Roxar 2 System Mechanical Retrieval Tool

Size: px
Start display at page:

Download "Roxar 2 System Mechanical Retrieval Tool"

Transcription

1 Roxar Mechanical Retrieval Tool FA-T226-A Product Data Sheet Roxar 2 System Mechanical Retrieval Tool The Roxar 2 Mechanical Retrieval Tool is a high quality tool for installation and retrieval of probes and coupons in standard 2 mechanical access systems under full operational pressure. The tool is compatible with access systems provided by most common vendors on the market. The tool works on a telescopic principle, comprising a fixed inner barrel and an outer barrel that moves during operation. Probes/coupon holders are installed or retrieved by pulling or pushing the outer barrel, assuming a balanced pressure within the tool. Observe that operating any telescope type mechanical retrieval tool is a potentially safety critical operation. If pressure is not balanced within the mechanical retrieval tool under operation, the pressure difference may push the outer barrel with uncontrolled force and speed, and in consequence, hit and injure personnel and equipment. It is therefore required that a Back Pressure Pump is always used with Roxar 2 Mechanical Retrieval Tool when operating on pressurized lines or vessels 1). From a safety perspective, Roxar 2 Mechanical Retrieval Tool is designed for use with a double block and bleed valve, to ensure double pressure barriers for the valve 2) Roxar Service valve is described in separate data sheet. Roxar 2 Mechanical Retrieval Tool comes as a kit including retrieval tool (complete with pressure gauge and bleed valve), back pressure pump, and spare parts - in a convenient transport case. Safety Note: High pressure retrieval tools must only be operated by trained personnel and according to controlled operating procedures. 1) Observe that Roxar recommend Hydraulic Access and Retrieval Tool system as a safer (no external moving parts) and more convenient (less operational space required) alternative. Mechanical system may be converted to hydraulic system - see separate data sheet. 1

2 Roxar Mechanical Retrieval Tool Mechanical Retrieval Tool Dimensional Data Roxar Mechanical Retrieval Tool with Double Block and Bleed Service Valve Maximum Device Length (mm/ ) 150/6 240/ / / / /46 Mechanical Retrieval Tool length, retracted, incl. service valve (mm/ ) Mechanical Retrieval Tool length, extended, incl. service valve (mm/ ) Mech. Retrieval Tool weight (kg) - excl. service valve 894/ / / / / / / / / / / /

3 Roxar Mechanical Retrieval Tool Back pressure pump for Mechanical Retrieval Tool A back pressure pump shall always be used to raise the pressure inside the retrieval tool to be slightly higher than the pipe pressure. This will ensure that the outer barrel of the tool will not accidentally move uncontrolled during probe/coupon removal. Back pressure pump for Mechanical Retrieval Tool Roxar Mechanical Retrieval Tool with service valve and transport case Ordering Information Roxar Mechanical Retrieval Tool can be purchased a complete kit (including accessories and service valve) or as a retrieval tool only. Please refer to data Sheet for Roxar Service Valve for service valves. 3

4 Roxar Mechanical Retrieval Tool Model Selector - Roxar Mechanical Retrieval Tool Model MRT Product Description Mechanical Retrieval Tool Pressure Rating 1 Max 6,000 psi Design Pressure L01 L02 L03 L04 L05 L06 Tool Length Maximum device Length:150 mm Maximum device Length: 240 mm Maximum device Length: 425 mm Maximum device Length: 640 mm Maximum device Length: 920 mm Maximum device Length: 1170 mm Tool Material (Main Components) 2G6A Alloy 17-4PH (UNS S17400) Cylinder, ASTM A182 F22 Hammer Nut EN NACE MR0175 9X9X 1 Project Specific Material Operating mode and conditions 01 Standard Viton O-rings 02 Rapid Gas Decompression FR 25/90 O-rings 03 Rapid Gas Decompression and/or 100 % Methanol Elast-O-Lion 101 O-rings M N 1 ZZ TG XX 1 Z X Approvals ROXAR Standard (no 3rd party approval) PED Compliant Tool Tag Plates No Tag Plates Standard Tag Plates Project Specific Tag Plates Factory Options Standard product ETO product Certificate, Tests, Calibrations and Services (Not Required, all are optional) Other Testing TX 1 Project-specific testing 1 Not Available with factory Option Z 4

5 Roxar Mechanical Retrieval Tool Model Selector - Pump for Mechanical Retrieval Tool Model PUMP-RT M3 M Product Description Pump for Retrieval Tool System Pump Application and Operation Manual (back filling only) for MRT Approvals ROXAR Standard (no 3rd party approval) Z 1 Pump ATEX - Equipment Category 2 (Zone 1) ZZ TG XX 1 Z X Tag Plates No Tag Plates Standard Tag Plates Project Specific Tag Plates Factory Options Standard product ETO product Certificate, Tests, Calibrations and Services (Not Required, all are optional) Special Tests and Certificates Other Testing TX 1 Project specific testing 1 Not Available with factory Option Z Head Office Roxar products: Tel: info.roxar@emerson.com CIS Tel: Europe Tel: North America Tel: Middle East Tel: Asia Pacific Tel: Australia Tel: Latin America Tel: Emerson Electric Co. All rights reserved. The Emerson logo is a trademark and service mark of Emerson Electric Co. Brand name is a mark of one of the Emerson Process Management family of companies. All other marks are the property of their respective owners. The contents of this publication are presented for information purposes only, and while effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice. The Roxar products are protected by patents. See for details. 5

Roxar 2 System Mechanical Retrieval Tool

Roxar 2 System Mechanical Retrieval Tool FA-T226-A Product Data Sheet Roxar 2 System Mechanical Retrieval Tool The Roxar 2 Mechanical Retrieval Tool is a high quality tool for installation and retrieval of probes and coupons in standard 2 mechanical

More information

1805 Series Relief Valves

1805 Series Relief Valves Instruction Manual Form 1211 1805 Series October 2011 1805 Series Relief Valves! WARNING Failure to follow these instructions or to properly install and maintain this equipment could result in an explosion

More information

1305 Series Pressure Reducing Regulators

1305 Series Pressure Reducing Regulators Instruction Manual Form 1095 1305 Series October 2009 1305 Series Pressure Reducing Regulators! Warning Fisher regulators must be installed, operated, and maintained in accordance with federal, state,

More information

1805 Series Relief Valves

1805 Series Relief Valves October 2011 1805 Series Relief Valves P1026 1805G Type 1805-2 Type 1805-4 Figure 1. Typical 1805 Relief Valves Introduction The 1805 Series relief valves are designed for use in farm tap applications

More information

64 Series Pressure Reducing Regulators

64 Series Pressure Reducing Regulators Instruction Manual Form 1245 64 Series March 2006 64 Series Pressure Reducing Regulators W1943 Figure 1. 64 Series Regulator Introduction Scope of Manual This manual provides instructions for the installation,

More information

Damcos PHP Portable hand pump unit 5 l. Product Data Sheet September 2014 SD E04

Damcos PHP Portable hand pump unit 5 l. Product Data Sheet September 2014 SD E04 Damcos PHP 25-05 Portable hand pump unit 5 l Product Data Sheet September 2014 SD 6601-2E04 TM Damcos PHP 25-05 September 2014 General description Double-acting portable hand pump incl. 5 l. reservoir

More information

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012 Installation Guide English September 2012 299H Series Introduction This Installation Guide provides instructions for installation, startup, and adjustment of 299H Series regulators. To receive a copy of

More information

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator January 2009 Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator Introduction The Type 310A pilot-operated high-pressure regulator (Figure 1) is used where high capacity

More information

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures Operations & Service Manual TESCOM 50-4X Series Safety, Installation & Start-Up Procedures Do not attempt to select, install, use or maintain this product until you have read and fully understood this

More information

T208VR Series Tank Blanketing Vacuum Regulator

T208VR Series Tank Blanketing Vacuum Regulator February 2014 T208VR Series Tank Blanketing Vacuum Regulator Figure 1. Typical T208VR Series Vacuum Regulator Introduction The T208VR Series direct-operated vacuum regulators are used where a decrease

More information

Product Data Sheet L-TRDD-D Rev. 1 November Shafer L-Series Linear Valve Actuators Thrust Ratings and Dimensional Data

Product Data Sheet L-TRDD-D Rev. 1 November Shafer L-Series Linear Valve Actuators Thrust Ratings and Dimensional Data Product Data Sheet L-TRDD-D-11097 Rev. 1 November 2017 Shafer L-Series Linear Valve Actuators Thrust Ratings and Dimensional Data Product Data Sheet L-TRDD-D-11097 Rev. 1 Shafer L-Series November 2017

More information

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection Instruction Manual D100343X012 Type 1367 November 2017 Type 1367 High-Pressure Instrument Supply System with Overpressure Protection TYPE 252 FILTER 2ND-STAGE TYPE 67CF FILTER-STYLE REGULATOR INLET TYPE

More information

Type EZH Relief or Backpressure Regulator

Type EZH Relief or Backpressure Regulator Bulletin 71.4 D103574X012 Type EZH December 2017 Type EZH Relief or Backpressure Regulator P1668 Figure 1. Type EZH Relief Valve or Backpressure Regulator Features Bubble Tight Shutoff A knife-edged metal

More information

Type R622 Pressure Reducing Regulator

Type R622 Pressure Reducing Regulator Type R622 Pressure Reducing Regulator June 2010 Compact Design Protective Inlet Screen High Capacity Internal Relief Light Weight W8806 Inlet and Outlet Pressure Gauge Taps Figure 1. Type R622 Pressure

More information

COSASCO 3600 PSI SINGLE ISOLATION SERVICE VALVE (FR) MAINTENANCE

COSASCO 3600 PSI SINGLE ISOLATION SERVICE VALVE (FR) MAINTENANCE COSASCO 3600 PSI SINGLE ISOLATION SERVICE VALVE (FR) MAINTENANCE Rohrback Cosasco Systems, Inc. 11841 E. Smith Avenue Santa Fe Springs, CA 90670 Tel: (562) 949-0123 (800) 635-6898 Fax: (562) 949-3065 www.cosasco.com

More information

R133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid

R133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid R133 Brass high pressure regulator, suitable for compressed air, gas and liquid HELYON 5 Chemin du Jubin 6957 DARDILLY Tél. +33 () 7 5 16 7 - Fax +33 () 7 5 16 71 FEATURES High pressure regulator for cylinder

More information

Y692VB Series Vacuum Breaker

Y692VB Series Vacuum Breaker Y692VB Series Vacuum Breaker Bulletin 71.3:Y692VB June 2009 W7429 Figure 1. Type Y692VB Vacuum Breaker Introduction The Y692VB Series direct-operated vacuum breakers are used for the precise control of

More information

1301 Series High-Pressure Regulators

1301 Series High-Pressure Regulators Instruction Manual Form 1111 Types 1301F and 1301G March 2013 1301 Series High-Pressure Regulators! WARNING Failure to follow these instructions or to properly install and maintain this equipment could

More information

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators July 2010 W3716 W3507 Type 1808 Type 1808A Figure 1. Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

More information

Micro Motion 7812 Fiscal Gas Density Meter

Micro Motion 7812 Fiscal Gas Density Meter Product Data Sheet PS-001162, Rev. B April 2009 Micro Motion 7812 Fiscal Gas Density Meter Micro Motion density and concentration meters are built to tackle the most demanding process and fiscal applications.

More information

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C) Product Data Sheet PDS 106-581.A01 September, 2007 Model 5081FG Two-Wire In Situ Oxygen Analyzer (550 to 1400 C) Intrinsically safe: ATEX, Zone 1, EEx ia IIC T4 Class I, Div. I, Gr. A, B, C, D T4 Operates

More information

Types ACE95 and ACE95Sr Tank Blanketing Valves

Types ACE95 and ACE95Sr Tank Blanketing Valves Types ACE95 and ACE95Sr Tank Blanketing Valves Bulletin 74.1:ACE95 May 2010 W9133 W8155 Figure 1. Type ACE95 Tank Blanketing Valve Figure 2. Type ACE95Sr Tank Blanketing Valve Features Fully Balanced Pilot

More information

RELIEF VALVES. V Series. Process Management TM. Type V/20-2. Type V/50. Type V/60

RELIEF VALVES. V Series. Process Management TM. Type V/20-2. Type V/50. Type V/60 RELIEF VALVES V Series Type V/2-2 Type V/5 Type V/6 Process Management TM V/5 and V/6 Series Spring-Loaded Relief Valves The spring-loaded relief valves are designed to keep line pressure below preset

More information

Shafer Gas-Hydraulic Tanks Replacing Hydraulic Fluid Procedure on an Existing Actuator

Shafer Gas-Hydraulic Tanks Replacing Hydraulic Fluid Procedure on an Existing Actuator MIS L10: Replacing Hydraulic Fluid Shafer Gas-Hydraulic Tanks Replacing Hydraulic Fluid Procedure on an Existing Actuator www.shafervalve.com The purpose of this procedure is to guide the operation of

More information

EL-O-Matic E and P Series Pneumatic Actuator SIL Safety Manual

EL-O-Matic E and P Series Pneumatic Actuator SIL Safety Manual SIL Safety Manual DOC.SILM.EEP.EN Rev. 0 April 2017 EL-O-Matic E and P Series Pneumatic Actuator SIL Safety Manual schaal 1:1 EL Matic TM EL-O-Matic E and P Series DOC.SILM.EEP.EN Rev. 0 Table of Contents

More information

Types ACE95 and ACE95Sr Tank Blanketing Valves

Types ACE95 and ACE95Sr Tank Blanketing Valves August 2013 Types ACE95 and ACE95Sr Tank Blanketing Valves W9133 W8155 Figure 1. Type ACE95 Tank Blanketing Valve Figure 2. Type ACE95Sr Tank Blanketing Valve Features Fully Balanced Pilot Design Reduces

More information

Quick Start Guide LIQ-QSG-499ACL-03, Rev I July Rosemount 499ACL-03. Monochloramine Sensor

Quick Start Guide LIQ-QSG-499ACL-03, Rev I July Rosemount 499ACL-03. Monochloramine Sensor Quick Start Guide LIQ-QSG-499ACL-03, Rev I July 2017 Rosemount 499ACL-03 Monochloramine Sensor Safety information CAUTION! SENSOR/PROCESS APPLICATION COMPATIBILITY The wetted sensor material may not be

More information

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C) Product Data Sheet PDS 106-581.A01 March, 2004 Model 5081FG Two-Wire In Situ Oxygen Analyzer (550 to 1400 C) Intrinsically safe: - CENELEC EEx ia IIC - Class I Div. I Gr. B, C, D (pending) Operates at

More information

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators 61 Series Pilots for Pilot-Operated Pressure Reducing Regulators June 2011 Introduction 61 Series pilots are used with Types 1098-EGR and EZL pressure reducing regulators. These pilots can also be integrally

More information

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002 Installation Guide English May 2002 Type ACE97 Introduction This installation guide provides instructions for installation, startup, and adjustment. To receive a copy of the instruction manual, contact

More information

Fisher L2sj Low Emission Liquid Level Controller

Fisher L2sj Low Emission Liquid Level Controller L2sj Controller Product Bulletin Fisher L2sj Low Emission Liquid Level Controller The rugged Fisher L2sj low emission liquid level controller uses a displacer type sensor to detect liquid level. This controller

More information

MODEL CALIBRATION GAS DELIVERY SYSTEM

MODEL CALIBRATION GAS DELIVERY SYSTEM MODEL 1200-26 CALIBRATION GAS DELIVERY SYSTEM Sierra Monitor Corporation 1991 Tarob Court, Milpitas, CA 95035 (408) 262-6611 MODEL 1200-26 CALIBRATION GAS DELIVERY SYSTEM APPLICABILITY & EFFECTIVITY This

More information

Type PRX/120, PRX/125, PRX-AP/120, PRX-AP/125, PRX/181, PRX/182, PRX/131 and PRX-AP/131 Pilots

Type PRX/120, PRX/125, PRX-AP/120, PRX-AP/125, PRX/181, PRX/182, PRX/131 and PRX-AP/131 Pilots Instruction Manual 0006EN-PRX-IM PRX Series July 2008 - Rev. 00 Type PRX/120, PRX/125, PRX-P/120, PRX-P/125, PRX/1, PRX/2, PRX/131 and PRX-P/131 Pilots summary Introduction... 1 Characteristics... 1 Labelling...

More information

Fisher Lever-Lock Handlever Actuators for POSI-SEAL A81 Rotary Valves

Fisher Lever-Lock Handlever Actuators for POSI-SEAL A81 Rotary Valves Instruction Manual D103319X012 Lever-Lock Handlever Actuator Fisher Lever-Lock Handlever Actuators for POSI-SEAL A81 Rotary Valves Contents Introduction................................. 1 Scope of Manual.........................

More information

Un-Pressurized Orefice Fittings FIO EZ. Parts List and Operation Instructions TECHNICAL MANUAL. Dn 2-6 Class Lbs

Un-Pressurized Orefice Fittings FIO EZ. Parts List and Operation Instructions TECHNICAL MANUAL. Dn 2-6 Class Lbs Un-Pressurized Orefice Fittings FIO EZ Parts List and Operation Instructions TECHNICAL MANUAL Dn 2-6 Class 150-600 Lbs US US 2 FIO EZ - MT 108-US - 05-2016 FIO EZ Important Instructions US Pietro Fiorentini

More information

Autocalibration Systems for In Situ Oxygen Analyzers

Autocalibration Systems for In Situ Oxygen Analyzers Product Data Sheet PDS 106-340AC.A01 February, 2006 SPS 4001B, IMPS 4000 and MPS 3000 Autocalibration Systems for In Situ Oxygen Analyzers Cost-effective autocalibration systems for installations ranging

More information

Type 1190 Low-Pressure Gas Blanketing Regulator

Type 1190 Low-Pressure Gas Blanketing Regulator April 202 Type 90 Low-Pressure Gas Blanketing Regulator W7428 Figure. Type 90 Low-Pressure Gas Blanketing Regulator Introduction The Type 90 low-pressure gas blanketing regulator is used for extremely

More information

Modulating liquid level regulators, servo-controlled PMFL / PMFH and SV

Modulating liquid level regulators, servo-controlled PMFL / PMFH and SV MAKING MODERN LIVING POSSIBLE Technical brochure Modulating liquid level regulators, servo-controlled / PMFH and SV For modulating liquid level control in refrigeration, freezing and air conditioning plant,

More information

Anchor Load Cells. Among the different types that are used as anchor load cells

Anchor Load Cells. Among the different types that are used as anchor load cells Chapter: 3.1 Anchor Load Cells Page No.: 1 Number of Pages: 1 In rock and base engineering anchors are applied as construction element. They stabilise the rock by absorbing axial load and shear forces.

More information

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L Calibration Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L WIKA data sheet CT 91.05 for further approvals see page 2 Applications Calibration service companies and service industry Calibrations

More information

Shafer RV-Series Rotary Vane Valve Actuators

Shafer RV-Series Rotary Vane Valve Actuators Shafer RV-Series Rotary Vane Valve Actuators Product Data Sheet RV-ASDD-D-3-06-09 Rev. 1 November 2017 U.S. Customary Units Dimension: inches (in) Torque: Inch Pounds (in-lbs) Pressure: Pounds Per Square

More information

DANFLO Control Valves 400 Series Model 20

DANFLO Control Valves 400 Series Model 20 DANFLO Control Valves 400 Series Model 20 Back Pressure/Pressure Relief The DANFLO Model 20 is a pilot operated valve suitable for use in gas or liquid facilities and requires no outside power for operation.

More information

Gas powered stop valves, type GPLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Gas powered stop valves, type GPLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet Gas powered stop valves, type GPLX 80-150 REFRIGERATION AND AIR CONDITIONING Technical leaflet Technical leaflet Gas powered stop valves, type GPLX 80-150 Contents Page Introduction........................................................................................3

More information

SLAM-SHUT VALVES. Type BM5. Process Management TM

SLAM-SHUT VALVES. Type BM5. Process Management TM SLAM-SHUT VALVES Type BM5 Process Management TM BM5 Slam-Shut Valves Slam-shut valves BM5 series slam-shut valve is an automatic shut-off appliance suitable for installation as safety device in regulating

More information

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide Pilot HON 62 Entwurf Product information serving the gas industry worldwide Pilot HON 62 Application, characteristics Application Pilot for the gas pressure regulator HON 02 Pilot for outlet pressure control

More information

R300 HELYON. Brass high pressure regulator, for compressed air, gas and liquids

R300 HELYON. Brass high pressure regulator, for compressed air, gas and liquids HELYON 5 Chemin du Jubin 69570 DARDILLY Tél. +33 (0)4 72 52 16 70 - Fax +33 (0)4 72 52 16 71 R300 Brass high pressure regulator, for compressed air, gas and liquids FEATURES Pressure regulator for inlet

More information

Leak free Pipe Rupture Valve for Excavators

Leak free Pipe Rupture Valve for Excavators Leak free Pipe Rupture Valve for xcavators Series motion and progress Reference: 3 P 9575 1/11.6 Classification: 43.325.355...325.35 1/17 Contents Page 1 General description................................................................

More information

instruction manual highpressure handpump manual

instruction manual highpressure handpump manual instruction manual highpressure handpump manual Introduction The FX pump is designed, manufactured and tested by FX Airguns AB in Sweden. There are two patented systems. The first of them is the 3 stage

More information

Pressure-limiting valve and pre-load valve type MVG, MVE and MVP

Pressure-limiting valve and pre-load valve type MVG, MVE and MVP Pressure-limiting valve and pre-load valve type MVG, MVE and MVP Product documentation Directly controlled Operating pressure pmax: Flow rate Qmax: 700 bar 8 lpm D 3726 02-2016-1.3 by HAWE Hydraulik SE.

More information

Fisher Lever Lock Handlever Actuators for POSI SEAL A81 Rotary Valves

Fisher Lever Lock Handlever Actuators for POSI SEAL A81 Rotary Valves Instruction Manual Lever-Lock Handlever Actuator Fisher Lever Lock Handlever Actuators for POSI SEAL A81 Rotary Valves Contents Introduction... 1 Scope of Manual... 1 Description... 1 Specifications...

More information

Types ACE95 and ACE95Sr Tank Blanketing Valves

Types ACE95 and ACE95Sr Tank Blanketing Valves October 2014 Types ACE95 and ACE95Sr Tank Blanketing Valves W9133 W8155 Figure 1. Type ACE95 Tank Blanketing Valve Figure 2. Type ACE95Sr Tank Blanketing Valve Features Fully Balanced Pilot Design Reduces

More information

Liquid level regulating valves Types PMFL / PMFH and SV

Liquid level regulating valves Types PMFL / PMFH and SV Data sheet Liquid level regulating valves Types / PMFH and SV For modulating liquid level control in refrigeration, freezing and air conditioning plant, a system comprising a liquid level regulating valve

More information

Techcon Systems TS1254 Pressure Pot

Techcon Systems TS1254 Pressure Pot Techcon Systems TS1254 Pressure Pot User Guide Copyright OK International, Inc. TABLE OF CONTENT 1. SAFETY. 3 1.1 Intended Use 3 1.2 Safety Precaution 3 2. FEATURES. 5 3. SPECIFICATIONS 4 4. INSTALLATION

More information

Types 627W and 627WH Direct-Operated Pressure Reducing Liquid Regulators

Types 627W and 627WH Direct-Operated Pressure Reducing Liquid Regulators Types 627W and 627WH Direct-Operated Pressure Reducing Liquid Regulators Introduction The Types 627W and 627WH are direct-operated pressure reducing regulators for liquid service. They are available in

More information

Certified Accuracy. Ring Force Gauge. Models and Capacities Available. Design and Principle of Operation

Certified Accuracy. Ring Force Gauge. Models and Capacities Available. Design and Principle of Operation Certified Accuracy Ring Force Gauge The accurate measurement of mechanical forces is required in hundreds of applications from a simple weighing procedure to the calibration of testing machines and load

More information

SPECIFICATION // DATA SHEET WATER DRAIN VALVE AM SENSORS LTD AMS-S-084/DS/ (ISSUE 1)

SPECIFICATION // DATA SHEET WATER DRAIN VALVE AM SENSORS LTD AMS-S-084/DS/ (ISSUE 1) SPECIFICATION // DATA SHEET WATER DRAIN VALVE 1 Introduction The Water Drain Valve was developed for a major oil company to detect the presence of fuel when discharging water through the drain line of

More information

LV LOADER DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE

LV LOADER DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE LV LOADER DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE SPECIFICATIONS: 10 gpm (38 lpm) Nominal Capacity. Rated up to 4000 psi (275 bar). Port Sizes-Inlet/Outlet #8SAE (3/4-16). Work Ports #8SAE

More information

Free Chlorine Sensor For additional information, please visit our website at

Free Chlorine Sensor For additional information, please visit our website at Instruction Manual 499ACL01 LIQ_MAN_ABR_499ACL01 April 2014 Free Chlorine Sensor For additional information, please visit our website at www.rosemountanalytical.com. CAUTION Sensor/Process Application

More information

RESIDENTIAL REGULATORS

RESIDENTIAL REGULATORS RESIDENTIAL REGULATORS Type B NG Process Management TM B NG Regulators Description! BODY RESISTANT TO HIGHER PRESSURES Various Springs Adaptable to various fluids (Natural Gas, LPG, Manufactured Gas, etc.)!

More information

Installation, Operation, & Maintenance Manual NX Seal Cooler

Installation, Operation, & Maintenance Manual NX Seal Cooler Installation, Operation, & Maintenance Manual NX Seal Cooler 1 1. INTRODUCTION 1.1 About this Manual This manual is intended to ensure a safe installation and operation of the NX sealcooler. All involved

More information

SIKA Ba_ODWT15_en 05/2018. Operating manual for oil deadweight tester 0.015% accuracy ODWT15

SIKA Ba_ODWT15_en 05/2018. Operating manual for oil deadweight tester 0.015% accuracy ODWT15 SIKA Ba_ODWT15_en 05/2018 Operating manual for oil deadweight tester 0.015% accuracy ODWT15 Table of Contents 1 introduction...1 1.1 general product description... 1 1.2 operating principle... 1 2 general

More information

Pressure Sensing Valve - Model 4023

Pressure Sensing Valve - Model 4023 Pressure Sensing Valve - Model 4023 Overview AMOT Model 4023 can be used as a 2 or 3-way capacity, pressure sensing valve. This valve is ideal for applications that require compressor suction and discharge

More information

Dissolved Oxygen Sensor

Dissolved Oxygen Sensor Instruction Manual 499ADO and 499ADO-VP LIQ_MAN_ABR_499ADO May 2014 Dissolved Oxygen Sensor CAUTION For additional information, please visit our website at www.rosemountanalytical.com SENSOR/PROCESS APPLICATION

More information

MUELLER. Mega-Lite Drilling Machine. Reliable Connections. table of contents PAGE. Equipment 2. Operating Instructions 3-4. Parts Information 5

MUELLER. Mega-Lite Drilling Machine. Reliable Connections. table of contents PAGE. Equipment 2. Operating Instructions 3-4. Parts Information 5 operating Instructions manual MUELLER Mega-Lite Drilling Machine table of contents PAGE Equipment 2 Operating Instructions 3-4 Parts Information 5 Travel Charts 6-11! WARNING: 1. Read and follow instructions

More information

1.0 - OPENING AND CLOSING THE DOOR

1.0 - OPENING AND CLOSING THE DOOR The purpose of this manual is to provide the user with instructions on how to safely open and close, how to conduct routine maintenance, and how to install the PEI TWINLOCK Closure on a pressure vessel.

More information

Mechanical Pressure Measurement

Mechanical Pressure Measurement Mechanical Pressure Measurement Differential Pressure Gauges Model GDP, Universal Version, with Diaphragm Element High Overpressure Safety PN 40, 100, 250 or 400 Applications Differential pressure measurement

More information

Proportional Relief Valves

Proportional Relief Valves www.swagelok.com Proportional Relief Valves R Series Liquid or gas service Set pressures from 10 to 6000 psig (0.68 to 413 bar) 1/4 and 1/2 in. and 6 to 12 mm end connections 2 Proportional Relief Valves

More information

Type Y692 Gas Blanketing Regulator System

Type Y692 Gas Blanketing Regulator System Bulletin 7:Y69 Type Y69 Gas Blanketing Regulator System November 14 W930-1 Figure 1. Type Y69 Low-Pressure Gas Blanketing Regulator Introduction An Accu-Pressure Gas Blanketing Regulator System reduces

More information

INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Model Sanitary Vent SECTION I

INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Model Sanitary Vent SECTION I INSTALLATION, OPERATION AND MAINTENANCE MANUAL Model 1100 Sanitary Vent IOM-1100 03-17 ISO Registered Company SECTION I I. DESCRIPTION AND SCOPE The Model 1100 is a stainless steel sanitary vent designed

More information

Hydraulic Accumulators with Back-Up Nitrogen Bottles

Hydraulic Accumulators with Back-Up Nitrogen Bottles Hydraulic Accumulators with Back-Up Nitrogen Bottles 1. GENERAL To complete the accumulator range, HYDAC provides a variety of useful accessory products. They guarantee correct installation and optimum

More information

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot. Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com P5513 Pneumatic Comparison Test Pump Users Manual PN 3963372 November 2010 2010 Fluke Corporation. All

More information

Common Discrepancies Uncovered on ADCI Diving Contractor & Training Program Audits

Common Discrepancies Uncovered on ADCI Diving Contractor & Training Program Audits Common Discrepancies Uncovered on ADCI Diving Contractor & Training Program Audits Ways to Set Your Company or School Up For Success on ADCI Audits and Reduce Costs In most instances, all discrepancies

More information

Type ACE95jr Tank Blanketing Valve

Type ACE95jr Tank Blanketing Valve Type ACE95jr Tank Blanketing Valve Features Fully Balanced Plug Design Reduces Inlet Pressure Sensitivity Bulletin 74.1:ACE95JR May 2010 Stainless Steel Construction Available High Sensitivity Self-Contained

More information

Valve test benches. Systems overview

Valve test benches. Systems overview Valve test benches Systems overview About us In the past few years WIKA has successfully integrated renowned manufacturers of calibration equipment into the group. With these established brands within

More information

SERVICE MANUAL. Technical Bulletin No GEOPROBE GH40 HYDRAULIC HAMMER. PREPARED: February, REVISED: April, 2002 A DIVISION OF KEJR, INC.

SERVICE MANUAL. Technical Bulletin No GEOPROBE GH40 HYDRAULIC HAMMER. PREPARED: February, REVISED: April, 2002 A DIVISION OF KEJR, INC. This document describes charging the GH40 Hydraulic Hammer with nitrogen gas. Text and illustrations were taken directly from the service manual shown below. GEOPROBE GH40 HYDRAULIC HAMMER SERVICE MANUAL

More information

DANFLO Liquid Surge Relief Valve

DANFLO Liquid Surge Relief Valve DANFLO Liquid Surge Relief Valve DANFLO Surge Relief Valves DANFLO Surge Relief Valves are engineered to track unabated surge-wave pressure transients-open quickly, then closes without slamming shut. The

More information

COSASCO 6000 PSI SINGLE ISOLATION SERVICE VALVE (FR) MAINTENANCE

COSASCO 6000 PSI SINGLE ISOLATION SERVICE VALVE (FR) MAINTENANCE COSASCO 6000 PSI SINGLE ISOLATION SERVICE VALVE (FR) MAINTENANCE 11841 Smith Avenue Santa Fe Springs, CA 90670 Tel: (562) 949-0123 (800) 635-6898 Fax: (562) 949-3065 www.cosasco.com Page: 2 of 26 Revision

More information

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE INSTALLATION, OPERATION & MAINTENANCE MANUAL INTERFACE DEVICES, INC. 230 Depot Road, Milford, CT 06460 Ph: (203) 878-4648, Fx: (203) 882-0885, E-mail: info@interfacedevices.com

More information

Fisher 2625 and 2625NS Volume Boosters

Fisher 2625 and 2625NS Volume Boosters Product Bulletin D200071X012 2625 and 2625NS Volume Boosters Fisher 2625 and 2625NS Volume Boosters A Fisher 2625 or 2625NS volume booster (figure 1) is used in conjunction with a positioner on a throttling

More information

Neotecha Tank Sampling Sapro

Neotecha Tank Sampling Sapro Tank sampling system for representative sampling without process interruption Features The sampling system assures a true representative sample every time without process interruption. The sampling system

More information

Safeguarding your process flow control system

Safeguarding your process flow control system Safeguarding your process flow control system 1 Cavitation Understanding Flashing and Cavitation and flashing are major causes of metal erosion in flow control systems. It occurs when a media goes through

More information

Quick Start Guide LIQ-QSG-499AOZ, Rev M July Rosemount 499AOZ. Dissolved Ozone Sensor

Quick Start Guide LIQ-QSG-499AOZ, Rev M July Rosemount 499AOZ. Dissolved Ozone Sensor Quick Start Guide LIQ-QSG-499AOZ, Rev M July 2017 Rosemount 499AOZ Dissolved Ozone Sensor Safety information CAUTION! SENSOR/PROCESS APPLICATION COMPATIBILITY The wetted sensor material may not be compatible

More information

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual Installation, Operation, and Maintenance Manual Welker Sampler Model GSS-1 The information in this manual has been carefully checked for accuracy and is intended to be used as a guide to operations. Correct

More information

REGULATORS FLOWMETERS HUMIDIFIERS. Professional GAUGES ASSESSORIES. Medical Apparatus. and Assessories ISO 13485/ISO 9001 CERTIFICATION

REGULATORS FLOWMETERS HUMIDIFIERS. Professional GAUGES ASSESSORIES. Medical Apparatus. and Assessories ISO 13485/ISO 9001 CERTIFICATION Medical Apparatus REGULATORS FLOWMETERS Professional Medical Apparatus and Assessories HUMIDIFIERS GAUGES ASSESSORIES ISO 13485/ISO 9001 CERTIFICATION Company Profile MORRIS ENGINEERING WORKS LTD. was

More information

AIR STAPLER MODEL: CSG1C Part No

AIR STAPLER MODEL: CSG1C Part No AIR STAPLER MODEL: CSG1C Part No. 3110375 0506 OPERATING & MAINTENANCE INSTRUCTIONS SPECIFICATIONS Min. Hose Size (ID)... 6mm (1/4 ) Air Inlet Connector... 10mm Quick Fit Ave. Air Consumption... 0.27 cfm

More information

Aging Cell, OFITE Style. Included Items

Aging Cell, OFITE Style. Included Items DRILLING FLUIDS EQUIPMENT For over 30 years OFI Testing Equipment (OFITE) has provided instruments and reagents for testing drilling fluids, well cements, completion fluids, and wastewater. In addition

More information

Model 4000 Pressure Controller

Model 4000 Pressure Controller FEATURES Multiple Configurations The 4000 series pressure controller can be configured into either proportional only or proportional plus reset mode with a minimum of parts. Rugged Design Die cast aluminum

More information

INSTRUCTION MANUAL LOW PRESSURE CALIBRATION PUMP MODEL PGL

INSTRUCTION MANUAL LOW PRESSURE CALIBRATION PUMP MODEL PGL INSTRUCTION MANUAL LOW PRESSURE CALIBRATION PUMP MODEL PGL Dear user, We have made every effort to ensure the accuracy of the contents of this manual. Should any errors be detected, we would greatly appreciate

More information

RB Series Regulating System

RB Series Regulating System RB Series Instruction Manual Form 5872 January 2010 RB Series Regulating System filtration module RegulatoR module Box connecting Bolt outlet Ball valve inlet Ball valve Figure 1. RB Series Regulating

More information

Instruction Manual Contact Pressure Gauge

Instruction Manual Contact Pressure Gauge MS11 Instruction Manual Contact Pressure Gauge Table of Contents 1. Safety Instructions 2. Intended Applications 3. Product Description and Functions 4. Installation 5. Commissioning 6. Maintenance 7.

More information

Techcon Systems TS1258 Pressure Pot

Techcon Systems TS1258 Pressure Pot Techcon Systems TS1258 Pressure Pot User Guide TABLE OF CONTENT 1. SAFETY. 3 1.1 Intended Use 3 1.2 Safety Precaution 3 2. CERTIFICATE OF COMFORMANCE 4 3. FEATURES. 5 4. SPECIFICATIONS 5 5. INSTALLATION

More information

INSTRUCTION MANUAL FOR MODEL 7360V VERTICAL CURING CHAMBER Revision E May

INSTRUCTION MANUAL FOR MODEL 7360V VERTICAL CURING CHAMBER Revision E May INSTRUCTION MANUAL FOR MODEL 7360V VERTICAL CURING CHAMBER Revision E May 2015 98-0520 S/N 2001 N. Indianwood Ave. Tulsa, Oklahoma 74012 U.S.A. TEL: (918) 250-7200 FAX: (918) 459-0165 E-mail: chandler.sales@ametek.com

More information

STIH) Technical Information Accessories for STIHL cut-off machines / drills. 1. New pressurized water tank

STIH) Technical Information Accessories for STIHL cut-off machines / drills. 1. New pressurized water tank STIH) Technical Information 8.00 Accessories for STIHL cut-off machines / drills Contents. New pressurized water tank. Summary. New pressurized water tank The previous pressurized water tank 4 670 600

More information

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC Mechatronic pressure measurement Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC WIKA data sheet PV 35.41 Process Compact Series Applications Differential pressure monitoring

More information

Fisher and Whisper Disk Diffusers

Fisher and Whisper Disk Diffusers Instruction Manual Inline and Vent Diffusers Fisher 6010 -- 6015 and Whisper Disk Diffusers Contents Introduction... 2 Scope of Manual... 2 Description... 2 Principle of Operation... 3 Piping Considerations...

More information

Ball valve HKSF-W100. Ball valve HKSF-W100. RMA Kehl GmbH & Co. KG Oststrasse 17 D Kehl / Germany

Ball valve HKSF-W100. Ball valve HKSF-W100. RMA Kehl GmbH & Co. KG Oststrasse 17 D Kehl / Germany Ball valve HKSF-W100 RMA Kehl GmbH & Co. KG Oststrasse 17 D-77694 Kehl / Germany info@rma-kehl.de www.rma-armaturen.de 1 Design Features: RMA-ball valves type HKSF-W are fully welded and completely maintenance-free

More information

Fisher DVI Desuperheater Venturi Inline

Fisher DVI Desuperheater Venturi Inline Instruction Manual DVI Desuperheater Fisher DVI Desuperheater Venturi Inline Contents Introduction... 1 Scope of Manual... 1 Description... 1 Principle of Operation... 2 Installation... 3 Operating Instructions...

More information

MULTICHANNEL. Labnet International, Inc.

MULTICHANNEL. Labnet International, Inc. Labnet International, Inc. A B A1 A2 C F D H E 4A 4B 4C 4D G CONTENTS 1 - INTRODUCTION 2 - VOLUME SETTING 3 - METHOD OF PIPETTING 4 - RECOMMENDATIONS - RECALIBRATION 6 - CLEANING AND STERYLIZATION 7 -

More information

PRO-50 Instrument Supply Regulator

PRO-50 Instrument Supply Regulator Features CRN Approved The PRO-50 Regulator has been granted a Canadian Registration Number. Sour Service Capability Available in NACE configurations that comply with NACE MR0175/MR0103. Environmental limits

More information

Transferpette. Lightweight precise rugged reliable!

Transferpette. Lightweight precise rugged reliable! Lightweight precise rugged reliable! Transferpette Solutions for S cience F I R S T C L A S S B R A N D The Transferpette S microliter pipettes provide all features required for pipetting in Life Science

More information