Multistage Ejector Series ZL

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "Multistage Ejector Series ZL"

Transcription

1 Multistage Ejector Series. Energy-saving, large flow rate, 3 stage diffuser construction Suction flow rate increased 5% and air consumption reduced % with 3 stage diffuser construction (ersus ø.3, one stage model) acuum pressure sensor With adaptor for vacuum acuum pressure stage performance Series Q Q Q3 Q Q Q3 stage performance 5% suction flow rate increase 3 stage performance Suction flow rate Diffusers stacked and integrated Compact size and large flow rate (Twice the flow rate of the ) With vacuum pressure gauge Digital vacuum pressure switch Rated pressure range:. to. ka 3-step setting 3 S ZSE3A Release valve Supply valve Release flow rate adjusting needle Suction flow rate (l/min (ANR)) With One-touch fittings Makes piping work easy ( only) Air consumption (l/min (ANR)) 63 6 Built-in silencer ort exhaust A Z S AM AE HE ush Adjust to set-value with buttons. ush Finish setting ower-saving function ower consumption is reduced by turning off the monitor. (Reduce power consumption by up to %.) For series ZSE3A, refer to the separate catalog (CAT.ES-7) for details. Series ariations Series Maximum suction flow rate (l/min (ANR)) Air consumption (l/min (ANR)) Built-in silencer ort exhaust With digital vacuum pressure switch With supply and release valves With supply valve ZSE3A acuum pressure sensor option acuum pressure gauge acuum adapter

2 Multistage Ejector Series How to Order Without valve K 5 M Z Nozzle diameter. mm Exhaust type Built-in silencer ort exhaust (EXH) thread type (ort exhaust only) Note 3) The thread ridge shape is conforming to G thread standard (JIS B3), but other shapes are not conforming to ISO63 and ISO79. F N T Rc/ G/ (3) /-4 NT /-4 NTF Supply valve/release valve combination K K With supply and release valves With supply valve Lead wire specifications (Applicable only when the vacuum pressure sensor specification is D for digital pressure switch for vacuum) L Lead wire with connector (Length m) Unit specifications (Applicable only when the vacuum pressure sensor specification is D for digital pressure switch for vacuum) M With unit switching function SI unit only With unit switching function (Initial value psi) Note ) W/ unit switching function is not permitted to sell for the domestic use in Japan, because the new Weight and Measure Act has been implemented since October, 99. Note ) Fixed unit: ka Rated voltage DC specifications S 5 R 3 AC specifications (5/6 Hz) 3 4 [5] [3] G H L LN LO M MN MO Grommet L plug connector M plug connector Electrical entry S Z U Lead wire length.3 m Lead wire length.6 m Lead wire length.3 m Without lead wires Without connector Lead wire length.3 m Without lead wires Without connector Light/Surge voltage suppressor Without light/surge voltage suppressor With surge voltage suppressor With light/surge voltage suppressor With light/surge voltage suppressor (Non-polar type) Type U is 4 or DC only. Since surge voltage is prevented by a rectifier in the case of AC, there is no type S. D Non-locking push type Locking slotted type Manual override Output specifications (Applicable only when the vacuum pressure sensor specification is D for digital pressure switch for vacuum) N A B C D E F acuum pressure sensor GN G D NN open collector output N open collector output NN open collector outputs N open collector outputs NN open collector output + Analog voltage output NN open collector output + Analog current output N open collector output + Analog voltage output N open collector output + Analog current output None acuum port adaptor Rc /8 acuum pressure gauge Digital pressure switch for vacuum 68

3 Multistage Ejector Series Standard With vacuum pressure gauge Adapter ort exhaust Ejector Specifications Model Nozzle diameter Maximum suction flow rate Air consumption Maximum vacuum pressure Maximum operating pressure Supply pressure range Standard supply pressure Operating temperature range Supply/Release alve Specifications art no. Type of valve actuation Fluid Operating pressure range Internal pilot type Ambient and fluid temperature Response time (For.5 Ma) () Maximum operating frequency Manual override ilot exhaust type Lubrication Mounting position Impact/ibration resistance () Enclosure Option Specifications. mm l/min (ANR) 63 l/min (ANR) 84 ka.7 Ma. to.5 Ma.4 Ma 5 to 5 C SYJ54- -S N.C. Air. to.5 Ma 5 to 5 C 5 ms or less 5 Hz Non-locking push type/locking slotted type ilot valve individual exhaust, Main valve/ilot valve common exhaust Not required Unrestricted 5/3 m/s Dust proof Note ) Based on JIS B dynamic performance test. (coil temperature C, at rated voltage, without surge voltage suppressor) Note ) Impact resistance: No malfunction when tested with a drop tester in the axial direction and at a right angle to the main valve and armature, one time each in both energized and deenergized states. (initial value) ibration resistance: No malfunction when tested with one sweep of 45 to Hz in the axial direction and at a right angle to the main valve and armature, one time each in both energized and deenergized states. (initial value) Note 3) Refer to Best neumatics No. for details on valves. acuum ressure Gauge Specifications art no. GZ3S Fluid Air ressure range to ka Scale range (Angular) 3 Accuracy ±3% F.S. (Full span) Class Class 3 Operating temperature range to 5 C Material Housing: olycarbonate/abs resin A Z S AM AE HE JIS Symbol Standard Mass (Basic) ort exhaust Digital pressure switch for vacuum (Excluding lead wire) Digital pressure switch for vacuum (Including 3 cores lead wire) Digital pressure switch for vacuum (Including 4 cores lead wire) alve (per pc.) 45 g + g +43 g +8 g +85 g +45 g 69

4 Series acuum ressure Switch Unit/Digital ressure Switch for acuum: ZSE3A-- - -X55 How to Order ZSE3A X55 Symbol N A B C D E F Output specifications Output Analog output Type oint oltage Current NN N NN N NN NN N N Option (Operating manual specifications) Y Operating manual (Leaflet) Without operating manual Option (Connector/Lead wire specifications) L Without lead wire Lead wire with connector (Length m) Display unit With unit display switching function M Fixed SI unit With unit display switching function (Initial value psi) Specifications Rated pressure range Set pressure range Withstand pressure Minimum unit setting Applicable fluid ower supply voltage Current consumption Switch output Maximum load current Maximum applied voltage Residual voltage Response time Short circuit protection Repeatability Hysteresis mode Window comparator mode Hysteresis Analog output Output voltage (Rated pressure range) Linearity Output impedance Output current (Rated pressure range) Linearity Load impedance. to. ka. to 5. ka 5 ka. ka Air, Non-corrosive gas, Non-flammable gas to 4 DC ±% (with power supply polarity protection) 4 ma (at no load) NN or N open collector output NN or N open collector outputs (selectable) 8 ma 8 (at NN output) or less (with load current of 8 ma).5 ms or less (with anti-chattering function:,, 5,, ms) Yes ±.% F.S. ± digit ariable ( to variable) to 5 ±.5% F.S. ±% F.S. or less Approx. kω 4 to ma ±.5% F.S. ±% F.S. or less Maximum load impedance: ower supply voltage : 3 Ω, ower supply voltage 4 : 6 Ω Minimum load impedance: 5 Ω Display 4-digit, 7-segment, -color LCD (Red/Green) Sampling cycle: 5 times/sec. Display accuracy ±% F.S. ± digit (Ambient temperature of 5 C) Indicator light Lights up when switch output is turned ON. (OUT: Green, OUT: Red) Enclosure I4 Operating temperature range Operating: to 5 C, Stored: to 6 C (No freezing or condensation) Operating humidity range Operating/Stored: 35 to 85% RH (No condensation) Withstand voltage AC for minute between live parts and case Insulation resistance 5 MΩ or more between live parts and case (at 5 DC Mega) to 5 Hz at whichever is smaller of.5 mm amplitude or ibration resistance m/s acceleration, in X, Y, Z directions, for hours each Impact resistance m/s, in X, Y, Z directions, for hours each Temperature characteristics ±% F.S. (Based on 5 C) Oilproof heavy-duty vinyl cable, 3 cores ø3.5, m Lead wire 4 cores Conductor area:.5 mm (AWG6) Insulator O.D.:. mm Standards CE Marking, UL/CSA, RoHS compliance Note ) When analog voltage output is selected, analog current output cannot be used together. Note ) When analog current output is selected, analog voltage output cannot be used together. Environment resistance Note ) oltage output Note ) Current output 7

5 Multistage Ejector Series Exhaust Characteristics/Flow Characteristics/Time to Reach acuum Exhaust Characteristics acuum pressure (ka) Flow Characteristics acuum pressure (ka) Time to Reach acuum acuum pressure in tank (ka) Supply pressure (Ma) Exhaust Characteristics acuum pressure acuum pressure Suction flow rate Air consumption Suction flow rate (l/min (ANR)) Air consumption (l/min (ANR)) Supply pressure:.4 Ma Suction flow rate (l/min(anr)) 3 Tank capacity: l Supply pressure:.4 Ma acuum pressure reached 89ka 8ka 66ka 53ka 4ka 6ka 3ka Time to reach vacuum (S) <How to Read the Graph> The graphics indicate the time required to reach a vacuum pressure determined by adsorption conditions for workpieces, etc., starting from atmospheric pressure in a l sealed tank. Approximately 8.8 seconds are necessary to attain a vacuum pressure of 89 ka. acuum pressure (ka) Flow Characteristics acuum pressure (ka) Time to Reach acuum acuum pressure in tank (ka) acuum pressure Supply pressure (Ma) Supply pressure:.4 Ma Suction flow rate (l/min(anr)) Q Qmax Suction flow rate Suction flow rate Air consumption Tank capacity: l Supply pressure:.4 Ma acuum pressure reached 89ka 8ka Time to reach vacuum (S) Suction flow rate (l/min (ANR)) Air consumption (l/min (ANR)) 66ka 53ka 4ka 6ka 3ka <How to Read the Graph> The flow characteristics indicate the relationship between the vacuum pressure and the suction flow rate of the ejector, and show that when the suction flow rate changes the vacuum pressure also changes. In general, this indicates the relationship at the ejector s standard operating pressure. In the graph, max indicates the maximum vacuum pressure, and Qmax indicates the maximum suction flow rate. These are the values that are published as specifications in catalogs, etc. Changes in vacuum pressure are explained below. max. If the ejector s suction port is closed and sealed tight, the suction flow rate becomes and the vacuum pressure increases to the maximum (max).. If the suction port is opened and air is allowed to flow (the air leaks), the suction flow rate increases and the vacuum pressure decreases. (the condition of and Q) 3. If the suction port is opened completely, the suction flow rate increases to the maximum (Qmax), while the vacuum pressure then drops almost to (atmospheric pressure). When adsorbing work pieces which are permeable or subject to leakage, etc., caution is required as the vacuum pressure will not be very high. A Z S AM AE HE 7

6 Series Construction Without valve Comonent arts Replacement arts No Description art no. Note No. Description Material art no. Suction cover 9 Sound absorbing material B F -S Front cover Without valve Sound absorbing material A F (Set no. for 9, & ) End cover Suction filter E Body acuum sensor unit Nozzle Diffuser Detent plug Other than vacuum switch Lead wire cover acuum switch specifications Front cover B alve plate Needle Supply valve (N.C.) SYJ54- -S Release valve (N.C.) SYJ54- -S 7

7 Multistage Ejector Series Dimensions: Series (Without valve) 5 7 x ø5.4 Label Standard Rc / 35 ort exhaust (/-4 NTF, G / /-4 NT) acuum pressure gauge x ø5.4 4 A With vacuum pressure gauge -G acuum adapter Rc /8 x ø5.4 7 With vacuum adapter -GN Z 6 S Digital pressure switch for vacuum x ø5.4 With digital pressure switch for vacuum S AM -D (9) AE HE Air pressure supply port () Applicable tubing O.D. 6 acuum port () Applicable tubing O.D. Section A x ø MULTISTAGE EJECTOR 59.5 Label Section A/ With Digital ressure Switch for acuum -D (ZSE3A) x M4 Thread depth 8 () (5.8)

8 + + + Series Dimensions: Series (With alve) With supply valve and release valve -K L -D Digital pressure switch for vacuum x ø5.4 Manual override 3.5 Release valve S Supply valve Manual override Release flow rate adjusting needle Air pressure supply () port Applicable tubing O.D. 6 acuum () port Applicable tubing O.D. x ø5.4 (9) (6.8) Label 8 9 Circuit diagram (3) (5.8) x M4 x.7 Thread depth 8 () With supply valve -K L -D Blanking plate assembly (SYJ5--3A) Digital pressure switch for vacuum S Supply valve Circuit diagram 74

9 Multistage Ejector Series Standard With vacuum pressure gauge With digital vacuum pressure switch With adaptor ort exhaust GN G D Nozzle diameter. mm Exhaust specifications Built-in silencer ort exhaust acuum pressure sensor Model Nozzle diameter Maximum suction flow rate Air consumption Maximum vacuum pressure Maximum operating pressure Supply pressure range Standard supply pressure Operating temperature range None acuum port adaptor Rc /8 acuum pressure gauge Digital pressure switch for vacuum Ejector Specifications How to Order Lead wire specifications (Applicable only when the vacuum pressure sensor specification is D for digital pressure switch for vacuum) L Lead wire with connector (Length m) Unit specifications (Applicable only when the vacuum pressure sensor specification is D for digital pressure switch for vacuum) M Note ) W/ unit switching function is not permitted to sell for the domestic use in Japan, because the new Weight and Measure Act has been implemented since October, 99. Note ) Fixed unit: ka N A B C D E F ø. mm x l/min (ANR) 6 l/min (ANR) 84 ka.7 Ma. to.5 Ma.4 Ma 5 to 5 C With unit switching function SI unit only With unit switching function (Initial value psi) Output specifications (Applicable only when the vacuum pressure sensor specification is D for digital pressure switch for vacuum) NN open collector output N open collector output NN open collector outputs N open collector outputs NN open collector output + Analog voltage output NN open collector output + Analog current output N open collector output + Analog voltage output N open collector output + Analog current output A Z S AM AE HE Made to Order (Refer to page 78 for details.) JIS Symbol Standard Mass ort exhaust Digital pressure switch for vacuum (Excluding lead wire) Digital pressure switch for vacuum (Including 3 cores lead wire) Digital pressure switch for vacuum (Including 4 cores lead wire) alve (per pc.) 7 g +3 g +43 g +8 g +85 g +45 g 75

10 Series Construction Component arts Replacement arts No. Description Note No. Description Material art no. Suction cover Front cover A 9 Sound absorbing material A Sound absorbing material F F -S (Set no. for 9 & ) 3 End plate 4 Body 5 acuum sensor unit 6 Nozzle 7 Diffuser 8 Detent plug Lead wire cover Other than vacuum switch acuum switch specifications 76

11 S Multistage Ejector Series Dimensions: Series Air pressure supply port () Rc /8 acuum port() Rc 3/4 76 Standard Label 6 ort exhaust A acuum pressure gauge (EXH.) Rc 5 With vacuum pressure gauge -G acuum adapter Rc /8 7 With vacuum adapter -GN Z S Digital pressure switch for vacuum With digital pressure switch for vacuum -D MULTISTAGE EJECTOR Section A (9) x ø4.4 AM AE HE (4) x M5 x.8 Thread depth 6 () Section A/ With Digital ressure Switch for acuum -D 3 (5.8) 77

12 + + S Series Made to Order Specifications lease contact SMC for detailed specifications, dimensions and delivery. With Supply and Release alves alve oltage Electrical entry acuum pressure switch Electrical entry X3 With supply and release valves type with supply and release valves Dimensions SMC

13 Series Specific roduct recautions Be sure to read before handling. Refer to front matters 38 and 39 for Safety Instructions and pages 844 to 846 for acuum recautions. Operation of Ejector alves Caution. When the air supply valve is turned ON, vacuum is generated by the flow of compressed air from the nozzle to the diffuser. When the vacuum release valve is turned ON, the vacuum is quickly released as air passes through the release flow adjustment needle and flows to the vacuum port. Caution Caution Operating Environment. Avoid use exposed to direct sunlight. Solenoid alves (Series ). For specific product precuations on solenoid valves, refer to the solenoid valve (Series SYJ5) catalog. A Z S AM AE HE 79

CAT.E813- B. Multistage Ejector. Series ZL. New Models! ZL212 large flow rate type and ZL112 with valve.

CAT.E813- B. Multistage Ejector. Series ZL. New Models! ZL212 large flow rate type and ZL112 with valve. CAT.E813- B Multistage Ejector Series ZL New Models! ZL212 large flow rate type and ZL112 with valve. Multistage Ejector Series ZL112/212 Energy saving, large flow rate, 3 stage diffuser construction Suction

More information

Precision Regulator. Series Model Regulating pressure range Port size Page

Precision Regulator. Series Model Regulating pressure range Port size Page Precision Regulator Series // Basic Type Air Operated Type Series Model Regulating pressure range Page Series Series Series Series Series.5 to MPa. to MPa. to.8 MPa /8 55.5 to MPa. to MPa /4 55. to.8 MPa.

More information

435 psi (3.0 MPa) Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. Maximum supply pressure. Set pressure range.

435 psi (3.0 MPa) Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. Maximum supply pressure. Set pressure range. 435 psi (3.0 MPa) Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator RoHS Maximum supply pressure Set pressure range Stability 435 psi (3.0 MPa) 29 to 290 psi (0.2 to 2.0 MPa) Stepless control

More information

Proportional pressure regulators VPPE

Proportional pressure regulators VPPE Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/

More information

1.0. ISE70/71 Series CAT.ES A. MPa/1.6 MPa. 3-Screen Display High-Precision Digital Pressure Switch. Angled display.

1.0. ISE70/71 Series CAT.ES A. MPa/1.6 MPa. 3-Screen Display High-Precision Digital Pressure Switch. Angled display. 3-Screen Display High-Precision Digital Pressure Switch For Air 1.0 ISE70 ISE71 MPa/1.6 MPa RoHS IP67 It is possible to change the settings while checking the measured value. Main screen Measured value

More information

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly. Components preparation and pressure adjustment ABP Overview ABP is a component that enables boosting by s only up to twice primary pressure (.0MPa max.) in combination with using air tank but not using

More information

Vacuum Regulator. IRV10/20 Series. Weight reduced by. RoHS ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV

Vacuum Regulator. IRV10/20 Series. Weight reduced by. RoHS ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV Vacuum egulator IV0/ eries oh AJ A45 ingle ided Connections eries AX For ease of installation and panel mounting AM AM Integrated digital pressure switch for panel mounting I -A I (Made to Order) ingle

More information

KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media

KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media FEATURES 50 mbar to 400 bar, 5 to 6000 psi gage or absolute pressure For many industrial gases and liquids 00, 0545, 05, 6 or 40 ma output Field interchangeable EMC according to EN 66-8 MEDIA COMPATIBILITY

More information

Pressure Sensor/ PSE57 /PSE300AC Series. 3-Screen Display Sensor Monitor 500 VAC. Remote Type. Change the settings while checking the measured value.

Pressure Sensor/ PSE57 /PSE300AC Series. 3-Screen Display Sensor Monitor 500 VAC. Remote Type. Change the settings while checking the measured value. Remote Type Pressure Sensor/ 3-Screen Display Sensor Monir RoHS IP65 Pressure Sensor for General Fluids PSE57 Series Rated pressure range 0 1 MPa 0 2 MPa 100 100 kpa 0 5 MPa 0 500 kpa 0 10 MPa Withstand

More information

Compact Manometer. Pressure measurements can easily be taken any time, anywhere. POWER LIGHT

Compact Manometer. Pressure measurements can easily be taken any time, anywhere. POWER LIGHT Compact Manometer Series PPA Pressure measurements can easily be taken any time, anywhere. G GS PPA Compact and lightweight Portable type with a lightweight of only about 100 g (unit 50 g, battery 50 g)

More information

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm) Pressure Sensor (Stainless Steel Diaphragm) CSM DS_E_3_1 Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications Incorporates double diaphragms consisting of SUS316L stainless

More information

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cart., Size 2 4 Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 5 bar Direct acting, electrically operated 1 Description inverse proportional pressure-relief valves are direct acting screw-in cartridges

More information

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order Process Pump /5 Series Automatically Operated Type (Internal Switching Type)/Air Operated Type (External Switching Type) High abrasion resistance and low particle generation o sliding parts in wetted areas.

More information

Precision Regulator. IR1000/2000/3000 Series ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV IC ITVH ITVX PVQ VY1 AP100.

Precision Regulator. IR1000/2000/3000 Series ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV IC ITVH ITVX PVQ VY1 AP100. Precision Regulator //3 Series Basic Type Air Operated Type Series Model Set pressure range Port size Page Series Series 3 Series 3 3 3 Series 3 Series 3.5 to MPa. to MPa. to.8 MPa /8 8.5 to MPa. to MPa.

More information

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications Outstanding performance in extremely low pressure and low pressure ranges from 0.003 to. Realizing high performance, energy saving, and compact size. Realize precise pressure control in a pressure range

More information

Pressure Sensor PSE54#

Pressure Sensor PSE54# PRODUCT NAME Pressure Sensor MODEL / Series / Product Number PSE54# Table of Contents Safety Instructions 2 Model Identification and how to order 8 Definition and terminology 8 Mounting and Installation

More information

Pressure Sensor PSE53#

Pressure Sensor PSE53# PRODUCT NAME Pressure Sensor MODEL / Series / Product Number PSE53# Table of Contents Safety Instructions 2 Model Identification and how to order 8 Definition and terminology 8 Mounting and Installation

More information

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9 Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Fluid Proof pressure Operating pressure differential range (Difference between tank pressure and line pressure) Vibration resistance

More information

Hand lever valves VHER

Hand lever valves VHER Hand lever valves VHER Hand lever valves VHER Key features Powerful Flexible Practical -M- Flow 170 3800 l/min 4/3-way valve mid-position closed mid-position exhausted mid-position pressurised Connections:

More information

Process Pump. Series PAF3000/Series PAF5000

Process Pump. Series PAF3000/Series PAF5000 Process Pump Series 3/Series The excellent corrosion resistance is achieved due to the new PFA wetted material construction! PPS/PFA dual construction, withstand pressure and heat cycle performance have

More information

One-touch Fittings Manifold. Porting. One-touch fitting. One-touch fitting. One-touch fitting. One-touch fitting. One-touch fitting.

One-touch Fittings Manifold. Porting. One-touch fitting. One-touch fitting. One-touch fitting. One-touch fitting. One-touch fitting. One-touch Fittings Manifold Series KM RoHS Compact piping possible. Manifold piping possible. Many varieties (0 types) are available. s give the most efficient operation. KM1 KM1 orting Rc female thread

More information

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A Air Consumption 70% Down New Product Precision Regulator Air Saving Type RPE Series PRECISION REGULATOR RPE SERIES Large Air Saving CC-1072A Air Consumption 70% Down. New Type Eco-friendly Precision Regulator

More information

AMS 2710 PCB pressure sensor module with V output

AMS 2710 PCB pressure sensor module with V output FEATURES Universal pressure sensor module with 0.. 10 V voltage output Fully calibrated and temperature compensated sensor module Variants for (bidirectional) differential, gage, absolute and barometric

More information

How to Order. Body size. Pressure: 2 MPa. Pressure increase ratio 0 Twice. Symbol. Thread type. Body size

How to Order. Body size. Pressure: 2 MPa. Pressure increase ratio 0 Twice. Symbol. Thread type. Body size Booster Regulator Series VBA How to Order VBA 0 series VBA 0 0 Body size /4 Pressure: MPa Pressure increase ratio 0 Twice Thread type Symbol F Thread type G Port size Symbol Port size 0 /4 Symbol VBA0-0

More information

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08 Prop. -Way Pressure-Reducing Cart., Size / SAE 8 Q max = 1 l/min (4 gpm), p max = bar (6 psi) Direct acting, electrically operated 1 Description proportional -way pressure-reducing cartridges are size

More information

EXH. Specifications. Descriptions. Min. working pressure MPa

EXH. Specifications. Descriptions. Min. working pressure MPa Functional explanation Primary pressure flowed from passes through check valve on side, and flows in chamber A and B. Primary pressure also passes through pressure adjustment section and switching valve,

More information

Compact Regulator. ARX20 Series. 2.0 MPa compatible, piston type compact regulator ARJ

Compact Regulator. ARX20 Series. 2.0 MPa compatible, piston type compact regulator ARJ Compact Regulator 2 Series 2. MPa compatible, piston type compact regulator V SR X AP1 Compatible with inlet supply pressure of 2. MPa Employs a knob shape for easy operation Compact type (face to face

More information

Pneumatic valve islands

Pneumatic valve islands Pneumatic valve islands The MEGA solenoid air operated spool valve JOUCOMATIC offers a concept of solenoid air operated spool valves which can be fitted together to form islands. Due to its new patented

More information

Proportional Throttle Cartridges, Size 16

Proportional Throttle Cartridges, Size 16 Proportional Throttle Cartridges, Size 16 Q max = 5 l/min, p max = 5 bar, Q N max = 14 l/min at p 1 bar Two-Stage, with Seat-Valve Shut-Off 1 Description Normally closed Seat-valve shut-off from 1 Compact

More information

3-Way Safety Block DSV

3-Way Safety Block DSV 3-Way Safety Block DSV DSV 10 - M DSV 10 - M - T-ball DSV 10 - EY 1. Description 1.1. GENERAL The 3-way safety block is used to shut off and discharge hydraulic accumulators or consumers. It complies with

More information

Pressure Relief 3 Port Valve New. Sonic Conductance 45% With the indicator window Step1. With locking holes

Pressure Relief 3 Port Valve New. Sonic Conductance 45% With the indicator window Step1. With locking holes Conforming to OSHA Standard Pressure Relief Port Valve New RoHS with Locking Holes Weight Max. 60% Lighter Sonic Conductance 5% C[dm/s bar] VHS0 Max. Energy Saving Up Safety Measure Zero blow-by of the

More information

MANUAL KPS Pressure Control Valve

MANUAL KPS Pressure Control Valve TetraTec Instruments GmbH Gewerbestrasse 8 71144 Steinenbronn Deutschland E-Mail: info@tetratec.de Tel.: 07157/5387-0 Fax: 07157/5387-10 MANUAL Pressure Control Valve *** VERSION 1.0 *** Update: 17.11.2006

More information

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor INDUSTRIAL INSTRUMENTS AND CONTROLS SPECIALIST Kent-Taylor 2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters Features Include Base accuracy : ±0.075% Span limits

More information

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Installation, operating and maintenance Instructions for Seemag bypass level indicator Issue: S Date: 05-09-14 Type G35 General information The Seetru bypass magnetic level indicator, abbreviate SEEMAG, serves to show the filling level of fluids in tanks, basins, tubes etc. The Seemag operates

More information

SSL. Smart Valve Positioner.

SSL. Smart Valve Positioner. Smart Valve Positioner Smartest valve control device meeting a dynamic performance and a precise setting with a piezoelectric technology and an optimized auto-calibration program Features Auto-Calibration

More information

Electrically Operated Pressure-Relief Cartridge, Size 10

Electrically Operated Pressure-Relief Cartridge, Size 10 Electrically Operated Pressure-Relief Cartridge, Size 1 Q max = 14 l/min (37 gpm), p max = bar (5 psi) seated pilot stage, spool-type design, with remote contral port Z Series WUVPOC-2, WUVPLC-2 1 Description

More information

AMG. Model Note) Rated flow (l/min (ANR)) Port size Mass (kg) 1 8, , 3 8. Specifications Fluid. Element life

AMG. Model Note) Rated flow (l/min (ANR)) Port size Mass (kg) 1 8, , 3 8. Specifications Fluid. Element life Water Separator Series AMG Can remove water droplets in compressed air. Use this product in cases where water must be avoided, but not so dry as when an air dryer is used. Through the adoption of an element

More information

Proportional pressure regulators VPPM

Proportional pressure regulators VPPM Key features LED indicators Control elements Display Plug socket with cable Venting at both ends Manifold block Sub-base valve Assembly repositionable by 180 In-line valve H-rail mounting Compressed air

More information

Low torque Metal seal type Rotary joint

Low torque Metal seal type Rotary joint CAT.E0- A Low torque Metal seal type Rotary joint Long Life 0. to billion rotations Under SMC s life test conditions. Flexible Coupling Fixed (Body) Low rotational torque 0.00 to 0.0 N.m or less Rotary

More information

Pneumatic spool valve islands

Pneumatic spool valve islands Pneumatic spool valve islands P7.GB.R MEGA SPOOL VALVE ISLANDS MEGA pneumatic spool valve islands offer maximum performance along with flexibility, easy installation and simple operation. Due to their

More information

Air Saver Unit An environmentally friendly solution to reducing air consumption. Catalog 0698P

Air Saver Unit An environmentally friendly solution to reducing air consumption. Catalog 0698P An environmentally friendly solution to reducing air consumption. Catalog 0698P Contents Page Features... 3-4 Specifications... 5 Dimensions - ASV-200-AA-M5... 6 Dimensions - ASV-2000-AA... 7 Dimensions

More information

Port size. Model Screw-in ZFA10 1/8 ZFA20 1/4 ZFB10 ZFB20 ZFB30 ZFB40 ZFC5 ZFC7

Port size. Model Screw-in ZFA10 1/8 ZFA20 1/4 ZFB10 ZFB20 ZFB30 ZFB40 ZFC5 ZFC7 Air Suction Filter Series ZF Prevent from occurring vacuum equipment trouble due to solid foreign objects. Series Features Port size Model Screw-in for One-touch fittings Air flow Note) [L/min(ANR)] Filtration

More information

Series VBA1110 to 4200

Series VBA1110 to 4200 Booster Regulator Series 0 to 4200 Specifications increase ratio Max. supply pressure Set pressure range Ambient and fluid temperature Lubrication Installation adjustable mechanism 0-02 400-04 Handle operated

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation 2/2- and 3/2-way cartridge solenoid valve 2/2- und 3/2-Wege-Cartridge-Magnetventil Électrovanne cartridge à 2/2 ou 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation We reserve the

More information

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K Modular Type Regulator Series R Regulator Series R Model R M5 x.8 ccessory R2 /8, /4 R /4, 3/8 R3 /4, 3/8 R4 /4, 3/8, /2 Pages 36 through 4 Regulator with back flow mechanism Series RK R4-6 R5 R6 R2K RK,

More information

Intrinsically safe solenoid valves on/off controls - ATEX certification

Intrinsically safe solenoid valves on/off controls - ATEX certification www.atos.com Table E130-17/E Intrinsically safe solenoid valves on/off controls - ATEX certification valve body valve spool intrinsically safe solenoid electrical connector manual override DHW-0611/WP/6

More information

Technical Data Sheet TI-F50 Locking Units series KFH

Technical Data Sheet TI-F50 Locking Units series KFH English translation of German original Locking Units series KF Further important practical advice is given in Operating Manual BA-F50., Rod diameter 18 mm 50 mm øz 8 L 2 6 x 6 0 min. 4x30 KF 18 to KF 32,

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens AG 07 Overview Function U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/ Equipotential bonding Diaphragm The pressure

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens A 207 Overview Application The SITRANS P Compact pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials

More information

Technical Data. Dimensions

Technical Data. Dimensions 00 Model Number Features mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,

More information

IRV Series. Vacuum Regulator. New RoHS. New and Improved. Series IRV10/20

IRV Series. Vacuum Regulator. New RoHS. New and Improved. Series IRV10/20 Vacuum egulator New oh ingle ided Connections eries For ease of installation and panel mounting ingle sided connections Integrated digital pressure switch for panel mounting (Made to Order) Digital pressure

More information

MULTIPOL - VDMA. PNEUMATIC SPOOL VALVE ISLANDS VDMA ISO 02 - ISO 01 (G1/8 - G1/4) designed for connection to a PLC by multiwire cable

MULTIPOL - VDMA. PNEUMATIC SPOOL VALVE ISLANDS VDMA ISO 02 - ISO 01 (G1/8 - G1/4) designed for connection to a PLC by multiwire cable P8.G.R PEUATIC SPOOL VALVE ISLADS VDA - ISO - ISO (G/8 - G/) designed for connection to a PLC by multiwire cable ULTIPOL - VDA IPUT IPUT OUTPUT OUTPUT OUTPUT IPUT IPUT ULTIPOL - VDA Pneumatic spool valve

More information

Electro-Pneumatic Valve Positioners

Electro-Pneumatic Valve Positioners o. SS2-HEP180-0100 OVERVIEW FM Explosionproof approval Electro-Pneumatic Valve Positioners Mounted on control valves, HEP Electro-Pneumatic Valve Positioners model HEP18/19/28/29 control valve positions

More information

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information Liquid Level EK-L CSM_EK-L_DS_E 3 Liquid Level That Is Unaffected by the Color of the or Liquid Mount to bypass pipes. Fit a wide range of pipe diameters: 8 to mm or to mm Built-in Amplifiers to save space.

More information

Nugget 120 V14 Series

Nugget 120 V14 Series Nugget 0 V Series /2 & /3 Valves Solenoid and Pilot Operated G 1 4 High flow compact valves Sub-base and low profile manifolds Light weight, long life corrosion resistant materials Multipole and Fieldbus

More information

The Ins and Outs of I/P Transducers

The Ins and Outs of I/P Transducers The Ins and Outs of I/P Transducers By Mark B. Levine, ControlAir Inc. General description I/P transducers are versatile instruments that use an electrical control signal to proportionally regulate gas

More information

Inductive Linear Displacement Transducers Model IW 260 Measuring strokes: 80 mm, 170 mm, 240 mm, 360 mm

Inductive Linear Displacement Transducers Model IW 260 Measuring strokes: 80 mm, 170 mm, 240 mm, 360 mm Inductive Linear Displacement Transducers Model IW 260 Measuring strokes 80, 170, 240, 360 Document no. IW 100 HE Date 1.07.201 Contactless, robust sensor system Infinite resolution, no hysteresis Calibrated

More information

GM-7000 Series CE Approved Gas Control Valve

GM-7000 Series CE Approved Gas Control Valve Installation Instructions GM-7000 Issue Date November 9, 2012 GM-7000 Series CE Approved Gas Control Valve Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 2 mm flush Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 2 mm Installation flush Output

More information

Valve Proving System VDK 200 A S02

Valve Proving System VDK 200 A S02 Valve Proving System VDK 200 A S02 Valve proving system with the following approvals. UL Recognized File # MH17004 CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter

More information

Transmitter CS 21 Operation Manual

Transmitter CS 21 Operation Manual Transmitter CS 21 Operation Manual Content Page For your Safety 3 General Description 3 Detection Principle 4 Operational Notes 4 Design 4 Mounting Position of CS21 5 Mounting 6 Installation of Electrical

More information

Zelio Relays RSL Slim Interface Plug-In Relays

Zelio Relays RSL Slim Interface Plug-In Relays Zelio Relays RSL Slim Interface Plug-In Relays Catalog 8501CT0901 2009 Class 8501 CONTENTS Description............................................. Page Introduction.................................................3

More information

Compressed Air Cleaning Filter Series

Compressed Air Cleaning Filter Series Compressed ir Cleaning Filter Series M /FF Series For Water Droplet, Solid/Oil Separation and Deodorization Modular connection, Space-saving design, Labor-saving in piping! Uses the same spacer as the

More information

Expert Hydrostatic Level Transmitters

Expert Hydrostatic Level Transmitters Expert Hydrostatic s General Features MJK Expert hydrostatic level transmitters are designed for level measurement by submerging the transmitter in open channels, drains and tanks. Expert hydrostatic level

More information

No.IL02-OM00011-A PRODUCT NAME LOCK UP VALVE. MODEL/ Series IL201 IL211

No.IL02-OM00011-A PRODUCT NAME LOCK UP VALVE. MODEL/ Series IL201 IL211 No.IL02-OM00011-A PRODUCT NAME LOCK UP VALVE MODEL/ Series IL201 IL211 Table of Contents Instructions for your Safety 1~2 1. Summary 3 2. Specification 3 3. Operation Principle 3~4 4. Transportation and

More information

Contents. Operating instructions. Pressure switch, heavy-duty version Model PSM-520

Contents. Operating instructions. Pressure switch, heavy-duty version Model PSM-520 Operating instructions Contents EN Pressure switch, heavy-duty version Model PSM-520 1. General information 2. Design and function 3. Safety 4. Transport, packaging and storage 5. Commissioning, operation

More information

Valves, manually operated

Valves, manually operated Valves, manually operated Valves, manually operated Key features VHEM-P K/O-3-PK-3 H-3-¼-B KH/O-3-PK3 TH/O-3-PK3 VHEM-L F-3-¼-B Innovative Versatile Reliable Easy to mount Small and compact for a wide

More information

How to Order RM0 0 Z. IN/OUT fitting type Metric size Inch size Straight Elbow Straight Elbow Straight Elbow Straight Elbow ø ø ø ø ø ø ø ø ø/ ø/ ø/ ø

How to Order RM0 0 Z. IN/OUT fitting type Metric size Inch size Straight Elbow Straight Elbow Straight Elbow Straight Elbow ø ø ø ø ø ø ø ø ø/ ø/ ø/ ø Series RM/ End lock RME Port Plug End block End block type Mounting position L Left side R Right side L side end block 0. L VVQ0000 Single unit regulator / Port plug for regulator block ø0 0 Options Note

More information

GasSense NDIR User Manual

GasSense NDIR User Manual INDEX INDEX... 1 1. OVERVIEW... 2 2. TECHNICAL DATA... 3 3. SPECIFICATIONS... 4 4. PRODUCT DESCRIPTION... 5 4.1 Mechanical details... 5 4.2 Piping... 7 4.3 Connections... 7 5. INSTALLATION... 10 6. CALIBRATION

More information

Precision pressure regulators LRP/LRPS

Precision pressure regulators LRP/LRPS Precision pressure regulators LRP/LRPS q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement

More information

Related products. Components for air preparation and pressure adjustment / F.R.L. unit. Pressure gauge. Indidcator

Related products. Components for air preparation and pressure adjustment / F.R.L. unit. Pressure gauge. Indidcator Related products Pressure gauge / indicator omponents preparation and pressure adjustment / unit Refrigerating ir uto. drain ir Pressure gauge ONTENTS Pressure gauge assembly (G401-W) 660 With safety mark

More information

MASS-STREAM TM Instruction Manual. D-6200 Analog Mass Flow Meters / Controllers

MASS-STREAM TM Instruction Manual. D-6200 Analog Mass Flow Meters / Controllers MASS-STREAM TM Instruction Manual D-6200 Analog Mass Flow Meters / Controllers Doc. No.: 9.17.112A Date: 17-03-2017 ATTENTION Before installing and operating the instrument it is strongly recommended that

More information

Prewired position switches FA series

Prewired position switches FA series 2 Prewired position switches FA series Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 51 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable lever 41 45

More information

Angle Seat Valve / Air Operated Type

Angle Seat Valve / Air Operated Type Angle Seat Valve / Air Operated Type RoHS Steam Can be used with air or water Low pressure loss due to angle seat structure! Reduced leakage with rubber seal! Long service life 3 5 1 million cycles (Steam)

More information

TURQUOISE SWITCHES ABJ (BJ) SWITCHES

TURQUOISE SWITCHES ABJ (BJ) SWITCHES Ultra-miniature Size Sealed Switches TURQUOISE SWITCHES ABJ (BJ) SWITCHES Terminal type Mounting hole 2.3 mm type FEATURES Ultra-miniature size, High sealing performance sealed switches Elastomer double

More information

Digital relief valves D-CG

Digital relief valves D-CG Digital relief valves D-G unctional Symbols D-G- Specifications Size Maximum working pressure Rated flow Maximum flow Maximum adjustable pressure Ma Minimum control pressure Hysteresis Repeatability emperature

More information

Operating Instructions for Direct Flow Mass Flow Meter for gases. Model: DMW

Operating Instructions for Direct Flow Mass Flow Meter for gases. Model: DMW Operating Instructions for Direct Flow Mass Flow Meter for gases Model: DMW 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating Principle... 4 5.1.

More information

MODULES. Maximum Flow U.S.GPM. Max. Operating Pressure MPa (PSI) L/min. 005 Series 25 (3630) Modular Valves. 01 Series 31.

MODULES. Maximum Flow U.S.GPM. Max. Operating Pressure MPa (PSI) L/min. 005 Series 25 (3630) Modular Valves. 01 Series 31. F MODULES YUKEN's Modular Valves are stack type valves, and require no piping. hey not only rationalise system build, but they also meet the technical requirements for a variety of hydraulic systems. Stacking

More information

Specifications. Construction. 2 port valve/series VHK2 3 port valve/series VHK3. Component Parts. Standard style. Flame resistant style

Specifications. Construction. 2 port valve/series VHK2 3 port valve/series VHK3. Component Parts. Standard style. Flame resistant style Finger Valve SeriesVHK Large effective area: to mm 2 Small knob operating force: 0.43 to 1.4 kgfcm Poppet valve construction with few seal defects The series begins with the min. tube O.D. of. Selection

More information

2/2-way proportional valve

2/2-way proportional valve 2/2-way proportional valve General purpose 0... 12 bar DN 0.8... 2.0 mm 1/8 or sub-base version Type 2824 can be combined with Type 805 Digital control electronics DIN-rail version Type 07 Cable plug Typ

More information

Digital directional & flow control valves D-DF(R)G

Digital directional & flow control valves D-DF(R)G Digital directional & flow control valves D-DF(R)G Functional Symbols Model Code D-DFG- D-DFG-~ D-DFRG-/ D-DFG--C--- Digital directional & flow control valve Size Spool type (neutral position) : ll ports

More information

Technical Data Sheet MF010-O-LC

Technical Data Sheet MF010-O-LC Technical Data Sheet MF010-O-LC - 1 - 1. Properties The oxygen measuring system MF010-O-LC determines the oxygen content in gas mixtures up to a temperature of 250 C. It is particularly suitable for the

More information

IWAKI AMERICA FA-40VEW AIR DRIVEN BELLOWS PUMP INSTRUCTION MANUAL

IWAKI AMERICA FA-40VEW AIR DRIVEN BELLOWS PUMP INSTRUCTION MANUAL IWAKI AMERICA FA-40VEW AIR DRIVEN BELLOWS PUMP INSTRUCTION MANUAL CONTENTS 1 INTRODUCTION... 3 2 UNPACKING AND INSPECTION... 2 2.1 Operation Sequence... 3 2 IDENTIFICATION CODES... 4 3 SPECIFICATIONS...

More information

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH THIS MANUAL IS INTENDED FOR TECHNICAL STAFF IN CHARGE OF THE INSTALLATION, THE OPERATION AND THE MAINTENANCE OF THIS PRODUCT CAUTION!

More information

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications. Rated operating distance s n 5 mm 0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching

More information

Nugget 120 V14 Series

Nugget 120 V14 Series Nugget 0 V Series /2 & /3 Valves Solenoid and Pilot Operated G 1 4 High flow compact valves Sub-base and low profile manifolds Light weight, long life corrosion resistant materials Multipole and Fieldbus

More information

Pressure Sensor/ PSE57 /PSE300AC Series. 3-Screen Display Sensor Monitor 500 V AC. Remote Type. Change the settings while checking the measured value.

Pressure Sensor/ PSE57 /PSE300AC Series. 3-Screen Display Sensor Monitor 500 V AC. Remote Type. Change the settings while checking the measured value. Remote Type Pressure Sensor/ 3-Screen Display Sensor Monitor RoHS IP65 Pressure Sensor for General Fluids PSE57 Series Rated pressure range 0 to 1 MPa 0 to 2 MPa -100 to 100 kpa 0 to 5 MPa 0 to 500 kpa

More information

NTF-515. Operation Manual

NTF-515. Operation Manual NTF-515 Operation Manual RTI Technologies, Inc. 10 Innovation Drive York, Pennsylvania 17402 USA Phone: 717-840-0678 Toll Free: 800-468-2321 Web-site: www.rtitech.com Manual P/N: 035-81474-00 (RevA) TABLE

More information

L3 Pressure and Level transmitter

L3 Pressure and Level transmitter SENSORS FOR AND BIOPHARMA. Product Information L3 L3 Pressure and Level transmitter Range of applications Hydrostatic Level measurement in dynamic temperature environments Pressure measurement in pipes

More information

005 Series Modular Valves

005 Series Modular Valves 5 Series Modular Valves ype of Modular Valve Class Graphic Symbols age Solenoid Operated Directional Valve DSG-5- *** - * - ressure Control Valves Flow Control Valves Directional Control Valves Modular

More information

JUMO MAERA. Level probes Types , , , Installation Instructions T94Z001K000 V4.00/EN/

JUMO MAERA. Level probes Types , , , Installation Instructions T94Z001K000 V4.00/EN/ JUMO MAERA Level probes Types 401015, 402090, 404391, 404392 Installation Instructions 40101500T94Z001K000 V4.00/EN/00588054 Contents Contents 1 Safety information...............................................

More information

Position switches FP series

Position switches FP series A Position switches FP series Selection diagram 0 08 8 9 0 0 0 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fiber glass rod gasket sphere sphere adjustable lever safety adjustable lever

More information

Directional Controls

Directional Controls Vickers Directional Controls Directional Control Valves DG3V-3-*-60 Hydraulic Operated DG17V-3-*-60 Lever Operated DG18V-3-*-60 Air Operated DG20V-3-*-60 Cam Operated DG21V-3-*-60 Plunger Operated CETOP

More information

Relative pressure switch type 521

Relative pressure switch type 521 Relative pressure switch type 521 Pressure range 0... 2.5 600 bar The compact type 521 pressure switch is based upon the Huba Control developed thick film technology where the pressure measuring cell is

More information

LMU100/200 Series. Standard Specifications

LMU100/200 Series. Standard Specifications Mist Spray Unit MU/ Series Intermittent spray to cutting and press gear chains, etc. Standard Specifications Inlet air Oil tank set range Oil Dynamic viscosity of oil ( C) Oil tank capacity (cm ) mbient

More information

Axial piston pumps type PVC

Axial piston pumps type PVC www.atos.com Table TA16SK-1/E Axial piston pumps type PV variable displacement, by a full line of mechanical controls PV are variable displacement axial piston pumps for medium pressure operation, low

More information

GM Series Dual-Block Multi-Function Gas Control Valves

GM Series Dual-Block Multi-Function Gas Control Valves Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin GM Issue Date 0297 GM Series Dual-Block Multi-Function Gas Control Valves Figure 1: GM Series

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 00 Model Number Features 5 mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,

More information

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm 0102 Model Number Features 1.5 mm flush Accessories BF 8 Mounting flange, 8 mm Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 1.5 mm Installation flush

More information

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies We reserve the right to make technical changes without notice. Technische Änderungen vorbehalten. Sous réserve de modifications techniques.

More information