The relationship of pressure and aqueous outflow in enucleated human eyes*

Size: px
Start display at page:

Download "The relationship of pressure and aqueous outflow in enucleated human eyes*"

Transcription

1 The relationship of pressure and aqueous outflow in enucleated human eyes* Bruce A. Ellingsen and W. Morton Grant The influence of intraocular pressure on resistance to aqueous outflow was evaluated in enucleated normal and glaucomatous human eyes by quantitative aqueous perfusion of the anterior chamber. When provision was made for free communication from anterior to posterior chamber to avoid artificial deepening of the anterior chamber, and the intraocular pressure was raised stepwise from 5 to 50 mm. Hg, the resistance to outflow progressively increased. The resistance to outflow increased more steeply in eyes with open-angle glaucoma than in nonglaucomatous eyes. When no communication was provided for flow of perfusion fluid from anterior to posterior chamber, and the pressure was raised in the same manner, the anterior chamber progressively deepened, but above 20 mm. Hg the resistance to outflow became nearly independent of intraocular pressure. Effects of reducing intraocular pressure, repeating perfusions, prolonging perfusions, and modifying the perfusion fluid were also evaluated. We postulate that intraocular pressure has direct influence on aqueous outflow channels. In openangle glaucomatous eyes the aqueous outflow channels appear to be abnormally susceptible to this influence. Key words: intraocular pressure, outflow facility, outflow resistance, enucleated eyes, aqueous perfusion, glaucoma. hen the aqueous outflow characteristics of the eye are being evaluated and analyzed clinically or experimentally it is important to examine and take into account the influence of intraocular pressure on From the Howe Laboratory of Ophthalmology, Harvard Medical School, and the Massachusetts Eye and Ear Infirmary, Boston, Mass. This investigation was supported by National Institutes of Health Center Grant 5-PO1-EY00292 and National Institutes of Health Research grant 5-RO1-EY00002 from the National Eye Institute. Manuscript submitted March 22, 1971; manuscript accepted April 30, Reprint requests: Dr. Bruce A. Ellingsen, Spokane Eye Clinic, S. 427 Bernard St., Spokane, Wash "Presented at the ARVO meeting Sarasota, Fla., May, resistance to outflow of aqueous humor. This deserves attention, for instance, in analysis of individual and consecutive Schi0tz tonographies in which the basic assumption generally has been made, but not conclusively validated, that outflow resistance remains constant at different pressures. Similarly, possible changes in resistance to outflow secondary to changes in pressure need to be considered in evaluating perfusion methods used for estimating outflow resistance, aqueous formation, and pseudofacility. Several investigators have concluded from studies in vivo and in vitro that outflow resistance of primate eyes may not be affected by variation in pressure within physiologic intraocular pressure ranges, 1 " 3 whereas others have reported that outflow

2 Volume 10 Number 6 10? and resistance to aqueous outflow 431 resistance may be increased by increasing intraocular pressure. 4 " 7 The suggestion also has been made that an increase in resistance with increased pressure is a property of the living eye and reflects certain unspecified homeostatic mechanisms that are not operative in the enucleated eye. 8 The present series of experiments was undertaken to establish the facts more definitely if possible, and to re-examine some of the factors that affect the pressure-outflow relationship in normal and glaucomatous eyes. Methods Measurements were made on enucleated normal and glaucomatous human eyes by means of a modification of the constant pressure perfusion technique of Barany. 9 Except for five eyes which have been clearly identified as glaucomatous, the eyes which were used had no history of glaucoma, and examination of the anterior segment using an operating microscope revealed no abnormalities. The glaucomatous eyes had been diagnosed clinically as having primary open-angle glaucoma, which was under treatment with various medications at the time of death. All eyes were obtained post mortem and stored at 4 C. in a moist environment until approximately one-half hour prior to perfusion. Perfusions were started 4 to 58 hours post mortem and were carried out at room temperature. The eyes were routinely set or encased in silicone rubber, enveloping the posterior segment to just anterior to the equator. The encased eye was mounted on an adjustable ball-bearing fitting which allowed easy manipulation of the preparation. Exposed episclera and conjunctiva were covered with strips of tissue paper saturated with perfusing solution. Control eyes perfused without encasement in silicone rubber gave results that were not appreciably different from those obtained with encasement. The constant pressure perfusion technique of Barany was selected after trial and comparison of other established methods, because it offers the advantage of requiring a very short time to achieve a steady state, and this facilitates multiple determinations of outflow facility. The eyes were perfused through either a previously described corneal fitting 10 or a 23 gauge needle. The fitting or needle was attached to polyethylene tubing connecting to a reservoir. The height of the reservoir was adjustable and its weight was constantly monitored with an electric strain gauge and recorder. A radial iridotomy was performed prior to perfusion, or perfusion was accomplished through a needle with its tip located specifically in either the posterior chamber or the anterior chamber, depending upon the purpose of the experiment. The perfusing solution in most experiments was a sterile phosphate-buffered, balanced salt solution containing glucose as previously described by Barany, 11 passed through a micropore filter before using. In certain experiments, sterile unbuffered 0.9 per cent sodium chloride solution commercially prepared without preservative for intravenous administration was used for comparison. Results -flow relationship. In 32 normal and 5 glaucomatous eyes multiple determinations of outflow facility were made at specific pressures increasing step wise from 5 to 50 mm. Hg. Then multiple determinations were made in the reverse order with decreasing pressures. An attempt was made to maintain uniform periods of perfusion. The usual time allowed for reaching steady conditions and for measurement of flow at each pressure was 4 to 5 minutes, although occasionally technical diflbculty necessitated somewhat longer perfusion times. When pressure was reduced to 5 or 10 mm. Hg, 7 to 8 minutes were required to reach steady conditions. Determinations of the average pressureoutflow relationship in normal eyes (Fig. 1) indicated a curvilinear relationship in which facility of outflow decreased, or resistance increased, with increasing pressure. With decreasing pressure a fairly straight line relationship was found, and facility of outflow was more nearly constant, except for a small decrease in facility between 50 and 40 mm. Hg and a larger decrease between 10 and 5 mm. Hg. Outflow facility calculated for increasing pressure (Table I) through the range from 5 to 50 mm. Hg decreased progressively from 0.42 to 0.16 ju,l per minute per millimeter of mercury. The percentage change in total facility per millimeter of mercury of pressure between various pressure levels (listed in Table I) decreased with increasing pressure. To determine more about what happened to outflow at very low pressures, seven eyes were perfused at pressures be-

3 432 Ellingsen and Grant Investigative Ophthalmology June mmhg 2 SD. below normal Open angle glaucoma Fig. 1. Data from enucleated human eyes in which anterior and posterior chambers were in free communication, and aqueous perfusion flow rates were measured at a series of steady states as the intraocular pressure was raised stepwise to 50 mm. Hg, and again as the pressure was reduced (as indicated by the arrows). The upper loop of solid lines represents mean values from 32 normal eyes and the lower loop of solid lines represents 5 open-angle glaucomatous eyes. The dashed line represents values calculated as 2 S.D. below the means of the normal eyes. tween 0 and 5 mm. Hg. This showed that as pressure was raised from 0 the onset of flow began between 0.5 and 2 mm. Hg, and that with decreasing pressure the flow ceased between 5 and 3 mm. Hg. The glaucomatous eyes differed from the normal in that at low pressure the initial values of outflow facility were lower than normal and that as pressure was raised between 10 and 30 mm. Hg the rate of decrease in facility was greater than normal (Table II). At 20 mm. Hg and at higher pressures the mean outflow rates of glaucomatous eyes were calculated to be less than the mean of normal eyes by more than two standard deviations (Fig. 1). At lower pressures the means of the facility measurements of the glaucomatous and the normal differed less than this. 50 It is noteworthy that a similar abnormally steep increase of resistance to outflow with elevated pressure in glaucomatous eyes has been reported by Kleinert 5 from perfusion measurements on a series of patients. Successive determinations of pressureflow relationship. Four eyes were perfused two or more times up and down the pressure range in order to determine the response of eyes subjected to successive determinations of the pressure-flow relationship. Between successive determinations the eyes were allowed to remain at reduced pressure with no inflow for 10 to 20 minutes. Results suggest that under these conditions there is a tendency during the rest period for restoration of outflow facility that had become reduced during elevation of pressure. The characteristic form of the pressure-flow relationship is maintained, but with facility values at most pressures 30 to 40 per cent below those of the initial determination (Table III). Also, in this experiment in successive cycles the facility of outflow became higher at 10 mm. Hg than at 5 mm. Hg, in contrast to the initial determination. Effect of anterior-posterior chamber communication. In order to determine the effect of establishing a communication between anterior and posterior chamber, one glaucomatous and six normal eyes were perfused with and without a communication between anterior and posterior chamber. In one group of four normal eyes and one glaucomatous eye the initial perfusion measurements were made with flow into the anterior chamber and no artificial communication with the posterior chamber. Comparative measurements were then made after establishing communication between the two chambers by means of a radial iridotomy, or by placing a small polyethylene tube under the pupillary margin, or by placing the tip of the perfusing needle in the posterior chamber. In two other normal eyes the initial perfusion was done with the anterior-posterior chamber communication already established,

4 Volume 10 Number 6 IOP and resistance to aqueous outflow 433 Table I. Outflow facility (mean of 32 normal eyes) at each pressure level, reading left to right Facility Per cent facility change (per mm. Hg) \ Table II. Outflow facility (mean of 5 open-angle glaucomatous eyes) at each pressure level Facility Per cent facility change (per mm. Hg) JO Table III. Outflow facility (mean of 4 normal eyes) at each pressure level going up and down the pressure cycle of 5 to 50 mm. Hg the first time and the second time Facility first Facility second Per cent decrease and the subsequent comparative perfusion was done after the iris was allowed to go back into place against the lens. When the perfusion fluid was introduced into the anterior chamber without a communication from anterior to posterior chamber, an artificial deepening of the anterior chamber was easily observable with an operating microscope as the pressure was raised. The change in depth was most conspicuous in the lower portion of the pressure range. When a communication from anterior to posterior chamber was provided, or when the perfusing needle was introduced into the posterior chamber, the anterior chamber did not deepen appreciably as pressure was raised. In Fig. 2, the mean pressure-flow relationships with and without anterior-posterior chamber communications are plotted. It is evident that with no communication, and with the anterior chamber becoming deepened as the pressure increased, the facility of outflow remained essentially constant above 20 mm. Hg (Table IV). When a communication was established avoiding the deepening of anterior chamber, the facility of outflow decreased as the pressure was raised. With decreasing pressure, when there is no anterior-posterior communication, there appears to be a tendency for outflow facility to decrease (Table IV). The one glaucomatous eye perfused as described above reacted like the normal eyes, but facility values were lower than normal. Prolonged perfusion time. In six normal eyes the effect of prolonging perfusion was examined by determining perfusion flow rates every 10 minutes during a period of 40 minutes at pressures maintained at 10,

5 434 Ellingsen and Grant Investigative Ophthalmology June 1971 I I8r Without 10 O O With mmhg Fig. 2. Mean values from enucleated human eyes in which steady-state rates of perfusion of the anterior chamber were determined at ascending and descending intraocular pressures, either as in Fig. 1 with free communication between anterior and posterior chambers to minimize variations in depth of the anterior chamber (lower loop), or without this communication, leaving the lens-iris diaphragm intact so that the anterior chamber deepened automatically as the pressure in the anterior chamber was raised (upper loop). 20, and 30 mm. Hg. At each pressure the outflow facility was found to decrease slowly but continuously during the extended perfusions (Table V). This effect was particularly notable at the lower pressures. Most of the decrease of outflow facility occurred during the first two or three measurements. When the pressure was reduced stepwise through the same range the facility values were more constant during the extended periods of perfusion. When pressure was reduced to 10 mm. Hg, facility tended to increase during the period of perfusion. Comparison of Bdrdny's solution and normal saline. In order to determine if the outflow resistance characteristics of enucleated eyes might be affected by using a different perfusion solution, five pairs of normal eyes were perfused between 5 and 50 mm. Hg with the use of unbuffered 0.9 per cent sodium chloride in one eye of each pair, and solution in the other eye. In another five pairs these solutions were compared according to the prolonged perfusion protocol. Although differences were slight, the results indicate that the outflow facility was more affected by increase of pressure and prolonged perfusion with sodium chloride than with solution (Tables VI and VII). Discussion In considering the results obtained from a conventional perfusion technique, as used in these experiments, it must be kept in mind that the flow actually measured is inflow rather than outflow. Also, when facility of outflow is calculated from rate of inflow at a steady pressure, it is assumed that the intraocular volume is constant during the measurements. Enucleated eyes have an advantage of eliminating from consideration the variations of intraocular volume that are associated in vivo with aqueous formation and with blood flow, but enucleated eyes are not free from a volume variable which is associated with the viscoelastic properties of the eye. Unfortunately, the published data that are available concerning the slow creep or plastic properties of the eye do not provide a quantitative assessment directly applicable to the conditions of the present perfusion studies. 12 However, we estimate from the data that are available that the increase of volume which may be occurring from very slow stretching of the eye during the 4 or 5 minutes involved in measurements of flow would probably account for only a fraction of the calculated variations

6 Volume 10 Number 6 IOP and resistance to aqueous outflow 435 Table IV. Outflow facility (mean of 6 normal eyes) at each pressure level during cycles with and without free communication from anterior to posterior chamber Facility with communication Facility without communication Per cent increase Table V. Outflow facility (mean of 6 normal eyes), changing with time of perfusion, at each pressure level Facility, 10 mm. Hg Facility, 20 mm. Hg Facility, 30 mm. Hg Facility, 20 mm. Hg Facility, 10 mm. Hg Time (min.) Change (%) in outflow facility. Furthermore, it seems to us that difference in creep would be hard to imagine as a factor in explaining the fundamental difference in pressure-flow relationship with and without deepening of the anterior chamber. Osmotic movement of water through the cornea and sclera presumably was a negligible factor in these experiments, since the outer surfaces of the eyes were bathed with the same solutions as used for the perfusions. We have considered the question of whether flow characteristics of geometrically rigid or fixed outflow channels could account for pressure-flow relationships indicated by our experiments. According to advisors in fluid mechanics from the Massachusetts Institute of Technology, the fluid viscosity, flow rates, and approximate dimensions of the outflow system are such as to give a Reynolds number of sufficiently low order that one should expect inertia-free outflow in the human eye. With inertia-free flow in a geometricallyfixed system the resistance to flow (i.e., ratio of driving pressure difference to flow) is constant and independent of flow or pressure. 13 In the human eye it appears, therefore, that to account for the increase in resistance found experimentally the outflow system must not be geometrically fixed and it must be altered physically by increasing flow and pressure. The relative constancy of resistance with decreasing pressure suggests that the postulated physical alteration is not immediately reversible by reducing pressure for a prolonged period. It appears that artificial deepening of the anterior chamber tends to counteract the influence of increasing flow and pressure and to stabilize the outflow system physically. An obvious explanation would be that the forcible retrodisplacement of lens-iris diaphragm tends to stabilize facility of outflow by its traction on scleral spur and trabecular meshwork, while intraocular pressure acting directly upon the aqueous outflow channel tends to reduce facility of outflow in the absence of this stabilizing force. When we think about the mechanism by which intraocular pressure and aqueous outflow may directly alter the resistance to flow through the outflow system our attention is drawn to Schlemm's canal,

7 436 Ellingsen and Grant Investigative Ophthalmology June 1971 Table VI. Outflow facility (means of 5 pairs of normal eyes) at each pressure level, with solution in one eye of each pair and 0.9 per cent sodium chloride solution in the other Facility, Facility, saline Per cent different from Table VII. Outflow facility (mean of 5 pairs of normal eyes) at each pressure level and for different times of perfusion, with solution in one eye of each pair and 0.9 per cent sodium chloride solution in the other 0 Time 10 (min.) Change (%) Facility, 10 mm. Hg Facility, 20 mm. Hg Facility, 30 mm. Hg Facility, 20 mm. Hg Facility, 10 mm. Hg particularly the inner wall, and to its relationship to trabecular meshwork and the outer wall of Schlemm's canal, as a conceivable site for compression or geometric alteration, but at this time we can only speculate. At the same time it is tempting to speculate that the site or mechanism of abnormal resistance to outflow in glaucomatous eyes may be the same location as the compression and variable resistance mechanism since the perfusions of glaucomatous eyes have indicated that they differed not only in having an abnormally high resistance to outflow but also in responding with abnormally steep increase of resistance to elevated pressure. In design of perfusion experiments it appears from our findings that among the factors deserving attention are anteriorposterior chamber communication, level of intraocular pressure, direction of change of pressure, duration of perfusion, and type of perfusing solution, since each of these may influence experimental results. The experiments were carried out in the Howe Laboratory of Ophthalmology of Harvard Medical School at the Massachusetts Eye and Ear Infirmary. REFERENCES 1. Grant, W. M.: Tonographic method for measuring the facility and rate of aqueous flow in human eyes, Arch. Ophthal. 44: 204, Becker, B., and Constant, M.: The facility of aqueous outflow, Arch. Ophthal. 55: 305, Bill, A., and Barany, E.: Gross facility, facility of conventional routes and pseudo facility of aqueous humor outflow in the Cynomolgus monkey, Arch. Ophthal. 75: 665, 1966.

8 Volume 10 Number 6 IOP and resistance to aqueous outflow Frangois, J., Rabaey, M., Neetens, A., and Evens, L.: Further perfusion studies on the outflow of aqueous humor in human eyes, Arch. Ophthal. 59: 683, Kleinert, H.: Abflussdruck und Abflusswiderstand, Ber. Dtsch. Ophthal. Ges. 64: 57, Nihard, P.: Influence de la pression oculaire sur la resistance a l'ecoulement de l'humeur aqueuse, Acta Ophthal. (Kbh.) 40: 12, Levene, R., and Hyman, B.: The effect of intraocular pressure of the facility of outflow, Exp. Eye Res. 8: 116, Langham, M.: Manometric, pressure cup and tonographic procedures in the evaluation of intraocular dynamics, in Leydhecker, W., editor: Glaucoma: Tutzing symposium, Basel, 1967, Karger AG. 9. Barany, E. H.: The mode of action of pilocarpine on outflow resistance in the eye of a primate (Cercopithicus ethiops), INVEST. OPHTHAL. 1: 712, Grant, W. M.: Further studies on facility of flow through trabecular meshwork, Arch. Ophthal. 60: 523, Barany, E. H.: Simultaneous measurement of changing intraocular pressure and outflow facility in the vervet monkey by constant pressure infusion, INVEST. OPHTHAL. 3: 135, McEwen, W. K.: Difficulties in measuring ocular pressure and ocular rigidity, in Leydhecker, U., editor: Glaucoma: Tutzing symposium, Basel, 1967, Karger, AG. 13. Shapiro, A. H.: Personal communication, 1970.

I t is generally accepted that the hydraulic

I t is generally accepted that the hydraulic The effect of intraocular pressure on conventional outflow resistance in the enucleated human eye Richard F. Brubaker A technique for measuring resistance to outflow in enucleated eyes is described. The

More information

Outflow Characteristics of Isolated Anterior Segments of Human Eyes

Outflow Characteristics of Isolated Anterior Segments of Human Eyes Outflow Characteristics of Isolated Anterior Segments of Human Eyes Berlinde G. Dijkstra,* Jan M. Ruijter,\ and Philip F. Hoyng* Purpose. To evaluate the relationship between intraocular pressure (IOP)

More information

RECORDINGS OF APPLANATING FORCE AT CONSTANT INTRAOCULAR PRESSURE Development of a new technique and results obtained from a study of human eyes.

RECORDINGS OF APPLANATING FORCE AT CONSTANT INTRAOCULAR PRESSURE Development of a new technique and results obtained from a study of human eyes. RECORDINGS OF APPLANATING FORCE AT CONSTANT INTRAOCULAR PRESSURE Development of a new technique and results obtained from a study of human eyes. AKADEMISK AVHANDLING som med vederbörligt tillstånd av Medicinska

More information

COMPARISON OF PERILIMBAL SUCTION CUP ANALYSIS

COMPARISON OF PERILIMBAL SUCTION CUP ANALYSIS Brit. J. Ophthal. (1966) 50, 12 COMPARISON OF PERILIMBAL SUCTION CUP ANALYSIS AND TONOGRAPHY IN THE DIAGNOSIS OF GLAUCOMA* BY P. A. MAcFAUL Department of Experimental Ophthalmology, Institute of Ophthalmology,

More information

The effect of external compression of the eye on intraocular pressure

The effect of external compression of the eye on intraocular pressure -ff r r JL. The effect of external compression of the eye on intraocular pressure I. Its variations with magnitude of compression and with age Mansour F. Armaly and Adrian H. Halasa i $ V' y. A The effect

More information

Pressure and Flow Characteristics of Ocular Viscoelastic and Silicone Oil Through Glaucoma Drainage Devices

Pressure and Flow Characteristics of Ocular Viscoelastic and Silicone Oil Through Glaucoma Drainage Devices Pressure and Flow Characteristics of Ocular Viscoelastic and Silicone Oil Through Glaucoma Drainage Devices Reid Mollman, MD Table Rock Regional Roundup 9/29/2017 Disclosures None of the participants in

More information

(fig. 3) must be at the same temperature as the water in this chamber CALORIMETRIC STUDIES OF THE EXTREMITIES

(fig. 3) must be at the same temperature as the water in this chamber CALORIMETRIC STUDIES OF THE EXTREMITIES CALORIMETRIC STUDIES OF THE EXTREMITIES II. EXPERIMENTAL APPARATUS AND PROCEDURES' By ROY KEGERREIS (Received for publication July 1, 1926) The calorimeter used in these experiments is a modification of

More information

Original Articles. The filtration coefficient of the intraocular vasculature as measured by low-pressure perfusion in a primate eye

Original Articles. The filtration coefficient of the intraocular vasculature as measured by low-pressure perfusion in a primate eye Original Articles The filtration coefficient of the intraocular vasculature as measured by low-pressure perfusion in a primate eye Richard F. Brubaker and David M. Worthen Anterior chamber perfusion of

More information

Studies on the ocular pressure-volume

Studies on the ocular pressure-volume Doppler measurement of vortex vein blood flow in animals William A. Schlegel and Carteret Lawrence The blood flow teas measured continuously in the intact vortex vein of the anesthetized rabbit using an

More information

Effects of Hydrogen Peroxide-Induced Oxidative Damage on Outflow Facility and Washout in Pig Eyes

Effects of Hydrogen Peroxide-Induced Oxidative Damage on Outflow Facility and Washout in Pig Eyes Investigative Ophthalmology & Visual Science, Vol. 32, No. 9, August 1991 Copyright Association for Research in Vision and Ophthalmology Effects of Hydrogen Peroxide-Induced Oxidative Damage on Outflow

More information

The relationship between pressure and volume changes in living and dead rabbit eyes. John E. Eisenlohr and Maurice E. Langham

The relationship between pressure and volume changes in living and dead rabbit eyes. John E. Eisenlohr and Maurice E. Langham The relationship between pressure and volume changes in living and dead rabbit eyes John E. Eisenlohr and Maurice E. Langham A study has been made of the relationship between the volume of fluid infused

More information

OPESAVER Super Irrigation System

OPESAVER Super Irrigation System OPESAVER Super Irrigation System Makoto Kishimoto, MD Dokkyo University School of Medicine Kishimoto Eye Clinic Moriyama City Shiga, Japan n ABSTRACT OPESERVER reduces the surge phenomenon during ultrasonic

More information

plethysmographic methods that when the subject was pinched on the upper

plethysmographic methods that when the subject was pinched on the upper 24 J. Physiol. (I95I) II2, 24-2I 6I2.I5.6II.976 THE DECREASE IN HAND BLOOD FLOW FOLLOWING INFLATION OF AN ARTERIAL OCCLUSION CUFF ON THE OPPOSITE ARM BY IAN C. RODDIE From the Department of Physiology,

More information

OPHTHALMOLOGY THE BRITISH JOURNAL APRIL, 1925 COMMUNICATIONS TONOMETRY* SCHI6TZ. OPHTHALMOLOGY for May and June, 1920, I gave an account

OPHTHALMOLOGY THE BRITISH JOURNAL APRIL, 1925 COMMUNICATIONS TONOMETRY* SCHI6TZ. OPHTHALMOLOGY for May and June, 1920, I gave an account THE BRITISH JOURNAL OF OPHTHALMOLOGY APRIL, 1925 COMMUNICATIONS TONOMETRY* BY PROFESSOR Hj. OSLO, NORWAY SCHI6TZ Fresh Corrected Graphs IN my previous treatise on tonometry in THE BRITISH JOURNAL OF OPHTHALMOLOGY

More information

A mathematical formulation of intraocular pressure as dependent on secretion, ultrafiltration, bulk outflow, and osmotic reabsorption of fluid

A mathematical formulation of intraocular pressure as dependent on secretion, ultrafiltration, bulk outflow, and osmotic reabsorption of fluid A mathematical formulation of intraocular pressure as dependent on secretion, ultrafiltration, bulk outflow, and osmotic reabsorption of fluid Ernst H. Bdrdny An equation has been derived under simplified

More information

IN experimental plant physiology the problem of the control of

IN experimental plant physiology the problem of the control of [ 119 ] THE CONTROL OF ATMOSPHERIC HUMIDITY IN A CLOSED SYSTEM BY B. D. BOLAS From the Department of Plant Physiology and Pathology, Imperial College of Science and Technology, London (With 4 figures in

More information

CALIBRATION OF TONOMETERS*

CALIBRATION OF TONOMETERS* Brit. J. Ophthal. (1955) 39, 368. CALIBRATION OF TONOMETERS* BY C. R. S. J-ACKSONt Edinburgh THE steps which led to the current attempt to introduce standardized tonometers into the United Kingdom have

More information

At increased atmospheric pressure, Praetorius

At increased atmospheric pressure, Praetorius Oxygen lowers intraocular pressure Pamela F. Gallin-Cohen, Steven M. Podos, and Michael E. Yablonski A significant decrease in intraocular pressure was demonstrated in 14 patients as atmospheric pressure

More information

TECHNICAL BULLETIN. TriControls. Control Materials for Liquid QC and Calibration Verification

TECHNICAL BULLETIN. TriControls. Control Materials for Liquid QC and Calibration Verification i-stat TECHNICAL BULLETIN Tris Materials for Liquid QC and OVERVIEW As part of the READi initiative (Responds, Enhances, And Delivers innovations), Abbott Point of Care (APOC) has released a new set of

More information

International Council of Ophthalmology s Ophthalmology Surgical Competency Assessment Rubric (ICO-OSCAR) ICO-OSCAR Instructor Directions

International Council of Ophthalmology s Ophthalmology Surgical Competency Assessment Rubric (ICO-OSCAR) ICO-OSCAR Instructor Directions International Council of Ophthalmology s Ophthalmology Surgical Competency Assessment Rubric (ICO-OSCAR) The International Council of Ophthalmology s Ophthalmology Surgical Competency Assessment Rubrics

More information

INTERACTION BETWEEN WIND-DRIVEN AND BUOYANCY-DRIVEN NATURAL VENTILATION Bo Wang, Foster and Partners, London, UK

INTERACTION BETWEEN WIND-DRIVEN AND BUOYANCY-DRIVEN NATURAL VENTILATION Bo Wang, Foster and Partners, London, UK INTERACTION BETWEEN WIND-DRIVEN AND BUOYANCY-DRIVEN NATURAL VENTILATION Bo Wang, Foster and Partners, London, UK ABSTRACT Ventilation stacks are becoming increasingly common in the design of naturally

More information

COMBINED SCIENCE 0653/6 CO-ORDINATED SCIENCES 0654/6

COMBINED SCIENCE 0653/6 CO-ORDINATED SCIENCES 0654/6 Centre Number Candidate Number Candidate Name International General Certificate of Secondary Education UNIVERSITY OF CAMBRIDGE LOCAL EXAMINATIONS SYNDICATE COMBINED SCIENCE 0653/6 CO-ORDINATED SCIENCES

More information

Process Dynamics, Operations, and Control Lecture Notes - 20

Process Dynamics, Operations, and Control Lecture Notes - 20 Lesson 0. Control valves 0.0 Context Controller output is a signal that varies between 0 and 100%. Putting this signal to use requires a final control element, a device that responds to the controller

More information

CORESTA RECOMMENDED METHOD N 6

CORESTA RECOMMENDED METHOD N 6 CORESTA RECOMMENDED METHOD N 6 DETERMINATION OF VENTILATION DEFINITIONS AND MEASUREMENT PRINCIPLES (2015 Revision September 2016) 1. SCOPE This CORESTA Recommended Method specifies a method for the determination

More information

Analysis of the Interrelationship Among Traffic Flow Conditions, Driving Behavior, and Degree of Driver s Satisfaction on Rural Motorways

Analysis of the Interrelationship Among Traffic Flow Conditions, Driving Behavior, and Degree of Driver s Satisfaction on Rural Motorways Analysis of the Interrelationship Among Traffic Flow Conditions, Driving Behavior, and Degree of Driver s Satisfaction on Rural Motorways HIDEKI NAKAMURA Associate Professor, Nagoya University, Department

More information

Wind Flow Validation Summary

Wind Flow Validation Summary IBHS Research Center Validation of Wind Capabilities The Insurance Institute for Business & Home Safety (IBHS) Research Center full-scale test facility provides opportunities to simulate natural wind conditions

More information

23 RD INTERNATIONAL SYMPOSIUM ON BALLISTICS TARRAGONA, SPAIN APRIL 2007

23 RD INTERNATIONAL SYMPOSIUM ON BALLISTICS TARRAGONA, SPAIN APRIL 2007 23 RD INTERNATIONAL SYMPOSIUM ON BALLISTICS TARRAGONA, SPAIN 16-20 APRIL 2007 AN INVESTIGATION INTO THE INTERRELATION BETWEEN THE INTERNAL AND EXTERNAL BALLISTICS OF FIRING A TP-T TANK AMMUNITION M. H.

More information

Gundersen, 1939), however, it seems unlikely that the limbal circulation. Columbia, Missouri 65201, U.S.A. (Received 25 March 1976)

Gundersen, 1939), however, it seems unlikely that the limbal circulation. Columbia, Missouri 65201, U.S.A. (Received 25 March 1976) J. Phyaiol. (1977), 270, pp. 1-8 1 With 2 text-figure8 Printed in Great Britain DIFFUSION OF OXYGEN AT THE ENDOTHELIAL SURFACE OF THE RABBIT CORNEA BY R. E. BARR, M. HENNESSEY* AND V. G. MURPHYt From the

More information

An investigation of kinematic and kinetic variables for the description of prosthetic gait using the ENOCH system

An investigation of kinematic and kinetic variables for the description of prosthetic gait using the ENOCH system An investigation of kinematic and kinetic variables for the description of prosthetic gait using the ENOCH system K. OBERG and H. LANSHAMMAR* Amputee Training and Research Unit, University Hospital, Fack,

More information

Journal of Applied Fluid Transients, Vol 1-1, April 2014 (3-1)

Journal of Applied Fluid Transients, Vol 1-1, April 2014 (3-1) Modeling and Field Verification Study of Air Slam Conditions on kalanit Pipeline System By Yiftach Brunner & Sathish Kumar ir valves are integral part of long water transmission mains and are essential

More information

Core practical 14: Investigate the relationship between the pressure and volume of a gas at fixed temperature

Core practical 14: Investigate the relationship between the pressure and volume of a gas at fixed temperature Core practical 14 Teacher sheet pressure To measure the volume of a gas at constant temperature but varying pressure Specification links Students should carry out this work with due attention to safety

More information

Retinal vascular response to breathing increased carbon dioxide and oxygen concentrations. Regina Frayser and John B. Hickam

Retinal vascular response to breathing increased carbon dioxide and oxygen concentrations. Regina Frayser and John B. Hickam Retinal vascular response to breathing increased carbon dioxide and oxygen concentrations Regina Frayser and John B. Hickam The retina has a high rate of oxygen consumption, and the retinal vessels are

More information

Lesson 6: Flow Control Valves

Lesson 6: Flow Control Valves : Flow Control Valves Basic Hydraulic Systems Hydraulic Fluids Hydraulic Tank Hydraulic Pumps and Motors Pressure Control Valves Directional Control Valves Flow Control Valves Cylinders : Flow Control

More information

Applying Hooke s Law to Multiple Bungee Cords. Introduction

Applying Hooke s Law to Multiple Bungee Cords. Introduction Applying Hooke s Law to Multiple Bungee Cords Introduction Hooke s Law declares that the force exerted on a spring is proportional to the amount of stretch or compression on the spring, is always directed

More information

THE literature on this subject, which was reviewed recently (CAMPBELL, doses of amytal, and in addition received A.C.E. mixture during the

THE literature on this subject, which was reviewed recently (CAMPBELL, doses of amytal, and in addition received A.C.E. mixture during the -~~ -v GAS TENSIONS IN THE MUCOUS MEMBRANE OF THE STOMACH AND SMALL INTESTINE. By J. ARGYLL CAMPBELL. From the National Institute for Medical Research, Hampstead. (With six figures in the text.) (Received

More information

CRYSTALLIZATION FOULING IN PACKED COLUMNS

CRYSTALLIZATION FOULING IN PACKED COLUMNS CRYSTALLIZATION FOULING IN PACKED COLUMNS D. Großerichter and J. Stichlmair Lehrstuhl für Fluidverfahrenstechnik, Technische Universität München, Munich, Germany ABSTRACT Fouling due to crystallization

More information

International Council of Ophthalmology s Ophthalmology Surgical Competency Assessment Rubric (ICO-OSCAR)

International Council of Ophthalmology s Ophthalmology Surgical Competency Assessment Rubric (ICO-OSCAR) International Council of Ophthalmology s Ophthalmology Surgical Competency Assessment Rubric (ICO-OSCAR) The International Council of Ophthalmology s Ophthalmology Surgical Competency Assessment Rubrics

More information

Satisfaction. For you and your patients.

Satisfaction. For you and your patients. WOMEN S HEALTH SOLUTIONS Satisfaction. For you and your patients. Tissue Removal System & Aquilex Tissue of One solution for hysteroscopic tissue removal. Operative O.D. of 6 mm minimizes the risk of perforation

More information

STUDIES ON CROP FUNCTION IN THE COCKROACH (PERIPLANETA AMERICANA L.)

STUDIES ON CROP FUNCTION IN THE COCKROACH (PERIPLANETA AMERICANA L.) J. Exp. Biol. (1964), 41. 513-524 513 With 10 text-figures Printed in Great Britain STUDIES ON CROP FUNCTION IN THE COCKROACH (PERIPLANETA AMERICANA L.) III. PRESSURE CHANGES DURING FEEDING AND CROP-EMPTYING

More information

TONOMETRY AND PACHYMETRY

TONOMETRY AND PACHYMETRY TONOMETRY AND PACHYMETRY Caroline Pate, OD Associate Professor UAB School of Optometry Birmingham, AL Intraocular Pressure (IOP) The fluid pressure inside the eye The pressure created by the continual

More information

S-CO 2 Brayton Recompression Loop Design and Control

S-CO 2 Brayton Recompression Loop Design and Control S-CO 2 Brayton Recompression Loop Design and Control 1) Background 2) Recommended Design Features 3) Modeling Strategy IST Model Changes Transient Results Prepared by: Mike Hexemer Advanced Concepts Knolls

More information

Chapter 3 EXPERIMENTAL: EQUIPMENT, SET-UP, AND PROCEDURE

Chapter 3 EXPERIMENTAL: EQUIPMENT, SET-UP, AND PROCEDURE Chapter 3 EXPERIMENTAL: EQUIPMENT, SET-UP, AND PROCEDURE 72 3.0 Introduction The experimental work was carried out in three stages. First stage: a laboratory scale single nozzle horizontal jet ejector

More information

THE WAY THE VENTURI AND ORIFICES WORK

THE WAY THE VENTURI AND ORIFICES WORK Manual M000 rev0 03/00 THE WAY THE VENTURI AND ORIFICES WORK CHAPTER All industrial combustion systems are made up of 3 main parts: ) The mixer which mixes fuel gas with combustion air in the correct ratio

More information

Variation of Pressure with Depth in a Fluid *

Variation of Pressure with Depth in a Fluid * OpenStax-CNX module: m42192 1 Variation of Pressure with Depth in a Fluid * OpenStax This work is produced by OpenStax-CNX and licensed under the Creative Commons Attribution License 3.0 Abstract Dene

More information

Naval Postgraduate School, Operational Oceanography and Meteorology. Since inputs from UDAS are continuously used in projects at the Naval

Naval Postgraduate School, Operational Oceanography and Meteorology. Since inputs from UDAS are continuously used in projects at the Naval How Accurate are UDAS True Winds? Charles L Williams, LT USN September 5, 2006 Naval Postgraduate School, Operational Oceanography and Meteorology Abstract Since inputs from UDAS are continuously used

More information

Gas Laws. Introduction

Gas Laws. Introduction Gas Laws Introduction In 1662 Robert Boyle found that, at constant temperature, the pressure of a gas and its volume are inversely proportional such that P x V = constant. This relationship is known as

More information

MyoSure Tissue Removal System. For you and your patients.

MyoSure Tissue Removal System. For you and your patients. Tissue Removal System All-in-one Solution. For you and your patients. One solution for hysteroscopic tissue removal. Now there s a fast, convenient way to remove intrauterine pathology with two powerful

More information

APPENDIX. working blood volume was also rather large; Evans, Grande, and. equilibrated to the new mixture is partially dependent upon the rate

APPENDIX. working blood volume was also rather large; Evans, Grande, and. equilibrated to the new mixture is partially dependent upon the rate 612.172-5 APPENDIX A SIMPLIFIED HEART OXYGENATOR CIRCUIT FOR BLOOD- FED HEARTS. By J. YULE BOG-UE and R. A. GREGORY.' SINCE 1934 studies on the carbohydrate metabolism of the blood-fed heart without lungs

More information

COMMUNICATIONS A RECORDING TONOMETER* designed to be mounted on the patient's forehead and to maintain its position

COMMUNICATIONS A RECORDING TONOMETER* designed to be mounted on the patient's forehead and to maintain its position Brit. J. Ophthal. (1958) 42, 321. COMMUNICATIONS A RECORDING TONOMETER* BY D. M. MAURICE From the Ophthalmological Research Unit, Medical Research Council, Institute of Ophthalmology, University oflondon

More information

PROBLEM SET 9. SOLUTIONS April 23, 2004

PROBLEM SET 9. SOLUTIONS April 23, 2004 Harvard-MIT Division of Health Sciences and Technology HST.542J: Quantitative Physiology: Organ Transport Systems Instructors: Roger Mark and Jose Venegas MASSACHUSETTS INSTITUTE OF TECHNOLOGY Departments

More information

RESTORATION OF HEART RHYTHM DURING FIBRILLATION BY A CONDENSER DISCHARGE

RESTORATION OF HEART RHYTHM DURING FIBRILLATION BY A CONDENSER DISCHARGE RESTORATION OF HEART RHYTHM DURING FIBRILLATION BY A CONDENSER DISCHARGE N. L. G U R V I C H A N D G. S. Y U N 1 E V h e M o s c o w I n s t i t u t e o f P h y s i o l o g y under L. S. Stem has investigated

More information

Valve Losses in Reciprocating Compressors

Valve Losses in Reciprocating Compressors Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 1988 Valve Losses in Reciprocating Compressors Friedrich Bauer Hoerbiger Ventilwerke AG

More information

SOLAR 93 THE 1993 AMERICAN SOLAR ENERGY SOCIETY ANNUAL CONFERENCE. Washington, DC April 22028,1993. Editors: S. M. Burley M. E.

SOLAR 93 THE 1993 AMERICAN SOLAR ENERGY SOCIETY ANNUAL CONFERENCE. Washington, DC April 22028,1993. Editors: S. M. Burley M. E. SOLAR 93 THE 1993 AMERICAN SOLAR ENERGY SOCIETY ANNUAL CONFERENCE Washington, DC April 22028,1993 Editors: S. M. Burley M. E. Arden American Solar Energy Society U.S. Section of the International Solar

More information

technique which have led to increased precision

technique which have led to increased precision THE ACCURACY OF DIRECT DETERMINATIONS OF OXYGEN AND CARBON DIOXIDE TENSIONS IN HUMAN BLOOD IN VITRO 1 By GILES F. FILLEY, ESTHER GAY, AND GEORGE W. WRIGHT (From the Department of Physiology, the Edwtvard

More information

PERFORMANCE MANEUVERS

PERFORMANCE MANEUVERS Ch 09.qxd 5/7/04 8:14 AM Page 9-1 PERFORMANCE MANEUVERS Performance maneuvers are used to develop a high degree of pilot skill. They aid the pilot in analyzing the forces acting on the airplane and in

More information

ZIN Technologies PHi Engineering Support. PHi-RPT CFD Analysis of Large Bubble Mixing. June 26, 2006

ZIN Technologies PHi Engineering Support. PHi-RPT CFD Analysis of Large Bubble Mixing. June 26, 2006 ZIN Technologies PHi Engineering Support PHi-RPT-0002 CFD Analysis of Large Bubble Mixing Proprietary ZIN Technologies, Inc. For nearly five decades, ZIN Technologies has provided integrated products and

More information

Improve pipetting results in pharmaceutical formulation by using MICROMAN E

Improve pipetting results in pharmaceutical formulation by using MICROMAN E Improve pipetting results in pharmaceutical formulation by using MICROMAN E Application Note LT805005 Nadège Belhadj, Gilson, France nbelhadj@gilson.com In pharmaceutical formulation, properties of used

More information

ADAPTATION TO CHANGES OF SALINITY IN THE POLYCHAETES

ADAPTATION TO CHANGES OF SALINITY IN THE POLYCHAETES ADAPTATION TO CHANGES OF SALINITY IN THE POLYCHAETES I. CONTROL OF BODY VOLUME AND OF BODY FLUID CONCENTRATION IN NEREIS DIVERSICOLOR BY L. C. BEADLE University of Durham College of Medicine; Newcastle-on-Tyne

More information

(From the Zoological Laboratory, University of Pennsylvania, Philadelphia.)

(From the Zoological Laboratory, University of Pennsylvania, Philadelphia.) A SIMPLE MICRO VESSEL WITH ELECTRODE FOR DETER- MINING THE HYDROGEN ION CONCENTRATION OF SMALL AMOUNTS OF FLUID. BY JOSEPtt HALL BODINE A~rD DAVID E. FINK. (From the Zoological Laboratory, University of

More information

New Theory on Facial Beauty: Ideal Dimensions in the Face And its application to your practice

New Theory on Facial Beauty: Ideal Dimensions in the Face And its application to your practice New Theory on Facial Beauty: Ideal Dimensions in the Face And its application to your practice By Dr. Philip Young Aesthetic Facial Plastic Surgery 2015 Bellevue, Washington American Brazilian Aesthetic

More information

MODELLING OF FUME EXTRACTORS C. R.

MODELLING OF FUME EXTRACTORS C. R. LD8 19th International Symposium of Ballistics, 7 11 May 21, Interlaken, Switzerland MODELLING OF FUME EXTRACTORS C. R. Woodley WS4 Guns and Warheads Department, Defence Evaluation and Research Agency,

More information

Equation 1: F spring = kx. Where F is the force of the spring, k is the spring constant and x is the displacement of the spring. Equation 2: F = mg

Equation 1: F spring = kx. Where F is the force of the spring, k is the spring constant and x is the displacement of the spring. Equation 2: F = mg 1 Introduction Relationship between Spring Constant and Length of Bungee Cord In this experiment, we aimed to model the behavior of the bungee cord that will be used in the Bungee Challenge. Specifically,

More information

SOLUTIONS Homework #1

SOLUTIONS Homework #1 SOLUTIONS Homework #1 INTRODUCTION TO ENGINEERING IN MEDICINE AND BIOLOGY ECEN 1001- Fall 2003 R. Mihran Due Tuesday, 9/9/03 Question 1: a) Chapter 1 of the text discusses the fact that a significant fraction

More information

ACUTE TEMPERATURE TOLERANCE OF JUVENILE CHINOOK SALMON FROM THE MOKELUMNE RIVER

ACUTE TEMPERATURE TOLERANCE OF JUVENILE CHINOOK SALMON FROM THE MOKELUMNE RIVER ACUTE TEMPERATURE TOLERANCE OF JUVENILE CHINOOK SALMON FROM THE MOKELUMNE RIVER Charles H. Hanson, Ph.D. Hanson Environmental, Inc. SUMMARY A series of static acute tests were performed to determine the

More information

Chapter 3 Atmospheric Thermodynamics

Chapter 3 Atmospheric Thermodynamics Chapter 3 Atmospheric Thermodynamics Spring 2017 Partial Pressure and Dalton Dalton's law of partial pressure: total pressure exerted by a mixture of gases which do not interact chemically is equal to

More information

THE DANGERS OF USING A THREE-WAY VALVE AS A STOPCOCK IN A TRANSDUCER SYSTEM FOR MEASURING VENOUS BLOOD PRESSURE

THE DANGERS OF USING A THREE-WAY VALVE AS A STOPCOCK IN A TRANSDUCER SYSTEM FOR MEASURING VENOUS BLOOD PRESSURE THE DANGERS OF USING A THREE-WAY VALVE AS A STOPCOCK IN A TRANSDUCER SYSTEM FOR MEASURING VENOUS BLOOD PRESSURE J. W. SIVIITH~ PH.D., P.ENr ~ THE SYSTEM shown in Figure 1 has been widely used for the measuring

More information

CHAPTER 3 RESULTS AND DISCUSSION

CHAPTER 3 RESULTS AND DISCUSSION CHAPTER 3 RESULTS AND DISCUSSION The research included the development and verification of the earlier apparatus, and the collection and validation of moisture diffusion data under both isothermal and

More information

INSTRUMENTS A THERMAL MASS FLOW SENSOR USING A CONSTANT DIFFERENTIAL TEMPERATURE ABOVE THE AMBIENT GAS TEMPERATURE

INSTRUMENTS A THERMAL MASS FLOW SENSOR USING A CONSTANT DIFFERENTIAL TEMPERATURE ABOVE THE AMBIENT GAS TEMPERATURE TELEDYNE HASTINGS TECHNICAL PAPERS INSTRUMENTS A THERMAL MASS FLOW SENSOR USING A CONSTANT DIFFERENTIAL TEMPERATURE ABOVE THE AMBIENT GAS TEMPERATURE Proceedings of FEDSM 98 1998 ASME Fluids Engineering

More information

POST MORTEM INTERVAL (TIME OF DEATH) (The Autopsy)

POST MORTEM INTERVAL (TIME OF DEATH)  (The Autopsy) POST MORTEM INTERVAL (TIME OF DEATH) http://library.thinkquest.org/04oct/00206/text_index.htm (The Autopsy) Chemical change in the muscles after death, causing the limbs of the corpse to become stiff and

More information

Circulation and Respiration: Vital Signs Student Version

Circulation and Respiration: Vital Signs Student Version Circulation and Respiration: Vital Signs Student Version In this lab, you will learn about the circulatory and respiratory systems. You will test the capacity of your lungs, measure your blood pressure

More information

DISSOLUTION TEST FOR SOLID DOSAGE FORMS

DISSOLUTION TEST FOR SOLID DOSAGE FORMS Seite 1 von 15 01/2010:20903 corrected 6.8 2.9.3. DISSOLUTION TEST FOR SOLID DOSAGE FORMS This test is provided to determine compliance with the dissolution requirements for solid dosage forms administered

More information

The 7800 Visual Imaging And Patching Chamber, For Upright And Inverted Microscopes.

The 7800 Visual Imaging And Patching Chamber, For Upright And Inverted Microscopes. The 7800 Visual Imaging And Patching Chamber, For Upright And Inverted Microscopes. Abstract The CI7800 was tested to investigate its operational limitations in achieving thermal stability and control

More information

Injector system for implantation of 1stQ foldable intraocular lenses

Injector system for implantation of 1stQ foldable intraocular lenses Instruction For Use 1st Inject Instrument Injector system for implantation of 1stQ foldable intraocular lenses The IFU is available electronically on our website: www.1stq.eu Content: The package contains

More information

Lung Volumes and Capacities

Lung Volumes and Capacities Lung Volumes and Capacities Normally the volume of air entering the lungs during a single inspiration is approximately equal to the volume leaving on the subsequent expiration and is called the tidal volume.

More information

The Variation of Muscle Oxygen Consumption With Velocity of Shortening

The Variation of Muscle Oxygen Consumption With Velocity of Shortening The Variation of Muscle Oxygen Consumption With Velocity of Shortening R.J. BASKIN From the Department of Zoology, University of California, Davis ABSTRACT Total oxygen consumption following contraction

More information

CARBON DIOXIDE ELIMINATION FROM SEMICLOSED SYSTEMS

CARBON DIOXIDE ELIMINATION FROM SEMICLOSED SYSTEMS Brit. J. Anaesth. (1956), 28, 196 CARBON DIOXIDE ELIMINATION FROM SEMICLOSED SYSTEMS BY RUSSELL M. DAVIES, I. R. VERNER Queen Victoria Hospital, East Grinstead AND A. BRACKEN Research and Development Centre,

More information

Micro Channel Recuperator for a Reverse Brayton Cycle Cryocooler

Micro Channel Recuperator for a Reverse Brayton Cycle Cryocooler Micro Channel Recuperator for a Reverse Brayton Cycle Cryocooler C. Becnel, J. Lagrone, and K. Kelly Mezzo Technologies Baton Rouge, LA USA 70806 ABSTRACT The Missile Defense Agency has supported a research

More information

SUMMARY... 2 II. SCOPE... 3 III. LIST OF ABBREVIATIONS AND UNITS... 3 IV.

SUMMARY... 2 II. SCOPE... 3 III. LIST OF ABBREVIATIONS AND UNITS... 3 IV. TEST REPORT 14-0xx In Vitro Accelerated Fatigue Test: x Million Cycle Pulsatile Fatigue and Durability Test of Customer xmm Devices in a Overlapped Configuration Deployed in Curved Vessels Device Manufacturer:

More information

Perfusion Chamber with Porous Membrane for Cellular-Level Glaucoma Research

Perfusion Chamber with Porous Membrane for Cellular-Level Glaucoma Research Preliminary Design Report Perfusion Chamber with Porous Membrane for Cellular-Level Glaucoma Research October 24, 2007 Joey Labuz, BWIG Holly Liske, Leader Laura Piechura, Communicator Kellen Sheedy, BSAC

More information

6I unstable compound with phosphoric acid, which disappears during fatigue. (From the Department of Physiology, The University, Sheffield.

6I unstable compound with phosphoric acid, which disappears during fatigue. (From the Department of Physiology, The University, Sheffield. 6I2.744 ON THE CREATINE AND PHOSPHORUS CONTENT OF MUSCLE. BY MARION BROWN1 AND C. G. IMRIE. (From the Department of Physiology, The University, Sheffield.) IT is well known that the concentration of creatine

More information

An analysis of the air-jet yarn-texturing process part 5: the eect of wetting the yarns

An analysis of the air-jet yarn-texturing process part 5: the eect of wetting the yarns Loughborough University Institutional Repository An analysis of the air-jet yarn-texturing process part 5: the eect of wetting the yarns This item was submitted to Loughborough University's Institutional

More information

PROBLEM SET 7. Assigned: April 1, 2004 Due: April 9, 2004

PROBLEM SET 7. Assigned: April 1, 2004 Due: April 9, 2004 Harvard-MIT Division of Health Sciences and Technology HST.542J: Quantitative Physiology: Organ Transport Systems Instructors: Roger Mark and Jose Venegas MASSACHUSETTS INSTITUTE OF TECHNOLOGY Departments

More information

XI.C. Power-Off Stalls

XI.C. Power-Off Stalls References: FAA-H-8083-3; POH/AFM Objectives Key Elements Elements Schedule Equipment IP s Actions SP s Actions Completion Standards The student should develop knowledge of stalls regarding aerodynamics,

More information

Experimental Analysis on Vortex Tube Refrigerator Using Different Conical Valve Angles

Experimental Analysis on Vortex Tube Refrigerator Using Different Conical Valve Angles International Journal of Engineering Research and Development e-issn: 7-067X, p-issn: 7-00X, www.ijerd.com Volume 3, Issue 4 (August ), PP. 33-39 Experimental Analysis on Vortex Tube Refrigerator Using

More information

PHYS 101 Previous Exam Problems

PHYS 101 Previous Exam Problems PHYS 101 Previous Exam Problems CHAPTER 14 Fluids Fluids at rest pressure vs. depth Pascal s principle Archimedes s principle Buoynat forces Fluids in motion: Continuity & Bernoulli equations 1. How deep

More information

Dissolved Oxygen Guide

Dissolved Oxygen Guide Educat i onser i es Di ssol vedoxygengui de Dissolved Oxygen Guide Introduction Dissolved oxygen probes provide a convenient approach to essentially direct measurement of molecular oxygen. The membrane

More information

CHEMICAL ENGINEERING LABORATORY CHEG 239W. Control of a Steam-Heated Mixing Tank with a Pneumatic Process Controller

CHEMICAL ENGINEERING LABORATORY CHEG 239W. Control of a Steam-Heated Mixing Tank with a Pneumatic Process Controller CHEMICAL ENGINEERING LABORATORY CHEG 239W Control of a Steam-Heated Mixing Tank with a Pneumatic Process Controller Objective The experiment involves tuning a commercial process controller for temperature

More information

UNITED STATES MARINE CORPS WEAPONS TRAINING BATTALION MARINE CORPS COMBAT DEVELOPMENT COMMAND QUANTICO, VIRGINIA

UNITED STATES MARINE CORPS WEAPONS TRAINING BATTALION MARINE CORPS COMBAT DEVELOPMENT COMMAND QUANTICO, VIRGINIA UNITED STATES MARINE CORPS WEAPONS TRAINING BATTALION MARINE CORPS COMBAT DEVELOPMENT COMMAND QUANTICO, VIRGINIA 22134-5040 DETAILED INSTRUCTOR GUIDE LESSON TITLE FUNDAMENTALS OF RIFLE MARKSMANSHIP COURSE

More information

When evolution becomes

When evolution becomes When evolution becomes REvolution Take a glance at the future www.optikon.com Designed to implement innovative technologies and meet every surgical requirement through continuous hardware and software

More information

Leadership in Fluid Management

Leadership in Fluid Management Leadership in Fluid Management Medical Vision leads the development in Fluid Management in arthroscopic surgery, to facilitate better visualization during surgery. Through our unique arthroscopy pump,

More information

When evolution becomes

When evolution becomes When evolution becomes REvolution Take a glance at the future www.optikon.com MINIMAL STRESS: U/S ENERGY Designed to implement innovative technologies and meet every surgical requirement through continuous

More information

Scleral Fitting Guide

Scleral Fitting Guide Scleral Fitting Guide Scleral Lens Design...3 Fitting Philosophy...4 Select a Diagnostic Lens...5 Initial Lens Evaluation...6 Assess Scleral Landing Zone (SLZ), Sagittal Depth, Limbal Clearance, Lens Power...7-10

More information

13.1!"#$#%"&'%()$*+%,+-.$+/*$#

13.1!#$#%&'%()$*+%,+-.$+/*$# 343%%%%%%%%%5)"./$+%67%%%%%!"#$# 13.1!"#$#%"&'%()$*+%,+-.$+/*$#!"#$%&'($)*!"#$%&'($)+ If you want to understand how gases behave such as why fresh air rushes into your lungs when certain chest muscles

More information

MEMORANDUM. Investigation of Variability of Bourdon Gauge Sets in the Chemical Engineering Transport Laboratory

MEMORANDUM. Investigation of Variability of Bourdon Gauge Sets in the Chemical Engineering Transport Laboratory 1 MEMORANDUM TO: FROM: Prof. Davis Hubbard Prof. Faith A. Morrison DATE: 22 April 2014 RE: Investigation of Variability of Bourdon Gauge Sets in the Chemical Engineering Transport Laboratory Introduction

More information

The Aerodynamic Drag of Parafoils

The Aerodynamic Drag of Parafoils The Aerodynamic Drag of Parafoils A. C. Carruthers and A. Filippone The University of Manchester Manchester M60 1QD United Kingdom Introduction The parafoil is an aerodynamic decelerator that uses the

More information

Diaphragm pop-pop engine

Diaphragm pop-pop engine Diaphragm pop-pop engine By Jean-Yves Based on some knowledge got from previous engines we decided to build a new one in order to test various diaphragms. Therefore, where the diaphragm is usually pinched

More information

Effect of Fluid Density and Temperature on Discharge Coefficient of Ogee Spillways Using Physical Models

Effect of Fluid Density and Temperature on Discharge Coefficient of Ogee Spillways Using Physical Models RESEARCH ARTICLE Effect of Fluid Density and Temperature on Discharge Coefficient of Ogee Spillways Using Physical Models M. SREENIVASULU REDDY 1 DR Y. RAMALINGA REDDY 2 Assistant Professor, School of

More information

9 Mixing. I Fundamental relations and definitions. Milan Jahoda revision Radim Petříček, Lukáš Valenz

9 Mixing. I Fundamental relations and definitions. Milan Jahoda revision Radim Petříček, Lukáš Valenz 9 ixing ilan Jahoda revision 14-7-017 Radim Petříček, Lukáš Valenz I Fundamental relations and definitions ixing is a hydrodynamic process, in which different methods are used to bring about motion of

More information

CVEN 311 Fluid Dynamics Fall Semester 2011 Dr. Kelly Brumbelow, Texas A&M University. Final Exam

CVEN 311 Fluid Dynamics Fall Semester 2011 Dr. Kelly Brumbelow, Texas A&M University. Final Exam CVEN 311 Fluid Dynamics Fall Semester 2011 Dr. Kelly Brumbelow, Texas A&M University Final Exam 8 pages, front & back, not including reference sheets; 21 questions An excerpt from the NCEES Fundamentals

More information

Fail Operational Controls for an Independent Metering Valve

Fail Operational Controls for an Independent Metering Valve Group 14 - System Intergration and Safety Paper 14-3 465 Fail Operational Controls for an Independent Metering Valve Michael Rannow Eaton Corporation, 7945 Wallace Rd., Eden Prairie, MN, 55347, email:

More information