element (HPL) Data Generic Design Free Flow Plate. Fused Polypropylenes Membrane Type Most organic membranes (MF, UF, and other filter types) Membrane Area 0,35 m 2 Dimensions (L x W x H) 242 mm x 30 mm x 202 mm Viscosity Range, Apparent cp (e.g. Cream Cheese+) Temperature Range 5-85 C ph Range 1-14 Free Chlorine Membrane dependent Free Flow Plate Laboratory Element (HPL) Standard Membranes Membrane type Cut-off Membrane Material UF 5 kda PES UF 5 kda PESH UF 30 kda PESH UF 100 kda PVDF UF 300 kda PES UF 400 kda PAN MF 800 kda / 0,08 µm PVDF MF 0,2 µm PVDF MF/Filter 1 µm PET (Woven) MF/Filter 5 µm PET (Woven) MF/Filter 10 µm PET (Woven) The HPL can be equipped with your membrane of choice. SANI Membranes have a line of standard MF and UF membranes from Synder, Microdyn-Nadir and others on stock. Most commercial available membranes can however also be used with the HPL. Please, do not hesitate to contact us with your membrane wishes. 24

25 8. Conformity The Vibro-LE system is CE marked to demonstrate compliance with relevant regulations including the European Machine, Electrical and Pressure Directives. 25

Instruction Manual. Alfa Laval SB Pressure Exhaust Valve ESE02965-EN Original manual

Instruction Manual. Alfa Laval SB Pressure Exhaust Valve ESE02965-EN Original manual Instruction Manual Alfa Laval SB Pressure Exhaust Valve ESE02965-EN1 2015-10 Original manual Table of contents The information herein is correct at the time of issue but may be subject to change without

More information

HYDROGEN PEROXIDE Railcar Unloading by Self-Priming Pump Technical Data Sheet

HYDROGEN PEROXIDE Railcar Unloading by Self-Priming Pump Technical Data Sheet HYDROGEN PEROXIDE RAILCAR UNLOADING BY SELF-PRIMING PUMP INTRODUCTION All equipment used for storage and handling of hydrogen peroxide must be dedicated exclusively to hydrogen peroxide service and must

More information

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER SUPPLIMENT TO eom IMPORTANT READ THIS MANUAL BEFORE PRODUCT INSTALLATION, OPERATION, INSPECTION & MAINTENANCE Tougher and more rigid guidelines are being established

More information

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP This operating instructions contains safety information that if ignored can endanger life or result in serious injury. They are indicated by this icon. Use of this pump with radioactive chemicals is forbidden!

More information

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies Type 2000 INOX 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies Quickstart English Deutsch Français Contents 1 QUICKSTART... 2 2 CONTACT ADDRESS... 2 3 INTENDED USE...

More information

Type C-CUT. Quickstart. English Deutsch Français

Type C-CUT. Quickstart. English Deutsch Français Capillary modules for micro and ultrafiltration Kapillarmodule für die Mikro- und Ultrafiltration Modules capillaires pour micro- et ultrafiltration Quickstart English Deutsch Français We reserve the right

More information

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL 00, 0, 000 00, 000, 00 A. TECHNICAL INFORMATION Model 00 Inlet/Outlet " Air Inlet /" 0 / 000 /" /" 00 /" /" 000 /" /" 00 /" /" Flow Rate GPM/ 0LPM GPM/ 0LPM GPM/ LPM GPM/ LPM GPM/ 0LPM GPM/ 0LPM Maximum

More information

Instruction Manual Updated 5/26/2009 Ver. 2.0

Instruction Manual Updated 5/26/2009 Ver. 2.0 Bench-Mount Filter Press With Air Cylinder Part No. 140-35 Instruction Manual Updated 5/26/2009 Ver. 2.0 OFI Testing Equipment, Inc. 11302 Steeplecrest Dr. Houston, Texas 77065 U.S.A. Tele: 832.320.7300

More information

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN Original manual

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN Original manual Instruction Manual Alfa Laval SB Membrane Sample Valve ESE02963-EN2 2016-02 Original manual Table of contents The information herein is correct at the time of issue but may be subject to change without

More information

20 Ton SD Shop Press Operating Instructions

20 Ton SD Shop Press Operating Instructions 20 Ton SD Shop Press Operating Instructions MODEL NO. 850SD Hazard Symbols Used in the Manuals This manual includes the hazard symbols defined below when the operations or maintenance job involves a potential

More information

30T A/Manual Hydraulic Shop Press

30T A/Manual Hydraulic Shop Press 30T A/Manual Hydraulic Shop Press Operation Manual 1 1. Important Information 1.1 Safety Information 1.1.1 Hazard Symbols Used in the Manuals This manual includes the hazard symbols defined below when

More information

Siphon vessel / Priming aid

Siphon vessel / Priming aid Manufacturer: sera GmbH sera-straße 1 34376 Immenhausen Germany Tel.: +49 5673 999-00 Fax: +49 5673 999-01 info@sera-web.com Keep the operating manual for future use! Record the exact type and serial number

More information

Tentec. Instruction Document. Mini Air Driven Pump Unit Model: HTT.627X Series. Part Identifier

Tentec. Instruction Document. Mini Air Driven Pump Unit Model: HTT.627X Series. Part Identifier Tentec Page 1 w w w. t e n t e c. n e t Instruction Document Mini Air Driven Pump Unit Model: HTT.627X Series HTT.6271 Maximum Working Pressure = 1500bar (21750 psi) HTT.6272 Maximum Working Pressure =

More information

User Manual. Quantos Automated Dosing Liquid Module

User Manual. Quantos Automated Dosing Liquid Module User Manual Liquid Module 1 Safety Information 1.1 Definition of warnings and symbols Signal Words WARNING for a hazardous situation with medium risk, possibly resulting in severe injuries or death if

More information

Eaton Filtration, LLC

Eaton Filtration, LLC Eaton Filtration, LLC 900 Fairmount Avenue, Elizabeth, NJ 07207 Phone: 908-787-1000 Fax: 908-351-7893 E-Mail: filtration@eaton.com Web: www.filtration.eaton.com Installation, Operation & Service Manual

More information

Installation Instructions

Installation Instructions Installation Instructions BW Seals Uniseal Series Cartridge metal bellows single and dual seals Experience In Motion Description The Uniseal metal bellows seal series consists of: Uniseal I - Single seals

More information

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator. PRS(TC)4,8 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to

More information

Portable Oil Lube Air Compressors

Portable Oil Lube Air Compressors Portable Oil Lube Air Compressors 8003631 8003632 0410149 8018968 8018940 Owner s Manual Read and understand operating instructions before use Safety definitions The information listed below should be

More information

Type T-CUT PP. Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type T-CUT PP. Operating Instructions. Bedienungsanleitung Manuel d utilisation Tubular/pipe modules for microfiltration Tubular-/Rohrmodule für die Mikrofiltration Modules tubulaires pour microfiltration Operating Instructions Bedienungsanleitung Manuel d utilisation We reserve the

More information

OPERATING MANUAL LO-CROSS-FLOW CF M

OPERATING MANUAL LO-CROSS-FLOW CF M VA FILTRATION USA 110 Dodd Court American Canyon, CA 94503 Tel : (707) 552 2616 Fax :(707) 552 3871 Web : www.vafiltration.com OPERATING MANUAL LO-CROSS-FLOW CF8-2-200M January, 2017 TECHNICAL SPECIFICATIONS

More information

OWNER S TECHNICAL MANUAL

OWNER S TECHNICAL MANUAL EL SERIES OWNER S TECHNICAL MANUAL DP7002 1 Air Operated Diaphragm Pump Description The DP7002 1 air operated diaphragm pump is the ideal device for the pumping, transfer and dispensing of chemical liquids,

More information

Armatures for analytical probes

Armatures for analytical probes Armatures for analytical probes For many different types of installations and applications Large range of probe holders General purpose, water treatment, food & beverage, pharmaceutical applications Type

More information

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator. RS(H)10,15 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to

More information

Hydro-Pneumatic Cylinder HPL-B / HPL-C

Hydro-Pneumatic Cylinder HPL-B / HPL-C Ihr flexibler Problemlöser in der Fluidtechnik Hydro-Pneumatic Cylinder HPL-B / HPL-C DRUMAG GmbH Fluid Technology Glarnerstraße 2 D-79713 Bad Säckingen Telefone: +49 (0)7761 / 5505-0 Fax: +49 (0)7761

More information

OPERATING AND MAINTENANCE MANUAL GOLD LINE EXTRACTION CLEANERS M14-M26

OPERATING AND MAINTENANCE MANUAL GOLD LINE EXTRACTION CLEANERS M14-M26 OPERATING AND MAINTENANCE MANUAL GOLD LINE EXTRACTION CLEANERS M14-M26 Made For: Spitwater Australia Pty Ltd 953 Metry St North Albury, NSW, Australia WARNING: FAILURE TO FOLLOW OPERATING, SAFETY AND MAINTENANCE

More information

Type T-CUT. Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type T-CUT. Operating Instructions. Bedienungsanleitung Manuel d utilisation Tubular/pipe modules for micro and ultrafiltration Tubular-/Rohrmodule für die Mikro- und Ultrafiltration Modules tubulaires pour micro- et ultrafiltration Operating Instructions Bedienungsanleitung Manuel

More information

Eaton Filtration, LLC

Eaton Filtration, LLC Eaton Filtration, LLC 900 Fairmount Avenue, Elizabeth, NJ 07207 Phone: 908-787-1000 Fax: 908-351-7893 E-Mail: filtration@eaton.com Web: www.filtration.eaton.com Installation, Operation & Service Manual

More information

USER MANUAL. MACMAG magnetic separator MHK MHF

USER MANUAL. MACMAG magnetic separator MHK MHF USER MANUAL MACMAG magnetic separator MHK MHF Important Read the safety precautions before use. Thank you for your purchase. This user manual contains important information on avoiding damage and personal

More information

1020 Industrial Drive, Orlinda, TN fax

1020 Industrial Drive, Orlinda, TN fax Operation Manual Ultrafiltration for High Purity Distribution K-A-HPTUF Series 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax TABLE OF CONTENTS Section 1 GENERAL 1.1 Warnings and Cautions... 1 1.2

More information

Pressure booster combination DPA-CRVZS. Operating instructions a [ ]

Pressure booster combination DPA-CRVZS. Operating instructions a [ ] Pressure booster combination en Operating instructions 8074546 2017-07a [8074548] Original instructions -EN Identification of hazards and instructions on how to prevent them: Danger Immediate dangers which

More information

DISASSEMBLY AND ASSEMBLY INSTRUCTIONS FOR LIQUID RING COMPRESSORS

DISASSEMBLY AND ASSEMBLY INSTRUCTIONS FOR LIQUID RING COMPRESSORS DISASSEMBLY AND ASSEMBLY INSTRUCTIONS FOR LIQUID RING COMPRESSORS SA INTRODUCTION These instructions are for the maintenance personnel for maintenance and repair of compressors series SA. Disassembly and

More information

Binks SG-2 Plus TM Rotary 2 QT. PRESSURE CUP

Binks SG-2 Plus TM Rotary 2 QT. PRESSURE CUP Binks SG-2 Plus TM Rotary 2 QT. PRESSURE CUP Model No. 80-651 Rotary Agitator INTRODUCTION Binks SG-2 TM Plus Rotary 2 Qt. Pressure Cup is ideal for component spraying and industrial applications where

More information

DRAFT Standard Operating Procedure Ultrafiltration and Reverse Osmosis

DRAFT Standard Operating Procedure Ultrafiltration and Reverse Osmosis DRAFT Standard Operating Procedure Ultrafiltration and Reverse Osmosis R.Cox 8-2016 Safety Equipment Description R.O Membrane Specifications UF Membrane Specifications Startup Checklist Reverse Osmosis

More information

Hot Compressed Air Lance Operation Manual. LAB Manufacturing 9483 Reading Road Cincinnati, OH (800)

Hot Compressed Air Lance Operation Manual.  LAB Manufacturing 9483 Reading Road Cincinnati, OH (800) Hot Compressed Air Lance Operation Manual www.heatlances.com LAB Manufacturing 9483 Reading Road Cincinnati, OH 45215 (800) 776-5830 PARTS CHECK LIST NOTE: Check all fittings & connections prior to operation.

More information

IMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION

IMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION IMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION This Fitting Guide is designed to assist in the Installation of your Reverse Osmosis System. Some of the parts that are supplied with each system may

More information

Hydrostatic Pressure Testing

Hydrostatic Pressure Testing General An experienced or qualified person will be put in charge of hydro and should meet with the supervisor in charge of the job prior to test. Customer expectations should be clarified prior to beginning

More information

Type C-CUT. Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type C-CUT. Operating Instructions. Bedienungsanleitung Manuel d utilisation Capillary modules for micro and ultrafiltration Kapillarmodule für die Mikro- und Ultrafiltration Modules capillaires pour micro- et ultrafiltration Operating Instructions Bedienungsanleitung Manuel d

More information

Instruction Manual. AlfaLavalSBAntiVacuumValve ESE02960-EN Original manual

Instruction Manual. AlfaLavalSBAntiVacuumValve ESE02960-EN Original manual Instruction Manual AlfaLavalSBAntiVacuumValve ESE02960-EN3 2017-11 Original manual Table of contents The information herein is correct at the time of issue but may be subject to change without prior notice

More information

IMPACT WRENCH MODEL NO: CAT78 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: GC0813

IMPACT WRENCH MODEL NO: CAT78 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: GC0813 IMPACT WRENCH MODEL NO: CAT78 PART NO: 3110790 OPERATING & MAINTENANCE INSTRUCTIONS GC0813 INTRODUCTION Thank you for purchasing this CLARKE Impact Wrench. Before attempting to use this product, please

More information

Manual Actuated Boiler Blowdown Valves

Manual Actuated Boiler Blowdown Valves Manual Actuated Boiler Blowdown Valves Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Operation 5. Maintenance 6. Spare parts p.1 1. Safety

More information

! WARNING. Model PFC-1-G (direct acting) PFC-1-GR (reverse acting) Modulating Pneumatic Liquid Level Controls INSTRUCTION MANUAL MM-110B

! WARNING. Model PFC-1-G (direct acting) PFC-1-GR (reverse acting) Modulating Pneumatic Liquid Level Controls INSTRUCTION MANUAL MM-110B INSTRUCTION MANUAL MM-110B Model PFC-1-G (direct acting) PFC-1-GR (reverse acting) Modulating Pneumatic Liquid Level Controls APPLICATIONS: Use with other pneumatic devices, for liquid level sensing in

More information

BS Series Basket Strainer

BS Series Basket Strainer BS Series Basket Strainer Operating, Installation, & Maintenance Manual Corrosion Resistant Fluid and Air Handling Systems. Dated 04-26-12 PRESSURE DROP SIMTECH strainers are engineered to offer the lowest

More information

75 Ton SD Shop Press Operating Instructions

75 Ton SD Shop Press Operating Instructions 75 Ton SD Shop Press Operating Instructions MODEL NO. 856SD Hazard Symbols Used in the Manuals This manual includes the hazard symbols defined below when the operations or maintenance job involves a potential

More information

Operating and maintenance manual Filter and reducing station Series / 1.0

Operating and maintenance manual Filter and reducing station Series / 1.0 Operating and maintenance manual Filter and reducing station Series 961 04.2017 / 1.0 Original instructions ARCA Regler GmbH. All rights reserved. Cover picture background: Freepik.com ARCA Regler GmbH

More information

Model PSI Compressor with 3-Gallon Air Tank 12VDC

Model PSI Compressor with 3-Gallon Air Tank 12VDC Model 6350 150 PSI Compressor with 3-Gallon Air Tank 12VDC IMPORTANT: It is essential that you and any other operator of this product read and understandd the contents of this manual before installing

More information

Advanced Fluid Handling Cart Owner s Manual

Advanced Fluid Handling Cart Owner s Manual Advanced Fluid Handling Cart IMPORTANT Please read this carefully and thoroughly before installing and operating your Advanced Fluid Handling Cart. Please retain this owner s manual for future reference

More information

AIR STAPLER. MODEL: CSG3KC Part No OPERATING & MAINTENANCE INSTRUCTIONS

AIR STAPLER. MODEL: CSG3KC Part No OPERATING & MAINTENANCE INSTRUCTIONS AIR STAPLER MODEL: CSG3KC Part No. 3110380 0506 OPERATING & MAINTENANCE INSTRUCTIONS SPECIFICATIONS Min. Hose Size (ID)... 6mm (1/4 ) Air Inlet Connector... 10mm Quick Fit Ave. Air Consumption... 0.4 cfm

More information

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0) Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW Tel +44 (0)1254 615100 www.allspeeds.co.uk HP690A Intensifier Panel including the following versions: Model Intensification

More information

200 PSI FAST-FILL AIR SOURCE KIT

200 PSI FAST-FILL AIR SOURCE KIT 200 PSI FAST-FILL AIR SOURCE KIT 55% Duty Compressor on 2.0 Gallon Air Tank PART NO. 20007 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of

More information

OFFICINE OROBICHE S.p.A. 1/9

OFFICINE OROBICHE S.p.A. 1/9 OFFICINE OROBICHE S.p.A. 1/9 INSTRUCTIONS MANUAL FOR LEVEL SWITCHES SERIES 7000 mod. 7250 AND 7400 Electric 1. INSTRUMENT DESCRIPTION Series 7000 level switches have been designed for external lateral

More information

Operation Manual Air Saver Unit ASV5000 Series

Operation Manual Air Saver Unit ASV5000 Series 9IM-V066-b Operation Manual Air Saver Unit ASV5000 Series Thank you for your choice of Kuroda Pneumatics LTDs product on this time. Please read this operation manual carefully and use the product correctly.

More information

ACCU-PULSE Installation and Operation Instructions

ACCU-PULSE Installation and Operation Instructions ACCU-PULSE Installation and Operation Instructions Pump Discharge Installation: Chargeable Models Step 1: Mounting Position Mount ACCU-PULSE as close to the pump discharge as possible to absorb the pulse

More information

User's Manual. MixRite TF 10. Edition 05.08

User's Manual. MixRite TF 10. Edition 05.08 User's Manual MixRite TF 10 Edition 05.08 1 Tefen MixRite TF 10 fertilizer and chemicals Injector Congratulations on your purchase of one of Tefen s high quality products. To get the best results from

More information

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator. LRS(H)4 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to the

More information

Technical Service Bulletin March 2015 TSB142.01

Technical Service Bulletin March 2015 TSB142.01 Technical Service Bulletin March 2015 TSB142.01 Commissioning Procedure for HYDRAcap This Technical Service Bulletin provides information for commissioning of a HYDRAcap membrane system in a water treatment

More information

VERTICAL AIR COMPRESSORS

VERTICAL AIR COMPRESSORS VERTICAL AIR COMPRESSORS MODEL NO: VE11C150, VE15C150, VE18C150 PART NO: 2226005, 2226000, 2226015 OPERATION & MAINTENANCE INSTRUCTIONS LS0615 INTRODUCTION Thank you for purchasing this CLARKE Vertical

More information

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES 450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES PART NO. 45053 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing

More information

Industrial Filter. FGD series

Industrial Filter. FGD series 1/8 P r o d u c t N a m e Industrial Filter Model/ Series/ Product Number FGD series FGD - - - Material Accessory Element length Element Port size Contents 2/8 Safety Instructions 3 Safety Instructions

More information

Design. Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing. Working Principle

Design. Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing. Working Principle SB Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing A family of API liquid ring compressors has been developed and has been in the market for nearly a decade, they are specifically made

More information

Mooney * Noise Controller Installation, Operation, and Maintenance Manual

Mooney * Noise Controller Installation, Operation, and Maintenance Manual GE Oil & Gas Mooney * Noise Controller Installation, Operation, and Maintenance Manual imagination at work Scope This manual provides instructions for installation, operation and maintenance of the Mooney

More information

CS Controlled Dissolved Gas assembly with optional CS Air Aspirator assembly. Installation and Operation information

CS Controlled Dissolved Gas assembly with optional CS Air Aspirator assembly. Installation and Operation information CS-425-01 Controlled Dissolved Gas assembly with optional CS-603-01 Air Aspirator assembly Installation and Operation information Serial # CS-XXX Date of shipment:, 2005 Shipped to: Purchase order #: xxxxxxx

More information

MANUAL SEALLESS STEEL STRAPPING TOOL MODEL A

MANUAL SEALLESS STEEL STRAPPING TOOL MODEL A OPERATION MANUAL / SPARE PARTS LIST MANUAL SEALLESS STEEL STRAPPING TOOL MODEL A337.0001 13.1912.01 13191201.en/MAS/ 10.02 INDEX PAGE 1 SAFETY INSTRUCTIONS 2 2 WARRANTY CONDITIONS AND LIABILITY 4 3 APPROPRIATE

More information

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES EXTREME SERIES PART NO. 45043 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product. SAVE THIS

More information

Installation Operation Maintenance

Installation Operation Maintenance 682 Seal Cooler New generation seal cooler to meet and exceed the seal cooler requirements stated in the 4th Edition of API Standard 682 Installation Operation Maintenance Experience In Motion Description

More information

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator Self-operated Pressure Regulators Type 2357-31 Pressure Build-up Regulator with safety function and integrated excess pressure valve Type 2357-31 with non-return unit at port C Ports A and B with soldering

More information

ACCU-MIX 1200 / / 26270

ACCU-MIX 1200 / / 26270 ACCU-MIX 1200 / 14100 / 26270 Model 102006 (1200) Model 102002 (14100) Model 102003 (26270) Pre filter is required when the water supply is from a in house un filtered well to retain the warranty. Pre

More information

PRESSURE TEST PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model No: PTP100. Part No: GC01/09

PRESSURE TEST PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model No: PTP100. Part No: GC01/09 PRESSURE TEST PUMP Model No: PTP00 Part No: 06020 OPERATING & MAINTENANCE INSTRUCTIONS GC0/09 INTRODUCTION Thank you for purchasing this CLARKE Pressure Testing Pump. Before attempting to use the product,

More information

Freedom8 ShoeBox Compressor Manual

Freedom8 ShoeBox Compressor Manual Freedom8 ShoeBox Compressor Manual Warning!! This product is not a toy! Use or misuse can cause severe injury or death! Use only with adult supervision. This unit is only to be used with tanks, hoses and

More information

Pure Water Power Purification System 4-Stage RODI Operations Manual

Pure Water Power Purification System 4-Stage RODI Operations Manual Pure Water Power Purification System 4-Stage RODI Operations Manual Flush Valve Lever Quick Disconnect for RO Water Testing Water Supply In Drain Hose Pure Water Out to Waterfed Pole New Machine Setup

More information

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out PumpAgents.com - Click here for Pricing/Ordering Model 31670-Series Dual Max 7.5 GPM (28 LPM) AUTOMATIC TWO STAGE WATER SYSTEM WITH ACCUMULATOR TANK AND PUMPGARD STRAINER IDEAL FOR PLEASURE AND COMMERCIAL

More information

BOSS PULISCI PROVA IMPIANTI MEDIA

BOSS PULISCI PROVA IMPIANTI MEDIA BOSS PULISCI PROVA IMPIANTI MEDIA Pump for power flushing operations and removal of impurities, suitable for hydraulic, solar, floor systems and for cooling circuits of medium size. Suitable for buildings,

More information

User Instruction Manual

User Instruction Manual User Instruction Manual 4500 psi Air Compressor Ver 2, 1.18 Contents Parts Included...3 Assembly Instructions...3-5 Operation Instructions...6-7 Oil Change Intervals...8 Air Filter Replacement...9 Setting

More information

Type BBS-03, BBS-05, BBS-06, BBS-25

Type BBS-03, BBS-05, BBS-06, BBS-25 Type BBS-03, BBS-05, BBS-06, BBS-25 Sterile connection elements Sterile Verbindungselemente Raccords union stériles Operating Instructions Bedienungsanleitung Manuel d utilisation 1. THE OPERATING INSTRUCTIONS

More information

Instruction Manual Updated 7/26/2011 Ver. 2.2

Instruction Manual Updated 7/26/2011 Ver. 2.2 4-Unit Model MB HTHP Filter Press #171-50-4: 115-Volt #171-51-4: 230-Volt Instruction Manual Updated 7/26/2011 Ver. 2.2 OFI Testing Equipment, Inc. 11302 Steeplecrest Dr. Houston, Texas 77065 U.S.A. Tele:

More information

ML3M Monnier Miniature Compressed Air Lubricator

ML3M Monnier Miniature Compressed Air Lubricator 5041050/3 IM-P504-04 CH Issue 3 ML3M Monnier Miniature Compressed Air Lubricator Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation and commissioning

More information

Multi-Probe Sampling System User Guide & Manual

Multi-Probe Sampling System User Guide & Manual Multi-Probe Sampling System User Guide & Manual Rev. 06/05/12 Part #22200012 Table of Contents CHAPTER 1: SYSTEM DESCRIPTION... 2 FUNCTION AND THEORY... 3 SYSTEM COMPONENTS... 4 CHAPTER 2: SYSTEM INSTALLATION...

More information

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , & REDQ Regulators Model 411B Barstock Design Powreactor Dome Regulator OPERATION AND MAINTENANCE Contents Scope..............................1 Installation..........................1 General Description....................1

More information

RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL

RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL DESCRIPTION 1. No mar 2. No mar tip 3. Housing grip 4. Trigger 5. Air inlet 6. Air inlet plug 7. Plastic board Important! It is essential that you read the

More information

CRP INSTALLATION, OPERATING AND MAINTENANCE INFORMATION FOR INLINE SAMPLING VALVES

CRP INSTALLATION, OPERATING AND MAINTENANCE INFORMATION FOR INLINE SAMPLING VALVES CRP INSTALLATION, OPERATING AND MAINTENANCE INFORMATION FOR INLINE SAMPLING VALVES Sampling Valves Installation Commissioning and Operating Instructions SD IL 300 & SD IL 400 Inline Sampling Valve This

More information

2 Sentry MCL Installation, Operation & Maintenance

2 Sentry MCL Installation, Operation & Maintenance Gas Liquid & Slurry Solid & Powder Steam & Water Installation, Operation & Maintenance Manual Original Instructions Liquid Sampling Manual Low-Emission Samplers S-GA-IOM-00249-7 11-17 Sentry MCL 966 Blue

More information

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE MODEL NUMBER: M20005 AIR SOURCE KIT 30% Duty Compressor on 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE USER MANUAL IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock

More information

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS Page 1 of 20 Page 2 of 20 TABLE OF CONTENTS Safety Warnings

More information

Hydraulic Punch Drivers

Hydraulic Punch Drivers SERVICE MANUAL 7804SB / 7806SB Quick Draw 7704SB / 7706SB Quick Draw Flex Quick Draw Hydraulic Punch Drivers Serial Codes AHJ and YZ Read and understand all of the instructions and safety information in

More information

Constant Pressure Crude Oil Container Model CPCCP

Constant Pressure Crude Oil Container Model CPCCP Installation, Operations, and Maintenance Manual Constant Pressure Crude Oil Container Model CPCCP The information in this manual has been carefully checked for accuracy and is intended to be used as a

More information

1 DRIVE INDUSTRIAL IMPACT WRENCH

1 DRIVE INDUSTRIAL IMPACT WRENCH 1 DRIVE INDUSTRIAL IMPACT WRENCH 92622 ASSEMBLY AND OPERATING INSTRUCTIONS 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at http://www.harborfreight.com Copyright 2004 by Harbor Freight

More information

200 PSI HIGH-FLOW AIR SOURCE KIT

200 PSI HIGH-FLOW AIR SOURCE KIT 200 PSI HIGH-FLOW AIR SOURCE KIT 50% Duty Compressor on 2.0 Gallon Air Tank PART NO. 20008 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of

More information

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL ATD-8402 90LB PRESSURE BLASTER INSTRUCTION MANUAL SAVE THESE INSTRUCTIONS SAFETY INSTRUCTIONS FOR SANDBLASTER 1. Before opening the tank release the air pressure on the sand tank. To do this, turn off

More information

AIR HAMMERS MODEL NO: CAT138/CAT139 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: / GC064

AIR HAMMERS MODEL NO: CAT138/CAT139 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: / GC064 AIR HAMMERS MODEL NO: CAT138/CAT139 PART NO: 3120152 /3120153 OPERATING & MAINTENANCE INSTRUCTIONS GC064 INTRODUCTION Thank you for purchasing this CLARKE Air Hammer. Before attempting to use this product,

More information

Right-Angle Tube Roller Model

Right-Angle Tube Roller Model SPECIFICATIONS Model no. Free Speed (RPM) Throttle Rotation Max. Torque Ft-Lb Air Pressure psi Air Inlet Hose Air Flow @Free Speed Spindle Weight 909-1700 95 Lever type Reversible 240 90 1/2 NPT 1/2 I.D.

More information

3M Liqui-Cel EXF-10x28 Series Membrane Contactor

3M Liqui-Cel EXF-10x28 Series Membrane Contactor Membrane Contactors 3M Liqui-Cel EXF-10x28 Series Membrane Contactor Assembly and Disassembly Instructions 3M.com/Liqui-Cel TABLE OF CONTENTS I. Safety and Warning 3 II. Assembly Parts 4 III. Part Orientation

More information

For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum WARNING: FOR OUTDOOR USE ONLY

For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum WARNING: FOR OUTDOOR USE ONLY For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum : FOR OUTDOOR USE ONLY Small Tank LP Kit (STLPK) Installation & Operation Instructions Installation We suggest

More information

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment 1. Application Emergency eyewash and eye/face wash equipment are prescribed first aid installations for workplaces

More information

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS 18 GAUGE 1-1/4 INCH BRAD NAILER Model: 7611 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement, or other masonry.

More information

INTENDED USE TECHNICAL SPECIFICATIONS

INTENDED USE TECHNICAL SPECIFICATIONS 1/2IN. HEAVY-DUTY AIR IMPACT WRENCH OWNER S MANUAL WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result

More information

PETERSEN 161-SERIES HIGH PRESSURE LIFTING AIR BAGS OPERATING INSTRUCTIONS WARNING!

PETERSEN 161-SERIES HIGH PRESSURE LIFTING AIR BAGS OPERATING INSTRUCTIONS WARNING! PETERSEN 161-SERIES HIGH PRESSURE LIFTING AIR BAGS OPERATING INSTRUCTIONS WARNING! Read and understand instructions before using Petersen Plugs. Failure to comply may result in property damage, serious

More information

Safety and operating instructions

Safety and operating instructions Safety and operating instructions Oil flow dividers 5, 8 www.cp.com 2 Contents Contents Introduction....................................................................... 5 About the Safety and operating

More information

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0) Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW Tel +44 (0)1254 615100 www.allspeeds.co.uk SOFT LINE CUTTER SL55 PRODUCT CODE No. 980504 INSTRUCTIONS FOR INSTALLATION,

More information

FloWash. Industrial Filter Cart

FloWash. Industrial Filter Cart OPERATION AND MAINTENANCE MANUAL FloWash Industrial Filter Cart Read all instructions before installation or operation of equipment. Failure to comply with these instructions could result in bodily injury

More information

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL 2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL Model: 52024 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement,

More information

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25 Self-operated Pressure Regulators Differential Pressure Regulators (opening) Type 42-20 Type 42-25 Type 42-20 Differential Pressure Regulator Type 42-25 Differential Pressure Regulator Mounting and Operating

More information