Mid-size Venturi Vacuum Pump with Interchangeable Cartridges and Silencer
|
|
- Amberlynn Cook
- 6 years ago
- Views:
Transcription
1 id-size Venturi Vacuum Pump with Interchangeable Cartridges and Silencer Ideal Applications: VP20/ VP20BV Standard Pump: VP20 id Series air-powered venturi vacuum pumps are the most commonly used pumps for pick & place applications due to their ease of mounting and the variety of options and accessories available. Vaccon id Series vacuum pumps provide maximum design versatility: designers specify only the features necessary for their specific application. VP20BV offers a 2-way integrated valve. Vaccon s interchangeable venturi cartridge system enhances manufacturing flexibility, enabling designers to choose the vacuum level, vacuum flow, evacuation speed and air consumption based on any one of 11 venturi cartridges. Performance evel Designations: 0-10 g [0 to 339mbar] for low vacuum/high flow applications 0-20 g [0 to 677mbar] for medium vacuum/high flow applications 0-28 g [0 to 948mbar] for high vacuum/standard flow applications VP20-90 pump with SX-5 switch monitors presence of box. No filters required. VP20BV-150 with optional ports for vacuum gauge and sensor/switch Features/Benefits: interchangeable venturi cartridges leakage providing a strong holding force and lighweight up to 28 g [948mbar] vacuum point ~ Straight-through design, non-clogging ~ No moving parts to wear or clog ~ No flap valves to stick open ~ No maintenance ~ No downtime Pump Options: control systems 2-way Integrated valve - 24vdc, normally closed vacuum sensor and troubleshooting for ultra quiet operation with metric threads 80 PSI [5.5 BAR] standard, 60 PSI [4.0 BAR] option) Principles of Operation: Vacuum is produced by forcing compressed air through a limiting orifice (nozzle). As the air exits the orifice, it expands, increasing in velocity to supersonic speed before entering the venturi section (diffuser). This creates a vacuum at the vacuum inlet port, located between the nozzle and diffuser. The nozzle and diffuser combine to create a venturi vacuum cartridge. Air Supply Vacuum Exhaust Vacuum Eliminate the Guesswork: Contact s! Vacuum technology isn t an exact science. To ensure proper product selection, Vaccon offers free application engineering assistance, a 30 Day Test & Evaluation Program or you can send sample products to our in-house test facility and we will test and size a pump for you. To download a complete set of drawings in 13 different CAD formats, please visit our website at For more information or technical assistance, please call or or engineering@vaccon.com 66
2 VP20- (60, 90, 100, 150) (,, ) id Series Configurations and Options: All Vaccon pumps offer a variety of options and accessories to meet your specific requirements. Please configure your pump from the options listed below. VG-150 Supply Port NPT or Threads Valve Assembly Cartridge Assembly (nozzle & diffuser) AA4 Silencer (standard) ST4 Silencer STAA4 Silencer Optional Switches/Sensor w/quick Disconnect VSN-QD-6 6 pigtail & QD VSP-QD-6 6 pigtail & QD VTV-QD-6 6 pigtail & QD Adjustable echanical Switch SX-4 SX-5 ow to Specify: VP20 VP20BV Imperial Thread-NPT No Valve with Valve Assy etric Thread-G Port I-VP20 No Valve I-VP20BV with Valve ax. Flow evel 60 (Not Available in ) VP ST4 - VSP-QD-6 Switch/Sensor None (Standard) VSN-QD-6 Switch NPN with QD VSP-QD-6 Switch PNP with QD VTV-QD-6 Sensor 1-5VDC Output w/qd SX-4 Switch "g SX-5 Switch "g ST4 STAA4 VP20 pumps are Fractional and etric T-Slot compatible. See EOAT Section. Silencer AA4 - Closed End (Standard) Straight-Through ybrid ax. Vac evel 10"g [339mbar] 20"g [677mbar] 28"g [948mbar] Operating Pressure 80 PSI [5.5 Bar] (Std) PSI [4.0 Bar] For complete Performance Data, see page 102. VG-150 Vacuum Gauge Vaccon does not recommend shipping gauges attached to pumps. Please specify as a separate line item. 67
3 Standard Pump: VP20 - (60, 90, 100, 150) (,, ) STAA4 SIENCER Standard VP20-90 with AA4 sliencer SETPOINT ADJ. (VSP, VSN ONY) 'Y' AX. VAC PORT F 'A' AIR SPPY PORT AA4 SIENCER E R 'C' EXAST PORT J K P S N T 3X 'D' ONTING OES 5 AX. VAC PORT ST4 SIENCER Specifications: Standard VP20-90 Weight: 5.1 oz [146g] Noise evel: 64dB V W 'B' VAC PORT Imperial Dimensions (in.) VP20 A B C D E F J K N P R S T V W Y 4.59 w/st w/staa4 1/4 1/4 1/ / w/vsp-qd-6, NPT F NPT F NPT F NPT F VTV-QD-6, 1.49 etric Dimensions (mm) I- VP20 A B C D E F J K N P R S T V W Y w/st w/staa w/vsp-qd-6, VTV-QD
4 Standard Pump: VP20BV - (60, 90, 100, 150) (,, ) Standard VP20BV-90 with AA4 silencer 'A' AIR SPPY PORT STAA4 SIENCER POWER CONNECT EADS 24 AWG (.51mm) BK -24VDC RED +24VDC J SETPOINT ADJSTENT 180 (VSP & VSN ONY) 'Y' AX. VAC PORT 'C' EXAST PORT F AA4 SIENCER E K R P S 3X 'D' ONTING OES N T 5 AX. VAC PORT ST4 SIENCER Specifications: Standard VP20BV-90 Weight: 8.1 oz [229.6g] Noise evel: 64dB W V 'B' VAC PORT Imperial Dimensions (in.) VP20BV A B C D E F J K N P R S T V W Y 7.75 w/ ST w/staa4 1/4 1/4 1/ / w/vsp-qd-6, NPT F NPT F NPT F NPT F VTV-QD-6, 1.49 etric Dimensions (mm) I- VP20BV w/ A B C D E F J K N P R S T V W Y w/st w/staa w/vsp-qd-6, VTV-QD-6,
5 VP20 Pump Standard Specifications: Pump aterial: Anodized Aluminum (For silencer material, see page ) Cartridge aterial: Nylon, Buna-N O-ring (Other materials available, see page 8) edium: Filtered (50 icron) un-lubricated, non-corrosive dry gases Operating Temperature: -30 ~250 F [-34 ~121 C] Operating Pressure: 80 PSI [5.5 BAR] standard or 60 PSI [4.0 BAR] Consult Factory for other operating pressures Optional 2-Way Valve Specifications: Valve Type: Base ounted 2-Way, Solenoid Valve, Normally closed Valve Body aterial: Brass, Aluminum, Buna-N Valve Operating Pressure: Vacuum to 120 psi [-1 to 8 bar] Electrical: 24 VDC [-15% to +10% Nominal] Average ife: 100 million cycles or better Power Consumption: 4 watts Response Time: 6 milliseconds Cycle Rate: 80 cycles/second Electrical Connection: ED Indicator: Yes VP20 Operating and Installation Requirements: Cartridge size: C60 (, ) and C90 (,, ) C100 (,, ) and C150 (,, ) Supply ine: 1/4 O.D. [6mm] tube recommended 3/8 O.D. [10mm] tube recommended Vacuum ine: 1/4 O.D. [6mm] tube recommended 3/8 O.D. [10mm] tube recommended Vacuum ine Filtration: Control Valve: 3 way/2 position (faster part release), minimum orifice ID [3mm] ounting oles: ounting holes accept or 5 screws 70
Modular Venturi Vacuum Pumps Miniature Venturi Vacuum Pump with Silencer Fastvac Mini Series: VP00 VP00-60H picks and places IC chips on circuit board
iniature Venturi Vacuum Pump with Silencer Fastvac ini Series: VP00 VP00-60 picks and places IC chips on circuit boards Standard Pump: The VP00 Fastvac ini Series air-powered venturi vacuum pumps are highly
More informationHighVac Pumps. High Vacuum Venturi Pumps. Modular Venturi Vacuum Pumps with Solenoid-Operated Vacuum and Blow-Off
Modular Venturi Vacuum Pumps with Solenoid-Operated Vacuum and Blow-Off Vaccon offers a High Vacuum Venturi Pump in a variety of performance ranges. Each HighVac Series Pump is capable of 29.5 Hg [999mbar]
More informationCylindrical Venturi Vacuum Pumps Cylindrical Venturi Vacuum Pumps Mid J Series Principles of Operation: JS-200-ST6A used extensively in vent-less mold
ylindrical Venturi Vacuum Pumps Mid J Series Principles of Operation: JS-200-ST6A used extensively in vent-less molding applications i.e. rubber tire mold evacuation Standard Pump: The J-100 and J-150
More informationMiniature Venturi Vacuum Pump with 3-way Integral Solenoid Valve and Silencer
odular Venturi iniature Venturi Vacuum ump with 3-way Integral olenoid Valve and ilencer astvac ini eries: V01-60 V01-60/24vD-2 tandard ump: V01 astvac ini eries pumps are solenoid-controlled miniature
More informationMid Series Venturi Vacuum Pump, Solenoid Operated with Pneumatic Blow-off and Silencer
id eries enturi acuum ump, olenoid Operated with neumatic low-off and ilencer id eries: & -AD -90 loads and unloads water bottle capping operation tandard ump: and -AD air-powered venturi vacuum pumps
More informationSchroeder Check Test Point System
Perforated polyamide / kevlar hose, 2 mm ID, 5 mm OD, plastic dust cap. L in (mm) P (max) psi (bar) 6 (150) 10,000 (680) 12 (300) 10,000 (680) 24 (610) 10,000 (680) 36 (915) 10,000 (680) 48 (1220) 10,000
More informationHand lever valves VHER
Hand lever valves VHER Hand lever valves VHER Key features Powerful Flexible Practical -M- Flow 170 3800 l/min 4/3-way valve mid-position closed mid-position exhausted mid-position pressurised Connections:
More informationZ, Y, and X PURGE INDICATORS / CONTROLLERS
PurgEx XXXXXX Z, Y, and X PURGE INDICATORS / CONTROLLERS PURGE / PRESSURIZATION PURGE / PRESSURIZATION XXXXX XXXXXXXXX 8626 SERIES Globally Certified Z,Y,X Purge Indicators / Controllers and Accessories
More informationRK LEL Sample Draw Aspirator Adapter Operator s Manual
30-0951RK LEL Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0017RK Revision: A Released: 6/2/10 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment
More informationMultiple Connection Manifolds
ultiple onnection anifolds PNUAYN, IN. atalog 2400 Phone 763-559-0177 ax 763-559-0547 eatures l 2 to 10 stations l Inline anifolds, 90 anifolds, ual Air, unction locks and Terminal locks l ustom designs
More informationSeries 10-IRV10/20. Vacuum Regulator C08 IRV C08 IRV 20 A. How to Order. Standard connections. Single sided connections. Accessory w Nil G ZN ZP ZA ZB
Vacuum egulator eries -IV/ How to Order tandard connections IV C08 traight Clean series ody size Max. flow 140 L/min (N) Max. flow 240 L/min (N) L Fittings traight Connection tubing O.D. ymbol ubing O.D.
More informationSECTION 9 CLASSIC SERIES PUMPS
SECTION CLASSIC SERIES PUMPS 07 EDCO USA www.edcousa.net : CLASSIC PUMPS DUAL BASE CLASSIC PUMPS TRIPLE BASE CLASSIC PUMPS QUAD BASE CLASSIC PUMPS General Information : Classic Pumps: How To Order :4 Classic
More informationRK-IR Sample Draw Aspirator Adapter Operator s Manual
30-0951RK-IR Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0018RK Revision: A Released: 6/2/10 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment
More informationThe Ins and Outs of I/P Transducers
The Ins and Outs of I/P Transducers By Mark B. Levine, ControlAir Inc. General description I/P transducers are versatile instruments that use an electrical control signal to proportionally regulate gas
More informationCSA Sample Draw Aspirator Adapter Operator s Manual
30-0951-CSA Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0367 Revision: 0 Released: 4/30/15 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating
More informationNickel-Plated Brass Right Angle Flow Control Valves NPTF/Inch Series GSCU, GMCU, GSVU, GMVU, GSCO, GMCO
Nickel-Plated Brass Right Angle Flow Control Valves NPTF/Inch Series GSCU, GMCU, GSVU, GMVU, GSCO, GMCO Swivel Design : Meter-Out, Meter-In and Needle Orifice Tube Diameter OD: 1/8, 5/2, 1/4, 5/16, /8
More informationALF400 to 900, ALT-5/-9
Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Auto feed lube 00 00-0 00 00 00 900 - --IS- -9 AIR : OIL : Fluid Proof pressure Air. MPa 0. MPa.0 MPa (Note ) Operating pressure differential
More information3D drawings available at
With their extremely reduced size and high performance, these single-stage vacuum generators operate exploiting the Venturi principle. Supplying the generator with compressed air in P, vacuum will be generated
More informationStandard Operating and Maintenance Instructions for Pumping System Model PS-90
Standard Operating and Maintenance Instructions for Pumping System Model PS-90 High Pressure Equipment Company 2955 West 17th Street, Suite 6 PO Box 8248 Erie, PA 16505 USA 814-838-2028 (phone) 814-838-6075
More informationAuto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9
Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Fluid Proof pressure Operating pressure differential range (Difference between tank pressure and line pressure) Vibration resistance
More informationGWB Pneumatic 2-Finger Radial Gripper Universal Gripper Sizes Weight Gripping moment Opening angle per finger Workpiece weight
GWB Sizes 34.. 100 Weight 0.14 kg.. 3.5 kg Gripping moment 2.1 Nm.. 127 Nm Opening angle per finger 10.. 90 Workpiece weight 0.3 kg.. 6.0 kg Application example Rotating/gripping combination for handling
More informationPWG-S. Application example. Pneumatic 2-Finger Angular Gripper Universal Gripper. Sizes. Gripping moment 5.98 Nm Nm. Weight 0.21 kg 1.
PWG-S Sizes 40 80 Weight 0.21 kg 1.2 kg Gripping moment 5.98 Nm 50.82 Nm Angle per jaw 20 Workpiece weight 1.1 kg 4.8 kg Application example Rotating/gripping combination for flexible handling of sheet
More informationPneumatic Hand Pumps with no Gauge Connection (scissor handle) AP0V (300 psi / 20 bar)
Pneumatic Hand Pumps with no Gauge Connection (scissor handle) AP0V (300 psi / 20 bar) The quickest and most economical way to perform pneumatic field pressure calibrations on pressure transmitters, switches
More informationFIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:
LOW PRESSURE FILTERS Max Flow: gpm ( lpm) In-Tank Filters Working Pressures to: Rated Static Burst to: psi kpa bar psi kpa bar Flow Range to: gpm lpm Features STYLE C STYLE D STYLE E in-tank filters are
More informationSIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information
SIX R431006322 (P -063892-00001) AND SEVEN R431006321 (P -063981--00002) POSITION CYLINDERS Service Information The six and seven position cylinders are medium duty pneumatic positioning devices that operate
More informationProportional pressure regulators VPPE
Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/
More informationINSTALLATION & MAINTENANCE INSTRUCTIONS
DESCRIPTION / IDENTIFICATION The QBX series valve uses Proportion-Air closed loop technology for Pressure control. It gives an output pressure proportional to an electrical command signal input. The QB1X
More informationPrecision Regulator. Series Model Regulating pressure range Port size Page
Precision Regulator Series // Basic Type Air Operated Type Series Model Regulating pressure range Page Series Series Series Series Series.5 to MPa. to MPa. to.8 MPa /8 55.5 to MPa. to MPa /4 55. to.8 MPa.
More informationSPG. Application example. Pneumatic 2-Finger Parallel Gripper Heavy-load Gripper. Weight 35 kg. Stroke per finger 100 mm.
SPG Size 100 Weight 35 kg 10,000 N Stroke per finger 100 mm Workpiece weight 50 kg Application example Gripper unit for heavy V8 engine blocks. SPG 100 2-Finger Heavy-load Gripper 446 www.schunk.com SPG
More informationSECTION 12 VACUUM GRIPPERS
SECTION VACUUM GRIPPERS 07 EDCO USA www.edcousa.net : VG8 VG8 DVG General Information : - :4 Selection Guide :4 - :5 VG8 :6 VG8 :7 VG Options :8 VG Mounts :9 DVG : Dual Vacuum Grippers : DVG Options :-
More informationType Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN
Type 4708-45 Pressure Regulator for increased air capacity Fig. 1: Type 4708-45 Pressure Regulator Mounting and Operating Instructions EB 8546-1 EN Edition March 2010 Definition of the signal words used
More informationMULTI-STAGE VACUUM GENERATORS PVP 12 MX and 25 MX
MULTI-STAGE VACUUM GENERATORS PVP 12 MX and 25 MX This new range of multiple ejector vacuum generators represents the natural evolution of the PVP 12M and 25M generators. In fact, given the same air consumption
More informationINSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant
INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION The QB3 is a closed loop pressure regulator consisting of two solenoid valves, internal pressure transducer, and electronic controls mounted to an integrated
More informationDesign Features. General Description
Model thermal Mass Flow Controllers are designed to indicate and control set flow rates of gases. The combines the characteristics and accuracy of conventional mass flow devices into a unique compact design
More informationSECTION 11 VACUUM GRIPPER
VACUUM GRIPPERS SECTION VACUUM GRIPPER EDCO USA. www.edcousa.net : CONTENTS GENERAL INFORMATION ER L-Series Coaxial Venturi Technology : Centralized Systems : Operating Pressure : Discrete Systems :4 Rugged
More informationTribomatic II Powder Pump
Instruction Sheet P/N Tribomatic II Powder Pump WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation.
More informationNorth American Orifice Metering System
Combustion North American Orifice Metering System 8697 and M8697 Metering Orifices accurately measure gas flows to industrial burners. They are compact, inexpensive, and can be installed in individual
More informationDescription Advanced Features Typical Applications
Series single stage, brass barstock line regulator Description Advanced Features Typical Applications The Series regulators are intended for secondary pressure control of noncorrosive, high purity or liquefied
More informationSeries SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100
Clean Air Filter Variations SFD SFD SFD SFD Made to Order Type Disposable (non-replaceable element) Cartridge (replaceable element) Flow rate L/min (ANR) (at inlet pressure.7 MPa) Up to 6 Up to 8 Up to
More informationTest pumps. Pressure sources. Good reasons for proper and reliable calibration
Test pumps Pressure is one of the most commonly measured quantities in engineering, which is why exact and reliable pressure measurement is especially important. However, the characteristics of the even
More informationRCD - Ultra-Rugged Differential Pressure Flowmeter
0.15-1 to 85-600 GPM Liquids 2.5-25 to 300-1700 SCFM Gases 1/2 to 3 Line Sizes Bronze or 316-Ti Stainless Steel Mechanical Indicator, Digital Indicator, Transmitters and Switches Available Custom Calibrations
More information1200 Series Pressure Regulators
SEE MORE AT SORInc.com Request Quote 1200 Series Pressure SOR pressure regulators are durable, high performing instruments that are designed to provide reliable control of pressure in various stages of
More informationFITTINGS THREAD LUBRICANTS. Fittings 20,000 PSI
Jetstream offers a wide variety of fittings with various connection types to fit your 20,000 psi application needs. The standard connection types, Type M, MP, and MP Tube lance, are available in standard
More informationVACUUM REGULATORS CONTENTS
CAD drawing data catalog is available. ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Small Regulators Features 759 Specifications, Order Codes, Flow Rate
More informationSeries IRV1000/2000/3000
CAT.ES60-16 A Regulator Series /2000/3000 Allows adjustment of vacuum line pressure Regulator Series /2000/3000 3 sizes offered in the series Variations have been expanded to three sizes from only one
More informationPressure decay sensor Pressure decay sensor Flow at 90 psi (6 bars) Tripping point at 90 psi (6 bar) supply Connection Mechanical life Relay C
Position Detectors Order/Technical Support Tel: (800) 6773 / FAX: (800) 677386 / www.crouzetusa.com / Pressure decay sensor Pressure decay sensor 8 04 02 Flow at 90 psi (6 bars) Tripping point at 90 psi
More informationPSH. Application example. Pneumatic 2-Finger Parallel Gripper Long-stroke Gripper. Stroke per finger 14 mm.. 64 mm. Sizes
PSH Sizes 22.. 52 Weight 0.77 kg.. 8.05 kg 320 N.. 1760 N Stroke per finger 14 mm.. 64 mm Workpiece weight 1.60 kg.. 8.80 kg Application example Rapid loading and unloading unit on a swivel head base.
More informationElectropneumatic Transducer (I/P) Installation, Operation and
Nitra NCP1 Series Electropneumatic Transducer (I/P) Installation, Operation and Maintenance Instructions Ordering Information Contents Part Number I/P Transducers Output Range Input psig bar Section Description
More information30% (SMC comparison) Silencer. New. New. The M5 silencer is now added! The resin silencer is now a more compact size! Series AN.
Silencer The M silencer is now added! Space saving New RoHS ctual size 6. mm mm Fingertip size The resin silencer is now a more compact size! Existing model Entire length reduced by up to 30% (SMC comparison)
More informationcompact ejector, Series ECM with Adjustable release pulse with silencer With filter vacuum switch: electronic 2 x PNP
00134428 Type Miniature compact injector Ambient temperature min./max. +0 C / +0 C Medium temperature min./max. +0 C / +0 C Working pressure min./max. 2. bar / 6 bar Medium Compressed air Max. particle
More informationPSH (inch version) Application example. Pneumatic 2-Finger Parallel Grippers Long-stroke Grippers. Stroke per finger 14 mm.. 64 mm. Sizes 22..
PSH (inch version) Sizes 22.. 52 Weight 0.77 kg.. 8.05 kg Gripping force 320 N.. 1760 N Stroke per finger 14 mm.. 64 mm Workpiece weight 1.60 kg.. 8.80 kg Application example Rapid loading and unloading
More informationIR1000-A IR1010-A IR1020-A
Document No. IR -OMT0020 PRODUCT NAME Precision Regulator MODEL / Series / Product Number IR1000-A IR1010-A IR1020-A Contents Safety Instructions 1 to 5 1. Application 6 2. Specifications 6 3. Construction
More informationDPZ-plus. Application example. Pneumatic 3-Finger Centric Grippers Sealed Grippers. Gripping force 520 N N. Sizes
DPZ-plus Sizes 64.. 200 Weight 0.62 kg.. 20.1 kg Gripping force 520 N.. 16800 N Stroke per finger 3 mm.. 25 mm Workpiece weight 2.6 kg.. 60.0 kg Application example Insertion tool for assembling small
More informationBuying more than 11 gauges? Call Lesman for additional discounts.
Low Cost Liquid Filled Pressure Gauges Size: 1.5", 2", and 2.5" Accuracy: 2.5% of full scale Materials: Case and ring: 304 stainless steel; Window: Polycarbonate; Seals: Buna-N; Pointer: Black-finished
More informationChoosing the right miniature instrument and control valve is a snap
Choosing the right miniature instrument and control valve is a snap INVALCO Micro Valve The Micro Valve is a unique miniature valve offering versatility and rugged construction. Since its introduction
More informationGREIG FILTERS, INC. OPERATION MANUAL
GREIG FILTERS, INC. OPERATION MANUAL MODEL DCFH 3P 15/3 100 S4 DOE/222 DUAL CARTRIDGE FILTER HOUSING TABLE OF CONTENTS I. INTRODUCTION II. CARTRIDGE FILTER HOUSING UNIT A. OPERATION B. INSTALLATION C.
More informationPTFE-SINGLE GLASS FLOW METERS
PTFE-SINGLE GLASS FLOW METERS T GENERAL DESCRIPTION Model T fl ow meters incorporate the principles of traditional variable area fl ow technology. PTFE 150mm with MVT TM Valve These rugged PTFE-Glass flow
More informationPFH. Application example. Pneumatic 2-Finger Parallel Gripper Long-stroke Gripper. Weight 2.65 kg 12.6 kg. Gripping force 630 N 2950 N
PFH www.comoso.com Sizes 30 50 Weight 2.65 kg 12.6 kg Gripping force 630 N 2950 N Stroke per finger 30 mm 100 mm Workpiece weight 3.15 kg 13 kg Application example Assembly unit for intermediate sleeves
More informationG1/8 G1/8. Model 0 bar -0,1 bar -0,2 bar -0,3 bar -0,4 bar -0,5 bar -0,6 bar -0,7 bar -0,8 bar
single stage pumps M/5811 Very high induced air capacity % lower air consumption than comparable single stage units No wearing parts Compatible with a wide range of line contaminants llows direct connection
More informationComponents for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.
Components preparation and pressure adjustment ABP Overview ABP is a component that enables boosting by s only up to twice primary pressure (.0MPa max.) in combination with using air tank but not using
More informationModel 4000 Pressure Controller
FEATURES Multiple Configurations The 4000 series pressure controller can be configured into either proportional only or proportional plus reset mode with a minimum of parts. Rugged Design Die cast aluminum
More informationDPC-30 DPC-100. Reference Manual
DPC-30 DPC-100 Reference Manual 1. Introduction 1.1 Description The Martel DPC Digital Pneumatic Calibrator improves upon traditional dial gauge pneumatic calibrators. The Martel DPC improves accuracy,
More informationPrecision Pressure Regulators. Precision Fluidics
Precision Pressure Regulators Precision Fluidics This is increased efficiency. Precision low flow carrier gas control for gas chromatography. Parker precision regulators, valves and controllers are designed
More informationWARNING. Work drop prevention check valves FPV series. Vacuum accessories. Safety handling of workpiece with several pads
Work drop prevention check valves series Safety handling of workpiece with several pads Enable using one CONVUM ejector and several pads, in applications where some of the suction pads may not be in contact
More informationPrecision and Instrument Regulators 1/4" port size
Section 8 Precision and Instrument Regulators /" port size Contents -8 Precision Air Pressure Regulator /" ports............ale-8-2 R38 Instrument Regulator Aluminum Model /" ports.........ale-8- -8 R38
More informationVacuum Regulator. IRV10/20 Series. Weight reduced by. RoHS ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV
Vacuum egulator IV0/ eries oh AJ A45 ingle ided Connections eries AX For ease of installation and panel mounting AM AM Integrated digital pressure switch for panel mounting I -A I (Made to Order) ingle
More informationSWG. Application example. Pneumatic 2-Finger Angular Gripper Angular Gripper for Small Components. Sizes Gripping moment 0.01 Nm.. 2.
SWG Sizes 10.. 50 Weight 2.5 g.. 213 g Gripping moment 0.01 Nm.. 2.8 Nm Opening angle per finger 15 Workpiece weight 0.007 kg.. 0.45 kg Application example Triple transfer unit for packaging with small
More informationModel 10. Low-Medium Pressure Reducing Regulator
Model 10 Low-Medium Pressure Reducing Regulator General Specifications & Performance Characteristics The Model 10 is a pressure reducing regulator useful in a wide variety of applications. The Model 10
More informationAir Operated Hydraulic Pumping Systems to 50,000 psi
High Pressure Equipment Air Operated Hydraulic Pumping Systems to 50,000 psi PS-10: 10,000 psi PS-20: 20,000 psi PS-30: 30,000 psi PS-40: 40,000 psi PS-50: 50,000 psi PS-90: 90,000 psi High Pressure air
More informationSPECIFICATIONS ATTENTION
VPS 504 S06 Installation Manual - P/N 80122 - Ed. 01/09 VPS 504 S06 and S05 Valve Proving System Installation Instructions VPS 1 6 Gases Natural gas, air and other inert gases. NOT suitable for butane
More informationPRO-50 Instrument Supply Regulator
Features CRN Approved The PRO-50 Regulator has been granted a Canadian Registration Number. Sour Service Capability Available in NACE configurations that comply with NACE MR0175/MR0103. Environmental limits
More information2-JAW SELF-CENTERING PARALLEL PNEUMATIC GRIPPER (SERIES HS)
HS 2-JAW SELF-CENTERING PARALLEL PNEUMATIC GRIPPER (SERIES HS) Designed for high-speed machines. Very short closing/opening times. Lightweight. Maintenance-free long life and reliability. Long stroke.
More informationKEG PUMP. Range of Electric Keg Pumps
KP KEG PUMP Range of Electric Keg Pumps Electric Keg (Drum) Pumps for Grease KEG PUMP Versatile range of Interlube electric grease pumps for industrial and off-road applications The KP keg pump is available
More informationPZN-plus. Application example. Pneumatic 3-Finger Centric Gripper Universal Gripper. Sizes Gripping force 580 N..
PZN-plus Sizes 40.. 300 Weight 0.43 kg.. 43.5 kg Gripping force 580 N.. 38000 N Stroke per finger 3 mm.. 35 mm Workpiece weight 2.9 kg.. 190 kg Application example Insertion tool for assembling small to
More informationPFH. Application example. Pneumatic 2-Finger Parallel Grippers Long-stroke Grippers. Sizes Gripping force 510 N N
PFH Sizes 30.. 50 Weight 2.65 kg.. 9.7 kg Gripping force 510 N.. 2650 N Stroke per finger 30 mm.. 50 mm Workpiece weight 2.55 kg.. 11.5 kg Application example Assembly unit for intermediate sleeves in
More informationQBS Electronic Pressure Regulator
INSTALLATION AND MAINTENANCE INSTRUCTIONS DESCRIPTION / IDENTIFICATION The QBS stainless steel series is an electronically controlled pressure regulator. The QBS controls the pressure on its output port
More informationPneumatic Grippers Swivel Modules
Pneumatic Grippers Swivel Modules Pneumatic Grippers Swivel Modules ROTARY GRIPPERS MODULES Series Size Page GSM 748 Parallel Grippers GSM-P 750 GSM-P 32 754 GSM-P 40 760 GSM-P 50 766 GSM-P 64 772 Centric
More informationGripping rotary modules
Gripping rotary modules Gripping rotary modules GRIPPING ROTARY MODULES Series Size Page Gripping rotary modules RP 314 RP 1212 318 RP 1216 322 RP 1520 326 RP 2120 330 RP 2128 334 RC 338 RC 1212 342 RC
More informationModel 40H Nullmatic Pressure Regulators
Siemens Industry, Inc. INSTALLATION AND SERVICE INSTRUCTION SD40H Rev 10 June 2012 Supersedes Rev 9 Model 40H Nullmatic Pressure Regulators INTRODUCTION The Model 40 Nullmatic Pressure Regulator, shown
More informationSeries 1, 3 and 4 Cv = /8" and 1/4" Ported Manually Operated Valves. 3-way/2-position, 5-way/2-position, 5-way/3position
Cv =.52 -.73 Series, 3 and 4 Cv =.52.3 /8" and /4" Ported Manually Operated Valves 3-way/2-position, 5-way/2-position and 5-way/3-position Ports /8 and /4" NPTF The Series (/8 & /4", 3-way/2-position and
More informationABRASIVE SYSTEM ABRASIVE REGULATOR II 800# BULK ABRASIVE DELIVERY POT Abrasive Regulator II and 800# Pot Manual
ABRASIVE SYSTEM ABRASIVE REGULATOR II 800# BULK ABRASIVE DELIVERY POT TABLE OF CONTENTS Contact Information and Customer & Technical Service... 1 1 Introduction... 1 2 Abrasive Regulator... 1 Description:...
More informationC-Series. Pirate Brand. Product Line Brochure 0.5 / 1.0 CU FT - ABRASIVE BLASTERS. Proudly Distributed By: Rev. May 16
Pirate Brand C-Series 0.5 / 1.0 CU FT - ABRASIVE BLASTERS Proudly Distributed By: See limited warranty documentation for complete details. Product Line Brochure Rev. May 16 Professional Grade Components
More informationSKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function
SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function Technical Instructions Document No. 155-752 SKP25 U.. Description Only when assembled to Series VG Gas valves SKP25
More informationModel 1800 PFM Series Regulator. Technical Bulletin
Model 0 PFM Series Regulator Technical Bulletin Model 0 PFM Series Regulator 0 Elster American Meter The 0 PFM Series regulators are designed to control natural gas, air, nitrogen, carbon dioxide, propane
More informationLiquid Level Controllers
Liquid Level Controllers ALL PUMPS LLC-2Y For both pump up and down control. Variable On/Off set points. NDP-15/20/25/32, DP-10/15 & *NDP-40/50/80 LLC-1 Pump up and down versions available. 6 to 12 differential
More informationPrecision Regulator. IR1000/2000/3000 Series ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV IC ITVH ITVX PVQ VY1 AP100.
Precision Regulator //3 Series Basic Type Air Operated Type Series Model Set pressure range Port size Page Series Series 3 Series 3 3 3 Series 3 Series 3.5 to MPa. to MPa. to.8 MPa /8 8.5 to MPa. to MPa.
More informationWaterSource Heat Pump Hose Kit Performance Specification-Summary
WaterSource Heat Pump Hose Kit Performance Specification-Summary AUTOMATIC & MANUAL BALANCING HOSE KITS Contractor shall provide and install Hays Hose Kits. Each kit, shall include a Hays 2500 Series Mesurflo
More informationTECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY ELECTRIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.
Page 1 of 8 1. DESCRIPTION A Viking Pilot Pressure Regulated Deluge System utilizes a Viking flow control valve to control water flow into the deluge system. The flow control valve must be installed with
More informationNickel-Plated Brass Right Angle Flow Control Valves NPTF/Inch Series GSCU, GMCU, GSVU, GMVU, GSCO, GMCO
Flow Control Valves NORTH MERICN FITTINGS & FLOW CONTROL VLVE CTLOG > Release 8.6 Nickel-Plated Brass Right ngle Flow Control Valves /Inch Series GSCU, GMCU, GSVU, GMVU, GSCO, GMCO Swivel esign : Meter-Out,
More informationALF400 to 900, ALT-5/-9
uto Feed Lube, uto Feed Tank LF00 to 900, -/-9 Standard Specifications uto feed lube uto feed tank LF00 LF00-0 LF00 LF00 LF00 LF900 - --IS- -9 IR : OIL : Fluid Proof pressure ir. MPa 0. MPa.0 MPa (Note
More informationMULTI-STAGE VACUUM GENERATORS PVP M
MULTI-STAGE VACUUM GENERATORS PVP 40 300 M This new range of multi-stage vacuum generators have been designed to be assembled onto OCTOPUS vacuum systems and represents a true evolution of traditional
More informationGas Pressure Switch for DMV safety shutoff valves
Gas Switch for DMV safety shutoff valves GAO-A GMH-A GML-A UL Listed UL 353 File # MH 1668 CSA Certified CSA C. No. LR 53 File # 0157 FM Approved Class 3510, 3530 File # J.I. 1Y9A9.AF Commonwealth of Massachusetts
More informationPilot Check Valve: Metal Body Type
INFORMATION Pilot Check Valve: Metal Body Type The use of a metal body improves strength and environmental resistance. Temporary intermediate stops are possible. *1 *1 Precise intermediate stops are not
More informationCombination Air Valve Model
Combination Air Valve Model Model C10 /C11 Installation, Operation and Maintenance Manual (IOM) Table of Contents General...Page 2 Safety...Page 2 Operational Data...Page 3 Materials and Connections...Page
More informationPneumatic Gripping Modules. Pneumatic 2-Finger Radial Grippers
Pneumatic Gripping Modules Pneumatic 2-Finger Radial Grippers Pneumatic Gripping Modules Pneumatic 2-Finger Radial Grippers 2-FINGER RADIAL GRIPPERS Series Size Page Universal Grippers GWB 676 GWB 34 680
More informationBS2000 MOTOR ELECTRONICS, INC. PROTECTION INSTRUCTION MANUAL. (407) Phone: Website:
BS2000 INSTRUCTION MANUAL MOTOR PROTECTION ELECTRONICS, INC. 2464 Vulcan Road Apopka, Florida 32703 Phone: Website: (407) 299-3825 www.mpelectronics.com Revision Date: 6-23-14 RECOMMENDED REPLACEMENT
More informationAnderson Greenwood Series 93 Positive Pressure POSRV Installation and Maintenance Instructions
Before installation these instructions must be fully read and understood Installation and maintenance instructions for Series 93 Positive Pressure Pilot Operated Safety Relief Valves (POSRV). The intent
More informationPVQ 13 A2 R SE 1 S 20 C-11 D
PVQ - Variable Displacement Piston Pump PVQ 13 A2 R SE 1 S 2 C-11 D 1 2 3 4 6 7 8 9 1 1 Model Series PVQ Inline Piston Pump Variable Volume Quiet Series 4 Rotation Viewed from shaft end R Right hand, standard
More informationThe Cyclone Tire Deflation & Inflation Tool
The Cyclone Tire Deflation & Inflation Tool How it works; This tool operates on compressed air that activates our patent pending venturi that creates a ultra-high vacuum, that draws the air from inside
More information