Supratec von-drais-straße 7 D Simmern/Hunsrück Fon: *49 ( ) Fax: *49 ( )
|
|
- Cathleen Snow
- 6 years ago
- Views:
Transcription
1 BELÜFTUNGSTECHNIK UMWELT- & VERFAHRENSTECHNIK SERVICE & WARTUNG G E N E R A L I N F O R M A T I O N OXYFLEX - MF 650 MEMBRAN-PLATE-DIFFUSER for fine bubble aeration of liquids Supratec GESELLSCHAFT FÜR UMWELT- UND VERFAHRENSTECHNIK MBH von-drais-straße 7 D Simmern/Hunsrück Fon: *49 ( ) Fax: *49 ( ) info@supratec.cc internet:
2 G E N E R A L Supratec I N F O R M A T I O N GENERAL INFORMATION Supratec Gesellschaft für Umwelt- und produces modern high efficient aeration systems, which are mainly used for oxygen transfer into biological waste water treatment. These products can also be used for any kind of transfer of gases into liquids. OXYFLEX is the brand of membrane diffusers (plate, tubes and discs) with a plastic body. The extra ordinary charachteristics of OXYLFEX -MF membrane plate diffusers are given by its shape and the materials used. DESIGN MEMBRANE OXYFLEX -MF membrane plate diffusers are available in two sizes: OXYFLEX -MF 650 (width length) 650 mm 150 mm and OXYFLEX -MF 1100 (width length) 1100 mm 200 mm. The body is a oval plate, made of glass reinforced made of Polypropylene. The membrane is fixed to this body with a plastic frame also made of glass reinforced Polypropylene. Standard membranes are made of SUPRAFORM (EPDM). Membranes made of SUPRASIL (Silicone) and SUPRADUR (Polyurethane) are also available. The membranes have a unique slot-arrangment. The size and arrangement of those slots is optimized to archieve maximum oxygen transfer efficiency. CHARACTERISTICS OXYFLEX -MF membrane plate diffusers have low pressure loss. OXYFLEX -MF membrane plate diffusers are highly resitant against soiling. OXYFLEX -MF membrane plate diffusers produce fine bubbles of a medium diameter < 2 mm. Unlike tube diffusers, the whole active diffuser surface is at the same hydraulic level, therefore the membranes operate evenly across the full range from minimal to maximal air flow. The feature results in optimum lifetime and efficiency. OXYFLEX -MF membrane plate diffusers can be operated intermittently. OXYFLEX -MF membrane plate diffusers can be installed with plastic- and/or stainless steel pipes and are used for all geometric forms of tanks, but they are extraordinarily good for medium and huge sized tanks. PERFORMANCE OXYFLEX -MF membrane plate diffusers are well established and are working to the clients satisfaction world-wide. OXYFLEX -MF membrane plate diffusers have a very wide range, OXYFLEX -MF 650: 0-1Nm /h. The design air flow should be approximately, OXYFLEX -MF 650: 7 ± 2 Nm /h OXYFLEX -MF membrane plate diffusers can reach specific oxygen transfer efficiency up to 25 go /Nm xm, if coverage and water depth is favourable. 2 sup COMBINATION VARIATIONS For plants with partly intermittent operated tanks, OXYFLEX -MF membrane plate diffusers can be combined with BRANDOL ceramic tube diffusers. However, different pressure losses have to be considered. Modifed OXYFLEX -MF membrane plate diffusers are also available for drinking water purposes. OXYFLEX -MF membrane plate diffusers are also available as coarse bubble diffusers. Supratec von-drais-straße 7 D Simmern Fon: +49 ( ) Fax: +49 ( ) info@supratec.cc
3 D R A W I N G O X Y F L E X - M F A S Membrane Plate Diffuser OXYFLEX -MF 650 Type AS will be mounted onto distributor with a welded clamp (different diameter available). Materials: Body: Polypropylen (PP-GF) : Polypropylen (PP-GF) Clamp: Polypropylen (PP) Gasket: EPDM Membrane: SUPRASIL (Silikon) SUPRAFORM (EPDM) Membrane area: 0,1 m² Membrane Body Distributor Pipe Gasket Thread Connection Hole Ø 14mm Clamp 2 Pieces Hole Ø 14mm Distribution Pipe Distributor in different diameter e.g. Dn100, DN80 2 Pieces Clamp Membrane Supratec von-drais-straße 7 D Simmern Fon: +49 ( ) Fax: +49 ( ) info@supratec.cc
4 D R A W I N G O X Y F L E X - M F B Membrane Plate Diffuser OXYFLEX -MF 650 Type B will be installed to a rectangular pipe by 4 welded thread bolts, those are welded to the pipe. Materials: Body: Polypropylen (PP-GF) : Polypropylen (PP-GF) Gasket: EPDM Membrane: SUPRASIL (Silikon) SUPRAFORM (EPDM) Membrane area: 0,1 m² Membrane Body plate Distributor Pipe Gasket Air-Socket Hole Ø 2mm 2 Pieces Threat bolts M6 Hole in Pipe Ø 2mm Distributor Pipe 2 Pieces Membrane Stand Juni 2009 Supratec von-drais-straße 7 D Simmern Fon: +49 ( ) Fax: +49 ( ) info@supratec.cc
5 C U R V E S P R E S S U R E - O X Y G E N OXYFLEX -MF650 membrane plate diffuser are high efficient diffusers and are mainly used for oxygen supply to biological waste water treatment plants. Beside procedural necessities, important criterions are used to select the matching fine-bubble aeration-technology to the features of a treatment plant. Systems using OXYFLEX -MF650 membrane plate diffusers are typically designed at a specific air-flow of 7 Nm /h per unit. This gives a good compromise between capital in investment and efficiency. The following table shows figures taken from an actual oxygen efficiency test. The values have been reached in a circular basin with water depth of 4,5m, submergence of diffusers of 4,15m and coverage of 11,27%. These are typical values particular to the test basin. The figures can deviation ± 25% in tanks of different sizes and diffuser density and loading. SUPRATEC GmbH would be pleased to produce a data-sheet for any individual application on request. No guarantee-claims can be derived from the diagram! 0 specific O 2-entrainment standard conditions and pressure loss OXYFLEX -Mf p OC OCL,h [go2/(nm³ x met)] p [mbar] specific load [Nm³/m] 10 Supratec von-drais-straße 7 D Simmern Fon: +49 ( ) Fax: +49 ( ) info@supratec.cc
6 I N S T A L L A T I O N Supratec M A N U A L DESCRIPTION OXYFLEX -MF650 - membrane plate diffuser Type AS has a solid, strong, horizontal body, made of glass-reinforced Polypropylene and a slipped over membrane (e.g. EPDM). The two-piece-frame, made of glass-reinforced Polypropylene ensures the proper location of the membrane. The body has a connecting-thread (standard 1 BSPmale) that is welded into a Polypropylene clamp. This clamp can be fastened by screws or wedges. The integral gasket of the clamp seals the system. MEASUREMENTS Width: 189 mm, Length: 680 mm, Height: 21 mm - with rounded edges (not including clamp) 2 Free membrane area: Length: 650 mm, Width: 150 mm (0,1 m ) STORAGE PREPARATION The diffusers should be stored in their packing inside a dry and aerated building. DIN 7716 has to be considered. Before installation of the OXYFLEX -MF membrane plate diffuser Type AS it has to be checked that the piping system is clean. Drilling chips, dirt etc. have to be removed, as those will be transported into the diffusers as soon as blowers are set into operation causing serious damage to the diffuser membranes. LEVELLING INSTALLATION OXYFLEX -MF membrane plate diffuser Type AS normally installed onto round pipes. The piping system has to be levelled to maximum ± 10 mm. OXYFLEX -MF membrane plate diffuser Type AS can be fixed to round pipes made of stainless steel or plastic, with a minimum diameter of 50 mm. On the upper side of those pipes, centred holes of diameter Ø 14 mm must be made. The clamp will be installed in such a way, that the hole of Ø 14 mm and the opening of the clamp are aligned. Care must be taken of the horizontal seat of the diffusers. The O-Ring seal, made of EPDM must be clean and undamaged and should sit between diffuser and pipe. Supratec von-drais-straße 7 D Simmern Fon: +49 ( ) Fax: +49 ( ) info@supratec.cc
7 O P E R A T I O N M A N U A L FUNCTION AND LEAKAGE CHECK FIRST RUN OF DIFFUSERS VISUAL BUBBLE CHECK OXYGEN- TRANSFER- EFFICIENCY TEST START UP After installation of OXYFLEX -MF 650 membrane plate diffusers a function and leakage test should be carried out. The tank should be filled with clean water up to maximum 10 cm above diffusers surface and the diffusers set in operation (specific air flow: 6 Nm /h per unit). Then function and installation can be checked and confirmed by report. After function and installation has been checked and confirmed OXYFLEX -MF 650 membrane plate diffusers have to be operated at least another 60 hours continuously, at a specific air flow of minimum 10 Nm /h per unit. Water level shall be as quickly as possible raised up to minimum 100 cm above diffusers surface. IMPORTANT: Diffusers should not stand still Specific air flow should not exceed 1 Nm /h per unit. The visual judgement of the bubble distribution should not be taken before the above specific first run of diffusers. To do the visual check, the diffusers shall operate at maximum capacity and shall be turned to the minimum. Test of even aeration (visual bubble check) must take place when the water level is at least cm above diffusers surface and a specific air flow of at least 6 Nm /h per unit. Test of even aeration (visual bubble check) at minimum air flow can only take place if the water temperature is above 10 C. Before the stated oxygen transfer efficiency figures of the OXYFELX - MF 650 membrane plate diffusers are proved with an oxygen transfer efficiency test, the above mentioned steps have to be considered. The oxygen transfer efficiency test must be done accordingly to accepted rules (e.g. ATV-M 209) in clean or waste water. Guarantee figures have to be controlled exactly. It is necessary to have a precise air-flow measurement system. After successful oxygen transfer efficiency test, start up of the OXYFLEX -MF 650 membrane plate diffusers may follow immediately. If there is a postponement of the start up, care should be taken that the water level stays at least 100 cm above diffusers surface to protect OXYFLEX -MF 650 membrane plate diffusers from sunlight and / or freezing. Supratec von-drais-straße 7 D Simmern Fon: +49 ( ) Fax: +49 ( ) info@supratec.cc
8 M A I N T E N A N C E M A N U A L MAINTENANCE OXYFLEX -MF 650 membrane plate diffusers do not need a lot of maintenance. Usually it is enough to have one run of 10 to 15 minutes operation at minimum air-flow per day, where each single OXYFLEX -MF 650 membrane plate diffuser shall operate at a specific air-flow of at least 10 Nm /h per unit. To do so, it may help to shut down the system partially, by closing the corresponding valves. This removes layers of sludge which may have occurred after long times of in operation of the system or long times of low specific air flow. At least once per year OXYFLEX - MF 650 membrane plate diffusers should be checked visually, particulary they should be checked for layers of sludge or similar. If so, those layers should be removed carefully. A seperate maintenance-contract is available. SUPERVISION A Visual bubble check should be carried out daily. The pressure loss of the system should be monitored and reported monthly. Apparent changes of the bubble distribution and/or of the pressure loss should be promptly reported to SUPRATEC GmbH, especially at installations with intermittent operation where there is a risk that activated sludge could penetrate the entire piping through a damaged OXYFLEX -MF 650 membrane plate diffuser which would affect function and lifetime of all OXYFLEX -MF 650 membrane plate diffusers in the system. The maximum of SUPRATEC GmbH s warranty for OXYFLEX -MF 650 membrane is 24 months. Longer warranty can be arranged only with conclusion of a maintenance contract between the operator and SUPRATEC GmbH. Damage and/or other influences are specifically excluded from the warranty promise. WARRANTY The warranty ends if it is known, that sewage is partially or mainly of industrial origin and/or the sewage has a damaging influence on membrane diffusers and SUPRATEC GmbH was not informed accordingly. In such a case, a confirmation of the warranty is to be ordered through SUPRATEC GmbH. The general sales and warranty conditions of SUPRATEC GmbH apply. Supratec von-drais-straße 7 D Simmern Fon: +49 ( ) Fax: +49 ( ) info@supratec.cc
Supratec. MEMBRANE-PLATE-DIFFUSER For fine bubble aeration of liquids BELÜFTUNGSTECHNIK UMWELT- & VERFAHRENSTECHNIK SERVICE & WARTUNG
BELÜFTUNGSTECHNIK UMWELT- & VERFAHRENSTECHNIK SERVICE & WARTUNG G E N E R A L I N F O R M A T I O N OXYFLEX - MF 1100 For fine bubble aeration of liquids Supratec GESELLSCHAFT FÜR U MWELT- U N D VERFAHRENSTECHNIK
More informationSupratec. von-drais-straße 7 D Simmern/Hunsrück Fon: +49 ( 67 61) Fax: +49 ( 67 61)
O X Y FLEX - OM O VA L-MEMBRANE-TUBE-DIFFUSER for fine bubble aeration of liquids UND GESELLSCHAFT FÜR UMWELT- VERFAHRENSTECHNIK mbh von-drais-straße 7 D-55469 Simmern/Hunsrück Fon: +49 ( 67 61) 9 65 09-00
More informationSupratec Gesellschaft für Umweltund Verfahrenstechnik mbh OXYFLEX - M T / M T M E M B R A N E D I S C D I F F U S ER AERATION TECHNOLOGY
OXYFLEX - M T 2 3 5 / M T 3 0 0 M E M B R A N E D I S C D I F F U S ER UND GESELLSCHAFT FÜR UMWELT- VERFAHRENSTECHNIK MBH AERATION TECHNOLOGY von-drais-straße 7 D-55469 Simmern / Hunsrück Tel.: +49 6761
More informationSupratec AERATION TECHNOLOGY. von-drais-straße 7 D Simmern / Hunsrück. tel.: / fax: /
PERMOX OM120 Oval Membrane Tu b e D i ffuser w i th stainless steel b o d y Supratec for fine bubble or coarse bubble diffusion of liquids Supratec UND GESELLSCHAFT FÜR UMWELT- VERFAHRENSTECHNIK MBH AERATION
More informationaeration and mixing systems
1 air diffusers The Zenit range includes both disc and tube membrane air diffusers. Both models are fitted with high-quality membranes with perforation ensuring high oxygen transfer with low headloss.
More informationDisc diffuser ELASTOX -T
Pioneering for You Series documentation version 12/2016 2 Application ƒƒfor fine-bubble compressed air aeration within the biological treatment stage ƒƒdepending on application and basin geometry: Use
More informationPanel diffuser ELASTOX -P
Pioneering for You Series documentation version 12/2016 2 Application ƒƒfor fine-bubble compressed air aeration within the biological treatment stage ƒƒdepending on application and basin geometry: Use
More informationRAUBIOXON PLUS Pipe Aerator
RAUBIOXON PLUS Pipe Aerator Technical Information 316 TI-E Technical modifications reserved Contents Page 1. Areas of application 1 2. RAUBIOXON PLUS pipe aerator 2 2.1 Components 2 2.2 Material property
More informationFINE BUBBLE DISC DIFFUSER
FINE BUBBLE DISC DIFFUSER AIRSPEC MARKETING SDN BHD (Co.No. 582313-H) No.21 & 23, Jalan 2/152, Taman Perindustrian OUG, Batu 6, Jalan Puchong, 58200 Kuala Lumpur. Malaysia. Tel: 603-7783 7082 (Hunting
More informationOperating instructions - Translation of the original -
Operating instructions - Translation of the original - 5093 xxx 000-xxx Check valve DN25 - DN100 EPDM O-Ring-design Intermediate flanged with welding ends 27.1.12 KIESELMANN GmbH Paul-Kieselmann-Str.4-10
More informationPressure Reducing Valve DMV 750
ASV Stübbe GmbH & Co. KG Hollwieser Straße 5 D-32602 Vlotho Fon +49 (0) 57 33-7 99-0 Fax +49 (0) 57 33-7 99-2 00 www.asv-stuebbe.de contact@asv-stuebbe.de Pressure Reducing Valve DMV 750 Advantages reduction
More informationDICTATOR "DIREKT" Gate Closer
DICTATOR "DIREKT" Gate Closer For Access Gates in Boundary Fences The DICTATOR gate closer DIREKT is the economic solution for the controlled closing of outside gates, such as admission gates to kinder
More informationInstructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO
Instructions for Use Plug connection for medical gas and vacuum acc. to DIN 13260-2 / 2004 DIN EN ISO 9170-1 Table of Contents Page 1. MANUFACTURER S DATA... 3 2. INTRODUCTION... 4 3. APPLICATION... 5
More informationPressure Reducing Valve
ASV Stübbe GmbH & Co. KG Hollwieser Straße 5 D-32602 Vlotho Fon +49 (0) 57 33-7 99-0 Fax +49 (0) 57 33-7 99-2 00 www.asv-stuebbe.de contact@asv-stuebbe.de Advantages high reproducibility of setting pressure
More informationOperating instructions - Translation of the original -
Operating instructions - Translation of the original - 5091 xxx 000-xxx Check valve (O-Ring - design) DN 10 - DN 100, DN 1inch - DN 4inch EPDM Male part - welding end (G-S) 23.2.12 KIESELMANN GmbH Paul-Kieselmann-Str.4-10
More informationPressure Reducing Valve DMV 755
Pressure Reducing Valve DMV 755 Nominal size DN 10 50 Nominal size 3/8 2 Nominal pressure PN 10 bar Features pressure setting range 1 to 9 bar control valve for reliable reduction of system pressures to
More informationArmatures for analytical probes
Armatures for analytical probes For many different types of installations and applications Large range of probe holders General purpose, water treatment, food & beverage, pharmaceutical applications Type
More informationInstruction presentation Special valves
Instruction presentation Special valves 1 Special Valves 2 Special Valves Index of contents 1. Overview special valves 2. Description Gauge Guard 3. Description Water Jet Pumps 4. Description Venting and
More informationPressure relief valve DHV 716 set range: 0,5-10,0 bar
Pressure relief valve DHV 7 set range: 0,5-0,0 bar Advantage pressure setting possible at any time, also during operation optimum monitoring valves high reproducibility of the set pressure high level of
More informationPressure Reducing Valve DMV 750 set range: bar
Pressure Reducing Valve DMV 750 set range:.0-6.0 bar Advantage pressure setting possible at any time, also during operation hermetically sealed by valve diaphragm high level of operating safety and long
More informationRS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.
RS(H)10,15 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to
More informationFORMIC ACID DOSING STATION
Gesellschaft für Umweltund Verfahrenstechnik mbh Von-Drais-Straße 7 D-55469 Simmern/Hunsrück FORMIC ACID DOSING STATION phone: +49-6761 96509-00 fax: +49-6761 96509-01 e-mail: info@oxyflex.de internet:
More informationAVK SERIES 601, 602, 603 & 605 UNIVERSAL COUPLINGS, ADAPTORS & END CAPS INSTALLATION, OPERATION & MAINTENANCE MANUAL
Instruction for use Thank you for selecting an AVK product. With correct use, the product is guaranteed to deliver a long and reliable service. This manual has been prepared to assist you with the installation,
More informationTechnical Bulletin 161. How Deep Can I Design my Aeration Tanks? by:
Technical Bulletin 161 How Deep Can I Design my Aeration Tanks? by: Environmental Dynamics International Published: 01/2017 BULLETIN BRIEF In the water and wastewater treatment field there are many needs
More informationValves. Diaphragm shut-off valves, kidney-type
Valves Diaphragm shut-off valves, kidney-type Application When leakage of even the smallest quantities must be avoided with certainty For maximum requirements to operating safety For maximum requirements
More informationRAUBIOXON AND RAUBIOFLEX AERATOR SYSTEMS TECHNICAL INFORMATION
RAUBIOXON AND RAUBIOFLEX AERATOR SYSTEMS TECHNICAL INFORMATION www.rehau.com Subject to technical modifications Valid from September 14 REHAU REDEFINING QUALITY IN POLYMERS WORLDWIDE RAUBIOXON AND RAUBIOFLEX
More informationOPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER
OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER Table of contents 1 Security and safety measures... 5 1.1 General safety instructions... 5 1.2 Intended use... 5 1.3 Danger zones and residual
More information400V 50Hz. Tsurumi TRN. Submersible aerator. Auto-suction submersible aerator for communal and industrial waste water clearance and treatment.
Tsurumi TRN 400V Hz Submersible aerator Auto-suction submersible aerator for communal and industrial waste water clearance and treatment. TRN-submersible aerator The Tsurumi TRN-submersible aerator is
More informationPressure relief valve DHV 725 set range: 0,2-10,0 bar
Pressure relief valve DHV 75 set range: 0, - 0,0 bar Advantage pressure setting possible at any time, also during operation optimum monitoring valves high reproducibility of the set pressure high level
More informationPressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar
Pressure relief valve DHV 7 DN 5-80: 0,5-0 bar, DN 5-00: 0, - bar, DN 00: 0,5 - bar Advantage for high pressure stability reliable reduction of pressure peaks and pulsations pressure setting possible at
More informationTechnical Bulletin 160. Maximum Air Pressure for Diffusers. by:
Technical Bulletin 160 Maximum Air Pressure for Diffusers by: Environmental Dynamics International Published: 11/2016 BULLETIN BRIEF In the design and application of diffuser systems, it is important to
More informationMounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2
Self-operated Pressure Regulator Pressure Reducing Valve Type M 44-2 Type M 44-2, connection G 1 4, K VS = 0.15 Type M 44-2, connection G 1, K VS = 6 Fig. 1 Type M 44-2 Pressure Reducing Valve Mounting
More informationOXYGEN and SYSTEM OXY
OXYGEN and SYSTEM OXY Used to mix the treated liquid with air allowing a high degree of oxygen exchange Particularly indicated for an efficient oxigenation in waste water treatment plant as well as industrial
More informationExpert Hydrostatic Level Transmitters
Expert Hydrostatic s General Features MJK Expert hydrostatic level transmitters are designed for level measurement by submerging the transmitter in open channels, drains and tanks. Expert hydrostatic level
More informationType BBS-03, BBS-05, BBS-06, BBS-25
Type BBS-03, BBS-05, BBS-06, BBS-25 Sterile connection elements Sterile Verbindungselemente Raccords union stériles Operating Instructions Bedienungsanleitung Manuel d utilisation 1. THE OPERATING INSTRUCTIONS
More informationFloat operated valve TYPE (SWDS)
Float operated valve TYPE (SWDS) Assembly and Operating Instructions for all models Float operated valve Type SWDS Assembly and Operating Instructions Rev.0 Page 1 of 12 Table of Contents 1 General 3 2
More informationDICTATOR "DIREKT" Gate Closer
DICTATOR "DIREKT" Gate Closer For Access Gates in Boundary Fences The DICTATOR gate closer DIREKT is the economic solution for the reliable and controlled closing of outside gates, such as admission gates
More informationMounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25
Self-operated Pressure Regulators Differential Pressure Regulators (opening) Type 42-20 Type 42-25 Type 42-20 Differential Pressure Regulator Type 42-25 Differential Pressure Regulator Mounting and Operating
More informationPressure Relief Valve DHV 718
Pressure Relief Valve DHV 718 Nominal size DN 8 50 Nominal size 3/8 2 Nominal pressure PN 10 bar Features pressure setting range 0.5 to 10 bar diaphragm controlled pressure relief valve simple design,
More informationPRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.
PRS(TC)4,8 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to
More informationOperating instruction
Operating instruction MV, XV, HG, HP, RKO, D2G, TV, BV, WB & SLV 1 Introduction 2 2 Stafsjö s knife gate valves 2 3 Technical information 2 3.1 Pressure test 2 3.2 Labelling 2 4 Storage 3 5 Transportation
More informationMounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity
Type 4708-45 Supply Pressure Regulator with increased air capacity Translation of original instructions Mounting and Operating Instructions EB 8546-1 EN Edition March 2016 Note on these mounting and operating
More informationTA-COMPACT-P. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve (PIBCV)
Combined control & balancing valves for small terminal units Pressure independent balancing and control valve (PIBCV) IMI TA / Control valves / The pressure independent balancing and control valve ensures
More informationOperating instructions - Translation of the original -
Operating instructions - Translation of the original - Overflow valves Typ 5076 DN 10 - DN100 KIESELMANN GmbH Paul-Kieselmann-Str.4-10 D - 75438 Knittlingen +49 (0) 7043 371-0 Fax: +49 (0) 7043 371-125
More informationbetter measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.
Simply a question of better measurement SCHMIDT Flow Sensor SS 20.261 The cost-effective alternative in pressurised systems up to 10 bars. Compressed air technology Industrial processes A cost analysis
More informationFITTINGS AND VALVES Düker Plunger Valve RKV Type 7015 Professional control of flow rates, reservoir levels and pressures Safe, hygienic and durable!
FITTINGS AND VALVES Düker Plunger Valve RKV Type 7015 Professional control of flow rates, reservoir levels and pressures Safe, hygienic and durable! 1 The New Düker Plunger Valve Type 7015 St Plunger valves
More informationSiphon vessel / Priming aid
Manufacturer: sera GmbH sera-straße 1 34376 Immenhausen Germany Tel.: +49 5673 999-00 Fax: +49 5673 999-01 info@sera-web.com Keep the operating manual for future use! Record the exact type and serial number
More informationGas Pressure Regulator HON 300
Gas Pressure Regulator HON 300 OPERATING AND MAINTENANCE INSTRUCTIONS/ SPARE PARTS Serving the Gas Industry Worldwide 300.20 EDITION 01/2017 1. General The "General description 300.00" for the gas pressure
More informationPressure Reducing Valve DMV 755 set range: 1,0-9,0 bar
Pressure Reducing Valve DMV 755 set range:,0-9,0 bar Advantage pressure setting possible at any time, also during operation high reproducibility of the set pressure high level of operating safety and long
More informationSelf-operated Pressure Regulators for special applications
Self-operated Pressure Regulators for special applications Type 2357-31 Pressure Build-up Regulator with safety function and integrated excess pressure valve Application Pressure regulators for cryogenic
More informationOPTIPOW 105 OPTIPOW 105 ; MAIN PARTS. Our Ref: PSE, Bernt Andersson
Page 1 (6) Our Ref: PSE, Bernt Andersson OPTIPOW 105 OPTIPOW 105, the compact pulse valve for the Optipulse fabric filters of different types: is a result of many years of experiences within the fabric
More informationPressure Equalising Valves Model , for Differential Pressure Gauges
Accessories Pressure Equalising Valves Model 910.25, for Differential Pressure Gauges WIKA Data Sheet AC 09.11 Applications T Isolating, pressure equalising as well as purging and air bleeding valves to
More informationINSTALLATION INSTRUCTIONS FOR SSI WIDEBAND DIFFUSER
INSTALLATION INSTRUCTIONS FOR SSI WIDEBAND DIFFUSER Comment Sheet: 1. Installation, Operation and Maintenance Manual contains detailed information on the SSI-Cap Diffuser unit. This manual covers start-up,
More informationOperating instructions - Translation of the original -
Operating instructions - Translation of the original - 3-way ball cock Type 403x KIESELMANN GmbH Paul-Kieselmann-Str.4-10 D - 75438 Knittlingen +49 (0) 7043 371-0 Fax: +49 (0) 7043 371-125 www.kieselmann.de
More informationJohnston Invar Coupling Johnston Invar Coupling
Johnston Invar Coupling Rev.10 (2017.07) AvdS Page 1 of 8 Table of contents I. STRUCTURE OF THE MANUAL / CLARIFICATION... 3 II. SAFETY AND HEALTH CONCERNS... 4 1 GENERAL REMARK... 5 2 ASSEMBLY INSTRUCTIONS...
More informationBTV. Internally threaded 2-way control valve. Flow characteristics. Function
Internally threaded 2-way control valve The valves are designed for control of hot, cold or glycol-mixed water in heating and ventilation systems. They are pressure balanced (from DN20-50, not DN15) and
More informationINSTALLATION, OPERATION AND MAINTENANCE GUIDE
INSTALLATION, OPERATION AND Placement in Pipeline System When installing Process Development & Control s ElastoTITE Elastomer-Hinged Check Valves in a pipeline, a minimum of five pipe diameters should
More informationMeasurement of Low GAS & Liquid Flows
Measurement of Low GAS & Liquid Flows The Measurement Measurement with a float in a tapered borosilicate glass tube. Series 2100 with a 100 mm flow tube Series 2150 with a 150 mm flow tube Series 2300
More informationTBV-CM. Combined control & balancing valves for small terminal units For modulating control
TBV-CM Combined control & balancing valves for small terminal units For modulating control IMI TA / Control valves / TBV-CM TBV-CM Designed for use in terminal units in heating and cooling systems, the
More informationInstructions for use Compressed air injector with water trap
Instructions for use Compressed air injector with water trap Table of Contents Introduction 1. Description of Functions 2. Putting into Operation 3. Instructions for Cleaning and Care 3.1 Disassembling
More informationCVS10 Sanitary Check Valves
0299050/4 IM-P029-11 ST Issue 4 CVS10 Sanitary Check Valves Installation and Maintenance Instructions 1. Safety information CVS10 with soft seat 2. General product information 3. Operation 4. Installation
More informationAKIT1901LM (Metal levers) AKIT1901XM (Cross Handles)
PALLADIAN EXPOSED TUB SET WITH HANDSHOWER AKIT1901LM (Metal levers) AKIT1901XM (Cross Handles) COLORS/FINISHES WARRANTY FEATURES Palladian metal levers or cross handles Floor mounted exposed two handle
More informationType 4708 Supply Pressure Regulator
Type 478 Pressure Regulator Application pressure regulator used to provide pneumatic measuring and control equipment with a constant air supply Set point ranges. to.6 bar ( to 4 psi) or. to 6 bar (8 to
More informationTechnical Bulletin 148. Comparison of Flat Panel to MiniPanel. by:
Technical Bulletin 148 Comparison of Flat Panel to MiniPanel by: Environmental Dynamics International Published: 6/2005 BULLETIN BRIEF Environmental Dynamics International offers a full spectrum of fine
More informationTHE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401
THE MF-400 SERIES Operating and Service Manual Series includes all variants of MF-400/401 Issue A October 2013 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 4. Special
More informationMounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators
Supply Pressure Regulator Type 4708 Type 4708-5352 on Type 3730 Positioner Type 4708-52 with filter receptacle Type 4708-6252 on Type 3372 ctuator Fig. Supply pressure regulators Mounting and Operating
More informationTubes Components Valves Units Engineering SO EVERYTHING KEEPS FLOWING. Safety valves Bunging valves Vacuum valves Tank dome fittings
SO EVERYTHING KEEPS FLOWING Safety valves Bunging valves Vacuum valves Tank dome fittings Reliable reaction at the right moment Safety components are part of our everyday life. Like anti-skid systems in
More informationSTAD. Balancing valves DN 15-50
STAD Balancing valves DN 15-50 IMI TA / Balancing valves / STAD STAD The STAD balancing valve delivers accurate hydronic performance in an impressive range of applications. Ideally suited for use on the
More informationPressure Relief Valve DHV 718
Advantages frictionless components low maintenance low pressure increase up to fully opened valve constant low vibration controlling hermetically sealed by diaphragm for oscillating pumps for viscous media
More informationDifferential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting
Data sheet Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting Description AVPQ is a self-acting differential pressure and flow controller primarily for use in
More informationPressure relief valve DHV 718
Pressure relief valve DHV 78 Benefits diaphragm controlled pressure relief valve with piston guidance simple design, reliable function particularly suitable for oscillating pumps constant, frictionless
More informationTBV-CM. Combined control & balancing valves for small terminal units For modulating control NPT threads
TBV-CM Combined control & balancing valves for small terminal units For modulating control NPT threads IMI TA / Control valves / TBV-CM TBV-CM Designed for use in terminal units in heating and cooling
More informationHOVAP SERIES 9600 BASICFLOW PROCESS VALVES INSTRUCTION MANUAL
1 CONTENTS 2 Introduction 2 2.1 Valve use 2 2.2 Application area 2 2.3 Incorrect use 2 3 Safety 2 4 Transport and storage 2 5 Installation instructions 2 5.1 Mounting 2 5.2 Installation into pipework 2
More informationSTAD-D. Balancing valves Balancing valve for domestic water systems, DN Balancing valves
STAD-D Balancing valves Balancing valve for domestic water systems, DN 15-50 Balancing valves IMI TA / Balancing valves / STAD-D STAD-D The STAD-D balancing valve delivers accurate hydronic performance
More informationType 4708 Supply Pressure Regulator
Type 708 Pressure Regulator Application pressure regulator used to provide pneumatic measuring and control equipment with a constant air supply Set point range 0.5 to bar (8 to 90 psi) The pressure regulator
More informationRemeha Quinta Cascade guide
Technical information Remeha Quinta Cascade guide Cascade guide Cascade systems 2 Remeha Quinta Cascade guide TABLE OF CONTENTS FOREWORD 4 1 GENERAL DESCRIPTION OF CASCADE SYSTEMS 4 1.1 Optimum number
More informationModel Series 62 Constant Differential Relay
Siemens Industry, Inc. INSTALLATION AND SERVICE INSTRUCTION INTRODUCTION Model Series 62 Constant Differential Relay Rev 11 March 2011 Supersedes Rev 10 The Constant Differential Relay maintains a constant
More informationSeries 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28
Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) and balanced Type 2422 Valve Type 42-24 Type 42-28 Application Differential pressure regulators
More informationLRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.
LRS(H)4 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to the
More informationBiodec Decanter. Ideal with our CYCLATOR technology
Biodec Decanter B IODEC decanters are employed in SBR/Cyclic wastewater processes to separate the sludge from clear effluent. After careful research and development, UTB have developed their BIODEC decanter,
More informationSTAD. Balancing valves DN (MD60, MD61, MD62)
STAD Balancing valves DN 15-50 (MD60, MD61, MD62) IMI TA / Balancing valves / STAD STAD The STAD balancing valve delivers accurate hydronic performance in an impressive range of applications. Ideally suited
More informationCAST IRON SAFETY VALVE TYPE 6301
CHARACTERISTICS The 6301 safety valve is dedicated to protect the equipment from potential overpressure. This is an automatic device that closes when the pressure conditions are back to normal. It is a
More informationLiquid level glasses, type LLG REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Liquid level glasses, type LLG 185-1550 REFRIGERATION AND AIR CONDITIONING Technical leaflet Introduction LLG are liquid level glasses in ductile steel which meets the strictest requirements on industrial
More informationRed Valve Coarse and Fine Bubble Air Diffuser Systems
Red Valve Coarse and Fine Bubble Air Diffuser Systems Red Valve: Your Partner in and Manufactu 2 Tideflex diffusers provide optimal aeration, while mixing prevents stratification. Red Valve s patented
More informationVSR modulating valves with membrane actuator
Modulating valves are used in process technology to control process parameters such as temperature, pressure or flow when handling liquid and gaseous media. uth's team of design and process engineers have
More informationTA-Modulator. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve for modulating control
TA-Modulator Combined control & balancing valves for small terminal units Pressure independent balancing and control valve for modulating control IMI TA / Control valves / TA-Modulator TA-Modulator The
More informationFine Pore Aeration Systems Testing Michael K. Stenstrom Professor, Civil and Environmental Engineering Department
Fine Pore Aeration Systems Testing Michael K. Stenstrom Professor, Civil and Environmental Engineering Department Fine Pore Diffusers Fine pore aeration systems are the most energy conserving alternative
More informationUnit 1, Fullerton Road Rotherham S60 1DJ. Tele: Fax:
Unit 1, Fullerton Road Rotherham S60 1DJ Tele: 0845 601 333 6 Fax: 0845 601 333 7 info@fabricatedproducts.co.uk www.fabricatedproducts.co.uk Data Sheet 6.0 Rubber Pump Flexes All rubber bellows are suitable
More informationKörting Liquid Jet Vacuum Ejectors
Körting iquid Jet Vacuum Ejectors Körting iquid Jet Vacuum Ejectors iquid jet vacuum ejectors convey and compress gases or vapours with the aid of a liquid motive fluid. During this action vapours - corresponding
More informationSTA. Double regulating valves DN 15-50
STA Double regulating valves DN -0 IMI TA / Balancing valves / STA STA The STA double regulating valve delivers accurate hydronic performance in an impressive range of applications. Ideally suited for
More informationInstallation and Maintenance Instruction Manual
Installation and Maintenance Instruction Manual Bourdon tube pressure gauge, model T5400, T5500 and T6500 for industrial application In the following configuration: ###T5400### bourdon tube pressure gauge
More informationOld documentation - Only for your information! Product is not available anymore!
Double solenoid valve Regulator and safety combination Infinitely variable floating operation DM-EF 07-7. Printed in Germany Rösler Druck Edition 0.0 Nr. 9 Flanges, pressure switches, line sockets, pulse
More informationS1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators Installation and Maintenance Instructions
PREVIOUS REFERENCE NO. IMP02355 0231150/13 IMF0501ENISS2 CMGT S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators Installation and Maintenance Instructions 1. Safety information 2. General product information
More informationSteam Trap BK BK 212-ASME. Original Installation Instructions English
Steam Trap BK 212.. BK 212-ASME EN English Original Installation Instructions 810609-02 1 Contents Page Important Notes Usage for the intended purpose... 3 Safety note... 3 Danger... 3 Attention... 3 Application
More informationGLAUNACH THE SILENCER HANDBOOK INSTALLATION GLAUNACH GMBH ALL RIGHTS RESERVED -
GLAUNACH THE SILENCER HANDBOOK INSTALLATION GLAUNACH GMBH 2010 - ALL RIGHTS RESERVED - Part VII page 2 of 8 1. CHOOSING THE INSTALLATION LOCATION When selecting a suitable site for the installation of
More informationThe activated sludge process
The activated sludge process Most wastewater treatment plants are using the activated sludge process. The heart of such a process mainly consists of an aeration tank, a sedimentation tank or clarifier
More informationCombined Pressure / Vacuum Relief Valve KITO VD/o
KITO VD/o DN D H kg* vacuum setting (mbar) pressure DIN ANSI DIN ANSI min max min max** 50 PN 16 2 220 332 351 11 3 50 10 75 80 PN 16 3 260 367 387 145 3 50 10 70 100 PN 16 4 260 368 393 178 3 50 10 80
More informationTank Blanketing Pressure Regulators RHPS Series
www.swagelok.com Tank Blanketing Pressure Regulators RHPS Series Types: pressure reducing and vapor recovery 16L stainless steel construction 1/2, 1, and 2 in. end connections Working pressures up to 22
More informationContents. 1. General information BROEN BALLOMAX Steel Ball Valves Approvals Quality Management...2
Contents 1. General information...2 1.1 BROEN BALLOMAX Steel Ball Valves...2 1.2 Approvals...2 1.3 Quality Management...2 2. Preoperational Instructions and Precautions...2 3. Plates...3 4. Transport and
More informationBall Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"
Data Sheet 819584-00 Issue Date: 01/17 Ball Float Steam Trap UNA 43 PN 16/C 125/JIS 10K UNA 46 PN 40/C 150/C 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6" UNA 43 hl, UNA 46 hl UNA 43 v, UNA 46 v with
More information