Multistage Ejector Series ZL
|
|
- Charles Montgomery
- 6 years ago
- Views:
Transcription
1 Multistage Ejector Series. Energy-saving, large flow rate, 3 stage diffuser construction Suction flow rate increased 5% and air consumption reduced % with 3 stage diffuser construction (ersus ø.3, one stage model) acuum pressure sensor With adaptor for vacuum acuum pressure stage performance Series Q Q Q3 Q Q Q3 stage performance 5% suction flow rate increase 3 stage performance Suction flow rate Diffusers stacked and integrated Compact size and large flow rate (Twice the flow rate of the ) With vacuum pressure gauge Digital vacuum pressure switch Rated pressure range:. to. ka 3-step setting 3 S ZSE3A Release valve Supply valve Release flow rate adjusting needle Suction flow rate (l/min (ANR)) With One-touch fittings Makes piping work easy ( only) Air consumption (l/min (ANR)) 63 6 Built-in silencer ort exhaust A Z S AM AE HE ush Adjust to set-value with buttons. ush Finish setting ower-saving function ower consumption is reduced by turning off the monitor. (Reduce power consumption by up to %.) For series ZSE3A, refer to the separate catalog (CAT.ES-7) for details. Series ariations Series Maximum suction flow rate (l/min (ANR)) Air consumption (l/min (ANR)) Built-in silencer ort exhaust With digital vacuum pressure switch With supply and release valves With supply valve ZSE3A acuum pressure sensor option acuum pressure gauge acuum adapter
2 Multistage Ejector Series How to Order Without valve K 5 M Z Nozzle diameter. mm Exhaust type Built-in silencer ort exhaust (EXH) thread type (ort exhaust only) Note 3) The thread ridge shape is conforming to G thread standard (JIS B3), but other shapes are not conforming to ISO63 and ISO79. F N T Rc/ G/ (3) /-4 NT /-4 NTF Supply valve/release valve combination K K With supply and release valves With supply valve Lead wire specifications (Applicable only when the vacuum pressure sensor specification is D for digital pressure switch for vacuum) L Lead wire with connector (Length m) Unit specifications (Applicable only when the vacuum pressure sensor specification is D for digital pressure switch for vacuum) M With unit switching function SI unit only With unit switching function (Initial value psi) Note ) W/ unit switching function is not permitted to sell for the domestic use in Japan, because the new Weight and Measure Act has been implemented since October, 99. Note ) Fixed unit: ka Rated voltage DC specifications S 5 R 3 AC specifications (5/6 Hz) 3 4 [5] [3] G H L LN LO M MN MO Grommet L plug connector M plug connector Electrical entry S Z U Lead wire length.3 m Lead wire length.6 m Lead wire length.3 m Without lead wires Without connector Lead wire length.3 m Without lead wires Without connector Light/Surge voltage suppressor Without light/surge voltage suppressor With surge voltage suppressor With light/surge voltage suppressor With light/surge voltage suppressor (Non-polar type) Type U is 4 or DC only. Since surge voltage is prevented by a rectifier in the case of AC, there is no type S. D Non-locking push type Locking slotted type Manual override Output specifications (Applicable only when the vacuum pressure sensor specification is D for digital pressure switch for vacuum) N A B C D E F acuum pressure sensor GN G D NN open collector output N open collector output NN open collector outputs N open collector outputs NN open collector output + Analog voltage output NN open collector output + Analog current output N open collector output + Analog voltage output N open collector output + Analog current output None acuum port adaptor Rc /8 acuum pressure gauge Digital pressure switch for vacuum 68
3 Multistage Ejector Series Standard With vacuum pressure gauge Adapter ort exhaust Ejector Specifications Model Nozzle diameter Maximum suction flow rate Air consumption Maximum vacuum pressure Maximum operating pressure Supply pressure range Standard supply pressure Operating temperature range Supply/Release alve Specifications art no. Type of valve actuation Fluid Operating pressure range Internal pilot type Ambient and fluid temperature Response time (For.5 Ma) () Maximum operating frequency Manual override ilot exhaust type Lubrication Mounting position Impact/ibration resistance () Enclosure Option Specifications. mm l/min (ANR) 63 l/min (ANR) 84 ka.7 Ma. to.5 Ma.4 Ma 5 to 5 C SYJ54- -S N.C. Air. to.5 Ma 5 to 5 C 5 ms or less 5 Hz Non-locking push type/locking slotted type ilot valve individual exhaust, Main valve/ilot valve common exhaust Not required Unrestricted 5/3 m/s Dust proof Note ) Based on JIS B dynamic performance test. (coil temperature C, at rated voltage, without surge voltage suppressor) Note ) Impact resistance: No malfunction when tested with a drop tester in the axial direction and at a right angle to the main valve and armature, one time each in both energized and deenergized states. (initial value) ibration resistance: No malfunction when tested with one sweep of 45 to Hz in the axial direction and at a right angle to the main valve and armature, one time each in both energized and deenergized states. (initial value) Note 3) Refer to Best neumatics No. for details on valves. acuum ressure Gauge Specifications art no. GZ3S Fluid Air ressure range to ka Scale range (Angular) 3 Accuracy ±3% F.S. (Full span) Class Class 3 Operating temperature range to 5 C Material Housing: olycarbonate/abs resin A Z S AM AE HE JIS Symbol Standard Mass (Basic) ort exhaust Digital pressure switch for vacuum (Excluding lead wire) Digital pressure switch for vacuum (Including 3 cores lead wire) Digital pressure switch for vacuum (Including 4 cores lead wire) alve (per pc.) 45 g + g +43 g +8 g +85 g +45 g 69
4 Series acuum ressure Switch Unit/Digital ressure Switch for acuum: ZSE3A-- - -X55 How to Order ZSE3A X55 Symbol N A B C D E F Output specifications Output Analog output Type oint oltage Current NN N NN N NN NN N N Option (Operating manual specifications) Y Operating manual (Leaflet) Without operating manual Option (Connector/Lead wire specifications) L Without lead wire Lead wire with connector (Length m) Display unit With unit display switching function M Fixed SI unit With unit display switching function (Initial value psi) Specifications Rated pressure range Set pressure range Withstand pressure Minimum unit setting Applicable fluid ower supply voltage Current consumption Switch output Maximum load current Maximum applied voltage Residual voltage Response time Short circuit protection Repeatability Hysteresis mode Window comparator mode Hysteresis Analog output Output voltage (Rated pressure range) Linearity Output impedance Output current (Rated pressure range) Linearity Load impedance. to. ka. to 5. ka 5 ka. ka Air, Non-corrosive gas, Non-flammable gas to 4 DC ±% (with power supply polarity protection) 4 ma (at no load) NN or N open collector output NN or N open collector outputs (selectable) 8 ma 8 (at NN output) or less (with load current of 8 ma).5 ms or less (with anti-chattering function:,, 5,, ms) Yes ±.% F.S. ± digit ariable ( to variable) to 5 ±.5% F.S. ±% F.S. or less Approx. kω 4 to ma ±.5% F.S. ±% F.S. or less Maximum load impedance: ower supply voltage : 3 Ω, ower supply voltage 4 : 6 Ω Minimum load impedance: 5 Ω Display 4-digit, 7-segment, -color LCD (Red/Green) Sampling cycle: 5 times/sec. Display accuracy ±% F.S. ± digit (Ambient temperature of 5 C) Indicator light Lights up when switch output is turned ON. (OUT: Green, OUT: Red) Enclosure I4 Operating temperature range Operating: to 5 C, Stored: to 6 C (No freezing or condensation) Operating humidity range Operating/Stored: 35 to 85% RH (No condensation) Withstand voltage AC for minute between live parts and case Insulation resistance 5 MΩ or more between live parts and case (at 5 DC Mega) to 5 Hz at whichever is smaller of.5 mm amplitude or ibration resistance m/s acceleration, in X, Y, Z directions, for hours each Impact resistance m/s, in X, Y, Z directions, for hours each Temperature characteristics ±% F.S. (Based on 5 C) Oilproof heavy-duty vinyl cable, 3 cores ø3.5, m Lead wire 4 cores Conductor area:.5 mm (AWG6) Insulator O.D.:. mm Standards CE Marking, UL/CSA, RoHS compliance Note ) When analog voltage output is selected, analog current output cannot be used together. Note ) When analog current output is selected, analog voltage output cannot be used together. Environment resistance Note ) oltage output Note ) Current output 7
5 Multistage Ejector Series Exhaust Characteristics/Flow Characteristics/Time to Reach acuum Exhaust Characteristics acuum pressure (ka) Flow Characteristics acuum pressure (ka) Time to Reach acuum acuum pressure in tank (ka) Supply pressure (Ma) Exhaust Characteristics acuum pressure acuum pressure Suction flow rate Air consumption Suction flow rate (l/min (ANR)) Air consumption (l/min (ANR)) Supply pressure:.4 Ma Suction flow rate (l/min(anr)) 3 Tank capacity: l Supply pressure:.4 Ma acuum pressure reached 89ka 8ka 66ka 53ka 4ka 6ka 3ka Time to reach vacuum (S) <How to Read the Graph> The graphics indicate the time required to reach a vacuum pressure determined by adsorption conditions for workpieces, etc., starting from atmospheric pressure in a l sealed tank. Approximately 8.8 seconds are necessary to attain a vacuum pressure of 89 ka. acuum pressure (ka) Flow Characteristics acuum pressure (ka) Time to Reach acuum acuum pressure in tank (ka) acuum pressure Supply pressure (Ma) Supply pressure:.4 Ma Suction flow rate (l/min(anr)) Q Qmax Suction flow rate Suction flow rate Air consumption Tank capacity: l Supply pressure:.4 Ma acuum pressure reached 89ka 8ka Time to reach vacuum (S) Suction flow rate (l/min (ANR)) Air consumption (l/min (ANR)) 66ka 53ka 4ka 6ka 3ka <How to Read the Graph> The flow characteristics indicate the relationship between the vacuum pressure and the suction flow rate of the ejector, and show that when the suction flow rate changes the vacuum pressure also changes. In general, this indicates the relationship at the ejector s standard operating pressure. In the graph, max indicates the maximum vacuum pressure, and Qmax indicates the maximum suction flow rate. These are the values that are published as specifications in catalogs, etc. Changes in vacuum pressure are explained below. max. If the ejector s suction port is closed and sealed tight, the suction flow rate becomes and the vacuum pressure increases to the maximum (max).. If the suction port is opened and air is allowed to flow (the air leaks), the suction flow rate increases and the vacuum pressure decreases. (the condition of and Q) 3. If the suction port is opened completely, the suction flow rate increases to the maximum (Qmax), while the vacuum pressure then drops almost to (atmospheric pressure). When adsorbing work pieces which are permeable or subject to leakage, etc., caution is required as the vacuum pressure will not be very high. A Z S AM AE HE 7
6 Series Construction Without valve Comonent arts Replacement arts No Description art no. Note No. Description Material art no. Suction cover 9 Sound absorbing material B F -S Front cover Without valve Sound absorbing material A F (Set no. for 9, & ) End cover Suction filter E Body acuum sensor unit Nozzle Diffuser Detent plug Other than vacuum switch Lead wire cover acuum switch specifications Front cover B alve plate Needle Supply valve (N.C.) SYJ54- -S Release valve (N.C.) SYJ54- -S 7
7 Multistage Ejector Series Dimensions: Series (Without valve) 5 7 x ø5.4 Label Standard Rc / 35 ort exhaust (/-4 NTF, G / /-4 NT) acuum pressure gauge x ø5.4 4 A With vacuum pressure gauge -G acuum adapter Rc /8 x ø5.4 7 With vacuum adapter -GN Z 6 S Digital pressure switch for vacuum x ø5.4 With digital pressure switch for vacuum S AM -D (9) AE HE Air pressure supply port () Applicable tubing O.D. 6 acuum port () Applicable tubing O.D. Section A x ø MULTISTAGE EJECTOR 59.5 Label Section A/ With Digital ressure Switch for acuum -D (ZSE3A) x M4 Thread depth 8 () (5.8)
8 + + + Series Dimensions: Series (With alve) With supply valve and release valve -K L -D Digital pressure switch for vacuum x ø5.4 Manual override 3.5 Release valve S Supply valve Manual override Release flow rate adjusting needle Air pressure supply () port Applicable tubing O.D. 6 acuum () port Applicable tubing O.D. x ø5.4 (9) (6.8) Label 8 9 Circuit diagram (3) (5.8) x M4 x.7 Thread depth 8 () With supply valve -K L -D Blanking plate assembly (SYJ5--3A) Digital pressure switch for vacuum S Supply valve Circuit diagram 74
9 Multistage Ejector Series Standard With vacuum pressure gauge With digital vacuum pressure switch With adaptor ort exhaust GN G D Nozzle diameter. mm Exhaust specifications Built-in silencer ort exhaust acuum pressure sensor Model Nozzle diameter Maximum suction flow rate Air consumption Maximum vacuum pressure Maximum operating pressure Supply pressure range Standard supply pressure Operating temperature range None acuum port adaptor Rc /8 acuum pressure gauge Digital pressure switch for vacuum Ejector Specifications How to Order Lead wire specifications (Applicable only when the vacuum pressure sensor specification is D for digital pressure switch for vacuum) L Lead wire with connector (Length m) Unit specifications (Applicable only when the vacuum pressure sensor specification is D for digital pressure switch for vacuum) M Note ) W/ unit switching function is not permitted to sell for the domestic use in Japan, because the new Weight and Measure Act has been implemented since October, 99. Note ) Fixed unit: ka N A B C D E F ø. mm x l/min (ANR) 6 l/min (ANR) 84 ka.7 Ma. to.5 Ma.4 Ma 5 to 5 C With unit switching function SI unit only With unit switching function (Initial value psi) Output specifications (Applicable only when the vacuum pressure sensor specification is D for digital pressure switch for vacuum) NN open collector output N open collector output NN open collector outputs N open collector outputs NN open collector output + Analog voltage output NN open collector output + Analog current output N open collector output + Analog voltage output N open collector output + Analog current output A Z S AM AE HE Made to Order (Refer to page 78 for details.) JIS Symbol Standard Mass ort exhaust Digital pressure switch for vacuum (Excluding lead wire) Digital pressure switch for vacuum (Including 3 cores lead wire) Digital pressure switch for vacuum (Including 4 cores lead wire) alve (per pc.) 7 g +3 g +43 g +8 g +85 g +45 g 75
10 Series Construction Component arts Replacement arts No. Description Note No. Description Material art no. Suction cover Front cover A 9 Sound absorbing material A Sound absorbing material F F -S (Set no. for 9 & ) 3 End plate 4 Body 5 acuum sensor unit 6 Nozzle 7 Diffuser 8 Detent plug Lead wire cover Other than vacuum switch acuum switch specifications 76
11 S Multistage Ejector Series Dimensions: Series Air pressure supply port () Rc /8 acuum port() Rc 3/4 76 Standard Label 6 ort exhaust A acuum pressure gauge (EXH.) Rc 5 With vacuum pressure gauge -G acuum adapter Rc /8 7 With vacuum adapter -GN Z S Digital pressure switch for vacuum With digital pressure switch for vacuum -D MULTISTAGE EJECTOR Section A (9) x ø4.4 AM AE HE (4) x M5 x.8 Thread depth 6 () Section A/ With Digital ressure Switch for acuum -D 3 (5.8) 77
12 + + S Series Made to Order Specifications lease contact SMC for detailed specifications, dimensions and delivery. With Supply and Release alves alve oltage Electrical entry acuum pressure switch Electrical entry X3 With supply and release valves type with supply and release valves Dimensions SMC
13 Series Specific roduct recautions Be sure to read before handling. Refer to front matters 38 and 39 for Safety Instructions and pages 844 to 846 for acuum recautions. Operation of Ejector alves Caution. When the air supply valve is turned ON, vacuum is generated by the flow of compressed air from the nozzle to the diffuser. When the vacuum release valve is turned ON, the vacuum is quickly released as air passes through the release flow adjustment needle and flows to the vacuum port. Caution Caution Operating Environment. Avoid use exposed to direct sunlight. Solenoid alves (Series ). For specific product precuations on solenoid valves, refer to the solenoid valve (Series SYJ5) catalog. A Z S AM AE HE 79
Multistage Ejector Series ZL
Multistage Ejector Series. Energy-saving, large flow rate, 3 stage diffuser construction Suction flow rate increased 5% and air consumption reduced % with 3 stage diffuser construction (ersus ø.3, one
More informationSeries ZL. Multistage Ejector. New models! ZL212 large flow rate type and ZL112 with valve. ZX ZR ZM ZY ZH ZU ZL ZF ZP ZCU
MULTISTAGE EJECTOR Multistage Ejector Series ZL ZX ZR ZM ZY ZH ZU ZL ZF Z ZCU acuum related New models! ZL212 large flow rate type and ZL112 with valve. 3.7-1 Multistage Ejector Series ZL112/212 Energy
More information10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor
2-Color Display High-Precision Digital Pressure Switch Series ZSEA(F)/EA ZSE E RoHS New IP65 ZSE E ZSE0 E0 M8 connector type E70 ZSE E E Applicable Air, Non-corrosive gas, Non-flammable gas fluid Can copy
More informationCompact Pressure Switch
Compact Pressure Switch Series ZSE1 (For Vacuum)/SE1 (For Positive Pressure) For General Pneumatics Can be integrated with ZM ejector system. RoS Variable hysteresis 1 to 10% of set pressure (Variable)
More informationCompact Pressure Switch
Compact Pressure Switch Series 2 (For Vacuum)/ 2 (For Positive Pressure) For General Pneumatics Can be integrated with ZX or ZR ejector system. A Easy and simple wiring Connector type 77 Compact Pressure
More informationDigital Flow Switch. Series PFM7
Compatible with rgon (r), Carbon Dioxide (CO) and the Mixed Gas (r+co) Digital Flow witch eries PFM7 Flow adjustment valve Fluid r, CO r + CO RoH -color display ee abnormal values at a glance. llows flow
More informationCAT.E813- B. Multistage Ejector. Series ZL. New Models! ZL212 large flow rate type and ZL112 with valve.
CAT.E813- B Multistage Ejector Series ZL New Models! ZL212 large flow rate type and ZL112 with valve. Multistage Ejector Series ZL112/212 Energy saving, large flow rate, 3 stage diffuser construction Suction
More informationSeries IRV1000/2000/3000
CAT.ES60-16 A Regulator Series /2000/3000 Allows adjustment of vacuum line pressure Regulator Series /2000/3000 3 sizes offered in the series Variations have been expanded to three sizes from only one
More informationSpace Saving Vacuum Ejector & Vacuum Pump System
CAT.ES0-1 B Space Saving acuum Ejector & acuum Pump System Conventional ZX 21. mm mm ZQ Series ZQ Width mm Weight 9 g Single unit with vacuum pressure switch and suction filter Ejector Pump System Digital
More informationPrecision Regulator. Series Model Regulating pressure range Port size Page
Precision Regulator Series // Basic Type Air Operated Type Series Model Regulating pressure range Page Series Series Series Series Series.5 to MPa. to MPa. to.8 MPa /8 55.5 to MPa. to MPa /4 55. to.8 MPa.
More informationDigital electro-pneumatic regulators Series ER100
CATALOGUE > Release 8.2 Digital electro-pneumatic regulators Series ER100 TREATMENT > Digital electro-pneumatic regulators Series ER100 Port G1/4» Compact design» Digital display» Analog and digital input»
More informationProportional pressure regulators VPPE
Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/
More informationComponents for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.
Components preparation and pressure adjustment ABP Overview ABP is a component that enables boosting by s only up to twice primary pressure (.0MPa max.) in combination with using air tank but not using
More information435 psi (3.0 MPa) Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. Maximum supply pressure. Set pressure range.
435 psi (3.0 MPa) Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator RoHS Maximum supply pressure Set pressure range Stability 435 psi (3.0 MPa) 29 to 290 psi (0.2 to 2.0 MPa) Stepless control
More information2/ Port G1/4
CATALOGUE > Release 8.8 > Series ER100 digital electro-pneumatic regulators Series ER100 digital electro-pneumatic regulators Port G1/4 Compact design Digital display Analog and digital input Programmable
More informationPilot Check Valve: Metal Body Type
INFORMATION Pilot Check Valve: Metal Body Type The use of a metal body improves strength and environmental resistance. Temporary intermediate stops are possible. *1 *1 Precise intermediate stops are not
More informationPSE Series. Remote Type Pressure Sensors/Pressure Sensor Controllers PSE550 ISE70 PS ISA3 ISA2 ISE35 PSE IS ISG ZSM1
Remote Type Pressure Sensors/Pressure Sensor Controllers PSE Series Compact Pneumatic Pressure Sensor PSE530 Pressure Sensor for General FluidsPSE560 sp.134 Low Differential Pressure Sensor sp.143 PSE550
More informationPressure Sensor/ PSE57 /PSE300AC Series CAT.ES A. 3-Screen Display Sensor Monitor. 500 VAC <Twice that of the PSE560> Remote Type
Remote Type Pressure Sensor/ 3-Screen Display Sensor Monir RoHS IP65 Pressure Sensor for General Fluids PSE57 Series Rated pressure range 0 1 MPa 0 2 MPa 100 100 kpa 0 5 MPa 0 500 kpa 0 10 MPa Withstand
More information1.0. ISE70/71 Series CAT.ES A. MPa/1.6 MPa. 3-Screen Display High-Precision Digital Pressure Switch. Angled display.
3-Screen Display High-Precision Digital Pressure Switch For Air 1.0 ISE70 ISE71 MPa/1.6 MPa RoHS IP67 It is possible to change the settings while checking the measured value. Main screen Measured value
More information5.0 MPa Maximum Supply Pressure. New. Stepless control of air pressure proportional to an electrical signal. Series ITVX CAT.
5.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator This product is only for blowing gas. This product does not have sufficient pressure control for other applications (driving, sealing,
More information2-Color Display Digital Flow Switch
2-Color Display Digital Flow Switch Series Flow rate range:, 25, 5, L/min. Minimum unit setting:. L/min. (. L/min when the flow rate range is 25, 5, L/min.) Fluid Repeatability: ±%F.S. ir, N2, r, CO2 Grease-free
More informationSelf-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type.
Process Pump Series 3/5 Automatically Operated Type (Internal Switching Type)/Air Operated Type (External Switching Type) High abrasion resistance and low particle generation o sliding parts in wetted
More informationBooster Regulator/Air Tank
Booster Regulator/Air Tank Increase factory air pressure by up to 4 times! Air-only operation requires no power supply, reduces heat generation, and Boost pressure allows easy installation. NEW Renewed
More informationKTE6000 / KTU6000 Series OEM pressure transmitters for industrial media
FEATURES 50 mbar to 400 bar, 5 to 6000 psi gage or absolute pressure For many industrial gases and liquids 00, 0545, 05, 6 or 40 ma output Field interchangeable EMC according to EN 66-8 MEDIA COMPATIBILITY
More informationPressure Sensor/ PSE57 /PSE300AC Series. 3-Screen Display Sensor Monitor 500 VAC. Remote Type. Change the settings while checking the measured value.
Remote Type Pressure Sensor/ 3-Screen Display Sensor Monir RoHS IP65 Pressure Sensor for General Fluids PSE57 Series Rated pressure range 0 1 MPa 0 2 MPa 100 100 kpa 0 5 MPa 0 500 kpa 0 10 MPa Withstand
More informationVacuum Regulator. IRV10/20 Series. Weight reduced by. RoHS ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV
Vacuum egulator IV0/ eries oh AJ A45 ingle ided Connections eries AX For ease of installation and panel mounting AM AM Integrated digital pressure switch for panel mounting I -A I (Made to Order) ingle
More informationSPCH/ Blowing block
> > for linear stretch blow moulding machines > > Compact and safe design > > Best suited for PET bottles up to litres, depending on cycle time Technical features Medium: Compressed air (purity class 3..3
More informationSeries 10-IRV10/20. Vacuum Regulator C08 IRV C08 IRV 20 A. How to Order. Standard connections. Single sided connections. Accessory w Nil G ZN ZP ZA ZB
Vacuum egulator eries -IV/ How to Order tandard connections IV C08 traight Clean series ody size Max. flow 140 L/min (N) Max. flow 240 L/min (N) L Fittings traight Connection tubing O.D. ymbol ubing O.D.
More informationData Sheet. Vacuum generators
Data Pack G Issued March 1997 1502323721 Data Sheet Vacuum generators Specifications Fluid Air perating pressure range 2.5~6kgf/cm 2 Max. operating pressure 7kgf/cm 2 perating temperature range 5~60 C
More informationE8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)
Pressure Sensor (Stainless Steel Diaphragm) CSM DS_E_3_1 Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications Incorporates double diaphragms consisting of SUS316L stainless
More informationSeries ZFC. Air Suction Filter In-line Type with One-touch Fittings
CAT.E832- A Air Suction Filter In-line Type with One-touch Fittings Series ZFC An in-line type air suction filter that prevents trouble in vacuum equipment due to contaminants in the air IN/OUT straight
More informationCompact Manometer. Pressure measurements can easily be taken any time, anywhere. POWER LIGHT
Compact Manometer Series PPA Pressure measurements can easily be taken any time, anywhere. G GS PPA Compact and lightweight Portable type with a lightweight of only about 100 g (unit 50 g, battery 50 g)
More informationProcess Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order
Process Pump /5 Series Automatically Operated Type (Internal Switching Type)/Air Operated Type (External Switching Type) High abrasion resistance and low particle generation o sliding parts in wetted areas.
More informationTechnical Specifications
No. : PS##-OMG0006 Technical Specifications PSE560 series Contents Safety.P2 Model Indication Method.P6 Specification.P7 Full View with Dimensions.P8 Installation.P9 Examples of Internal Circuit and Wiring.P10-1
More informationInverse Proportional Pressure-Relief Cart., Size 2 4
Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 5 bar Direct acting, electrically operated 1 Description inverse proportional pressure-relief valves are direct acting screw-in cartridges
More informationMaximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications
Outstanding performance in extremely low pressure and low pressure ranges from 0.003 to. Realizing high performance, energy saving, and compact size. Realize precise pressure control in a pressure range
More informationProportional Pressure-Relief Cartridge Valve, Size 2...4
Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min, p max = 3 bar Direct acting, electrically operated 1 Description proportional pressure-relief valves are direct acting screw-in cartridges
More informationFor Air Pressure. AP-30 Series. Digital Display & Digital Control. EASY-TO-SEE 2-color display. Two-color digital display pressure sensor
Cat No AP3-KA-C Two-color digital display pressure sensor AP-3 Series Digital Display & Digital Control For Air Pressure EASY-TO-SEE 2-color display Green and red two-color LED display clearly shows abnormal
More informationVACUUM REGULATORS CONTENTS
CAD drawing data catalog is available. ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Small Regulators Features 759 Specifications, Order Codes, Flow Rate
More informationHand lever valves VHER
Hand lever valves VHER Hand lever valves VHER Key features Powerful Flexible Practical -M- Flow 170 3800 l/min 4/3-way valve mid-position closed mid-position exhausted mid-position pressurised Connections:
More informationInverse Proportional Pressure-Relief Cart., Size 2 4
Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 35 bar Direct acting, electrically operated Description Compact construction for cavity type AL 3/-6 UNF Operated by a proportional
More informationHow to Order. Rc NPT 1/8 1/4 3/8 1/2
AWM 3 AWD 3 Mist Separator Regulator AWM2 to AWM4 Micro Mist Separator Regulator AWD2 to AWD4 3 E 3 E How to Order Mist Separator Regulator 1 2 Micro Mist Separator Regulator The AWM series is made up
More informationcompact ejector, Series ECM with Adjustable release pulse with silencer With filter vacuum switch: electronic 2 x PNP
00134428 Type Miniature compact injector Ambient temperature min./max. +0 C / +0 C Medium temperature min./max. +0 C / +0 C Working pressure min./max. 2. bar / 6 bar Medium Compressed air Max. particle
More informationProportional Pressure-Relief Cartridge Valve, Size 2...4
Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description proportional pressure-relief valves are direct acting
More informationProcess Pump. PAF3000 Series/PAF5000 Series
Process Pump PAF3 Series/PAF Series RoHS The excellent corrosion resistance is achieved due to the new PFA wetted material construction! PPS/PFA dual construction, withstand pressure and heat cycle performance
More informationSeries SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100
Clean Air Filter Variations SFD SFD SFD SFD Made to Order Type Disposable (non-replaceable element) Cartridge (replaceable element) Flow rate L/min (ANR) (at inlet pressure.7 MPa) Up to 6 Up to 8 Up to
More informationPressure Sensor PSE53#
PRODUCT NAME Pressure Sensor MODEL / Series / Product Number PSE53# Table of Contents Safety Instructions 2 Model Identification and how to order 8 Definition and terminology 8 Mounting and Installation
More information4/2 way Pneumatic Solenoid Valve
4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11
More informationInverse Proportional Pressure-Relief Cartridge, Size 10
Inverse Proportional Pressure-Relief Cartridge, Size 1 Q max = 12 l/min, p max = 3 bar Seated pilot, spool-type main stage, damped design 1 Description inverse-proportional pressure-relief valves are size
More informationInverse Prop. Pressure-Relief Cart., Size 2 4
Inverse Prop. Pressure-Relief Cart., Size Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description inverse proportional pressure-relief valves are direct acting screw-in
More informationDPS-400 SERIES DPH-100 SERIES
745 Dual Display Digital Pressure Sensor For Gas DPS-400 SERIES SERIES General terms and conditions... F- guide... P.699~ Related Information Glossary of terms... P.156~ General precautions... P.1566 PHOTO
More informationPrecision Regulator. IR1000/2000/3000 Series ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV IC ITVH ITVX PVQ VY1 AP100.
Precision Regulator //3 Series Basic Type Air Operated Type Series Model Set pressure range Port size Page Series Series 3 Series 3 3 3 Series 3 Series 3.5 to MPa. to MPa. to.8 MPa /8 8.5 to MPa. to MPa.
More informationEXH. Specifications. Descriptions. Min. working pressure MPa
Functional explanation Primary pressure flowed from passes through check valve on side, and flows in chamber A and B. Primary pressure also passes through pressure adjustment section and switching valve,
More informationProcess Pump. Self-priming makes priming unnecessary. Air operated type. Air supply port. 5 port solenoid valves. Application Example
Process Pump Series 3/5 Automatically Operated Type (Internal Switching Type)/Air Operated Type (External Switching Type) High abrasion resistance and low particle generation No sliding parts in wetted
More informationAuto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9
Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Fluid Proof pressure Operating pressure differential range (Difference between tank pressure and line pressure) Vibration resistance
More informationProcess Pump. Series PAF3000/Series PAF5000
Process Pump Series 3/Series The excellent corrosion resistance is achieved due to the new PFA wetted material construction! PPS/PFA dual construction, withstand pressure and heat cycle performance have
More informationVPPC02, VPPC08 3-way proportional pressure control valve, electronic closed loop control
VPPC, VPPC -ay proportional pressure control valve, > > Nominal diameter,, flange version G/ > > Visual function display (optional) > > Compact and lighteight design > > Field bus capable as part of a
More informationDirect Operated Precision Regulator Modular Style. Standard Specifications
1 Direct Operated Precision Regulator Modular Style Series P3 Courtesy of Steven Engineering, Inc.-23 Ryan Way, South San Francisco, CA 948-637-Main Office: (65) 588-92-Outside Local Area: (8) 258-92-www.stevenengineering.com
More informationPressure Sensor PSE54#
PRODUCT NAME Pressure Sensor MODEL / Series / Product Number PSE54# Table of Contents Safety Instructions 2 Model Identification and how to order 8 Definition and terminology 8 Mounting and Installation
More information2/2-Way Solenoid Control Valve
2/2-Way Solenoid Control Valve Excellent range (1:200) Very good response Compact valve design Orifice sizes 0.05... 2.0 mm ort connection 1/8 or sub-base Type 2871 can be combined with Type 8605 Digital
More informationPressure Sensor for General Fluids PSE56#
PRODUCT NAME Pressure Sensor for General Fluids MODEL / Series / Product Number PSE56# Table of Contents Safety Instructions 2 Model Identification and How to Order 8 Definition and terminology 8 Mounting
More informationPower Valve: Precision Regulator. High precision, large capacity relief regulator
Power Valve: Precision Regulator Series VEX High precision, large capacity relief regulator port large exhaust capacity pressure reducing valve which utilizes a nozzle flapper mechanism available as air
More informationALF400 to 900, ALT-5/-9
Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Auto feed lube 00 00-0 00 00 00 900 - --IS- -9 AIR : OIL : Fluid Proof pressure Air. MPa 0. MPa.0 MPa (Note ) Operating pressure differential
More informationProcess Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order. Option. Symbol.
Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) Series PAF3 Female threaded PAF31 3 3 Note 1) Actuation Actuation Automatically operated Note
More informationCompact Manometer. Pressure measurements can easily be taken any time, anywhere.
1 Compact Manometer Series PPA Pressure measurements can easily be taken any time, anywhere. Compact and lightweight Portable type with a lightweight of only about 100 g (unit 50 g, battery 50 g) can also
More informationTerminal block. D sub-connector
Spd Series variation ol method Solenoid valve EVD-1 EVD-3 EVR EV21V EVS2 EVL MEVT Model Electro pneumatic regulator Functions include pressure and error display and direct memory. The 1-bit parallel model
More informationNew Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A
Air Consumption 70% Down New Product Precision Regulator Air Saving Type RPE Series PRECISION REGULATOR RPE SERIES Large Air Saving CC-1072A Air Consumption 70% Down. New Type Eco-friendly Precision Regulator
More informationOne-touch Fittings Manifold. Porting. One-touch fitting. One-touch fitting. One-touch fitting. One-touch fitting. One-touch fitting.
One-touch Fittings Manifold Series KM RoHS Compact piping possible. Manifold piping possible. Many varieties (0 types) are available. s give the most efficient operation. KM1 KM1 orting Rc female thread
More informationHow to Order. Body size. Pressure: 2 MPa. Pressure increase ratio 0 Twice. Symbol. Thread type. Body size
Booster Regulator Series VBA How to Order VBA 0 series VBA 0 0 Body size /4 Pressure: MPa Pressure increase ratio 0 Twice Thread type Symbol F Thread type G Port size Symbol Port size 0 /4 Symbol VBA0-0
More informationTH-1800-T TRX-700-CNG Converter
TH-1800-T TRX-700-CNG Converter low detector The CNG fuel gas flowmeter is so accurate as to meet a demand of measuring the CNG directly by making the most use of our well-established mini-thermal flowmeter
More informationCompact Ejectors. Compact Ejectors SCPi / SMPi Suction rate from 75 l/min to 185 l/min
Compact Ejectors Suitability for Industry-Specific Applications Applications Handling of air-tight as well as porous workpieces supply and vacuum monitoring in automated systems For use in sheet metal
More informationRelated Products: Auto Drain Valve. Model/Specifications. Model
Related Products: Auto Drain Valve /600 Drainage is automatically discharged in a reliable manner, without requiring human operators. Highly resistant to dust and corrosion, operates reliably, and a bowl
More informationINSTALLATION & MAINTENANCE INSTRUCTIONS
DESCRIPTION / IDENTIFICATION The QBX series valve uses Proportion-Air closed loop technology for Pressure control. It gives an output pressure proportional to an electrical command signal input. The QB1X
More informationG1/8 G1/8. Model 0 bar -0,1 bar -0,2 bar -0,3 bar -0,4 bar -0,5 bar -0,6 bar -0,7 bar -0,8 bar
single stage pumps M/5811 Very high induced air capacity % lower air consumption than comparable single stage units No wearing parts Compatible with a wide range of line contaminants llows direct connection
More informationAMS 2710 PCB pressure sensor module with V output
FEATURES Universal pressure sensor module with 0.. 10 V voltage output Fully calibrated and temperature compensated sensor module Variants for (bidirectional) differential, gage, absolute and barometric
More informationPneumatic valve islands
Pneumatic valve islands The MEGA solenoid air operated spool valve JOUCOMATIC offers a concept of solenoid air operated spool valves which can be fitted together to form islands. Due to its new patented
More information3-Way Safety Block DSV
3-Way Safety Block DSV DSV 10 - M DSV 10 - M - T-ball DSV 10 - EY 1. Description 1.1. GENERAL The 3-way safety block is used to shut off and discharge hydraulic accumulators or consumers. It complies with
More informationProp. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08
Prop. -Way Pressure-Reducing Cart., Size / SAE 8 Q max = 1 l/min (4 gpm), p max = bar (6 psi) Direct acting, electrically operated 1 Description proportional -way pressure-reducing cartridges are size
More informationMANUAL KPS Pressure Control Valve
TetraTec Instruments GmbH Gewerbestrasse 8 71144 Steinenbronn Deutschland E-Mail: info@tetratec.de Tel.: 07157/5387-0 Fax: 07157/5387-10 MANUAL Pressure Control Valve *** VERSION 1.0 *** Update: 17.11.2006
More informationWARNING. Work drop prevention check valves FPV series. Vacuum accessories. Safety handling of workpiece with several pads
Work drop prevention check valves series Safety handling of workpiece with several pads Enable using one CONVUM ejector and several pads, in applications where some of the suction pads may not be in contact
More informationINSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant
INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION The QB3 is a closed loop pressure regulator consisting of two solenoid valves, internal pressure transducer, and electronic controls mounted to an integrated
More informationSSL. Smart Valve Positioner.
Smart Valve Positioner Smartest valve control device meeting a dynamic performance and a precise setting with a piezoelectric technology and an optimized auto-calibration program Features Auto-Calibration
More informationCompact Regulator. ARX20 Series. 2.0 MPa compatible, piston type compact regulator ARJ
Compact Regulator 2 Series 2. MPa compatible, piston type compact regulator V SR X AP1 Compatible with inlet supply pressure of 2. MPa Employs a knob shape for easy operation Compact type (face to face
More informationINSTRUMENT MANUAL VP50 PROPORTIONAL CONTROL VALVE
INSTRUMENT MANUAL VP50 PROPORTIONAL CONTROL VALVE Watson Smith Instrumentation IMPORTANT SAFETY WARNING CONTENTS Please read these instructions carefully BEFORE this instrument is installed or maintained.
More informationPressure Relief 3 Port Valve New. Sonic Conductance 45% With the indicator window Step1. With locking holes
Conforming to OSHA Standard Pressure Relief Port Valve New RoHS with Locking Holes Weight Max. 60% Lighter Sonic Conductance 5% C[dm/s bar] VHS0 Max. Energy Saving Up Safety Measure Zero blow-by of the
More informationProportional Throttle Cartridges, Size 16
Proportional Throttle Cartridges, Size 16 Q max = 5 l/min, p max = 5 bar, Q N max = 14 l/min at p 1 bar Two-Stage, with Seat-Valve Shut-Off 1 Description Normally closed Seat-valve shut-off from 1 Compact
More informationRegulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut
Regulator for 2 MPa RX 2 How to Order RX2 1 Regulator 1 Regulating pressure.5 to.85mpa {.51 to 8.7kgf/cm²}.5 to.3mpa {.51 to 3.1kgf/cm²} Thread type Nil N F Rc(PT) NPT (PF) Port size 1 2 ccessories/options
More informationIR1000-A IR1010-A IR1020-A
Document No. IR -OMT0020 PRODUCT NAME Precision Regulator MODEL / Series / Product Number IR1000-A IR1010-A IR1020-A Contents Safety Instructions 1 to 5 1. Application 6 2. Specifications 6 3. Construction
More informationOperation Manual Air Saver Unit ASV5000 Series
9IM-V066-b Operation Manual Air Saver Unit ASV5000 Series Thank you for your choice of Kuroda Pneumatics LTDs product on this time. Please read this operation manual carefully and use the product correctly.
More informationInstallation, operating and maintenance Instructions for Seemag bypass level indicator
Issue: S Date: 05-09-14 Type G35 General information The Seetru bypass magnetic level indicator, abbreviate SEEMAG, serves to show the filling level of fluids in tanks, basins, tubes etc. The Seemag operates
More informationPneumatic spool valve islands
Pneumatic spool valve islands P7.GB.R MEGA SPOOL VALVE ISLANDS MEGA pneumatic spool valve islands offer maximum performance along with flexibility, easy installation and simple operation. Due to their
More informationThe Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure
General-purpose Limit Switch CSM_DA-_N_DS_E The Limit Switch with Better Seal, Shock Resistance, and Strength A double seal on the head, a complete gasket cover, and other features ensure a better seal
More informationPneumatic pressure switch 20DD
Sensor system: stainless steel 0,2 to 6 bar Microswitch with gold plated contacts (suitable for intrinsically safe operation) High accuracy (max. scattering < 1,5%) Excellent sealing properties (better
More informationSSR. Smart Valve Positioner.
Smart Valve Positioner Smartest valve control device meeting a dynamic performance and a precise setting with a piezoelectric technology and an optimized auto-calibration program Features Auto-Calibration
More informationSimple Set. Pressure Independent Control Valves 2 Way 1/2-2
The Bray Simple Set is a threaded pressure independent control (PIC) valve designed for a wide variety of hot water and chilled water control applications. The SS Series combines high rangeability control
More informationV83 series Redundant valve manifold systems - Modular with bypass 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability
V8 series Redundant valve manifold systems - Modular with bypass oo Safety, oo Availability and oo Safety and Availability > > Modular design - Maxseal valves > > able terminations inside coil housing
More informationFunction. Valve Size. Pilot Oil. p min. Bold: Designates Tier I products and options.
Catalog HY14-255/US echnical Information ilot Operated ressure Reducing Valves Series VMY*6 General Series VMY*6 valves consist of the main stage with valve spools and the pilot stage with the proportional
More informationMod. M M M063..
CATALOGUE > Release 8.6 > Pressure gauges Pressure gauges Mod. M04.. - M05.. - M06.. Precision classes CL1,6 and CL2,5» Radial connection» Rear connection» Panel mounting To select the most suitable pressure
More informationElectric regulating valves Type CCMT 2 - CCMT 8 / CCMT 16 - CCMT 42
Data sheet Electric regulating valves Type CCMT 2 - CCMT 8 / CCMT 16 - CCMT 42 The CCMT is an electrically operated valve designed specifically for operation in CO 2 systems. The CCMT valve concept is
More information