Multistage Ejector Series ZL

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "Multistage Ejector Series ZL"

Transcription

1 Multistage Ejector Series. Energy-saving, large flow rate, 3 stage diffuser construction Suction flow rate increased 5% and air consumption reduced % with 3 stage diffuser construction (ersus ø.3, one stage model) acuum pressure sensor With adaptor for vacuum acuum pressure stage performance Series Q Q Q3 Q Q Q3 stage performance 5% suction flow rate increase 3 stage performance Suction flow rate Diffusers stacked and integrated Compact size and large flow rate (Twice the flow rate of the ) With vacuum pressure gauge Digital vacuum pressure switch Rated pressure range:. to. ka 3-step setting 3 S ZSE3A Release valve Supply valve Release flow rate adjusting needle Suction flow rate (l/min (ANR)) With One-touch fittings Makes piping work easy ( only) Air consumption (l/min (ANR)) 63 6 Built-in silencer ort exhaust A Z S AM AE HE ush Adjust to set-value with buttons. ush Finish setting ower-saving function ower consumption is reduced by turning off the monitor. (Reduce power consumption by up to %.) For series ZSE3A, refer to the separate catalog (CAT.ES-7) for details. Series ariations Series Maximum suction flow rate (l/min (ANR)) Air consumption (l/min (ANR)) Built-in silencer ort exhaust With digital vacuum pressure switch With supply and release valves With supply valve ZSE3A acuum pressure sensor option acuum pressure gauge acuum adapter

2 Multistage Ejector Series How to Order Without valve K 5 M Z Nozzle diameter. mm Exhaust type Built-in silencer ort exhaust (EXH) thread type (ort exhaust only) Note 3) The thread ridge shape is conforming to G thread standard (JIS B3), but other shapes are not conforming to ISO63 and ISO79. F N T Rc/ G/ (3) /-4 NT /-4 NTF Supply valve/release valve combination K K With supply and release valves With supply valve Lead wire specifications (Applicable only when the vacuum pressure sensor specification is D for digital pressure switch for vacuum) L Lead wire with connector (Length m) Unit specifications (Applicable only when the vacuum pressure sensor specification is D for digital pressure switch for vacuum) M With unit switching function SI unit only With unit switching function (Initial value psi) Note ) W/ unit switching function is not permitted to sell for the domestic use in Japan, because the new Weight and Measure Act has been implemented since October, 99. Note ) Fixed unit: ka Rated voltage DC specifications S 5 R 3 AC specifications (5/6 Hz) 3 4 [5] [3] G H L LN LO M MN MO Grommet L plug connector M plug connector Electrical entry S Z U Lead wire length.3 m Lead wire length.6 m Lead wire length.3 m Without lead wires Without connector Lead wire length.3 m Without lead wires Without connector Light/Surge voltage suppressor Without light/surge voltage suppressor With surge voltage suppressor With light/surge voltage suppressor With light/surge voltage suppressor (Non-polar type) Type U is 4 or DC only. Since surge voltage is prevented by a rectifier in the case of AC, there is no type S. D Non-locking push type Locking slotted type Manual override Output specifications (Applicable only when the vacuum pressure sensor specification is D for digital pressure switch for vacuum) N A B C D E F acuum pressure sensor GN G D NN open collector output N open collector output NN open collector outputs N open collector outputs NN open collector output + Analog voltage output NN open collector output + Analog current output N open collector output + Analog voltage output N open collector output + Analog current output None acuum port adaptor Rc /8 acuum pressure gauge Digital pressure switch for vacuum 68

3 Multistage Ejector Series Standard With vacuum pressure gauge Adapter ort exhaust Ejector Specifications Model Nozzle diameter Maximum suction flow rate Air consumption Maximum vacuum pressure Maximum operating pressure Supply pressure range Standard supply pressure Operating temperature range Supply/Release alve Specifications art no. Type of valve actuation Fluid Operating pressure range Internal pilot type Ambient and fluid temperature Response time (For.5 Ma) () Maximum operating frequency Manual override ilot exhaust type Lubrication Mounting position Impact/ibration resistance () Enclosure Option Specifications. mm l/min (ANR) 63 l/min (ANR) 84 ka.7 Ma. to.5 Ma.4 Ma 5 to 5 C SYJ54- -S N.C. Air. to.5 Ma 5 to 5 C 5 ms or less 5 Hz Non-locking push type/locking slotted type ilot valve individual exhaust, Main valve/ilot valve common exhaust Not required Unrestricted 5/3 m/s Dust proof Note ) Based on JIS B dynamic performance test. (coil temperature C, at rated voltage, without surge voltage suppressor) Note ) Impact resistance: No malfunction when tested with a drop tester in the axial direction and at a right angle to the main valve and armature, one time each in both energized and deenergized states. (initial value) ibration resistance: No malfunction when tested with one sweep of 45 to Hz in the axial direction and at a right angle to the main valve and armature, one time each in both energized and deenergized states. (initial value) Note 3) Refer to Best neumatics No. for details on valves. acuum ressure Gauge Specifications art no. GZ3S Fluid Air ressure range to ka Scale range (Angular) 3 Accuracy ±3% F.S. (Full span) Class Class 3 Operating temperature range to 5 C Material Housing: olycarbonate/abs resin A Z S AM AE HE JIS Symbol Standard Mass (Basic) ort exhaust Digital pressure switch for vacuum (Excluding lead wire) Digital pressure switch for vacuum (Including 3 cores lead wire) Digital pressure switch for vacuum (Including 4 cores lead wire) alve (per pc.) 45 g + g +43 g +8 g +85 g +45 g 69

4 Series acuum ressure Switch Unit/Digital ressure Switch for acuum: ZSE3A-- - -X55 How to Order ZSE3A X55 Symbol N A B C D E F Output specifications Output Analog output Type oint oltage Current NN N NN N NN NN N N Option (Operating manual specifications) Y Operating manual (Leaflet) Without operating manual Option (Connector/Lead wire specifications) L Without lead wire Lead wire with connector (Length m) Display unit With unit display switching function M Fixed SI unit With unit display switching function (Initial value psi) Specifications Rated pressure range Set pressure range Withstand pressure Minimum unit setting Applicable fluid ower supply voltage Current consumption Switch output Maximum load current Maximum applied voltage Residual voltage Response time Short circuit protection Repeatability Hysteresis mode Window comparator mode Hysteresis Analog output Output voltage (Rated pressure range) Linearity Output impedance Output current (Rated pressure range) Linearity Load impedance. to. ka. to 5. ka 5 ka. ka Air, Non-corrosive gas, Non-flammable gas to 4 DC ±% (with power supply polarity protection) 4 ma (at no load) NN or N open collector output NN or N open collector outputs (selectable) 8 ma 8 (at NN output) or less (with load current of 8 ma).5 ms or less (with anti-chattering function:,, 5,, ms) Yes ±.% F.S. ± digit ariable ( to variable) to 5 ±.5% F.S. ±% F.S. or less Approx. kω 4 to ma ±.5% F.S. ±% F.S. or less Maximum load impedance: ower supply voltage : 3 Ω, ower supply voltage 4 : 6 Ω Minimum load impedance: 5 Ω Display 4-digit, 7-segment, -color LCD (Red/Green) Sampling cycle: 5 times/sec. Display accuracy ±% F.S. ± digit (Ambient temperature of 5 C) Indicator light Lights up when switch output is turned ON. (OUT: Green, OUT: Red) Enclosure I4 Operating temperature range Operating: to 5 C, Stored: to 6 C (No freezing or condensation) Operating humidity range Operating/Stored: 35 to 85% RH (No condensation) Withstand voltage AC for minute between live parts and case Insulation resistance 5 MΩ or more between live parts and case (at 5 DC Mega) to 5 Hz at whichever is smaller of.5 mm amplitude or ibration resistance m/s acceleration, in X, Y, Z directions, for hours each Impact resistance m/s, in X, Y, Z directions, for hours each Temperature characteristics ±% F.S. (Based on 5 C) Oilproof heavy-duty vinyl cable, 3 cores ø3.5, m Lead wire 4 cores Conductor area:.5 mm (AWG6) Insulator O.D.:. mm Standards CE Marking, UL/CSA, RoHS compliance Note ) When analog voltage output is selected, analog current output cannot be used together. Note ) When analog current output is selected, analog voltage output cannot be used together. Environment resistance Note ) oltage output Note ) Current output 7

5 Multistage Ejector Series Exhaust Characteristics/Flow Characteristics/Time to Reach acuum Exhaust Characteristics acuum pressure (ka) Flow Characteristics acuum pressure (ka) Time to Reach acuum acuum pressure in tank (ka) Supply pressure (Ma) Exhaust Characteristics acuum pressure acuum pressure Suction flow rate Air consumption Suction flow rate (l/min (ANR)) Air consumption (l/min (ANR)) Supply pressure:.4 Ma Suction flow rate (l/min(anr)) 3 Tank capacity: l Supply pressure:.4 Ma acuum pressure reached 89ka 8ka 66ka 53ka 4ka 6ka 3ka Time to reach vacuum (S) <How to Read the Graph> The graphics indicate the time required to reach a vacuum pressure determined by adsorption conditions for workpieces, etc., starting from atmospheric pressure in a l sealed tank. Approximately 8.8 seconds are necessary to attain a vacuum pressure of 89 ka. acuum pressure (ka) Flow Characteristics acuum pressure (ka) Time to Reach acuum acuum pressure in tank (ka) acuum pressure Supply pressure (Ma) Supply pressure:.4 Ma Suction flow rate (l/min(anr)) Q Qmax Suction flow rate Suction flow rate Air consumption Tank capacity: l Supply pressure:.4 Ma acuum pressure reached 89ka 8ka Time to reach vacuum (S) Suction flow rate (l/min (ANR)) Air consumption (l/min (ANR)) 66ka 53ka 4ka 6ka 3ka <How to Read the Graph> The flow characteristics indicate the relationship between the vacuum pressure and the suction flow rate of the ejector, and show that when the suction flow rate changes the vacuum pressure also changes. In general, this indicates the relationship at the ejector s standard operating pressure. In the graph, max indicates the maximum vacuum pressure, and Qmax indicates the maximum suction flow rate. These are the values that are published as specifications in catalogs, etc. Changes in vacuum pressure are explained below. max. If the ejector s suction port is closed and sealed tight, the suction flow rate becomes and the vacuum pressure increases to the maximum (max).. If the suction port is opened and air is allowed to flow (the air leaks), the suction flow rate increases and the vacuum pressure decreases. (the condition of and Q) 3. If the suction port is opened completely, the suction flow rate increases to the maximum (Qmax), while the vacuum pressure then drops almost to (atmospheric pressure). When adsorbing work pieces which are permeable or subject to leakage, etc., caution is required as the vacuum pressure will not be very high. A Z S AM AE HE 7

6 Series Construction Without valve Comonent arts Replacement arts No Description art no. Note No. Description Material art no. Suction cover 9 Sound absorbing material B F -S Front cover Without valve Sound absorbing material A F (Set no. for 9, & ) End cover Suction filter E Body acuum sensor unit Nozzle Diffuser Detent plug Other than vacuum switch Lead wire cover acuum switch specifications Front cover B alve plate Needle Supply valve (N.C.) SYJ54- -S Release valve (N.C.) SYJ54- -S 7

7 Multistage Ejector Series Dimensions: Series (Without valve) 5 7 x ø5.4 Label Standard Rc / 35 ort exhaust (/-4 NTF, G / /-4 NT) acuum pressure gauge x ø5.4 4 A With vacuum pressure gauge -G acuum adapter Rc /8 x ø5.4 7 With vacuum adapter -GN Z 6 S Digital pressure switch for vacuum x ø5.4 With digital pressure switch for vacuum S AM -D (9) AE HE Air pressure supply port () Applicable tubing O.D. 6 acuum port () Applicable tubing O.D. Section A x ø MULTISTAGE EJECTOR 59.5 Label Section A/ With Digital ressure Switch for acuum -D (ZSE3A) x M4 Thread depth 8 () (5.8)

8 + + + Series Dimensions: Series (With alve) With supply valve and release valve -K L -D Digital pressure switch for vacuum x ø5.4 Manual override 3.5 Release valve S Supply valve Manual override Release flow rate adjusting needle Air pressure supply () port Applicable tubing O.D. 6 acuum () port Applicable tubing O.D. x ø5.4 (9) (6.8) Label 8 9 Circuit diagram (3) (5.8) x M4 x.7 Thread depth 8 () With supply valve -K L -D Blanking plate assembly (SYJ5--3A) Digital pressure switch for vacuum S Supply valve Circuit diagram 74

9 Multistage Ejector Series Standard With vacuum pressure gauge With digital vacuum pressure switch With adaptor ort exhaust GN G D Nozzle diameter. mm Exhaust specifications Built-in silencer ort exhaust acuum pressure sensor Model Nozzle diameter Maximum suction flow rate Air consumption Maximum vacuum pressure Maximum operating pressure Supply pressure range Standard supply pressure Operating temperature range None acuum port adaptor Rc /8 acuum pressure gauge Digital pressure switch for vacuum Ejector Specifications How to Order Lead wire specifications (Applicable only when the vacuum pressure sensor specification is D for digital pressure switch for vacuum) L Lead wire with connector (Length m) Unit specifications (Applicable only when the vacuum pressure sensor specification is D for digital pressure switch for vacuum) M Note ) W/ unit switching function is not permitted to sell for the domestic use in Japan, because the new Weight and Measure Act has been implemented since October, 99. Note ) Fixed unit: ka N A B C D E F ø. mm x l/min (ANR) 6 l/min (ANR) 84 ka.7 Ma. to.5 Ma.4 Ma 5 to 5 C With unit switching function SI unit only With unit switching function (Initial value psi) Output specifications (Applicable only when the vacuum pressure sensor specification is D for digital pressure switch for vacuum) NN open collector output N open collector output NN open collector outputs N open collector outputs NN open collector output + Analog voltage output NN open collector output + Analog current output N open collector output + Analog voltage output N open collector output + Analog current output A Z S AM AE HE Made to Order (Refer to page 78 for details.) JIS Symbol Standard Mass ort exhaust Digital pressure switch for vacuum (Excluding lead wire) Digital pressure switch for vacuum (Including 3 cores lead wire) Digital pressure switch for vacuum (Including 4 cores lead wire) alve (per pc.) 7 g +3 g +43 g +8 g +85 g +45 g 75

10 Series Construction Component arts Replacement arts No. Description Note No. Description Material art no. Suction cover Front cover A 9 Sound absorbing material A Sound absorbing material F F -S (Set no. for 9 & ) 3 End plate 4 Body 5 acuum sensor unit 6 Nozzle 7 Diffuser 8 Detent plug Lead wire cover Other than vacuum switch acuum switch specifications 76

11 S Multistage Ejector Series Dimensions: Series Air pressure supply port () Rc /8 acuum port() Rc 3/4 76 Standard Label 6 ort exhaust A acuum pressure gauge (EXH.) Rc 5 With vacuum pressure gauge -G acuum adapter Rc /8 7 With vacuum adapter -GN Z S Digital pressure switch for vacuum With digital pressure switch for vacuum -D MULTISTAGE EJECTOR Section A (9) x ø4.4 AM AE HE (4) x M5 x.8 Thread depth 6 () Section A/ With Digital ressure Switch for acuum -D 3 (5.8) 77

12 + + S Series Made to Order Specifications lease contact SMC for detailed specifications, dimensions and delivery. With Supply and Release alves alve oltage Electrical entry acuum pressure switch Electrical entry X3 With supply and release valves type with supply and release valves Dimensions SMC

13 Series Specific roduct recautions Be sure to read before handling. Refer to front matters 38 and 39 for Safety Instructions and pages 844 to 846 for acuum recautions. Operation of Ejector alves Caution. When the air supply valve is turned ON, vacuum is generated by the flow of compressed air from the nozzle to the diffuser. When the vacuum release valve is turned ON, the vacuum is quickly released as air passes through the release flow adjustment needle and flows to the vacuum port. Caution Caution Operating Environment. Avoid use exposed to direct sunlight. Solenoid alves (Series ). For specific product precuations on solenoid valves, refer to the solenoid valve (Series SYJ5) catalog. A Z S AM AE HE 79

CAT.E813- B. Multistage Ejector. Series ZL. New Models! ZL212 large flow rate type and ZL112 with valve.

CAT.E813- B. Multistage Ejector. Series ZL. New Models! ZL212 large flow rate type and ZL112 with valve. CAT.E813- B Multistage Ejector Series ZL New Models! ZL212 large flow rate type and ZL112 with valve. Multistage Ejector Series ZL112/212 Energy saving, large flow rate, 3 stage diffuser construction Suction

More information

Precision Regulator. Series Model Regulating pressure range Port size Page

Precision Regulator. Series Model Regulating pressure range Port size Page Precision Regulator Series // Basic Type Air Operated Type Series Model Regulating pressure range Page Series Series Series Series Series.5 to MPa. to MPa. to.8 MPa /8 55.5 to MPa. to MPa /4 55. to.8 MPa.

More information

1.0. ISE70/71 Series CAT.ES A. MPa/1.6 MPa. 3-Screen Display High-Precision Digital Pressure Switch. Angled display.

1.0. ISE70/71 Series CAT.ES A. MPa/1.6 MPa. 3-Screen Display High-Precision Digital Pressure Switch. Angled display. 3-Screen Display High-Precision Digital Pressure Switch For Air 1.0 ISE70 ISE71 MPa/1.6 MPa RoHS IP67 It is possible to change the settings while checking the measured value. Main screen Measured value

More information

KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media

KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media FEATURES 50 mbar to 400 bar, 5 to 6000 psi gage or absolute pressure For many industrial gases and liquids 00, 0545, 05, 6 or 40 ma output Field interchangeable EMC according to EN 66-8 MEDIA COMPATIBILITY

More information

Compact Manometer. Pressure measurements can easily be taken any time, anywhere. POWER LIGHT

Compact Manometer. Pressure measurements can easily be taken any time, anywhere. POWER LIGHT Compact Manometer Series PPA Pressure measurements can easily be taken any time, anywhere. G GS PPA Compact and lightweight Portable type with a lightweight of only about 100 g (unit 50 g, battery 50 g)

More information

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly. Components preparation and pressure adjustment ABP Overview ABP is a component that enables boosting by s only up to twice primary pressure (.0MPa max.) in combination with using air tank but not using

More information

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications Outstanding performance in extremely low pressure and low pressure ranges from 0.003 to. Realizing high performance, energy saving, and compact size. Realize precise pressure control in a pressure range

More information

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cart., Size 2 4 Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 5 bar Direct acting, electrically operated 1 Description inverse proportional pressure-relief valves are direct acting screw-in cartridges

More information

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9 Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Fluid Proof pressure Operating pressure differential range (Difference between tank pressure and line pressure) Vibration resistance

More information

Process Pump. Series PAF3000/Series PAF5000

Process Pump. Series PAF3000/Series PAF5000 Process Pump Series 3/Series The excellent corrosion resistance is achieved due to the new PFA wetted material construction! PPS/PFA dual construction, withstand pressure and heat cycle performance have

More information

One-touch Fittings Manifold. Porting. One-touch fitting. One-touch fitting. One-touch fitting. One-touch fitting. One-touch fitting.

One-touch Fittings Manifold. Porting. One-touch fitting. One-touch fitting. One-touch fitting. One-touch fitting. One-touch fitting. One-touch Fittings Manifold Series KM RoHS Compact piping possible. Manifold piping possible. Many varieties (0 types) are available. s give the most efficient operation. KM1 KM1 orting Rc female thread

More information

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A Air Consumption 70% Down New Product Precision Regulator Air Saving Type RPE Series PRECISION REGULATOR RPE SERIES Large Air Saving CC-1072A Air Consumption 70% Down. New Type Eco-friendly Precision Regulator

More information

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08 Prop. -Way Pressure-Reducing Cart., Size / SAE 8 Q max = 1 l/min (4 gpm), p max = bar (6 psi) Direct acting, electrically operated 1 Description proportional -way pressure-reducing cartridges are size

More information

3-Way Safety Block DSV

3-Way Safety Block DSV 3-Way Safety Block DSV DSV 10 - M DSV 10 - M - T-ball DSV 10 - EY 1. Description 1.1. GENERAL The 3-way safety block is used to shut off and discharge hydraulic accumulators or consumers. It complies with

More information

MANUAL KPS Pressure Control Valve

MANUAL KPS Pressure Control Valve TetraTec Instruments GmbH Gewerbestrasse 8 71144 Steinenbronn Deutschland E-Mail: info@tetratec.de Tel.: 07157/5387-0 Fax: 07157/5387-10 MANUAL Pressure Control Valve *** VERSION 1.0 *** Update: 17.11.2006

More information

EXH. Specifications. Descriptions. Min. working pressure MPa

EXH. Specifications. Descriptions. Min. working pressure MPa Functional explanation Primary pressure flowed from passes through check valve on side, and flows in chamber A and B. Primary pressure also passes through pressure adjustment section and switching valve,

More information

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Installation, operating and maintenance Instructions for Seemag bypass level indicator Issue: S Date: 05-09-14 Type G35 General information The Seetru bypass magnetic level indicator, abbreviate SEEMAG, serves to show the filling level of fluids in tanks, basins, tubes etc. The Seemag operates

More information

Proportional pressure regulators VPPM

Proportional pressure regulators VPPM Key features LED indicators Control elements Display Plug socket with cable Venting at both ends Manifold block Sub-base valve Assembly repositionable by 180 In-line valve H-rail mounting Compressed air

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation 2/2- and 3/2-way cartridge solenoid valve 2/2- und 3/2-Wege-Cartridge-Magnetventil Électrovanne cartridge à 2/2 ou 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation We reserve the

More information

Intrinsically safe solenoid valves on/off controls - ATEX certification

Intrinsically safe solenoid valves on/off controls - ATEX certification www.atos.com Table E130-17/E Intrinsically safe solenoid valves on/off controls - ATEX certification valve body valve spool intrinsically safe solenoid electrical connector manual override DHW-0611/WP/6

More information

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K Modular Type Regulator Series R Regulator Series R Model R M5 x.8 ccessory R2 /8, /4 R /4, 3/8 R3 /4, 3/8 R4 /4, 3/8, /2 Pages 36 through 4 Regulator with back flow mechanism Series RK R4-6 R5 R6 R2K RK,

More information

Series VBA1110 to 4200

Series VBA1110 to 4200 Booster Regulator Series 0 to 4200 Specifications increase ratio Max. supply pressure Set pressure range Ambient and fluid temperature Lubrication Installation adjustable mechanism 0-02 400-04 Handle operated

More information

MULTIPOL - VDMA. PNEUMATIC SPOOL VALVE ISLANDS VDMA ISO 02 - ISO 01 (G1/8 - G1/4) designed for connection to a PLC by multiwire cable

MULTIPOL - VDMA. PNEUMATIC SPOOL VALVE ISLANDS VDMA ISO 02 - ISO 01 (G1/8 - G1/4) designed for connection to a PLC by multiwire cable P8.G.R PEUATIC SPOOL VALVE ISLADS VDA - ISO - ISO (G/8 - G/) designed for connection to a PLC by multiwire cable ULTIPOL - VDA IPUT IPUT OUTPUT OUTPUT OUTPUT IPUT IPUT ULTIPOL - VDA Pneumatic spool valve

More information

Technical Data. Dimensions

Technical Data. Dimensions 00 Model Number Features mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,

More information

Inductive Linear Displacement Transducers Model IW 260 Measuring strokes: 80 mm, 170 mm, 240 mm, 360 mm

Inductive Linear Displacement Transducers Model IW 260 Measuring strokes: 80 mm, 170 mm, 240 mm, 360 mm Inductive Linear Displacement Transducers Model IW 260 Measuring strokes 80, 170, 240, 360 Document no. IW 100 HE Date 1.07.201 Contactless, robust sensor system Infinite resolution, no hysteresis Calibrated

More information

Compressed Air Cleaning Filter Series

Compressed Air Cleaning Filter Series Compressed ir Cleaning Filter Series M /FF Series For Water Droplet, Solid/Oil Separation and Deodorization Modular connection, Space-saving design, Labor-saving in piping! Uses the same spacer as the

More information

No.IL02-OM00011-A PRODUCT NAME LOCK UP VALVE. MODEL/ Series IL201 IL211

No.IL02-OM00011-A PRODUCT NAME LOCK UP VALVE. MODEL/ Series IL201 IL211 No.IL02-OM00011-A PRODUCT NAME LOCK UP VALVE MODEL/ Series IL201 IL211 Table of Contents Instructions for your Safety 1~2 1. Summary 3 2. Specification 3 3. Operation Principle 3~4 4. Transportation and

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens AG 07 Overview Function U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/ Equipotential bonding Diaphragm The pressure

More information

Valves, manually operated

Valves, manually operated Valves, manually operated Valves, manually operated Key features VHEM-P K/O-3-PK-3 H-3-¼-B KH/O-3-PK3 TH/O-3-PK3 VHEM-L F-3-¼-B Innovative Versatile Reliable Easy to mount Small and compact for a wide

More information

GM-7000 Series CE Approved Gas Control Valve

GM-7000 Series CE Approved Gas Control Valve Installation Instructions GM-7000 Issue Date November 9, 2012 GM-7000 Series CE Approved Gas Control Valve Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing

More information

Angle Seat Valve / Air Operated Type

Angle Seat Valve / Air Operated Type Angle Seat Valve / Air Operated Type RoHS Steam Can be used with air or water Low pressure loss due to angle seat structure! Reduced leakage with rubber seal! Long service life 3 5 1 million cycles (Steam)

More information

Precision pressure regulators LRP/LRPS

Precision pressure regulators LRP/LRPS Precision pressure regulators LRP/LRPS q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement

More information

Valve Proving System VDK 200 A S02

Valve Proving System VDK 200 A S02 Valve Proving System VDK 200 A S02 Valve proving system with the following approvals. UL Recognized File # MH17004 CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter

More information

How to Order RM0 0 Z. IN/OUT fitting type Metric size Inch size Straight Elbow Straight Elbow Straight Elbow Straight Elbow ø ø ø ø ø ø ø ø ø/ ø/ ø/ ø

How to Order RM0 0 Z. IN/OUT fitting type Metric size Inch size Straight Elbow Straight Elbow Straight Elbow Straight Elbow ø ø ø ø ø ø ø ø ø/ ø/ ø/ ø Series RM/ End lock RME Port Plug End block End block type Mounting position L Left side R Right side L side end block 0. L VVQ0000 Single unit regulator / Port plug for regulator block ø0 0 Options Note

More information

Technical Data Sheet TI-F50 Locking Units series KFH

Technical Data Sheet TI-F50 Locking Units series KFH English translation of German original Locking Units series KF Further important practical advice is given in Operating Manual BA-F50., Rod diameter 18 mm 50 mm øz 8 L 2 6 x 6 0 min. 4x30 KF 18 to KF 32,

More information

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH THIS MANUAL IS INTENDED FOR TECHNICAL STAFF IN CHARGE OF THE INSTALLATION, THE OPERATION AND THE MAINTENANCE OF THIS PRODUCT CAUTION!

More information

Zelio Relays RSL Slim Interface Plug-In Relays

Zelio Relays RSL Slim Interface Plug-In Relays Zelio Relays RSL Slim Interface Plug-In Relays Catalog 8501CT0901 2009 Class 8501 CONTENTS Description............................................. Page Introduction.................................................3

More information

MASS-STREAM TM Instruction Manual. D-6200 Analog Mass Flow Meters / Controllers

MASS-STREAM TM Instruction Manual. D-6200 Analog Mass Flow Meters / Controllers MASS-STREAM TM Instruction Manual D-6200 Analog Mass Flow Meters / Controllers Doc. No.: 9.17.112A Date: 17-03-2017 ATTENTION Before installing and operating the instrument it is strongly recommended that

More information

Expert Hydrostatic Level Transmitters

Expert Hydrostatic Level Transmitters Expert Hydrostatic s General Features MJK Expert hydrostatic level transmitters are designed for level measurement by submerging the transmitter in open channels, drains and tanks. Expert hydrostatic level

More information

GasSense NDIR User Manual

GasSense NDIR User Manual INDEX INDEX... 1 1. OVERVIEW... 2 2. TECHNICAL DATA... 3 3. SPECIFICATIONS... 4 4. PRODUCT DESCRIPTION... 5 4.1 Mechanical details... 5 4.2 Piping... 7 4.3 Connections... 7 5. INSTALLATION... 10 6. CALIBRATION

More information

2/2-way proportional valve

2/2-way proportional valve 2/2-way proportional valve General purpose 0... 12 bar DN 0.8... 2.0 mm 1/8 or sub-base version Type 2824 can be combined with Type 805 Digital control electronics DIN-rail version Type 07 Cable plug Typ

More information

Filter regulator. Accessory. Description. Symbol. B With bracket With round. Port size. (Without limit indicator) Body size.

Filter regulator. Accessory. Description. Symbol. B With bracket With round. Port size. (Without limit indicator) Body size. eries ow to Order opper, fluorine and silicon-free + Low particle generation il ote 1) ote 2) part no. lean series hread type Rc racket assembly ote ) ote 9) 1.0a 0.2a / -20 49-01 49-2-01 ilter regulator

More information

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. Supplied with an electric input signal of 4 to 20

More information

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications. Rated operating distance s n 5 mm 0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching

More information

Position switches FP series

Position switches FP series A Position switches FP series Selection diagram 0 08 8 9 0 0 0 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fiber glass rod gasket sphere sphere adjustable lever safety adjustable lever

More information

LMU100/200 Series. Standard Specifications

LMU100/200 Series. Standard Specifications Mist Spray Unit MU/ Series Intermittent spray to cutting and press gear chains, etc. Standard Specifications Inlet air Oil tank set range Oil Dynamic viscosity of oil ( C) Oil tank capacity (cm ) mbient

More information

Ambient Capacitance Gauge

Ambient Capacitance Gauge Ambient Capacitance Gauge KJLC ACG Operating Manual Incl. EU Declaration of Conformity tkna57e1 (2017-03) 1 Product Identification In all communications with Kurt J. Lesker Company, please specify the

More information

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies We reserve the right to make technical changes without notice. Technische Änderungen vorbehalten. Sous réserve de modifications techniques.

More information

TURQUOISE SWITCHES ABJ (BJ) SWITCHES

TURQUOISE SWITCHES ABJ (BJ) SWITCHES Ultra-miniature Size Sealed Switches TURQUOISE SWITCHES ABJ (BJ) SWITCHES Terminal type Mounting hole 2.3 mm type FEATURES Ultra-miniature size, High sealing performance sealed switches Elastomer double

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Bypass MFC with capillary technology for nominal flow rates from 5 ml N /min to 15 l N /min Applicable for aggressive gases Compact design and digital communication

More information

Digital relief valves D-CG

Digital relief valves D-CG Digital relief valves D-G unctional Symbols D-G- Specifications Size Maximum working pressure Rated flow Maximum flow Maximum adjustable pressure Ma Minimum control pressure Hysteresis Repeatability emperature

More information

JUMO dtrans p30 Pressure Transmitter

JUMO dtrans p30 Pressure Transmitter 609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +49 661 600-0 Fax: +49 661 600-607 Phone: +44 179 6 55 Data Sheet 40466 Page 1/6 JUMO dtrans p0 Pressure Transmitter General application Pressure

More information

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10 / ED VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES OPERATING PRINCIPLE The VPPL are variable displacement axial-piston pumps with variable swash plate, suitable for applications

More information

Relative pressure switch type 521

Relative pressure switch type 521 Relative pressure switch type 521 Pressure range 0... 2.5 600 bar The compact type 521 pressure switch is based upon the Huba Control developed thick film technology where the pressure measuring cell is

More information

Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification ATEX, IECEx, EAC

Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification ATEX, IECEx, EAC www.atos.com Table -2/E Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification TEX, IEEx, E valve body spool ex-proof solenoid ex-proof inductive

More information

sitrans p Operating Instructions (de/en) Edition 03/2004

sitrans p Operating Instructions (de/en) Edition 03/2004 (de/en) Edition 03/2004 sitrans p Messumformer für Food, Pharma und Biotechnik Transmitters for food, pharmaceuticals and biotechnologgy 7FM8010 Contents Information for the operator...27 Important security

More information

Programmable pressure and temperature transmitters PTM/RS485

Programmable pressure and temperature transmitters PTM/RS485 Programmable pressure and temperature transmitters PTM/RS485 Version: 03-28-2012 Technical Specifications Pressure measuring range (bar) 0.1... 0.5 > 0.5 2 > 2 25 Overpressure 3 bar 3 x FS ( 3 bar) 3 x

More information

VBA1110 to 4200 VBA /4 (IN/OUT) 1/4

VBA1110 to 4200 VBA /4 (IN/OUT) 1/4 Booster Regulator to 4200 Specifications Pressure increase ratio Max. supply pressure Set pressure range Ambient and fluid temperature Lubrication Installation Pressure adjustable mechanism -02 Fluid Proof

More information

GM Series Dual-Block Multi-Function Gas Control Valves

GM Series Dual-Block Multi-Function Gas Control Valves Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin GM Issue Date 0297 GM Series Dual-Block Multi-Function Gas Control Valves Figure 1: GM Series

More information

Pneumatic spool valve islands

Pneumatic spool valve islands neumatic spool valve islands A7.GB.R MGA SOOL VALV ISLANDS MGA pneumatic spool valve islands offer maximum performance along with flexibility, easy installation and simple operation. Due to their design,

More information

Directional Controls

Directional Controls Vickers Directional Controls Directional Control Valves DG3V-3-*-60 Hydraulic Operated DG17V-3-*-60 Lever Operated DG18V-3-*-60 Air Operated DG20V-3-*-60 Cam Operated DG21V-3-*-60 Plunger Operated CETOP

More information

Programmable Submersible Level Transmitters

Programmable Submersible Level Transmitters Programmable Submersible Level Transmitters PTM/N/RS485 CUSTOMER BENEFITS High flexibility due to scalalbe pressure range Digital (RS485) and analogue (4-20mA) output signal in one sensor Available as

More information

Vickers. Filters. Reservoir Vent Filters. Spin-on Air Filters & Adaptors. Rev. 3/98

Vickers. Filters. Reservoir Vent Filters. Spin-on Air Filters & Adaptors. Rev. 3/98 Vickers Filters Reservoir Vent Filters Spin-on Air Filters & Adaptors Rev. 3/98 73 Introduction Prevent Airborne Ingression A key element of contamination control is reservoir vent filtration. Reservoir

More information

DPI 610/615 Series. Druck Portable. Pressure Calibrators. GE Sensing. Features. Setting the Standard for Portable. Pressure Calibrators

DPI 610/615 Series. Druck Portable. Pressure Calibrators. GE Sensing. Features. Setting the Standard for Portable. Pressure Calibrators Features Ranges -14.7 to 10,000 psi Accuracy from 0.025% full scale (FS) Integral combined pressure/vacuum pump Dual readout: input and output 4 to 20 ma loop test: auto step and ramp Intrinsically safe

More information

Solenoid Valves VUVG Overview

Solenoid Valves VUVG Overview Solenoid Valves VUVG Overview Universal valve Combination of basic valve and E-boxes Width 10 mm and 14 mm In-line valves VUVG-L and VUVG-S Sub-base valves VUVG-B Internal or external pilot air supply

More information

Series variation. Silencer. High damping effect and 2 types of materials. Applicable cylinder bore size (mm) Effective sectional area (mm 2 )

Series variation. Silencer. High damping effect and 2 types of materials. Applicable cylinder bore size (mm) Effective sectional area (mm 2 ) Series variation High damping effect and types of materials Model / appearance Metering valve with silencer Model no. SMW-6 SMW-8 FMS-M SMW- SMW- (R) M M /8 / /8 / / / / 6 8 Effective sectional area (mm

More information

Orifice Plate Flow Meter

Orifice Plate Flow Meter Orifice Plate Flow Meter FOFT Measuring Principle The principle of measuring the differential pressure is based on the fact that a differential pressure is created across that section of a pipe where its

More information

How to specify a product. Process Sensors and Mechanical Instruments

How to specify a product. Process Sensors and Mechanical Instruments How to specify a product Process Sensors and Mechanical Instruments Keep the overview. Here is some guideline information on how to specify our products. Intended as supplementary help to specification

More information

Easy to operate even for biginners. Set up the number of test. Possible to select from 1 to times

Easy to operate even for biginners. Set up the number of test. Possible to select from 1 to times With a force gauge and attachments, compression/tensile/peeling tests are possible up to 1000N/2500N. It provides consistent testing speed and direction, offering highly accurate test results. MX2-2500N

More information

EASIDEW TRANSMITTER with Current Source Output

EASIDEW TRANSMITTER with Current Source Output EASIDEW TRANSMITTER with Current Source Output INSTALLATION, OPERATION AND MAINTENANCE MANUAL Issue March 2002 2 TABLE OF CONTENTS SECTION PAGE 1. INTRODUCTION 3 1.1 General 3 1.2 Ceramic Sensing Element

More information

UNIK 5600/5700 Marine Certified Pressure Sensing Platform

UNIK 5600/5700 Marine Certified Pressure Sensing Platform GE Measurement & Control UNIK 5600/5700 Marine Certified Pressure Sensing Platform The new UNIK 5600/5700 carries marine certification for most zones on-board ship, as well as Intrinsically Safe certifications.

More information

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1 Dry 131h 1. DESCRIPTION The Viking Model G-1 Maintenance Air Compressor is an electric motor-driven, aircooled, single-stage, oil-less compressor. The unit is equipped with a check valve and provides a

More information

Moisture Control Tube

Moisture Control Tube Moisture Control Tube (Moiscon) Prevents! Prevents condensation in piping for small cylinders/air grippers. Diffuses water vapor in the piping to the outside! vapor vapor vapor Moisture control tube General

More information

SECTION 9 CLASSIC SERIES PUMPS

SECTION 9 CLASSIC SERIES PUMPS SECTION CLASSIC SERIES PUMPS 07 EDCO USA www.edcousa.net : CLASSIC PUMPS DUAL BASE CLASSIC PUMPS TRIPLE BASE CLASSIC PUMPS QUAD BASE CLASSIC PUMPS General Information : Classic Pumps: How To Order :4 Classic

More information

P900. P900, Datenblatt Seite 1 DESCRIPTION

P900. P900, Datenblatt Seite 1 DESCRIPTION , Datenblatt Seite 1 Field proven rugged construction High overpressure capability High reliability for demanding environments Application specific customization Excellent media compatibility Shock and

More information

Safety. Operating instructions. Pressure switches for gas DG..H, DG..N. Pressure switch for gas DG..I DANGER. Contents WARNING CAUTION

Safety. Operating instructions. Pressure switches for gas DG..H, DG..N. Pressure switch for gas DG..I DANGER. Contents WARNING CAUTION 05 Elster GmbH Edition 095 Translation from the German 057 D F L I E DK S P GR TR CZ PL RUS H wwwdocuthekcom Operating instructions Pressure switches for gas DGH, DG Pressure switch for gas DGI Cert version

More information

Gas Pressure Switch for DMV safety shutoff valves

Gas Pressure Switch for DMV safety shutoff valves Gas Switch for DMV safety shutoff valves GAO-A GMH-A GML-A UL Listed UL 353 File # MH 1668 CSA Certified CSA C. No. LR 53 File # 0157 FM Approved Class 3510, 3530 File # J.I. 1Y9A9.AF Commonwealth of Massachusetts

More information

Programmable pressure and temperature transmitters PTM/RS485

Programmable pressure and temperature transmitters PTM/RS485 Programmable pressure and temperature transmitters PTM/RS485 Version: 26.06.2014 Technical Specifications Pressure measuring range (bar) 0.1... 0.5 > 0.5 2 > 2 25 Overpressure 3 bar 3 x FS ( 3 bar) 3 x

More information

User Manual. Quantos Automated Dosing Liquid Module

User Manual. Quantos Automated Dosing Liquid Module User Manual Liquid Module 1 Safety Information 1.1 Definition of warnings and symbols Signal Words WARNING for a hazardous situation with medium risk, possibly resulting in severe injuries or death if

More information

GS-20/25 and GS-40/45 Series Single-block Multi-function Gas Control Valves

GS-20/25 and GS-40/45 Series Single-block Multi-function Gas Control Valves Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin GS-20/25 GS-40/45 Issue Date 1298 GS-20/25 and GS-40/45 Series Single-block Multi-function Gas

More information

Solenoid valve type EVR for Hydrocarbons

Solenoid valve type EVR for Hydrocarbons MAKING MODERN LIVING POSSIBLE Technical brochure Solenoid valve type EVR for Hydrocarbons EVR for Hydrocarbons is a direct or servo operated solenoid valve especially designed for liquid, suction, and

More information

Easy to operate. Wide space

Easy to operate. Wide space With a force gauge and attachments, compression/tensile/pealing tests are possible up to 1000N/2500N. It provides consistent testing speed and direction, offering highly accurate test results. MX2-2500N

More information

Technical Manual. Liquid Level Transmitter CT801-LB/S

Technical Manual. Liquid Level Transmitter CT801-LB/S CT801-LB/S Technical Manual SAS au Capital de 2 158 244-444 871 933 R.C.S. Bourges - APE : 2651B Headquarter : 9, rue Isaac Newton - 18000 Bourges - France Technical Manual CT801-LB/S 1 st Edition Released

More information

KEG PUMP. Range of Electric Keg Pumps

KEG PUMP. Range of Electric Keg Pumps KP KEG PUMP Range of Electric Keg Pumps Electric Keg (Drum) Pumps for Grease KEG PUMP Versatile range of Interlube electric grease pumps for industrial and off-road applications The KP keg pump is available

More information

MPM280 Piezoresistive OEM Pressure Sensor

MPM280 Piezoresistive OEM Pressure Sensor MPM280 Piezoresistive OEM Pressure Sensor MPM280 Pressure Sensor (V2.0) Features Pressure range 0kPa~20kPa 100MPa; Gauge, absolute and sealed gauge; Constant current / Constant Voltages power supply; Isolated

More information

OXYGEN MONITORING SYSTEM OMS

OXYGEN MONITORING SYSTEM OMS User Manual OXYGEN MONITORING SYSTEM OMS 420 Read and observe before commissioning! Ex Situ oxygen analyzer based on ZrO 2 sensor ENGLISH Caution! Please inspect in the presence of the transporting agent

More information

Clean Gas Filter. SF Series. Cartridge Type/Disposable Type IDFA IDFB IDH ID IDG IDK AMG AFF AM AMD AMH AME AMF ZFC SF SFD LLB AD GD SFC10

Clean Gas Filter. SF Series. Cartridge Type/Disposable Type IDFA IDFB IDH ID IDG IDK AMG AFF AM AMD AMH AME AMF ZFC SF SFD LLB AD GD SFC10 Clean Gas Filter SF Series Cartridge Type/Disposable Type Disposable type SFC0 Disposable type SFB30 Cartridge type SFA0 SFA20 SFA30 HAA HAW AT IDU FS A B IDH ID IDG IDK AMG AFF AM AMD AMH AME AMF ZFC

More information

KMT. Thermal Mass Flowmeter. for compressed air and gases. Measuring range: Nm³/h Nm³/h

KMT. Thermal Mass Flowmeter. for compressed air and gases. Measuring range: Nm³/h Nm³/h Thermal Mass Flowmeter for compressed air and gases measuring monitoring analysing KMT Measuring range: 0.32... 63 Nm³/h - 263.4... 263350 Nm³/h Accuracy: ± 1.5% of reading + 0.5% of full scale ( DN 50)

More information

SPOOL VALVES. ISO 15407/1 - Sizes Series PA568-GB-R3. All leafl ets available at:

SPOOL VALVES. ISO 15407/1 - Sizes Series PA568-GB-R3. All leafl ets available at: SPOOL VLVS ISO 07/ - Sizes 0-0 Series 8-9 P68-GB-R ll leafl ets available at: www.ascojoucomatic.com FTURS These spool valves which comply with the VDM 6 standard offer the advantage of being smaller than

More information

Process Pump. The excellent corrosion resistance is achieved due to the new. Series PAF3000/Series PAF5000

Process Pump. The excellent corrosion resistance is achieved due to the new. Series PAF3000/Series PAF5000 Process Pump Series F3/Series F RoHS The excellent corrosion resistance is achieved due to the new PFA wetted material construction! PPS/PFA dual construction, withstand pressure and heat cycle performance

More information

(1) Name of tube (2) Tube dia. (O.D./I.D.) (3) Tube length. (4) Tube color. Model UD0425. UD1290 O.D. I.D. (mm) UD1075 UD0860 UD

(1) Name of tube (2) Tube dia. (O.D./I.D.) (3) Tube length. (4) Tube color. Model UD0425. UD1290 O.D. I.D. (mm) UD1075 UD0860 UD The polyurethane tube, featuring excellent flexiblity, helps compact piping requiring small bending radius. The useful cut marks at 500mm interval are printed on the tube. Model UD0425 UD0640 UD0860 UD1075

More information

PRODUCT SPECIFICATION FOR APPROVAL

PRODUCT SPECIFICATION FOR APPROVAL FARNELL INST UK Issue : Date of issue : Mar 08,2010 Classification: New Change PRODUCT FOR APPROVAL Product Description : Product Part Number : (Panasonic Part Number : ) Country of Origin : Malaysia (It

More information

Automatic Isokinetic Sampler. ST5 Evo

Automatic Isokinetic Sampler. ST5 Evo Automatic Isokinetic Sampler ST5 Evo Automatic Isokinetic Sampler ST5 Evo Moreover, in case of pump failure, the CU can work with a spare Dado PU unit or with any pump capable to supply the needed flowrate,

More information

SP11. Instructions for installation and operation. EN - English

SP11. Instructions for installation and operation. EN - English EN - English Instructions for installation and operation Pressure transducer METPOINT PRM SP11 10-054 Dear customer, Thank you for deciding in favour of the METPOINT PRM SP11 pressure transducer. Please

More information

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler. Exercise 5-2 Bubblers EXERCISE OBJECTIVE Learn to measure the level in a vessel using a bubbler. DISCUSSION OUTLINE The Discussion of this exercise covers the following points: Bubblers How to measure

More information

EcoPRO-Series 4-20mA SUBMERSIBLE PRESSURE TRANSMITTER INSTRUCTIONS

EcoPRO-Series 4-20mA SUBMERSIBLE PRESSURE TRANSMITTER INSTRUCTIONS EcoPRO-Series 4-20mA SUBMERSIBLE PRESSURE TRANSMITTER INSTRUCTIONS EcoPRO-Series 4-20mA SUBMERSIBLE PRESSURE TRANSMITTER INSTRUCTIONS 9001:2008 ISO CERTIFIED COMPANY Table of Contents Introduction - EcoPRO-Series

More information

Additel 780 Series Pressure Controller

Additel 780 Series Pressure Controller Additel 780 Series Pressure Controller Pressure / Process Calibration Equipment Pressure ranges from vacuum to 3,000 psi (200 bar) Removable interchangeable intelligent sensors Precision accuracy of 0.005%

More information

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases P r o d u c t i n f o r m at i o n EuroFID Total Hydrocarbon Analyzer Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases Proven Analyzer Technology Measuring total

More information

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073 Operating instructions Safety Rope Emergency Stop Switches UK ZB0052 / ZB0053 ZB0072 / ZB0073 7390878 / 02 03 / 2011 Contents 1 Safety instructions...3 2 Installation / set-up...4 2.1 Applications...4

More information