1 DF- Inch Gas Train 0/0/0
2 -/" Quick Seal -/" x " Nipple -/" 0 Elbow -/" x -/" Nipple -/" Union -/" x -/" x /" Tee 7 N/A N/A -/" KAT Solenoid Valve -/" V0A007 Hydraulic Actuator and V0A00 Valve 0 Maxitrol -/" MRD Modulating Valve /" Male x /" Female Reducer -/" Manual Ball Valve -/" x 0" Nipple 0-" w.c. or 0- psi or 0- psi Pressure Gauge (check spec) -- w.c. Gas Pressure Gauge -/" Female x " Male Adapter 7 " Dual Fuel Midco Burner N/A N/A N/A N/A 0 /" Brass Elbow /" Male x /" Female Reducer -x/ Pilot Gas Regulator /" 0 Elbow /" Close Nipple (-/") /" x " Nipple /" Pilot Shut Off Valve /" Male x /" Female Reducer /" x " Nipple Pyroseal Furnace Cement (AX # 0) 0 -/" x 7-/" Nipple -/" x " Nipple -/" x " Nipple 0 / U-Bolt, washer, and locknuts ( Places) / Bolt, washer, and locknuts ( Places) M07HM Bracket Places / x / Self Tapping Sheet Metal Screws PLaces Burners Riveted together with /" rivets. Inlet Pressure: 7 in. w.c. - psi. Max. Natural Gas Manifold Pressure: in. w.c. Max. LP Manifold Pressure:. in. w.c. gas pressure exceeds psi.: P/N = ---.-OR--0 ( psi. max.) Item # is replaced by V0D0 and V0C0 Item # (x) Standard Gas Train 7 0 /" 0 Low Fire By-Pass Pilot Regulator Pilot Tap 0 Drawing Name: DF inch Gas Train Parent Assembly: DF Sheet: of Fractions: / Decimal:.XX.0.XXX.0 Angles:
3 -/" Quick Seal -/" x " Nipple -/" 0 Elbow -/" x -/" Nipple 0 -/" Union -/" x -/" x /" Tee 7 /" Square Head Pipe Plug -/" KAT Solenoid Valve -/" V0A007 Hydraulic Actuator and V0A00 Valve 0 Maxitrol -/" MRD Modulating Valve /" Male x /" Female Reducer -/" Manual Ball Valve -/" x 0" Nipple N/A N/A N/A N/A -/" Female x " Male Adapter 7 " Dual Fuel Midco Burner /" x " Nipple /" x /" x /" Tee 0 /" Brass Elbow /" Male x /" Female Reducer -x/ Pilot Gas Regulator /" 0 Elbow /" Close Nipple (-/") /" x " Nipple /" Pilot Shut Off Valve /" Male x /" Female Reducer /" x " Nipple Optional Antunes HGP-A M Pressure Sw itch 0 Optional Antunes LGP-A M Pressure Sw itch Pyroseal Furnace Cement (AX # 0) -/" x 7-/" Nipple -/" x " Nipple -/" x " Nipple 0 / U-Bolt, washer, and locknuts ( Places) / Bolt, washer, and locknuts ( Places) M07HM Bracket Places / x / Self Tapping Sheet Metal Screws PLaces Burners Riveted together with /" rivets. Inlet Pressure: 7 in. w.c. - psi. Max. Natural Gas Manifold Pressure: in. w.c. Max. LP Manifold Pressure:. in. w.c. gas pressure exceeds psi.: P/N = ---.-OR--0 ( psi. max.) Item # is replaced by V0D0 and V0C0 Item # Drawing Name: DF inch Gas Train Parent Assembly: DF Sheet: of Gas Train w/press. Switch (x) (x) Pilot Regulator (x) 7 (x) (x) 0 0 Fractions: / Decimal:.XX.0.XXX.0 Angles: 0 Pilot Tap /" Low Fire By-Pass Location of Additional Pipe with Gas Pressure Gauge if Requested.
4 -/" Quick Seal -/" x " Nipple -/" 0 Elbow -/" x -/" Nipple 0 -/" Union -/" x -/" x /" Tee 7 0-" w.c. or 0- psi or 0- psi Pressure Gauge (check spec) /" Tee -/" V0A007 Hydraulic Actuator and V0A00 Valve 0 Maxitrol -/" MRD Modulating Valve /" Male x /" Female Reducer -/" Manual Ball Valve -/" x 0" Nipple -x/ Pilot Gas Regulator V0C0 Solenoid -/" Female x " Male Adapter 7 " Dual Fuel Midco Burner N/A N/A -/" KAT Solenoid Valve 0 /" Brass Elbow /" Male x /" Female Reducer /" Close Nipple N/A N/A /" Close Nipple (-/") /" x -/" Nipple /" Manual Ball Valve /" Male x /" Female Reducer /" Plug Pyroseal Furnace Cement (AX # 0) 0 -/" x 7-/" Nipple -/" x " Nipple -- w.c. Gas Pressure Gauge -/" x " Nipple /" x " Nipple Gas Train w/upstream Pilot Burners Riveted together with /" rivets. Item # 7 0 /" 0 Inlet Pressure: 7 in. w.c. - psi. Max. Natural Gas Manifold Pressure: in. w.c. Max. LP Manifold Pressure:. in. w.c. 7 0 gas pressure exceeds psi.: P/N = ---.-OR--0 ( psi. max.) Item # is replaced by V0D0 and V0C0 Drawing Name: DF inch Gas Train DDH Parent Assembly: DF Sheet: of Fractions: / Decimal:.XX.0.XXX.0 Angles: Low Fire By-Pass
5 -/" Quick Seal -/" x " Nipple -/" 0 Elbow -/" x -/" Nipple -/" Union -/" x -/" x /" Tee 7 0-" w.c. or 0- psi or 0- psi Pressure Gauge (check spec) /" Tee -/" V0A007 Hydraulic Actuator and V0A00 Valve 0 Maxitrol -/" MRD Modulating Valve /" Male x /" Female Reducer -/" Manual Ball Valve -/" x 0" Nipple -x/ Pilot Gas Regulator V0C0 Solenoid -/" Female x " Male Adapter 7 " Dual Fuel Midco Burner N/A N/A -/" KAT Solenoid Valve 0 /" Brass Elbow /" Male x /" Female Reducer /" Close Nipple /" 0 Elbow /" Close Nipple (-/") /" x " Nipple /" Manual Ball Valve /" Male x /" Female Reducer /" Plug Pyroseal Furnace Cement (AX # 0) 0 -/" x 7-/" Nipple -/" x " Nipple -- w.c. Gas Pressure Gauge -/" x " Nipple Optional Antunes HGP-A M Pressure Sw itch Optional Antunes LGP-A M Pressure Sw itch Inlet Pressure: 7 in. w.c. - psi. Max. Natural Gas Manifold Pressure: in. w.c. Max. LP Manifold Pressure:. in. w.c. gas pressure exceeds psi.: P/N = ---.-OR--0 ( psi. max.) Item # is replaced by V0D0 and V0C0 Gas Train Upstream Pilot w/ Pressure Switches Burners Riveted together with /" rivets. Item # built in house Drawing Name: DF inch Gas Train Parent Assembly: DF Sheet: of 7 Fractions: / Decimal:.XX.0.XXX.0 Angles: /" 0 Low Fire By-Pass 0 7 0
LGB Series 1 & 2 Section And Base Assembly
LGB Series 1 & 2 Section And Base Assembly Current Service Parts 263 LGB Series 1 & 2 Section And Base Assembly Fig. Part Size Description 383-300-405 Section replacement kit, Includes seals, rope and
More informationGAS VALVE RETROFIT KIT Pull Through Tube Heater Models
GAS VALVE RETROFIT KIT Pull Through Tube Heater Models DESCRIPTION: This kit is designed to replace existing Honeywell gas valves #VR8205P and #VR8205Q with White-Rodgers gas valves #36J23 and #36J58 respectively
More informationGM Series Dual-Block Multi-Function Gas Control Valves
Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin GM Issue Date 0297 GM Series Dual-Block Multi-Function Gas Control Valves Figure 1: GM Series
More informationACCESSORY KIT INSTALLATION INSTRUCTIONS
ACCESSORY KIT INSTALLATION INSTRUCTIONS 1NP0680 - PROPANE CONVERSION FOR USE WITH MODELS: PM8, PC8, PM9, PC9, FL9M, FL9C, FC9M, FC9C This conversion kit is to be installed by a qualified service agency
More informationINSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235)
P/N 126905-01 Rev. B 11/2016 INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235) For All Single, Dual and Triple Burner Natural and Propane/LP Gas Logs P126905-01 For
More informationSV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT. SV/614 Series SV-DLE/614 Series
SV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT SV/614 Series SV-DLE/614 Series Normally closed automatic shutoff valve with proof of closure and the following approvals. CSA Certified
More informationCO2 Tank Conversion Kit P.N , P.N , and P.N
Foodservice Group Multiplex Beverage Equipment Installation Instructions for CO2 Tank Conversion Kit P.N. 002247, P.N. 0022505, and P.N. 0025099 Introduction The following instructions cover the installation
More informationInstallation Instructions
48011HW NATURAL GAS TO PROPANE CONVERSION KIT 58HDX, 359AAV, PG9YAB, PG9YAA Installation Instructions SAFETY REQUIREMENTS Installing and servicing heating equipment can be hazardous due to gas and electrical
More information299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012
Installation Guide English September 2012 299H Series Introduction This Installation Guide provides instructions for installation, startup, and adjustment of 299H Series regulators. To receive a copy of
More informationFOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM
IMI CORNELIUS INC One Cornelius Place Anoka, MN 55303-623 Telephone (800) 238-3600 Facsimile (612) 22-326 INSTALLATION INSTRUCTIONS FOR INSTALLING CO 2 BLENDER KIT (P/N 111612000 IN BEER SYSTEM SECONDARY
More informationG196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve
Installation Instructions Issue Date August 19, 2008 G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Application The G196 valves are suitable for use with natural gas, Liquefied
More informationDual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series
Dual Modular Safety Shutoff Valves DMV-D/602 Series DMV-DLE/602 Series Two normally closed safety shutoff valves in one housing; each with the following approvals. UL Recognized UL 429 File # MH16727 CSA
More informationPressure Dump Valve Service Kit for Series 2300 Units
Instruction Sheet Pressure Dump Valve Service Kit for Series 00 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00 applicator tanks when the unit
More informationG196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve
Installation Instructions Issue Date March 13, 2013 G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Application The G196 valves are suitable for use with natural gas, Liquefied
More informationGas Conversion Kits Push Through (Positive Pressure) Tube Heater Models
DESCRIPTION These kits are designed to convert from one gas type to another (eg. from NATURAL to PROPANE or from PROPANE to NATURAL) when equipped with White-Rodgers DSI gas valves number 36J23 or 36J58.
More informationDual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series
Dual Modular Safety Shutoff Valves DMV-D/602 Series DMV-DLE/602 Series Two normally closed safety shutoff valves in one housing; each with the following approvals. UL Recognized UL 429 File # MH16727 CSA
More informationTANK MATE INCLUDES: TOOLS REQUIRED: CONRADER VALVES 3/4 WRENCH **TUBING CUTTERS TEE PETCOCK TEE ASSEMBLY 8 FOOT NYLON TUBING
CONRADER VALVES TANK MATE AUTOMATIC DRAIN VALVE INSTALLATION KIT INCLUDES: TEE PETCOCK TEE ASSEMBLY 8 FOOT NYLON TUBING WV-1 DRAIN VALVE TOOLS REQUIRED: 3/4 WRENCH **TUBING CUTTERS ** NEEDED TO CUT METAL
More informationV5197A. Firing Rate Gas Valve APPLICATION FEATURES PRODUCT HANDBOOK
V5197A Firing Rate Gas Valve PRODUCT HANDBOOK APPLICATION The V5197A are firing rate valves used to provide variable flow control of air, natural gas, liquefied petroleum (LP), and manufactured gases.
More informationDual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series
Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure DMV-D/624L Series DMV-DLE/624L Series Two normally closed automatic shutoff valves in one housing. Valve 2 (V2) incorporates proof
More informationLP GAS PRODUCTS HIGH QUALITY GAS PRODUCTS SINCE 1957
LP GAS PRODUCTS HIGH QUALITY GAS PRODUCTS SINCE 1957 Enerco, based in Cleveland Ohio, has been at the forefront of infrared technology since 1957. This market leading technology has allowed Enerco to build
More informationDual Modular Safety Shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634
Dual Modular Safety Shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634 Two normally closed automatic shutoff valves in one housing.
More informationPART NO. UPC DESCRIPTION QTY LBS
24 Iron Pipe Fittings Product Applications For use with brass, copper or iron pipe. Designed for low and medium pressure pipe line connections. Typically used in water, grease, fuels, LP and natural gas,
More informationOperating Instructions Models and Hydrostatic Test Pumps
Operating Instructions Models 36454 and 364540 Hydrostatic Test Pumps 36454 DIMENSIONS: 24 (61cm) L x 19 (48cm) W x 19.5 (50cm) H WEIGHT: 135 lbs 61.5 kg PUMP: Twin piston: Positive displacement type Inlet
More informationDual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series
Dual Modular Safety Shutoff Valves with Two-stage operation DMV-ZRD/602 Series DMV-ZRDLE/602 Series Two normally closed automatic shutoff valves in one housing; each with the following approvals. UL Recognized
More informationG96 Series BASOTROL Dual Operator Valve
Installation Instructions 9. Issue Date February 22, 2013 G96 Series BASOTROL Dual Operator Valve Applications The G96 valves are combination, dual operator, automatic valves available with or without
More informationVG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators
VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators Technical Instructions Document No. 155-51P5 VG August 11, 005 GAS009R1 VGG VGD0 VGD0 Description Only when assembled to SKP
More informationDual Modular Safety shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634
Dual Modular Safety shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634 Two normally closed automatic shutoff valves in one housing.
More informationCATALOG OF REPLACEMENT PARTS
CATALOG OF REPLACEMENT PARTS 00RX AND MSA HEAVY DUTY GAS GRIDDLES MODELS RX RX RX 0RX RX RX MSA MSA MSA MSA0 MSA MSA For additional information on Vulcan or to locate an authorized parts and service provider
More informationType ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002
Installation Guide English May 2002 Type ACE97 Introduction This installation guide provides instructions for installation, startup, and adjustment. To receive a copy of the instruction manual, contact
More informationOperating Instructions Models and Hydrostatic Test Pumps
Operating Instructions Models 46453 and 464530 Hydrostatic Test Pumps 46453 DIMENSIONS: 27 (67.5cm) L x 22 (55cm) W x 34 (85cm) H WEIGHT: 160 lbs. 73 kg PUMP: Twin piston: Positive displacement type Inlet
More informationDual Solenoid Gas Valve Installation
Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing or servicing FLYNN Gas Products. Carefully follow all instructions in this bulletin and all instructions
More informationPressure Dump Valve Service Kit for Series 3000 Units
Instruction Sheet Pressure Dump Valve Service Kit for Series 000 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00, 400, 500, and 700 applicator
More informationSPECIFICATIONS ATTENTION
VPS 504 S06 Installation Manual - P/N 80122 - Ed. 01/09 VPS 504 S06 and S05 Valve Proving System Installation Instructions VPS 1 6 Gases Natural gas, air and other inert gases. NOT suitable for butane
More informationGM-7000 Series CE Approved Gas Control Valve
Installation Instructions GM-7000 Issue Date November 9, 2012 GM-7000 Series CE Approved Gas Control Valve Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing
More informationUL Listed GM-20/25 and GM-40/45 Series Dual-block Multi-function Gas Control Valves
Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin GM-20/25 GM-40/45 Issue Date 1298 UL Listed GM-20/25 and GM-40/45 Series Dual-block Multi-function
More informationSPECIFICATIONS. Normally closed automatic shutoff valve with proof of closure. Fast opening, fast closing. ATTENTION
SV/614 Installation Manual -P/N 80128 - Ed. 01/08 SV-(DLE) 10../614 Safety Shutoff Valve with Proof of Closure Installation Instructions 1 6 SV/614 SV-DLE/614 SPECIFICATIONS Normally closed automatic shutoff
More informationSKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function
SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function Technical Instructions Document No. 155-752 SKP25 U.. Description Only when assembled to Series VG Gas valves SKP25
More informationOperating Instructions Models and Hydrostatic Test Pumps
Operating Instructions Models 33100 and 33101 Hydrostatic Test Pumps 33100 DIMENSIONS: WEIGHT: PUMP: MOTOR: CONTROL: GAUGE: DISCHARGE HOSE: 16 (40cm) L x 22 (55cm) W x 18 (45cm) H 87 lbs., 39.5 kg Triplex
More informationDual Modular Safety Shutoff Valves. DMV-D/11 Series DMV-DLE/11 Series
Dual Modular Safety Shutoff Valves DMV-D/11 Series DMV-DLE/11 Series Two normally closed safety shutoff valves in one housing; each with the following approvals. CSA Certified ANSI Z21.21 CSA 6.5 Marked
More informationInstallation Instructions
LP and High Altitude LP Gas Conversion Kit For United States Installations Installation Instructions For Model Series *G6/PGF1 Furnaces, *L1/PGC1 Furnaces, and *R4/PPG1 Gas/Electric Appliances using Honeywell
More informationLARGE DRY CHEMICAL, TWIN-AGENT, AFFF, HALON 1211, AND AQUASONIC (NITROGEN-OPERATED SYSTEMS) Pressure Regulator Test Manual
LARGE DRY CHEMICAL, TWIN-AGENT, AFFF, HALON 1211, AND AQUASONIC (NITROGEN-OPERATED SYSTEMS) Pressure Regulator Test Manual 002694 IntroductIon 8-1-11 Page 1 ForEWord This manual is intended for use with
More information36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve
Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION
More informationModels 106-RF / 206-RF Rate of Flow Control Valve
Rate of Valve KEY FEATURES Accurately limits low to a pre-set maximum Easily adjustable low limit Paddle-style oriice plate included Optional oriice plate housing 106-RF Globe Product Overview The 106-RF
More informationModulating Valves for Atmospheric, Infrared, and Direct Fired Burners
BULLETIN MT2035-07/05 Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners M/MR Series M411, M511, M611 M420, M520, M620, MR410, MR510, MR610 MR212D, MR212E, MR212G and MR212J (Flanged),
More informationRESIDENTIAL - IRRIGATION - WATER TREATMENT OF FLORIDA PUMP PROTECTION - EFFICIENCY - ENERGY SAVER - COMFORT
OF FLORIDA Pressure Gauge Dry Pressure gauge DRY Steel casing Lower mount PG060L20D4M 1/4" LOWER MOUNT METAL 2" 0-60 PSI 100 0.21 PG100L20D4M 1/4" LOWER MOUNT METAL 2" 0-100 PSI 100 0.21 Pressure gauge
More informationBGA158 Series CE Approved Class B Shutoff Gas Valve
Installation Instructions BGA158 Issue Date March 22, 2016 BGA158 Series CE Approved Class B Shutoff Gas Valve Applications The BGA158 Series shutoff gas valve is an electrically operated shutoff valve
More informationDual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series
Dual Modular Safety Shutoff Valves with Two-stage operation DMV-ZRD/602 Series DMV-ZRDLE/602 Series Two normally closed automatic shutoff valves in one housing; each with the following approvals. UL Recognized
More informationDual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series
Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure DMV-D/624L Series DMV-DLE/624L Series Two normally closed automatic shutoff valves in one housing. Valve 2 (V2) incorporates proof
More informationMWEA MAINTENANCE SEMINAR SPECIALTY VALVES POWER GLOBES
MWEA MAINTENANCE SEMINAR SPECIALTY VALVES POWER GLOBES J O H N G. H U N T E R Types of Valves P A U L M A R C H I Accessories Principals of Operation Maintenance Control Valve Types Common Problems Key
More information/2004 US/CA
630 9765 0/004 US/CA For the contractor Propane Conversion Kit Instructions Sealed Combustion Gas Boiler Logano GA44 This kit and instructions are for converting the GA44 model boilers from Natural Gas
More informationInstruction Manual VCG-6
Specifications Amps / Volts requirements 400 ma @ 24 VDC Propane pressure (VCG-6LP) 11 WC / 2.8 kpa Natural Gas pressure (VCG-6NG) 4.5 WC / 1.15 kpa Cu ft per hour / CO2 3-6 SCFH BTU Rating (Variable)
More informationDual Modular Safety Shutoff Valve with NEMA 4x Enclosure. DMV-D/604L Series DMV-DLE/604L Series
Dual Modular Safety Shutoff Valve with NEMA 4x Enclosure DMV-D/604L Series DMV-DLE/604L Series Two normally closed automatic shutoff valves in one housing; each with the following approvals. UL Listed
More informationDual Modular Safety Shutoff Valves with NEMA 4x Enclosure DMV-D 704/604 DMV-DLE 704/604
Dual Modular Safety Shutoff Valves with NEMA 4x Enclosure DMV-D 704/604 DMV-DLE 704/604 Two normally closed safety shutoff valves in one housing; each with the following approval. CSA Certified ANSI Z21.21
More information36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS
36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING
More informationOperator: Save these instructions for future use!
INLET PRESS TAP WHITE-RODGERS 36E93-304 Delay-Opening Combination Gas Valve INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
More informationYour safety and the safety of others are very important.
NATURAL GAS TO PROPANE CONVERSION KIT ALPKT57- INSTALLATION INSTRUCTIONS PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements... Table of Contents INSTALLATION
More informationSKYBOX USER GUIDE EMERGENCY ULTRAFILTRATION PACKAGE. The trusted choice for rapid response potable water solu4ons SKYBOX
SKYBOX EMERGENCY PACKAGE USER GUIDE SKYBOX EMERGENCY PACKAGE EMERGENCY UNIT The trusted choice for rapid response potable water solu4ons www.skyjuice.org.au SKYBOX EMERGENCY FILTRATION PACKAGE The SKYBOX
More informationBGA158 Series CE Approved Class A Shutoff Gas Valve
Installation Instructions BGA158 Issue Date August 24, 2011 BGA158 Series CE Approved Class A Shutoff Gas Valve Applications The BGA158 Series shutoff gas valve is an electrically operated gas valve that
More informationPropane Conversion Kit Instructions
604 8 0/ US/CA For heating engineers Propane Conversion Kit Instructions Logano G4 X gas-fired boiler This conversion kit and the accompanying instructions are for conversion of G4 X gas-fired boilers
More informationGS-20/25 and GS-40/45 Series Single-block Multi-function Gas Control Valves
Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin GS-20/25 GS-40/45 Issue Date 1298 GS-20/25 and GS-40/45 Series Single-block Multi-function Gas
More informationRAYPAK ILLUSTRATED PARTS LIST
COMMERCIAL MODELS: XFYRE 300 THROUGH 850 CATALOG NO. 9300.79 Effective: 10-05-18 Replaces: 09-15-17 RAYPAK ILLUSTRATED PARTS LIST MODEL SIZES: 300, 400, 500, 700 & 850 MODEL TYPES: MODULATING CONDENSING
More informationStandard Specifications
NARM, 2 Ways of Connection Small Size Pressure Gauge ø5mm Reverse flow function available on the standard model Space Saving -B2 NARM-6A-NG Standard Specifications Fluid Proof pressure psig (MPa) Max.
More informationV5097A-E Industrial Gas Valves
V097A-E Industrial Gas Valves PRODUCT DATA FEATURES APPLICATION The V097A-E Gas Valves are used with the V40, V40 and V90 Fluid Power Actuators to control gas flow to commercial and industrial burners.
More informationDual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11
Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11 Two normally closed safety shutoff valves in one housing; each with the following approvals. CSA Certified ANSI Z21.21 CSA 6.5 Marked C/I
More informationVG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators
VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators Technical Instructions Document No. 155-51P5 VG August 1, 01 VGG VGD0 VGD0 Description Only when assembled to Series SKP actuators
More informationHPIC D Hydrostatic Test Pump PRODUCT INFORMATION AND OPERATING INSTRUCTIONS
WIDDER TOOLS HPIC-10000-D Hydrostatic Test Pump PRODUCT INFORMATION AND OPERATING INSTRUCTIONS Description: The WIDDER Hydrostatic Test Systems C Series is a portable, selfcontained, air driven hydrostatic
More informationButterfly Control Valve. DMK/6 Series
Butterfly Control Valve DMK/6 Series UL Listed for US and Canada UL 842 and ULc C125 & C842 File # MH 18741 Models DMK 707/6 (3/4 NPT) DMK 710/6 (1 NPT) DMK 712/6 (1 1/4 NPT) DMK 715/6 (1 1/2 NPT) DMK
More informationGas Conversion Kits CERAMIC HEATER SERIES (1, 2, 3, 4 Burner Units)
DESCRIPTION These kits are designed to convert from one gas type to another (eg. from NATURAL to PROPANE or from PROPANE to NATURAL) only for new heaters (5 years or newer) by replacing the gas valve spring
More informationDual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure. DMV-ZRD/612 Series DMV-ZRDLE/612 Series
Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure DMV-ZRD/612 Series DMV-ZRDLE/612 Series Two normally closed automatic shutoff valves in one housing. Valve 1 (V1) incorporates
More informationDual Modular Safety Shutoff Valves with Proof of Closure. DMV-D/622 Series DMV-DLE/622 Series
Dual Modular Safety Shutoff Valves with Proof of Closure DMV-D/622 Series DMV-DLE/622 Series Two normally closed automatic shutoff valves in one housing. Valve 2 (V2) incorporates proof of closure. Each
More informationGAS SUPPLY DESIGN GUIDE
GAS SUPPLY DESIGN GUIDE Natural Gas, Propane Gas, or Dual Fuel Fired Modulating, Condensing Boilers BENCHMARK Series Gas-Fired Boilers For models: BMK750 to BMK6000 Last Update: 06/20/2014 PR1 06/20/14
More informationNatural Gas High-Altitude Conversion Kit For Installations in the United States (2,001 10,000 Feet)
Natural Gas High-Altitude Conversion Kit For Installations in the United States (2,001 10,000 Feet) INSTALLATION INSTRUCTIONS For R7 Series Light Commercial Packaged Gas Electric Units IIMPORTANT: Please
More information36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS
INLET PRESS TAP WHITE-RODGERS 36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS
More informationGas Conversion Kit Pilot Ignition Heaters
INSTALLATION INSTRUCTIONS Gas Conversion Kit Pilot Ignition Heaters View these instructions online at www.lbwhite.com Kit Contents: DESCRIPTION QTY. Instructions 1 Burner Orifi ce 1 Pilot Orifi ce 1 Variable
More informationOperating Instructions Models 36200, , 46200, Hydrostatic Test Pumps
Operating Instructions Models 36200, 362000, 46200, 462000 Hydrostatic Test Pumps 46200 DIMENSIONS: 28 (70cm) L x 24 (60cm) W x 38 (87.5cm) H WEIGHT: PUMP: ENGINE: CONTROL: GAUGE: DISCHARGE HOSE: INTAKE
More informationBGA158, BGA171 and BGA110 Series Shutoff Gas Valve
Installation Instructions BGA Series Issue Date October 3, 2017 BGA158, BGA171 and BGA110 Series Shutoff Gas Valve Applications The BGA Series shutoff gas valve is an electrically operated gas valve that
More informationVOLUMATIC WATER REGULATOR
VOLUMATIC WATER REGULATOR For Cage Systems - PDS and Manual Adjustment Part Number 00-, 00-, 00- Introduction The Chore-Time VOLUMATIC Water Regulator is designed to regulate the water pressure for the
More informationNatural Gas to L.P. Gas Conversion Kit
Natural Gas to L.P. Gas Conversion Kit For Bosch 80% AFUE Gas Furnace, BGS80 Model Installation Instructions 3124627 2 Natural Gas to L.P. Gas Conversion Kit Installation Instructions Data subject to change
More informationBGC258 Series BASOTROL Gas Valve
Installation Instructions BGC258 Issue Date September 6, 2017 BGC258 Series BASOTROL Gas Valve Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing or servicing
More informationConversion instructions from natural gas to propane
6 720 804 895 202/0 EN-US For heating engineers Conversion instructions from natural gas to propane Room air-independent special gas-fired boiler Logano GA24 This conversion kit and the instructions are
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Propane Gas Conversion Kit WGCK-1 Instructions for 0-6,000 Feet Elevation Installations This propane gas conversion kit is to be used only when converting the following furnace
More informationUSER GUIDE EMERGENCY PUMP KIT ULTRAFILTRATION ULTRAFILTRATION SYSTEMS. safe drinking water ULTRAFILTRATION UNIT FOR USE WITH:
EMERGENCY ULTRAFILTRATION PUMP KIT USER GUIDE FOR USE WITH: ULTRAFILTRATION UNIT safe drinking water ULTRAFILTRATION SYSTEMS www.aquasolutions.com.au info@aquasolutions.com.au EMERGENCY PUMP KIT The emergency
More informationinstallation instructions
installation instructions GAS CONVERSION KIT PROPANE-TO-NATURAL P/N 315572-71201 4GAD 6GAD Cancels: IIK 4G-50-4 IIK 4G-50-5 7/15/91 NOTE: Read the entire instructions before starting the installation.
More informationCrest Heating Boilers FBN(L) Series &
Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 877-554-5544 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Crest Heating Boilers FBN(L) 751-2001 Series 100-101 & 110-111
More information299H Series Pressure Reducing Regulators
Instruction Manual Form 5497 299H Series January 2014 299H Series Pressure Reducing Regulators! WARNING Failure to follow these instructions or to properly install and maintain this equipment could result
More informationRED DOT UNITS 72R SERIES. Controls. Water & Air PAGE 271
RED DOT UNITS Controls Water & Air PAGE 271 AIR SWITCHES AND CYLINDERS 72R000 Normally Closed, Opens at 2 PSIG 1 8-27 NPTF Male AIR SENSING SWITCHES RD--447-0P 72R0070 Normally Open, Closes at 21 TO 29
More informationBERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features
Level Control Valve with Altitude Pilot High level reservoirs & water towers Energy cost critical systems Systems with poor water quality Inherent refreshing Level sustaining at reservoir outlet The Level
More information36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS
INLET PRESS TAP WTE-RODGERS 36E54-214 DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS
More informationPressure Independent Control Series
Document No. 155-522 Pressure Independent Control Series Two-Way Cast Iron Flanged Bodies, ANSI 125 and 250 Description Siemens Pressure Independent Control Valves integrate three functions into a single
More informationAKIT1901LM (Metal levers) AKIT1901XM (Cross Handles)
PALLADIAN EXPOSED TUB SET WITH HANDSHOWER AKIT1901LM (Metal levers) AKIT1901XM (Cross Handles) COLORS/FINISHES WARRANTY FEATURES Palladian metal levers or cross handles Floor mounted exposed two handle
More informationCM MBC & CM MBC PARTS LIST
8650 Enterprise Drive, Peosta IA 52068 319-556-7484 / Fax 319-556-1235 CM-1500-0MBC & CM-1503-1MBC Engine Oil Grade: Engine Oil Capacity: Pump Oil Grade: Pump Oil Capacity: Nozzle Size: PARTS LIST (After
More information36H SERIES Combination Gas Valve
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION The 36H series combination gas valve is
More informationTECHNICAL DATA. TRIMPAC Model B-5 & B-5B
September 16, 2013 Trimpac 250a 1. DESCRIPTION DEsCRIPTIoN is a factory assembled trim package for a ed an electric/pneumatic release module in a metal enclosure. The standard trim normally required on
More informationDual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11
Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11 Two normally closed safety shutoff valves in one housing; each with the following approvals. CSA Certified ANSI Z21.21 CSA 6.5 Marked C/I
More informationSlam Shut Valves SCN
Slam Shut Valves SCN SCN > Slam shut valves Introduction SCN is a compact safety device (SAV) which quickly intercept gas flow whenever the pressure under monitoring reaches a pre-set limits, or whenever
More informationM/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners
M/MR Modulating Valves design certified For Atmospheric, Infrared, and Direct Fired urners TALE OF CONTENTS Description/Specifications... 1 Introduction... 2 Direct Fired Applications (Negative Pressure)...
More informationRED DOT UNITS 72R SERIES. Controls. Water & Air PAGE 343
RED DOT UNITS Controls Water & Air PAGE 343 AIR SWITCHES AND CYLINDERS 72R000 Normally Closed, Opens at 2 PSIG 1 8-27 NPTF Male AIR SENSING SWITCHES RD--447-0P 72R0070 Normally Open, Closes at 21 TO 29
More informationFITTINGS THREAD LUBRICANTS. Fittings 20,000 PSI
Jetstream offers a wide variety of fittings with various connection types to fit your 20,000 psi application needs. The standard connection types, Type M, MP, and MP Tube lance, are available in standard
More informationUnderground irrigation
Prograers Turbines and Pop-ups Solenoid valves ittings Accessories and Hoses 70 Irrigation located in set areas, and the only time that you need to invest into it, is the time it takes to set it up, then
More informationPortable Abrasive Blast Cleaning Machines 2452/2040/1440/1028
Page 1 of 8 Hodge Clemco Ltd Portable Abrasive Blast Cleaning Machines 2452/2040/1440/1028 Parts Identification Owner s Manual Date of Issue: 01.01.03 TS.OM 267 Hodge Clemco Ltd Orgreave Drive Sheffield
More information