1 55 12 Series REMOTE MOUNTING TEMPERATURE SWITCH AND CONTROL features Single or Dual 15 A Switch Output Panel or Surface Mount Skeleton or Enclosure Type 4X Construction Heat Tracing Models Adjustable Ranges Within -130 to 650 F (-90 to C) U N I T E D E L E C T R I C C O N T R O L S B - 0 2

2 overview The E provides rugged, dependable temperature control for many applications. Available in single or dual output versions, with either an epoxy coated enclosure (type 4X) or skeleton construction, the E55 combines flexibility with compact size. It has been used in diverse applications such as food service appliances, oven control, and heat tracing. features Single or dual 15 A switch output Panel or surface mount Optional external manual reset Heat tracing models Copper or stainless steel bulb & capillary Remote mount heat tracing model (E55-R25HT) Dual switch, skeleton model u n i t e d e l e c t r i c c o n t r o l s B - 0 2

3 5 5 S e r i e s specifications STORAGE TEMPERATURE -65 to 160 F (-54 to 71 C) AMBIENT TEMPERATURE -40 to 160 F (-40 to 71 C); set point typically shifts less than 1% of range for a 50 F LIMITS (28 C) ambient temperature change SET POINT REPEATABILITY SHOCK VIBRATION ± 1% of adjustable range Set point repeats after 15 G, 10 millisecond duration Set point repeats after 2.5 G, Hz ENCLOSURE CLASSIFICATION Type E55 & E55A: Designed to meet enclosure type 4X requirements Types E55S & E55AS: Skeleton, open frame construction, not applicable ENCLOSURE SWITCH OUTPUT ELECTRICAL RATING ELECTRICAL CONNECTION WEIGHT BULB AND CAPILLARY TEMPERATURE FILL TEMPERATURE DEADBAND Die cast aluminum, epoxy powder coated with stainless steel, gasketed adjustment cover (E55 and E55A) One or two SPDT; dual switch may be separated up to 100% of range; switches may be wired normally open or normally closed 15 A 125/250/480 VAC resistive; 22 A 480 VAC for E55-R25HT and E55-L24HT heat trace models. Electrical switches have limited DC capabilities. Consult factory for additional information 1/2 NPT (female) (E55 and E55A) Types E55S, E55AS (skeleton): approximately 12 oz.; Types E55, E55A: approximately 1 lb. Models E20BC - E23BC: 6 feet copper; Models E20BS - E23BS: 6 feet stainless steel Model R25HT-101: 10 feet stainless steel Model L24HT: stainless steel, Local sensor, no capillary, for ambient sensing Non-toxic oil Typically 1% of range under laboratory conditions (70 F circulating bath at rate of 1/2 F per minute change) approvals UNITED STATES AND CANADA E55(A) Models UL Listed, CSA Certified UL 873, file # E10667; C22.2 no. 24, file # LR7814 E55(A)S Models UL Recognized, CSA Certified UL 873, file # E10667; C22.2 no. 24, file # LR7814 EUROPE Low Voltage Directive (LVD) (73/23/EC & 93/68/EEC) UEC compliant to LVD Products rated lower than 50 VAC and 75 VDC are outside of the scope of the LVD B u n i t e d e l e c t r i c c o n t r o l s

4 model chart Model Adjustable Set Point Range Max. Temp. Dial Div. Bulb Size Copper bulb & capillary F C F C F C OD x Length (inches) E20BC -130 to to /8 x 4-3/8 E21BC 0 to to /8 x 6-7/8 E22BC 50 to to /8 x 4-3/8 E23BC 150 to to /8 x 3-5/8 Stainless steel bulb and capillary E20BS -130 to to /8 x 4-3/8 E21BS 0 to to /8 x 6-7/8 E22BS 50 to to /8 x 4-3/8 E23BS 150 to to /8 x 3-5/8 R25HT 25 to to /4 x 7-3/16 L24HT 15 to to /8 x 7 Not available with Type E55AS Not available with Types E55A, E55S, E55AS 4 u n i t e d e l e c t r i c c o n t r o l s B - 0 2

5 5 5 S e r i e s how to order Building a part number Select a Type Refer to the Type section below. Determine type number based on switch output, enclosure, adjustment and reference. Fill in the type portion of your part number with the corresponding number. type E55 E55A E55S E55AS Select a Model Refer to the Model Charts. Determine model based on adjustable range, and capillary material. Fill in the model portion of your part number with the corresponding number. Select an Option Refer to the Options section. Determine option number based on switch output, optional materials or other product enhancements. Fill in the option portion of your part number with the corresponding number. Leave option portion blank if no options are needed. For multiple options: Call. Bulb & capillary; one SPDT output; Epoxy coated enclosure; external adjustment with reference dial, tamper-resistant cover Bulb & capillary; two SPDT outputs; Epoxy coated enclosure; external adjustment with reference dial, tamper-resistant cover Bulb & capillary; one SPDT output; skeleton construction; external adjustment with reference dial Bulb & capillary; two SPDT outputs; skeleton construction; external adjustment with reference dial Switch options* 0500 Close deadband, 5 A 125/250 VAC resistive. NOT AVAILABLE ON MODELS R25HT, L24HT 1530 External manual reset, 15 A 125/250/480 VAC resistive; reset on increasing temperature. NOT AVAILABLE ON TYPES E55S, E55AS, & MODELS R25HT, L24HT A 125/250 VAC resistive. NOT AVAILABLE ON MODELS R25HT, L24HT general M020 Pilot light. available Heat Trace Models R25HT, L24HT ONLY M201 Factory set one switch; specify increasing or decreasing temperature and set point. NOT AVAILABLE ON TYPES E55A, E55AS M202 Factory set two switches; specify increasing or decreasing temperature and set point. NOT AVAILABLE ON TYPES E55, E55S M270 Calibrated dial in Celsius. NOT AVAILABLE ON HEAT TRACE MODELS R25HT, L24HT M444 Paper ID tag. NOT AVAILABLE ON HEAT TRACE MODELS R25HT, L24HT M446 Stainless steel ID tag & wire attachment UNION CONNECTORS** (Not available on models R25HT, L24HT) Option Replacement Number Description Brass W027 SD /2 NPT w/ 3/4 bushing W045 SD /4 NPT W051 SD /2 NPT 304 Stainless Steel W028 SD /2 NPT w/ 3/4 bushing W046 SD /4 NPT W050 SD /2 NPT THERMOWELLS** For all bulb & capillary switches, all 1/2 NPT Internal (Not available on models R25HT, L24HT) Brass W075 SD /2" NPT with 3/4 NPT bushing adapter, 4 BT W191 SD /2 NPT, 4 BT W118 SD /2" NPT with 3/4 NPT bushing adapter, 7 BT W192 SD /2 NPT, 7 BT 316 Stainless Steel W076 SD /4 NPT, 4.5 BT W193 SD /2 NPT, 4.5 BT W119 SD /4" NPT, 7.5 BT W177 SD /2 NPT, 7.5 BT OPTIONAL LENGTHS: Optional capillary length to 50 available in copper or 304 st/st. Armor or Teflon capillary protection available to lengths less than or equal to capillary length. Consult UE for additional information. Consult UE regarding repeatability and ambient effects on capillary lengths over 30. * All switch options have limited DC capabilities. Consult factory for details. ** Dimensional drawings for union connector and thermowells may be found at B u n i t e d e l e c t r i c c o n t r o l s

6 dimensional drawings Types E55 /E55A Type E55 Heat Tracing Models 6 u n i t e d e l e c t r i c c o n t r o l s B - 0 2

7 5 5 S e r i e s Type E55AS Type E55S B u n i t e d e l e c t r i c c o n t r o l s

8 recommended PraCtICeS and WarNINGS Company recommends careful consideration of the following factors when specifying and installing UE pressure and temperature units. Before installing a unit, the Installation and Maintenance instructions provided with unit must be read and understood. To avoid damaging unit, proof pressure and maximum temperature limits stated in literature and on nameplates must never be exceeded, even by surges in the system. Operation of the unit up to maximum pressure or temperature is acceptable on a limited basis (e.g., start-up, testing) but continuous operation must be restricted to the designated adjustable range. Excessive cycling at maximum pressure or temperature limits could reduce sensor life. A back-up unit is necessary for applications where damage to a primary unit could endanger life, limb or property. A high or low limit switch is necessary for applications where a dangerous runaway condition could result. The adjustable range must be selected so that incorrect, inadvertent or malicious setting at any range point cannot result in an unsafe system condition. Install unit where shock, vibration and ambient temperature fluctuations will not damage unit or affect operation. When applicable, orient unit so that moisture does not enter the enclosure via the electrical connection. When appropriate, this entry point should be sealed to prevent moisture entry. Unit must not be altered or modified after shipment. Consult UE if modification is necessary. Monitor operation to observe warning signs of possible damage to unit, such as drift in set point or faulty display. Check unit immediately. Preventative maintenance and periodic testing is necessary for critical applications where damage could endanger property or personnel. Electrical ratings stated in literature and on nameplate must not be exceeded. Overload on a switch can cause damage, even on the first cycle. Wire unit according to local and national electrical codes, using wire size recommended in installation sheet. Do not mount unit in ambient temp. exceeding published limits. LIMIteD WarraNtY Seller warrants that the product hereby purchased is, upon delivery, free from defects in material and workmanship and that any such product which is found to be defective in such workmanship or material will be repaired or replaced by Seller (Ex-works, Factory, Watertown, Massachusetts. INCOTERMS); provided, however, that this warranty applies only to equipment found to be so defective within a period of 24 months from the date of manufacture by the Seller. Seller shall not be obligated under this warranty for alleged defects which examination discloses are due to tampering, misuse, neglect, improper storage, and in any case where products are disassembled by anyone other than authorized Seller s representatives. EXCEPT FOR THE LIMITED WARRANTY OF REPAIR AND REPLACEMENT STATED ABOVE, SELLER DISCLAIMS ALL WARRANTIES WHATSOEVER WITH RESPECT TO THE PRODUCT, INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. LIMItatION Of SeLLer S LIaBILItY Seller s liability to Buyer for any loss or claim, including liability incurred in connection with (i) breach of any warranty whatsoever, expressed or implied, (ii) a breach of contract, (iii) a negligent act or acts (or negligent failure to act) committed by Seller, or (iv) an act for which strict liability will be inputted to seller, is limited to the limited warranty of repair and/or replacement as so stated in our warranty of product. In no event shall the Seller be liable for any special, indirect, consequential or other damages of a like general nature, including, without limitation, loss of profits or production, or loss or expenses of any nature incurred by the buyer or any third party. ue specifications subject to change without notice. u.s. SaLeS OffICeS 31 Old Stage Road Hampton Falls, NH Phone: northeastsales@ueonline.com 28 N. Wise Ave. Freeport, IL Phone: midwestsales@ueonline.com 1022 Vineyard Drive Conyers, GA Phone: southeastsales@ueonline.com 5829 Grazing Court Mason, OH Phone: midatlanticsales@ueonline.com 102 Salazar Court Clayton, CA Phone: westcoastsales@ueonline.com 27 Summit Terrace Sparta, NJ Phone: easternsales@ueonline.com 4306 Whickham Drive Fulshear, TX Phone: southwestsales@ueonline.com 5201 Arbor Court Odessa, TX Phone: westtexassales@ueonline.com CaNaDa EASTERN 68 Mosley Crescent Brampton, Ontario Canada L6Y 5C8 Phone: FAX: UNITED ELECTRIC CONTROLS 180 Dexter Avenue, P.O. Box 9143 Watertown, MA USA Telephone: Fax: INterNatIONaL OffICeS CHINA Room 1011, 10th Flr, Huai Hai Zhonghua Building No. 885, Renmin Road, Luwan District Shanghai , P.R. China Phone: chinasales@ueonline.com EASTERN EUROPE & SCANDINAVIA Komorow Kujawska 5, Poland Phone: easterneuropesales@ueonline.com GERMANY An Der Zentlinde 21 D Erbach, Germany Phone: europeansales@ueonline.com INDIA House no. 7, Kamalkunj Society Nizampura, Baraoda (Gujarat), India Phone: +91 (-265) indiasales@ueonline.com ASIA-PACIFIC, Far East No , 2nd Floor Jalan 4/101C Cheras Business Centre Batu 5, Jalan Cheras Kuala Lumpur, Malaysia Phone: fareastsales@ueonline.com MEXICO Andador Austria 102 Fracc. Petroquimica CP Tampico, Tamaulipas Mexico Phone: latinamericasales@ueonline.com RUSSIA, Moscow Kuusinena str., 19A, Office 310 Moscow, , Russia Phone: +7 (095) russiansales@ueonline.com « , Россия, Самара, ул. М.Тореза, 103 Тел.: +7 (846) Факс: +7 (846) info@energoserver.ru

55 Series Series REMOTE MOUNTING TEMPERATURE SWITCH AND CONTROL. features. Single or Dual 15 A Switch Output. Panel or Surface Mount

55 Series Series REMOTE MOUNTING TEMPERATURE SWITCH AND CONTROL. features. Single or Dual 15 A Switch Output. Panel or Surface Mount 55 12 Series REMOTE MOUNTING TEMPERATURE SWITCH AND CONTROL 55 Series features Single or Dual 15 A Switch Output Panel or Surface Mount External adjustment via reference dial Heat Tracing Models Adjustable

More information

55 Series. 55 Series REMOTE MOUNTING TEMPERATURE SWITCH AND CONTROL FEATURES. Single or Dual 15 A Switch Output. Panel or Surface Mount

55 Series. 55 Series REMOTE MOUNTING TEMPERATURE SWITCH AND CONTROL FEATURES. Single or Dual 15 A Switch Output. Panel or Surface Mount REMOTE MOUNTING TEMPERATURE SWITCH AND CONTROL FEATURES Single or Dual 15 A Switch Output Panel or Surface Mount Skeleton or NEMA 4X Construction Adjustable Ranges Within -130 to 650 F (-90 to 340 C) U

More information

REMOTE MOUNTING TEMPERATURE SWITCH AND CONTROL

REMOTE MOUNTING TEMPERATURE SWITCH AND CONTROL 512 5 S er i es 5 5 Se r i e s REMOTE MOUNTING TEMPERATURE SWITCH AND CONTROL FEATURES Single or Dual 15 A Switch Output Panel or Surface Mount External adjustment via reference dial Heat Tracing Models

More information

J21K Series DIFFERENTIAL PRESSURE SWITCH. features

J21K Series DIFFERENTIAL PRESSURE SWITCH. features DIFFERENTIAL PRESSURE SWITCH features Sealed Metal Bellows Sensors Welded 316 Stainless Steel Sensors Gasketed Die-Cast Aluminum Enclosure with Epoxy Coating Single Switch Output Adjustable Ranges: 30

More information

10 Series PRESSURE SWITCH. features

10 Series PRESSURE SWITCH. features PRESSURE SWITCH 10 Series features Tamper-Resistant Field Adjustment Adjustable Ranges from 4 to 7500 PSI (0,3 to 517,1 Bar) Choice of 7 Electrical Terminations 1-1/4" Diameter Height as Small as 3" U

More information

PRESSURE, VACUUM AND TEMPERATURE

PRESSURE, VACUUM AND TEMPERATURE 5 4 S er i es 5 4 Se r i e s PRESSURE, VACUUM AND TEMPERATURE features Compact Size Wide Selection of Adjustable Ranges: Pressure: 30 Hg Vac to 6000 psi (-1 to 413,7 bar) Temperature: -130 to 650 F (-90

More information

J21K Series DIFFERENTIAL PRESSURE SWITCH. features

J21K Series DIFFERENTIAL PRESSURE SWITCH. features DIFFERENTIAL PRESSURE SWITCH J21K Series features Sealed Metal Bellows Sensors Welded 316 Stainless Steel Sensors Gasketed Die-Cast Aluminum Enclosure with Epoxy Coating Single Switch Output Adjustable

More information

800 Series. 800 Series INDICATING TEMPERATURE CONTROLS AND THERMOMETERS FEATURES

800 Series. 800 Series INDICATING TEMPERATURE CONTROLS AND THERMOMETERS FEATURES INDICATING TEMPERATURE CONTROLS AND THERMOMETERS FEATURES Temperature Indication and Control Single or Dual SPDT Output Stainless Steel Bulb and Capillary ± 1% Repeatability NEMA 1, 4, and Explosion Proof

More information

PRESSURE, VACUUM AND TEMPERATURE

PRESSURE, VACUUM AND TEMPERATURE PRESSURE, VACUUM AND TEMPERATURE 54 Series features Compact Size Wide Selection of Adjustable Ranges: Pressure: 30 Hg Vac to 6000 psi (-1 to 413,7 bar) Temperature: -130 to 650 F (-90 to 343.3 C) Choice

More information

Pressure, Vacuum & differential pressure

Pressure, Vacuum & differential pressure 24 Series Pressure, Vacuum & differential pressure 24 Series features Brass & Polysulfone (FDA compliant) Pressure Connections Compact Size Complies with Enclosure Type 4 with watertight conduit fitting

More information

Pressure, Vacuum, Differential Pressure

Pressure, Vacuum, Differential Pressure Pressure, Vacuum, Differential Pressure AND Temperature SWITCHES features 1, 2 & 3 switch outputs Epoxy-coated enclosure designed to meet enclosure type 4X Wide variety of pressure sensors and materials

More information

EXPLOSION - PROOF PRESSURE TRANSMITTER

EXPLOSION - PROOF PRESSURE TRANSMITTER EXPLOSION - PROOF PRESSURE TRANSMITTER FEATURES Fixed range or field-adjustable Pressure Transmitter 4-20 ma or 1-5 VDC output 0.25% accuracy Compact, 316 Stainless Steel, hermetically sealed enclosure

More information

Pressure, Vacuum, Differential Pressure

Pressure, Vacuum, Differential Pressure 100 Series Pressure, Vacuum, Differential Pressure AND Temperature SWITCHES 100 Series features Single Switch Output Epoxy Coated and Gasketed Cast Aluminum Enclosure Designed to meet Enclosure Type 4X

More information

PRESSURE SWITCH. features

PRESSURE SWITCH. features 10 Series PRESSURE SWITCH 10 Series features Tamper-Resistant Field Adjustment Adjustable Ranges from 4 to 7500 PSI (0,3 to 517,1 Bar) Choice of 7 Electrical Terminations 1-1/4" Diameter Height as Small

More information

W Series. W Series HIGH PURITY PRESSURE SWITCHES FOR CLEAN GAS APPLICATIONS FEATURES

W Series. W Series HIGH PURITY PRESSURE SWITCHES FOR CLEAN GAS APPLICATIONS FEATURES W Series HIGH PURITY PRESSURE SWITCHES FOR CLEAN GAS APPLICATIONS FEATURES Clean, Reliable, Long Life Performance Highly Accurate and Repeatable Design Tamper Proof Setting No Adjustment Needed UNITED

More information

PRESSURE, VACUUM, DIFFERENTIAL PRESSURE, AND TEMPERATURE SWITCHES

PRESSURE, VACUUM, DIFFERENTIAL PRESSURE, AND TEMPERATURE SWITCHES 117 S er i es 117 Se r i e s PRESSURE, VACUUM, DIFFERENTIAL PRESSURE, AND TEMPERATURE SWITCHES features Epoxy Coated Type 4X Enclosure and Stainless Steel Component Parts Hermetically Sealed Snap Switch,

More information

Part I - Installation

Part I - Installation 120 Series Explosion-Proof Temperature and Indicating Temperature Switches and Controls Local Mount Types B121, B122, C120 Remote Mount Types E121, E122, E122P, F120; 820E, 822E U N I T E D E L E C T R

More information

features Fixed range or field-adjustable 4-20 ma, 1-5 or 0-10 VDC output 0.25% accuracy Compact, 316 stainless steel, hermetically sealed enclosure

features Fixed range or field-adjustable 4-20 ma, 1-5 or 0-10 VDC output 0.25% accuracy Compact, 316 stainless steel, hermetically sealed enclosure explosion - proof Pressure TRANSMITTER features Fixed range or field-adjustable 4-20 ma, 1-5 or 0-10 VDC output 0.25% accuracy Compact, 316 stainless steel, hermetically sealed enclosure culus & ATEX certified

More information

Part I - Installation

Part I - Installation 120 Series Explosion-Proof Temperature and Indicating Temperature Switches and Controls Local Mount Types B121, B122, C120 Remote Mount Types E121, E122, F120; 820E, 822E UNITED ELECTRIC CONTROLS Installation

More information

Part I -Installation Tools Needed Screwdriver/Adjustable Wrench to 1-1/2 MOUNTING

Part I -Installation Tools Needed Screwdriver/Adjustable Wrench to 1-1/2 MOUNTING 120 Series Explosion-Proof Pressure and Differential Pressure Switches Types J120, J120K, H121, H121K, H122, H122K, H122P U N I T E D E L E C T R I C C O N T R O L S Installation and Maintenance Instructions

More information

PRESSURE, VACUUM, DIFFERENTIAL PRESSURE, TEMPERATURE

PRESSURE, VACUUM, DIFFERENTIAL PRESSURE, TEMPERATURE PRESSURE, VACUUM, DIFFERENTIAL PRESSURE, TEMPERATURE FEATURES Epoxy Coated Type 4X Enclosure and Stainless Steel Component Parts Hermetically Sealed Snap Switch, SPDT or DPDT Output Terminal Block Wiring

More information

features 4-20 ma, HART 7 communication protocol 0.25% accuracy Compact, 316 stainless steel, hermetically sealed enclosure

features 4-20 ma, HART 7 communication protocol 0.25% accuracy Compact, 316 stainless steel, hermetically sealed enclosure explosion - proof HART Pressure TRANSMITTER features 4-20 ma, HART 7 communication protocol 0.25% accuracy Compact, 316 stainless steel, hermetically sealed enclosure culus & ATEX certified for Class I,

More information

Part I -Installation Tools Needed Screwdriver/Adjustable Wrench to 1-1/2 MOUNTING

Part I -Installation Tools Needed Screwdriver/Adjustable Wrench to 1-1/2 MOUNTING 120 Series Explosion-Proof Pressure and Differential Pressure Switches Types J120, J120K, H121, H121K, H122, H122K UNITED ELECTRIC CONTROLS Installation and Maintenance Instructions Please read all instructional

More information

120 Series Explosion-Proof Pressure and Differential Pressure Switches

120 Series Explosion-Proof Pressure and Differential Pressure Switches 120 Series Explosion-Proof Pressure and Differential Pressure Switches Types J120, J120K, H121, H121K, H122, H122K SIL2 Certified UNITED ELECTRIC CONTROLS Installation and Maintenance Instructions Please

More information

Pressure, Vacuum, Differential Pressure

Pressure, Vacuum, Differential Pressure 10 0 S er i es 10 0 Se r i e s Pressure, Vacuum, Differential Pressure AND Temperature SWITCHES features Single Switch Output Epoxy Coated and Gasketed Cast Aluminum Enclosure Type 4X Tamper-Resistant

More information

RoHS. 100 Series. 100 Series. Pressure, Vacuum, Differential Pressure. features. Certified for use in SIL2 functional safety systems.

RoHS. 100 Series. 100 Series. Pressure, Vacuum, Differential Pressure. features. Certified for use in SIL2 functional safety systems. Pressure, Vacuum, Differential Pressure AND Temperature SWITCHES features Certified for use in SIL2 functional safety systems. SIL3 capable NACE MR0175 compliant models Single Switch Output Epoxy Coated

More information

EXPLOSION-PROOF PRESSURE, VACUUM,

EXPLOSION-PROOF PRESSURE, VACUUM, EXPLOSION-PROOF PRESSURE, VACUUM, differential PRESSURE, TEMPERATURE SWITCHES 120 Series FEATURES Class I, Div. 1 & 2, (Zone 1) Class II, Div. 1 & 2 Class III Worldwide approvals and certifications Choice

More information

EXPLOSION-PROOF PRESSURE, VACUUM, DIFFERENTIAL PRESSURE AND TEMPERATURE SWITCHES

EXPLOSION-PROOF PRESSURE, VACUUM, DIFFERENTIAL PRESSURE AND TEMPERATURE SWITCHES EXPLOSION-PROOF PRESSURE, VACUUM, DIFFERENTIAL PRESSURE AND TEMPERATURE SWITCHES 120 Series FEATURES Class I, Div. 1 & 2, (Zone 1) Class II, Div. 1 & 2 Class III Worldwide approvals and certifications

More information

overview Temperature model (Local, Remote sensing also available) 2 U N I T E D E L E C T R I C C O N T R O L S One Series-B-02

overview Temperature model (Local, Remote sensing also available) 2 U N I T E D E L E C T R I C C O N T R O L S One Series-B-02 overview MODELS 2W2D & 2W3A - PLC & DCS DISCRETE INPUT SWITCHING The One Series 2-Wire derives its operating power from the discrete input to which it is connected. Unlike a transmitter, it will do this

More information

EXPLOSION-PROOF PRESSURE, VACUUM, differential PRESSURE and TEMPERATURE SWITCHES

EXPLOSION-PROOF PRESSURE, VACUUM, differential PRESSURE and TEMPERATURE SWITCHES 12 0 S er i es 12 0 Se r i e s EXPLOSION-PROOF PRESSURE, VACUUM, differential PRESSURE and TEMPERATURE SWITCHES Meet global requirements with worldwide certifications and approvals Increase flexibility

More information

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information Liquid Level EK-L CSM_EK-L_DS_E 3 Liquid Level That Is Unaffected by the Color of the or Liquid Mount to bypass pipes. Fit a wide range of pipe diameters: 8 to mm or to mm Built-in Amplifiers to save space.

More information

Electro-Pneumatic Converter YT-940 SERIES

Electro-Pneumatic Converter YT-940 SERIES Electro-Pneumatic Converter YT-940 SERIES PRODUCT MANUAL VERSION 1.00 Contents 1. Introduction 3 1.1 General information for the users. 3 1.2 Manufacturer Warranty 3 1.3 Explosion Proof Warning. 4 2. Product

More information

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr A DIVISION OF THE FREDERICKS COMPANY 2400 PHILMONT AVE. HUNTINGDONVALLEY, PA 19006 PARTS LIST 1 3 4 2 # QTY ITEM DESCRIPTION

More information

Model DPC3500 Continuous Low Range Dew Point Analyzer. Operations Manual

Model DPC3500 Continuous Low Range Dew Point Analyzer. Operations Manual Model DPC3500 Continuous Low Range Dew Point Analyzer Operations Manual Please read, understand, and follow these instructions before operating this equipment. Super Systems, Inc. is not responsible for

More information

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073 Operating instructions Safety Rope Emergency Stop Switches UK ZB0052 / ZB0053 ZB0072 / ZB0073 7390878 / 02 03 / 2011 Contents 1 Safety instructions...3 2 Installation / set-up...4 2.1 Applications...4

More information

RGC-IR Remote Gas Calibrator for IR400

RGC-IR Remote Gas Calibrator for IR400 Remote Gas Calibrator for IR400 The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically authorized in writing by

More information

SC HYDRAULIC ENGINEERING CORPORATION

SC HYDRAULIC ENGINEERING CORPORATION Designers and Manufacturers of Hydraulic and Pneumatic Equipment SC HYDRAULIC ENGINEERING CORPORATION 1130 Columbia Street - Brea, California 92821 - USA Phone (714) 257-4800 - Fax (714) 257-4810 V FLOW

More information

FLOW CONTROL & AIR PILOT SWITCH VALVES

FLOW CONTROL & AIR PILOT SWITCH VALVES DESIGNER AND MANUFACTURER OF HYDRAULIC AND PNEUMATIC EQUIPMENT SC HYDRAULIC ENGINEERING CORPORATION FLOW CONTROL & AIR PILOT SWITCH VALVES A High Pressure History An innovator and pioneer in the field

More information

Installation and Operation Manual

Installation and Operation Manual Installation and Operation Manual WIKA FLR-SBDF / BLR-SBDF Magnetic Level Transmitter (Please retain for future usage) Contact: Gayesco-WIKA USA, L.P. 229 Beltway Green Boulevard Pasadena, TX 77503 www.wika.com

More information

Installation, Operation and Maintenance Manual. TSV Temperature Shut-off Valve SPD Rev. 6 10/07

Installation, Operation and Maintenance Manual. TSV Temperature Shut-off Valve SPD Rev. 6 10/07 Installation, Operation and Maintenance Manual TSV Temperature Shut-off Valve SPD 13.1.2 Rev. 6 10/07 SENTRY EQUIPMENT CORP PO Box 127 Oconomowoc, WI 53066 USA Phone: 262.567.7256 Fax: 262.567.4523 Email:

More information

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual 8 Executive Drive P.O. Box 2105 Toms River, NJ 08754 (732) 244-0010 (800) 337-3762 fax (732) 244-8140 www.permapure.com info@permapure.com

More information

CSA Sample Draw Aspirator Adapter Operator s Manual

CSA Sample Draw Aspirator Adapter Operator s Manual 30-0951-CSA Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0367 Revision: 0 Released: 4/30/15 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating

More information

3800 SERIES END SUCTION PUMP REPAIR PARTS INDEX. Model Model 3804

3800 SERIES END SUCTION PUMP REPAIR PARTS INDEX. Model Model 3804 Model 3801 Model 3804 3800 SERIES END SUCTION PUMP REPAIR PARTS INDEX NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party who maintains

More information

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel: PERMA PURE INSTRUCTION MANUAL FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model 3300 Version 4.06 Perma Pure LLC Tel: 732-244-0010 P.O. Box 2105, 8 Executive Drive Tel: 800-337-3762 (toll free US)

More information

SPS-5. Rate Computing Scale. Operation Manual

SPS-5. Rate Computing Scale. Operation Manual SPS-5 Rate Computing Scale Operation Manual Revision 1.0 October 17, 1996 1996 Transcell Technology, Inc. Contents subject to change without notice. Transcell Technology, Inc. 975 Deerfield Parkway Buffalo

More information

92831 TEL: (714) FAX:

92831 TEL: (714) FAX: Document N0. 1800-03 Copyright 2010 Terra Universal Inc. All rights reserved. Revised Sept. 2010 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton, CA 92831 TEL: (714) 578-6000 FAX:

More information

RK LEL Sample Draw Aspirator Adapter Operator s Manual

RK LEL Sample Draw Aspirator Adapter Operator s Manual 30-0951RK LEL Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0017RK Revision: A Released: 6/2/10 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment

More information

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc. Advanced Calibration Designs, Inc. Calibration Gas Instrument INSTRUCTION MANUAL Release I www.goacd.com Instruction Manual Gas Generator Release I TABLE OF CONTENTS I. General Description Page 2 II. Start-Up

More information

6PS SERIES HERMETIC STAINLESS STEEL PRESSURE SWITCH Introduction

6PS SERIES HERMETIC STAINLESS STEEL PRESSURE SWITCH Introduction 6PS SERIES HERMETIC STAINLESS STEEL PRESSURE SWITCH Introduction KLIXON 6PS series stainless steel pressure switch is a snap-acting, all welded device hermetically sealed switch contacts. All switch components

More information

RK-IR Sample Draw Aspirator Adapter Operator s Manual

RK-IR Sample Draw Aspirator Adapter Operator s Manual 30-0951RK-IR Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0018RK Revision: A Released: 6/2/10 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment

More information

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE INSTALLATION, OPERATION & MAINTENANCE MANUAL INTERFACE DEVICES, INC. 230 Depot Road, Milford, CT 06460 Ph: (203) 878-4648, Fx: (203) 882-0885, E-mail: info@interfacedevices.com

More information

Instruction Manual for Intrinsically Safe - Reed Switches

Instruction Manual for Intrinsically Safe - Reed Switches Instruction Manual for Intrinsically Safe - Reed Switches Option Code: -1S2-IS-LED or -2S2-IS-LED -1S2-IS or -2S2-IS ATEX RCM Industries, Inc. Direct Reading Differential Pressure Flowmeters 110 Mason

More information

Operation Manual. Pro He Alarm TM. Helium Analyzer. Rev 08.17

Operation Manual. Pro He Alarm TM. Helium Analyzer. Rev 08.17 Operation Manual Pro He Alarm TM Helium Analyzer Rev 08.17 If you have any questions on this equipment please contact Technical Support at: Nuvair 1600 Beacon Place Oxnard, CA 93033 Phone: 805-815-4044

More information

PERSONAL AIR BREATHING UNIT

PERSONAL AIR BREATHING UNIT PERSONAL AIR BREATHING UNIT Operation & Maintenance Manual MARTECH SERVICES C O M P A N Y 1-800-831-1525 Table of Contents INTRODUCTION: Page 2 COMPONENTS DRAWING: Page 3 START UP: Page 4 OPERATION: Page

More information

J Air and Water Kit Instructions Part# 02584

J Air and Water Kit Instructions Part# 02584 J Air and Water Kit Instructions Part# 02584 Unpacking Please open and inspect your package upon receipt. Your package was packed with great care and all the necessary packing materials to arrive to you

More information

Owner s Manual Humiport 10/20

Owner s Manual Humiport 10/20 4201 Lien Rd Madison, WI 53704 Owner s Manual Humiport 10/20 Installation, Operation & Service Instructions Read and Save These Instructions The Phoenix Humiport line of ThermoHygrometers offers the restoration

More information

GG-VL2-NH3 AMMONIA VENT LINE SENSOR. Installation and Operation Manual

GG-VL2-NH3 AMMONIA VENT LINE SENSOR. Installation and Operation Manual GG-VL2-NH3 AMMONIA VENT LINE SENSOR Installation and Operation Manual 2 GG-VL2-NH3 Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified

More information

SPECIFICATIONS APCEPH1

SPECIFICATIONS APCEPH1 APCEPH1 ph CONTROLLER SPECIFICATIONS APCEPH1 Input voltage 120 Volts AC Maximum amperage 14.5 amps @ 120 VAC ph Accuracy +/- 0.2 ph ph Control range Adjustable 4.5 8.5 ph Weight < 1 lbs Dimensions 3" x

More information

Data Sheet B-Series Switches Pressure, Differential Pressure & Hydraulic

Data Sheet B-Series Switches Pressure, Differential Pressure & Hydraulic FEATURES Adjustable setpoints 15-100% of range Fixed or limited adjustable deadband Wide selection of switch elements Explosion proof enclosure provides uncompromising protection Special designs for NACE

More information

Operation Manual. Pro CO 2 Analyzer. Carbon Dioxide Analyzer. Rev

Operation Manual. Pro CO 2 Analyzer. Carbon Dioxide Analyzer. Rev Operation Manual Pro CO 2 Analyzer Carbon Dioxide Analyzer Rev. 10.17 Quick Reference Guide READ ENTIRE MANUAL BEFORE USE 1. To switch on, hold the On/Off button until the display powers up. 2. To turn

More information

I/P Transducer Positioner Module

I/P Transducer Positioner Module I/P Transducer Positioner Module VRC P/N: 7958032 Installation, Operation and Maintenance Instructions 2.09 [53.1] 1.30 [32.9] 2.97 [75.5] 0.78 [19.8] 0.18 [4.4] 1.42 [36.1] n.18 MOUNTING HOLES (2) PLACES

More information

HLM-2000-TX Gas Transmitter User Manual

HLM-2000-TX Gas Transmitter User Manual HLM-2000-TX Gas Transmitter User Manual Technical Support Continental North America Toll Free 1-(800) 387-9487 Ph: +1 (905) 829-2418 Fx: +1 (905) 829-4701 A Product of Arjay Engineering Ltd. Oakville,

More information

AUTO PUMP STATUS CENTER

AUTO PUMP STATUS CENTER INSTRUCTION MANUAL AUTO PUMP STATUS CENTER PRESSURE ONLY MODEL #: 091-198-12-AP File: IM_091-198-12-AP_revD.indd Rev: D, pg 3 WD Revised By: PSS Date: 2-01-2016 3 YEAR WARRANTY INTRODUCTION The Auto Pump

More information

INSTALLATION & MAINTENANCE INSTRUCTIONS

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION / IDENTIFICATION The QBX series valve uses Proportion-Air closed loop technology for Pressure control. It gives an output pressure proportional to an electrical command signal input. The QB1X

More information

Gas Pressure Switch for DMV safety shutoff valves

Gas Pressure Switch for DMV safety shutoff valves Gas Pressure Switch for DMV safety shutoff valves GAO-A GMH-A GML-A UL Listed UL File # MH 668 CSA Certified CSA C. No. LR File # 07 FM Approved Class 0, 0 File # J.I. Y9A9.AF Commonwealth of Massachusetts

More information

Data Sheet B-Series Switches Pressure, Differential Pressure & Hydraulic

Data Sheet B-Series Switches Pressure, Differential Pressure & Hydraulic Data Sheet FEATURES Adjustable setpoints 15-100% of range Fixed or limited adjustable deadband Wide selection of switch elements Explosion proof enclosure provides uncompromising protection Special designs

More information

GasSense NDIR User Manual

GasSense NDIR User Manual INDEX INDEX... 1 1. OVERVIEW... 2 2. TECHNICAL DATA... 3 3. SPECIFICATIONS... 4 4. PRODUCT DESCRIPTION... 5 4.1 Mechanical details... 5 4.2 Piping... 7 4.3 Connections... 7 5. INSTALLATION... 10 6. CALIBRATION

More information

COOPER POWER SERIES. Series winding ratio test procedure instructions. Voltage Regulators MN225060EN. 120 Vac VOLTMETER

COOPER POWER SERIES. Series winding ratio test procedure instructions. Voltage Regulators MN225060EN. 120 Vac VOLTMETER Voltage Regulators MN225060EN Effective February 2017 Supersedes January 2012 (S225-60-2) Series winding ratio test procedure instructions COOPER POWER SERIES 120 Vac VOLTMETER S L SL DISCLAIMER OF WARRANTIES

More information

Index Table. Model 794. Installation, Operating and Maintenance Instructions

Index Table. Model 794. Installation, Operating and Maintenance Instructions CLOCKWISE MANUAL MAKING INTO CCW TABLE Index Table Model 794 Installation, Operating and Maintenance Instructions Black & Webster Products Division 545 Hupp Ave. P.O. Box 831, Jackson, Michigan 49204 2009

More information

COOPER POWER SERIES. EL Bay-O-Net Current-Limiting Fuse Installation Instructions. Fusing Equipment MN132023EN

COOPER POWER SERIES. EL Bay-O-Net Current-Limiting Fuse Installation Instructions. Fusing Equipment MN132023EN Fusing Equipment MN132023EN Effective November 2016 Supersedes June 2010 (S240-70-1) EL Bay-O-Net Current-Limiting Fuse Installation Instructions COOPER POWER SERIES DISCLAIMER OF WARRANTIES AND LIMITATION

More information

GASGUARD VENT LINE3 Ammonia Sensor OPERATING & INSTALLATION MANUAL

GASGUARD VENT LINE3 Ammonia Sensor OPERATING & INSTALLATION MANUAL GASGUARD VENT LINE3 Ammonia Sensor OPERATING & INSTALLATION MANUAL Operating and Installation Manual Warning Use this product only in the manner described in this manual. If the equipment is used in a

More information

COOPER POWER SERIES. VariSTAR Storm Trapper high energy MOV arrester installation instructions. Surge Arresters MN235017EN

COOPER POWER SERIES. VariSTAR Storm Trapper high energy MOV arrester installation instructions. Surge Arresters MN235017EN Surge Arresters MN235017EN Effective October 2016 Supersedes S235-16-1 November 2009 COOPER POWER VariSTAR Storm Trapper high energy MOV arrester installation instructions SERIES DISCLAIMER OF WARRANTIES

More information

User s Guide Temperature Sensor Converter TSC-599

User s Guide Temperature Sensor Converter TSC-599 User s Guide Temperature Sensor Converter TSC-599 ILX Lightwave Corporation 31950 Frontage Road Bozeman, MT, U.S.A. 59715 U.S. & Canada: 1-800-459-9459 International Inquiries: 406-556-2481 Fax 406-586-9405

More information

3" UC Ultra-Chuck Durable Lightweight Air Inflated Bladder Chuck Operation/Repair Manual. (76.2 mm) DOUBLE E COMPANY, INC.

3 UC Ultra-Chuck Durable Lightweight Air Inflated Bladder Chuck Operation/Repair Manual. (76.2 mm) DOUBLE E COMPANY, INC. 3" UC-3000 (76.2 mm) Ultra-Chuck Durable Lightweight Air Inflated Bladder Chuck Operation/Repair Manual DOUBLE E COMPANY, INC. 319 Manley Street, West Bridgewater, MA 02379 U.S.A. Tel: (508) 588-8099 /

More information

RTD Temperature sensor TH11

RTD Temperature sensor TH11 RTD Temperature sensor TH11 Compact Instructions Measuring System General purpose RTD with connection head TH11 for process and laboratory applications. The single element RTD is specifi cally designed

More information

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports URC Voltage Sensor SEN-VOLT 2013 Universal Remote Control, Inc. The information in this Owner s Manual is copyright protected.

More information

D Series Air and Water Kit Part# 02550

D Series Air and Water Kit Part# 02550 D Series Air and Water Kit Part# 02550 Unpacking Please open and inspect your package upon receipt. Your package was packed with great care and all the necessary packing materials to arrive to you undamaged.

More information

Model 4000 Pressure Controller

Model 4000 Pressure Controller FEATURES Multiple Configurations The 4000 series pressure controller can be configured into either proportional only or proportional plus reset mode with a minimum of parts. Rugged Design Die cast aluminum

More information

Lock Up Valves YT-400, YT-405 USER'S MANUAL

Lock Up Valves YT-400, YT-405 USER'S MANUAL USER'S MANUAL YTC V.1.01 Product Description Lock Up Valve, YT-400 (YT-405), senses the main supply pressure and shuts down the air flow when the pressure is lower than setting level to avoid system shutdown

More information

MODEL 100 NITROGEN INFLATION CART

MODEL 100 NITROGEN INFLATION CART MODEL 100 NITROGEN INFLATION CART Installation & Operation Information Branick Industries, Inc. 4245 Main Avenue P.O. Box 1937 Fargo, North Dakota 58103 REV120106 P/N: 81-0113 TABLE OF CONTENTS SAFETY

More information

GALISO SOAP OPTION FOR PCT-ADW-D

GALISO SOAP OPTION FOR PCT-ADW-D GALISO SOAP OPTION FOR PCT-ADW-D Installation and Operation Instructions MANUAL NUMBER 21-11-1008 Issued March 2016 Rev B 09/26/2018 Copyright 2016 - Galiso, Incorporated 22 Ponderosa Ct., Montrose, CO

More information

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION The QB3 is a closed loop pressure regulator consisting of two solenoid valves, internal pressure transducer, and electronic controls mounted to an integrated

More information

DK48 - DK800. Quick Start. Variable area flowmeter

DK48 - DK800. Quick Start. Variable area flowmeter Quick Start Variable area flowmeter General safety notes You can find the newest and/or additional information in the handbook, the datasheet, special manuals, certificates and the download center at www.krohne.com.

More information

Autocalibration Systems for In Situ Oxygen Analyzers

Autocalibration Systems for In Situ Oxygen Analyzers Product Data Sheet PDS 106-340AC.A01 February, 2006 SPS 4001B, IMPS 4000 and MPS 3000 Autocalibration Systems for In Situ Oxygen Analyzers Cost-effective autocalibration systems for installations ranging

More information

HLM-2000-TX Gas Transmitter User Manual

HLM-2000-TX Gas Transmitter User Manual HLM-2000-TX Gas Transmitter User Manual Technical Support Continental North America Toll Free 1-(800) 387-9487 Ph: +1 (905) 829-2418 Fx: +1 (905) 829-4701 A Product of Arjay Engineering Ltd. Oakville,

More information

DPC-30 DPC-100. Reference Manual

DPC-30 DPC-100. Reference Manual DPC-30 DPC-100 Reference Manual 1. Introduction 1.1 Description The Martel DPC Digital Pneumatic Calibrator improves upon traditional dial gauge pneumatic calibrators. The Martel DPC improves accuracy,

More information

OWNERS MANUAL. Model Shown with optional Primary Mooring Cleats. Portable Mooring System SAFETY OPERATION MAINTENANCE PARTS

OWNERS MANUAL. Model Shown with optional Primary Mooring Cleats. Portable Mooring System SAFETY OPERATION MAINTENANCE PARTS OWNERS MANUAL Model 2400 Shown with optional Primary Mooring Cleats. Portable Mooring System SAFETY OPERATION MAINTENANCE PARTS CAUTION: Before using your new Pier Tender, read rules for Safety, Operation,

More information

COOPER POWER SERIES. 200 A 15/25 kv class elbow installation instructions. Deadbreak Apparatus Connectors MN650042EN

COOPER POWER SERIES. 200 A 15/25 kv class elbow installation instructions. Deadbreak Apparatus Connectors MN650042EN Deadbreak Apparatus Connectors MN650042EN Effective February 2017 Supersedes December 2009 (S550-10-1) 200 A 15/25 kv class elbow installation instructions COOPER POWER SERIES DISCLAIMER OF WARRANTIES

More information

PPS PORTABLE POWER SUPPLY

PPS PORTABLE POWER SUPPLY PPS User Manual Rev 1-2015 ENG MASTER PPS PORTABLE POWER SUPPLY Disclaimer About ActSafe Safety messages and warnings Product safety System description Pre-use inspection and connection General safety

More information

COOPER POWER SERIES. QD8 Quik-Drive tap-changer VR or VL reversing switch stationary contact assembly kit number A48 installation instructions

COOPER POWER SERIES. QD8 Quik-Drive tap-changer VR or VL reversing switch stationary contact assembly kit number A48 installation instructions Voltage Regulators MN225037EN Effective June 2016 New Issue COOPER POWER SERIES QD8 Quik-Drive tap-changer VR or VL reversing switch stationary contact assembly kit number 5791646A48 installation instructions

More information

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm) Pressure Sensor (Stainless Steel Diaphragm) CSM DS_E_3_1 Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications Incorporates double diaphragms consisting of SUS316L stainless

More information

SPECIFICATIONS ATTENTION

SPECIFICATIONS ATTENTION VPS 504 S06 Installation Manual - P/N 80122 - Ed. 01/09 VPS 504 S06 and S05 Valve Proving System Installation Instructions VPS 1 6 Gases Natural gas, air and other inert gases. NOT suitable for butane

More information

210 Series Transmitter with External Electrochemical Sensor

210 Series Transmitter with External Electrochemical Sensor 210 Series Transmitter with External Electrochemical Sensor INSTRUCTIONS Installation and Operation of the AMC-210 Series Transmitter with External Electrochemical Sensor IMPORTANT: Please read these installation

More information

Operating Instructions

Operating Instructions LPL Series LED Pendant Lighting Operating Instructions IM0102 COOPER Electronic Technologies (Shanghai) Co., Ltd. No. 955 Shengli Road, East Area of Zhangjiang High-Tech Park, Shanghai 201201 China 1.

More information

ASDX Series Silicon Pressure Sensors

ASDX Series Silicon Pressure Sensors ASDX Series Silicon Pressure Sensors DESCRIPTION The ASDX Series is a Silicon Pressure Sensor offering a ratiometric analog interface for reading pressure over the specified full scale pressure span and

More information

9700 Transmitter Submersible hydrostatic level transmitter

9700 Transmitter Submersible hydrostatic level transmitter Specification sheet IP0078 October 2007 Level 9700 Transmitter Submersible hydrostatic level transmitter Description The 9700 series hydrostatic level transmitter is designed to perform in the most arduous

More information

Gas Pressure Switch for DMV safety shutoff valves

Gas Pressure Switch for DMV safety shutoff valves Gas Switch for DMV safety shutoff valves GAO-A GMH-A GML-A UL Listed UL 353 File # MH 1668 CSA Certified CSA C. No. LR 53 File # 0157 FM Approved Class 3510, 3530 File # J.I. 1Y9A9.AF Commonwealth of Massachusetts

More information

Pressure switch for gas and air

Pressure switch for gas and air Pressure switch for gas and air GAO-A4 GMH-A4 GML-A4 UL Listed UL 353 File # MH 16628 CSA Certified CSA C22.2 No. LR 53222 Certification # 201527 FM Approved Class 3510, 3530 File # J.I. 1Y919.AF GXX_A4

More information

Pressure and Vacuum Switches for Process Applications

Pressure and Vacuum Switches for Process Applications for Process Applications Form 216 SOR Pressure are rugged field-mounted instruments. The pressure sensing element of the SOR pressure switch is a force-balance, piston-actuated assembly. The sensing element

More information

MODEL Maverick Heavy Duty Aerosol Compressor Operator s Manual

MODEL Maverick Heavy Duty Aerosol Compressor Operator s Manual MODEL 50012 Maverick Heavy Duty Aerosol Compressor Operator s Manual This page left blank intentionally CONTENTS Page No. INSPECTION... 1 GENERAL INFORMATION... 1 SAFETY PRECAUTIONS... 2 BASIC OPERATING

More information