carefusion.com CareFusion Yorba Linda, CA CareFusion

Size: px
Start display at page:

Download "carefusion.com CareFusion Yorba Linda, CA CareFusion"

Transcription

1 CareFusion Savi Ranch Parkway Yorba Linda, CA toll-free tel fax CareFusion Germany 234 GmbH Leibnizstrasse Hoechberg Germany tel fax CareFusion Yorba Linda, CA carefusion.com 2011 CareFusion Corporation or one of its subsidiaries. All rights reserved. RC (0811/5000) L3250 Rev. C

2 Pocket guide 3100B high frequency oscillatory ventilator

3 This clinician s guide describes equipment set-up and patient management procedures for the 3100B High Frequency Oscillatory Ventilator (HFOV). Warning Do not use this pocket guide as a substitute for (1) reading and understanding the operator s manual, (2) as a substitute for being properly trained or (3) as a substitute for competency using the 3100B High Frequency Oscillatory Ventilator. Use this document as a guideline for initiating and managing the patient on HFOV. Management of a patient on the 3100B HFOV must be altered based on the patient s individual clinical needs. This document is not intended to be used as a substitute for clinical experience or medical guidance. i

4 Contents Indications and contraindications...1 Things to consider before placing the patient on HFOV...4 Pre-use checklist...6 Patient circuit calibration...8 Ventilator performance check...10 Initial settings and management...12 Managing oxygenation and ventilation...16 Assessment of the patient on HFOV...18 Documentation of oscillator settings...21 Weaning HFOV and transitioning to conventional ventilation...22 Transitioning to conventional ventilation...23 Troubleshooting...24 Recruitment maneuvers for adult patients on HFOV...34 Cuff leak procedure...36 Outcome assessment form...41 Useful information...42 ii

5 Indications and contraindications Indications The 3100B High Frequency Oscillatory Ventilator is indicated for use in the ventilatory support and treatment of selected patients weighing 35 kilograms and greater with acute respiratory failure. Contraindications The 3100B High Frequency Oscillatory Ventilator has no specific contraindications. 1

6 Identifying patients for high-frequency oscillatory ventilation Patients with ALI or ARDS, weighing 35 kilograms or greater, who are currently failing on conventional ventilation with a protective lung strategy, will benefit from HFOV. The following criteria are generally used for determining the feasibility of using HFOV. FiO 2 60, PEEP 10 with a P/F ratio < 200 Plateau pressure > 30 cmh 2 O Presence of bilateral infiltrates on the chest x-ray consistent with ARDS Oxygenation index > 24 Note: Several clinical papers and randomized control trials have demonstrated that the earlier application of HFOV on patients with severe ARDS may be important for successful outcomes. 2

7 The Multicenter Oscillatory Ventilation for Acute Respiratory Distress Syndrome Trial 1 (MOAT2) excluded severe COPD and asthma patients from the RCT trial of the 3100B HFOV. High frequency oscillatory ventilation is recognized as less effective in diseases with increased airway resistance and using it in such cases may potentially result in air trapping and hyperinflation. 3

8 Things to consider before placing the patient on HFOV Hemodynamic status: The patient should be hemodynamically stable with a mean arterial pressure of at least 75 mmhg If mean arterial pressure is less than 75 mmhg, consider fluids and/or vasopressors to optimize the hemodynamic status before starting the oscillator Obtain ABG Ideally, ph should be greater than 7.2 If ph is less than 7.2, consider correcting with a buffer for the transition Patient s sedation status: You may need to consider sedation and neuromuscular blockades for transition due to the fixed Bias Flow of the device, patients are unable to actively breathe and maintain a stable airway pressure and lung volume Once transitioned, patients may be able to be maintained on sedation only 4

9 Ensure the patient has had a recent chest x-ray Consider the type of mattress the patient is on you should have the ability to firm up the mattress if needed Verify whether the patient requires an off-unit procedure such as a CT scan or MRI; if this is the case, consider doing the off-unit procedure before placing the patient on HFOV If using an in-line suction catheter, ensure the fit to the circuit and suction patient before placing on HFOV Give a brief explanation of HFOV to the family and patient to prepare them for noise, chest wiggle, etc. If lung recruitment maneuvers are not part of your ventilation protocol, speak with the physician to consider Treatment with Oscillation and Open Lung Strategy (TOOLS) 2 5

10 Pre-use checklist 1. Connect the source gases to system. 2. Connect the power to system. 3. Check that the patient circuit support is installed on the system. 4. Connect the patient circuit and the humidifier to the system. 5. Connect the patient circuit control and pressure sense lines to the system. 6. Turn on the power. 7. Check that the source gas lights are off. 8. Check that the start/stop light is off. 9. Check that the alarm silence light is on. 10. Perform the patient-circuit calibration described in the following section. 11. Perform verification performance. 12. Perform the alarm-check procedure as described in the Operators Manual. 6

11 13. Preset the flow, frequency, % inspiratory time, power and running mean airway pressure. 14. Set the Max Paw and Min Paw switches. 15. Set the blender and humidifier controls for the desired operation. 16. Remove the stopper from the patient circuit and connect it to the patient s ET tube. 7

12 Patient circuit calibration Perform the patient circuit calibration procedure before ventilating a patient. Each circuit that is used on the oscillator must be calibrated. The circuit calibration procedure verifies the circuit is leak-free and will hold pressure. Perform this procedure before placing a patient on the 3100B HFOV and anytime a circuit component is changed. 1. Insert the stopper in the patient circuit wye and turn on the bias flow gas. 2. Rotate the ADJUST control to Max. 3. Set the Max Paw Alarm to 59 cmh 2 O. 4. Set the bias flow to exactly 20 LPM (the middle of the ball is at the line you may need to bend down to see this accurately.). 5. Depress and hold RESET (Oscillator OFF). 8

13 6. Observe the mean pressure display and adjust the patient circuit calibration screw for a reading of 39 to 43 cmh 2 O. a. Before adjusting the calibration screw, confirm there are no leaks, the bias flow is at 20 LPM and the circuit is set up correctly. See the troubleshooting guide for more information. b. Use caution when adjusting the calibration screw. Do not over tighten or apply excessive force because equipment damage may occur. 9

14 Ventilator performance check The ventilator performance check ensures the 3100B HFOV is functioning properly. Perform this procedure before placing a patient on the 3100B HFOV. Insert the stopper in the patient circuit wye and turn on both gas sources. 1. Turn the Adjust control to the 12 o clock position. 2. Set the bias flow at 30 LPM. 3. Pressurize the system by pressing and holding Reset and Adjust for a mean pressure of 29 to 31 cmh 2 O. 4. Set the frequency to 6.0 Hz, % I time to 33 and press START/STOP to start the oscillator. 5. Set the power to Observe the following parameters using the appropriate altitude range and verify they fall within the ranges specified. 10

15 Verify the following parameters according to the altitude of your hospital. Altitude (feet) mpaw (cmh 2 O) P (cmh 2 O) 0 to 2, to to 135 2,000 to 4, to to 125 4,000 to 6, to to 115 6,000 to 8, to to 105 Note: See troubleshooting on pg. 22 for additional information. 11

16 Initial settings and management 1. Set bias flow between 25 to 40 LPM. Patients with severe air-leak syndrome or cuff leak may require higher set Bias Flow to achieve the desired mpaw. 2. Set the initial mean airway pressure (mpaw) at 5 cmh 2 O pressure above the conventional ventilator mpaw. a. You may consider a recruitment maneuver first if the patient is extremely hypoxic by applying 40 cmh 2 O for 40 to 60 seconds. b. If oxygenation worsens, increase mpaw in 3 to 5 cmh 2 O increments every 30 minutes until the maximum setting is reached. Note: Oxygenation typically may worsen in the first 30 minutes of recruitment in severe ARDS. 12

17 c. Check a chest-x-ray within one to four hours of initiating HFOV to assess lung volume. 3. Set the power at 4.0 and rapidly increase it to achieve chest wiggle (a visual vibration from shoulders to mid-thigh area). a. Transcutaneous monitoring for CO 2 (TcCO 2 ) should be considered. b. If PaCO 2 worsens (but ph > 7.2), increase the power setting to achieve a change of amplitude in 10 cmh 2O pressure increments every 30 minutes up to the maximum setting. c. If ph is < than 7.2, consider buffering ph. d. An abrupt rise in PaCO 2 in an otherwise stable patient should be considered an obstruction of the endotracheal tube until proven otherwise. Note: Some studies suggest a higher frequency setting (and corresponding higher amplitude) may be more lung-protective. 13

18 4. Set Hz at a range of 5 to 6 initially. a. You may decrease the Hz if you cannot control the PaCO 2 with amplitude of approximately 90 cmh 2 O. b. Decrease the Hz by 1 Hz at a time every 30 minutes until you reach a level of 3 Hz. 5. Set IT % at 33%. You may increase this value up to 50% if you are unable to ventilate by increasing the amplitude or by first decreasing the frequency. Caution! Using flows higher than 40 LPM may increase the risk of increasing PaCO 2 due to decreasing the effectiveness of the active exhalation. 6. For severe hypercapnea with ph > 7.2, consider decreasing the endotracheal tube cuff inflation to produce a leak. a. Reduce the inflation of the cuff until you see a drop in the mpaw by 5 cmh 2 O. Readjust the bias flow to correct the mpaw level. b. Rule out obstruction in endotracheal tube with bronchoscopy. 14

19 7. Initial FiO 2 at transition to HFOV should be set to 1.0. Alternatively, increase current FiO 2 by 10%. 8. As oxygenation improves, gradually wean FiO 2 to 0.40, and then slowly reduce mpaw 2 to 3 cmh 2 O every four to six hours until mpaw is in a 22 to 24 cmh 2 O range. 9. When the above goal is met (but no sooner than 24 hours), switch to PCV or APRV. Initial settings: PIP titrated to achieve delivered Vt of 6 to 8 ml/kg Plateau Pressure (Pplat): < 35 cmh 2 O I:E of 1:1 PEEP: 12 cmh 2 O Rate: 20 to 25 / min Mean airway pressure should be about 20 cmh 2 O (± 2 cmh 2 O). 15

20 Managing oxygenation and ventilation If h PaO 2 1. Wean FiO 2 slowly (5%) to < Re-check the x-ray for lung volume assessment. If lung volume is adequate, continue to wean FiO 2 to If lung volume is approaching a hyperinflation state, consider weaning mpaw by 1 to 2 cmh 2 O and continue to wean FiO 2 to Once FiO 2 is < 0.40, attempt to wean mpaw by 1 to 2 every four to six hours, ensuring maintenance of adequate lung inflation and oxygenation. If i PaO 2 1. h FiO 2 as needed to h mpaw by 3 to 5 every 20 to 30 minutes to obtain adequate lung inflation and oxygenation. 3. Check the x-ray to ensure appropriate lung volume. 4. Check for hemodynamic status for adequate perfusion. 16

21 If h ph 1. i Power, maintaining adequate chest wiggle factor. 2. h Hz. 3. i % I-time to 33% if at 50%. If i ph 1. h Power, obtaining or maintaining adequate chest wiggle factor. 2. i Hz (minimum of 3.0). 3. Generate ETT leak. 4. h % I-time to 50% if at 33%. hi PaCO 2 1. Accept hypercapnia if ph allows (> 7.2). 2. You may consider buffering ph to allow permissive hypercapnia. 17

22 Assessment of the patient on HFOV ABG Sixty minutes post initiation of HFOV ABG frequency based on clinical status Within one hour of any major settings change or as clinically indicated CXR Within one to four hours post initiation of HFOV Whenever lung over-inflation or under-inflation is suspected 18

23 Patient assessment Patient assessment should be done every two hours and should include the following: 1. Chest wiggle factor (CWF): Visible vibration noted from the shoulder to mid thigh and bilateral. This check ensures movement of air through the airway structure and lung. a. Check for the degree of vibration noted and symmetry. b. Question changes in CWF, for example: Increase with improvement in compliance. Decrease with worsening in compliance or presence of secretions. Noted only on one side of the chest due to ET tube slipping down main bronchus or presence of a pneumothoraces. 2. Auscultation: Breath sounds cannot be heard; however, you may denote changes in the intensity of the piston sounds. 3. Heart and GI sounds: Stop piston temporarily, lung inflation will be maintained. 19

24 4. Vital signs: HR, BP, MAP, urine output, PCWP, PAP and CVP monitoring are not required, but useful tools in ensuring adequate perfusion. 5. Oxygen saturation should be maintained between 88 to 93%. 6. Most FiO 2 changes are made based on improvement in O 2 saturation. 7. Transcutaneous PCO 2, if available, is useful for trending PaCO 2 and indication of ventilatory status change. 8. Monitor for adequate perfusion status by assessing capillary refill, skin turgor and color, urine output change and persistent metabolic acidosis. 9. Secretions will present problems with ventilation if present. Usually secretions are noted by a rapid rise in PaCO 2, a decrease in oxygen saturation and a visible decrease in chest wiggle. 10. If a cuff leak is used, monitor it closely during position changes. You may see changes in amplitude and mpaw reflected on the 3100B HFOV. 20

25 Documentation of oscillator settings Verify and record the ventilator settings (frequency, bias flow, % inspiratory time, power, Max Paw and Min Paw) and measurements (mpaw and amplitude). Note: If mpaw or amplitude measurements change independent of changing a setting, assess for clinical changes, circuit issues or airway issues before dialing for a given measurement. Presence of an intentional cuff leak FiO 2 (must be analyzed) 21

26 Weaning HFOV and transitioning to conventional ventilation When the goals below are met (but no sooner than 24 hours) switch to PCV. FiO 2 is weaned to 0.40 mpaw is 22 to 24 cmh 2O SpO 2 > 88% (or as ordered) The patient should be stable on the above settings and able to tolerate suctioning and brief disconnects. The chest x-ray should show resolution of the underlying process. 22

27 Transitioning to conventional ventilation 1. Use a mode most conducive to the patient; usually PCV/APRV. 2. Set the mean airway pressure to be the same in CMV as on HFOV. 3. Adjust inspiratory pressure to achieve Vt 6 to 10 ml/kg of ideal body weight. 4. Set PEEP, FiO 2 and rate based on most recent ABG. 23

28 Troubleshooting Troubleshooting clinical issues These clinical troubleshooting guidelines are to help orient you to a possible cause for a clinical change. These only address common problems and are by no means all inclusive. 24

29 Problem: The patient experiences an abrupt deterioration (with a rapid rise in PaCO 2 ) while being mechanically ventilated with the high frequency oscillator. Consider the following: Acute airway obstruction (mucous plug) Pneumothorax Bronchospasm Right mainstem intubation or extubation Responses under these circumstances: Assess airway function/patency (e.g., ETT suctioning, auscultation, direct laryngoscopy, tcpco 2 assessment, diminished chest wiggle) Recommend bronchoscopy Draw an ABG if the acute decompensation results in profound hypoxemia (SpO 2 < 80%) or acute hypotension (mean BP drop of > 20 mmhg) Notify the physician of these developments immediately and recommend a stat chest x-ray Consider removing the patient from the oscillator and hand resuscitating 25

30 Problem: The patient experiences an abrupt deterioration with a drop in oxygen saturation. Consider the following: Airway patency Changes in mean arterial pressure Disconnection from the HFOV device with loss of lung volume Possible pneumothorax Responses under these circumstances: Consider fluid boluses and/or pharmacologic support to maintain mean arterial pressure of 75 mmhg or greater Re-check the x-ray to assess or rule out presence of pneumothoraces For an accidental disconnect, consider a recruitment maneuver and/or increase FiO 2 initially 26

31 Problem: Hypotension. Increased intrathoracic pressure from the elevated mpaw may cause decreased blood flow resulting in reduced right ventricular preload. Consider the following: Fluid bolus Pharmacologic support Reduce mpaw 27

32 Troubleshooting equipment issues Circuit does not pass patient circuit calibration Visually check for leaks, cracks and open ports on the circuit Check cap/diaphragms Check the water trap stopcock (may be open or missing) Ensure the circuit set up is correctly Confirm the bias flow is set exactly at 20 LPM (the middle of the ball is at the 20 LPM line you may need to bend down to see this accurately) Check the airway pressure luer fittings for cracks Check the calibration screw (clicking indicates a defective valve) Confirm the pressure transducer zero: With the circuit stopper in place, but the system not pressurized, the Paw should read 0 cmh 2O (± 0.5 cmh 2 O) 28

33 Ventilator does not pass the performance check Low amplitude: Bypass the humidifier Check the power knob (0.0 to 10.0) Low mpaw (with or without low amplitude): Crimp the airway pressure line (mpaw should read 130 to 140 cmh 2 O) Check the flow meter Driver does not start oscillating: Check the power knob Check mpaw Check if the humidifier chamber is empty (may drop the amplitude by as much as 10 cmh 2 O) Bypass the humidifier 29

34 Fluctuating mpaw The Auto-Limit feature is activated Check the high-pressure setting Check for spontaneous breathing Low Source Gas is illuminated This condition indicates an input pressure of less than 30 psi from either the blender or the cooling air; check the input gas lines Ensure that all hoses are plugged into a gas source Check the blender setup configuration Some wye or T fittings used to split the high-pressure line have an internal restriction; remove the wye or T fitting to check it The input water trap filter needs to be replaced: Replace the filter Internal leak: Call CareFusion Technical and Clinical Support 30

35 High Pressure alarms (alarm setting or > 60 cmh 2 O) Spontaneously breathing: Consider the clinical status of the patient, assess the sedation level or insufficient bias flow rate; re-adjust mpaw using a higher flow Obstruction in the expiratory limb or in the pressure sense line: Replace the patient circuit Improper setting of the alarm: Change the alarm setting Patient circuit temperature rise: Check and correct the circuit temperature Interference from a radio transmitter: Remove the source of interference Low Pressure alarms (alarm setting or < 5 cmh 2 O) Spontaneously breathing: Consider the clinical status of the patient, assess sedation level or check for insufficient bias flow rate and re-adjust mpaw using higher flow Improper setting of the alarm: Change the setting Improper setting of the mpaw or flow meter: Change the setting Patient circuit temperature drop: Check and correct the circuit temperature 31

36 Leak in the humidifier or patient circuit: Fix the leak or replace the patient circuit Cap diaphragm leak: Replace the cap diaphragm The water trap stopcock is open: Close the water trap stopcock Interference from a radio transmitter: Remove the source of interference Oscillator stopped with no other alarm occurring The power setting is too low and the amplitude is to 7 cmh 2 O: Adjust setting for desired amplitude Oscillator failure: Call CareFusion Technical and Clinical Support Amplitude changed over the past couple hours while the Power setting remained unchanged Amplitude increased: Airway resistance increased and/or total lung compliance decreased Amplitude decreased: Airway resistance decreased and/or total lung compliance increased 32

37 Changes in amplitude are normal as the patient s pulmonary status changes; assess patient changes in status and adjust ventilator settings if deemed appropriate General guidelines Ventilator circuits should never be reused: Washing and sterilizing will reduce their overall performance and increase the risk of malfunction Use caution when storing ventilator circuits; some components of the circuits may break if compressed tightly Water exiting the exhalation valve is normal; the use of personal protective equipment or the filtered oscillator circuit is encouraged 33

38 Recruitment maneuvers for adult patients on HFOV A recruitment maneuver is a technique employed by attempting to recruit the alveoli and increase lung volume by using a sustained inflation accomplished by a set mpaw of 40 cmh 2 O pressure for 40 seconds with the piston in a stopped position. This technique, when combined with HFOV, is thought to provide further improvements in oxygenation and lung recruitment. 3 Technique: 1. Set FiO 2 to Inflate cuff. 3. Stop the oscillator (START/STOP button). 4. Increase the mpaw to 40 cmh 2 O; then maintain that pressure for 40 seconds. 5. Return to the previous oscillator settings. a. Decrease mpaw. b. Resume oscillation. c. Establish the previous cuff leak. 34

39 Recruitment maneuver guidelines 2 Perform a recruitment maneuver after any circuit disconnect Perform a recruitment maneuver before an increase in mpaw A recruitment maneuver may be repeated up to three times to see improvements in oxygenation with the ability to reduce FiO 2 Caution! Do not perform a recruitment maneuver under either of the following conditions: Pneumothorax is present with an active air leak Patient is hemodynamically unstable, for example: Mean arterial pressure < 60 mmhg or falls > 20 mmhg during the maneuver Heart rate > 140 and < 60 New arrhythmias are noted SpO 2 < 85% 35

40 Cuff leak procedure The cuff leak procedure was identified as a technique that may be employed with HFOV to assist with clearing tracheal dead space of CO 2 and assist with maintaining an adequate ph. Decreasing cuff pressure allows gas (PaCO 2 ) to escape around the ET tube and to be excreted through the mouth. In some cases PaCO 2 can drop by 30 to 40 mmhg (or more). However, it should be noted that if there is an active air leak from a chest tube, the effect of a cuff leak may be minimal or non-existent. CO2 O2 O2 36

41 Indications Power/amplitude and mpaw have been optimized with no net improvement in PaCO 2. Frequency has been lowered to four Hz or less with no improvement in PaCO 2. Inspiratory Time % has been increased with no improvement in PaCO 2. Procedure 1. With a syringe attached to the endotracheal tube pilot balloon, withdraw air. 2. Reduce the inflation of the cuff until you see a drop in the mpaw by approximately 5 cmh 2 O. 3. Increase the bias flow to correct to the desired mpaw level. Monitoring for cuff leak patency If mpaw increases, suction hypopharynx and reassess. If mpaw is lower than desired, reassess and re-adjust the cuff air pressure to the target mpaw level desired. Mean airway pressure may change after patient position changes; reassessment should be done after the change. 37

42 Caution! Before producing a cuff leak consider the following: The patient has been suctioned A bronchoscopy, if possible, was performed to clear airway of any obstruction A recent chest x-ray shows appropriate lung volume. Note that the distal mpaw will be less with cuff deflated even though the monitored mpaw is the same If oxygen saturation drops with this procedure, you may consider increasing mpaw 38

43 Table 1: PaO 2 / FiO 2 ratio < 200 ARDS < 300 ALI < 400 Abnormal > 400 WNL 39

44 Table 1: PaO 2 / FiO 2 ratio (continued) < 200 ARDS < 300 ALI < 400 Abnormal > 400 WNL 40

45 Outcome assessment form The use of this form is not intended to encourage or deny the use of high frequency oscillation. The following below is only a portion of the form. You can find the Outcome Assessment Form to print and use on the CareFusion site at carefusion.com/hfov/. Low risk (zero points) Moderate risk (one point) High risk (two points) Max risk (three points) Days P/F < 200 < 2 days 2-4 days 5-6 days > than 7 days Days of CMV < 6 days > 7 days PaCO < > 80 Organ failures pulmonary only 2 or more PIP < > 50 Immune comp. No Yes OI < > 41 OI trend Slowly Dramatically worsening worsening Oxygenation Index (OI) = [(FiO 2 x 100) x mpaw /PaO 2 ] Score: 1 7 Low anticipated mortality; 8 13 Moderate anticipated mortality; High anticipated mortality Score 41

46 Useful information Clinical and technical support for HFOV Registered respiratory therapists are available for clinical and technical support during normal business hours and for emergency support 24 hours per day. Call and follow the prompts. (For technical support in Canada call ) 3100B HFOV rental program The 3100B HFOV rental program is designed to assist customers who own the 3100B HFOV and need additional units or customers trained on the 3100B HFOV and approved to rent the device as a short term solution to bridge to a purchase. Delivery will be within 24 hours or less in most cases. This program is available 24 hours per day. Call and follow the prompts. 42

47 3100B HFOV intervention program The 3100B HFOV intervention program is designed to allow access to the device for centers that do not have trained personnel or have not maintained competency of the 3100B HFOV. The 3100B HFOV intervention program provides an onsite clinical consultant for education and clinical support. This program must be set up in advance. HFOV website carefusion.com/hfov/ Abbreviations ARDS ALI mpaw Paw Acute Respiratory Distress Syndrome Acute Lung Injury Mean Airway Pressure Mean Airway Pressure display on the 3100B HFOV OI Oxygenation Index: (mpaw x FiO 2 x 100)/PaO 2 P/F ratio PaO 2 / FiO 2 PIP Peak Inspiratory Pressure 43

48 References 1 Derdak S., Mehta S., et al. High Frequency Oscillatory Ventilation for Acute Respiratory Distress Syndrome in Adults: A Randomized, Controlled Trial. Am J Respiratory Critical Care Medicine, 2002; 166: Ferguson N., Chiche J., et al. Combining High-Frequency Oscillatory Ventilation and Recruitment Maneuvers in Adults with Early Acute Respiratory Distress Syndrome. The Treatment with Oscillation and Open Lung Strategy (TOOLS) pilot study. Critical Care Medicine, 2005; 33: Johnson J., Bachman TE. Refining and Validating a Risk Assessment Tool for HFOV Rescue of ARDS Patients. Reparatory Therapy, 2006; 2:

3100A Competency Exam

3100A Competency Exam NAME DATE (Circle the appropriate answer) 3100A Competency Exam 1. Of the following, which best describes the mechanics of ventilation used by the 3100A? a. Active inspiration with passive exhalation b.

More information

Bunnell LifePulse HFV Quick Reference Guide # Bunnell Incorporated

Bunnell LifePulse HFV Quick Reference Guide # Bunnell Incorporated Bunnell Incorporated n www.bunl.com n 800-800-4358 (HFJV) n info@bunl.com 436 Lawndale Drive n Salt Lake City, Utah 84115 n intl 801-467-0800 n f 801-467-0867 Bunnell LifePulse HFV Quick Reference Guide

More information

excellence in care Procedure Management of patients with difficult oxygenation. For Review Aug 2015

excellence in care Procedure Management of patients with difficult oxygenation. For Review Aug 2015 Difficult Oxygenation HELI.CLI.12 Purpose This procedure describes the processes and procedures for a lung protective strategy in the mechanical ventilation of patients that are difficult to oxygenate

More information

Basics of Mechanical Ventilation. Dr Shrikanth Srinivasan MD,DNB,FNB,EDIC Consultant, Critical Care Medicine Medanta, The Medicity

Basics of Mechanical Ventilation. Dr Shrikanth Srinivasan MD,DNB,FNB,EDIC Consultant, Critical Care Medicine Medanta, The Medicity Basics of Mechanical Ventilation Dr Shrikanth Srinivasan MD,DNB,FNB,EDIC Consultant, Critical Care Medicine Medanta, The Medicity Overview of topics 1. Goals 2. Settings 3. Modes 4. Advantages and disadvantages

More information

Mechanical Ventilation

Mechanical Ventilation Mechanical Ventilation Chapter 4 Mechanical Ventilation Equipment When providing mechanical ventilation for pediatric casualties, it is important to select the appropriately sized bag-valve mask or endotracheal

More information

Difficult Oxygenation Distribution: Sydney X Illawarra X Orange X

Difficult Oxygenation Distribution: Sydney X Illawarra X Orange X HELICOPTER OPERATING PROCEDURE HOP No: C/12 Issued: May 2011 Page: 1 of 5 Revision No: Original Difficult Oxygenation Distribution: Sydney X Illawarra X Orange X TRIM No: 09/300 Document No: D10/9973 X

More information

QUICK REFERENCE GUIDE

QUICK REFERENCE GUIDE cm H O 2 cm H O 2 cm HO 2 PSI cm H O 2 ON OFF UPPER LIMIT LOWER LIMIT UPPER LIMIT LOWER LIMIT LIFE PULSE HIGH-FREQUENCY VENTILATOR QUICK REFERENCE GUIDE 01388-08.11 MONITOR PIP JET VALVE ALARMS READY SILENCE

More information

HIGH FREQUENCY JET VENTILATION (HFJV): EQUIPMENT PREPRATION

HIGH FREQUENCY JET VENTILATION (HFJV): EQUIPMENT PREPRATION POLICY The physician orders High Frequency Jet Ventilation (HFJV). The Respiratory Therapist in discussion with the physician will determine blood gas targets and ventilation settings for the treatment

More information

Initiation and Management of Airway Pressure Release Ventilation (APRV)

Initiation and Management of Airway Pressure Release Ventilation (APRV) Initiation and Management of Airway Pressure Release Ventilation (APRV) Eric Kriner RRT Pulmonary Critical Care Clinical Specialist Pulmonary Services Department Medstar Washington Hospital Center Disclosures

More information

AUTOVENT 4000 VENTILATOR

AUTOVENT 4000 VENTILATOR OVERVIEW AUTOVENT 4000 Only properly trained and approved Escambia County Bureau of Public Safety Paramedics are to use the AutoVent 4000 ventilator manufactured by LSP to transport patients already on

More information

VENTILATION STRATEGIES FOR THE CRITICALLY UNWELL

VENTILATION STRATEGIES FOR THE CRITICALLY UNWELL VENTILATION STRATEGIES FOR THE CRITICALLY UNWELL Dr Nick Taylor Visiting Emergency Specialist Teaching Hospital Karapitiya Senior Specialist and Director ED Training Clinical Lecturer, Australian National

More information

VENTILATORS PURPOSE OBJECTIVES

VENTILATORS PURPOSE OBJECTIVES VENTILATORS PURPOSE To familiarize and acquaint the transfer Paramedic with the skills and knowledge necessary to adequately maintain a ventilator in the interfacility transfer environment. COGNITIVE OBJECTIVES

More information

Indications for Mechanical Ventilation. Mechanical Ventilation. Indications for Mechanical Ventilation. Modes. Modes: Volume cycled

Indications for Mechanical Ventilation. Mechanical Ventilation. Indications for Mechanical Ventilation. Modes. Modes: Volume cycled Mechanical Ventilation Eric A. Libré, MD VCU School of Medicine Inova Fairfax Hospital and VHC Indications for Mechanical Ventilation Inadequate ventilatory effort Rising pco2 with resp acidosis (7.25)

More information

INTRODUCTION TO BI-VENT (APRV) INTRODUCTION TO BI-VENT (APRV) PROGRAM OBJECTIVES

INTRODUCTION TO BI-VENT (APRV) INTRODUCTION TO BI-VENT (APRV) PROGRAM OBJECTIVES INTRODUCTION TO BI-VENT (APRV) INTRODUCTION TO BI-VENT (APRV) PROGRAM OBJECTIVES PROVIDE THE DEFINITION FOR BI-VENT EXPLAIN THE BENEFITS OF BI-VENT EXPLAIN SET PARAMETERS IDENTIFY RECRUITMENT IN APRV USING

More information

The Basics of Ventilator Management. Overview. How we breath 3/23/2019

The Basics of Ventilator Management. Overview. How we breath 3/23/2019 The Basics of Ventilator Management What are we really trying to do here Peter Lutz, MD Pulmonary and Critical Care Medicine Pulmonary Associates, Mobile, Al Overview Approach to the physiology of the

More information

NOTE: If not used, provider must document reason(s) for deferring mechanical ventilation in a patient with an advanced airway

NOTE: If not used, provider must document reason(s) for deferring mechanical ventilation in a patient with an advanced airway APPENDIX: TITLE: Mechanical Ventilator Use REVISED: November 1, 2017 I. Introduction: Mechanical Ventilation is the use of an automated device to deliver positive pressure ventilation to a patient. Proper

More information

PERFORMANCE EVALUATION #34 NAME: 7200 Ventilator Set Up DATE: INSTRUCTOR:

PERFORMANCE EVALUATION #34 NAME: 7200 Ventilator Set Up DATE: INSTRUCTOR: PERFORMANCE EVALUATION #34 NAME: 7200 Ventilator Set Up DATE: 1. **Identify and name the filters on the 7200ae. 2. **Explain how each filter is sterilized. 3. **Trace the gas flow through the ventilator

More information

Accumulation of EEV Barotrauma Affect hemodynamic Hypoxemia Hypercapnia Increase WOB Unable to trigger MV

Accumulation of EEV Barotrauma Affect hemodynamic Hypoxemia Hypercapnia Increase WOB Unable to trigger MV Complicated cases during mechanical ventilation Pongdhep Theerawit M.D. Pulmonary and Critical Care Division Ramathibodi Hospital Case I Presentation Male COPD 50 YO, respiratory failure, on mechanical

More information

http://www.priory.com/cmol/hfov.htm INTRODUCTION The vast majority of patients who are admitted to an Intensive Care Unit (ICU) will need artificial ventilation (Jones et al 1998). The usual means through

More information

ONLINE DATA SUPPLEMENT. First 24 hours: All patients with ARDS criteria were ventilated during 24 hours with low V T (6-8 ml/kg

ONLINE DATA SUPPLEMENT. First 24 hours: All patients with ARDS criteria were ventilated during 24 hours with low V T (6-8 ml/kg APPENDIX 1 Appendix 1. Complete respiratory protocol. First 24 hours: All patients with ARDS criteria were ventilated during 24 hours with low V T (6-8 ml/kg predicted body weight (PBW)) (NEJM 2000; 342

More information

Objectives. Respiratory Failure : Challenging Cases in Mechanical Ventilation. EM Knows Respiratory Failure!

Objectives. Respiratory Failure : Challenging Cases in Mechanical Ventilation. EM Knows Respiratory Failure! Respiratory Failure : Challenging Cases in Mechanical Ventilation Peter DeBlieux, MD, FAAEM, FACEP LSUHSC University Hospital Pulmonary and Critical Care Medicine Emergency Medicine pdebli@lsuhsc.edu Objectives

More information

3100B. High frequency oscillatory ventilator. Operator s manual

3100B. High frequency oscillatory ventilator. Operator s manual 3100B High frequency oscillatory ventilator Operator s manual ii 3100B HFOV This document is protected by United States and International Copyright laws. This document may not be copied, reproduced, translated,

More information

PROCEDURE (TASK): ROUTINE VENTILATOR CHECK. 5. Verifies current ventilator Insures correspondence between physician's

PROCEDURE (TASK): ROUTINE VENTILATOR CHECK. 5. Verifies current ventilator Insures correspondence between physician's PROCEDURE (TASK): ROUTINE VENTILATOR CHECK I. KEY PERFORMANCE ELEMENTS Procedural Element (Step): Description of Performance: 5. Verifies current ventilator Insures correspondence between physician's settings

More information

Lung recruitment maneuvers

Lung recruitment maneuvers White Paper Lung recruitment maneuvers Assessment of lung recruitability and performance of recruitment maneuvers using the P/V Tool Pro Munir A Karjaghli RRT, Clinical Application Specialist, Hamilton

More information

Selecting the Ventilator and the Mode. Chapter 6

Selecting the Ventilator and the Mode. Chapter 6 Selecting the Ventilator and the Mode Chapter 6 Criteria for Ventilator Selection Why does the patient need ventilatory support? Does the ventilation problem require a special mode? What therapeutic goals

More information

OPEN LUNG APPROACH CONCEPT OF MECHANICAL VENTILATION

OPEN LUNG APPROACH CONCEPT OF MECHANICAL VENTILATION OPEN LUNG APPROACH CONCEPT OF MECHANICAL VENTILATION L. Rudo Mathivha Intensive Care Unit Chris Hani Baragwanath Aacademic Hospital & the University of the Witwatersrand OUTLINE Introduction Goals & Indications

More information

RESPIRATORY CARE POLICY AND PROCEDURE MANUAL. a) Persistent hypoxemia despite improved ventilatory pattern and elevated Fl02

RESPIRATORY CARE POLICY AND PROCEDURE MANUAL. a) Persistent hypoxemia despite improved ventilatory pattern and elevated Fl02 The University of Mississippi AND PROCEDURE MANUAL Effective Date: June 30, 1990 Revised Date: December 2009 MANUAL CODE Page 1 of 5 PREPARED BY: Respiratory Care Policy and Procedure Review Committee

More information

EMS INTER-FACILITY TRANSPORT WITH MECHANICAL VENTILATOR COURSE OBJECTIVES

EMS INTER-FACILITY TRANSPORT WITH MECHANICAL VENTILATOR COURSE OBJECTIVES GENERAL PROVISIONS: EMS INTER-FACILITY TRANSPORT WITH MECHANICAL VENTILATOR COURSE OBJECTIVES Individuals providing Inter-facility transport with Mechanical Ventilator must have successfully completed

More information

High Frequency Ventilation. Neil MacIntyre MD Duke University Medical Center Durham NC USA

High Frequency Ventilation. Neil MacIntyre MD Duke University Medical Center Durham NC USA High Frequency Ventilation Neil MacIntyre MD Duke University Medical Center Durham NC USA High frequency ventilation Concept of ventilator induced lung injury and lung protective ventilatory strategies

More information

Neonatal tidal volume targeted ventilation

Neonatal tidal volume targeted ventilation Neonatal tidal volume targeted ventilation Colin Morley Retired Professor of Neonatal Medicine, Royal Women s Hospital, Melbourne, Australia. Honorary Visiting Fellow, Dept Obstetrics and Gynaecology,

More information

Presentation Overview. Monitoring Strategies for the Mechanically Ventilated Patient. Early Monitoring Strategies. Early Attempts To Monitor WOB

Presentation Overview. Monitoring Strategies for the Mechanically Ventilated Patient. Early Monitoring Strategies. Early Attempts To Monitor WOB Monitoring Strategies for the Mechanically entilated Patient Presentation Overview A look back into the future What works and what may work What s all the hype about the WOB? Are ventilator graphics really

More information

HOBIT Trial Checklist

HOBIT Trial Checklist ED INITIAL IDENTIFICATION AND NOTIFICATION OF HOBIT TRIAL PATIENTS HOBIT eligibility met pending head CT results If patient has pacemaker/aicd/insulin pump/other implantable device, verify that the device

More information

Mechanical Ventilation

Mechanical Ventilation PROCEDURE - Page 1 of 5 Purpose Scope Physician's Order Indications Procedure Mechanical Artificial Ventilation refers to any methods to deliver volumes of gas into a patient's lungs over an extended period

More information

QUICK GUIDE: VOLUME GUARANTEE VENTILATION Prematurely Born Infants < Weeks Gestation

QUICK GUIDE: VOLUME GUARANTEE VENTILATION Prematurely Born Infants < Weeks Gestation Initial Set-up QUICK GUIDE: VOLUME GUARANTEE VENTILATION Prematurely Born Infants < 32 +0 Weeks Gestation Mode: SIPPV + VG Tidal volume: 4-5 ml/kg Pmax (PIP limit): 25 cmh 2 O PEEP: 5 cmh 2 O & Insp. time

More information

Mechanical Ventilation of the Patient with ARDS

Mechanical Ventilation of the Patient with ARDS 1 Mechanical Ventilation of the Patient with ARDS Dean Hess, PhD, RRT, FAARC Assistant Professor of Anesthesia Harvard Medical School Assistant Director of Respiratory Care Massachusetts General Hospital

More information

Advanced Ventilator Modes. Shekhar T. Venkataraman M.D. Professor Critical Care Medicine and Pediatrics University of Pittsburgh School of Medicine

Advanced Ventilator Modes. Shekhar T. Venkataraman M.D. Professor Critical Care Medicine and Pediatrics University of Pittsburgh School of Medicine Advanced Ventilator Modes Shekhar T. Venkataraman M.D. Shekhar T. Venkataraman M.D. Professor Critical Care Medicine and Pediatrics University of Pittsburgh School of Medicine Advanced modes Pressure-Regulated

More information

Instructions/Procedure for Use of the Speaking Valve

Instructions/Procedure for Use of the Speaking Valve Instructions/Procedure for Use of the Speaking Valve Notes on the use of the speaking valve for ventilator-dependent and non-ventilator dependent patients The speaking valve is a one-way valve that allows

More information

Operator s Manual. 3100B High Frequency Oscillatory Ventilator

Operator s Manual. 3100B High Frequency Oscillatory Ventilator Operator s Manual 3100B High Frequency Oscillatory Ventilator Part Number 767164-101 Revision L Copyright VIASYS Critical Care Division 2002 Revision History Date Revision Changes January 1993 A Initial

More information

Virginia Beach EMS. Oxylator EMX. Debra H. Brennaman, RN, MPA, NREMT-P

Virginia Beach EMS. Oxylator EMX. Debra H. Brennaman, RN, MPA, NREMT-P Virginia Beach EMS Oxylator EMX Debra H. Brennaman, RN, MPA, NREMT-P Oxylator EMX Overview Patient responsive oxygen powered resuscitation / ventilation device intended to provide emergency ventilatory

More information

Notes on BIPAP/CPAP. M.Berry Emergency physician St Vincent s Hospital, Sydney

Notes on BIPAP/CPAP. M.Berry Emergency physician St Vincent s Hospital, Sydney Notes on BIPAP/CPAP M.Berry Emergency physician St Vincent s Hospital, Sydney 2 DEFINITIONS Non-Invasive Positive Pressure Ventilation (NIPPV) Encompasses both CPAP and BiPAP Offers ventilation support

More information

5/9/2017. Definition & Description. HFOV Rationale, Physiology, & Applications. Definition & Description. Rationale. High Frequency Ventilation Types

5/9/2017. Definition & Description. HFOV Rationale, Physiology, & Applications. Definition & Description. Rationale. High Frequency Ventilation Types High Frequency Oscillatory Ventilation Learning Objectives Explain the indications, rationale & monitoring for HFOV Explain the effects of adjusting HFOV ventilator controls Arthur Jones EdD, RRT This

More information

Mechanical Ventilation. Flow-Triggering. Flow-Triggering. Advanced Concepts. Advanced Concepts in Mechanical Ventilation

Mechanical Ventilation. Flow-Triggering. Flow-Triggering. Advanced Concepts. Advanced Concepts in Mechanical Ventilation Mechanical Ventilation Advanced Concepts in Mechanical Ventilation Flow-Triggering Trigger = the variable that causes the vent to begin the inspiratory phase Common triggers 1-2- 3- Effort required to

More information

4/2/2017. Sophisticated Modes of Mechanical Ventilation - When and How to Use Them. Case Study 1. Case Study 1. ph 7.17 PCO 2 55 PO 2 62 HCO 3

4/2/2017. Sophisticated Modes of Mechanical Ventilation - When and How to Use Them. Case Study 1. Case Study 1. ph 7.17 PCO 2 55 PO 2 62 HCO 3 Sophisticated Modes of Mechanical entilation - When and How to Use Them Dr. Leanna R. Miller DNP, RN, CCRN-CMC, PCCN-CSC, CEN, CNRN, CMSRN, NP LRM Consulting Nashville, TN Case Study 1 A 55 year-old man

More information

Endotracheal Suctioning: In Line ETT

Endotracheal Suctioning: In Line ETT Approved by: Endotracheal Suctioning: In Line ETT Gail Cameron Senior Director Operations, Maternal, Neonatal & Child Health Programs Dr. Paul Byrne Medical Director, Neonatology Neonatal Policy & Procedures

More information

The Crossvent 2i+ 2. Ventilator Concept (brief theory of operation and features)

The Crossvent 2i+ 2. Ventilator Concept (brief theory of operation and features) The Crossvent 2i+ 1. How is this ventilator classified 2. Ventilator Concept (brief theory of operation and features) -Your Two Choices with this Ventilator 3. An overview of the device (an in-service)

More information

Disclosures. The Pediatric Challenge. Topics for Discussion. Traditional Anesthesia Machine. Tidal Volume = mls/kg 2/13/14

Disclosures. The Pediatric Challenge. Topics for Discussion. Traditional Anesthesia Machine. Tidal Volume = mls/kg 2/13/14 2/13/14 Disclosures Optimal Ventilation of the Pediatric Patient in the OR Consulting Draeger Medical Jeffrey M. Feldman, MD, MSE Division Chief, General Anesthesia Dept. of Anesthesiology and Critical

More information

CCAT Mechanical Ventilation Clinical Practice Guideline

CCAT Mechanical Ventilation Clinical Practice Guideline CCAT Mechanical Ventilation Clinical Practice Guideline Initial publication date: Mar 2012 Last update: 22 Oct 2013 I. Background and Introductory Information A. Mechanical ventilation can injure the lung.

More information

Flight Medical presents the F60

Flight Medical presents the F60 Flight Medical presents the F60 Reliable Ventilation Across the Spectrum of Care Adult & Pediatric Pressure/Volume Control Basic/Advanced Modes Invasive/NIV High Pressure/Low Flow O2 Up to 12 hours batteries

More information

Astral in AirView: Improving patient care through connectivity. ResMed.com

Astral in AirView: Improving patient care through connectivity. ResMed.com Astral in AirView: Improving patient care through connectivity ResMed.com This guide will assist you with: Setting up the ResMed Connectivity Module for Astral 2 Troubleshooting the ResMed Connectivity

More information

Astral in AirView: Improving patient care through connectivity. ResMed.com

Astral in AirView: Improving patient care through connectivity. ResMed.com Astral in AirView: Improving patient care through connectivity ResMed.com Using Astral in AirView via the ResMed Connectivity Module (RCM) Astral is ResMed s portable, invasive and non-invasive life support

More information

RESPIRATORY PHYSIOLOGY, PHYSICS AND PATHOLOGY IN RELATION TO ANAESTHESIA AND INTENSIVE CARE

RESPIRATORY PHYSIOLOGY, PHYSICS AND PATHOLOGY IN RELATION TO ANAESTHESIA AND INTENSIVE CARE Course n : Course 3 Title: RESPIRATORY PHYSIOLOGY, PHYSICS AND PATHOLOGY IN RELATION TO ANAESTHESIA AND INTENSIVE CARE Sub-category: Intensive Care for Respiratory Distress Topic: Pulmonary Function and

More information

Capnography in the Veterinary Technician Toolbox. Katie Pinner BS, LVT Bush Advanced Veterinary Imaging Richmond, VA

Capnography in the Veterinary Technician Toolbox. Katie Pinner BS, LVT Bush Advanced Veterinary Imaging Richmond, VA Capnography in the Veterinary Technician Toolbox Katie Pinner BS, LVT Bush Advanced Veterinary Imaging Richmond, VA What are Respiration and Ventilation? Respiration includes all those chemical and physical

More information

Pressure Controlled Modes of Mechanical Ventilation

Pressure Controlled Modes of Mechanical Ventilation Pressure Controlled Modes of Mechanical Ventilation Christopher Junker Department of Anesthesiology & Critical Care Medicine George Washington University Saturday, August 20, 2011 Assist Control Hypoxemic

More information

Mechanical Ventilation. Mechanical Ventilation is a Drug!!! is a drug. MV: Indications for use. MV as a Drug: Outline. MV: Indications for use

Mechanical Ventilation. Mechanical Ventilation is a Drug!!! is a drug. MV: Indications for use. MV as a Drug: Outline. MV: Indications for use Mechanical Ventilation is a Drug!!! Mechanical Ventilation is a drug I am an employee of Philips Healthcare Hospital Respiratory Care Group and they help me pay for my kids education Jim Laging, RRT, RCP

More information

PART EIGHT HIGH FREQUENCY PERCUSSIVE OSCILLATION (HFPOV )

PART EIGHT HIGH FREQUENCY PERCUSSIVE OSCILLATION (HFPOV ) PART EIGHT HIGH FREQUENCY PERCUSSIVE OSCILLATION (HFPOV ) Note: For maximal comparative understanding, FIRST read PART SEVEN which defines the concept of High Frequency Oscillatory Ventilation (HFOV).

More information

Hallowell EMC 2000 and 2002 Veterinary Ventilator Set-up, Use, and Troubleshooting

Hallowell EMC 2000 and 2002 Veterinary Ventilator Set-up, Use, and Troubleshooting Hallowell EMC 2000 and 2002 Veterinary Ventilator Set-up, Use, and Troubleshooting This is a quick reference for setting up, using, and troubleshooting the Hallowell EMC 2000 and 2002 Small Animal Ventilator.

More information

The ARDSnet and Lung Protective Ventilation: Where Are We Today

The ARDSnet and Lung Protective Ventilation: Where Are We Today The ARDSnet and Lung Protective Ventilation: Where Are We Today 4-16-12 RCSW Bob Kacmarek PhD, RRT Harvard Medical School Massachusetts General Hospital Boston, Massachusetts Conflict of Interest Disclosure

More information

APRV: Moving beyond ARDSnet

APRV: Moving beyond ARDSnet APRV: Moving beyond ARDSnet Matthew Lissauer, MD Associate Professor of Surgery Medical Director, Surgical Critical Care Rutgers, The State University of New Jersey What is APRV? APRV is different from

More information

HONG KONG COLLEGE OF ANAESTHESIOLOGISTS TECHNICAL GUIDINES RECOMMENDATIONS ON CHECKING ANAESTHESIA DELIVERY SYSTEMS

HONG KONG COLLEGE OF ANAESTHESIOLOGISTS TECHNICAL GUIDINES RECOMMENDATIONS ON CHECKING ANAESTHESIA DELIVERY SYSTEMS RECOMMENDATIONS ON CHECKING ANAESTHESIA DELIVERY SYSTEMS 1. INTRODUCTION An anaesthesia delivery system includes any machine, equipment or apparatus which supplies gases, vapours, local anaesthesia and/or

More information

Chapter 4: Ventilation Test Bank MULTIPLE CHOICE

Chapter 4: Ventilation Test Bank MULTIPLE CHOICE Instant download and all chapters Test Bank Respiratory Care Anatomy and Physiology Foundations for Clinical Practice 3rd Edition Will Beachey https://testbanklab.com/download/test-bank-respiratory-care-anatomy-physiologyfoundations-clinical-practice-3rd-edition-will-beachey/

More information

How does HFOV work? John F Mills MBBS, FRACP, M Med Sc, PhD Neonatologist Royal Children s Hospital. Synopsis

How does HFOV work? John F Mills MBBS, FRACP, M Med Sc, PhD Neonatologist Royal Children s Hospital. Synopsis How does HFOV work? John F Mills MBBS, FRACP, M Med Sc, PhD Neonatologist Royal Children s Hospital Synopsis Definition of an oscillator Historical perspective Differences between HFOV and CMV Determinants

More information

A Multi-centre RCT of An Open Lung Strategy including Permissive Hypercapnia, Alveolar Recruitment and Low Airway Pressure in

A Multi-centre RCT of An Open Lung Strategy including Permissive Hypercapnia, Alveolar Recruitment and Low Airway Pressure in The PHARLAP Study A Multi-centre RCT of An Open Lung Strategy including Permissive Hypercapnia, Alveolar Recruitment and Low Airway Pressure in The PHARLAP Study Investigators for the ANZICS Clinical Trials

More information

POWERPRESS UNIT. User Manual. Gradient Pneumatic Sequential Compressor. Neomedic

POWERPRESS UNIT. User Manual. Gradient Pneumatic Sequential Compressor. Neomedic TIMER (MIN) POWERPRESS UNIT 40 70 40 80 90 10 60 100 MIN MAX PRESSURE (mmhg) User Manual Neomedic 9601 Owens mouth Ave. #8 Chatsworth, CA 91311 Toll Free: 866-990-1168 Tel: 818-998-1023 Fax: 818-998-0277

More information

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator Operating Instructions Table of Contents Resource v.2 Conserving Regulator Safety Information Device Precautions Introduction Product Features Product Specifications Feature Illustrations Set Up Usage

More information

UNDERSTANDING NEONATAL WAVEFORM GRAPHICS. Brandon Kuehne, MBA, RRT-NPS, RPFT Director- Neonatal Respiratory Services

UNDERSTANDING NEONATAL WAVEFORM GRAPHICS. Brandon Kuehne, MBA, RRT-NPS, RPFT Director- Neonatal Respiratory Services UNDERSTANDING NEONATAL WAVEFORM GRAPHICS Brandon Kuehne, MBA, RRT-NPS, RPFT Director- Neonatal Respiratory Services Disclosures Purpose: To enhance bedside staff s knowledge of ventilation and oxygenation

More information

Working version subject to Departmental approval. Drafted by Dr. Olympio and reviewed by clinical members of The Capital Equipment Committee

Working version subject to Departmental approval. Drafted by Dr. Olympio and reviewed by clinical members of The Capital Equipment Committee Wake Forest University Baptist Medical Center Department of Anesthesiology TECHNICIAN ABBREVIATED CHECKLIST OF RESPONSIBILITIES For Anesthesia Apparatus Checkout Specific to the Draeger APOLLO anesthesia

More information

Test Bank for Pilbeams Mechanical Ventilation Physiological and Clinical Applications 6th Edition by Cairo

Test Bank for Pilbeams Mechanical Ventilation Physiological and Clinical Applications 6th Edition by Cairo Test Bank for Pilbeams Mechanical Ventilation Physiological and Clinical Applications 6th Edition by Cairo Link full download: http://testbankair.com/download/test-bank-for-pilbeams-mechanicalventilation-physiological-and-clinical-applications-6th-edition-by-cairo/

More information

Automatic Transport Ventilator

Automatic Transport Ventilator Automatic Transport Ventilator David M. Landsberg, MD, FACP, FCCP, EMT-P Luke J. Gasowski, RRT, NPS, ACCS, CCP-C, FP-C Christopher J. Fullagar, MD, FACEP, EMT-P Stan Goettel, MS, EMT-P Author credits /

More information

Health Professional Info

Health Professional Info Health Professional Info Mouthpiece Ventilation (MPV) What is MPV? MPV is a less intrusive form of noninvasive ventilation that uses a portable home mechanical ventilator (HMV) with a single-limb open-circuit

More information

Mechanical Ventilation

Mechanical Ventilation Mechanical Ventilation Understanding Modes Rob Chatburn, RRT-NPS, FAARC Research Manager Respiratory Therapy Cleveland Clinic Associate Professor Case Western Reserve University 1 Overview Characteristics

More information

Clinical Skills. Administering Oxygen

Clinical Skills. Administering Oxygen Clinical Skills Administering Oxygen Updated July 2017 Clare Cann Original 2012 Carole Loveridge, Lecturer in Women`s Health Aims and Objectives Aims and Objectives The aim of this module is to facilitate

More information

The aim of this guideline is to describe the indications and procedure for using high flow nasal prong oxygen

The aim of this guideline is to describe the indications and procedure for using high flow nasal prong oxygen High flow nasal prong HFNP oxygen therapy o Introduction & aim o Indications o Contraindications o Management equipment setup patient management o Weaning o Complications Introduction Humidified high flow

More information

DRAFT U S E R M A N U A L CAUTION. Model: 19MFA1001 Series. Federal (USA) law restricts this device to sale by or on the order of a physician.

DRAFT U S E R M A N U A L CAUTION. Model: 19MFA1001 Series. Federal (USA) law restricts this device to sale by or on the order of a physician. U S E R M A N U A L Model: 19MFA1001 Series SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician. 300 Held Drive Tel: (+001) 610-262-6090 Northampton,

More information

Completed downloadable Test Bank for Pilbeams Mechanical Ventilation Physiological and Clinical Applications 5th Edition by Cairo

Completed downloadable Test Bank for Pilbeams Mechanical Ventilation Physiological and Clinical Applications 5th Edition by Cairo Completed downloadable Test Bank for Pilbeams Mechanical Ventilation Physiological and Clinical Applications 5th Edition by Cairo Link full download: http://testbankcollection.com/download/pilbeams-mechanicalventilation-physiological-and-clinical-applications-5th-edition-test-bank-cairo

More information

Operation and Maintenance of the EPV200 Portable Ventilator

Operation and Maintenance of the EPV200 Portable Ventilator Operation and Maintenance of the EPV200 Portable Ventilator 1 Applications of the EPV200 The EPV200 Portable Ventilator is a gas powered electronically controlled mechanical ventilator, designed to provide

More information

Invasive mechanical ventilation:

Invasive mechanical ventilation: Invasive mechanical ventilation definition mechanical ventilation: using an apparatus to facilitate transport of oxygen and CO2 between the atmosphere and the alveoli for the purpose of enhancing pulmonary

More information

Mechanical Ventilation. Which of the following is true regarding ventilation? Basics of Ventilation

Mechanical Ventilation. Which of the following is true regarding ventilation? Basics of Ventilation Mechanical Ventilation Jeffrey L. Wilt, MD, FACP, FCCP Associate Professor of Medicine Michigan State University Associate Program Director MSU-Grand Rapids Internal Medicine Residency Which of the following

More information

VT PLUS HF performance verification of Bunnell Life-Pulse HFJV (High Frequency Jet Ventilator)

VT PLUS HF performance verification of Bunnell Life-Pulse HFJV (High Frequency Jet Ventilator) VT PLUS HF performance verification of Bunnell Life-Pulse HFJV (High Frequency Jet Ventilator) VT PLUS HF provides a special mode for evaluating the performance of high frequency ventilators while connected

More information

Respiratory Signs: Tachypnea (RR>30/min), Desaturation, Shallow breathing, Use of accessory muscles Breathing sound: Wheezing, Rhonchi, Crepitation.

Respiratory Signs: Tachypnea (RR>30/min), Desaturation, Shallow breathing, Use of accessory muscles Breathing sound: Wheezing, Rhonchi, Crepitation. Respiratory Signs: Tachypnea (RR>30/min), Desaturation, Shallow breathing, Use of accessory muscles Breathing sound: Wheezing, Rhonchi, Crepitation. Paradoxical breathing Hyper-resonance on percussion:

More information

6 th Accredited Advanced Mechanical Ventilation Course for Anesthesiologists. Course Test Results for the accreditation of the acquired knowledge

6 th Accredited Advanced Mechanical Ventilation Course for Anesthesiologists. Course Test Results for the accreditation of the acquired knowledge 6 th Accredited Advanced Mechanical Ventilation Course for Anesthesiologists Course Test Results for the accreditation of the acquired knowledge Q. Concerning the mechanics of the newborn s respiratory

More information

Operating Instructions for Microprocessor Controlled Ventilators

Operating Instructions for Microprocessor Controlled Ventilators Page 1 of 5 Operating Instructions for Microprocessor Controlled Ventilators Purpose Audience Scope Physician's Order To provide guidelines for the procedure for the use of microprocessor controlled ventilators.

More information

3. Mean airway pressure (MAWP) is characteristically lower in HFOV compared to conventional ventilation.

3. Mean airway pressure (MAWP) is characteristically lower in HFOV compared to conventional ventilation. Sign up to receive ATOTW weekly - email worldanaesthesia@mac.com HIGH FREQUENCY OSCILLATORY VENTILATION ANAESTHESIA TUTORIAL OF THE WEEK 261 28 TH MAY 2012 Dr Sarah Jarvis, Mrs Karen Burt and Dr William

More information

How to use the SAVe II Ventilator

How to use the SAVe II Ventilator TRAININGGROUNDS How to use the SAVe II Ventilator Designed to elevate the standard of care and improve triage capabilities simply select the height of the patient to deliver a targeted tidal volume. This

More information

Volume Diffusion Respiration (VDR)

Volume Diffusion Respiration (VDR) Volume Diffusion Respiration (VDR) A therapy with many uses Jeffrey Pietz, MD April 15, 2016 VDR ventilation has been used to treat patients with: ARDS Meconium Aspiration Burn and Inhalation Injury RDS

More information

Driving Pressure. What is it, and why should you care?

Driving Pressure. What is it, and why should you care? Driving Pressure What is it, and why should you care? Jonathan Pak MD March 2, 2017 Lancet 1967; 290: 319-323 Traditional Ventilation in ARDS Tidal Volume (V T ) = 10-15 ml/kg PBW PEEP = 5-12 cm H 2 O

More information

Manual: Biphasic Positive Airway Pressure (BiPAP) Ventilation

Manual: Biphasic Positive Airway Pressure (BiPAP) Ventilation RCH@Home Manual: Biphasic Positive Airway Pressure (BiPAP) Ventilation 1. Commonly used terms... 2 1.1 Inspiration... 2 1.2 Expiration... 2 1.3 Breath rate (bpm)... 2 1.4 Ventilation... 2 1.5 Biphasic

More information

TESTCHEST RESPIRATORY FLIGHT SIMULATOR SIMULATION CENTER MAINZ

TESTCHEST RESPIRATORY FLIGHT SIMULATOR SIMULATION CENTER MAINZ TESTCHEST RESPIRATORY FLIGHT SIMULATOR SIMULATION CENTER MAINZ RESPIRATORY FLIGHT SIMULATOR TestChest the innovation of lung simulation provides a breakthrough in respiratory training. 2 Organis is the

More information

Trust Guideline for Neonatal Volume Guarantee Ventilation (VGV)

Trust Guideline for Neonatal Volume Guarantee Ventilation (VGV) A Clinical Guideline For Use in: By: For: Division responsible for document: Key words: Name of document author: Job title of document author: Name of document author s Line Manager: Job title of author

More information

Ventilating the Sick Lung Mike Dougherty RRT-NPS

Ventilating the Sick Lung Mike Dougherty RRT-NPS Ventilating the Sick Lung 2018 Mike Dougherty RRT-NPS Goals and Objectives Discuss some Core Principles of Ventilation relevant to mechanical ventilation moving forward. Compare and Contrast High MAP strategies

More information

Author: Thomas Sisson, MD, 2009

Author: Thomas Sisson, MD, 2009 Author: Thomas Sisson, MD, 2009 License: Unless otherwise noted, this material is made available under the terms of the Creative Commons Attribution Non-commercial Share Alike 3.0 License: http://creativecommons.org/licenses/by-nc-sa/3.0/

More information

Unit 15 Manual Resuscitators

Unit 15 Manual Resuscitators 15-1 Unit 15 Manual Resuscitators GOAL On completion of this unit, the student should comprehend the proper operation of self-inflating resuscitation bags, flow-inflating resuscitation bags and gas-powered

More information

Standards and guidelines for care and management of patients requiring oxygen therapy.

Standards and guidelines for care and management of patients requiring oxygen therapy. PURPOSE Standards and guidelines for care and management of patients requiring oxygen therapy. STANDARDS Ongoing management of oxygen therapy requires a prescriber s order. The order must specify oxygen

More information

New Frontiers in Anesthesia Ventilation. Brent Dunworth, MSN, CRNA. Anesthesia Ventilation. New Frontiers in. The amount of gas delivered can be

New Frontiers in Anesthesia Ventilation. Brent Dunworth, MSN, CRNA. Anesthesia Ventilation. New Frontiers in. The amount of gas delivered can be New Frontiers in Anesthesia Ventilation Senior Director, Nurse Anesthesia Department of Anesthesiology University of Pittsburgh Medical Center Content Outline 1 2 Anesthesia Evolution Anesthesia Evolution

More information

Recommendations on Checking Anaesthesia Delivery Systems

Recommendations on Checking Anaesthesia Delivery Systems Page 1 of 11 Recommendations on Checking Anaesthesia Delivery Version Effective Date 1 Oct 1992 (reviewed Feb 07, Feb 02) 2 2004 3 Nov 2011 4 Dec 2016 Document No. HKCA T1 v4 Prepared by College Guidelines

More information

Introduction to Conventional Ventilation

Introduction to Conventional Ventilation Introduction to Conventional Ventilation Dr Julian Eason Consultant Neonatologist Derriford Hospital Mechanics Inspiration diaphragm lowers and thorax expands Negative intrathoracic/intrapleural pressure

More information

Invasive Ventilation: State of the Art

Invasive Ventilation: State of the Art ARDSnet NEJM 2000;342:1301 9-30-17 Cox Invasive Ventilation: State of the Art Bob Kacmarek PhD, RRT Harvard Medical School Massachusetts General Hospital Boston, Massachusetts A V T of 6 ml/kg PBW results

More information

Principles of mechanical ventilation. Anton van Kaam, MD, PhD Emma Children s Hospital AMC Amsterdam, The Netherlands

Principles of mechanical ventilation. Anton van Kaam, MD, PhD Emma Children s Hospital AMC Amsterdam, The Netherlands Principles of mechanical ventilation Anton van Kaam, MD, PhD Emma Children s Hospital AMC Amsterdam, The Netherlands Disclosure Research grant Chiesi Pharmaceuticals Research grant CareFusion GA: 27 weeks,

More information

How Ventilators Work. Chapter 3

How Ventilators Work. Chapter 3 How Ventilators Work Chapter 3 To care for a ventilator patient, you need to know: The various functions of the ventilator used How the ventilator interacts with the patient How changes in lung condition

More information

CPR MEDICAL DEVICES INC. OPERATING MANUAL FOR RESUSCITATOR

CPR MEDICAL DEVICES INC. OPERATING MANUAL FOR RESUSCITATOR CPR MEDICAL DEVICES INC. OPERATING MANUAL FOR OXYLATOR FR-300 RESUSCITATOR Symbols used in the Operating Manual for the Oxylator FR-300 and/or on the Oxylator FR-300 unit: WARNING! Do not use grease or

More information

Medical Instruments in the Developing World

Medical Instruments in the Developing World 2.2 Ventilators 2.2.1 Clinical Use and Principles of Operation Many patients in an intensive care and the operating room require the mechanical ventilation of their lungs. All thoracic surgery patients,

More information