BAUER PURE AIR THE CONCEPT FOR PURE BREATHING AIR.

Size: px
Start display at page:

Download "BAUER PURE AIR THE CONCEPT FOR PURE BREATHING AIR."

Transcription

1 BAUER PURE AIR THE CONCEPT FOR PURE BREATHING AIR. SECURITY PRECISION INDEPENDENCE WORLDWIDE CERTIFIER

2 2 PURE AIR FIRE FIGHTING TAKE ADVANTAGE OF BAUER PURE AIR. Get certified now as a BAUER PureAir station!

3 PURE AIR FIRE FIGHTING 3 WHY IS BAUER PURE AIR SO ATTRACTIVE? My breathing air is pure. It s good if you can be absolutely sure of this. Because in an emergency, you must be able to rely on the fact that each cylinder is filled with perfect breathing air. Therefore, BAUER KOMPRESSOREN developed its own worldwide breathing air quality standard. BAUER PureAir. This seal of quality for BAUER breathing air compressors increases safety when filling breathing air cylinders. Even if you already offer breathing air meeting DIN EN 12021:2014, BAUER PureAir is a real benefit for you: The supervised set-up of your compressor and the monitoring of your breathing air filling station assures permanent compliance1 with the standard. And the PureAir certification points out clearly that you take the safety of your colleagues seriously - a quality plus which can make the difference. Make use of the advantagees BAUER PureAir offers you. Have your company certified now as a BAUER PureAir station! 1 Assuming proper maintenance and installation of the systems in accordance with operating instructions/operating manuals, and using the BAUER AERO-GUARD in cases where intake air CO2 concentration exceeds the levels required by the applicable breathing air standard. No consideration of local TLV values.

4 4 PURE AIR FIRE FIGHTING

5 PURE AIR FIRE FIGHTING 5 WHAT ARE THE ADVANTAGES OF PURE AIR CERTIFICATION? With certification as a BAUER PureAir station, you gain an advantage over other fire fighting brigades: an attribute proving you to be a particularly safety-conscious and trustworthy company. At the same time, you achieve increased legal security. Because you are undertaking everything to ensure filling with pure breathing air. BAUER KOMPRESSOREN will support you: In addition to costfree presence on including a link to your website, you have the chance of being referenced in the BAUER advertising campaign and on social media sites by BAUER KOMPRESSOREN. Moreover, you will receive from us your personal PureAir certificate and the latest PureAir starter pack, documenting your active responsibility as a PureAir station. The PureAir seal can be used for advertising purposes.

6 6 PURE AIR FIRE FIGHTING Filling area with PureAir certification at Y-40, the deepest thermal water diving pool in the world in Montegrotto, Italy.

7 PURE AIR FIRE FIGHTING 7 WHICH PRECONDITIONS HAVE TO BE MET? For certification as a BAUER PureAir station, you have to fulfil four preconditions: 1. You arrange for the correct installation of the compressor unit according to the operating instructions. Consequent observance of these regulations prevents, for example, the intake air being contaminated with carbon monoxide exhaust from a combustion engine. 2. You commit to using original BAUER filter cartridges. Only the manufacturing of these cartridges under industrial conditions enables a consistent standard of quality. 3. You monitor the air quality of your BAUER filling centre using an internal or downstream B-SECURUS filter monitoring system, thus preventing overrunning the service life of the cartridge. 4. You agree to the annual inspection of your filling centre acc. to DIN EN 12021:2014 by an authorised BAUER PureAir partner. 5. Additional requirement for PureAir GOLD certification: Online measurement of CO, CO 2 and O 2 with a BAUER B-DETECTION online gas measurement system.

8 8 PURE AIR FIRE FIGHTING

9 PURE AIR FIRE FIGHTING 9 HOW DO YOU INSTALL YOUR COMPRESSOR UNIT CORRECTLY? The first step to BAUER PureAir certification of your diving centre: 1. The floor must be even, dust-free and suited for the weight and vibration load imposed by the compressor. 2. The intake hose - maximum length 3 m, kink-proof and with sufficiently large section - has to be suspended high, dry and facing against the wind. 3. The cooling air flow of the fan and the wind must have the same direction. 4. Faultless air intake and exhaust air during compressor operation must be guaranteed. Re-aspiration of exhaust gas must be avoided under all circumstances. Particularly, proximity to roads with heavy traffic. 5. The ambient temperature must be between 5 C and 45 C. 6. We also recommend measuring your ambient air to exclude generally high CO or CO 2 levels.

10 10 PURE AIR FIRE FIGHTING WHY BAUER FILTER CARTRIDGES ARE INDISPENSABLE FOR YOU Only industrial manufacturing conditions ensure that a filter cartridge is filled under hygienic and unsaturated conditions and unsaturated. BAUER takes care of this on your behalf. The in-house filling of our filter cartridges ensures perfect air flow for optimal air purification. Original filter cartridges from BAUER are filled using only high-quality materials in the optimum mix. Then, each single cartridge is vacuum-packed, sealed and checked for leakage. This explains why BAUER filter cartridges offer optimal filtering - for safety that may save lives twice other.

11 PURE AIR FIRE FIGHTING 11 The BAUER cartridge packing is water-vapour-tight and extremely robust. The multi-layered integrated aluminium foil optimises the handling and the transport of the cartridges by maintaining the protective vacuuming.

12 12 PURE AIR FIRE FIGHTING WHAT DOES A BREATHING AIR PURIFICATION SYSTEM HAVE TO ACHIEVE? Compressors from BAUER rank among the safest breathing air compressors worldwide. They are equipped with proven purification systems which often clearly outperform the required safety limits of the standard DIN EN 12021: Original BAUER filter cartridges are filled using only high-quality materials in the optimal mix, vacuum-packed and subsequently checked for leakage. The standard filter cartridge prevents water or oil from penetrating into breathing air during air compression. For compressors with combustion engines a special cartridge is offered, which prevents the risk of critical carbon monoxide content form apiration of exhaust gases. Diving centres applying for certification in compliance with the BAUER PureAir standard have to equip their breathing air filling centre with a BAUER B-SECURUS purification system. 1 CO removal only with BAUER special cartridge up to a maximum concentration of 25 ppm CO in the intake air. The compressed clean breathing air then contains no more than 5 ppm CO. The CO2 concentration in the intake air must not exceed the maximum allowable limit according to DIN EN 12021:2014! Local TLV values are not considered.

13 P 61 Purification System PURE AIR FIRE FIGHTING 13

14 14 PURE AIR FIRE FIGHTING HOW DOES B-SECURUS KEEP YOUR BREATHING AIR PURE? Even the slightest risk is too high. Therefore, each BAUER PureAir station must be equipped with B-SECURUS, the filter monitoring system from BAUER. B-SECURUS indicates in good time when the cartridge needs be changed and shuts down the unit automatically as soon as the cartridge is saturated. Unlike conventional systems, B-SECURUS measures the humidity content of the compressed air right from the cartridge. This excludes two of the main causes for polluted breathing air: use of self-filled filter cartridges and belated catridge replacement. As the unit only shuts down as soon as the filter is saturated, every cartridge can be completely used eliminating the need for premature replacement for safety reasons. Thus, B-SECURUS offers you not only safety, but also additional cost-effectiveness.

15 PURE AIR FIRE FIGHTING 15

16 16 PURE AIR FIRE FIGHTING

17 PURE AIR FIRE FIGHTING 17 HOW DO YOU BECOME A BAUER PURE AIR STATION? Do you wish to become a PureAir station? If you are operating a BAUER filling centre with B-SECURUS monitoring system, you can apply for BAUER PureAir certification. Only authorised BAUER partners with successfully completed PureAir training at the BAUER headquarters in Munich are granted this certificate. Inspection verifies the correct installation and the air quality of the compressor unit. The water content and the oil, oxygen, carbon dioxide and carbon monoxide concentrations in the breathing air are measured acc. to DIN EN 12021:2014. This European standard defines the purity of compressed air for breathing equipment. Correct observance of the maintenance intervals is also checked, and the result is registered in a test log. A positive result will lead to your filling station being certified. Your certification is valid for one year maximum. There-after, you will require further visits from quality controllers at regular intervals, and after 12 months at the lastest. This procedure ensures that BAUER PureAir is the worldwide seal of quality for breathing air filling stations using BAUER units. Why not for you?

18 18 PURE AIR FIRE FIGHTING BAUER B-DETECTION BASIC online gas measuring system BAUER B-DETECTION MOBILE gas measuring system

19 PURE AIR FIRE FIGHTING 19 HOW DO YOU OBTAIN RELIABLE INFORMATION ABOUT AIR QUALITY AROUND THE CLOCK? When it comes to ensuring the safety of your team members, you want to be the one in charge. But how can you be sure that the results of your breathing air purity checks are delivering absolute reliability all the time? With the B-DETECTION range of online measuring instruments, BAUER KOMPRESSOREN has the answer: Three instruments featuring different functions, each tailormade for its intended purpose and all delivering the level of reliability and quality that can be expected from breathing air compressors by the world s market leader. Are you always on the move, but want to stay abreast of air quality levels at all times, no matter where you are? B-DETECTION MOBILE is the perfect solution for you: housed in a lightweight, portable case, it features an on-board battery and display, and is also suitable for checking cylinders. Are you operating a stationary filling station and want to monitor air purity using your system display? B-DETECTION BASIC is your answer. Or maybe an additional measurement of pressure dew point is what you re looking for? If so, B-DETECTION PRO is the right choice for you. So when are you going to make monitored breathing air a part of your system?

20 20 PURE AIR FIRE FIGHTING MEASUREMENT CERTIFICATION MEASUREMENT ONCE A YEAR CONTINUOUS MEASUREMENT OF O2, CO, CO2 AND HUMIDITY WITH B-SECURUS CONTINUOUS MEASUREMENT OF O2, CO, CO2, AND HUMIDITY WITH PRESSURE DEW POINT SENSOR BASIC CERTIFICATION USING DRÄGER AERO- TEST + O2-TUBES OR FACTAIR SYSTEM OR B-DETECTION MOBILE (TEMPORARY MEASUREMENT) GOLD CERTIFICATION B-DETECTION MOBILE WATER-PROOF FOR OUTDOOR OPERATION RESIDUAL OIL MEAS- UREMENT AT LEAST ONCE A YEAR B-DETECTION BASIC STATIONARY SYSTEM WITH DATA LOGGER FOR USE WITH COMPRESSORS WITH B-CONTROL RESIDUAL OIL MEAS- UREMENT AT LEAST ONCE YEAR B-DETECTION PRO WITH SMART SENSORS FOR AUTOMATIC CALIBRATION RESIDUAL OIL MEASURE- MENT AT LEAST ONCE A YEAR. SENSORS REPORT AUTOMATICALLY SCHED- ULED CALIBRATION AND END OF LIFE.

21 PURE AIR FIRE FIGHTING 21 WHAT IS THE NEW PURE AIR GOLD CERTIFICATION FROM BAUER? As the world s market leader in the field of breathing air compressors, BAUER considers breathing air purity to be its top priority. Drawing inspiration from gold s unsurpassable value in the world of finance, BAUER has now introduced its own gold standard for breathing air monitoring: PureAir GOLD certification. This new certification level reaches beyond the scope of the established BAUER PureAir certification, the main difference being that it involves continuous online monitoring of air quality. The new instruments from the B-DETECTION range are used to achieve this. They monitor the breathing air that is compressed in the compressor, ensuring that it adheres to the legal limit values for CO, CO 2, O 2 and partly also humidity. The annual test that was previously performed only covered oil content in the air. So when are you going to go for gold?

22 22 PURE AIR FIRE FIGHTING WHY BAUER PURE AIR? A top-spot demands top equipment. Pure air is part of it. Therefore BAUER PureAir. Michael Kurz, base operator, East African Dive Centre Tanzania As we wish to offer more safety to our customers, we favour BAUER PureAir Mohamed Waheed, director, MERIDIS Dive & Relax Maldive Islands Like a Swiss watch, BAUER PureAir stands for quality. Fritz Guidon, director Hotel Guidon Switzerland

23 PURE AIR FIRE FIGHTING 23

24 24 PURE AIR FIRE FIGHTING The owner of the indoor diving centre Y-40, Emanuele Boaretto (centre) together with his family team Giovanni Boaretto (right) and Antonio Gomiero (left)

25 PURE AIR FIRE FIGHTING 25 WHAT MADE PURE AIR THE RIGHT CHOICE FOR Y-40, THE WORLD S DEEPEST INDOOR DIVING POOL? When architect Emanuele Boaretto embarked on the quest to make his vision of the world s deepest thermal diving pool a reality, he brought to it the keen sense of perfectionism he had honed in his chosen profession. Nothing but the best would do. And nowhere did this matter more than in the quality of the most important equipment in the entire pool: the compressors that would provide pure breathing air in line with DIN EN 12021:2014. Two high-performance BAUER compressors featuring B-SECURUS filter monitoring were his choice and the PureAir certification that was purposely chosen for Y-40 provides divers with that extra layer of safety. Using only the most expensive materials, the Y-40 pool was erected in Abano-Montegrotto Terme, Italy, as a veritable temple to diving designed to cater to a highly discerning clientele. The facility s centrepiece is a vertical deep-water diving section that plunges a whopping 42 metres into the ground making it the world s deepest, as documented in the Guinness Book of Records. So when are you going to get certified?

26 26 PURE AIR FIRE FIGHTING WHY YOU SHOULD JOIN PUREAIR? Are you PureAir certified? If so, you are offering your colleaguesexactly the safety they are looking for. Our website gives you the most important information about the topic of PureAir. The BAUER PureAir stations are logged in the world map show ing: filling centres with BAUER PureAir certification worldwide. You can search for individual PureAir stations by using the full-text search tool. By clicking on the appropriate marker flag he receives further information about the breathing air filling center. With a further mouse-click, interested persons can access your website or contact you by . As a newly certified BAUER PureAir station, you will automatically be included in this website - our cost-free service for BAUER PureAir stations. When will you become a member?

27 PURE AIR FIRE FIGHTING 27

28 Get yourself certified! BAUER KOMPRESSOREN GmbH Stäblistr Munich, Germany Tel. +49 (0) Fax +49 (0) info@bauer-kompressoren.de BAUER Pure Air - For Operators N Subject to technical change without notice

BAUER PURE AIR THE CONCEPT FOR PURE BREATHING AIR

BAUER PURE AIR THE CONCEPT FOR PURE BREATHING AIR BAUER PURE AIR THE CONCEPT FOR PURE BREATHING AIR SECURITY PRECISION INDEPENDENCE WORLDWIDE CERTIFIER 2 PURE AIR FIRE FIGHTING TAKE ADVANTAGE OF BAUER PURE AIR. Get certified now as a BAUER PureAir station!

More information

FILTER CARTRIDGES THE GENUINE PRODUCT FOR YOUR PROTECTION AND THEIR SAFETY.

FILTER CARTRIDGES THE GENUINE PRODUCT FOR YOUR PROTECTION AND THEIR SAFETY. FILTER CARTRIDGES THE GENUINE PRODUCT FOR YOUR PROTECTION AND THEIR SAFETY. BREATHING AIR INDUSTRY WHY YOU SHOULD OPT FOR BAUER FILTER CARTRIDGES. TESTED COMPONENTS protect lives, health and equipment.

More information

B-DETECTION PLUS THE NEXT GENERATION MOBILE AND STATIONARY GAS MEASUREMENT SYSTEMS

B-DETECTION PLUS THE NEXT GENERATION MOBILE AND STATIONARY GAS MEASUREMENT SYSTEMS B-DETECTION PLUS THE NEXT GENERATION MOBILE AND STATIONARY GAS MEASUREMENT SYSTEMS SPORTS & SAFETY 2 B-DETECTION PLUS BAUER KOMPRESSOREN BECAUSE ROUGHLY ISN T IN YOUR VOCABULARY Even when your compressor

More information

KOMPRESSOREN THE LUNGS OF YOUR COMPRESSOR THE BAUER P-FILTER SYSTEM. No matter whether you count on the purest breathing

KOMPRESSOREN THE LUNGS OF YOUR COMPRESSOR THE BAUER P-FILTER SYSTEM. No matter whether you count on the purest breathing THE BAUER P-FILTER SYSTEM THE LUNGS OF YOUR COMPRESSOR Fotos: Ralf Deichelmann No matter whether you count on the purest breathing air as a diver or firefighter or if you have to trust in perfectly purified

More information

MEASURING WATER CONTENT IN COMPRESSED BREATHING AIR IN COMPLIANCE WITH EN 12021:2014 ULTRA-PRECISE AND ULTRA-RELIABLE WITH POLYMER TECHNOLOGY

MEASURING WATER CONTENT IN COMPRESSED BREATHING AIR IN COMPLIANCE WITH EN 12021:2014 ULTRA-PRECISE AND ULTRA-RELIABLE WITH POLYMER TECHNOLOGY MEASURING WATER CONTENT IN COMPRESSED BREATHING AIR IN COMPLIANCE WITH EN 12021:2014 ULTRA-PRECISE AND ULTRA-RELIABLE WITH POLYMER TECHNOLOGY SPORTS & SAFETY BAUER KOMPRESSOREN WHY PRECISE MEASUREMENT

More information

THE COMPACT LINE. Mobile power packs in convincing BAUER quality l/min 225 / 330 bar TOUGH RELIABLE WELL ESTABLISHED

THE COMPACT LINE. Mobile power packs in convincing BAUER quality l/min 225 / 330 bar TOUGH RELIABLE WELL ESTABLISHED THE COMPACT LINE Mobile power packs in convincing BAUER quality 100 140 l/min 225 / 330 bar TOUGH RELIABLE WELL ESTABLISHED COMPACT LINE mobile breathing air compressors for high demands Due to its legendary

More information

THE NEW SP SERIES MAXIMUM CAPACITY MINIMUM FOOTPRINT

THE NEW SP SERIES MAXIMUM CAPACITY MINIMUM FOOTPRINT THE NEW SP SERIES MAXIMUM CAPACITY MINIMUM FOOTPRINT SPORTS INDUSTRY & SAFETY 2 THE NEW SP SERIES BAUER KOMPRESSOREN BAUER KOMPRESSOREN THE NEW SP SERIES 3 JOINT INNOVATION THE CONCEPT BEHIND THE NEW SP

More information

MINI-VERTICUS & VERTICUS THE NEXT GENERATION INDUSTRIAL COMPRESSORS FOR AIR, NITROGEN AND RARE GASES

MINI-VERTICUS & VERTICUS THE NEXT GENERATION INDUSTRIAL COMPRESSORS FOR AIR, NITROGEN AND RARE GASES MINI-VERTICUS & VERTICUS THE NEXT GENERATION INDUSTRIAL COMPRESSORS FOR AIR, NITROGEN AND RARE GASES IN DU ST RY 2 MINI-VERTICUS & VERTICUS BAUER KOMPRESSOREN MINI-VERTICUS & VERTICUS STATIONARY COMPRESSORS

More information

MINI-VERTICUS & VERTICUS THE NEXT GENERATION INDUSTRIAL COMPRESSORS FOR AIR, NITROGEN AND RARE GASES

MINI-VERTICUS & VERTICUS THE NEXT GENERATION INDUSTRIAL COMPRESSORS FOR AIR, NITROGEN AND RARE GASES MINI-VERTICUS & VERTICUS THE NEXT GENERATION INDUSTRIAL COMPRESSORS FOR AIR, NITROGEN AND RARE GASES IN DU ST RY 2 MINI-VERTICUS & VERTICUS BAUER KOMPRESSOREN MINI-VERTICUS & VERTICUS STATIONARY COMPRESSORS

More information

the new Ve- / VSE Range

the new Ve- / VSE Range the new Ve- / VSE Range Pure Power, perfect price 30-680 l/min 5 / 330 / 0 bar FULFILLS THE REQUIREMENT FOR LARGE QUANTITIES OF BREATHING AIR open or Super silent EASY OPERATION Breathing air acc. to DIN

More information

THE NEW SP SERIES MAXIMUM CAPACITY MINIMUM FOOTPRINT

THE NEW SP SERIES MAXIMUM CAPACITY MINIMUM FOOTPRINT THE NEW SP SERIES MAXIMUM CAPACITY MINIMUM FOOTPRINT SPORTS INDUSTRY & SAFETY 2 THE NEW SP SERIES BAUER KOMPRESSOREN JOINT INNOVATION THE CONCEPT BEHIND THE NEW SP SERIES PISTON AND AIR END COMBINED IN

More information

B-NITROX SYSTEMS THE SAFE AND SECURE SOLUTION FOR PRODUCING AND COMPRESSING NITROX

B-NITROX SYSTEMS THE SAFE AND SECURE SOLUTION FOR PRODUCING AND COMPRESSING NITROX B-NITROX SYSTEMS THE SAFE AND SECURE SOLUTION FOR PRODUCING AND COMPRESSING NITROX SPORTS & SAFETY QUALITY IS THE BEDROCK OF OUR BUSINESS FOR FURTHER INFORMATION about our product portfolio and the products

More information

BAUER ACCESSORY SYSTEMS THE IDEAL ENHANCEMENT TO YOUR COMPRESSOR

BAUER ACCESSORY SYSTEMS THE IDEAL ENHANCEMENT TO YOUR COMPRESSOR BAUER ACCESSORY SYSTEMS THE IDEAL ENHANCEMENT TO YOUR COMPRESSOR BREATHING AIR INDUSTRY BAUER SETS NEW STANDARDS. AGAIN AND AGAIN. Since its foundation, BAUER KOMPRESSOREN has aimed for leadership in the

More information

B-NITROX SYSTEMS THE SAFE AND SECURE SOLUTION FOR PRODUCING AND COMPRESSING NITROX

B-NITROX SYSTEMS THE SAFE AND SECURE SOLUTION FOR PRODUCING AND COMPRESSING NITROX B-NITROX SYSTEMS THE SAFE AND SECURE SOLUTION FOR PRODUCING AND COMPRESSING NITROX S PO RTS & SAF ET Y QUALITY IS THE BEDROCK OF OUR BUSINESS FOR FURTHER INFORMATION about our product portfolio and the

More information

THE WATER-COOLED INDUSTRIAL RANGE

THE WATER-COOLED INDUSTRIAL RANGE Energy-efficient compressor systems for air and gases 25 420 bar 55 1716 m 3 /h WATER-COOLED PRESSURE-RESISTANT CRANKCASES for Air, nitrogen, cng and rare gases The water-cooled industrial range from BAUER

More information

Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air. PE 250-TE with compressor control (optional equipment)

Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air. PE 250-TE with compressor control (optional equipment) Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air Types: PE 200-TE PE 250-TE PE 300-TE Production status: F02 PE 250-TE with compressor control (optional equipment) General Medium

More information

STATIONARY UNITS FOR FIREFIGHTING KAP- / VERTICUS - RANGE

STATIONARY UNITS FOR FIREFIGHTING KAP- / VERTICUS - RANGE KAP- / VERTICUS - RANGE STATIONARY UNITS FOR FIREFIGHTING Fotos: Ralf Deichelmann When firefighters are concentrating all efforts into saving people's lives, health and possessions, then there's only one

More information

POSEIDON EDITION COMPRESSORS FOR SPORTS & SAFETY APPLICATIONS

POSEIDON EDITION COMPRESSORS FOR SPORTS & SAFETY APPLICATIONS POSEIDON EDITION COMPRESSORS FOR SPORTS & SAFETY APPLICATIONS SPORTS & SAFETY USER-FOCUSED FEATURES, UNCOMPROMISING QUALITY FOR MORE INFORMATION about our product programme and the products shown here,

More information

Our scope......your choice. An overview of the BAUER breathing air products

Our scope......your choice. An overview of the BAUER breathing air products Our scope......your choice An overview of the BAUER breathing air products Distinctive features of BAUER Kompressoren BAUER equals more than 65 years of specialized knowledge and experience BAUER has it

More information

Breathable Compressed Air

Breathable Compressed Air aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Breathable Compressed Air Typical Hazardous Substances Biological agents

More information

Instruction Manual. Pressure Vessels

Instruction Manual. Pressure Vessels Instruction Manual Pressure Vessels acc. to DGRL 97 / 23 / EG Edition December 2006 INSTRUCTION MANUAL FOR PRESSURE VESSELS ACCORDING TO DGRL 97/23/EG Production year: * Pressure vessel production number:

More information

MOBILAIR M 210 / M 235. Portable Compressor With the world-renowned SIGMA PROFILE Flow rate 18.0 to 23.3 m³/min ( cfm) COMPRESSORS

MOBILAIR M 210 / M 235. Portable Compressor With the world-renowned SIGMA PROFILE Flow rate 18.0 to 23.3 m³/min ( cfm) COMPRESSORS COMPRESSORS MOBILAIR M 210 / M 235 Portable Compressor With the world-renowned SIGMA PROFILE Flow rate 18.0 to 23.3 m³/min (640 825 cfm) www.kaeser.com MOBILAIR M 210 / M 235 The powerful combination of

More information

Industrial Compressor

Industrial Compressor Industrial Compressor KOMPRESSOREN RARE GASES Systems Fotos: Ralf Deichelmann HIGH PRESSURE INTEGRATED SYSTEM TECHNOLOGY CUSTOM-BUILT FOR SPECIFIC RARE GAS APPLICATIONS Modern industrial processes require

More information

MOBILAIR M 235. Portable Compressor With the world-renowned SIGMA PROFILE Flow rate 18.1 to 23.3 m³/min ( cfm)

MOBILAIR M 235. Portable Compressor With the world-renowned SIGMA PROFILE Flow rate 18.1 to 23.3 m³/min ( cfm) MOBILAIR M 235 Portable Compressor With the world-renowned SIGMA PROFILE Flow rate 18.1 to 23.3 m³/min (640 825 cfm) www.kaeser.com MOBILAIR M 235 Efficient and durable The powerful combination of the

More information

Niltox Breathing Air Purifier Range

Niltox Breathing Air Purifier Range Breathing Air Requirements The main standards affecting breathing air are BSEN529, EN12021 and COSHH. The requirements for a breathing air system are shown in the table opposite and the requirements for

More information

Workshop Compressors CLASSIC Series

Workshop Compressors CLASSIC Series www.kaeser.com Workshop Compressors CLASSIC Series Displacement: 210 to 40 l/min Pressure: 10 bar What do you expect from your Classic workshop compressor? Quality results can be achieved only by using

More information

KOMPRESSOREN COMPRESSORS KAESER AIR SERVICE Our Services An Overview

KOMPRESSOREN COMPRESSORS KAESER AIR SERVICE Our Services An Overview KOMPRESSOREN Our Services An Overview Fully equipped 100% quality and service One of the key requirements for any compressed air application is maximum compressed air availability. This is achieved however

More information

High Pressure Breathing Air Compressors

High Pressure Breathing Air Compressors High Pressure Breathing Air Compressors [ Full variety for different applications] MSA offers a comprehensive range of high pressure breathing air compressors for both the firefighting and diving market,

More information

GAS FILLING MACHINES PROCESS MONITORING PRESSURE BALANCE

GAS FILLING MACHINES PROCESS MONITORING PRESSURE BALANCE GAS FILLING MACHINES PROCESS MONITORING PRESSURE BALANCE www.helantec.de Gas filling - visibly better! 2 Managing partners Jochen Weiß and Gregor Witrofsky Advantage for you Worldwide, HELANTEC is the

More information

Specialty gases in small cylinders. Combine flexibility and safety with lightweight portability. Specialty gases in small cylinders.

Specialty gases in small cylinders. Combine flexibility and safety with lightweight portability. Specialty gases in small cylinders. Specialty gases in small cylinders Combine flexibility and safety with lightweight portability. Specialty gases in small cylinders. 02 Specialty gases in small cylinders Our specialty gases guarantee precision.

More information

Working in Gas Hazard Areas

Working in Gas Hazard Areas / Health & Safety OPERATIONS STANDARDS Ref.: Aperam Safety ST 012 Working in Gas Hazard Areas Issue: 15.05.2012 Vers.: v0 Rev.: AM Safety ST 012 v1.2 08.05.2012 Working in Gas Hazard Areas Controlled Updated

More information

Cleaning robots for swimming pools - fully automatic, persistent and powerful YOUR PARTNER FOR SWIMMING POOL HYGIENE

Cleaning robots for swimming pools - fully automatic, persistent and powerful YOUR PARTNER FOR SWIMMING POOL HYGIENE Cleaning robots for swimming pools - fully automatic, persistent and powerful YOUR PARTNER FOR SWIMMING POOL HYGIENE PURE CLEANLINESS IMPRESSES. Fun for visitors - reliability for operators MARINER 3S

More information

SOUTH AFRICAN NATIONAL STANDARD

SOUTH AFRICAN NATIONAL STANDARD ISBN 978-0-626-24871-0 SOUTH AFRICAN NATIONAL STANDARD The selection, use and maintenance of respiratory protective equipment Published by SABS Standards Division 1 Dr Lategan Road Groenkloof Private Bag

More information

AN INTRODUCTION TO COMPRESSED AIR QUALITY for BREATHABLE PURPOSES

AN INTRODUCTION TO COMPRESSED AIR QUALITY for BREATHABLE PURPOSES AN INTRODUCTION TO COMPRESSED AIR QUALITY for BREATHABLE PURPOSES 1 of 1 Introduction Supplied air breathing apparatus systems require a breathable compressed air source to feed the equipment. The quality

More information

HiQ laboratory gas generators.

HiQ laboratory gas generators. Product information HiQ laboratory gas generators. The convenient alternative for laboratory environments. 02 HiQ laboratory gas generators HiQ laboratory gas generators. Designed with safety and convenience

More information

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar Instruction manual for high purity gas pigtails 200 bar / 300 bar Contents Contents... 2 1. Preface... 3 1.1 Overview... 3 1.2 General... 3 1.3 Intended use... 4 1.4 Personnel requirements... 4 2. For

More information

AIR QUALITY. Safety is in the Air AVOIDING CARBON MONOXIDE POISONING WHILE SCUBA DIVING

AIR QUALITY. Safety is in the Air AVOIDING CARBON MONOXIDE POISONING WHILE SCUBA DIVING AIR QUALITY Safety is in the Air AVOIDING CARBON MONOXIDE POISONING WHILE SCUBA DIVING INTRODUCTION Carbon monoxide poisoning and its influence on diving safety Carbon monoxide (CO) is an odourless, colourless

More information

Dräger Short-term Tubes Dräger-Tubes

Dräger Short-term Tubes Dräger-Tubes Dräger Short-term Tubes Dräger-Tubes Tried and tested a million times: Worldwide, the Dräger Short-term Tubes have proven to be a very cost-effective and reliable method for the measurement of gases. Decreasing

More information

Workshop Compressors CLASSIC Series

Workshop Compressors CLASSIC Series www.kaeser.com Workshop Compressors CLASSIC Series Displacement: 210 to 40 l/min Pressure: 10 bar What do you expect from your CLASSIC workshop compressor? Quality results can be achieved only by using

More information

INSPECTION OF MEDICINAL GASES

INSPECTION OF MEDICINAL GASES PHARMACEUTICAL INSPECTION CONVENTION PHARMACEUTICAL INSPECTION CO-OPERATION SCHEME PI 025-2 25 September 2007 AIDE-MEMOIRE INSPECTION OF MEDICINAL GASES PIC/S September 2007 Reproduction prohibited for

More information

Breathing Air Purifiers Comply with OSHA Grade D, NFPA-99, European Pharmacopoeia and other International Breathing Air Standards

Breathing Air Purifiers Comply with OSHA Grade D, NFPA-99, European Pharmacopoeia and other International Breathing Air Standards Breathing Air Purifiers Comply with OSHA Grade D, NFPA-99, European Pharmacopoeia and other International Breathing Air Standards www.domnickhunter.com domnick hunter Breathing Air Purifiers provide air

More information

4-7 kw/ hp. Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward

4-7 kw/ hp. Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward GN 4-7 kw/5.5-10 hp Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward Total capability, total responsibility Right at the heart of your business, Atlas Copco delivers quality compressed air

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS euro-gas@btconnect.com www.euro-gasman.com AIRCHECK OPERATING MANUAL By carefully following these instructions, the AIRCHECK with KITAGAWA gas detection tubes will enable you to

More information

www.ompressedairsystems.com ultra-high purity nitrogen generators nitrogen purity: 95% to 99.999% www.ompressedairsystems.com ultra-high purity nitrogen generators nitrogen purity: 95% to 99.999% Leading

More information

Selecting Respirators and Associated Equipment Monthly webinars from AFS- PROPOSED SCHEDULE

Selecting Respirators and Associated Equipment Monthly webinars from AFS- PROPOSED SCHEDULE Selecting Respirators and Associated Equipment Monthly webinars from AFS- PROPOSED SCHEDULE From the April 26, 2018 Webinar- Respiratory Protection and Medical Surveillance for Silica? OSHA s Hierarchy

More information

SMART Explosion. Efficient Boiler Cleaning with Explosion Generators

SMART Explosion. Efficient Boiler Cleaning with Explosion Generators SMART Explosion Efficient Boiler Cleaning with Explosion Generators Problem and Solution The use of solid fuels, such as coal, waste or biomass, is liable to intense fouling of the steam generator heating

More information

TRAINING PROGRAM 2018 BAUER ACADEMY Technical Training

TRAINING PROGRAM 2018 BAUER ACADEMY Technical Training BAUER ACADEMY Technical Training INFORMATIVE CUSTOMER-ORIENTED COMPETENT USEFUL CONTENT Our trainers... 3 General information... 4 Application... 4 Cancellation... 4 Course fees... 5 Partner hotel... 5

More information

RS 2-75 D 109 D RSF 87 D 127 D with direct drive

RS 2-75 D 109 D RSF 87 D 127 D with direct drive Screw compressors RS 2-75 D 109 D RSF 87 D 127 D with direct drive Made in Germany Motor size: 75 127 kw RENNER GmbH Kompressoren Success Rooted in Tradition. RENNER GmbH Kompressoren have been known for

More information

A. Evaluation of the written program

A. Evaluation of the written program A. Evaluation of the written program Begin your audit with an evaluation of the written respiratory protection program. In addition to the operating procedures describing respirator selection and use in

More information

Calibration Requirements for Direct Reading Confined Space Gas Detectors

Calibration Requirements for Direct Reading Confined Space Gas Detectors : Calibration Requirements for Direct Reading Confined Space Gas Detectors However, the definition of bump test has always been a little slippery. Some manufacturers differentiate between a bump test that

More information

Verification Of Calibration for Direct-Reading Portable Gas Monitors

Verification Of Calibration for Direct-Reading Portable Gas Monitors U. S. Department of Labor Occupational Safety and Health Administration Directorate of Science, Technology and Medicine Office of Science and Technology Assessment Verification Of Calibration for Direct-Reading

More information

B-Series. breathing air systems flow capacity: scfm

B-Series. breathing air systems flow capacity: scfm B-Series breathing air systems flow capacity: 14-486 scfm B 1 B-Series breathing air systems flow capacity: 14-486 scfm B 1 Leading edge technology and more than 100 years of experience nano-purification

More information

Dräger Quaestor 7000 Test Equipment

Dräger Quaestor 7000 Test Equipment Dräger Quaestor 7000 Test Equipment All static and dynamic tests of the Dräger Quaestor 7000 are carried out fully automatically. Controlled by the newly developed software, each test is carried out intuitively.

More information

The ultimate powered air purifying respirator

The ultimate powered air purifying respirator The ultimate powered air purifying respirator As you know, many of the demanding jobs that require respiratory protection also require portability. How can you ensure your employees are safe, comfortable

More information

RS D RSF D with direct drive

RS D RSF D with direct drive Screw compressors RS 2-75 109 D RSF 87 127 D with direct drive Made in Germany Motor power: 75 127 kw RENNER GmbH Kompressoren success rooted in tradition. RENNER GmbH Kompressoren have been known for

More information

Good things come in threes

Good things come in threes 3 Hardware for specialty gases Equipment, supply systems and services for specialty gases Good things come in threes 02 Hardware for specialty gases Everything under one roof The complete equipment range

More information

Improve Process Reliability

Improve Process Reliability Convenient Conductivity Calibration to Meet Pharmacopeia Regulations Pharmacopeias require that conductivity measurement systems be periodically calibrated to ensure their precision. The range of accessories

More information

Dräger Aerotest Navy Test Equipment

Dräger Aerotest Navy Test Equipment Dräger Aerotest Navy Test Equipment Specially designed to meet the requirements of the Navy, the Dräger Aerotest Navy is used to monitor the purity of breathing air in the high pressure range. Transport

More information

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology:

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology: Title: Comparison of Chemical Sensor and NDIR Technologies TSN Number: 25 File:\\MII- SRV1\Metron\Bridge_Analyzers\Customer_Service_Documentation\White_Papers\25_G en EGA NDIR vs Chemical Sensor.docx Created

More information

GAS INJECTION TECHNOLOGY GIT

GAS INJECTION TECHNOLOGY GIT GAS INJECTION TECHNOLOGY GIT Innovative and complete solutions ECONOMICAL modular RELIABLE BAUER KOMPRESSOREN offer Gas Injection Technology as a solution to the problems of plastic part production. The

More information

Respiratory Protection

Respiratory Protection Respiratory Protection Purpose The purpose is to establish a set of guidelines for the selection of respiratory protection equipment, situations for its use, and training in the use of the respirator required.

More information

SATA air vision Spray Guns I Cup Systems I Breathing Protection I Air Filtration I Accessories. Focus on breathing protection

SATA air vision Spray Guns I Cup Systems I Breathing Protection I Air Filtration I Accessories. Focus on breathing protection SATA air vision 5000 Spray Guns I Cup Systems I Breathing Protection I Air Filtration I Accessories Focus on breathing protection SATA air vision 5000: Breathing Equipment to Protect Your Health Your employees

More information

Columbus Instruments

Columbus Instruments 0215-003M Portable O 2 /CO 2 /CH 4 Meter User s Manual Columbus Instruments 950 NORTH HAGUE AVENUE TEL:(614) 276-0861 COLUMBUS, OHIO 43204, USA FAX:(614) 276-0529 1 www.colinst.com TOLL FREE 1-800-669-5011

More information

IRwin Methane Leak Detector. Innovation makes the difference

IRwin Methane Leak Detector. Innovation makes the difference IRwin Methane Leak Detector Innovation makes the difference Innovative methane detector system for easy survey of gas pipelines IRwin is a portable methane leak detector for fast and easy survey of gas

More information

Dräger PAS Filter series Airline Equipment

Dräger PAS Filter series Airline Equipment Filter series Airline Equipment The filters reliably clean air, e.g. from an existing highpressure network, from liquid and solid particles, including oil vapour and smell. This not only means that you

More information

Respiratory Protective Equipment

Respiratory Protective Equipment Page 1 of 5 Health and Safety Fact File - Protective Clothing Respiratory Protective Equipment Respiratory protective equipment (RPE) selected for compliance with the COSHH regulations must conform to

More information

Compressed Airline Breathing Apparatus

Compressed Airline Breathing Apparatus Compressed Airline Breathing Apparatus [ The Independence in Breathing] The Complete Range at a Glance Full face mask with lung governed demand valve Light duty airline breathing apparatus Cavair LDA Pressure

More information

Dräger-Tube pump accuro Dräger Tube Pump

Dräger-Tube pump accuro Dräger Tube Pump Dräger-Tube pump accuro Dräger Tube Pump Fast measurement with one hand: The Dräger-Tube pump accuro allows you to use the established Dräger-Tubes to take measurements under extreme conditions. The easy-to-use

More information

RULES FOR CLASSIFICATION Naval vessels. Part 1 Classification and surveys Chapter 5 Surveys for submarines. Edition January 2016 DNV GL AS

RULES FOR CLASSIFICATION Naval vessels. Part 1 Classification and surveys Chapter 5 Surveys for submarines. Edition January 2016 DNV GL AS RULES FOR CLASSIFICATION Naval vessels Edition January 2016 Part 1 Classification and surveys Chapter 5 The content of this service document is the subject of intellectual property rights reserved by ("DNV

More information

Active Fire Prevention by Oxygen Reduction Systems

Active Fire Prevention by Oxygen Reduction Systems Active Fire Prevention by Oxygen Reduction Systems Markus Mueller Wagner Schweiz AG, Wallisellen, Switzerland Abstract After more than 15 years, active fire prevention by Oxygen reduction systems has become

More information

Design. Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing. Working Principle

Design. Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing. Working Principle SB Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing A family of API liquid ring compressors has been developed and has been in the market for nearly a decade, they are specifically made

More information

BREATHING AIR FOR LIFE. DRÄGER COMPRESSORS. Cra 28 No. 71b - 25 / / /

BREATHING AIR FOR LIFE. DRÄGER COMPRESSORS. Cra 28 No. 71b - 25 / /   / BREATHING AIR FOR LIFE. DRÄGER COMPRESSORS DETECTION PERSONAL PROTECTION DIVING TECHNOLOGY SYSTEM TECHNOLOGY SERVICES Dräger Safety compressors a breath of fresh air. BREATHING IS LIFE. FOR MORE THAN A

More information

Stationary High Pressure Compressor for Air and Breathing Air Compression. PE 400-VE in open version

Stationary High Pressure Compressor for Air and Breathing Air Compression. PE 400-VE in open version Technical data sheet Stationary High Pressure Compressor for Air and Breathing Air Compression Types: PE300-VE PE400-VE PE550-VE PE700-VE PE850--VE Production status: F04 PE 400-VE in open version Medium

More information

Aerotest Breathing Air Systems

Aerotest Breathing Air Systems DETECTION PERSONAL PROTECTION DIVING TECHNOLOGY SYSTEM TECHNOLOGY SERVICES Aerotest Breathing Air Systems Since 1937, when we introduced our first detector tube, Draeger has been the world leader in the

More information

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS Precise and Stable SF 6 Gas Analyzer Simultaneous measurement of humidity, SF 6 purity and SO 2 concentration Integrated gas recovery system with automatic pump back Fully automated SF 6 gas testing Fundamental

More information

Title: Standard Operating Procedure for R&R Environmental Devices Model MFC201 Gas Dilution Calibrator

Title: Standard Operating Procedure for R&R Environmental Devices Model MFC201 Gas Dilution Calibrator Procedure No: SOP-029 Revision No: 1.1 (December 29, 2010) Page No.: 1 of 7 1. INTRODUCTION AND SCOPE To obtain timely data for the purpose of air quality assessment, air quality trend reporting, air quality

More information

Unique solutions for Oxygen and Nitrogen supply

Unique solutions for Oxygen and Nitrogen supply Unique solutions for Oxygen and Nitrogen supply SHAPING THE FUTURE Index Competence and Trust 3 Modular PSA 4 Superior PSA generator Technology 5 NOXERIOR Competence and Trust NOXERIOR focuses on all aspects

More information

GMC-I Service GmbH Calibration Center

GMC-I Service GmbH Calibration Center 2016 GMC-I Service GmbH Calibration Center DAkkS, ISO & Factorycalibration www.gmci-service.com From spare parts, reparation, rental service, maintenance of industrial health and safety standards, calibration

More information

Unique solutions for medical oxygen

Unique solutions for medical oxygen Unique solutions for medical oxygen SHAPING THE FUTURE Index Competence and Trust 3 Certified Oxygen 93% Supply 5 OXYSWING Advantages 7 NOXERIOR Competence and Trust NOXERIOR focuses on all aspects of

More information

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Your local gas generation partner. Precision series Modular gas generation solution for GC. Your local gas generation partner Precision series Modular gas generation solution for GC www.peakscientific.com Perform with Precision Specifically designed and engineered for GC laboratory applications,

More information

CALIBRATION SERVICES HUMIDITY DEW POINT AIR VELOCITY MASS FLOW TEMPERATURE CO 2 PRESSURE. (+34)

CALIBRATION SERVICES HUMIDITY DEW POINT AIR VELOCITY MASS FLOW TEMPERATURE CO 2 PRESSURE. (+34) CALIBRATION SERVICES HUMIDITY DEW POINT AIR VELOCITY MASS FLOW TEMPERATURE CO 2 PRESSURE (+34) 968 162 005 www.sensovant.com comercial@sensovant.com www.epluse.com CALIBRATION AT THE HIGHEST LEVEL The

More information

exceeds global breathing air quality standards B 1 breathing air systems flow capacity: scfm flow capacity: scfm ( Nm 3 /hr)

exceeds global breathing air quality standards B 1 breathing air systems flow capacity: scfm flow capacity: scfm ( Nm 3 /hr) exceeds global breathing air quality standards B 1 breathing air systems flow capacity: 6-486 scfm flow capacity: 8-1500 scfm (13-2550 Nm 3 /hr) breathing air systems flow capacity: 6-486 scfm B 1 Leading

More information

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS Annex 3, page 2 ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS The text of existing chapter 15 is replaced by the following: "1 Application This

More information

deltaflowc deltaflowc Venturi or Probe

deltaflowc deltaflowc Venturi or Probe deltaflowc Mass Flowmeter for Gases - Multivariable with ultra fast dp, p and T-sensors - Compact, accurate and user-friendly - Ideal for OEMs deltaflowc Venturi or Probe Precise mass flow metering deltaflowc

More information

Breathing Air Purifiers Comply with European Pharmacopoeia and International Breathing Air Standards ENGINEERING YOUR SUCCESS.

Breathing Air Purifiers Comply with European Pharmacopoeia and International Breathing Air Standards ENGINEERING YOUR SUCCESS. Breathing Air Purifiers Comply with European Pharmacopoeia and International Breathing Air Standards ENGINEERING YOUR SUCCESS. Parker domnick hunter Breathing Air Purifiers provide air 1,000,000 times

More information

HYPOXIC AIR FIRE PREVENTION SYSTEM TECHNICAL SPECIFICATION

HYPOXIC AIR FIRE PREVENTION SYSTEM TECHNICAL SPECIFICATION HYPOXIC AIR FIRE PREVENTION SYSTEM TECHNICAL SPECIFICATION Introduction: Hypoxic Air Fire Prevention System is a revolutionary fire prevention technology. It has the unique ability to create a breathable

More information

20. Semi-Closed Circuit Rebreather Instructor, Unit Specific- DOLPHIN, RAY, Atlantis, SUBMATIX ST100 & AZIMUTH

20. Semi-Closed Circuit Rebreather Instructor, Unit Specific- DOLPHIN, RAY, Atlantis, SUBMATIX ST100 & AZIMUTH 20. Semi-Closed Circuit Rebreather Instructor, Unit Specific- DOLPHIN, RAY, Atlantis, SUBMATIX ST100 & AZIMUTH 20.1 Introduction This is the entry-level certification course for instructors wishing to

More information

ADVANCED AIRLINE FILTER INSTRUCTION MANUAL

ADVANCED AIRLINE FILTER INSTRUCTION MANUAL ADVANCED AIRLINE FILTER INSTRUCTION MANUAL CONTENTS Read all instructions and warnings before using this product. Keep this manual for future reference. INTRODUCTION 3!WARNINGS! 5 BASEMOUNT ASSEMBLY 6

More information

Hauptüberschrift Optionale zweite Zeile

Hauptüberschrift Optionale zweite Zeile Hauptüberschrift Optionale zweite Zeile HEADQUARTERS Dräger Safety AG & Co. KGaA Revalstrasse 1 23560 Lübeck, Germany www.draeger.com 90 46 702 10.08-1 Marketing Communications E7 PR DW 2009 Dräger Safety

More information

Preliminary filter Precision measurement chamber Flow meter Instruction manual

Preliminary filter Precision measurement chamber Flow meter Instruction manual Preliminary filter 0554 3311 Precision measurement chamber 0554 3312 Flow meter 0554 3313 Instruction manual en 2 Safety and the environment Safety and the environment About this document Please read this

More information

Optimization of a Proven Technology

Optimization of a Proven Technology Optimization of a Proven Technology Second Generation closed-circuit breathing apparatus Symbiose The new BG 4 closed-circuit breathing apparatus is a symbiosis of reliable Dräger technology and practical

More information

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar EN - english Instructions for installation and operation Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar Dear customer, Thank you for deciding in favour of the METPOINT

More information

Product Range. High performance and economic high pressure solutions Made in Germany

Product Range.  High performance and economic high pressure solutions Made in Germany Product Range Purification Storage Filling Panels Nitrox/Trimix High performance and economic high pressure solutions Made in Germany www.lw-compressors.com 2 Lenhardt & Wagner Solid Growth Lenhardt &

More information

MMS Mercury Monitoring System for Natural Gas

MMS Mercury Monitoring System for Natural Gas MMS Mercury Monitoring System for Natural Gas Natural gas often contains mercury at concentrations that vary from below 1 to above 10000 µg/m 3. Mercury is both toxic and potentially damaging: it can corrode

More information

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100 Information Sheet PlasmaPro Estrelas100 About this information sheet This data sheet provides basic information about the installation of a PlasmaPro Estrelas100 tool. Some of the information in this sheet

More information

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions. Oxford Instruments Plasma Technology www.oxford-instruments.com About this data sheet This data sheet provides basic information about the installation of a tool. Floor and wall loadings Table 1 lists

More information

Dräger ABIL-L Airline Equipment

Dräger ABIL-L Airline Equipment Dräger ABIL-L Airline Equipment Simple, but effective protection: the compressed airline system ABIL- L offers comfortable respiratory protection during long-term stationary applications. ST-806-2008 02

More information

1 Exam Prep NFPA 99 Health Care Facilities Questions and Answers (Plumbing Contractor)

1 Exam Prep NFPA 99 Health Care Facilities Questions and Answers (Plumbing Contractor) 1 Exam Prep NFPA 99 Health Care Facilities Questions and Answers (Plumbing Contractor) 1. According to NFPA 99, SCFM is an acronym for. a) Surface Conditions at Fahrenheit Mercury b) Standard Conditions

More information

Operating Instructions. Ball valve fitting according to ZB For pressure transmitter VEGABAR 82. Document ID: 50027

Operating Instructions. Ball valve fitting according to ZB For pressure transmitter VEGABAR 82. Document ID: 50027 Operating Instructions Ball valve fitting according to ZB 2553 For pressure transmitter VEGABAR 82 Document ID: 50027 Contents Contents 1 About this document 1.1 Function... 3 1.2 Target group... 3 1.3

More information

Your Health is our Concern

Your Health is our Concern Professional Breathing Protection Equipment Spray Guns I Cup Systems I Breathing Protection I Air Filtration I Accessories Your Health is our Concern Breathing Equipment to Protect Your Health SATA breathing

More information