Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification ATEX, IECEx, EAC

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification ATEX, IECEx, EAC"

Transcription

1 Table -2/E Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification TEX, IEEx, E valve body spool ex-proof solenoid ex-proof inductive proximity sensor proximity connector (supplied with the valve) DH-0631/2/GK/FI/NO 24D Ex-proof on/off solenoid valves equipped with proximity sensor for the spool position monitoring, multicertified TEX, IEEx, E (see section 7 for solenoid certification). The inductive proximity sensor provides an electric on-off output signal indicating the position of the valve s spool. It has to be electrically fed by means of a safety barrier for intrinsically safe circuits (to be provided on the market), classified for Zone 1 and 2. The solenoid case is designed to contain the possible explosion which could be caused by the presence of the gas mixture inside the housing, thus avoiding dangerous propagation in the external environment. They are also designed to limit the external temperature the certified class to avoid the self ignition of the explosive mixture present in the environment. Note: the valve is not certified for safety applications in conformity to the Machine Directive 2006/42/E pplications: any application in explosive hazardous environments classified Zone 1 or 2 where the valve open/closed condition must be monitored. 1 MODEL ODE OF SPOOL TYPE ON-OFF DIRETIONL SOLENOID VLVES DH /2 - GK / FI * / * 24D ** /* Special execution with ex-proof proximity sensor DH = spool type - direct Valve size (ISO 4401) 0 = 06 Valve configuration, see section 6 Spool type, see section 6 Solenoid threated connection: GK = GK-1/2 ISO/UNI-6125 (tapered) NPT= 1/2 NPT NSI 2.1 (tapered) M = M20x1,5 UNI-4535 (6H/6g) Voltage code 24 VD Series Options: = solenoid at side of port (for single solenoid valves) O = horizontal cable entrance Electrical signal: /NO = electric contact is open when the valve is de-energized /FI = inductive proximity sensor (TEX certified) Seals material - = NR PE = FKM 2 ONFIGURTION ND SPOOLS -71* -630/2-631/2 (1) -61* -67* -630/2/ -631/2/ (1) -61*/ -67*/ (1) onfigurations 63 is available only for spool type 0/2, 1/2 and 2/2 (2) onfigurations 61, 67 and 71 are available only for spools 1, 3 and 4 Where the symbol doesn't show the hydraulic connection (*), it depends on the central configuration of the spool; Spools 0 0/2 1 1/2 2/2 3 4

2 3 MULTIERTIFITIONS In the following are resumed the valves marking multicertifications for Group II 3.1 GROUP II, TEX marking II 2 G = Solenoid for surface plants with gas and vapors environment, category 2, suitable for zone 1 and zone 2 II = Equipment of group II suitable for substances (gas) of group II T6/T4 = Solenoid temperature class (maximum surface temperature) Gb = Equipment protection level, high level protection for explosive Gas atmospheres = Mark of conformity to the applicable European directives II 2 D = Solenoid for surface plants with dust environment, category 2, suitable for zone 21 and zone 22 III = Suitable for conductive dust (applicable also III and/or III) IP66/67 = Protection degree T85/T135 = Maximum surface temperature (Dust) Db = Equipment protection level, high level protection for explosive Dust atmospheres = Mark of conformity to the 94/9/E directive and to the technical norms tex notified TEX Directive IEEx notified IEEx Directive E notified TEX Directive EXMPLE OF NMEPLTE MRKING 3.2 GROUP II, IEEx marking II = Equipment of group II suitable for substances (gas) of group II T6/T4 = Solenoid temperature classes (Gas) Gb = Equipment protection level, high level protection for explosive Gas atmospheres Ex tb = Equipment protection by enclosure tb III = Suitable for conductive dust (applicable also III and/or III) T85 /T135 = Maximum surface temperature (Dust) Db = Equipment protection level, high level protection for explosive Dust atmospheres IP66/67 = Protection degree Note: ccording to EN the valves with tex certification can be coated with a non-metallic material (for ex. paintened), observing the maximum thickness: Group II = 0,2 mm max 3.3 E marking E (Eursian certification) acknowledges the whole TEX Directive 94/9/E. This certification is available only for gas environment (not for dust). II 2 G = Solenoid for surface plants with gas and vapors environment, category 2, suitable for zone 1 and zone 2 II = Equipment of group II suitable for substances (gas) of group II T6/T4 = Solenoid temperature class (maximum surface temperature) = Mark of conformity to the 94/9/E directive and to the technical norms 4 MIN HRTERISTIS ssembly position / location ny position Subplate surface finishing Roughness index Ra 0,4 - flatness ratio 0,01/100 (ISO 1101) MTTFd values according EN ISO mbient temperature range see section 6 for certified temperture class 150 years, for further details see technical table P007 Standard execution = /PE option = Storage temperature range Same as above mbient temperature Operating pressure Ports P,,: 350 bar; Port T 210 bar Rated flow See diagrams Q/Dp at section 10 Maximum flow 70 l/min, see operating limits at section 11 Surface protection Zinc coating with black passivation (body and solenoid housing)

3 5 SELS ND HYDRULI FLUIDS - for other fluids not included in below table, consult our technical office Seals, recommended fluid temperature NR seals (standard) = , with HF hydraulic fluids = FKM seals (/PE option) = Recommended viscosity mm 2 /s - max allowed range mm 2 /s Fluid contamination class ISO 4406 class 21/19/16 NS 1638 class 10, in line filters of 25 mm (b25 _>75 recommended) Hydraulic fluid Suitable seals type lassification Ref. Standard Mineral oils NR, FKM HL, HLP, HLPD, HVLP, HVLPD DIN Flame resistant without water FKM HFDU, HFDR Flame resistant with water NR HF ISO ELETRIL HRTERISTIS Valve type Voltage code (1) VD ±10% Power consumption at 20 oil insulation Protection degree EN60529 Duty factor DH 24D 8W class H IP66/67 100% 7 SOLENOID ERTIFITION DT Valve type ertifications Solenoid certified code Type examination certificate (1) DH Multicertification Group II TEX IEEx E O TEX: ESI 02 TEX 014 IEEx: IEEx ES x E: T RU -IT Method of protection Temperature class Surface temperature mbient temperature TEX 2014/34/EU Ex II 2G Ex d II T6/T4/T3 Gb Ex II 2D Ex tb III T85 /T200 Db T IEEx Ex d II T6/T4/T3 Gb Ex tb III T85 /T200 Db E Ex II 2G Exd II T6/T4 T Mechanical construction Flameproof housing enclosure Ex d EN : 2012, EN : 2007 IE 61508: 2010 able entrance: threaded connection vertical (standard) or horizontal (option /O) GK = GK-1/2 ISO/UNI-6125 (tapered) M = M20x1,5 UNI-4535 (6H/6g) NPT = 1/2 NPT NSI 2.1 (tapered) (1) The type examinator certificates can be downloaded from catalog on line, technical information section WRNING: service work performed on the valve by the end users or not qualified personnel invalidates the certification 8 PROXIMITY SENSOR: MIN DT SENSOR TYPE Y-9-ES S 266-S4 Supply voltage (1) [V] 7,7 9 VD urrent consumption [m] 4 m (de-energized) 1 m (energized) Protection degree IP68 IE Max pressure [bar] 500 mbient temperature Multicertification Ex II 2G Ex ia II T6 Gb (1) For application in explosive environments, the inductive proximity sensor must be electrically supplied by means of a galvanic insulated power amplifier (safety barrier) for intrinsically safe circuits, classified for Zone 1 and 2

4 9 EX PROOF SOLENOIDS WIRING 3 n 4 M4 locking torque 4Nm cover with threaded connection for vertical cable gland fitting cover with threaded connection for horizontal cable gland fitting terminal board for cables wiring standard manual override screw terminal for additional equipotential grounding 1 = oil 2 = GND 3 = oil P 3 poles terminal board suitable for wires cross sections up to 2,5 mm 2 (max WG14) Standard version Option /O LE SPEIFITION ND TEMPERTURE Power supply: section of coil connection wires = 2,5 mm 2 Grounding: section of internal ground wire = 2,5 mm 2 section of external ground wire = 4 mm 2 able temperature The cable must be suitable for the working temperature as specified in the safety instructions delivered with the first supply of the products. Max ambient temperature [ ] Temperature class Max surface temperature [ ] Min cable temperature 45 T6 85 not prescribed 70 T Q/Dp DIGRMS (based on mineral oil ISO VG 46 at 50 ) Spool type Flow direction P P T T PT 0 0/2, 1, 1/ OPERTING LIMITS (based on mineral oil ISO VG 46 at 50 ) The diagram have been obtained with warm solenoids and power supply at lowest value (Vnom-10%). The curves refer to application with symmetrical flow through the valve (i.e. P and T). In case of asymmetric flow the operating limits must be reduced. M valve pressure drop [bar] Inlet pressure [bar] V S Flow rate [l/min] Flow rate [l/min] M = Spools 0, 1; S = Spools 0/2,1/2, 3 V = Spool 4

5 12 INSTLLTION DIMENSIONS ISO 4401: 2005 Mounting surface: Fastening bolts: 4 socket head screws M5x50 class 12.9 Tightening torque = 8 Nm Seals: 4 OR 108 Ports P,,,T: Ø = 7.5 mm (max). P = PRESSURE PORT, = USE PORT T = TNK PORT For the max pressures on ports, see section DH-06* DH-06*/ Option /O DH-07* = screw terminal for additional equipotential grounding = Solenoid wiring 1 = oil 2 = GND 3 = oil = Proximity sensor wiring brown blue cable lenght = 3 mt 09/17

DHAX(S) and DLAHX(S) valves are SIL compliance with IEC (TÜV certified) - see section 1.1 T6, T4 T4, T3 8 W 25 W (2) T4 8 W 25 W 8 W 25 W

DHAX(S) and DLAHX(S) valves are SIL compliance with IEC (TÜV certified) - see section 1.1 T6, T4 T4, T3 8 W 25 W (2) T4 8 W 25 W 8 W 25 W able E135obs/E Stainless steel valves for corrosive environments & water base fluids ex-proof solenoid valves, Multicertification EX, IEEx, E or ULUS certification UL certified valves are obsolete components

More information

Stainless steel valves for corrosive environments & water base fluids

Stainless steel valves for corrosive environments & water base fluids www.atos.com Table E135-10/E Stainless steel valves for corrosive environments & water base fluids explosion-proof soleid valves, with tex, IEEx or UL US certification and pressure relief valves LOHX(S)6-3/M-O/V

More information

Stainless steel valves for corrosive environments & water base fluids

Stainless steel valves for corrosive environments & water base fluids www.atos.com able E135-16/E Stainless steel valves for corrosive environments & water base fluids ex-proof solenoid valves, Multicertification EX, IEEx, E or ULUS certification Ex-proof solenoid Valve

More information

Intrinsically safe solenoid valves on/off controls - ATEX certification

Intrinsically safe solenoid valves on/off controls - ATEX certification www.atos.com Table E130-17/E Intrinsically safe solenoid valves on/off controls - ATEX certification valve body valve spool intrinsically safe solenoid electrical connector manual override DHW-0611/WP/6

More information

Electrically Operated Pressure-Relief Cartridge, Size 10

Electrically Operated Pressure-Relief Cartridge, Size 10 Electrically Operated Pressure-Relief Cartridge, Size 1 Q max = 14 l/min (37 gpm), p max = bar (5 psi) seated pilot stage, spool-type design, with remote contral port Z Series WUVPOC-2, WUVPLC-2 1 Description

More information

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08 Prop. -Way Pressure-Reducing Cart., Size / SAE 8 Q max = 1 l/min (4 gpm), p max = bar (6 psi) Direct acting, electrically operated 1 Description proportional -way pressure-reducing cartridges are size

More information

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cart., Size 2 4 Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 5 bar Direct acting, electrically operated 1 Description inverse proportional pressure-relief valves are direct acting screw-in cartridges

More information

Proportional Throttle Cartridges, Size 16

Proportional Throttle Cartridges, Size 16 Proportional Throttle Cartridges, Size 16 Q max = 5 l/min, p max = 5 bar, Q N max = 14 l/min at p 1 bar Two-Stage, with Seat-Valve Shut-Off 1 Description Normally closed Seat-valve shut-off from 1 Compact

More information

P2* MODULAR SUBPLATES FOR ISO (CETOP 03) VALVES

P2* MODULAR SUBPLATES FOR ISO (CETOP 03) VALVES 52 000/110 ED This series of modular subplates has been designed to make hydraulic circuits and can be used directly on power packs or on any other section of the machine. The subplates are assembled by

More information

Pressure Switches Application Guideline

Pressure Switches Application Guideline Pressure Switches Application Guideline Product Overview The Fema Pressure Switch product portfolio provides devices suitable for many applications. The portfolio contains Special functions and equipment

More information

Check valve hydraulically pilot operated

Check valve hydraulically pilot operated Check valve hydraulically pilot operated RE 6/7.5 Replaces:. / Types SV and SL Nominal sizes to Component series X Maximum operating pressure 5 bar Maximum flow 55 l/min H555 Overview of contents Contents

More information

D62 - D63 Directional Control Valve l/min

D62 - D63 Directional Control Valve l/min D62 - D63 Table of Contents 1 1.1 1.2 Product Description... 2 Function... 2 Properties... 2 2 Technical Data... 3 3 3.1 3.2 Ordering Information... 4 Type code... 4 Versions currently available... 4 4

More information

Pneumatic valve islands

Pneumatic valve islands Pneumatic valve islands The MEGA solenoid air operated spool valve JOUCOMATIC offers a concept of solenoid air operated spool valves which can be fitted together to form islands. Due to its new patented

More information

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.

More information

Pressure reducing valve, pilot operated, Model 3DR

Pressure reducing valve, pilot operated, Model 3DR RA 26 928/06.98 Pressure reducing valve, pilot operated, Model 3DR Nominal size 16 Series 5X Maximum operating pressure 3600 PSI (250 bar) Maximum flow 58.1 GPM (220 L/min) Contents Description Page Features

More information

Pneumatic spool valve islands

Pneumatic spool valve islands Pneumatic spool valve islands P7.GB.R MEGA SPOOL VALVE ISLANDS MEGA pneumatic spool valve islands offer maximum performance along with flexibility, easy installation and simple operation. Due to their

More information

Pressure reducing valve, direct operated

Pressure reducing valve, direct operated Electric Drives and Controls Table of contents Hydraulics Pressure reducing valve, direct operated Model DR 10 DP Nominal size 10 Series 4X Maximum reduced pressure 210 bar (3050 PSI) Maximum flow 80 L/min

More information

RTD temperature probes

RTD temperature probes RTD temperature probes Ex i for use in areas with an explosion hazard (Ex areas) Persons concerned: Experienced professional electricians as per EU Directive 1999/92/EC and trained personnel Operating

More information

Pressure relief valve, direct operated. Type DBD. Features. Contents. RE Edition: Replaces:

Pressure relief valve, direct operated. Type DBD. Features. Contents. RE Edition: Replaces: Pressure relief valve, direct operated Type DBD R 2542 dition: 21-7 Replaces: 214-8 Size 3 Component series 1X Maximum operating pressure 3bar [915 psi] Maximum flow 33 l/min [87 US gpm] H5585 Features

More information

CALEFFI. Ball zone valves. series /03 GB

CALEFFI. Ball zone valves. series /03 GB all zone valves series cert. n ISO / Function Zone valves are used to automatically shut-off the flow of carrier fluid distributed to a system. Specifically: -In central heating systems, they support the

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens A 207 Overview Application The SITRANS P Compact pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials

More information

Pressure relief valve, direct operated Type DBD

Pressure relief valve, direct operated Type DBD Industrial Hydraulics Electric Drives and Controls Linear Motion and Assembly echnologies neumatics Service Automation Mobile Hydraulics RE 25 402/06.02 Replaces: 03.98 Material No.: 00772632a ressure

More information

Mass Flow Controller (MFC)/ Mass Flow Meter (MFM) for gases

Mass Flow Controller (MFC)/ Mass Flow Meter (MFM) for gases Mass Flow Controller (MFC)/ Mass Flow Meter (MFM) for gases Nominal flow ranges from l N /min up to l N /min High accuracy and repeatability Communication via standard signals or Industrial Ethernet Electromagnetic

More information

SPOOL VALVES. ISO 15407/1 - Sizes Series PA568-GB-R3. All leafl ets available at:

SPOOL VALVES. ISO 15407/1 - Sizes Series PA568-GB-R3. All leafl ets available at: SPOOL VLVS ISO 07/ - Sizes 0-0 Series 8-9 P68-GB-R ll leafl ets available at: www.ascojoucomatic.com FTURS These spool valves which comply with the VDM 6 standard offer the advantage of being smaller than

More information

Axial piston pumps type PVC

Axial piston pumps type PVC www.atos.com Table TA16SK-1/E Axial piston pumps type PV variable displacement, by a full line of mechanical controls PV are variable displacement axial piston pumps for medium pressure operation, low

More information

VMR VMR-OTN VMR 6 bar

VMR VMR-OTN VMR 6 bar VMR VMR-OTN VMR 6 bar Safety solenoid valves for gas Fast opening and fast closing type DN8 DN150 delta-elektrogas.com EE161-03/17 VMR VMR-OTN VMR 6 bar Safety solenoid valves for gas Fast opening and

More information

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. Supplied with an electric input signal of 4 to 20

More information

3-Way Safety Block DSV

3-Way Safety Block DSV 3-Way Safety Block DSV DSV 10 - M DSV 10 - M - T-ball DSV 10 - EY 1. Description 1.1. GENERAL The 3-way safety block is used to shut off and discharge hydraulic accumulators or consumers. It complies with

More information

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm Dimensions 65 GW2 40 35 9 5 GW1 14 11 9 5.4 M20 x 1.5 0102 Model Number S M12 x 1.5 Features 77.5 LED V Direct mounting on standard actuators Compact and stable housing with terminal compartment connection

More information

Pressure relief valve, direct operated

Pressure relief valve, direct operated ressure relief valve, direct operated R 25402/05.0 Replaces: 10.05 /1 ype DBD Nominal sizes to 0 Component series 1X Maximum operating pressure 0 bar Maximum flow 0 l/min H5585 Overview of contents Contents

More information

SDM to 8 sections monoblock valve D1WWDA02A

SDM to 8 sections monoblock valve D1WWDA02A SDM 1 SDM1 1 to 8 sections monoblock valve D1WWDA2A SDM1 Additional information This folder shows the product in the most standard configurations. Please contact Sales Dpt. for more detailed information

More information

Fixed Displacement Motor A4FM

Fixed Displacement Motor A4FM Industrial Hydraulics Electric Drives and Controls Linear Motion and ssembly echnologies Pneumatics Service utomation Mobile Hydraulics Fixed Displacement Motor 4FM RE 91 12/4. replaces: 3.95 and RE 91

More information

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications. Rated operating distance s n 5 mm 0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching

More information

Operating Instructions

Operating Instructions Operating Instructions Light-metal Ex d enclosures / flameproof enclosure > 8265/0 Empty enclosure > 8265/4 Control panel, integrated in Ex e enclosure > 8265/5 Control panel Table of Contents 1 Table

More information

SSL. Smart Valve Positioner.

SSL. Smart Valve Positioner. Smart Valve Positioner Smartest valve control device meeting a dynamic performance and a precise setting with a piezoelectric technology and an optimized auto-calibration program Features Auto-Calibration

More information

Operating Instructions

Operating Instructions Operating Instructions Ex d Enclosures in Light Metal / Flameproof Encapsulation > 8265/0 Empty Enclosure > 8265/4 controller, installed in Ex e enclosure > 8265/5 controller Contents 1 Contents 1 Contents...2

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens AG 07 Overview Function U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/ Equipotential bonding Diaphragm The pressure

More information

Hand lever valves VHER

Hand lever valves VHER Hand lever valves VHER Hand lever valves VHER Key features Powerful Flexible Practical -M- Flow 170 3800 l/min 4/3-way valve mid-position closed mid-position exhausted mid-position pressurised Connections:

More information

Directional Controls

Directional Controls Vickers Directional Controls Directional Control Valves DG3V-3-*-60 Hydraulic Operated DG17V-3-*-60 Lever Operated DG18V-3-*-60 Air Operated DG20V-3-*-60 Cam Operated DG21V-3-*-60 Plunger Operated CETOP

More information

EVRM-NC EVRM-6NC. delta-elektrogas.com. Safety solenoid valves for gas Manual reset - Normally closed DN10 DN300.

EVRM-NC EVRM-6NC. delta-elektrogas.com. Safety solenoid valves for gas Manual reset - Normally closed DN10 DN300. EVRM-NC EVRM-6NC Safety solenoid valves for gas Manual reset - Normally closed DN10 DN300 delta-elektrogas.com www.solenoid-valve.world EE166-03/17 EVRM-NC EVRM-6NC Safety solenoid valves for gas Manual

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Bypass MFC with capillary technology for nominal flow rates from 5 ml N /min to 15 l N /min Applicable for aggressive gases Compact design and digital communication

More information

Leak free Pipe Rupture Valve for Excavators

Leak free Pipe Rupture Valve for Excavators Leak free Pipe Rupture Valve for xcavators Series motion and progress Reference: 3 P 9575 1/11.6 Classification: 43.325.355...325.35 1/17 Contents Page 1 General description................................................................

More information

Expert Hydrostatic Level Transmitters

Expert Hydrostatic Level Transmitters Expert Hydrostatic s General Features MJK Expert hydrostatic level transmitters are designed for level measurement by submerging the transmitter in open channels, drains and tanks. Expert hydrostatic level

More information

MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE

MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE SIT Group SIT -3- SIGMA MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE 9.955. Subject to change without notice Application Domestic gas appliances: central heating boilers, combi boilers, instantaneous

More information

DK46 - DK800 Supplementary instructions

DK46 - DK800 Supplementary instructions DK46 - DK800 Supplementary instructions Variable area flowmeter Device category II2G with electrical internals Additional Ex manual KROHNE CONTENTS DK46 - DK800 1 Safety instructions 3 1.1 General... 3

More information

LMU100/200 Series. Standard Specifications

LMU100/200 Series. Standard Specifications Mist Spray Unit MU/ Series Intermittent spray to cutting and press gear chains, etc. Standard Specifications Inlet air Oil tank set range Oil Dynamic viscosity of oil ( C) Oil tank capacity (cm ) mbient

More information

2-way flow control valve Model 2FRM 6

2-way flow control valve Model 2FRM 6 R 28 6/0.98 Replaces R 28 62/05.94 R 28 6/06.98 2-way flow control valve Model 2FRM 6 Nominal size 6 Series X Maximum operating pressure 4569 SI (5 bar) ) Maximum flow 8.45 GM (2 L/min) H//D 585/97 + H//D

More information

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up

More information

Proportional Two-Stage Directional Valves Servo Performance with Double Spool Feedback. KBHDG5V-5/7/8/10 12 Design Pressures to 350 bar (5000 psi)

Proportional Two-Stage Directional Valves Servo Performance with Double Spool Feedback. KBHDG5V-5/7/8/10 12 Design Pressures to 350 bar (5000 psi) Proportional Two-Stage Directional Valves Servo Performance with Double Spool Feedback KHDG5V-5/7/8/1 12 Design Pressures to 35 bar (5 psi) Contents INTRODUCTION General description....3 Features and benefits....3

More information

Solenoid Valves VUVG Overview

Solenoid Valves VUVG Overview Solenoid Valves VUVG Overview Universal valve Combination of basic valve and E-boxes Width 10 mm and 14 mm In-line valves VUVG-L and VUVG-S Sub-base valves VUVG-B Internal or external pilot air supply

More information

Mechanical pressure switches

Mechanical pressure switches 18 Technical features / Advantages Diecast aluminium housing IP 54 or IP 65 version also available Wall mounting or directly on the pressure line Switching element (microswitch) Lead sealable setpoint

More information

Electronic Turbine Meter TERZ 94

Electronic Turbine Meter TERZ 94 Electronic Turbine Meter TERZ 9 PRODUT INFORMTION Reliable Measurements of Gas EETRONI TURINE METER TERZ 9 Methode of operation, construction 2 Methode of operation The TERZ 9 electronic turbine meter

More information

GS-20/25 and GS-40/45 Series Single-block Multi-function Gas Control Valves

GS-20/25 and GS-40/45 Series Single-block Multi-function Gas Control Valves Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin GS-20/25 GS-40/45 Issue Date 1298 GS-20/25 and GS-40/45 Series Single-block Multi-function Gas

More information

Monoblock Directional Control Valve RMB 202

Monoblock Directional Control Valve RMB 202 Monoblock Directional Control Valve RMB 202 Key valve features RMB 202 is a 2-section mono block valve, especially designed for front-end loaders. The valve is prepared for quick connecting couplings,

More information

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9 Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Fluid Proof pressure Operating pressure differential range (Difference between tank pressure and line pressure) Vibration resistance

More information

Process Solutions. Electronic Turbine Meter TERZ 94 PROVEN TECHNOLOGY. SUPERIOR PERFORMANCE.

Process Solutions. Electronic Turbine Meter TERZ 94 PROVEN TECHNOLOGY. SUPERIOR PERFORMANCE. Process Solutions Electronic Turbine Meter TERZ 9 PROVEN TEHNOOGY. SUPERIOR PERFORMNE. Electronic Turbine Meter TERZ 9 Method of Operation The TERZ 9 electronic turbine meter is a flow meter which directly

More information

Pressure relief valves

Pressure relief valves Pressure relief valves Type DV700 Features Direct operated valve High degree of pressure stability Safe operation Precise pressure adjustment Maximum pressure setting with lock nut Applications as cartridge

More information

2/2-way proportional valve

2/2-way proportional valve 2/2-way proportional valve General purpose 0... 12 bar DN 0.8... 2.0 mm 1/8 or sub-base version Type 2824 can be combined with Type 805 Digital control electronics DIN-rail version Type 07 Cable plug Typ

More information

Technical Data. Dimensions

Technical Data. Dimensions 00 Model Number Features mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,

More information

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves single-stage atmospheric operating mode GB-(LEP) 057 D01

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves single-stage atmospheric operating mode GB-(LEP) 057 D01 Gasloc Multifunctional gas control Combined regulator and safety shut-off valves single-stage atmospheric operating mode G-(LEP) 057 D01 3.10 Printed in Germany Edition 05.11 Nr. 249 584 1 6 Technical

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx CML 14.0034X Issue No:

More information

INSTRUCTION MANUAL Pressure Relief Device LPT

INSTRUCTION MANUAL Pressure Relief Device LPT INSTRUCTION MANUAL Pressure Relief Device LPT 5COV475800 LPT REV00 CONTENT: 1 SAFETY 1.1 Safety instructions 2 1.2 Specified applications 2 1.3 Safety notes on the equipment operation 2 2 PRESSURE RELIEF

More information

Fixed Displacement Pump KFA for commercial vehicles in open circuits

Fixed Displacement Pump KFA for commercial vehicles in open circuits RE 91 501/05.98 Replaces: 11.96 Fixed Displacement Pump KFA for commercial vehicles in open circuits Sizes 23...107 Series 6 Nominal pressure 300 bar Peak pressure 350 bar KFA List of contents Features

More information

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-00-VEF 7.03 Max. operating pressure 30 mbar Compact design High flow values Low weight Low power consumption

More information

Digital relief valves D-CG

Digital relief valves D-CG Digital relief valves D-G unctional Symbols D-G- Specifications Size Maximum working pressure Rated flow Maximum flow Maximum adjustable pressure Ma Minimum control pressure Hysteresis Repeatability emperature

More information

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm Dimensions 65 9 5 40 35 14 11 9 5.4 M20 x 1.5 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting Satisfies machinery

More information

Prewired position switches FA series

Prewired position switches FA series 2 Prewired position switches FA series Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 51 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable lever 41 45

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 00 Model Number Features 5 mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,

More information

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10 / ED VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES OPERATING PRINCIPLE The VPPL are variable displacement axial-piston pumps with variable swash plate, suitable for applications

More information

MJK Expert 700 / 800 / 900 / 7070 / 7060 MJK Expert 1400 / 3400

MJK Expert 700 / 800 / 900 / 7070 / 7060 MJK Expert 1400 / 3400 MJK Expert 700 / 800 / 900 / 7070 / 7060 MJK Expert 1400 / 3400 Submersible Hydrostatic s Rugged and versatile 2.75 GB 2.75 Expert 090311 We reserve the right to continuously improve our products and make

More information

E28/Q28 Safety Exhaust Valve Externally Monitored

E28/Q28 Safety Exhaust Valve Externally Monitored E8/Q8 Safety Exhaust Valve Externally Monitored ulletin 9EM4 the total systems approach to air preparation Features Externally Monitored Safety Exhaust Valve Function When applications demand a safe environment

More information

GA24 Technical Datasheet

GA24 Technical Datasheet GA24 Technical Datasheet Variable-area flowmeter Sturdy construction for several applications Local indication without auxiliary power Replaceable mounting parts KROHNE CONTENTS GA24 1 Product features

More information

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC Mechatronic pressure measurement Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC WIKA data sheet PV 35.41 Process Compact Series Applications Differential pressure monitoring

More information

UL Listed GM-20/25 and GM-40/45 Series Dual-block Multi-function Gas Control Valves

UL Listed GM-20/25 and GM-40/45 Series Dual-block Multi-function Gas Control Valves Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin GM-20/25 GM-40/45 Issue Date 1298 UL Listed GM-20/25 and GM-40/45 Series Dual-block Multi-function

More information

Proportional pressure regulators VPPE

Proportional pressure regulators VPPE Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/

More information

Position switches FP series

Position switches FP series A Position switches FP series Selection diagram 0 08 8 9 0 0 0 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fiber glass rod gasket sphere sphere adjustable lever safety adjustable lever

More information

Directional Controls

Directional Controls Vickers Directional Controls Lever Operator Directional Control Valves DG17S-8-**-10 DG17S4-10 **-50 NF D08/D10, ISO-4401-08/10 Released 5/94 681 able of Contents General Information..................................................................................

More information

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073 Operating instructions Safety Rope Emergency Stop Switches UK ZB0052 / ZB0053 ZB0072 / ZB0073 7390878 / 02 03 / 2011 Contents 1 Safety instructions...3 2 Installation / set-up...4 2.1 Applications...4

More information

Pressure control, differental pressure control and thermostat Type RT

Pressure control, differental pressure control and thermostat Type RT MAKING MODERN LIVING POSSIBLE Technical brochure Pressure control, differental pressure control and thermostat Type RT Hydrocarbons www.danfoss.com/hydrocarbons Contents Page Introduction...3 Approvals...3

More information

Change-Over Pressure Filter DFDK

Change-Over Pressure Filter DFDK Change-Over Pressure Filter up to 8 l/min, up to 35 bar 3 6 4 6 4 8 33 5 66.x 66.x 99.x 3.x 3 3.x 64 3.x 396 3.x. TECHNICAL SPECIFICATIONS. FILTER HOUSING Construction The filter housings are designed

More information

Diaphragm Accumulators

Diaphragm Accumulators 1. DESCRIPTION 1.1. FUNCTION Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas is utilised in hydro-pneumatic accumulators for storing fluids.

More information

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly. Components preparation and pressure adjustment ABP Overview ABP is a component that enables boosting by s only up to twice primary pressure (.0MPa max.) in combination with using air tank but not using

More information

Manual Power relay SR853

Manual Power relay SR853 Manual Power relay SR853 Rev. 0 SR853 manual page2 Safety Guidelines for explosion proof devices Application and Standards This instruction manual applies to explosion protected control systems of protection

More information

Pressure switch, Differential pressure switch and Thermostat RT-E

Pressure switch, Differential pressure switch and Thermostat RT-E Data sheet Pressure switch, Differential pressure switch and Thermostat RT-E The RT-E series consist of pressure and differential pressure switches as well as thermostats. The units are designed for industrial

More information

Tightness controls TC 1 3 and TC 4

Tightness controls TC 1 3 and TC 4 Tightness controls TC 1 3 and TC 4 Test of both safety valves Short test period thanks to logical decision-making in the program sequence Adjustable test period which can be adapted to different systems

More information

SITRANS. Pressure transmitter SITRANS P, Z series for gauge and absolute pressure. Introduction. Safety instructions 2.

SITRANS. Pressure transmitter SITRANS P, Z series for gauge and absolute pressure. Introduction. Safety instructions 2. Introduction 1 Safety instructions 2 SITRANS Pressure transmitter SITRANS P, Z series for gauge and absolute pressure 7MF1564 Description 3 Assembly and connection 4 Technical data 5 Dimensional drawings

More information

AMT-Ex Dewpoint Transmitter

AMT-Ex Dewpoint Transmitter AMT-Ex Dewpoint Transmitter Instruction Manual Alpha Moisture Systems Alpha House 96 City Road Bradford BD8 8ES England Tel: +44 1274 733100 Fax: +44 1274 733200 email: mail@amsytems.co.uk web: www.amsystems.co.uk

More information

Pressure & Temperature Switches

Pressure & Temperature Switches Pressure & Temperature Switches The User Friendly Generation General Bulletin TEMPERATURE SWITCHES BETA TEMPERATURE SWITCH The BETA Temperature Switch is a pressure switch incorporating a sealed 2-phase

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 2 mm flush Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 2 mm Installation flush Output

More information

Compact Regulator. ARX20 Series. 2.0 MPa compatible, piston type compact regulator ARJ

Compact Regulator. ARX20 Series. 2.0 MPa compatible, piston type compact regulator ARJ Compact Regulator 2 Series 2. MPa compatible, piston type compact regulator V SR X AP1 Compatible with inlet supply pressure of 2. MPa Employs a knob shape for easy operation Compact type (face to face

More information

MULTIPOL - VDMA. PNEUMATIC SPOOL VALVE ISLANDS VDMA ISO 02 - ISO 01 (G1/8 - G1/4) designed for connection to a PLC by multiwire cable

MULTIPOL - VDMA. PNEUMATIC SPOOL VALVE ISLANDS VDMA ISO 02 - ISO 01 (G1/8 - G1/4) designed for connection to a PLC by multiwire cable P8.G.R PEUATIC SPOOL VALVE ISLADS VDA - ISO - ISO (G/8 - G/) designed for connection to a PLC by multiwire cable ULTIPOL - VDA IPUT IPUT OUTPUT OUTPUT OUTPUT IPUT IPUT ULTIPOL - VDA Pneumatic spool valve

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation 2/2- and 3/2-way cartridge solenoid valve 2/2- und 3/2-Wege-Cartridge-Magnetventil Électrovanne cartridge à 2/2 ou 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation We reserve the

More information

ELECTRIC ACTUATORS for continuous underwater use

ELECTRIC ACTUATORS for continuous underwater use ELECTRIC ACTUATORS for continuous underwater use The SA multi-turn actuator for continuous underwater use by AUMA opens new applications for electric actuators for water supply, in hydropower plants and

More information

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25 Self-operated Pressure Regulators Differential Pressure Regulators (opening) Type 42-20 Type 42-25 Type 42-20 Differential Pressure Regulator Type 42-25 Differential Pressure Regulator Mounting and Operating

More information

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH THIS MANUAL IS INTENDED FOR TECHNICAL STAFF IN CHARGE OF THE INSTALLATION, THE OPERATION AND THE MAINTENANCE OF THIS PRODUCT CAUTION!

More information

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB Air Sensor SAC Ex Manual AQ Elteknik AB ATEX Air Sensor SAC Ex ATEX Certified model Manual version 2.1 April 2014 AQ Elteknik AB 2 Table of contents 1. Manufacturer information... 4 Manufacture Declaration

More information

Compressed Air Cleaning Filter Series

Compressed Air Cleaning Filter Series Compressed ir Cleaning Filter Series M /FF Series For Water Droplet, Solid/Oil Separation and Deodorization Modular connection, Space-saving design, Labor-saving in piping! Uses the same spacer as the

More information

Two-stage valve type NE

Two-stage valve type NE Two-stage valve type NE Product documentation Operating pressure pmax: Flow rate Qmax: 700 bar (High pressure) 80 bar (Low pressure) 25 lpm (High pressure) 180 lpm (Low pressure) D 7161 03-2017-1.0 by

More information

SPECIFICATIONS ATTENTION

SPECIFICATIONS ATTENTION VPS 504 S06 Installation Manual - P/N 80122 - Ed. 01/09 VPS 504 S06 and S05 Valve Proving System Installation Instructions VPS 1 6 Gases Natural gas, air and other inert gases. NOT suitable for butane

More information

CENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES

CENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES P0170E-1.DOCX/08.16/MG CENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES With a Central Gas Supply System, individual work places or gas take-off stations are supplied with gas through

More information