Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

Size: px
Start display at page:

Download "Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08"

Transcription

1 Prop. -Way Pressure-Reducing Cart., Size / SAE 8 Q max = 1 l/min (4 gpm), p max = bar (6 psi) Direct acting, electrically operated 1 Description proportional -way pressure-reducing cartridges are size / SAE 8, high performance screwin cartridges with an /4-16 UNF mounting thread. They reduce the outlet pressure in as a function of the control current signal and independently of the inlet pressure in 1. In the initial position (solenoid de-energised) the inlet of the -way pressure-reducing cartridge is shut off and the outlet is connected to tank (port ). In control mode, the connection 1 opens until the pressure in port reaches the preset level. If the pressure rises above the preset level, the control spool opens the connection until balance is attained. Two pressure ranges are available, with maximum Compact construction for cavity type AM /4-16 UNF Operated by a proportional solenoid pressure ranges available Excellent stability over the whole pressure and flow range All exposed parts with zinc-nickel plating High pressure wet-armature solenoids The slip-on coil can be rotated, and it can be replaced without opening the hydraulic envelope Various plug-connector systems and voltages are available Can be fitted in a line-mounting body operating pressure (inlet pressure) p max bar. These -way pressure-reducing cartridges are predominantly used for reducing a system pressure in mobile and industrial applications. Thanks to the special terminal assignment, a proportional function can be achieved in manifold control blocks featuring WK... valves by using these valves in a way that does not require any redesign of the block. All external parts of the cartridge are zinc-nickel plated to DIN 979 and are thus suitable for use in the harshest operating environments. If you intend to manufacture your own cavities or are designing a line-mounting installation, please refer to the section Related data sheets. Symbol Technical data General characteristics Designation proportional -way pressure-reducing cartridge Design direct acting, electrically operated Mounting method screw-in cartridges /4-16 UNF Tightening torque 4 Nm ± 1 % ( ft-lbs ± 1 %) Size nominal size / SAE 8, cavity type AM Weight.4 kg (.9 lbs) Mounting attitude unrestricted (preferably vertical, coil down) Ambient temperature range - C + C (-1 F +1 F) Reference: 4-P-911-EN- Issue:.17 1/

2 Hydraulic characteristics Maximum operating pressure bar (6 psi) Maximum flow rate 1 l/min (4 gpm) Nominal pressure ranges 4 bar, 7 bar (64 psi, 1 psi) Flow direction see symbols Hydraulic fluid HL and HLP mineral oil to DIN 1 4; for other fluids, please contact BUCHER Hydraulic fluid temperature range - C +7 C (-1 F +18 F) Viscosity range Minimum fluid cleanliness Cleanliness class to ISO 446 : mm /s (cst), recommended...1 mm /s (cst) class 18/16/1 Electrical characteristics Supply voltage Control current Coil resistance R - cold value at C - max. warm value Recommended PWM frequency (dither) Hysteresis with PWM Reversal error with PWM Sensitivity with PWM Reproducibility with PWM Switching time Relative duty cycle Protection class to ISO 6 / EN 6 9 Electrical connection 1 V DC, 4 V DC 1 V = 14 ma, 4 V = 76 ma 1 V =.8 / 4 V =.9 1 V = 9.1 / 4 V =.7 Hz 6 % I N 6 % I N < % I N < % p N see performance graphs 1 % IP 6 / IP 67 / IP 69K, see Ordering code (with appropriate mating connector and proper fitting and sealing) -pin square plug to ISO 44 / DIN 4 6 (standard) for other connectors, see Ordering code / 4-P-911-EN-/.17

3 4 Performance graphs measured with oil viscosity mm /s (cst) p = f (I) Pressure adjustment characteristic p [bar (psi)] 8 ( 11) P49.ai 6 (86) p N 7 bar (1 psi) 4 (7) (8) p N 4 bar (64 psi) I [ma] p = f (Q) Pressure - Flow rate characteristic p [bar (psi)] 1 P4.ai p N = 7 bar p [bar (psi)] (17) 9 (1) p 1 = bar (6 psi) 6 (86) (4) 1 7,., 7, 1 1, 1 (.6) (1.9) (1.) (.6) (.6) (1.) (1.9) (.6) (.) (4) Q [l/min (gpm)] p = f (Q) Pressure - Flow rate characteristic p [bar (psi)] 8 P41.ai p N = 4 bar p [bar (psi)] (11) 6 4 p 1 = bar (6 psi) (86) (7) (8) 1 (.6) 7, (1.9) (1.). (.6). 7, 1 1, 1 (.6) (1.) (1.9) (.6) (.) (4) Q [l/min (gpm)] 4-P-911-EN-/.17 /

4 Dimensions & sectional view /4 16UNF Ø M A = 4 [Nm] ± 1 % ( ft lbs ± 1 %) M A =.7 [Nm] ± 1 % ( ft lbs± 1 %) 6 Installation information IMPORTANT! When fitting the cartridges, note the mounting attitude (preferably vertical, with coil down automatic air bleed) and use the specified tightening torque. No adjustments are necessary, since the cartridges are set in the factory. Seal kit NBR no. DS-47-N 1) Item Qty. Description 1 1 O-ring 18, x, FKM ATTENTION! Only qualified personnel with mechanical skills may carry out any maintenance work. Generally, the only work that should ever be undertaken is to check, and possibly replace, the seals. When changing seals, oil or grease the new seals thoroughly before fitting them. IMPORTANT! 1) Seal kit with FKM (Viton) seals no. DS-47-V 1 O-ring no ,17 x 1,78 N9 1 O-ring no. 14 1,4 x 1,78 N9 4 1 O-ring no. 1 1,8 x 1,78 N9 O-ring 16, x, FKM 6 Backup ring 1.7 x 1.4 x 1.4 FI71 7 Backup ring 9.4 x 1.4 x 1. FI71 4/ 4-P-911-EN-/.17

5 7 Ordering code Ex. DRD S A - 7 M _ D _ DRD = direct acting, prop. pressure-reducing cartridge S = standard solenoid (proportional) A... Q = standard model - see relevant data sheets Z... R = special features - please consult BUCHER 7 = -way pressure function (external pilot drain) M = cavity type AM 7 = pressure range 7 bar (1 psi) 4 = pressure range 4 bar (64 psi) = nominal size (blank) = NBR (Nitrile) seals (standard) V = FKM (Viton) seals (special seals - please contact BUCHER) = design stage (omit when ordering new units)... = voltage e.g. 4 (4 V) D = current DC (blank) = ISO 44 / DIN 4 6 connection with mating plug (standard, IP 6) M1 = ISO 44 / DIN 4 6 connection without mating plug C = Kostal plug connection (IP 6) JT = Junior Timer radial plug connection (with protection diode, IP6) IT = Junior Timer axial plug connection (with protection diode, IP6) D = Deutsch plug connection DT4-P (IP 67/69K) mating plug not supplied DT = Deutsch plug connection DT4-P (with protection diode, IP 67/69K) S = AMP Superseal 1. (IP67) / Metri-Pack 1 (IP6) plug connection F = flying leads ( mm) 8 Related data sheets Reference (Old no.) Description 4-P-411 (i-) The form-tool hire programme 4-P-4181 (i-.11) Cavity type AM 4-P-111 (W-.141) Coils for screw-in cartridge valves 4-P-111 Amplifier unit for proportional valves (1-channel) PBS - A 4-P-1111 Amplifier card for proportional valves (1-channel) SAN- 4-P-7111 (G-4.) Line-mounting body, type GAMA (G /8 ) info.ch@bucherhydraulics.com 17 by Bucher Hydraulics AG Frutigen, CH-714 Frutigen All rights reserved. Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense. The information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to continual improvement, we reserve the right to amend the product specifications contained in this catalogue. Classification: P-911-EN-/.17 /

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cart., Size 2 4 Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 5 bar Direct acting, electrically operated 1 Description inverse proportional pressure-relief valves are direct acting screw-in cartridges

More information

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Proportional Pressure-Relief Cartridge Valve, Size 2...4 Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min, p max = 3 bar Direct acting, electrically operated 1 Description proportional pressure-relief valves are direct acting screw-in cartridges

More information

Inverse Prop. Pressure-Relief Cart., Size 2 4

Inverse Prop. Pressure-Relief Cart., Size 2 4 Inverse Prop. Pressure-Relief Cart., Size Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description inverse proportional pressure-relief valves are direct acting screw-in

More information

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Proportional Pressure-Relief Cartridge Valve, Size 2...4 Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description proportional pressure-relief valves are direct acting

More information

Proportional Throttle Cartridges, Size 16

Proportional Throttle Cartridges, Size 16 Proportional Throttle Cartridges, Size 16 Q max = 5 l/min, p max = 5 bar, Q N max = 14 l/min at p 1 bar Two-Stage, with Seat-Valve Shut-Off 1 Description Normally closed Seat-valve shut-off from 1 Compact

More information

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cart., Size 2 4 Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 35 bar Direct acting, electrically operated Description Compact construction for cavity type AL 3/-6 UNF Operated by a proportional

More information

Inverse Proportional Pressure-Relief Cartridge, Size 10

Inverse Proportional Pressure-Relief Cartridge, Size 10 Inverse Proportional Pressure-Relief Cartridge, Size 1 Q max = 12 l/min, p max = 3 bar Seated pilot, spool-type main stage, damped design 1 Description inverse-proportional pressure-relief valves are size

More information

Electrically Operated Pressure-Relief Cartridge, Size 10

Electrically Operated Pressure-Relief Cartridge, Size 10 Electrically Operated Pressure-Relief Cartridge, Size 1 Q max = 14 l/min (37 gpm), p max = bar (5 psi) seated pilot stage, spool-type design, with remote contral port Z Series WUVPOC-2, WUVPLC-2 1 Description

More information

3-Way Pressure-Reducing Cartridge, Size 2 4

3-Way Pressure-Reducing Cartridge, Size 2 4 -Way Pressure-Reducing Cartridge, Size 2 Q max = 2 l/min, p max = 25 bar Spool-type design, direct acting, with manual adjustment 1 Description Compact construction for cavity type AM /- UNF to Bucher

More information

Pressure-Relief Cartridge Valve, Size 4

Pressure-Relief Cartridge Valve, Size 4 Pressure-Relief Cartridge Valve, Size 4 Q max = 30 l/min, p max = 420 bar Seated design, direct acting, with mechanical operation Compact construction for cavity type AL 3/4-16 UNF High flow rates 7 pressure

More information

Cooler-Bypass Thermostat Valve, Size 16

Cooler-Bypass Thermostat Valve, Size 16 Cooler-Bypass hermostat Valve, Size Q max = l/min, p max = bar emperature-controlled, integral relief function, various pressure settings available Description emperature-dependent bypass control Integral

More information

Double Pilot Operated Cartridge Check Valve, Size 8

Double Pilot Operated Cartridge Check Valve, Size 8 Double Pilot Operated Cartridge Check Valve, Size 8 Q max = 7 l/min (19 gpm), p max = 35 bar (5 psi) pilot operated, two-stage, spring-closed cartridge-type poppet valve Compact design for cavity type

More information

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type Flow Control Valve Series LVM.. high flow rates (8 l/min) flow rates are unaffected by temperature change or when the higher load pressure alternates between the outlet ports proportional flow-sharing

More information

Leak-Free Load-Control Valve SAE ½ psi flange

Leak-Free Load-Control Valve SAE ½ psi flange Leak-Free Load-Control Valve SE ½ - 6000 psi flange Q max = 150 l/min [40 gpm], p max = 420 bar [6000 psi] leak-proof, two-stage hydraulic, SE-flange design 12--S... 1 Description Two-stage load-control

More information

PRESSURE COMPENSATORS TECNORD

PRESSURE COMPENSATORS TECNORD PRESSURE COMPENSATORS 2-way, Compensating / Reducing Valves GPM PSI LPM BAR MODEL CAVITY PAGE 8 3500 30 245 DF-CP2 7/8 14 UNF 60 16 3500 60 245 QC-CP2 Special 62 Typical Schematic Typical application for

More information

INVERS. Solenoid coil 24VDC 12 VDC Exm Exd Explosion protection marking:

INVERS. Solenoid coil 24VDC 12 VDC Exm Exd Explosion protection marking: direct operated INVERSE function available Q max = 2 l/min p max = bar INVERS Description EPDB The direct operated proportional pressure relief valve is built as a slip-in cartridge fitted in a connecting

More information

Pressure reducing valve, direct operated

Pressure reducing valve, direct operated Electric Drives and Controls Table of contents Hydraulics Pressure reducing valve, direct operated Model ZDR 6 D Nominal size 6 Series 4X Maximum operating pressure 20 bar (3050 PSI) Maximum flow 50 L/min

More information

Leak free Pipe Rupture Valve for Excavators

Leak free Pipe Rupture Valve for Excavators Leak free Pipe Rupture Valve for xcavators Series motion and progress Reference: 3 P 9575 1/11.6 Classification: 43.325.355...325.35 1/17 Contents Page 1 General description................................................................

More information

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics. Vickers heck Valves Operated heck Valves 4G-10, 20 Series, 20 Series 4T-06/10, 20 Series Typical Section 4T1-06-D*-20-U, illustrating external drain and decompression features asic haracteristics Maximum

More information

Pressure reducing valve, pilot operated, Model 3DR

Pressure reducing valve, pilot operated, Model 3DR RA 26 928/06.98 Pressure reducing valve, pilot operated, Model 3DR Nominal size 16 Series 5X Maximum operating pressure 3600 PSI (250 bar) Maximum flow 58.1 GPM (220 L/min) Contents Description Page Features

More information

BW0500AO. ByWire Elements BW0500AO Element 4/3 with side ports IBW0500 Interface

BW0500AO. ByWire Elements BW0500AO Element 4/3 with side ports IBW0500 Interface ywire Elements Element 4/3 with side ports IW5 Interface efore use, carefully read the GENERL INSTRUCTIONS FOR USE OF DIRECTIONL CONTROL VLVES 398SW5EN - 5--8 Technical data Nominal flow 5 l/min 3. US

More information

Leak-Free Load-Control Valve, Size 20

Leak-Free Load-Control Valve, Size 20 Leak-Free Load-Control Valve, Size 20 Qmax = 350 l/min [92 gpm], pmax = 420 bar [6000 psi] leak-proof, two-stage hydraulic, manifold mounting 20--P... 1 Description Whenever large loads are to be precisely

More information

MOUNTING SURFACE MOUNTING POSITION MAXIUMUM OPERATING PRESSURE FLUID OPERATING VISCOSITY FLUID CLEANLINESS HYSTERESIS REPEATABILITY THRESHOLD VOLTAGE

MOUNTING SURFACE MOUNTING POSITION MAXIUMUM OPERATING PRESSURE FLUID OPERATING VISCOSITY FLUID CLEANLINESS HYSTERESIS REPEATABILITY THRESHOLD VOLTAGE TYPICAL PERFORMANCE SPECIFICATIONS DESCRIPTION These proportional valves are direct operated pressure reducing valves. They can be used to control pressure in parts of a circuit. This valve incorporates

More information

3-Way Safety Block DSV

3-Way Safety Block DSV 3-Way Safety Block DSV DSV 10 - M DSV 10 - M - T-ball DSV 10 - EY 1. Description 1.1. GENERAL The 3-way safety block is used to shut off and discharge hydraulic accumulators or consumers. It complies with

More information

L6090 (LC04M-CBL) - L6095 (LC04M-CBD)

L6090 (LC04M-CBL) - L6095 (LC04M-CBD) or 3 way pressure compensated flow regulators L69 (LC4M-CBL) - L695 (LC4M-CBD) RE 1833-4 Edition:.16 Replaces: 7.1 Size 4 Series Maximum operating pressure 31 bar (45 psi) Maximum flow (-way) 1 l/min (3.

More information

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R Veljan Pressure Reducer Valve Series VR4R are pilot operated controls used to control pressure in a secondary part of a hydraulic circuit. Pressure is

More information

Proportional Directional Valve System

Proportional Directional Valve System roportional Directional Valve System Sectional Design and Flow Sharing rinciple Reference: 31--959-EN-3 Stand: 9.216 1/2 2/2 31--959-EN-3/9.216 Contents age 1 General... 5 1.1 Description... 5 1.2 Advantages...

More information

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R Veljan Pressure Reducer Valve Series VR4R are pilot operated controls used to control pressure in a secondary part of a hydraulic circuit. Pressure is

More information

Pressure reducing valve, pilot operated

Pressure reducing valve, pilot operated Pressure reducing valve, pilot operated RE 26928/09.07 Replaces: 10.97 1/8 Type 3DR Size 16 Component series 5X Maximum operating pressure 250 bar Maximum flow 220 l/min H5844 Table of contents Content

More information

Pressure reducing valve, direct operated

Pressure reducing valve, direct operated Electric Drives and Controls Table of contents Hydraulics Pressure reducing valve, direct operated Model DR 10 DP Nominal size 10 Series 4X Maximum reduced pressure 210 bar (3050 PSI) Maximum flow 80 L/min

More information

Cover headline. Cover subheadline. Check Valves

Cover headline. Cover subheadline. Check Valves Check Valves Cover headline Direct and pilot operated check valve functions for applications up to 5 bar (5 psi) and 7 L/min (6 USgpm) Cover subheadline EATON Screw-In Cartridge Valves E-VLSC-MC-E December

More information

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998 Auxiliary valve Sequence valve, 3-way Catalogue 9129 8542-02 (GB) 9129 8542-06 (US) October 1998 Sequence valve, 3-way Applications The sequence valve is designed to open or close a hydraulic pilot signal

More information

Safety and Shut-off Block SAF/DSV

Safety and Shut-off Block SAF/DSV 1. DESCRIPTION 1.1. GENERAL The HYDAC safety and shut-off block is used to shut off and discharge hydraulic accumulators or user units. It complies with the relevant safety standards in accordance with

More information

Check valve hydraulically pilot operated

Check valve hydraulically pilot operated Check valve hydraulically pilot operated RE 6/7.5 Replaces:. / Types SV and SL Nominal sizes to Component series X Maximum operating pressure 5 bar Maximum flow 55 l/min H555 Overview of contents Contents

More information

Flow Control Valves. 1 Description. 2 Symbols. Series MTKA, MTQA, MTCA 2.1 MTKA MTQA flow control valve. 1.1 MTKA flow control valve

Flow Control Valves. 1 Description. 2 Symbols. Series MTKA, MTQA, MTCA 2.1 MTKA MTQA flow control valve. 1.1 MTKA flow control valve Flow Control Valves Series MTK, MTQ, MTC MTQ... MTC... robust, uncomplicated, reliable these valves do not require maintenance. This lowers costs and reduces the risk of a system failure. can be provided

More information

Solenoid valves VZWF, force pilot operated

Solenoid valves VZWF, force pilot operated Key features and overview Function Normally closed solenoid valve with diaphragm and forced lifting. When the solenoid is energised, the differential pressure from the secondary side of the diaphragm is

More information

D62 - D63 Directional Control Valve l/min

D62 - D63 Directional Control Valve l/min D62 - D63 Table of Contents 1 1.1 1.2 Product Description... 2 Function... 2 Properties... 2 2 Technical Data... 3 3 3.1 3.2 Ordering Information... 4 Type code... 4 Versions currently available... 4 4

More information

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications Replaces: 04.95 Dual displacement motor 10VM Plug-in dual displacement motor 10VE for open and closed circuit applications Size 28-60 Series 5 Nominal pressure 280 bar Peak pressure 350 bar 10VM Contents

More information

4/3 Directional valve elements L8_P5 with proportional (ED-IP) control and with or without LS connections L8_P5 (ED-IP)

4/3 Directional valve elements L8_P5 with proportional (ED-IP) control and with or without LS connections L8_P5 (ED-IP) 4/3 Directional valve elements L8_5 with proportional (ED-I) control and with or without LS connections L8_5 (ED-I) RE 1831-7 Edition: 2.21 Replaces: 7.12 7.212 Size Series Maximum operating pressure 31

More information

Safety and Shut-off Block SAF/DSV

Safety and Shut-off Block SAF/DSV Safety and Shut-off Block SAF/DSV 1. DESCRIPTION 1.1. GENERAL The HYDAC safety and shut-off block is used to shut off and discharge hydraulic accumulators or consumers. It complies with the relevant safety

More information

Directional Controls

Directional Controls Vickers Directional Controls Directional Control Valves DG3V-3-*-60 Hydraulic Operated DG17V-3-*-60 Lever Operated DG18V-3-*-60 Air Operated DG20V-3-*-60 Cam Operated DG21V-3-*-60 Plunger Operated CETOP

More information

4/3 Directional valve elements L85L1...(EDC-LV) with manual lever operated control with flow sharing control (LUDV concept) L85L1...

4/3 Directional valve elements L85L1...(EDC-LV) with manual lever operated control with flow sharing control (LUDV concept) L85L1... 4/3 Directional valve elements L8L1...(EDC-LV) with manual lever operated control with flow sharing control (LUDV concept) L8L1...(EDC-LV) RE 1831-17 Edition: 2.216 Replaces: 7.12 Size 6 Series Maximum

More information

Function. Valve Size. Pilot Oil. p min. Bold: Designates Tier I products and options.

Function. Valve Size. Pilot Oil. p min. Bold: Designates Tier I products and options. Catalog HY14-255/US echnical Information ilot Operated ressure Reducing Valves Series VMY*6 General Series VMY*6 valves consist of the main stage with valve spools and the pilot stage with the proportional

More information

Series K Air service units G 1/8, G 1/4

Series K Air service units G 1/8, G 1/4 Air service units G /8, G /4 Series FK Filter, G /8 G /4.02 Series RK Pressure regulator, G /8 G /4.04 Series FRK Filter/regulator, G /8 G /4.06 Series OK Lubricator, G /8 G /4.08 Series FROK Two piece

More information

SDM to 8 sections monoblock valve D1WWDA02A

SDM to 8 sections monoblock valve D1WWDA02A SDM 1 SDM1 1 to 8 sections monoblock valve D1WWDA2A SDM1 Additional information This folder shows the product in the most standard configurations. Please contact Sales Dpt. for more detailed information

More information

The Size 16 Product Range

The Size 16 Product Range Screw-in Cartridges, Sandwich Bodies, Line-ounting Bodies The Size 6 Product Range ulti-functional Compact Economical Pressure: Flow Rate: 40 bar 50 l/min An Introduction to the Size 6 Product Range according

More information

Pressure control. Direct and pilot operated pressure control valves for applications up to 350 bar (5000 psi) and 300 L/min (80 USgpm)

Pressure control. Direct and pilot operated pressure control valves for applications up to 350 bar (5000 psi) and 300 L/min (80 USgpm) Hydraulic Screw-in Cartridge Valves (SiCV) Pressure control Direct and pilot operated pressure control valves for applications up to 5 bar (5 psi) and L/min (8 USgpm) Pressure control PRSSUR CONTROLS...-4

More information

Pressure relief valve, direct operated

Pressure relief valve, direct operated Pressure relief valve, direct operated RE 570/0.05 Replaces: 06.03 /8 Type DBD..K Size Component series X Maximum operating pressure 500 bar Maximum flow 0 l/min K9- Table of contents Contents Page Features

More information

Cartridge Valves Technical Information. Pressure Reducing, Quick Reference

Cartridge Valves Technical Information. Pressure Reducing, Quick Reference Quick Reference Pressure Reducing, Non-Relieving Model No. Description Flow* Pressure Page CP20-2 PRC 06 SDC10- NCS06/ Pressure Reducing, Non-Relieving, Direct Acting 40 l/min [10 US gal/min] 40 l/min

More information

Safety and Shut-off Block SAF/DSV

Safety and Shut-off Block SAF/DSV Safety and Shut-off Block SAF/DSV 1.1.1 Key to the circuit diagram Circuit diagram The HYDAC safety and shut-off block is used to shut off and discharge hydraulic accumulators or consumers. It complies

More information

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

Displacement 12, , Maximum flow rate (at 1450 rpm) bar. 00/07 ED PVD VARIABLE DISPLACEMENT VANE PUMPS SERIES 0 OPERATING PRINCIPLE The PVD pumps are variable displacement vane pumps with a mechanical type of pressure compensator. They allow instantaneous adjustment

More information

Air service units series K G1/8, G1/4

Air service units series K G1/8, G1/4 Air service units series K Series FK Filter 12.011 Series RK Pressure regulator 12.012 Series FRK Filter/regulator 12.013 Series OK Lubricator 12.014 Series FROK Two piece air service unit 12.015 Series

More information

SPCH/ Blowing block

SPCH/ Blowing block > > for linear stretch blow moulding machines > > Compact and safe design > > Best suited for PET bottles up to litres, depending on cycle time Technical features Medium: Compressed air (purity class 3..3

More information

4/2 way Pneumatic Solenoid Valve

4/2 way Pneumatic Solenoid Valve 4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11

More information

Pressure Reducing Valves Catalog Quick Reference

Pressure Reducing Valves Catalog Quick Reference Quick Reference Pressure Reducing, Non-Relieving Model No. Description Flow* Pressure Page 2 CP20-2 SDC0- Pressure Reducing, 20 bar PR - 5 PRC 06 NCS06/ Non-Relieving, Direct Acting [000 psi] 5 bar [4500

More information

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR SIT Group 836-837 TANDEM MULTIFUNCTIONAL GAS CONTROL MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR ALL ADJUSTMENTS ACCESSIBLE FROM ABOVE

More information

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection SPOOL VALVES pilot operated single/dual solenoid (mono/bistable function) ISO 07-8 mm - pad mounting body M connection x/ - / - / Series 0 ISO 07- (8 mm) FEATURES M connection on top of valve: reduces

More information

PRESSURE SEQUENCE VALVE TYPE UZK

PRESSURE SEQUENCE VALVE TYPE UZK PRESSURE SEQUENCE VALVE TYPE UZK Size 10, 20, 30 31,5 MPa up to 450 dm 3 /min WK 450 414 04. 2000r. Pressure sequence valves type UZK are used for switching a system or part of a system off when a set

More information

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10 / ED VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES OPERATING PRINCIPLE The VPPL are variable displacement axial-piston pumps with variable swash plate, suitable for applications

More information

Directional Valves. Hydraulic Operated Directional Valves

Directional Valves. Hydraulic Operated Directional Valves Service Data Vickers Directional Valves Hydraulic Operated Directional Valves (F*) DG3V 8 (B) ** (L) (X) (*) (*) 10 (EN**) Released 04/96 5007.03/EN/0496/S DG3V-8-*(C) - (X) - 10 Spring Centered 473726

More information

Intrinsically safe solenoid valves on/off controls - ATEX certification

Intrinsically safe solenoid valves on/off controls - ATEX certification www.atos.com Table E130-17/E Intrinsically safe solenoid valves on/off controls - ATEX certification valve body valve spool intrinsically safe solenoid electrical connector manual override DHW-0611/WP/6

More information

Pressure relief valve, direct operated. Type DBD. Features. Contents. RE Edition: Replaces:

Pressure relief valve, direct operated. Type DBD. Features. Contents. RE Edition: Replaces: Pressure relief valve, direct operated Type DBD R 2542 dition: 21-7 Replaces: 214-8 Size 3 Component series 1X Maximum operating pressure 3bar [915 psi] Maximum flow 33 l/min [87 US gpm] H5585 Features

More information

Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification ATEX, IECEx, EAC

Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification ATEX, IECEx, EAC www.atos.com Table -2/E Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification TEX, IEEx, E valve body spool ex-proof solenoid ex-proof inductive

More information

Cartridge Valves Technical Information Proportional Valves Quick Reference

Cartridge Valves Technical Information Proportional Valves Quick Reference Quick Reference Proportional Directional Model No. Description Flow* Pressure Page PSV-3- SDC- Proportional directional l/min 5. valve [6 ] [36 ] S 3 S Quick reference Proportional Directional Model No.

More information

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US Industrial Hydraulic Valves Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories Catalog HY14-2500/US Industrial Hydraulic Valves WARNING USR RSPONSIBILITY FAILUR OR IMPROPR

More information

CV08-20 Check Valve DIRECTIONAL VALVES. DESCRIPTION A screw-in, cartridge-style, hydraulic check valve for use as a blocking or load-holding device.

CV08-20 Check Valve DIRECTIONAL VALVES. DESCRIPTION A screw-in, cartridge-style, hydraulic check valve for use as a blocking or load-holding device. DIRECTIONAL VALVES CV08-20 Check Valve DESCRIPTION A screw-in, cartridge-style, hydraulic check valve for use as a blocking or load-holding device. OPERATION The CV08-20 allows flow passage from 1 to 2,

More information

Safety and Shut-off Block SAF/DSV

Safety and Shut-off Block SAF/DSV Safety and Shut-off Block SAF/DSV 1. Description 1.1. GENERAL The HYDAC safety and shut-off block is used to shut off and discharge hydraulic accumulators or consumers. It complies with the relevant safety

More information

Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Huade América 1

Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Huade América 1 Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Huade América 1 BEIJING HUADE HYDRAULIC INDUSTRIAL GROUP CO.,LTD. Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Size

More information

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R Veljan Pressure Reducer Valve Series VR4R are pilot operated controls used to control pressure a secondary part of a hydraulic circuit. Pressure is mataed

More information

Flow Controls. DG**-06 Series Stacking Valves. Vickers. ISO (D06) Interface Flows to 340 l/min (90 USgpm) Pressure to 210 bar (3000 psi)

Flow Controls. DG**-06 Series Stacking Valves. Vickers. ISO (D06) Interface Flows to 340 l/min (90 USgpm) Pressure to 210 bar (3000 psi) Vickers Flow Controls DG**-6 Series Stacking Valves ISO-441-8 (D6) Interface Flows to 34 l/min (9 USgpm) Pressure to 21 bar (3 psi) 5125./EN/598/A Introduction These stackable modules are designed for

More information

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application: MV-01 2/2-way Solenoid Valve for Fluids Description: Features / Nominal diameters 1/4-2 / Pressure up to 10 bar / 24 V DC and all common AC variants / Forced-lifting The pilot-controlled full-way valve

More information

Full Range Pressure Compensating Variable Flow Control

Full Range Pressure Compensating Variable Flow Control Engineering & Manufacturing Solutions Specifications: See flow chart for capacity. Rated for 3000 psi (207 bar). Weighs 7- ¾ lbs. (3.52 kg). 30-Micron Filtration Recommended. Torque to turn side lever

More information

APPLICATION. Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries

APPLICATION. Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries HYDRAULIC APPLICATION Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries Special vehicles Plastic and rubber machinery etc. CONTENTS Specification

More information

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure Z series for gage pressure Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection

More information

Safety and Shut-off Block SAF/DSV

Safety and Shut-off Block SAF/DSV Safety and Shut-off Block SAF/DSV 1. DESCRIPTION 1.1. GENERAL The HYDAC safety and shut-off block is used to shut off and discharge hydraulic accumulators. It complies with the relevant safety standards

More information

Applications. What moves your world

Applications. What moves your world Digital Control Proportional Valves Series D92 High-performance pressure control valve with high dynamics and the ability to easily and exactly tune the pressure controller gain The pq-proportional valves

More information

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94 Vickers Flow Controls Flow Controls FN, F(C)G, FRG Released 6/94 685 Table of Contents FN03/06/10 Model Series Application Data...............................................................................

More information

SOLENOID VALVES AND PNEUMATIC VALVES

SOLENOID VALVES AND PNEUMATIC VALVES 9 S E R I E S Electropneumatically and pneumatically operated valves Series 9 Assembly with sub-base (ISO 5599/1 Standards) Sizes 1, 2 and 3 The Series 9 electropneumatically or pneumatically operated

More information

ENGINEERING DATA. PVB Piston Pumps. w w w. F l u i D y n e F P. c o m Same Day Shipments of Units or Part Orders

ENGINEERING DATA. PVB Piston Pumps. w w w. F l u i D y n e F P. c o m Same Day Shipments of Units or Part Orders ENGINEERING DT PV Piston Pumps Same Day Shipments of Units or Part Orders Interchangeable Parts Fully Tested w w w. F l u i D y n e F P. c o m Email:cs@FluiDyneFP.com Contents asic characteristics.........................................................................................

More information

Pressure relief valve, direct operated Type DBD

Pressure relief valve, direct operated Type DBD Industrial Hydraulics Electric Drives and Controls Linear Motion and Assembly echnologies neumatics Service Automation Mobile Hydraulics RE 25 402/06.02 Replaces: 03.98 Material No.: 00772632a ressure

More information

Axial Piston Variable Pump A10V(S)O (US-Version)

Axial Piston Variable Pump A10V(S)O (US-Version) Axial Piston Variable Pump A1V()O (U-Version) RA-A 9271/3.12 1/52 Replaces: 12.9 Data sheet eries 31 ize NG18 ((A)A1VO) ize NG28 to 14 (A1VO) Nominal pressure 4 psi (28 bar) Maximum pressure 51 psi (35

More information

Pneumatic valve islands

Pneumatic valve islands Pneumatic valve islands The MEGA solenoid air operated spool valve JOUCOMATIC offers a concept of solenoid air operated spool valves which can be fitted together to form islands. Due to its new patented

More information

Fixed Displacement Motor A4FM

Fixed Displacement Motor A4FM Fixed Displacement Motor 4FM RE 91 12/4. replaces: 3.95 and RE 91 1 for open and closed circuits Sizes 22...5 Series 1, Series 3 Nominal pressure up to bar Peak pressure up to 45 bar Index Features 1 Ordering

More information

PVQ 13 A2 R SE 1 S 20 C-11 D

PVQ 13 A2 R SE 1 S 20 C-11 D PVQ - Variable Displacement Piston Pump PVQ 13 A2 R SE 1 S 2 C-11 D 1 2 3 4 6 7 8 9 1 1 Model Series PVQ Inline Piston Pump Variable Volume Quiet Series 4 Rotation Viewed from shaft end R Right hand, standard

More information

P2* MODULAR SUBPLATES FOR ISO (CETOP 03) VALVES

P2* MODULAR SUBPLATES FOR ISO (CETOP 03) VALVES 52 000/110 ED This series of modular subplates has been designed to make hydraulic circuits and can be used directly on power packs or on any other section of the machine. The subplates are assembled by

More information

Axial piston pumps type PVC

Axial piston pumps type PVC www.atos.com Table TA16-1/E Axial piston pumps type PV variable displacement, by a full line of mechanical controls PV are variable displacement axial piston pumps for medium pressure operation, low noise

More information

Monoblock directional control valves ML - Directional control valve

Monoblock directional control valves ML - Directional control valve Monoblock directional control valves ML - Directional control valve ML Before use, carefully read the GENERAL INSRUCIONS FOR USE OF DIRECIONAL CONROL VALVES 398SMD4I - 6--8 ML echnical data Nominal flow

More information

Axial piston pumps type PVC

Axial piston pumps type PVC www.atos.com Table TA16SK-1/E Axial piston pumps type PV variable displacement, by a full line of mechanical controls PV are variable displacement axial piston pumps for medium pressure operation, low

More information

SATURNSERIES INTERCHANGE > ISO (for the couplings)

SATURNSERIES INTERCHANGE > ISO (for the couplings) Saturn Block INTERCHANGE > ISO 16028 (for the couplings) PATENTED ISO 16028 TECHNICAL FEATURES AND OPTIONS Interchange ISO 16028 (for the couplings) Sealing description Nitrile NBR Connection system Push

More information

Pressure relief valve, direct operated

Pressure relief valve, direct operated ressure relief valve, direct operated R 25402/05.0 Replaces: 10.05 /1 ype DBD Nominal sizes to 0 Component series 1X Maximum operating pressure 0 bar Maximum flow 0 l/min H5585 Overview of contents Contents

More information

PLD 03 T A CASAPPA S.p.A.

PLD 03 T A CASAPPA S.p.A. GEAR FLOW DIVIDERS INDEX Section Page GENERAL FEATURES... 3 GENERAL DATA... 5 FLOW EQUALIZER... 6 FLOW DIVIDERS... 8 TYPICAL CIRCUITS... 10 NOTES ABOUT COMPOSITION... 12 PORTS DIMENSIONS.... 14 GROUP DIMENSIONS...

More information

4 qwer 2/2 3/2 4/2. Intrinsically Safe. Air and Inert Gas Intrinsically Safe Valves Brass, or Stainless Steel Bodies 1/4" to 1" NPT SERIES.

4 qwer 2/2 3/2 4/2. Intrinsically Safe. Air and Inert Gas Intrinsically Safe Valves Brass, or Stainless Steel Bodies 1/4 to 1 NPT SERIES. qwer Air and Inert Gas Valves Brass, or Stainless Steel Bodies 1/" to 1" NPT Features Designed solely for installation in intrinsically safe areas, with properly approved and sized current and voltage-limiting

More information

Chapter 10: Bidirectional Flow Controls

Chapter 10: Bidirectional Flow Controls Chapter 10: Bidirectional Flow Controls Objectives Learn about the patented, bidirectional flow control valves. Understand how the flow force affects the performance of the ZL70-36. Learn why there is

More information

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm Return Filters E 9 E E Tank top mounting Connection up to G / -6 SAE Nominal flow rate up to 5 l/min / 5.7 gpm Description Application In the return line circuits of hydraulic systems. Performance features

More information

Pump safety block. Type DBA, DBAW, DBAE(E) Features. Contents. RE Edition: Replaces: 11.10

Pump safety block. Type DBA, DBAW, DBAE(E) Features. Contents. RE Edition: Replaces: 11.10 ump safety block ype D, DW, DE(E) RE 25891 Edition: 2013-05 Replaces: 11.10 Size 16, 25, 32 Component series 2 Maximum operating pressure 350 bar Maximum flow 400 l/min H5872 Features Depressurized start-up

More information

VSD03M DIRECTIONAL CONTROL VALVES

VSD03M DIRECTIONAL CONTROL VALVES NFPA SIZE D03 TYPICAL PERFORMANCE SPECIFICATIONS Performance is measured on a four-way circuit (full circuit). Performance may e reduced from that shown if a three-way circuit (half circuit) is used, i.e.

More information

RE / Meter out pressure compensator Sandwich plate design Type SCA... /Series 2X. Description of function, Section 1/6. Replaces: 09.

RE / Meter out pressure compensator Sandwich plate design Type SCA... /Series 2X. Description of function, Section 1/6. Replaces: 09. Meter out pressure compensator Sandwich plate design Type SCA... /Series X Sizes 6, 5 up to 35 bar up to 35 L/min RE 9 47/.96 RE 9 47/.96 Replaces: 9.87 Sandwich plate design Load compensation in lines

More information

WK /2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32. Size 32 up to 42 MPa 700 dm 3 /min DESCRIPTION OF OPERATION

WK /2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32. Size 32 up to 42 MPa 700 dm 3 /min DESCRIPTION OF OPERATION 2/2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32 Size 32 up to 42 MPa 700 dm 3 /min WK 490 907 04.1999r. 2/2 way cartridge valve type URZS 32 can be used to build hydraulic systems

More information

Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm)

Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm) Vickers Cartridge Valves Load Controls Screw In Cartridge Valves Pressures to 50 bar (5000 psi) Flows to 90 l/min (50 USgpm) Rev. 2/99 722 Contents MODEL DESCRIPTION TYP. APPLICATION PRESSURE bar (psi)

More information

Logic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm)

Logic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm) Vickers artridge Valves Logic Elements Screw-in artridge Valves Pressures to 9 bar ( psi) Flows to l/min (8 USgpm) Revised 9/98 7 ontents MODEL DESRIPTION TYPIL PPLITION PRESSURE bar (psi) RTED FLOW l/min

More information