FLOWSIC100 Flare Gas massflow measuring device. Gas massflow measuring device for flare gas applications

Size: px
Start display at page:

Download "FLOWSIC100 Flare Gas massflow measuring device. Gas massflow measuring device for flare gas applications"

Transcription

1 Product information FLOWSIC100 Flare Gas massflow measuring device Gas massflow measuring device for flare gas applications

2 Measurement certainty and precision even under extreme application conditions FLOWSIC100 Flare. The measurement of flare gas in the chemical and petrochemical industry is widely considered to be the leading discipline in gas flow measurement. In no other area do the application conditions and resulting requirements for measuring technology pose such a challenge. The primary area of application involves calculating greenhouse gas emissions based on the amount of flare gas measured in accordance with regulatory requirements. FLOWSIC100 Flare has been developed for precisely this purpose. State-of-theart sensor technology and high-quality components ensure highly accurate and reliable measurement with the utmost failure safety protection even under extreme conditions on oil rigs and at remote oil fields. Even very low flow rates can be accurately detected, the measuring device is also suitable for continuous process monitoring and optimization as well as for detecting the smallest leaks in the flare gas network. 2 FLOWSIC100 Flare Gas massflow measuring device SICK /

3 Performance and durability FLOWSIC100 Flare is based on more than 30 years of experience in ultrasonic sensor technology at SICK and offers outstanding performance and durability. Changing gas compositions and corrosive components have no impact on the measurements, as all parts that come into contact with the gas flow are made of resistant materials. Reliable low flow measurements high signal time resolution combined with state-of-the-art signal processing mean that even very small amounts of gas can be detected accurately with flow velocities of close to zero. s a result, the measuring device offers excellent reliability when monitoring processes and detecting leakages in the flare gas system. Works even under extreme conditions The optimized sensor design even allows measurements to be taken during emergency system shutdowns and at extreme gas velocities of up to 120 m/s. In tandem with a high-speed measuring algorithm, the measuring process is also safeguarded in the event that conventional ultrasonic technology has failed due to extreme system noise and turbulence. Excellent application reliability The high power EX/EX-RE model is specially designed for use in pipes with large diameters of up to 72 inches and with extremely challenging gas compositions. Even flare gas with excessive contamination (e.g., associated gas) does not affect the measurement. ll device versions meet explosion protection requirements according to TEX, CS, and IECEx. Comprehensive diagnostic functions n automatic control cycle checks the device function periodically, while the integrated self-diagnosis continually monitors all important function parameters. In the event of impermissible deviations that could affect the measurement result, warning messages are generated so that maintenance can be planned in time. special testing procedure allows the device functions to be verified according to factory standards with ease even for quality assurance in the field. Ideal configuration FLOWSIC100 Flare is available as 1- or 2-path version. The 2-path version offers higher measurement accuracy also in the case of flow conditions that are less than ideal. The probe version FLOWSIC100 EX-PR is a special device version providing simple and cost-saving installation on one side of the flare gas line. Device retraction mechanism allows sensors to be replaced quickly and simply during plant operation. Product overview FLOWSIC100 Flare is available in three different versions, each capable of overcoming all of the difficulties that arise from the measuring task. These include extreme flow conditions, challenging gas compositions, and special installation and ambient conditions. FLOWSIC100 EX-S FLOWSIC100 EX/EX-RE FLOWSIC100 EX-PR "Cross-duct" high-speed version (patent pending) 90 nozzle installation Retractable under process conditions Hermetically sealed stainless steel and titanium probes TEX, IECEx, and CS approved for use in hazardous areas "Cross-duct" high-speed version for exceptionally large nominal pipe sizes and gaseous mixtures with a high CO2 content (patent pending) Retractable under process conditions Hermetically sealed stainless steel and titanium probes TEX, IECEx, and CS approved for use in hazardous areas High-speed "probe version" (patent pending) Single nozzle installation only Retractable under process conditions Hermetically sealed titanium probe TEX, IECEx, and CS approved for use in hazardous areas / FLOWSIC100 Flare Gas massflow measuring device SICK 3

4 Cutting-edge ultrasonic technology for one of the most demanding applications in gas flow measurement. Ultrasonic technology by SICK FLOWSIC100 Flare combines state-of-the-art ultrasonic sensor technology with proven, high-precision signal processing from the field of custody transfer measurement. The ultrasonic sensors can operate even under atmospheric pressure conditions without any restrictions on performance. Under practical application conditions, the acoustic signal resolution reaches a value of up to +/ 5 ns, which enables gas velocities of up to m/s to be detected, and the tiniest quantities of flare gas to be reliably recorded. To ensure this performance, every device in the FLOWSIC100 Flare series passes a specially developed testing procedure under zero point conditions, in which extremely demanding performance criteria must be met. The upper measuring range presents yet a further challenge: In the case of emergency shutdowns in the flare gas system, the gas velocity can reach well over 100 m/s within just a few seconds, leading to heavy background noise, gas flow turbulence, and signal drift effects. This is where a good flow measuring device comes into its own. FLOWSIC100 Flare has already recorded low flow measurements in the flare gas system, now it is switching its attention to extreme measuring. Its unique, streamlined sensor design smoothens turbulence and minimizes background noise on the sensor surface. Even at 120 m/s. High-speed sensor design n innovative sensor design has been developed for the FLOWSIC100 Flare. The ultrasonic sensors are embedded in a flow-optimized contour that has been specially designed for high gas flows. The unique sensor design reduces flow noise and signal drift to a minimum and provides stable and reliable readings. The optimized 2-stage signal algorithm offers optimum signal processing across the entire measuring range. Flow turbulence, signal dispersion disturbed No flow turbulence, undisturbed signal dispersion Ultrasonic sensor embedded in flow-optimized contour Conventional sensor High-speed sensor Outstanding reliability and durability Significant fluctuations in gas compositions and/or corrosive process conditions are taken into account by selecting specially adapted ultrasonic sensors. The broadband transmission behavior and large signal amplitudes ensure a reliable measuring operation in a variety of gas mixtures with a molecular weight of between 2 and 120 g/mol. The large signal range and good coverage of the SICK ultrasonic sensors are yet further factors of success for optimal functioning of the device. Depending on the gas mixture, specially adapted sound frequencies with optimal transmission properties can be used. "High-power sensors" allow a cross-duct measurement in nominal pipe sizes of up to 72 inches and sound-absorbing gases with a high carbon dioxide content. The sensors are made exclusively in hermetically sealed, solid metal designs, preferably from titanium. For particularly aggressive gas compositions, highly-resistant alloys (e.g., Hastelloy) are used to ensure durability. 4 FLOWSIC100 Flare Gas massflow measuring device SICK /

5 Device testing to factory standards To provide regular evidence of its functionality, FLOWSIC100 Flare can also be checked in the field according to SICK factory standards. Zero point deviation and time-of-flight measurements are checked in a specially designed testing box and adjusted if necessary. By comparing the theoretical and measured sound velocity under defined test conditions (pressure, temperature, humidity), it is possible to assess the accuracy of the time-of-flight measurement and provide evidence of its zero point stability with ease. Even if the measuring device cannot be removed from the measuring line, a periodic functional test is carried out via an integrated control cycle (zero point test, span test). Continuous self-diagnosis Using ultrasonic technology parameters such as automatic gain control, error rate, and signal-noise ratio, the device is automatically monitored for compliance with the permitted operating range using the integrated self-diagnosis. Impermissible deviations from the parameters can be signaled immediately by means of a continuous internal evaluation before the measuring function is even affected. This means that any signs of wear, sensor contamination, or background noise can be detected and eliminated as early as possible. By comparing diagnostic values when commissioning the device ("fingerprint") and at any given point in the future, it is furthermore possible to identify changes in process conditions. In this case, device performance can be ensured even under special challenging conditions by parameter optimization. Thus application reliability can be increased. Under conditions where conventional ultrasonic technology has already failed. Device diagnosis by evaluating gain control values using the example of a 2-path measuring system and a measuring operation of one year utomatic gain control (GC) during device commissioning utomatic gain control (GC) after one year of measuring operation Measuring path 1 Measuring path 2 GC sensor B GC sensor B GC sensor B GC sensor B 34,8 GC sensor B 34,5 Warning threshold Measuring path 1 33,1 GC sensor B 33,2 32,0 GC sensor B 34,7 Measuring path 2 32,5 GC sensor B 32, Warning threshold utomatic gain control (GC) in db utomatic gain control (GC) in db / FLOWSIC100 Flare Gas massflow measuring device SICK 5

6 FLOWSIC100 Flare Gas massflow measuring device Reliable gas flow measurement in flare gas applications Product description The FLOWSIC100 Flare measures the flow rate of flare gas. The device operates according to the principle of ultrasonic transit time difference measurement and has been specially developed for the high requirements involved in measuring flare gas. With their flow-optimized design, the innovative sensors reduce flow-generated noise and signal drift when gas velocities are particularly high and even ensure measurement availability under extreme conditions. Even very low gas flows can be measured with precision. The FLOWSIC100 EX-S and EX/EX-RE devices take integral measurements across the entire nominal pipe size up to 72 inches and ensure stable readings even when flow conditions are less than ideal. The FLOWSIC100 EX-PR probe version is installed on one side of the pipe, making it particularly cost-effective. The compulsory MCUP control unit is used for signal input and output, and for calculating process variables such as standard flow, molecular weight, and mass flow. ll devices are retractable under process conditions. t a glance High-resolution measurement close to zero Innovative sensor design for very high gas velocities Reliable and accurate measurement even under atmospheric pressure Function testing possible at the installation site according to factory standards Integral measurement for nominal pipe sizes of up to 72 inches Probe version for single-sided installation Hermetically sealed sensors made of titanium or stainless steel TEX, IECEx, and CS explosion protection C US dditional information Fields of application Detailed technical data Ordering information Dimensional drawings Your benefits Continuous process monitoring through precise measurement of very small gas volumes. High measurement availability even in the case of emergency shutdowns with gas velocities of up to 120 m/s. High measurement reliability thanks to continuous function monitoring and extended diagnosis. Precise measurement results even in the case of non-ideal flow conditions and large nominal pipe sizes. Excellent application reliability even with significant fluctuations in gas compositions and contaminated gases. Minimal installation effort due to single-sided installation of the EX-PR probe version. Cost-effective installation of the control unit possible in the safe area. Complete solution with a spool piece and factory-set device parameters for Plug&Play installation For more information, just enter the link and get direct access to technical data, CD design models, operating instructions, software, application examples, and much more. 6 FLOWSIC100 Flare Gas massflow measuring device SICK /

7 Gas massflow measuring device FLOWSIC100 Flare Fields of application Calculation of carbon dioxide emissions in petrochemical plants and during oil production to comply with legal regulations and guidelines. Reduction of carbon dioxide emissions to a minimum by measuring flare gas quantities continuously and precisely (basis for calculating carbon dioxide emissions). Monitoring and optimization of petrochemical processes, accurate mass balancing. Leakage detection in the flare gas system and reduction of gas wastage to a minimum. Control of steam injection in flare gas combustion and reduction of pollutant emissions. Detailed technical data The precise device specifications and product performance data may vary and are dependent on the respective application and customer specifications. FLOWSIC100 Flare Measured variables Mass flow, volumetric flow at actual and standard conditions, molecular weight, gas volume and mass, gas velocity, gas temperature, sound velocity Number of measuring paths 1, 2 Measurement principle Ultrasonic transit time difference measurement Measurement medium Hydrocarbon mixture with and without H2 content Repeatability 0.2 % at 10 m/s Measurement uncertainty Volumetric flow, actual condition (1-path measurement) Volumetric flow, actual condition (2-path measurement) ± 1.5% to 5% of the measured value (in the range of 0.3 m/s to the upper range value) 1 ± 0.5% of the measured value (in the range of 1 m/s to the upper range value) 1,2 ± 1% to 3% of the measured value 1 (in the range of 0.3 m/s to the upper range value) 1 ± 0.5% of the measured value (in the range of 1 m/s to the upper range value) 1,2 Mass flow (1-path measurement) ± 2.5 % to 5% of the measured value (in the range of 0.3 m/s to the upper range value) 1,3 Mass flow (2-path measurement) ± 2 % to 4% of the measured value (in the range of 0.3 m/s to the upper range value) 1,3 Molecular weight < 2% of the measured value (in the range of 2 to 120 kg/kmol) 3 1 For fully developed flow profiles 2 fter flow calibration 3 Hydrocarbon mixtures with < 10% of non-hydrocarbonic content Resolution m/s Gas temperature Standard: 70 C to +180 C High-temperature zone 1: 70 C to +280 C High-temperature zone 2: 70 C to +260 C Low temperature: 196 C to +100 C (not for FL100 EX/EX-RE zone 1 and CI I, Div1) Operating pressure 0.5 bar (g) to 16 bar (g) mbient temperature Sensor, ignition group IIC T4 40 C C 50 C C optional Sensor, ignition group IIC T6-40 C C 50 C C optional MCUP control unit, non-ex -40 C C MCUP control unit, CI I, Div2, zone 2-25 C C 115/230 V C MCUP control unit, CI I, Div2, zone 2 24 V DC -40 C C MCUP control unit, zone 1-40 C C Storage temperature 40 C C 50 C C optional mbient humidity 95 % relative humidity Electrical safety CE / FLOWSIC100 Flare Gas massflow measuring device SICK 7

8 FLOWSIC100 Flare Gas massflow measuring device FLOWSIC100 EX-S Measuring range m/s Span 4000 : 1 Nominal pipe size Ex approvals 1-path measurement 2-path measurement TEX IECEx NEC/CEC (US/C) Enclosure rating TEX zone 1 with terminal box TEX zone 1 without terminal box TEX zone 2 with terminal box NEC/CEC (US/C) Dimensions (W x H x D) Weight FLOWSIC100 EX/EX-RE 4 to 24 inches, depending on gas composition inches, depending on gas composition II 1/2 G Ex d [ia] IIC T4 II 1/2 G Ex de [ia] IIC T4 Optional: Temperature class T6; Ex zone 0 for ultrasonic transducers II 3 G Ex n IIC T4 Gc Ex d [ia] IIC T4 Optional: Temperature class T6; Ex zone 0 for ultrasonic transducers CI I, Div 1 Group B, C, D T4 Ex/Ex d [ia] IIB + H2 T4 Optional: Temperature class T6 CI I, Div 2 Group, B, C, D T4 Ex/Ex n [ia] IIC T4 IP65 IP65/IP67 IP65 Enclosure type 4, IP65 Details, see dimensional drawings 11 kg Measuring range 0.03 to 120 m/s Span 4000 : 1 Nominal pipe size 1-path measurement inches, depending on gas composition 2-path measurement inches, depending on gas composition Ex approvals TEX II 2 G Ex d IIC T4 II 2 G Ex de IIC T4 Optional: Temperature class T6 II 3 G Ex n IIC T4 Gc IECEx Ex d IIC T4 Optional: Temperature class T6 NEC/CEC (US/C) CII, Div 1 Group B, C, D, T4 Ex/Ex d IIB + H2 T4 Optional: Temperature class T6 CII, Div 2 Group, B, C, D, T4 Ex/Ex n IIC T4 Enclosure rating TEX zone 1 with terminal box TEX zone 1 without terminal box TEX zone 2 with terminal box NEC/CEC (US/C) Dimensions (W x H x D) Weight IP65 IP65/IP67 IP65 Enclosure type 6, IP65/67, single seal Details, see dimensional drawings 14 kg 8 FLOWSIC100 Flare Gas massflow measuring device SICK /

9 Gas massflow measuring device FLOWSIC100 Flare FLOWSIC100 EX-PR Measuring range m/s Span 3000 : 1 Nominal pipe size Ex approvals 1-path measurement 2-path measurement TEX IECEx NEC/CEC (US/C) Enclosure rating TEX zone 1 with terminal box TEX zone 1 without terminal box TEX zone 2 with terminal box NEC/CEC (US/C) Dimensions (W x H x D) Weight inches, depending on gas composition inches, depending on gas composition II 1/2 G Ex d [ia] IIC T4 II 1/2 G Ex de [ia] IIC T4 Optional: Temperature class T6; Ex zone 0 for ultrasonic transducers II 3 G Ex n IIC T4 Gc Ex d [ia] IIC T4 Optional: Temperature class T6; Ex zone 0 for ultrasonic transducers CI I, Div 1 Group B, C, D T4 Ex/Ex d [ia] IIB + H2 T4 Optional: Temperature class T6 CI I, Div 2 Group, B, C, D T4 Ex/Ex n [ia] IIC T4 IP65 IP65/IP67 IP65 Enclosure type 4, IP65 Details, see dimensional drawings 32 kg MCUP control unit Description Ex approvals Enclosure rating nalog outputs nalog inputs Digital outputs Digital inputs TEX IECEx NEC/CEC (US/C) Ex zone 1 version Ex zone 2/Div 2 version Non-Ex version Unit for controlling the sender/receiver units, and offsetting, evaluating, and outputting measured value data II 2 G Ex de IIC T6 II 3 G Ex n IIC T4 Gc Ex de IIC T6 CS Cl I, Div 2; Cl I, zone 2 group, B, C, D T4 Ex/Ex n IIC T4 IP66 Enclosure type 4, IP66 IP66, IP20 (19-inch version) 1 output 0/2/ m, 500 Ohm ccording to NMUR NE43 (Standardization ssociation for Measurement and Control); up to 7 outputs when I/O modules are used (optional) 2 inputs /10 V or 2 inputs m without galvanic isolation; up to 6 outputs when I/O modules are used (optional) 5 relay contacts: 48 V DC/1 30 V DC/1 for MCUP zone 2 and Div2 volt-free, for status signals up to 7 outputs when I/O modules are used (optional) pulse/frequency output (optional) 2 inputs For connecting volt-free contacts / FLOWSIC100 Flare Gas massflow measuring device SICK 9

10 FLOWSIC100 Flare Gas massflow measuring device Interfaces Bus protocol Display Operation Dimensions (W x H x D) Weight Electrical connection Non Ex-protected version Zone 1 version Zone 2/Div 2 version Power consumption Options USB 1.1 (service interface) RS232 (service interface) RS485 (Ex versions only) Digital transmitter interface (via optional interface module) Interface module (optional) Ethernet TCP/IP, (via optional interface module) Modbus (via optional interface module) Hartbus (via optional interface module) Profibus (via optional interface module) Foundation fieldbus (via optional interface module) Modbus TCP (via optional interface module) LC display Status LEDs: "Power", "Maintenance", and "Fault" Via LC display or SOPS ET software Details, see dimensional drawings 22 kg Depending on version V C, 50/60 Hz Option: 24 V DC V C, 50/60 Hz Option: 24 V DC 115/230 V C automatic switch-over Option: 24 V DC pprox. 20 W Interface module(s) I/O modules Ordering Information Our regional sales organization will help you to select the optimum device configuration. Dimensional drawings Dimensions in mm Sender/receiver units S/R unit, type FLOWSIC100 EX-S, not retractable 171, ,5 155, ,7 1 Sender/receiver unit (analog), for TEX zone 1/IECEx, TEX zone 2, and CS CI I, Div1/Div2 2 Sender/receiver unit (digital), with electronics unit for TEX zone 2 10 FLOWSIC100 Flare Gas massflow measuring device SICK /

11 Gas massflow measuring device FLOWSIC100 Flare S/R unit, type FLOWSIC100 EX-S, retractable , , Sender/receiver unit (analog), for TEX zone 1 and Ex zone 2, and CS Cl I, Div 1/Div 2 2 Sender/receiver unit (digital), with electronics unit for TEX zone 2 120,7 S/R unit, type FLOWSIC100 EX, not retractable 267, ,5 155, ,4 120,7 Sender/receiver unit (digital), with electronics unit for TEX zone 2 S/R unit, type FLOWSIC100 EX-RE, not retractable 267,5 511,5 115, , ,4 120,7 Sender/receiver unit (digital), with electronics unit for TEX zone / FLOWSIC100 Flare Gas massflow measuring device SICK 11

12 FLOWSIC100 Flare Gas massflow measuring device S/R unit, type FLOWSIC100 EX-PR, not retractable 273, , ) 120 Sender/receiver unit (digital), with electronics unit for TEX zone 2 1) Nominal length 220 mm for pipe diameters of up to 48 inches; Nominal length 350 mm for pipe diameters between > 48 and 72 inches Ø 190 Ø 152,4 S/R unit, type FLOWSIC100 EX-PR, retractable 273, , ) 120 Ø 190 Ø 152,4 Sender/receiver unit (digital), with electronics unit for TEX zone 2 2) Nominal length 400 mm for pipe diameters of up to 48 inches Nominal length 530 mm for pipe diameters between > 48 and 72 inches Electronic unit dimensions , Electronics unit with sender/receiver unit (digital) terminal box for TEX zone 1 2 Electronics unit for the sender/receiver unit (digital) for TEX zone 1/IECEx and CS CI I, Div1/Div2 12 FLOWSIC100 Flare Gas massflow measuring device SICK /

13 Gas massflow measuring device FLOWSIC100 Flare Mounting stud Mounting stud for type FLOWSIC100 EX-S Mounting stud for type FLOWSIC100 EX, EX-RE R 152,4 R 152,4 133,5 120, ,7 Mounting stud for type FLOWSIC100 EX-PR R Ø Ø 152,4 Ball valves 2-inch ball valve, standard temperature, for type FLOWSIC100 EX-S, EX, and EX-RE 2-inch ball valve, high temperature, for type FLOWSIC100 EX-S, EX, and EX-RE 227 Ø 152,4 Ø 120,7 246 Ø 152,4 Ø 120,7 178 Ø Ø 50 2-inch ball valve, low temperature, for type FLOWSIC100 EX-S, EX, and EX-RE ,4 120, Ø / FLOWSIC100 Flare Gas massflow measuring device SICK 13

14 Meas FLOWSIC100 Flare Gas massflow measuring device 3-inch ball valve, standard temperature, for type FLOWSIC100 EX-PR 3-inch ball valve, high temperature, for type FLOWSIC100 EX-P 283 Ø 190,5 Ø 152,4 203 Ø 76 3-inch ball valve, low temperature, for type FLOWSIC100 EX-PR 450 Ø ,5 181,5 203 Ø 80 Control unit MCUP, wall housing, compact design Ø 190,5 Ø 152,4 203 Ø FLOWSIC100 Flare Gas massflow measuring device SICK /

15 Gas massflow measuring device FLOWSIC100 Flare MCUP, wall housing, medium design Ø Wall housing for TEX zone 2 and safe areas 2 Wall housing for CS CII, Div2 MCUP, Exd/Exe housing, size 4, aluminum Ø Wall housing for TEX zone / FLOWSIC100 Flare Gas massflow measuring device SICK 15

16 FLOWSIC100 Flare Gas massflow measuring device MCUP, Exd/Exe housing, stainless steel , ,5 Ø Wall housing for TEX zone 1 MCUP, 19-inch rack 132, FLOWSIC100 Flare Gas massflow measuring device SICK /

17 Notes / FLOWSIC100 Flare Gas massflow measuring device SICK 17

18 Notes 18 FLOWSIC100 Flare Gas massflow measuring device SICK /

19 Services search online and order Search online quickly and safely with the SICK Finders Efficiency with the e-commerce tools from SICK Product pplications Literature Service Connection diagram ccessories Spare part Software Product Finder: We can help you to quickly target the product that best matches your application. pplications Finder: Select the application description on the basis of the challenge posed, industrial sector, or product group. Literature Finder: Go directly to the operating instructions, technical information, and other literature on all aspects of SICK products. Find out prices and availability: Determine the price and possible delivery date of your desired product simply and quickly at any time. Request or view a quote: You can have a quote generated online here. Every quote is confirmed to you via . Order online: You can go through the ordering process in just a few steps. For safety and productivity: SICK LifeTime Services SICK LifeTime Services is a comprehensive set of high-quality services provided to support the entire life cycle of products and applications from system design all the way to upgrades. These services increase the safety of people, boost the productivity of machines and serve as the basis for our customers sustainable business success. T R I N CONSULT SICK LifeTime Services S UP P OR T Consulting & Design Globally available experts for cost-effective solutions Product & System Support Fast and reliable, by telephone or on location Verification & Optimization Checks and recommendations for increased availability RETROF IT CH ECK Upgrade & Retrofits Uncovers new potential for machines and systems Training & Education Employee qualification for increased competitiveness / FLOWSIC100 Flare Gas massflow measuring device SICK 19

20 / ITL Pre USmod int40 SICK at a glance SICK is a leading manufacturer of intelligent sensors and sensor solutions for factory, logistics, and process automation. With more than 6,000 employees and over 40 subsidiaries worldwide, we are always close our customers. unique range of products and services creates the perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and preventing damage to the environment. We have extensive experience in various industries and understand their processes and requirements. With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe, sia and North merica, system solutions are tested and optimized in accordance with customer specifications. ll this makes us a reliable supplier and development partner. Comprehensive services round out our offering: SICK LifeTime Services provide support throughout the machine life cycle and ensure safety and productivity. For us, that is Sensor Intelligence. Worldwide presence: ustralia, Belgium/Luxembourg, Brasil, Ceská Republika, Canada, China, Danmark, Deutschland, España, France, Great Britain, India, Israel, Italia, Japan, México, Nederland, Norge, Österreich, Polska, România, Russia, Schweiz, Singapore, Slovenija, South frica, South Korea, Suomi, Sverige, Taiwan, Türkiye, United rab Emirates, US. Please find detailed addresses and additional representatives and agencies in all major industrial nations at: SICK G Waldkirch Germany

Product information. Gas Gas massflow measuring devicefor

Product information. Gas Gas massflow measuring devicefor Product information FLOWSIC100 Flare Gas Gas massflow measuring devicefor flare gas applications Measurement certainty and precision even under extreme application conditions FLOWSIC100 Flare. The measurement

More information

FLOWSIC100 Flare Challenges in Ultrasonic Flare meter field installations. History of Evolution

FLOWSIC100 Flare Challenges in Ultrasonic Flare meter field installations. History of Evolution FLOWSIC100 Flare Challenges in Ultrasonic Flare meter field installations Mart Gloudemans, Sebastian Stoof, Sven Holzbächer SICK Germany History of Evolution 1 Introduction SICK FLOWSIC100 has track record

More information

Online data sheet FLOWSIC30 GAS FLOW METERS

Online data sheet FLOWSIC30 GAS FLOW METERS Online data sheet A B C D E F H I J K L M N O P Q R S T Ordering information LTRASONIC GAS FLOW METER FOR CTION Type Part no. On request The exact device specifications and performance data of the product

More information

A review of best practices for Selection, Installation, Operation and Maintenance of Gas meters for Flare Applications used for Managing facility

A review of best practices for Selection, Installation, Operation and Maintenance of Gas meters for Flare Applications used for Managing facility A review of best practices for Selection, Installation, Operation and Maintenance of Gas meters for Flare Applications used for Managing facility mass balance and compliance 1. What, When and Why? 2. Flare

More information

DigitalFlow GF868 Panametrics Flare Gas Mass Ultrasonic Flowmeter with Extended Performance Range

DigitalFlow GF868 Panametrics Flare Gas Mass Ultrasonic Flowmeter with Extended Performance Range DigitalFlow GF868 Panametrics Flare Gas Mass Ultrasonic Flowmeter with Extended Performance Range Applications The DigitalFlow GF868 flowmeter is a complete ultrasonic flow metering system for: Flare gas

More information

Online data sheet FLOWSIC500 GAS FLOW METERS

Online data sheet FLOWSIC500 GAS FLOW METERS Online data sheet FLOWSI500 FLOWSI500 A F H I J K L M N O P Q R S T US Ordering information Type FLOWSI500 Part no. On request The exact device specifications and performance data of the product may deviate

More information

Flow metering in gases Introduction to COMBIMASS family

Flow metering in gases Introduction to COMBIMASS family Flow metering in gases Introduction to COMBIMASS family - physical principle, basic information - different types of instruments, pricing & delivery time Sales Training Germany October 17 th to 19 th,

More information

Ultrasonic Flowmeter USZ 08

Ultrasonic Flowmeter USZ 08 Ultrasonic Flowmeter USZ 08 PRODUCT INFORMATION Reliable Measurement of Gas Fields of application, method of operation and construction 2 Fields of application The ultrasonic flowmeter is an advanced measuring

More information

DigitalFlow GF868 Panametrics Flare Gas Mass Ultrasonic Flowmeter. GE Sensing. Features. Applications

DigitalFlow GF868 Panametrics Flare Gas Mass Ultrasonic Flowmeter. GE Sensing. Features. Applications Applications Features The DigitalFlow GF868 flowmeter is a complete ultrasonic flow metering system for: Flare gas Track down or prevent losses from leakage with positive material identification Account

More information

KMT. Thermal Mass Flow Meter. for Compressed Air and Gases. Measuring range: m3n/h m3 N

KMT. Thermal Mass Flow Meter. for Compressed Air and Gases. Measuring range: m3n/h m3 N Thermal Mass Flow Meter for Compressed Air and Gases measuring monitoring analysing KMT Measuring range: 0.32... 63 m3n/h... 3.5... 1400 m3 N /h Accuracy: ±2,5% of reading + 0,15% of full scale p max :

More information

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement Model LH-20 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater

More information

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement Model LH-20 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater

More information

FAS-W. Features. Applications. Automatic condensation hygrometer

FAS-W. Features. Applications. Automatic condensation hygrometer FAS-W HUMIDITY ANALYZER Automatic condensation hygrometer the «FAS-W» Moisture Analyzer automatic condensation hygrometer can measure both the volume fraction of moisture and the dew point temperature

More information

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Pro-V Multivariable Flowmeter Model M22 In-line Vortex Pro-V Multivariable Flowmeter Model M22 In-line Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,

More information

Micro Motion 3098 Gas Specific Gravity Meter

Micro Motion 3098 Gas Specific Gravity Meter Product Data Sheet PS-001188, Rev. B April 2009 Micro Motion 3098 Gas Specific Gravity Meter Micro Motion density and concentration meters are built to tackle the most demanding process and fiscal applications.

More information

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring. Product Data Sheet CODEL Continuous Emission Monitoring GCEM4100 Extractive Gas Analyser CO, CO2, NO, NO2, SO2, HCL, CH4 & H2O Hot extractive multi-channel gas analyser for continuous process and emissions

More information

HydroCOM: High energy savings and excellent controllability

HydroCOM: High energy savings and excellent controllability HydroCOM: High energy savings and excellent controllability Almost all applications require efficient capacity control systems Most of them simply waste energy, are slow and inaccurate. HydroCOM, however,

More information

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases P r o d u c t i n f o r m at i o n EuroFID Total Hydrocarbon Analyzer Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases Proven Analyzer Technology Measuring total

More information

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring.

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring. Product Data Sheet CODEL Continuous Emission Monitoring GCEM 40 Series Extractive Gas Analyser CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O Extractive low cost, low maintenance devices for continuous

More information

Non-intrusive Natural Gas Flow Measurement

Non-intrusive Natural Gas Flow Measurement Non-intrusive Natural Gas Flow Measurement Upstream Midstream Downstream - Gas at the Separator Outlet - Wellhead Gas Flow Measurement - Gas Injection n & Lift - Gas Treatmentent on - Compressor r Stations

More information

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres Drawing 1 VA Di ZG1 Ex-d Measured variables actual flow rate

More information

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars. Simply a question of better measurement SCHMIDT Flow Sensor SS 20.261 The cost-effective alternative in pressurised systems up to 10 bars. Compressed air technology Industrial processes A cost analysis

More information

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER THERMAL MASS FLOW METER s Series Thermal Mass Flow Meters provide accurate and reliable flow measurement for natural gas, compressed air, and other industrial gas applications. Natural Gas Compressed Air

More information

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring. Product Data Sheet CODEL Continuous Emission Monitoring GCEM4100 Extractive Gas Analyser CO, CO2, NO, NO2, SO2, HCL, CH4 & H2O Hot extractive multi-channel gas analyser for continuous process and emissions

More information

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements

More information

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE ATEX CHEMISTRY DIAPHRAGM PUMPS. ATEX VARIO CHEMISTRY DIAPHRAGM PUMPS. Chemistry diaphragm pumps, vacuum systems and gauges for use in

More information

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement Model LH-20 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater

More information

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries. VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet 34-VF-03-05 September 3rd, 2008 Specification The all-in-one solution The VERSAFLOW is the only vortex flowmeter with integrated pressure and

More information

Technical Data Sheet. OPTIMASS 7000 Custody Transfer Mass Flowmeter

Technical Data Sheet. OPTIMASS 7000 Custody Transfer Mass Flowmeter Technical Data Sheet KROHNE 12/2004 7.02516.21.00 CH/GR OPTIMASS 7000 Custody Transfer Mass Flowmeter with single straight measuring tube OIML R117 Pattern Approval Accuracy classes 0.3 / 0.5 / 1.0 / 1.5

More information

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in: XMO2 Panametrics Smart Oxygen Analyzer Applications An oxygen transmitter for use in: Inerting/blanketing liquid storage tanks Reactor feed gases Centrifuge gases Catalyst regeneration Solvent recovery

More information

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C) Product Data Sheet PDS 106-581.A01 March, 2004 Model 5081FG Two-Wire In Situ Oxygen Analyzer (550 to 1400 C) Intrinsically safe: - CENELEC EEx ia IIC - Class I Div. I Gr. B, C, D (pending) Operates at

More information

combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring

combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring Flue Gas Oxygen Genesis is a range of flue gas analyzers for measuring Oxygen

More information

Vortex Meters for Liquids, Gas, and Steam

Vortex Meters for Liquids, Gas, and Steam A Measuring Principle Comes of Age: Vortex Meters for Liquids, Gas, and Steam Dipl.-Hyd. Oliver Seifert, Product Management Vortex Meters at Flowtec AG, and Ellen-Christine Reiff, M.A., Editor s Office,

More information

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 VA 520 incl. temperature R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 R 1 1/4 (DN 32) DN 40 R 2 (DN 50) Intelligent solutions for ac- for compressed air and gases work according to the approved calorimetric

More information

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 VA 520 incl. temperature R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 R 1 1/4 (DN 32) DN 40 R 2 (DN 50) Intelligent solutions for ac- for compressed air and gases work according to the approved calorimetric

More information

Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing

Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing Vortex Flow Sensor VA Di Ex-d Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing Drawing 1 Measurable variables actual flow rate actual

More information

deltaflowc deltaflowc Venturi or Probe

deltaflowc deltaflowc Venturi or Probe deltaflowc Mass Flowmeter for Gases - Multivariable with ultra fast dp, p and T-sensors - Compact, accurate and user-friendly - Ideal for OEMs deltaflowc Venturi or Probe Precise mass flow metering deltaflowc

More information

combustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company

combustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring An Company Flue Gas Oxygen Genesis is a range of flue gas analyzers for measuring

More information

C-Flow Coriolis Mass Flow Meters

C-Flow Coriolis Mass Flow Meters Coriolis Mass Flow Meters Ready for Take Off The New Compact C-Flow Küppers Elektromechanik GmbH The C-Flow The C-Flow Coriolis Mass Meters consist of two components: KCE Transmitter KCM Transducer 2 KEM

More information

Features. Description

Features. Description Features Fast response flow meter ideal for inert gas and liquid mass flow measurement applications Smart electronics permit field adjustment of critical flow meter settings Field validation of flow meter

More information

Ultrasonic level transmitter and indicator

Ultrasonic level transmitter and indicator Ultrasonic level transmitter and indicator No contact with the product Compact design with polycarbonate housing (electronics and display). Remote display available on request Very good resistance in corrosive

More information

Autocalibration Systems For In Situ Oxygen Analyzers

Autocalibration Systems For In Situ Oxygen Analyzers Product Data Sheet PDS 106-340AC SPS 4000, IMPS 4000, and MPS 3000 January, 1999 Autocalibration Systems For In Situ Oxygen Analyzers Cost-effective autocalibration systems for installations ranging from

More information

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000 Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Automotive and avionics industry Industry (laboratory, workshop and production) Transmitter

More information

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling SERVOPRO Plasma The SERVOPRO Plasma is a Plasma Emission Detector based analyser designed to continuously measure Nitrogen in pure Argon for process and quality control in Argon production within Cryogenic

More information

FTC130 Transmitter. Operating Manual

FTC130 Transmitter. Operating Manual Seite 1 von 11 FTC130 Transmitter Fast Thermal Conductivity Analyzer Operating Manual 1.09KD180724CWI1V05 Messkonzept GmbH Seite 2 von 11 1. Intended Use... 3 2. Description... 4 3. Measuring gases and

More information

Visualize Nitrogen Gas Consumption

Visualize Nitrogen Gas Consumption Air Flow Monitor EWA2 SERIES Conforming to EMC Directive (all models) & Pressure Equipment Directive (AEWA2150/2200 only) Visualize Nitrogen Gas Consumption Small pipe size as Well as Air Consumption!

More information

EasyLine Continuous Gas Analyzers. So smart, they re simple

EasyLine Continuous Gas Analyzers. So smart, they re simple EasyLine Continuous Gas Analyzers So smart, they re simple Reliable Economic Powerful EasyLine is both a powerful and affordable line of instruments for the monitoring of gas concentrations in numerous

More information

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS Precise and Stable SF 6 Gas Analyzer Simultaneous measurement of humidity, SF 6 purity and SO 2 concentration Integrated gas recovery system with automatic pump back Fully automated SF 6 gas testing Fundamental

More information

Product information. Ultrasonic Gas Meter. Custody Transfer Measurement in Natural Gas Distribution

Product information. Ultrasonic Gas Meter. Custody Transfer Measurement in Natural Gas Distribution Product information FLOWSIC500 Ultrasonic Gas Meter Custody Transfer Measurement in Natural Gas Distribution FLOWSIC500 Ultrasonic Gas Meter Custody transfer measurement in natural gas distribution Product

More information

How to specify a product. Process Sensors and Mechanical Instruments

How to specify a product. Process Sensors and Mechanical Instruments How to specify a product Process Sensors and Mechanical Instruments Keep the overview. Here is some guideline information on how to specify our products. Intended as supplementary help to specification

More information

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000 Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Healthcare and avionics industry Industry (laboratory, workshop and production) Transmitter

More information

Product Information. Three in One: Gas Meter Tariff Device Volume Corrector. Ultrasonic Gas Meter ECOSONIC X12

Product Information. Three in One: Gas Meter Tariff Device Volume Corrector. Ultrasonic Gas Meter ECOSONIC X12 Product Information Three in One: Gas Meter Tariff Device Volume Corrector Ultrasonic Gas Meter ECOSONIC X12 ECOSONIC X12 Values you can count on The Application Fields The ultrasonic gas meters of the

More information

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide OSAT Series Intrinsically Safe Infrared Temperature Sensor Operator's Guide Issue L Jan 2017 Introduction OSAT Series intrinsically safe non-contact infrared temperature sensors measure the temperature

More information

Thermal Energy Flowmeter Model KEC. Application Range. Special Features

Thermal Energy Flowmeter Model KEC. Application Range. Special Features Thermal Energy Flowmeter for gases measuring monitoring analysing KEC O O Direct mass flow rate measurement of gases OMeasuring O accuracy: ± 0.3% of full scale ±1.5% of reading on request: ± 0.3% of full

More information

...makes sense! Combined CO 2 /O 2 analyzers. Monitor your process in real-time: OUR CER. BlueSens.com

...makes sense! Combined CO 2 /O 2 analyzers. Monitor your process in real-time: OUR CER. BlueSens.com ...makes sense! Combined CO 2 /O 2 analyzers Monitor your process in real-time: BlueSens.com OUR CER RQ ...makes sense! The BlueInOne sensor BlueSens is providing modern and inexpensive measuring solutions

More information

BSP Pressure Sensor Balluff GmbH, BA Marco Zorcic.

BSP Pressure Sensor Balluff GmbH, BA Marco Zorcic. 1 2 Standard Pressure Sensor with display Overview Pressure Range Relative nominal Overload Burst Permitted negative -1..2 bar 2 bar 4 bar 10 bar -1..10 bar 10 bar 20 bar 35 bar 0..2 bar 2 bar 4 bar 10

More information

780S Ultra High Purity Series

780S Ultra High Purity Series Smart Ultra High Purity Thermal Gas Mass Flow Meter Features Measures mass flow directly, no seperate temperature or pressure inputs required Field adjustment of critical flow meter settings via on-board

More information

deltaflowc deltaflowc Gas Massflowmeter Venturi- and Probe Type

deltaflowc deltaflowc Gas Massflowmeter Venturi- and Probe Type deltaflowc Mass Flowmeter for Gases - Multivariable with ultra fast dp-, p- and T-Sensors - Compact, accurate and user-friendly - Ideal for OEMs deltaflowc Gas Massflowmeter Venturi- and Probe Type Precise

More information

Gas Analysis Isn t Exactly Your Only Priority? Luckily For You, It s Ours. SIPROCESS GA700 effortless gas analytics from Siemens. siemens.

Gas Analysis Isn t Exactly Your Only Priority? Luckily For You, It s Ours. SIPROCESS GA700 effortless gas analytics from Siemens. siemens. Gas Analysis Isn t Exactly Your Only Priority? Luckily For You, It s Ours. SIPROCESS GA700 effortless gas analytics from Siemens. Easier Than Ever SIPROCESS GA700 The New Generation of Continuous Gas Analytics.

More information

GasSense NDIR User Manual

GasSense NDIR User Manual INDEX INDEX... 1 1. OVERVIEW... 2 2. TECHNICAL DATA... 3 3. SPECIFICATIONS... 4 4. PRODUCT DESCRIPTION... 5 4.1 Mechanical details... 5 4.2 Piping... 7 4.3 Connections... 7 5. INSTALLATION... 10 6. CALIBRATION

More information

Differential Pressure Transmiter

Differential Pressure Transmiter Differential Pressure Transmiter Description The is an economical alternative to established differential pressure transmitters. It combines state of the art electronics and a high performance sensor;

More information

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel KROHNE 04/2003 7.02445.71.00 GR 7000 Series OPTIMASS Mass Flowmeters with single straight measuring tube Titanium Hastelloy Stainless Steel One tube no limits No limits with tube material No limits with

More information

Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids

Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids No contact with the product Compact design with polycarbonate housing (electronics and display).

More information

Ultra High Purity Model 780S

Ultra High Purity Model 780S Smart Ultra High Purity Thermal Gas Mass Flow Meter Features Measures mass flow directly, no separate temperature or pressure inputs required Built-in flow conditioner which eliminates velocity-profile

More information

THERMAL MASS FLOW MEASUREMENT FOR GASES

THERMAL MASS FLOW MEASUREMENT FOR GASES THERMAL MASS MEASUREMENT FOR GASES Make the Wise Choice. Choose Sage Flow Meters. A Commitment to Higher Performance SAGE METERING is a manufacturer of high performance Thermal Mass Flow Meters which measure

More information

ERZ 2000-NG Flow Computer

ERZ 2000-NG Flow Computer ERZ 2000-NG Flow Computer With decades of natural gas measurement experience, RMG has developed the ERZ 2000-NG an approved and best-in-class gas flow measurement solution for all areas of gas volume conversion.

More information

SonoMeter 30 Energy Meters

SonoMeter 30 Energy Meters Data Sheet SonoMeter 30 Energy Meters Description The Danfoss SonoMeter 30 is a range of ultrasonic, compact energy meters intended for measuring energy consumption in heating and cooling applications

More information

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation High-precision Humidity Calibrator The role of humidity calibrations that are accurate, reproducible, and documentable is becoming more and more important. ISO quality guidelines and regulations according

More information

TransPort PT878GC Panametrics Portable Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

TransPort PT878GC Panametrics Portable Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features Applications The TransPort PT878GC clamp-on gas flowmeter is a complete ultrasonic flow metering system for measurement of most gases, including: Natural gas Compressed air Fuel gases Erosive gases Corrosive

More information

HYPOXIC AIR FIRE PREVENTION SYSTEM TECHNICAL SPECIFICATION

HYPOXIC AIR FIRE PREVENTION SYSTEM TECHNICAL SPECIFICATION HYPOXIC AIR FIRE PREVENTION SYSTEM TECHNICAL SPECIFICATION Introduction: Hypoxic Air Fire Prevention System is a revolutionary fire prevention technology. It has the unique ability to create a breathable

More information

Model 601CV. Mass Flow Controller. Product Features:

Model 601CV. Mass Flow Controller. Product Features: Model 601CV Mass Flow Controller Porter s Model 601CV Series II Mass Flow Controller (MFCs) is designed for precise control of virtually all conventional process gases. The MFC consists of a thermal mass

More information

Pressure measurement is a family affair

Pressure measurement is a family affair Get to know the team of specialists! Process Instrumentation Pressure measurement is a family affair Discover our P family. usa.siemens.com/pressure Whether it be hygienic requirements or rugged and harsh

More information

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass

More information

Programmable Submersible Level Transmitters

Programmable Submersible Level Transmitters Programmable Submersible Level Transmitters PTM/N/RS485 CUSTOMER BENEFITS High flexibility due to scalalbe pressure range Digital (RS485) and analogue (4-20mA) output signal in one sensor Available as

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 10 mm flush Shielded PUR cable for oil and gas sector Accessories BF 30 Mounting flange, 30 mm Technical Data specifications Switching function Normally closed (NC) Output type

More information

better measurement Simply a question of

better measurement Simply a question of Simply a question of better measurement SCHMIDT Flow Sensor SS 20.600 The powerful industrial professional for demanding applications involving air and gases. Industrial processes Pneumatic technology

More information

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

DM01. Please visit our website:  Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05 DM0 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing

More information

For the highest operational safety around the clock

For the highest operational safety around the clock Byworth Boilers Proline Promass 200 Coriolis flow measurement in efficient twowire technology for the chemical industry For the highest operational safety around the clock Efficient two-wire technology

More information

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions Flow Meter with multiple functions for gases and liquids M3 The M-series Flow Meter, with its versatile and user-friendly

More information

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

Test pumps. Pressure sources. Good reasons for proper and reliable calibration Test pumps Pressure is one of the most commonly measured quantities in engineering, which is why exact and reliable pressure measurement is especially important. However, the characteristics of the even

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter

ABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter ABB MEASUREMENT & ANALYTICS DATA SHEET WaterMaster FEW530 Electromagnetic water meter 2 WATE RMASTE R F E W 530 ELECT ROMAGNE TIC WATE R ME TE R DS/FE W530/FE T3 -E N RE V. A Measurement made easy Cost

More information

G4S G4A1KY RESIDENTIAL CONVERSION KIT LOW PRESSURE CONVERSION KIT MEDIUM PRESSURE CONVERSION KIT HIGH PRESSURE CONVERSION KIT ULTRASONIC GAS METER

G4S G4A1KY RESIDENTIAL CONVERSION KIT LOW PRESSURE CONVERSION KIT MEDIUM PRESSURE CONVERSION KIT HIGH PRESSURE CONVERSION KIT ULTRASONIC GAS METER Gas Meters content G4S G4A1KY RESIDENTIAL CONVERSION KIT LOW PRESSURE CONVERSION KIT MEDIUM PRESSURE CONVERSION KIT HIGH PRESSURE CONVERSION KIT ULTRASONIC GAS METER G4S G4S Residential Diaphragm Type

More information

TransPort PT878GC Panametrics Ultrasonic Portable Gas Flowmeter. GE Infrastructure Sensing. Features. Applications

TransPort PT878GC Panametrics Ultrasonic Portable Gas Flowmeter. GE Infrastructure Sensing. Features. Applications Applications The TransPort PT878GC clamp-on gas flowmeter is a complete ultrasonic flow metering system for measurement of most gases, including: Natural gas Compressed air Fuel gases Erosive gases Corrosive

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens AG 07 Overview Function U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/ Equipotential bonding Diaphragm The pressure

More information

KMT Waterjet Systems Inc.

KMT Waterjet Systems Inc. Advancing Waterjet Technology Worldwide Sales and Support Network Making Waterjet Systems Easier to Use, with Greater Reliability ISO 9001:2000 Certification; CSA and CE Certified Trained, Certified Technicians

More information

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor.  Type: ETd 04. class 0.05 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 100 mbar up to 0... 400 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing

More information

ABB MEASUREMENT & ANALYTICS. Continuous gas analyzers EL3060 The specialists for hazardous areas

ABB MEASUREMENT & ANALYTICS. Continuous gas analyzers EL3060 The specialists for hazardous areas ABB MEASUREMENT & ANALYTICS Continuous gas analyzers EL3060 The specialists for hazardous areas The specialists for hazardous areas ABB Analytical possesses decades of experience in the area of explosion

More information

ABB MEASUREMENT & ANALYTICS. Continuous gas analyzers EL3060 The specialists for hazardous areas

ABB MEASUREMENT & ANALYTICS. Continuous gas analyzers EL3060 The specialists for hazardous areas ABB MEASUREMENT & ANALYTICS Continuous gas analyzers EL3060 The specialists for hazardous areas The specialists for hazardous areas ABB Analytics possesses decades of experience in the area of explosion

More information

LT GasAnalyzer. LT GasAnalyzer Page 1 of 6

LT GasAnalyzer. LT GasAnalyzer Page 1 of 6 LT GasAnalyzer LT GasAnalyzer Page 1 of 6 LT GasAnalyzer Disturbances in the protective gas supply can cause production losses or affect product quality. In the worst case, it even can endanger life and

More information

ELECTRIC ACTUATORS for continuous underwater use

ELECTRIC ACTUATORS for continuous underwater use ELECTRIC ACTUATORS for continuous underwater use The SA multi-turn actuator for continuous underwater use by AUMA opens new applications for electric actuators for water supply, in hydropower plants and

More information

PRODUCT INFORMATION. FLOWSIC100 Flare RELIABLE GAS FLOW MEASUREMENT IN FLARE GAS APPLICATIONS. Mass flow measuring devices

PRODUCT INFORMATION. FLOWSIC100 Flare RELIABLE GAS FLOW MEASUREMENT IN FLARE GAS APPLICATIONS. Mass flow measuring devices U W100 lare G W U G ass flow measuring devices U Y V U X W100. he measurement of flare gas in the chemical and petrochemical industry is widely considered to be the leading discipline in gas flow measurement.

More information

Mass Flow Meter (MFM) for Gases

Mass Flow Meter (MFM) for Gases 873 Mass Flow Meter (MFM) for Gases Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy Short response time Compact design and digital

More information

TEK-THERMAL 1700B. Thermal Mass Flowmeter. FLOW. Technology Solutions

TEK-THERMAL 1700B. Thermal Mass Flowmeter.   FLOW. Technology Solutions Technology Solutions TEK-THERMAL 1700B Thermal Mass Flowmeter FLOW www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Thermal 1700B Thermal Mass Flowmeters,

More information

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6 P9000 High accuracy through digital compensation High thermal stability Rugged stainless steel construction Ideal for test stands High burst pressure limit DESCRIPTION The P9000 Series is a range of advanced,

More information

TF- & DM-Series. Turbineflowmeter

TF- & DM-Series. Turbineflowmeter Turbineflowmeter .. are the ideal solution for measuring applications in liquids when high accuracy, very fast response times, compact design, high reliability are also required in continuous operation

More information

AUTOMATIC HOSE TEST UNIT, TYPE SPU

AUTOMATIC HOSE TEST UNIT, TYPE SPU VALVES AND FITTINGS UP TO 14,000 BAR TEST AND CONTROL EQUIPMENT H IGH PRESSURE TECHNOLOGY AUTOMATIC HOSE TEST UNIT, TYPE SPU Pressure range from 1 up to 10,000 bar User-friendly touch panel operation HIGH-PRESSURE

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and

More information

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter Overview C % ppm 4~20mA Analog Output ppb Power Supply 100~240 VAC mg/l Dimensions 96 x 96 x 132mm RS-485 Digital Output (for DC-5310-RS only)

More information

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing Ø

More information

Applications. Features AWWA ULTRASONIC WATER METER

Applications. Features AWWA ULTRASONIC WATER METER MEASURE TODAY. ENSURE TOMORROW wprime Series 280W-D Applications Revenue metering Residential submetering Commercial buildings Leakage detection AMR / AMI and billing Drive-by metering Features Residential

More information