HYDROVEX TTT Membrane Flow Regulator
|
|
- Eustace Watts
- 6 years ago
- Views:
Transcription
1 HYDROVEX TTT Membrane Flow Regulator INSTALLATION, OPERATION AND MAINTENANCE MANUAL
2 PROJECT EQUIPMENT LOCATION EQUIPMENT DESCRIPTION HYDROVEX TTT REFERENCE N OF THE SUPPLIER MODEL N SERIAL N DATE OF FABRICATION DATE OF DELIVERY SUPPLIER INFO Veolia Water Technologies Canada, Inc Sartelon Montreal, Quebec H4S 2B3 Tel.:(514) Fax:(514) cso@veolia.com ISO 9001:2008 CLIENT INFO CONSULTING ENGINEERING Page 2 of 10
3 WARRANTY All HYDROVEX equipment manufactured by VEOLIA WATER TECHNOLOGIES CANADA INC. is guaranteed to be free from defects in material and workmanship for a period of one (1) year from the date of installation, maximum 18 months from date of shipment. All equipment found with defects during this period will be replaced at no extra charge when shipped prepaid FOB to the manufacturer s shop. All parts sold by VEOLIA WATER TECHNOLOGIES CANADA INC. are warranted the same way for a period of twelve (12) months from date of shipment. If the customer promptly notifies VEOLIA WATER TECHNOLOGIES CANADA INC. in writing of a claimed defect in the equipment and said equipment is found not to be in conformity with this warranty, VEOLIA WATER TECHNOLOGIES CANADA INC. will, at its option and expenses, repair or replace such defective part, prepaid FOB to the manufacturer s shop. VEOLIA WATER TECHNOLOGIES CANADA INC. must be given notice of such defect, and, where requested, such material must be returned to the manufacturer s shop, transportation charges prepaid, with written approval for the shipment by VEOLIA WATER TECHNOLOGIES CANADA INC. This warranty shall be void if start-up of equipment is not authorized by VEOLIA WATER TECHNOLOGIES CANADA INC, or if repairs and/or alterations are made without a written authorization by VEOLIA WATER TECHNOLOGIES CANADA INC. If the equipment or parts supplied by VEOLIA WATER TECHNOLOGIES CANADA INC. are altered in any way without VEOLIA WATER TECHNOLOGIES CANADA INC. consent, the present warranty will not be valid and have no effect. The customer will use only VEOLIA WATER TECHNOLOGIES CANADA INC. parts for all labor covered by this warranty. The foregoing warranty excludes responsibility or liability for: (a) (b) (c) (d) (e) Failures not reported promptly within the warranty period, above specified. Damage due to accident, abuse, shipment, improper installation or operation, or abnormal operation condition. Damage caused by client s replacement, repair or inspection of parts. Lesion or personal accidents, material damage or any direct or indirect expenses or loss of profit related to this warranty. Damage, loss, expenses, lesion or personal accidents directly or indirectly related to the installation, the operation or the failure of the equipment supplied by VEOLIA WATER TECHNOLOGIES CANADA INC. The foregoing warranty is exclusive and replaces all other warranties, expressed or implied, including but not limited to any warranty of bargaining or modification for a particular purpose. This warranty does not cover the following: (a) (b) (c) (d) (e) Costs of repair, modification or other work done or requested by the customer or the management and all indirect costs. All expenses related to regular maintenance of parts as prescribed in the operation and maintenance manuals supplied by VEOLIA WATER TECHNOLOGIES CANADA INC. Costs of dismantling, installation, transportation and insurance. Travelling and living expenses for the personnel carrying out the repair under such warranty. This warranty is not a performance or production warranty. VEOLIA WATER TECHNOLOGIES CANADA INC. has the right to examine or to ask for details about defects before empowering the present warranty. Page 3 of 10
4 TABLE OF CONTENTS Page 1.0 GENERAL INFORMATION APPROVED SHOP DRAWINGS AND DISCHARGE RATING INSTALLATION PROCEDURES 3.1 INSTALLATION IN DRY PIT INSTALLATION IN WET PIT OPERATION MAINTENANCE 5.1 INSPECTION CLEANING METHODS Page 4 of 10
5 Section 1.0 GENERAL INFORMATION The HYDROVEX TTT is a static device that controls discharge flows without the aid of any moving parts or external energy. The control is accomplished as a result of the unit s geometric shape and depends solely on the upstream water pressure head. The HYDROVEX TTT can only work effectively if the installation is properly carried out. Therefore, we recommend that the installation procedure be followed carefully and that: The contractor or subcontractor is familiar with the simple installation procedures of the HYDROVEX TTT. The various elevations, as shown on the drawings, have been verified and respected. That the access hatch to the regulator chamber has a sufficiently large opening for allowing the passage of the HYDROVEX TTT. That you possess all the necessary components of the HYDROVEX TTT required for installation. If you have any problems and or questions concerning the installation procedure, DO NOT HESITATE to contact Customer Service at: Veolia Water Technologies Canada Inc Sartelon Montreal, Quebec, H4S 2B3 Tel.: (514) Fax: (514) cso@veolia.com ISO 9001:2008 Page 5 of 10
6 Section 2.0 APPROVED SHOP DRAWINGS AND DISCHARGE RATING CURVES The drawings and discharge rating curves included hereafter have been approved by the consultant. This information is then used to fabricate the equipment and to evaluate the performance of the equipment. Page 6 of 10
7 Section 3.0 INSTALLATION INFORMATION The model number is an important factor for the installation. For example, 150 TTT-U indicates the inlet diameter of the HYDROVEX TTT, 150 meaning that the unit has a 150- mm nominal diameter. However, all the nominal metric dimensions are converted in standard North American piping. Here are the pipe diameters for the various TTT units: 3.1 INSTALLATION IN DRY PIT Model Diameter 100 TTT (U)(I) 4 inches 150 TTT (U)(I) 6 inches 200 TTT (U)(I) 8 inches 250 TTT (U)(I) 10 inches The chamber that will receive the HYDROVEX TTT should be cleared and properly cleaned prior to installation. Verify if the wall thimble or knife gate is of the proper size. Step No. 1: Lower all of the equipment in the chamber. We assume that the wall thimble and the knife gate valve have already been installed at the right elevation. Step No. 2: Support the HYDROVEX TTT close to the installation centerline of the out coming pipe to make all the relevant adjustments. NOTE: The wall thimble has to be horizontally installed and the knife gate has to be vertically installed. Step No. 3: Align the HYDROVEX TTT with the piping and verify the unit alignment. Step No.4: Tighten all flange bolting, and fix all necessary anchors. Step No. 5: Open fully the knife gate valve and be sure that the by-pass is completely closed. After this installation, the equipment is ready for operation. The unit is always shipped with an extra membrane. Please make sure that this membrane is stored in a dry area and away from direct sunlight, with correct identification at the owner's convenience. This membrane might come handy for maintenance purposes. Page 7 of 10
8 3.2 INSTALLATION IN WET PIT The chamber that will receive the HYDROVEX TTT should be cleared and properly cleaned prior to installation. Verify if the wall thimble is of the proper size. Refer to drawings. Step No. 1: Lower all of the equipment in the chamber. We assume that the wall thimble has already been installed at the right elevation. Step No. 2: Support the HYDROVEX TTT close to the installation centerline of the out coming pipe to make all the relevant adjustments. NOTE: The wall thimble has to be horizontally installed. Step No. 3: Align the HYDROVEX TTT with the piping and verify the unit alignment. Step No.4: Tighten all flange bolting, and fix all necessary anchors. After this installation, the equipment is ready for operation. The unit is always shipped with an extra membrane. Please make sure that this membrane is stored in a dry area and away from direct sunlight, with correct identification at the owner's convenience. This membrane might come handy for maintenance purposes. Page 8 of 10
9 Section 4 OPERATION The operation of the HYDROVEX TTT is based on the Bernoulli principle that is the local depression caused by the velocity of a fluid. The principle can be applied by depressing the pre-stressed membrane trough orifices in the supporting pipe. The pipe has two oval orifices on the side and is installed on the discharge pipe of the reservoir. When the water level increases in the tank upstream tank above the HYDROVEX TTT, the water pressure increases on the outside of the stretched membrane, while the pressure inside the stretched membrane remains at the atmosphere. This pressure difference is further increased by the effect of the water velocity inside the membrane (Bernoulli effect), forcing the membrane to close against the ovals. The reaction of the membrane to the pressure makes the velocity inside the pipe increase, resulting in a decrease in pressure inside the pipe. The combination of those effects creates a strongly regulated discharge at the outlet, with a flow that remains almost constant after the membrane is actuated by the pressure. Page 9 of 10
10 Section 5.0 MAINTENANCE 5.1 INSPECTION The HYDROVEX TTT does not contain any moving parts and requires little maintenance. A visual inspection must be regularly performed on the HYDROVEX TTT at the inlet as well as the outlet of the chamber. This inspection has the purpose of insuring that flow is normal and nothing is blocking the path. Verification of the membrane is required to make sure that there is no sign of wear or that the membrane is pierced. If the membrane is pierced, the flow control will be erratic and replacement of the membrane must be made. 5.2 CLEANING METHODS Step No. 1: Close the knife gate at the inlet of the HYDROVEX TTT and open the knife gate on the bypass of the regulator. Let the network drain itself. If the knife gate cannot be closed because of blockage, empty the upstream by the opening the by-pass or by pumping if the by-pass is also blocked. Never work on a flow regulator without making sure that there is no upstream pressure. If there is no by-pass, pump the upstream chamber for the cleaning period. If the equipment is under pressure for some time, watch for the release of toxic gas when the knife gates are actuated. In doubt, please use a pump to empty the upstream water. Step No. 2: Verify if the obstruction occurred inside the regulating chamber. If this is the case remove the obstacle to clear the path. If not, clean the inside of the regulator with care so as to not damage the membrane, then open the knife gate at the inlet of the regulator and close the knife gate on the by-pass. Page 10 of 10
CSO/STORMWATER MANAGEMENT. HYDROVEX VHV / SVHV Vertical Vortex Flow Regulator
CSO/STORMWATER MANAGEMENT HYDROVEX VHV / SVHV Vertical Vortex Flow Regulator HYDROVEX VHV / SVHV VERTICAL VORTEX FLOW REGULATOR APPLICATIONS One of the major problems of urban wet weather flow management
More informationCSO/STORMWATER MANAGEMENT. HYDROVEX HHV-E Vortex Driven Regulator
CSO/STORMWATER MANAGEMENT HYDROVEX HHV-E Vortex Driven Regulator HYDROVEX HHV-E VORTEX DRIVEN REGULATOR APPLICATION The hydro electronic HYDROVEX HHV driven regulator, type E is specially designed for
More informationModel C Pipe Line Strainer 6, 8 & 10 Inch (DN150, DN200 & DN250) 250 psi (17,2) General Description. Technical Data. Page of 6 MAY, 2006 TFP1644
Technical Services: Tel: (00) 31-9312 / Fax: (00) 791-5500 Model C Pipe Line Strainer 6, & 10 Inch (150, & 250) 250 psi (17,2) General Description The welded steel body Model C Pipe Line Strainers (Ref.
More informationWATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity
WATER HEATER THERMAL EXPANSION TANKS Owner s Manual Safety Instructions Installation Maintenance Warranty Models: 2-5 Gallon Capacity Thank You for purchasing this Thermal Expansion Tank. Properly installed
More informationBS Series Basket Strainer
BS Series Basket Strainer Operating, Installation, & Maintenance Manual Corrosion Resistant Fluid and Air Handling Systems. Dated 04-26-12 PRESSURE DROP SIMTECH strainers are engineered to offer the lowest
More informationINSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures
INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures MINT-0289-XX TABLE OF CONTENTS Limited Warranty... 3 User Responsibility... 3-4 General Service... 4 Safety Precautions.... 5 Physical Dimensions..
More informationModel B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data
Technical Services: Tel: (800) 381-312 / Fax: (800) 71-5500 Customer Service/Sales: Tel: (215) 362-0700 / (800) 523-6512 Fax: (215) 362-5385 Model B-1 Pipe Line Strainer 3,, 6 & 8 Inch (DN80, DN100, DN150
More informationTITAN FLOW CONTROL, INC.
PREFACE: This manual contains information concerning the installation, operation, and maintenance of Titan Flow Control (Titan FCI) Simplex Basket Strainers. To ensure efficient and safe operation of Titan
More informationBLADDER TANK PROPORTIONING SYSTEM PRE-PIPED
BLADDER TANK PROPORTIONING SYSTEM PRE-PIPED HD FIRE PROTECT TECHNICAL DATA TANK MOUNTING Vertical or Horizontal TYPE COENTRATE For Vertical Tank 140 liters STORAGE CAPACITY to7500 liters (36 TO 2000 Gallon
More informationtrigger trigger guard
Made in Germany www.umarexusa.com gas vent hammer cylinder ejector rod cylinder release grip Smith & Wesson Chiefs Special S Cal. 9 mm R.K. (Blank Firing) OPERATING INSTRUCTIONS trigger trigger guard USA
More informationAcid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company
Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company Installation and Operating Instructions DANGER: DO NOT MIX CHEMICALS! The Acid-Rite ph Adjustment System is designed for use with Axiall
More informationCF-SERIES HIGH FLOW REGULATORS
CF-SERIES HIGH FLOW REGULATORS Owner s Manual Printed in U.S.A February 2014 Publication No. OM-CA-3 REV.4 1.3 Copyright Notice 1.0 Introduction The CF-Series are high flow regulators for critical applications
More informationFLANGED TWO-PIECE BALL VALVES
INTRODUCTION This instruction manual includes installation, operation, and maintenance information for FNW flanged split-body ball valves. This manual addresses lever operated ball valves only. Please
More informationSDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual
SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual 8 Executive Drive P.O. Box 2105 Toms River, NJ 08754 (732) 244-0010 (800) 337-3762 fax (732) 244-8140 www.permapure.com info@permapure.com
More informationFLANGED TWO-PIECE BALL VALVES
INTRODUCTION This instruction manual includes installation, operation, and maintenance information for FNW flanged split-body ball valves. This manual addresses lever operated ball valves only. Please
More information4-in-1 Professional Inflator Kit
4-in-1 Professional Inflator Kit Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety
More informationFLANGED MULTI-PORT BALL VALVES
INTRODUCTION This instruction manual includes installation, operation and maintenance information for flanged multi-port ball valves. This manual addresses lever operated ball valves only. Please refer
More informationINSTRUCTIONS PARTS LIST U.S. PAT: 6,874,404; 6,516,707; 6,223,645
3076-AFCM-000 INSTRUCTIONS PARTS LIST INSTRUCTIONS! This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. AQ Air Flow Control (3076-AFC3-000) (3076-AFC4-000) U.S. PAT: 6,874,404;
More informationAPCO ASU-SCAV & ASU-CAV SINGLE BODY COMBINATION AIR VALVES
APCO ASU-SCAV & ASU-CAV SINGLE BODY COMBINATION AIR VALVES Instruction D12039 December 2015 Instructions These instructions provide installation, operation and maintenance information for the. They are
More informationtrigger magazine release
Made in Germany www.umarexusa.com slide gas vent hammer barrel bushing recoil spring plug slide stop trigger safety trigger guard magazine release grip Government 1911 A1 S Cal. 9 mm P.A.K. (Blank Firing)
More informationModel Portable Eyewash
INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: haws@hawsco.com website: www.hawsco.com Model 7601.37 Portable Eyewash
More informationDC5A. Cyclone Separator Trap for Air. Copyright 2015 by TLV Co., Ltd. All rights reserved ISO 9001/ ISO MA-03 (DC5A) 19 June 2015
172-65205MA-03 (DC5A) 19 June 2015 ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Cyclone Separator Trap for Air DC5A Copyright 2015 by TLV Co., Ltd. All rights
More informationPCS 340 Core Saturator : 115 Volt : 230 Volt. Instruction Manual
PCS 340 Core Saturator 127-70: 115 Volt 127-70-1: 230 Volt Instruction Manual Updated 4/30/2015 Ver. 1.2 OFI Testing Equipment, Inc. 11302 Steeplecrest Dr. Houston, Texas 77065 U.S.A. Tele: 832.320.7300
More informationHAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS
HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS Page 1 of 20 Page 2 of 20 TABLE OF CONTENTS Safety Warnings
More informationCSO/STORMWATER MANAGEMENT. HYDROVEX FluidMoon Self-Adjusting Knife-Gate Regulator
CSO/STORMWATER MANAGEMENT HYDROVEX FluidMoon Self-Adjusting Knife-Gate Regulator HYDROVEX FLUIDMOON SELF-ADJUSTING KNIFE-GATE REGULATOR APPLICATION The Hydrovex FluidMoon Self-Adjusting Knife-Gate Regulator
More informationModel 9201E Tempered Water Blending System
INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: haws@hawsco.com website: www.hawsco.com Model 9201E Tempered Water Blending
More informationUE- 90- X X X X X X O P E R AT I N G M A N UA L 0 TO 90 HYDRAULIC UPENDER
UE- 90- X X X X X X O P E R AT I N G M A N UA L ADDRESS 2230 Brush College Road Decatur, IL 62526 Phone: 217-423-6001 Fax: 217-422-1049 E-mail: sales@alignprod.com www.alignproductionsystems.com UE-90-XXXXXX
More informationINDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES
INSTRUCTION MANUAL Installation Operation Parts Service IMPORTANT Record your Regulator model number and serial number here for easy reference: Model No. Serial No. Date of Purchase When ordering parts
More informationSeries 8500 Expansion Compensators. Catalog 674H
Series 8500 Expansion Compensators Catalog 674H 500 Laminated Bellows Expansion J Series 8500 on Joints Expansion Compensators Sizes 3/4" through 4" Threaded, welded, flanged and grooved steel pipe joints
More informationslide takedown lever magazine release
Made in Germany www.umarexusa.com manual safety extractor slide gas vent hammer trigger lock trigger P22 S guide rod takedown lever slide stop magazine release Cal. 9 mm P.A.K. (Blank Firing) OPERATING
More informationTECHNICAL DATA Q= C. Table 1 - Specifications
September 25, 2013 Pressure Regulation 537a 1. Description The Model B-3 Pilot Operated Pressure Control Valve is a factory assembled unit. The unit consists of a Model J-2 Halar coated Flow Control Valve,
More informationInstruction Sheet. SUPERSEDES: New EFFECTIVE: August 1, 2013
Instruction Sheet 102-492 5123-WH-N Lead Free (.25% Pb) Mixing Valve SUPERSEDES: New EFFECTIVE: August 1, 2013 Plant I.D. 001-4206 WARNING: Water temperatures above 120 F can cause serious injury. Mixing
More information2000 lb manual winch
2000 lb manual winch Model 41694 Operation Instructions Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission Oaks Blvd., Camarillo, CA 93011
More informationU S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.
U S E R M A N U A L 1600 SERIES OXYGEN REGULATOR 168715G (Shown) SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician. 300 Held Drive Tel: (+001) 610-262-6090
More informationINSTRUCTION MANUAL. Includes: OPERATION SETUP USE & CARE SERVICE. SPORTS ATTACK LLC
Electronic Baseball Pitching Machine baseball INSTRUCTION MANUAL PART NO. B-EHABA-100 REV022111 INSTRUCTION MANUAL Includes: OPERATION SETUP USE & CARE SERVICE SPORTS ATTACK LLC 800-717-4251 www.sportsattack.com
More informationNew AQF Filter Polymer Filtration System
New AQF Filter Polymer Filtration System Operator Manual Covering Serial Number 20002001 onwards February 2011 Index Disclaimer notice...3 Introduction...4 Important safety notices...5 Getting started...6
More informationAND OPERATION INSTRUCTIONS
ADI 2111-D Certified ISO 9001 MEDICAL FLOWMETER (Back Pressure Compensated Thorpe Tube) INSTALLATION AND OPERATION INSTRUCTIONS Before Installing or Operating, Read and Comply with These Instructions Controls
More information3800 SERIES END SUCTION PUMP REPAIR PARTS INDEX. Model Model 3804
Model 3801 Model 3804 3800 SERIES END SUCTION PUMP REPAIR PARTS INDEX NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party who maintains
More informationCSA Sample Draw Aspirator Adapter Operator s Manual
30-0951-CSA Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0367 Revision: 0 Released: 4/30/15 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating
More informationSTC 2KS/2KD Series Stainless Steel Angle Seat Valve
STC 2KS/2KD Series Stainless Steel Angle Seat Valve S T C TM Single Acting Double Acting List Price Port Size (NPT) Cv 2KS - 3/8 2KD - 3/8 $169.73 3/8 4.7 2KS - 1/2 2KD - 1/2 $183.90 1/2 4.7 2KS - 3/4
More informationTITAN FLOW CONTROL, INC.
PREFACE: This manual contains information concerning the installation, operation, and maintenance of Titan Flow Control (Titan FCI) WYE Type Strainers. To ensure efficient and safe operation of Titan FCI
More informationTOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual
TOP VALVE Pat. #5,857,486 & 5,944,050 Mid-Range Pressure 50 232 PSIG Back Pressure and Pressure Relief Valves Instruction Manual Please Note: This instruction manual provides detailed information and instructions
More informationModel TWBS.SH Tempered Water Blending System
INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 455 Kleppe Lane Sparks, NV 8943-6467 (775) 359-472 Fax (775) 359-7424 HAWS AG Bachweg 3 CH-340 Burgdorf Switzerland Haws Mfg. Pte Lt. 2A Sungei Kadet
More informationTOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual
TOP VALVE Pat. #5,857,486 & 5,944,050 High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves Instruction Manual PLEASE NOTE: This instruction manual provides information and instructions
More informationThis document to be used with Hurley traditional Davits
~ InstructIon Manual ~ This document to be used with Hurley traditional Davits WarnIngs WarnIng - Failure to install, maintain, protect, and operate the system properly can cause malfunction resulting
More informationUNIVERSAL GAS FRYER Instruction Manual Model #8065NS
Part No. 88847 Revised: August 2004 UNIVERSAL GAS FRYER Instruction Manual Model #8065NS Cincinnati, OH 45241-4807 USA GAS SAFETY PRECAUTIONS OPERATING INSTRUCTIONS UNPACKING AND ASSEMBLY After unpacking
More informationInstallation Operation Maintenance
682 Seal Cooler New generation seal cooler to meet and exceed the seal cooler requirements stated in the 4th Edition of API Standard 682 Installation Operation Maintenance Experience In Motion Description
More informationSterile Visual Flow Indicator
Sterile Visual Flow Indicator Sanitary Process Connection Installation / Operation / Maintenance Manual P.O. Box 1116 Twinsburg, OH 44087 Phone: 330/405-3040 Fax: 330/405-3070 E-mail: view@ljstar.com Web
More informationGAS FRYER Instruction Manual Model #5099NS
Part No. 89932 Revised: March 2004 GAS FRYER Instruction Manual Model #5099NS Cincinnati, OH 45241-4807 USA GAS SAFETY PRECAUTIONS GAS FUNNEL CAKE FRYER 2 MODEL #5099NS GAS FUNNEL CAKE FRYER SAFETY PRECAUTIONS
More informationInstallation, Operation and Maintenance Manual. TSV Temperature Shut-off Valve SPD Rev. 6 10/07
Installation, Operation and Maintenance Manual TSV Temperature Shut-off Valve SPD 13.1.2 Rev. 6 10/07 SENTRY EQUIPMENT CORP PO Box 127 Oconomowoc, WI 53066 USA Phone: 262.567.7256 Fax: 262.567.4523 Email:
More informationVORTEX REGULATOR Type WAB (UCY / CY-F / CE/V)
VORTEX REGULATOR Type WAB (UCY / CY-F / CE/V) UCY series, CY series, CE/V series, OP series Conical vortex regulator Type WAB-UCY (wet installation) Vertical vortex regulator Type WAB- CE/V (wet installation)
More informationINSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES
INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES THIS BOOKLET CONTAINS PROPRIETARY INFORMATION OF ADVANCED SPECIALTY GAS EQUIPMENT CORP. AND IS PROVIDED TO THE PURCHASER SOLELY FOR USE
More informationBermad Pressure Reducing. Model: 42T
Bermad Pressure Reducing Pilot Operated Pressure Control Valve Model: 42T Installation Operation Maintenance Manual (IOM) REV. 27.7.17 Page 1 of 12 Safety First BERMAD believes that the safety of personnel
More informationOPERATING INSTRUCTIONS Pressure Control System PCS-20 through PCS-100
107 W. Main Street Worthington, PA 16262 Phone: 724.297.3416 Fax: 724.297.5189 http://www.airtak.com OPERATING INSTRUCTIONS Pressure Control System PCS-20 through PCS-100 12-2007 TABLE OF CONTENTS PAGE
More informationHygienic Bubble Trap Installation and Operations Manual
Hygienic Bubble Trap Installation and Operations Manual Darren Bean / J. LaFleur 1/1/2010 Table of Contents 1.00 Warranty... 1 1.10 Exceptions... 1 1.20 Provisions... 1 2.00 Components... 1 2.10 Exploded
More informationACCU-MIX 1200 / / 26270
ACCU-MIX 1200 / 14100 / 26270 Model 102006 (1200) Model 102002 (14100) Model 102003 (26270) Pre filter is required when the water supply is from a in house un filtered well to retain the warranty. Pre
More informationStandard Gas Countertop Griddle
Standard Gas Countertop Griddle This manual contains important information regarding your unit. Please read the manual thoroughly prior to equipment set-up, operation and maintenance. Failure to comply
More informationSunset Swings By Health in Motion, LLC
Sunset Swings By Health in Motion, LLC Model 421 Lounge Swing Assembly and Operation Manual Record Serial Number Here www.sunsetswings.com by Health In Motion, LLC. 1/30/2013 Caution: READ! VERY IMPORTANT
More informationCAST IRON SAFETY VALVE TYPE 6301
CHARACTERISTICS The 6301 safety valve is dedicated to protect the equipment from potential overpressure. This is an automatic device that closes when the pressure conditions are back to normal. It is a
More informationAtmospheric relief valve type 1100 Installation and maintenance instructions
SAPAG 1. Description Sapag atmospheric relief valves type 1100 have been selected for installation because of their performance features, reliability and ease of maintenance. They are designed to protect
More informationINSTALLATION INSTRUCTIONS AT-SERIES ANCHOR ASSEMBLY PART NUMBER: F-04CAJP 450 LB. [204kg] MAXIMUM CAPACITY (PRO POOL LIFT)
INSTALLATION INSTRUCTIONS AT-SERIES ANCHOR ASSEMBLY PART NUMBER: F-04CAJP 450 LB. [204kg] MAXIMUM CAPACITY (PRO POOL LIFT) - WARNING- IMPORTANT SAFETY INSTRUCTIONS 1. READ AND FOLLOW ALL INSTRUCTIONS.
More informationOPERATION AND INSTRUCTION MANUAL Flat Roof Anchor Model: FRA250L-10X-CTS
OPERATION AND INSTRUCTION MANUAL Flat Roof Anchor Model: FRA250L-10X-CTS (Patent Pending) WARNING: ALL PERSONS USING THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS. FAILURE TO DO SO MAY RESULT
More informationHigh Pressure Inlet Kits for CONCOA BlendMites and BlendMasters
ADI 3210-A ADI 3210-A Certified ISO 9001 Certified ISO 9001 High Pressure Inlet Kits for CONCOA BlendMites and BlendMasters Warning: An appropriately sized pressure relief device downstream of the regulator
More informationCombination Air Valve
Combination Air Valve For Sewage and Wastewater Model C50 Installation, Operation and Maintenance Manual (IOM) Table of Contents General... Page 2 Safety... Page 2 Operational Data... Page 3 Materials
More informationTECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1
November 30, 1994 534 a 1. PRODUCT NAME VIKING 2" (50mm), 3" (75mm), 4" (100mm), 6" (150mm) 2. MANUFACTURER THE VIKING CORPORATION 210 N. Industrial Park Road Hastings, Michigan 49058 U.S.A. Telephone:
More informationIMPORTANT: RECEIVING INSTRUCTIONS:
Instruction Sheet Sidewinder Mechanical Bender IMPORTANT: RECEIVING INSTRUCTIONS: Visually inspect all components for shipping damage. If any shipping damage is found, notify carrier at once.shipping damage
More informationROPV R40 E Series User Manual
HARBIN ROPV INDUSTRY DEVELOPMENT CENTER ROPV R40 E Series User Manual For Use with the Following ROPV Pressure Vessel Models: R40 300E R40 450E Headquarters Tel:(+86)451-82267301 Fax:(+86)451-82267303
More informationRADROVER REAR RACK INSTALLATION MANUAL
RADROVER REAR RACK INSTALLATION MANUAL WWW.RADPOWERBIKES.COM We are here to help! Please contact us at SUPPORT@RADPOWERBIKES.COM or 1-800-939-0310 if you have questions. REV022216 Welcome Thanks you for
More informationJ Air and Water Kit Instructions Part# 02584
J Air and Water Kit Instructions Part# 02584 Unpacking Please open and inspect your package upon receipt. Your package was packed with great care and all the necessary packing materials to arrive to you
More informationU S E R M A N U A L AIR FLOWMETER. MODELS: 1MFA2001 (shown) 1MFA9001 CAUTION. ISO Certified
U S E R M A N U A L AIR FLOWMETER MODELS: 1MFA2001 (shown) 1MFA9001 ISO 13485 Certified Authorized Your EU local Representative: distributor: EMERGO EUROPE, INC. Molenstraat 15 2513866 BH -624 The -3952
More informationOxygen Concentrator. Installation and Operation Manual. ClearWater Tech, LLC. Integrated Ozone Systems
Oxygen Concentrator Installation and Operation Manual ClearWater Tech, LLC. Integrated Ozone Systems 850-E Capitolio Way, San Luis Obispo, Ca 93401 805-549-9724 Fax: 805-549-0306 E-mail: service@cwtozone.com
More informationAutomatic Non-freeze Valve NF6
172-65134MA-03 (NF6) 30 March 2015 ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Automatic Non-freeze Valve NF6 Copyright 2015 by TLV CO., LTD. All rights
More informationCylinder Tilt Saddle Instruction Manual
Cylinder Tilt Saddle Instruction Manual MODELS: SDT05, SDT10, SDT15, SDT25 SFA Companies 10939 N. Pomona Ave. Kansas City, MO 64153 Tel: 888-332-6419 - Fax: 816-448-2142 E-mail: sales@bvahydraulics.com
More informationTEST BENCH SAFETY VALVES ¼ - 5 DN10 DN125
TEST BENCH SAFETY VALVES ¼ - 5 DN10 DN125 Model: VC-40-VYC Table of contents 1. - Installing the test bench 1.1.1- Connecting the compressed air / nitrogen source 1.1.2- Maximum test pressure according
More informationMAINTENANCE AND OPERATING MANUAL
MAINTENANCE AND OPERATING MANUAL Cyclone condensate separator Type ASA EN EN Maintenance and operating manual Purpose and appropriate use Dear Customer, thank you for choosing our product. In order to
More information92831 TEL: (714) FAX:
Document No. 1800-75 Respiration Test Chamber Copyright 2010 Terra Universal Inc. All rights reserved. Revised September 2010 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton, CA
More information453 Series Steam Heated Vaporizing Regulator
ADI 0453A Certified ISO 9001:2000 453 Series Steam Heated Vaporizing Regulator INSTALLATION AND OPERATION INSTRUCTIONS Before Installing or Operating, Read and Comply with These Instructions Controls Corporation
More informationENERGY BLADE 3K4. Energy Blade Installation Instructions
ENERGY BLADE 3K4 Energy Blade Installation Instructions 1 Contents General information 2 Scope of these instructions 2 Product information 2 Designated use 3 Warranty 3 Safety instructions 4 Assembly and
More informationIndex Table. Model 794. Installation, Operating and Maintenance Instructions
CLOCKWISE MANUAL MAKING INTO CCW TABLE Index Table Model 794 Installation, Operating and Maintenance Instructions Black & Webster Products Division 545 Hupp Ave. P.O. Box 831, Jackson, Michigan 49204 2009
More informationRK-IR Sample Draw Aspirator Adapter Operator s Manual
30-0951RK-IR Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0018RK Revision: A Released: 6/2/10 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment
More informationNeedle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2
Serial No. H-V024-E-7 Needle valve User s Manual Contents (1) Be sure to read the following warranty clauses of our product 1 (2) General operating instructions 2 (3) General instructions for transportation,
More informationUSER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.
USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS CAUTION Federal (USA) law restricts this device to sale by or on the order of a physician. RECEIVING / INSPECTION Remove the Precision Medical,
More informationRevolution Gurney Attachment
Revolution Gurney Attachment PART NUMBER: F-30RSA-S2 (2nd SERIES) WEIGHT CAPACITY: 350 POUNDS - STANDARD REVOLUTION 300 POUNDS - DEEP DRAFT REVOLUTION MANDATORY LEAVE THIS MANUAL WITH LIFT OWNER Read &
More information8675/8677/8678 OWNER S MANUAL
8675/8677/8678 OWNER S MANUAL SERIAL NUMBER: DATE OF MANUFACTURE: 8675 MAXIMUM PATIENT WEIGHT: 250 LBS. 8677/8678 MAXIMUM PATIENT WEIGHT: 375 LBS. 1316 Eisenhower Blvd Johnstown, PA 15904 (814) 266 8726
More informationHAYWARD FLOW CONTROL TFS SERIES FLOW METER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
HAYWARD FLOW CONTROL TFS SERIES FLOW METER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS PLEASE READ THE FOLLOWING INFORMATION PRIOR TO INSTALLING AND USING HAYWARD TFS SERIES FLOW METERS. FAILURE
More informationAPCO ARV CLEAN WATER AIR RELEASE VALVES. Model 50A
APCO ARV CLEAN WATER AIR RELEASE VALVES Model 50A Instruction D12013 February 2017 Instructions These instructions provide installation, operation and maintenance information for APCO ARV Clean Water Air
More informationInstallation, Operation and Maintenance Manual
Installation, Operation and Maintenance Manual Model H2F H2Flow Anti-Scale System Chemical-Free, Salt-Free Scale Prevention Introduction The H2Flow Anti-Scale System will condition the tap water providing
More informationInstallation and Operation Manual
Installation and Operation Manual WIKA FLR-SBDF / BLR-SBDF Magnetic Level Transmitter (Please retain for future usage) Contact: Gayesco-WIKA USA, L.P. 229 Beltway Green Boulevard Pasadena, TX 77503 www.wika.com
More information3" UC Ultra-Chuck Durable Lightweight Air Inflated Bladder Chuck Operation/Repair Manual. (76.2 mm) DOUBLE E COMPANY, INC.
3" UC-3000 (76.2 mm) Ultra-Chuck Durable Lightweight Air Inflated Bladder Chuck Operation/Repair Manual DOUBLE E COMPANY, INC. 319 Manley Street, West Bridgewater, MA 02379 U.S.A. Tel: (508) 588-8099 /
More informationTECHNICAL DATA NOTICE
Page 1 of 5 1. DESCRIPTION FomTec BFZ Inductors are used to mix foam concentrate with water when the foam concentrate is supplied from a tank at atmospheric pressure. The BFZ inductor can be installed
More informationSTYLE 3414/3416 & 3421/3423 Apollo Monitor with Foldaway Legs OPERATING & MAINTENANCE INSTRUCTIONS
STYLE 3414/3416 & 3421/3423 Apollo Monitor with Foldaway Legs OPERATING & MAINTENANCE INSTRUCTIONS The Akron Style 3414/3416 & 3421/3423 Apollo Monitor is designed to provide efficient trouble-free operation
More informationInstallation Instructions JATCO Environmental Protection Tank Model J-7000
Installation Instructions JATCO Environmental Protection Tank Model J-7000 The JATCO Environment Tank must be installed at a level which will allow the waste liquids to be disposed of to gravity flow into
More informationNorrsken Family Booklet
Section 1: Introduction Low Energy Designs produce efficient and effective LED based lighting products for commercial, retail and industry purposes. Each product may contain specific details on its operation
More informationNeotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions
Before installation these instructions must be fully read and understood 2 Safety Please read these instructions carefully. 2.1 General danger potential Not paying attention to this instruction Incautious
More informationInstallation and Operating Instructions
Installation and Operating Instructions Neptune Caisson Pump Section 1 Shipment Inspection........Page 2 Section 2 Pre-Installation Checklist....Page 3 Section 3 Installation..............Page 4 Section
More informationFor use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum WARNING: FOR OUTDOOR USE ONLY
For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum : FOR OUTDOOR USE ONLY Small Tank LP Kit (STLPK) Installation & Operation Instructions Installation We suggest
More informationInstallation Instructions JATCO Environmental Protection Tank Model J-5000CX
Installation Instructions JATCO Environmental Protection Tank Model J-5000CX The JATCO Environment Tank must be installed at a level which will allow the waste liquids to be disposed of to gravity flow
More informationSSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR
S S F U SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR MACHINERY DIVISION OWNER S MANUAL UNIT INSTRUCTIONS Please follow all SSFU Safety Instructions. Contact your Duro Dyne Tech Service if you have
More informationModels: C62/63/64-A/D
Installation & Service C62-991-24A3 Models: C62/63/64-A/D Diaphragm Bypass Pressure Regulating Valves IMPORTANT Record your pump model number and serial number here for easy reference: Model No. Serial
More informationSize : Connection Ends : Min Temperature : Max Temperature : Materials : Cast iron body
Size : Connection Ends : Min Temperature : Max Temperature : DN 50 to 200 Flanged ISO PN 10/16 ( ISO PN16 for DN200 ) 0 C + 50 C Max Pressure : 16 Bars Specifications : Tangential type Dry dial Magnetic
More information