SITRANS P measuring instruments for pressure

Size: px
Start display at page:

Download "SITRANS P measuring instruments for pressure"

Transcription

1 Siemens AG 007 SITRANS P measuring instruments for pressure / Product overview /4 Transmitters for gage and absolute pressure /4 Z series for gage and absolute pressure /9 ZD series for gage and absolute pressure /1 Transmitters for food, pharmaceuticals and biotechnology /1 SITRANS P Compact for gage and absolute pressure /19 Transmitters for gage and absolute pressure /19 SITRANS P300 /35 Transmitters for gage pressure for paper industry SITRANS P300 and DS III series with PMC connection /35 Technical description Technical specifications, ordering data, dimensional drawings /40 - DS III series with PMC connection /46 - SITRANS P300 with PMC connection /51 Transmitters for gage, absolute and differential pressure, flow and level DS III, DS III PA and DS III FF series /51 Technical description Technical specifications, ordering data, dimensional drawings /58 - for gage pressure /67 - for gage pressure with front-flush diaphragm /75 - for absolute pressure (gage construction) /84 - for absolute pressure (differential construction) /93 - for differential pressure and flow /109 - for level /119 SITRANS P Accessories /119 Supplementary electronics for 4-wire connection /11 Accessories/spare parts for SITRANS P P300 and DS III series /16 Factory-mounting of valve manifolds on SITRANS P transmitters /130 Transmitters for hydrostatic level /130 MPS series (submersible sensor) /133 Remote seals for transmitters and pressure gauges /133 Introduction /139 Pancake type diaphragm seal with flexible capillary tube /140 Flange-type diaphragm seal directly connected /143 Diaphragm seal flanged off-line low-pressure type, directly connected /144 Flange-type diaphragm seal with flexible capillary tube /146 Diaphragm seal flanged off-line type /148 Diaphragm seal flanged off-line low-pressure type /150 Flushing rings /15 Diaphragm seal with quick connection /155 Inline diaphragm seal with quick connection /157 Diaphragm seal threaded design /158 Diaphragm seal threaded, low-pressure design /160 Inline diaphragm seal, wafer for pressure /16 Diaphragm seal, saddle /164 Measuring setups /165 - with remote seals /167 - without remote seals /169 Questionnaire /171 Fittings /171 Technical description, Selection aid /17 Double shut-off valves /174 -, 3- and 5-spindle valve manifolds DN 5 /177 Oval flange You can download all instructions, catalogs and certificates for SITRANS P free of charge at the following Internet address: Siemens FI US Edition

2 Siemens AG 007 Product overview Overview Application Description Page Software for Parameterization SITRANS P measuring instruments for pressure, absolute pressure, differential pressure, flow and level Two-wire transmitters for measuring gage and absolute pressure SITRANS P, Z series Compact single-range transmitters Analog electronics, available ex stock /4 Two-wire transmitters for measuring gage and absolute pressure SITRANS P, ZD series 5:1 Turn down Digital display Charger /9 Transmitters for gage and absolute pressure for food, pharmaceuticals and biotechnology SITRANS P Compact Single-range transmitters in -wire system Sanitary design with various aseptic connections according to EHEDG, FDA and GMP recommendations. /1 Two-wire transmitters for measuring gage and absolute pressure Two-wire transmitters for measuring gage pressure SITRANS P : 1 Turn down Sanitary design with various aseptic connections according to EHEDG, FDA and GMP recommendations Parameterization using 3 buttons and HART or PROFIBUS PA Process connection G½, ½-NPT and flange connection available SITRANS P300 and DS III series with PMC connection for the paper industry 100 : 1 Turn down Process connections for the paper industry Parameter assignment over 3 buttons and HART, PROFIBUS PA or FOUNDATION Fieldbus /19 SIMATIC PDM /35 SIMATIC PDM Two-wire transmitters for measuring: Gage pressure, Absolute pressure Differential pressure and Flow or Level Supplementary electronics for adaptation of two-wire transmitters for four-wire connections SITRANS P, DS III series SITRANS P, DS III PA series SITRANS P, DS III FF series 100 : 1 Turn down Parameterization using: 3 pushbuttons and HART for DS III series 3 pushbuttons and PROFIBUS-PA for DS III PA series 3 buttons and FOUNDATION Fieldbus for DS III FF series Available ex stock /51 SIMATIC PDM SIMATIC PDM Output: 0 or 4 to 0 ma /119 Power supply: 4 V AC/DC, 30 V AC -wire transmitter for measuing hydrostatic levels SITRANS P, MPS series (submersible sensor) For measuring liquid levels in wells, tanks, channels, dams etc. /130 / Siemens FI US Edition

3 Siemens AG 007 Product overview Application Description Page Software for Parameterization Remote seals for measuring viscous, corrosive or fibrous media (as well as media at extreme temperatures) Remote seals in pancake and flange designs Quick-release remote seals for the food industry Wide range of diaphragm materials and filling liquids available /133 Shutting off the lines for the medium and differential pressure Mounting of transmitter on valve manifold or shut-off fitting Shut-off fittings and valve manifolds available in steel, brass or stainless steel Valve manifolds available for the various process connections of the SITRANS P transmitters /171 Siemens FI US Edition /3

4 Transmitters for gage and absolute pressure Z series for gage and absolute pressure Siemens AG 007 Overview SITRANS P pressure transmitters, Z series for pressure and absolute pressure (7MF ) SITRANS P pressure transmitters, Z series (7MF ), measure the gage and absolute pressure as well as the level of liquids and gases. Benefits High measuring accuracy Sturdy stainless steel housing For aggressive and non-aggressive media For measuring the pressure of liquids, gases and vapor Temperature-compensated measuring cell Compact design Application The pressure transmitter of the Z series for gage pressure and absolute pressure (7MF ) is used above all in the following industrial areas: Chemical industry Pharmaceutical industry Food industry Mechanical engineering Shipbuilding Water supply Design The design of the pressure transmitter is dependent on the measuring range. Measuring range <1 bar (<14.5 psi) Main components: Stainless steel housing with piezo-resistive silicon measuring cell (with stainless steel diaphragm, temperature-compensated) and electronics module Process connection made of stainless steel in diverse designs (see Selection and Ordering data) Electrical connection made using a plug to DIN with the cable inlet M16 x 1.5, ½-14 NPT or round plug connector M1. The pressure transmitters with a nominal range < 1 bar g (< 14.5 psi g) are optionally available with or without explosion protection. Measuring range 1 bar ( 14.5 psi) Main components: Stainless steel housing with ceramic measuring cell and electronics module. The temperature-compensated ceramic measuring cell has a thin-film strain gage which is mounted on a ceramic diaphragm. The ceramic diaphragm can also be used for aggressive media. Process connection made of stainless steel in diverse designs (see Selection and Ordering data) Electrical connection made using a plug to DIN with the cable inlet M16 x 1.5, ½-14 NPT or round plug connector M1. The pressure transmitters with a nominal range 1barg ( 14.5 psi g) are optionally available with or without explosion protection. Function The pressure transmitter measures the gage and absolute pressure as well as the level of liquids and gases. Mode of operation p U const. I 0, U B SITRANS P pressure transmitters, Z series (7MF ), functional diagram The mode of operation of the pressure transmitter is dependent on the measuring range. Measuring range <1 bar (<14.5 psi) The silicon measuring cell of the pressure transmitter has a piezo-resistive bridge to which the operating pressure is transmitted through silicone oil and a stainless steel diaphragm. The measuring cell output voltage is fed to an amplifier and converted into an output current ma. The output current is linearly proportional to the input pressure Measuring range 1 bar ( 14.5 psi) The thin-film measuring cell has a thin-film resistance bridge to which the operating pressure p is transmitted through a ceramic diaphragm. The voltage output from the measuring cell is converted by an amplifier into an output current ma or an output voltage of V DC. The output current and voltage are linearly proportional to the input pressure U I /4 Siemens FI US Edition

5 Siemens AG 007 Transmitters for gage and absolute pressure Z series for gage and absolute pressure Technical specifications SITRANS P pressure transmitters, Z series for gage pressure, absolute pressure and level Mode of operation Measuring range <1 bar Piezo-resistive (<14.5 psi) Measuring range 1 bar Thin-film strain gage ( 14.5 psi) Input Measured variable Gage and absolute pressure Measured range Pressure - Metric bar g ( psi g) - US measuring range psi g Absolute pressure - Metric bar a ( psi a) - US measuring range psi a Output Output signal Current output signal ma Voltage output signal (only measuring range 1 bar (14.5 psi)) VDC Accuracy To EN Error in measurement (at 5 C 0.5% of full-scale value typical (77 F), including conformity error, hysteresis and repeatability) Response time T 99 < 0.1 s Long-term drift Start of scale 0.5% of full scale value/year Full-scale value 0.5% of full scale value/year Influence of ambient temperature Start of scale 0.5%/10 K (0.5%/10 K) of fullscale value Full-scale value 0.5%/10 K (0.5%/10 K) of fullscale value Rated operating conditions Process temperature C (- +48 F) Ambient temperature C ( F) Storage temperature C ( F) Degree of protection to EN 6059 IP65 Design Weight 0.5 kg ( 0.55 lb) Wetted parts materials Measuring cell - Measuring range <1 bar Stainless steel, /316Ti (<14.5 psi) - Measuring range 1 bar Al O 3 96% ( 14.5 psi) Process connection Stainless steel, mat. No /316Ti Gasket Viton Process connection See Selection and Ordering data Power supply U H Terminal voltage on pressure transmitter For current output For voltage output signal (only measuring range 1bar (14.5 psi)) Certificate and approvals Classification according to pressure equipment directive (DRGL 97/3/EC) Dimensional drawings V DC V DC For gases of fluid group 1 and liquids of fluid 1; complies with requirements of article 3, paragraph 3 (sound engineering practice) Explosion protection Intrinsic safety "i" (only with current TÜV 0 ATEX 1953X output) - Identification Ex II 1/G EEx ia IIC T4 Intrinsic safety "T.I.I.S." (only with applied current output) Lloyds Register of Shipping Certificate No. 03/30003 Pressure transmitter 7MF with process connection G½" male, dimensions in mm (inch) Pressure transmitter 7MF with process connection G¼" male, dimensions in mm (inch) Siemens FI US Edition /5

6 Transmitters for gage and absolute pressure Z series for gage and absolute pressure Siemens AG 007 Pressure transmitter 7MF with process connection 7/16-0 UNF male, dimensions in mm (inch) Pressure transmitter 7MF with process connection ½"-14 NPT male, dimensions in mm (inch) Pressure transmitter 7MF with process connection ¼"-18 NPT male, dimensions in mm (inch) Pressure transmitter 7MF with process connection ½"-14 NPT female, dimensions in mm (inch) Pressure transmitter 7MF with process connection ¼"-18 NPT female, dimensions in mm (inch) SITRANS P pressure transmitters, Z series (7MF ), connection diagram, with current output (top) and voltage output (bottom) Schematics 1+ + I - 0 U B Signal R L I 0 Output current U B Power supply R L Load Connections: 1 (+U B ) (-U B ) Signal U 0 R L + U B U 0 Output voltage U B Power supply R L Load Connections: 1 (+U B ) (-U B ) 3 (U 0 ) Pressure transmitter 7MF with process connection G1 male, flush-mounted, dimensions in mm (inch) /6 Siemens FI US Edition

7 Siemens AG 007 Transmitters for gage and absolute pressure Z series for gage and absolute pressure Selection and Ordering data Order No. Order code SITRANS P pressure transmitters for pressure, series Z for gage and absolute pressure or 3-wire system, rising characteristic curve C) 7 MF Measuring range perm. working pressure Burst pressure Min. Max. For gage pressure mbar g ( psi g) -0,6 bar g (-8.7 psi g) 0,6 bar g (8.7 psi g) 1 bar g (14.5 psi g) } 3AA mbar g ( psi g) -0,6 bar g (-8.7 psi g) 0,6 bar g (8.7 psi g) 1 bar g (14.5 psi g) } 3AB mbar g ( psi g) -1 bar g (-14.5 psi g) 1bar g (14.5 psi g) 1.7 bar g (5 psi g) } 3AC mbar g ( psi g) -1 bar g (-14.5 psi g) 1bar g (14.5 psi g) 1.7 bar g (5 psi g) } 3AD mbar g ( psi g) -1 bar g (-14.5 psi g) 3bar g (43.5 psi g) 5 bar g (7 psi g) } 3AG0 Other version for measuring range < 1 bar (< 14.5 psi g), add Order code and plain text: 9AC0 H 1 Y measuring range:... up to... mbar g (psi g) 1) bar g ( psi g) -0,4 bar g (-5.8 psi g) bar g (30 psi g) 5 bar g (7 psi g) } 3BA bar g ( psi g) -0,4 bar g (-5.8 psi g) 3, bar g (45 psi g) 5 bar g (7 psi g) } 3BB bar g ( psi g) -0,8 bar g (-11.6 psi g) 5bar g (7 psi g) 1 bar g (175 psi g) } 3BD bar g ( psi g) -0,8 bar g (-11.6 psi g) 8bar g (115 psi g) 1 bar g (175 psi g) } 3BE bar g ( psi g) -1 bar g (-14.5 psi g) 1 bar g (175 psi g) 5 bar g (360 psi g) } 3BG bar g ( psi g) -1 bar g (-14.5 psi g) 0 bar g (90 psi g) 50 bar g (75 psi g) } 3CA bar g ( psi g) -1 bar g (-14.5 psi g) 3 bar g (460 psi g) 50 bar g (75 psi g) } 3CB bar g ( psi g) -1 bar g (-14.5 psi g) 50 bar g (75 psi g) 10 bar g (1750 psi g) } 3CD bar g ( psi g) -1 bar g (-14.5 psi g) 80 bar g (1150 psi g) 10 bar g (1750 psi g) } 3CE bar g ( psi g) -1 bar g (-14.5 psi g) 10 bar g (1750 psi g) 50 bar g (3600 psi g) } 3CG bar g ( psi g) -1 bar g (-14.5 psi g) 00 bar g (900 psi g) 450 bar g (655 psi g) } 3DA bar g ( psi g) -1 bar g (-14.5 psi g) 30 bar g (4640 psi g) 450 bar g (655 psi g) } 3DB bar g ( psi g) -1 bar g (-14.5 psi g) 500 bar g (750 psi g) 650 bar g (945 psi g) } 3DD bar g ( psi g) -1 bar g (-14.5 psi g) 600 bar g (8700 psi g) 650 bar g (945 psi g) } 3DE Other version for measuring range 1 bar g ( 14.5 psi g), add Order code and plain text: 9AA H 1 Y measuring range:... up to... bar (psi g) 1) For absolute pressure mbar a ( psi a) 0bar a (0 psi a) 3bar a (43.5 psi a) 5bar a (7 psi a) } J) 5AG bar a ( psi a) 0bar a (0 psi a) bar a (30 psi a) 5bar a (7 psi a) } J) 5BA bar a ( psi a) 0bar a (0 psi a) 3, bar a (45 psi a) 5bar a (7 psi a) } J) 5BB bar a ( psi a) 0bar a (0 psi a) 5bar a (7 psi a) 1 bar a (175 psi a) } J) 5BD bar a ( psi a) 0bar a (0 psi a) 8bar a (115 psi a) 1 bar a (175 psi a) } J) 5BE bar a ( psi a) 0bar a (0 psi a) 1 bar a (175 psi a) 5 bar a (360 psi a) } J) 5BG bar a ( psi) 0bar a (0 psi a) 0 bar a (90 psi a) 50 bar a (75 psi a) } J) 5CA bar a ( psi) 0bar a (0 psi a) 3 bar a (460 psi a) 50 bar a (75 psi a) } J) 5CB Other version for measuring range < 1 bar (< 14.5 psi a), add Order code and plain text: measuring range:... up to... mbar a (psi a) Measuring ranges for gage pressure (only for US market) J) 9AB 0 H 1 Y ( psi g) (-3 psi g) (0 psi g) (60 psi g) 4BA ( psi g) (-6 psi g) (30 psi g) (7 psi g) 4BB ( psi g) (-6 psi g) (30 psi g) (7 psi g) 4BC ( psi g) (-6 psi g) (40 psi g) (7 psi g) 4BD ( psi g) (-6 psi g) (60 psi g) (7 psi g) 4BE ( psi g) (-11.5 psi g) (10 psi g) (175 psi g) 4BF ( psi g) (-14.5 psi g) (00 psi g) (360 psi g) 4BG ( psi g) (-14.5 psi g) (300 psi g) (75 psi g) 4CA ( psi g) (-14.5 psi g) (400 psi g) (75 psi g) 4CB ( psi g) (-14.5 psi g) (600 psi g) (1750 psi g) 4CD ( psi g) (-14.5 psi g) (1000 psi g) (1750 psi g) 4CE ( psi g) (-14.5 psi g) (1500 psi g) (3600 psi g) 4CF ( psi g) (-14.5 psi g) (000 psi g) (3600 psi g) 4CG ( psi g) (-14.5 psi g) (3000 psi g) (655 psi g) 4DA ( psi g) (-14.5 psi g) (4000 psi g) (655 psi g) 4DB ( psi g) (-14.5 psi g) (6000 psi g) (945 psi g) 4DD ( psi g) (-14.5 psi g) (8700 psi g) (945 psi g) 4DE ( psi g) (-14.5 psi g) (8700 psi g) (945 psi g) 4DF Other version, add Order code and plain text: Measuring range:... up to... psi g 9BA H 1 Y } Available ex stock C) Subject to export regulations AL: N, ECCN: EAR99. J) Subject to export regulations AL: 9I999, ECCN: EAR99. 1) The transmitters can also be ordered with special measuring ranges, e.g. transmitters with a 1-bar measuring cell (14.5 psi measuring cell): bar g ( psi g) or bar g ( psi g) or... Siemens FI US Edition /7

8 Transmitters for gage and absolute pressure Z series for gage and absolute pressure Siemens AG 007 Selection and Ordering data Order No. Order code SITRANS P pressure transmitters for pressure, series Z for pressure and absolute pressure or 3-wire system, rising characteristic curve C) 7 MF Measuring range Perm. working pressure Burst pressure min. max. Measuring ranges for absolute pressure (only for US market) ( psi a) (0 psi a) (0 psi a) (60 psi a) J) 6AG ( psi a) (0 psi a) (30 psi a) (7 psi a) J) 6BA ( psi a) (0 psi a) (40 psi a) (7 psi a) J) 6BB ( psi a) (0 psi a) (60 psi a) (7 psi a) J) 6BD ( psi a) (0 psi a) (10 psi a) (175 psi a) J) 6BE ( psi a) (0 psi a) (00 psi a) (360 psi a) J) 6BG ( psi a) (0 psi a) (300 psi a) (75 psi a) J) 6CA ( psi a) (0 psi a) (400 psi a) (75 psi a) J) 6CB ( psi a) (0 psi a) (600 psi a) (175 psi a) J) 6CC Other version, add Order code and plain text: Measuring range:... up to... psi a J) 9BB H 1 Y Output signal ma;c -wire system; power supply V DC } V; 3-wire system; power supply V DC 1 0 Explosion protection Without } 0 With explosion protection Ex II 1/ G EEx ia IIC T4 (only for version ma; -wire system; 1 power supply V DC) With explosion protection "Intrinsic safety T.I.I.S." (available soon) Electrical connection Plug to DIN 43650, Form A, cable inlet M16 x 1.5 } 1 Round connector M1, IP67 Plug to DIN 43650, cable inlet ½-14 NPT 3 Plug to DIN 43650, cable inlet Pg11 4 Cable gland Pg11 with m cable, IP68 6 Special version (specify Order code and plain text) 9 N 1 Y Process connection G½" male to EN (½" BSP male) (standard for metric pressure ranges mbar, bar) } A G½" male thread and G1/8" female thread B G¼ male to EN837-1 (¼ BSP male) C 7/16"-0 UNF male D ¼"-18 NPT male (standard for pressure ranges psi) E ¼"-18 NPT female F ½"-14 NPT male G ½"-14 NPT female H RC ½" male to JIS B 7505 K G1" male (only for measuring ranges 1 bar g (14.5 psi g)) M Special version (specify Order code and plain text) Z P 1 Y Sealing material between sensor and housing Viton (standard) } A Neoprene B Perbunan C Special version (specify Order code and plain text) Z Q 1 Y Further designs Manufacturer s test certificate M to DIN 55340, Part 18 and ISO 840 (calibration certificate), add "-Z" to Order No. and Order code. Oxygen version, oil and grease-free cleaning (only if the sealing material between sensor and housing is Viton and only for measuring ranges 1 bar g ( 14.5 psi g) and 1 bar a ( 14.5 psi a) Manufacturer s test certificate M to DIN 55340, Part 18 and ISO 840 (calibration certificate) supplied later, specify factory no. of transmitter. } Available ex stock C) Subject to export regulations AL: N, ECCN: EAR99. J) Subject to export regulations AL: 9I999, ECCN: EAR99. Order code / Order No. C11 E10 7MF1564-8CC11 /8 Siemens FI US Edition

9 Overview Siemens AG 007 Transmitters for gage and absolute pressure ZD series for gage and absolute pressure At the rear of the housing is the electrical connection for the voltage supply using a current loop ma. The connection is made with a plug connector. At the front of the housing is the 5-digit display behind a glass cover. Underneath the display are the 3 keys for parameterizing the pressure transmitter. Above the display are a green and a red LED for indicating the operating status. The ZD pressure transmitter is available in two versions (see "Dimension drawing"): In the radial version (type A) the display is fitted in parallel with the process connection. The display can be rotated by up to ±10 relative to the process connection. In the axial version (type B) the display is at right angles to the process connection. The display can be rotated by 360 relative to the process connection. Function Uref Green LED Red LED LCD P A/D µc mbar SITRANS P pressure transmitters, ZD series, are for measuring the gage pressure, absolute pressure and level of liquids and gases. They are used to indicate and monitor the pressure measured at the point of installation. ZD pressure transmitters are available in an axial and a radial version. Benefits Robust stainless steel housing with connection versions Integrated display with status messages Thin-film measuring cell with ceramic diaphragm -wire system, ma Parameterizable using keys underneath the housing cover 5:1 Turn down (max. 10:1) Measuring accuracy < 0.5% (typical) Application The ZD is a configurable pressure transmitter for measuring the gage and absolute pressure of gases, liquids and vapor. It is equipped with a display for indicating the pressure value at the point of installation. SITRANS P pressure transmitters, ZD series, are used in the following industrial areas for example: Chemical industry Mechanical engineering Food industry Pharmaceutical industry Shipbuilding Water supply Design The pressure transmitter is comprised of a thin-film measuring cell with a ceramic diaphragm, an electronics board and a digital indicator. All parts are accommodated in a stainless steel field housing ( 80 mm) with a glass cover and stainless steel process connection. EEPROM D/A 3 keys U K U A U I EMC 3 keys Configuring of parameters A/D Analog-to-digital converter D/A Digital-to-analog converter EEPROM Memory for all parameters EMC Output stage with protective components I A Output current U ref Reference voltage LCD Display of measured values with dimensions Green LED Display of normal mode Red LED Display of error messages or limit violation P Ceramic measuring cell U H Power supply µc Microcontroller for computing functions and monitoring ma U H, I A - SITRANS P pressure transmitters, ZD series, mode of operation Mode of operation The ZD pressure transmitter has a thin-film strain gage which is mounted on a ceramic diaphragm. The measuring cell is temperature-compensated. Functions The ZD pressure transmitter has a 5-digit display behind a glass cover. The following data are shown on the display: Measured pressure Pressure units (default setting: bar) Limit violation in upward or downward direction, indicated by LED and arrow symbols in the display The pressure transmitter is set using the 3 pushbuttons behind the glass cover underneath the display. The key "M" is used to select the operating mode. Following modes of operation are available: Measured value Password Pressure units End of scale Upper and lower limit value Zero adjustment Siemens FI US Edition /9

10 Transmitters for gage and absolute pressure ZD series for gage and absolute pressure Siemens AG 007 Upper and lower current saturation limit Electrical damping The other two keys are used to set the values in the individual operating modes. Two LED indicators are fitted above the display to monitor the set range and the status. The green LED signals that the measured pressure lies within the set limits. The red LED lights up when the measured pressure lies outside the set limits and when there is an error. Technical specifications SITRANS P pressure transmitters, ZD series Mode of operation Measuring principle Thin-film strain gage Input Measured variable Gage and absolute pressure Measured range Resolution 0... bar ( psi) 0.6 mbar (0.008 psi) bar ( psi) 3 mbar (0.044 psi) bar ( psi) 15 mbar (0.18 psi) bar ( psi) 60 mbar (0.9 psi) bar ( psi) 10 mbar (1.8 psi) Measured range Overload limit 0...bar (0...9psi) 5bar (7.5psi) bar ( psi) 5 bar (363 psi) bar ( psi) 10 bar (1740 psi) bar ( psi) 500 bar (750 psi) bar ( psi) 600 bar (8700 psi) Turndown 5:1 Output Output signal ma Lower current limit min. 3.6 ma Upper current limit max. 3 ma Output protected against Reversed polarity, overvoltage and short-circuiting Max. load R B = (U H - 1 V) / 0.03 A Voltage measurement Linear rising Measuring accuracy To EN Error in measurement (including non-linearity, hysteresis and repeatability, at 5 C (77 F)) Adjustment time Long-term drift < 0.5% of full-scale value (typical), max. 0.5% < 100 ms 0.5% of full scale value/year Influence of ambient temperature < ±0.5%/10 K (< ±0.5%/10 K) of full-scale value Vibration influence 0.05%/g to 500 Hz in all directions (to IEC ) Power supply effect < ±0.01%/V of full-scale value Rated conditions Ambient conditions Ambient temperature C ( F) Storage temperature C ( F) Medium conditions Process temperature C ( F) Degree of protection IP65 to EN 6059 Electromagnetic compatibility Emitted interference and interference immunity Displays and controls Display Decimal point Limit values Limit violation display Parameterization Units Damping Design Weight Electrical connection Process connection Version of housing/process connection Material Non-wetted parts materials Field housing To EN 6136/A1 appendix A (1998) LCD, max. 5 digits, digit height 9mm Freely parameterizable Freely parameterizable Red LED and message on LCD ( symbol / symbol in case of limit violation in upward / downward direction) With 3 pushbuttons ma or % or pressure units (default setting: bar) Other dimensions: mbar, kpa, MPa, mmh O, mh O, psi, inh O, mmhg, kg/cm², torr, atm Between 0.1 and 100 s (increment: 0.1 s) freely parameterizable 0.6 kg ( 1.3 lb) Using -pole plug connector with M16x1.5-Cable inlet to EN A, plastic Male thread G½B and female thread G 1 / 8 B G½B to EN Female thread: ½-14 NPT Radial (type A), can be swiveled by max. ±10 (α) Axial (type B), can be swiveled by max. ±360 Ø 80 mm (3.15 inch), stainless steel mat. No Cover Stainless steel, mat. No with glass Wetted parts materials Measuring cell Al O 3 Gasket Viton Process connection Stainless steel, mat. No /316Ti Power supply Terminal voltage on pressure transmitter (U H ) V DC Certificate and approvals Classification according to pressure equipment directive 97/3/EC For gases of fluid group 1 and liquids of fluid 1; complies with requirements of article 3, paragraph 3 (sound engineering practice) /10 Siemens FI US Edition

11 Siemens AG 007 Transmitters for gage and absolute pressure ZD series for gage and absolute pressure Dimensional drawings Ø 8 (3.3) s 45 (1.77) 48,5 (1.91) 48,5 (1.91) Ø 8 (3.3) a M SW 7 Ø 8 (3.3) M16x1,5 or ½-NPT M16x1,5 or ½-NPT 45 (1.77) 15 (5.98) G½B EN ½-14 NPT G½B G 1 /8B Type A Type B SITRANS P pressure transmitters, ZD series, dimensional drawing, dimensions in mm (inch) Schematics 1 (+) 1 (-) U B R L I 0 Power supply Load Output current I 0 R L SITRANS P pressure transmitters, ZD series, connection diagram + U B Selection and Ordering data SITRANS P pressure transmitters, ZD series for gage and absolute pressure Conformity error 0.5%, turndown 5 : 1 (max. 10 : 1), housing and process connection made of stainless steel, membrane made of ceramic, -wire system, output ma Input variable F) Subject to export regulations AL: 9I999, ECCN: N. Order No. 7 M F Gage pressure } 1 Absolute pressure } F) Measured range Span 0...bar ( psi) / bar ( / 9 psi) } D bar ( psi) bar ( psi) bar ( psi) bar ( psi) Process connection 0... / 10 bar ( / 145 psi) / 50 bar ( / 75 psi) / 00 bar ( / 900 psi) / 400 bar ( / 5800 psi) } E } F } G } H G½B male thread and G 1 / 8 B female thread } A G½B to EN B Female thread ½-14 NPT C G 1 male thread M Design Process connection vertically downwards, } 1 thread in connector M16x1.5 Process connection horizontally to rear, thread in connector M16x1.5 Process connection vertically downwards, } 3 thread in connector ½"-14 NPT Process connection horizontally to rear, 4 thread in connector ½"-14 NPT } Available ex stock Siemens FI US Edition /11

12 Siemens AG 007 Transmitters for food, pharmaceuticals and biotechnology SITRANS P Compact for gage and absolute pressure Overview Application The SITRANS P Compact pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials guarantees compliance with hygiene regulations. The SITRANS P Compact pressure transmitter is available in many versions. Exact adaptation of the pressure transmitter to conditions at the place of use is thus possible The SITRANS P Compact pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials guarantees compliance with hygiene regulations. Particular value has been placed on a high surface quality. It is therefore possible, for example, to guarantee roughness values down to R a =0.4µm ( inch) in the wetted area (welded seam area R a <0.8µm ( inch)). The system can be electropolished in addition. A further important feature is the sanitary design of the process connection by means of various aseptic connections. The completely welded stainless steel housing can be designed up to degree of protection IP67. Using appropriate thermal decouplers, the SITRANS P Compact pressure transmitter can be used for process temperatures up to 00 C (39 F). Benefits Measuring ranges from 0 to 160 mbar (0 to.3 psi) to 0 to 40 bar (0 to 580 psi) Linearity error including hysteresis < +0.% of full-scale value Piezo-resistive measurement system, vacuum-proof and overload-proof Sanitary design according to EHEDG, FDA and GMP recommendations Material and surface quality according to hygiene requirements Wetted parts made of stainless steel; completely welded Signal output 4 to 0 ma (0 to 0 ma as option) Stainless steel housing with degree of protection IP65 (IP67 as option) Process temperature up to 00 C (39 F) Explosion protection II G EEx [ib] IIC T6 to ATEX Easy and safe to clean Design The electronics is potted to protect it against moisture, corrosive atmospheres and vibration. Notes on operating the pressure transmitter Compensation of internal atmospheric pressure Compensation of the internal atmospheric pressure of the SITRANS P Compact pressure transmitters is performed as follows: in the plug versions by means of the screwed gland (IP65) in the field housings by means of an integral sintered filter (IP65) or a vented cable (IP67) in versions with cable outlet by means of a vented cable (IP67) In the absolute pressure range there is no need for compensation with respect to atmospheric pressure. Note: These degrees of protection are only achieved under the following conditions: if the pressure transmitter is installed correctly if the screwed glands are securely tightened if the cable diameters agree with the nominal diameters of the gaskets in the housing Note: The integral EMC measures are only effective if the earth connection is made correctly. CE marking The CE marking of the pressure transmitter certifies compliance with the guidelines of the European Council (9/336/EC), the EMC law ( ), as well as the applicable generic standards. Interference-free operation in systems and plants is achieved only if the specifications for shielding, earthing, cable routing and electrical isolation are observed during installation and assembly. Hazardous areas Note: Electrical equipment in hazardous areas must only be installed and operated by trained personnel. Modifications to units and connections result in cancellation of the explosion protection and guarantee. With intrinsically-safe circuits, make sure that equipotential bonding exists throughout the complete cabling inside and outside of the hazardous area. The limits specified in the ATEX approval must be observed. /1 Siemens FI US Edition

13 Siemens AG 007 Transmitters for food, pharmaceuticals and biotechnology SITRANS P Compact for gage and absolute pressure Function The process pressure acts on a piezo-resistive semiconductor measuring bridge through a remote seal and a transmission liquid. The pressure transmitter converts the pressure values into a load-independent current. A compensation network makes the output signal largely independent of the ambient temperature. As a result of a specially adapted remote seal connection with minimized volume, the influence of the process temperature on the output signal is greatly reduced compared to a conventional screw connection. The pressure transmitters can be powered with a non-regulated DC voltage of 10 to 30 V. Output signals common to measuring technology are available. Technical specifications Pressure transmitters for food, pharmaceuticals and biotechnology Mode of operation Measuring principle Piezo-resistive Input Measured variable Gage or absolute pressure Measured range mbar ( psi) bar ( psi) Output Output signal Two-wire system ma Three-wire system ma Measuring accuracy To EN Linearity error including hysteresis 0.% of full-scale value (reference point adjustment) Adjustment accuracy ± 0.% of full-scale value Adjustment time < 0 ms Influence of ambient temperature On th enclosure Zero < 0.%/10 K of full-scale value Measured span < 0.%/10 K of full-scale value On the process connection (remote Zero error (depends on design) seal) Flange remote seal - DN 5 / 1" 4.8 mbar/10 K (0.070 psi/10 K) - DN 3 / 1¼.3 mbar/10 K (0.033 psi/10 K) - DN 40 / 1½ 1.6 mbar/10 K (0.03 psi/10 K) - DN 50 / " 0.6 mbar/10 K (0.009 psi/10 K) Clamp-on seal - DN 5 / 1" 9.5 mbar/10 K (0.138 psi/10 K) - DN 3 / 1¼ 4.1 mbar/10 K (0.060 psi/10 K) - DN 40 / 1½ 3.9 mbar/10 K (0.057 psi/10 K) - DN 50 / " 3.9 mbar/10 K (0.057 psi/10 K) The zero error specified for the process connection should be considered as a guideline for a standard design. We will produce a detailed system calculation on request. Systems with reduced remote seal errors are available on request. Rated conditions Installation conditions Mounting position Any, vertical as standard Ambient conditions Ambient temperature C ( F) Storage temperature C ( F) Process temperature Max. 00 C (39 F), depends on design Degree of protection (to EN 6059) IP65, optional IP67 Electromagnetic compatibility - Emitted interference To EN Part 1, issue 1993 (residential and industrial areas). The unit has no own emissions. - Interference immunity to EN 5008 Part, issue March 1995 (industrial areas) Design Weight (without remote seal) Field housing 460 g ( 1.01 lb) Housing with plug 00 g ( 0.44 lb) Housing Designs Field housing IP65 or IP67, with screwed gland Angled plug DIN 43650, IP65 Cable connection, IP67 Round plug connector M1, IP65 Material Stainless steel, mat. No / Material of union nut Polyamide (with electrical connection using plug or cable) Electronics unit potted with silicone Internal ventilation for measuring ranges < 16 bar (< 3 psi), through housing thread or connection cable depending on design Process connection Versions See Ordering data Material of coupling Stainless steel, mat. No /316L Power supply Terminal voltage on transmitter V DC Rated voltage 4 V DC Certificate and approvals Classification according to pressure equipment directive (DRGL 97/3/EC) For gases of fluid group 1 and liquids of fluid group 1; complies with the requirements of article 3, paragraph 1 (appendix 1); assigned to category III, conformity evaluation module H by the TÜV Nord Explosion protection Intrinsic safety "i" TÜV 03 ATEX 099 X - Identification Ex II G EEx ib IIC T6 Siemens FI US Edition /13

14 Transmitters for food, pharmaceuticals and biotechnology SITRANS P Compact for gage and absolute pressure Selection and Ordering data Order No. Ord. code SITRANS P Compact pressure transmitters 7 M F for pressure and absolute pressure with diaphragm flush at front -wire system Process temperature up to 140 C (84 F) Accuracy: 0.% of full-scale value Output ma Diaphragm seal with quick-release clamp Milk pipe union to DIN with slotted union nut DN5 A D DN3 A E DN40 A F DN50 A G DN65 A H Milk pipe union to DIN with threaded socket DN5 B D DN3 B E DN40 B F DN50 B G DN65 B H Clamp connection to DIN 3676 DN5 C D DN40 C F DN50 C G Clamp connection to ISO 85 1 inch D M 1½inch D N inch D P ½inch D Q IDF standard with slotted union nut 1 inch E M 1½inch E N inch E P IDF standard with threaded socket 1 inch F M 1½inch F N inch F P SMS standard with slotted union nut 1 inch GM 1½inch G N inch G P SMS standard with threaded socket 1 inch H M 1½inch H N inch H P DRD flange, without welding-type flange DN 50, PN 40 J H Varivent connection (Tuchenhagen) D = 50, for Varivent housing DN 5 and K F 1 inch D = 68, for Varivent housing K L DN DN 15 and 1½... 6 inch Special version Z A J 1 Y (add Order code and plain text) Filling liquid Vegetable oil 1 medicinal white oil Food oil, FDA-listed 3 Special version 9 L 1 Y (add Order code and plain text) Output signal ma 1 Special version (add Order code and plain text) 9 M 1 Y Siemens AG 007 Selection and Ordering data Order No. Ord. code SITRANS P Compact pressure transmitters 7 M F for pressure and absolute pressure with diaphragm flush at front -wire system Process temperature up to 140 C (84 F) Accuracy: 0.% of full-scale value Output ma Diaphragm seal with aseptic connection Aseptic screwed gland to DIN , form A, with slotted union nut 1 inch P M 1½ inch P N inch P P ½ inch P Q Aseptic screwed gland to DIN , form A with threaded socket 1 inch QM 1½ inch Q N inch Q P ½ inch QQ Aseptic screwed NEUMO with slotted union nut 1) DN5 R D DN3 R E DN40 R F DN50 R G Aseptic screwed NEUMO with threaded socket 1) DN5 S D DN3 S E DN40 S F DN50 S G Aseptic screwed NEUMO with clamp connection, form R 1) DN5 T D DN3 T E DN40 T F DN50 T G Aseptic screwed NEUMO with clamp connection, form V 1) DN5 U D DN3 U E DN40 U F DN50 U G Special version Z A J 1 Y (add Order code and plain text) Filling liquid Vegetable oil 1 medicinal white oil Food oil, FDA-listed 3 Special version 9 L 1 Y (add Order code and plain text) Output signal 4...0mA 1 Special version 9 M 1 Y (add Order code and plain text) 1) Please specify as well: Connections for pipes: R01, R0 or R03, see table "Further designs" on next page /14 Siemens FI US Edition

15 Selection and Ordering data Order No. Ord. code SITRANS P Compact pressure transmitters 7 M F for pressure and absolute pressure with diaphragm flush at front -wire system Process temperature up to 140 C (84 F) Accuracy: 0.% of full-scale value Output ma Housing design (stainless steel mat. No /316L) / electr. connection Housing with angled plug to DIN 43650, 1 IP65 Housing with round plug M1, IP65, union nut made of polyamide Housing with round plug M1, IP65, 3 union nut made of stainless steel Stainless steel field housing (small) with 4 cable gland, IP65 Stainless steel field housing (small) with cable gland, IP67 Internal ventilation for measuring ranges < 10 bar (< 145 psi) 5 Measured range Overload pressure mbar g bar g B B ( psi g) (9 psi g) mbar g bar g B C ( psi g) (9 psi g) mbar g 6bar g B D ( psi g) (87 psi g) mbar g 6bar g B E ( psi g) (87 psi g) bar g 10 bar g C A ( psi g) (145 psi g) bar g 10 bar g C B ( psi g) (145 psi g) bar g 16 bar g C C ( psi g) (3 psi g) bar g ( psi g) 16 bar g (3 psi g) C D bar g ( psi g) bar g ( psi g) bar g ( psi g) bar g ( psi g) bar g ( psi g) mbar g ( psi g) bar g ( psi g) bar g ( psi g) bar g ( psi g) 30 bar g (435 psi g) 30 bar g (435 psi g) 50 bar g (75 psi g) 50 bar g (75 psi g) 70 bar g (1015 psi g) bar g (9 psi g) bar g (9 psi g) 6bar g (87 psi g) 6bar g (87 psi g) Transmitters for food, pharmaceuticals and biotechnology SITRANS P Compact for gage and absolute pressure C E D A D B D C D D E B E C E D E E Siemens AG 007 Selection and Ordering data Order No. Ord. code SITRANS P Compact pressure transmitters 7 M F for pressure and absolute pressure with diaphragm flush at front -wire system Process temperature up to 140 C (84 F) Accuracy: 0.% of full-scale value Output ma Measured range Overload pressure (continued) bar g 10 bar g F A ( psi g) (145 psi g) bar g 10 bar g F B ( psi g) (145 psi g) bar g 16 bar g F C ( psi g) (3 psi g) bar g 16 bar g F D ( psi g) (3 psi g) bar g 30 bar g F E ( psi g) (435 psi g) bar g 30 bar g G A ( psi g) (435 psi g) bar g 50 bar g G B ( psi g) (75 psi g) 0...1bar a 10 bar a F) H A ( psi a) (145 psi a) bar a 10 bar a F) H B ( psi a) (145 psi a) 0...5bar a 16 bar a F) H C ( psi a) (3 psi a) 0...4bar a ( psi a) 16 bar a (3 psi a) F) H D 0...6bar a ( psi a) bar a ( psi a) 30 bar a (435 psi a) 30 bar a (435 psi a) F) H E F) J A Special version Z A (add Order code and plain text) Explosion protection without 1 with, to ATEX 100a, II G, EEx ib IIC T6 Further designs Order code Please add "-Z" to Order No. and specify Order code Hygiene version P01 Roughness of process connection: Foil R a < 0.8 µm ( inch); Welded seams R a < 1.5 µm ( inch) Integral cooling element K01 Process temperature max. 00 C (39 F) instead of 140 C (84 F) Connections for pipe Pipes to DIN R01 ISO pipes to DIN 463 R0 Pipes to O. D. Tubing "BS 485 Part 1" R03 Certificates Use of FDA-listed remote seal filling liquids certified by factory certificate to C17 EN Roughness depth measurement R a C18 certified by factory certificate to EN Certification to EHEDG for clamp-on C19 seals with aseptic screwed gland to DIN P 1 Y F) Subject to export regulations AL: 9I999, ECCN: N. Siemens FI US Edition /15

16 Transmitters for food, pharmaceuticals and biotechnology SITRANS P Compact for gage and absolute pressure Selection and Ordering data Order No. Ord. code SITRANS P Compact pressure transmitters 7 M F for pressure and absolute pressure with clamp-on remote seal -wire system Process temperature up to 140 C (84 F) Accuracy: 0.% of full-scale value Output ma Clamp-on remote seal (screwed gland at both ends) with quick-release clamps Milk pipe union to DIN with threaded socket DN5 A D DN3 A E DN40 A F DN50 A G DN65 A H Clamp connection to DIN 3676 DN5 C D DN3 C E DN40 C F DN50 C G DN65 C H Clamp connection to ISO 85 1) 1 inch DM 1½inch D N inch D P ½inch D Q Special version Z A J 1 Y (add Order code and plain text) Filling liquid Vegetable oil 1 Medicinal white oil Food oil, FDA-listed 3 Special version 9 L 1 Y (add Order code and plain text) Output signal ma 1 Special version 9 M 1 Y (add Order code and plain text) 1) Please note the internal diameter of the pipe. Please specify pipe classes (see "Further designs") Siemens AG 007 Selection and Ordering data Order No. Ord. code SITRANS P Compact pressure transmitters 7 M F for pressure and absolute pressure with clamp-on remote seal -wire system Process temperature up to 140 C (84 F) Accuracy: 0.% of full-scale value Output ma Clamp-on seal with aseptic connection Aseptic screwed gland to DIN , form A with threaded socket 1 inch QM 1½ inch Q N inch Q P Aseptic screwed NEUMO with threaded socket 1) DN5 S D DN3 S E DN40 S F DN50 S G DN65 S H Aseptic screwed NEUMO with clamp connection, form R 1) DN5 T D DN3 T E DN40 T F DN50 T G Aseptic screwed gland SÜDMO with threaded socket W inch V M 1½ inch V N inch V P Aseptic screwed gland SÜDMO with clamp connection W inch WM 1½ inch WN inch WP Special version Z A J 1 Y (add Order code and plain text) Filling liquid Vegetable oil 1 medicinal white oil Food oil, FDA-listed 3 Special version 9 L 1 Y (add Order code and plain text) Output signal 4...0mA 1 Special version 9 M 1 Y (add Order code and plain text) 1) Please specify as well: Connections for pipes: R01, R0 or R03, see table "Further designs" on next page /16 Siemens FI US Edition

17 Selection and Ordering data Order No. Ord. code SITRANS P Compact pressure transmitters 7 M F for pressure and absolute pressure with clamp-on remote seal -wire system Process temperature up to 140 C (84 F) Accuracy: 0.% of full-scale value Output ma Housing design (stainless steel mat. No /316L) / electr. connection Housing with angled plug to DIN 43650, 1 IP65, union nut made of polyamide Housing with round plug M1, IP65, union nut made of polyamide Housing with round plug M1, IP65, union nut made of stainless steel 3 Stainless steel field housing (small) with 4 cable gland, IP65 Stainless steel field housing (small) with cable gland, IP67 Internal ventilation for measuring ranges < 10 bar (< 145 psi) 5 Measured range Overload pressure mbar g bar g B B ( psi g) (9 psi g) mbar g bar g B C ( psi g) (9 psi g) mbar g 6bar g B D ( psi g) (87 psi g) mbar g 6bar g B E ( psi g) (87 psi g) bar g 10 bar g C A ( psi g) (145 psi g) bar g 10 bar g C B ( psi g) (145 psi g) bar g 16 bar g C C ( psi g) (3 psi g) bar g ( psi g) 16 bar g (3 psi g) C D bar g ( psi g) bar g ( psi g) bar g ( psi g) bar g ( psi g) bar g ( psi g) mbar g ( psi g) bar g ( psi g) bar g ( psi g) bar g ( psi g) 30 bar g (435 psi g) 30 bar g (435 psi g) 50 bar g (75 psi g) 50 bar g (75 psi g) 70 bar g (1015 psi g) bar g (9 psi g) bar g (9 psi g) 6bar g (87 psi g) 6bar g (87 psi g) Transmitters for food, pharmaceuticals and biotechnology SITRANS P Compact for gage and absolute pressure C E D A D B D C D D E B E C E D E E Siemens AG 007 Selection and Ordering data Order No. Ord. code SITRANS P Compact pressure transmitters 7 M F for pressure and absolute pressure with clamp-on remote seal -wire system Process temperature up to 140 C (84 F) Accuracy: 0.% of full-scale value Output ma Measured range Overload pressure (continued) bar g 10 bar g F A ( psi g) (145 psi g) bar g 10 bar g F B ( psi g) (145 psi g) bar g 16 bar g F C ( psi g) (3 psi g) bar g 16 bar g F D ( psi g) (3 psi g) bar g 30 bar g F E ( psi g) (435 psi g) bar g 30 bar g G A ( psi g) (435 psi g) bar g 50 bar g G B ( psi g) (75 psi g) 0...1bar a 10 bar a F) H A ( psi a) (145 psi a) bar a 10 bar a F) H B ( psi a) (145 psi a) 0...5bar a 16 bar a F) H C ( psi a) (3 psi a) 0...4bar a ( psi a) 16 bar a (3 psi a) F) H D 0...6bar a ( psi a) bar a ( psi a) 30 bar a (435 psi a) 30 bar a (435 psi a) F) Subject to export regulations AL: 9I999, ECCN: N. F) H E F) J A Special version Z A (add Order code and plain text) Explosion protection without 1 with, to ATEX 100a, II G, EEx ib IIC T6 Further designs Order code Please add "-Z" to Order No. and specify Order code Hygiene version P01 Roughness of process connection: Foil R a < 0.8 µm ( inch); Welded seams R a < 1.5 µm ( inch) Integral cooling element K01 Process temperature max. 00 C (39 F) instead of 140 C (84 F) Connections for pipe Pipes to DIN R01 ISO pipes to ISO 463 R0 Pipes to O. D. Tubing "BS 485 Part 1" R03 Certificates Use of FDA-listed remote seal filling liquids certified by factory certificate C17 to EN Roughness depth measurement R a C18 certified by factory certificate to EN Certification to EHEDG for clamp-on C19 seals with aseptic screwed gland to DIN P 1 Y Siemens FI US Edition /17

18 Transmitters for food, pharmaceuticals and biotechnology SITRANS P Compact for gage and absolute pressure Dimensional drawings Housing Siemens AG 007 Fieldhousing stainless steel Degree of protection IP65 IP67 as alternative ø 50 (diam. 1.97) For cable diam ( ) Angled plug to DIN Degree of protection IP65» 8 (0.3) 39 (1.53) For cable diam ( ) Cable connection Degree of protection IP67 (cable ventilation) Round plug with screw connection M1 Degree of protection IP65» 50 (1.97) 74,5 (.93) 14,5 (4.9) 38,5 (1.5) 74,5 (.93)» 13 (5.),5 (0.9) 74,5 (.93) 107,5 (4.3) 74,5 (.93) 9 (0.35) 94 (3.7) 30 (1.18) Thermal decoupler for process temperature up to 00 C (39 F) Process connections Standard Food screwed gland Union nut to DIN DN Clamp connection to DIN ISO 85 DN ½ Pipe-screwed gland (food) Round thread to DIN DN Pipe clamp connection to DIN DN to ISO ½ Aseptic Aseptic screwed gland Round thread Neumo, Südmo, Guth DIN DN Clamp connection Neumo, Südmo, Guth DN Pipe screwed gland (aseptic) Round thread DIN Neumo, Südmo, Guth DN Pipe clamp connection Neumo, Südmo, Guth DN SITRANS P, dimensions in mm (inch) Schematics Field housing Angled plug Cable connection Round plug Two-wire system 0 V 4 V 0 V 4 V brown yellow green 4 black 1 brown white SITRANS P Compact, connection diagram /18 Siemens FI US Edition

19 Siemens AG 007 Transmitters for gage and absolute pressure SITRANS P300 Overview The SITRANS P300 is a digital pressure transmitter for gage and absolute pressure. All conventional thread versions are available as process connections. In addition, various sanitary connections and flange connections with front-flush diaphragms meet the requirements of a dead space free process connection. The output signal is a load-independent direct current from 4 to 0 ma or a PROFIBUS PA signal, which is linearly proportional to the input pressure. Communication is over HART protocol or over PROFIBUS PA interface. Convenient buttons for easy local operation of the basic settings of the pressure transmitter. The SITRANS P300 has a single-chamber stainless steel casing. The pressure transmitter is approved with "intrinsically safe" type of protection It can be used in zone 1 or zone 0. Benefits High quality and long life High reliability even under extreme chemical and mechanical loads Extensive diagnosis and simulation functions Excellent repeatability Small long-term drift Wetted parts made of high-grade materials (such as stainless steel, Hastelloy) Measuring range 8 mbar to 400 bar (0.1 to 5800 psi) High measuring accuracy Parameterization via pushbuttons and HART communication or PROFIBUS PA communication Application The pressure transmitter is available in versions for gage pressure and for absolute pressure. The output signal is always a load-independent direct current from 4 to 0 ma or a PROFIBUS PA signal, which is linearly proportional to the input pressure. The pressure transmitter measures aggressive, nonaggressive and hazardous gases, as well as vapors and liquids. It can be used for the following measurement types: Gage pressure Absolute pressure With appropriate parameter settings, it can also be used for the following additional measurement types: Level Volume Mass The "intrinsically-safe" EEx version of the transmitter can be installed in hazardous areas (zone 1). The transmitters are provided with an EC type examination certificate and comply with the respective harmonized European standards of ATEX. Gage pressure This variant measures aggressive, non-aggressive and hazardous gases, vapors and liquids. The smallest measuring span is 10 mbar g, the largest 400 bar g (0.1 psi g, the largest 5800 psi g). Level With appropriate parameter settings, the gage pressure model measures the level of aggressive, non-aggressive and hazardous liquids. For measuring the level in an open tank you require a gage transmitter. Absolute pressure This model measures the absolute pressure of aggressive, nonaggressive and hazardous gases, vapors and liquids. The smallest measuring span is 8 mbar a, the largest 30 bar a (0.1 psi a, the largest 435 psi a). Siemens FI US Edition /19

20 Transmitters for gage and absolute pressure SITRANS P300 Siemens AG 007 Design The device comprises: Electronics Housing Measuring cell Function Operation of the electronics with HART communication 8 M mc I A, U H 7 HART interface EEPROM 6 Electronics 1 Sensor EEPROM 6 P e Measuring cell Perspective view of the SITRANS P300 The housing has a screw-on cover (3), with or without an inspection window depending on the version. The electrical terminal housing, the buttons for operation of the device and, depending on the version, the digital display are located under this cover. The connections for the auxiliary power UH and the shield are in the terminal housing. The cable gland is on the side of the housing. The measuring cell with the process connection (5) is located on the underside of the housing. Depending on the version of the device, the measuring cell with the process connection may differ from the one shown in the diagram. 1 Measuring cell sensor Instrument amplifier 3 Analog-to-digital converter 4 Microcontroller 5 Digital-to-analog converter 6 One non-volatile memory each in the measuring cell and electronics 7 HART interface 8 Three input keys (local operation) 9 Digital display 10 Diode circuit and connection for external ammeter I A Output current U H Power supply P e Input variable The input pressure is converted into an electrical signal by the sensor (1). This signal is amplified by the measuring amplifier () and digitalized in an analog to digital converter (3). The digital signal is analyzed in a microcontroller (4) and corrected with regard to linearity and thermal characteristics. In a digital to analog converter (5) it is then converted into the output current of 4 to 0 ma. A diode circuit provides reverse voltage protection. You can make an uninterrupted current measurement with a lowohm ammeter at the connection (10). The data specific to the measuring cell, the electronic data and parameter settings are stored in two non-volatile memories (6). The first memory is linked with the measuring cell, the second with the electronics. The buttons (8) can be used to call up individual functions, socalled modes. If you have a device with a digital display (9), you can use this to track mode settings and other messages. The basic mode settings can be changed with a computer via the HART modem (7). /0 Siemens FI US Edition

21 Siemens AG 007 Transmitters for gage and absolute pressure SITRANS P300 Operation of the electronics with PROFIBUS PA communication Measuring cell for gage pressure 8 M Sensor p e mc PA interface EEPROM 6 Measuring cell EEPROM 1 Measuring cell sensor Instrument amplifier 3 Analog-to-digital converter 4 Microcontroller 5 Electrical isolation 6 One non-volatile memory each in the measuring cell and electronics 7 PROFIBUS-PA interface The input pressure is converted into an electrical signal by the sensor (1). This signal is amplified by the measuring amplifier () and digitalized in an analog to digital converter (3). The digital signal is analyzed in a microcontroller (4) and corrected with regard to linearity and thermal characteristics. It is then made available at the PROFIBUS PA over an electrically isolated PROFIBUS PA interface (7). The data specific to the measuring cell, the electronic data and parameter settings are stored in two non-volatile memories (6). The first memory is linked with the measuring cell, the second with the electronics. The buttons (8) can be used to call up individual functions, socalled modes. If you have a device with a digital display (9), you can use this to track mode settings and other messages. The basic mode settings can be changed with a computer over the bus master (1). 6 Electronics PROFIBUS-PA Power supply 10 Power supply unit Coupler 11 1 Bus- Master 8 Three input keys (local operation) 9 Digital display 10 Power supply 11 DP/PA coupler or link 1 Bus master p e Input variable PROFIBUS-DP Measuring cell for gage pressure, function chart The input pressure (p e ) is transferred to the gage pressure sensor (6) via the seal diaphragm (4) and the filling liquid (5), displacing its measuring diaphragm. The displacement changes the resistance value of the four piezo resistors in the measuring diaphragm in a bridge circuit. The change in the resistance causes a bridge output voltage proportional to the input pressure. The transmitters with spans 63 bar (96.1 psi) measure the input pressure against atmosphere, those with spans 160 bar (35 psi) against vacuum. Measuring cell for absolute pressure p e 1 Reference pressure Measuring cell 3 Process connection 4 Seal diaphragm 5 Filling liquid 6 Relative pressure sensor p e Pressure as input variable 1 Mode of operation of the measuring cells The process connections available include the following: G½ ½-14 NPT Front-flush diaphragm: - Flanges to EN - Flanges to ASME - NuG and pharmaceutical connections p e 1 Measuring cell Process connection 3 Seal diaphragm 4 Filling liquid 5 Absolute pressure sensor p e Pressure as input variable Measuring cell for absolute pressure, function chart The input pressure (p e ) is transferred to the absolute pressure sensor (5) via the seal diaphragm (3) and the filling liquid (4), displacing its measuring diaphragm. The displacement changes the resistance value of the four piezo resistors in the measuring diaphragm in a bridge circuit. The change in the resistance causes a bridge output voltage proportional to the input pressure. Siemens FI US Edition /1

22 Transmitters for gage and absolute pressure SITRANS P300 Siemens AG 007 Measuring cell for gage pressure, front-flush diaphragm 5 1 The input pressure (pe) is transferred to the absolute pressure sensor (5) via the seal diaphragm (3) and the filling liquid (4), displacing its measuring diaphragm. The displacement changes the resistance value of the four piezo resistors in the measuring diaphragm in a bridge circuit. The change in the resistance causes a bridge output voltage proportional to the input pressure. Parameterization of SITRANS P300 Depending on the version, there are a range of options for parameterizing the pressure transmitter and for setting or scanning the parameters. Parameterization using the pushbuttons (local operation) 4 With the pushbuttons you can easily set the most important parameters without any additional equipment. Parameterization using HART communication Parameterization using HART communication is performed with a HART communicator or a PC. 1 Reference pressure Measuring cell 3 Seal diaphragm 4 Filling liquid 5 Relative pressure sensor p e Pressure as input variable 3 SITRANS P transmitter W + Power supply Measuring cell for gage pressure, front-flush diaphragm, function chart The input pressure (p e ) is transferred to the gage pressure sensor (6) via the seal diaphragm (4) and the filling liquid (5), displacing its measuring diaphragm. The displacement changes the resistance value of the four piezo resistors in the measuring diaphragm in a bridge circuit. The change in the resistance causes a bridge output voltage proportional to the input pressure. The transmitters with spans 63 bar measure the input pressure against atmosphere, those with spans 160 bar against vacuum. Measuring cell for absolute pressure, front-flush diaphragm Communication between a HART communicator and a pressure transmitter When parameterizing with the HART communicator, the connection is made directly to the -wire system. SITRANS P transmitter HART communicator HART modem W PC or laptop Power supply RS HART communication between a PC communicator and a pressure transmitter When parameterizing with a PC, the connection is made through a HART modem. The signals needed for communication in conformity with the HART 5.x or 6.x protocols are superimposed on the output current using the Frequency Shift Keying (FSK) method. 3 1 Measuring cell Seal diaphragm 3 Filling liquid 4 Absolute pressure sensor p e Pressure as input variable Measuring cell for absolute pressure, front-flush diaphragm, function chart / Siemens FI US Edition

23 Siemens AG 007 Transmitters for gage and absolute pressure SITRANS P300 Adjustable parameters on SITRANS P300 with HART communication Parameters Pushbuttons HART communication Start of scale x x Full-scale value x x Electrical damping x x Start-of-scale value without application x x of a pressure ("Blind setting") Full-scale value without application of a x x pressure ("Blind setting") Zero adjustment x x Current transmitter x x Fault current x x Disabling of keys, write protection x x 1) Type of dimension and actual dimension x x Input of characteristic x Freely-programmable LCD x Diagnostics functions x 1) Cancel apart from write protection Diagnostic functions for SITRANS P300 with HART communication Zero correction display Event counter Limit transmitter Saturation alarm Slave pointer Simulation functions Maintenance timer Available physical units of display for SITRANS P300 with HART communication Physical variable Physical dimensions Pressure (setting can also be made in the factory) Level (height data) Volume Mass Temperature K, C, F, R Miscellaneous %, ma Pa, MPa, kpa, bar, mbar, torr, atm, psi, g/cm, kg/cm, inh O, inh O (4 C), mmh O, fth O (0 C), inhg, mmhg m, cm, mm, ft, in m 3, dm 3, hl, yd 3, ft 3, in 3, US gallon, lmp. gallon, bushel, barrel, barrel liquid g, kg, t, lb, Ston, Lton, oz Adjustable parameters for P300 PA and FF Parameters Pushbuttons PROFIBUS PA and (DS III FOUNDATION HART) Fieldbus interface Electrical damping x x Zero adjustment (correction of x x position) Key and/or function disabling x x Source of measured-value display x x Physical dimension of display x x Position of decimal point x x Bus address x x Adjustment of characteristic x x Input of characteristic x Freely-programmable LCD x Diagnostics functions x Diagnostic functions for P300 PA and FF Event counter Min/Max registers Maintenance timer Simulation functions Display of zero correction Limit transmitter Saturation alarm Physical dimensions available for the display Physical variable Physical dimensions Pressure (setting can also be made in the factory) Level (height data) Volume MPa, kpa, Pa, bar, mbar, torr, atm, psi, g/cm, kg/cm, mmh O, mmh O (4 C), inh O, inh O (4 C), fth O (0 C), mmhg, inhg m, cm, mm, ft, in, yd m 3, dm 3, hl, yd 3, ft 3, in 3, US gallon, lmp. gallon, bushel, barrel, barrel liquid Volume flow m 3 /s, m 3 /min, m 3 /h, m 3 /d, l/s, l/min, l/h, l/ d, Ml/d, ft 3 /s, ft 3 /min, ft 3 /h, ft 3 /d, US gallon/s, US gallon/min, US gallon/h, US gallon/d, bbl/s, bbl/min, bbl/h, bbl/d Mass flow g/s, g/min, g/h, g/d, kg/s, kg/min, kg/h, kg/d, t/s, t/min, t/h, /t/d, lb/s, lb/min, lb/h, lb/d, STon/s, STon/min, STon/h, STon/d, LTon/s, LTon/min, LTon/h, LTon/d Total mass flow t, kg, g, lb, oz, LTon, STon Temperature K, C, F, R Miscellaneous % Parameterization through PROFIBUS PA interface Fully digital communication through PROFIBUS PA, profile 3.0, is particularly user-friendly. The PROFIBUS puts the DS III PA is in connection with a process control system, e.g. SIMATIC PSC 7. Communication is possible even in a potentially explosive environment. For parameterization through PROFIBUS you need suitable software, e.g. SIMATIC PDM (Process Device Manager). Parameterization through FOUNDATION Fieldbus Interface Fully digital communication through FOUNDATION Fieldbus is particularly user-friendly. Through the FOUNDATION Fieldbus the DS III FF is connected to a process control system. Communication is possible even in a potentially explosive environment. For parameterization through the FOUNDATION Fieldbus you need suitable software, e.g. National Instruments Configurator. Sanitary version In the case of the SITRANS P300 with 7MF front-flush diaphragm, selected connections comply with the requirements of the EHEDG or 3A. You will find further details in the order form. Please note in particular that the seal materials used must comply with the requirements of 3A. Similarly, the filling liquids used must be FDA-compliant. Siemens FI US Edition /3

24 Transmitters for gage and absolute pressure SITRANS P300 Siemens AG 007 Technical specifications F SITRANS P300 for gage pressure and absolute pressure Gage pressure input Measured variable Spans (infinitely adjustable) or nominal measuring range and max. pemissible test pressure HART Gage pressure (flush-mounted) Span Max. perm. test pressure bar g ( psi g) bar g ( psi g) bar g ( psi g) bar g ( psi g) bar g ( psi g) bar g ( psi g) 6 bar g (87 psi g) 10 bar g (145 psi g) 3 bar g (464 psi g) 100 bar g (1450 psi g) 50 bar g (366 psi g) 600 bar g (8700 psi g) PROFIBUS PA and FOUNDATION Fieldbus Nominal measuring range 1 bar g (14.5 psi g) 4 bar g (58 psi g) 16 bar g (3 psi g) 63 bar g (914 psi g) 160 bar g (31 psi g) 400 bar g (580 psi g) Max. perm. test pressure 6 bar g (87 psi g) 10 bar g (145 psi g) 3 bar g (464 psi g) 100 bar g (1450 psi g) 50 bar g (366 psi g) 600 bar g (8700 psi g) Depending on the process connection, the span may differ from these values Lower measuring limit Measuring cell with silicone oil 30 mbar a (0.44 psi a) Upper measuring limit Measuring cell with silicone oil 100% of max. span 100% of the max. nominal measuring range Absolute pressure input Measured variable Absolute pressure Spans (infinitely adjustable) or nominal measuring range and max. pemissible test pressure Span Max. perm. test pressure Nominal measuring range Max. perm. test pressure mbar a ( psi a) 6 bar a (87 psi a) 50 mbar a (3.6 psi a) 6 bar a (87 psi a) bar a ( psi a) 10 bar a (145 psi a) 1.30 bar a (19 psi a) 10 bar a (145 psi a) bar a ( psi a) 30 bar a (435 psi a) 5 bar a (73 psi a) 30 bar a (435 psi a) bar a ( psi a) 100 bar a (1450 psi a) 30 bar a (435 psi a) 100 bar a (1450 psi a) Lower measuring limit Measuring cell with silicone oil 0 mbar a (0 psi a) Upper measuring limit Measuring cell with silicone oil 100% of max. span 100% of the max. nominal measuring range Input of gage pressure, with front-flush diaphragm Measured variable Gage pressure Spans (infinitely adjustable) or nominal measuring range and max. pemissible test pressure Span Max. perm. test pressure Nominal measuring range Max. perm. test pressure mbar g ( psi g) bar g ( psi g) bar g ( psi g) bar g ( psi g) bar g ( psi g) 6 bar g (87 psi g) 6 bar g (87 psi g) 10 bar g (145 psi g) 3 bar g (464 psi g) 100 bar g (1450 psi g) Depending on the process connection, the span may differ from these values 50 mbar g (3.6 psi g) 1 bar g (14.5 psi g) 4 bar g (58 psi g) 16 bar g (3 psi g) 63 bar g (914 psi g) 6 bar g (87 psi g) 6 bar g (87 psi g) 10 bar g (145 psi g) 3 bar g (464 psi g) 100 bar g (1450 psi g) /4 Siemens FI US Edition

25 Siemens AG 007 Transmitters for gage and absolute pressure SITRANS P300 SITRANS P300 for gage pressure and absolute pressure HART PROFIBUS PA and FOUNDATION Fieldbus Lower measuring limit Measuring cell with silicone oil 100 mbar a (1.45 psi a) Upper measuring limit Measuring cell with silicone oil 100% of max. span 100% of the max. nominal measuring range Output Output signal ma Digital PROFIBUS PA signal Physical bus - IEC With polarity reversal protection No Yes Electrical damping T 63 (step width 0.1 s) Set to 0.1 s ( s) Accuracy To EN Reference conditions Increasing characteristic, start-of-scale value 0 bar, stainless steel seal diaphragm, measuring cell with silicone oil, room temperature 5 C (77 F), span ratio (r = max. span / set span) Measurement deviation with cut-off point setting, including hysteresis and repeatability. Gage pressure Absolute pressure Gage pressure Absolute pressure Linear characteristic curve 0,075% 0,075% r 10 (0.009 r )% 0,1% 10 < r 30 ( r )% 0,% 30 < r 100 (0.005 r )% - Settling time T 63 without electrical damping Approx. 0. s Long-term drift at ± 30 C (± 54 F) (0.5 r)%/5 years (0.1 r)%/year 0.5%/5 years 0.1%/year Influence of ambient temperature at C ( F) (0.1 r +0.)% 0,3% at C and C (0.1 r )% / 10 K 0.5%/ 10 K ( F and F) Influence of the medium temperature (only with front-flush diaphragm) Temperature difference between medium 3 mbar/10 K (0.04 psi/10 K) temperature and ambient temperature Rated operating conditions Installation conditions Ambient temperature Observe the temperature class in areas subject to explosion hazard. Measuring cell with silicone oil C ( F) Measuring cell with medical whiteoil and C ( F) Neobee oil (with front-flush diaphragm) Measuring cell with inert liquid (not with C ( F) front-flush diaphragm) Digital display C ( F) Storage temperature C ( F) Climatic class Condensation Permissible Degree of protection to EN 6059 IP65, IP68, NEMA X, enclosure cleaning, resistant to lyes, steam to 150 C (30 F) Electromagnetic compatibility Emitted interference and interference immunity To EN 6136 and NAMUR NE 1 Medium conditions Process temperature Measuring cell with silicone oil C ( F) Measuring cell with silicone oil (with frontflush C ( F) diaphragm) Measuring cell with medical whiteoil and C ( F) Neobee oil (with front-flush diaphragm) Measuring cell with silicone oil, with temperature C ( F) isolator (only with front-flush dia- phragm) Measuring cell with inert liquid C ( F) Siemens FI US Edition /5

26 Transmitters for gage and absolute pressure SITRANS P300 Siemens AG 007 SITRANS P300 for gage pressure and absolute pressure HART PROFIBUS PA and FOUNDATION Fieldbus Design (standard version) Weight (without options) Approx. 800 g (1.8 lb) Housing material Stainless steel, mat. No /304 Material of parts in contact with the medium Connection shank Stainless steel, mat. No /316L or Hastelloy C76, mat. No Oval flange Stainless steel, mat. No /316L Seal diaphragm Stainless steel, mat. No /316L or Hastelloy C76, mat. No Measuring cell filling Silicone oil Inert filling liquid Process connection G½A to DIN EN Female thread ½-14 NPT Oval flange PN 160 (MWP 30 psi) with fastening thread: - 7 / 16-0 UNF to IEC M10 as per DIN 1913 Design (version with front-flush diaphragm) Weight (without options) Approx kg ( lb) Housing material Stainless steel, mat. No /304 Material of parts in contact with the medium Process connection Stainless steel, mat. No /316L Seal diaphragm Stainless steel, mat. No /316L Measuring cell filling Silicone oil Inert filling liquid FDA compliant fill fluid Process connection Flanges as per EN and ASME F&B and pharmaceutical flanges Power supply U H Terminal voltage on transmitter V DC for intrinsically safe operation: V DC Supplied through bus Separate power supply - Not necessary Bus voltage Without EEx V For intrinsically-safe operation V Current consumption Max. basic current ma Startup current basic current - Yes Max. fault current in the event of a fault ma Fault disconnection electronics (FDE) - Available /6 Siemens FI US Edition

27 Siemens AG 007 Transmitters for gage and absolute pressure SITRANS P300 SITRANS P300 for gage pressure and absolute pressure HART PROFIBUS PA and FOUNDATION Fieldbus Certificate and approvals Classification according to pressure equipment directive (DRGL 97/3/EC) For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of Article 3, paragraph 3 (sound engineering practice) Water, waste water Available soon Explosion protection Intrinsic safety "i" PTB 05 ATEX 048 Identification Ex II 1/ G EEx ia/ib IIB/IIC T4, T5, T6 Permissible ambient temperature Temperature class T C ( F) Temperature class T C ( F) Temperature class T C ( F) Connection To certified intrinsically-safe circuits with maximum values: To certified intrinsically-safe circuits with maximum values: U i = 30 V, I i = 100 ma, P i = 750 mw, R i = 300 Ω FISCO supply unit: U i = 17.5 V, I i = 380 ma, P i = 5.3 W Linear barrier: U i = 4 V, I i = 50 ma, P i = 1. W Effective inner capacitance: C i = 6 nf C i = 1.1 nf Effective inner inductance: L i = 0.4 mh L i 7 µh Explosion protection to FM for USA and Canada (cfmus) Identification (DIP) or (IS); (NI) Certificate of Compliance CL I, DIV 1, GP ABCD T4... T6; CL II, DIV 1, GP EFG; CL III; CL I, ZN 0/1 AEx ia IIC T4... T6; CL I, DIV, GP ABCD T4... T6; CL II, DIV, GP FG; CL III Identification (DIP) or (IS) Certificate of Compliance C CL I, DIV 1, GP ABCD T4... T6; CL II, DIV 1, GP EFG; CL III; Ex ia IIC 4... T6; CL I, DIV, GP ABCD T4... T6; CL II, DIV, GP FG; CL III Siemens FI US Edition /7

28 Transmitters for gage and absolute pressure SITRANS P300 Siemens AG 007 HART communication HART communication Ω Protocol HART Version 5.x Software for computer SIMATIC PDM PROFIBUS PA communication Simultaneous communication with master class (max.) The address can be set using Cyclic data usage Output byte Input byte Internal preprocessing Device profile Function blocks Analog input - Adaptation to customer-specific process variables - Electrical damping T 63, adjustable 4 Configuration tool or local operation (standard setting address 16) 5 (one measuring value) or 10 (two measuring values) 0, 1, or (register operating mode and reset function for metering) PROFIBUS PA Profile for Process Control Devices Version 3.0, Class B Yes, linearly rising or falling characteristic s - Simulation function Input /Output - Failure mode Can be parameterized (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively Register (totalizer) Can be reset, preset, optional direction of counting, simulation function of register output - Failure mode Can be parameterized (summation with last good value, continuous summation, summation with incorrect value) - Limit monitoring One upper and lower warning limit and one alarm limit respectively Physical block 1 Transducer blocks Pressure transducer block - Monitoring of sensor limits Yes - Characterizer Max. 30 points - Transfer function Linear - Simulation function Available Transducer block Electronic temperature - Simulation function Available Communication FOUNDATION Fieldbus Function blocks 3 function blocks analog input, 1 function block PID Analog input - Adaptation to customer-specific process variables - Electrical damping T 63, adjustable Yes, linearly rising or falling characteristic s - Simulation function Output/input (can be locked within the device with a bridge) - Failure mode Can be parameterized (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively - Square-rooted characteristic Yes for flow measurement PID Standard FF function block Physical block 1 Resource block Transducer blocks 1 transducer block Pressure with calibration, 1 transducer block LCD Pressure transducer block - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Simulation function: Measured pressure value, sensor temperature and electronics temperature Constant value or over parameterizable ramp function /8 Siemens FI US Edition

29 Siemens AG 007 Transmitters for gage and absolute pressure SITRANS P300 Selection and Ordering data Order No. SITRANS P300 pressure transmitters for gage and absolute pressure, single-chamber measuring housing, rating plate inscription in English ma/hart 7 M F PROFIBUS PA 7 M F FOUNDATION Fieldbus (FF) 7 M F Measuring cell filling Measuring cell cleaning Silicone oil Standard 1 Inert liquid Cleanliness level to 3 DIN 5410 max. span 1 bar g (14.5 psi g) B 4 bar g (58 psi g) C 16 bar g (3 psi g) D 63 bar g (914 psi g) E 160 bar g (30 psi g) F 400 bar g (5800 psi g) G 0.5 bar a (3.63 psi a) F) Q 1.3 bar a (18.9 psi a) F) S 5 bar a (7.5 psi a) F) T 30 bar a (435 psi a) F) U Wetted parts materials Seal diaphragm Measuring cell Stainless steel Stainless steel A Hastelloy Stainless steel F) B Hastelloy Hastelloy F) C 1) ) Version for diaphragm seal Y Process connection G½A to EN ½-14 NPT 1 Oval flange made of stainless steel - Mounting thread 7 / 16-0 UNF to EN Mounting thread M10 to DIN Mounting thread M1 to DIN Male thread M0 x 1,5 5 Male thread ½ -14 NPT 6 Non-wetted parts materials St. steel, deep-drawn and electrolytically polished 4 Version Standard version 1 Explosion protection Without A With ATEX, Type of protection: - "Intrinsic safety (EEx ia)" B With FM Intrinsic safe (cfm US ) M Electrical connection / cable entry Screwed gland M0x1.5 (Polyamide) 3) A Screwed gland M0x1.5 (metal) B Screwed gland M0x1.5 (stainless steel) C M1 connector (metal, without cable socket) F M1 connector (stainless steel, without cable socket) G ½-14 NPT thread, metal 4) H ½-14 NPT thread, stainless steel 4) J Selection and Ordering data Order No. SITRANS P300 pressure transmitters for gage and absolute pressure, single-chamber measuring housing, rating plate inscription in English ma/hart 7 M F PROFIBUS PA 7 M F FOUNDATION Fieldbus (FF) 7 M F Display Without display, with keys, closed lid 3) 1 With display and keys, closed lid With display and keys, lid with glass pane 6 (setting on HART devices: ma, on PROFIBUS devices: pressure units) With display (setting acc. to specifications, Order 7 code "Y1" or "Y" required), lid with glass pane Power supply units see "SITRANS I power supply units and isol. amplifiers". Factory-mounting of shut-off valves and valve manifolds see page /16. Included in delivery of the device: Brief instructions (Leporello) CD-ROM with detailed documentation 1) ) 3) 4) When the manufacture s certificate M (calibration certificate) has to be ordered for transmitters with diaphragm seals, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. Whe the acceptance test certificate 3.1 for transmitters with direct-connected diaphragm seals is ordered, this certificate must also be ordered with the corresponding seals. Only together with HART electronics. Without cable gland. F) Subject to export regulations AL: 9I999, ECCN: N. Siemens FI US Edition /9

30 Transmitters for gage and absolute pressure SITRANS P300 Siemens AG 007 Selection and Ordering data 1) Only together with HART electronics. ) Without cable gland. F) Subject to export regulations AL: 9I999, ECCN: N. Order No. SITRANS P300 pressure transmitters for gage pressure with front-flush membrane, single-chamber measuring housing, rating plate inscription in English ma/hart F) 7 M F PROFIBUS PA F) 7 M F FOUNDATION Fieldbus (FF) F) 7 M F Measuring cell filling Measuring cell cleaning Silicone oil Standard 1 Inert liquid Cleanliness level to 3 DIN 5410 FDA compliant fill fluid Neobee oil Standard 4 max. span 1 bar g (14.5 psi g) B 4 bar g (58 psi g) C 16 bar g (3 psi g) D 63 bar g (914 psi g) E Wetted parts materials Seal diaphragm Measuring cell Stainless steel Stainless steel A Process connection Flange version with Order code M.., N.., R.. or Q.. 7 (see "Further designs") Non-wetted parts materials Stainless steel, deep-drawn and electrolytically 4 polished Version Standard version 1 Explosion protection Without A With ATEX, Type of protection: - "Intrinsic safety (EEx ia)" B With FM Intrinsic safe (cfm US ) M Electrical connection / cable entry Screwed gland M0x1.5 (Polyamide) 1) A Screwed gland M0x1.5 (metal) B Screwed gland M0x1.5 (stainless steel) C M1 connector (without cable socket) F M1 connector (stainless steel, without cable socket) G ½-14 NPT thread, metal ) H ½-14 NPT thread, stainless steel ) J Display Without display, with keys, closed lid 1) 1 With display and keys, closed lid With display and keys, lid with macrolon washer 4 (setting on HART devices: ma, on PROFIBUS PA and FOUNDATION Fieldbus devices: pressure units) With display (setting acc. to specifications, Order 5 code "Y1" or "Y" required), lid with macrolon washer With display and keys, lid with glass pane 6 (setting on HART devices: ma, on PROFIBUS PA and FOUNDATION Fieldbus devices: pressure units) With display (setting acc. to specifications, Order 7 code "Y1" or "Y" required), lid with glass pane Power supply units see "SITRANS I power supply units and isol. amplifiers". Included in delivery of the device: Brief instructions (Leporello) CD-ROM with detailed documentation Selection and Ordering data Order code Further designs Add "-Z" to Order No. and specify Order code. HART PA FF Mounting bracket A0 made completely of stainless steel, for wall or pipe mounting Cable socket for M1 plug Metal A50 Stainless steel A51 Rating plate inscription (instead of English) German B10 French B1 Spanish B13 Italian B14 English rating plate B1 Pressure units in inh O or psi Manufacturer's test certificate M 1) C11 (calibration certificate) to DIN 55350, Part 18 and to ISO 840 Acceptance test certificate ) C1 to EN Factory certificate C14 to EN Type of protection IP68 D1 Only for SITRANS P300 with front-flush diaphragm (7MF ) Flange to EN DN 5, PN 40 M11 DN 5, PN 100 M1 DN 40, PN 40 M13 DN 40, PN 100 M3 DN 50, PN 16 M04 DN 50, PN 40 M14 DN 80, PN 5 M06 DN 80, PN 40 M16 Flanges to ASME B16.5 1", class 150 M40 1½", class 150 M41 ", class 150 M4 3", class 150 M43 4", class 150 M44 1", class 300 M45 1½", class 300 M46 ", class 300 M47 3", class 300 M48 Threaded connection G, flush-mounted R04 Tank connection TG 5/50, PN 40 R10 Sanitary process connection according DIN (Dairy connection) DN 50, PN 5 N04 DN 80, PN 5 N06 Tri-Clamp connection according DIN 3676/ISO 85 certified to 3A 3) DN 50/, PN 16 N14 DN 65/3, PN 10 N15 Varivent connection certified to 3A and EHEDG 3) Type N = 68 for Varivent housing N8 DN and 1½"... 6", PN 40 Temperature decoupler up to 00 C 3) for version with front-flush diaphragm P00 /30 Siemens FI US Edition

31 Siemens AG 007 Transmitters for gage and absolute pressure SITRANS P300 Selection and Ordering data Further designs Add "-Z" to Order No. and specify Order code. Bio-Control (Neumo) sanitary connection certified to 3A and EHEDG 3) DN 50, PN 16 Q53 DN 65, PN 16 Q54 Sanitary process connection to DRD 50 mm, PN 40 M3 Sanitary process connection to NEUMO Bio-Connect screw connection certified to 3A and EHEDG 3) DN 40, PN 16 Q04 DN 50, PN 16 Q05 DN 65, PN 16 Q06 DN 80, PN 16 Q07 DN 100, PN 16 Q08 DN, PN 16 Q13 DN ½, PN 16 Q14 DN 3, PN 16 Q15 DN 4, PN 16 Q16 Sanitary process connection to NEUMO Bio-Connect flange connection certified to 3A and EHEDG 3) DN 50, PN 16 Q3 DN 65, PN 16 Q4 DN 80, PN 16 Q5 DN 100, PN 16 Q6 DN, PN 16 Q31 DN ½, PN 16 Q3 DN 3, PN 16 Q33 DN 4, PN 16 Q34 Sanitary process connection to NEUMO Bio-Connect clamp connection certified to 3A and EHEDG 3) DN 50, PN 16 Q39 DN 65, PN 10 Q40 DN 80, PN 10 Q41 DN 100, PN 10 Q4 DN ½, PN 16 Q48 DN 3, PN 10 Q49 DN 4, PN 10 Q50 Sanitary process connection to NEUMO Connect S flange connection certified to 3A and EHEDG DN 50, PN 16 Q63 DN 65, PN 10 Q64 DN 80, PN 10 Q65 DN 100, PN 10 Q66 DN, PN 16 Q7 DN ½, PN 10 Q73 DN 3, PN 10 Q74 DN 4, PN 10 Q75 1) ) 3) Order code HART PA FF When the manufacture s certificate M (calibration certificate) has to be ordered for transmitters with diaphragm seals, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. Whe the acceptance test certificate 3.1 for transmitters with direct-connected diaphragm seals is ordered, this certificate must also be ordered with the corresponding seals. Certified to 3A. The maximum temperatures of the medium depend on the respective cell fillings. Selection and Ordering data Order code Additional data Add "-Z" to Order No. and specify Order code. HART PA FF Measuring range to be set Y01 Specify in plain text V (max. 5 digits): Y01:... up to... mbar, bar, kpa, MPa, psi Measuring point number (TAG No.) Y15 Max. 16 characters, specify in plain text: Y15:... Measuring point text Y16 Max. 7 characters, specify in plain text: Y16:... Entry of HART TAG Y17 Max. 8 characters, specify in plain text: Y17:... Setting of pressure indication in pressure Y1 units Specify in plain text (standard setting: ma): Y1: mbar, bar, kpa, MPa, psi,... Note: The following pressure units can be selected: bar, mbar, mm H O *), inh O *), fth O *), mmhg, inhg, psi, Pa, kpa, MPa, g/cm, kg/cm, Torr, ATM or % *) ref. temperature 0 C Setting of pressure indicator in Y + non-pressure units Y01 Specify in plain text: Y:... up to... l, m 3, m, USg,... (specification of measuring range in pressure units "Y01" is essential, unit with max. 5 characters) Preset bus address Y5 Specify in plain text: Y5:... Only "Y01" and "Y1" can be factory preset = available Ordering example Item line: 7MF803-1DB4-1AB7-Z B line: A0 + Y01 + Y1 C line: Y01: bar ( psi) C line: Y1: bar (psi) Siemens FI US Edition /31

32 Transmitters for gage and absolute pressure SITRANS P300 Siemens AG 007 Dimensional drawings SITRANS P300, with oval flange, dimensions in mm (inch) SITRANS P300 with mounted mounting bracket, dimensions in mm (inch) /3 Siemens FI US Edition

33 Siemens AG 007 Transmitters for gage and absolute pressure SITRANS P300 SITRANS P300, front-flush, dimensions in mm (inch) The diagram shows a SITRANS P300 with an example of a flange. In this drawing the height is subdivided into H 1 and H. H 1 = Height of the SITRANS P300 up to a defined cross-section H = Height of the flange up to this defined cross-section Only the height H is indicated in the dimensions of the flanges. Flanges to EN and ASME Flanges to EN EN Flanges to ASME ASME B16.5 DN PN D H mm (4.5 ) Approx mm (5.5 ) 5 mm ( ) mm (5.9 ) mm (6.7 ) mm (6.5 ) mm (6.5 ) mm (7.9 ) mm (7.9 ) DN class D H mm (4.3 ) Approx mm (4.9 ) 5 mm ( ) 1½ mm (5.1 ) 1½ mm (6.1 ) mm (5.9 ) mm (6.5 ) mm (7.5 ) mm (8.1 ) mm (9.1 ) mm (10.0 ) NuG and pharmaceutical connections Connections to DIN DIN (Dairy connection) DN PN D H mm (3.6 ) Approx mm (5.0 ) 5 mm ( ) Tri-Clamp according DIN 3676 DN PN D H mm (.5 ) Approx mm (3.6 ) 5 mm ( ) Other connections Varivent connection DN PN D H mm (3.3 ) Approx. 5 mm ( ) Siemens FI US Edition /33

34 Transmitters for gage and absolute pressure SITRANS P300 Siemens AG 007 Bio-Control connection Sanitary process connection to DRD DN PN D H mm (3.5 ) Approx mm (4.7 ) 5 mm ( ) DN PN D H mm (4.1 ) Approx. 5 mm ( ) Sanitary process screw connection to NEUMO Bio-Connect DN PN D H mm (3. ) Approx mm (4.1 ) 5 mm ( ) mm (4.5 ) mm (5.7 ) 16 8 mm (3. ) ½ mm (4.1 ) mm (4.1 ) mm (5.7 ) Sanitary connection to NEUMO Bio-Connect S flange connection DN PN D H mm (4.9 ) Approx mm (5.7 ) 5 mm ( ) mm (6.1 ) mm (7.1 ) mm (4.9 ) ½ mm (5.3 ) mm (5.7 ) mm (7.1 ) Thread connection G to DIN 385 DN PN D H mm (3.1 ) Approx. 5 mm ( ) Tank connection TG 5/50 DN PN D H mm (.5 ) Approx. 63 mm (.5 ) Sanitary connection to NEUMO Bio-Connect flange connection DN PN D H mm (4.3 ) Approx mm (5.5 ) 5 mm ( ) mm (5.9 ) mm (6.9 ) mm (3.9 ) ½ mm (4.3 ) mm (5.5 ) mm (6.9 ) Sanitary connection to NEUMO Bio-Connect clamp connection DN PN D H ,4 mm (3.0 ) Approx ,9 mm (3.6 ) 5 mm ( ) mm (4. ) mm (4.7 ) mm (.5 ) ½ 16 77,4 mm (3.0 ) ,9 mm (3.6 ) mm (4.7 ) /34 Siemens FI US Edition

35 Overview Siemens AG 007 Transmitters for gage pressure for the paper industry SITRANS P300 and DS III series with PMC connection Technical description Small long-term drift Wetted parts made of Hastelloy Infinitely adjustable spans from 30 mbar g to 16 bar g (0.15 psi g to 0.3 psi g) for DS III with HART interface Nominal measuring range from 1 bar g to 16 bar g (14.5 psi g to 3 psi g) for DS III with PROFIBUS PA and FOUNDATION Fieldbus interface Infinitely adjustable spans from 30 mbar g to 16 bar g (0.15 psi g to 0.3 psi g) for SITRANS P300 with HART interface Nominal measuring range from 1 bar g to 16 bar g (14.5 psi g to 3 psi g) for SITRANS P300 with PROFIBUS PA interface High measuring accuracy Parameterization over control keys and HART communication, or over PROFIBUS PA or FOUNDATION Fieldbus interface (DS III only). The SITRANS P300 and DS III pressure transmitters have been fitted with special process connections for the paper industry. With the two process connection threads 1½" and 1" flush at the front, the SITRANS P300 and DS III transmitters can be used for all processes in the paper industry. SITRANS P300 and DS III series pressure transmitters are digital pressure transmitters featuring extensive user-friendliness and high accuracy. The parameterization is performed using control keys, over HART communication, PROFIBUS PA or FOUNDATION Fieldbus interface (DS III only). Extensive functionality enables the pressure transmitter to be precisely adapted to the plant s requirements. Operation is very simple in spite of the numerous setting options. Transmitters with type of protection "Intrinsic safety" and "Explosion-proof" may be installed within potentially explosive atmospheres (zone 1) or in zone 0. The transmitters are provided with an EC type examination certificate and comply with the corresponding harmonized European standards (ATEX). Various versions of the pressure transmitters are available for measuring: Gage pressure Filling level Volume level Mass level Benefits High quality and long life High reliability even under extreme chemical and mechanical loads, e.g. abrasion. For aggressive and non-aggressive gases, vapors and liquids Extensive diagnosis and simulation functions Minimum conformity error Application The pressure transmitters of the DS III series, can be used in industrial areas with extreme chemical and mechanical loads. Electromagnetic compatibility in the range 10 khz to 1 GHz makes the DS III pressure transmitters suitable for locations with high electromagnetic emissions. Pressure transmitters with type of protection "Intrinsic safety" and "Explosion-proof" may be installed within potentially explosive atmospheres (zone 1) or in zone 0. The pressure transmitters are provided with an EC type examination certificate and comply with the corresponding harmonized European standards (ATEX). Pressure transmitters with the type of protection "Intrinsic safety" for use in zone 0 may be operated with power supply units of category "ia" and "ib". The transmitters can be equipped with various designs of remote seals for special applications such as the measurement of highly viscous substances. The pressure transmitter can be operated locally over 3 control keys or programmed externally over HART communication or over PROFIBUS PA or FOUNDATION Fieldbus interface (only DS III). SITRANS P, DS III series Measured variable: Gage pressure of aggressive and nonaggressive gases, vapors and liquids. Span (infinitely adjustable) For DS III HART: bar g ( psi g) Nominal measuring range For DS III PA and FF: bar g ( psi g) SITRANS P300 Span (infinitely adjustable) For DS III HART: bar g ( psi g) Nominal measuring range For DS III PA: bar g ( psi g) Siemens FI US Edition /35

36 Transmitters for gage pressure for the paper industry SITRANS P300 and DS III series with PMC connection Technical description Design SITRANS P, DS III series Siemens AG 007 SITRANS P300 The device comprises: Electronics Housing Measuring cell Device front view, SITRANS P DS III The transmitter comprises a range of different components, depending on the order specifications. The various options are listed in the ordering information. The components described below are the same for all transmitters. The rating plate (3, Figure "Front view") with the Order No. is located on the side of the housing. The specified number together with the ordering information provide details on the optional design details and on the possible measuring range (physical properties of built-in sensor element). The approval label is located on the opposite side. The housing is made of die-cast aluminium or stainless steel precision casting. A round cover is screwed on at the front and rear of the housing. The front cover (6) can be fitted with a viewing pane so that the measured values can be read directly on the digital display. The inlet (4) for the electrical connection is located either on the left or right side. The unused opening on the opposite side is sealed by a blanking plug. The protective earth connection is located on the rear of the housing. The electrical connections for the power supply and screen are accessible by unscrewing the rear cover. The bottom part of the housing contains the measuring cell with process connection (1). The measuring cell is prevented from rotating by a locking screw (8). As the result of this modular design, the measuring cell and the electronics can be replaced separately from each other. The set parameter data are retained. At the top of the housing is a plastic cover (5), which hides the input keys. Perspective view of the SITRANS P300 The housing has a screwable cover (3), with or without an inspection window depending on the version. The electrical terminal housing, the buttons for operation of the device and, depending on the version, the digital display are located under this cover. The connections for the auxiliary power U H and the shield are in the terminal housing. The cable gland is on the side of the housing. The measuring cell with the process connection (5) is located on the underside of the housing. Depending on the version of the device, the measuring cell with the process connection may differ from the one shown in the diagram. /36 Siemens FI US Edition

37 Function Mode of operation of the DS III HART electronics 1 Sensor 8 M 3 EEPROM 6 4 mc HART interface EEPROM 6 Electronics Transmitters for gage pressure for the paper industry SITRANS P300 and DS III series with PMC connection Technical description 10 Siemens AG 007 I A, U H Mode of operation of the DS III PA electronics 1 Sensor p e 8 M mc PA interface EEPROM Measuring cell EEPROM 6 Electronics PROFIBUS-PA Power supply 10 Power supply unit Coupler 11 1 PROFIBUS-DP Bus- Master P e Measuring cell 1 Measuring cell sensor Instrument amplifier 3 Analog-to-digital converter 4 Microcontroller 5 Digital-to-analog converter 6 One non-volatile memory each in the measuring cell and electronics 7 HART interface 8 Three input keys (local operation) 9 Digital display 10 Diode circuit and connection for external ammeter I A Output current U H Power supply P e Input variable Function diagram of electronics The bridge output voltage created by the sensor (1, Figure "Function diagram of electronics") is amplified by the instrument amplifier () and digitized in the analog-to-digital converter (3). The digital information is evaluated in a microcontroller, its linearity and temperature response corrected, and converted in a digital-to-analog converter (5) into an output current of 4 to 0 ma. The diode circuit (10) protects against incorrect polarity. The data specific to the measuring cell, the electronics data, and the parameter data are stored in the two non-volatile memories (6). The one memory is coupled to the measuring cell, the other to the electronics. As the result of this modular design, the electronics and the measuring cell can be replaced separately from each other. Using the 3 input keys (8) you can parameterize the pressure transmitter directly at the point of measurement. The input keys can also be used to control the view of the results, the error messages and the operating modes on the digital display (9). The HART modem (7) permits parameterization using a protocol according to the HART specification. The pressure transmitters with spans 63 bar g measure the input pressure compared to atmosphere, transmitters with spans 160 bar g compared to vacuum. 1 Measuring cell sensor Instrument amplifier 3 Analog-to-digital converter 4 Microcontroller 5 Electrical isolation 6 One non-volatile memory each in the measuring cell and electronics 7 PROFIBUS-PA interface 8 Three input keys (local operation) 9 Digital display 10 Power supply 11 DP/PA coupler or link 1 Bus master Function diagram of electronics The bridge output voltage created by the sensor (1, Figure "Function diagram of electronics") is amplified by the instrument amplifier () and digitized in the analog-to-digital converter (3). The digital information is evaluated in the microcontroller, its linearity and temperature response corrected, and provided on the PROFIBUS PA through an electrically isolated PA interface (7). The data specific to the measuring cell, the electronics data, and the parameter data are stored in the two non-volatile memories (6). The first memory is linked with the measuring cell, the second with the electronics. This modular design means that the electronics and the measuring cell can be replaced separately from one another. Using the three input keys (8) you can parameterize the pressure transmitter directly at the point of measurement. The input keys can also be used to control the view of the results, the error messages and the operating modes on the digital display (9). The results with status values and diagnostic values are transferred by cyclic data transmission on the PROFIBUS PA. Parameterization data and error messages are transferred by acyclic data transmission. Special software such as SIMATIC PDM is required for this. p e Input variable Siemens FI US Edition /37

38 Transmitters for gage pressure for the paper industry SITRANS P300 and DS III series with PMC connection Technical description Mode of operation of the DS III FF electronics 8 M Siemens AG 007 Mode of operation of the measuring cell Measuring cell for gage pressure with front-flush diaphragm 1 Sensor p e mc FF interface EEPROM 6 Measuring cell EEPROM 1 Measuring cell sensor Instrument amplifier 3 Analog-to-digital converter 4 Microcontroller 5 Electrical isolation 6 One non-volatile memory each in the measuring cell and electronics 7 FF interface 6 Electronics Power supply 10 Power supply unit Coupler 8 Three input keys (local operation) 9 Digital display 10 Power supply p e Input variable p e 1 1 Measuring cell Process connection 3 Seal diaphragm 4 Filling liquid 5 Silicon pressure sensor p e Pressure as input variable Measuring cell for gage pressure, with front-flush diaphragm, function diagram The pressure p e is applied through the process connection (, Figure "Measuring cell for gage pressure, with front-flush diaphragm for paper industry, function diagram") to the measuring cell (1). This pressure is subsequently transmitted further through the seal diaphragm (3) and the filling liquid (4) to the silicon pressure sensor (5) whose measuring diaphragm is then flexed. This changes the resistance of the four piezo-resistors fitted in the diaphragm in a bridge circuit. This change in resistance results in a bridge output voltage proportional to the input pressure. Function diagram of electronics The bridge output voltage created by the sensor (1, Figure "Function diagram of electronics") is amplified by the instrument amplifier () and digitized in the analog-to-digital converter (3). The digital information is evaluated in the microcontroller, its linearity and temperature response corrected, and provided on the FOUNDATION Fieldbus through an electrically isolated FOUNDATION Fieldbus Interface (7). The data specific to the measuring cell, the electronics data, and the parameter data are stored in the two non-volatile memories (6). The one memory is coupled to the measuring cell, the other to the electronics. As the result of this modular design, the electronics and the measuring cell can be replaced separately from each other. Using the three input keys (8) you can parameterize the pressure transmitter directly at the point of measurement. The input keys can also be used to control the view of the results, the error messages and the operating modes on the digital display (9). The results with status values and diagnostic values are transferred by cyclic data transmission on the FOUNDATION Fieldbus. Parameterization data and error messages are transferred by acyclic data transmission. Special software such as National Instruments Configurator is required for this. Parameterization Depending on the version, there are a range of options for parameterizing the pressure transmitter and for setting or scanning the parameters. Parameterization using the input keys (local operation) With the input keys you can easily set the most important parameters without any additional equipment. Parameterization using HART communication Parameterization using HART communication is performed with a HART communicator or a PC. SITRANS P transmitter HART communicator W Communication between a HART communicator and a pressure transmitter When parameterizing with the HART communicator, the connection is made directly to the -wire system. + Power supply /38 Siemens FI US Edition

39 Siemens AG 007 Transmitters for gage pressure for the paper industry SITRANS P300 and DS III series with PMC connection Technical description HART communication between a PC communicator and a pressure transmitter When parameterizing with a PC, the connection is made through a HART modem. The signals needed for communication in conformity with the HART 5.x or 6.x protocols are superimposed on the output current using the Frequency Shift Keying (FSK) method. Adjustable parameter DS III HART and P300 HART Parameters Pushbuttons HART communication Start of scale x x Full-scale value x x Electrical damping x x Start-of-scale value without application x x of a pressure ("Blind setting") Full-scale value without application of a x x pressure ("Blind setting") Zero adjustment x x Current transmitter x x Fault current x x Disabling of keys, write protection x x 1) Type of dimension and actual dimension x x Characteristic (linear) x x Input of characteristic x Freely-programmable LCD x Diagnostics functions x 1) SITRANS P transmitter HART modem PC or laptop RS W Power supply Cancel apart from write protection Diagnostic functions for DS III HART and P300 HART Zero correction display Event counter Limit transmitter Saturation alarm Min/Max registers Simulation functions Maintenance timer Available physical units of display for DS III HART and P300 HART Physical variable Physical dimensions Pressure (setting can also be Pa, MPa, kpa, bar, mbar, torr, atm, made in the factory) psi, g/cm, kg/cm, inh O, inh O (4 C), mmh O, fth O (0 C), inhg, mmhg Level (height data) m, cm, mm, ft, in Volume m 3, dm 3, hl, yd 3, ft 3, in 3, US gallon, lmp, gallon, bushel, barrel, barrel liquid Mass g, kg, t, lb, Ston, Lton, oz Temperature K, C, F, R Miscellaneous %, ma Parameterization through PROFIBUS PA interface Fully digital communication through PROFIBUS PA, profile 3.0, is particularly user-friendly. The PROFIBUS puts the DS III PA is in connection with a process control system, e.g. SIMATIC PSC 7. Communication is possible even in a potentially explosive environment. For parameterization through PROFIBUS you need suitable software, e.g. SIMATIC PDM (Process Device Manager). Parameterization through FOUNDATION Fieldbus Interface Fully digital communication through FOUNDATION Fieldbus is particularly user-friendly. Through the FOUNDATION Fieldbus the DS III FF is connected to a process control system. Communication is possible even in a potentially explosive environment. For parameterization through the FOUNDATION Fieldbus you need suitable software, e.g. National Instruments Configurator. Adjustable parameters for DS III PA and FF and P300 PA and FF Adjustable parameters Pushbuttons PROFIBUS PA and FOUNDATION Fieldbus interface Electrical damping x x Zero adjustment (correction of x x position) Key and/or function disabling x x Source of measured-value display x x Physical dimension of display x x Position of decimal point x x Bus address x x Adjustment of characteristic x x Input of characteristic x Freely-programmable LCD x Diagnostic functions x Diagnostic functions for DS III PA and FF and P300 PA Event counter Min/Max registers Maintenance timer Simulation functions Display of zero correction Limit transmitter Saturation alarm Physical dimensions available for the display Physical variable Physical dimensions Pressure (setting can also be MPa, kpa, Pa, bar, mbar, torr, atm, made in the factory) psi, g/cm, kg/cm, mmh O, mmh O (4 C), inh O, inh O (4 C), fth O (0 C), mmhg, inhg Level (height data) m, cm, mm, ft, in, yd Mass g, kg, t, lb, Ston, Lton, oz Volume m 3, dm 3, hl, yd 3, ft 3, in 3, US gallon, lmp, gallon, bushel, barrel, barrel liquid Temperature K, C, F, R Miscellaneous % Siemens FI US Edition /39

40 Transmitters for gage pressure for the paper industry DS III series with PMC connection Siemens AG 007 Technical specifications SITRANS P, DS III series for gage pressure with PMC connection for the paper industry Input Measured variable Spans (infinitely adjustable) or nominal measuring range and max. permissible test pressure HART Gage pressure Span bar g ( psi g) bar g ( psi g) bar g ( psi g) Max. perm. test pressure 6 bar g (87 psi g) 10 bar g (145 psi g) 3 bar g (464 psi g) PROFIBUS PA or FOUNDATION Fieldbus Nominal measuring range 1 bar g (14.5 psi g) 4 bar g (58 psi g) 16 bar g (3 psi g) Max. perm. test pressure 6 bar g (87 psi g) 10 bar g (145 psi g) 3 bar g (464 psi g) Lower measuring limit Measuring cell with silicone oil filling 100 mbar a (1.45 psi a) Upper measuring limit 100% of max. span Output Output signal ma Digital PROFIBUS PA or FOUNDATION Fieldbus signal Lower limit (infinitely adjustable) 3.55 ma, factory preset to 3.84 ma - Upper limit (infinitely adjustable) 3 ma, factory preset to 0.5 ma or optionally set - to.0 ma Load Without HART communication R B (U H V)/0.03 A in Ω, - U H : Power supply in V With HART communication R B = Ω (SIMATIC PDM) or - R B = Ω (HART Communicator) Physical bus - IEC With polarity reversal protection - Yes Accuracy To EN Reference conditions Increasing characteristic, start-of-scale value 0 bar, stainless steel seal diaphragm, silicone oil filling, room temperature 5 C (77 F)) r: Span ratio (r = max. span/set span) Error in measurement and fixed-point setting (including hysteresis and repeatability) Linear characteristic 0,075% -r 10 (0.009 r )% - 10 < r 30 ( r )% - 30 < r 100 (0.005 r )% Long-term drift (temperature change ± 30 C (0.5 r)% every 5 years 0.5% every 5 years (± 54 F)) Influence of ambient temperature at C ( F) (0.08 r + 0.1)% 0,3% at C and C (0.1 r )%/10 K 0.5%/10 K ( F and F) Influence of medium temperature Temperature difference between medium 3 mbar/10 K (0.04 psi/10 K) temperature and ambient temperature Influence of mounting position 0.1 mbar g ( psi g) per 10 inclination Measured Value Resolution of nominal measuring range /40 Siemens FI US Edition

41 Siemens AG 007 Transmitters for gage pressure for the paper industry DS III series with PMC connection SITRANS P, DS III series for gage pressure with PMC connection for the paper industry HART Rated operating conditions Degree of protection (to EN 6059) IP65 Process temperature C ( F) Ambient conditions Ambient temperature C ( F) Storage temperature C ( F) Climatic class - Condensation Permissible Electromagnetic compatibility - Emitted interference and interference immunity To EN 6136 and NAMUR NE 1 Design Weight (without options) 1.5 kg ( 3.3 lb) Housing material Low copper die-cast aluminium, GD-AlSi1 Wetted parts materials Stainless steel Gasket (standard) PTFE flat gasket O-ring (minibolt) FPM (Viton) or optionally: FFPM or NBR Measuring cell filling Silicone oil or inert filling liquid Process connection (standard) Front-flush, 1½", PMC Standard design Process connection (minibolt) Front-flush, 1", minibolt design Power supply U H Supplied through bus Terminal voltage on transmitter V DC V DC in intrinsically-safe mode Separate 4 V power supply necessary - No Bus voltage Not Ex V With intrinsically-safe operation V Current consumption Basic current (max.) ma Startup current basic current - Yes Max. current in event of fault ma Fault disconnection electronics (FDE) available - Yes Certificate and approvals Classification according to pressure equipment directive (DRGL 97/3/EC) PROFIBUS PA or FOUNDATION Fieldbus For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of Article 3, paragraph 3 (sound engineering practice) Siemens FI US Edition /41

42 Transmitters for gage pressure for the paper industry DS III series with PMC connection Siemens AG 007 SITRANS P, DS III series for gage pressure with PMC connection for the paper industry HART communication HART communication Ω Protocol HART Version 5.x Software for computer SIMATIC PDM PROFIBUS PA communication Simultaneous communication with master class (max.) The address can be set using Cyclic data usage Output byte Input byte Internal preprocessing Device profile Function blocks Analog input - Adaptation to customer-specific process variables - Electrical damping T 63, adjustable 4 Configuration tool or local operation (standard setting address 16) 5 (one measuring value) or 10 (two measuring values) 0, 1, or (register operating mode and reset function for metering) PROFIBUS PA Profile for Process Control Devices Version 3.0, Class B Yes, linearly rising or falling characteristic s - Simulation function Input /Output - Failure mode Can be parameterized (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively Register (totalizer) Can be reset, preset, optional direction of counting, simulation function of register output - Failure mode Can be parameterized (summation with last good value, continuous summation, summation with incorrect value) - Limit monitoring One upper and lower warning limit and one alarm limit respectively Physical block 1 Transducer blocks Pressure transducer block - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Characterizer Max. 30 points - Simulation function for measured pressure value and sensor temperature Constant value or over parameterizable ramp function Communication FOUNDATION Fieldbus Function blocks 3 function blocks analog input, 1 function block PID Analog input - Adaptation to customer-specific process variables - Electrical damping T 63, adjustable Yes, linearly rising or falling characteristic s - Simulation function Output/input (can be locked within the device with a bridge) - Failure mode Can be parameterized (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively - Square-rooted characteristic Yes for flow measurement PID Standard FF function block Physical block 1 Resource block Transducer blocks 1 transducer block Pressure with calibration, 1 transducer block LCD Pressure transducer block - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Simulation function: Measured pressure value, sensor temperature and electronics temperature Constant value or over parameterizable ramp function /4 Siemens FI US Edition

43 Siemens AG 007 Transmitters for gage pressure for the paper industry DS III series with PMC connection Selection and Ordering data SITRANS P pressure transmitters for gage pressure, with PMC connection series DS III HART Measuring cell filling Measuring cell cleaning Order No. F) 7 M F Silicone oil Standard 1 Inert liquid Grease-free 3 Span bar g 1) ( psi g) 1) B bar g ( psi g) C bar g ( psi g) D Wetted parts materials Seal diaphragm Connection shank Hastelloy Stainless steel B Process connection PMC Style Standard: Thread 1½" PMC Style Mini bolt: 1" front-flush 3 (not with span - version "B") Non-wetted parts materials Housing made of die-cast aluminum 0 Housing stainless steel precision casting 3 Version Standard version 1 International version, English label inscriptions, documentation in 5 languages on CD Explosion protection None A FM/CSA Explosion proof N Electrical connection / cable entry Female thread M0x1.5 B Female thread ½-14 NPT C M1 connectors (metal) F Display Without (digital indicator hidden, setting: ma) 1 With visible digital indication, setting: ma 6 With customer-specific digital indication (setting 7 as specified, Order code "Y1" or "Y" required) Power supply units see "SITRANS I power supply units and isolation amplifiers". Included in delivery of the device: Brief instructions (Leporello) CD-ROM with detailed documentation Sealing ring 1) Only with "PMC Style Standard" process connection Selection and Ordering data Order No. SITRANS P pressure transmitter for gage pressure, with PMC connection DS III PA (PROFIBUS PA) series F) 7 M F DS III FF series (FOUNDATION Fieldbus) F) 7 M F Measuring cell filling Measuring cell cleaning Silicone oil Standard 1 Inert liquid Grease-free 3 Nominal measuring range 1bar g 1) (14.5 psi g) 1) B 4 bar g (58 psi g) C 16 bar g (3 psi g) D Wetted parts materials Seal diaphragm Connection shank Hastelloy Stainless steel B Process connection PMC Style Standard: front-flush 1½" PMC Style Mini bolt: front-flush 1" 3 (not with span - version "B") Non-wetted parts materials Housing made of die-cast aluminum 0 Housing stainless steel precision casting 3 Version Standard version 1 International version, English label inscriptions, documentation in 5 languages on CD Explosion protection None A FM/CSA Explosion proof N Electrical connection / cable inlet Screwed gland M0x1.5 B Screwed gland ½-14 NPT C M1 connectors (metal) F Display Without (digital display hidden) 1 With visible digital display 6 With customer-specific digital display (setting as 7 specified, Order code "Y1" or required) Included in delivery of the device: Brief instructions (Leporello) CD-ROM with detailed documentation Sealing ring F) Subject to export regulations AL: 9I999, ECCN: N. F) Subject to export regulations AL: 9I999, ECCN: N. 1) Only with "PMC Style Standard" process connection Siemens FI US Edition /43

44 Transmitters for gage pressure for the paper industry DS III series with PMC connection Siemens AG 007 Selection and Ordering data Order code Further designs HART PA FF Add "-Z" to Order No. and specify Order code. M1 cable sockets (metal) A50 Rating plate inscription (instead of German) English B11 French B1 Spanish B13 Italian B14 English rating plate B1 Pressure units in inh O or psi Manufacturer's test certificate M (calibration certificate) To DIN 55350, Part 18 and to ISO 840 C11 Acceptance test certificate C1 To EN Factory certificate C14 To EN Output signal can be set to upper limit of.0 ma Mounting Weldable sockets for standard 1½" threaded connection Weldable socket for mini bolt connection 1" (incl. screw 5/16-18 UNC-B and washer) D05 P01 P0 Selection and Ordering data Order code Additional data HART PA FF Add "-Z" to Order No. and specify Order code. Measuring range to be set Y01 Specify in plain text (max. 5 digits): Y01:... up to... mbar, bar, kpa, MPa, psi Measuring point number (TAG No.) Y15 Max. 16 characters, specify in plain text: Y15:... Measuring point text Y16 Max. 7 characters, specify in plain text: Y16:... Entry of HART address (TAG) Y17 Max. 8 characters, specify in plain text: Y17:... Setting of pressure indication in pressure Y1 units Specify in plain text (standard setting: ma): Y1: mbar, bar, kpa, MPa, psi,... Note: The following pressure units can be selected: bar, mbar, mm H O *), inh O *), fth O *), mmhg, inhg, psi, Pa, kpa, MPa, g/cm, kg/cm, Torr, ATM or % *) ref. temperature 0 C Setting of pressure indication in Y + non-pressure units Y01 Specify in plain text: Y:... up to... l, m 3, m, USg,... (specification of measuring range in pressure units "Y01" is essential, unit with max. 5 characters) Preset bus address Y5 Max. 8 characters, specify in plain text: Y5:... Only "Y01" and "Y1" can be factory preset = available Ordering example Item line: 7MF4133-1DB0-1AB7-Z B line: A + Y01 + Y1 C line: Y01: bar ( psi) C line: Y1: bar (psi) /44 Siemens FI US Edition

45 Siemens AG 007 Transmitters for gage pressure for the paper industry DS III series with PMC connection Dimensional drawings 15 (0.6) 74 (.9) 144 (567) 51 (.0) approx. 30 (1.18) 100 (3.94) 6 Ø 80 (3.15) 0 (0.8) 5 1) 1 77 (3) ) 4 1) Space for rotation of housing 50 (1.97) 3 9 H 1 = approx. 130 (5.1) H 1 Process connection: PMC standard Blanking plug 3 Electrical connection: - screwed gland M0x1,5 - screwed gland ½-14 NPT 4 Terminal side 5 Electronics side, digital display (longer overall length for cover with window) 6 Protective cover over keys 7 Mounting bracket (option) 8 Sealing srew with valve (option) 9 Screw cover safety bracket (only for explosion-proof enclosure, not shown in the drawing) 1) Allow approx. 0 mm (0.79 inch) thread length in addition ) 9 mm (3.6 inch) for minimum distance to permit rotation with indicator SITRANS P DS III pressure transmitters for gage pressure, with PMC connection, dimensions in mm (inch) The diagram shows a SITRANS P DS III with an example of a flange. In this drawing the height is subdivided into H 1 and H. H 1 = Height of the SITRANS P DS III up to a defined cross-section H = Height of the flange up to this defined cross-section Only the height H is indicated in the dimensions of the flanges. PMC Style standard DN PN D H 40.9 mm (1.6") Approx mm (1.4 ) PMC Style minibolt DN PN D H 6.3 mm (1.0") Approx mm (1.3 ) PMC Style standard (left) and PMC Style minibolt (right) weldable sockets, dimensions in mm (inch) Material: Stainless steel, mat. No / 316L Siemens FI US Edition /45

46 Transmitters for gage pressure for the paper industry SITRANS P300 with PMC connection Siemens AG 007 Technical specifications SITRANS P300 for gage pressure with PMC connection for the paper industry Input Measured variable Spans (infinitely adjustable) or nominal measuring range and max. permissible test pressure HART Gage pressure (flush-mounted) Span Max. perm. test pressure bar g ( psi g) bar g ( psi g) bar g ( psi g) 6 bar g (87 psi g) 10 bar g (145 psi g) 3 bar g (464 psi g) PROFIBUS PA Nominal measuring range 1 bar g (14.5 psi g) 4 bar g (58 psi g) 16 bar g (3 psi g) Max. perm. test pressure 6 bar g (87 psi g) 10 bar g (145 psi g) 3 bar g (464 psi g) Depending on the process connection, the span may differ from these values Depending on the process connection, the nominal measuring range may differ from these values Lower measuring limit Measuring cell with silicone oil 100 mbar a (1.45 psi a) Upper measuring limit Measuring cell with silicone oil 100% of max. span 100% of the max. nominal measuring range Output Output signal ma Digital PROFIBUS PA signal Physical bus - IEC With polarity reversal protection No Yes Electrical damping T 63 (step width 0.1 s) Set to 0.1 s ( s) Accuracy To EN Reference conditions Increasing characteristic, start-of-scale value 0 bar, stainless steel seal diaphragm, measuring cell with silicone oil, room temperature 5 C (77 F), span ratio (r = max. span/set span) Measurement deviation with cut-off point setting, including hysteresis and repeatability. Linear characteristic curve 0,075% r 10 (0.009 r )% 10 < r 30 ( r )% 30 < r 100 (0.005 r )% Settling time T 63 without electrical damping Approx. 0. s Long-term drift at ±30 C (±54 F) (0.5 r)%/5 years 0.5%/5 years Influence of ambient temperature at C ( F) (0.1 r + 0.)% 0,3% at C and C (0.1 r )%/10 K 0.5%/10 K ( F and F) Influence of the medium temperature (only with front-flush diaphragm) Temperature difference between medium 3 mbar/10 K (0.04 psi/10 K) temperature and ambient temperature Rated operating conditions Installation conditions Ambient temperature Observe the temperature class in areas subject to explosion hazard. Measuring cell with silicone oil C ( F) Digital display C ( F) Storage temperature C ( F) Climatic class Condensation Permissible Degree of protection to EN 6059 IP65, IP68, NEMA X, enclosure cleaning, resistant to lyes, steam to 150 C (30 F) Electromagnetic compatibility Emitted interference and interfer. immunity To EN 6136 and NAMUR NE 1 Medium conditions Process temperature Measuring cell with silicone oil C ( F) /46 Siemens FI US Edition

47 Siemens AG 007 Transmitters for gage pressure for the paper industry SITRANS P300 with PMC connection SITRANS P300 for gage pressure with PMC connection for the paper industry HART Design Weight (without options) Approx. 1 kg (. lb) Housing material Stainless steel, mat. No /304 Material of parts in contact with the medium Seal diaphragm Hastelloy C76, mat. No Measuring cell filling Silicone oil Power supply U H PROFIBUS PA Terminal voltage on transmitter V DC Supplied through bus for intrinsically safe operation: V DC Separate power supply - Not necessary Bus voltage Without EEx V For intrinsically-safe operation V Current consumption Max. basic current ma Startup current basic current - Yes Max. fault current in the event of a fault ma Fault disconnection electronics (FDE) - Available Certificate and approvals Classification according to pressure equipment directive (DRGL 97/3/EC) Explosion protection For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of Article 3, paragraph 3 (sound engineering practice) Intrinsic safety "i" PTB 05 ATEX 048 Identification Ex II 1/ G EEx ia/ib IIB/IIC T4, T5, T6 Permissible ambient temperature Temperature class T C ( F) Temperature class T C ( F) Temperature class T C ( F) Connection To certified intrinsically-safe circuits with maximum values: U i = 30 V, I i = 100 ma, P i = 750 mw, R i = 300 Ω To certified intrinsically-safe circuits with maximum values: FISCO supply unit: U i = 17.5 V, I i = 380 ma, P i = 5.3 W Linear barrier: U i = 4 V, I i = 50 ma, P i = 1. W Effective inner capacitance: C i = 6 nf C i = 1.1 nf Effective inner inductance: L i = 0.4 mh L i 7 µh Explosion protection to FM for USA and Canada (cfm US ) Identification (DIP) or (IS); (NI) Certificate of Compliance CL I, DIV 1, GP ABCD T4... T6; CL II, DIV 1, GP EFG; CL III; CL I, ZN 0/1 AEx ia IIC T4... T6; CL I, DIV, GP ABCD T4... T6; CL II, DIV, GP FG; CL III Identification (DIP) or (IS) Certificate of Compliance C CL I, DIV 1, GP ABCD T4... T6; CL II, DIV 1, GP EFG; CL III; Ex ia IIC 4... T6; CL I, DIV, GP ABCD T4... T6; CL II, DIV, GP FG; CL III Siemens FI US Edition /47

48 Transmitters for gage pressure for the paper industry SITRANS P300 with PMC connection Siemens AG 007 SITRANS P300 for gage pressure with PMC connection for the paper industry HART communication HART communication Ω Protocol HART Version 5.x Software for computer SIMATIC PDM PROFIBUS PA communication Simultaneous communication with master class (max.) 4 The address can be set using configuration tool Local operation (standard setting Address 16) Cyclic data usage Output byte One measuring value: 5 bytes Two measuring values: 10 bytes Input byte Register operating mode: 1 bytes Reset function due to metering. 1bytes Device profile PROFIBUS PA Profile for Process Control Devices Version 3.0, Class B Function blocks Analog input - Adaptation to customer-specific process variables Linearly rising or falling characteristic - Electrical damping T s adjustable - Simulation function Input /Output - Limit monitoring One upper and lower warning limit and one alarm limit respectively Register (totalizer) Can be reset and preset Optional direction of counting Simulation function of the register output - Limit monitoring One upper and lower warning limit and one alarm limit respectively Physical block 1 Transducer blocks Pressure transducer block - Monitoring of sensor limits Yes - Characterizer Max. 30 points - Characteristic Linear - Simulation function Available Transducer block "Electronic temperature" - Simulation function Available /48 Siemens FI US Edition

49 Siemens AG 007 Transmitters for gage pressure for the paper industry SITRANS P300 with PMC connection Selection and Ordering data F) Subject to export regulations AL: 9I999, ECCN: N. Order No. SITRANS P300 pressure transmitters with PMC connection, single-chamber measuring housing, rating plate inscription in English ma/hart F) 7 M F PROFIBUS PA F) 7 M F FOUNDATION Fieldbus (FF) F) 7 M F Measuring cell filling Measuring cell cleaning Silicone oil Standard 1 Inert liquid Cleanliness level to 3 DIN 5410 Span 1 bar g (14.5 psi g) B 4 bar g (58 psi g) C 16 bar g (3 psi g) D Wetted parts materials Seal diaphragm Measuring cell Hastelloy Stainless steel B Process connection PMC Style Standard: Thread 1½" PMC Style Mini bolt: 1" front-flush 3 (not with span - version "B") Non-wetted parts materials Stainless steel, deep-drawn and electrolytically 4 polished Version Standard version 1 Explosion protection None A With ATEX, Type of protection: - "Intrinsic safety (EEx ia)" B With FM + CSA, Type of protection: - "Intrinsic Safe (is)" (planned) M Electrical connection / cable entry Screwed gland M0x1.5 (Polyamide) 1) A Screwed gland M0x1.5 (metal) B Screwed gland M0x1.5 (stainless steel) C M1 connector (without cable socket) F M1 connector (stainless steel, without cable G socket) ½-14 NPT thread, metal ) H ½-14 NPT thread, stainless steel ) J Display Without display, with keys, closed lid 1) 1 With display and keys, closed lid With display and keys, lid with glass pane 6 (setting on HART devices: ma, on PROFIBUS PA and FOUNDATION Fieldbus devices: pressure unit) With display (setting acc. to specifications, 7 Order code "Y1" or "Y" required), lid with glass pane Power supply units see "SITRANS I power supply units and isolation amplifiers". Included in delivery of the device: Brief instructions (Leporello) CD-ROM with detailed documentation Sealing ring 1) Only together with HART electronics. ) Without cable gland. Selection and Ordering data Order code Further designs HART PA FF Add "-Z" to Order No. and specify Order code. Cable socket for M1 plug Metal A50 Stainless steel A51 Rating plate inscription (instead of English) German B10 French B1 Spanish B13 Italian B14 English rating plate B1 Pressure units in inh O or psi Manufacturer's test certificate M (calibration certificate) To DIN 55350, Part 18 and to ISO 840 C11 Acceptance test certificate C1 To EN Factory certificate C14 To EN Set output signal to upper limit of.0 ma D05 Type of protection IP68 D1 Mounting Weldable sockets for standard 1½" threaded P01 connection Weldable socket for mini bolt connection 1" P0 (incl. screw 5/16-18 UNC-B and washer) Additional data Add "-Z" to Order No. and specify Order code. Measuring range to be set Y01 Specify in plain text (max. 5 digits): Y01:... up to... mbar, bar, kpa, MPa, psi Measuring point number (TAG No.) Y15 Max. 16 characters, specify in plain text: Y15:... Measuring point text Y16 Max. 7 characters, specify in plain text: Y16:... Entry of HART address (TAG) Y17 Max. 8 characters, specify in plain text: Y17:... Setting of pressure indication in pressure Y1 units Specify in plain text (standard setting: ma): Y1: mbar, bar, kpa, MPa, psi,... Note: The following pressure units can be selected: bar, mbar, mm H O *), inh O *), fth O *), mmhg, inhg, psi, Pa, kpa, MPa, g/cm, kg/cm, Torr, ATM or % *) ref. temperature 0 C Setting of pressure indication in non-pressure Y + units Y01 Specify in plain text: Y:... up to... l, m 3, m, USg,... (specification of measuring range in pressure units "Y01" is essential, unit with max. 5 characters) Preset bus address Y5 Specify in plain text: Y5:... Only "Y01" and "Y1" can be factory preset = available Siemens FI US Edition /49

50 Transmitters for gage pressure for the paper industry SITRANS P300 with PMC connection Siemens AG 007 Dimensional drawings SITRANS P300 pressure transmitters for gage pressure, with PMC connection, dimensions in mm (inch) The diagram shows a SITRANS P300 with an example of a flange. In this drawing the height is subdivided into H 1 and H. H 1 = Height of the SITRANS P300 up to a defined cross-section H = Height of the flange up to this defined cross-section Only the height H is indicated in the dimensions of the flanges. PMC Style Standard DN PN D H 40.4 mm (1.6") Approx mm (1.4 ) PMC Style Minibolt DN PN D H 6.3 mm (1.0") Approx mm (1.3 ) PMC Style Standard (left) and PMC Style Minibolt (right) weldable sockets, dimensions in mm (inch) Material: Stainless steel, mat. No / 316L /50 Siemens FI US Edition

51 Siemens AG 007 Transmitters for gage, absolute and differential pressure, flow and level DS III series Technical description Overview SITRANS P pressure transmitters, DS III series, are digital pressure transmitters featuring extensive user-friendliness and high accuracy. The parameterization is performed using control keys, over HART communication, PROFIBUS-PA or FOUNDATION Fieldbus interface. Extensive functionality enables the pressure transmitter to be precisely adapted to the plant s requirements. Operation is very simple in spite of the numerous setting options. Transmitters with type of protection "Intrinsic safety" and "Explosion-proof" may be installed within potentially explosive atmospheres (zone 1) or in zone 0. The transmitters are provided with an EC type examination certificate and comply with the corresponding harmonized European standards (ATEX). The transmitters can be equipped with various designs of remote seals for special applications such as the measurement of highly viscous substances. Various versions of the DS III pressure transmitters are available for measuring: Gage pressure Absolute pressure For differential pressure transmitters Filling level Mass level Volume level Volume flow Mass flow Benefits High quality and long life High reliability even under extreme chemical and mechanical loads For aggressive and non-aggressive gases, vapors and liquids Extensive diagnosis and simulation functions Separate replacement of measuring cell and electronics without recalibration Minimum conformity error Small long-term drift Wetted parts made of high-grade materials (e.g. stainless steel, Hastelloy, gold, Monel, tantalum) Infinitely adjustable span from 0.01 bar to 400 mbar ( 0.15 psi to 5800 psi) for DS III with HART communication Nominal measuring range from 1 to 400 bar (14.5 to 5800 psi) for DS III PA (PROFIBUS PA) and FF (FOUNDATION Fieldbus) High measuring accuracy Parameterization over control keys and HART communication, PROFIBUS PA communication or FOUNDATION Fieldbus interface. Application The pressure transmitters of the DS III series, can be used in industrial areas with extreme chemical and mechanical loads. Electromagnetic compatibility in the range 10 khz to 1 GHz makes the DS III pressure transmitters suitable for locations with high electromagnetic emissions. Pressure transmitters with type of protection "Intrinsic safety" and "Explosion-proof" may be installed within potentially explosive atmospheres (zone 1) or in zone 0. The pressure transmitters are provided with an EC type examination certificate and comply with the corresponding harmonized European standards (ATEX). Pressure transmitters with the type of protection "Intrinsic safety" for use in zone 0 may be operated with power supply units of category "ia" and "ib". The transmitters can be equipped with various designs of remote seals for special applications such as the measurement of highly viscous substances. The pressure transmitter can be operated locally over 3 control keys or programmed externally over HART communication or over PROFIBUS PA or FOUNDATION Fieldbus interface. Siemens FI US Edition /51

52 Transmitters for gage, absolute and differential pressure, flow and level DS III series Technical description Pressure transmitter for gage pressure Design Measured variable: Gage pressure of aggressive and non-aggressive gases, vapors and liquids. Span (infinitely adjustable) for DS III HART: bar g ( psi g) Nominal measuring range for DS III PA and FF: bar g ( psi g) Pressure transmitters for absolute pressure Measured variable: Absolute pressure of aggressive and nonaggressive gases, vapors and liquids. Span (infinitely adjustable) for DS III HART: 8.3 mbar a bar a ( psi a) Nominal measuring range for DS III PA and FF: 50 mbar a bar a ( psi a) There are two series: - Gage pressure series - Differential pressure series Pressure transmitters for differential pressure and flow Measured variables: - Differential pressure - Small positive or negative pressure -Flow q ~ p (together with a primary differential pressure device (see Chapter "Flow Meters")) Span (infinitely adjustable) for DS III HART: 1 mbar bar ( psi) Nominal measuring range for DS III PA and FF: 0 mbar bar ( psi) Pressure transmitters for level Measured variable: Level of aggressive and non-aggressive liquids in open and closed vessels. Span (infinitely adjustable) for DS III HART: 5 mbar... 5 bar ( psi) Nominal measuring range for DS III PA and FF: 50 mbar... 5 bar ( psi) Nominal diameter of the mounting flange - DN 80 or DN inch or 4 inch In the case of level measurements in open containers, the lowpressure connection of the measuring cell remains open (measurement "compared to atmospheric"). In the case of measurements in closed containers, the lowerpressure connection has to be connected to the container in order to compensate the static pressure. The wetted parts are made from a variety of materials, depending on the degree of corrosion resistance required. Siemens AG 007 Front view The transmitter consists of various components depending on the order. The possible versions are listed in the ordering information. The components described below are the same for all transmitters. The rating plate (3, Figure "Front view") with the Order No. is located on the side of the housing. The specified number together with the ordering information provide details on the optional design details and on the possible measuring range (physical properties of built-in sensor element). The approval label is located on the opposite side. The housing is made of die-cast aluminium or stainless steel precision casting. A round cover is screwed on at the front and rear of the housing. The front cover (6) can be fitted with a viewing pane so that the measured values can be read directly on the digital display. The inlet (4) for the electrical connection is located either on the left or right side. The unused opening on the opposite side is sealed by a blanking plug. The protective earth connection is located on the rear of the housing. The electrical connections for the power supply and screen are accessible by unscrewing the rear cover. The bottom part of the housing contains the measuring cell with process connection (1). The measuring cell is prevented from rotating by a locking screw (8). As the result of this modular design, the measuring cell and the electronics can be replaced separately from each other. The set parameter data are retained. At the top of the housing is a plastic cover (5), which hides the input keys. /5 Siemens FI US Edition

53 Transmitters for gage, absolute and differential pressure, flow and level DS III series Technical description Function Mode of operation of the DS III HART electronics 1 Sensor 8 M 3 EEPROM 6 4 mc HART interface EEPROM 6 Electronics 10 Siemens AG 007 I A, U H Mode of operation of the DS III PA electronics 1 Sensor p e 8 M mc PA interface EEPROM Measuring cell EEPROM 6 Electronics PROFIBUS-PA Power supply 10 Power supply unit Coupler 11 1 PROFIBUS-DP Bus- Master P e Measuring cell 1 Measuring cell sensor Instrument amplifier 3 Analog-to-digital converter 4 Microcontroller 5 Digital-to-analog converter 6 One non-volatile memory each in the measuring cell and electronics 7 HART interface 8 Three input keys (local operation) 9 Digital display 10 Diode circuit and connection for external ammeter I A Output current U H Power supply P e Input variable Function diagram of the electronics The bridge output voltage created by the sensor (1, Figure "Function diagram of the electronics") is amplified by the instrument amplifier () and digitized in the analog-to-digital converter (3). The digital information is evaluated in a microcontroller, its linearity and temperature response corrected, and converted in a digital-to-analog converter (5) into an output current of 4 to 0 ma. The diode circuit (10) protects against incorrect polarity. The data specific to the measuring cell, the electronics data, and the parameter data are stored in the two non-volatile memories (6). The one memory is coupled to the measuring cell, the other to the electronics. As the result of this modular design, the electronics and the measuring cell can be replaced separately from each other. Using the 3 input keys (8) you can parameterize the pressure transmitter directly at the point of measurement. The input keys can also be used to control the view of the results, the error messages and the operating modes on the digital display (9). The HART modem (7) permits parameterization using a protocol according to the HART specification. The pressure transmitters with spans 63 bar measure the input pressure compared to atmosphere, transmitters with spans 160 bar compared to vacuum. 1 Measuring cell sensor Instrument amplifier 3 Analog-to-digital converter 4 Microcontroller 5 Electrical isolation 6 One non-volatile memory each in the measuring cell and electronics 7 PROFIBUS-PA interface 8 Three input keys (local operation) 9 Digital display 10 Power supply 11 DP/PA coupler or link 1 Bus master Function diagram of the electronics The bridge output voltage created by the sensor (1, Figure "Function diagram of the electronics") is amplified by the instrument amplifier () and digitized in the analog-to-digital converter (3). The digital information is evaluated in the microcontroller, its linearity and temperature response corrected, and provided on the PROFIBUS PA through an electrically isolated PA interface (7). The data specific to the measuring cell, the electronics data, and the parameter data are stored in the two non-volatile memories (6). The first memory is linked with the measuring cell, the second with the electronics. This modular design means that the electronics and the measuring cell can be replaced separately from one another. Using the three input keys (8) you can parameterize the pressure transmitter directly at the point of measurement. The input keys can also be used to control the view of the results, the error messages and the operating modes on the digital display (9). The results with status values and diagnostic values are transferred by cyclic data transmission on the PROFIBUS PA. Parameterization data and error messages are transferred by acyclic data transmission. Special software such as SIMATIC PDM is required for this. p e Input variable Siemens FI US Edition /53

54 Transmitters for gage, absolute and differential pressure, flow and level DS III series Technical description Mode of operation of the DS III FF electronics 8 M Siemens AG 007 Mode of operation of the measuring cells Measuring cell for gage pressure 1 Sensor p e mc FF interface EEPROM 6 Measuring cell EEPROM 1 Measuring cell sensor Instrument amplifier 3 Analog-to-digital converter 4 Microcontroller 5 Electrical isolation 6 One non-volatile memory each in the measuring cell and electronics 7 FF interface Function diagram of the electronics The bridge output voltage created by the sensor (1, Figure "Function diagram of the electronics") is amplified by the instrument amplifier () and digitized in the analog-to-digital converter (3). The digital information is evaluated in the microcontroller, its linearity and temperature response corrected, and provided on the FOUNDATION Fieldbus through an electrically isolated FOUNDATION Fieldbus Interface (7). The data specific to the measuring cell, the electronics data, and the parameter data are stored in the two non-volatile memories (6). The one memory is coupled to the measuring cell, the other to the electronics. As the result of this modular design, the electronics and the measuring cell can be replaced separately from each other. Using the three input keys (8) you can parameterize the pressure transmitter directly at the point of measurement. The input keys can also be used to control the view of the results, the error messages and the operating modes on the digital display (9). The results with status values and diagnostic values are transferred by cyclic data transmission on the FOUNDATION Fieldbus. Parameterization data and error messages are transferred by acyclic data transmission. Special software such as National Instruments Configurator is required for this. 6 Electronics Power supply 10 Power supply unit Coupler 8 Three input keys (local operation) 9 Digital display 10 Power supply p e Input variable p e 1 1 Measuring cell Process connection 3 Seal diaphragm 4 Filling liquid 5 Silicon pressure sensor p e Pressure as input variable Measuring cell for gage pressure, function diagram The pressure pe is applied through the process connection (, Figure "Measuring cell for gage pressure, function diagram) to the measuring cell (1). This pressure is subsequently transmitted further through the seal diaphragm (3) and the filling liquid (4) to the silicon pressure sensor (5) whose measuring diaphragm is then flexed. This changes the resistance of the four piezo-resistors fitted in the diaphragm in a bridge circuit. This change in resistance results in a bridge output voltage proportional to the input pressure. Measuring cell for gage pressure, with front-flush diaphragm for paper industry p e 1 1 Measuring cell Process connection 3 Seal diaphragm 4 Filling liquid 5 Silicon pressure sensor p e Pressure as input variable Measuring cell for gage pressure, with front-flush diaphragm for paper industry, function diagram The pressure pe is applied through the process connection (, Figure "Measuring cell for gage pressure, with front-flush diaphragm for paper industry, function diagram") to the measuring cell (1). This pressure is subsequently transmitted further through the seal diaphragm (3) and the filling liquid (4) to the silicon pressure sensor (5) whose measuring diaphragm is then flexed. This changes the resistance of the four piezo-resistors fitted in the diaphragm in a bridge circuit. This change in resistance results in a bridge output voltage proportional to the input pressure. /54 Siemens FI US Edition

55 Transmitters for gage, absolute and differential pressure, flow and level DS III series Technical description Measuring cell for absolute pressure from gage pressure series Siemens AG 007 Measuring cell for differential pressure and flow p e 1 Measuring cell Process connection 3 Seal diaphragm 4 Filling liquid 5 Silicon absolute pressure sensor p e Absolute pressure as input variable Measuring cell for absolute pressure from the pressure series, function diagram The absolute pressure p e is transmitted through the seal diaphragm (3, Figure "Measuring cell for absolute pressure from the gage pressure series, function diagram") and the filling liquid (4) to the silicon absolute pressure sensor (5) whose measuring diaphragm is then flexed. This changes the resistance of the four piezo-resistors fitted in the diaphragm in a bridge circuit. This change in resistance results in a bridge output voltage proportional to the input pressure. Measuring cell for absolute pressure from differential pressure series Seal diaphragm O-ring 3 Overload diaphragm 4 Silicon pressure sensor 5 Process flange 6 Body of measuring cell 7 Filling liquid Measuring cell for differential pressure and flow, function diagram The differential pressure is transmitted through the seal diaphragms (1, Figure "Measuring cell for differential pressure and flow, function diagram") and the filling liquid (7) to the silicon pressure sensor (4). The measuring diaphragm is flexed by the applied differential pressure. This changes the resistance of the four piezo-resistors fitted in the diaphragm in a bridge circuit. This change in resistance results in a bridge output voltage proportional to the absolute pressure. An overload diaphragm is installed to provide protection from overloads. If the measuring limits are exceeded, the overload diaphragm () is flexed until the seal diaphragm rests on the body of the measuring cell (7), thus protecting the silicon pressure sensor from overloads. Measuring cell for level p e 6 1 Reference vacuum Overload diaphragm 3 Silicon pressure sensor 4 O-ring 5 Process flange 6 Seal diaphragm 7 Body of measuring cell 8 Filling liquid p e Absolute pressure as input variable Flange with tube Seal diaphragm on mounting flange 3 Seal diaphragm 4 Body of measuring cell 5 Overload diaphragm 9-6 Silicon pressure sensor 7 O-ring 8 Process flange 9 Filling liquid 10 Capillary with filling liquid of mounting flange 8 Measuring cell for absolute pressure from differential pressure series, function diagram The input pressure p e is transmitted through the seal diaphragm (6, Figure "Measuring cell for absolute pressure from differential pressure series, function diagram") and the filling liquid (8) to the silicon pressure sensor (3). The difference in pressure between the input pressure pe and the reference vacuum (1) on the low-pressure side of the measuring cell flexes the measuring diaphragm. The resistance of the four piezo-resistors fitted in the diaphragm in a bridge circuit thus changes. This change in resistance results in a bridge output voltage proportional to the absolute pressure. An overload diaphragm is installed to provide protection from overloads. If the measuring limits are exceeded, the overload diaphragm () is flexed until the seal diaphragm rests on the body of the measuring cell (7), thus protecting the silicon pressure sensor from overloads. Measuring cell for level, function diagram The input pressure (hydrostatic pressure) acts hydraulically on the measuring cell through the seal diaphragm on the mounting flange (, Figure "Measuring cell for level, function diagram"). This differential pressure is subsequently transmitted further through the measuring cell (3) and the filling liquid (9) to the silicon pressure sensor (6) whose measuring diaphragm is then flexed. This changes the resistance of the four piezo-resistors fitted in the diaphragm in a bridge circuit. This change in resistance results in a bridge output voltage proportional to the differential pressure. An overload diaphragm is installed to provide protection from overloads. If the measuring limits are exceeded, the overload diaphragm () is flexed until the seal diaphragm rests on the body of the measuring cell (7), thus protecting the silicon pressure sensor from overloads. Siemens FI US Edition /55

56 Transmitters for gage, absolute and differential pressure, flow and level DS III series Technical description Parameterization DS III Depending on the version, there are a range of options for parameterizing the pressure transmitter and for setting or scanning the parameters. Parameterization using the pushbuttons (local operation) With the input keys you can easily set the most important parameters without any additional equipment. Parameterization using HART communication Parameterization using HART communication is performed with a HART communicator or a PC. SITRANS P transmitter Communication between a HART communicator and a pressure transm. When parameterizing with the HART communicator, the connection is made directly to the -wire system. SITRANS P transmitter HART communication between a PC communicator and a pressure transmitter When parameterizing with a PC, the connection is made through a HART modem. The signals needed for communication in conformity with the HART 5.x or 6.x protocols are superimposed on the output current using the Frequency Shift Keying (FSK) method. Adjustable parameters, DS III HART Parameters HART communicator HART modem W PC or laptop RS W Pushbuttons (DS III HART) Start of scale x x Full-scale value x x Electrical damping x x Start-of-scale value without application x x of a pressure ("Blind setting") Full-scale value without application of a x x pressure ("Blind setting") Zero adjustment x x Current transmitter x x Fault current x x Disabling of keys, write protection x x 1) Type of dimension and actual dimension x x Characteristic (linear / square-rooted) x ) x ) Input of characteristic x Freely-programmable LCD x Diagnostics functions x 1) Cancel apart from write protection ) Only differential pressure + Power supply Power supply Siemens AG 007 Diagnostic functions for DS III HART Zero correction display Event counter Limit transmitter Saturation alarm Min/Max registers Simulation functions Maintenance timer Available physical units of display for DS III HART Table style: Technical specifications Physical variable Physical dimensions Pressure (setting can also be made in the factory) Pa, MPa, kpa, bar, mbar, torr, atm, psi, g/cm, kg/cm, inh O, inh O (4 C), mmh O, fth O (0 C), inhg, mmhg HART communication Level (height data) m, cm, mm, ft, in Volume m 3, dm 3, hl, yd 3, ft 3, in 3, US gallon, lmp. gallon, bushel, barrel, barrel liquid Mass g, kg, t, lb, Ston, Lton, oz Volume flow m 3 /d, m 3 /h, m 3 /s, l/min, l/s, ft 3 /d, ft 3 /min, ft 3 /s, US gallon/min, US gallon/s Mass flow t/d, t/h, t/min, kg/d, kg/h, kg/min, kg/s, g/d, g/h, g/min, g/s, lb/d, lb/h, lb/min, lb/s, LTon/d, LTon/h, STon/d, STon/h, STon/min Temperature K, C, F, R Miscellaneous %, ma Parameterization through PROFIBUS PA interface Fully digital communication through PROFIBUS PA, profile 3.0, is particularly user-friendly. The PROFIBUS puts the DS III PA is in connection with a process control system, e.g. SIMATIC PSC 7. Communication is possible even in a potentially explosive environment. For parameterization through PROFIBUS you need suitable software, e.g. SIMATIC PDM (Process Device Manager). Parameterization through FOUNDATION Fieldbus Interface Fully digital communication through FOUNDATION Fieldbus is particularly user-friendly. Through the FOUNDATION Fieldbus the DS III FF is connected to a process control system. Communication is possible even in a potentially explosive environment. For parameterization through the FOUNDATION Fieldbus you need suitable software, e.g. National Instruments Configurator. Adjustable parameters for DS III PA and FF Parameters Pushbuttons PROFIBUS PA and (DS III FOUNDATION HART) Fieldbus interface Electrical damping x x Zero adjustment (correction of x x position) Key and/or function disabling x x Source of measured-value display x x Physical dimension of display x x Position of decimal point x x Bus address x x Adjustment of characteristic x x Input of characteristic x Freely-programmable LCD x Diagnostics functions x /56 Siemens FI US Edition

57 Transmitters for gage, absolute and differential pressure, flow and level DS III series Technical description Diagnostic functions for DS III PA and FF Event counter Min/Max registers Maintenance timer Simulation functions Display of zero correction Limit transmitter Saturation alarm Physical dimensions available for the display Physical variable Physical dimensions Pressure (setting can also be made in the factory) Level (height data) Volume MPa, kpa, Pa, bar, mbar, torr, atm, psi, g/cm, kg/cm, mmh O, mmh O (4 C), inh O, inh O (4 C), fth O (0 C), mmhg, inhg m, cm, mm, ft, in, yd m 3, dm 3, hl, yd 3, ft 3, in 3, US gallon, lmp. gallon, bushel, barrel, barrel liquid Volume flow m 3 /s, m 3 /min, m 3 /h, m 3 /d, l/s, l/min, l/h, l/ d, Ml/d, ft 3 /s, ft 3 /min, ft 3 /h, ft 3 /d, US gallon/s, US gallon/min, US gallon/h, US gallon/d, bbl/s, bbl/min, bbl/h, bbl/d Mass flow g/s, g/min, g/h, g/d, kg/s, kg/min, kg/h, kg/d, t/s, t/min, t/h, /t/d, lb/s, lb/min, lb/h, lb/d, STon/s, STon/min, STon/h, STon/d, LTon/s, LTon/min, LTon/h, LTon/d Total mass flow t, kg, g, lb, oz, LTon, STon Temperature K, C, F, R Miscellaneous % Siemens AG 007 Siemens FI US Edition /57

58 Transmitters for gage, absolute and differential pressure, flow and level DS III series for gage pressure Technical specifications SITRANS P, DS III series for gage pressure HART Input Measured variable Gage pressure Spans (infinitely adjustable) or Span nominal measuring range and max. permissible test pressure bar g ( psi g) bar g ( psi g) bar g ( psi g) bar g ( psi g) bar g ( psi g) bar g ( psi g) Lower measuring limit Measuring cell with silicone oil filling 30 mbar a (0.435 psi a) Measuring cell with inert filling liquid 30 mbar a (0.435 psi a) Upper measuring limit Output Siemens AG 007 Max. perm. test pressure 6 bar g (87 psi g) 10 bar g (145 psi g) 3 bar g (464 psi g) 100 bar g (1450 psi g) 50 bar g (366 psi g) 600 bar g (8700 psi g) PROFIBUS PA or FOUNDATION Fieldbus Nominal measuring range 1 bar g (14.5 psi g) 4 bar g (58 psi g) 16 bar g (3 psi g) 63 bar g (914 psi g) 160 bar g (30 psi g) 400 bar g (580 psi g) Max. perm. test pressure 6 bar g (87 psi g) 10 bar g (145 psi g) 3 bar g (464 psi g) 100 bar g (1450 psi g) 50 bar g (366 psi g) 600 bar g (8700 psi g) 100% of max. span (max. 160 bar g (30 psi g) with oxygen measurement and inert liquid) Output signal ma Digital PROFIBUS PA or FOUNDATION Fieldbus signal Lower limit (infinitely adjustable) 3.55 ma, factory preset to 3.84 ma - Upper limit (infinitely adjustable) 3 ma, factory preset to 0.5 ma or optionally set - to.0 ma Load Without HART communication R B (U H V)/0.03 A in Ω, - U H : Power supply in V With HART communication R B = Ω (SIMATIC PDM) or - R B = Ω (HART Communicator) Physical bus - IEC With polarity reversal protection - Yes Accuracy To EN Reference conditions Increasing characteristic, start-of-scale value 0 bar, stainless steel seal diaphragm, silicone oil filling, room temperature 5 C (77 F)) r: Span ratio (r = max. span/set span) Error in measurement and fixed-point setting (including hysteresis and repeatability) Linear characteristic 0,075% -r 10 (0.009 r )% - 10 < r 30 ( r )% - 30 < r 100 (0.005 r )% Long-term drift (temperature change ±30 C (0.5 r)% every 5 years 0.5% every 5 years (±54 F)) Influence of ambient temperature at C ( F) (0.08 r + 0.1)% 0,3% at C and C (0.1 r )%/10 K 0.5%/10 K ( F and F) Measured Value Resolution of nominal measuring range /58 Siemens FI US Edition

59 Siemens AG 007 Transmitters for gage, absolute and differential pressure, flow and level DS III series for gage pressure SITRANS P, DS III series for gage pressure Rated operating conditions HART PROFIBUS PA or FOUNDATION Fieldbus Degree of protection (to EN 6059) IP65 Process temperature Measuring cell with silicone oil filling C ( F) Measuring cell with inert filling liquid C ( F) In conjunction with dust explosion protection C ( F) Ambient conditions Ambient temperature - Digital indicators C ( F) Storage temperature C ( F) Climatic class - Condensation Permissible Electromagnetic compatibility - Emitted interference and interference To EN 6136 and NAMUR NE 1 immunity Design Weight (without options) 1.5 kg ( 3.3 lb) Housing material Low copper die-cast aluminium, GD-AlSi1 or stainless steel precision casting, mat. No Wetted parts materials Connection shank Stainless steel, mat. No /316L or Hastelloy C4, mat. No Oval flange Stainless steel, mat. No /316L Seal diaphragm Stainless steel, mat. No /316L or Hastelloy C76, mat. No Measuring cell filling Silicone oil or inert filling liquid (max. 160 bar (30 psi g) with oxygen measurement) Process connection Connection shank G½A to DIN EN 837-1, female thread ½ -14 NPT or oval flange (PN 160 (MWP 30 psi g)) to DIN 1913 with mounting thread M10 or 7 / 16-0 UNF to EN Power supply U H Supplied through bus Terminal voltage on transmitter V DC V DC in intrinsically-safe mode Separate 4 V power supply necessary - No Bus voltage Not Ex V With intrinsically-safe operation V Current consumption Basic current (max.) ma Startup current basic current - Yes Max. current in event of fault ma Fault disconnection electronics (FDE) available - Yes Siemens FI US Edition /59

60 Siemens AG 007 Transmitters for gage, absolute and differential pressure, flow and level DS III series for gage pressure SITRANS P, DS III series for gage pressure HART PROFIBUS PA or FOUNDATION Fieldbus Certificate and approvals Classification according to pressure equipment directive (DRGL 97/3/EC) graph 3 (sound engineering practice) For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of Article 3, para- Explosion protection Intrinsic safety "i" PTB 99 ATEX 1 - Identification Ex II 1/ G EEx ia/ib IIB/IIC T6 - Permissible ambient temperature C ( F) temperature class T4; C ( F) temperature class T5; C ( F) temperature class T6 - Connection To certified intrinsically-safe circuits with maximum values: U i = 30 V, I i = 100 ma, P i = 750 mw; R i = 300 Ω FISCO supply unit: U o = 17.5 V, I o = 380 ma, P o = 5.3 W Linear barrier: U o = 4 V, I o = 50 ma, P o = 1. W - Effective internal inductance/capacitance L i = 0.4 mh, C i = 6 nf L i = 7 µh, C i = 1.1 nf Explosion-proof "d" PTB 99 ATEX Identification Ex II 1/ G EEx d IIC T4/T6 - Permissible ambient temperature C ( F) temperature class T4; C ( F) temperature class T6 - Connection To circuits with values: U H = V DC To circuits with values: U H = V DC Dust explosion protection for zone 0 PTB 01 ATEX Identification Ex II 1 D IP65 T 10 C Ex II 1/ D IP65 T 10 C - Permissible ambient temperature C ( F) - Max.surface temperature 10 C (48 F) - Connection To certified intrinsically-safe circuits with maximum values: U i = 30 V, I i = 100 ma, P i = 750 mw, R i = 300 Ω FISCO supply unit: U o = 17.5 V, I o = 380 ma, P o = 5.3 W Linear barrier: U o = 4 V, I o = 50 ma, P o = 1. W - Effective internal inductance/capacitance L i = 0.4 mh, C i = 6 nf L i = 7 µh, C i = 1.1 nf Dust explosion protection for zone 1/ PTB 01 ATEX Identification Ex II D IP65 T 10 C - Connection To circuits with values: U H = V DC; P max = 1. W To circuits with values: U H = V DC; P max = 1. W Type of protection "n" (zone ) TÜV 01 ATEX 1696 X Planned - Identification Ex II 3 G EEx na L IIC T4/T5/T6 - Explosion protection to FM Certificate of Compliance Identification (XP/DIP) or (IS); (NI) CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; CL I, ZN 0/1 AEx ia IIC T4...T6; CL I, DIV, GP ABCD T4...T6; CL II, DIV, GP FG; CL III Explosion protection to CSA Certificate of Compliance Identification (XP/DIP) or (IS) CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; Ex ia IIC T4...T6; CL I, DIV, GP ABCD T4...T6; CL II, DIV, GP FG; CL III /60 Siemens FI US Edition

61 Transmitters for gage, absolute and differential pressure, flow and level DS III series for gage pressure HART communication HART communication Ω Protocol HART Version 5.x Software for computer SIMATIC PDM PROFIBUS PA communication Simultaneous communication with master class (max.) The address can be set using Cyclic data usage Output byte Input byte Internal preprocessing Device profile Function blocks Analog input - Adaptation to customer-specific process variables - Electrical damping T 63, adjustable 4 Configuration tool or local operation (standard setting address 16) 5 (one measuring value) or 10 (two measuring values) 0, 1, or (register operating mode and reset function for metering) PROFIBUS PA Profile for Process Control Devices Version 3.0, Class B Yes, linearly rising or falling characteristic s - Simulation function Input /Output - Failure mode Can be parameterized (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively Register (totalizer) Can be reset, preset, optional direction of counting, simulation function of register output - Failure mode Can be parameterized (summation with last good value, continuous summation, summation with incorrect value) - Limit monitoring One upper and lower warning limit and one alarm limit respectively Physical block 1 Transducer blocks Pressure transducer block - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Characteristics Max. 30 points - Square-rooted characteristic Yes for flow measurement - Gradual volume suppression Parameterizable and implementation point of square-root extraction - Simulation function for measured pressure value and sensor temperature Constant value or over parameterizable ramp function Siemens AG 007 Communication FOUNDATION Fieldbus Function blocks 3 function blocks analog input, 1 function block PID Analog input - Adaptation to customer-specific process variables - Electrical damping T 63, adjustable Yes, linearly rising or falling characteristic s - Simulation function Output/input (can be locked within the device with a bridge) - Failure mode Can be parameterized (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively - Square-rooted characteristic Yes for flow measurement PID Standard FF function block Physical block 1 Resource block Transducer blocks 1 transducer block Pressure with calibration, 1 transducer block LCD Pressure transducer block - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Simulation function: Measured pressure value, sensor temperature and electronics temperature Constant value or over parameterizable ramp function Siemens FI US Edition /61

62 Transmitters for gage, absolute and differential pressure, flow and level DS III series for gage pressure Selection and Ordering data SITRANS P pressure transmitters for gage pressure, series DS III HART Order No. 7 M F Y Measuring cell filling Measuring cell cleaning Silicone oil Standard } 1 Inert liquid 1) Grease-free 3 Span bar g ( psi g) } B bar g ( psi g) } C bar g ( psi g) } D bar g ( psi g) } E bar g ( psi g) } F bar g ( psi g) } G Wetted parts materials Seal diaphragm Process connection Stainless steel Stainless steel } A Hastelloy Stainless steel F) B Hastelloy Hastelloy F) C Version as diaphragm seal ) 3) Process connection Connection shank G½A to EN } 0 Female thread ½-14 NPT 1 Oval flange made of stainless steel - Mounting thread 7 / 16-0 UNF to EN Mounting thread M10 to DIN Mounting thread M1 to DIN Male thread M0 x 1,5 5 Male thread ½-14 NPT 6 Non-wetted parts materials Housing made of die-cast aluminium } 0 Housing stainless steel precision casting 4) 3 Version Standard version 1 International version, English label inscriptions, } documentation in 5 languages on CD Explosion protection Without A With ATEX, Type of protection: - "Intrinsic safety (EEx ia)" B - "Explosion-proof (EEx d)" 5) F) D - "Intrinsic safety and explosion-proof enclosure F) P (EEx ia + EEx d)" 6) - "Ex na/nl (zone )" E - "Intrinsic safety, explosion-proof enclosure and } R dust explosion protection (EEx ia + EEx d + F) Zone 1D/D)" 6) With FM + CSA, Type of protection: - "Intrinsic safety and explosion-proof F) N C (is + xp)" 5) Electrical connection / cable entry Screwed gland Pg 13.5 (adapter) 7) A Screwed gland M0x1.5 } B Screwed gland ½-14 NPT C Han 7D plug (plastic housing) incl. mating F) D connector 7) M1 connector (metall) 8) F Display Without (digital indicator hidden, setting: ma) } 1 With visible digital indicator, setting: ma 6 with customer-specific digital indicator 7 (setting as specified, Order code "Y1" or "Y" required) }Available ex stock Power supply units see "SITRANS I power supply units and isolation amplifiers". Siemens AG 007 Selection and Ordering data SITRANS P pressure transmitters for gage pressure, series DS III HART Power supply units see "SITRANS I power supply units and isolation amplifiers". Factory-mounting of shut-off valves and valve manifolds see page /16. Included in delivery of the device: Brief instructions (Leporello) CD-ROM with detailed documentation 1) For oxygen cleaning application, add Order code E10. ) When the manufacture s certificate M (calibration certificate) has to be ordered for transmitters with diaphragm seals, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. 3) Whe the acceptance test certificate 3.1 for transmitters with direct-connected diaphragm seals is ordered, this certificate must also be ordered with the corresponding seals. 4) Not together with Electrical connection Screwed gland Pg 13.5 and Han7D plug. 5) Without cable gland, with blanking plug 6) With enclosed cable gland EEx ia and blanking plug 7) Not together with type of protection "Explosion-proof" and type of protection "Ex na". 8) Cannot be used together with the following types of protection: "Explosion-proof" and "Intrinsic safety and explosion-proof" F) Subject to export regulations AL: 9I999, ECCN: N. Order No. 7 M F /6 Siemens FI US Edition

63 Selection and Ordering data Transmitters for gage, absolute and differential pressure, flow and level DS III series for gage pressure Order No. SITRANS P pressure transmitters for gage pressure DS III PA (PROFIBUS PA) series 7 M F DS III FF series (FOUNDATION Fieldbus) 7 M F Measuring cell filling Measuring cell cleaning Silicone oil Standard 1 Inert liquid 1) Grease-free 3 Nominal measuring range 1 bar g (14.5 psi g) F) B 4 bar g (58 psi g) F) C 16 bar g (3 psi g) D 63 bar g (914 psi g) E 160 bar g (30 psi g) F 400 bar g (580 psi g) G Wetted parts materials Seal diaphragm Process connection Stainless steel Stainless steel A Hastelloy Stainless steel B Hastelloy Hastelloy C ) 3) Version as diaphragm seal Y Process connection Connection shank G½A to EN Female thread ½-14 NPT 1 Oval flange made of stainless steel - Mounting thread 7 / 16-0 UNF to EN Mounting thread M10 to DIN Mounting thread M1 nach DIN Male thread M0 x 1,5 5 Male thread ½-14 NPT 6 Non-wetted parts materials Housing made of die-cast aluminium 0 Housing stainless steel precision casting 3 Version Standard version 1 International version, English label inscriptions, documentation in 5 languages on CD Explosion protection Without A With CENELEC, Type of protection: - "Intrinsic safety (EEx ia)" B - "Explosion-proof (EEx d)" 4) F) D - "Intrinsic safety and explosion-proof enclosure F) P (EEx ia + EEx d)" 5) - "Ex na/nl (zone )" E - "Intrinsic safety, explosion-proof enclosure and F) R dust explosion protection (EEx ia + EEx d + Zone 1D/D)" 6) (not for DS III FF) With FM + CSA, Type of protection: - "Intrinsic safety and explosion-proof F) N C (is + xp)" 5) Electrical connection / cable entry Screwed gland M0x1.5 B Screwed gland ½-14 NPT C Plug M1 (metal) 6) F Display Without (digital display hidden) 1 With visible digital indicator 6 With customer-specific digital indicator (setting 7 as specified, Order code "Y1" or required) Factory-mounting of shut-off valves and valve manifolds see page /16. The device is delivered together with brief instructions (Leporello) and a CD-ROM containing detailed documentation. Siemens AG 007 1) For oxygen cleaning application, add Order code E10. ) When the manufacture s certificate M (calibration certificate) has to be ordered for transmitters with diaphragm seals, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. 3) Whe the acceptance test certificate 3.1 for transmitters with direct-connected diaphragm seals is ordered, this certificate must also be ordered with the corresponding seals. 4) Without cable gland, with blanking plug. 5) With enclosed cable gland EEx ia and blanking plug. 6) Cannot be used together with the following types of protection: "Explosion-proof" and "Intrinsic safety and explosion-proof" F) Subject to export regulations AL: 9I999, ECCN: N. Siemens FI US Edition /63

64 Transmitters for gage, absolute and differential pressure, flow and level DS III series for gage pressure Selection and Ordering data Order code Further designs HART PA FF Add "-Z" to Order No. and specify Order code. Pressure transmitter with mounting bracket made of: Steel A01 Stainless steel A0 Plug Han 7D (metal, gray) A30 Han 8U (instead of Han 7D) A31 Cable sockets for M1 connectors (metal) A50 Rating plate inscription (instead of German) English B11 French B1 Spanish B13 Italian B14 English rating plate B1 Pressure units in inh O or psi Manufacturer's test certificate M (calibration certificate) 1) C11 To DIN 55350, Part 18 and to ISO 840 Acceptance test certificate ) C1 To EN Factory certificate C14 To EN "Functional Safety (SIL)" certificate C0 "PROFIsafe certificate and protocol C1 Setting of upper limit of output signal to D05.0 ma Manufacturer's declaration acc. to NACE D07 Type of protection IP68 D1 (not together with 7D/ Han 8U plug, cable gland Pg 13.5) Digital indicator alongside the input keys D7 (only together with the devices 7MF A.6 or -.A.7-Z, Y1 or Y + Y01) Supplied with oval flange D37 F) (1 item), PTFE packing and screws in thread of oval flange Use in or on zone 1D/D E01 (only together with type of protection "Intrinsic safety (EEx ia)") Use on zone 0 E0 (only together with type of protection "Intrinsic safety (EEx ia)") Oxygen cleaning application E10 (max. 160 bar g (30 psi g) for oxygen measurement and inert liquid) Explosion-proof "Intrinsic safety" to E5 INMETRO (Brazil) (only for transmitter 7MF B..) Explosion-proof "Intrinsic safety" to E55 NEPSI (China) (only for transmitter 7MF B..) Explosion protection "Explosion-proof" to E56 NEPSI (China) (only for transmitter 7MF D..) Explosion-proof "Zone " to NEPSI (China) E57 (only for transmitter 7MF E..) Siemens AG 007 Selection and Ordering data Order code Additional data Add "-Z" to Order No. and specify Order code. HART PA FF Measuring range to be set Y01 Specify in plain text (max. 5 digits): Y01:... up to... mbar, bar, kpa, MPa, psi Measuring point number (TAG No.) Y15 Max. 16 characters, specify in plain text: Y15:... Measuring point text Y16 Max. 7 characters, specify in plain text: Y16:... Entry of HART address (TAG) Y17 Max. 8 characters, specify in plain text: Y17:... Setting of pressure indication in pressure Y1 units Specify in plain text (standard setting: ma): Y1: mbar, bar, kpa, MPa, psi,... Note: The following pressure units can be selected: bar, mbar, mm H O *), inh O *), fth O *), mmhg, inhg, psi, Pa, kpa, MPa, g/cm, kg/cm, Torr, ATM oder % *) ref. temperature 0 C Setting of pressure indication in Y + non-pressure units Y01 Specify in plain text: Y:... up to... l/min, m 3 /h, m, USgpm,... (specification of measuring range in pressure units "Y01" is essential, unit with max. 5 characters) Preset bus address Y5 Specify in plain text: Y5:... Only "Y01", "Y1", "Y", "Y5" and "D05" can be factory preset = available Ordering example Item line: 7MF4033-1EA00-1AA7-Z B line: A01 + Y01 + Y1 C line: Y01: bar ( psi) C line: Y1: bar (psi) F) Subject to export regulations AL: 9I999, ECCN: N. 1) ) When the manufacture s certificate M (calibration certificate) has to be ordered for transmitters with diaphragm seals, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. Whe the acceptance test certificate 3.1 for transmitters with direct-connected diaphragm seals is ordered, this certificate must also be ordered with the corresponding seals. /64 Siemens FI US Edition

65 Dimensional drawings 15 (0.6) 74 (.9) Transmitters for gage, absolute and differential pressure, flow and level DS III series for gage pressure 144 (5.67) 51 (.0) 8 (1.1) 55 (0.6) Siemens AG 007 approx. 30 (1.) 100 (3.94) approx. 96 (3.78) 4) 6 50 (1.97) ø 80 (3.15) 0 (0.8) 1) 5 4 1) 117 (4.6) (6.7) 37 (9.3) 1 7 (.8) 68 (.7) 10 (4.7) 36,5 (1,44) 13 (4.8) min. 77 (3.0) 1 Process connection: - ½-14 NPT, - connection shank G½A or - oval flange Blanking plug 3 Electrical connection: - screwed gland Pg 13,5 (adapter) ) 3), - screwed gland M0x1,5 3), - screwed gland ½-14 NPT or ) 3) - Han 7D/ Han 8U plug 5) ø ( ) 4 Terminal side 5 Electronics side, digital display (longer overall length for cover with window) 6 Protective cover over keys 7 Mounting bracket (option) 8 Screw cover - safety bracket (only for type of protection "Explosion-proof enclosure", not shown in the drawing) (4.1) 1) Allow approx. 0 mm (0.79 inch) thread length to permit unscrewing ) Not with type of protection "explosion-proof enclosure" 3) Not with type of protection "FM + CSA [is + xp]" 4) 45 mm (1.8 inch) for Pg 13,5 with adapter 5) Minimum distance for rotation SITRANS P pressure transmitters, DS III HART series for gage pressure, dimensions in mm (inch) Siemens FI US Edition /65

66 Transmitters for gage, absolute and differential pressure, flow and level DS III series for gage pressure 15 (0.6) 74 (.9) 144 (5.67) 51 (.0) 55 (0.6) 8 (1.1) Siemens AG 007 approx. 30 (1.) 100 (3.94) 6 50 (1.97) ø 80 (3.15) 0 (0.8) 1) (4.6) 1) (6.7) 37 (9.3) 1 7 (.8) 68 (.7) 10 (4.7) 36,5 (1,44) 13 (4.8) 1 Process connection: - ½-14 NPT, - connection shank G½A or - oval flange Blanking plug 3 Electrical connection: - screwed gland M0x1,5 4), - screwed gland ½-14 NPT or 3) 4) - PROFIBUS plug M1 min. 77 (3.0) ) ø ( ) 4 Terminal side 5 Electronics side, digital display (longer overall length for cover with window) 6 Protective cover over keys 7 Mounting bracket (option) 8 Screw cover safety bracket (only for explosion-proof enclosure, not shown in the drawing) (4.1) 1) Allow approx. 0 mm (0.79 inch) thread length in addition ) Minimum distance for rotating 3) Not with type of protection "Explosion-proof enclosure". 4) Not with type of protection "FM + CSA". SITRANS P pressure transmitters, DS III PA and FF series for gage pressure, dimensions in mm (inch) /66 Siemens FI US Edition

67 Technical specifications Transmitters for gage, absolute and differential pressure, flow and level DS III series for gage pressure, with front-flush diaphragm SITRANS P, DS III series for gage pressure, with front-flush diaphragm Input Measured variable Spans (infinitely adjustable) or nominal measuring range and max. permissible test pressure HART Gage pressure Span bar g ( psi g) bar g ( psi g) bar g ( psi g) bar g ( psi g) Siemens AG 007 Max. perm. test pressure 6 bar g (87 psi g) 10 bar g (145 psi g) 3 bar g (464 psi g) 100 bar g (1450 psi g) PROFIBUS PA or FOUNDATION Fieldbus Nominal measuring range 1 bar g (14.5 psi g) 4 bar g (58 psi g) 16 bar g (3 psi g) 63 bar g (914 psi g) Max. perm. test pressure 6 bar g (87 psi g) 10 bar g (145 psi g) 3 bar g (464 psi g) 100 bar g (1450 psi g) Lower measuring limit Measuring cell with silicone oil filling 100 mbar a (1.45 psi a) Upper measuring limit 100% of max. span Output Output signal ma Digital PROFIBUS PA or FOUNDATION Fieldbus signal Lower limit (infinitely adjustable) 3.55 ma, factory preset to 3.84 ma - Upper limit (infinitely adjustable) 3 ma, factory preset to 0.5 ma or optionally - set to.0 ma Load Without HART communication R B (U H V)/0.03 A in Ω, - U H : Power supply in V With HART communication R B = Ω (SIMATIC PDM) or - R B = Ω (HART Communicator) Physical bus - IEC With polarity reversal protection - Yes Accuracy To EN Reference conditions Increasing characteristic, start-of-scale value 0 bar, stainless steel seal diaphragm, silicone oil filling, room temperature 5 C (77 F)) r: Span ratio (r = max. span/set span) Error in measurement and fixed-point setting (including hysteresis and repeatability) Linear characteristic 0,075% -r 10 (0.009 r )% - 10 < r 30 ( r )% - 30 < r 100 (0.005 r )% Long-term drift (temperature change ±30 C (0.5 r)% every 5 years 0.5% every 5 years (±54 F)) Influence of ambient temperature at C ( F) (0.08 r + 0.1)% 0,3% at C and C (0.1 r )%/10 K 0.5%/10 K ( F and F) Influence of mounting position 0.1 mbar g ( psi g) per 10 inclination Measured Value Resolution of nominal measuring range Influence of the medium temperature (only with front-flush diaphragm) Temperature difference between medium temperature and ambient temperature 3 mbar/10 K (0.04 psi/10 K) Siemens FI US Edition /67

68 Siemens AG 007 Transmitters for gage, absolute and differential pressure, flow and level DS III series for gage pressure, with front-flush diaphragm SITRANS P, DS III series for gage pressure, with front-flush diaphragm HART PROFIBUS PA or FOUNDATION Fieldbus Rated operating conditions Degree of protection (to EN 6059) IP65 Process temperature C ( F) Ambient conditions Ambient temperature C ( F) Storage temperature C ( F) Climatic class - Condensation Permissible Electromagnetic compatibility - Emitted interference and interference immunity To EN 6136 and NAMUR NE 1 Design Weight (without options) 1.5 kg ( 3.3 lb) Housing material Low copper die-cast aluminium, GD-AlSi1 or stainless steel precision casting, mat. No Wetted parts materials Stainless steel, mat. No /316L Measuring cell filling Silicone oil or inert filling liquid Power supply U H Supplied through bus Terminal voltage on transmitter V DC V DC in intrinsically-safe mode Separate 4 V power supply necessary - No Bus voltage Not Ex V With intrinsically-safe operation V Current consumption Basic current (max.) ma Startup current basic current - Yes Max. current in event of fault ma Fault disconnection electronics (FDE) available - Yes Certificate and approvals Classification according to pressure equipment directive (DRGL 97/3/EC) For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of Article 3, paragraph 3 (sound engineering practice) Sanitary version In the case of SITRANS P DSIII with 7MF413x front-flush diaphragm, selected connections comply with the requirements of EHEDG.. /68 Siemens FI US Edition

69 Transmitters for gage, absolute and differential pressure, flow and level DS III series for gage pressure, with front-flush diaphragm HART communication HART communication Ω Protocol HART Version 5.x Software for computer SIMATIC PDM PROFIBUS PA communication Simultaneous communication with master class (max.) The address can be set using Cyclic data usage Output byte Input byte Internal preprocessing Device profile Function blocks Analog input - Adaptation to customer-specific process variables - Electrical damping T 63, adjustable 4 Configuration tool or local operation (standard setting address 16) 5 (one measuring value) or 10 (two measuring values) 0, 1, or (register operating mode and reset function for metering) PROFIBUS PA Profile for Process Control Devices Version 3.0, Class B Yes, linearly rising or falling characteristic s - Simulation function Input /Output - Failure mode Can be parameterized (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively Register (totalizer) Can be reset, preset, optional direction of counting, simulation function of register output - Failure mode Can be parameterized (summation with last good value, continuous summation, summation with incorrect value) - Limit monitoring One upper and lower warning limit and one alarm limit respectively Physical block 1 Transducer blocks Pressure transducer block - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Characterizer Max. 30 points - Square-rooted characteristic Yes for flow measurement - Gradual volume suppression Parameterizable and implementation point of square-root extraction - Simulation function for measured pressure value and sensor temperature Constant value or over parameterizable ramp function Siemens AG 007 Communication FOUNDATION Fieldbus Function blocks 3 function blocks analog input, 1 function block PID Analog input - Adaptation to customer-specific process variables - Electrical damping T 63, adjustable Yes, linearly rising or falling characteristic s - Simulation function Output/input (can be locked within the device with a bridge) - Failure mode Can be parameterized (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively - Square-rooted characteristic Yes for flow measurement PID Standard FF function block Physical block 1 Resource block Transducer blocks 1 transducer block Pressure with calibration, 1 transducer block LCD Pressure transducer block - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Simulation function: Measured pressure value, sensor temperature and electronics temperature Constant value or over parameterizable ramp function Siemens FI US Edition /69

70 Transmitters for gage, absolute and differential pressure, flow and level DS III series for gage pressure, with front-flush diaphragm Selection and Ordering data Order No. SITRANS P pressure transmitters for gage pressure, front-flush membrane, series DS III HART F) 7 M F Measuring cell filling Measuring cell cleaning Silicone oil Standard 1 Inert liquid Grease-free 3 FDA compliant fill fluid Neobee oil Standard 4 Span bar g 1) ( psi g) 1) B bar g ( psi g) C bar g ( psi g) D bar g ( psi g) E Wetted parts materials Seal diaphragm Connection shank Stainless steel Stainless steel A Process connection Flange version with Order code M.., N.., R.. or 7 Q.. Non-wetted parts materials Housing made of die-cast aluminium 0 Housing stainless steel precision casting 3 Version Standard version 1 International version, English label inscriptions, documentation in 5 languages on CD Explosion protection Without A With ATEX, Type of protection: - "Intrinsic safety (EEx ia)" B - "Explosion-proof (EEx d)" ) D - "Intrinsic safety, explosion-proof enclosure and R dust explosion protection (EEx ia + EEx d + Zone 1D/D)" 3) With FM + CSA, Type of protection: - "Intrinsic safety and explosion-proof N C (is + xp)" ) (available soon) Electrical connection / cable entry Inner thread M0x1.5 B Female thread ½-14 NPT C M1 connectors (metal) 4) F Display without (digital indicator hidden, setting: ma) 1 with visible digital indication, setting: ma 6 with customer-specific digital indication (setting 7 as specified, Order code "Y1" or "Y" required) Power supply units see "SITRANS I power supply units and isolation amplifiers". Included in delivery of the device: Brief instructions (Leporello) CD-ROM with detailed documentation 1) Only with "Standard" process connection ) Without cable gland, with blanking plug. 3) With enclosed cable gland EEx ia and blanking plug. 4) Cannot be used together with the following types of protection: "Explosion-proof" and "Intrinsic safety and explosion-proof" F) Subject to export regulations AL: 9I999, ECCN: N. Siemens AG 007 Selection and Ordering data Order No. SITRANS P pressure transmitters for gage pressure, front-flush membrane DS III PA series (PROFIBUS PA) F) 7 M F DS III FF series (FOUNDATION Fieldbus) F) 7 M F Measuring cell filling Measuring cell cleaning Silicone oil Standard 1 Inert liquid Grease-free 3 FDA compliant fill fluid Neobee oil Standard 4 Nominal measuring range 1bar g 1) (14.5 psi g) 1) B 4 bar g (58 psi g) C 16 bar g (3 psi g) D 63 bar g (914 psi g) E Wetted parts materials Seal diaphragm Connection shank Stainless steel Stainless steel A Process connection Flange version with Order code M.., N.., R.. or 7 Q.. Non-wetted parts materials Housing made of die-cast aluminium 0 Housing stainless steel precision casting 3 Version Standard version 1 International version, English label inscriptions, documentation in 5 languages on CD Explosion protection Without A With ATEX, Type of protection: - "Intrinsic safety (EEx ia)" B - "Explosion-proof (EEx d)" ) D - "Intrinsic safety, explosion-proof enclosure and R dust explosion protection (EEx ia + EEx d + Zone 1D/D)" 3) With FM + CSA, Type of protection: - "Intrinsic safety and explosion-proof N C (is + xp)" ) (available soon) Electrical connection / cable entry Screwed gland M0x1.5 B Screwed gland ½-14 NPT C M1 connectors (metal) 4) F Display Without (digital display hidden) 1 With visible digital display 6 With customer-specific digital display (setting as 7 specified, Order code "Y1" or required) Included in delivery of the device: Brief instructions (Leporello) CD-ROM with detailed documentation 1) Only with "Standard" process connection ) Without cable gland, with blanking plug. 3) With enclosed cable gland EEx ia and blanking plug. 4) Cannot be used together with the following types of protection: "Explosion-proof" and "Intrinsic safety and explosion-proof" F) Subject to export regulations AL: 9I999, ECCN: N. /70 Siemens FI US Edition

71 Selection and Ordering data Transmitters for gage, absolute and differential pressure, flow and level DS III series for gage pressure, with front-flush diaphragm Order code Further designs HART PA FF Add "-Z" to Order No. and specify Order code. Cable sockets for M1 connectors (metal) A50 Rating plate inscription (instead of German) English B11 French B1 Spanish B13 Italian B14 English rating plate B1 Pressure units in inh O or psi Manufacturer's test certificate M (calibration certificate) To DIN 55350, Part 18 and to ISO 840 C11 Acceptance test certificate C1 To EN Factory certificate C14 To EN "PROFIsafe" certificate and protocol C1 Flanges to EN DN 5, PN 40 M11 DN 5, PN 100 M1 DN 40, PN 40 M13 DN 40, PN 100 M3 DN 50, PN 16 M04 DN 50, PN 40 M14 DN 80, PN 16 M06 DN 80, PN 40 M16 Flanges to ASME B16.5 Stainless steel flange 1" class 150 M40 Stainless steel flange 1½" class 150 M41 Stainless steel flange " class 150 M4 Stainless steel flange " class 300 M47 Stainless steel flange 3" class 150 M43 Stainless steel flange 3" class 300 M48 Stainless steel flange 4" class 150 M44 Stainless steel flange 4" class 300 M49 Threaded connection R04 G, flush-mounted Tank connection R10 TG 50/5, PN 40 Sanitary process connection according DIN (Dairy connection) DN 50, PN 5 N04 DN 80, PN 5 N06 Tri-Clamp connection according DIN 3676/ISO 85 DN 50/, PN 16 N14 DN 65/3, PN 10 N15 Varivent connection certified to EHEDG Type N = 68 for Varivent housing N8 DN and 1½"... 6", PN 40 Temperature decoupler up to 00 C 1) P00 for version with front-flush diaphragm Bio-Control (Neumo) sanitary connection certified to EHEDG DN 50, PN 16 Q53 DN 65, PN 16 Q54 Siemens AG 007 Selection and Ordering data Order code Further designs HART PA FF Add "-Z" to Order No. and specify Order code. Sanitary process connection to DRD 50 mm, PN 40 M3 Sanitary process connection to NEUMO Bio-Connect screw connection certified to EHEDG DN 50, PN 16 Q05 DN 65, PN 16 Q06 DN 80, PN 16 Q07 DN 100, PN 16 Q08 DN, PN 16 Q13 DN ½, PN 16 Q14 DN 3, PN 16 Q15 DN 4, PN 16 Q16 Sanitary process connection to NEUMO Bio-Connect flange connection certified to EHEDG DN 50, PN 16 Q3 DN 65, PN 16 Q4 DN 80, PN 16 Q5 DN 100, PN 16 Q6 DN, PN 16 Q31 DN ½, PN 16 Q3 DN 3, PN 16 Q33 DN 4, PN 16 Q34 Sanitary process connection to NEUMO Bio-Connect clamp connection certified to EHEDG DN 50, PN 16 Q39 DN 65, PN 10 Q40 DN 80, PN 10 Q41 DN 100, PN 10 Q4 DN ½, PN 16 Q48 DN 3, PN 10 Q49 DN 4, PN 10 Q50 Sanitary process connection to NEUMO Connect S flange connection certified to EHEDG DN 50, PN 16 Q63 DN 65, PN 10 Q64 DN 80, PN 10 Q65 DN 100, PN 10 Q66 DN, PN 16 Q7 DN ½, PN 10 Q73 DN 3, PN 10 Q74 DN 4, PN 10 Q75 1) The maximum temperatures of the medium depend on the respective cell fillings. Siemens FI US Edition /71

72 Transmitters for gage, absolute and differential pressure, flow and level DS III series for gage pressure, with front-flush diaphragm Selection and Ordering data Order code Additional data HART PA FF Add "-Z" to Order No. and specify Order code. Measuring range to be set Y01 Specify in plain text (max. 5 digits): Y01:... up to... mbar, bar, kpa, MPa, psi Measuring point number (TAG No.) Y15 Max. 16 characters, specify in plain text: Y15:... Measuring point text Y16 Max. 7 characters, specify in plain text: Y16:... Setting of pressure indicator in pressure Y1 units Specify in plain text (standard setting: ma): Y1: mbar, bar, kpa, MPa, psi,... Note: The following pressure units can be selected: bar, mbar, mm H O *), inh O *), fth O *), mmhg, inhg, psi, Pa, kpa, MPa, g/cm, kg/cm, Torr, ATM oder % *) ref. temperature 0 C Only "Y01" and "Y1" can be factory preset = available Ordering example Item line: 7MF4133-1DB0-1AB7-Z B line: A + Y01 + Y1 C line: Y01: bar ( psi) C line: Y1: bar (psi) Siemens AG 007 /7 Siemens FI US Edition

73 Dimensional drawings Siemens AG 007 Transmitters for gage, absolute and differential pressure, flow and level DS III series for gage pressure, with front-flush diaphragm SITRANS P pressure transmitters, DS III series for gage pressure, with front-flush diaphragm, dimensions in mm (inch) The diagram shows a SITRANS P DS III with an example of a flange. In this drawing the height is subdivided into H 1 and H. H 1 = Height of the SITRANS DS III up to a defined cross-section H = Height of the flange up to this defined cross-section Only the height H is indicated in the dimensions of the flanges. Flanges to EN and ASME Flanges to EN EN Flanges to ASME ASME B16.5 DN PN D H mm (4.5 ) Approx mm (5.5 ) 5 mm ( ) mm (5.9 ) mm (6.7 ) mm (6.5 ) mm (6.5 ) mm (7.9 ) mm (7.9 ) DN class D H mm (4.3 ) Approx mm (4.9 ) 5 mm ( ) 1½ mm (5.1 ) 1½ mm (6.1 ) mm (5.9 ) mm (6.5 ) mm (7.5 ) mm (8.1 ) mm (9.1 ) mm (10.0 ) NuG and pharmaceutical connections Connections to DIN DIN (Dairy connection) DN PN D H mm (3.6 ) Approx mm (5.0 ) 5 mm ( ) Tri-Clamp according DIN 3676 DN PN D H mm (.5 ) Approx mm (3.6 ) 5 mm ( ) Other connections Varivent connection DN PN D H mm (3.3 ) Approx. 5 mm ( ) Siemens FI US Edition /73

74 Siemens AG 007 Transmitters for gage, absolute and differential pressure, flow and level DS III series for gage pressure, with front-flush diaphragm Bio-Control connection Sanitary process connection to DRD DN PN D H mm (3.5 ) Approx mm (4.7 ) 5 mm ( ) DN PN D H mm (4.1 ) Approx. 5 mm ( ) Sanitary connection to NEUMO Bio-Connect S flange connection DN PN D H mm (4.9 ) Approx mm (5.7 ) 5 mm ( ) mm (6.1 ) mm (7.1 ) mm (4.9 ) ½ mm (5.3 ) mm (5.7 ) mm (7.1 ) Thread connection G to DIN 385 Sanitary process screw connection to NEUMO Bio-Connect DN PN D H mm (3.1 ) Approx. 5 mm ( ) DN PN D H mm (3. ) Approx mm (4.1 ) 5 mm ( ) mm (4.5 ) mm (5.7 ) 16 8 mm (3. ) ½ mm (4.1 ) mm (4.1 ) mm (5.7 ) Tank connection TG5/50 DN PN D H mm (.5 ) Approx. 63 mm (.5 ) Sanitary connection to NEUMO Bio-Connect flange connection DN PN D H mm (4.3 ) Approx mm (5.5 ) 5 mm ( ) mm (5.9 ) mm (6.9 ) mm (3.9 ) ½ mm (4.3 ) mm (5.5 ) mm (6.9 ) Sanitary connection to NEUMO Bio-Connect clamp connection DN PN D H ,4 mm (3.0 ) Approx ,9 mm (3.6 ) 5 mm ( ) mm (4. ) mm (4.7 ) mm (.5 ) ½ 16 77,4 mm (3.0 ) ,9 mm (3.6 ) mm (4.7 ) /74 Siemens FI US Edition

75 Technical specifications Transmitters for gage, absolute and differential pressure, flow and level DS III series for absolute pressure (gage construction) SITRANS P, DS III series for absolute pressure (gage construction) HART Input Measured variable Absolute pressure Spans (infinitely adjustable) or Span nominal measuring range and max. permissible test pressure mbar a ( psi a) mbar a ( psi a) mbar a ( psi a) bar a ( psi a) Lower measuring limit Measuring cell with silicone oil filling 0 mbar a (0 psi a) Upper measuring limit 100% of max. span Output Siemens AG 007 Max. perm. test pressure 6 bar a (87 psi a) 10 bar a (145 psi a) 30 bar a (435 psi a) 100 bar a (1450 psi a) PROFIBUS PA or FOUNDATION Fieldbus Nominal measuring range 50 mbar a (3.6 psi a) 1300 mbar a (18.9 psi a) 5 bar a (7.5 psi a) 30 bar a (435 psi a) Max. perm. test pressure 6 bar a (87 psi a) 10 bar a (145 psi a) 30 bar a (435 psi a) 100 bar a (1450 psi a) Output signal ma Digital PROFIBUS PA or FOUNDATION Fieldbus signal Lower limit (infinitely adjustable) 3.55 ma, factory preset to 3.84 ma - Upper limit (infinitely adjustable) 3 ma, factory preset to 0.5 ma or optionally set - to.0 ma Load Without HART communication R B (U H V)/0.03 A in Ω, - U H : Power supply in V With HART communication R B = Ω (SIMATIC PDM) or - R B = Ω (HART Communicator) Physical bus - IEC With polarity reversal protection - Yes Accuracy To EN Reference conditions Increasing characteristic, start-of-scale value 0 bar, stainless steel seal diaphragm, silicone oil filling, room temperature 5 C (77 F)) r: Span ratio (r = max. span / set span) Error in measurement and fixed-point setting (including hysteresis and repeatability) Linear characteristic 0.1% -r % - 10 < r 30 0.% Long-term drift (temperature change ±30 C (0.1 r)%/year 0.1%/year (±54 F)) Influence of ambient temperature at C ( F) (0.1 r +0.)% 0,3% at C and C (0.1 r )%/10 K 0.5%/10 K ( F and F) Measured Value Resolution of nominal measuring range Siemens FI US Edition /75

76 Siemens AG 007 Transmitters for gage, absolute and differential pressure, flow and level DS III series for absolute pressure (gage construction) SITRANS P, DS III series for absolute pressure (gage construction) HART PROFIBUS PA or FOUNDATION Fieldbus Rated operating conditions Degree of protection (to EN 6059) IP65 Process temperature Measuring cell with silicone oil filling C ( F) Measuring cell with inert filling liquid C ( F) In conjunction with dust explosion protection C ( F) Ambient conditions Ambient temperature - Digital indicators C ( F) Storage temperature C ( F) Climatic class - Condensation Permissible Electromagnetic compatibility - Emitted interference and interference immunity To EN 6136 and NAMUR NE 1 Design Weight (without options) 1.5 kg ( 3.3 lb) Housing material Low copper die-cast aluminium, GD-AlSi1 or stainless steel precision casting, mat. No Wetted parts materials Connection shank Stainless steel, mat. No /316L or Hastelloy C4, mat. No Oval flange Stainless steel, mat. No /316L Seal diaphragm Stainless steel, mat. No /316L or Hastelloy C76, mat. No Measuring cell filling Silicone oil or inert filling liquid (max. 160 bar a (30 psi a) with oxygen measurement) Process connection Connection shank G½A to DIN EN 837-1, female thread ½ -14 NPT or oval flange (PN 160 (MWP 30 psi a)) to DIN 1913 with mounting thread M10 or 7 / 16-0 UNF to EN Power supply U H Supplied through bus Terminal voltage on transmitter V DC V DC in intrinsically-safe mode Separate 4 V power supply necessary - No Bus voltage Not Ex V With intrinsically-safe operation V Current consumption Basic current (max.) ma Startup current basic current - Yes Max. current in event of fault ma Fault disconnection electronics (FDE) available - Yes /76 Siemens FI US Edition

77 Siemens AG 007 Transmitters for gage, absolute and differential pressure, flow and level DS III series for absolute pressure (gage construction) SITRANS P, DS III series for absolute pressure (gage construction) HART Certificate and approvals Classification according to pressure equipment directive (DRGL 97/3/EC) Explosion protection For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of Article 3, paragraph 3 (sound engineering practice) Intrinsic safety "i" PTB 99 ATEX 1 - Identification Ex II 1/ G EEx ia/ib IIB/IIC T6 - Permissible ambient temperature C ( F) temperature class T4; C ( F) temperature class T5; C ( F) temperature class T6 - Connection To certified intrinsically-safe circuits with maximum values: U i = 30 V, I i = 100 ma, P i = 750 mw; R i = 300 Ω FISCO supply unit: U o = 17.5 V, I o = 380 ma, P o = 5.3 W Linear barrier: U o = 4 V, I o = 50 ma, P o = 1. W - Effective internal inductance/capacitance L i = 0.4 mh, C i = 6 nf L i = 7 µh, C i = 1.1 nf Explosion-proof "d" PTB 99 ATEX Identification Ex II 1/ G EEx d IIC T4/T6 - Permissible ambient temperature C ( F) temperature class T4; C ( F) temperature class T6 - Connection To circuits with values: U H = V DC To circuits with values: U H = V DC Dust explosion protection for zone 0 PTB 01 ATEX Identification Ex II 1 D IP65 T 10 C Ex II 1/ D IP65 T 10 C - Permissible ambient temperature C ( F) - Max.surface temperature 10 C (48 F) - Connection To certified intrinsically-safe circuits with maximum values: U i = 30 V, I i = 100 ma, P i = 750 mw, R i = 300 Ω FISCO supply unit: U o = 17.5 V, I o = 380 ma, P o = 5.3 W Linear barrier: U o = 4 V, I o = 50 ma, P o = 1. W - Effective internal inductance/capacitance L i = 0.4 mh, C i = 6 nf L i = 7 µh, C i = 1.1 nf Dust explosion protection for zone 1/ PTB 01 ATEX Identification Ex II D IP65 T 10 C - Connection To circuits with values: U H = V DC; P max = 1. W PROFIBUS PA or FOUNDATION Fieldbus To circuits with values: U H = V DC; P max = 1. W Type of protection "n" (zone ) TÜV 01 ATEX 1696 X Planned - Identification Ex II 3 G EEx na L IIC T4/T5/T6 - Explosion protection to FM Certificate of Compliance Identification (XP/DIP) or (IS); (NI) CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; CL I, ZN 0/1 AEx ia IIC T4...T6; CL I, DIV, GP ABCD T4...T6; CL II, DIV, GP FG; CL III Explosion protection to CSA Certificate of Compliance Identification (XP/DIP) or (IS) CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; Ex ia IIC T4...T6; CL I, DIV, GP ABCD T4...T6; CL II, DIV, GP FG; CL III Siemens FI US Edition /77

78 Transmitters for gage, absolute and differential pressure, flow and level DS III series for absolute pressure (gage construction) HART communication HART communication Ω Protocol HART Version 5.x Software for computer SIMATIC PDM PROFIBUS PA communication Simultaneous communication with master class (max.) The address can be set using Cyclic data usage Output byte Input byte Internal preprocessing Device profile Function blocks Analog input - Adaptation to customer-specific process variables - Electrical damping T 63, adjustable 4 Configuration tool or local operation (standard setting address 16) 5 (one measuring value) or 10 (two measuring values) 0, 1, or (register operating mode and reset function for metering) PROFIBUS PA Profile for Process Control Devices Version 3.0, Class B Yes, linearly rising or falling characteristic s - Simulation function Input /Output - Failure mode Can be parameterized (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively Register (totalizer) Can be reset, preset, optional direction of counting, simulation function of register output - Failure mode Can be parameterized (summation with last good value, continuous summation, summation with incorrect value) - Limit monitoring One upper and lower warning limit and one alarm limit respectively Physical block 1 Transducer blocks Pressure transducer block - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Characterizer Max. 30 points - Square-rooted characteristic Yes for flow measurement - Gradual volume suppression Parameterizable and implementation point of square-root extraction - Simulation function for measured pressure value and sensor temperature Constant value or over parameterizable ramp function Siemens AG 007 Communication FOUNDATION Fieldbus Function blocks 3 function blocks analog input, 1 function block PID Analog input - Adaptation to customer-specific process variables - Electrical damping T 63, adjustable Yes, linearly rising or falling characteristic s - Simulation function Output/input (can be locked within the device with a bridge) - Failure mode Can be parameterized (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively - Square-rooted characteristic Yes for flow measurement PID Standard FF function block Physical block 1 Resource block Transducer blocks 1 transducer block Pressure with calibration, 1 transducer block LCD Pressure transducer block - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Simulation function: Measured pressure value, sensor temperature and electronics temperature Constant value or over parameterizable ramp function /78 Siemens FI US Edition

79 Selection and Ordering data Transmitters for gage, absolute and differential pressure, flow and level DS III series for absolute pressure (gage construction) Order No. SITRANS P pressure transmitters for absolute F) 7 M F pressure, from the pressure series DS III HART Measuring cell filling Measuring cell cleaning Silicone oil Standard 1 Inert liquid 1) Grease-free 3 Span mbar a ( psi a) D mbar a ( psi a) F bar a ( psi a) G bar a ( psi a) H Wetted parts materials Seal diaphragm Process connection Stainless steel Stainless steel A Hastelloy Stainless steel B Hastelloy Hastelloy C Version for diaphragm seal )3)4) Y Process connection Connection shank G½A to EN Female thread ½-14 NPT 1 Oval flange made of stainless steel - Mounting thread 7 / 16-0 UNF to EN Mounting thread M10 to DIN Male thread M0 x 1,5 5 Male thread ½-14 NPT 6 Non-wetted parts materials Housing made of die-cast aluminium 0 Housing stainless steel precision casting 5) 3 Version Standard version 1 International version, English label inscriptions, documentation in 5 languages on CD Explosion protection Without A With ATEX, Type of protection: - "Intrinsic safety (EEx ia)" B - "Explosion-proof (EEx d)" 6) D - "Intrinsic safety and explosion-proof enclosure P (EEx ia + EEx d)" 7) -"Ex na/nl (zone )" E - "Intrinsic safety, explosion-proof enclosure and R dust explosion protection (EEx ia + EEx d + Zone 1D/D)" 7) With FM + CSA, Type of protection: - "Intrinsic safety and explosion-proof N C (is + xp)" 6) Electrical connection / cable entry Screwed gland Pg ) A Screwed gland M0x1.5 B Screwed gland ½-14 NPT C Han 7D plug (plastic housing) incl. mating D connector 8) Plug M1 (metal) 9) F Display Without (digital indicator hidden, setting: ma) 1 With visible digital indicator 6 With customer-specific digital indicator (setting 7 as specified, Order code "Y1" or required) Power supply units see "SITRANS I power supply units and isolation amplifiers". Factory-mounting of shut-off valves and valve manifolds see page /16. Included in delivery of the device: Brief instructions (Leporello) CD-ROM with detailed documentation Siemens AG 007 1) For oxygen cleaning application, add Order code E10. ) Version 7MF433-1DY... only up to max. span 00 mbar a (.9 psi a) 3) When the manufacture s certificate M (calibration certificate) has to be ordered for transmitters with diaphragm seals, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. 4) Whe the acceptance test certificate 3.1 for transmitters with direct-connected diaphragm seals is ordered, this certificate must also be ordered with the corresponding seals. 5) Not together with Electrical connection Screwed gland Pg 13.5 and Han7D plug. 6) Without cable gland, with blanking plug. 7) With enclosed cable gland EEx ia and blanking plug. 8) Not together with type of protection "Explosion-proof" and type of protection "Ex na". 9) Not together with types of protection "Explosion-proof" or "Intrinsic safety and explosion-proof" F) Subject to export regulations AL: 9I999, ECCN: N. Siemens FI US Edition /79

80 Transmitters for gage, absolute and differential pressure, flow and level DS III series for absolute pressure (gage construction) Selection and Ordering data Order No. SITRANS P pressure transmitters for absolute pressure (from the gage pressure series) DS III PA series (PROFIBUS PA) F) 7 M F DS III FF series (FOUNDATION Fieldbus) F) 7 M F Measuring cell filling Measuring cell cleaning Silicone oil Standard 1 Inert liquid 1) Grease-free 3 Nominal measuring range 50 mbar a (3.63 psi a) D 1300 mbar a (18.9 psi a) F 5 bar a (7.5 psi a) G 30 bar a (435 psi a) H Wetted parts materials Seal diaphragm Process connection Stainless steel Stainless steel A Hastelloy Stainless steel B Hastelloy Hastelloy C Version as diaphragm seal )3)4) Y Process connection Connection shank G½A to EN Female thread ½-14 NPT 1 Oval flange made of stainless steel - Mounting thread 7 / 16-0 UNF to EN Mounting thread M10 to DIN Male thread M0 x 1,5 5 Male thread ½-14 NPT 6 Non-wetted parts materials Housing made of die-cast aluminium 0 Housing stainless steel precision casting 3 Version Standard version 1 International version, English label inscriptions, documentation in 5 languages on CD Explosion protection Without A With CENELEC, Type of protection: - "Intrinsic safety (EEx ia)" B - "Explosion-proof (EEx d)" 5) D - "Intrinsic safety and explosion-proof enclosure P (EEx ia + EEx d)" 6) - "Ex na/nl (zone )" E - "Intrinsic safety, explosion-proof enclosure and R dust explosion protection (EEx ia + EEx d + Zone 1D/D)" 6) (not for DS III FF) With FM + CSA, Type of protection: - "Intrinsic safety and explosion-proof N C (is + xp)" 5) Electrical connection / cable entry Screwed gland M0x1.5 B Screwed gland ½-14 NPT C Plug M1 incl. mating connector 7) F Display Without (digital display hidden) 1 With visible digital indicator 6 With customer-specific digital indicator (setting 7 as specified, Order code "Y1" or required) Factory-mounting of shut-off valves and valve manifolds see page /16. Included in delivery of the device: Brief instructions (Leporello) CD-ROM with detailed documentation Siemens AG 007 1) For oxygen cleaning application, add Order code E10. ) Version 7MF433-1DY... only up to max. span 00 mbar a (.9 psi a). 3) When the manufacture s certificate M (calibration certificate) has to be ordered for transmitters with diaphragm seals, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. 4) Whe the acceptance test certificate 3.1 for transmitters with direct-connected diaphragm seals is ordered, this certificate must also be ordered with the corresponding seals. 5) Without cable gland, with blanking plug. 6) With enclosed cable gland EEx ia and blanking plug. 7) Not together with types of protection "Explosion-proof" or "Intrinsic safety and explosion-proof" F) Subject to export regulations AL: 9I999, ECCN: N. /80 Siemens FI US Edition

81 Selection and Ordering data Transmitters for gage, absolute and differential pressure, flow and level DS III series for absolute pressure (gage construction) Order code Further designs HART PA FF Add "-Z" to Order No. and specify Order code. Pressure transmitter with mounting bracket made of: Steel A01 Stainless steel A0 Plug Han 7D (metal, gray) A30 Han 8U (instead of Han 7D) A31 Cable sockets for M1 connectors (metal) A50 Rating plate inscription (instead of German) English B11 French B1 Spanish B13 Italian B14 English rating plate B1 Pressure units in inh O or psi Manufacturer's test certificate M C11 (calibration certificate) 1) To DIN 55350, Part 18 and to ISO 840 Acceptance test certificate ) C1 To EN Factory certificate C14 To EN "Functional Safety (SIL)" certificate C0 "PROFIsafe" certificate and protocol C1 Setting of upper limit of output signal to D05.0 ma Manufacturer's declaration acc. to NACE D07 Type of protection IP68 D1 (not together with Han 7D / Han 8U plug, Pg 13.5 screwed gland) Digital indicator alongside the input keys D7 (only together with the devices 7MF A.6 or -.A.7-Z, Y1 or Y + Y01). Supplied with oval flange D37 (1 item), PTFE packing and screws in thread of oval flange Use in or on zone 1D/D E01 (only together with type of protection "Intrinsic safety (EEx ia)") Use on zone 0 E0 (only together with type of protection "Intrinsic safety (EEx ia)") Oxygen cleaning application E10 (max. 160 bar a (30 psi a) with oxygen measurement and inert liquid) Explosion-proof "Intrinsic safety" to E5 INMETRO (Brazil) (only for transmitter 7MF B..) Explosion-proof "Intrinsic safety" to NEPSI E55 (China) (only for transmitter 7MF B..) Explosion protection "Explosion-proof" to E56 NEPSI (China) (only for transmitter 7MF D..) Explosion-proof "Zone " to NEPSI (China) E57 (only for transmitter 7MF E..) Siemens AG 007 Selection and Ordering data Order code Additional data HART PA FF Add "-Z" to Order No. and specify Order code. Measuring range to be set Y01 Specify in plain text (max. 5 digits): Y01:... up to... mbar, bar, kpa, MPa, psi Measuring point number (TAG No.) Y15 Max. 16 characters, specify in plain text: Y15:... Measuring point text Y16 Max. 7 characters, specify in plain text: Y16:... Entry of HART address (TAG) Y17 Max. 8 characters, specify in plain text: Y17:... Setting of pressure indication in pressure Y1 units Specify in plain text (standard setting: ma): Y1: mbar, bar, kpa, MPa, psi,... Note: The following pressure units can be selected: bar, mbar, mm H O *), inh O *), fth O *), mmhg, inhg, psi, Pa, kpa, MPa, g/cm, kg/cm, Torr, ATM oder % *) ref. temperature 0 C Setting of pressure indication in Y + non-pressure units Y01 Specify in plain text: Y:... up to... l/min, m 3 /h, m, USgpm,... (specification of measuring range in pressure units "Y01" is essential, unit with max. 5 characters) Preset bus address Y5 Specify in plain text: Y5:... Only "Y01", "Y1", "Y", "Y5" and "D05" can be factory preset = available 1) ) When the manufacture s certificate M (calibration certificate) has to be ordered for transmitters with diaphragm seals, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. Whe the acceptance test certificate 3.1 for transmitters with direct-connected diaphragm seals is ordered, this certificate must also be ordered with the corresponding seals. Siemens FI US Edition /81

82 Transmitters for gage, absolute and differential pressure, flow and level DS III series for absolute pressure (gage construction) Dimensional drawings 15 (0.6) 74 (.9) 144 (5.67) 51 (.0) 55 (0.6) 8 (1.1) Siemens AG 007 approx. 30 (1.) 100 (3.94) approx. 96 (3.78) 4) 6 50 (1.97) ø 80 (3.15) 0 (0.8) 1) 5 4 1) 117 (4.6) (6.7) 37 (9.3) 1 7 (.8) 68 (.7) 10 (4.7) 36,5 (1,44) 13 (4.8) min. 77 (3.0) 1 Process connection: - ½-14 NPT, - connection shank G½A or - oval flange Blanking plug 3 Electrical connection: - screwed gland Pg 13,5 (adapter) ) 3), - screwed gland M0x1,5 3), - screwed gland ½-14 NPT or ) 3) - Han 7D/ Han 8U plug 5) ø ( ) 4 Terminal side 5 Electronics side, digital display (longer overall length for cover with window) 6 Protective cover over keys 7 Mounting bracket (option) 8 Screw cover - safety bracket (only for type of protection "Explosion-proof enclosure", not shown in the drawing) (4.1) 1) Allow approx. 0 mm (0.79 inch) thread length to permit unscrewing ) Not with type of protection "explosion-proof enclosure" 3) Not with type of protection "FM + CSA [is + xp]" 4) 45 mm (1.8 inch) for Pg 13,5 with adapter 5) Minimum distance for rotation SITRANS P pressure transmitters, DS III HART series for absolute pressure, from the pressure series, dimensions in mm (inch) /8 Siemens FI US Edition

83 15 (0.6) 74 (.9) Transmitters for gage, absolute and differential pressure, flow and level DS III series for absolute pressure (gage construction) 144 (5.67) 51 (.0) 8 (1.1) 55 (0.6) Siemens AG 007 approx. 30 (1.) 100 (3.94) 6 ø 80 (3.15) 50 (1.97) 0 (0.8) 1) (4.6) 1) (6.7) 37 (9.3) 1 7 (.8) 68 (.7) 10 (4.7) 36,5 (1,44) 13 (4.8) 1 Process connection: - ½-14 NPT, - connection shank G½A or - oval flange Blanking plug 3 Electrical connection: - screwed gland M0x1,5 4), - screwed gland ½-14 NPT or 3) 4) - PROFIBUS plug M1 min. 77 (3.0) ) ø ( ) 4 Terminal side 5 Electronics side, digital display (longer overall length for cover with window) 6 Protective cover over keys 7 Mounting bracket (option) 8 Screw cover safety bracket (only for explosion-proof enclosure, not shown in the drawing) (4.1) 1) Allow approx. 0 mm (0.79 inch) thread length in addition ) Minimum distance for rotating 3) Not with type of protection "Explosion-proof enclosure". 4) Not with type of protection "FM + CSA". SITRANS P pressure transmitters, DS III PA and FF series for absolute pressure, from the pressure series, dimensions in mm (inch) Siemens FI US Edition /83

84 Transmitters for gage, absolute and differential pressure, flow and level DS III series for absolute pressure (differential construction) Technical specifications SITRANS P, DS III series for absolute pressure (differential construction) HART Input Measured variable Absolute pressure pressure Spans (infinitely adjustable) or Span Maximum working pressure nominal measuring range and max. permissible working pressure mbar a ( psi a) mbar a ( psi a) mbar a ( psi a) bar a ( psi a) bar a ( psi a) Siemens AG bar a (464 psi a) 3 bar a (464 psi a) 3 bar a (464 psi a) 160 bar a (30 psi a) 160 bar a (30 psi a) (for connection thread M10 and 7 / 16-0 UNF in the process flanges) PROFIBUS PA or FOUNDATION Fieldbus Nominal measuring range 50 mbar a (3.6 psi a) 1300 bar a (18.9 psi a) 5 bar a (7.5 psi a) 30 bar a (435 psi a) 100 bar a (1450 psi a) Maximum working pressure 3 bar a (464 psi a) 3 bar a (464 psi a) 3 bar a (464 psi a) 160 bar a (30 psi a) 160 bar a (30 psi a) (for connection thread M10 and 7 / 16-0 UNF in the process flanges) Lower measuring limit Measuring cell with silicone oil filling 0 mbar a (0 psi a) Upper measuring limit 100% of max. span Output Output signal ma Digital PROFIBUS PA or FOUNDATION Fieldbus signal Lower limit (infinitely adjustable) 3.55 ma, factory preset to 3.84 ma - Upper limit (infinitely adjustable) 3 ma, factory preset to 0.5 ma or optionally set - to.0 ma Load Without HART communication R B (U H V)/0.03 A in Ω, - U H : Power supply in V With HART communication R B = Ω (SIMATIC PDM) or - R B = Ω (HART Communicator) Physical bus - IEC With polarity reversal protection - Yes Accuracy To EN Reference conditions Increasing characteristic, start-of-scale value 0 bar, stainless steel seal diaphragm, silicone oil filling, room temperature 5 C (77 F)) r: Span ratio (r = max. span / set span) Error in measurement and fixed-point setting (including hysteresis and repeatability) Linear characteristic 0.1% -r % - 10 < r 30 0.% Long-term drift (temperature change ± 30 C (0.1 r)%/year 0.1%/year (± 54 F)) Influence of ambient temperature at C ( F) (0.1 r +0.)% 0.3% at C and C (0.1 r )%/10 K 0.5%/10 K ( F and F) Measured Value Resolution of nominal measuring range /84 Siemens FI US Edition

85 Siemens AG 007 Transmitters for gage, absolute and differential pressure, flow and level DS III series for absolute pressure (differential construction) SITRANS P, DS III series for absolute pressure (differential construction) HART Rated operating conditions PROFIBUS PA or FOUNDATION Fieldbus Degree of protection (to EN 6059) IP65 Process temperature Measuring cell with silicone oil filling C ( F) Measuring cell with inert filling liquid C ( F) In conjunction with dust explosion protection C ( F) Ambient conditions Ambient temperature - Digital indicators C ( F) Storage temperature C ( F) Climatic class - Condensation Permissible Electromagnetic compatibility - Emitted interference and interference immunity To EN 6136 and NAMUR NE 1 Design Weight (without options) 4.5 kg ( 9.9 lb) Housing material Low copper die-cast aluminium, GD-AlSi1 or stainless steel precision casting, mat. No Wetted parts materials Seal diaphragm Stainless steel, mat. No /316L or Hastelloy C76, mat. No..4819, Monel, mat. No..4360, tantalum or gold Process flanges and sealing screw Stainless steel, mat. No , Hastelloy C4, mat. No or Monel, mat. No O-Ring FPM (Viton) or optionally: PTFE, FEP, FEPM and NBR Measuring cell filling Silicone oil or inert filling liquid (max. 160 bar (30 psi a) with oxygen measurement) Process connection ¼-18 NPT and flange connection to DIN 1913 with mounting thread M10 to DIN 1913 or 7 / 16-0 UNF to EN Power supply U H Terminal voltage on transmitter V DC V DC in intrinsically-safe mode Separate 4 V power supply necessary - No Bus voltage Not Ex V With intrinsically-safe operation V Current consumption Basic current (max.) ma Startup current basic current - Yes Max. current in event of fault ma Fault disconnection electronics (FDE) available - Yes Supplied through bus - Siemens FI US Edition /85

86 Siemens AG 007 Transmitters for gage, absolute and differential pressure, flow and level DS III series for absolute pressure (differential construction) SITRANS P, DS III series for absolute pressure (differential construction) HART PROFIBUS PA or FOUNDATION Fieldbus Certificate and approvals Classification according to pressure equipment directive (DRGL 97/3/EC) graph 3 (sound engineering practice) For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of Article 3, para- Explosion protection Intrinsic safety "i" PTB 99 ATEX 1 - Identification Ex II 1/ G EEx ia/ib IIB/IIC T6 - Permissible ambient temperature C ( F) temperature class T4; C ( F) temperature class T5; C ( F) temperature class T6 - Connection To certified intrinsically-safe circuits with maximum values: U i = 30 V, I i = 100 ma, P i = 750 mw; R i = 300 Ω FISCO supply unit: U o = 17.5 V, I o = 380 ma, P o = 5.3 W Linear barrier: U o = 4 V, I o = 50 ma, P o = 1. W - Effective internal inductance/capacitance L i = 0.4 mh, C i = 6 nf L i = 7 µh, C i = 1.1 nf Explosion-proof "d" PTB 99 ATEX Identification Ex II 1/ G EEx d IIC T4/T6 - Permissible ambient temperature C ( F) temperature class T4; C ( F) temperature class T6 - Connection To circuits with values: U H = V DC To circuits with values: U H = V DC Dust explosion protection for zone 0 PTB 01 ATEX Identification Ex II 1 D IP65 T 10 C Ex II 1/ D IP65 T 10 C - Permissible ambient temperature C ( F) - Max.surface temperature 10 C (48 F) - Connection To certified intrinsically-safe circuits with maximum values: U i = 30 V, I i = 100 ma, P i = 750 mw, R i = 300 Ω FISCO supply unit: U o = 17.5 V, I o = 380 ma, P o = 5.3 W Linear barrier: U o = 4 V, I o = 50 ma, P o = 1. W - Effective internal inductance/capacitance L i = 0.4 mh, C i = 6 nf L i = 7 µh, C i = 1.1 nf Dust explosion protection for zone 1/ PTB 01 ATEX Identification Ex II D IP65 T 10 C - Connection To circuits with values: U H = V DC; P max = 1. W To circuits with values: U H = V DC; P max = 1. W Type of protection "n" (zone ) TÜV 01 ATEX 1696 X Planned - Identification Ex II 3 G EEx na L IIC T4/T5/T6 - Explosion protection to FM Certificate of Compliance Identification (XP/DIP) or (IS); (NI) CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; CL I, ZN 0/1 AEx ia IIC T4...T6; CL I, DIV, GP ABCD T4...T6; CL II, DIV, GP FG; CL III Explosion protection to CSA Certificate of Compliance Identification (XP/DIP) or (IS) CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; Ex ia IIC T4...T6; CL I, DIV, GP ABCD T4...T6; CL II, DIV, GP FG; CL III /86 Siemens FI US Edition

87 Transmitters for gage, absolute and differential pressure, flow and level DS III series for absolute pressure (differential construction) HART communication HART communication Ω Protocol HART Version 5.x Software for computer SIMATIC PDM PROFIBUS PA communication Simultaneous communication with master class (max.) The address can be set using Cyclic data usage Output byte Input byte Internal preprocessing Device profile Function blocks Analog input - Adaptation to customer-specific process variables - Electrical damping T 63, adjustable 4 Configuration tool or local operation (standard setting address 16) 5 (one measuring value) or 10 (two measuring values) 0, 1, or (register operating mode and reset function for metering) PROFIBUS PA Profile for Process Control Devices Version 3.0, Class B Yes, linearly rising or falling characteristic s - Simulation function Input /Output - Failure mode Can be parameterized (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively Register (totalizer) Can be reset, preset, optional direction of counting, simulation function of register output - Failure mode Can be parameterized (summation with last good value, continuous summation, summation with incorrect value) - Limit monitoring One upper and lower warning limit and one alarm limit respectively Physical block 1 Transducer blocks Pressure transducer block - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Characterizer Max. 30 points - Square-rooted characteristic Yes for flow measurement - Gradual volume suppression Parameterizable and implementation point of square-root extraction - Simulation function for measured pressure value and sensor temperature Constant value or over parameterizable ramp function Siemens AG 007 Communication FOUNDATION Fieldbus Function blocks 3 function blocks analog input, 1 function block PID Analog input - Adaptation to customer-specific process variables - Electrical damping T 63, adjustable Yes, linearly rising or falling characteristic s - Simulation function Output/input (can be locked within the device with a bridge) - Failure mode Can be parameterized (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively - Square-rooted characteristic Yes for flow measurement PID Standard FF function block Physical block 1 Resource block Transducer blocks 1 transducer block Pressure with calibration, 1 transducer block LCD Pressure transducer block - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Simulation function: Measured pressure value, sensor temperature and electronics temperature Constant value or over parameterizable ramp function Siemens FI US Edition /87

88 Transmitters for gage, absolute and differential pressure, flow and level DS III series for absolute pressure (differential construction) Selection and Ordering data Order No. SITRANS P pressure transmitters for absolute F) 7 M F pressure, from the differential pressure, series DS III HART Measuring cell filling Measuring cell cleaning Silicone oil Standard 1 Inert liquid 1) Grease-free 3 Span mbar a ( psi a) E) D mbar a ( psi a) E) F bar a ( psi a) E) G bar a ( psi a) H bar a ( psi a) K E Wetted parts materials Seal diaphragm Parts of measuring cell Stainless steel Stainless steel A Hastelloy Stainless steel B Hastelloy Hastelloy C Tantalum Tantalum E Monel Monel E) H Gold Gold L Version for diaphragm seal )3)4) Y Process connection Female thread ¼-18 NPT with flange connection Sealing screw opposite process connection - Mounting thread M10 to DIN Mounting thread 7 / 16-0 UNF to EN Vent on side of process flange 5) - Mounting thread M10 to DIN Mounting thread 7 / 16-0 UNF to EN Non-wetted parts materials Process flange screws Electronics housing Stainless steel Die-cast aluminium Stainless steel Stainless steel precision 3 casting 6) Version Standard version 1 International version, English label inscriptions, documentation in 5 languages on CD Explosion protection Without A With ATEX, Type of protection: - "Intrinsic safety (EEx ia)" B - "Explosion-proof (EEx d)" 7) D - "Intrinsic safety and explosion-proof enclosure P (EEx ia + EEx d)" 8) - "Ex na/nl (zone )" E - "Intrinsic safety, explosion-proof enclosure and R dust explosion protection (EEx ia + EEx d + Zone 1D/D)" 8) With FM + CSA, Type of protection: - "Intrinsic safety and explosion-proof N C (is + xp)" 7) Electrical connection / cable entry Screwed gland Pg ) A Screwed gland M0x1.5 B Screwed gland ½-14 NPT C Han 7D plug (plastic housing) incl. mating D connector 9) Plug M1 (metal) 10) F Siemens AG 007 Selection and Ordering data Order No. SITRANS P pressure transmitters for absolute F) 7 M F pressure, from the differential pressure, series DS III HART Display Without (digital indicator hidden, setting: ma) 1 With visible digital indicator 6 With customer-specific digital indicator (setting 7 as specified, Order code "Y1" or required) Power supply units see "SITRANS I power supply units and isolation amplifiers". Factory-mounting of shut-off valves and valve manifolds see page /16. Included in delivery of the device: Brief instructions (Leporello) CD-ROM with detailed documentation Sealing plug(s) or sealing screw(s) for the process flanges(s) 1) For oxygen applications, add Order code E10. ) Version 7MF4333-1DY... only up to max. span 00 mbar a (.9 psi a). 3) When the manufacture s certificate M (calibration certificate) has to be ordered for transmitters with diaphragm seals, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. 4) Whe the acceptance test certificate 3.1 for transmitters with direct-connected diaphragm seals is ordered, this certificate must also be ordered with the corresponding seals. 5) Not for span " bar a ( psi a)". Position of the top vent valve in the process flange (see dimensional drawing). 6) Not together with Electrical connection Screwed gland Pg 13.5 and Han7D plug. 7) Without cable gland, with blanking plug 8) With enclosed cable gland EEx ia and blanking plug 9) Not together with type of protection "Explosion-proof" and and type of protection "Ex na". 10) Not together with types of protection "Explosion-proof" or "Intrinsic safety and explosion-proof" E) Combinations of the versions marked with E) are subject to the export regulations AL: B30, ECCN: N. F) Subject to export regulations AL: 9I999, ECCN: N. /88 Siemens FI US Edition

89 Transmitters for gage, absolute and differential pressure, flow and level DS III series for absolute pressure (differential construction) Selection and Ordering data Order No. SITRANS P pressure transmitters for absolute pressure (from the differential pressure series) DS III PA series (PROFIBUS PA) F) 7 M F DS III FF series (FOUNDATION Fieldbus) F) 7 M F Measuring cell filling Measuring cell cleaning Silicone oil Standard 1 Inert liquid 1) Grease-free 3 Nominal measuring range 50 mbar a (3.63 psi a) E) D 1300 mbar a (18.9 psi a) E) F 5 bar a (7.5 psi a) E) G 30 bar a (435 psi a) H 100 bar a (1450 psi a) K E Wetted parts materials Seal diaphragm Parts of measuring cell Stainless steel Stainless steel A Hastelloy Stainless steel B Hastelloy Hastelloy C Tantalum Tantalum E Monel Monel E) H Gold Gold L Version as diaphragm seal )3)4) Y Process connection Female thread ¼-18 NPT with flange connection Sealing screw opposite process connection - Mounting thread M10 to DIN Mounting thread 7 / 16-0 UNF to EN Vent on side of process flange 5) - Mounting thread M10 to DIN Mounting thread 7 / 16-0 UNF to EN Non-wetted parts materials Process flange screws Electronics housing Stainless steel Die-cast aluminium Stainless steel Stainless steel precision 3 casting Version Standard version 1 International version, English label inscriptions, documentation in 5 languages on CD Explosion protection Without A With CENELEC, Type of protection: - "Intrinsic safety (EEx ia)" B - "Explosion-proof (EEx d)" 6) D - "Intrinsic safety and explosion-proof enclosure P (EEx ia + EEx d)" 7) - "Ex na/nl (zone )" E - "Intrinsic safety, explosion-proof enclosure and R dust explosion protection (EEx ia + EEx d + Zone 1D/D)" 7) (not for DS III FF) With FM + CSA, Type of protection: - "Intrinsic safety and explosion-proof N C (is + xp)" 6) Electrical connection / cable entry Screwed gland M0x1.5 B Screwed gland ½-14 NPT C M1 Connector (metall) 8) F Siemens AG 007 Selection and Ordering data Order No. SITRANS P pressure transmitters for absolute pressure (from the differential pressure series) DS III PA series (PROFIBUS PA) F) 7 M F DS III FF series (FOUNDATION Fieldbus) F) 7 M F Display Without (digital display hidden) 1 With visible digital indicator 6 With customer-specific digital indicator (setting 7 as specified, Order code "Y1" or required) Factory-mounting of shut-off valves and valve manifolds see page /16. Included in delivery of the device: Brief instructions (Leporello) CD-ROM with detailed documentation Sealing plug(s) or sealing screw(s) for the process flanges(s) 1) For oxygen application, add Order code E10. ) Version 7MF4334-1DY... only up to max. span 00 mbar a (.9 psi a). 3) When the manufacture s certificate M (calibration certificate) has to be ordered for transmitters with diaphragm seals, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. 4) Whe the acceptance test certificate 3.1 for transmitters with direct-connected diaphragm seals is ordered, this certificate must also be ordered with the corresponding seals. 5) Not for nominal measuring range 100 bar a (1450 psi a). Position of the top vent valve in the process flange (see dimensional drawing). 6) Without cable gland, with blanking plug 7) With enclosed cable gland EEx ia and blanking plug 8) Cannot be used together with the following types of protection: "Explosion-proof" and "Intrinsic safety and explosion-proof". E) Combinations of the versions marked with E) are subject to the export regulations AL: B30, ECCN: N. F) Subject to export regulations AL: 9I999, ECCN: N. Siemens FI US Edition /89

90 Transmitters for gage, absolute and differential pressure, flow and level DS III series for absolute pressure (differential construction) Selection and Ordering data Order code Further designs HART PA FF Add "-Z" to Order No. and specify Order code. Pressure transmitter with mounting bracket made of: Steel A01 Stainless steel A0 O-rings for process flanges (instead of FPM (Viton)) PTFE (Teflon) A0 FEP (with silicone core, approved for food) A1 FFPM (Kalrez, compound 4079) A NBR (Buna N) A3 Plug Han 7D (metal, gray) A30 Han 8U (instead of Han 7D) A31 Sealing screws A40 ¼-18 NPT, with valve in material of process flanges Cable sockets for M1 connectors (metal) A50 Rating plate inscription (instead of German) English B11 French B1 Spanish B13 Italian B14 English rating plate B1 Pressure units in inh O or psi Manufacturer's test certificate M C11 (calibration certificate) 1) To DIN 55350, Part 18 and to ISO 840 Acceptance test certificate ) C1 To EN Factory certificate C14 To EN "Functional Safety (SIL)" certificate C0 "PROFIsafe" certificate and protocol C1 Setting of upper limit of output signal to D05.0 ma Manufacturer's declaration acc. to NACE D07 (only together with seal diaphragm made of Hastelloy and stainless steel) Type of protection IP68 D1 (not together with Han 7D/Han 8U plug, cable gland PG 13.5) Digital indicator alongside the input keys D7 (only together with the devices 7MF A.6 or -.A.7-Z, Y1 or Y + Y01) Supplied with oval flange D37 (1 item), PTFE packing and stainless steel screws in thread of process flange Use in or on zone 1D/D E01 (only together with type of protection "Intrinsic safety (EEx ia)") Use on zone 0 E0 (only together with type of protection "Intrinsic safety (EEx ia)") Oxygen cleaning application E10 (max. 160 bar a (30 psi a) with oxygen measurement and inert liquid) Explosion-proof "Intrinsic safety" to E5 INMETRO (Brazil) (only for transmitter 7MF B..) Siemens AG 007 Selection and Ordering data Order code Further designs HART PA FF Add "-Z" to Order No. and specify Order code. Explosion-proof "Intrinsic safety" to NEPSI E55 (China) (only for transmitter 7MF B..) Explosion protection "Explosion-proof" to E56 NEPSI (China) (only for transmitter 7MF D..) Explosion-proof "Zone " to NEPSI (China) E57 (only for transmitter 7MF E..) Interchanging of process connection side H01 Vent on side for gas measurements H0 Process flange Hastelloy K01 Monel K0 Stainless steel with PVDF insert K04 max. PN 10 (MWP 145 psi), max. temperature of medium 90 C (194 F) For ½-14 NPT inner process connection on the side in the middle of the process flange, vent valve not possible Additional data Add "-Z" to Order No. and specify Order code. Measuring range to be set Y01 Specify in plain text (max. 5 digits): Y01:... up to... mbar, bar, kpa, MPa, psi Measuring point number (TAG No.) Y15 Max. 16 characters, specify in plain text: Y15:... Measuring point text Y16 Max. 7 characters, specify in plain text: Y16:... Entry of HART address (TAG) Y17 Max. 8 characters, specify in plain text: Y17:... Setting of pressure indication in pressure Y1 units Specify in plain text (standard setting: ma): Y1: mbar, bar, kpa, MPa, psi,... Note: The following pressure units can be selected: bar, mbar, mm H O *), inh O *), fth O *), mmhg, inhg, psi, Pa, kpa, MPa, g/cm, kg/cm, Torr, ATM oder % *) ref. temperature 0 C Setting of pressure indication in Y + non-pressure units Y01 Specify in plain text: Y:... up to... l/min, m 3 /h, m, USgpm,... (specification of measuring range in pressure units "Y01" is essential, unit with max. 5 characters) Preset bus address Y5 Specify in plain text: Y5:... Only "Y01", "Y1", "Y", "Y5" and "D05" can be factory preset = available 1) ) When the manufacture s certificate M (calibration certificate) has to be ordered for transmitters with diaphragm seals, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. Whe the acceptance test certificate 3.1 for transmitters with direct-connected diaphragm seals is ordered, this certificate must also be ordered with the corresponding seals. /90 Siemens FI US Edition

91 Dimensional drawings Siemens AG 007 Transmitters for gage, absolute and differential pressure, flow and level DS III series for absolute pressure (differential construction) 15 (0.6) 144 (5.67) 51 (.0) 5) approx. 30 (1.) 100 (3.94) 6 50 (1.97) 0 (0.8) Ø 80 (3.15) 1) 5 69 (.7) 77 (3) 4) 1) (4.6) (7.8) approx. 61 (10.3) 134 (5.7) + 1 Space for rotation of housing 8 11 approx. 96 (3.78) 5 (.05) 7 96 (3.8) 7 (.83) 105 (4.1) 1 Process connection: ¼-18 NPT (EN 61518) Blanking plug 3 Electrical connection: - screwed gland Pg 13,5 (adapter) ) 3), - screwed gland M0x1,5 3), - screwed gland ½-14 NPT or ) 3) - Han 7D/ Han 8U plug 4 Terminal side 5 Electronics side, digital display (longer overall length for cover with window) 6 Protective cover over keys 7 Mounting bracket (option) 8 Sealing screw with valve (option) 9 Screw cover - safety bracket (only for type of protection "Explosion-proof enclosure", not shown in the drawing) 10 Lateral venting for liquid measurement (Standard) 11 Lateral venting for gas measurement (suffix H0) ø ( ) 3 68 (.7) 10 (4.7) 1) Allow approx. 0 mm (0.79 inch) thread length to permit unscrewing ) Not with type of protection "explosion-proof enclosure" 3) Not with type of protection "FM + CSA [is + xp]" 4) 9 mm (3.6 inch) for minimum distance to permit rotation with indicator 5) 45 mm (1.8 inch) for Pg 13,5 with adapter SITRANS P pressure transmitters, DS III HART series for absolute pressure, from the differential pressure series, dimensions in mm (inch) Siemens FI US Edition /91

92 Transmitters for gage, absolute and differential pressure, flow and level DS III series for absolute pressure (differential construction) 15 (0.6) 144 (5.67) 51 (.0) Siemens AG 007 approx. 30 (1.) 100 (3.94) 6 Ø 80 (3.15) 50 (1.97) 0 (0.8) 134 (5.7) 1) 5 69 (.7) 77 (3) ) + 1 1) 4 Space for rotation of housing 117 (4.6) (.05) (7.8) 7 ø ( ) 96 (3.8) approx. 61 (10.3) 7 (.83) 105 (4.1) 1 Process connection: ¼-18 NPT (EN 61518) Blanking plug 3 Electrical connection: - screwed gland M0x1,5 4), - screwed gland ½-14 NPT or 3) 4) - PROFIBUS plug M1 4 Terminal side 5 Electronic side, digital display (longer overall length for cover with window) 6 Protective cover over keys 7 Mounting bracket (option) 8 Sealing screw with valve (option) 9 Screw cover safety bracket (only for explosion-proof enclosure, not shown in the drawing) 10 Lateral venting for liquid measurement (Standard) 11 Lateral venting for gas measurement (suffix H0) 68 (.7) 10 (4.7) 1) Allow approx. 0 mm (0.79 inch) thread length in addition ) 9 mm (3.6 inch) for minimum distance to permit rotation with indicator 3) Not with type of protection "explosion-proof enclosure" 4) Not with type of protection "FM + CSA" SITRANS P pressure transmitters, DS III PA and FF series for absolute pressure, from the differential pressure series, dimensions in mm (inch) /9 Siemens FI US Edition

93 Technical specifications Transmitters for gage, absolute and differential pressure, flow and level DS III series for differential pressure and flow SITRANS P, DS III series, for differential pressure and flow Input Measured variable Spans (infinitely adjustable) or nominal measuring range and max. permissible working pressure HART Differential pressure and flow Span Maximum working pressure mbar ( inh O) mbar ( inh O) mbar ( inh O) mbar ( inh O) mbar ( inh O) mbar ( inh O) bar ( psi) mbar ( inh O) mbar ( inh O) mbar ( inh O) mbar ( inh O) bar ( psi) Siemens AG bar (464 psi) 160 bar (30 psi) 40 bar (6091 psi) PROFIBUS PA or FOUNDATION Fieldbus Nominal measuring range 0 mbar g (8 inh O) 60 mbar (4 inh O) 50 mbar (100 inh O) 600 mbar (40 inh O) 1600 mbar (64 inh O) 5 bar (000 inh O) 30 bar (435 psi) 50 mbar (100 inh O) 600 mbar (40 inh O) 1600 mbar (64 inh O) 5 bar (000 inh O) 30 bar (435 psi) Maximum working pressure 3 bar (464 psi) 160 bar (30 psi) 40 bar (6091 psi) Lower measuring limit Measuring cell with silicone oil filling -100% of max. span (-33% with 30 bar (435 psi) measuring cell or 30 mbar a (0.44 psi)) Upper measuring limit 100% of max. span (for oxygen version and inert filling liquid; max. 160 bar g (30 psi g)) Output Output signal ma Digital PROFIBUS PA or FOUNDATION Fieldbus signal Lower limit (infinitely adjustable) 3.55 ma, factory preset to 3.84 ma - Upper limit (infinitely adjustable) 3 ma, factory preset to 0.5 ma or optionally set - to.0 ma Load Without HART communication R B (U H V)/0.03 A in Ω, - U H : Power supply in V With HART communication R B = Ω (SIMATIC PDM) or - R B = Ω (HART Communicator) Physical bus - IEC With polarity reversal protection - Yes Accuracy To EN Reference conditions Increasing characteristic, start-of-scale value 0 bar, stainless steel seal diaphragm, silicone oil filling, room temperature 5 C (77 F)) r: Span ratio (r = max. span / set span) Error in measurement and fixed-point setting (including hysteresis and repeatability) Linear characteristic 0,075% -r 10 (0.009 r )% - 10 < r 30 ( r )% - 30 < r 100 (0.005 r )% Square-root characteristic (flow > 50%) 0,1% -r 10 0,1% - 10 < r 30 0,% Siemens FI US Edition /93

94 Siemens AG 007 Transmitters for gage, absolute and differential pressure, flow and level DS III series for differential pressure and flow SITRANS P, DS III series, for differential pressure and flow HART PROFIBUS PA or FOUNDATION Fieldbus Square-root characteristic (flow %) 0, -r 10 0,% < r 30 0,4% - Long-term drift (temperature change ± 30 C (± 54 F)) (0.5 r)% every 5 years static pressure max. 70 bar g (1015 psi g) (0.5% every 5 years static pressure max. 70 bar g (1015 psi g) 0 mbar (0.9 psi)-measuring cell (0. r) per year 0. per year Influence of ambient temperature at C ( F) (0.08 r + 0.1)% 0,3% at C and C (0.1 r )%/10 K 0.5%/10 K ( F and F) (Twice the value with 0-mbar (0.9 psi) measuring cell) Influence of static pressure on the zero point (0.15 r)% per 100 bar (1450 psi) 0.15% je 100 bar (1450 psi) - 0 mbar (0.9 psi)-measuring cell (0.15 r)% per 3 bar (464 psi) 0.15% je 3 bar (464 psi) on the span 0.% je 100 bar (1450 psi) mbar (0.9 psi)-measuring cell 0.% je 3 bar (464 psi) - Measured Value Resolution of nominal measuring range Rated operating conditions Degree of protection (to EN 6059) IP65 Process temperature Measuring cell with silicone oil filling C ( F) Measuring cell with inert filling liquid C ( F) In conjunction with dust explosion protection C ( F) Ambient conditions Ambient temperature - Digital indicators C ( F) Storage temperature C ( F) Climatic class - Condensation Permissible Electromagnetic compatibility - Emitted interference and interference To EN 6136 and NAMUR NE 1 immunity Design Weight (without options) 4.5 kg ( 9.9 lb) Housing material Low copper die-cast aluminium, GD-AlSi1 or stainless steel precision casting, mat. No Wetted parts materials Seal diaphragm Stainless steel, mat. No /316L or Hastelloy C76, mat. No..4819, Monel, mat. No..4360, tantalum or gold Measuring cell filling Silicone oil or inert filling liquid (max. 160 bar (30 psi g) with oxygen measurement) Process connection Female thread ¼-18 NPT and flange connection with mounting thread M10 to DIN 1913 or / 16-0 UNF to EN Power supply U H Supplied through bus Terminal voltage on transmitter V DC V DC in intrinsically-safe mode Separate 4 V power supply necessary - No Bus voltage Not Ex V With intrinsically-safe operation V Current consumption Basic current (max.) ma Startup current basic current - Yes Max. current in event of fault ma Fault disconnection electronics (FDE) avail. - Yes /94 Siemens FI US Edition

95 Siemens AG 007 Transmitters for gage, absolute and differential pressure, flow and level DS III series for differential pressure and flow SITRANS P, DS III series, for differential pressure and flow HART Certificate and approvals Classification according to pressure equipment directive (DRGL 97/3/EC) PN 3/160 (MWP 464/30 psi) PN 40 (MWP 609 psi) For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of Article 3, paragraph 3 (sound engineering practice) For gases of fluid group 1 and liquids of fluid group 1; complies with basic safety requirements of Article 3, paragraph 1 (appendix 1); assigned to category III, conformity evaluation module H by the TÜV Nord. Explosion protection Intrinsic safety "i" PTB 99 ATEX 1 - Identification Ex II 1/ G EEx ia/ib IIB/IIC T6 - Permissible ambient temperature C ( F) temperature class T4; C ( F) temperature class T5; C ( F) temperature class T6 - Connection To certified intrinsically-safe circuits with maximum values: U i = 30 V, I i = 100 ma, P i = 750 mw; R i = 300 Ω FISCO supply unit: U o = 17.5 V, I o = 380 ma, P o = 5.3 W Linear barrier: U o = 4 V, I o = 50 ma, P o = 1. W - Effective internal inductance/capacitance L i = 0.4 mh, C i = 6 nf L i = 7 µh, C i = 1.1 nf Explosion-proof "d" PTB 99 ATEX Identification Ex II 1/ G EEx d IIC T4/T6 - Permissible ambient temperature C ( F) temperature class T4; C ( F) temperature class T6 - Connection To circuits with values: U H = V DC To circuits with values: U H = V DC Dust explosion protection for zone 0 PTB 01 ATEX Identification Ex II 1 D IP65 T 10 C Ex II 1/ D IP65 T 10 C - Permissible ambient temperature C ( F) - Max.surface temperature 10 C (48 F) - Connection To certified intrinsically-safe circuits with maximum values: U i = 30 V, I i = 100 ma, P i = 750 mw, R i = 300 Ω FISCO supply unit: U o = 17.5 V, I o = 380 ma, P o = 5.3 W Linear barrier: U o = 4 V, I o = 50 ma, P o = 1. W - Effective internal inductance/capacitance L i = 0.4 mh, C i = 6 nf L i = 7 µh, C i = 1.1 nf Dust explosion protection for zone 1/ PTB 01 ATEX Identification Ex II D IP65 T 10 C - Connection To circuits with values: U H = V DC; P max = 1. W PROFIBUS PA or FOUNDATION Fieldbus To circuits with values: U H = V DC; P max = 1. W Type of protection "n" (zone ) TÜV 01 ATEX 1696 X Planned - Identification Ex II 3 G EEx na L IIC T4/T5/T6 - Explosion protection to FM Certificate of Compliance Identification (XP/DIP) or (IS); (NI) CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; CL I, ZN 0/1 AEx ia IIC T4...T6; CL I, DIV, GP ABCD T4...T6; CL II, DIV, GP FG; CL III Explosion protection to CSA Certificate of Compliance Identification (XP/DIP) or (IS) CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; Ex ia IIC T4...T6; CL I, DIV, GP ABCD T4...T6; CL II, DIV, GP FG; CL III Siemens FI US Edition /95

96 Transmitters for gage, absolute and differential pressure, flow and level DS III series for differential pressure and flow HART communication HART communication Ω Protocol HART Version 5.x Software for computer SIMATIC PDM PROFIBUS PA communication Simultaneous communication with master class (max.) The address can be set using Cyclic data usage Output byte Input byte Internal preprocessing Device profile Function blocks Analog input - Adaptation to customer-specific process variables - Electrical damping T 63, adjustable 4 Configuration tool or local operation (standard setting address 16) 5 (one measuring value) or 10 (two measuring values) 0, 1, or (register operating mode and reset function for metering) PROFIBUS PA Profile for Process Control Devices Version 3.0, Class B Yes, linearly rising or falling characteristic s - Simulation function Input /Output - Failure mode Can be parameterized (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively Register (totalizer) Can be reset, preset, optional direction of counting, simulation function of register output - Failure mode Can be parameterized (summation with last good value, continuous summation, summation with incorrect value) - Limit monitoring One upper and lower warning limit and one alarm limit respectively Physical block 1 Transducer blocks Pressure transducer block - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Characterizer Max. 30 points - Square-rooted characteristic Yes for flow measurement - Gradual volume suppression Parameterizable and implementation point of square-root extraction - Simulation function for measured pressure value and sensor temperature Constant value or over parameterizable ramp function Siemens AG 007 Communication FOUNDATION Fieldbus Function blocks 3 function blocks analog input, 1 function block PID Analog input - Adaptation to customer-specific process variables - Electrical damping T 63, adjustable Yes, linearly rising or falling characteristic s - Simulation function Output/input (can be locked within the device with a bridge) - Failure mode Can be parameterized (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively - Square-rooted characteristic Yes for flow measurement PID Standard FF function block Physical block 1 Resource block Transducer blocks 1 transducer block Pressure with calibration, 1 transducer block LCD Pressure transducer block - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Simulation function: Measured pressure value, sensor temperature and electronics temperature Constant value or over parameterizable ramp function /96 Siemens FI US Edition

97 Selection and Ordering data SITRANS P pressure transmitters for differential pressure and flow, Series DS III HART PN 3/160 (MWP 464/30 psi) Measuring cell filling Measuring cell cleaning Transmitters for gage, absolute and differential pressure, flow and level DS III series for differential pressure and flow Order No. 7 M F Y Silicone oil Standard } 1 Inert liquid 1) Grease-free 3 Span PN 3 (MWP 464 psi) mbar ) ( inh O) } B PN 160 (MWP 30 psi) mbar ( inh O) } C mbar ( inh O) } D mbar ( inh O) } E mbar ( inh O) } F mbar ( inh O) } G bar ( psi) } H Wetted parts materials (stainless steel process flanges) Seal diaphragm Parts of measuring cell Stainless steel Stainless steel } A Hastelloy Stainless steel F) B Hastelloy Hastelloy F) C Tantalum 3) Tantalum E Monel 3) Monel F) H Gold 3) Gold L Version for diaphragm seal4) 5) Process connection Female thread ¼-18 NPT with flange connection Sealing screw opposite process connection - Mounting thread M10 to DIN 1913 } 0 - Mounting thread 7 / 16-0 UNF to EN Vent on side of process flange ) - Mounting thread M10 to DIN Mounting thread 7 / 16-0 UNF to EN Non-wetted parts materials Process flange screws Electronics housing Stainless steel Die-cast aluminium } Stainless steel Stainless steel precision 3 casting 6) Version Standard version 1 International version, English label inscriptions, } documentation in 5 languages on CD Explosion protection Without A With ATEX, Type of protection: - "Intrinsic safety (EEx ia)" B - "Explosion-proof (EEx d)" 7) F) D - "Intrinsic safety and explosion-proof F) P enclosure (EEx ia + EEx d)" 8) - "Ex na/nl (zone )" E - "Intrinsic safety, explosion-proof enclosure and dust explosion protection (EEx ia + EEx d + Zone 1D/D)" 8) With FM + CSA, Type of protection: - "Intrinsic safety and explosion-proof F) N C (is + xp)" 7) Electrical connection / cable entry Screwed gland Pg ) A Screwed gland M0x1.5 } B Screwed gland ½-14 NPT C Han 7D plug (plastic housing) incl. mating F) D connector 10) M1 connectors (metal) 10) F } F) Siemens AG 007 R Selection and Ordering data Order No. SITRANS P pressure transmitters for differential pressure and flow, Series DS III HART 7 M F PN 3/160 (MWP 464/30 psi) Display without (digital indicator hidden, setting: ma) } 1 With visible digital indication 6 With customer-specific digital indication (setting 7 as specified, Order code "Y1" or required) } Available ex stock Power supply units see "SITRANS I power supply units and isolation amplifiers". Factory-mounting of shut-off valves and valve manifolds see page /16. Included in delivery of the device: Brief instructions (Leporello) CD-ROM with detailed documentation Sealing plug(s) or sealing screw(s) for the process flanges(s) 1) For oxygen cleaning application, add Order code E10. ) Not suitable for connection of remote seal. Position of the top vent valve in the process flanges (see dimensional drawing). 3) Only together with max. spans 50, 1600, 5000 and mbar (100.4, 40.9, 008 inh O and 435 psi) 4) When the manufacture s certificate M (calibration certificate) has to be ordered for transmitters with diaphragm seals, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. 5) Whe the acceptance test certificate 3.1 for transmitters with direct-connected diaphragm seals is ordered, this certificate must also be ordered with the corresponding seals. 6) Not together with Electrical connection Screwed gland Pg 13.5 and Han7D plug. 7) Without cable gland, with blanking plug 8) With enclosed cable gland EEx ia and blanking plug 9) Not together with type of protection "Explosion-proof" and and type of protection "Ex na". 10) Cannot be used together with the following types of protection: "Explosion-proof" and "Intrinsic safety and explosion-proof" F) Subject to export regulations AL: 9I999, ECCN: N. Siemens FI US Edition /97

98 Transmitters for gage, absolute and differential pressure, flow and level DS III series for differential pressure and flow Selection and Ordering data Order No. SITRANS P pressure transmitters for differential pressure and flow PN 3/160 (MWP 464/30 psi) DS III PA series (PROFIBUS PA) 7 M F DS III FF series (FOUNDATION Fieldbus) 7 M F Y Measuring cell filling Measuring cell cleaning Silicone oil Standard 1 Inert liquid 1) Grease-free 3 Nominal measuring range PN 3 (MWP 464 psi) 0 mbar ) (8.03 inh O) B PN 160 (MWP 30 psi) 60 mbar (4.09 inh O) C 50 mbar (100.4 inh O) D 600 mbar (40.9 inh O) E 1600 mbar (64.4 inh O) F 5 bar (008 inh O) G 30 bar (435 psi) H Wetted parts materials (stainless steel process flanges) Seal diaphragm Parts of measuring cell Stainless steel Stainless steel A Hastelloy Stainless steel F) B Hastelloy Hastelloy F) C Tantalum 3) Tantalum E Monel ) Monel F) H Gold ) Gold L 4) 5) Version as diaphragm seal Process connection Female thread ¼-18 NPT with flange connection Sealing screw opposite process connection - Mounting thread M10 to DIN Mounting thread 7 / 16-0 UNF to EN Venting on side of process flanges ) - Mounting thread M10 to DIN Mounting thread 7 / 16-0 UNF to EN Non-wetted parts materials Process flange screws Electronics housing Stainless steel Die-cast aluminium Stainless steel Stainless steel precision 3 casting Version Standard version 1 International version, English label inscriptions, documentation in 5 languages on CD Explosion protection Without A With CENELEC, Type of protection: - "Intrinsic safety (EEx ia)" B - "Explosion-proof (EEx d)" 6) F) D - "Intrinsic safety and explosion-proof F) P enclosure (EEx ia + EEx d)" 7) - "n (Zone )" (planned) E - "Intrinsic safety, explosion-proof enclosure F) R and dust explosion protection (EEx ia + EEx d + Zone 1D/D)" 7) (not for DS III FF) With FM + CSA, Type of protection: - "Intrinsic safety and explosion-proof (is + xp)" 6) F) N C Siemens AG 007 Selection and Ordering data Order No. SITRANS P pressure transmitters for differential pressure and flow PN 3/160 (MWP 464/30 psi) DS III PA series (PROFIBUS PA) 7 M F DS III FF series (FOUNDATION Fieldbus) 7 M F Electrical connection / cable entry Screwed gland M0x1.5 B Screwed gland ½-14 NPT C M1 connectors (metal) 8) F Display Without (digital display hidden) 1 With visible digital indication 6 With customer-specific digital indication (setting 7 as specified, Order code "Y1" or required) Included in delivery of the device: Brief instructions (Leporello) CD-ROM with detailed documentation Sealing plug(s) or sealing screw(s) for the process flanges(s) 1) For oxygen cleaning application, add Order code E10. ) Not suitable for connection of remote seal. Position of the top vent valve in the process flanges (see dimensional drawing). 3) Only together with max. spans 50, 1600, 5000 and mbar (100.4, 40.9, 008 inh O and 435 psi). 4) When the manufacture s certificate M (calibration certificate) has to be ordered for transmitters with diaphragm seals, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. 5) Whe the acceptance test certificate 3.1 for transmitters with direct-connected diaphragm seals is ordered, this certificate must also be ordered with the corresponding seals. 6) Without cable gland, with blanking plug. 7) With enclosed cable gland EEx ia and blanking plug. 8) Cannot be used together with the following types of protection: "Explosion-proof" and "Intrinsic safety and explosion-proof". F) Subject to export regulations AL: 9I999, ECCN: N. /98 Siemens FI US Edition

99 Selection and Ordering data Further designs Add "-Z" to Order No. and specify Order code. Transmitters for gage, absolute and differential pressure, flow and level DS III series for differential pressure and flow Order code HART PA FF Pressure transmitter with mounting bracket made of: Steel A01 Stainless steel A0 O-rings for process flanges (instead of FPM (Viton)) PTFE (Teflon) A0 FEP (with silicone core, approved for food) A1 FFPM (Kalrez, compound 4079) A NBR (Buna N) A3 Plug Han 7D (metal, gray) A30 Han 8U (instead of Han 7D) A31 Sealing screws A40 ¼-18 NPT, with valve in mat. of process flanges Cable sockets for M1 connectors (metal) A50 Rating plate inscription (instead of German) English B11 French B1 Spanish B13 Italian B14 English rating plate (calibration certificate) B1 Pressure units in inh O or psi Manufacturer's test certificate M 1) C11 To DIN 55350, Part 18 and to ISO 840 Acceptance test certificate ) C1 To EN Factory certificate C14 To EN "Functional Safety (SIL)" certificate C0 "PROFIsafe" certificate and protocol C1 Setting of upper limit of output signal to D05.0 ma Manufacturer's declaration acc. to NACE D07 (only together with seal diaphragm made of Hastelloy and stainless steel) Type of protection IP68 D1 (not together with 7D/ Han 8U plug, cable gland Pg 13.5) Digital indicator alongside the input keys D7 (only together with the devices 7MF A.6 or -.A.7-Z, Y1 or Y + Y01) Process flange screws made of Monel D34 (max. nominal pressure PN0) Supplied with oval flange set D37 F) ( items), PTFE packings and stainles steel screws in thread of process flanges Use in or on zone 1D/D E01 (only together with type of protection "Intrinsic safety (EEx ia)") Use on zone 0 E0 (only together with type of protection "Intrinsic safety (EEx ia)") TÜV approval to AD/TRD E06 (only together with type of protection "Intrinsic safety (EEx ia)") Overfilling safety device for flammable and non-flammable liquids (max. PN 3 (MVWP 464 psi), basic device with type of protection "Intrinsic safety (EEx ia)", to WHG and VbF, not together with measuring cell filling "inert liquid") E08 Siemens AG 007 Selection and Ordering data Order code Further designs HART PA FF Add "-Z" to Order No. and specify Order code. Oxygen cleaning application E10 (max. 160 bar (30 psi) with oxygen measurement and inert liquid) Explosion-proof "Intrinsic safety" to E5 INMETRO (Brazil) (only for transmitter 7MF B..) Explosion-proof "Intrinsic safety" to NEPSI E55 (China) (only for transmitter 7MF B..) Explosion protection "Explosion-proof" to E56 NEPSI (China) (only for transmitter 7MF D..) Explosion-proof "Zone " to NEPSI (China) E57 (only for transmitter 7MF E..) Interchanging of process connection side H01 Vent on side for gas measurements H0 Stainless steel process flanges for vertical H03 differential pressure lines (not together with K01, K0 and K04) 3) Process flange Hastelloy K01 F) Monel K0 F) Stainless steel with PVDF insert K04 max. PN 10 (MWP 145 psi), max. temperature of medium 90 C (194 F) For ½-14 NPT inner process connection on the side in the middle of the process flange, vent valve not possible = available 1) ) 3) When the manufacture s certificate M (calibration certificate) has to be ordered for transmitters with diaphragm seals, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. Whe the acceptance test certificate 3.1 for transmitters with direct-connected diaphragm seals is ordered, this certificate must also be ordered with the corresponding seals. Not suitable for connection of remote seal F) Subject to export regulations AL: 9I999, ECCN: N. Siemens FI US Edition /99

100 Transmitters for gage, absolute and differential pressure, flow and level DS III series for differential pressure and flow Selection and Ordering data Order code Additional data HART PA FF Add "-Z" to Order No. and specify Order code. Measuring range to be set Specify in plain text: With linear characteristic (max. 5 digits): Y01 Y01:... up to... mbar, bar, kpa, MPa, psi With square-rooted characteristic (max. 5 Y0 digits): Y01:... up to... mbar, bar, kpa, MPa, psi Measuring point number (TAG No.) Y15 Max. 16 char., specify in plain text: Y15:... Measuring point text Y16 Max. 7 char., specify in plain text: Y16:... Entry of HART address (TAG) Y17 Max. 8 char., specify in plain text: Y17:... Setting of pressure indicator in pressure Y1 units Specify in plain text (standard setting: ma): Y1: mbar, bar, kpa, MPa, psi,... Note: The following pressure units can be selected: bar, mbar, mm H O *), inh O *), fth O *), mmhg, inhg, psi, Pa, kpa, MPa, g/cm, kg/cm, Torr, ATM oder % *) ref. temperature 0 C Setting of pressure indicator in non-pressure units Specify in plain text: Y:... up to... l/min, m 3 /h, m, USgpm,... Y 1) + Y01 or Y0 (specification of measuring range in pressure units "Y01" or "Y0" is essential, unit with max. 5 characters) Preset bus address Y5 Specify in plain text: Y5:... Only "Y01", "Y1", "Y", "Y5" and "D05" can be factory preset = available Siemens AG 007 1) Not together with over-filling safety device for flammable and non-flammable liquids (Order code "E08") /100 Siemens FI US Edition

101 Selection and Ordering data SITRANS P pressure transmitters for differential pressure and flow, Series DS III HART PN 40 (MWP 609 psi) Measuring cell filling Measuring cell cleaning Transmitters for gage, absolute and differential pressure, flow and level DS III series for differential pressure and flow Silicone oil Standard 1 Order No. 7 M F Span mbar ( inh O) D mbar ( inh O) E mbar ( inh O) F mbar ( inh O) G bar ( psi) H Wetted parts materials (stainless steel process flanges) Seal diaphragm Parts of measuring cell Stainless steel Stainless steel A Hastelloy Stainless steel F) B Gold 1) Gold L Process connection Female thread ¼-18 NPT with flange connection Sealing screw opposite process connection - Mounting thread M1 to DIN Mounting thread 7 / 16-0 UNF to EN Venting on side of process flanges. Position of the top vent valve in the process flanges (see dimensional drawing). - Mounting thread M1 to DIN Mounting thread 7 / 16-0 UNF to EN Non-wetted parts materials Process flange screws Electronics housing Stainless steel Die-cast aluminium Stainless steel Stainless steel precision 3 casting ) Version Standard version 1 International version, English label inscriptions, documentation in 5 languages on CD Explosion protection Without A With ATEX, Type of protection: - "Intrinsic safety (EEx ia)" B 3) - "Explosion-proof (EEx d)" F) D - "Intrinsic safety and explosion-proof F) P enclosure (EEx ia + EEx d)" 4) -"Ex na/nl (zone )" E - "Intrinsic safety, explosion-proof enclosure F) R and dust explosion protection (EEx ia + EEx d + Zone 1D/D)" 4) With FM + CSA, Type of protection: - "Intrinsic safety and explosion-proof F) N C (is + xp)" 3), max PN 360 Electrical connection / cable entry Screwed gland Pg ) A Screwed gland M0x1.5 B Screwed gland ½-14 NPT C Han 7D plug (plastic housing) incl. mating D connector 5) M1 connectors (metal) 6) F Siemens AG 007 Selection and Ordering data Order No. SITRANS P pressure transmitters for differential pressure and flow, Series DS III HART 7 M F PN 40 (MWP 609 psi) Display without (digital indicator hidden, setting: ma) 1 With visible digital indication 6 With customer-specific digital indication (setting 7 as specified, Order code "Y1" or required) Power supply units see "SITRANS I power supply units and isolation amplifiers". Scope of delivery: Pressure transmitter as ordered (Instruction Manual is extra ordering item) 1) Not together with max. span 600 mbar (40.9 inh O) ) Not together with Electrical connection Screwed gland Pg 13.5 and Han7D plug. 3) Without cable gland, with blanking plug 4) With enclosed cable gland EEx ia and blanking plug 5) Not together with type of protection "Explosion-proof" and and type of protection "Ex na". 6) Cannot be used together with the following types of protection: "Explosion-proof" and "Intrinsic safety and explosion-proof". F) Subject to export regulations AL: 9I999, ECCN: N. Siemens FI US Edition /101

102 Transmitters for gage, absolute and differential pressure, flow and level DS III series for differential pressure and flow Selection and Ordering data Order No. SITRANS P pressure transmitters for differential pressure and flow, Series DS III HART PN 40 (MWP 609 psi) DS III PA (PROFIBUS PA) series 7 M F DS III FF series (FOUNDATION Fieldbus) 7 M F Nominal measuring range 50 mbar (100.4 inh O) D 600 mbar (40.9 inh O) E 1600 mbar (64.4 inh O) F 5 bar (008 inh O) G 30 bar (435 psi) H Wetted parts materials (stainless steel process flanges) Seal diaphragm Parts of measuring cell Stainless steel Stainless steel A Hastelloy Stainless steel F) B Gold 1) Gold L Process connection Female thread ¼-18 NPT with flange connection Sealing screw opposite process connection - Mounting thread M1 to DIN Mounting thread 7 / 16-0 UNF to EN Venting on side of process flanges. Position of the top vent valve in the process flanges (see dimensional drawing). - Mounting thread M1 to DIN Mounting thread 7 / 16-0 UNF to EN Non-wetted parts materials Process flange screws Electronics housing Stainless steel Die-cast aluminium Stainless steel Stainless steel precision 3 casting Version Standard version 1 International version, English label inscriptions, documentation in 5 languages on CD Explosion protection Without A With CENELEC, Type of protection: - "Intrinsic safety (EEx ia)" B - "Explosion-proof (EEx d)" ) F) D - "Intrinsic safety and explosion-proof F) P enclosure (EEx ia + EEx d)" 3) - "Ex na/nl (zone )" E - "Intrinsic safety, explosion-proof enclosure F) R and dust explosion protection (EEx ia + EEx d + Zone 1D/D)" 3) (not for DS III FF) With FM + CSA, Type of protection: - "Intrinsic safety and explosion-proof F) N C (is + xp)" ), max PN 360 Electrical connection / cable entry Screwed gland M0x1.5 B Screwed gland ½-14 NPT C Plug M1 incl. mating connector 4) F Display Without (digital display hidden) 1 With visible digital indicator 6 With customer-specific digital indicator (setting 7 as specified, Order code "Y1" or required) Factory-mounting of shut-off valves and valve manifolds see page /16. Included in delivery of the device: Brief instructions (Leporello) CD-ROM with detailed documentation Sealing plug(s) or sealing screw(s) for the process flanges(s) Siemens AG 007 1) Not together with max. span 600 mbar (40.9 inh O) ) Without cable gland, with blanking plug. 3) With enclosed cable gland EEx ia and blanking plug. 4) Not together with types of protection "Explosion-proof" and "Intrinsic safety and explosion-proof" F) Subject to export regulations AL: 9I999, ECCN: N. /10 Siemens FI US Edition

103 Selection and Ordering data Transmitters for gage, absolute and differential pressure, flow and level DS III series for differential pressure and flow Order code Further designs HART PA FF Add "-Z" to Order No. and specify Order code. Pressure transmitter with mounting bracket made of: Steel A01 Stainless steel A0 O-rings for process flanges (instead of FPM (Viton)) PTFE (Teflon) A0 FEP (with silicone core, approved for food) A1 FFPM (Kalrez, compound 4079) A NBR (Buna N) A3 Plug Han 7D (metal, gray) A30 Han 8U (instead of Han 7D) A31 Sealing screws A40 ¼-18 NPT, with valve in material of process flanges Cable sockets for M1 connectors (metal) A50 Rating plate inscription (instead of German) English B11 French B1 Spanish B13 Italian B14 English rating plate B1 Pressure units in inh O or psi Manufacturer's test certificate M C11 (calibration certificate) To DIN 55350, Part 18 and to ISO 840 Acceptance test certificate C1 To EN Factory certificate C14 To EN "Functional Safety (SIL)" certificate C0 "PROFIsafe" certificate and protocol C1 Setting of upper limit of output signal to D05.0 ma Manufacturer's declaration acc. to NACE D07 (only together with seal diaphragm made of Hastelloy and stainless steel) Type of protection IP68 D1 (not together with Han 7D / Han 8U plug, Pg 13.5 screwed gland) Digital indicator alongside the input keys D7 (only together with the devices 7MF A.6 or -.A.7-Z, Y1 or Y + Y01) Use in or on zone 1D/D E01 (only together with type of protection "Intrinsic safety (EEx ia)") Use on zone 0 E0 (only together with type of protection "Intrinsic safety (EEx ia)") Explosion-proof "Intrinsic safety" to E5 INMETRO (Brazil) (only for transmitter 7MF B..) Explosion-proof "Intrinsic safety" to E55 NEPSI (China) (only for transmitter 7MF B..) Siemens AG 007 Selection and Ordering data Order code Further designs HART PA FF Add "-Z" to Order No. and specify Order code. Explosion protection "Explosion-proof" to E56 NEPSI (China) (only for transmitter 7MF D..) Explosion-proof "Zone " to NEPSI (China) E57 (only for transmitter 7MF E..) Interchanging of process connection side H01 Stainless steel process flanges for H03 vertical differential pressure lines Additional data Add "-Z" to Order No. and specify Order code. Measuring range to be set Specify in plain text: With linear characteristic (max. 5 digits): Y01 Y01:... up to... mbar, bar, kpa, MPa, psi With square-rooted characteristic (max. 5 Y0 digits): Y01:... up to... mbar, bar, kpa, MPa, psi Measuring point number (TAG No.) Y15 Max. 16 characters, specify in plain text: Y15:... Measuring point text Y16 Max. 7 characters, specify in plain text: Y16:... Entry of HART address (TAG) Y17 Max. 8 characters, specify in plain text: Y17:... Setting of pressure indication in pressure Y1 units Specify in plain text (standard setting: ma): Y1: mbar, bar, kpa, MPa, psi,... Note: The following pressure units can be selected: bar, mbar, mm H O *), inh O *), fth O *), mmhg, inhg, psi, Pa, kpa, MPa, g/cm, kg/cm, Torr, ATM or % *) ref. temperature 0 C Setting of pressure indication in Y + non-pressure units Specify in plain text: Y:... up to... l/min, m 3 /h, m, USgpm,... (specification of measuring range in pressure units "Y01" or "Y0" is essential, unit with max. 5 characters) Preset bus address Y01 or Y0 Y5 Specify in plain text: Y5:... Only "Y01", "Y1", "Y", "Y5" and "D05" can be factory preset = available Siemens FI US Edition /103

104 Transmitters for gage, absolute and differential pressure, flow and level DS III series for differential pressure and flow Dimensional drawings Siemens AG (0.6) 144 (5.67) 51 (.0) 5) approx. 30 (1.) 100 (3.94) 6 50 (1.97) 0 (0.8) Ø 80 (3.15) 1) 5 69 (.7) 77 (3) 4) 1) (4.6) (7.8) approx. 61 (10.3) 134 (5.7) + 1 Space for rotation of housing 8 11 approx. 96 (3.78) 5 (.05) 7 96 (3.8) 7 (.83) 105 (4.1) 1 Process connection: ¼-18 NPT (EN 61518) Blanking plug 3 Electrical connection: - screwed gland Pg 13,5 (adapter) ) 3), - screwed gland M0x1,5 3), - screwed gland ½-14 NPT or ) 3) - Han 7D/ Han 8U plug 4 Terminal side 5 Electronics side, digital display (longer overall length for cover with window) 6 Protective cover over keys 7 Mounting bracket (option) 8 Sealing screw with valve (option) 9 Screw cover - safety bracket (only for type of protection "Explosion-proof enclosure", not shown in the drawing) 10 Lateral venting for liquid measurement (Standard) 11 Lateral venting for gas measurement (suffix H0) ø ( ) 3 68 (.7) 10 (4.7) 1) Allow approx. 0 mm (0.79 inch) thread length to permit unscrewing ) Not with type of protection "explosion-proof enclosure" 3) Not with type of protection "FM + CSA [is + xp]" 4) 9 mm (3.6 inch) for minimum distance to permit rotation with indicator 5) 45 mm (1.8 inch) for Pg 13,5 with adapter SITRANS P pressure transmitters, DS III HART series for differential pressure and flow, dimensions in mm (inch) /104 Siemens FI US Edition

105 15 (0.6) Transmitters for gage, absolute and differential pressure, flow and level DS III series for differential pressure and flow 144 (5.67) 51 (.0) Siemens AG 007 approx. 30 (1.) 100 (3.94) 6 Ø 80 (3.15) 50 (1.97) 0 (0.8) 134 (5.7) 1) 5 69 (.7) 77 (3) ) + 1 1) 4 Space for rotation of housing 117 (4.6) (.05) (7.8) 7 ø ( ) 96 (3.8) approx. 61 (10.3) 7 (.83) 105 (4.1) 1 Process connection: ¼-18 NPT (EN 61518) Blanking plug 3 Electrical connection: - screwed gland M0x1,5 4), - screwed gland ½-14 NPT or 3) 4) - PROFIBUS plug M1 4 Terminal side 5 Electronic side, digital display (longer overall length for cover with window) 6 Protective cover over keys 7 Mounting bracket (option) 8 Sealing screw with valve (option) 9 Screw cover safety bracket (only for explosion-proof enclosure, not shown in the drawing) 10 Lateral venting for liquid measurement (Standard) 11 Lateral venting for gas measurement (suffix H0) 68 (.7) 10 (4.7) 1) Allow approx. 0 mm (0.79 inch) thread length in addition ) 9 mm (3.6 inch) for minimum distance to permit rotation with indicator 3) Not with type of protection "explosion-proof enclosure" 4) Not with type of protection "FM + CSA" SITRANS P pressure transmitters, DS III PA and FF series for differential pressure and flow, dimensions in mm (inch) Siemens FI US Edition /105

106 Transmitters for gage, absolute and differential pressure, flow and level DS III series for differential pressure and flow 15 (0.6) 74 (.9) 144 (5.67) 51 (.0) 0 (0.8) Siemens AG 007 approx. 30 (1.18) 8) approx. 96 (3.78) 100 (3.94) 6 50 (1.97) Ø 80 (3.15) 4 1) ) 77 (3) 4) Space for rotation of housing approx. 85 (3.35) 6) approx. 17 (8.54) 7) 1 67 (.64) 5) approx. 84,6 (3.33) 1 Process connection: ¼-18 NPT (EN 61518) Blanking plug 3 Electrical connection: - screwed gland Pg 13,5 (adapter) ) 3), - screwed gland M0x1,5 3), - screwed gland ½-14 NPT or ) 3) - Han 7D/ Han 8U plug 4 Terminal side 5 Electronics side, digital display (longer overall length for cover with window) 6 Protective cover over keys 7 Mounting bracket (option) 8 Sealing screw with valve (option) 9 Screw cover - safety bracket (only for type of protection "Explosion-proof enclosure", not shown in the drawing) 1) Allow approx. 0 mm (0.79 inch) thread length to permit unscrewing ) Not with type of protection "explosion-proof enclosure" 3) Not with type of protection "FM + CSA [is + xp]" 4) 9 mm (3.6 inch) for minimum distance to permit rotation with indicator 5) 74 mm (.9 inch) for PN ³ 40 (MWP ³ 609 psi) 6) 91 mm (3.6 inch) for PN ³ 40 (MWP ³ 609 psi) 7) 19 mm (8.6 inch) for PN ³ 40 (MWP ³ 609 psi) 8) 45 mm (1.8 inch) for Pg 13,5 with adapter SITRANS P pressure transmitters, DS III HART series for differential pressure and flow, with process covers for vertical differential pressure lines, dimensions in mm (inch) /106 Siemens FI US Edition

107 15 (0.6) Transmitters for gage, absolute and differential pressure, flow and level DS III series for differential pressure and flow 144 (5.67) approx 30 (1.18) 6) 100 (3.94) (.9) (.0) 0 (0.8) Siemens AG ) 3 5 1) Space for rotation of housing approx. 50 (1.97) diam. 80 (3.15) 77 (3) ) 85 (3.35) 4) approx. 17 (8.54) 5) 1 67 (.64) 3) approx. 84,6 (3.33) 1 Process connection ¼-18 NPT (EN ) Blanking plug 3 Electrical connection: screwed gland M0x1.5, screwed gland ½-14 NPT or PROFIBUS plug M1 4 Terminal side 5 Electronics side, digital display (longer overall length for cover with window) 6 Protective cover over keys 7 Mounting bracket (option) 8 Sealing screw with valve (option) 9 Screw cover safety bracket (only for explosion-proof enclosure, not shown in the drawing) 1) Allow approx. 0 mm (0.79 inch) thread length in addition ) 9 mm (3.6 inch) for minimum distance to permit rotation without indicator 3) 74 mm (.9 inch) for PN ³ 40 (MWP ³ 609 psi) 4) 91 mm (3.6 inch) for PN ³ 40 (MWP ³ 609 psi) 5) 19 mm (8.6 inch) for PN ³ 40 (MWP ³ 609 psi) 6) Approx. 45 mm (1.77 inch) for Pg 13.5 with adapter SITRANS P pressure transmitters, DS III PA and FF series for differential pressure and flow, with process covers for vertical differential pressure lines, dimensions in mm (inch) SITRANS P pressure transmitters, DS III series for differential pressure and flow, with process covers for vertical differential pressure lines Siemens FI US Edition /107

108 Siemens AG 007 Transmitters for gage, absolute and differential pressure, flow and level DS III series for differential pressure and flow SITRANS P pressure transmitters, DS III FF series for differential pressure and flow, with digital indicator beside control keys, dimensions in mm (inch) SITRANS P pressure transmitters, DS III series for differential pressure and flow, with digital indicator beside control keys /108 Siemens FI US Edition

109 Technical specifications SITRANS P, DS III series for level Input Measured variable Spans (infinitely adjustable) or nominal measuring range and max. permissible working pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for level HART Level Span mbar g ( psi g) mbar g ( psi g) mbar g ( psi g) mbar g ( psi g) Maximum working pressure See "Mounting flange" See "Mounting flange" See "Mounting flange" See "Mounting flange" PROFIBUS PA or FOUNDATION Fieldbus Nominal measuring range 50 mbar g (3.63 psi g) 600 mbar g (8.7 psi g) 1600 mbar g (3. psi g) 5000 mbar g (7.5 psi g) Maximum working pressure See "Mounting flange" See "Mounting flange" See "Mounting flange" See "Mounting flange" Lower measuring limit Measuring cell with silicone oil filling -100% of max. span or 30 mbar (0.435 psi a), depending on mounting flange Upper measuring limit 100% of max. span 100% of the max. nominal measuring range Output Output signal ma Digital PROFIBUS PA or FOUNDATION Fieldbus signal Lower limit (infinitely adjustable) 3.55 ma, factory preset to 3.84 ma - Upper limit (infinitely adjustable) 3 ma, factory preset to 0.5 ma or optionally - set to.0 ma Load Without HART communication R B (U H V)/0,03 A in Ω, - U H : Power supply in V With HART communication R B = Ω (SIMATIC PDM) or - R B = Ω (HART Communicator) Physical bus - IEC With polarity reversal protection - Yes Accuracy To EN Reference conditions Increasing characteristic, start-of-scale value 0 bar, stainless steel seal diaphragm, silicone oil filling, room temperature 5 C (77 F)) r: Span ratio (r = max. span / set span) Error in measurement and fixed-point setting (including hysteresis and repeatability) Linear characteristic 0,075% -r 10 0,15% - 10 < r 30 0,3% - 30 < r 100 ( r )% Long-term drift (temperature change ±30 C (±54 F)) Influence of ambient temperature at C ( F) (0.5 r)% every 5 years static pressure max. 70 bar g (1015 psi g) - 50-mbar (3.63 psi) measuring cell (0.5 r + 0.)% (0.4 instead of 0. with 10 < r 30) mbar (8.7 psi) measuring cell (0.3 r + 0.)% (0.4 instead of 0. with 10 < r 30) and 5000 mbar (3. and 7.5 psi) measuring cells at C and C ( F and F) (0.5 r + 0.)% (0.4 instead of 0. with 10 < r 30) - 50 mbar (3.63 psi) measuring cell (0.5 r +0.15)%/10 K double values with 10 < r mbar (8.7 psi) measuring cell (0.15 r +0.15)%/10 K double values with 10 < r and 5000 mbar (3. and 7.5 psi) measuring cells Siemens AG 007 (0.1 r +0.15)%/10 K double values with 10 < r 30 (0.5% every 5 years static pressure max. 70 bar g (1015 psi g) 0,7% 0,5% 0,45% 0.4%/10 K 0.3%/10 K 0.7%/10 K Siemens FI US Edition /109

110 Siemens AG 007 Transmitters for gage, absolute and differential pressure, flow and level DS III series for level SITRANS P, DS III series for level HART PROFIBUS PA or FOUNDATION Fieldbus Influence of static pressure on the zero point - 50 mbar (3.63 psi) measuring cell (0.3 r)% per nominal pressure 0.3% per nominal pressure mbar (8.7 psi) measuring cell (0.15 r)% per nominal pressure 0.15% per nominal pressure and 5000 mbar (3. and 7.5 psi) measuring cells (0.1 r)% per nominal pressure 0.1% per nominal pressure on the span (0.1 r)% per nominal pressure 0.1% per nominal pressure Measured Value Resolution of nominal measuring range Rated operating conditions Degree of protection (to EN 6059) IP65 Process temperature Note: Always take into account assignment of max. permissible working temperature to max. permissible working pressure of the respective flange connection! Measuring cell with silicone oil filling C ( F) - High-pressure side p abs 1bar: C ( F) p abs 1bar: C ( F) - Low-pressure side C ( F) C ( F) in conjunction with dust explosion protection Ambient conditions Ambient temperature - Digital indicators C ( F) Storage temperature C ( F) Climatic class - Condensation Permissible Electromagnetic compatibility - Emitted interference and interference immunity To EN 6136 and NAMUR NE 1 Design Weight (without options) To EN (pressure transmitter with mounting kg ( lb) flange, without tube) To ASME (pressure transmitter with mounting kg ( lb) flange, without tube) Wetted parts materials Low copper die-cast aluminium, GD-AlSi1 or stainless steel precision casting, mat. No Housing material High-pressure side Seal diaphragm of mounting flange Stainless steel, mat. No /316L, Monel, mat. No..4360, Hastelloy B, mat. No..4617, Hastelloy C76, mat. No..4819, Hastelloy C4, mat. No..4610, tantalum, PTFE, ECTFE Measuring cell filling Silicone oil Process connection High-pressure side Flange to EN and ASME Low-pressure side Female thread ¼-18 NPT and flange connection with mounting thread M10 to DIN 1913 or / 16-0 UNF to EN Power supply U H Terminal voltage on transmitter V DC V DC in intrinsically-safe mode Separate 4 V power supply necessary - No Bus voltage Not Ex V With intrinsically-safe operation V Current consumption Basic current (max.) ma Startup current basic current - Yes Max. current in event of fault ma Fault disconnection electronics (FDE) available - Yes Supplied through bus - /110 Siemens FI US Edition

111 Siemens AG 007 Transmitters for gage, absolute and differential pressure, flow and level DS III series for level SITRANS P, DS III series for level Certificate and approvals Classification according to pressure equipment directive (DRGL 97/3/EC) Explosion protection HART For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of Article 3, paragraph 3 (sound engineering practice) Intrinsic safety "i" PTB 99 ATEX 1 - Identification Ex II 1/ G EEx ia/ib IIB/IIC T6 - Permissible ambient temperature C ( F) temperature class T4; C ( F) temperature class T5; C ( F) temperature class T6 - Connection To certified intrinsically-safe circuits with maximum values: U i = 30 V, I i = 100 ma, P i = 750 mw; R i = 300 Ω FISCO supply unit: U o = 17.5 V, I o = 380 ma, P o = 5.3 W Linear barrier: U o = 4 V, I o = 50 ma, P o = 1. W - Effective internal inductance/capacitance L i = 0.4 mh, C i = 6 nf L i = 7 µh, C i = 1.1 nf Explosion-proof "d" PTB 99 ATEX Identification Ex II 1/ G EEx d IIC T4/T6 - Permissible ambient temperature C ( F) temperature class T4; C ( F) temperature class T6 - Connection To circuits with values: U H = V DC To circuits with values: U H = V DC Dust explosion protection for zone 0 PTB 01 ATEX Identification Ex II 1 D IP65 T 10 C Ex II 1/ D IP65 T 10 C - Permissible ambient temperature C ( F) - Max.surface temperature 10 C (48 F) - Connection To certified intrinsically-safe circuits with maximum values: U i = 30 V, I i = 100 ma, P i = 750 mw, R i = 300 Ω FISCO supply unit: U o = 17.5 V, I o = 380 ma, P o = 5.3 W Linear barrier: U o = 4 V, I o = 50 ma, P o = 1. W - Effective internal inductance/capacitance L i = 0.4 mh, C i = 6 nf L i = 7 µh, C i = 1.1 nf Dust explosion protection for zone 1/ PTB 01 ATEX Identification Ex II D IP65 T 10 C - Connection To circuits with values: U H = V DC; P max = 1. W PROFIBUS PA or FOUNDATION Fieldbus To circuits with values: U H = V DC; P max = 1. W Type of protection "n" (zone ) TÜV 01 ATEX 1696 X Planned - Identification Ex II 3 G EEx na L IIC T4/T5/T6 - Explosion protection to FM Certificate of Compliance Identification (XP/DIP) or (IS); (NI) CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; CL I, ZN 0/1 AEx ia IIC T4...T6; CL I, DIV, GP ABCD T4...T6; CL II, DIV, GP FG; CL III Explosion protection to CSA Certificate of Compliance Identification (XP/DIP) or (IS) CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; Ex ia IIC T4...T6; CL I, DIV, GP ABCD T4...T6; CL II, DIV, GP FG; CL III Siemens FI US Edition /111

112 Transmitters for gage, absolute and differential pressure, flow and level DS III series for level HART communication HART communication Ω Protocol HART Version 5.x Software for computer SIMATIC PDM PROFIBUS PA communication Simultaneous communication with master class (max.) The address can be set using Cyclic data usage Output byte Input byte Internal preprocessing Device profile Function blocks Analog input - Adaptation to customer-specific process variables - Electrical damping T 63, adjustable 4 Configuration tool or local operation (standard setting address 16) 5 (one measuring value) or 10 (two measuring values) 0, 1, or (register operating mode and reset function for metering) PROFIBUS PA Profile for Process Control Devices Version 3.0, Class B Yes, linearly rising or falling characteristic s - Simulation function Input /Output - Failure mode Can be parameterized (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively Register (totalizer) Can be reset, preset, optional direction of counting, simulation function of register output - Failure mode Can be parameterized (summation with last good value, continuous summation, summation with incorrect value) - Limit monitoring One upper and lower warning limit and one alarm limit respectively Physical block 1 Transducer blocks Pressure transducer block - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Characterizer Max. 30 points - Square-rooted characteristic Yes for flow measurement - Gradual volume suppression Parameterizable and implementation point of square-root extraction - Simulation function for measured pressure value and sensor temperature Constant value or over parameterizable ramp function Siemens AG 007 Communication FOUNDATION Fieldbus Function blocks 3 function blocks analog input, 1 function block PID Analog input - Adaptation to customer-specific process variables - Electrical damping T 63, adjustable Yes, linearly rising or falling characteristic s - Simulation function Output/input (can be locked within the device with a bridge) - Failure mode Can be parameterized (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively - Square-rooted characteristic Yes for flow measurement PID Standard FF function block Physical block 1 Resource block Transducer blocks 1 transducer block Pressure with calibration, 1 transducer block LCD Pressure transducer block - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Simulation function: Measured pressure value, sensor temperature and electronics temperature Constant value or over parameterizable ramp function Mounting flange Nom. diam. Nom. press. To EN DN 80 PN 40 - DN 100 PN 16, PN 40 To ASME B inch Class 150, class inch Class 150, class 300 /11 Siemens FI US Edition

113 Selection and Ordering data SITRANS P pressure transmitters for level series DS III HART Transmitters for gage, absolute and differential pressure, flow and level DS III series for level Order No. 7 M F Y Measuring cell filling Measuring cell cleaning Silicone oil Standard 1 Span mbar ( psi) D mbar ( psi) E mbar ( psi) F bar ( psi) G Process connection of low-pressure side Female thread ¼-18 NPT with flange connection Mounting thread M10 to DIN Mounting thread 7 / 16-0 UNF to EN Non-wetted parts materials Process flange screws Electronics housing Stainless steel Die-cast aluminium Stainless steel Stainless steel precision 3 casting 1) Version Standard version 1 International version, English label inscriptions, documentation in 5 languages on CD Explosion protection Without A With ATEX, Type of protection: - "Intrinsic safety (EEx ia)" B - "Explosion-proof (EEx d)" ) F) D - "Intrinsic safety and explosion-proof F) P enclosure (EEx ia + EEx d)" 3) - "Ex na/nl (zone )" E - "Intrinsic safety, explosion-proof enclosure F) R and dust explosion protection (EEx ia + EEx d + Zone 1D/D)" 3) With FM + CSA, Type of protection: - "Intrinsic safety and explosion-proof F) N C (is + xp)" ) Electrical connection / cable entry Screwed gland Pg ) A Screwed gland M0x1.5 B Screwed gland ½-14 NPT C Han 7D plug (plastic housing) incl. mating F) D connector 4) M1 connectors (metal) 5) F Display without (digital indicator hidden, setting: ma) 1 With visible digital indication 6 With customer-specific digital indication (setting 7 as specified, Order code "Y1" or required) Ordering information: 1st order item: Pressure transmitter 7MF nd order item: Mounting flange 7MF Ordering example: Item line 1: 7MF4633-1EY0-1AA1-Z B line: Y01 C line: Y01: 80 to 143 mbar (1.16 to.1 psi) Item line : 7MF491-3GE01 Power supply units see "SITRANS I power supply units and isolation amplifiers". Included in delivery of the device: Brief instructions (Leporello) CD-ROM with detailed documentation Sealing plug(s) or sealing screw(s) for the process flanges(s) Siemens AG 007 1) Not together with Electrical connection Screwed gland Pg 13.5 and Han7D plug. ) Without cable gland, with blanking plug. 3) With enclosed cable gland EEx ia and blanking plug. 4) Not together with type of protection "Explosion-proof" and type of protection "Ex na". 5) Not together with types of protection "Explosion-proof" or "Intrinsic safety and explosion-proof" F) Subject to export regulations AL: 9I999, ECCN: N. Siemens FI US Edition /113

114 Transmitters for gage, absolute and differential pressure, flow and level DS III series for level Selection and Ordering data Order No. SITRANS P pressure transmitter for level DS III PA series (PROFIBUS PA) 7 M F DS III FF series (FOUNDATION Fieldbus) 7 M F Y Nominal measuring range 50 mbar (3.6 psi) D 600 mbar (8.70 psi) E 1600 mbar (3. psi) F 5 bar (7.5 psi) G Process connection of low-pressure side Female thread ¼-18 NPT with flange connection Mounting thread M10 to DIN Mounting thread 7 / 16-0 UNF to EN Non-wetted parts materials Process flange screws Electronics housing Stainless steel Die-cast aluminium Stainless steel Stainless steel precision 3 casting Version Standard version 1 International version, English label inscriptions, documentation in 5 languages on CD Explosion protection Without A With CENELEC, Type of protection: - "Intrinsic safety (EEx ia)" B - "Explosion-proof (EEx d)" 1) F) D - "Intrinsic safety and explosion-proof e F) P nclosure (EEx ia + EEx d)" ) - "Ex na/nl (zone)" E - "Intrinsic safety, explosion-proof enclosure F) R and dust explosion protection (EEx ia + EEx d + Zone 1D/D)" ) (not for DS III FF) With FM + CSA, Type of protection: - "Intrinsic safety and explosion-proof F) N C (is + xp)" ) Electrical connection / cable entry Screwed gland M0x1.5 B Screwed gland ½-14 NPT C Plug M1 incl. mating connector 3) F Display Without (digital display hidden) 1 With visible digital indication 6 With customer-specific digital indication (setting 7 as specified, Order code "Y1" or required) Ordering information: 1st order item: Pressure transmitter 7MF nd order item: Mounting flange 7MF Ordering example: Item line 1: 7MF4634-1EY0-1AA1 Item line : 7MF491-3GE01 Included in delivery of the device: Brief instructions (Leporello) CD-ROM with detailed documentation Sealing plug(s) or sealing screw(s) for the process flanges(s) 1) Without cable gland, with blanking plug. ) With enclosed cable gland EEx ia and blanking plug. 3) Not together with types of protection "Explosion-proof" and "Intrinsic safety and explosion-proof" F) Subject to export regulations AL: 9I999, ECCN: N. Siemens AG 007 Selection and Ordering data Order code Further designs HART PA FF Add "-Z" to Order No. and specify Order code. O-rings for process flanges on low-pressure side (instead of FPM (Viton)) PTFE (Teflon) A0 FEP (with silicone core, approved for food) A1 FFPM (Kalrez, compound 4079) A NBR (Buna N) A3 Plug Han 7D (metal, gray) A30 Han 8U (instead of Han 7D) A31 Sealing screws ¼-18 NPT, with valve in material of process A40 flanges Cable sockets for M1 connectors (metal) A50 Rating plate inscription (instead of German) English B11 French B1 Spanish B13 Italian B14 English rating plate B1 Pressure units in inh O or psi Manufacturer's test certificate M C11 To DIN 55350, Part 18 and to ISO 840 Acceptance test certificate C1 To EN Factory certificate C14 To EN "Functional Safety (SIL)" certificate C0 "PROFIsafe" certificate and protocol C1 Setting of upper limit of output signal to D05.0 ma Type of protection IP68 D1 (not together with PROFIBUS plug M1) Supplied with oval flange D37 F) (1 item), PTFE packing and stainless steel screws in thread of process flange Use on zone 1D / D E01 (only together with type of protection "Intrinsic safety (EEx ia)") Use on zone 0 E0 (only together with type of protection "Intrinsic safety (EEx ia)") Overfilling safety device for flammable E08 and non-flammable liquids (max. PN 3 (MVWP 464 psi), basic device with type of protection "Intrinsic safety (EEx ia)") Explosion-proof "Intrinsic safety" to E5 INMETRO (Brazil) (only for transmitter 7MF B..) Explosion-proof "Intrinsic safety" to E55 NEPSI (China) (only for transmitter 7MF B..) Explosion protection "Explosion-proof" to E56 NEPSI (China) (only for transmitter 7MF D..) Explosion-proof "Zone " to NEPSI (China) E57 (only for transmitter 7MF E..) Interchanging of process connection side H01 /114 Siemens FI US Edition

115 Transmitters for gage, absolute and differential pressure, flow and level DS III series for level Selection and Ordering data Order code Selection and Ordering data Order No.Ord. code Additional data HART PA FF Mounting flange 7 M F Directly mounted on the SITRANS P pressure transmitter (converter part) for level, for DS III series Add "-Z" to Order No. and specify Order code. Measuring range to be set Y01 Specify in plain text (max. 5 digits): Y01:... up to... mbar, bar, kpa, MPa, psi Measuring point number (TAG No.) Y15 Max. 16 characters, specify in plain text: Y15:... Measuring point text Y16 Max. 7 characters, specify in plain text: Y16:... Entry of HART address (TAG) Y17 Max. 8 characters, specify in plain text: Y17:... Setting of pressure indicator in pressure Y1 units Specify in plain text (standard setting: ma): Y1: mbar, bar, kpa, MPa, psi,... Note: The following pressure units can be selected: bar, mbar, mm H O *), inh O *), fth O *), mmhg, inhg, psi, Pa, kpa, MPa, g/cm, kg/cm, Torr, ATM or % *) ref. temperature 0 C Setting of pressure indicator in Y 1) non-pressure units + Y01 Specify in plain text: Y:... up to... l/min, m 3 /h, m, USgpm,... (specification of measuring range in pressure units "Y01" is essential, unit with max. 5 characters) Preset bus address Y5 Specify in plain text (standard setting: 16) Y5:... Only "Y01", "Y1", "Y", "Y5" and "D05" can be factory preset = available 1) Not together with over-filling safety device for flammable and non-flammable liquids (Order code "E08") Siemens AG 007 Connection acc. to EN Nom. diam. Nom. press. DN 80 PN 40 D DN 100 PN 16 G PN 40 H Connection acc. to ASME B16.5 Nom. diam. Nom. press. 3 inch Class 150 Q Class 300 R 4 inch Class 150 T Class 300 U Other version, add Order code and plain text: Z J 1 Y Nominal diameter:...; Nominal pressure:... Wetted parts materials Stainless steel 316L A - Coated with PFA D - Coated with PTFE E 0 - Coated with ECTFE 1) F Monel 400, mat. No G Hastelloy B, mat. No H Hastelloy C76, mat. No J Hastelloy C4, mat. No U Tantalum K Other version, add Z K 1 Y Order code and plain text: material of parts in contact with the medium:... Sealing face, see "Technical specifications" Tube length Without 0 50 mm (1.97 inch) mm (3.94 inch) 150 mm (5.90 inch) 3 00 mm (7.87 inch) 4 Other version: add 9 L 1 Y Order code and plain text: Tube length:... Filling liquid Silicone oil M5 1 Silicone oil M50 High-temperature oil 3 Halocarbon oil (for O measurements) 4 Glycerin / water ) 6 Food oil (FDA-listed) 7 Other version, add 9 M 1 Y Order code and plain text: filling liquid:... 1) For vacuum on request ) Not suitable for use in low-pressure range Siemens FI US Edition /115

116 Transmitters for gage, absolute and differential pressure, flow and level DS III series for level Selection and Ordering data Further designs Add "-Z" to Order No. and specify Order code. Order code HART PA and FF Flame flashover lock-out A01 For mounting on zone 0 (including documentation) Manufacturer's test certificate M C11 To DIN 55350, Part 18 and to ISO 840 Acceptance test certificate C1 To EN Vacuum-proof design V04 (for use in low-pressure range) Calculation of span of associated Y05 pressure transmitter (enclose filled-in questionnaire with order) Note: suffix "Y01" required with pressure transmitter! = available Siemens AG 007 /116 Siemens FI US Edition

117 Dimensional drawings approx. 30 (1.18) 5) Transmitters for gage, absolute and differential pressure, flow and level DS III series for level 100 (3.94) Siemens AG (5.67) 51 (.0) 74 (.9) 15 (0.6) 3 9 L 77 (3) 4) 5 1) 165 (6.5) 8 d 4 d 5 k D (.1) 108 (4.5) approx. 96 (3.78) n x d 1 Process connection of low pressure side ¼-18 NPT (EN ) Blanking plug 3 Electrical connection: screwed gland Pg 13.5 (adapter) ) 3), screwed gland M0x1.5, screwed gland ½-14 NPT or Han 7D/ Han 8U plug ) 3) 4 Terminal side 5 Electronics side, digital display (longer overall length for cover with window) 6 Protective cover over keys 8 Sealing screw with valve (option) 9 Screw cover safety bracket (only for type of protection "Explosion-proof enclosure", not shown in the drawing) 1) Allow approx. 0 mm (0.79 inch) thread length in addition ) Not with type of protection "Explosion-proof enclosure" 3) Not with type of protection "FM + CSA [is + xp]" 4) 9 mm (3.6 inch) for minimum distance to permit rotation without indicator 5) Approx. 45 mm (1.77 inch) for Pg 13.5 with adapter b f 4 1) 6 Space for rotation of housing 5 1) SITRANS P pressure transmitters, DS III HART series for level, including mounting flange, dimensions in mm (inch) Connection to EN Nom. diam. Nom. press. b D d d d 4 d 5 d M f k n L mm mm mm mm mm mm mm mm mm mm mm DN 80 PN ) , 50, 100, DN 100 PN or 00 PN Connection to ASME B16.5 Nom. diam. Nom. press. b D d d 4 d 5 d M f k n L lb/sq.in. inch inch inch inch inch inch inch inch inch (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm).81 1) (7) (1.6) (15.4) 3 inch (3.8) (8.6) 4 inch (3.8) (31.7) 7.5 (190.5) 8.5 (09.5) 9 (8.5) 10 (54) d: Internal diameter of gasket to DIN 690 d M : Effective diaphragm diameter 0.75 (19.0) 0.87 (.) 0.75 (19.0) 0.87 (.) 5 (17) 5 (17) 6.19 (157.) 6.19 (157.) 3 (76) 3 (76) 3.69 (94) 3.69 (94).81 1) (7) 3.5 (89) 3.5 (89) 0.06 (1.6) 0.06 (1.6) 0.06 (1.6) 6.69 (168.3) 7.5 (190.5) 7.88 (00) 1) 89 mm = 3½ inch with tube length L = ,, 3.94, 5.94 or 7.87 (0, 50, 100, 150 or 00) Siemens FI US Edition /117

118 Transmitters for gage, absolute and differential pressure, flow and level DS III series for level approx. 30 (1.18) 185 Siemens AG (3.94) 144 (5.67) 6 51 (.0) 74 (.9) 15 (0.6) 3 9 L 77 (3) 4) 5 1) 165 (6.5) 8 d 4 d 5 k D 1 54 (.1) 108 (4.5) n x d 1 Process connection of low pressure side ¼-18 NPT (EN 61518) Blanking plug 3 Electrical connection: - screwed connection M0x1,5 3), - screwed connection ½-14 NPT or ) 3) - PROFIBUS plug M1 4 Terminal side 5 Electronics side, digital display (longer overall length for cover with window) 6 Protective cover over keys 8 Sealing screw with valve (option) 9 Screw cover safety bracket (only for "explosion-proof enclosure", not shown in the drawing) 1) Allow approx. 0 mm (0.79 inch) thread length in addition ) Not with type of protection "Explosion-proof enclosure" 3) Not with type of protection "FM + CSA [is + xp]" 4) 9 mm (3.6 inch) for minimum distance to permit rotation with indicator b f 4 1) 6 Space for rotation of housing 5 1) SITRANS P pressure transmitters, DS III PA and FF series for level, including mounting flange, dimensions in mm (inch) Connection to EN Nom. diam. Nom. press. b D d d d 4 d 5 d M f k n L mm mm mm mm mm mm mm mm mm mm mm DN 80 PN ) , 50, 100, DN 100 PN or 00 PN Connection to ASME B16.5 Nom. diam. Nom. press. b D d d 4 d 5 d M f k n L lb/sq.in. inch inch inch inch inch inch inch inch inch (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) 3 inch (3.8) (8.6) 4 inch (3.8) (31.7) 7.5 (190.5) 8.5 (09.5) 9 (8.5) 10 (54) d: Internal diameter of gasket to DIN 690 d M : Effective diaphragm diameter 0.75 (19.0) 0.87 (.) 0.75 (19.0) 0.87 (.) 5 (17) 5 (17) 6.19 (157.) 6.19 (157.) 3 (76) 3 (76) 3.69 (94) 3.69 (94).81 1) (7).81 1) (7) 3.5 (89) 3.5 (89) 0.06 (1.6) 0.06 (1.6) 0.06 (1.6) 0.06 (1.6) 6 (15.4) 6.69 (168.3) 7.5 (190.5) 7.88 (00) 1) 89 mm = 3½ inch with tube length L = ,, 3.94, 5.94 or 7.87 (0, 50, 100, 150 or 00) /118 Siemens FI US Edition

119 Overview Siemens AG 007 SITRANS P Accessories Supplementary electronics for 4-wire connection Structural design Dimensions (W x H x D) in mm (inch) Electrical connection 80 x 10 x 60 (3.15 x 4.7 x.36) Screw terminals (Pg 13.5 cable inlet) or Han 7D / Han 8U plug Power supply Supply voltage 30 V AC ( %, Hz, approx. 6 VA) or 4 V AC/DC (4 V AC ± 10%, Hz, approx. 3 VA) Permissible ripple (within the specified Approx..5 V pp limits) Dimensional drawings SITRANS P pressure transmitter with supplementary electronics for 4- wire connection Direct connection of the supplementary electronics to a SITRANS P pressure transmitter from the DS III HART series produces a transmitter for four-wire connection. The supplementary electronics cannot be attached to explosionprotected pressure transmitters. The supplementary electronics is fitted in a light metal housing which is mounted on the left side of the pressure transmitter. Note on ordering: The supplementary electronics has to be be ordered through the supplementary options of the pressure transmitter in question. Technical specifications SITRANS P pressure transmitters with supplementary electronics for fourwire connection, dimension drawing, dimensions in mm SITRANS P, supplementary electronics for 4-wire connection Output Schematics Output signal ma or ma Load Max. 750 Ω Terminals Voltage measurement Linear (square-rooting in transmitter if necessary) I U SL a H - Electrical isolation Between power supply and input/ output 6 7 SL Measuring accuracy To EN HAN 8U/7D plug 5 1 Conformity error (in addition to 0.15% of set span 4 3 transmitter) Influence of ambient temperature 0.1% per 10 K + I a - U H Power supply effect 0.1% per 10% change in voltage or frequency plugs SL Load effect 0.1% per 100% change Rated conditions Ambient temperature C ( F) + I a - U H Storage temperature C ( F) AC 30 V Han 7D Han 7D UC 4 V Han 7D Han 8U Degree of protection IP54 to EN 6059 Electromagnetic compatibility EN 50081, EN 5008 I a Output current SL Protective earth conductor U H Power supply (EMC) Supplementary electronics for 4-wire connection, connection diagram Siemens FI US Edition /119

120 SITRANS P Accessories Supplementary electronics for 4-wire connection Siemens AG 007 Selection and Ordering data Supplementary electronics for 4-wire connection Order No. of the transmitter 7MF AA. add "-Z" and Order code. Power supply Electrical connection 4 V AC/DC Terminals; Pg screwed glands, to left Han 7D/Han 8U plugs incl. mating connector, to left 1 Han 7D plug incl. mating connector, angled Terminals; 1 Pg screwed gland, downwards 1 Han 8U plug incl. mating connector, downwards (observe arrangement of plug and differential pressure line) 30 V AC Terminals; Pg screwed glands, to left Han 7D plugs incl. mating connector, to left Output current ma ma 1 Order code V Selection and Ordering data Accessories Instruction Manual Order No. A5E /10 Siemens FI US Edition

121 Selection and Ordering data Replacement measuring cell for pressure for SITRANS P, DS III, DS III PA and DS III FF series SITRANS P Accessories Accessories / spare parts for SITRANS P P300 and DS III series Order No. 7 M F D C 0 Measuring cell filling Measuring cell cleaning Silicone oil Standard 1 Inert liquid Grease-free 3 Measured span bar g ( psi g) B bar g ( psi g) C bar g ( psi g) D bar g ( psi g) E bar g ( psi g) F bar g ( psi g) G Wetted parts materials Seal diaphragm Process connection Stainless steel Stainless steel A Hastelloy Stainless steel F) B Hastelloy Hastelloy F) C Process connection Connection shank G½A to EN Female thread ½-14 NPT 1 Oval flange made of stainless steel, max. span 160 bar (30 psi) - Mounting thread 7 / 16-0 UNF to EN Mounting thread M10 to DIN Further designs Order code Please add "-Z" to Order No. and specify Order code. Acceptance test certificate C1 to EN Siemens AG 007 Selection and Ordering data Order No. Replacement measuring cell for absolute pressure (from the pressure series) for SITRANS P, DS III, DS III PA and DS III FF series F) 7 M F D C 0 Measuring cell filling Measuring cell cleaning Silicone oil Standard 1 Inert liquid Grease-free 3 Measured span mbar a ( psi a) D mbar a ( psi a) F bar a ( psi a) G bar a ( psi a) H Wetted parts materials Seal diaphragm Process connection Stainless steel Stainless steel A Hastelloy Stainless steel B Hastelloy Hastelloy C Process connection Connection shank G½A to EN Female thread ½-14 NPT 1 Oval flange made of stainless steel, max. span 160 bar (30 psi) - Mounting thread 7 / 16-0 UNF to EN Mounting thread M10 to DIN Further designs Order code Please add "-Z" to Order No. and specify Order code. Acceptance test certificate C1 to EN F) Subject to export regulations AL: 9I999, ECCN: N. F) Subject to export regulations AL: 9I999, ECCN: N. Siemens FI US Edition /11

122 SITRANS P Accessories Accessories / spare parts for SITRANS P P300 and DS III series Selection and Ordering data Order No. Spare parts / Accessories Replacement measuring cell for absolute pressure (from the differential pressure series) for SITRANS P, DS III, DS III PA and DS III FF series F) 7 M F D C 0 Measuring cell filling Measuring cell cleaning Silicone oil Standard 1 Inert liquid Grease-free 3 Measured span mbar a ( psi a) E) D mbar a ( psi a) E) F bar a ( psi a) E) G bar a ( psi a) H bar a ( psi a) K E Wetted parts materials Seal diaphragm Parts of measuring cell Stainless steel Stainless steel A Hastelloy Stainless steel B Hastelloy Hastelloy C Tantalum Tantalum E Monel Monel E) H Gold Gold L Process connection Female thread ¼-18 NPT with flange connection Sealing screw opposite process connection - Mounting thread M10 to DIN Mounting thread 7 / 16-0 UNF to EN Vent on side of process flange 1) - Mounting thread M10 to DIN Mounting thread 7 / 16-0 UNF to EN Non-wetted parts materials Stainless steel process flange screws Further designs Order code Please add "-Z" to Order No. and specify Order code. O-rings for process flanges (instead of FPM (Viton)) PTFE (Teflon) A0 FEP (with silicone core, approved for food) A1 FFPM (Kalrez, compound 4079) A NBR (Buna N) A3 Acceptance test certificate C1 to EN Process connection G½A D16 Remote seal flanges D0 (not together with K01, K0 and K04) Vent on side for gas measurements H0 Process flanges without K00 with process flange made of - Hastelloy K01 - Monel K0 - Stainless steel with PVDF insert K04 max. PN 10 (MWP 145 psi) max. temperature of medium 90 C (194 F) 1) Not for span " bar ( psi)" E) Combinations of the versions marked with E) are subject to the export regulations AL: B30, ECCN: N. F) Subject to export regulations AL: 9I999, ECCN: N. Siemens AG 007 Selection and Ordering data Order No. Spare parts / Accessories Replacement measuring cell for differential pressure and PN 3/160 (MWP 464/30 psi) for SITRANS P, DS III, DS III PA and DS III FF series 7 M F D C 0 Measuring cell filling Measuring cell cleaning Silicone oil Standard 1 Inert liquid Grease-free 3 Measured span PN 3 (MWP 464 psi) mbar 1) ( inh O) B PN 160 (MWP 30 psi) mbar ( inh O) C mbar ( inh O) D mbar ( inh O) E mbar ( inh O) F mbar ( inh O) G bar ( psi) H Wetted parts materials (stainless steel process flanges) Seal diaphragm Parts of measuring cell Stainless steel Stainless steel A Hastelloy Stainless steel F) B Hastelloy Hastelloy F) C Tantalum ) Tantalum E Monel ) Monel F) H Gold ) Gold L Process connection Female thread ¼-18 NPT with flange connection Sealing screw opposite process connection - Mounting thread M10 to DIN Mounting thread 7 / 16-0 UNF to EN Vent on side of process flange - Mounting thread M10 to DIN Mounting thread 7 / 16-0 UNF to EN Non-wetted parts materials Stainless steel process flange screws Further designs Order code Please add "-Z" to Order No. and specify Order code. O-rings for process flanges (instead of FPM (Viton)) PTFE (Teflon) A0 FEP (with silicone core, approved for food) A1 FFPM (Kalrez, compound 4079) A NBR (Buna N) A3 Acceptance test certificate C1 to EN Remote seal flanges D0 (not together with K01, K0 and K04) Vent on side for gas measurements H0 Stainless steel process flanges for vertical H03 differential pressure lines (not together with K01, K0 and K04) Process flanges without K00 with process flange made of - Hastelloy F) K01 - Monel F) K0 - Stainless steel with PVDF insert K04 max. PN 10 (MWP 145 psi) max. temperature of medium 90 C (194 F) 1) Not suitable for connection of remote seal ) Only together with max. spans 50, 1600, 5000 and mbar (3.63, 3., 7.5 and 435 psi). F) Subject to export regulations AL: 9I999, ECCN: N. /1 Siemens FI US Edition

123 Selection and Ordering data Spare parts / Accessories SITRANS P Accessories Accessories / spare parts for SITRANS P P300 and DS III series Order No. Replacement measuring cell for differential pressure and PN 40 (MWP 609 psi) for SITRANS P, DS III, DS III PA and 7 M F D C 0 DS III FF series Measuring cell filling Measuring cell cleaning Silicone oil Standard 1 Measured span mbar ( inh O) D mbar ( inh O) E mbar ( inh O) F mbar ( inh O) G bar ( psi) H Wetted parts materials (stainless steel process flanges) Seal diaphragm Parts of measuring cell Stainless steel Stainless steel A Hastelloy Stainless steel F) B Gold 1) Gold L Process connection Female thread ¼-18 NPT with flange connection Sealing screw opposite process connection - Mounting thread M1 to DIN Mounting thread 7 / 16-0 UNF to EN Vent on side of process flange - Mounting thread M1 to DIN Mounting thread 7 / 16-0 UNF to EN Non-wetted parts materials Stainless steel process flange screws Further designs Order code Please add "-Z" to Order No. and specify Order code. O-rings for process flanges (instead of FPM (Viton)) PTFE (Teflon) A0 FEP (with silicone core, approved for food) A1 FFPM (Kalrez, compound 4079) A NBR (Buna N) A3 Acceptance test certificate C1 to EN Stainless steel process flanges for vertical differential pressure lines H03 without process flanges K00 Siemens AG 007 Selection and Ordering data Order No. Spare parts / Accessories Replacement measuring cell for level for SITRANS P, DS III, DS III PA and DS III FF series 7 M F D C 0 Measuring cell filling Measuring cell cleaning Silicone oil Standard 1 Rated measuring range 50 mbar (3.63 psi) D 600 mbar (8.70 psi) E 1600 mbar (3. psi) F 5 bar (7.5 psi) G Wetted parts materials (stainless steel process flanges) Seal diaphragm Parts of measuring cell Stainless steel Stainless steel A Process connection of low-pressure side Female thread ¼-18 NPT with flange connection Sealing screw opposite process connection - Mounting thread M10 to DIN Mounting thread 7 / 16-0 UNF to EN Non-wetted parts materials Stainless steel process flange screws Further designs Order code Please add "-Z" to Order No. and specify Order code. O-rings for process flanges (instead of FPM (Viton)) PTFE (Teflon) A0 FEP (with silicone core, approved for food) A1 FFPM (Kalrez, compound 4079) A NBR (Buna N) A3 Acceptance test certificate C1 to EN without process flanges K00 1) Not together with max. span 600 mbar (40.9 inh O) F) Subject to export regulations AL: 9I999, ECCN: N. Siemens FI US Edition /13

124 SITRANS P Accessories Accessories / spare parts for SITRANS P P300 and DS III series Selection and Ordering data Order No. Spare parts / Accessories Mounting bracket and mounting parts for pressure transmitters DS III, DS III PA and DS III FF series (7MF C.) for absolute pressure transmitters DS III, DS III PA and DS III FF series (7MF C.) made of steel 7MF4997-1AB made of stainless steel 7MF4997-1AH Mounting bracket and mounting parts for pressure transmitters DS III, DS III PA and DS III FF series (7MF A., -..B. and -..D.) for absolute pressure transmitters DS III, DS III PA and DS III FF series (7MF A., -..B. and -..D.) Made of steel 7MF4997-1AC Made of stainless steel } 7MF4997-1AJ Mounting bracket and mounting parts for differential pressure transmitters with flange thread M10 DS III, DS III PA and DS III FF series (7MF and 7MF ) made of steel 7MF4997-1AD made of stainless steel } 7MF4997-1AK Mounting bracket and mounting parts for differential pressure transmitters with flange thread M1 DS III, DS III PA and DS III FF series (7MF ) made of steel 7MF4997-1AE made of stainless steel 7MF4997-1AL Mounting bracket and mounting parts for differential and absolute pressure transmitters with flange thread 7/16-0 UNF DS III, DS III PA and DS III FF series (7MF , 7MF and 7MF ) made of steel 7MF4997-1AF made of stainless steel 7MF4997-1AM Cover Made of die-cast aluminium, including gasket, for DS III, DS III PA and DS III FF series without window F) 7MF4997-1BB with window } 7MF4997-1BE F) Cover Made of stainless steel, including gasket, for DS III, DS III PA and DS III FF series without window F) 7MF4997-1BC with window F) 7MF4997-1BF Analog indicator Scale % 7MF4997-1BN Customer-specific scale divisions as specified in plain text Y0:... 7MF4997-1BP-Z Digital indicator Including mounting material 7MF4997-1BR for DS III, DS III PA and DS III FF series Measuring-point label without inscription (5 off) 7MF4997-1CA with inscription (1 off) Data according to Y01 or Y0, Y15 and Y16 (see "SITRANS P pressure transmitters") Mounting screws for measuring-point label, earthing and connection terminals or for digital indicator (50 off) 7MF4997-1CB-Z Y..:... 7MF4997-1CD Siemens AG 007 Selection and Ordering data Order No. Sealing screws (1 set = off) for process flange made of stainless steel 7MF4997-1CG made of Hastelloy F) 7MF4997-1CH Vent valves complete (1 set = off) made of stainless steel } 7MF4997-1CP made of Hastelloy F) 7MF4997-1CQ Electronics for DS III series 7MF4997-1DK for DS III PA series 7MF4997-1DL for DS III FF series 7MF4997-1DM Connection board for DS III series 7MF4997-1DN for DS III PA and DS III FF series 7MF4997-1DP O-rings for process flanges made of FPM (Viton) F) 7MF4997-DA PTFE (Teflon) F) 7MF4997-DB FEP (with silicone core, approved for food) F) 7MF4997-DC FFPM (Kalrez, compound 4079) F) 7MF4997-DD NBR (Buna N) F) 7MF4997-DE Weldable sockets for PMC connection for DS III and P300 series PMC Style Standard: Thread 1½ 7MF4997-HA PMC Style Mini bolt: front-flush 1 7MF4997-HB Sealing rings for PMC connection (packing unit: 5 pcs) Sealing ring made of PTFE for PMC Style F) 7MF4997-HC Standard: Thread 1½" Sealing ring made of Viton for PMC Style F) 7MF4997-HD Minibolt: front-flush 1 Welding adapter for PMC connection to prevent the weldable socket to warp during welding, for: PMC Style Standard: Thread 1½ 7MF4997-HE PMC Style Mini bolt: front-flush 1 7MF4997-HF Mounting bracket and mounting parts for P300 Made of stainless steel 7MF8997-1AA Lid without window for P300 Gasket not included 7MF8997-1BA Lid with glass window for P300 Gasket not included 7MF8997-1BD NBR housing gasket for P300 7MF8997-1BG Measuring point label for P300 Unlabeled 7MF8997-1CA Cable gland for P300 Metal F) 7MF8997-1EA Plastic (blue) F) 7MF8997-1EB } Available ex stock F) Subject to export regulations AL: 9I999, ECCN: N. /14 Siemens FI US Edition

125 Selection and Ordering data Order No. Instruction Manual 1) for P300 series with HART communication -German A5E English A5E French A5E Spanish A5E Italian A5E Leporello German/English A5E for P300 series with PROFIBUS PA communication -German A5E English A5E French A5E Spanish A5E Italian A5E Leporello German/English A5E for DS III series -German A5E English A5E French A5E Spanish A5E Italian A5E for DS III PA series -German A5E English A5E French A5E Spanish A5E Italian A5E for DS III FF series -German A5E English (planned) A5E French (planned) A5E Spanish (planned) A5E Italian (planned) A5E Brief instructions (Leporello) for DS III series, German, English for DS III PA series, German, English for DS III FF series, German, English SITRANS P Accessories Accessories / spare parts for SITRANS P P300 and DS III series A5E A5E A5E CD with documentation D) A5E for P300, DS III, DS III PA and DS III FF series German, English, French, Italian, Spanish Instruction Manual for replacement of electronics, measuring cell and connection board German/English A5E HART modem with RS3 interface } 7MF4997-1DA D) with USB interface } 7MF4997-1DB D) Supplementary electronics for 4-wire connection see page /119 } Available ex stock Power supply units see "SITRANS I power supply units and input isolators". Siemens AG 007 1) You can download the Instruction Manuals free-of-charge from the Internet site D) Subject to export regulations AL: N, ECCN: EAR99H. F) Subject to export regulations AL: 9I999, ECCN: N. Siemens FI US Edition /15

126 Siemens AG 007 SITRANS P Accessories Factory-mounting of valve manifolds on SITRANS P transmitters Overview SITRANS P transmitters P300 for relative and absolute pressure, DS III for relative and absolute pressure (both designs) and DS III for differential pressure can be delivered factory-fitted with the following valve manifolds: 7MF9011-4EA and 7MF9011-4FA valve manifolds for relative pressure and absolute pressure transmitters 7MF9411-5BA and 7MF9411-5CA valve manifolds for absolute pressure and differential pressure transmitters Design The 7MF9011-4EA valve manifolds are sealed with gaskets made of PTFE between transmitter and the valve manifold as standard. Soft iron, stainless steel and copper gaskets are also available for sealing purposes if preferred. The 7MF9011-4FA valve manifolds are sealed with PTFE sealing tape between the transmitter and the valve manifold. The 7MF9411-5BA and 7MF9411-5CA valve manifolds are sealed with PTFE sealing rings between the transmitter and the valve manifold. Once installed, the complete unit is checked under pressure for leaks and is certified leak-proof with a factory certificate to EN All valve manifolds should preferably be secured with the respective mounting brackets. The transmitters are mounted on the valve manifold and not on the unit itself. If you order a mounting bracket when choosing the option "Factory mounting of valve manifolds", you will receive a mounting bracket for the valve manifold instead of a bracket for mounting the transmitter. If you order an acceptance test certificate 3.1 to EN1004 when choosing the option "Factory mounting of valve manifolds", a separate certificate is provided for the transmitters and the valve manifolds respectively. Selection and Ordering data 7MF9011-4FA valve block on relative and absolute pressure transmitters Add -Z to the Order No. of the transmitter and add order codes. SITRANS P DSIII 7MF , 7MF and SITRANS P300 7MF With process connection female thread ½-14 NPT in-sealed with PTFE sealing strip Delivery incl. high-pressure test certified by factory certificate to EN MF9011-4EA valve block on relative and absolute pressure transmitters Add -Z to the Order No. of the transmitter and add order codes. SITRANS P DSIII 7MF , 7MF and SITRANS P300 7MF with process connection collar G1/ A to EN837-1 with gasket made of PTFE between valve manifold and transmitter Alternative sealing material: soft iron stainless steel, Mat. No copper Delivery incl. high-pressure test certified by factory certificate to EN Further designs: Delivery includes mounting brackets and mounting clips made of stainless steel (instead of the mounting bracket supplied with the transmitter) Supplied acceptance test certificate to EN for transmitters and mounted valve manifold Oil and grease-free cleaning for oxygen operation Order code T03 Order code T0 A70 A71 A7 A0 C1 E10 7MF9411-5BA valve manifold on absolute and differential pressure transmitters Add -Z to the Order No. of the transmitter and add order codes. SITRANS P DSIII 7MF433.-, 7MF443.- and 7MF ) Order code mounted with gaskets made of PTFE and screws made of chromized steel U01 stainless steel U0 Delivery incl. high-pressure test certified by factory certificate to EN MF9411-5CA valve manifold on differential pressure transmitters 1) Add -Z to the Order No. of the transmitter and add order codes. SITRANS P DSIII 7MF und 7MF ) mounted with gaskets made of PTFE and screws made of chromized steel stainless steel Delivery incl. high-pressure test certified by factory certificate to EN Further designs: Delivery includes mounting bracket and mounting clips made of steel stainless steel (instead of the mounting bracket supplied with the transmitter) Supplied acceptance test certificate to EN for transmitters and mounted valve manifold Oil and grease-free cleaning for oxygen operation Order code U03 U04 A01 A0 C1 E10 For 7MF transmitters, you require a 7/10-0 UNF connection thread in the process flange. /16 Siemens FI US Edition

127 Dimensional drawings Valve manifolds mounted on SITRANS P DS III Siemens AG 007 SITRANS P Accessories Factory-mounting of valve manifolds on SITRANS P transmitters Valve manifold 7MF9011-4EA with mounted relative pressure and absolute pressure transmitters Valve manifold 7MF9011-4EA with mounted relative pressure and absolute pressure transmitters, dimensions in mm (inch) Valve manifold 7MF9011-4FA with mounted relative pressure and absolute pressure transmitters Valve manifold 7MF9011-4FA with mounted relative pressure and absolute pressure transmitters, dimensions in mm (inch) Siemens FI US Edition /17

128 Siemens AG 007 SITRANS P Accessories Factory-mounting of valve manifolds on SITRANS P transmitters Valve manifold 7MF9411-5BA with mounted differential pressure transmitter Valve manifold 7MF9411-5CA with mounted differential pressure transmitter Valve manifold 7MF9411-5BA with mounted differential pressure transmitter, dimensions in mm (inch) Valve manifold 7MF9411-5CA with mounted differential pressure transmitter, dimensions in mm (inch) /18 Siemens FI US Edition

129 Valve manifolds mounted on SITRANS P300 Siemens AG 007 SITRANS P Accessories Factory-mounting of valve manifolds on SITRANS P transmitters Valve manifold 7MF9011-4EA with mounted relative pressure and absolute pressure transmitters Valve manifold 7MF9011-4EA with mounted relative pressure and absolute pressure transmitters, dimensions in mm (inch) Valve manifold 7MF9011-4FA with mounted relative pressure and absolute pressure transmitters Valve manifold 7MF9011-4FA with mounted relative pressure and absolute pressure transmitters, dimensions in mm Siemens FI US Edition /19

130 Transmitters for hydrostatic level MPS series (submersible sensor) Siemens AG 007 Overview Function SITRANS P pressure transmitters, MPS series, are for measuring the liquid levels in wells, tanks, channels and dams. Sensor Diaphragm p U const. U I EM + (brown) -1 (blue) I 0, U B SITRANS P pressure transmitters, MPS series (submersible sensor) SITRANS P pressure transmitters, MPS series, are submersible sensors for hydrostatic level measurements. The pressure transmitters of the MPS series are available for various measuring ranges and with explosion protection as an option. A junction box and a cable hanger are available as accessories for simple installation. Benefits Compact design Simple installation Small error in measurement (0.3%) Degree of protection IP68 Application SITRANS P pressure transmitters, MPS series, are used in the following branches for example: Oil and gas industries Shipbuilding Water supply SITRANS P pressure transmitters, MPS series, mode of operation and wiring diagram On one side of the sensor, the diaphragm is exposed to the hydrostatic pressure which is proportional to the submersion depth. This pressure is compared with atmospheric pressure. Pressure compensation is carried out using the vent pipe in the connection cable. The hydrostatic pressure of the liquid column acts on the sensor diaphragm, and transmits the pressure to the piezo-resistive bridge in the sensor. The output voltage of the sensor is applied to the electronic circuit where it is converted into an output current of 4 to 0 ma. The cable of the 7MF1570 transmitter must always be connected in the supplied junction box. The junction box has to be installed near the measuring point. If the medium is anything other than water, it is also necessary to check compatibility with the specified materials of the transmitter. Integration Vent pipe Screen Design SITRANS P pressure transmitters, MPS series, have a flushmounted piezo-resistive sensor with stainless steel diaphragm. These pressure transmitters are equipped with an electronic circuit fitted together with the sensor in a stainless steel housing. The cable also contains a strength cord and vent pipe. The diaphragm is protected against external influences by a protective cap. The sensor, electronic circuit and cable are sealed in a common housing of small dimensions. The pressure transmitter is temperature-compensated for a wide temperature range. Junction box 7MF1570-8AA, opened /130 Siemens FI US Edition

131 Siemens AG 007 Transmitters for hydrostatic level MPS series (submersible sensor) Measuring point setup, in principle Technical specifications SITRANS P pressure transmitters, MPS series (submersible sensor) Mode of operation Measuring principle Piezo-resistive Input Measured variable Hydrostatic level Measuring range Maximum working pressure 0... mh O ( fth O) 1.4 bar (0.3 psi) (corresponds to 14 mh O (4 fth O)) mh O ( fth O) 1.4 bar (0.3 psi) (corresponds to 14 mh O (4 fth O)) mh O ( fth O) 1.4 bar (0.3 psi) (corresponds to 14 mh O (4 fth O)) mh O ( fth O) 3.0 bar (43.5 psi) (corresponds to 30 mh O (90 fth O)) mh O ( fth O) 3.0 bar (43.5 psi) (corresponds to 30 mh O (90 fth O)) mh O ( fth O) 6.0 bar (87.0 psi) (corresponds to 60 mh O (180 fth O)) Output Output signal ma Accuracy To EN Error in measurement (including 0.3% of full-scale value (typical) non-linearity, hysteresis and repeatability, at 5 C (77 F)) Influence of ambient temperature Zero and span mh O ( fth O) 0.45%/10 K of full-scale value 6 mh O ( 18 fth O) 0.3%/10 K of full-scale value Long-term stability Zero and span mh O ( fth O) 6 mh O ( 18 fth O) Rated operating conditions Ambient conditions Process temperature Storage temperature Degree of protection to DIN EN 6059 Design Weight Pressure transmitters Cable Electrical connection Material Seal diaphragm Casing Gasket Connecting cable 0,5% of full-scale value/year 0.% of full-scale value/year C ( F) C ( F) IP kg ( 0.88 lb) 0.08 kg/m ( lb/ft) Cable with conductors with screen and vent pipe, strength cord (max. 300 N (67.44 lbf) Stainless steel, mat. No /316 Ti Stainless steel, mat. No /316 Ti Viton Optionally PE/HFFR sheath (non-halogen) or FEP sheath Power supply Terminal voltage on pressure transmitter (U B ) V DC Certificate and approvals The transmitter is not subject to the pressure equipment directive (DGRL 97/3/EC) Explosion protection Intrinsic safety "i" TÜV 03 ATEX 004X - Identification Ex II 1 G EEx ia IIC T4 Junction box Application Design Weight Electrical connection Cable entry Enclosure material Vent pipe for atmospheric pressure Screw for cable strength cord Rated operating conditions Degree of protection to DIN EN 6059 Cable hanger Application Design Weight Material For connecting the transmitter cable 0. kg (0.44 lb) x 3-way ( AWG) x M0x1.5 Polycarbonate IP54 For mounting the transmitter 0.16 kg (0.35 lb) Galvanized steel, polyamide Siemens FI US Edition /131

132 Transmitters for hydrostatic level MPS series (submersible sensor) Siemens AG 007 Selection and Ordering data SITRANS P pressure transmitters for pressure, MPS series (submersible sensor) Order No. C) 7 M F A wire system Note: Junction box and cable hanger included in delivery Cable material PE } 1 FEP 5 Measuring range Cable length L 0... mh O 10 m } C mh O 10 m } D mh O 5 m } B mh O 5 m } E mh O 5 m } F mh O 5 m } G fth O 3 ft K fth O 3 ft L fth O 8 ft M fth O 8 ft N fth O 8 ft P Special measuring range/special cable Z length 1) Specify measuring range and cable length in plain text Explosion protection without } 1 with, type of protection "Intrinsic safe-ty" (Ex II 1 G EEx ia IIC T4) With approval for drinking water to 6 WRAS and ACS Further designs Order code Manufacturer's test certificate M to DIN C , Part 18 and ISO 840 (calibration certificate),add "-Z" to Order No. and Order code. Order No. Manufacturer's test certificate M to DIN 7MF1564-8CC , Part 18 and ISO 840 (calibration certificate) supplied later, specify factory no. of transmitter for this porpose. Accessories (as spare parts) Junction box 7MF1570-8AA for connecting the transmitter cable J 1 Y Dimensional drawings SITRANS P pressure transmitters, MPS series, dimensions in mm (inch) 79 (3.1) Protective cap Ø 7 (1.1 diam.) 158 (6.) L 50 (1.97) 65 (.56) Junction box, dimensions in mm (inch) + (brown) Vent pipe - (blue) Screen Cable sheath 8.3 (0.33) diam. (black or blue, PE/HFFR) Flexible cable with 0.5 mm ( inch ) cross-section Vent pipe 1 (0.04) diam. (inner diameter) Protective cap with 4 x 3 diam. (4 x 0.1 diam.) holes (black, PA) M0x1.5 M0x1.5 Mounting hole Venting valve Cable sheath 57 (.5) (0.87) (0.87) Strength cord (white) 30 (1.) 94 (3.7) 30 (1.) Cable hanger for mounting the pressure transmitter 7MF1570-8AB } Available ex stock Power supply units see "SITRANS I power supply units and input isolators". 1) Special measuring ranges between mh O ( fth O) and mh O ( fth O) and special cable lengths up to 00 m (600 ft) are possible. With Ex versions the max. special cable length is 50 m (150 ft). C) Subject to export regulations AL: N, ECCN: EAR99. Cable hanger, dimensions in mm (inch) /13 Siemens FI US Edition

133 Siemens AG 007 Remote seals for transmitters and pressure gauges Introduction Application The remote seals 7MF48.. can be fitted to SITRANS P transmitters for pressure (7MF4033 and 7MF4034), absolute pressure (7MF433, 7MF434, 7MF4333, 7MF4334) and differential pressure and flow (7MF4433 and 7MF4434). Design and mode of operation A remote seal system consists of a transmitter, one or two remote seals, an appropriate transmission liquid, and a connection between the transmitter and remote seal (direct mounting or capillary). The volume in contact with the measured medium is defined by an elastic diaphragm. The volume between this diaphragm and the pressure transmitter is completely filled with a transmission liquid. If a pressure is now applied to the remote seal, this is transmitted via the elastic diaphragm and the filling liquid to the pressure transmitter. In many cases, a capillary is located between the remote seal and the pressure transmitter in order e.g. to minimize temperature effects from the hot medium on the latter. However, the capillary line influences the response time and the temperature response of the complete remote seal system. When fitting remote seals to differential pressure transmitters, two capillaries of the same length must always be used. Fields of use Remote seal systems should be used if a separation between the measured medium and the measuring instrument is appropriate or essential for the following reasons: The temperature of the medium is outside the limits specified for the transmitter. The medium is corrosive and requires diaphragm materials in the transmitter which are not available. The medium is highly viscous or contains solids which would block the measuring chambers of the transmitter. The medium may freeze in the measuring chambers or pulse line. The medium is heterogeneous and fibrous. The medium tends towards polymerization or crystallization. The process requires quick-release remote seals, as necessary e.g. in the food industry for fast cleaning. The process requires cleaning of the measuring point, e.g. in a batch process. Constructional designs A differentiation is made between diaphragm seals and inline seals. With the diaphragm seals, the pressure is measured via a flat convoluted diaphragm which rests in a backup bed. With the inline seals, the pressure is measured via a cylindrical diaphragm positioned in a pipe, and transmitted to the transmitter via the filling liquid. The inline seal is a special design for flowing media. It consists of a cylindrical pipe in which a cylindrical diaphragm is embedded. Since it is completely integrated in the process pipe, no turbulences, dead volumes or other obstructions to the flow occur. The inline seal can furthermore be cleaned by a pig-tail. Diaphragm seal of pancake design, and also with extended diaphragm (extension) Diaphragm seal of flush flange design, and also with extended diaphragm (extension) Tri-Clamp sanitary remote seal Diaphragm seals The following types of diaphragm seals exist: Pancake design, and pancake design with extended diaphragm (extension) to DIN or ANSI which are secured using a backup blind flange. Flush flange design, and flange design with extended diaphragm (extension) to DIN or ANSI which are installed by using holes in the flange. Sanitary remote seals, e.g. to DIN 11851, Cherry Burrell, APC connection, Tri-clamp connection, etc.. The sanitary remote seals are common designs in the food industry. Their design means that the measured medium cannot accumulate in dead volumes. The sanitary clamp present on the remote seal means that quick dismounting is possible for cleaning. Button diaphragm seal with male thread for screwing into tapped holes. Remote seals with customer-specific process connections. Siemens FI US Edition /133

134 Remote seals for transmitters and pressure gauges Introduction Siemens AG 007 Clamp-on seals The following types of clamp-on seals exist: Sanitary inline seals, e.g. to DIN 11851, Cherry Burrell, triclamp connection etc. The sanitary facility enables the seal to be removed quickly for cleaning purposes. Inline seals for positioning between DIN or ANSI flanges. Inline seals with customer-specific process connections. Transmission response Temperature errors occur if the filling liquid in the remote seal Button diaphragm seal with diaphragm flush with front and in the capillaries expands or contracts as a result of temperature effects. The temperature error depends on the diaphragm charateristic, the influence of the filling liquid, and the influence of the filling liquid under the process flanges or in the flanges on the transmitter (volume minimized for remote seals). Diaphragm characteristic The charateristic of the remote seal is of decisive importance. The larger the diaphragm diameter, the softer it is. In comparison to a smaller diaphragm, this means that it can respond far easier to temperature-based expansions of the filling liquid. The result is that small measuring ranges are only possible with large diaphragm diameters. In addition, the diaphragm thickness, its material, and any coatings which may be present must be considered. Sanitary tri-clamp seal and for flange sandwich mounting Filling liquid All filling liquids expand or contract when the temperature varies. Temperature-independent errors can be minimized by selecting a suitable filling liquid, but it must also be ensured that ity and the lowest coefficient of expansion, and which simulta- A filling liquid should be selected which has the lowest viscos- the filling liquid is appropriate for the temperature limits and operating pressure. For food and beverage as well as pharmaceusure/vacuum and temperature. The filling liquid must also be neously fulfills the process requirements with respect to prestical applications see reference for FDA approved fill fluids. compatible with the process medium. When installing the equipment for vacuum applications, the Since the filling liquid is present under the remote seal diaphragm, in the capillaries and under the process flanges of the transmitter must always be located below the lowest tap. transmitter, the temperature error must be calculated separately It should also be noted that some of the filling liquids are very for each combination. limited with respect to the permissible temperature of the medium for vacuum applications. Response time When operating permanently at a vacuum, the remote seal The response time depends on the internal diameter of the capillaries, the viscosity of the filling liquid, the capillary extension must be designed in the version resistant to those vacuum applicaton. length, and the pressure in the measuring system: Recommendations on the minimum span can be found in the Internal diameter: tables on pages /135 and /136. The response time decreases as the internal diameter increases, but the temperature error increases. Note Viscosity: The response time increases as the viscosity increases. The remote seals listed in this catalog are a selection of the most common designs. As a result of the large variety of process connections, it may nevertheless be the case that certain remote Capillary length: The capillary length has a proportional effect on the response seals which are not listed in the catalog are still available. time and the temperature error. Other versions could be: Measuring system pressure: Other process connections, standards The response time decreases as the pressure in the measuring Aseptic or sterile connections system increases. Other dimensions Other nominal pressures Special diaphragm materials, including coatings Other sealing faces Other filling liquids Other capillary lengths Sheathing of capillaries with protective hose Calibration at higher/lower temperatures etc. Recommendations The following should be observed to obtain an optimum combination of transmitter and remote seal: The remote seal diameter, and thus the effective diameter of the diaphragm, should be selected as large as possible in order to keep the temperature-dependence errors as low as possible. The capillaries should be selected as short as possible in order to keep the response time and the temperature-dependent errors as low as possible. Please contact your Siemens Regional Office for more information. /134 Siemens FI US Edition

135 Siemens AG 007 Remote seals for transmitters and pressure gauges Introduction Technical data Nominal diameter, nominal pressure, pressure connection Sealing face (only for pancake and flanged remote seals) Materials Main body for pancake and flange remote seals Wetted parts materials Housing and diaphragm for Inline seals Capillary Armor See Ordering data To ANSI B16.5 RF 50 RMS for stainless steel or solid materials or ANSI B16.5 RFSF (smooth finish) for other materials Stainless steel, mat. No /316L See Ordering data Stainless steel, mat. No / 316L or stainless steel, 7MF and 7MF Stainless steel, mat. No /316Ti Spiral hose made of stainless steel, mat. No. 304 Sealing material in the transmitter pressure flanges For absolute pressure transmitters and vacuum applications For other applications Max. pressure Capillary Length Internal bore Smallest bending radius Filling liquid For pancake and flange remote seals For sanitary remote seals Ambient temperature Certificates and approvals Classification according to pressure equipment directive (DGRL 97/3/EC) Copper Viton See nominal pressure of remote seal and transmitter Max. 30 ft. longer lengths on inquiry inch 6.0 inch See Ordering data Neobee M0 or glycerine/water See transmitter and filling liquid For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of article 3, paragraph 3 (sound engineering practice) Measuring errors based on physical properties always result when using remote seals Temperature errors of diaphragm seals when connected to pressure, absolute pressure or level transmitters, and with single-sided connection to differential pressure transmitters Flange to ANSI B16.5 Flange to DIN 501 Sanitary Tri-Clamp Button Seal Nominal diameter/ design " flush flanged " with extension 3" flush flanged 3" with extension 4" flush flanged 4" with extension 5" flush flanged 5" with extension DN 50 flush flanged DN 50 with extension DN 80 flush flanged DN 80 with extension DN 100 flush flanged DN 100 with extension DN 15 flush flanged DN 15 with extension 1 ½" " ½" 3" 4" 1 NPT-male 1 ½ NPT-male " NPT-male Effective diaphragm diameter [in] Temperature error of remote seal [inh O/5 F] Temperature error of capillary [inh O/5 F/3 ft] Temperature error of transmitter flange connection [inh O/5 F] Recommended values, min. spans (observe temperature error) [psi] Temperature errors of diaphragm seals (part 1) Remarks: Values apply to liquids: silicone oil DC 00, high-temperature oil, halocarbon oil and Neobee M0. Half the values apply to glycerine/water mixture as the filling liquid. Values apply to stainless steel as the diaphragm material. Siemens FI US Edition /135

136 Remote seals for transmitters and pressure gauges Introduction Siemens AG 007 Temperature errors of diaphragm seals with double-sided connection to differential pressure transmitters Flange to ANSI B16.5 Flange to DIN 501 Sanitary Tri-Clamp Nominal diameter/ design " flush flanged " with extension 3" flush flanged 3" with extension 4" flush flanged 4" with extension 5" flush flanged 5" with extension DN 50 flush flanged DN 50 with extension DN 80 flush flanged DN 80 with extension DN 100 flush flanged DN 100 with extension DN 15 flush flanged DN 15 with extension " ½" 3" 4" Effective diaphragm diameter [in] Temperature error of remote seal [inh O/5 F] Temperature error of capillary [inh O/5 F/3 ft] Temperature error of transmitter flange connection [inh O/5 F] Recommended values, min. spans (observe temperature error) [psi] Temperature errors of diaphragm seals (part ) Remarks: Values apply to liquids: silicone oil DC 00, high-temperature oil, halocarbon oil and Neobee M0. Half the values apply to glycerine/water mixture as the filling liquid. Values apply to stainless steel as the diaphragm material. Temperature errors of clamp-on seals when connected to pressure or absolute pressure transmitters, and with single-sided connection to differential pressure transmitters Nominal diameter/ design Temperature error of remote seal [inh O/5 F] Temperature error of capillary [inh O/5 F/3 ft] Temperature error of transmitter flange connection [inh O/5 F] Recommended values, min. spans (observe temperature error) [psi] 1 inch 1 ½ inch inch 3 inch 4 inch Temperature errors of clamp-on seals with double-sided connection to differential pressure transmitters Nominal diameter/ design Temperature error of remote seal [inh O/5 F] Temperature error of capillary [inh O/5 F/3 ft] Temperature error of transmitter flange connection [inh O/5 F] Recommended values, min. spans (observe temperature error) [psi] 1 inch 1 ½ inch inch 3 inch 4 inch Temperature errors of clamp-on seals Remarks: Values apply to liquids: silicone oil DC 00, high-temperature oil, halocarbon oil and Neobee M0. Half the values apply to glycerine/water mixture as the filling liquid. Values apply to stainless steel as the diaphragm material. Diaphragm thickness: 1" & 1 ½" & ":0.00 inch 3" & 4": inch /136 Siemens FI US Edition

137 Siemens AG 007 Remote seals for transmitters and pressure gauges Introduction Calculation of temperature error for remote seals The following equation is used to calculate the temperature error for remote seals: dp = (t RS - t Cal ). f RS + (t Cap - t Cal ). l Cap. f Cap + (t TR - t Cal ). f PF dp Additional temperature error (inh O) t RS Temperature on remote seal diaphragm (generally corresponds to temperature of medium) t Cal Reference (calibration) temperature 68 F f RS Temperature error of remote seal (see tables on pages /135 and /136) t Cap Ambient temperature on the capillaries l Cap Capillary extension length (error given per 3 ft) f Cap Temperature error of capillaries (see tables on pages /135 and /136) t TR Ambient temperature on transmitter f PF Temperature error of oil filling in process flanges of transmitter (see tables on pages /135 and /136) Example of calculation of temperature error for remote seals Existing conditions: SITRANS P transmitter for differential f RS = inh O/5 F pressure, 100 inh O, set to 0 to 40 inh O with 3 in flush flanged remote seal, diaphragm made of stainless steel, mat. No /316L Capillary x 15 ft l Cap = x 15 ft Capillaries fitted on both sides f Cap = 0.04 inh O/5 F/3 ft Filled with silicone oil DC f PF = 0.04 inh O/5 F Temperature of medium 1 F t RS = 1 F Temperature on capillaries 1 F t Cap = 1 F Temperature on transmitter 1 F t TR = 1 F Required: Additional temperature error dp of remote seal Dependence of temperature error on diaphragm material The errors listed in the tables on pages /135 and /136 refer to the use of stainless steel as the diaphragm material. If a different material is used, the listed values change by the amount shown in the following table. Diaphragm material Change in temperature error of remote seal Stainless steel Values as specified in tables on pages /135 and /136 Hastelloy C4, mat. No Increase in values by 50% Hastelloy C76, mat. No Increase in values by 50% Monel 400, mat. No Increase in values by 60% Tantalum Increase in values by 50% Titanium Increase in values by 50% Teflon lining on stainless steel Increase in values by 10% diaphragm Halar coating or PFA coating on Increase in values by 100% stainless steel diaphragm Gold coating on stainless steel Increase in values by 40% diaphragm Response times (guidance values) The listed values are the response times (in seconds, per meter of capillary extension) for a change in pressure which corresponds to the set span. The listed values must be multiplied by the respective length of the capillary extension, or with transmitters for differential pressure and flow by the total length of both capillary extensions. The response times are independent of the set span within the range of the respective transmitter. The response times are of insignificant importance for spans above 145 psi (10 bar). The response times of the transmitters have not been considered. Calculation: (dp = (1 F 68 F) inh Oi/5 F + (1 F 68 F) 15 ft 0.04 inh O/5 F / 3ft + (1 F 68 F) 0.04 inh O/5 F) (dp = inh O inh O inh O) Result: dp = 1.44 inh O (corresponds to % of set span) Note: The temperature error determined above only applies to the error resulting from connection of the remote seal. The transmission response of the respective transmitter is not included in this consideration. It must be calculated separately, and the resulting error added to the error determined above from connection of the remote seal. Siemens FI US Edition /137

138 Remote seals for transmitters and pressure gauges Introduction Siemens AG 007 Filling liquid Density Temperature on capillary Response time in s/m (s/ft) with max. span of transmitter kg/dm 3 (lb/in 3 ) C ( F) 50 mbar (3.63 psi) 600 mbar (8.7 psi) 1600 mbar (3. psi) Silicone oil DC Silicone oil DC (0.033) (0.035) Syltherm (0.034) High-temperature oil 1.07 (0.039) Halocarbon oil (0.071) Fluorolube (0.068) Neobee M (0.033) Glycerine/water 1. (0.044) (140) (68) (-4) (140) (68) (-4) (140) (68) (-4) (140) (68) (14) (140) (68) (68) (140) (68) (68) (140) (68) (68) (140) (68) (3) (0.018) (0.034) (0.091) (0.183) (0.186) (0.515) (0.018) (0.034) (0.091) (0.043) (0.198) (1.07) (0.01) (0.088) (0.878) (0.01) (0.088) (0.878) (0.055) (0.131) (0.363) (0.040) (0.3) (.963) (0.006) (0.006) (0.037) (0.076) (0.079) (0.16) (0.006) (0.006) (0.37) (0.018) (0.08) (0.503) (0.009) (0.037) (0.366) (0.009) (0.037) (0.366) (0.04) (0.055) (0.15) (0.015) (0.098) (1.34) (0.003) (0.006) (0.015) (0.07) (0.030) (0.08) (0.003) (0.006) (0.015) (0.006) (0.030) (0.189) (0.003) (0.015) (0.137) (0.003) (0.015) (0.137) (0.009) (0.01) (0.055) (0.006) (0.037) (0.460) Technical data of filling liquid When selecting the filling liquid, check that it is suitable with respect to the permissible temperature of the medium and the process pressure. Also check the compatibility with the measured medium. For example, only food grade filling liquids may be used in the food industry. A special case are oxygen and chlorine as the measured media; the filling liquid must not react with them, otherwise an explosion or fire may occur if there is a leak in the remote seal. Filling liquid Permissible temperature of medium Density at 0 C (68 F) Silicone oil DC00-10 Silicone oil DC Viscosity at 0 C (68 F) Expansion coefficient p abs <1 bar (p abs <14.5 psi) p abs >1 bar (p abs >14.5 psi) kg/dm 3 (lb/in 3 ) m /s 10 6 (ft /s 10 6 ) 1/ C (1/ F) C ( F) C ( F) -40 to +11 (-40 to +48) -40 to +00 (-40 to +39) (0.03) 10 (107.6) ( ) -0 to +150 (-4 to +30) -0 to +50 (-4 to +48) 0.96 (0.03) 50 (538) ( ) Syltherm to +11 (-40 to +50) -40 to +05 (-40 to +400) (0.034) (107.9) ( ) High-temperature -10 to +00 (+14 to +39) -10 to +350 (+14 to +66) 1.07 (0.04) 39 (40) ( ) oil Halocarbon oil -40 to +80 (-40 to +176) -40 to +175 (-40 to +347) (0.07) 14 (151) ( ) Fluorolube Not possible Not possible -40 to +175 (-40 to +347) (0.068) 15.5 (167) ( ) Neobee M0 10 to +90 (+14 to +195) -10 to +00 (+14 to +39) (0.03) 9.8 (105) ( ) Glycerine/water Not possible Not possible -10 to +10 (+14 to +48) 1. (0.04) 88 (947) (0.0008) Maximum temperature of medium The following maximum temperatures of the medium apply depending on the wetted parts materials: 0 Material p abs < 1 bar (14.5 psi) p abs > 1 bar (14.5 psi) C ( F) C ( F) Stainless steel, mat. No /316Ti 00 (39) 350 (66) PTFE coating 100 (1) 150 (30) ECTFE/PFA coating 100 (1) 150 (30) Hastelloy C4, mat. No (39) 350 (66) Hastelloy C76, mat. No (39) 350 (66) Monel 400, mat. No (39) 350 (66) Tantalum 00 (39) 300 (57) Maximum capillary length (guidance values for diaphragm seals and inline seals) Nominal diameter Max. length of capillary Diaphragm seal Inline seal DN 5 (1 inch).5 m (8. ft).5 m (8. ft) DN 3 (1¼ inch).5 m (4.9 ft).5 m (8. ft) DN 40 (1½ inch) 4 m (13.1 ft) 6 m (19.7 ft) DN 50 ( inch) 6 m (19.7 ft) 10 m (3.8 ft) DN 65 (½ inch) 8 m (6. ft) 10 m (3.8 ft) DN 80 (3 inch) 10 m (3.8 ft) 10 m (3.8 ft) Size 4 inch (30.0 ft) Size 5 inch (30.0 ft) /138 Siemens FI US Edition

139 Pancake type diahragm seal Dimensions (Connection to ASME B16.5) Size Class D DM F A [in ] " 3" " " Size = Nominal pipe size DM = Effective diaphragm diameter Class = Flange rating per ASME B16.5 All dimensions in inches unless otherwise noted Pancake type diaphragm seal, dimensions Remote seals for transmitters and pressure gauges Pancake type diaphragm seal with flexible capillary tube Siemens AG 007 Selection and Ordering data Order No. Order code Pancake type diaphragm seal with flexible capillary extension, connected to a SITRANS P transmitter (order separately) for pressure 7MF or 7MF4 7 7 C) 7 M F for absolute pressure 7MF C) 7 M F for differential pressure 7MF C) 7 M F B Size and class inch 3 inch 4 inch 5 inch class class class class Special design, customer information to be supplied Materials and wetted parts SST 316L SST 316L with carbon pigmented Teflon lined diaphragm (good upto 500 F) Monel 400, mat. No Hastelloy C76, mat. No Tantal Special design, customer information to be supplied Extension length C) Subject to export regulations AL: N, ECCN: EAR99. E H L N Z A E 0 G J K Z J 1 Y K 1 J Without extension (standard version) 0 Special design, customer information to be 9 L 1 Y supplied System fill Silicone oil DC Silicone oil DC High temperature oil Halocarbon (for O -application) Silicone oil M5 Syltherm 800 DC704 silicone oil Fluorolube Special design, customer inform. to be supplied 9 M 1 Y Length of capillary 3 ft 5 ft 10 ft 15 ft 0 ft 5 ft 30 ft Special design, customer inform. to be supplied 9 N 1 Y Further designs Please add -Z to Order No. and specifiy Order code for 7MF4800 Integrated flame path restriction A 0 1 Certificate of calibration N.I.S.T. (0% steps) C 1 1 Material conformance certificate C 1 Vacuum service (must be specified with HT oil) V 0 1 Calculation of span of transmitter (completed Y 0 5 questionnaire to be attached) for 7MF4801 Integrated flame path restriction A 0 1 Certificate of calibration N.I.S.T. (0% steps) C 1 1 Material conformance certificate C 1 Calculation of span of transmitter (completed Y 0 5 questionnaire to be attached) for 7MF4803 Integrated flame path restriction A 0 Certificate of calibration N.I.S.T. (0% steps) C 1 1 Material conformance certificate C 1 Vacuum service (must be specified with HT oil) V 0 3 Calculation of span of transmitter (completed questionnaire to be attached) Y 0 5 Siemens FI US Edition /139

140 Siemens AG 007 Remote seals for transmitters and pressure gauges Flange-type diaphragm seal directly connected Flange-type diaphragm seal, without extension Dimensions (connection to ASME B16.5) Optional instrument Welded capillary connection 1/4 NPT 1/ NPT Flange-type diaphragm seal without extension for flanges 1" Optional instrument connections welded capillary connection 1/4 NPT 1/ NPT Size Class A B C DM E F G X Weight DN lbs ½" ¾" " " " " " DN = Nominal pipe size DM = Effective diaphragm diameter Class = Flange rating per ASME B16.5 X = Number of bolt holes All dimensions in inches unless otherwise noted Flange-type diaphragm seal, without extension, dimensions Flange-type diaphragm seal without extension for flanges 1.5" /140 Siemens FI US Edition

141 Flange-type diaphragm seal, with extension Dimensions Size Class A B C DM E 1) F G H X L DN " " Flange-type diaphragm seal, with extension, dimensions Remote seals for transmitters and pressure gauges Flange-type diaphragm seal directly connected " ) based on schedule 40 DN = Nominal pipe size DM = Effective diaphragm diameter Class = Flange rating per ASME B16.5 X = Number of bolt holes All dimensions in inches unless otherwise noted Instrument connection Options Welded capillary connection 1/4 NPT 1/ NPT Siemens AG 007 Selection and Ordering data Order No. Order code Flange-type diaphragm seal directly connected to a SITRANS P 7MF or 7MF4 7 7 (order separately) C) 7 M F Process connection vertical (transmitter upright) horizontal Size and class inch inch inch inch 3 inch 3 inch 3 inch 4 inch 4 inch 4 inch class 150 class 300 class 600 class 1500 class 150 class 300 class 600 class 150 class 300 class 400 Special design, customer information to be supplied Materials and wetted parts SST 316L SST 316L with carbon pigmented Teflon lined diaphragm (good upto 500 F) Monel 400, mat. No Hastelloy C76, mat. No Tantal Special design, customer information to be supplied Extension length Without extension (standard version) " 4" 6" 8" Special design, customer information to be supplied System fill Silicone oil DC Silicone oil DC High temperature oil Halocarbon (for O -application) Silicone oil M5 Syltherm 800 DC704 silicone oil Fluorolube Special design, customer information to be supplied Further designs Please add -Z to Order No. and specifiy Order code Integrated flame path restriction Rotatable Flange Certification of calibration N.I.S.T. (0% steps) Material conformance certificate Vacuum service (must be specified with HT oil) Calculation of span of transmitter (completed questionnaire to be attached) C) Subject to export regulations AL: N, ECCN: EAR99. 0 L M N P Q R S T U V Z A E 0 G J K Z J 1 Y K 1 Y L 1 Y M 1 Y A 0 1 B 0 1 C 1 1 C 1 V 0 1 Y 0 5 Siemens FI US Edition /141

142 Remote seals for transmitters and pressure gauges Flange-type diaphragm seal directly connected Selection and Ordering data Order No. Order code Mounting flange directly mounted at SITRANS P for Level 7MF (order separately) C) 7 M F Flange Size Class ANSI B16.5 inch L M 3 inch 150 Q 300 R 4 inch 150 T 300 U Special design, customer information to be supplied Z J 1 Y Materials and wetted parts SST 316L SST 316L with carbon pigmented Teflon lined diaphragm (good upto 500 F) Monel 400, mat. No Hastelloy C76, mat. No Tantal Special design, customer information to be supplied Extension length Without extension (standard version, 0 mm) " 50 mm 4" 100 mm 6" 150 mm 8" 00 mm Special design, customer information to be supplied System fill Silicone oil DC Silicone oil DC High temperature oil Halocarbon (for O -application) Silicone oil M5 Syltherm 800 DC704 silicone oil Fluorolube Special design, customer information to be supplied Further designs Please add -Z to Order No. and specifiy Order code Integrated flame path restriction Rotatable Flange Certificates: Certification of calibration N.I.S.T. (0% steps) Material conformance certificate Vacuum service (must be specified with HT oil) Calculation of span of transmitter (completed questionnaire to be attached) C) Subject to export regulations AL: N, ECCN: EAR99. A E 0 G J K Z K 1 Y L 1 Y M 1 Y Siemens AG 007 A 0 1 B 0 1 C 1 1 C 1 V 0 4 Y 0 5 Selection and Ordering data Order No. Order code Mounting flange at High-Side, Flange-Type Seal, w/o extension Flange-type seal via capillary extension on low-side without extension for SITRANS P for differential pressure 7MF (order separately) C) 7 M F B Flange Size Class ANSI B16.5 inch L M 3 inch 150 Q 300 R 4 inch 150 T 300 U Special design, customer information to be supplied Z J 1 Y Materials and wetted parts SST 316L SST 316L with carbon pigmented Teflon lined diaphragm (good upto 500 F) Monel 400, mat. No Hastelloy C76, mat. No Tantal Special design, customer information to be supplied Extension length Without extension (standard version, 0 mm) " 50 mm 4" 100 mm 6" 150 mm 8" 00 mm Special design, customer information to be supplied System fill Silicone oil DC Silicone oil DC High temperature oil Halocarbon (for O -application) Silicone oil M5 Syltherm 800 DC704 silicone oil Fluorolube Special design, customer information to be supplied Capillary length at low-side 3 ft 5 ft 10 ft 15 ft 0 ft 5 ft 30 ft Special design, customer information to be supplied Further designs Please add -Z to Order No. and specifiy Order code Integrated flame path restriction Rotatable Flange Certification of calibration N.I.S.T. (0% steps) Material conformance certificate Vacuum service (must be specified with HT oil) Calculation of span of transmitter (completed questionnaire to be attached) A E G J K Z K 1 Y L 1 Y M 1 Y A 0 B 0 1 C 1 1 C 1 V 0 4 Y 0 5 C) Subject to export regulations AL: N, ECCN: EAR99. /14 Siemens FI US Edition

143 Siemens AG 007 Remote seals for transmitters and pressure gauges Diaphragm seal "flanged off-line low-pressure type", directly connected DM = Effective diaphragm diameter G1 = Instrument connection G = Process connection G3 = Threaded bolt hole X = Number of bolt holes Class = Flange rating per ASME B16.5 Size = Nominal pipe size All dimensions in inches unless otherwise noted Diaphragm seal "flanges off-line low-pressure type" Dimensions (Connection to ASME B16.5) Size Instrument connection options welded capillary connection 1/4 NPT 1/ NPT G Class ½" 150# ½"-13UNC G3 X A B C DM E ½" 300# ½"-13UNC ½" 600# ½"-13UNC ¾" 150# ½"-13UNC ¾" 300# 5 / 8 "-11UNC ¾" 600# 5 / 8 "-11UNC " 150# ½"-13UNC " 300# 5 / 8 "-11UNC " 600# 5 / 8 "-11UNC ½" 150# ½"-13UNC ½" 300# ¾"-10UNC ½" 600# ¾"-10UNC " 150# 5 / 8 "-11UNC " 300# 5 / 8 "-11UNC " 600# 5 / 8 "-11UNC Selection and Ordering data Order No. Order code Diaphragm seal "flanged off-line low-pressure type" direct mount to transmitter, 316 stainless steel C) 7 M F upper housing SITRANS P for 7MF or 7MF (order separately) Size and class ½ inch class 150#RF ½ inch class 300#RF ½ inch class 600#RF ¾ inch class 150#RF ¾ inch class 300#RF ¾ inch class 600#RF 1 inch class 150#RF 1 inch class 300#RF 1 inch class 600#RF 1 ½ inch class 150#RF 1 ½ inch class 300#RF 1 ½ inch class 600#RF inch class 150#RF inch class 300#RF inch class 600#RF Special design, customer information to be supplied Materials and wetted parts SST 316L SST 316L with carbon pigmented Teflon lined diaphragm (good upto 500 F) Monel 400, mat. No Hastelloy C76, mat. No Tantal Special design, customer information to be supplied Flushing port(s) None 1 x ¼"NPT-female (available w/ SS, HC or MO) x ¼"NPT-female (available w/ SS, HC or MO) Special design, customer information to be supplied System fill Silicone oil DC Silicone oil DC High temperature oil Halocarbon (for O -application) Silicone oil M5 Syltherm 800 DC704 silicone oil Fluorolube Special design, customer information to be supplied Further designs Please add -Z to Order No. and specifiy Order code C) Subject to export regulations AL: N, ECCN: EAR99. A B C E F G J K L N P Q S T U Z A E G J K Z J 1 Y K 1 Y L 1 Y M 1 Y Integrated flame path restriction A 0 1 Certification of calibration N.I.S.T. (0 % steps) C 1 1 Material conformance certificate C 1 Vacuum service (must be specified with HT oil) V 0 1 Calculation of span of transmitter (completed Y 0 5 questionnaire to be attached) Siemens FI US Edition /143

144 Siemens AG 007 Remote seals for transmitters and pressure gauges Flange-type diaphragm seal with flexible capillary tube Flange-type diaphragm seal with flexible capillary extension Dimensions (Connection to ASME B16.5) Flange-type diaphragm seal for flanges 1" System fill port Optional instrument Welded capillary connection 1/4 NPT 1/ NPT Optional instrument connections welded capillary connection 1/4 NPT 1/ NPT Connection to ASME B16.5 Size Class A B C DM E F G X Weight DN lbs ½" ¾" " " " " " DN = Nominal pipe size DM = Effective diaphragm diameter Class = Flange rating per ASME B16.5 X = Number of bolt holes All dimensions in inches unless otherwise noted Flange-type diaphragm seal for flanges 1.5" /144 Siemens FI US Edition

145 Selection and Ordering data Order No. Order code Flange-type diaphragm seal with flexible capillary extension, connected to a SITRANS P transmitter (order separately) for pressure 7MF or 7MF4 7 7 C) 7 M F for absolute pressure 7MF C) 7 M F for differential pressure 7MF C) 7 M F B Size and class inch inch inch inch 3 inch 3 inch 3 inch 4 inch 4 inch 4 inch 5 inch 5 inch 5 inch class 150 class 300 class 600 class 1500 class 150 class 300 class 600 class 150 class 300 class 400 class 150 class 300 class 400 Special design, customer information to be supplied Materials and wetted parts SST 316L SST 316L with carbon pigmented Teflon lined diaphragm (good upto 500 F) Monel 400, mat. No Hastelloy C76, mat. No Tantal Special design, customer information to be supplied Extension length Remote seals for transmitters and pressure gauges Flange-type diaphragm seal with flexible capillary tube L M N P Q R S T U V W X Y Z A E 0 G J K Z J 1 Y K 1 Y Without extension (standard version) 0 Special design, customer information to be 9 L 1 Y supplied System fill Silicone oil DC Silicone oil DC High temperature oil Halocarbon (for O -application) Silicone oil M5 Syltherm 800 DC704 silicone oil Fluorolube Special design, customer information to be supplied Length of capillary 3 ft 5 ft 10 ft 15 ft 0 ft 5 ft 30 ft Special design, customer information to be supplied M 1 Y Siemens AG N 1 Y Selection and Ordering data Order code Further designs Please add -Z to Order No. and specifiy Order code for 7MF480 Integrated flame path restriction A 0 1 Rotatable Flange B 0 1 DP "H" flange service B 0 Certificate of calibration N.I.S.T. (0% steps) C 1 1 Material conformance certificate C 1 Vacuum service (must be specified with HT oil) V 0 1 Calculation of span of transmitter (completed Y 0 5 questionnaire to be attached) for 7MF481 Integrated flame path restriction A 0 1 Rotatable Flange B 0 1 Certificate of calibration N.I.S.T. (0% steps) C 1 1 Material conformance certificate C 1 Calculation of span of transmitter (completed Y 0 5 questionnaire to be attached) for 7MF483 Integrated flame path restriction A 0 Rotatable Flange B 0 1 Certificate of calibration N.I.S.T. (0% steps) C 1 1 Material conformance certificate C 1 Vacuum service (must be specified with HT oil) V 0 3 Calculation of span of transmitter (completed questionnaire to be attached) Y 0 5 C) Subject to export regulations AL: N, ECCN: EAR99. Siemens FI US Edition /145

146 Remote seals for transmitters and pressure gauges Diaphragm seal "flanged off-line type" Siemens AG 007 G1 G G3 A B C DM E ½" 150# 4 x ½"-13UNC ½" 300# 4 x ½"-13UNC ½" 600# 4 x ½"-13UNC " 150# 4 x ½"-13UNC " 300# 4 x 5 / 8 "-11UNC ¼"-NPT 1" 600# 4 x 5 / 8 "-11UNC or ½"-NPT 1 ½" 150# 4 x ½"-13UNC ½" 300# 4 x ¾"-10UNC ½" 600# 4 x ¾"-10UNC " 150# 4 x 5 / 8 "-11UNC " 300# 8 x " 600# 8 x Diaphragm seal "flanged off-line type" Dimensions (Connection to ASME B16.5) System fill port Instrument connection G1 G G3 F H J Weight lbs ½" 150# 4 x ½"-13UNC ½" 300# 4 x ½"-13UNC ½" 600# 4 x ½"-13UNC ¼"-NPT or ½"-NPT 1" 150# 4 x ½"-13UNC " 300# 4 x 5 / 8 "-11UNC " 600# 4 x 5 / 8 "-11UNC ½" 150# 4 x ½"-13UNC ½" 300# 4 x ¾"-10UNC ½" 600# 4 x ¾"-10UNC " 150# 4 x 5 / 8 "-11UNC " 300# 8 x " 600# 8 x Instrument connection DM = Effective diaphragm diameter G1 = Instrument connection G = Process connection G3 = Threaded bolt hole All dimensions in inches unless otherwise noted Diaphragm seal "flanged off-line type", dimensions System fill port Optional 1/8 NPT or 1/4 NPT flushing connection /146 Siemens FI US Edition

147 Siemens AG 007 Remote seals for transmitters and pressure gauges Diaphragm seal "flanged off-line type" Selection and Ordering data Order No. Order code Diaphragm seal "flanged off-line type" MWP depends on flange with flexible armored capillary, 316 stainless C) 7 M F steel upper housing SITRANS P for 7MF and 7MF4 7 7 (order separately) B 777 Seal design Stud mount All-welded stud mount Through-hole flange mount Size and class ½ inch class 150#RF ½ inch class 300#RF ½ inch class 600#RF ¾ inch class 150#RF ¾ inch class 300#RF ¾ inch class 600#RF 1 inch class 150#RF 1 inch class 300#RF 1 inch class 600#RF 1 ½ inch class 150#RF 1 ½ inch class 300#RF 1 ½ inch class 600#RF inch class 150#RF inch class 300#RF inch class 600#RF Special design, customer information to be supplied Materials and wetted parts SST 316L SST 316L with carbon pigmented Teflon lined diaphragm (good upto 500 F) Monel 400, mat. No Hastelloy C76, mat. No Tantal Special design, customer information to be supplied Flushing port(s) None 1 x ¼"NPT-female (available w/ SS, HC or MO) x ¼"NPT-female (available w/ SS, HC or MO) Special design, customer information to be supplied System fill Silicone oil DC Silicone oil DC High temperature oil (comes with metal gasket and stronger bolts) Halocarbon (for O -application) Silicone oil M5 Syltherm 800 DC704 silicone oil Fluorolube Special design, customer information to be supplied Length of capillary Direct mount 3 ft 5 ft 10 ft 15 ft 0 ft 5 ft 30 ft Special design, customer information to be supplied 1 3 A B C E F G J K L N P Q S T U Z A E G J K Z J 1 Y K 1 Y L 1 Y M 1 Y N 1 Y Selection and Ordering data Order No. Order code Further designs Please add -Z to Order No. and specifiy Order code Integrated flame path restriction DP "H" flange service Certification of calibration N.I.S.T. (0 % steps) Material conformance certificate Vacuum service (must be specified with HT oil) Calculation of span of transmitter (completed questionnaire to be attached) A 0 1 B 0 C 1 1 C 1 V 0 1 Y 0 5 C) Subject to export regulations AL: N, ECCN: EAR99. Siemens FI US Edition /147

148 Remote seals for transmitters and pressure gauges Diaphragm seal "flanged off-line low-pressure type" Diaphragm seal "flanged off-line low-pressure type" Dimensions (Connection to ASME B16.5) Instrument connection options welded capillary connection 1/4 NPT 1/ NPT Siemens AG 007 G Size Class G3 X A B C DM E ½" 150# ½"-13UNC ½" 300# ½"-13UNC ½" 600# ½"-13UNC ¾" 150# ½"-13UNC ¾" 300# 5 / 8 "-11UNC ¾" 600# 5 / 8 "-11UNC " 150# ½"-13UNC " 300# 5 / 8 "-11UNC " 600# 5 / 8 "-11UNC ½" 150# ½"-13UNC ½" 300# ¾"-10UNC ½" 600# ¾"-10UNC " 150# 5 / 8 "-11UNC " 300# 5 / 8 "-11UNC " 600# 5 / 8 "-11UNC DM = Effective diaphragm diameter G = Process connection G3 = Threaded bolt hole X = Number of bolt holes Class = Flange rating per ASME B16.5 Size = Nominal pipe size All dimensions in inches unless otherwise noted Diaphragm seal "flanged off-line low-pressure type", dimensions /148 Siemens FI US Edition

149 Selection and Ordering data Order No. Order code Diaphragm seal "flanged off-line low-pressure type" with flexible armored capillary, 316 stainless C) 7 M F steel upper housing SITRANS P for 7MF407 7 and 7MF4 7 7 (order separately) B Size and class ½ inch class 150#RF ½ inch class 300#RF ½ inch class 600#RF ¾ inch class 150#RF ¾ inch class 300#RF ¾ inch class 600#RF 1 inch class 150#RF 1 inch class 300#RF 1 inch class 600#RF 1 ½ inch class 150#RF 1 ½ inch class 300#RF 1 ½ inch class 600#RF inch class 150#RF inch class 300#RF inch class 600#RF Special design, customer information to be supplied Materials and wetted parts SST 316L SST 316L with carbon pigmented Teflon lined diaphragm (good upto 500 F) Monel 400, mat. No Hastelloy C76, mat. No Tantal Special design, customer information to be supplied Flushing port(s) None 1 x ¼"NPT-female (available w/ SS, HC or MO) x ¼"NPT-female (available w/ SS, HC or MO) Special design, customer information to be supplied System fill Silicone oil DC Silicone oil DC High temperature oil ) Halocarbon (for O -application) Silicone oil M5 Syltherm 800 DC704 silicone oil Fluorolube Special design, customer information to be supplied Length of capillary Direct mount 3 ft 5 ft 10 ft 15 ft 0 ft 5 ft 30 ft Special design, customer information to be supplied Further designs Please add -Z to Order No. and specifiy Order code Integrated flame path restriction DP "H" flange service Certification of calibration N.I.S.T. (0 % steps) Material conformance certificate Vacuum service (must be specified with HT oil) Calculation of span of transmitter (completed questionnaire to be attached) Remote seals for transmitters and pressure gauges Diaphragm seal "flanged off-line low-pressure type" A B C E F G J K L N P Q S T U Z A E G J K Z J 1 Y K 1 Y L 1 Y M 1 Y Siemens AG N 1 Y A 0 1 B 0 C 1 1 C 1 V 0 1 Y 0 5 Selection and Ordering data Order No. Order code Diaphragm seal "flanged off-line low-pressure type" with flexible armored capillary, 316 stainless steel upper housing SITRANS P for 7MF (order separately) C) 7 M F B Size and class ½ inch class 150#RF ½ inch class 300#RF ½ inch class 600#RF ¾ inch class 150#RF ¾ inch class 300#RF ¾ inch class 600#RF 1 inch class 150#RF 1 inch class 300#RF 1 inch class 600#RF 1 ½ inch class 150#RF 1 ½ inch class 300#RF 1 ½ inch class 600#RF inch class 150#RF inch class 300#RF inch class 600#RF Special design, customer information to be supplied Materials and wetted parts SST 316L SST 316L with carbon pigmented Teflon lined diaphragm (good upto 500 F) Monel 400, mat. No Hastelloy C76, mat. No Tantal Special design, customer information to be supplied Flushing port(s) None 1 x ¼"NPT-female (available w/ SS, HC or MO) x ¼"NPT-female (available w/ SS, HC or MO) Special design, customer information to be supplied System fill Silicone oil DC Silicone oil DC High temperature oil ) Halocarbon (for O -application) Silicone oil M5 Syltherm 800 DC704 silicone oil Fluorolube Special design, customer information to be supplied Length of capillary 3 ft 5 ft 10 ft 15 ft 0 ft 5 ft 30 ft Special design, customer information to be supplied Further designs Please add -Z to Order No. and specifiy Order code Integrated flame path restriction Certification of calibration N.I.S.T. (0 % steps) Material conformance certificate Vacuum service (must be specified with HT oil) Calculation of span of transmitter (completed questionnaire to be attached) C) Subject to export regulations AL: N, ECCN: EAR99. A B C E F G J K L N P Q S T U Z A E G J K Z J 1 Y K 1 Y L 1 Y M 1 Y N 1 Y A 0 C 1 1 C 1 V 0 1 Y 0 5 C) Subject to export regulations AL: N, ECCN: EAR99. Siemens FI US Edition /149

150 Remote seals for transmitters and pressure gauges Flushing rings Overview Flushing ring Flushing rings are required for flange-mounted and pancake type remote seals (Order No. 7MF MF493) if the danger exists that the process conditions and the geometry of the connection could cause the medium to form deposits or blockages. The flushing ring is clamped between the process flange and the remote seal. Deposits can be flushed away from the diaphragm through the holes in the side, or the pressure volume can be vented. Different nominal diameters and forms permit adaptation to the respective process flange. Process connection For flanges to EN and ASME: DN 50, 80, 100, 15; PN or DN inch, 3 inch, 4 inch, 5 inch; Class Standard design Material: CrNi-Stahl, mat. No /316L Sealing faces and flushing holes: See Ordering data Design Siemens AG 007 Technical specifications Flushing ring for remote seals of pancake and flange design Nom. diam. Nom. press. DN 50 PN PN 100 DN 80 PN PN 100 DN 100 PN PN 100 DN 15 PN PN 100 inch Class class inch Class class inch Class class inch Class class 600 Sealing face To EN Form B1 Form B Form D/Form D Form C/Form C Form C/Form C Form E Form F To ASME B16.5 Flushing holes ( off), female thread: Material Dimensional drawings RF AA RFSF RJT ring groove G¼ G½ ¼-18NPT ½-14NPT Stainless steel /316L h Thread Remote seal flange Flushing outlet Gasket Measuring point flange Installation example Flushing Spülring Dichtung Flushing inlet d i d 4 Connection to EN DN PN d 4 d i h Weight (mm) (bar) (mm) (mm) (mm) (kg) Connection to ASME B 16.5 DN Class d 4 d i h Weight inch mm (inch) mm (inch) mm (inch) kg (lb) (3.6) 6 (.44) 30 (1.18) 0.60 (1.3) (5) 9 (3.6) 30 (1.18) 1.05 (.31) (6.18) 9 (3.6) 30 (1.18).85 (6.8) (7.3) 16 (4.96) 30 (1.18) 3.30 (7.8) Flushing ring, dimension drawing /150 Siemens FI US Edition

151 Siemens AG 007 Remote seals for transmitters and pressure gauges Flushing rings Selection and Ordering data Order No. Ord. code Flushing ring 7 M F for remote seals 7MF4900 to 7MF Nom. diam. Nom. press. inch Class G 3 inch Class H 4 inch Class J 5 inch Class K Other version Z J 1 Y Add Order code and plain text: Nominal diameter:...; Nominal pressure:... Sealing face ASME B RF AA M -RFSF Q - RJT ring groove R Other version Z K 1 Y Add Order code and plain text: Sealing face:... Flushing holes ( off) Female thread G¼ 1 Female thread G½ Female thread ¼-18 NPT 3 Female thread ½-14 NPT 4 Material Stainless steel 316L 0 Other version 9 M 1 Y Add Order code and plain text: Material:... Further designs Please add -Z to Order No. and specifiy Order code Acceptance test certificate B to EN 1004, section 3.1.B C 1 Siemens FI US Edition /151

152 Remote seals for transmitters and pressure gauges Diaphragm seal with quick connection Siemens AG 007 Diaphragm seal with quick connection, with slotted union nut Dimensions (connection to ASME B16.5) Diaphragm seal with quick connection, Tri-Clamp connection Dimensions (connection to ASME B16.5) Type 7MF4840 with union nut DN [mm] MWP [psi] A [mm] B C DM E G1 Diaphragm seal with quick connection, with slotted union nut Weight [lbs] Rd 5 x 1 / ¼"-NPT Rd 58 x 1 / or Rd 65 x 1 / ½"-NPT.5 female Rd 78 x 1 / Type 7MF4840 with male thread DN MWP A Weight B C DM E G1 [mm] [psi] [mm] [lbs] Rd 65 x 1 / ¼"-NPT Rd 78 x 1 / or ½"-NPT female 3.0 DM = Effective diaphragm diameter MWP = Maximum Working 50 F G1 = Instrument connection DN = Nominal pipe size All dimensions in inches unless otherwise noted Diaphragm seal with quick connection, with male thread, dimensions Size MWP Weight A B C DM E G1 [in] [psi] [lbs] ¼"-NPT 1.7 or ½"-NPT female DM = Effective diaphragm diameter MWP = Maximum Working 50 F, higher rating with appropriate clamping device G1 = Instrument connection Size = Nominal pipe size All dimensions in inches unless otherwise noted Diaphragm seal with quick connection, Tri-Clamp connection, dimensions /15 Siemens FI US Edition

153 Siemens AG 007 Remote seals for transmitters and pressure gauges Diaphragm seal with quick connection Diaphragm seal with quick connection, "i"-line (Cherry Burrel - male) Dimensions (connection to ASME B16.5) Size [in] MWP [psi] A B C DM E F G1 Weight [lbs] ¼"-NPT or ½"-NPT female.4 DM = Effective diaphragm diameter MWP = Maximum Working 50 F, higher rating with appropriate clamping device G1 = Instrument connection Size = Nominal pipe size All dimensions in inches unless otherwise noted Diaphragm seal with quick connection, "i"-line (Cherry Burrel - male), dimensions Selection and Ordering data Order No. Order code Diaphragm seal with quick connection for gage pressure transmitter SITRANS P 7MF and 7MF4 7 7 (order separately) C) 7 M F A B made of 316 SS Process connection DIN with slotted union nut DN 5/PN 40 DN 3/PN 40 DN 40/PN 40 DN 50/PN 5 DN 65/PN 5 DN 80/PN 5 DIN with screw necks DN 5/PN 40 DN 3/PN 40 DN 40/PN 40 DN 50/PN 5 DN 65/PN 5 DN 80/PN 5 Tri-Clamp Connection 1 ½" 600 psi " 550 psi ½" 450 psi 3" 350 psi Varivent (Tuchenhagen) Size 513 Size Sanitary (4" Tank Spud) " extension 6" extension "I"-Line (Cherry Burrell - male) 1 ½" 500 psi " 450 psi 3" 350 psi 1 B 1 C 1 D 1 E 1 F 1 G B C D E F G 4 L 4 M 4 N 4 P 5 C 5 E 6 B 6 D 5 U 5 V 5 W Special design, customer information to be 9 Z H 1 Y supplied + J 1 Y System fill Vegetable oil Glycerin/Water 86.5/13.5 % Neobee M0 Mineral oil Special design, customer information to be supplied Length of capillary Direct Mount 3 ft 5 ft 10 ft 15 ft 0 ft 5 ft 30 ft Special design, customer information to be supplied Further designs Please add -Z to Order No. and specifiy Order code Certification of calibration N.I.S.T. (0 % steps) Material conformance certificate Vacuum service (must be specified with vegetable oil) Calculation of span of transmitter (completed questionnaire to be attached) C) Subject to export regulations AL: N, ECCN: EAR M 1 Y N 1 Y C 1 1 C 1 V 0 1 Y 0 5 Tank Spud accessories Sanitary Tank Spud Clamp (1 pc.) P 1 0 Sanitary Tank Spud O-ring (1 pc.) P 1 1 Sanitary Tank Spud Weldolet " extension P 1 (1 pc.) Sanitary Tank Spud Weldolet 6" extension P 1 3 (1 pc.) Siemens FI US Edition /153

154 Remote seals for transmitters and pressure gauges Diaphragm seal with quick connection Siemens AG 007 Selection and Ordering data Order No. Order code Diaphragm seal with quick connection for differential transmitter SITRANS P 7MF (order separately) made of 316 SS Process connection DIN with slotted union nut DN 50/PN 5 DN 65/PN 5 DN 80/PN 5 DIN with screw necks DN 50/PN 5 DN 65/PN 5 DN 80/PN 5 Tri-Clamp Connection " 550 psi ½" 450 psi 3" 350 psi 4" 50 psi "I"-Line (Cherry Burrell - male) 3" 350 psi 4" 00 psi Sanitary (4" Tank Spud) " extension 6" extension Special design, customer information to be supplied System fill Vegetable oil Glycerin/Water 86.5/13.5 % Neobee M0 Mineral oil Special design, customer information to be supplied Length of capillary 3 ft 5 ft 10 ft 15 ft 0 ft 5 ft 30 ft Special design, customer information to be supplied Further designs Please add -Z to Order No. and specifiy Order code Certification of calibration N.I.S.T. (0 % steps) Material conformance certificate Vacuum service (must be specified with vegetable oil) Calculation of span of transmitter (completed questionnaire to be attached) C) Subject to export regulations AL: N, ECCN: EAR99. C) 7 M F A B E 1 F 1 G E F G 4 M 4 N 4 P 4 Q 5 W 5 X 6 B 6 D 9 Z H 1 Y + J 1 Y M 1 Y N 1 Y C 1 1 C 1 V 0 3 Y 0 5 Tank Spud accessories Sanitary Tank Spud Clamp (1 pc., two required) P 1 0 Sanitary Tank Spud O-ring (1 pc., two required) P 1 1 Sanitary Tank Spud Weldolet " extension P 1 (1 pc., two required) Sanitary Tank Spud Weldolet 6" extension P 1 3 (1 pc., two required) /154 Siemens FI US Edition

155 Siemens AG 007 Remote seals for transmitters and pressure gauges Inline diaphragm seal with quick connection Inline diaphragm seal with quick connector, DIN with thread Dimensions (connection to ASME B16.5) Inline diaphragm seal with quick connection, Tri-clamp Dimensions (connection to ASME B16.5) DN [mm] MWP [psi] A B C E G H J L MB Rd34x1/ Rd5x1/ Rd65x1/ Rd78x1/ Rd95x1/ Rd110x1/ Rd130x1/ MB = Internal diameter MWP = Maximum Working 50 F, higher rating with appropriate clamping device DN = Nominal pipe size All dimensions in inches unless otherwise noted Inline diaphragm seal with quick connector, DIN with thread, dimensions Size MWP A B C E L MB [psi] ¾" " " " " " " " MB = Internal diameter MWP = Maximum Working 50 F, higher rating with appropriate clamping device Size = Nominal pipe size All dimensions in inches unless otherwise noted Inline diaphragm seal with quick connection, Tri-clamp, dimensions Siemens FI US Edition /155

156 Remote seals for transmitters and pressure gauges Inline diaphragm seal with quick connection Siemens AG 007 Inline diaphragm seal with quick connection, "i"-line (Cherry Burrell - male/male) Dimensions (connection to ASME B16.5) Size MWP [psi] A B C E H L MB 1.5" " " MB = Internal diameter MWP = Maximum Working 50 F, higher rating with appropriate clamping device Size = Nominal pipe size All dimensions in inches unless otherwise noted Inline diaphragm seal with quick connection, "i"-line (Cherry Burrell - male/male), dimensions Selection and Ordering data Order No. Order code Inline diaphragm seal with quick connection for transmitter SITRANS P for 7MF and 7MF4 7 7 (order separately) made of 316 SS C) 7 M F A B Process connection DIN with thread [C] DN 5/PN 40 DN 40/PN 40 DN 50/PN 5 DN 65/PN 5 DN 80/PN 5 DN100/PN 5 Tri-Clamp Connection B D E F G H 1" 600 psi 4 K 1 ½" 600 psi 4 L " 550 psi 4 M ½" 450 psi 4 N 3" 350 psi 4 P "I"-Line (Cherry Burrell - male/male) 1" 500 psi 5 R 1 ½" 500 psi 5 U " 450 psi 5 V 3" 350 psi 5 W Special design, customer information to be 9 Z H 1 Y supplied + J 1 Y System fill Vegetable oil Glycerin/Water 86.5/13.5 % Neobee M0 Mineral oil Special design, customer information to be supplied Length of capillary Direct mount 3 ft 5 ft 10 ft 15 ft 0 ft 5 ft 30 ft Special design, customer information to be supplied Further designs Please add -Z to Order No. and specifiy Order code Certification of calibration N.I.S.T. (0 % steps) Material conformance certificate Vacuum service (must be specified with vegetable oil) Calculation of span of transmitter (completed questionnaire to be attached) C) Subject to export regulations AL: N, ECCN: EAR M 1 Y N 1 Y C 1 1 C 1 V 0 3 Y 0 5 /156 Siemens FI US Edition

157 Siemens AG 007 Remote seals for transmitters and pressure gauges Diaphragm seal "threaded design" G1 G A B DM E F Weight [lbs] ¼"-NPT or ½"-NPT ¼"-NPT or ½"-NPT 3.74 ¾"-NPT "-NPT G1 = Instrument connection, G = Process connection DM = Effective diaphragm diameter All dimensions in inches unless otherwise noted Diaphragm seal "threaded design" Diaphragm seal "threaded design" Dimensions (Connection to ASME B16.5) System fill port System fill port Instrument connection Process connection Instrument connection Selection and Ordering data Order No. Order code Diaphragm seal "threaded design" MWP 3675 psi with flexible armored capillary, 316 stainless C) 7 M F steel upper housing SITRANS P for 7MF407 7 and 7MF4 7 7 pressure (order separately) B Size and class ¼"NPT-female ½"NPT-female ¾"NPT-female 1"NPT-female Special design, customer information to be supplied Materials and wetted parts SST 316L SST 316L with carbon pigmented Teflon lined diaphragm (good upto 500 F) SST 316L with Hastelloy C76 diaphragm SST 316L with PFA coated diaphragm (good upto 500 F) Monel 400, mat. No Hastelloy C76, mat. No Hastelloy C76 lower housing with Tantalum diaphragm Special design, customer information to be supplied Flushing port(s) None 1 x ¼"NPT-female x ¼"NPT-female A B C D Z A E F D G J K Z J 1 Y K 1 Y 0 4 Special design, customer inform. to be supplied 9 L 1 Y System fill Silicone oil DC Silicone oil DC High temperature oil (comes with metal gasket and stronger bolts) Halocarbon (for O -application) Silicone oil M5 Syltherm 800 DC704 silicone oil Fluorolube Special design, customer inform. to be supplied 9 M 1 Y Length of capillary Direct mount 3 ft 5 ft 10 ft 15 ft 0 ft 5 ft 30 ft Special design, customer information to be supplied N 1 Y Optional 1/8 NPT or 1/4 NPT flushing connection Process connection Further designs Please add -Z to Order No. and specify Ord. code Integrated flame path restriction DP "H" flange service Certification of calibration N.I.S.T. (0 % steps) Material conformance certificate Vacuum service (must be specified with HT oil) Calculation of span of transmitter (completed questionnaire to be attached) A 0 1 B 0 C 1 1 C 1 V 0 1 Y 0 5 C) Subject to export regulations AL: N, ECCN: EAR99. Siemens FI US Edition /157

158 Remote seals for transmitters and pressure gauges Diaphragm seal "threaded, low-pressure design" Siemens AG 007 Diaphragm seal "threaded, low-pressure design" Dimensions (Connection to ASME B16.5) G1 G A B C DM E F ¼"-NPT or ½"-NPT Diaphragm seal "threaded, low-pressure design, dimensions Weight [lbs] ¼"-NPT ½"-NPT ¾"-NPT "-NPT G1 = Instrument connection G = Process connection DM = Effective diaphragm diameter All dimensions in inches unless otherwise noted Selection and Ordering data Order No. Order code Diaphragm seal "threaded, low-pressure design" MWP 1,500 psi with flexible armored capillary, 316 stainless C) 7 M F steel upper housing SITRANS P for 7MF407 7 and 7MF4 7 7 pressure (order separately) B Size and class ¼"NPT-female ½"NPT-female ¾"NPT-female 1"NPT-female Special design, customer information to be supplied Materials and wetted parts SST 316L SST 316L with carbon pigmented Teflon lined diaphragm 1) SST 316L with Hastelloy C76 diaphragm SST 316L with PFA coated diaphragm 1) Monel 400, mat. No Hastelloy C76, mat. No Hastelloy C76 lower housing with Tantalum diaphragm Special design, customer information to be supplied Flushing port(s) None 1 x ¼"NPT-female x ¼"NPT-female Special design, customer information to be supplied System fill Silicone oil DC Silicone oil DC High temperature oil (comes with metal gasket and stronger bolts) Halocarbon (for O -application) Silicone oil M5 Syltherm 800 DC704 silicone oil Fluorolube Special design, customer information to be supplied Length of capillary Direct mount 3 ft 5 ft 10 ft 15 ft 0 ft 5 ft 30 ft Special design, customer information to be supplied Further designs Please add -Z to Order No. and specifiy Order code Integrated flame path restriction Certification of calibration N.I.S.T. (0 % steps) Material conformance certificate Vacuum service (must be specified with HT oil) Calculation of span of transmitter (completed questionnaire to be attached) A B C D Z A E F D G J K Z J 1 Y K 1 Y L 1 Y M 1 Y N 1 Y A 0 1 C 1 1 C 1 V 0 1 Y 0 5 /158 Siemens FI US Edition

159 Siemens AG 007 Remote seals for transmitters and pressure gauges Diaphragm seal "threaded, low-pressure design" Selection and Ordering data Order No. Order code Diaphragm seal "threaded, low-pressure design" MWP 1,500 psi with flexible armored capillary, 316 stainless C) 7 M F steel upper housing SITRANS P for 7MF (order separately) B Size and class ¼"NPT-female ½"NPT-female ¾"NPT-female 1"NPT-female Special design, customer information to be supplied Materials and wetted parts SST 316L SST 316L with carbon pigmented Teflon lined diaphragm (good upto 500 F) SST 316L with Hastelloy C76 diaphragm SST 316L with PFA coated diaphragm (good upto 500 F) Monel 400, mat. No Hastelloy C76, mat. No Hastelloy C76 lower housing with Tantalum diaphragm Special design, customer information to be supplied Flushing port(s) None 1 x ¼"NPT-female x ¼"NPT-female Special design, customer information to be supplied System fill Silicone oil DC Silicone oil DC High temperature oil (comes with metal gasket and stronger bolts) Halocarbon (for O -application) Silicone oil M5 Syltherm 800 DC704 silicone oil Fluorolube Special design, customer information to be supplied Length of capillary 3 ft 5 ft 10 ft 15 ft 0 ft 5 ft 30 ft Special design, customer information to be supplied Further designs Please add -Z to Order No. and specifiy Order code Integrated flame path restriction Certification of calibration N.I.S.T. (0 % steps) Material conformance certificate Vacuum service (must be specified with HT oil) Calculation of span of transmitter (completed questionnaire to be attached) A B C D Z A E F D G J K Z J 1 Y K 1 Y L 1 Y M 1 Y N 1 Y A 0 C 1 1 C 1 V 0 3 Y 0 5 C) Subject to export regulations AL: N, ECCN: EAR99. Siemens FI US Edition /159

160 Remote seals for transmitters and pressure gauges Inline diaphragm seal, wafer for pressure Siemens AG 007 Inline diaphragm seal, wafer for pressure Dimensions (Connection to ASME B16.5) Optional instruments connections welded capillary connection 1/4 NPT 1/ NPT Size Class A MB L Inline diaphragm seal, wafer for pressure, dimensions Weight [lbs] 1" " " " 150# - 500# " " " MB = Effective internal diameter Class = Flange rating per ASME B16.5 Size = Nominal pipe size All dimensions in inches unless otherwise noted Selection and Ordering data Order No. Order code Inline diaphragm seals wafer assembled to SITRANS P for 7MF and 7MF4 7 7 (order separately) C) 7 M F B Size and class 1 inch class 150 to ½ inch class 150 to 500 inch class 150 to inch class 150 to inch class 150 to 500 Special design, customer information to be supplied Materials and wetted parts SST 316L SST 316L with PFA-Coating (good upto 500 F) Monel 400, mat. No Hastelloy C76, mat. No Tantal Special design, customer information to be supplied System fill Silicone oil DC Silicone oil DC High temperature oil Halocarbon (for O -application) Silicone oil M5 DC704 silicone oil Fluorolube Special design, customer information to be supplied Length of capillary Direct mount 3 ft 5 ft 10 ft 15 ft 0 ft 5 ft 30 ft Special design, customer information to be supplied Further designs Please add -Z to Order No. and specifiy Order code Integrated flame path restriction Certification of calibration N.I.S.T. (0% steps) Material conformance certificate Vacuum service (must be specified with HT oil) Calculation of span of transmitter (completed questionnaire to be attached) C) Subject to export regulations AL: N, ECCN: EAR99. L M N P Q Z A D G J K Z J 1 Y K 1 Y M 1 Y N 1 Y A 0 1 C 1 1 C 1 V 0 1 Y 0 5 /160 Siemens FI US Edition

161 Siemens AG 007 Remote seals for transmitters and pressure gauges Inline diaphragm seal, wafer for pressure Selection and Ordering data Order No. Order code Inline diaphragm seals wafer assembled to SITRANS P for 7MF (order separately) C) 7 M F Size and class 1 inch class 150 to ½ inch class 150 to 500 inch class 150 to inch class 150 to inch class 150 to 500 Special design, customer information to be supplied Materials and wetted parts SST 316L SST 316L with PFA-Coating (good upto 500 F) Monel 400, mat. No Hastelloy C76, mat. No Tantal Special design, customer information to be supplied System fill Silicone oil DC Silicone oil DC High temperature oil Halocarbon (for O -application) Silicone oil M5 DC704 silicone oil Fluorolube Special design, customer information to be supplied Length of capillary 3 ft 5 ft 10 ft 15 ft 0 ft 5 ft 30 ft Special design, customer information to be supplied Further designs Please add -Z to Order No. and specifiy Order code Integrated flame path restriction Certification of calibration N.I.S.T. (0% steps) Material conformance certificate Vacuum service (must be specified with HT oil) Calculation of span of transmitter (completed questionnaire to be attached) B L M N P Q Z A D G J K Z J 1 Y K 1 Y M 1 Y N 1 Y A 0 C 1 1 C 1 V 0 3 Y 0 5 C) Subject to export regulations AL: N, ECCN: EAR99. Siemens FI US Edition /161

162 Remote seals for transmitters and pressure gauges Diaphragm seal, saddle Siemens AG 007 Diaphragm seal, saddle Dimensions (Connection to ASME B16.5) Radius To fit Pipe G1 R Pipe size O.D G1 = Instrument connection All dimensions in inches unless otherwise noted Diaphragm seal, saddle, dimensions ¼"-NPT or ½"-NPT female Clamp ring Spacer ring Upper housing Saddle flange Adapter GTAW /16 Siemens FI US Edition

163 Siemens AG 007 Remote seals for transmitters and pressure gauges Diaphragm seal, saddle Selection and Ordering data Order No. Order code Diaphragm seal, saddle, MWP 1,500 psi with flexible armored capillary or direct mount, C) 7 M F stainless steel upper housing and assemply hardware SITRANS P for 7MF or 7MF4 7 7 (order separately) B Nominal pipe size Not applicable (Retrofit for existing 7MF48 7 7).5" 3" 4" 5" 6" 8" Retrofit 3" Conoflow (6 bolt pattern) Retrofit 3" M&G style (8 bolt pattern) Retrofit 4" Conoflow (6 bolt pattern) Retrofit 4" M&G style (8 bolt pattern) Special design, customer information to be supplied Diaphragm material SST 316L SST 316L with carbon pigmented Teflon lined diaphragm (good upto 500 F) SST 316L with PFA coated diaphragm (good upto 500 F) Monel 400, mat. No Hastelloy C76, mat. No Tantal Special design, customer information to be supplied Saddle Material None (Retrofit order) Carbon steel, Ni plated SST 316L Hastelloy C76, mat. No Special design, customer information to be supplied System fill Silicone oil DC Silicone oil DC High temperature oil (comes with metal gasket and stronger bolts) Halocarbon (for O -application) Silicone oil M5 DC704 silicone oil Fluorolube Special design, customer information to be supplied Length of capillary Direct mount 3 ft 5 ft 10 ft 15 ft 0 ft 5 ft 30 ft Special design, customer information to be supplied Further designs Please add -Z to Order No. and specifiy Order code Integrated flame path restriction Certification of calibration N.I.S.T. (0 % steps) Material conformance certificate Vacuum service (must be specified with HT oil) Calculation of span of transmitter (completed questionnaire to be attached) N A B C D E G P Q R S Z A E D G J K Z J 1 Y K 1 Y L 1 Y M 1 Y N 1 Y A 0 1 C 1 1 C 1 V 0 1 Y 0 5 C) Subject to export regulations AL: N, ECCN: EAR99. Siemens FI US Edition /163

164 Remote seals for transmitters and pressure gauges Measuring setups Siemens AG 007 Measuring setups The following pages show examples of typical measuring setups for use of SITRANS P transmitters with and without remote seals, such as: Setups for transmitters with connection of remote seals, with associated equations for calculation. Questionnaires Checking of combination between transmitter and remote seal Setups for transmitters without remote seals, with associated equations for calculation Questionnaires For hydrostatic level measurements Installation Remote seals of pancake design are fitted between the connection flange of the measuring point and a blind flange. Remote seals of flanged design are fitted directly on the connection flange of the measuring point. The respective pressure rating of the blind flange or the flanged remote seal must be observed. The transmitter should always be installed below the connection flange, and below the lower connection flange in the case of differential pressure transmitters. When measuring at pressures above atmospheric, the transmitter can also be installed above the connection flange. When measuring at pressures below atmospheric, the transmitter must always be installed below the connection flange, and below the lower connection flange in the case of differential pressure transmitters. Offset of measuring range If there is a difference in height between the two connection flanges when measuring with two remote seals, an additional differential pressure results from the oil filling of the remote seal capillaries. This results in an offset of the actual measuring range and must be taken into account when adjusting the transmitter. An offset in the measuring range also occurs when combining a remote seal with a transmitter if the latter is not installed at the same height as the former. Transmitter output If the level, separation layer or density increase in closed vessels, the differential pressure and the output signal of the transmitter also increase. If an inverted relationship is desired between the differential pressure and the output signal, the start-ofscale and full-scale values of the SITRANS P must be interchanged. With open vessels, an increasing pressure is usually assigned to an increasing level, separation layer or density. Influence of ambient temperature The capillaries between the remote seal and the transmitter should be kept as short as possible to obtain the good transmission response. Temperature differences between the individual capillaries or between the individual remote seals should be avoided. If the complete setup is exposed to temperature variations, errors result from the thermal expansion of the filling liquid in the capillaries, in the remote seals and in the connection units of the transmitters. Notes When measuring separation layers, ensure that the layer is positioned between the two spigots. Also ensure that the level in the vessel is always above the top spigot. When measuring density, make sure that the level of the medium remains constant. The level is usually above the top spigot. Possible combinations of transmitter and remote seal Installation type Transmitter Remote seal A/B 7MF4033 and 7MF4034 7MF4800, 7MF4810, 7MF480, 7MF486, 7MF487, 7MF4840, 7MF4850, 7MF4861, 7MF486, 7MF4880 and 7MF4890 C1/C D E G/H/J 7MF433 and 7MF434 7MF4333 and 7MF4334 7MF4433 and 7MF4434 7MF4433 and 7MF4434 7MF4433 and 7MF4434 7MF4800, 7MF4810, 7MF480, 7MF486, 7MF487, 7MF4840, 7MF4850, 7MF4861, 7MF486, 7MF4880 and 7MF4890 7MF4801 and 7MF481 7MF4803, 7MF483, 7MF488, 7MF4843, 7MF4863 and 7MF4883 7MF4813 7MF4803, 7MF483, 7MF488, 7MF4843, 7MF4863 and 7MF4883 (vacuum-proof design required) /164 Siemens FI US Edition

165 Siemens AG 007 Remote seals for transmitters and pressure gauges Measuring setups with remote seals Schematics Types of installation for pressure and level measurements (open vessels) Installation type A H O DH Installation type B H O DH Installation type A Start-of-scale: p MA = r FL g H U - r Oil g H 1 Full-scale: p ME = r FL g H O - r Oil g H 1 Installation type B Start-of-scale: p MA = r FL g H U + r Oil g H 1 H U H 1 Pressure transmitter Pressure transmitter above the measuring point below the measuring point H 1 7 m (3 ft), with halocarbon oil as filling liquid only H 1 4 m (13.1 ft) H U H 1 Full-scale: p ME = r FL g H O + r Oil g H 1 Legend p MA Start-of-scale value to be set p ME Full-scale value to be set r FL Density of medium in vessel r Oil Density of filling oil in the capillary to the remote seal g Local acceleration due to gravity H U Start-of-scale value H O Full-scale value H 1 Distance between vessel flange and pressure trans. Types of installation for absolute level measurements (closed vessels) Installation type C 1 Installation type C Installation type C 1 and C Start-of-scale: p MA = p START + r Oil g H 1 Full-scale: p ME = p END + r Oil g H 1 p abs H 1 p abs H 1 Legend p MA p ME p START p END r Oil g H 1 Start-of-scale value to be set Full-scale value to be set Start-of-scale value Full-scale value Density of filling oil in the capillary to the remote seal Local acceleration due to gravity Distance between vessel flange and pressure trans. Pressure transmitter for absolute pressure always below the measuring point: H 1 ³ 00 mm (7.9 inch) Type of installation for differential pressure and flow measurements Installation type D Filter monitoring H 1 H V Installation type D Start-of-scale: p MA = p START - r Oil g H V Full-scale: p ME = p END - r Oil g H V Legend p MA Start-of-scale value to be set p ME Full-scale value to be set p START Start-of-scale value p END Full-scale value r Oil Density of filling oil in the capillary to the remote seal g Local acceleration due to gravity Distance between the measuring points (spigots) H V H Siemens FI US Edition /165

166 Remote seals for transmitters and pressure gauges Measuring setups with remote seals Siemens AG 007 Types of installation for level measurements (closed vessels) Installation type E DH H V H O H U Installation type E Start-of-scale: p MA = r FL g H U - r Oil g H V Full-scale: p ME = r FL g H O - r Oil g H V Legend p MA Start-of-scale value to be set p ME Full-scale value to be set r FL Density of medium in vessel r Oil Density of filling oil in the capillary to the remote seal g Local acceleration due to gravity H U Start-of-scale value H O Full-scale value Distance between the measuring points (spigots) H V Installation type G Installation type H Installation type J H H 1 DH H 1 H V H O H 1 H H U H Pressure transmitter for differential pressure above the upper measuring point, no vacuum below the lower measuring point between the measuring points, no vacuum H 1 7 m (3 ft), with halocarbon oil as filling liquid only H 1 4 m (13.1 ft) H 7 m (3 ft), with halocarbon oil as filling liquid only H 4 m (13.1 ft) Installation type G, H and J Start-of-scale: p MA = r FL g H U - r Oil g H V Full-scale: p ME = r FL g H O - r Oil g H V Legend p MA p ME r FL r Oil Start-of-scale value to be set Full-scale value to be set Density of medium in vessel Density of filling oil in the capillary to the remote seal g H U H O H V Local acceleration due to gravity Start-of-scale value Full-scale value Distance between the measuring points (spigots) /166 Siemens FI US Edition

167 Siemens AG 007 Remote seals for transmitters and pressure gauges Measuring setups without remote seals Overview Notes For the separation layer measurement, the separation layer has to be positioned between the two spigots. Schematics Pressure transmitters for differential pressure, for flanging Measuring setups for open containers Also you must make sure that the level in the container is always above the top spigot. When measuring density, make sure that the level of the medium remains constant. The level should be above the top spigot Level measurement Full-scale value Start-of-scale: p MA = r g H U Full-scale: p ME = r g H O Ho H u Start-of-scale value r Legend p MA p ME r g H U H O Start-of-scale value to be set Full-scale value to be set Density of medium in vessel Local acceleration due to gravity Start-of-scale value Full-scale value + Separation layer measurement Ho Hu Constant level = full-scale value Separation layer Start-of-scale value r r 1 Start-of-scale: p MA = g (H U r 1 + (H O - H U ) r ) Full-scale: p ME = r 1 g H O Legend p MA Start-of-scale value to be set p ME Full-scale value to be set r 1 Density of heavier liquid r Density of lighter liquid g Local acceleration due to gravity H U Start-of-scale value H O Full-scale value + Density measurement Constant level Start-of-scale: Full-scale: p MA = r MIN g H O p ME = r MAX g H O H o r Legende p MA p ME r MIN r MAX g H O Start-of-scale value to be set Full-scale value to be set Minimum density of medium in vessel Maximum density of medium in vessel Local acceleration due to gravity Full-scale value in m + Siemens FI US Edition /167

168 Remote seals for transmitters and pressure gauges Measuring setups without remote seals Siemens AG 007 Measuring setups for closed containers Static pressure Gas-filled negative pressure line Level measurement, Version 1 Start-of-scale: Dp MA = r g H U Full-scale: Dp ME = r g H O Ho Maximum level Full-scale value Start-of-scale value Legend Dp MA Dp ME r g H U H O Start-of-scale value to be set Full-scale value to be set Density of medium in vessel Local acceleration due to gravity Start-of-scale value Full-scale value H u r Transmitter reference line Maximum level Static pressure H o H u Constant level Max. separation layer Full-scale value Start-of-scale value r r 1 Static pressure r' H v Separation layer measurement Start-of-scale: Dp MA = g (H U r 1 + (H O - H U ) r - H V r' ) Full-scale: Dp ME = g (H O r 1 - H V r' ) Legend Dp MA Start-of-scale value to be set Dp ME Full-scale value to be set r 1 Density of heavier liquid with separation layer in vessel r Density of lighter liquid with separation layer r' Density of liquid in the negative pressure line (corresponding to the temperature existing there) g Local acceleration due to gravity H U Start-of-scale value H O Full-scale value H V Distance between the measuring points (spigots) Transmitter reference line /168 Siemens FI US Edition

169 s Siemens AG 007 Questionnaire (suitable for US market) for hydrostatic level measurements Order date: Processing date: Ordering code (customer): Ordering code (supplier): Customer reference: Measuring point: Position: Dimensions: Pressure: psi Temperature: K F Measuring range: inch ft (please mark with cross) Order No. of transmitter 1) : 7 M F 4 Z Y01 The different pressures and temperatures (densities) in the vessel and in the reference column result in an offset in the start-of-scale and full-scale values. The calibration data are determined in addition. It is also checked whether as a result of the range offset the ordered transmitter is suitable for this measurement. Please supply the following characteristic data so that we can calculate the measuring range, start-of-scale value, full-scale value and calibration data: Please mark type of boiler with a cross: Closed 1) Medium Open or not under pressure ) Licensed boiler pressure (absolute) psi Operating pressure (absolute) Lowest psi Normal 3) psi Highest psi Temperature of reference column (cold) F Distance between measuring points (dimension according to sketch) H V = ft Measuring range 4) = start-of-scale value to full-scale value Start-of-scale value H U = ft Full-scale value H O = ft Position of equalizing vessel above bottom measuring point if different from H V ft Please mark pressure correction of level with a cross: No Yes 4) 1) Reference line filled with condensation! Falling differential pressure with increasing level. ) Reference line without gas or filled with gas (air). Rising differential pressure with increasing level. 3) If not specified otherwise, this value is assumed as the calculation pressure of the level meter. The input signal (differential pressure) depends on the density (pressure and temperature). The influence is practically negligible for a lowest liquid level of 0 to 30% of the distance between the measuring points. 4) If a pressure correction of the level is required, the measuring range must be the same as the distance between the measuring points, and the transmitter is designed for the calculation pressure of 1 bar (absolute). Pressure correction means: the static pressure and the temperature are measured separately and calculated by a correction computer or measured-value computer. Siemens FI US Edition /169

170 s Siemens AG 007 Questionnaire (suitable for US market) Checking of transmitter/remote seal combinations * Customer: Tag. No.: * Plant: Item No.: * Ordering code: Person responsible: * Ordering department: Phone: * Transmitter Order No.: 7MF Yes Order No. of transmitter known? No * Order No. of remote seal: * 7MF 4 8 Z Suffixes Suffixes * Or without Order No.: Process connection * Standard: * Nominal diameter: * Nominal pressure: * Constructional design: Sandwich-type rem. seal Flanged remote seal Quick-release remote seal Clamp-on seal Other.: * Connection: Direct connection Capillary on one side; connection to: + side side Capillaries on both sides; Capillary length: ft * Vacuum-proof design Yes No * Wetted parts materials: * Tube: No Yes, inch long * Filling liquid * Miscellaneous Calculation of measuring range necessary? * Range to be set: * (without calculation) Start-of-scale: psi ( 4 ma) Full-scale: psi (0 ma) * Required measuring accuracy: Error: <. % of set span per : 18 F change in : temperature Please fill in this questionnaire and enclose with every order! Checked: No Name: Department: Date: /170 Siemens FI US Edition * Medium * Density of medium: kg/m 3 * Temperature of medium: Normal F Minimum F Maximum F * Ambient temperature on capillaries: Normal F Minimum F Maximum F * Ambient temperature on transmitter: Normal F Minimum F Maximum F * Operating pressure referred to absolute zero: psi abs * Does a vacuum occur during startup? No Yes If yes, associated temperature of medium: F * Installation type, see pages /165 and /166 A B C 1 C * Measuring: With install. types A, B, C 1, C and D: from to psi range With install. types A, B, G, H and J: H U = inch; H O = inch * Dimensions: With install. types A, B, C 1 and C : H 1 = inch With install. types D, G, H and J: H V = inch * Start-of-scale value following calculation: psi ( 4 ma) * Full-scale value following calculation: psi (0 ma) * Associated span: psi * Error to be expected: <, % of set span per 18 F change in temperature *) Values must be entered here! Yes E G H J D

171 Siemens AG 007 Fittings Technical description, Selection aid Overview All shut-off fittings can be secured onto walls, racks (7 mm grid) and vertical and horizontal pipes. This offers the advantage when assembling a plant that the shutoff fittings can be secured first and the lines for the medium and differential pressure connected to them. It is then possible to check all connections for leaks and to blow out or flush the pipes in order to remove dirt (welding residues, shavings etc.). The measuring instruments can be screwed onto the shut-off fittings right at the end when all piping has been completed. If an instrument has to be removed for maintenance, the fittings and pipes remain as they are. It is only necessary to close the valves the instrument can then be removed, and refitted following maintenance. Material acceptance test certificate to EN If a material acceptance test certificate to EN is required when ordering valve manifolds or shut-off fittings, please note that a single certificate is sufficient for each ordered item type. This means that you will only be charged for one certificate in the cost calculations. Selection of available shut-off valves Transmitters Shut-off valves for general applications Relative and absolute pressure transmitters with process connection G½" male thread e.g. SITRANS P, Z series 7MF A.. SITRANS P300 7MF SITRANS P DS III series 7MF and 7MF Relative and absolute pressure transmitter with G½"-14 NPT female thread e.g. SITRANS P Z series 7MF H.. SITRANS P300 7MF SITRANS P DS III series 7MF and 7MF Absolute pressure transmitter with process connection to IEC e.g. SITRANS P DS III series 7MF Double shut-off valve DN 5 7MF9011-4FA and 7MF9011-4GA -spindle valve manifold DN 5 7MF9411-5A. Page Shut-off valves for special applications Double shut-off valve DN 5 for crossover ½-NPT-F to G½ nipple connection 7MF9011-4EA /17 Double shut-off valve DN 5 for process connection ½-NPT 7MF9011-4DA /174 Page /17 /17 Differential pressure transmitter with process connection to IEC e.g. SITRANS P DS III series 7MF and 7MF For 3/5-spindle valve manifold DN 5 7MF9411-5B. and 7MF9411-5C. /174 Siemens FI US Edition /171

172 Fittings Double shut-off valves Siemens AG 007 Overview The double shut-off valves DN 5 are suitable for pressure gages and pressure transmitters and available in 4 versions: Sleeve-collar Sleeve-sleeve Sleeve-nipple Collar-collar Characteristic curves A diam. 7 approx C approx B diam approx. 90 bar 400 A Connection on device side: nipple to DIN 16 84, G½, SW 7 B Connection on measurement side: ½-14 NPT C Vent and test connection: ¼-18 NPT Operating pressure Operating temperature C 40 bar at 10 C 350 bar at 00 C Double shut-off valve DN 5 (sleeve-nipple) 7MF9011-4EA, dimensions in mm ½-14 NPT A C ¼-18 NPT Permissible operating pressure as a function of the permissible operating temperature 110 Selection and Ordering data Double shut-off valves DN 5 Material: X 6 CrNiMoTi (mat. No /316L), max. permissible working pressure 40 bar; Sleeve-sleeve Sleeve-nipple connection Sleeve-collar Collar-collar F) Subject to export regulations AL: 9I999, ECCN: N. Order No. F) 7MF9011-4DA F) 7MF9011-4EA F) 7MF9011-4FA F) 7MF9011-4GA A B C B ½-14 NPT Connection on device side: ½-14 NPT Connection on measurement side: ½-14 NPT Vent and test connection: ¼-18 NPT Double shut-off valve DN 5 (sleeve-collar) 7MF9011-4FA, dimensions in mm Dimensional drawings A B C approx C A 33 B diam. 6.4 approx. 90 Connection on device side: ½-14 NPT Connection on measurement side: ½-14 NPT Vent and test connection: ¼-18 NPT B C A Double shut-off valve DN 5 (sleeve-sleeve) 7MF9011-4DA, dimensions in mm A B C Connection on device side : ½-14 NPT Connection on measurement side: ½-14 NPT Vent and test connection: ¼-18 NPT Double shut-off valve DN 5 (collar-collar) 7MF9011-4GA, dimensions in mm /17 Siemens FI US Edition

173 Siemens AG 007 Fittings Double shut-off valves Overview The mounting set is suitable for the double shut-off valves 7MF A and for wall, rack and pipe mounting. Selection and Ordering data Mounting set for shut-off valves 7MF9011-4DA und -4EA made of stainless steel, scope of delivery: 1x mounting bracket, x hexagon screws M6x40, 1x mounting clip, x washers 8.4 to DIN 15; x hexagon nuts 8.4 to DIN EN 403 7MF9011-4FA und -4GA made of stainless steel, scope of delivery: 1x mounting bracket, x hexagon screws M6x10, 1x mounting clip, x washers 8.4 to DIN 15; x hexagon nuts 8.4 to DIN EN 403 Order No. F) 7MF9011-8AB F) 7MF9011-8AC F) Subject to export regulations AL: 9I999, ECCN: N. Dimensional drawings Mounting bracket (7MF9011-8AB) for shut-off valves 7MF9011-4DA and 7MF9011-4EA for wall, rack or pipe mounting, dimensions in mm 65 SW10 hex. 10 Ø R Mounting bracket (7MF9011-8AC) for shut-off valves 7MF9011-4FA and 7MF9011-4GA for wall, rack or pipe mounting, dimensions in mm Siemens FI US Edition /173

174 Fittings -, 3- and 5-spindle valve manifolds DN 5 Siemens AG 007 Overview Selection and Ordering data Order No. Valve manifolds DN 5 F) 7 M F for liquids and gases, for flanging to pressure transmitters for absolute and differential pressure, max. working pressure 40 bar (order accessory set with Order code) -spindle valve manifold 5 A 3-spindle valve manifold 5 B 5-spindle valve manifold 5 C Constructional and acceptance test without certificate A with factory test certificate EN B with material acceptance test certificate D EN F) Subject to export regulations AL: 9I999, ECCN: N. The -spindle, 3-spindle and 5-spindle valve manifolds 7MF are for pressure transmitters for absolute pressure or differential pressure. The valve manifolds are used to shut off the differential pressure lines and to check the pressure transmitter zero. The -spindle and the 5-spindle valve manifold enable in addition venting on the transmitter side and checking of the pressure transmitter characteristic. Benefits Max. working pressure 40 bar Each available in version for oxygen Application The spindle valve manifolds DN 5 are designed for liquids and gases Each is available in a version for oxygen on request Design All versions of the valve manifolds have a process connection ½- 14 NPT. The connection for the pressure transmitter is always designed as a flange connection to EN 61518, form B. The - spindle and the 5-spindle valve manifold have in addition a vent and test connection ¼-18 NPT. The valves have an external spindle thread. Materials used Component Material Mat. No. Housing X CrNiMo /316L Cones X 6 CrNiMoTi /316Ti Spindles X CrNiMo /316L Head parts X 5 CrNiMo /316 Packings PTFE - Function Functions of all valve manifolds: Shutting off the differential pressure lines Checking the pressure transmitter zero Additional functions of the -spindle and 5-spindle valve manifolds through the vent and test connection: Venting on the transmitter side Checking the pressure transmitter characteristic Selection and Ordering data Order code Order No. Further designs 1) Please add "-Z" to Order No. and specify Order code. Accessory set to DIN ) (connection between valve manifold and pressure transmitter) for valve manifold 7MF9411-5A. x screws M10x45 to DIN EN 4014; K15 7MF9411-7BB chromized steel x washers Ø 10.5 mm to DIN 15; 1x gasket made of PTFE, max. permissible 40 bar, 80 C x screws M10x45 to DIN EN 4014; K5 7MF9411-7BC stainless steel x washers Ø 10.5 mm to DIN 15, stainless steel; 1x gasket made of PTFE, max. permissible 40 bar, 80 C for valve manifolds 7MF9411-5B. and -5C. 4x screws M10x45 to DIN EN 4014; K16 7MF9411-6BB chromized steel 4x washers Ø 10.5 mm to DIN 15; x flat gaskets made of PTFE, max. permissible 40 bar, 80 C Flange connection with M10 screws only permissible up to PN x screws M10x45 to DIN EN 4014; K6 7MF9411-6BC stainless steel 4x washers Ø 10.5 mm to DIN 15, stainless steel; x flat gaskets made of PTFE, max. permissible 40 bar, 80 C Flange connection with M10 screws only permissible up to PN 160. Accessory set to EN (connection between valve manifold and pressure transmitter) for valve manifold 7MF9411-5A. x screws 7 / 16-0 UNF x K35 7MF9411-7DB 1¾ inch to ASME B18..1; chromized steel 1x gasket made of PTFE, max. permissible 40 bar, 80 C x screws 7 / 16-0 UNF x 1¾ inch to ASME B18..1; stainless steel 1x gasket made of PTFE, max. permissible 40 bar, 80 C K45 7MF9411-7DC /174 Siemens FI US Edition

175 Siemens AG 007 Fittings -, 3- and 5-spindle valve manifolds DN 5 Selection and Ordering data Order code Order No. Further designs 1) Please add "-Z" to Order No. and specify Order code. for valve manifold 7MF9411-5B. and -5C. 4x screws 7 / 16-0 UNF x K36 F) 7MF9411-5DB 1¾ inch to ASME B18..1; chromized steel x flat gaskets made of PTFE, max. permissible 40 bar, 80 C 4x screws 7 / 16-0 UNF x K46 F) 7MF9411-5DC 1¾ inch to ASME B18..1; stainless steel x flat gaskets made of PTFE, max. permissible 40 bar, 80 C Mounting plate for valve manifold, made of electrogalvanized sheet-steel - for wall mounting or for securing M11 F) 7MF9006-6EA on rack (7 mm grid), weight 0.5 kg Scope of delivery: 1 mounting plate with bolts for mounting on valve manifold - for pipe mounting, weight 0.7 kg M1 F) 7MF9006-6GA Scope of delivery: 1x mounting plate M11, x pipe brackets with nuts and washers (for pipe with max. Ø 60.3 mm) for valve manifold, made of stainless steel - for wall mounting or for securing M1 F) 7MF9006-6EC on rack (7 mm grid), weight 0.5 kg Scope of delivery: 1 mounting plate with bolts for mounting on valve manifold - for pipe mounting, weight 0.7 kg M F) 7MF9006-6GC Scope of delivery: 1x mounting plate M11, x pipe brackets with nuts and washers (for pipe with max. Ø 60.3 mm) Valve manifold 100 bar Suitable for oxygen for 7MF9411-5A. S1 for 7MF9411-5B. S13 for 7MF9411-5C. S14 1) When ordering accessory set or mounting together with the valve manifolds, please use Order code; otherwise use Order No. ) Flange connections to DIN 1913 only permissible up to 160! F) Subject to export regulations AL: 9I999, ECCN: N. Accessories Accessory set for -, 3- and 5-spindle valve manifolds -spindle valve manifold DN 5 K15: screws M10x45 to DIN EN 4014, washers, 1 flat gasket K35: screws 7 / 16-0 UNF x 1¾ inch to ASME B18..1, 1 flat gasket 3-spindle and 5-way valve manifold DN 5 K16: 4 screws M10x45 to DIN EN 4014, 4 washers, flat gaskets K36: 4 screws 7 / 16-0 UNF x 1¾ inch to ASME B18..1, flat gaskets Washers Ø 10.5 to DIN 15 Flat gaskets made of PTFE, max. 40 bar, 80 C Note: Flange connection with M10 screws only permissible up to PN 160! Mounting plate Made of electrogalvanized sheet-steel M11: For wall mounting or for securing on rack (7 mm grid) Scope of delivery: - 1 mounting plate with bolts for mounting on valve manifold M1: For pipe mounting Scope of delivery: - 1 mounting plate M11 - pipe brackets with nuts and washers for pipes with max. Ø 60.3 mm Valve manifold 100 bar, suitable for oxygen S1: For -way valve manifold S13: For 3-way valve manifold S13: For 5-way valve manifold Characteristic curves Operating pressure bar C Operating temperature Valve manifolds PN 5 (7MF ), permissible working pressure as a function of the permissible working temperature Siemens FI US Edition /175

176 Fittings -, 3- and 5-spindle valve manifolds DN 5 Siemens AG 007 Dimensional drawings ¼-18 NPT 55 C B ½-14 NPT A M10 Ø A Process connection: ½-14 NPT B Transmitter connection: Flange connection to EN , form B C Vent / test connection: ¼-18 NPT Valve design: external spindle thread -spindle valve manifold DN 5 (7MF9411-5A.), dimensions in mm Mounting plate 7MF (M11, M1) for valve manifold, dimensions in mm Schematics A A A C A A C 55 M10 diam B ½-14 NPT A B A Process connection B Transmitter connection C Blow-out-connection B -spindle, 3-spindle and 5-spindle valve manifold DN 5, connections B B B A Process connection: ½-14 NPT B Transmitter connection: flange connection to EN , form B Valve design: external spindle thread 3-spindle valve manifold DN 5 (7MF9411-5B.), dimensions in mm C ¼-18 NPT 55 M10 Ø B A ½-14 NPT A Process connection: ½-14 NPT B Transmitter connection: Flange connection to EN , form B C Vent / test connection: ¼-18 NPT Valve design: external spindle thread 5-spindle valve manifold DN 5 (7MF9411-5C.), dimensions in mm /176 Siemens FI US Edition

177 Siemens AG 007 Fittings Oval flange Overview Selection and Ordering data Oval flange with female thread ½-14 NPT, max. working pressure 40 bar, flange connection to DIN EN 61518, form A Order No. Material P50GH, mat. No.: F) 7MF9408-CE X CrNiMo 17 13, mat. No /316L F) 7MF9408-CL The oval flange 7MF9408-C. for pressure transmitters for absolute pressure and differential pressure has a ½-14 NPT female thread and is designed for max. operating pressure 400 bar. Accessories E13: screws M10x40 to DIN EN 476, washers, 1 O-ring (FPM 90) E34: screws 7 / 16-0 UNF x 1½ inch to ASME B18.3, 1 O-ring (FPM 90) E16: screws M10x40 to DIN EN ISO 476, washers, 1 flat gasket E36: screws 7 / 16-0 UNF x 1½ inch to ASME B18..1, 1 flat gasket Washers Ø 10.5 to DIN 15 Flat gaskets made of PTFE, max. 40 bar, 80 C O-ring to DIN 3771, 0 x.65 S FPM90, max. 40 bar, 10 C Note: M10 screws only permissible up to PN 160! Selection and Ordering data Order code Order No. Further designs Please add "-Z" to Order No. and specify Order code. Accessory set to DIN 1) x screws M10x40 to E13 F) 7MF9408-6AA DIN EN ISO 476; chromized steel x washers Ø 10.5 mm to DIN 15; 1x O-ring to DIN 3771, 0 x.65 - S - FPM90, max. permissble 40 bar, 10 C ) x screws M10x40 to E16 F) 7MF9408-6BA DIN EN ISO 476; chromized steel x washers Ø 10.5 mm to DIN 15; 1x flat gasket made of PTFE, max. permissible 40 bar, 80 C ) Accessory set to EN 1) x screws 7 / 16-0 UNF x E36 F) 7MF9408-5DA 1½ inch to ASME B 18..3; chromized steel 1x flat gasket made of PTFE, max. permissible 40 bar, 80 C x screws 7 / 16-0 UNF x E34 F) 7MF9408-5CA 1½ inch to ASME B 18..3; chromized steel 1x O-ring to DIN 3771, 0 x.65 - S - FPM90, max. permissble 40 bar, 10 C 1) When ordering accessory set together with the oval flange, please use Order code; otherwise use Order No. ) Flange connections with M10 screws only permissible up to PN 160! F) Subject to export regulations AL: 9I999, ECCN: N. Dimensional drawings Oval flange 7MF9408-C., dimensions in mm 7 Siemens FI US Edition /177

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure Z series for gage pressure Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens A 207 Overview Application The SITRANS P Compact pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials

More information

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview f gauge pressure Siemens AG 010 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection

More information

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure Siemens AG 204 Overview The pressure transmitter SITRANS P220 measures the gauge pressure of liquids, gases and vapors. Stainless steel measuring cell, fully welded Measuring ranges 2.5 to 600 bar (36.3

More information

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.

More information

sitrans p Operating Instructions (de/en) Edition 03/2004

sitrans p Operating Instructions (de/en) Edition 03/2004 (de/en) Edition 03/2004 sitrans p Messumformer für Food, Pharma und Biotechnik Transmitters for food, pharmaceuticals and biotechnologgy 7FM8010 Contents Information for the operator...27 Important security

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens AG 07 Overview Function U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/ Equipotential bonding Diaphragm The pressure

More information

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition Siemens AG 07 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure

More information

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI Siemens AG 06 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure

More information

SITRANS. Pressure transmitter SITRANS P, Z series for gauge and absolute pressure. Introduction. Safety instructions 2.

SITRANS. Pressure transmitter SITRANS P, Z series for gauge and absolute pressure. Introduction. Safety instructions 2. Introduction 1 Safety instructions 2 SITRANS Pressure transmitter SITRANS P, Z series for gauge and absolute pressure 7MF1564 Description 3 Assembly and connection 4 Technical data 5 Dimensional drawings

More information

Siemens AG Transmitters with WirelessHART 1/42 SITRANS P280 for gauge and abs. pressure. Transmitters for food, pharmaceuticals

Siemens AG Transmitters with WirelessHART 1/42 SITRANS P280 for gauge and abs. pressure. Transmitters for food, pharmaceuticals Siemens AG 07 / Product overview Single-range transmitters for general applications /5 SITRANS P00 for gauge and abs. pressure / SITRANS P0 for gauge pressure /6 SITRANS P0 for gauge pressure Transmitter

More information

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0. Pressure Transmitter for Marine and Offshore Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0. % FSO Nominal pressure from 0... 40 mbar up to 0... 0 bar Output signals -wire:

More information

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0. Precision Pressure Transmitter for Food ndustry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to EC 60770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 40 bar Output

More information

Pressure Measurement

Pressure Measurement Siemens AG 011 / Product overview Transmitters for basic requirements /4 SITRANS P Z for gauge and absolute pressure /10 SITRANS P50 for differential pressure /15 SITRANS P MPS (submersible sensor) Transmitter

More information

JUMO dtrans p30 Pressure Transmitter

JUMO dtrans p30 Pressure Transmitter 609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +49 661 600-0 Fax: +49 661 600-607 Phone: +44 179 6 55 Data Sheet 40466 Page 1/6 JUMO dtrans p0 Pressure Transmitter General application Pressure

More information

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor Precision- Pressure Transmitter for Food ndustry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to EC 60770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 40 bar Output

More information

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries Series 2000 ALL STAINLESS DESIGN EASY CALIBRATION WITHOUT TEST PRESSURE BY 3 PUSH BUTTONS ACCURACY 0,1% 4-20 ma AND HART PROTOCOL ATEX II

More information

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries Series 2000 ALL STAINLESS DESIGN EASY CALIBRATION WITHOUT TEST PRESSURE BY 3 PUSH BUTTONS ACCURACY 0,1% 4-20 ma AND HART PROTOCOL ATEX II

More information

Pressure transmitter PASCAL Ci4

Pressure transmitter PASCAL Ci4 Pressure transmitter PASCAL Ci4 for general application,type Series CI4100 Features Pressure transmitter for the measuring of relative and absolute pressures of gases, vapors and liquids High-resolution

More information

OPTIBAR P 1010 C Technical Datasheet

OPTIBAR P 1010 C Technical Datasheet Technical Datasheet Pressure transmitter with recessed diaphragm for general applications Wide variety thanks to modular design Measuring ranges up to 250 bar / 3750 psi High overload and temperature stability

More information

ED 701 Hygenic Pressure Transmitter

ED 701 Hygenic Pressure Transmitter ED 701 Hygenic Pressure Transmitter Hygienic process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response time < 25 ms (Option

More information

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor INDUSTRIAL INSTRUMENTS AND CONTROLS SPECIALIST Kent-Taylor 2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters Features Include Base accuracy : ±0.075% Span limits

More information

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement Model LH-20 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater

More information

A Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >

A Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit > A Higher Level of Performance Data Sheet Pressure and Level Transmitters For more information, please visit > www.hawkmeasure.com Description Intelligent pressure and level transmitters for all industries

More information

Hydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN

Hydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN Hydrostatic Continuous level measurement 8 Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 187 Hydrostatic Level and pressure measurement Measuring principle The pressure

More information

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement Model LH-20 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater

More information

Differential pressure

Differential pressure Differential pressure 9 Overview Page 200 VEGADIF 65 Page 202 Chemical seal Page 204 Accessory Page 208 199 VEGADIF For differential pressure, level and flow measurements Measuring principle The sensor

More information

High-performance submersible pressure transmitter For level measurement Model LH-10

High-performance submersible pressure transmitter For level measurement Model LH-10 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well

More information

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

Type N-10, N-11 Hazardous Area Non-incendive Transmitters Electronic Pressure Catalog > Hazardous Area > N-10, N-11 Type N-10, N-11 Hazardous Area Non-incendive Transmitters Applications Natural gas compressors Wellhead monitoring Pipeline pressure General industrial

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure Remote seals for transmitters and pressure gauges Technical description Overview In many cases the pressure transmitter and the measured medium have to be physically separated. It is then necessary to

More information

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements

More information

How to specify a product. Process Sensors and Mechanical Instruments

How to specify a product. Process Sensors and Mechanical Instruments How to specify a product Process Sensors and Mechanical Instruments Keep the overview. Here is some guideline information on how to specify our products. Intended as supplementary help to specification

More information

SITRANS P pressure transmitters The best in pressure measurement. sitrans

SITRANS P pressure transmitters The best in pressure measurement. sitrans SITRANS P pressure transmitters The best in pressure measurement sitrans The SITRANS P family The right choice every time No two processes are alike. No two infrastructures are alike. No two ambient conditions

More information

Siemens AG psi (6 bar) 145 psi (10 bar) 464 psi (32 bar) 1450 psi (100 bar) 3626 psi (250 bar) 8700 psi (600 bar) psi (800 bar)

Siemens AG psi (6 bar) 145 psi (10 bar) 464 psi (32 bar) 1450 psi (100 bar) 3626 psi (250 bar) 8700 psi (600 bar) psi (800 bar) Technical specifications SITRANS P, DS III series Input Measured variable Spans (infinitely adjustable) or nominal measuring range and max. permissible test pressure HART Gauge pressure Span (min.... max.)

More information

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05 IDL0 Battery Powered Precision Digital Gauge for Leak Testing Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger

More information

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement Model LH-20 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater

More information

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

DM01. Please visit our website:  Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05 DM0 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing

More information

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor.  Type: ETd 04. class 0.05 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 100 mbar up to 0... 400 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing

More information

High-performance submersible pressure transmitter For level measurement Model LH-10

High-performance submersible pressure transmitter For level measurement Model LH-10 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well

More information

Type S-10, S-11 General Purpose Pressure Transmitters

Type S-10, S-11 General Purpose Pressure Transmitters Electronic Pressure Catalog > General Purpose > S-10, S-11 Type S-10, S-11 General Purpose Pressure Transmitters Applications Hydraulics and pneumatics Test equipment Pump and compressor control Liquid

More information

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing Ø

More information

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0. LMP 07 Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % / 0. % FSO Nominal pressure from 0... mho up to 0... 50 mho Output signals -wire: 4... 0 ma -wire: 0...

More information

Differential Pressure Transmiter

Differential Pressure Transmiter Differential Pressure Transmiter Description The is an economical alternative to established differential pressure transmitters. It combines state of the art electronics and a high performance sensor;

More information

Expert Hydrostatic Level Transmitters

Expert Hydrostatic Level Transmitters Expert Hydrostatic s General Features MJK Expert hydrostatic level transmitters are designed for level measurement by submerging the transmitter in open channels, drains and tanks. Expert hydrostatic level

More information

L3 Pressure and Level transmitter

L3 Pressure and Level transmitter SENSORS FOR AND BIOPHARMA. Product Information L3 L3 Pressure and Level transmitter Range of applications Hydrostatic Level measurement in dynamic temperature environments Pressure measurement in pipes

More information

UNIK 5600/5700 Marine Certified Pressure Sensing Platform

UNIK 5600/5700 Marine Certified Pressure Sensing Platform GE Measurement & Control UNIK 5600/5700 Marine Certified Pressure Sensing Platform The new UNIK 5600/5700 carries marine certification for most zones on-board ship, as well as Intrinsically Safe certifications.

More information

Bourdon tube pressure gauge for diaphragm seals

Bourdon tube pressure gauge for diaphragm seals Bourdon tube pressure gauge for diaphragm seals and switch function, Type series BR42.. Features Bourdon tube pressure gauge for diaphragm seal and switch function Nominal range -1 3 bar to -1 15 bar,

More information

Pressure Transmitter P41

Pressure Transmitter P41 SENSORS FOR AND BIOPHARMA. Product Information P41 Pressure Transmitter P41 Application/Specified usage Pressure measurement in pipes and tanks For process temperatures up to 250 C (428 F) with optional

More information

Level switches Series LD Vibrating fork level switch for liquids and solids

Level switches Series LD Vibrating fork level switch for liquids and solids Level switches Series LD Vibrating fork level switch for liquids and solids Robust and compact Suitable for liquids (model LD61) and solids (model LD60) No moving parts, low maintenance Corrosion resistant

More information

Climatic Independent Level Sensor LAR

Climatic Independent Level Sensor LAR 1 Product Information LAR-361 LAR-761 Climatic Independent Level Sensor LAR Application / Specified usage Authorizations Hydrostatic level measurement in humid ambiance Special applicable for exterior

More information

Level switches Series LD Vibrating fork level switch for liquids and solids

Level switches Series LD Vibrating fork level switch for liquids and solids Level switches Series LD Vibrating fork level switch for liquids and solids Robust and compact Suitable for liquids (model LD61) and solids (model LD60) No moving parts, low maintenance Corrosion resistant

More information

C-Flow Coriolis Mass Flow Meters

C-Flow Coriolis Mass Flow Meters Coriolis Mass Flow Meters Ready for Take Off The New Compact C-Flow Küppers Elektromechanik GmbH The C-Flow The C-Flow Coriolis Mass Meters consist of two components: KCE Transmitter KCM Transducer 2 KEM

More information

9700 Transmitter Submersible hydrostatic level transmitter

9700 Transmitter Submersible hydrostatic level transmitter Specification sheet IP0078 October 2007 Level 9700 Transmitter Submersible hydrostatic level transmitter Description The 9700 series hydrostatic level transmitter is designed to perform in the most arduous

More information

Siemens AG Span (min... max.) Max. perm. test. 87 psi (6 bar) 145 psi (10 bar) 464 psi (32 bar) 1450 psi (100 bar)

Siemens AG Span (min... max.) Max. perm. test. 87 psi (6 bar) 145 psi (10 bar) 464 psi (32 bar) 1450 psi (100 bar) SITRANS P S III for gauge/absolute pressure, Technical specifications SITRANS P S III series for gauge and absolute pressure, HART PROFIBUS PA and FOUNATION Fieldbus Input of gauge pressure, Measured variable

More information

Gas density monitor With integrated transmitter Model GDM-100-TI

Gas density monitor With integrated transmitter Model GDM-100-TI SF 6 gas solutions Gas density monitor With integrated transmitter Model GDM-100-TI grid Products WIKA data sheet SP 60.05 for further approvals see page 5 Applications Gas density monitoring of closed

More information

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. Supplied with an electric input signal of 4 to 20

More information

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6 P9000 High accuracy through digital compensation High thermal stability Rugged stainless steel construction Ideal for test stands High burst pressure limit DESCRIPTION The P9000 Series is a range of advanced,

More information

Precision pressure sensor Basic version Model CPT6020

Precision pressure sensor Basic version Model CPT6020 Calibration Precision pressure sensor Basic version Model CPT6020 WIKA data sheet CT 25.13 Applications Calibration technology High-accuracy pressure monitoring Pressure sensing in critical applications

More information

ATM/Ex - Analog Pressure Transmitter

ATM/Ex - Analog Pressure Transmitter Pressure Transmitter - ATEX certified ATM/Ex - Analog Pressure Transmitter CUSTOMER BENEFITS Certificate: ATEX & EAC Fast customization thanks to configurable product design Demountable electrical connector

More information

NivuBar Plus II

NivuBar Plus II NivuBar Plus II Ceramic diaphragm Capacitive measuring cell 2-wire technology (output 4-20 ma) Integrated overload protection Extensive, almost front flush diaphragm Ex approval for zone 0 as standard

More information

ATM.ECO/IS - Analog Transmitter with Temperature compensation

ATM.ECO/IS - Analog Transmitter with Temperature compensation Pressure Transmitter - FM / FM-C certified ATM.ECO/IS - Analog Transmitter with Temperature compensation CUSTOMER BENEFITS Certificate: FM, FM-C & IECEx & ATEX Entry level series into precision pressure

More information

ATM - Analog Pressure Transmitter

ATM - Analog Pressure Transmitter Pressure Transmitter ATM - Analog Pressure Transmitter CUSTOMER BENEFITS Fast customization thanks to configurable product design Demountable electrical connector option to allow adjustment of zero and

More information

AMS 2710 PCB pressure sensor module with V output

AMS 2710 PCB pressure sensor module with V output FEATURES Universal pressure sensor module with 0.. 10 V voltage output Fully calibrated and temperature compensated sensor module Variants for (bidirectional) differential, gage, absolute and barometric

More information

Level transmitter LT 100

Level transmitter LT 100 KROHNE 09/2001 7.02363.21.00 GR/PRINTO Level transmitter LT 100 Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters

More information

3.0 Pressure Transmitter Selection

3.0 Pressure Transmitter Selection 3.0 Pressure Transmitter Selection Each Tronic Line pressure transmitter has different features to meet specific performance, environmental, and price requirements. It is not possible to describe every

More information

Hand-held pressure calibrator with integrated pump Model CPH6600

Hand-held pressure calibrator with integrated pump Model CPH6600 Calibration technology Hand-held pressure calibrator with integrated pump Model CPH6600 WIKA data sheet CT 16.01 Applications Calibration service companies and service industry Measurement and control

More information

High-speed pressure sensor Model CPT6140

High-speed pressure sensor Model CPT6140 Calibration technology High-speed pressure sensor Model CPT6140 WIKA data sheet CT 25.11 Applications Testing technology Calibration technology Laboratories and maintenance shops Leak and burst applications

More information

ATM/Ex - Intrinsically Safe Analog Pressure Transmitter - ATEX / IECEx Certified

ATM/Ex - Intrinsically Safe Analog Pressure Transmitter - ATEX / IECEx Certified Intrinsically safe pressure transmitters ATM/Ex - Intrinsically Safe Analog Pressure Transmitter - ATEX / IECEx Certified CUSTOMER BENEFITS Certificate: ATEX & IECEx Fast customization thanks to configurable

More information

KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media

KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media FEATURES 50 mbar to 400 bar, 5 to 6000 psi gage or absolute pressure For many industrial gases and liquids 00, 0545, 05, 6 or 40 ma output Field interchangeable EMC according to EN 66-8 MEDIA COMPATIBILITY

More information

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel KROHNE 04/2003 7.02445.71.00 GR 7000 Series OPTIMASS Mass Flowmeters with single straight measuring tube Titanium Hastelloy Stainless Steel One tube no limits No limits with tube material No limits with

More information

ATM.ECO - Analog Pressure Transmitter

ATM.ECO - Analog Pressure Transmitter Pressure Transmitter ATM.ECO - Analog Pressure Transmitter CUSTOMER BENEFITS Entry level series into precision pressure measurement High measurement accuracy is ensured by sophisticated digital temperature

More information

ATM.1ST/Ex - High Precision Transmitter

ATM.1ST/Ex - High Precision Transmitter Pressure Transmitter - ATEX / IECEx certified ATM.1ST/Ex - High Precision Transmitter CUSTOMER BENEFITS Certificate: ATEX, IECEx & EAC High measurement accuracy is ensured by sophisticated digital temperature

More information

Climatic Independent Level Sensor LAR

Climatic Independent Level Sensor LAR 3 JAHRE GEWÄHRLEISTUNG 1 Product Information LAR-361 LAR-761 f o o d Climatic Independent Level Sensor LAR 3 3 Y R S W A R R A N T Y Application / Specified usage Authorizations Hydrostatic level measurement

More information

Torque Tube TB300 Digital Transmitters

Torque Tube TB300 Digital Transmitters Page 1 of 7 7E.300-E Issue 4-2009 Description Series TB300 torque tube liquid level instruments utilize the buoyancy exerted on a displacer when immersed in a liquid. The buoyancy on the displacer is proportional

More information

1 Overview. Pressure Measurement Remote seals for transmitters and pressure gauges SITRANS P320/P420. 1/352 Siemens FI US Edition

1 Overview. Pressure Measurement Remote seals for transmitters and pressure gauges SITRANS P320/P420. 1/352 Siemens FI US Edition Siemens AG 08 Technical description Overview In many cases the pressure transmitter and the measured medium have to be physically separated. It is then necessary to use a remote seal. The remote seals

More information

PRODUCT CATALOGUE DIGITAL GAUGES

PRODUCT CATALOGUE DIGITAL GAUGES PRODUCT CATALOGUE DIGITAL GAUGES Pressure AT THE HIGHEST LEVEL Successful medium-sized companies are not successful because they are active in many areas, but rather because they concentrate on one area

More information

Mechanical Pressure Measurement

Mechanical Pressure Measurement Mechanical Pressure Measurement Differential Pressure Gauges Model GDP, Universal Version, with Diaphragm Element High Overpressure Safety PN 40, 100, 250 or 400 Applications Differential pressure measurement

More information

SITRANS P DS III/P410 with. FOUNDATION Fieldbus FF SITRANS. Pressure transmitter SITRANS P DS III/P410 with FOUNDATION Fieldbus FF.

SITRANS P DS III/P410 with. FOUNDATION Fieldbus FF SITRANS. Pressure transmitter SITRANS P DS III/P410 with FOUNDATION Fieldbus FF. SITRANS P DS III/P410 with FOUNDATION Fieldbus FF SITRANS Pressure transmitter SITRANS P DS III/P410 with FOUNDATION Fieldbus FF Operating Instructions Introduction 1 Safety instructions 2 Description

More information

Pressure Switches Application Guideline

Pressure Switches Application Guideline Pressure Switches Application Guideline Product Overview The Fema Pressure Switch product portfolio provides devices suitable for many applications. The portfolio contains Special functions and equipment

More information

GA24 Technical Datasheet

GA24 Technical Datasheet GA24 Technical Datasheet Variable-area flowmeter Sturdy construction for several applications Local indication without auxiliary power Replaceable mounting parts KROHNE CONTENTS GA24 1 Product features

More information

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. An electric standardized signal of 4 to 20 ma or

More information

P900. P900, Datenblatt Seite 1 DESCRIPTION

P900. P900, Datenblatt Seite 1 DESCRIPTION , Datenblatt Seite 1 Field proven rugged construction High overpressure capability High reliability for demanding environments Application specific customization Excellent media compatibility Shock and

More information

Operating Instructions for Intrinsically Safe Pressure Transmitters Series DMG/******** for Hazardous Application in Coal Mining Industry

Operating Instructions for Intrinsically Safe Pressure Transmitters Series DMG/******** for Hazardous Application in Coal Mining Industry Operating Instructions for Intrinsically Safe ressure Transmitters Series DMG/******** for Hazardous Application in Coal Mining Industry Contents 1. Introduction 2. Abbreviations, symbols 3. Important

More information

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications Technical Datasheet D Series SMART Pressure Transmitter Model: DPC-2000 Key Features ATEX - Flameproof and Intrinsically Safe IECEx - Flameproof and Intrinsically Safe SIL 2 certificate Compliant to NAMUR

More information

Design Features. General Description

Design Features. General Description Model thermal Mass Flow Controllers are designed to indicate and control set flow rates of gases. The combines the characteristics and accuracy of conventional mass flow devices into a unique compact design

More information

Climatic Independent Level Sensor LAR

Climatic Independent Level Sensor LAR 3 JAHRE GEWÄHRLEISTUNG SENSORS FOR FOOD AND BIOPHARMA. Product Information LAR-361 LAR-761 FOOD Climatic Independent Level Sensor LAR Application / Specified usage Hydrostatic level measurement in humid

More information

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765 Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765 Application Single-acting positioner for attachment to pneumatic control valves. Supplied with either an electric input signal from

More information

ATM.1ST. Pressure transmitters CUSTOMER BENEFITS

ATM.1ST. Pressure transmitters CUSTOMER BENEFITS Pressure transmitters ATM.1ST CUSTOMER BENEFITS High precision pressure sensor over the whole temperature range Electronic compensation Modular sensor structure (any process and electrical connections

More information

INDUSTRIAL. Pressure Transmitters. Product Guide. Low cost to high accuracy portfolio. Ranges from 70 mbar to 1400 bar. Flexible, rugged and reliable

INDUSTRIAL. Pressure Transmitters. Product Guide. Low cost to high accuracy portfolio. Ranges from 70 mbar to 1400 bar. Flexible, rugged and reliable INDUSTRIAL Pressure Transmitters Product Guide Low cost to high accuracy portfolio Ranges from 70 mbar to 1400 bar Flexible, rugged and reliable Fixed and rangeable 4-20mA outputs Electrical/pressure connection

More information

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in: XMO2 Panametrics Smart Oxygen Analyzer Applications An oxygen transmitter for use in: Inerting/blanketing liquid storage tanks Reactor feed gases Centrifuge gases Catalyst regeneration Solvent recovery

More information

Measurement of Low GAS & Liquid Flows

Measurement of Low GAS & Liquid Flows Measurement of Low GAS & Liquid Flows The Measurement Measurement with a float in a tapered borosilicate glass tube. Series 2100 with a 100 mm flow tube Series 2150 with a 150 mm flow tube Series 2300

More information

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE ATEX CHEMISTRY DIAPHRAGM PUMPS. ATEX VARIO CHEMISTRY DIAPHRAGM PUMPS. Chemistry diaphragm pumps, vacuum systems and gauges for use in

More information

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.:

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.: Smart level probe type APC-2000ALW/L Programmable zero shift, range and damping ratio 4...20 ma output signal + HART protocol Accuracy 0,16% Local display Intrinsic safety certificate (ATEX, IECEx) II

More information

Proportional pressure regulators VPPE

Proportional pressure regulators VPPE Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/

More information

VG5 Supplementary instructions

VG5 Supplementary instructions VG5 Supplementary instructions 2-wire / 10 GHz Radar (FMCW) Level Meter Supplementary Instructions for ATEX applications HYCONTROL CONTENTS VG5 1 General safety information 4 1.1 Scope of the document...

More information

Differenz-Drucktransmitter Differential pressure transmitter Transmetteur de pression différentielle bar

Differenz-Drucktransmitter Differential pressure transmitter Transmetteur de pression différentielle bar 692 Differenz-Drucktransmitter Differential pressure transmitter Transmetteur de pression différentielle 0 0.1 25 bar E Technical overview The differential pressure transmitter of type series 692 with

More information

2600T Series Pressure Transmitter

2600T Series Pressure Transmitter Data Sheet 2600T Series Pressure Transmitter Model 261GC/GG/GJ/GM/GN Gauge Model 261AC/AG/AJ/AM/AN Absolute with direct mount seal Base accuracy: ±0.15 % Span limits 0.3 to 60000kPa; 1.2inH 2 O to 8700psi

More information