TURNKEY PROPOSAL FOR SNG SYSTEM RANSOME RW900E WATERBATH VAPORIZER WITH MPM50C MIXER

Size: px
Start display at page:

Download "TURNKEY PROPOSAL FOR SNG SYSTEM RANSOME RW900E WATERBATH VAPORIZER WITH MPM50C MIXER"

Transcription

1 Date: October 8, 2015 TEE/RM/P&G/15-10/V7-I TURNKEY PROPOSAL FOR SNG SYSTEM RANSOME RW900E WATERBATH VAPORIZER WITH MPM50C MIXER For: P&G Pakistan Contact Person: Ms. Nihal Hashish / Mr. Hur Raza Ihsan / Mr. Umer Ali Khan Application: NG Back-up Location: Port Qasim- Karachi Temperate: Range is 0º C to 50º C Design Basis: NFPA 58, NEMA, FM, ASME, MIGS 2010 LPG Flow: ±52 MMBTU/Hr Send-out Pressure: ±8 psig. LPG Composition: 60% Propane - 40% Butane Electric Tension 220 \ 380V \ 50HZ Validity: 16 days from date

2 Reference Max. NG Load per the Gas Utility consumption: approx. 52mmbtu/hr Recommendation For Consumption based on Equipment Details & Gas Requirement: RW900(E) Gas Fired Waterbath LPG vaporizer and MPM50(C) MPM Air Mixer/Blender Vaporizer Feed Pump (LPG supply pump skid) Truck transport unloading station (Decanting pump skid) One year recommended spares LPG Leak Detection system Fire Detection System Electro-static Discharge System

3 PICTORIAL PRESENTATION Comprehensive View Complete System

4 Techno - Commercial Offer Import Specifications with DISCOUNT No. Item Description Quantity Price (USD) A RANSOME RW 900 E (Gas Fired Waterbath LPG Vaporizer) 1 package $ 41,490 Cap: mmbtu/hr or 1725kg/hr * Gas Fired Waterbath/indirect fired vaporizer. ASME, FM Approved, NFPA 58 Conformance *Features, Control and Safety Interlock. Hi Water Temperature Limit Hi LPG Liquid Level Control/Solid State Sensor & Relay SOR 1 with Inlet Solenoid Circulating pump Lo Water Level Shut Down Water Tempt 175 F Heavy Steel Gauge Replaceable combustion Vent Painted with Hi Heat Paint Black Burner rings: Venturi Type Pressure Vessels & most control components are enclosed in heavy steel cabinetry Inlet includes Y strainer and pressure balancing bypass piping assembly Inlet: 1 FNPT. Outlet: 2 MNPT Electric Pilot Re-ignitor; Protects against pilot outage due to unusually turbulent winds and eliminates need to manual start vaporizer. 110v required. B RANSOME MPM 50 C (Modulating Proportional Air Mixer/Blender) 1 package $ 67,135 Exp: Class 1 Group D Div 2. Modulating Proportioning Mixer with ABB C control module Capacity: mmbtu/hr (SNG) Will mix LPG & Air at any proportions/per NG Wobbe and Raw Gas. FM Approved / (Double NEMA 4X) Features, Control and Safety Interlock System. Using 2 Fisher VEE Ball Precision Equal Percentage Mixing Valves with optimum increase or decrease.

5 Techno - Commercial Offer Import Specifications with DISCOUNT No. Item Description Quantity Price / USD B RANSOME MPM 50 C (Modulating Proportional Air Mixer/Blender) - Cont. Graduation of Load and Wobbe instantaneous accuracies. Driven by 2 Fisher precision valves matching pneumatic actuators. Using 2 instead of just 1 DP electronic controllers. No Valve positioners used. Instead, a Ransome designed proprietary mechanical linkage assembly is used with gas VEE Ball valve as Master and air VEE Ball as Slave units. 1st Fisher actuator drives the Master and Slave with precise load modulation. (gas side) 2nd Fisher actuator drives a second Fisher Precision Mixer valve supplying precise amount of air to the Slave VEE Ball for precise Wobbe / instant load following capability. 2 separate electronic DP signals for both Master and Slave VEE Balls are set to both DP Controllers through 2 Transmitters. Because of all the above control process designed features a Standard Turn Down Ratio of 100 to 1 is possible at no extra charge. Both Fisher Actuators are controlled by the 2 DP Controllers through 2 Transducers. Inclusive of 3 pieces Wilkerson Instrument Air Filter System (Impurities, Particulate and Moisture / with a separate Fisher air regulator. Includes 2nd stage LPG vapor regulators with 2nd stage Air Regulator Fisher 99903P to be field installed. 1st stage Air Regulator Fisher 99926PH to be field installed. First Outage Panel Vdc Compressed Air required; Approx. 400 SCFM at send out pressure at Air Receiver at 100 psig no more than 130F Safety Interlocks: Lo Mixed Gas Tempt Limit - Prevent LPG Liquid Spill Over Hi Lo Mixed Gas Pressure Limit Hi Lo Air Pressure Limit

6 Techno - Commercial Offer Import Specifications with DISCOUNT No. Item Description Quantity Price / USD B RANSOME MPM 50 C (Modulating Proportional Air Mixer/Blender) - Cont. Hi Lo LPG Vapor Pressure Limit Hi Air Ratio Limit C Vaporizer Feed Pump (LPG Supply Pump) 1 skid $ 12,275 Model: Blackmer LGL 158 (PS 20 custom) Capacity: 20GPM Electrical: 380V/3ph/50hz Differential Press: 130PSI LPG supply pump Features Pump system is supplied as a complete factory assembled package with pump, motor, and all required piping, valves, and controls mounted on a steel base. Explosion Proof UL Listed Motor, 7.5/5.0HP, 60Hz/50Hz Pressure Switch: ON 120psi OFF 130psi Bypass with check valves/isolating valves Configuration satisfies NFPA standards as a Class I, Division 1, GroupD unit. D Decanting Pump 1 skid $ 10,070 Model: Blackmer LGL2/LGLD2 Capacity: 67GPM Electrical: 380V/3ph/50hz Differential Press: 50PSI Decanting Pump Features Each pump system is supplied as a complete factory assembled package with pump, motor, and all required piping and valves. Explosion Proof UL Listed Motor, 10.0/7.5HP, 60Hz/50Hz Configuration satisfies NFPA standards as a Class I, Division 1, GroupD unit. E Essential Spare Parts Package 1 set $ 3,800

7 Techno - Commercial Offer Import Specifications with DISCOUNT No. Item Description Quantity Price / USD F Packing, Documentation and Freight Charges up to Karachi Sea Port - $ 5,200 TOTAL C/F KARACHI by sea with DISCOUNT - $ 139,970 Notes: 1. All items shall be imported directly from RANSOME MANUFACTURING, USA. 2. Operational Training to be provided at customer/buyer facility in Pakistan. 3. Standard Shipment Time: weeks ex-factory Fresno after receipt of 100% Irrevocable L/C. 4. Payment will be 100% Irrevocable L/C. 5. All financial terms must be satisfied prior to order processing and shipment. 6. Warranty as per vendor terms and conditions. 7. One year local After Sales Support and Service (on-call basis) to be provided by Target Engineering Enterprise.

8 Terms and Conditions 1. Delivery: working weeks ex-factory + sailing time based on LC/Allowable ship date 2. Payment Terms: a. Complete SNG system: 100 % Irrevocable L/C, can be deferred to a period of days. Firm time period to be decided mutually at the time order. b. Local Specifications: Progressive payments after 70 days of equipment delivery under each item head. 3. Validity: Offer is valid for a period of 16 days from date of submission. 4. Once order is confirmed we shall provide: a. Drawing for pump skids. b. System P & ID. 5. All electrical devices integral to the supplied equipment or modular skids and equipment and all intra-skid wiring are included. 6. All other electrical/mechanical systems and equipment will be furnished by the purchaser unless otherwise stated in this quote. 7. Purchaser shall provide any transformation or power conversion equipment required to accommodate line-side power equipment. 8. Variable cost if any occurred will be invoiced after job completion. 9. Confidentiality: All proposal and quotations, (Including rates and terms), reports containing information or data rendered by TARGET Engineering Enterprise must be held in the strictest confidentiality.

9 Target Engineering Enterprise Scope of Work: 1. Supply of SNG LPG Air Mix equipment and necessary accessories as quoted 2. Installation and Commissioning of complete SNG and LPG Storage system 3. Providing System Designs 4. Operational Training on site Client Scope of Work: 1. Power Supply/DB with UPS for SNG system 2. Power supply/electrical connection for works on site 3. Water supply/connection for works on site 4. LPG Feed Stock with necessary approvals from authorities 5. Fire Water Line/Connection up to SNG plant area 6. Constant compressed air supply required 400 SCFM at 100 PSI to SNG System 7. Accommodation of the Project Supervisor and labor team We hope that this proposal meets your requirement. For any concerns or negotiations, feel free to contact the undersigned. Arsalan Mir Executive Director

A versatile gas mixing system for blending LPG and air that is SAFE, RELIABLE, and EASY TO USE

A versatile gas mixing system for blending LPG and air that is SAFE, RELIABLE, and EASY TO USE A versatile gas mixing system for blending LPG and air that is SAFE, RELIABLE, and EASY TO USE A versatile gas mixing system for blending LPG and air that is SAFE, RELIABLE, and EASY TO USE Contents The

More information

hydro-pac, inc. Low-Pressure Gas Compressors 1500 to 6000 PSI

hydro-pac, inc. Low-Pressure Gas Compressors 1500 to 6000 PSI hydro-pac, inc. LX-SERIES Low-Pressure Gas Compressors 1500 to 6000 PSI hydro-pac, inc. LX-SERIES Features Hydro-Pac LX-SERIES Gas Compressors feature: Oil-free non lubricated gas pistons and cylinders

More information

Valve Proving System VDK 200 A S02

Valve Proving System VDK 200 A S02 Valve Proving System VDK 200 A S02 Valve proving system with the following approvals. UL Recognized File # MH17004 CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter

More information

Valve Proving System VDK 200 A S06*

Valve Proving System VDK 200 A S06* Valve Proving System VDK 200 A S06* Valve proving system with the following approvals. UL Recognized File # MH17004 CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter

More information

Inert Air (N2) Systems Manual

Inert Air (N2) Systems Manual INSTRUCTION MANUAL Inert Air (N2) Systems Manual N2-MANUAL 2.10 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. GENERAL INFORMATION Positive pressure nitrogen gas pressurizing

More information

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series Dual Modular Safety Shutoff Valves DMV-D/602 Series DMV-DLE/602 Series Two normally closed safety shutoff valves in one housing; each with the following approvals. UL Recognized UL 429 File # MH16727 CSA

More information

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply 4.1.1 General The primary function of a system for handling fuel oil is to transfer oil from the storage tank to the oil burner at specified conditions

More information

Product Overview A DIVISION OF MARSH BELLOFRAM

Product Overview A DIVISION OF MARSH BELLOFRAM Product Overview P627 & P630 P627 Available with internal relief device - R627 version P627 & P630 - High Flow Regulators The P627 and P630 are spring loaded, direct-operated regulators for both low and

More information

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series Dual Modular Safety Shutoff Valves DMV-D/602 Series DMV-DLE/602 Series Two normally closed safety shutoff valves in one housing; each with the following approvals. UL Recognized UL 429 File # MH16727 CSA

More information

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions L 100 Bubble-Tube Level System Installation, Operation and Maintenance Instructions Figure 1 Contents Section Description Page 1.0 Introduction 2 2.0 Specifications 3 3.0 Installation 3 4.0 Warranty 6

More information

TECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve.

TECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve. Foam 302 a 1. DESCRIPTION (Refer to Figure 1 on page 302 e.) The Viking Low-Flow Foam/Water Proportioning System is a UL Listed and FM Approved system, for use with 3M and Viking brand foam concentrate.

More information

Liquid Level Controllers

Liquid Level Controllers Liquid Level Controllers ALL PUMPS LLC-2Y For both pump up and down control. Variable On/Off set points. NDP-15/20/25/32, DP-10/15 & *NDP-40/50/80 LLC-1 Pump up and down versions available. 6 to 12 differential

More information

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure DMV-D/624L Series DMV-DLE/624L Series Two normally closed automatic shutoff valves in one housing. Valve 2 (V2) incorporates proof

More information

Dual Modular Safety Shutoff Valves with Proof of Closure. DMV-D/622 Series DMV-DLE/622 Series

Dual Modular Safety Shutoff Valves with Proof of Closure. DMV-D/622 Series DMV-DLE/622 Series Dual Modular Safety Shutoff Valves with Proof of Closure DMV-D/622 Series DMV-DLE/622 Series Two normally closed automatic shutoff valves in one housing. Valve 2 (V2) incorporates proof of closure. Each

More information

PGM PREPIPED GAS MANIFOLD

PGM PREPIPED GAS MANIFOLD INSTRUCTIONS PGM PREPIPED GAS MANIFOLD WARNING These instructions are intended for use only by experienced, qualified combustion start-up personnel. Adjustment of this equipment and its components by unqualified

More information

SPECIFICATIONS ATTENTION

SPECIFICATIONS ATTENTION VPS 504 S06 Installation Manual - P/N 80122 - Ed. 01/09 VPS 504 S06 and S05 Valve Proving System Installation Instructions VPS 1 6 Gases Natural gas, air and other inert gases. NOT suitable for butane

More information

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance CVI Valve Line Exceeds the industry s highest standards for reliability and performance Available in the most standard models with the shortest lead times in the industry Exceptional quality every CVI

More information

AIR DRIVEN. Gas Boosters & SYSTEMS. Accepting VISA, MasterCard and American Express

AIR DRIVEN. Gas Boosters & SYSTEMS. Accepting VISA, MasterCard and American Express AIR DRIVEN Gas Boosters & SYSTEMS Accepting VISA, MasterCard and American Express Gas Boosters AIR DRIVEN FROM 30 PSI TO 21,750 PSI MAXIMATOR Maximator gas boosters are an excellent alternative to high

More information

TECHNICAL DATA. than the water inlet pressure to the concentrate

TECHNICAL DATA. than the water inlet pressure to the concentrate Foam102a 1. DESCRIPTION The Viking Low Flow Foam/Water proportioning system, is a UL Listed and FM Approved system, for use with 3M foam concentrates. This system consists of a standard wet pipe sprinkler

More information

SINGLE VALVE WITH LOW-FLOW BYPASS

SINGLE VALVE WITH LOW-FLOW BYPASS CONTROL VALVES Pressure Reducing Valve Sizing Guide Sizing pilot operated reducing valves is not a complicated process. It starts with determining requirements and following these guidelines in valve size

More information

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure DMV-D/624L Series DMV-DLE/624L Series Two normally closed automatic shutoff valves in one housing. Valve 2 (V2) incorporates proof

More information

GAS SUPPLY DESIGN GUIDE

GAS SUPPLY DESIGN GUIDE GAS SUPPLY DESIGN GUIDE Natural Gas, Propane Gas, or Dual Fuel Fired Modulating, Condensing Boilers BENCHMARK Series Gas-Fired Boilers For models: BMK750 to BMK6000 Last Update: 06/20/2014 PR1 06/20/14

More information

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners BULLETIN MT2035-07/05 Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners M/MR Series M411, M511, M611 M420, M520, M620, MR410, MR510, MR610 MR212D, MR212E, MR212G and MR212J (Flanged),

More information

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL Capital Controls Series 71V3000 The Series 71V3000 electrically-heated vaporizer automatically vaporizes and superheats liquid chlorine, sulfur dioxide or ammonia at a rate controlled by the gas feed system.

More information

Dual Modular Safety Shutoff Valve with NEMA 4x Enclosure. DMV-D/604L Series DMV-DLE/604L Series

Dual Modular Safety Shutoff Valve with NEMA 4x Enclosure. DMV-D/604L Series DMV-DLE/604L Series Dual Modular Safety Shutoff Valve with NEMA 4x Enclosure DMV-D/604L Series DMV-DLE/604L Series Two normally closed automatic shutoff valves in one housing; each with the following approvals. UL Listed

More information

Model: 43T. Bermad Pressure Relief Valve

Model: 43T. Bermad Pressure Relief Valve Model: 43T Bermad Pressure Relief Valve Installation Operation Maintenance Manual () Rev.C1_01.08.17 Page 1 of 10 Safety First BERMAD believes that the safety of personnel working with and around our equipment

More information

VB-7323 Series. Application. Features. Applicable Literature. 1/2 to 2 Screwed NPT Three-Way Diverting Valves General Instructions

VB-7323 Series. Application. Features. Applicable Literature. 1/2 to 2 Screwed NPT Three-Way Diverting Valves General Instructions VB-7323 Series 1/2 to 2 Screwed NPT Three-Way Diverting Valves General Instructions Application VB-7323 series three-way diverting valves control hot or chilled water in heating or air conditioning systems.

More information

XDF BURNERS DUAL FUEL EXCESS AIR BURNER FEATURES DESCRIPTION EXCESS AIR OPERATION

XDF BURNERS DUAL FUEL EXCESS AIR BURNER FEATURES DESCRIPTION EXCESS AIR OPERATION DUAL FUEL EXCESS AIR BURNER MODEL: 3610, 3651 Revision: 0 FEATURES Burns all fuel gases or light oils Nozzle mix design for on ratio control or excess air 350% excess air all sizes on gas or oil Turndown

More information

Pressure on Demand. Air Pressure Amplifiers

Pressure on Demand. Air Pressure Amplifiers Pressure on Demand Air Pressure Amplifiers Introduction Haskel air pressure amplifiers offer the most comprehensive range in the industry combining simple principles of operation with rugged construction

More information

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series Dual Modular Safety Shutoff Valves with Two-stage operation DMV-ZRD/602 Series DMV-ZRDLE/602 Series Two normally closed automatic shutoff valves in one housing; each with the following approvals. UL Recognized

More information

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000 Hoffman Specialty Regulators Regulators Pressure and/or Temperature Operated Regulators Series 2000 The Hoffman Specialty Series 2000 consists of main valves, pilot valves, wells and hardware kits. They

More information

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION Install your Blue River Technologies Port-A-Poly mixing system in a clean dry area.

More information

G SPECIFICATION: TITLE: VOLUME: 4 REVISIONS:

G SPECIFICATION: TITLE: VOLUME: 4 REVISIONS: SPECIFICATION: G-2040-7 TITLE: REQUIREMENTS FOR THE INSTALLATION OF GAS BOOSTERS AND BACK PRESSURE/SUCTION PROTECTIVE DEVICES IN VOLUME: 4 REVISIONS: Totally re-written. G-2040-7 Gas Operations Standards

More information

DEPARTMENT OF CHEMICAL ENGINEERING INDIAN INSTITUTE OF TECHNOLOGY MADRAS CHENNAI , INDIA

DEPARTMENT OF CHEMICAL ENGINEERING INDIAN INSTITUTE OF TECHNOLOGY MADRAS CHENNAI , INDIA DEPARTMENT OF CHEMICAL ENGINEERING INDIAN INSTITUTE OF TECHNOLOGY MADRAS CHENNAI 600036, INDIA Ref. No. CHE/17-18/CHE/006/GAIM/RAJN Date: 25 APRIL, 2018 Due date: 9 MAY, 2018 Item: High Pressure Gas Hydrate

More information

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves. Powers Controls RV 201 Pressure Reducing Valves Description Features Product Numbers Dual Pressure PRV Technical Instructions Document No. 155-049P25 RV 201-1 Single Pressure PRV The RV 201 Pressure Reducing

More information

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11 Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11 Two normally closed safety shutoff valves in one housing; each with the following approvals. CSA Certified ANSI Z21.21 CSA 6.5 Marked C/I

More information

Air Operated Hydraulic Pumping Systems to 50,000 psi

Air Operated Hydraulic Pumping Systems to 50,000 psi High Pressure Equipment Air Operated Hydraulic Pumping Systems to 50,000 psi PS-10: 10,000 psi PS-20: 20,000 psi PS-30: 30,000 psi PS-40: 40,000 psi PS-50: 50,000 psi PS-90: 90,000 psi High Pressure air

More information

VB-7213 Series. Application. Features. Applicable Literature. 1/2" to 2" Screwed NPT Stem Up Open, Two-Way Valves General Instructions

VB-7213 Series. Application. Features. Applicable Literature. 1/2 to 2 Screwed NPT Stem Up Open, Two-Way Valves General Instructions VB-7213 Series 1/2" to 2" Screwed NPT Stem Up Open, Two-Way Valves General Instructions Application VB-7213 series single seat, stem up open, two-way valves control water from 20 to 281 F (-7 to 138 C)

More information

Capacities Valve Station, type ICF 15, 20, 25

Capacities Valve Station, type ICF 15, 20, 25 Data sheet Capacities Valve Station, type ICF 15, 20, 25 Based on advanced technology the ICF valve station incorporates several functions in one housing, which can replace a series of conventional mechanical,

More information

Air Amplifiers & SYSTEMS

Air Amplifiers & SYSTEMS Air Amplifiers & SYSTEMS We Accept VISA, MasterCard and American Express Air Amplifiers Point-of-Use Air Solutions Maximator air amplifiers are designed to boost plant air pressure or increase the supply

More information

ISQB1 INTRINSICALLY SAFE ELECTRO-PNEUMATIC CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS HAZARDOUS AREA CLASSIFICATION

ISQB1 INTRINSICALLY SAFE ELECTRO-PNEUMATIC CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS HAZARDOUS AREA CLASSIFICATION PROPORTION AIR ISQB1 INTRINSICALLY SAFE ELECTRO-PNEUMATIC CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS Hazardous area classification Description / identification General specifications Connection

More information

Water Mist Systems Inspection, Testing, and Maintenance of Water Mist Systems

Water Mist Systems Inspection, Testing, and Maintenance of Water Mist Systems Water Mist Systems Inspection, Testing, and Maintenance of Water Mist Systems Name of Property: Address: Phone Number: Inspector: Contract No.: Date: This Report Covers: Monthly Quarterly Annual Other

More information

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18 The Bray Simple Set Max is a flanged pressure independent control (PIC) valve designed for a wide variety of hot water and chilled water control applications. The SSM Series combines high rangeability

More information

Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure. DMV-ZRD/612 Series DMV-ZRDLE/612 Series

Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure. DMV-ZRD/612 Series DMV-ZRDLE/612 Series Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure DMV-ZRD/612 Series DMV-ZRDLE/612 Series Two normally closed automatic shutoff valves in one housing. Valve 1 (V1) incorporates

More information

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series Dual Modular Safety Shutoff Valves with Two-stage operation DMV-ZRD/602 Series DMV-ZRDLE/602 Series Two normally closed automatic shutoff valves in one housing; each with the following approvals. UL Recognized

More information

MEDICAL EQUIPMENT CATALOG

MEDICAL EQUIPMENT CATALOG THE MOST TRUSTED MEDICAL EQUIPMENT IN NORTH AMERICA MEDICAL EQUIPMENT CATALOG Total Components Including Bulk Oxygen Supply, Back up and Delivery Equipment Designs for High Pressure, Liquid or Bulk Applications

More information

Sullair Air Systems. *Assessment of the market for compressed air efficiency services. Technical report, U.S. Department of Energy, June 2001

Sullair Air Systems. *Assessment of the market for compressed air efficiency services. Technical report, U.S. Department of Energy, June 2001 Sullair Air Systems The three most expensive components in operating a compressed air system are: inadequate, inefficient controls that waste energy; lost production due to an improperly maintained system;

More information

VB-7212 Series. Application. Features. Applicable Literature. 5/8" O.D., 45 SAE Flared Stem Up Open, Two-Way Valves General Instructions

VB-7212 Series. Application. Features. Applicable Literature. 5/8 O.D., 45 SAE Flared Stem Up Open, Two-Way Valves General Instructions VB-7212 Series 5/8" O.D., 45 SAE Flared Stem Up Open, Two-Way Valves General Instructions Application VB-7212 series single seat, stem up open, two-way valves control water from 20 to 281 F (-7 to 138

More information

CAPITAL CONTROLS SERIES NXT3000

CAPITAL CONTROLS SERIES NXT3000 CAPITAL CONTROLS SERIES NXT3000 Modular design gas feed system with self contained automatic switchover capability. The Series NXT3000 Gas Feed System is a family of vacuumoperated, solution-feed gas dispensing

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 333a 1. Description Viking supervised Surefire Preaction Systems Utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated Viking G-3000P Valve comes complete

More information

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11 Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11 Two normally closed safety shutoff valves in one housing; each with the following approvals. CSA Certified ANSI Z21.21 CSA 6.5 Marked C/I

More information

BUBBLER CONTROL SYSTEM

BUBBLER CONTROL SYSTEM BUBBLER CONTROL SYSTEM Description: The HDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air

More information

Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure DMV-ZRD/612 Series DMV-ZRDLE/612 Series

Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure DMV-ZRD/612 Series DMV-ZRDLE/612 Series Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure DMV-ZRD/612 Series DMV-ZRDLE/612 Series Two normally closed automatic shutoff valves in one housing. Valve 1 (V1) incorporates

More information

Dual Modular Safety Shutoff Valves with NEMA 4x Enclosure DMV-D 704/604 DMV-DLE 704/604

Dual Modular Safety Shutoff Valves with NEMA 4x Enclosure DMV-D 704/604 DMV-DLE 704/604 Dual Modular Safety Shutoff Valves with NEMA 4x Enclosure DMV-D 704/604 DMV-DLE 704/604 Two normally closed safety shutoff valves in one housing; each with the following approval. CSA Certified ANSI Z21.21

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE April 9, 2009 Preaction 326a 1. DESCRIPTION Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilizing the Viking G-4000P Deluge Valve. The small profi le, lightweight,

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 347a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated

More information

NGN Series nitrogen generator

NGN Series nitrogen generator NGN Series 8-64 nitrogen generator Applications how it works RK series 5-40 F Blanketing of Chemicals and Pharmaceuticals Gas Assisted Injection Moulding (GAIM) Laser Cutting Food Heat Treament of Ferrous

More information

Memo. Shelley Cohen. From: Bill Dickson CC: Date: February 5, 2015 Re: Editorial Oil & Gas News

Memo. Shelley Cohen. From: Bill Dickson CC: Date: February 5, 2015 Re: Editorial Oil & Gas News Memo To: Shelley Cohen From: Bill Dickson CC: Date: February 5, 2015 Re: Editorial Oil & Gas News Tag Line: Bauer Compressors, Inc. Delivers a Custom Solution Copy: Bauer has manufactured and provided

More information

VRD Series VRD40.xxxUx Double Valves for use with SKP... electro-hydraulic actuators

VRD Series VRD40.xxxUx Double Valves for use with SKP... electro-hydraulic actuators VRD Series VRD40.xxxUx Double Valves for use with SKP... electro-hydraulic actuators Document No. 7649 VRD40.xxxUx ISO 9001 and 14001 REGISTERED FIRM Only with series SKPxx.xxxUx actuators Description

More information

The Discussion of this exercise covers the following points:

The Discussion of this exercise covers the following points: Exercise 5-3 Wet Reference Leg EXERCISE OBJECTIVE Learn to measure the level in a vessel using a wet reference leg. DISCUSSION OUTLINE The Discussion of this exercise covers the following points: Measuring

More information

Bermad Pressure Reducing. Model: 42T

Bermad Pressure Reducing. Model: 42T Bermad Pressure Reducing Pilot Operated Pressure Control Valve Model: 42T Installation Operation Maintenance Manual (IOM) REV. 27.7.17 Page 1 of 12 Safety First BERMAD believes that the safety of personnel

More information

Product Overview A DIVISION OF MARSH BELLOFRAM

Product Overview A DIVISION OF MARSH BELLOFRAM Product Overview P627 & P630 P627 P627 & P630 - High Flow Regulators The P627 and P630 are spring loaded, direct-operated regulators for both low and high pressure applications in the oil and gas industries.

More information

VB-7211 Series. Application. Features. Applicable Literature. 1/2" to 1-1/4" Union End NPT Stem Up Open, Two-Way Valves General Instructions

VB-7211 Series. Application. Features. Applicable Literature. 1/2 to 1-1/4 Union End NPT Stem Up Open, Two-Way Valves General Instructions TAC 1354 Clifford Avenue P. O. Box 2940 Loves Park, IL 61132-2940 www.tac.com VB-7211 Series 1/2" to 1-1/4" Union End NPT Stem Up Open, Two-Way Valves General Instructions Application VB-7211 series stem

More information

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL I-867-4T 867-4T Pressure Reducing Valve HANG THESE INSTRUCTIONS ON THE INSTALLED VALVE FOR FUTURE REFERENCE WARNING Read and understand all instructions

More information

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability. Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability. The Series NXT3000 Gas Feed System is a family of vacuum-operated, solution-feed gas

More information

SV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT. SV/614 Series SV-DLE/614 Series

SV - Safety Shutoff Valve with Proof of Closure 1/2 NPT - 2 NPT. SV/614 Series SV-DLE/614 Series SV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT SV/614 Series SV-DLE/614 Series Normally closed automatic shutoff valve with proof of closure and the following approvals. CSA Certified

More information

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company CIF A Tyco International Company 1 Foam Concentrate CIF 3% AFFF -UL Listed -UL Canada Listed 6% AFFF 6 parts AFFF concentrate to 94 parts water -UL Listed- Foam Liquid -UL Canada Listed 3% FLUOROPROTEIN

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 348a 1. Description Viking supervised Surefire Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated Viking G-6000P Valve comes complete

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 331a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated

More information

RadKits (Piping Packages)

RadKits (Piping Packages) Product nformation Models RadKit Option Overview here are six (6) RadKit options available for Price Active & Passive Beam Products. hey vary in features according to application requirements, from a basic

More information

Becker Precision Equipment

Becker Precision Equipment Becker Precision Equipment VRP-CH Series Valve Regulation Pilot For Use with Double-Acting Operated Actuators Description The Becker Model VRP-CH Double-Acting Pilot provides pressure control when utilized

More information

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC 05 Elster GmbH Edition 0.5 Translation from the German 058 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Linear flow control VFC Linear flow control with actuator IFC Contents

More information

Becker Precision Equipment

Becker Precision Equipment Becker Precision Equipment VRP-B-CH Series Valve Regulation Pilot VRP-B-CH Valve Regulator Pilot Provides Low-Bleed Pressure Control When Combined with Double-Acting Pneumatic Control Valve Actuators Description

More information

Section GAS CHLORINATION SYSTEM

Section GAS CHLORINATION SYSTEM PART 1 GENERAL 1.01 SUMMARY Section 11260 This Section includes the furnishing and subsequent installation, complete and in place, of a functioning gas chlorination disinfection system for water as shown

More information

CS Controlled Dissolved Gas assembly with optional CS Air Aspirator assembly. Installation and Operation information

CS Controlled Dissolved Gas assembly with optional CS Air Aspirator assembly. Installation and Operation information CS-425-01 Controlled Dissolved Gas assembly with optional CS-603-01 Air Aspirator assembly Installation and Operation information Serial # CS-XXX Date of shipment:, 2005 Shipped to: Purchase order #: xxxxxxx

More information

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Standard Operating and Maintenance Instructions for Pumping System Model PS-90 Standard Operating and Maintenance Instructions for Pumping System Model PS-90 High Pressure Equipment Company 2955 West 17th Street, Suite 6 PO Box 8248 Erie, PA 16505 USA 814-838-2028 (phone) 814-838-6075

More information

Schedule of Requirements THERMODYNAMICS LABORATORY- CHEMICAL ENGINEERING DEPARTMENT

Schedule of Requirements THERMODYNAMICS LABORATORY- CHEMICAL ENGINEERING DEPARTMENT S. No 1 Description Calorimeter The Unit should be designed for the accurate determination of the calorific value of liquid and solid hydrocarbons and other fuels. Specifications: A temperature-controlled

More information

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B September 16, 2013 Trimpac 250a 1. DESCRIPTION DEsCRIPTIoN is a factory assembled trim package for a ed an electric/pneumatic release module in a metal enclosure. The standard trim normally required on

More information

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function Technical Instructions Document No. 155-752 SKP25 U.. Description Only when assembled to Series VG Gas valves SKP25

More information

GP1 & GP2. Electropneumatic Regulators FOR PRESSURE CONTROL TO 1,000 PSI

GP1 & GP2. Electropneumatic Regulators FOR PRESSURE CONTROL TO 1,000 PSI GP1 & GP2 Electropneumatic Regulators FOR PRESSURE CONTROL TO 1, PSI GP1 & GP2 Functional Description The GP series control valve is an electronic pressure regulator designed to precisely control the pressure

More information

Wet pipe low flow foam/water system

Wet pipe low flow foam/water system December 6, 2010 Foam 14a 1. The Viking Low Flow Foam/Water proportioning system, is a UL Listed and FM Approved system, for use with Viking supplied foam concentrates. This system consists of a standard

More information

Dual Modular Safety Shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634

Dual Modular Safety Shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634 Dual Modular Safety Shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634 Two normally closed automatic shutoff valves in one housing.

More information

Model 106 DPI "Micro-switch" Installation and Operating Instructions

Model 106 DPI Micro-switch Installation and Operating Instructions Mid-West Instrument Model 106 DPI "Micro-switch" Installation and Operating Instructions BULLETIN NO. IM116DPImicro/09A Replaces --- INSPECTION Before installation carefully check the Model Number on each

More information

OPERATION MANUAL NTF-15

OPERATION MANUAL NTF-15 OPERATION MANUAL NTF-15 Nitrogen Tire Filling Valve Stem Caps (Qty=200) Order P/N 436075 RTI Technologies, Inc 10 Innovation Drive York, PA 17402 800-468-2321 www.rtitech.com 035-81235-00 (Rev B) TABLE

More information

Gas Pressure Regulator HON 200

Gas Pressure Regulator HON 200 Product information serving the gas industry worldwide Applications, characteristics, technical data Application Gas supply to municipal, industrial and individual consumers Regulator for low-load rails

More information

Flex-Kleen CT Series Pulse-Jet Dust Collectors For high pressure/high vacuum applications

Flex-Kleen CT Series Pulse-Jet Dust Collectors For high pressure/high vacuum applications Bulletin CT Flex-Kleen CT Series Pulse-Jet Dust Collectors For high pressure/high vacuum applications CT (Circular Tank) COLLECTORS... especially effective for dusting problems in drying, grinding and

More information

M-System s I/P and P/I Transducers

M-System s I/P and P/I Transducers roduct introduction and application examples 6-0023 2017-12 EC-Z654 M-System s / and s Rev. 0 01 500523 Two-wire models available with no power supply required ower Chemical plants plants Actual Size M-System

More information

TECHNICAL DATA. Page 1 of 12

TECHNICAL DATA. Page 1 of 12 Page 1 of 12 1. DESCRIPTION The Viking Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking Model H or J Flow Control

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Installation, Operation, and Maintenance Manual Welker Dehydration Assembly Model DA-1 Drawing No.: AD079CO, AD285CR Manual No.: IOM-018 The information in this manual has been carefully checked for accuracy

More information

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators Technical Instructions Document No. 155-51P5 VG August 11, 005 GAS009R1 VGG VGD0 VGD0 Description Only when assembled to SKP

More information

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC 07 Elster GmbH Edition 06.7 Translation from the German 058 D GB F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Linear flow control VFC Linear flow control with actuator IFC

More information

PNEUMATIC ACTUATED INDUSTRIAL VALVES SERIES:

PNEUMATIC ACTUATED INDUSTRIAL VALVES SERIES: PRODUCT SPECIFICATION March 05 PNEUMATIC ACTUATED INDUSTRIAL VALVES SERIES: 1800 SIZES 2-1/2 to 12 INCHES Heavy Globe Control Valves Two-Way and Three-Way, Reciprocating Iron, Steel, or Stainless Steel

More information

Pressure regulator with solenoid valve VAD Air/gas ratio control with solenoid valve VAG

Pressure regulator with solenoid valve VAD Air/gas ratio control with solenoid valve VAG C US Pressure regulator with solenoid valve Air/gas ratio control with solenoid valve All-purpose servo regulator for gaseous media with integrated safety valve Suitable for a max. inlet pressure of 500

More information

RCD - Ultra-Rugged Differential Pressure Flowmeter

RCD - Ultra-Rugged Differential Pressure Flowmeter 0.15-1 to 85-600 GPM Liquids 2.5-25 to 300-1700 SCFM Gases 1/2 to 3 Line Sizes Bronze or 316-Ti Stainless Steel Mechanical Indicator, Digital Indicator, Transmitters and Switches Available Custom Calibrations

More information

Fisher DVI Desuperheater Venturi Inline

Fisher DVI Desuperheater Venturi Inline Instruction Manual DVI Desuperheater Fisher DVI Desuperheater Venturi Inline Contents Introduction... 1 Scope of Manual... 1 Description... 1 Principle of Operation... 2 Installation... 3 Operating Instructions...

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S Preaction 346a 1. Description The 6 Model G-6000P Electric Release Preaction System Riser Assembly can be used as a Single Interlock Preaction System with Electric Release, or as a Double Interlock Preaction

More information

G REQUIREMENTS FOR THE INSTALLATION OF GAS BOOSTERS, MICROTURBINES AND ASSOCIATED SYSTEM PROTECTIVE DEVICES

G REQUIREMENTS FOR THE INSTALLATION OF GAS BOOSTERS, MICROTURBINES AND ASSOCIATED SYSTEM PROTECTIVE DEVICES LAST REVIEW DATE: REVIEW CYCLE: 6/22/11 5 Years SPECIFICATION: TITLE: VOLUME: G-2040-9 REQUIREMENTS FOR THE INSTALLATION OF GAS BOOSTERS, MICROTURBINES AND ASSOCIATED 4 and Gas Blue Book REVISIONS: (See

More information

Work Horses of the Breathing Air Industry

Work Horses of the Breathing Air Industry High Pressure Breathing Air Equipment Work Horses of the Breathing Air Industry Pegasus Compressor The Pegasus vertically enclosed compressor is a full-featured system that incorporates the latest technology

More information

BHEL/Trichy-14 CCDP SYSTEM DESCRIPTION FOR DOME VALVE:

BHEL/Trichy-14 CCDP SYSTEM DESCRIPTION FOR DOME VALVE: BHEL/Trichy-14 CCDP SYSTEM DESCRIPTION FOR DOME VALVE: The Dome Valve is a pressure tight, power operated Valve for application in Material Inlet / Vessel Discharge / Line Change over etc. The Valves should

More information

VBS-9263 Series. Application. Features. Applicable Literature

VBS-9263 Series. Application. Features. Applicable Literature TAC 1354 Clifford Avenue P. O. Box 2940 Loves Park, IL 61132-2940 www.tac.com VBS-9263 Series 1/2" and 3/4" Screwed NPT 316 Stainless Steel Stem Up Closed, Two-Way Valves General Instructions Application

More information