SHMS. Downstream Beamline. Large SHMS/HMS Angles (Config-1) Large SHMS / Min HMS Angle (Config-2) Dan Young Ext /26/2015 1

Size: px
Start display at page:

Download "SHMS. Downstream Beamline. Large SHMS/HMS Angles (Config-1) Large SHMS / Min HMS Angle (Config-2) Dan Young Ext /26/2015 1"

Transcription

1 SHMS Dan Young Ext 5255 Downstream Beamline Large SHMS/HMS Angles (Config-1) Large SHMS / Min HMS Angle (Config-2) 1/26/2015 1

2 SHMS Beam Line Large SHMS/HMS Angles (Configuration-1) SHMS minimum angle is 10 HMS minimum angle is 14.5 These angles allow for larger stepped s to clear Magnets and 1.3 Scatter Angle 1/26/2015 2

3 SHMS Beam Line Large SHMS /Min HMS Angles (Configuration-2) SHMS minimum angle is 10 HMS minimum angle is 10.5 This configuration has small diameter to nest inside HMS Q1 at Min HMS Angle. does NOT clear 1.3 Scatter Angle 1/26/2015 3

4 Target Center 0.00 Target Window Flange Section-A Different for Configs 1 & Bellows/ Gate Valve Current distance value. Maybe adjusted in with the new Spool to interface with new Beam Dump Section-B Typical Configs 1 & Section-C Existing s Typical Configurations 1 & Section-C New Spool, Bellows, Viewer New Dog Legged Steel Supports New Steel Support Structure Assy Existing 10, 18 and 24 Aluminum Stands and Supports SHMS Downstream Beamline Layout 1/26/2015 4

5 SHMS Downstream Beamline Scattering Chamber Connection 1/26/2015 5

6 Target Center 0.00 Scattering Chamber Window Flange Transition Configurations 1 & Bellows Gate Valve SHMS Downstream Beamline Scattering Chamber Connection Illustration typical for Large SHMS / HMS Angles and Large SHMS Angle/ Min HMS Angle Configurations 1 and 2 1/26/2015 6

7 Welded Bellows # OD x 1.50 ID CF-Flanges to match Scattering Chamber Window Flange and Gate Valve MDC Gate Valve 2 UHV Manual # Similar to MDC # previously used 2 1/2 inch Gate Valve seals are CF Gaskets in this area CF Flange on SHMS Transition to match Gate Valve SHMS 1 ½ Dia Mount Assembly Transition Different for Configurations 1 & 2 SHMS Downstream Beamline Scattering Chamber Connection Illustration typical for Large SHMS / HMS Angles and Large SHMS Angle/ Min HMS Angle Configurations 1 and 2 1/26/2015 7

8 SHMS Downstream Beamline Section-A and Supports Large SHMS/HMS Angles (Config -1) 1/26/2015 8

9 -Adjustment Assy Bellows and Gate Valve See Slides 5 & 6 Standoff- Dog Leg Aluminum SHMS Transition 1 ½ to 3 ½ SHMS Mount Assembly Standoff-Short Aluminum SHMS 6 SHMS Mount Assembly Standoff-Long Aluminum Horizontal Support Weldment Bolted to Steel Support and Target Adjustment Plate SHMS Downstream Beamline Section-A and Supports 1/26/ Large SHMS/HMS Angles (Config -1) Dog Leg Support-2 Possibly steel due to future side loading from Shielding

10 Target Center 0.00 Scattering Chamber Window Flange Bellows Gate Valve 1-1/2 Aluminum Pipe SHMS Transition 3 1/2 Aluminum Pipe 1.3 Scatter Angle 6 Aluminum Pipe Extending to Section-B SHMS Downstream Beamline Section-A View illustrating diameters and 1.3 Scatter Angle Large SHMS/HMS Angles (Config -1) 1/26/

11 SHMS Downstream Beamline Section-A and Supports Large SHMS/ Min HMS Angle (Config -2) 1/26/

12 -Adjustment Assy Bellows and Gate Valve See Slide 5 & 6 Standoff- Dog Leg Aluminum SHMS Transition 1 ½ to 2 SHMS Mount Assembly Standoff-Short Aluminum SHMS 3 SHMS Mount Assembly Standoff-Long Aluminum Horizontal Support Weldment Bolted to Steel Support and Target Adjustment Plate SHMS Downstream Beamline Section-A and Supports Large SHMS/HMS Min Angle (Config -2) Dog Leg Support-2 Possibly steel due to future side loading from Shielding 1/26/

13 Target Center 0.00 Scattering Chamber Window Flange Bellows Gate Valve 1-1/2 Aluminum Pipe SHMS Transition 2 Aluminum Pipe 1.3 Scatter Angle Outside Beampipe SHMS Downstream Beamline Section-A View illustrating diameters and 1.3 Scatter Angle Large SHMS/HMS Min Angle (Config -2) 3 Aluminum Pipe Extending to Section-B 1/26/

14 SHMS Downstream Beamline Section-B and Supports 1/26/

15 10 (Existing) Support Mount 12 Support Mount seals are to be Metal O-rings Dog Leg Support-2 Possibly steel due to future side loading from Shielding SHMS Downstream Beamline Section-B s and Supports Typical for Configurations 1 and 2 DS Beam Line Support (Existing) /26/

16 10 Aluminum (Existing) 12 Aluminum (New) 1.3 Scatter Angle SHMS Downstream Beamline Section-B View illustrating diameters and 1.3 Scatter Angle 1/26/

17 SHMS Downstream Beamline Section-C and Supports 1/26/

18 Extension Seal Ring Dump Connection Or Exit Window Assy (In Work) seals are to be Metal O-rings SHMS Downstream Beamline Section-C Existing s and Supports DS Support Pole Top Plate Pipe Supports /26/

19 18 Aluminum (Existing) 24 Aluminum s (Existing) 24 Dump Connection Or Exit Window Assy (In Work) Need input clarification and requirements 1.3 Scatter Angle SHMS Downstream Beamline Section-C View illustrating diameters and 1.3 Scatter Angle 1/26/

20 24 Spool Can be fabricated to achieve required location of Exit Window or interface with new Dump Design 24 Bellows Similar in design as existing Bellows Do We Need?? Existing Spool and Window Assembly Design seals are to be Metal O-rings SHMS Downstream Beamline Section-C New Parts to interface with new Beam Dump or Simple Exit Window 1/26/

21 Reference Information And Existing Hardware 1/26/

22 DS Beam Line Support (Existing) DS Support Pole Top Plate Pipe Supports /27/

23 1/26/

24 1/26/

25 1/26/

26 1/26/

27 1/26/

pdf WATER RETICULATION STANDARD VENTILATION LOUVRE BOXES SINGLE AND DOUBLE DUCT SYSTEMS

pdf WATER RETICULATION STANDARD VENTILATION LOUVRE BOXES SINGLE AND DOUBLE DUCT SYSTEMS Drawing Index Name Doc.No Document Description 2001979.061H.pdf 2001979.061 WATER RETICULATION STANDARD SCOUR VALVE CHAMBER WITH CIRCULAR COVER AND FRAME SHEET NO1 OF 2 2001979.062F.pdf 2001979.062 WATER

More information

3/8" Safety Cable Systems

3/8 Safety Cable Systems 3/8" Safety Cable Systems Ladder-Mount 3/8" Cable System (No Slider) Kits include appropriate length of aircraft cable, top and bottom support brackets, 12" tensioning turnbuckle, tension spring, and all

More information

Parts Manual. Scraper Hitches PH:

Parts Manual. Scraper Hitches PH: Parts Manual Scraper Hitches 12-18 1 Table of Contents A123299 Swivel Hitch 3 A1063527 Super Swivel Hitch 4 A125056 Yoke Hitch 5 A125057 Super Capacity Hitch 6 A125223 MDU Hitch 7 A123224 360 Swivel Hitch

More information

VACGEN. Vacuum Components. Product Overview

VACGEN. Vacuum Components. Product Overview VACGEN Product Overview WHY CHOOSE US? In 1964 the Vacuum Generators company was formed in East Grinstead, UK, by Dr Bernard Eastwell and Vic Treasure with a single product - the CR38 all metal right angled

More information

RC102 & RC110 Sample in Vacuum Continuous Flow Cryogenic Workstation Cryostats

RC102 & RC110 Sample in Vacuum Continuous Flow Cryogenic Workstation Cryostats RC102 & RC110 Sample in Vacuum Continuous Flow Cryogenic Workstation Cryostats www.cryoindustries.com INDUSTRIES RC102 & RC110 Sample in Vacuum Continuous Flow Cryogenic Workstation Cryostats Designed

More information

THE ARENA TABLE OF CONTENTS 6 THE ARENA OVERVIEW Dimensions and Tolerances... 2

THE ARENA TABLE OF CONTENTS 6 THE ARENA OVERVIEW Dimensions and Tolerances... 2 Section 6 THE ARENA TABLE OF CONTENTS 6 THE ARENA... 2 6.1 OVERVIEW... 2 6.1.1 Dimensions and Tolerances... 2 6.2 PLAYING FIELD... 4 6.2.1 Boundaries and Markings... 4 6.2.2 The RACK... 5 6.3 GAME PIECES...

More information

Table of Contents FIRST 2005 FIRST Robotics Competition Manual: Section 3 The Arena rev B Page 1 of 8

Table of Contents FIRST 2005 FIRST Robotics Competition Manual: Section 3 The Arena rev B Page 1 of 8 Table of Contents 3 THE ARENA...2 3.1 OVERVIEW...2 3.1.1 Dimensions and Tolerances...3 3.2 PLAYING FIELD...4 3.2.1 Boundaries and Markings...4 3.2.2 Goals...5 3.2.3 Center Goal...5 3.2.4 Tetra Loading

More information

3 THE ARENA 3.1 OVERVIEW Dimensions and Tolerances. [This section includes all modifications through Team Update 10]

3 THE ARENA 3.1 OVERVIEW Dimensions and Tolerances. [This section includes all modifications through Team Update 10] 3 THE ARENA [This section includes all modifications through Team Update 10] 3.1 OVERVIEW Note: The animated pictures in this section of the manual are for a general visual understanding of the field only.

More information

5. STRUCTURAL ANALYSIS

5. STRUCTURAL ANALYSIS 5. STRUCTURAL ANALYSIS The skeletal structure of the experiment casing is constructed from UNISTRUT with all experiment equipment mounted by UNISTRUT provided fasteners. All maximum loads for nuts, bolts,

More information

Part No (Low Changeover) Part No (High Changeover) Part No (High Changeover)

Part No (Low Changeover) Part No (High Changeover) Part No (High Changeover) ELX-S TM UNIT 60% 665020 (Low Changeover) 305274 (High Changeover) 305305 (High Changeover) IMPORTANT: This catalog is published as an aid in identifying the detail parts that make up this complete device.

More information

Parts List for Type S Flowmeters

Parts List for Type S Flowmeters P101 Rev. C Type S Flowmeter Parts List: 5/8" 2" Type S Flowmeters Parts List for Type S Flowmeters 5/8" and 3/4" Type S Flowmeters with 100 and 600 Series Register and Internal Gear Train 28 3.0, 3.1

More information

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Installation, Operation and Maintenance Manual for Back Pressure Regulator Installation, Operation and Maintenance Manual for Back Pressure Regulator Model 8860 2009 Groth Corporation IOM-8860 Rev. B 12541 Ref. ID: 95565 Page 2 of 13 Table of Contents I. INTRODUCTION 3 II. DESIGN

More information

Technical Information Cleanfit CUA451

Technical Information Cleanfit CUA451 TI00369C/07/EN/13.13 71238305 Products Solutions Services Technical Information Cleanfit CUA451 Manually operated retractable assembly for water, wastewater and process media Application Drinking water

More information

Design Based Anchoring 2009 FORD F-150

Design Based Anchoring 2009 FORD F-150 Design Based Anchoring OWNERS MANUAL USERS MANUAL 2008 Chief Automotive Technologies. CHIEF'S LIMITED ONE-YEAR WARRANTY & LIABILITY Chief Automotive Technologies warrants for one year from date of installation

More information

Product Catalog and Pricing

Product Catalog and Pricing 2015 Prices effective December 1, 201 www.greenebinstairs.com Product Catalog and Pricing 177 Main Street; PO Box 191 All Galvanized Material East Lynn IL 60932 F.O.B. East Lynn IL 60932 217-375-2; FAX

More information

Hallscrew Replacement Parts List

Hallscrew Replacement Parts List Hallscrew Replacement Parts List HSO2024, 2028, 2031 & 2035 Open drive single screw compressors April 2013 Page 1 Survey Kits 1 N/A Survey Kit N33050009 95812-415 1 1 N/A Survey Kit N33050011 95812-515

More information

AVK SERIES 601, 602, 603 & 605 UNIVERSAL COUPLINGS, ADAPTORS & END CAPS INSTALLATION, OPERATION & MAINTENANCE MANUAL

AVK SERIES 601, 602, 603 & 605 UNIVERSAL COUPLINGS, ADAPTORS & END CAPS INSTALLATION, OPERATION & MAINTENANCE MANUAL Instruction for use Thank you for selecting an AVK product. With correct use, the product is guaranteed to deliver a long and reliable service. This manual has been prepared to assist you with the installation,

More information

CRYO INDUSTRIES. Liquid Helium Research Dewars

CRYO INDUSTRIES. Liquid Helium Research Dewars Liquid Helium Research Dewars Liquid Helium Research Dewars Cryo Industries Liquid Helium Research Dewars are finely designed and manufactured using the highest quality materials. A Liquid Helium reservoir

More information

Hydrostatic Pressure Testing

Hydrostatic Pressure Testing General An experienced or qualified person will be put in charge of hydro and should meet with the supervisor in charge of the job prior to test. Customer expectations should be clarified prior to beginning

More information

Rosemount 1195 Integral Orifice Primary Element

Rosemount 1195 Integral Orifice Primary Element Quick Installation Guide November 2011 Rosemount 1195 Rosemount 1195 Integral Orifice Primary Element Start Step 1: Primary Element Location Step 2: Primary Element Orientation Step 3: Primary Element

More information

OMS Comfort Harness II

OMS Comfort Harness II Assembly of the Shoulder Pads OMS Comfort Harness II Take the larger of the two pieces of webbing (with grommet) and start at the top of the Back Plate: A) Thread the webbing thru the back slanted slots

More information

Dean Pump Self-Priming Chemical Process Pumps

Dean Pump Self-Priming Chemical Process Pumps Bulletin C 1.2.34.7 Dean Pump Self-Priming Chemical Process Pumps php Series HEAD CAPACITY RANGE CHARTS php Self Primer - 2 Pole 3500 RPM 500 CAPACITY M 3 /HR 2900 RPM 50 HERTZ 25 50 75 125 150 400 TOTAL

More information

L21S/SR/ST Glass Level Gauges

L21S/SR/ST Glass Level Gauges L21S/SR/ST Glass Level Gauges Doc. no.: 150, en_cat_l21s/sr/st, 12/2014 Type of code Example: L21ST/1450/AANSI 3/4 150Lb RF/Large chamber Code 1 Basic type L21 2 Type of gauge S Tubular level gauge SR

More information

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5. Installation Instructions manual MUELLER table of contents PAGE A-20814 Wall Type General Information 2 Technical Data/ Dimensions Installation 4-5 Maintenance 6 Parts 7 Indicator Post! WARNING: 1. Read

More information

3200 Dwight Road Suite #100 Elk Grove, CA Ph: Fax: GNB Corporation

3200 Dwight Road Suite #100 Elk Grove, CA Ph: Fax: GNB Corporation 3200 Dwight Road Suite #100 Elk Grove, CA 95758 Ph: 916-395-3003 Fax: 916-395-3363 www.gnbvalves.com info@gnbvalves.com GNB Corporation Vacuum Excellence Defined A Message from our President Welcome, and

More information

S Surge Arresters

S Surge Arresters Surge Arresters UltraSIL Polymer-Housed VariSTAR Type US, UH, and UX Station-Class Surge Arresters Installation and Maintenance Instructions Service Information S235-88-1 Contents Product Information...........................1

More information

Miniball Coulomb Excitation Target Chamber

Miniball Coulomb Excitation Target Chamber Miniball Coulomb Excitation Target Chamber Nigel Warr May 2011 Contents 1 The Coulomb Excitation Target Chamber 2 2 Mounting 2 3 The Heidelberg collimator 5 4 CD insert 5 5 Selecting targets 6 6 Getting

More information

Vacuum Poppet Valves. Телефон: +7 (499) (многоканальный)

Vacuum Poppet Valves. Телефон: +7 (499) (многоканальный) Vacuum Poppet Valves Product Introduction Isolation Poppet Valves are usually installed in roughing or for line system.most of application may connect to exhausting system, there is potential risk for

More information

ASME Boiler & Pressure Vessel Code Analysis of the 1497 MHz High-Current Cryomodule Helium Vessel

ASME Boiler & Pressure Vessel Code Analysis of the 1497 MHz High-Current Cryomodule Helium Vessel 1.0 Introduction ASME Boiler & Pressure Vessel Code Analysis of the 1497 MHz High-Current Cryomodule Helium Vessel Katherine Wilson 28 May 2007 To minimize the hazards associated with vacuum and pressure

More information

Foundation Products. Poured In Ground Anchor Bolts E1 - E4. Structural Foundations E5 - E12. Copyright 2016 s Industry Inc. SIE-RA-CMP EN

Foundation Products. Poured In Ground Anchor Bolts E1 - E4. Structural Foundations E5 - E12. Copyright 2016 s Industry Inc. SIE-RA-CMP EN Foundation Products Poured In Ground Anchor Bolts E1 - E4 Structural Foundations E5 - E12 EA EB Poured in Ground Anchor Bolts Layout SIEMENS Anchor Bolts 131702-4X shown for reference purposes only! Actual

More information

GAS SUPPLY DESIGN GUIDE

GAS SUPPLY DESIGN GUIDE GAS SUPPLY DESIGN GUIDE Natural Gas, Propane Gas, or Dual Fuel Fired Modulating, Condensing Boilers BENCHMARK Series Gas-Fired Boilers For models: BMK750 to BMK6000 Last Update: 06/20/2014 PR1 06/20/14

More information

Materials : Forged carbon steel A105N

Materials : Forged carbon steel A105N Certificate 3.1 Size : Ends : Min Temperature : Max Temperature : DN 15 to 50 (NPS 1/2" to 2") Flanges RF CLASS 150 (PN20) - 29 C + 425 C Max Pressure : 20 Bars Specifications : Rising non rotating stem

More information

TBV OPERATION AND MAINTENANCE MANUAL SERIES 2800: FLANGED BALL VALVE. For technical questions, please contact the following:

TBV OPERATION AND MAINTENANCE MANUAL SERIES 2800: FLANGED BALL VALVE. For technical questions, please contact the following: TBV OPERATION AND MAINTENANCE MANUAL SERIES 2800: FLANGED BALL VALVE For technical questions, please contact the following: Engineering Department 1537 Grafton Road Millbury, MA 01527 Phone: (508) 887-9400

More information

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body Size : Ends : Min Temperature : Max Temperature : DN 15 to DN 400 Flanges GN10/16-10 C + 120 C Max Pressure : 16 Bars up to DN 200 ( 10 bars over ) Specifications : Removable stainless steel filter Bolted

More information

PRO-TOOLS 7616 INDUSTRIAL LANE TAMPA, FLORIDA PHONE FAX

PRO-TOOLS 7616 INDUSTRIAL LANE TAMPA, FLORIDA PHONE FAX INSTRUCTION SET INSTRUCTION SET DANGER PLEASE READ NEVER DO THIS!!! NEVER START BEND WITH THE TUBE TOO SHORT. TUBE MUST ALWAYS EXTEND TO END OF ALUMINUM BAR OR PAST. WHEN BENDING NEVER LET ALUMINUM BAR

More information

Model PIV UL/FM Post Indicator Valve. Maintenance and Operation Manual UL/FM Post Indicator Valve Configuration AWWA C515

Model PIV UL/FM Post Indicator Valve. Maintenance and Operation Manual UL/FM Post Indicator Valve Configuration AWWA C515 Model 2010 -PIV UL/FM Post Indicator Valve Maintenance and Operation Manual UL/FM Post Indicator Valve Configuration AWWA C515 2 LAYOUT AND SITING At the design stage, it should be considered where valves

More information

TRAVSMART permanent single-cable horizontal lifeline system

TRAVSMART permanent single-cable horizontal lifeline system The Travsmart single-line system provides a smooth travel. It allows the traveler to move freely over the intermediate anchors, minimizing wear and eliminating user assistance. The user s hands remain

More information

- Written price quotations are valid for 30 days from the date of the quote unless otherwise noted.

- Written price quotations are valid for 30 days from the date of the quote unless otherwise noted. SPECIFICATIONS - All material is solid brass with a #8 mirror finish unless otherwise noted. - All material sold by length is priced in one foot increments. ORDERING PROCEDURE - Use a Purchase Order number.

More information

Side-of-Pole Mount for 1 Module (SPM1) For Module Types A & B

Side-of-Pole Mount for 1 Module (SPM1) For Module Types A & B Side-of-Pole Mount for 1 Module (SPM1) For Module Types A & B ASSEMBLY INSTRUCTIONS step-by-step assembly and installation Version 1, Rev A PCN 080311-2 SP3363-1 Side-of-Pole Mount for 1 Module (SPM1)

More information

DUPLEX TECHNICAL INFORMATION FABRICATED DUPLEX STRAINERS

DUPLEX TECHNICAL INFORMATION FABRICATED DUPLEX STRAINERS DUPLEX STRAINER TECHNICAL INFORMATION - 119 - SCREEN OPENINGS 100 Mesh - 30% O.A. 0.006 Openings 80 Mesh - 36% O.A. 0.008 Openings 60 Mesh - 38% O.A. 0.010 Openings 40 Mesh - 41% O.A. 0.016 Openings 30

More information

Tower Accessories & Hardware

Tower Accessories & Hardware Safety-Climb Cable System for Climbing Ladder These Safety-Climb Cable products clamp to climbing ladder rungs up to 1-1/4" (32 mm) in diameter. The products meet or exceed OSH requirements for climbing

More information

Air Mortar User Manual

Air Mortar User Manual Page 1/5 1 Introduction The Air Mortar is a fast-acting pneumatic system, designed to provide a rapid discharge of inert gas when triggered by 12VDC input signal. The standard system vessel has a volume

More information

5k Slickline Lightweight Pressure Control Equipment 4 ID

5k Slickline Lightweight Pressure Control Equipment 4 ID 5k Slickline Lightweight Pressure Control Equipment 4 ID Table of Contents 5k Slickline Lightweight Pressure Control Equipment 4 ID... 1 Hydraulic Slickline Stuffing Box... 3 Wireline Lubricators... 4

More information

! CAUTION! ! WARNING! General Information

! CAUTION! ! WARNING! General Information Great Plains Mfg., Inc. Installation Instructions Used with: 2SF24, 24-Foot Two-Section Drill General Information Two-Section, Hydraulic Folding Marker 2SF30, 30-Foot Two-Section Drill 2SBM30, 30-Foot

More information

Reproduction. Not for 27" & 29" TWO STAGE INTERMEDIATE SNOWTHROWERS Parts Manual for M1227E M1227EX M1529E

Reproduction. Not for 27 & 29 TWO STAGE INTERMEDIATE SNOWTHROWERS Parts Manual for M1227E M1227EX M1529E Parts Manual for 27" & 29" TWO STAGE INTERMEDIATE SNOWTHROWERS 2011 Model No. Description 1696001 M1227E 1696002 M1227EX 1696003 M1529E Briggs & Stratton Yard Power Products Group 535 Macon Road McDonough,

More information

4400 TwinHybrid Gas Seal

4400 TwinHybrid Gas Seal 4400 TwinHybrid Gas Seal EQUIPMENT PREPARATION MECHANICAL SEAL INSTALLATION INSTRUCTIONS 1 2 200.005" 0,13 mm 125 µ" 3,2 µm R a 3 4 32 µ" 0,8 µm R a 1000 ±.002" 0,05mm CAUTIONS These instructions are general

More information

Size : Ends : Min Temperature : Max Temperature : Materials : Galvanized steel flanges

Size : Ends : Min Temperature : Max Temperature : Materials : Galvanized steel flanges Size : Ends : Min Temperature : Max Temperature : DN 32 to 600 Flanges ISO PN10/16-10 C + 100 C for EPDM and + 80 C for NBR Max Pressure : 16 Bars up to DN 300 Specifications : Absorb vibrations and noises

More information

Air Operated Hydraulic Pumping Systems to 50,000 psi

Air Operated Hydraulic Pumping Systems to 50,000 psi High Pressure Equipment Air Operated Hydraulic Pumping Systems to 50,000 psi PS-10: 10,000 psi PS-20: 20,000 psi PS-30: 30,000 psi PS-40: 40,000 psi PS-50: 50,000 psi PS-90: 90,000 psi High Pressure air

More information

HOW TO NOT MEASURE GAS - ORIFICE. Dee Hummel. Targa Resources

HOW TO NOT MEASURE GAS - ORIFICE. Dee Hummel. Targa Resources HOW TO NOT MEASURE GAS - ORIFICE Dee Hummel Targa Resources Introduction Measuring natural gas is both a science and an art. Guidelines and industry practices explain how to accurately measure natural

More information

ROTATING DISK VALVES INSTALLATION AND MAINTENANCE 1. SCOPE 3 2. INFORMATION ON USAGE 3 3. VALVE TYPES 3 4. OPERATORS 5 5. VALVE CONSTRUCTION 6

ROTATING DISK VALVES INSTALLATION AND MAINTENANCE 1. SCOPE 3 2. INFORMATION ON USAGE 3 3. VALVE TYPES 3 4. OPERATORS 5 5. VALVE CONSTRUCTION 6 Sub Section INDEX Page Number 1. SCOPE 3 2. INFORMATION ON USAGE 3 3. VALVE TYPES 3 4. OPERATORS 5 5. VALVE CONSTRUCTION 6 6. INSTALLATION AND OPERATION 6 7. MAINTENANCE 8 8. REPAIR 9 9. ASSEMBLY 10 10.

More information

Safe-T-Stopper. Gas-Free* Service Tee Renewal and Removal for CenterPoint Energy. *In a controlled gas environment

Safe-T-Stopper. Gas-Free* Service Tee Renewal and Removal for CenterPoint Energy. *In a controlled gas environment Safe-T-Stopper Gas-Free* Service Tee Renewal and Removal for CenterPoint Energy *In a controlled gas environment 1 Presentation Goals What is the Safe-T-Stopper? What are the tool s benefits? What is the

More information

Self-operated Regulators Accessories Differential Pressure and Flow Regulators

Self-operated Regulators Accessories Differential Pressure and Flow Regulators Self-operated Regulators Accessories Differential Pressure and Flow Regulators Compression-type fittings Needle valves Compensation chambers Orifice plates Welding neck flanges Control lines Application

More information

PORTABLE LIGHTNING MAST PROTECTION PLP SERIES INSTRUCTION MANUAL

PORTABLE LIGHTNING MAST PROTECTION PLP SERIES INSTRUCTION MANUAL PORTABLE LIGHTNING MAST PROTECTION PLP SERIES INSTRUCTION MANUAL LBA Technology, Inc. Greenville, NC May 20, 2014 Rev 061515 NOTICE This Instruction Manual is prepared by LBA Technology, Inc. specifically

More information

15000 Series Exhausting Arm - Wall Mount Models: 15076/15106/15146

15000 Series Exhausting Arm - Wall Mount Models: 15076/15106/15146 Operation and Maintenance Manual 15000 Series Exhausting Arm - Wall Mount Models: 15076/15106/15146 MONOXIVENT - SOURCE CAPTURE SYSTEMS - info@ Oct. - 2015 Receiving Assembly Information 15000 Series Exhausting

More information

Fluid Dispensing Systems H O S E R E E L S H O S E S HOSE REELS

Fluid Dispensing Systems H O S E R E E L S H O S E S HOSE REELS Fluid Dispensing Systems H O S E R E E L S H O S E S HOSE REELS HOSE REELS SIGNATURE SERIES H O S E S R E E L S FEATURES & BENEFITS Eight position locking precision die cast latch mechanism, with secure

More information

Rate of Flow Valve Series 120

Rate of Flow Valve Series 120 SPECIFICATIONS Rate of Flow Valve Series DIMENSIONS The OCV Series 120 Rate of Flow control valve is designed to control or limit flow to a predetermined rate, regardless offl uctuations in downstream

More information

QUALITY ALUMINUM BOAT LIFTS, INC. INSTRUCTIONS. Dominator Lake Lift

QUALITY ALUMINUM BOAT LIFTS, INC. INSTRUCTIONS. Dominator Lake Lift INSTRUCTIONS Dominator Lake Lift PHONE:251-986-3882 * FAX:251-986-3136 QABLDOMINATORINST.2014 P a g e 1 Quality Aluminum Boat Lifts, INC. Installation Instructions: Dominator Lake Lift Thank you for your

More information

MLS Series Liquid Level Switches. Installation and Operations Manual Section 15

MLS Series Liquid Level Switches. Installation and Operations Manual Section 15 MLS Series Liquid Level Switches Installation and Operations Manual 00-02-0730 2012-11-11 Section 15 In order to consistently bring you the highest quality full featured products, we reserve the right

More information

IECEx Certificate of Conformity Annexe

IECEx Certificate of Conformity Annexe for Certificate No.: IECEx TSA 09.004X Issue No.: 1 Equipment description pertaining to Issue 0 of this Certificate: A range of electrical power distribution, control, protection and monitoring equipment

More information

MSA Confined Space Entry Equipment

MSA Confined Space Entry Equipment MSA Confined Space Entry Equipment Because every life has a purpose... MSA Confined Space Entry Equipment MSA XTIRPA Manhole Guard System Use for confined space vertical entry and fall protection when

More information

B-Too Drilling and Tapping Machine

B-Too Drilling and Tapping Machine Material Specifications Powered by hand or with Ridgid 690 (TM-29) High strength, modular aluminum and steel components Inserts any 3 /4" to 1" corporation stop under pressure Extracts threaded corporation

More information

Variable Temperature Storage Dewar Mount Inserts

Variable Temperature Storage Dewar Mount Inserts Variable Temperature Storage Dewar Mount Inserts All inserts are available for either Liquid Helium or Liquid Nitrogen Dewars! DStat - External cryostat with insert leg DStatMag - Super Conducting Magnet

More information

Pressure Dump Valve Service Kit for Series 2300 Units

Pressure Dump Valve Service Kit for Series 2300 Units Instruction Sheet Pressure Dump Valve Service Kit for Series 00 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00 applicator tanks when the unit

More information

SINGLE VALVE WITH LOW-FLOW BYPASS

SINGLE VALVE WITH LOW-FLOW BYPASS CONTROL VALVES Pressure Reducing Valve Sizing Guide Sizing pilot operated reducing valves is not a complicated process. It starts with determining requirements and following these guidelines in valve size

More information

EPOXY FITTINGS DIMENSIONS

EPOXY FITTINGS DIMENSIONS Bulletin No. A150 May 1, 2004 EPOXY FITTINGS DIMENSIONS 2"-16" GREEN THREAD fittings may be used with GREEN THREAD and RED THREAD II piping. Refer to Chemical Resistance Guide, Bulletin No. E5615, for

More information

WELDING POSITIONER MODEL NO:

WELDING POSITIONER MODEL NO: WELDING POSITIONER WP-250 13-3/4 Diameter Table 0 to 5.5 RPM Rotation Speed Manual Tilt Adjustment 0 to 90 Tilting Angle Standard w/foot Control Switch Shipping Weight 113 lbs. Designed for rotation of

More information

Quality Plastic Pipe Fittings. Technical Data. Fabricated PVC Fittings IPS Class 100, 125, 160, 200 SCH 40 & SCH 80 Solvent Weld & Gasketed

Quality Plastic Pipe Fittings. Technical Data. Fabricated PVC Fittings IPS Class 100, 125, 160, 200 SCH 40 & SCH 80 Solvent Weld & Gasketed Quality Plastic Pipe Fittings Technical Data Fabricated PVC Fittings IPS Class 100, 125, 160, 200 SCH 40 & SCH 80 Solvent Weld & Gasketed Effective April 1, 2002 PIPE DIMENSIONS IPS-IRON PIPE SIZE Minimum

More information

Design of a Solid Wall Transonic Wind Tunnel

Design of a Solid Wall Transonic Wind Tunnel Design of a Solid Wall Transonic Wind Tunnel David Wall * Auburn University, Auburn, Alabama, 36849 A solid wall transonic wind tunnel was designed with optical access from three sides to allow for flow

More information

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators Technical Instructions Document No. 155-51P5 VG August 1, 01 VGG VGD0 VGD0 Description Only when assembled to Series SKP actuators

More information

GIRARD EQUIPMENT, INC. Specialty Valve Manufacturers for Tank Trailers since 1952

GIRARD EQUIPMENT, INC. Specialty Valve Manufacturers for Tank Trailers since 1952 Pressure Testing Girard DOT407 Pressure Relief Vents GIRARD EQUIPMENT, INC. Specialty Valve Manufacturers for Tank Trailers since 1952 908-862-6300 Toll Free 800-526-4330 FAX 908-862-8178 Website: www.girardequip.com

More information

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators Technical Instructions Document No. 155-51P5 VG August 11, 005 GAS009R1 VGG VGD0 VGD0 Description Only when assembled to SKP

More information

REPAIR PART NUMBER NUMBER DESCRIPTION 0137 ELE 0136 ELE 12 VOLT SOLENOID

REPAIR PART NUMBER NUMBER DESCRIPTION 0137 ELE 0136 ELE 12 VOLT SOLENOID PART REPAIR PART NUMBER NUMBER DESCRIPTION 0137 ELE 0136 ELE 12 VOLT SOLENOID 0203 WHL 0250 WHL WHEEL HUB 0251 WHL AXLE 0252 WHL DUST CAPS 0253 WHL TIRE - 210 SP 0204 WHL 0211 WHL TIRE & WHEEL - SP 0250

More information

Pressure Dump Valve Service Kit for Series 3000 Units

Pressure Dump Valve Service Kit for Series 3000 Units Instruction Sheet Pressure Dump Valve Service Kit for Series 000 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00, 400, 500, and 700 applicator

More information

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3. Installation Instructions manual MUELLER table of contents PAGE A-20806 A-20807 Adjustable General Information 2 Technical Data 3 Dimensions 4 Installation 5-6 Parts 7 Maintenance 8 Vertical Indicator

More information

CHAIN LINK FENCE GATE

CHAIN LINK FENCE GATE WALCOOM Walcoom Corporation CHAIN LINK FENCE GATE Chain link fence gate is a versatile product in many aspects, here, Walcoom provides buyers with sufficient strength and durability chain link fence gate

More information

Vertical Bladder Tanks

Vertical Bladder Tanks DATA SHEET Vertical Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

Halsey Taylor Owners Manual

Halsey Taylor Owners Manual Halsey Taylor Owners Manual Non-Refrigerated Fountains OVL-EBP OVL-SBP OVL-SEBP OVL-ESBP Installer To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE ITRUCTIO BEFORE STARTING

More information

4 IN. BALL LAUNCHER Engine Mounted / PTO Driven

4 IN. BALL LAUNCHER Engine Mounted / PTO Driven 4 IN. BALL LAUNCHER Engine Mounted / PTO Driven OPERATOR S PARTS and MAINTENANCE MANUAL 2006 EDITION BL-MAN-4EN Creation Revision date: 10MAR06 date: by: Ivon LeBlanc by: Table of Contents Table of Contents...

More information

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body Size : Ends : Min Temperature : Max Temperature : DN 40 to DN 300 Flanges R.F. PN10/16-10 C + 80 C Max Pressure : 16 Bars up to DN200 Specifications : Removable stainless steel filter Bolted bonnet with

More information

A new concept in the storage of liquefied chemical and petrochemical gases Zero leakage Zero fugitive emissions

A new concept in the storage of liquefied chemical and petrochemical gases Zero leakage Zero fugitive emissions A new concept in the storage of liquefied chemical and petrochemical gases Zero leakage Zero fugitive emissions Introduction Industries involved in the handling of dangerous fluids have to answer increasing

More information

VALVES & MEASUREMENT

VALVES & MEASUREMENT VALVES & MEASUREMENT TBV OPERATION AND MAINTENANCE MANUAL SERIES 1100: THREE PIECE BALL VALVE For technical questions, please contact the following: Engineering Department 1537 Grafton Road Millbury, MA

More information

I.H.S INSTALLATION INSTRUCTIONS

I.H.S INSTALLATION INSTRUCTIONS I.H.S INSTALLATION INSTRUCTIONS TOOLS REQUIRED The following tools will be required for installation of your I.H.S. system. Item Qty Needed 9/16 Open End Wrench 2 3/4 Open End Wrench 1 1/2 Open End Wrench

More information

Materials : Forged carbon steel A350 LF2

Materials : Forged carbon steel A350 LF2 Size : Ends : Min Temperature : Max Temperature : DN 15 to 50 (NPS 1/2" to 2") Female - Female NPT, Socket Welding - 46 C + 425 C Max Pressure : 250 Bars (Class 1500) Specifications : Rising rotating stem

More information

CVS 4150 and 4160 Pressure Controllers

CVS 4150 and 4160 Pressure Controllers Instruction Manual CVS 4150 and 4160 Pressure Controllers Introduction CVS 4150 and 4160 controllers are designed to provide years of reliable and accurate service. These instructions cover maintenance,

More information

MSA Confined Space Entry Equipment

MSA Confined Space Entry Equipment MSA Confined Space Entry Equipment Because every life has a purpose... MSA Confined Space Entry Equipment MSA XTIRPA Manhole Guard System Use for confined space vertical entry and fall protection when

More information

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3. Installation Instructions manual MUELLER table of contents PAGE A-20808 General Information 2 Technical Data 3 Dimensions 4 A-20809 Non-Adjustable Installation 5-6 Parts 7 Maintenance 8 Vertical Indicator

More information

RECOMMENDATION FOR INTERCHANGEABLE FLANGED DRILLING CHOKE DIMENSIONS

RECOMMENDATION FOR INTERCHANGEABLE FLANGED DRILLING CHOKE DIMENSIONS RECOMMENDATION FOR INTERCHANGEABLE FLANGED DRILLING CHOKE DIMENSIONS TECHNICAL REPORT TR0601 AWHEM publications may be used by anyone desiring to do so. Every effort has been made by the Association to

More information

GREIG FILTERS, INC. OPERATION MANUAL

GREIG FILTERS, INC. OPERATION MANUAL GREIG FILTERS, INC. OPERATION MANUAL MODEL DCFH 3P 15/3 100 S4 DOE/222 DUAL CARTRIDGE FILTER HOUSING TABLE OF CONTENTS I. INTRODUCTION II. CARTRIDGE FILTER HOUSING UNIT A. OPERATION B. INSTALLATION C.

More information

Johnston Invar Coupling Johnston Invar Coupling

Johnston Invar Coupling Johnston Invar Coupling Johnston Invar Coupling Rev.10 (2017.07) AvdS Page 1 of 8 Table of contents I. STRUCTURE OF THE MANUAL / CLARIFICATION... 3 II. SAFETY AND HEALTH CONCERNS... 4 1 GENERAL REMARK... 5 2 ASSEMBLY INSTRUCTIONS...

More information

Advantage Lockers & Bike

Advantage Lockers & Bike Advantage Lockers & Bike Advantage Bike Racks & Lockers Inc. is the #1 supplier of Storage Lockers and Bike Racks to the Lower Mainland s residential construction industry. With 25+ years of experience

More information

3 AND 6 SIDE ARMS, STRAIGHT/TAPERED TOWER SECTIONS

3 AND 6 SIDE ARMS, STRAIGHT/TAPERED TOWER SECTIONS A GENERAL TOWER & SITE ACCESSORIES 3 AND 6 SIDE ARMS, STRAIGHT/TAPERED TOWER SECTIONS 3 6 Tower Leg 2.38 O.D. x 5 Long Mounting Tube Tower Leg 2.38 O.D. x 5 Long Mounting Tube 3 Side Arm 6 Side Arm UNIVERSAL

More information

MUELLER. Mega-Lite Drilling Machine. Reliable Connections. table of contents PAGE. Equipment 2. Operating Instructions 3-4. Parts Information 5

MUELLER. Mega-Lite Drilling Machine. Reliable Connections. table of contents PAGE. Equipment 2. Operating Instructions 3-4. Parts Information 5 operating Instructions manual MUELLER Mega-Lite Drilling Machine table of contents PAGE Equipment 2 Operating Instructions 3-4 Parts Information 5 Travel Charts 6-11! WARNING: 1. Read and follow instructions

More information

E Lightband Compression Tool Operating Procedure

E Lightband Compression Tool Operating Procedure 2002159E Lightband Compression Tool Operating Procedure Organization Name MLB Diameter MLB Assembly Number MLB Assembly Revision MLB Serial Number Instructions: IF LCTS ARE NOT YET INSTALLED ON LIGHTBAND:

More information

THOR 10 HAMMER CAGE INSTRUCTIONS

THOR 10 HAMMER CAGE INSTRUCTIONS 75 " 7m 78 4" m 6" 8.8m 45 ".70m 4.9deg 6 4" 6m 44 4".67m 75 " 7m 9 4" 0m 44".m 497 4".64m The 70, Thor Hammer Cage, consists of four heavy duty aluminum net poles. The unique pole structure reduces the

More information

Halsey Taylor Owners Manual

Halsey Taylor Owners Manual Halsey Taylor Owners Manual Wall Mount Steel Refrigerated Fountains INSTALLER These series fountains are among the easiest to install Fountains on the market today. To assure you install these models easily

More information

GUARDIAN FALL PROTECTION

GUARDIAN FALL PROTECTION 2015 V2 GUARDIAN FALL PROTECTION Product Mini Catalog 2015 For more information, go to www.guardianfall.com or call 800.466.6385 OUR VISION TO ALWAYS BE THE MARKET S FIRST CHOICE FOR FALL PROTECTION AND

More information

SIF Exploded Views 10/3/2016

SIF Exploded Views 10/3/2016 SIF Exploded Views 10/3/2016 Direct Drive Square Inline Fan 9-10 Direct Drive Square Inline Fan - Part Information Item # Description of Parts 9DD # 10DD # 9DD-SS # 10DD-SS # 1 Base SIF910DDBASE 1 SIF910DDBASE

More information

Table for PP. over welding cool-down time 0,10 (PP) time pressure pressure in

Table for PP. over welding cool-down time 0,10 (PP) time pressure pressure in The standard value for heating element is 210 C +/- 10 C. The smaller the pipe wall the higher the. Additional to the given force and to the welding force the moving force of the support must be added!

More information

John Crane Type 609HTC/ECS (High-Temperature Corrosion Resistant) Sealol Metal Bellows Seal Installation Instructions

John Crane Type 609HTC/ECS (High-Temperature Corrosion Resistant) Sealol Metal Bellows Seal Installation Instructions I-609HTC/ECS John Crane Type 609HTC/ECS (High-Temperature Corrosion Resistant) Sealol Metal ellows Seal Installation Instructions Foreword These instructions are provided to familiarize the user with the

More information

Thanks for choosing EJAI SOLAR product

Thanks for choosing EJAI SOLAR product SPLIIT SOLAR WATER HEATER (( YYJ--S01 SERIIES )) IINSTALLATIION MANUAL www.ejaisolar.com ZHEJIANG EJAI SOLAR TECHNOLOGY CO.,LTD. 1 Thanks for choosing EJAI SOLAR product Content 1. Important Information....2

More information